WorldWideScience

Sample records for safety false-positive reactions

  1. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  2. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  3. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  4. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  5. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  6. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  7. False Positive and False Negative Effects on Network Attacks

    Science.gov (United States)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  8. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  9. Use of the false discovery rate for evaluating clinical safety data.

    Science.gov (United States)

    Mehrotra, Devan V; Heyse, Joseph F

    2004-06-01

    Clinical adverse experience (AE) data are routinely evaluated using between group P values for every AE encountered within each of several body systems. If the P values are reported and interpreted without multiplicity considerations, there is a potential for an excess of false positive findings. Procedures based on confidence interval estimates of treatment effects have the same potential for false positive findings as P value methods. Excess false positive findings can needlessly complicate the safety profile of a safe drug or vaccine. Accordingly, we propose a novel method for addressing multiplicity in the evaluation of adverse experience data arising in clinical trial settings. The method involves a two-step application of adjusted P values based on the Benjamini and Hochberg false discovery rate (FDR). Data from three moderate to large vaccine trials are used to illustrate our proposed 'Double FDR' approach, and to reinforce the potential impact of failing to account for multiplicity. This work was in collaboration with the late Professor John W. Tukey who coined the term 'Double FDR'.

  10. Consequences of a false-positive mammography result

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Bæksted, Christina; Vejborg, Ilse

    2016-01-01

    group used anxiolytic and antidepressant drugs. There was no difference in use of beta blockers. Hormone therapy was used more frequently by the false-positive, 36.6% versus 28.7%. The proportion of women using anxiolytic and antidepressant drugs increased with 19% from the before to the after period...... in the false-positive group, and with 16% in the normal group, resulting in an RRR of 1.02 (95% CI 0.92-1.14). RRR was 1.03 for beta blockers, 0.97 for hormone therapy. Conclusion(s): Drugs used to mitigate mood disorders were used more frequently by women with false-positive than by women with normal......Background: Previous research showed women experiencing false-positive mammograms to have greater anxiety about breast cancer than women with normal mammograms. To elucidate psychological effects of false-positive mammograms, we studied impact on drug intake.  Methods: We calculated the ratio...

  11. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  12. High prevalence of human anti-bovine IgG antibodies as the major cause of false positive reactions in two-site immunoassays based on monoclonal antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Koch, Claus; Jensen, Charlotte H

    2004-01-01

    were purified by protein G affinity chromatography from culture supernatant containing 10% (v/v) fetal calf serum (FCS). Human anti-animal IgG (bovine, mouse, horse, and swine) antibodies and human anti-bovine serum albumin antibodies were measured using an ELISA design, with direct bridging...... of the solid phase and biotinylated antigens. The false positive reactions were abolished by addition of 1% (v/v) bovine serum to the dilution buffer (DB). Human anti-bovine IgG antibodies (HABIA) were detected in 99 out of 104 sera from blood donors (50 females; 54 males). HABIA levels in male sera (n = 54......) were positively correlated to the false positive signals in the PP14 ELISA (r = 0.923; p detected in the donor sera, but levels and frequencies were lower compared to that of HABIA. Furthermore, HABIA were...

  13. The problem of false positives and false negatives in violent video game experiments.

    Science.gov (United States)

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Characterisation of false-positive observations in botanical surveys

    Directory of Open Access Journals (Sweden)

    Quentin J. Groom

    2017-05-01

    Full Text Available Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify

  15. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    Science.gov (United States)

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the

  16. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  17. False-positive 111In-pentetreotide Uptake in Gastritis

    International Nuclear Information System (INIS)

    Usmani, Sharjeel; Alshammari, Alshaima

    2013-01-01

    111 In-pentetreotide [ 111 In-octreoscan] is the most widely used radiolabeled somatostatin analog for evaluating neuroendocrine tumor overexpression of somatostatin receptors. False-positives studies of somatostatin receptor scintigraphy have been reported and often the cause is unexplained but assumed to be due to high number of somatostatin receptors in other pathologies. Causes of false-positives include visualization of the gallbladder, nasal mucosa and pulmonary hilar areas in respiratory infections, thyroid abnormalities, accessory spleens, recent Cerebrovascular accidents (CVA's) and activity at the site of a recent surgical incision. In infection or inflammation the cause of false-positive uptake is probably the result of tracer binding by somatostatin receptors on the inflammatory leukocytes. In this case report, we report, a 44-year-old male patient with false-positive 111 In-pentetreotide uptake due to gastritis

  18. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  19. False-positive results in pharmacoepidemiology and pharmacovigilance.

    Science.gov (United States)

    Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine

    2017-09-01

    False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  20. An investigation of false positive dosimetry results

    International Nuclear Information System (INIS)

    Lewandowski, M.A.; Davis, S.A.; Goff, T.E.; Wu, C.F.

    1996-01-01

    The Waste Isolation Pilot Plant (WIPP) is a facility designed for the demonstration of the safe disposal of transuranic waste. Currently, the radiation source term is confined to sealed calibration and check sources since WIPP has not received waste for disposal. For several years the WIPP Dosimetry Group has operated a Harshaw Model 8800C reader to analyze Harshaw 8801-7776 thermoluminescent cards (3 TLD-700 and 1 TLD-600) with 8805 holder. The frequency of false positive results for quarterly dosimeter exchanges is higher than desired by the Dosimetry Group management. Initial observations suggested that exposure to intense ambient sunlight may be responsible for the majority of the false positive readings for element 3. A study was designed to investigate the possibility of light leaking through the holder and inducing a signal in element 3. This paper discusses the methods and results obtained, with special emphasis placed on recommendations to reduce the frequency of light-induced false positive readings

  1. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    Science.gov (United States)

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  2. Risk of breast cancer after false-positive results in mammographic screening

    DEFF Research Database (Denmark)

    Roman, Marta; Castells, Xavier; Hofvind, Solveig

    2016-01-01

    risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50–69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1......Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level.......4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93–2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77–1.96), whereas those who tested false-positive at third screening had a RR...

  3. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  4. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  5. Risk of breast cancer after false-positive results in mammographic screening.

    Science.gov (United States)

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  7. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    NARCIS (Netherlands)

    Wolf, M.; Kurvers, R.H.J.M.; Ward, A.J.W.; Krause, S.; Krause, J.

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives;

  8. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  10. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  11. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    Science.gov (United States)

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  12. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  13. Psychological effects of false-positive results in expanded newborn screening in China.

    Directory of Open Access Journals (Sweden)

    Wen-Jun Tu

    Full Text Available OBJECTIVES: As more families participate expanded newborn screening for metabolic disorders in China, the overall number of false positives increases. Our goal was to assess the potential impact on parental stress, perceptions of the child's health, and family relationships. METHODS: Parents of 49 infants with false-positive screening results for metabolic disorders in the expanded newborn screening panel were compared with parents of 42 children with normal screening results. Parents first completed structured interview using likert scales, closed and open questions. Parents also completed the parenting stress index. RESULTS: A total of 88 mothers and 41 fathers were interviewed. More mothers in the false-positive group reported that their children required extra parental care (21%, compared with 5% of mothers in the normal-screened group (P<0.001. 39% of mothers in the false-positive group reported that they worry about their child's future development, compared with 10% of mothers in the normal-screened group (P<0.001. Fathers in the false-positive group did not differ from fathers in the normal-screened group in reporting worry about their child's extra care requirements, and their child's future development. Children with false-positive results compared with children with normal results were triple as likely to experience hospitalization (27%vs 9%, respectively; P<0.001. CONCLUSIONS: The results showing false-positive screening results may affect parental stress and the parent-child relationship. Parental stress and anxiety can be reduced with improved education and communication to parents about false-positive results.

  14. Epidemiology, public health, and the rhetoric of false positives

    DEFF Research Database (Denmark)

    Blair, Aaron; Saracci, Rodolfo; Vineis, Paolo

    2009-01-01

    BACKGROUND: As an observational science, epidemiology is regarded by some researchers as inherently flawed and open to false results. In a recent paper, Boffetta et al. [Boffetta P, McLaughlin JK, LaVecchia C, Tarone RE, Lipworth L, Blot WJ. False-positive results in cancer epidemiology: a plea f...

  15. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  16. Diagnostic Invasiveness and Psychosocial Consequences of False-Positive Mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert Dirk; Brodersen, John

    2015-01-01

    PURPOSE: We undertook a study to assess whether women with false-positivemammography have worse psychosocial consequences if managed with aworkup that involves a biopsy (invasive group) than if managed with only additional imaging (noninvasive group). METHODS: We performed subgroup analysis...... of a cohort study of 454 womenwith abnormal screening mammography and 908 matched control women withnormal results. Using a condition-specific questionnaire (Consequences of Screening in Breast Cancer), we assessed 12 psychosocial consequences at 5 time points (0, 1, 6, 18, and 36 months after final diagnosis......) and compared the 2 groups of women with false-positives (invasive and noninvasive management groups). RESULTS: Among the 252 women with false-positive mammography eligible forthis study, psychosocial consequences were similar for those managed invasivelyand those managed noninvasively during the 36 months...

  17. Addressing False Positives in Early Reading Assessment Using Intervention Response Data

    Science.gov (United States)

    McAlenney, Athena Lentini; Coyne, Michael D.

    2015-01-01

    The current study examined a solution to high false positive reading risk classification rates in early kindergarten by investigating a method of identifying students with possible false positive risk classifications and returning them to general classroom instruction. Researchers assessed kindergarten students (N = 105) identified as at risk who…

  18. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  19. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  20. Detecting false positive sequence homology: a machine learning approach.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  1. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  2. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University Hospital, Daegu (Korea, Republic of); Seo, Ji Hyoung [Inje University Haeundae Paik Hospital, Busan (Korea, Republic of)

    2010-12-15

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  3. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae; Seo, Ji Hyoung

    2010-01-01

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  4. Positive events protect children from causal false memories for scripted events.

    Science.gov (United States)

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  5. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    Science.gov (United States)

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  7. Look Again: An Investigation of False Positive Detections in Combat Models

    National Research Council Canada - National Science Library

    Wainwright, Ryan K

    2008-01-01

    .... Existing combat models tend to overlook or downplay false positive detections. Signal Detection Theory provides the framework for analysis of an observer's hits, misses, correct rejections, and false alarms...

  8. Categorizing Mistaken False Positives in Regulation of Human and Environmental Health

    DEFF Research Database (Denmark)

    Hansen, Steffen Foss; Krayer von Krauss, Martin Paul; Tickner, J.A.

    2007-01-01

    One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general......," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only...... four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent...

  9. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  10. Positive organizational behavior and safety in the offshore oil industry: Exploring the determinants of positive safety climate.

    Science.gov (United States)

    Hystad, Sigurd W; Bartone, Paul T; Eid, Jarle

    2014-01-01

    Much research has now documented the substantial influence of safety climate on a range of important outcomes in safety critical organizations, but there has been scant attention to the question of what factors might be responsible for positive or negative safety climate. The present paper draws from positive organizational behavior theory to test workplace and individual factors that may affect safety climate. Specifically, we explore the potential influence of authentic leadership style and psychological capital on safety climate and risk outcomes. Across two samples of offshore oil-workers and seafarers working on oil platform supply ships, structural equation modeling yielded results that support a model in which authentic leadership exerts a direct effect on safety climate, as well as an indirect effect via psychological capital. This study shows the importance of leadership qualities as well as psychological factors in shaping a positive work safety climate and lowering the risk of accidents.

  11. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  13. THE XO PLANETARY SURVEY PROJECT: ASTROPHYSICAL FALSE POSITIVES

    International Nuclear Information System (INIS)

    Poleski, Radosaw; McCullough, Peter R.; Valenti, Jeff A.; Burke, Christopher J.; Machalek, Pavel; Janes, Kenneth

    2010-01-01

    Searches for planetary transits find many astrophysical false positives as a by-product. There are four main types analyzed in the literature: a grazing-incidence eclipsing binary (EB) star, an EB star with a small radius companion star, a blend of one or more stars with an unrelated EB star, and a physical triple star system. We present a list of 69 astrophysical false positives that had been identified as candidates of transiting planets of the on-going XO survey. This list may be useful in order to avoid redundant observation and characterization of these particular candidates that have been independently identified by other wide-field searches for transiting planets. The list may be useful for those modeling the yield of the XO survey and surveys similar to it. Subsequent observations of some of the listed stars may improve mass-radius relations, especially for low-mass stars. From the candidates exhibiting eclipses, we report three new spectroscopic double-line binaries and give mass function estimations for 15 single-line spectroscopic binaries.

  14. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  15. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  16. Positive organizational behavior and safety in the offshore oil industry: Exploring the determinants of positive safety climate

    Science.gov (United States)

    Hystad, Sigurd W.; Bartone, Paul T.; Eid, Jarle

    2013-01-01

    Much research has now documented the substantial influence of safety climate on a range of important outcomes in safety critical organizations, but there has been scant attention to the question of what factors might be responsible for positive or negative safety climate. The present paper draws from positive organizational behavior theory to test workplace and individual factors that may affect safety climate. Specifically, we explore the potential influence of authentic leadership style and psychological capital on safety climate and risk outcomes. Across two samples of offshore oil-workers and seafarers working on oil platform supply ships, structural equation modeling yielded results that support a model in which authentic leadership exerts a direct effect on safety climate, as well as an indirect effect via psychological capital. This study shows the importance of leadership qualities as well as psychological factors in shaping a positive work safety climate and lowering the risk of accidents. PMID:24454524

  17. Memory for media: investigation of false memories for negatively and positively charged public events.

    Science.gov (United States)

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  18. False positive reduction in protein-protein interaction predictions using gene ontology annotations

    Directory of Open Access Journals (Sweden)

    Lin Yen-Han

    2007-07-01

    Full Text Available Abstract Background Many crucial cellular operations such as metabolism, signalling, and regulations are based on protein-protein interactions. However, the lack of robust protein-protein interaction information is a challenge. One reason for the lack of solid protein-protein interaction information is poor agreement between experimental findings and computational sets that, in turn, comes from huge false positive predictions in computational approaches. Reduction of false positive predictions and enhancing true positive fraction of computationally predicted protein-protein interaction datasets based on highly confident experimental results has not been adequately investigated. Results Gene Ontology (GO annotations were used to reduce false positive protein-protein interactions (PPI pairs resulting from computational predictions. Using experimentally obtained PPI pairs as a training dataset, eight top-ranking keywords were extracted from GO molecular function annotations. The sensitivity of these keywords is 64.21% in the yeast experimental dataset and 80.83% in the worm experimental dataset. The specificities, a measure of recovery power, of these keywords applied to four predicted PPI datasets for each studied organisms, are 48.32% and 46.49% (by average of four datasets in yeast and worm, respectively. Based on eight top-ranking keywords and co-localization of interacting proteins a set of two knowledge rules were deduced and applied to remove false positive protein pairs. The 'strength', a measure of improvement provided by the rules was defined based on the signal-to-noise ratio and implemented to measure the applicability of knowledge rules applying to the predicted PPI datasets. Depending on the employed PPI-predicting methods, the strength varies between two and ten-fold of randomly removing protein pairs from the datasets. Conclusion Gene Ontology annotations along with the deduced knowledge rules could be implemented to partially

  19. Image Watermarking Scheme for Specifying False Positive Probability and Bit-pattern Embedding

    Science.gov (United States)

    Sayama, Kohei; Nakamoto, Masayoshi; Muneyasu, Mitsuji; Ohno, Shuichi

    This paper treats a discrete wavelet transform(DWT)-based image watermarking with considering the false positive probability and bit-pattern embedding. We propose an iterative embedding algorithm of watermarking signals which are K sets pseudo-random numbers generated by a secret key. In the detection, K correlations between the watermarked DWT coefficients and watermark signals are computed by using the secret key. L correlations are made available for the judgment of the watermark presence with specified false positive probability, and the other K-L correlations are corresponding to the bit-pattern signal. In the experiment, we show the detection results with specified false positive probability and the bit-pattern recovery, and the comparison of the proposed method against JPEG compression, scaling down and cropping.

  20. Algorithm of reducing the false positives in IDS based on correlation Analysis

    Science.gov (United States)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  1. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  2. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  3. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  4. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    Science.gov (United States)

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  5. APHRODITE: an Anomaly-based Architecture for False Positive Reduction

    NARCIS (Netherlands)

    Bolzoni, D.; Etalle, Sandro

    We present APHRODITE, an architecture designed to reduce false positives in network intrusion detection systems. APHRODITE works by detecting anomalies in the output traffic, and by correlating them with the alerts raised by the NIDS working on the input traffic. Benchmarks show a substantial

  6. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  7. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  8. Analyzing false positives of four questions in the Force Concept Inventory

    Science.gov (United States)

    Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-06-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.

  9. False positive paediatric labelled white blood cell study

    International Nuclear Information System (INIS)

    Beveridge, N.; Bennett, E.; Thomas, P.

    2002-01-01

    Full text: An eight-month-old female presented for a technetium labelled white blood cell study (LWBC) to exclude an intra-abdominal abscess. Born premature, the child had surgery to repair a perforated bowel and had repeated presentations with diarrhoea, fevers, a tender right upper quadrant and a raised leucocyte count. Multiple imaging modalities failed to demonstrate recurrent bowel perforation, ischaemia or an intra-abdominal mass. A LWBC study was performed with whole body imaging at 1 and 5 hours post re-injection of the radiolabelled blood. No abnormal uptake was visualised in the abdomen but abnormal white cell accumulation was noted in the right hind foot and the length of the right lower leg. This activity appeared to lie along the course of the right tibia. Plain X-ray demonstrated no evidence of tibial osteomyelitis. Concern that the LWBC may be falsely negative in a patient on antibiotics, a gallium scan was immediately performed to re-examine the abdomen. The whole body gallium images demonstrated normal physiological uptake in the abdomen and no evidence of infection in the right leg. The patient had no clinical features to support right leg pathology. The abnormal LWBC localisation in the right lower leg/foot was therefore falsely positive. The most likely explanation is increased activation of the autologous LWBC by 'rough' handling during difficult venesection and re-injection through small veins and needles/cannulas. The slow flow through the veins draining the foot injection site would contribute to margination in these vessel walls. This is a potential cause for false positive LWBC studies- with significant implications for patient care. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. False positive seroreactivity to brucellosis in tuberculosis patients: a prevalence study

    Directory of Open Access Journals (Sweden)

    Mojtaba Varshochi

    2011-03-01

    Full Text Available Mojtaba Varshochi1,2, Jafar Majidi2, Marjan Amini1, Kamyar Ghabili3, Mohammadali M Shoja31Department of Infectious Disease, Tabriz University of Medical Sciences, Tabriz, Iran; 2Infectious Disease and Tropical Medicine Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; 3Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: The rising worldwide incidence of tuberculosis (TB increases the demand for knowledge about its potential seroreactivity with other microbial agents. A few reports and the authors’ experiences indicate that tuberculosis may result in a false-positive brucellosis serology. This may cause a diagnostic challenge because of the close clinical resemblance of these two infections.Objective: The aim of the present prevalence study was to elucidate brucellosis seroreactivity in patients with active TB.Methods: Ninety-eight patients with newly diagnosed and active TB were studied using an enzyme-linked immunosorbent assay (ELISA and Wright’s and Coombs–Wright’s tests. Seventy-five healthy individuals were used as controls. The patients showed signs of recovery after starting a standard anti-TB regimen and had no clinical evidence of brucellosis at a subsequent 6-month follow-up. The data were analyzed statistically by Fisher’s exact test using SPSS 11.0.Results: We found that 9.2% of TB patients versus 1.3% of healthy controls had positive results on the anti-Brucella IgG ELISA (P = 0.04. Five TB patients were found to have agglutination on Wright’s tests, while none of the controls showed agglutination.Conclusion: Active TB patients may have some seroreactivity with Brucella antigens, and Brucella IgG ELISA may give a false positive in these patients. Clinicians should consider false positive brucellosis seroreactivity in patients with active TB.Keywords: false positive serology, ELISA, diagnosis

  11. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  12. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Directory of Open Access Journals (Sweden)

    Yamaguchi Rin

    2012-05-01

    Full Text Available Abstract Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases, to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6% cases were benign, including mastopathy (fibrocystic disease in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9% cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC being significantly more frequent (49.5% than papillotubular growing type (Papi-tub (P P = 0.0001 and ductal carcinoma in situ (DCIS (P = 0.0001. Among 458 indeterminate cases, 54/139 (38.8% were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0% and 73/139 (52.5% were malignant, with SIDC being the most frequent malignant tumor (37.0%. Among 52 false-negative cases, SIDC was significantly more frequent (42.3% than DCIS (P = 0.0049 and Papi-tub (P = 0.001. There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for

  13. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    International Nuclear Information System (INIS)

    Zubizarreta Alberdi, Raquel; Llanes, Ana B.F.; Ortega, Raquel Almazan; Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells; Queiro Verdes, Teresa; Natal Ramos, Carmen; Sanz, Maria Ederra; Salas Trejo, Dolores

    2011-01-01

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p 14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  14. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  15. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  16. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  17. Waiting time and the psychosocial consequences of false-positive mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert; Brodersen, John

    2015-01-01

    Background: There is wide variation in the psychosocial response to false-positive mammography. We aimed to assess whether women having to wait longer to exclude cancer had increased psychosocial consequences that persisted after cancer was ruled out. Findings: We selected women with false......-positive mammography (n = 272), screened for breast cancer in Copenhagen and Funen (Denmark) over a 1-year period. We measured psychosocial consequences immediately before women attended their recall visit and 1, 6, 18 and 36 months after women received their final diagnosis. After women were told that cancer had been...... ruled out, adverse psychosocial consequences decreased with time. We found no statistically significant differences between women who had cancer ruled out immediately at the recall visit (waiting time of 0) and women who had to wait longer before cancer was ruled out (waiting times 1-30, 30...

  18. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    Science.gov (United States)

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  19. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  20. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  1. False Positive Radioiodinated Metaiodobenzylguanidine (123I-MIBG Uptake in Undifferentiated Adrenal Malignant Tumor

    Directory of Open Access Journals (Sweden)

    Hee Soo Jung

    2015-01-01

    Full Text Available 123I-Metaiodobenzylguanidine (123I-MIBG scintigraphy is a widely used functional imaging tool with a high degree of sensitivity and specificity in diagnosis of pheochromocytoma. However, rare cases of false positive reactions have been reported. A 67-year-old male patient was admitted with epigastric pain. Abdominal computed tomography (CT revealed a heterogeneous left adrenal mass 6 cm in diameter; following hormone testing, 123I-MIBG scintigraphy was performed to determine the presence of pheochromocytoma, which confirmed eccentric uptake by a large left adrenal gland mass. Chest CT and PET-CT confirmed metastatic lymphadenopathy; therefore, endobronchial ultrasound transbronchial needle aspiration was performed. Metastatic carcinoma of unknown origin was suspected from a lymph node biopsy, and surgical resection was performed for definitive diagnosis and correction of excess hormonal secretion. A final diagnosis of undifferentiated adrenal malignant tumor was rendered, instead of histologically malignant pheochromocytoma, despite the uptake of 123I-MIBG demonstrated by scintigraphy.

  2. The OGCleaner: filtering false-positive homology clusters.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Snell, Quinn; Bybee, Seth M

    2017-01-01

    Detecting homologous sequences in organisms is an essential step in protein structure and function prediction, gene annotation and phylogenetic tree construction. Heuristic methods are often employed for quality control of putative homology clusters. These heuristics, however, usually only apply to pairwise sequence comparison and do not examine clusters as a whole. We present the Orthology Group Cleaner (the OGCleaner), a tool designed for filtering putative orthology groups as homology or non-homology clusters by considering all sequences in a cluster. The OGCleaner relies on high-quality orthologous groups identified in OrthoDB to train machine learning algorithms that are able to distinguish between true-positive and false-positive homology groups. This package aims to improve the quality of phylogenetic tree construction especially in instances of lower-quality transcriptome assemblies. https://github.com/byucsl/ogcleaner CONTACT: sfujimoto@gmail.comSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. A Demonstration of Regression False Positive Selection in Data Mining

    Science.gov (United States)

    Pinder, Jonathan P.

    2014-01-01

    Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…

  4. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  5. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    Energy Technology Data Exchange (ETDEWEB)

    Zubizarreta Alberdi, Raquel [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Edificio Administrativo da Conselleria de Sanidade, Servicio de Programas Poboacionais de Cribado, Direccion Xeral de Saude Publica e Planificacion, Santiago de Compostela, Galicia (Spain); Llanes, Ana B.F.; Ortega, Raquel Almazan [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells [Department of Epidemiology and Evaluation, Institut Municipal d' Investigacio Medica-Parc de Salut Mar. CIBERESP, Barcelona (Spain); Queiro Verdes, Teresa [Galician Agency for Health Technology Assessment, Public Health and Planning Directorate, Health Office, Galicia (Spain); Natal Ramos, Carmen [Principality of Asturias Breast Cancer Screening Programme, Principality of Asturias (Spain); Sanz, Maria Ederra [Public Health Institute, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Salas Trejo, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia Breast Cancer Screening Programme, Valencia (Spain)

    2011-10-15

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p < 0.001) with greater reading volume in the previous year: OR 0.77 and OR 0.78, respectively, for a reading volume 500-1,999 mammograms and OR 0.59 and OR 0.60 for a reading volume of >14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  6. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  7. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  8. Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.

    Science.gov (United States)

    Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui

    2018-02-01

    Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Comparison of cumulative false-positive risk of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp

    2015-01-01

    INTRODUCTION: In the United States (US), about one-half of women screened with annual mammography have at least one false-positive test after ten screens. The estimate for European women screened ten times biennially is much lower. We evaluate to what extent screening interval, mammogram type......=400,204), between 1991-2012 and 1993-2013, respectively. Model-based cumulative false-positive risks were computed for the entire sample, using two statistical methods (Hubbard Njor) previously used to estimate false-positive risks in the US and Europe. RESULTS: Empirical cumulative risk of at least...... one false-positive test after eight (annual or biennial) screens was 41.9% in BCSC, 16.1% in Copenhagen, and 7.4% in Funen. Variation in screening interval and mammogram type did not explain the differences by country. Using the Hubbard method, the model-based cumulative risks after eight screens...

  10. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  11. Evaluation of false positivity and cross reactivity in the investigation ...

    African Journals Online (AJOL)

    This study evaluated the causes of false positive Human Immunodeficiency Virus test results (F+HIV), cross reactivity of HIV antibodies with other non HIV antibodies, and efficiency of the serial and parallel testing algorithms. 100 blood samples randomly collected from clients attending the Heart to Heart HIV counseling and ...

  12. A false single nucleotide polymorphism generated by gene duplication compromises meat traceability.

    Science.gov (United States)

    Sanz, Arianne; Ordovás, Laura; Zaragoza, Pilar; Sanz, Albina; de Blas, Ignacio; Rodellar, Clementina

    2012-07-01

    Controlling meat traceability using SNPs is an effective method of ensuring food safety. We have analyzed several SNPs to create a panel for bovine genetic identification and traceability studies. One of these was the transversion g.329C>T (Genbank accession no. AJ496781) on the cytochrome P450 17A1 gene, which has been included in previously published panels. Using minisequencing reactions, we have tested 701 samples belonging to eight Spanish cattle breeds. Surprisingly, an excess of heterozygotes was detected, implying an extreme departure from Hardy-Weinberg equilibrium (PT SNP is a false positive polymorphism, which allows us to explain the inflated heterozygotic value. We recommend that this ambiguous SNP, as well as other polymorphisms located in this region, should not be used in identification, traceability or disease association studies. Annotation of these false SNPs should improve association studies and avoid misinterpretations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  14. Use of Opioid Medications for Employees in Critical Safety or Security Positions and Positions with Safety Sensitive Duties

    Science.gov (United States)

    2017-01-30

    can cause harm) to the physical well-being of or jeopardize the security of the employee , co-workers, customers or the general public through a lapse...DEPARTMENT OF THE ARMY US ARMY PUBLIC HEALTH CENTER 5158 BLACKHAWK ROAD ABERDEEN PROVING GROUND MARYLAND 21010-5403 Directorate of Clinical... Employees in Critical Safety or Security Positions and Positions with Safety Sensitive Duties. 1. REFERENCES. A. Army Regulation 40-5, Preventive

  15. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    Science.gov (United States)

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  16. The reaction index and positivity ratio revisited

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Andersen, Flemming

    2008-01-01

    BACKGROUND AND OBJECTIVES: Assessing the quality of patch test preparations continues to be a challenge. 2 parameters, the reaction index (RI) and positivity ratio (PR), have been proposed as quality indicators by the Information Network of Departments of Dermatology (IVDK). The value of these st......BACKGROUND AND OBJECTIVES: Assessing the quality of patch test preparations continues to be a challenge. 2 parameters, the reaction index (RI) and positivity ratio (PR), have been proposed as quality indicators by the Information Network of Departments of Dermatology (IVDK). The value...

  17. Performance quantification of clustering algorithms for false positive removal in fMRI by ROC curves

    Directory of Open Access Journals (Sweden)

    André Salles Cunha Peres

    Full Text Available Abstract Introduction Functional magnetic resonance imaging (fMRI is a non-invasive technique that allows the detection of specific cerebral functions in humans based on hemodynamic changes. The contrast changes are about 5%, making visual inspection impossible. Thus, statistic strategies are applied to infer which brain region is engaged in a task. However, the traditional methods like general linear model and cross-correlation utilize voxel-wise calculation, introducing a lot of false-positive data. So, in this work we tested post-processing cluster algorithms to diminish the false-positives. Methods In this study, three clustering algorithms (the hierarchical cluster, k-means and self-organizing maps were tested and compared for false-positive removal in the post-processing of cross-correlation analyses. Results Our results showed that the hierarchical cluster presented the best performance to remove the false positives in fMRI, being 2.3 times more accurate than k-means, and 1.9 times more accurate than self-organizing maps. Conclusion The hierarchical cluster presented the best performance in false-positive removal because it uses the inconsistency coefficient threshold, while k-means and self-organizing maps utilize a priori cluster number (centroids and neurons number; thus, the hierarchical cluster avoids clustering scattered voxels, as the inconsistency coefficient threshold allows only the voxels to be clustered that are at a minimum distance to some cluster.

  18. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  19. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  20. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  1. Rapid detection of the positive side reactions in vanadium flow batteries

    International Nuclear Information System (INIS)

    Liu, Le; Li, Zhaohua; Xi, Jingyu; Zhou, Haipeng; Wu, Zenghua; Qiu, Xinping

    2017-01-01

    Highlights: • A method for rapid measurement of the positive side reactions in VFB is presented. • The SOC of positive electrolytes can be detected with resolution of 0.002%. • Side reaction ratios at different charge currents, flow rates are obtained. - Abstract: We present an optical detection method for rapid measurement of the positive side reactions in vanadium flow batteries (VFB). By measuring the transmittance of the positive electrolytes in VFB, the states of charge (SOC) of the positive electrolytes can be detected at very high resolution (better than 0.002% in the SOC range from 98% to 100%), due to the nonlinear transmittance spectra caused by the interactions between V(IV) and V(V) ions. The intensity of the positive side reactions of a VFB can be rapidly measured by a few steps, attributing to the fact that the positive side reactions occur only during the high voltage charging process. The ratios of the positive side reactions at different charge currents and different flow rates are obtained while causing no damage to the battery. This optical detection method can rapidly determine the optimal parameters of the VFB system, providing new means for studying the electrochemical reactions in the VFB system and rapid test in industrial production of VFBs.

  2. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Science.gov (United States)

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  3. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis

    DEFF Research Database (Denmark)

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian

    2016-01-01

    outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction...... of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each...... new trial. For each false positive, we performed TSA, using three different approaches. RESULTS: We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta...

  4. Suture Granuloma Showing False-Positive Findings on FDG-PET

    Directory of Open Access Journals (Sweden)

    Kohei Takahara

    2013-01-01

    Full Text Available We report a case of a 33-year-old male with a mixed germ-cell testicular tumor. Postoperative follow-up FDG-PET revealed concentration of FDG in the left inguinal area which is not tumor metastasis or local recurrence but suture reactivity granuloma. In this paper, we reviewed suture granulomas associated with false-positive findings on FDG-PET after surgery. If FDG-PET will be used more frequently in the future, it will be necessary to refrain from using silk thread in order to prevent any unnecessary surgery.

  5. Relevance of positive patch-test reactions to fragrance mix.

    Science.gov (United States)

    Devos, Steven A; Constandt, Lieve; Tupker, Ron A; Noz, Kathy C; Lucker, Georges P H; Bruynzeel, Derk P; Schuttelaar, Marie-Louise A; Kruyswijk, Mente R J; van Zuuren, Esther J; Vink, Jaqueline; Coenraads, Pieter-Jan; Kiemeney, Lambertus A L M; van der Valk, Pieter G M

    2008-01-01

    Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong reactions. To improve the appraisal of FM patch-test reactions, we studied the relevance of reactions of different strength. We also studied the predictive value of the following on the relevance of the initial FM patch-test results: patch-test results of a repeated FM test; results of patch tests with balsam of Peru, colophony, and ingredients of the mix; and (history of) atopic dermatitis. One hundred thirty-eight patients who had doubtful positive (?+) or positive (+ to +++) reactions were included in the study. We determined relevance by history taking, location and course of the dermatitis, and additional patch testing. Patients were retested with FM and with each ingredient separately. The relevance of reactions to FM increases with the strength of the reactions. Predictors of relevance are the results of retesting with FM, the results of tests with the ingredients, and a history and/or present symptoms of atopic dermatitis. Retesting with FM and its ingredients may add to the benefit of patch testing.

  6. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    Science.gov (United States)

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested

  7. Newly formed skeletal muscle fibers are prone to false positive immunostaining by rabbit antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Kliem, Anette; Schrøder, Henrik Daa

    2011-01-01

    rely on controls that reveal non-specific binding by the secondary antibody and neglect that the primary rabbit antibody itself may cause false positive staining of the muscle. We suggest that reliable immuno-based protein detection in newly formed muscle fibers at least requires a nonsense rabbit......Reports on muscle biology and regeneration often implicate immuno(cyto/histo)chemical protein characterization using rabbit polyclonal antibodies. In this study we demonstrate that newly formed myofibers are especially prone to false positive staining by rabbit antibodies and this unwanted staining...

  8. PRE-SPECTROSCOPIC FALSE-POSITIVE ELIMINATION OF KEPLER PLANET CANDIDATES

    International Nuclear Information System (INIS)

    Batalha, Natalie M.; Rowe, Jason F.; Borucki, William J.; Koch, David G.; Lissauer, Jack J.; Gilliland, Ronald L.; Jenkins, Jon J.; Caldwell, Douglas; Dunham, Edward W.; Gautier, Thomas N.; Howell, Steve B.; Latham, David W.; Marcy, Geoff W.; Prsa, Andrej

    2010-01-01

    Ten days of commissioning data (Quarter 0) and 33 days of science data (Quarter 1) yield instrumental flux time series of ∼150,000 stars that were combed for transit events, termed threshold crossing events(TCE), each having a total detection statistic above 7.1σ. TCE light curves are modeled as star+planet systems. Those returning a companion radius smaller than 2R J are assigned a Kepler Object of Interest (KOI) number. The raw flux, pixel flux, and flux-weighted centroids of every KOI are scrutinized to assess the likelihood of being an astrophysical false positive versus the likelihood of being a planetary companion. This vetting using Kepler data is referred to as data validation (DV). Herein, we describe the DV metrics and graphics used to identify viable planet candidates amongst the KOIs. Light curve modeling tests for (1) the difference in depth of the odd- versus even-numbered transits, (2) evidence of ellipsoidal variations, and (3) evidence of a secondary eclipse event at phase = 0.5. Flux-weighted centroids are used to test for signals correlated with transit events with a magnitude and direction indicative of a background eclipsing binary. Centroid time series are complimented by analysis of images taken in-transit versus out-of-transit, the difference often revealing the pixel contributing the most to the flux change during transit. Examples are shown to illustrate each test. Candidates passing DV are submitted to ground-based observers for further false-positive elimination or confirmation/characterization.

  9. ST-Segment Depression in Hyperventilation Indicates a False Positive Exercise Test in Patients with Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Andreas P. Michaelides

    2010-01-01

    Full Text Available Objectives. Mitral valve prolapse (MVP is a known cause for false positive exercise test (ET. The purpose of this study was to establish additional electrocardiographic criteria to distinguish the false positive exercise results in patients with MVP. Methods. We studied 218 consecutive patients ( years, 103 males with MVP (according to echocardiographic study, and positive treadmill ET was performed due to multiple cardiovascular risk factors or angina-like symptoms. A coronary angiography was performed to detect coronary artery disease (CAD. Results. From 218 patients, 90 (group A presented with normal coronary arteries according to the angiography (false positive ET while the rest 128 (group B presented with CAD. ST-segment depression in hyperventilation phase was present in 54 patients of group A (60% while only in 14 patients of group B (11%, . Conclusions. Presence of ST-segment depression in hyperventilation phase favors a false positive ET in patients with MVP.

  10. 30 CFR 56.7052 - Drilling positions.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drilling positions. 56.7052 Section 56.7052... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7052 Drilling positions. Persons shall not drill from— (a) Positions which hinder...

  11. Proteins interacting with cloning scars: a source of false positive protein-protein interactions.

    Science.gov (United States)

    Banks, Charles A S; Boanca, Gina; Lee, Zachary T; Florens, Laurence; Washburn, Michael P

    2015-02-23

    A common approach for exploring the interactome, the network of protein-protein interactions in cells, uses a commercially available ORF library to express affinity tagged bait proteins; these can be expressed in cells and endogenous cellular proteins that copurify with the bait can be identified as putative interacting proteins using mass spectrometry. Control experiments can be used to limit false-positive results, but in many cases, there are still a surprising number of prey proteins that appear to copurify specifically with the bait. Here, we have identified one source of false-positive interactions in such studies. We have found that a combination of: 1) the variable sequence of the C-terminus of the bait with 2) a C-terminal valine "cloning scar" present in a commercially available ORF library, can in some cases create a peptide motif that results in the aberrant co-purification of endogenous cellular proteins. Control experiments may not identify false positives resulting from such artificial motifs, as aberrant binding depends on sequences that vary from one bait to another. It is possible that such cryptic protein binding might occur in other systems using affinity tagged proteins; this study highlights the importance of conducting careful follow-up studies where novel protein-protein interactions are suspected.

  12. Protein complex prediction via dense subgraphs and false positive analysis.

    Directory of Open Access Journals (Sweden)

    Cecilia Hernandez

    Full Text Available Many proteins work together with others in groups called complexes in order to achieve a specific function. Discovering protein complexes is important for understanding biological processes and predict protein functions in living organisms. Large-scale and throughput techniques have made possible to compile protein-protein interaction networks (PPI networks, which have been used in several computational approaches for detecting protein complexes. Those predictions might guide future biologic experimental research. Some approaches are topology-based, where highly connected proteins are predicted to be complexes; some propose different clustering algorithms using partitioning, overlaps among clusters for networks modeled with unweighted or weighted graphs; and others use density of clusters and information based on protein functionality. However, some schemes still require much processing time or the quality of their results can be improved. Furthermore, most of the results obtained with computational tools are not accompanied by an analysis of false positives. We propose an effective and efficient mining algorithm for discovering highly connected subgraphs, which is our base for defining protein complexes. Our representation is based on transforming the PPI network into a directed acyclic graph that reduces the number of represented edges and the search space for discovering subgraphs. Our approach considers weighted and unweighted PPI networks. We compare our best alternative using PPI networks from Saccharomyces cerevisiae (yeast and Homo sapiens (human with state-of-the-art approaches in terms of clustering, biological metrics and execution times, as well as three gold standards for yeast and two for human. Furthermore, we analyze false positive predicted complexes searching the PDBe (Protein Data Bank in Europe database in order to identify matching protein complexes that have been purified and structurally characterized. Our analysis shows

  13. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  14. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  15. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  16. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  17. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    -ups at 2 and 12 months postscreening. At 2 months, there was a moderate multivariate effect of group on distress; and intrusive thinking and worry about breast cancer, in particular, were most frequent amongst the false positives. Intrusive thinking still prevailed at 12 months, in addition to a higher...... findings (n=1407), false-positive findings (n=492) and referents from outside the screening programme (n=1718, age 48-49 years). Distress was measured as illness worry, anxiety, depression, cancer beliefs and early detection behaviour. Measurements were one month before screening invitation with follow...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  18. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  19. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    Science.gov (United States)

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  20. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  1. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  2. Detection of Yersinia enterocolitica serotype O:9 in the faeces of cattle with false positive reactions in serological tests for brucellosis in Ireland.

    Science.gov (United States)

    O'Grady, Don; Kenny, Kevin; Power, Seamus; Egan, John; Ryan, Fergus

    2016-10-01

    Intestinal infection by Yersinia enterocolitica serotype O:9 (YeO9) in cattle has been linked to false positive serological reactivity (FPSR) in diagnostic tests for brucellosis. Although eradicated in Ireland, brucellosis monitoring still identifies seropositive animals, usually one or two (termed singletons) per herd, which are classed as FPSR. To investigate a link between FPSR and YeO9, faeces and blood were collected from singleton FPSR cattle, and from companion animals, in eight selected herds with more than one FPSR animal, for YeO9 culture and Brucella serology. YeO9 was isolated from 76/474 (16%) FPSR singletons in 309 herds, but not from any of 621 animals in 122 control non-FPSR herds. In the FPSR herds 52/187 (27.8%) animals were culture positive, and 17% of the isolates were from seronegative animals. Seropositive animals were more likely to have a rising antibody titre when culture positive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  4. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    International Nuclear Information System (INIS)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.; Stuzman, R.E.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadal function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men

  5. 30 CFR 57.7052 - Drilling positions.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drilling positions. 57.7052 Section 57.7052... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7052 Drilling positions. Persons shall not drill...

  6. Limited agreement of independent RNAi screens for virus-required host genes owes more to false-negative than false-positive factors.

    Directory of Open Access Journals (Sweden)

    Linhui Hao

    Full Text Available Systematic, genome-wide RNA interference (RNAi analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%. However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis.

  7. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  9. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  10. Detection of Biological False Positive Syphilis Serum Reactions ...

    African Journals Online (AJOL)

    A comparative evaluation of reagin tests (Wassermann, VDRL, RPR) and fluorescent treponema antibody absorption tests (FTA-ABS) performed on blood specimens from 5 271 persons (2 493 pregnant women, 1 130 apparently healthy prospective employees, 1 345 newborn babies and 303 leprosy patients) showed that ...

  11. [Enlightenment of adverse reaction monitoring on safety evaluation of traditional Chinese medicines].

    Science.gov (United States)

    Song, Hai-bo; Du, Xiao-xi; Ren, Jing-tian; Yang, Le; Guo, Xiao-xin; Pang, Yu

    2015-04-01

    The adverse reaction monitoring is important in warning the risks of traditional Chinese medicines at an early stage, finding potential quality problems and ensuring the safe clinical medication. In the study, efforts were made to investigate the risk signal mining techniques in line with the characteristics of traditional Chinese medicines, particularly the complexity in component, processing, compatibility, preparation and clinical medication, find early risk signals of traditional Chinese medicines and establish a traditional Chinese medicine safety evaluation system based on adverse reaction risk signals, in order to improve the target studies on traditional Chinese medicine safety, effective and timely control risks and solve the existing frequent safety issue in traditional Chinese medicines.

  12. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  13. Parental knowledge reduces long term anxiety induced by false-positive test results after newborn screening for cystic fibrosis

    NARCIS (Netherlands)

    Vernooij-van Langen, A.M.M.; Pal, S.M. van der; Reijntjens, A.J.T.; Loeber, J.G.; Dompeling, E.; Dankert-Roelse, J.E.

    2014-01-01

    Background: False-positive screening results in newborn screening for cystic fibrosis may lead to parental stress, family relationship problems and a changed perception of the child's health. Aim of the study: To evaluate whether parental anxiety induced by a false positive screening result

  14. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  15. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  16. A False Positive I-131 Metastatic Survey Caused by Radioactive Iodine Uptake by a Benign Thymic Cyst

    Directory of Open Access Journals (Sweden)

    Avneet K. Singh

    2017-01-01

    Full Text Available Thyroid carcinoma is the most common endocrine malignancy in the United States with increasing incidence and diagnosis but stable mortality. Differentiated thyroid cancer rarely presents with distant metastases and is associated with a low risk of morbidity and mortality. Despite this, current protocols recommend remnant ablation with radioactive iodine and evaluation for local and distant metastasis in some patients with higher risk disease. There are several case reports of false positive results of metastatic surveys that are either normal physiologic variants or other pathological findings. Most false positive findings are associated with tissue that has physiologic increased uptake of I-131, such as breast tissue or lung tissue; pathological findings such as thymic cysts are also known to have increased uptake. Our case describes a rare finding of a thymic cyst found on a false positive I-131 metastatic survey. The patient was taken for surgical excision and the final pathology was a benign thymic cyst. Given that pulmonary metastases of differentiated thyroid cancer are rare, thymic cysts, though also rare, must be part of the differential diagnosis for false positive findings on an I-131 survey.

  17. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    Science.gov (United States)

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  18. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  19. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  20. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  1. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  2. One Hundred False-Positive Amphetamine Specimens Characterized by Liquid Chromatography Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Marin, Stephanie J; Doyle, Kelly; Chang, Annie; Concheiro-Guisan, Marta; Huestis, Marilyn A; Johnson-Davis, Kamisha L

    2016-01-01

    Some amphetamine (AMP) and ecstacy (MDMA) urine immunoassay (IA) kits are prone to false-positive results due to poor specificity of the antibody. We employed two techniques, high-resolution mass spectrometry (HRMS) and an in silico structure search, to identify compounds likely to cause false-positive results. Hundred false-positive IA specimens for AMP and/or MDMA were analyzed by an Agilent 6230 time-of-flight (TOF) mass spectrometer. Separately, SciFinder (Chemical Abstracts) was used as an in silico structure search to generate a library of compounds that are known to cross-react with AMP/MDMA IAs. Chemical formulas and exact masses of 145 structures were then compared against masses identified by TOF. Compounds known to have cross-reactivity with the IAs were identified in the structure-based search. The chemical formulas and exact masses of 145 structures (of 20 chemical formulas) were compared against masses identified by TOF. Urine analysis by HRMS correlates accurate mass with chemical formulae, but provides little information regarding compound structure. Structural data of targeted antigens can be utilized to correlate HRMS-derived chemical formulas with structural analogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence

    Directory of Open Access Journals (Sweden)

    Phillip eGrant

    2014-09-01

    Full Text Available Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals.In this study we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy.Our results support findings that both state and trait positive schizotypy explain significant variance in seeing things that are not there and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  4. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence.

    Science.gov (United States)

    Grant, Phillip; Balser, Mona; Munk, Aisha Judith Leila; Linder, Jens; Hennig, Juergen

    2014-01-01

    Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive) schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially, the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals. In this study, we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word, or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy. Our results support findings that both state and trait positive schizotypy explain significant variance in "seeing things that are not there" and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  5. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  6. False Advertising

    OpenAIRE

    Rhodes, Andrew; Wilson, Chris M

    2016-01-01

    There is widespread evidence that some firms use false advertising to overstate the value of their products. We consider a model in which a policymaker is able to punish such false claims. We characterize an equilibrium where false advertising actively influences rational buyers, and analyze the effects of policy under different welfare objectives. We establish precise conditions where policy optimally permits a positive level of false advertising, and show how these conditions vary intuitive...

  7. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  8. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis

    Directory of Open Access Journals (Sweden)

    Rudielle A. Rodrigues

    Full Text Available ABSTRACT: According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT, the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT of the Ministry of Agriculture, Livestock and Food Supply (MAPA, the caudal fold test and the comparative intradermal tuberculin test (CITT. The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4% were negative, 14 (26.4% were positive and seven (13.2% results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0% of the animals with negative CITT results were culture positive (confirmed by PCR and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success.

  9. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 3. Apparent discrepancies between LLNA and GPMT sensitisation potential: False positives or differences in sensitivity?

    Science.gov (United States)

    Roberts, David W; Schultz, Terry W; Api, Anne Marie

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  11. False-Positive Rate Determination of Protein Target Discovery using a Covalent Modification- and Mass Spectrometry-Based Proteomics Platform

    Science.gov (United States)

    Strickland, Erin C.; Geer, M. Ariel; Hong, Jiyong; Fitzgerald, Michael C.

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2 % and analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  12. Early Disseminated Lyme Disease Causing False-Positive Serology for Primary Epstein-Barr Virus Infection: Report of 2 Cases.

    Science.gov (United States)

    Pavletic, Adriana J; Marques, Adriana R

    2017-07-15

    False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. 36 CFR 4.15 - Safety belts.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Safety belts. 4.15 Section 4... TRAFFIC SAFETY § 4.15 Safety belts. (a) Each operator and passenger occupying any seating position of a motor vehicle in a park area will have the safety belt or child restraint system properly fastened at...

  14. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    Science.gov (United States)

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  16. Distinguishing Binders from False Positives by Free Energy Calculations: Fragment Screening Against the Flap Site of HIV Protease

    Science.gov (United States)

    2015-01-01

    Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630

  17. Factors associated with false-positive self-reported adherence to antihypertensive drugs.

    Science.gov (United States)

    Tedla, Y G; Bautista, L E

    2017-05-01

    Self-reported medication adherence is known to overestimate true adherence. However, little is known about patient factors that may contribute to the upward bias in self-reported medication adherence. The objective of this study is to examine whether demographic, behavioral, medication and mood factors are associated with being a false-positive self-reported adherer (FPA) to antihypertensive drug treatment. We studied 175 patients (mean age: 50 years; 57% men) from primary-care clinics starting antihypertensive drug treatment. Self-reported adherence (SRA) was measured with the Medication Adherence Report Scale (MARS) and by the number of drug doses missed in the previous week/month, and compared with pill count adherence ratio (PCAR) as gold standard. Data on adherence, demographic, behavioral, medication and mood factors were collected at baseline and every 3 months up to 1 year. FPA was defined as being a non-adherer by PCAR and an adherer by self-report. Mixed effect logistic regression was used for the analysis. Twenty percent of participants were FPA. Anxiety increased (odds ratio (OR): 3.00; P=0.01), whereas smoking (OR: 0.40; P=0.03) and drug side effects (OR: 0.46, P=0.03) decreased the probability for FPA by MARS. Education below high-school completion increased the probability of being an FPA as measured by missing doses in the last month (OR: 1.66; P=0.04) and last week (OR: 1.88; P=0.02). The validity of SRA varies significantly according to drug side effects, behavioral factors and patient's mood. Careful consideration should be given to the use of self-reported measures of adherence among patients likely to be false-positive adherers.

  18. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A. P.; Stentiford, Grant D.; Flegel, Timothy W.; Sritunyalucksana, Kallaya

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers. PMID:27832178

  19. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms.

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A P; Stentiford, Grant D; Flegel, Timothy W; Sritunyalucksana, Kallaya; Itsathitphaisarn, Ornchuma

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers.

  20. Data from Paper “False-Positive Psychology: Undisclosed Flexibility in Data Collection and Analysis Allows Presenting Anything as Significant”

    Directory of Open Access Journals (Sweden)

    Joseph P Simmons

    2014-02-01

    Full Text Available The data includes measures collected for the two experiments reported in “False-Positive Psychology” [1] where listening to a randomly assigned song made people feel younger (Study 1 or actually be younger (Study 2. These data are useful because they illustrate inflations of false positive rates due to flexibility in data collection, analysis, and reporting of results. Data are useful for educational purposes.

  1. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Science.gov (United States)

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  2. PIPIDA scintigraphy for cholecystitis: false positives in alcoholism and total parenteral nutrition

    International Nuclear Information System (INIS)

    Shuman, W.P.; Gibbs, P.; Rudd, T.G.; Mack, L.A.

    1982-01-01

    A review of gallbladder scintigraphy in patients with potentially compromised hepatobiliary function revealed two groups in whom cholecystitis might be mistakenly diagnosed. In 200 consecutive hospitalized patients studied with technetium-99m-PIPIDA for acute cholecystitis or cholestasis, there were 41 alcoholics and 17 patients on total parenteral nutrition. In 60% of the alcoholics and 92% of those on parenteral nutrition, absent or delayed visualization of the gallbladder occurred without physical or clinical evidence of cholecystitis. A cholecystagogue, sincalide, did not prevent the false-positive features which presumably are due to altered bile flow kinetics related to alcoholism and parenteral nutrition. Four patients on parenteral nutrition undergoing cholecystectomy for suspected cholecystitis had normal gallbladders filled with jellylike viscous thick bile. A positive (nonvisualized or delayed visualized) gallbladder PIPIDA scintigram in these two populations should not be interpreted as indicating a need for cholecystectomy

  3. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    Science.gov (United States)

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  4. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    Science.gov (United States)

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; phemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; phemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; pHemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  5. Cross-reactive Carbohydrate Determinant Contributes to the False Positive IgE Antibody to Peanut

    Directory of Open Access Journals (Sweden)

    Komei Ito

    2005-01-01

    Conclusions: Social education about the features of peanut allergy is needed in Japan. Anti-CCD IgE antibody was suggested to be one of the mechanisms contributing to the false positive detection of peanut IgE. Detection of anti-HRP or anti-bromelain IgE can be a useful tool to recognize the presence of anti-CCD antibodies.

  6. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  7. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  8. False-positive head-impulse test in cerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Olympia eKremmyda

    2012-11-01

    Full Text Available Abstract:The objective of this study was to compare the findings of the bedside head impulse test (HIT, passive head rotation gain, and caloric irrigation in patients with cerebellar ataxia (CA. In 16 patients with CA and bilaterally pathological bedside HIT, VOR gains were measured during HIT and passive head rotation by scleral search coil technique. Eight of the patients had pathologically reduced caloric responsiveness, while the other eight had normal caloric responses. Those with normal calorics showed a slightly reduced HIT gain (mean±SD: 0.73±0.15. In those with pathological calorics, gains 80ms and 100 ms after the HIT as well as the passive rotation VOR gains were significantly lower. The corrective saccade after head turn occurred earlier in patients with pathological calorics (111±62 ms after onset of the HIT than in those with normal calorics. (191±17 ms, p=0.0064 We indentified two groups of patients with CA: those with an isolated moderate HIT deficit only, probably due to floccular dysfunction, and those with combined HIT, passive rotation and caloric deficit, probably due to a peripheral vestibular deficit. From a clinical point of view, these results show that the bedside HIT alone can be false positive for establishing a diagnosis of a bilateral peripheral vestibular deficit in patients with CA.

  9. A FALSE POSITIVE FOR OCEAN GLINT ON EXOPLANETS: THE LATITUDE-ALBEDO EFFECT

    International Nuclear Information System (INIS)

    Cowan, Nicolas B.; Abbot, Dorian S.; Voigt, Aiko

    2012-01-01

    Identifying liquid water on the surface of planets is a high priority, as this traditionally defines habitability. One proposed signature of oceans is specular reflection ('glint'), which increases the apparent albedo of a planet at crescent phases. We post-process a global climate model of an Earth-like planet to simulate reflected light curves. Significantly, we obtain glint-like phase variations even though we do not include specular reflection in our model. This false positive is the product of two generic properties: (1) for modest obliquities, a planet's poles receive less orbit-averaged stellar flux than its equator, so the poles are more likely to be covered in highly reflective snow and ice; and (2) we show that reflected light from a modest-obliquity planet at crescent phases probes higher latitudes than at gibbous phases, therefore a planet's apparent albedo will naturally increase at crescent phase. We suggest that this 'latitude-albedo effect' will operate even for large obliquities: in that case the equator receives less orbit-averaged flux than the poles, and the equator is preferentially sampled at crescent phase. Using rotational and orbital color variations to map the surfaces of directly imaged planets and estimate their obliquity will therefore be a necessary pre-condition for properly interpreting their reflected phase variations. The latitude-albedo effect is a particularly convincing glint false positive for zero-obliquity planets, and such worlds are not amenable to latitudinal mapping. This effect severely limits the utility of specular reflection for detecting oceans on exoplanets.

  10. Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model

    International Nuclear Information System (INIS)

    Ayres, Fabio J.; Rangayyan, Rangaraj M.

    2007-01-01

    Objective One of the commonly missed signs of breast cancer is architectural distortion. We have developed techniques for the detection of architectural distortion in mammograms, based on the analysis of oriented texture through the application of Gabor filters and a linear phase portrait model. In this paper, we propose constraining the shape of the general phase portrait model as a means to reduce the false-positive rate in the detection of architectural distortion. Material and methods The methods were tested with one set of 19 cases of architectural distortion and 41 normal mammograms, and with another set of 37 cases of architectural distortion. Results Sensitivity rates of 84% with 4.5 false positives per image and 81% with 10 false positives per image were obtained for the two sets of images. Conclusion The adoption of a constrained phase portrait model with a symmetric matrix and the incorporation of its condition number in the analysis resulted in a reduction in the false-positive rate in the detection of architectural distortion. The proposed techniques, dedicated for the detection and localization of architectural distortion, should lead to efficient detection of early signs of breast cancer. (orig.)

  11. Prenatal ultrasound screening: false positive soft markers may alter maternal representations and mother-infant interaction.

    Directory of Open Access Journals (Sweden)

    Sylvie Viaux-Savelon

    Full Text Available In up to 5% of pregnancies, ultrasound screening detects a "soft marker" (SM that places the foetus at risk for a severe abnormality. In most cases, prenatal diagnostic work-up rules out a severe defect. We aimed to study the effects of false positive SM on maternal emotional status, maternal representations of the infant, and mother-infant interaction.Utilizing an extreme-case prospective case control design, we selected from a group of 244 women undergoing ultrasound, 19 pregnant women whose foetus had a positive SM screening and a reassuring diagnostic work up, and 19 controls without SM matched for age and education. In the third trimester of pregnancy, within one week after delivery, and 2 months postpartum, we assessed anxiety, depression, and maternal representations. Mother-infant interactions were videotaped during feeding within one week after delivery and again at 2 months postpartum and coded blindly using the Coding Interactive Behavior (CIB scales. Anxiety and depression scores were significantly higher at all assessment points in the SM group. Maternal representations were also different between SM and control groups at all study time. Perturbations to early mother-infant interactions were observed in the SM group. These dyads showed greater dysregulation, lower maternal sensitivity, higher maternal intrusive behaviour and higher infant avoidance. Multivariate analysis showed that maternal representation and depression at third trimester predicted mother-infant interaction.False positive ultrasound screenings for SM are not benign and negatively affect the developing maternal-infant attachment. Medical efforts should be directed to minimize as much as possible such false diagnoses, and to limit their psychological adverse consequences.

  12. 47 CFR 80.1114 - False distress alerts.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1114 False distress alerts. The provisions of §§ 80.334 and 80.335 apply to...

  13. Reduction of lymph tissue false positives in pulmonary embolism detection

    Science.gov (United States)

    Ghanem, Bernard; Liang, Jianming; Bi, Jinbo; Salganicoff, Marcos; Krishnan, Arun

    2008-03-01

    Pulmonary embolism (PE) is a serious medical condition, characterized by the partial/complete blockage of an artery within the lungs. We have previously developed a fast yet effective approach for computer aided detection of PE in computed topographic pulmonary angiography (CTPA),1 which is capable of detecting both acute and chronic PEs, achieving a benchmark performance of 78% sensitivity at 4 false positives (FPs) per volume. By reviewing the FPs generated by this system, we found the most dominant type of FP, roughly one third of all FPs, to be lymph/connective tissue. In this paper, we propose a novel approach that specifically aims at reducing this FP type. Our idea is to explicitly exploit the anatomical context configuration of PE and lymph tissue in the lungs: a lymph FP connects to the airway and is located outside the artery, while a true PE should not connect to the airway and must be inside the artery. To realize this idea, given a detected candidate (i.e. a cluster of suspicious voxels), we compute a set of contextual features, including its distance to the airway based on local distance transform and its relative position to the artery based on fast tensor voting and Hessian "vesselness" scores. Our tests on unseen cases show that these features can reduce the lymph FPs by 59%, while improving the overall sensitivity by 3.4%.

  14. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    Directory of Open Access Journals (Sweden)

    Fuminori Sakurai

    2016-01-01

    Full Text Available Circulating tumor cells (CTCs are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP–expressing conditionally replicating adenovirus (Ad (rAd-GFP was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells.

  15. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  16. UNDERSTANDING OR NURSES' REACTIONS TO ERRORS AND USING THIS UNDERSTANDING TO IMPROVE PATIENT SAFETY.

    Science.gov (United States)

    Taifoori, Ladan; Valiee, Sina

    2015-09-01

    The operating room can be home to many different types of nursing errors due to the invasiveness of OR procedures. The nurses' reactions towards errors can be a key factor in patient safety. This article is based on a study, with the aim of investigating nurses' reactions toward nursing errors and the various contributing and resulting factors, conducted at Kurdistan University of Medical Sciences in Sanandaj, Iran in 2014. The goal of the study was to determine how OR nurses' reacted to nursing errors with the goal of having this information used to improve patient safety. Research was conducted as a cross-sectional descriptive study. The participants were all nurses employed in the operating rooms of the teaching hospitals of Kurdistan University of Medical Sciences, which was selected by a consensus method (170 persons). The information was gathered through questionnaires that focused on demographic information, error definition, reasons for error occurrence, and emotional reactions for error occurrence, and emotional reactions toward the errors. 153 questionnaires were completed and analyzed by SPSS software version 16.0. "Not following sterile technique" (82.4 percent) was the most reported nursing error, "tiredness" (92.8 percent) was the most reported reason for the error occurrence, "being upset at having harmed the patient" (85.6 percent) was the most reported emotional reaction after error occurrence", with "decision making for a better approach to tasks the next time" (97.7 percent) as the most common goal and "paying more attention to details" (98 percent) was the most reported planned strategy for future improved outcomes. While healthcare facilities are focused on planning for the prevention and elimination of errors it was shown that nurses can also benefit from support after error occurrence. Their reactions, and coping strategies, need guidance and, with both individual and organizational support, can be a factor in improving patient safety.

  17. Relevance of positive patch-test reactions to fragrance mix.

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.; Kruyswijk, M.R.; Zuuren, E.J. van; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; Valk, P.G.M. van der

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  18. Relevance of positive patch-test reactions to fragrance mix

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.A.; Kruyswijk, M.R.J.; van Zuuren, E.J.; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; van der Valk, P.G.M.

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  19. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  20. Shape based automated detection of pulmonary nodules with surface feature based false positive reduction

    International Nuclear Information System (INIS)

    Nomura, Y.; Itoh, H.; Masutani, Y.; Ohtomo, K.; Maeda, E.; Yoshikawa, T.; Hayashi, N.

    2007-01-01

    We proposed a shape based automated detection of pulmonary nodules with surface feature based false positive (FP) reduction. In the proposed system, the FP existing in internal of vessel bifurcation is removed using extracted surface of vessels and nodules. From the validation with 16 chest CT scans, we find that the proposed CAD system achieves 18.7 FPs/scan at 90% sensitivity, and 7.8 FPs/scan at 80% sensitivity. (orig.)

  1. Robust Correlation Analyses: False Positive and Power Validation Using a New Open Source Matlab Toolbox

    Science.gov (United States)

    Pernet, Cyril R.; Wilcox, Rand; Rousselet, Guillaume A.

    2012-01-01

    Pearson’s correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab(R) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand. PMID:23335907

  2. Robust correlation analyses: false positive and power validation using a new open source matlab toolbox.

    Science.gov (United States)

    Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A

    2012-01-01

    Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.

  3. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  4. With sadness comes accuracy; with happiness, false memory: mood and the false memory effect.

    Science.gov (United States)

    Storbeck, Justin; Clore, Gerald L

    2005-10-01

    The Deese-Roediger-McDermott paradigm lures people to produce false memories. Two experiments examined whether induced positive or negative moods would influence this false memory effect. The affect-as-information hypothesis predicts that, on the one hand, positive affective cues experienced as task-relevant feedback encourage relational processing during encoding, which should enhance false memory effects. On the other hand, negative affective cues are hypothesized to encourage item-specific processing at encoding, which should discourage such effects. The results of Experiment 1 are consistent with these predictions: Individuals in negative moods were significantly less likely to show false memory effects than those in positive moods or those whose mood was not manipulated. Experiment 2 introduced inclusion instructions to investigate whether moods had their effects at encoding or retrieval. The results replicated the false memory finding of Experiment 1 and provide evidence that moods influence the accessibility of lures at encoding, rather than influencing monitoring at retrieval of whether lures were actually presented.

  5. The ligase chain reaction as a primary screening tool for the detection of culture positive tuberculosis.

    LENUS (Irish Health Repository)

    O'Connor, T M

    2012-02-03

    BACKGROUND: The ligase chain reaction Mycobacterium tuberculosis assay uses ligase chain reaction technology to detect tuberculous DNA sequences in clinical specimens. A study was undertaken to determine its sensitivity and specificity as a primary screening tool for the detection of culture positive tuberculosis. METHODS: The study was conducted on 2420 clinical specimens (sputum, bronchoalveolar lavage fluid, pleural fluid, urine) submitted for primary screening for Mycobacterium tuberculosis to a regional medical microbiology laboratory. Specimens were tested in parallel with smear, ligase chain reaction, and culture. RESULTS: Thirty nine patients had specimens testing positive by the ligase chain reaction assay. Thirty two patients had newly diagnosed tuberculosis, one had a tuberculosis relapse, three had tuberculosis (on antituberculous therapy when tested), and three had healed tuberculosis. In the newly diagnosed group specimens were smear positive in 21 cases (66%), ligase chain reaction positive in 30 cases (94%), and culture positive in 32 cases (100%). Using a positive culture to diagnose active tuberculosis, the ligase chain reaction assay had a sensitivity of 93.9%, a specificity of 99.8%, a positive predictive value of 83.8%, and a negative predictive value of 99.9%. CONCLUSIONS: This study is the largest clinical trial to date to report the efficacy of the ligase chain reaction as a primary screening tool to detect Mycobacterium tuberculosis infection. The authors conclude that ligase chain reaction is a useful primary screening test for tuberculosis, offering speed and discrimination in the early stages of diagnosis and complementing traditional smear and culture techniques.

  6. Determination of the energetics of the UDP-glucose pyrophosphorylase reaction by positional isotope exchange inhibition

    International Nuclear Information System (INIS)

    Hester, L.S.; Raushel, F.M.

    1987-01-01

    A method has been developed for obtaining qualitative information about enzyme-catalyzed reactions by measuring the inhibitory effects of added substrates on positional isotope exchange rates. It has been demonstrated for ordered kinetic mechanisms that an increase in the concentration of the second substrate to add to the enzyme will result in a linear increase in the ratio of the chemical and positional isotope exchange rates. The slopes and intercepts from these plots can be used to determine the partitioning ratios of binary and ternary enzyme complexes. The method has been applied to the reaction catalyzed by UDP-glucose pyrophosphorylase. A positional isotope exchange reaction was measured within oxygen-18-labeled UTP as a function of variable glucose 1-phosphate concentration in the forward reaction. In the reverse reaction, a positional isotope exchange reaction was measured within oxygen-18-labeled UDP-glucose as a function of increasing pyrophosphate concentration. The results have been interpreted to indicate that the interconversion of the ternary central complexes is fast relative to product dissociation in either direction. In the forward direction, the release of UDP-glucose is slower than the release of pyrophosphate. The release of glucose 1-phosphate is slower than the release of UTP in the reverse reaction

  7. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  8. Japanese position paper on sodium-water reaction testing and design

    International Nuclear Information System (INIS)

    Sato, M.; Hiroi, H.; Tanabe, H.; Miyake, O.; Kuroha, M.; Hoshi, Y.

    1984-01-01

    PNC has been developing the steam generator with helically coiled heat transfer tube bundle and downcommer tubes for the prototype fast reactor Monju since 1968. To establish the safety design against the sodium-water reaction accident was one of the most important R and D items at the start of the development. PNC started the experimental study initially in the large leak region in 1970. Until now, during twelve years, the experimental studies have been performed, which covers the phenomena from a micro leak to a large one, with the use of the SWAT-1 rig, SWAT-2 loop, SWAT-3 loop, and SWAT-4 rigs. The reliable leak detection system is necessary to minimize the damage by the sodium-water reaction. Two groups of efforts have been paid for developing the detection system. One is to develop the leak detector itself, and another is to grasp the hydrogen transport behavior in the sodium in the steam generator and the secondary piping system. Four sodium loops have been used for the development. The development of computer codes has also progressed in parallel with the sodium-water reaction experiments. Three codes have been accomplished for the design tools against the sodium-water reaction. Through the efforts mentioned above, sufficient experiences were obtained for designing and operating the Monju steam generator system

  9. IS HCI THAT IS USED AS A PRESERVATIVE CREATING FALSE POSITIVES FOR TBA IN GROUND WATER

    Science.gov (United States)

    Will hydrochloric acid produce false positives for TBA? Yes, if you heat the sample to get a lower detection limit for TBA. Conventional purge and trap methods at ambient temperature have a reporting limit for TBA between 50 and 100 g/liter. This is higher than the provisiona...

  10. Empirical methods for controlling false positives and estimating confidence in ChIP-Seq peaks

    Directory of Open Access Journals (Sweden)

    Courdy Samir J

    2008-12-01

    Full Text Available Abstract Background High throughput signature sequencing holds many promises, one of which is the ready identification of in vivo transcription factor binding sites, histone modifications, changes in chromatin structure and patterns of DNA methylation across entire genomes. In these experiments, chromatin immunoprecipitation is used to enrich for particular DNA sequences of interest and signature sequencing is used to map the regions to the genome (ChIP-Seq. Elucidation of these sites of DNA-protein binding/modification are proving instrumental in reconstructing networks of gene regulation and chromatin remodelling that direct development, response to cellular perturbation, and neoplastic transformation. Results Here we present a package of algorithms and software that makes use of control input data to reduce false positives and estimate confidence in ChIP-Seq peaks. Several different methods were compared using two simulated spike-in datasets. Use of control input data and a normalized difference score were found to more than double the recovery of ChIP-Seq peaks at a 5% false discovery rate (FDR. Moreover, both a binomial p-value/q-value and an empirical FDR were found to predict the true FDR within 2–3 fold and are more reliable estimators of confidence than a global Poisson p-value. These methods were then used to reanalyze Johnson et al.'s neuron-restrictive silencer factor (NRSF ChIP-Seq data without relying on extensive qPCR validated NRSF sites and the presence of NRSF binding motifs for setting thresholds. Conclusion The methods developed and tested here show considerable promise for reducing false positives and estimating confidence in ChIP-Seq data without any prior knowledge of the chIP target. They are part of a larger open source package freely available from http://useq.sourceforge.net/.

  11. False positive results occurring in a radioimmunoassay for hepatitis A IgM antibody of the IgM class

    Energy Technology Data Exchange (ETDEWEB)

    Bucens, M R; Pietroboni, G R; Harnett, G B [Virus Lab., Combined Microbiology Service, Queen Elizabeth II Medical Centre, Perth, Western Australia

    1983-12-01

    The diagnosis of hepatitis A infection is usually based on the presence of hepatitis A specific IgM in a single serum sample. The fortuitous observation in one patient that this reactivity was apparently still present 19 mth after her original illness led to the discovery that the ABBOTT HAVAB-M kit method may produce false positive results. A series of patients who had previously had hepatitis A was retested and false positive results were found in 6% of this group. Control groups consisted of patients with other acute and chronic liver disorders and other acute viral diseases. No reactivity was detected in the control sera. Sucrose gradient fractionation revealed that the factor responsible for the false positive results was associated only with serum fractions containing IgA and IgG and that it could be removed by absorption of sera with staphylococcal protein A but not by absorption with streptococcus AR1 or by 2-mercaptoethanol treatment. It was concluded that following hepatitis A infection some patients produce a rheumatoid factor-like substance (not of IgM class) which is cleared from the serum in 2-3 yr. The presence of this factor may lead to a misdiagnosis in patients presenting with jaundice.

  12. 29 CFR 2200.39 - Statement of position.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Statement of position. 2200.39 Section 2200.39 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION RULES OF PROCEDURE... intervene, may file a statement of position with respect to any or all issues to be heard. The Judge may...

  13. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  14. Measuring both negative and positive reactions to giving care to cancer patients : psychometric qualities of the Caregiver Reaction Assessment (CRA)

    NARCIS (Netherlands)

    Nijboer, C; Triemstra, M; Sanderman, R.; van den Bos, G.A M

    The Caregiver Reaction Assessment Scale (CRA) is an instrument designed to assess specific aspects of the caregiving situation, including both negative and positive dimensions of caregiving reactions. This paper addresses the psychometric qualities of the CRA in a multicenter study among partners of

  15. Measuring both negative and positive reactions to giving care to cancer patients: psychometric qualities of the Caregiver Reaction Assessment (CRA)

    NARCIS (Netherlands)

    Nijboer, C.; Triemstra, M.; Tempelaar, R.; Sanderman, R.; van den Bos, G. A.

    1999-01-01

    The Caregiver Reaction Assessment Scale (CRA) is an instrument designed to assess specific aspects of the caregiving situation, including both negative and positive dimensions of caregiving reactions. This paper addresses the psychometric qualities of the CRA in a multicenter study among partners of

  16. Reaction Qualifications Revisited

    DEFF Research Database (Denmark)

    Lippert-Rasmussen, Kasper

    2009-01-01

      When, in a competitive sphere, people are selected on the basis of qualifications only, their chances of acquiring positions of advantage may seem to depend entirely upon their abilities, not discriminatory bias. However, if reaction qualifications - i.e. characteristics which contribute...... to a person's effectiveness by causing a favourable reaction in customers, co-workers etc. (for short: recipients) - are involved, this assumption is false. Building on work by Wertheimer, Mason, and Miller, this paper proposes an account of the reaction qualifications that count, from the point of view...... of merit. Specifically, it preserves symmetry between negative evaluations of antimeritocratic bases of selection and negative evaluations of qualifications rooted in comparable antimeritocratic reactions. So if employers should not select among applicants on the basis of their (the employers') racial...

  17. Comparing Positively and Negatively Charged Distonic Radical Ions in Phenylperoxyl Forming Reactions.

    Science.gov (United States)

    Williams, Peggy E; Marshall, David L; Poad, Berwyck L J; Narreddula, Venkateswara R; Kirk, Benjamin B; Trevitt, Adam J; Blanksby, Stephen J

    2018-06-04

    In the gas phase, arylperoxyl forming reactions play a significant role in low-temperature combustion and atmospheric processing of volatile organic compounds. We have previously demonstrated the application of charge-tagged phenyl radicals to explore the outcomes of these reactions using ion trap mass spectrometry. Here, we present a side-by-side comparison of rates and product distributions from the reaction of positively and negatively charge tagged phenyl radicals with dioxygen. The negatively charged distonic radical ions are found to react with significantly greater efficiency than their positively charged analogues. The product distributions of the anion reactions favor products of phenylperoxyl radical decomposition (e.g., phenoxyl radicals and cyclopentadienone), while the comparable fixed-charge cations yield the stabilized phenylperoxyl radical. Electronic structure calculations rationalize these differences as arising from the influence of the charged moiety on the energetics of rate-determining transition states and reaction intermediates within the phenylperoxyl reaction manifold and predict that this influence could extend to intra-molecular charge-radical separations of up to 14.5 Å. Experimental observations of reactions of the novel 4-(1-carboxylatoadamantyl)phenyl radical anion confirm that the influence of the charge on both rate and product distribution can be modulated by increasing the rigidly imposed separation between charge and radical sites. These findings provide a generalizable framework for predicting the influence of charged groups on polarizable radicals in gas phase distonic radical ions. Graphical Abstract.

  18. False positive reaction due to endogenous biotin activity in glandular epithelium of decidua Reação falso positiva em epitélio glandular da decídua devido a atividade endógena de biotina

    Directory of Open Access Journals (Sweden)

    Liliana Cruz Spano

    2005-06-01

    Full Text Available Biotin-labeled probe was used in an in situ hybridisation assay to localize virus infection in formalin-fixed, paraffin embedded tissues taken from eleven abortion cases. Probes for human cytomegalovirus (HCMV, human Parvovirus B19 (B19 and human adenovirus type 2 (HAd2, were labeled with biotin-11-dUTP by nick-translation reaction. Streptavidin-alkaline-phosphatase (SAP was used to detect biotin, followed by 4-nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP solution. Positive reaction was observed in nucleus of glandular ephitelium cells of decidua either in positive or in negative control at first and second gestational trimester. The reaction was not inhibited with blocking solution for alkaline phosphatase endogenous activity and it persisted even with probes omission. The use of adequate negative control permitted to reveal the presence of nuclear biotin in glandular epithelium of decidua, responsible for false positivity in detection systems involving streptavidin biotin system (StrepABC. The stained cells resembled to cytophatic effect due to herpesvirus, which could induce further misinterpretation. The results obtained in this study strongly recommend that DNA detection by in situ hybridisation reaction in gestational endometrium should be done without using StrepABC system.Sondas marcadas com biotina foram utilizadas neste trabalho para detecção de infecção viral por hibridização in situ em tecidos fixados com formalina e embebidos em parafina de 11 casos obtidos de abortamento. Sondas para citomegalovírus humano (HCMV, parvovírus B19 humano (B19 e adenovírus humano tipo 2 (HAd2, foram marcadas com biotina-11-dUTP através da reação de nick-translation. Estreptavidina conjugada com fosfatase alcalina (SAP seguida por solução de 4-nitro-azul de tetrazolio/5-bromo-4-cloro-3-indolil fosfato (NBT/BCIP foram utilizadas para detecção da biotina após a reação de hibridização. Reação positiva foi

  19. Position-specific isotope modeling of organic micropollutants transformation through different reaction pathways

    International Nuclear Information System (INIS)

    Jin, Biao; Rolle, Massimo

    2016-01-01

    The degradation of organic micropollutants occurs via different reaction pathways. Compound specific isotope analysis is a valuable tool to identify such degradation pathways in different environmental systems. We propose a mechanism-based modeling approach that provides a quantitative framework to simultaneously evaluate concentration as well as bulk and position-specific multi-element isotope evolution during the transformation of organic micropollutants. The model explicitly simulates position-specific isotopologues for those atoms that experience isotope effects and, thereby, provides a mechanistic description of isotope fractionation occurring at different molecular positions. To demonstrate specific features of the modeling approach, we simulated the degradation of three selected organic micropollutants: dichlorobenzamide (BAM), isoproturon (IPU) and diclofenac (DCF). The model accurately reproduces the multi-element isotope data observed in previous experimental studies. Furthermore, it precisely captures the dual element isotope trends characteristic of different reaction pathways as well as their range of variation consistent with observed bulk isotope fractionation. It was also possible to directly validate the model capability to predict the evolution of position-specific isotope ratios with available experimental data. Therefore, the approach is useful both for a mechanism-based evaluation of experimental results and as a tool to explore transformation pathways in scenarios for which position-specific isotope data are not yet available. - Highlights: • Mechanism-based, position-specific isotope modeling of micropollutants degradation. • Simultaneous description of concentration and primary and secondary isotope effects. • Key features of the model are demonstrated with three illustrative examples. • Model as a tool to explore reaction mechanisms and to design experiments. - We propose a modeling approach incorporating mechanistic information and

  20. Learning from positively deviant wards to improve patient safety: an observational study protocol.

    Science.gov (United States)

    Baxter, Ruth; Taylor, Natalie; Kellar, Ian; Lawton, Rebecca

    2015-12-11

    Positive deviance is an asset-based approach to improvement which has recently been adopted to improve quality and safety within healthcare. The approach assumes that solutions to problems already exist within communities. Certain groups or individuals identify these solutions and succeed despite having the same resources as others. Within healthcare, positive deviance has previously been applied at individual or organisational levels to improve specific clinical outcomes or processes of care. This study explores whether the positive deviance approach can be applied to multidisciplinary ward teams to address the broad issue of patient safety among elderly patients. Preliminary work analysed National Health Service (NHS) Safety Thermometer data from 34 elderly medical wards to identify 5 'positively deviant' and 5 matched 'comparison' wards. Researchers are blinded to ward status. This protocol describes a multimethod, observational study which will (1) assess the concurrent validity of identifying positively deviant elderly medical wards using NHS Safety Thermometer data and (2) generate hypotheses about how positively deviant wards succeed. Patient and staff perceptions of safety will be assessed on each ward using validated surveys. Correlation and ranking analyses will explore whether this survey data aligns with the routinely collected NHS Safety Thermometer data. Staff focus groups and researcher fieldwork diaries will be completed and qualitative thematic content analysis will be used to generate hypotheses about the strategies, behaviours, team cultures and dynamics that facilitate the delivery of safe patient care. The acceptability and sustainability of strategies identified will also be explored. The South East Scotland Research Ethics Committee 01 approved this study (reference: 14/SS/1085) and NHS Permissions were granted from all trusts. Findings will be published in peer-reviewed, scientific journals, and presented at academic conferences. This study

  1. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  2. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  3. Detecting and avoiding likely false-positive findings - a practical guide.

    Science.gov (United States)

    Forstmeier, Wolfgang; Wagenmakers, Eric-Jan; Parker, Timothy H

    2017-11-01

    Recently there has been a growing concern that many published research findings do not hold up in attempts to replicate them. We argue that this problem may originate from a culture of 'you can publish if you found a significant effect'. This culture creates a systematic bias against the null hypothesis which renders meta-analyses questionable and may even lead to a situation where hypotheses become difficult to falsify. In order to pinpoint the sources of error and possible solutions, we review current scientific practices with regard to their effect on the probability of drawing a false-positive conclusion. We explain why the proportion of published false-positive findings is expected to increase with (i) decreasing sample size, (ii) increasing pursuit of novelty, (iii) various forms of multiple testing and researcher flexibility, and (iv) incorrect P-values, especially due to unaccounted pseudoreplication, i.e. the non-independence of data points (clustered data). We provide examples showing how statistical pitfalls and psychological traps lead to conclusions that are biased and unreliable, and we show how these mistakes can be avoided. Ultimately, we hope to contribute to a culture of 'you can publish if your study is rigorous'. To this end, we highlight promising strategies towards making science more objective. Specifically, we enthusiastically encourage scientists to preregister their studies (including a priori hypotheses and complete analysis plans), to blind observers to treatment groups during data collection and analysis, and unconditionally to report all results. Also, we advocate reallocating some efforts away from seeking novelty and discovery and towards replicating important research findings of one's own and of others for the benefit of the scientific community as a whole. We believe these efforts will be aided by a shift in evaluation criteria away from the current system which values metrics of 'impact' almost exclusively and towards a system

  4. False-positive positron emission tomography appearance with 18F-fluorodeoxyglucose after definitive radiotherapy for cancer of the mobile tongue.

    Science.gov (United States)

    Ariji, Y; Fuwa, N; Kodaira, T; Tachibana, H; Nakamura, T; Satoh, Y; Ariji, E

    2009-01-01

    (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is an effective tool for evaluating the results of radiotherapy. However, some false-positive appearances caused by physiological or pathological accumulation are reported. We report on three patients who showed a high accumulation of FDG in the lingual muscles but had no recurrent tumour after definitive radiotherapy for the mobile tongue. All patients had squamous cell carcinoma of the tongue and received interstitial radiotherapy with small sources. High uptake was seen in the lingual muscles without recurrence or inflammation, based on physical and MR examinations. This false-positive appearance is thought to relate to ill-balanced high activity of the lingual muscles after definitive radiotherapy.

  5. Placing symptoms in context: the role of contextual criteria in reducing false positives in Diagnostic and Statistical Manual of Mental Disorders diagnoses.

    Science.gov (United States)

    Wakefield, Jerome C; First, Michael B

    2012-02-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    Science.gov (United States)

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  7. 33 CFR 147.809 - Mars Tension Leg Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...

  8. MDEP Generic Common Position No DICWG-03. Common position on verification and validation throughout the life cycle of digital safety systems

    International Nuclear Information System (INIS)

    2013-01-01

    Verification and validation (V and V) is essential throughout the life cycle of nuclear power plant safety systems. This common position applies to V and V activities for digital safety systems throughout their life cycles. This encompasses both the software and hardware of such systems. The Digital Instrumentation and Controls Working Group (DICWG) has agreed that a common position on this topic is warranted given the use of Digital I and C in new reactor designs, its safety implications, and the need to develop a common understanding from the perspectives of regulatory authorities. This action follows the DICWG examination of the regulatory requirements of the participating members and of relevant industry standards and IAEA documents. The DICWG proposes a common position based on its recent experience with the new reactor application reviews and operating plant issues

  9. Interpreting the results of the Semmes-Weinstein monofilament test: accounting for false-positive answers in the international consensus on the diabetic foot protocol by a new model.

    Science.gov (United States)

    Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J

    2014-01-01

    The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.

  10. North American Engineering, Procurement, Fabrication and Construction Worker Safety Climate Perception Affected by Job Position

    Directory of Open Access Journals (Sweden)

    Clint Pinion

    2018-04-01

    Full Text Available Understanding and implementing the results of Safety Climate surveys can assist in decreasing occupational injuries and illnesses. The following article presents findings of a cross-sectional study that assessed the relationship between safety climate perceptions and job position among engineering, procurement, fabrication and construction (EPFC employees using a 15-item survey. Descriptive statistics (means and frequencies and an ANACOVA (analysis of covariance were performed on a saturated model. The study had a 62% response rate. Results indicate a statistically significant in mean safety climate scores between job position among EPFC employees when controlling for years in industry and location type (i.e., construction versus fabrication [F (9, 603 = 5.28, p < 0.0001, adjusted R-square = 0.07]. Employee perception of safety climate differed based on the employee’s job position (i.e., laborer, foreman, etc.. Project management reported the highest safety climate scores (0.91, followed by supervisors (0.86, technical support employees and foremen (0.84 and laborers (0.81.

  11. A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

    International Nuclear Information System (INIS)

    Sliski, David H.; Kipping, David M.

    2014-01-01

    Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

  12. False positive localisation of C-11 methionine in a colloid nodule

    International Nuclear Information System (INIS)

    Mahajan, Sonia; Tripathi, Madhavi; Jaimini, Abhinav; Dinesh, Anant

    2011-01-01

    A 45-year-old female diagnosed with carcinoma of the left breast on histopathological examination underwent both 18 F-flourodeoxyglucose (FDG) and 11C-methionine (MET) positron emission tomography/computed tomography (PET/CT) as part of a protocol comparing the utility of these tracers for predicting a response to neoadjuvant chemotherapy in breast carcinoma. Abnormal FDG and MET accumulation was noted in the left breast primary, left axillary lymph nodes, and also in a well-defined nodule present in the left lobe of the thyroid gland. Keeping in mind the possibility of thyroid neoplasm/metastasis, the patient was referred for fine needle aspiration cytology (FNAC) from the thyroid nodule that revealed features of a simple colloid nodule. Focal thyroid lesions incidentally found on 18 F-FDG PET/CT have a high risk of thyroid malignancy. Non-specific accumulation of FDG in thyroid adenomas is also known. This case highlights a potential cause for false positive on C-11 MET PET/CT in colloid adenomas, which should be kept in mind while using this tracer for oncological indications

  13. MDEP Common Position No DICWG08. Common position on the impact of cyber security features on digital I and C safety systems

    International Nuclear Information System (INIS)

    2012-01-01

    Cyber security measures are generally implemented at nuclear facilities to protect against cyber-attacks that may compromise safety. The implementation of such cyber security measures may vary based on site specific requirements and each country's regulatory frameworks. Safety measures and cyber security measures for a nuclear power plant should be designed and implemented so that they do not compromise one another. This common position is intended to only apply to systems classified to the highest level of safety. The Digital Instrumentation and Controls Working Group (DICWG) has agreed that a common position on this topic is warranted given the increase of use of Digital I and C in new reactor designs, its safety implications, and the need to develop a common understanding from the perspectives of regulatory authorities. This action follows the DICWG examination of the regulatory requirements of the participating members and of relevant industry standards and IAEA documents. The DICWG proposes a common position based on its recent experience with the new reactor application reviews and operating plant issues

  14. Significance of Waterway Navigation Positioning Systems On Ship's Manoeuvring Safety

    Science.gov (United States)

    Galor, W.

    The main goal of navigation is to lead the ship to the point of destination safety and efficiently. Various factors may affect ship realisating this process. The ship movement on waterway are mainly limited by water area dimensions (surface and depth). These limitations cause the requirement to realise the proper of ship movement trajectory. In case when this re requirement cant't fulfil then marine accident may happend. This fact is unwanted event caused losses of human health and life, damage or loss of cargo and ship, pollution of natural environment, damage of port structures or blocking the port of its ports and lost of salvage operation. These losses in same cases can be catas- trophical especially while e.i. crude oil spilling could be place. To realise of safety navigation process is needed to embrace the ship's movement trajectory by waterways area. The ship's trajectory is described by manoeuvring lane as a surface of water area which is require to realise of safety ship movement. Many conditions affect to ship manoeuvring line. The main are following: positioning accuracy, ship's manoeuvring features and phenomena's of shore and ship's bulk common affecting. The accuracy of positioning system is most important. This system depends on coast navigation mark- ing which can range many kinds of technical realisation. Mainly used systems based on lights (line), radionavigation (local system or GPS, DGPS), or radars. If accuracy of positiong is higer, then safety of navigation is growing. This article presents these problems exemplifying with approaching channel to ports situated on West Pomera- nian water region.

  15. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

  16. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  17. Multi-scale textural feature extraction and particle swarm optimization based model selection for false positive reduction in mammography.

    Science.gov (United States)

    Zyout, Imad; Czajkowska, Joanna; Grzegorzek, Marcin

    2015-12-01

    The high number of false positives and the resulting number of avoidable breast biopsies are the major problems faced by current mammography Computer Aided Detection (CAD) systems. False positive reduction is not only a requirement for mass but also for calcification CAD systems which are currently deployed for clinical use. This paper tackles two problems related to reducing the number of false positives in the detection of all lesions and masses, respectively. Firstly, textural patterns of breast tissue have been analyzed using several multi-scale textural descriptors based on wavelet and gray level co-occurrence matrix. The second problem addressed in this paper is the parameter selection and performance optimization. For this, we adopt a model selection procedure based on Particle Swarm Optimization (PSO) for selecting the most discriminative textural features and for strengthening the generalization capacity of the supervised learning stage based on a Support Vector Machine (SVM) classifier. For evaluating the proposed methods, two sets of suspicious mammogram regions have been used. The first one, obtained from Digital Database for Screening Mammography (DDSM), contains 1494 regions (1000 normal and 494 abnormal samples). The second set of suspicious regions was obtained from database of Mammographic Image Analysis Society (mini-MIAS) and contains 315 (207 normal and 108 abnormal) samples. Results from both datasets demonstrate the efficiency of using PSO based model selection for optimizing both classifier hyper-parameters and parameters, respectively. Furthermore, the obtained results indicate the promising performance of the proposed textural features and more specifically, those based on co-occurrence matrix of wavelet image representation technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. 78 FR 979 - Petition for Positive Train Control Safety Plan Approval and System Certification of the...

    Science.gov (United States)

    2013-01-07

    ...] Petition for Positive Train Control Safety Plan Approval and System Certification of the Electronic Train... the Federal Railroad Administration (FRA) for Positive Train Control (PTC) Safety Plan (PTCSP) approval and system certification of the Electronic Train Management System (ETMS) as required by 49 U.S.C...

  19. THE POSSIBLE MOON OF KEPLER-90g IS A FALSE POSITIVE

    Energy Technology Data Exchange (ETDEWEB)

    Kipping, D. M.; Torres, G.; Buchhave, L. A. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Huang, X.; Bakos, G. Á. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 05844 (United States); Nesvorný, D. [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States); Schmitt, A. R., E-mail: dkipping@cfa.harvard.edu

    2015-01-20

    The discovery of an exomoon would provide deep insights into planet formation and the habitability of planetary systems, with transiting examples being particularly sought after. Of the hundreds of Kepler planets now discovered, the seven-planet system Kepler-90 is unusual for exhibiting an unidentified transit-like signal in close proximity to one of the transits of the long-period gas-giant Kepler-90g, as noted by Cabrera et al. As part of the ''Hunt for Exomoons with Kepler'' project, we investigate this possible exomoon signal and find it passes all conventional photometric, dynamical, and centroid diagnostic tests. However, pixel-level light curves indicate that the moon-like signal occurs on nearly all of the target's pixels, which we confirm using a novel way of examining pixel-level data which we dub the ''transit centroid''. This test reveals that the possible exomoon to Kepler-90g is likely a false positive, perhaps due to a cosmic ray induced sudden pixel sensitivity dropout. This work highlights the extreme care required for seeking non-periodic low-amplitude transit signals, such as exomoons.

  20. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  1. [False positive results or what's the probability that a significant P-value indicates a true effect?

    Science.gov (United States)

    Cucherat, Michel; Laporte, Silvy

    2017-09-01

    The use of statistical test is central in the clinical trial. At the statistical level, obtaining a Pinformation about the plausibility of the existence of treatment effect. With "Pfalse positive is very high. This is the case if the power is low, if there is an inflation of the alpha risk or if the result is exploratory or chance discoveries. This possibility is important to take into consideration when interpreting the results of clinical trials in order to avoid pushing ahead significant results in appearance, but which are likely to be actually false positive results. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  2. The real-world safety potential of connected vehicle technology.

    Science.gov (United States)

    Doecke, Sam; Grant, Alex; Anderson, Robert W G

    2015-01-01

    This article estimates the safety potential of a current commercially available connected vehicle technology in real-world crashes. Data from the Centre for Automotive Safety Research's at-scene in-depth crash investigations in South Australia were used to simulate the circumstances of real-world crashes. A total of 89 crashes were selected for inclusion in the study. The crashes were selected as representative of the most prevalent crash types for injury or fatal crashes and had potential to be mitigated by connected vehicle technology. The trajectory, speeds, braking, and impact configuration of the selected in-depth cases were replicated in a software package and converted to a file format allowing "replay" of the scenario in real time as input to 2 Cohda Wireless MK2 onboard units. The Cohda Wireless onboard units are a mature connected vehicle technology that has been used in both the German simTD field trial and the U.S. Department of Transport's Safety Pilot project and have been tuned for low false alarm rates when used in the real world. The crash replay was achieved by replacing each of the onboard unit Global Positioning System (GPS) inputs with the simulated data of each of the involved vehicles. The time at which the Cohda Wireless threat detection software issued an elevated warning was used to calculate a new impact speed using 3 different reaction scenarios and 2 levels of braking. It was found that between 37 and 86% of the simulated crashes could be avoided, with highest percentage due a fully autonomous system braking at 0.7 g. The same system also reduced the impact speed relative to the actual crash in all cases. Even when a human reaction time of 1.2 s and moderate braking of 0.4 g was assumed, the impact speed was reduced in 78% of the crashes. Crash types that proved difficult for the threat detection engine were head-on crashes where the approach angle was low and right turn-opposite crashes. These results indicate that connected vehicle

  3. MDEP Generic Common Position No DICWG-01. Common position on the treatment of common cause failure caused by software within digital safety systems

    International Nuclear Information System (INIS)

    2013-01-01

    Common cause failures (CCF)2 have been a significant safety concern for nuclear power plant systems. The increasing dependence on software-in safety systems for nuclear power plants has increased the safety significance of CCF caused by software, when software in redundant channels or portions of safety systems has some common dependency. For example, the effect of systematic failures can lead to a loss of safety in many ways: unwanted actuations, a safety function is not provided when needed. Therefore, nuclear power plants should be systematically protected from the effects of common cause failures caused by software in DI and C safety systems. Software for nuclear power plant safety systems should be of the high quality necessary to help assure against the loss of safety (i.e. developed with high-quality engineering practices, commensurate quality assurance applied, with continuous improvement through corrective actions based on lessons learned from operating experience). However, demonstrating adequate software quality only through verification and validation activities and controls on the development process has proved to be problematic. Therefore, this common position provides guidance for the assessment of the potential for CCF for software. It is recognized that programmable logic devices do not execute software in the conventional sense; however, the application development process using these devices have many similarities with software development, and the deficiencies that may be introduced during the application development process may induce errors in the programmable logic devices that can result in common cause failures of these devices of a type similar to software common cause failure. Although deficiencies with the potential to give rise to software common cause failures can be introduced at all phases of the software life cycle, this common position will only consider the potential for software common cause failures within digital safety system

  4. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    Science.gov (United States)

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  5. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    International Nuclear Information System (INIS)

    Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W.; Bryson, Stephen T.; Borucki, William J.; Knutson, Heather A.; Batalha, Natalie M.; Deming, Drake; Ford, Eric B.; Fortney, Jonathan J.; Gilliland, Ronald L.; Seager, Sara

    2015-01-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  6. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Désert, Jean-Michel; Brown, Timothy M. [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO 80309 (United States); Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bryson, Stephen T.; Borucki, William J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Batalha, Natalie M. [San Jose State University, San Jose, CA 95192 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Ford, Eric B. [University of Florida, Gainesville, FL 32611 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Gilliland, Ronald L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Seager, Sara, E-mail: desert@colorado.edu [Massachusetts Institute of Technology, Cambridge, MA 02159 (United States)

    2015-05-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  7. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    Science.gov (United States)

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  8. Scenario analysis of false indication in computer-control systems

    International Nuclear Information System (INIS)

    Tseng, Wan-Hui; Fan, Chin-Feng

    2013-01-01

    Highlights: ► A new failure mode and effect for safety-critical systems is proposed. ► False indication is the most dreadful kind of partial failures. ► A model-based simulation approach to generate failure scenarios is proposed. ► Simulation results showed that multiple errors may cause undesired consequences. ► An assertion-based method to detect false indication problems is provided. -- Abstract: Computer control may cause additional failure modes and effects that are new to analogue systems. False indication is one such failure mode that may bring unknown risks to a system. False indication refers to the problem when part of a system fails while other processes still work, and the failure is not revealed to operators. This paper presents a model-based simulation approach to systematically generate potential false indication and unintended consequences. Experiments showed that once a false indication occurs, it may have drastic effects on system safety. False indication can mislead the operator to perform adverse actions or no action. Therefore, we propose an assertion-based detection method to alleviate such failures. Our assertions contain process/device dependencies, timing relations and physical conservation rules. With these assertions, the operator may be alerted at run time. The proposed technique can reduce false indication problem. Moreover, it can also be used to assist the system design.

  9. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  10. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  11. 33 CFR 147.839 - Mad Dog Truss Spar Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Mad Dog Truss Spar Platform... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.839 Mad Dog Truss Spar Platform safety zone. (a) Description. Mad Dog Truss Spar Platform, Green Canyon 782 (GC 782), located at position...

  12. Closure of the condensed-phase organic-nitrate reaction unreviewed safety question at Hanford site

    International Nuclear Information System (INIS)

    COWLEY, W.L.

    1999-01-01

    A discovery Unreviewed Safety Question (USQ) was declared on the underground waste storage tanks at the Hanford Site in May 1996. The USQ was for condensed-phase organic-nitrate reactions (sometimes called organic complexant reactions) in the tanks. This paper outlines the steps taken to close the USQ, and resolve the related safety issue. Several processes were used at the Hanford Site to extract and/or process plutonium. These processes resulted in organic complexants (for chelating multivalent cations) and organic extraction solvents being sent to the underground waste storage tanks. This paper addresses the organic complexant hazard. The organic complexants are in waste matrices that include inert material, diluents, and potential oxidizers. In the presence of oxidizing material, the complexant salts can be made to react exothermically by heating to high temperatures or by applying an external ignition source of sufficient energy. The first organic complexant hazard assessments focused on determining whether a hulk runaway reaction could occur, similar to the 1957 accident at Kyshtm (a reprocessing plant in the former U.S.S.R.). Early analyses (1977 through 1994) examined organic-nitrate reaction onset temperatures and concluded that a bulk runaway reaction could not occur at the Hanford Site because tank temperatures were well below that necessary for bulk runaway. Therefore, it was believed that organic-nitrate reactions were adequately described in the then current Authorization Basis (AB). Subsequent studies examined a different accident scenario, propagation resulting from an external ignition source (e.g., lightning or welding slag) that initiates a combustion front that propagates through the organic waste. A USQ evaluation determined that localized high energy ignition sources were credible, and that point source ignition of organic complexant waste was not adequately addressed i n the then existing AB. Consequently, the USQ was declared on the

  13. Nuclear reaction models - source term estimation for safety design in accelerators

    International Nuclear Information System (INIS)

    Nandy, Maitreyee

    2013-01-01

    Accelerator driven subcritical system (ADSS) employs proton induced spallation reaction at a few GeV. Safety design of these systems involves source term estimation in two steps - multiple fragmentation of the target and n+γ emission through a fast process followed by statistical decay of the primary fragments. The prompt radiation field is estimated in the framework of quantum molecular dynamics (QMD) theory, intra-nuclear cascade or Monte Carlo calculations. A few nuclear reaction model codes used for this purpose are QMD, JQMD, Bertini, INCL4, PHITS, followed by statistical decay codes like ABLA, GEM, GEMINI, etc. In the case of electron accelerators photons and photoneutrons dominate the prompt radiation field. High energy photon yield through Bremsstrahlung is estimated in the framework of Born approximation while photoneutron production is calculated using giant dipole resonance and quasi-deuteron formation cross section. In this talk hybrid and exciton PEQ models and QMD formalism will be discussed briefly

  14. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    International Nuclear Information System (INIS)

    Ascunce, Nieves; Ederra, Maria; Delfrade, Josu; Erdozain, Nieves; Baroja, Araceli; Zubizarreta, Raquel; Salas, Dolores; Castells, Xavier

    2012-01-01

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  16. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    Energy Technology Data Exchange (ETDEWEB)

    Ascunce, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Instituto de Salud Publica, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Ederra, Maria; Delfrade, Josu; Erdozain, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Baroja, Araceli [Fundacion Rioja Salud, Logrono (Spain); Zubizarreta, Raquel [Public Health and Planning Directorate, Health Office, Galician Breast Cancer Screening Programme, Galicia (Spain); Salas, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Castells, Xavier [Mar Teaching Hospital, CIBERESP, Department of Clinical Epidemiology, Barcelona (Spain)

    2012-02-15

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  17. The uterine blush. A potential false-positive in Meckel's scan interpretation

    International Nuclear Information System (INIS)

    Fink-Bennett, D.

    1982-01-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations

  18. Combination of RNA- and exome-sequencing efficiently eliminates false-positive somatic point mutations and indels – exemplified by cases of CN-AML

    DEFF Research Database (Denmark)

    Herborg, Laura Laine; Hansen, Marcus Celik; Roug, Anne Stidsholt

    Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive observat......Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive...... in the workflow, not only provides information on malignant expression profiles excluded here, but importantly help to capture the, often very few somatic mutations of myeloid leukaemia....

  19. Technology Solutions Case Study: Combustion Safety Simplified Test Protocol

    Energy Technology Data Exchange (ETDEWEB)

    L. Brand, D. Cautley, D. Bohac, P. Francisco, L. Shen, and S. Gloss

    2015-12-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives.

  20. Occurrence of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae isolates.

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Adequate detection of the production of carbapenemase in Enterobacteriaceae isolates is crucial for infection control measures and the appropriate choice of antimicrobial therapy. In this study, we investigated the frequency of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae clinical isolates by the modified Hodge test (MHT. Three hundred and one E. coli and K. pneumoniae clinical isolates were investigated. All produced extended spectrum β-lactamases (ESBLs but were susceptible to carbapenems. Antimicrobial susceptibility testing was performed by the disk diffusion and agar dilution methods. The MHT was performed using the standard inoculum of test organisms recommended by the CLSI. Genes that encoded ESBLs and carbapenemases were identified by PCR and DNA sequencing. Among the 301 clinical isolates, none of the isolates conformed to the criteria for carbapenemase screening recommended by the CLSI. The susceptibility rates for imipenem, meropenem, and ertapenem all were 100.0%, 100.0%, and 100.0%, respectively. Of the 301 E. coli and K. pneumoniae isolates, none produced carbapenemase. The MHT gave a positive result for 3.3% (10/301 of the isolates. False positive results can occur when the MHT is used to detect carbapenemase in ESBL-producing isolates and clinical laboratories must be aware of this fact.

  1. Effects of positive electrical feedback in the oscillating Belousov-Zhabotinsky reaction: Experiments and simulations

    International Nuclear Information System (INIS)

    Sriram, K.

    2006-01-01

    This paper describes both the experimental and numerical investigations on the effect of positive electrical feedback in the oscillating Belovsou-Zhabotinsky (BZ) reaction under batch conditions. Positive electrical feedback causes an increase in the amplitude and period of the oscillations with the corresponding increase of the feedback strength. Oregonator model with a positive feedback term suitably incorporated in one of the dynamical variables is used to account for these experimental observations. Further, the effect of positive feedback on the Hopf points are investigated numerically by constructing the bifurcation diagrams. In the absence of feedback, for a particular stoichiometric parameter, the model exhibits both supercritical and subcritical Hopf bifurcations with canard existing near the former Hopf point. In the presence of positive feedback it is observed that (i) both the Hopf points advances, (ii) the distance between the two Hopf points decreases linearly, while the period increases exponentially with the increase of feedback strength near the Hopf points, (iii) only supercritical Hopf point without canard survives for a very strong positive feedback strength and (iv) moderate feedback strength takes the system away from limit cycle to the canard regime. These observations are explained in terms of Field-Koeroes-Noyes mechanism of the Belousov-Zhabotinsky reaction. This may be the first instance where the advancement of Hopf points due to positive feedback is clearly shown

  2. Working memory affects false memory production for emotional events.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  3. Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Armato, Samuel G. III; Li, Feng; Sone, Shusuke; Doi, Kunio

    2003-01-01

    In this study, we investigated a pattern-recognition technique based on an artificial neural network (ANN), which is called a massive training artificial neural network (MTANN), for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography (CT) images. The MTANN consists of a modified multilayer ANN, which is capable of operating on image data directly. The MTANN is trained by use of a large number of subregions extracted from input images together with the teacher images containing the distribution for the 'likelihood of being a nodule'. The output image is obtained by scanning an input image with the MTANN. The distinction between a nodule and a non-nodule is made by use of a score which is defined from the output image of the trained MTANN. In order to eliminate various types of non-nodules, we extended the capability of a single MTANN, and developed a multiple MTANN (Multi-MTANN). The Multi-MTANN consists of plural MTANNs that are arranged in parallel. Each MTANN is trained by using the same nodules, but with a different type of non-nodule. Each MTANN acts as an expert for a specific type of non-nodule, e.g., five different MTANNs were trained to distinguish nodules from various-sized vessels; four other MTANNs were applied to eliminate some other opacities. The outputs of the MTANNs were combined by using the logical AND operation such that each of the trained MTANNs eliminated none of the nodules, but removed the specific type of non-nodule with which the MTANN was trained, and thus removed various types of non-nodules. The Multi-MTANN consisting of nine MTANNs was trained with 10 typical nodules and 10 non-nodules representing each of nine different non-nodule types (90 training non-nodules overall) in a training set. The trained Multi-MTANN was applied to the reduction of false positives reported by our current computerized scheme for lung nodule detection based on a database of 63 low-dose CT scans (1765

  4. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    Science.gov (United States)

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  5. The semantics of emotion in false memory.

    Science.gov (United States)

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Effects of Fatigue on Driving Safety: A Comparison of Brake Reaction Times in Night Float and Postcall Physicians in Training.

    Science.gov (United States)

    Talusan, Paul G; Long, Theodore; Halim, Andrea; Guliani, Laura; Carroll, Nicole; Reach, John

    2014-12-01

    Concerns about duty hour and resident safety have fostered discussion about postshift fatigue and driving impairment. We assessed how converting to a night float schedule for overnight coverage affected driving safety for trainees. Brake reaction times were measured for internal medicine and orthopaedic surgery resident volunteers after a traditional 28-hour call shift and after a night float shift. We conducted matched paired t tests of preshift and postshift reaction time means. Participants also completed the Epworth Sleepiness Scale pre- and postshift. From June to July 2013, we enrolled 58 interns and residents (28 orthopaedic surgery, 30 internal medicine). We included 24 (41%) trainees on night float rotations and 34 (59%) trainees on traditional 28-hour call shifts. For all residents on night float rotations, there was no significant difference pre- and postshift. An increase in reaction times was noted among trainees on 28-hour call rotations. This included no effect on reaction times for internal medicine trainees pre- and postshift, and an increase in reaction times for orthopaedic trainees. For both night float and traditional call groups, there were significant increases in the Epworth Sleepiness Scale. Trainees on traditional 28-hour call rotations had significantly worse postshift brake reaction times, whereas trainees on night float rotations had no difference. Orthopaedic trainees had significant differences in brake reaction times after a traditional call shift.

  7. How does negative emotion cause false memories?

    Science.gov (United States)

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  8. False Memories for Affective Information in Schizophrenia.

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p  false memories ( p  > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  9. False Memories for Affective Information in Schizophrenia

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600

  10. Radiodine administration under suppression of TSH for identification of false positive receptions in patients with thyroid differentiated carcinoma (TDC): utility of the potassium perchlorate

    International Nuclear Information System (INIS)

    Santangelo, L.A.; Pitoia, F.; Sanz, C.; Niepomniszcze, H.; El Tamer, Elias

    2004-01-01

    The total body scan, after a dose of 131 I correlated with the measurement of stimulated Tg, constitute the principal pillars in follow-up of patients with TDC (thyroid differentiated carcinoma). A bibliographical search revealed more than 70 situations that can cause false total body scans positive. The examination is essential to avoid unnecessary treatment with radioiodine. The object is to evaluate the effectiveness of the radioiodine administration under hormonal therapy thyroid suppressive (THST) to eliminate the possibility of a false total body scan positive in five patients with TDC with stimulated Tg <1ng/ml

  11. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Positional stability test (roll-off resistance). 1203.15 Section 1203.15 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... over the helmet along the midsagittal plane and attaching the hook over the edge of the helmet as shown...

  12. Effects of depressive disorder on false memory for emotional information.

    Science.gov (United States)

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  13. Positional isotope exchange analysis of the uridine-diphosphoglucose pyrophosphorylase reaction

    International Nuclear Information System (INIS)

    Hester, L.; Hilscher, L.; Raushel, F.M.

    1986-01-01

    The enzyme uridine-diphosphoglucose pyrophosphorylase catalyzes the reversible formation of pyrophosphate and UDP-glucose from UTP and glc-1P. The positional isotope exchange reaction was measured using oxygen-18 labelled UTP. The synthesis of [β- 18 O 2 , βγ- 18 O, γ- 18 O 3 ]UTP was accomplished by the coupled activities of carbamate kinase, nucleoside diphosphate kinase, and nucleoside monophosphate kinase. The exchange of an oxygen-18 from a β-nonbridge position of the labelled UTP to the αβ-bridge position was measured with 31 P NMR. The ratio of the rate of net substrate turnover and the positional isotope exchange rate was measured as a function of the initial glc-1P concentration. This ratio was found to increase with an increasing concentration of glc-1P. The intercept at low glc-1P was found to be 1.2 and the slope was 4.5 mM -1 . These results have been interpreted to mean that this enzyme has an ordered addition of substrates. The lower limit for the release of pyrophosphate from E-UDPG-PP/sub i/ relative to V 2 is 1.2. The rate constant for the release of UTP from E-UTP relative to V 1 is 9

  14. Commuter Train Passenger Safety Model Using Positive Behavior Approach: The Case Study in Suburban Area

    Science.gov (United States)

    Suryanto, D. A.; Adisasmita, S. A.; Hamid, S.; Hustim, M.

    2018-04-01

    Currently, Train passanger safety measures are more predominantly measurable using negative dimensions in user mode behavior, such as accident rate, accident intensity and accident impact. This condition suggests that safety improvements aim only to reduce accidents. Therefore, this study aims to measure the safety level of light train transit modes (KRL) through the dimensions of traveling safety on commuters based on positive safety indicators with severel condition departure times and returns for work purposes and long trip rates above KRL. The primary survey were used in data collection methods. Structural Equation Modeling (SEM) were used in data analysis. The results show that there are different models of the safety level of departure and return journey. The highest difference is in the security dimension which is the internal variable of KRL users.

  15. Cloud/Fog Computing System Architecture and Key Technologies for South-North Water Transfer Project Safety

    Directory of Open Access Journals (Sweden)

    Yaoling Fan

    2018-01-01

    Full Text Available In view of the real-time and distributed features of Internet of Things (IoT safety system in water conservancy engineering, this study proposed a new safety system architecture for water conservancy engineering based on cloud/fog computing and put forward a method of data reliability detection for the false alarm caused by false abnormal data from the bottom sensors. Designed for the South-North Water Transfer Project (SNWTP, the architecture integrated project safety, water quality safety, and human safety. Using IoT devices, fog computing layer was constructed between cloud server and safety detection devices in water conservancy projects. Technologies such as real-time sensing, intelligent processing, and information interconnection were developed. Therefore, accurate forecasting, accurate positioning, and efficient management were implemented as required by safety prevention of the SNWTP, and safety protection of water conservancy projects was effectively improved, and intelligential water conservancy engineering was developed.

  16. Breast cancer risk is increased in the years following false-positive breast cancer screening.

    Science.gov (United States)

    Goossens, Mathijs C; De Brabander, Isabel; De Greve, Jacques; Vaes, Evelien; Van Ongeval, Chantal; Van Herck, Koen; Kellen, Eliane

    2017-09-01

    A small number of studies have investigated breast cancer (BC) risk among women with a history of false-positive recall (FPR) in BC screening, but none of them has used time-to-event analysis while at the same time quantifying the effect of false-negative diagnostic assessment (FNDA). FNDA occurs when screening detects BC, but this BC is missed on diagnostic assessment (DA). As a result of FNDA, screenings that detected cancer are incorrectly classified as FPR. Our study linked data recorded in the Flemish BC screening program (women aged 50-69 years) to data from the national cancer registry. We used Cox proportional hazards models on a retrospective cohort of 298 738 women to assess the association between FPR and subsequent BC, while adjusting for potential confounders. The mean follow-up was 6.9 years. Compared with women without recall, women with a history of FPR were at an increased risk of developing BC [hazard ratio=2.10 (95% confidence interval: 1.92-2.31)]. However, 22% of BC after FPR was due to FNDA. The hazard ratio dropped to 1.69 (95% confidence interval: 1.52-1.87) when FNDA was excluded. Women with FPR have a subsequently increased BC risk compared with women without recall. The risk is higher for women who have a FPR BI-RADS 4 or 5 compared with FPR BI-RADS 3. There is room for improvement of diagnostic assessment: 41% of the excess risk is explained by FNDA after baseline screening.

  17. Self-powered 'AND' logic circuit of dynamic type with positive safety and application of said 'AND' circuit

    International Nuclear Information System (INIS)

    Lefebvre, Claude; Therond, J.P.

    1974-01-01

    The present invention relates to a self-powered 'AND' logic circuit of dynamic type with positive safety, which delivers on duty operation an output signal equal to the logic product of the input logic signals. The invention relates also to the use of said 'AND' logic circuits in developing n/m logics also of dynamic types with positive safety, delivering on duty operation a zero valued signal when, at least n of the m input signals have the value zero. This type of logics can be inserted in nuclear reactor protection systems; when the value of the reactor operating physical characteristics go out of the safety margins, or true trouble affects 'AND' circuits the value of the output signal is zero, that triggers off the safety absorber drap, for instance [fr

  18. Proportion of false-positive lesions at interim and end-of-treatment FDG-PET in lymphoma as determined by histology: Systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com; Kwee, Thomas C.

    2016-11-15

    Purpose: To systematically review and meta-analyze the proportion of false-positive lesions at interim and end-of-treatment {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in lymphoma using biopsy as reference standard. Materials and methods: Medline was searched for original studies. Methodological quality of included studies was evaluated, and results were meta-analytically summarized using random effects (in case of interstudy heterogeneity [I{sup 2} ≤ 50%]) or fixed effects (in case of no interstudy heterogeneity [I{sup 2} > 50%]). Results: Eleven studies, comprising 139 patients who underwent biopsy of an FDG-avid lesion during or after completion of antilymphoma treatment, were included. Overall methodological quality was moderate. The proportion of false-positive results among all biopsied FDG-avid lesions at PET performed during of after completion of treatment ranged between 7.7% and 90.5% (the vast majority was due to inflammatory changes), with a weighted summary proportion (random effects, I{sup 2} = 75.7%) of 55.7% (95% confidence interval [CI]: 32.6–76.6%). There were no available studies on interim FDG-PET in Hodgkin lymphoma. The pooled summary false-positive proportions were 83.0% (95% CI: 72.0%–90.2%) for interim FDG-PET in non-Hodgkin lymphoma (fixed effects, I{sup 2} = 27.7%), 23.1% (95% CI: 4.7%–64.5%) for end-of-treatment FDG-PET in Hodgkin lymphoma (random effects; I{sup 2} = 67.1%), and 31.5% (95% CI: 3.9%–83.9%) for end-of-treatment FDG-PET in non-Hodgkin lymphoma (random effects, I{sup 2} = 68.3%). Conclusion: Both interim and end-of-treatment FDG-PET scans in patients with lymphoma suffer from a very high number of false-positive FDG-avid lesions. This finding, in combination with the previously reported high number of false-negative FGD-PET scans for residual disease detection, suggests that the role of interim and end-of-treatment FDG-PET should be reconsidered.

  19. Improved accuracy of cell surface shaving proteomics in Staphylococcus aureus using a false-positive control

    DEFF Research Database (Denmark)

    Solis, Nestor; Larsen, Martin Røssel; Cordwell, Stuart J

    2010-01-01

    Proteolytic treatment of intact bacterial cells is an ideal means for identifying surface-exposed peptide epitopes and has potential for the discovery of novel vaccine targets. Cell stability during such treatment, however, may become compromised and result in the release of intracellular proteins...... that complicate the final analysis. Staphylococcus aureus is a major human pathogen, causing community and hospital-acquired infections, and is a serious healthcare concern due to the increasing prevalence of multiple antibiotic resistances amongst clinical isolates. We employed a cell surface "shaving" technique...... to trypsin and three identified in the control. The use of a subtracted false-positive strategy improved enrichment of surface-exposed peptides in the trypsin data set to approximately 80% (124/155 peptides). Predominant surface proteins were those associated with methicillin resistance-surface protein SACOL...

  20. First positive reactions to cannabis constitute a priority risk factor for cannabis dependence.

    Science.gov (United States)

    Le Strat, Yann; Ramoz, Nicolas; Horwood, John; Falissard, Bruno; Hassler, Christine; Romo, Lucia; Choquet, Marie; Fergusson, David; Gorwood, Philip

    2009-10-01

    To assess the association between first reactions to cannabis and the risk of cannabis dependence. A cross-sectional population-based assessment in 2007. A campus in a French region (Champagne-Ardennes). A total of 1472 participants aged 18-21 years who reported at least one life-time cannabis consumption, of 3056 students who were screened initially [the Susceptibility Addiction Gene Environment (SAGE) study]. Positive and negative effects of first cannabis consumptions, present cannabis dependence and related risk factors were assessed through questionnaires.   The effects of first cannabis consumptions were associated dose-dependently with cannabis dependence at age 18-21 years, both according to the transversal approach of the SAGE study and to the prospective cohort of the Christchurch Health and Development Study (CHDS) assessed at the age of 25 years. Participants of the SAGE study who reported five positive effects of their first cannabis consumption had odds of life-time cannabis dependence that were 28.7 (95% confidence interval: 14.6-56.5) higher than those who reported no positive effects. This association remains significant after controlling for potentially confounding factors, including individual and familial variables. This study suggests an association between positive reactions to first cannabis uses and risk of life-time cannabis dependence, this variable having a central role among, and through, other risk factors. © 2009 The Authors. Journal compilation © 2009 Society for the Study of Addiction.

  1. Interim staff position on environmental qualification of safety-related electrical equipment: including staff responses to public comments. Regulatory report

    International Nuclear Information System (INIS)

    Szukiewicz, A.J.

    1981-07-01

    This document provides the NRC staff positions regarding selected areas of environmental qualification of safety-related electrical equipment, in the resolution of Unresolved Safety Issue A-24, 'Qualification of Class IE Safety-Related Equipment.' The positions herein are applicable to plants that are or will be in the construction permit (CP) or operating license (OL) review process and that are required to satisfy the requirements set forth in either the 1971 or the 1974 version of IEEE-323 standard

  2. Diagnostic capabilities of non-treponemal and treponemal reactions in the early forms of syphilis

    Directory of Open Access Journals (Sweden)

    Zakharov S.V.

    2017-12-01

    Full Text Available A comparative analysis of the sensitivity and specificity of immunoblotting against other non-treponemal and treponemal reactions was carried out in 215 patients with early forms of syphilis. A high diagnostic efficiency of immunoblotting in patients with early latent syphilis was established. It was found that only in case of primary syphilis, immunoblotting is inferior to Immunofluorescence reaction; this test can be used for differential diagnosis between hidden syphilis and false positive reactions to syphilis.

  3. Occupational health and safety considerations for women employed in core mining positions

    Directory of Open Access Journals (Sweden)

    Doret Botha

    2015-06-01

    Full Text Available Orientation: Despite various liberalisation and feminisation processes with regard to gender and sex roles, traditionalistic typologies, especially in terms of occupational roles, are seemingly very reluctant to disappear from relevant theoretical discourses, as well as in practice. One of the main issues remains the terrain of physical work. Although women all over the world have been involved in mining activities for centuries, the mining industry has not been an obvious career choice for women. In South Africa, new mining legislation aims to rectify previous inequalities and disadvantages in the mining sector and specifically provides for the inclusion of women in core mining activities. Although well intended, women’s involvement in the core business of mining also exposes them to the various hazards related to mine work. Research purpose: This research determined perceptions regarding the health and safety of women working in core mining positions. Motivation for the study: Currently there is a paucity of published data regarding health and safety challenges pertaining to women employed in the core business of mining. Method: Quantitative and qualitative research paradigms were used (mixed method research design. Quantitative data were collected by means of a structured questionnaire. Qualitative data were collected by means of individual interviews and group interviews. Main findings: From the literature review and the empirical findings it is evident that various factors (physical work capacity, anthropometry and body composition, personal protective equipment, treatment during pregnancy and security measures need to be considered to ensure the health and safety of women employed in core mining positions. Practical/managerial implications: It is evident from the research that exceptional attention should be given to the promotion of the health and safety of women working in the core business of mines to sustain their involvement in the

  4. Adverse reactions and other factors that impact subsequent blood donation visits.

    Science.gov (United States)

    Custer, Brian; Rios, Jorge A; Schlumpf, Karen; Kakaiya, Ram M; Gottschall, Jerome L; Wright, David J

    2012-01-01

    The importance of adverse reactions in terms of donor safety recently has received significant attention, but their role in subsequent donation behavior has not been thoroughly investigated. Six REDS-II blood centers provided data for this analysis. Summary minor and major adverse reaction categories were created. The influence of adverse reactions on donation was examined in two ways: Kaplan-Meier curves were generated to determine the cumulative pattern of first return, and adjusted odds ratios (AORs) for demographic and other factors positively and negatively associated with return were estimated using multivariable logistic regression. Donors who had major reactions had longer times to return than donors with minor or no reactions. The AOR of returning for donors with major reactions was 0.32 (95% confidence interval [CI], 0.28-0.37) and with minor reactions 0.59 (95% CI, 0.56-0.62) when compared to donors who did not have reactions. Conversely, the most important factors positively associated with return were the number of donations in the previous year and increasing age. Subsequent return, whether a major, minor, or no reaction occurred, varied by blood center. Factors that are associated with the risk of having adverse reactions were not substantial influences on the return after adverse reactions. Having an adverse reaction leads to significantly lower odds of subsequent donation irrespective of previous donation history. Factors that have been associated with a greater risk of adverse reactions were not important positive or negative predictors of return after a reaction. © 2011 American Association of Blood Banks.

  5. The False Premises and False Promises of the Movement to Privatize Public Education.

    Science.gov (United States)

    Hawley, Willis D.

    1995-01-01

    Argues that the movement to provide parents with financial incentives to send students to private schools will increase the racial, ethnic, and socioeconomic homogeneity of American schools. Six common assumptions about the positive effects of privatizing education are examined and deemed false. Probable costs of tuition vouchers for private…

  6. Emotions and false memories: valence or arousal?

    Science.gov (United States)

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  7. False positive results using calcitonin as a screening method for medullary thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Rafael Loch Batista

    2013-01-01

    Full Text Available The role of serum calcitonin as part of the evaluation of thyroid nodules has been widely discussed in literature. However there still is no consensus of measurement of calcitonin in the initial evaluation of a patient with thyroid nodule. Problems concerning cost-benefit, lab methods, false positive and low prevalence of medullary thyroid carcinoma (MTC are factors that limit this approach. We have illustrated two cases where serum calcitonin was used in the evaluation of thyroid nodule and rates proved to be high. A stimulation test was performed, using calcium as secretagogue, and calcitonin hyper-stimulation was confirmed, but anatomopathologic examination did not evidence medullar neoplasia. Anatomopathologic diagnosis detected Hashimoto thyroiditis in one case and adenomatous goiter plus an occult papillary thyroid carcinoma in the other one. Recommendation for routine use of serum calcitonin in the initial diagnostic evaluation of a thyroid nodule, followed by a confirming stimulation test if basal serum calcitonin is showed to be high, is the most currently recommended approach, but questions concerning cost-benefit and possibility of diagnosis error make the validity of this recommendation discussible.

  8. False memories for affective information in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Beth Fairfield

    2016-11-01

    Full Text Available Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the-to-be-remembered material and false memory occurrence has not yet been studied. In this study, twenty-four patients and twenty-four healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p0.05 resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e. neutral episodes yielded a higher degree of errors than positive and negative episodes. Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  9. A Theory of False Cognitive Expectancies in Airline Pilots

    Science.gov (United States)

    Cortes, Antonio I.

    The Theory of False Cognitive Expectancies was developed by studying high reliability flight operations. Airline pilots depend extensively on cognitive expectancies to perceive, understand, and predict actions and events. Out of 1,363 incident reports submitted by airline pilots to the National Aeronautics and Space Administration Aviation Safety Reporting System over a year's time, 110 reports were found to contain evidence of 127 false cognitive expectancies in pilots. A comprehensive taxonomy was developed with six categories of interest. The dataset of 127 false expectancies was used to initially code tentative taxon values for each category. Intermediate coding through constant comparative analysis completed the taxonomy. The taxonomy was used for the advanced coding of chronological context-dependent visualizations of expectancy factors, known as strands, which depict the major factors in the creation and propagation of each expectancy. Strands were mapped into common networks to detect highly represented expectancy processes. Theoretical integration established 11 sources of false expectancies, the most common expectancy errors, and those conspicuous factors worthy of future study. The most prevalent source of false cognitive expectancies within the dataset was determined to be unconscious individual modeling based on past events. Integrative analyses also revealed relationships between expectancies and flight deck automation, unresolved discrepancies, and levels of situation awareness. Particularly noteworthy were the findings that false expectancies can combine in three possible permutations to diminish situation awareness and examples of how false expectancies can be unwittingly transmitted from one person to another. The theory resulting from this research can enhance the error coding process used during aircraft line oriented safety audits, lays the foundation for developing expectancy management training programs, and will allow researchers to proffer

  10. Reducing false asystole alarms in intensive care.

    Science.gov (United States)

    Dekimpe, Remi; Heldt, Thomas

    2017-07-01

    High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.

  11. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  12. Next-generation sequencing indicates false-positive MRD results and better predicts prognosis after SCT in patients with childhood ALL.

    Science.gov (United States)

    Kotrova, M; van der Velden, V H J; van Dongen, J J M; Formankova, R; Sedlacek, P; Brüggemann, M; Zuna, J; Stary, J; Trka, J; Fronkova, E

    2017-07-01

    Minimal residual disease (MRD) monitoring via quantitative PCR (qPCR) detection of Ag receptor gene rearrangements has been the most sensitive method for predicting prognosis and making post-transplant treatment decisions for patients with ALL. Despite the broad clinical usefulness and standardization of this method, we and others have repeatedly reported the possibility of false-positive MRD results caused by massive B-lymphocyte regeneration after stem cell transplantation (SCT). Next-generation sequencing (NGS) enables precise and sensitive detection of multiple Ag receptor rearrangements, thus providing a more specific readout compared to qPCR. We investigated two cohorts of children with ALL who underwent SCT (30 patients and 228 samples). The first cohort consisted of 17 patients who remained in long-term CR after SCT despite having low MRD positivity (SCT monitoring using qPCR. Only one of 27 qPCR-positive samples was confirmed to be positive by NGS. Conversely, 10 of 15 samples with low qPCR-detected MRD positivity from 13 patients who subsequently relapsed were also confirmed to be positive by NGS (P=0.002). These data show that NGS has a better specificity in post-SCT ALL management and indicate that treatment interventions aimed at reverting impending relapse should not be based on qPCR only.

  13. Myositis ossificans: a false positive of malignancy in PET - CT F.D.G. and in osseous scintigraphy with HMDP 99Tc

    International Nuclear Information System (INIS)

    Hassler, S.; Bourahla, K.

    2010-01-01

    Myositis ossificans is a difficult differential diagnosis and a false positive for malignancy in both 99m Tc H.M.D.P. (hydroxy-methylene diphosphonate) scintigraphy and in exploration PET-F.D.G. This hypothesis should be mentioned in case of young patients, despite the unusual scintigraphic appearance in a benign process. (N.C.)

  14. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  15. Randomized controlled trial of false safety behavior elimination therapy: a unified cognitive behavioral treatment for anxiety psychopathology.

    Science.gov (United States)

    Schmidt, Norman B; Buckner, Julia D; Pusser, Andrea; Woolaway-Bickel, Kelly; Preston, Jennifer L; Norr, Aaron

    2012-09-01

    We tested the efficacy of a unified cognitive-behavioral therapy protocol for anxiety disorders. This group treatment protocol, termed false safety behavior elimination therapy (F-SET), is a cognitive-behavioral approach designed for use across various anxiety disorders such as panic disorder (PD), social anxiety disorder (SAD), and generalized anxiety disorder (GAD). F-SET simplifies, as well as broadens, key therapeutic elements of empirically validated treatments for anxiety disorders to allow for easier delivery to heterogeneous groups of patients with anxiety psychopathology. Patients with a primary anxiety disorder diagnosis (N=96) were randomly assigned to F-SET or a wait-list control. Data indicate that F-SET shows good efficacy and durability when delivered to mixed groups of patients with anxieties (i.e., PD, SAD, GAD) by relatively inexperienced clinicians. Findings are discussed in the context of balancing treatment efficacy and clinical utility. Copyright © 2012. Published by Elsevier Ltd.

  16. ADVERSE REACTIONS TO VACCINES AND WAYS OF ITS PREVENTION

    Directory of Open Access Journals (Sweden)

    Yelyseyeva I. V

    2011-04-01

    Full Text Available The overview concerns allergic reaction on vaccines and possible ways of increasing safety of immunization on basis of use of local specific immunotherapies (SIT experience, particularly the sublingual route. The use of chemically altered allergens, allergoids; alternative routes of administration, particularly the sublingual route; use of novel adjuvants, such as CpG oligonucleotides and mycobacterial vaccines; other approaches, such as allergenic peptides, relevant T-cell epitope peptide immunotherapy; DNA vaccination, recombinant and engineered allergens, chimeric molecules and combined therapy are all approaches that have yielded positive results to increase safety of SIT and improve its efficacy.

  17. Too Good to be False : Nonsignificant Results Revisited

    NARCIS (Netherlands)

    Hartgerink, Chris H J; Wicherts, Jelte M.; Van Assen, M. A. L. M.

    2017-01-01

    Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST) is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant

  18. False Positive Findings on I-131 WBS and SPECT/CT in Patients with History of Thyroid Cancer: Case Series

    Directory of Open Access Journals (Sweden)

    Zeina C. Hannoush

    2017-01-01

    Full Text Available Introduction. Although whole body scan (WBS with I-131 is a highly sensitive tool for detecting normal thyroid tissue and metastasis of differentiated thyroid cancer (DTC, it is not specific. Additional information, provided by single photon emission computed tomography combined with X-ray computed tomography (SPECT/CT and by the serum thyroglobulin level, is extremely useful for the interpretation of findings. Case Presentation. We report four cases of false positive WBS in patients with DTC: ovarian uptake corresponding to an endometrioma, scrotal uptake due to a spermatocele, rib-cage uptake due to an old fracture, and hepatic and renal uptake secondary to a granuloma and simple cyst, respectively. Conclusions. Trapping, organification, and storage of iodine are more prominent in thyroid tissue but not specific. Physiologic sodium-iodine symporter expression in other tissues explains some, but not all, of the WBS false positive cases. Other proposed etiologies are accumulation of radioiodine in inflamed organs, metabolism of radiodinated thyroid hormone, presence of radioiodine in body fluids, and contamination. In our cases nonthyroidal pathologies were suspected since the imaging findings were not corroborated by an elevated thyroglobulin level, which is considered a reliable tumor marker for most well-differentiated thyroid cancers. Clinicians should be aware of the potential pitfalls of WBS in DTC to avoid incorrect management.

  19. Case Report:False-negative HIV-1 polymerase chain reaction in a ...

    African Journals Online (AJOL)

    Polymerase chain reaction (PCR) testing is the gold standard for determining the HIV status in children <18 months of age. However, when clinical manifestations are not consistent with laboratory results, additional investigation is required. We report a 15-month-old HIV-exposed boy referred to our hospital after he had ...

  20. High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.

    Science.gov (United States)

    El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin

    2012-07-01

    Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.

  1. Safety assessment of Maillard reaction products of chicken bone hydrolysate using Sprague-Dawley rats

    Directory of Open Access Journals (Sweden)

    Jin-Zhi Wang

    2016-03-01

    Full Text Available Background: The Maillard reaction products of chicken bone hydrolysate (MRPB containing 38% protein, which is a derived product from chicken bone, is usually used as a flavor enhancer or food ingredient. In the face of a paucity of reported data regarding the safety profile of controversial Maillard reaction products, the potential health effects of MRPB were evaluated in a subchronic rodent feeding study. Methods: Sprague–Dawley rats (SD, 5/sex/group were administered diets containing 9, 3, 1, or 0% of MRPB derived from chicken bone for 13 weeks. Results: During the 13-week treatment period, no mortality occurred, and no remarkable changes in general condition and behavior were observed. The consumption of MRPB did not have any effect on body weight or feed and water consumption. At the same time, there was no significant increase in the weights of the heart, liver, lung, kidney, spleen, small intestine, and thymus in groups for both sexes. Serological examination showed serum alanine aminotransferase in both sexes was decreased significantly, indicating liver cell protection. No treatment-related histopathological differences were observed between the control and test groups. Conclusion: Based on the results of this study, the addition of 9% MRPB in the diet had no adverse effect on both male and female SD rats during the 90-day observation. Those results would provide useful information on the safety of a meaty flavor enhancer from bone residue as a byproduct of meat industry.

  2. The uterine blush. A potential false-positive in Meckel's scan interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fink-Bennett, D.

    1982-10-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.

  3. Analysis of ping-pong reaction mechanisms by positional isotope exchange. Application to galactose-1-phosphate uridyltransferase

    International Nuclear Information System (INIS)

    Hester, L.S.; Raushel, F.M.

    1987-01-01

    A new positional isotope exchange method has been developed that can be used for the analysis of enzyme-catalyzed reactions which have ping-pong kinetic mechanisms. The technique can be used to measure the relative rates of ligand dissociation from enzyme-product complexes. Enzyme is incubated with the labeled substrate and an excess of the corresponding unlabeled product. The partitioning of the enzyme-product complex back toward free enzyme is determined from the rate of positional isotope exchange within the original labeled substrate. The partitioning of the enzyme-product complex forward toward free enzyme is determined from the rate of formation of totally unlabeled substrate. It has been shown that the ratio of the two rates provides a lower limit for the release of product from the enzyme-product complex. The technique has been applied to the reaction catalyzed by galactose-1-phosphate uridyltransferase. The lower limit for the release of glucose 1-phosphate from the uridyl-enzyme relative to the maximal velocity of the reverse reaction was determined to be 3.4 +/- 0.5

  4. Trial sequential analysis reveals insufficient information size and potentially false positive results in many meta-analyses

    DEFF Research Database (Denmark)

    Brok, J.; Thorlund, K.; Gluud, C.

    2008-01-01

    in 80% (insufficient information size). TSA(15%) and TSA(LBHIS) found that 95% and 91% had absence of evidence. The remaining nonsignificant meta-analyses had evidence of lack of effect. CONCLUSION: TSA reveals insufficient information size and potentially false positive results in many meta......OBJECTIVES: To evaluate meta-analyses with trial sequential analysis (TSA). TSA adjusts for random error risk and provides the required number of participants (information size) in a meta-analysis. Meta-analyses not reaching information size are analyzed with trial sequential monitoring boundaries...... analogous to interim monitoring boundaries in a single trial. STUDY DESIGN AND SETTING: We applied TSA on meta-analyses performed in Cochrane Neonatal reviews. We calculated information sizes and monitoring boundaries with three different anticipated intervention effects of 30% relative risk reduction (TSA...

  5. The role of the Australian Adverse Drug Reactions Advisory Committee (ADRAC) in monitoring drug safety

    International Nuclear Information System (INIS)

    Boyd, Ian W.

    2002-01-01

    The Australian adverse drug reaction reporting system is acknowledged as one of the best in the world. Despite its small population of less than 20 million people, Australia's current ADR reporting rate of over 12000 reports per year places it in the top few nations in terms of reports per capita. The ADRAC program has been in operation for over 30 years. Australia was a founding member of the WHO International Drug Monitoring Programme which commenced in 1968 and currently there are about 153000 reports in the ADRAC database. Reports from health professionals have uncovered a number of significant safety problems over the years. Of particular importance are flucloxacillin-induced hepatitis, amoxycillin/clavulanate-induced hepatitis, and the association of cystitis with tiaprofenic acid. The number and quality of the reports has allowed an understanding of the characteristics of the reactions and, using ADRAC reporters as a major source of cases, case-control studies have been completed which have identified risk factors. ADRAC's review of Australian reports has highlighted many important associations that have been disseminated through the Australian Adverse Drug Reactions Bulletin

  6. Minimotif Miner 3.0: database expansion and significantly improved reduction of false-positive predictions from consensus sequences.

    Science.gov (United States)

    Mi, Tian; Merlin, Jerlin Camilus; Deverasetty, Sandeep; Gryk, Michael R; Bill, Travis J; Brooks, Andrew W; Lee, Logan Y; Rathnayake, Viraj; Ross, Christian A; Sargeant, David P; Strong, Christy L; Watts, Paula; Rajasekaran, Sanguthevar; Schiller, Martin R

    2012-01-01

    Minimotif Miner (MnM available at http://minimotifminer.org or http://mnm.engr.uconn.edu) is an online database for identifying new minimotifs in protein queries. Minimotifs are short contiguous peptide sequences that have a known function in at least one protein. Here we report the third release of the MnM database which has now grown 60-fold to approximately 300,000 minimotifs. Since short minimotifs are by their nature not very complex we also summarize a new set of false-positive filters and linear regression scoring that vastly enhance minimotif prediction accuracy on a test data set. This online database can be used to predict new functions in proteins and causes of disease.

  7. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension. Comparison with portographic findings of the pars umbilicus of the portal vein

    Energy Technology Data Exchange (ETDEWEB)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya [National Cancer Center, Tokyo (Japan). Hospital; Fukutake, Toshio

    1982-09-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH/sub 2/O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH/sub 2/O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered.

  8. MDEP Common Position No DICWG-09. Common position on safety design principles and supporting information for the overall I and C architecture

    International Nuclear Information System (INIS)

    2015-01-01

    The overall I and C architecture establishes the assignment of plant functions to individual I and C systems and the specification of the interface requirements of the individual I and C systems, including the layout of communications between individual I and C systems. Modern digital I and C (DI and C) is more integrated and performs more functions (e.g. self - tests, enhanced data communication) than did the earlier generations of I and C systems. This increased integration and functionality can contribute to more complexity. A well designed overall I and C architecture will ensure a proper implementation of the relevant safety principles (e.g. defense-in-depth concept) in order to ensure safe operation, and to facilitate the safety demonstration. The Digital Instrumentation and Controls Working Group (DICWG) has agreed that a common position on this topic is warranted given the increase of use of Digital I and C in new reactor designs, its safety implications, and the need to develop a common understanding from the perspectives of regulatory authorities. This action follows the DICWG examination of the regulatory requirements of the participating members and of relevant industry standards and IAEA documents. The DICWG proposes a common position based on its recent experience with the new reactor application reviews and operating plant issues

  9. Position-specific isotope modeling of organic micropollutants transformations through different reaction pathways

    Science.gov (United States)

    Jin, Biao; Rolle, Massimo

    2016-04-01

    Organic compounds are produced in vast quantities for industrial and agricultural use, as well as for human and animal healthcare [1]. These chemicals and their metabolites are frequently detected at trace levels in fresh water environments where they undergo degradation via different reaction pathways. Compound specific stable isotope analysis (CSIA) is a valuable tool to identify such degradation pathways in different environmental systems. Recent advances in analytical techniques have promoted the fast development and implementation of multi-element CSIA. However, quantitative frameworks to evaluate multi-element stable isotope data and incorporating mechanistic information on the degradation processes [2,3] are still lacking. In this study we propose a mechanism-based modeling approach to simultaneously evaluate concentration as well as bulk and position-specific multi-element isotope evolution during the transformation of organic micropollutants. The model explicitly simulates position-specific isotopologues for those atoms that experience isotope effects and, thereby, provides a mechanistic description of isotope fractionation occurring at different molecular positions. We validate the proposed approach with the concentration and multi-element isotope data of three selected organic micropollutants: dichlorobenzamide (BAM), isoproturon (IPU) and diclofenac (DCF). The model precisely captures the dual element isotope trends characteristic of different reaction pathways and their range of variation consistent with observed multi-element (C, N) bulk isotope fractionation. The proposed approach can also be used as a tool to explore transformation pathways in scenarios for which position-specific isotope data are not yet available. [1] Schwarzenbach, R.P., Egli, T., Hofstetter, T.B., von Gunten, U., Wehrli, B., 2010. Global Water Pollution and Human Health. Annu. Rev. Environ. Resour. doi:10.1146/annurev-environ-100809-125342. [2] Jin, B., Haderlein, S.B., Rolle, M

  10. Diagnostic capabilities of non-treponemal and treponemal reactions in the early forms of syphilis.

    OpenAIRE

    Zakharov, S. V.

    2017-01-01

    A comparative analysis of the sensitivity and specificity of immunoblotting against other non-treponemal and treponemal reactions was carried out in 215 patients with early forms of syphilis. A high diagnostic efficiency of immunoblotting in patients with early latent syphilis was established. It was found that only in case of primary syphilis, immunoblotting is inferior to Immunofluorescence reaction; this test can be used for differential diagnosis between hidden syphilis and false positive...

  11. Does Employee Safety Matter for Patients Too? Employee Safety Climate and Patient Safety Culture in Health Care.

    Science.gov (United States)

    Mohr, David C; Eaton, Jennifer Lipkowitz; McPhaul, Kathleen M; Hodgson, Michael J

    2015-04-22

    We examined relationships between employee safety climate and patient safety culture. Because employee safety may be a precondition for the development of patient safety, we hypothesized that employee safety culture would be strongly and positively related to patient safety culture. An employee safety climate survey was administered in 2010 and assessed employees' views and experiences of safety for employees. The patient safety survey administered in 2011 assessed the safety culture for patients. We performed Pearson correlations and multiple regression analysis to examine the relationships between a composite measure of employee safety with subdimensions of patient safety culture. The regression models controlled for size, geographic characteristics, and teaching affiliation. Analyses were conducted at the group level using data from 132 medical centers. Higher employee safety climate composite scores were positively associated with all 9 patient safety culture measures examined. Standardized multivariate regression coefficients ranged from 0.44 to 0.64. Medical facilities where staff have more positive perceptions of health care workplace safety climate tended to have more positive assessments of patient safety culture. This suggests that patient safety culture and employee safety climate could be mutually reinforcing, such that investments and improvements in one domain positively impacts the other. Further research is needed to better understand the nexus between health care employee and patient safety to generalize and act upon findings.

  12. Test analysis and research on static choice reaction ability of commercial vehicle drivers

    Science.gov (United States)

    Zhang, Lingchao; Wei, Lang; Qiao, Jie; Tian, Shun; Wang, Shengchang

    2017-03-01

    Drivers' choice reaction ability has a certain relation with safe driving. It has important significance to research its influence on traffic safety. Firstly, the paper uses a choice reaction detector developed by research group to detect drivers' choice reaction ability of commercial vehicles, and gets 2641 effective samples. Then by using mathematical statistics method, the paper founds that average reaction time from accident group has no difference with non-accident group, and then introduces a variance rate of reaction time as a new index to replace it. The result shows that the test index choice reaction errors and variance rate of reaction time have positive correlations with accidents. Finally, according to testing results of the detector, the paper formulates a detection threshold with four levels for helping transportation companies to assess commercial vehicles drivers.

  13. Suspected adverse drug reactions in elderly patients reported to the Committee on Safety of Medicines.

    OpenAIRE

    Castleden, C M; Pickles, H

    1988-01-01

    1. Spontaneous reports of suspected adverse drug reactions (ADRs) reported to the Committee on Safety of Medicines (CSM) have been studied in relation to patient age. 2. The proportion of reports received for the elderly increased between 1965 and 1983. 3. There was a correlation between the use of drugs and the number of ADR reports. Thus age-related prescription figures for two non-steroidal anti-inflammatory drugs (NSAI) and co-trimoxazole matched ADR reports for each drug in each age grou...

  14. Patient safety culture and leadership within Canada's Academic Health Science Centres: towards the development of a collaborative position paper.

    Science.gov (United States)

    Nicklin, Wendy; Mass, Heather; Affonso, Dyanne D; O'Connor, Patricia; Ferguson-Paré, Mary; Jeffs, Lianne; Tregunno, Deborah; White, Peggy

    2004-03-01

    Currently, the Academy of Canadian Executive Nurses (ACEN) is working with the Association of Canadian Academic Healthcare Organizations (ACAHO) to develop a joint position paper on patient safety cultures and leadership within Academic Health Science Centres (AHSCs). Pressures to improve patient safety within our healthcare system are gaining momentum daily. Because AHSCs in Canada are the key organizations that are positioned regionally and nationally, where service delivery is the platform for the education of future healthcare providers, and where the development of new knowledge and innovation through research occurs, leadership for patient safety logically must emanate from them. As a primer, ACEN provides an overview of current patient safety initiatives in AHSCs to date. In addition, the following six key areas for action are identified to ensure that AHSCs continue to be leaders in delivering quality, safe healthcare in Canada. These include: (1) strategic orientation to safety culture and quality improvement, (2) open and transparent disclosure policies, (3) health human resources integral to ensuring patient safety practices, (4) effective linkages between AHSCs and academic institutions, (5) national patient safety accountability initiatives and (6) collaborative team practice.

  15. Bifurcation of positive solutions to scalar reaction-diffusion equations with nonlinear boundary condition

    Science.gov (United States)

    Liu, Ping; Shi, Junping

    2018-01-01

    The bifurcation of non-trivial steady state solutions of a scalar reaction-diffusion equation with nonlinear boundary conditions is considered using several new abstract bifurcation theorems. The existence and stability of positive steady state solutions are proved using a unified approach. The general results are applied to a Laplace equation with nonlinear boundary condition and bistable nonlinearity, and an elliptic equation with superlinear nonlinearity and sublinear boundary conditions.

  16. Ferrocyanide Safety Project Dynamic X-Ray Diffraction studies of sodium nickel ferrocyanide reactions with equimolar nitrate/nitrite salts

    International Nuclear Information System (INIS)

    Dodds, J.N.; UNOCAL, Brea, CA

    1994-07-01

    Dynamic X-ray Diffraction (DXRD) has been to used to identify and quantify the solid state reactions that take place between sodium nickel ferrocyanide, Na 2 NiFe(CN) 6 , and equimolar concentrations of sodium nitrate/nitrite, reactions of interest to the continued environmental safety of several large underground waste storage tanks at the Hanford site in eastern Washington. The results are supportive of previous work, which indicated that endothermic dehydration and melting of the nitrates take place before the occurrence of exothermic reactions that being about 300 degrees C. The DXRD results show that a major reaction set at these temperatures is the occurrence of a series reaction that produces sodium cyanate, NaCNO, as an intermediate in a mildly exothermic first step. In the presence of gaseous oxygen, NaCNO subsequently reacts exothermally and at a faster rate to form metal oxides. Measurements of the rate of this reaction are used to estimate the heat release. Comparisons of this estimated heat release rate with heat transfer rates from a hypothetical ''hot spot'' show that, even in a worst-case scenario, the heat transfer rates are approximately eight times higher than the rate of energy release from the exothermic reactions

  17. Psychoactive drugs and false memory: comparison of dextroamphetamine and delta-9-tetrahydrocannabinol on false recognition

    Science.gov (United States)

    Ballard, Michael E.; Gallo, David A.; de Wit, Harriet

    2014-01-01

    Rationale Several psychoactive drugs are known to influence episodic memory. However, these drugs’ effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Objectives Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ9-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger–McDermott (DRM) illusion. Methods Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. Results As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs’ effects on true memory were positively correlated with their effects on false memory. Conclusions Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories. PMID:21647577

  18. Psychoactive drugs and false memory: comparison of dextroamphetamine and δ-9-tetrahydrocannabinol on false recognition.

    Science.gov (United States)

    Ballard, Michael E; Gallo, David A; de Wit, Harriet

    2012-01-01

    Several psychoactive drugs are known to influence episodic memory. However, these drugs' effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ(9)-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger-McDermott (DRM) illusion. Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs' effects on true memory were positively correlated with their effects on false memory. Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories.

  19. Crash safety concerns for out-of-position occupant postures: A look toward safety in highly automated vehicles.

    Science.gov (United States)

    McMurry, Timothy L; Poplin, Gerald S; Shaw, Greg; Panzer, Matthew B

    2018-04-09

    Highly automated vehicle occupants will all be passengers and may be free to ride while in postures for which existing occupant safety systems such as seat belts and airbags were not originally designed. These occupants could therefore face increased risk of injury when a crash occurs. Given that current vehicles are capable of supporting a variety of occupant postures outside of the normal design position, such as reclined or turned passengers, an evaluation of current field data was performed to better understand the risks of being out of position. We investigated the frequency, demographics, and injury outcomes for out-of-position occupants using NASS-CDS. A matched analysis was performed to compare injury outcomes for out-of-position passengers with in-position drivers involved in similar crashes. Finally, case studies for out-of-position occupants were examined in the Crash Injury Research (CIREN) database. Only 0.5% of occupants in NASS-CDS with a coded posture were out of position at the time of crash. Of the out-of-position occupants, being turned or seated sideways was almost as likely as being reclined. Out-of-position occupants were younger and less likely to be belted than their in-position counterparts. Analysis of the injury data indicated a trend that being out of position was associated with an elevated risk for serious injury. However, the number of out-of-position occupants was too small to provide a definitive or statistically significant conclusion on injury outcome. Though highly automated vehicles may eventually reduce the number of crashes and traffic fatalities in the future, there will be a transition period when these vehicles remain at risk from collisions with human-driven vehicles. These crashes could cause higher than anticipated rates of injury if occupants are less likely to be belted or tend to be in positions for which restraints are not optimized. This study highlights the need for future research on occupant response and

  20. Licensing of safety critical software for nuclear reactors. Common position of seven European nuclear regulators and authorised technical support organisations

    International Nuclear Information System (INIS)

    2010-01-01

    It is widely accepted that the assessment of software cannot be limited to verification and testing of the end product, i.e. the computer code. Other factors such as the quality of the processes and methods for specifying, designing and coding have an important impact on the implementation. Existing standards provide limited guidance on the regulatory and safety assessment of these factors. An undesirable consequence of this situation is that the licensing approaches taken by nuclear safety authorities and by technical support organisations are determined independently with only limited informal technical co-ordination and information exchange. It is notable that several software implementations of nuclear safety systems have been marred by costly delays caused by difficulties in co-ordinating the development and qualification process. It was thus felt necessary to compare the respective licensing approaches, to identify where a consensus already exists, and to see how greater consistency and more mutual acceptance could be introduced into current practices. This report is the result of the work of a group of regulator and safety authorities' experts. The 2007 version was completed at the invitation of the Western European Nuclear Regulators' Association (WENRA). The major result of the work is the identification of consensus and common technical positions on a set of important licensing issues raised by the design and operation of computer based systems used in nuclear power plants for the implementation of safety functions. The purpose is to introduce greater consistency and more mutual acceptance into current practices. To achieve these common positions, detailed consideration was paid to the licensing approaches followed in the different countries represented by the experts of the task force. The report is intended to be useful: - to coordinate regulators' and safety experts' technical viewpoints in the design of regulators' national policies and in revisions

  1. Licensing of safety critical software for nuclear reactors. Common position of seven European nuclear regulators and authorised technical support organisations

    Energy Technology Data Exchange (ETDEWEB)

    2010-07-01

    It is widely accepted that the assessment of software cannot be limited to verification and testing of the end product, i.e. the computer code. Other factors such as the quality of the processes and methods for specifying, designing and coding have an important impact on the implementation. Existing standards provide limited guidance on the regulatory and safety assessment of these factors. An undesirable consequence of this situation is that the licensing approaches taken by nuclear safety authorities and by technical support organisations are determined independently with only limited informal technical co-ordination and information exchange. It is notable that several software implementations of nuclear safety systems have been marred by costly delays caused by difficulties in co-ordinating the development and qualification process. It was thus felt necessary to compare the respective licensing approaches, to identify where a consensus already exists, and to see how greater consistency and more mutual acceptance could be introduced into current practices. This report is the result of the work of a group of regulator and safety authorities' experts. The 2007 version was completed at the invitation of the Western European Nuclear Regulators' Association (WENRA). The major result of the work is the identification of consensus and common technical positions on a set of important licensing issues raised by the design and operation of computer based systems used in nuclear power plants for the implementation of safety functions. The purpose is to introduce greater consistency and more mutual acceptance into current practices. To achieve these common positions, detailed consideration was paid to the licensing approaches followed in the different countries represented by the experts of the task force. The report is intended to be useful: - to coordinate regulators' and safety experts' technical viewpoints in the design of regulators' national

  2. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  3. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  4. An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening

    International Nuclear Information System (INIS)

    Nightingale, Julie M.; Borgen, Rita; Porter-Bennett, Lisa; Szczepura, Katy

    2015-01-01

    Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negative psychosocial consequences reported. Women are at increased relative risk of breast cancer therefore their attendance at subsequent screening is essential. Aims: To assess the impact of FP breast screening diagnosis and diagnostic work-up on re-attendance rates across four consecutive screening rounds at a typical breast screening centre. Method: Diagnostic interventions and screening re-attendance rates at one prior and two consecutive rounds were analysed for women receiving an FP diagnosis between 2004 and 2006. Results: 397 women (5.57%) were referred for further assessment, including 228 (57.43%) false positives. 34 eligible women failed to re-attend routine screening (+3 years), with 17 failing to re-attend subsequently (+6 years). 70.6% (24/34) of non-attenders had attended at least two screening rounds prior to FP assessment. 75% of FP women had an imaging-only assessment with 17.5% (30/171) failing to re-attend, and 25% received a biopsy, with 7% (4/57) failing to re-attend subsequently. Conclusion: This study is unique as it follows FP women through four consecutive screening rounds. FP non-attendance rates were considerably lower compared to the general screening population, with diagnostic work-up having limited influence. FP non-attendance may appear insignificant in comparison to total screened population, but these women are at greater risk of subsequent cancer so should be actively encouraged to re-engage with the screening programme

  5. Establishment of minimal positive-control conditions to ensure brain safety during rapid development of emergency vaccines.

    Science.gov (United States)

    Baek, Hyekyung; Kim, Kwang Ho; Park, Min Young; Kim, Kyeongryun; Ko, Bokyeong; Seo, Hyung Seok; Kim, Byoung Soo; Hahn, Tae-Wook; Yi, Sun Shin

    2017-08-31

    With the increase in international human and material exchanges, contagious and infectious epidemics are occurring. One of the effective methods of epidemic inhibition is the rapid development and supply of vaccines. Considering the safety of the brain during vaccine development is very important. However, manuals for brain safety assays for new vaccines are not uniform or effective globally. Therefore, the aim of this study is to establish a positive-control protocol for an effective brain safety test to enhance rapid vaccine development. The blood-brain barrier's tight junctions provide selective defense of the brain; however, it is possible to destroy these important microstructures by administering lipopolysaccharides (LPSs), thereby artificially increasing the permeability of brain parenchyma. In this study, test conditions are established so that the degree of brain penetration or brain destruction of newly developed vaccines can be quantitatively identified. The most effective conditions were suggested by measuring time-dependent expressions of tight junction biomarkers (zonula occludens-1 [ZO-1] and occludin) in two types of mice (C57BL/6 and ICR) following exposure to two types of LPS ( Salmonella and Escherichia ). In the future, we hope that use of the developed positive-control protocol will help speed up the determination of brain safety of novel vaccines.

  6. Affective valence influences participant's susceptibility to false memories and illusory recollection.

    Science.gov (United States)

    Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial

    2010-10-01

    This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  7. False positive of the scintigraphy with octreoscan: a diagnosis of elimination; Faux positif de la scintigraphie a l'octreoscan: un diagnostic d'elimination

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, N.; Brenot-Rossi, I.; Chuto, G.; Giovannini, M.; Delpero, J.R. [Institut Paoli-Calmettes, Marseille, (France)

    2009-05-15

    The imaging of receptors with somatostatin analogs by the pentetreotide-indium 111 (octreoscan) allows the detection of endocrine tumors essentially according to the density of S.S.T.2 receptors at the tumor level. The sensitivity of octreoscan for the detection of intestine endocrine tumors is included between 80 and 100% in the different studies. The clinical case presented here enlightens a case of false positive.We concluded to a physiological elimination of pentetreotide-indium 111 with intra pancreatic biliary stasis (perhaps a dysfunction of sphincter of ampulla of bile duct) and to the lack of tumor centre. It is here a diagnosis of elimination, supported by the different results of examination. all normal. This case of false positive induced expensive and traumatic explorations for the patient. (N.C.)

  8. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  9. Unique thermal record in False Bay

    CSIR Research Space (South Africa)

    Grundlingh, ML

    1993-10-01

    Full Text Available Over the past decade False Bay has assumed a prime position in terms of research in to large South African bays. This is manifested by investigations that cover flow conditions modelling, thermal structure, management, biology and nutrients, geology...

  10. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  11. Intellectual factors in false memories of patients with schizophrenia.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun

    2018-07-01

    The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Motivated reconstruction: The effect of brand commitment on false memories.

    Science.gov (United States)

    Montgomery, Nicole Votolato; Rajagopal, Priyali

    2018-06-01

    Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. Compensating for cross-reactions using avidity and computation in a suspension multiplex immunoassay for serotyping of Zika versus other flavivirus infections.

    Science.gov (United States)

    Rönnberg, Bengt; Gustafsson, Åke; Vapalahti, Olli; Emmerich, Petra; Lundkvist, Åke; Schmidt-Chanasit, Jonas; Blomberg, Jonas

    2017-10-01

    The recent spread of Zika virus (ZIKV) in the Americas and Asia necessitates an increased preparedness for improved maternal and perinatal health and blood safety. However, serological cross-reactions, especially to Dengue virus (DENV), complicate ZIKV antibody serodiagnosis. A novel "pan-Flavi" suspension multiplex immunoassay (PFSMIA) using 25 antigens, whole virus (WV), non-structural protein 1 (NS1), and envelope (E) proteins, from 7 zoonotic flaviviruses for specific detection of ZIKV and DENV IgM and IgG was developed. Patterns of antibody cross-reactivity, avidity, and kinetics were established in 104 sera from returning travelers with known ZIKV and DENV infections. PFSMIA gave IgM- and IgG-sensitivities for both viruses of 96-100%, compared to an immunofluorescence assay. Main IgM cross-reactions were to NS1, for IgG to the E and WV antigens. Infecting virus yielded reactivity to several antigens of the homologous virus, while cross-reactions tended to occur only to a single antigen from heterologous virus(es). A specificity-enhancing computer procedure took into account antibody isotype, number of antibody-reactive antigens per virus, avidity, average degree of cross-reactivity to heterologous flavivirus antigens, and reactivity changes in serial sera. It classified all 50 cases correctly. Applied to sera from 200 pregnant women and 173 blood donors from Sweden, one blood donor was found ZIKV NS1 IgM positive, and another as ZIKV NS1 IgG positive. These samples did not react with other ZIKV antigens and were thereby judged as false-positives. PFSMIA provided sensitive and specific ZIKV and DENV serology, warranting high-throughput serological surveillance and a minimized need for laborious and expensive virus neutralization assays.

  14. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  15. Neural Network Target Identification System for False Alarm Reduction

    Science.gov (United States)

    Ye, David; Edens, Weston; Lu, Thomas T.; Chao, Tien-Hsin

    2009-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

  16. Efficacy and safety of topical Trikatu preparation in, relieving mosquito bite reactions: a randomized controlled trial.

    Science.gov (United States)

    Maenthaisong, Ratree; Chaiyakunapruk, Nathorn; Tiyaboonchai, Waree; Tawatsin, Apiwat; Rojanawiwat, Archawin; Thavara, Usavadee

    2014-02-01

    Trikatu is composed of dried fruits of Piper nigrum L and Piper retrofractum Vahl, and dried rhizomes of Zingiber officinale R. Although this preparation has been used to relieve pruritis, pain, and inflammation for a long time, there is no clinical evidence to confirm its efficacy and safety. Therefore, we performed a double-blind, within person-randomized controlled study of 30 healthy volunteers to determine efficacy and safety of topical Trikatu on mosquito bite reactions. All subjects were bitten by Aedes aegypti laboratory mosquitoes on their forearms and they were randomly assigned arms to apply either Trikatu or reference product on the mosquito bite papule. The main outcome was the difference of papule size reduction at 30 min, measured by a caliper, between the Trikatu and reference arms. Pruritis, redness, pain, and patient satisfaction were assessed at 15, 30, 60, 180, and 360 min as secondary outcomes. There were no significant differences between treatment and reference arms on any outcome at any time of measurement. Trikatu did not show additional effects for relieving mosquito bite reaction as compared with the reference product containing camphor, menthol, and eucalyptus. For further study, it is very important to consider a proper selection of subjects, comparator product, and concentration of extract when Trikatu preparation is investigated. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. The Lifetime Economic Burden of Inaccurate HER2 Testing: Estimating the Costs of False-Positive and False-Negative HER2 Test Results in US Patients with Early-Stage Breast Cancer.

    Science.gov (United States)

    Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa

    2015-06-01

    Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. 14 CFR 1274.934 - Safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Safety. 1274.934 Section 1274.934... FIRMS Other Provisions and Special Conditions § 1274.934 Safety. Safety July 2002 NASA's safety priority... shall act responsibly in matters of safety and shall take all reasonable safety measures in performing...

  19. False-negative HIV-1 polymerase chain reaction in a 15-month-old ...

    African Journals Online (AJOL)

    Corresponding author: S Korsman (stephen.korsman@nhls.ac.za). Polymerase chain reaction (PCR) testing is the gold standard for determining the HIV status in children <18 months of age. ... mismatches relative to the consensus are shown as coloured blocks. Nucleic acid numbering relative to consensus C gag p24 is ...

  20. Effects of Maillard reaction on flavor and safety of Chinese traditional food: roast duck.

    Science.gov (United States)

    Zhou, Yiming; Xie, Fan; Zhou, Xiaoli; Wang, Yuqiang; Tang, Wen; Xiao, Ying

    2016-04-01

    Roast duck is one kind of representative roast food whose flavor is mainly produced by the Maillard reaction. However, some potentially toxic compounds are generated in the thermal process and are a potential health risk. The aim of this work was to analyze the effects of the Maillard reaction on flavor and safety of a Chinese traditional food: roast duck. Ducks with different roasting times (0, 10, 20, 30, 40, 50 and 60 min) were analyzed. The 40 and 50 min roast ducks exhibited an acceptable degree of sensory attributes, but the 60 min roast duck showed the most abundant aroma compounds. Antioxidant activities were observed to increase with roasting, and the 60 min roast duck showed the highest antioxidant activities (1,1-diphenylpicryhydrazyl, 39.3 µmol Trolox g(-1) sample). The highest content of acrylamide (0.21 µg g(-1)) and 5-hydroxymethylfurfural (0.089 µg g(-1)) were detected in the 50 and 60 min roast duck extract, respectively. Furthermore, water extract from 60 min roast ducks manifested a higher lactose dehydrogenase release ratio (51.9%) and greatly increased cell apoptosis. The drastic Maillard reaction in duck induced by long roasting time could be advantageous for color, aroma and antioxidant activities in roast ducks, but might be not beneficial to health. © 2015 Society of Chemical Industry.

  1. A step towards positive safety culture in DAE units

    International Nuclear Information System (INIS)

    Ramprasad, K.

    2016-01-01

    Department of Atomic Energy (DAE) has considered safety as its priority, since inception in late 1950s, in all its activities. A belief in safety principles like defense-in depth, diversity, multi-tier review, etc. has laid a long path of success in safety management for decades. Multitude of DAE activities in the past few decades, especially in application of nuclear energy in scientific research, industrial, medical, agriculture and food technologies, often, poses new challenges in safety management. A good safety management system is in place in DAE units to cope up with the challenges of the evolving technologies. An opportunity is taken through this workshop to highlight extra efforts to be taken to inch forward in developing a strong safety culture

  2. A study on sodium-concrete reaction

    Energy Technology Data Exchange (ETDEWEB)

    Pae, Jae Huem; Min, Byung Hoon; Lee, Joon Sik; Lee, Choong Hui; Chung, Ki Hong; Keum, Choong Ki [Suwon University, Suwon (Korea, Republic of)

    1994-07-15

    Sodium is commonly used as a coolant in liquid metal reactor. A large amount of its leakage may be possible in hypothetical accidents, even though the possibility is very low. In case that the leaked hot sodium comes in direct contact with structural concrete of liquid metal reactor, the reactor`s integrity can be challenged by the rupture of structure materials, hydrogen generation and its explosion, and release of radioactive aerosols due to sodium-concrete reaction. The knowledge of sodium-concrete reaction is evaluated to be one of the important and indispensable technologies for the establishment of safety measure in liquid metal reactor. In this study, the experimental facility of sodium-concrete reaction is to be designed, constructed and operated. And the reaction phenomena of sodium-concrete reaction is also to be analyzed through the experimental results. The aim of this study is to establish the measure of safety and protection for sodium-related facilities and to secure one of the fundamental technologies of liquid metal reactor safety. 47 refs., 7 figs., 13 tab.

  3. Suspected adverse drug reactions in elderly patients reported to the Committee on Safety of Medicines.

    Science.gov (United States)

    Castleden, C M; Pickles, H

    1988-10-01

    1. Spontaneous reports of suspected adverse drug reactions (ADRs) reported to the Committee on Safety of Medicines (CSM) have been studied in relation to patient age. 2. The proportion of reports received for the elderly increased between 1965 and 1983. 3. There was a correlation between the use of drugs and the number of ADR reports. Thus age-related prescription figures for two non-steroidal anti-inflammatory drugs (NSAI) and co-trimoxazole matched ADR reports for each drug in each age group. 4. The reported ADR was more likely to be serious or fatal in the elderly. 5. The commonest ADRs reported for the elderly affected the gastrointestinal (GIT) and haemopoietic systems, where more reports were received than would be expected from prescription figures. 6. The drug suspected of causing a GIT reaction was a NSAI in 75% of the reports. 7. Ninety-one per cent of fatal reports of GIT bleeds and perforations associated with NSAI drugs were in patients over 60 years of age.

  4. Arousal—But Not Valence—Reduces False Memories at Retrieval

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods–similar in arousal levels–correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval. PMID:26938737

  5. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Directory of Open Access Journals (Sweden)

    Chiara Mirandola

    Full Text Available Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1 whether valence and arousal equally affect false memory production, and (2 whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently, compared to individuals in neutral mood. This suggests that arousal (but not valence predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  6. Recursive belief manipulation and second-order false-beliefs

    DEFF Research Database (Denmark)

    Braüner, Torben; Blackburn, Patrick Rowan; Polyanskaya, Irina

    2016-01-01

    it indicate that a more fundamental *conceptual change* has taken place? In this paper we extend Braüner's hybrid-logical analysis of first-order false-belief tasks to the second-order case, and argue that our analysis supports a version of the conceptual change position.......The literature on first-order false-belief is extensive, but less is known about the second-order case. The ability to handle second-order false-beliefs correctly seems to mark a cognitively significant step, but what is its status? Is it an example of *complexity only* development, or does...

  7. LMFBR: safety aspects

    International Nuclear Information System (INIS)

    Natta, M.

    1990-01-01

    This presentation of LMFBR safety is limited at Super Phenix reactor. After a brief description of the reactor, some details on safety systems, in normal or accidental conditions, are given. The main functions studied are: chain reaction trip, residual power evacuation, reactor containment. In heavy accident the behaviour of Super Phenix is studied which its particular characteristics and the possibilities of operators reactions. The probability of appearance and the maximum consequences of heavy accidents are given [fr

  8. Underpowered samples, false negatives, and unconscious learning.

    Science.gov (United States)

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  9. MDEP Position Paper - PP-STC-01 - MDEP Steering Technical Committee Position Paper on Safety Goals

    International Nuclear Information System (INIS)

    2011-01-01

    In considering the acceptability of a nuclear facility in relation to safety, Governments and regulatory bodies define a range of legal, mandatory requirements which are supplemented by regulatory requirements and expectations which may not have a mandatory nature. The term 'safety goals' is used to cover all health and safety requirements and expectations which must be met: these may be deterministic rules and/or probabilistic targets. They should cover the safety of workers, public and the environment in line with the IAEA's Basic Safety Objective encompassing safety in normal operation through to severe plant states. Although all regulators have safety goals, these are expressed in many different ways and exercises in comparing them frequently are done at a very low level e.g. specific temperature limits in the reactor core. The differences in the requirements from different regulators are difficult to resolve as the goals are derived using different principles and assumptions and are usually for a specific technology. Therefore the Multinational Design Evaluation Programme (MDEP) set up a sub-committee to investigate a different approach. This approach was to start with the high level safety goals and try to derive a structure and means of deriving lower level safety goals that can be seen to be clearly related to the higher level ones. The work will greatly assist in the process of harmonisation of regulatory requirements and enhance coherence and consistency between goals for different technologies. MDEP expects that higher levels of safety will be achieved in the design and operation of new reactors. MDEP strongly supports the structure of safety goals and targets, as set out in this paper, for consideration of its members and IAEA and other organisations, in moving towards international harmonisation of regulatory requirements. MDEP strongly supports the use of integrated decision-making for design evaluation and operational safety. MDEP recognises the need

  10. A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

    CERN Document Server

    Pant, L M; Dinesh, B V; Thomas, R G; Saxena, A; Sawant, Y S; Choudhury, R K

    2002-01-01

    A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from sup 2 sup 4 sup 1 Am- sup 2 sup 3 sup 9 Pu source, fission fragments from sup 2 sup 5 sup 2 Cf and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed.

  11. Reaction path analysis of sodium-water reaction phenomena in support of chemical reaction model development

    International Nuclear Information System (INIS)

    Kikuchi, Shin; Ohshima, Hiroyuki; Hashimoto, Kenro

    2011-01-01

    Computational study of the sodium-water reaction at the gas (water) - liquid (sodium) interface has been carried out using ab initio (first-principle) method. A possible reaction channel has been identified for the stepwise OH bond dissociations of a single water molecule. The energetics including the binding energy of a water molecule to the sodium surface, the activation energies of the bond cleavages, and the reaction energies, have been evaluated, and the rate constants of the first and second OH bond-breakings have been compared. The results are used as the basis for constructing the chemical reaction model used in a multi-dimensional sodium-water reaction code, SERAPHIM, being developed by JAEA toward the safety assessment of the steam generator (SG) in a sodium-cooled fast reactor (SFR). (author)

  12. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    Science.gov (United States)

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  13. 49 CFR 385.317 - Will a safety audit result in a safety fitness determination by the FMCSA?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Will a safety audit result in a safety fitness... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES New Entrant Safety Assurance Program § 385.317 Will a safety audit result in a safety fitness determination by the FMCSA? A safety audit will not result in a safety...

  14. 14 CFR 1260.37 - Safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Safety. 1260.37 Section 1260.37 Aeronautics... Provisions § 1260.37 Safety. Safety October 2000 (a) The Recipient shall act responsibly in matters of safety and shall take all reasonable safety measures in performing under this grant or cooperative agreement...

  15. HAMS: High-Affinity Mass Spectrometry Screening. A High-Throughput Screening Method for Identifying the Tightest-Binding Lead Compounds for Target Proteins with No False Positive Identifications.

    Science.gov (United States)

    Imaduwage, Kasun P; Go, Eden P; Zhu, Zhikai; Desaire, Heather

    2016-11-01

    A major challenge in drug discovery is the identification of high affinity lead compounds that bind a particular target protein; these leads are typically identified by high throughput screens. Mass spectrometry has become a detection method of choice in drug screening assays because the target and the ligand need not be modified. Label-free assays are advantageous because they can be developed more rapidly than assays requiring labels, and they eliminate the risk of the label interfering with the binding event. However, in commonly used MS-based screening methods, detection of false positives is a major challenge. Here, we describe a detection strategy designed to eliminate false positives. In this approach, the protein and the ligands are incubated together, and the non-binders are separated for detection. Hits (protein binders) are not detectable by MS after incubation with the protein, but readily identifiable by MS when the target protein is not present in the incubation media. The assay was demonstrated using three different proteins and hundreds of non-inhibitors; no false positive hits were identified in any experiment. The assay can be tuned to select for ligands of a particular binding affinity by varying the quantity of protein used and the immobilization method. As examples, the method selectively detected inhibitors that have K i values of 0.2 μM, 50 pM, and 700 pM. These findings demonstrate that the approach described here compares favorably with traditional MS-based screening methods. Graphical Abstract ᅟ.

  16. The Safety and Efficacy of Adjustable Postoperative Position after Pars Plana Vitrectomy for Rhegmatogenous Retinal Detachment

    OpenAIRE

    Lin, Zhong; Sun, Jin Tao; Wu, Rong Han; Moonasar, Nived; Zhou, Ye Hui

    2017-01-01

    Purpose. To report the safety and efficacy of adjustable postoperative position for rhegmatogenous retinal detachment (RRD). Methods. Retrospective review of 536 consecutive RRD eyes that underwent vitrectomy surgery for retina repair from year 2008 to 2014. The retinal breaks were divided into superior, lateral (nasal, temporal, and macular), and inferior locations, according to the clock of breaks. Patients with superior and lateral break location were allowed to have facedown position or l...

  17. 14 CFR 417.109 - Ground safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Ground safety. 417.109 Section 417.109... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.109 Ground safety. (a) Ground safety... 417.115(c), and subpart E of this part provide launch operator ground safety requirements. ...

  18. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    Science.gov (United States)

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  19. False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.

    Science.gov (United States)

    Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed

    2017-10-01

    To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.

  20. Psychosocial safety climate buffers effects of job demands on depression and positive organizational behaviors.

    Science.gov (United States)

    Hall, Garry B; Dollard, Maureen F; Winefield, Anthony H; Dormann, Christian; Bakker, Arnold B

    2013-01-01

    In a general population sample of 2343 Australian workers from a wide ranging employment demographic, we extended research testing the buffering role of psychosocial safety climate (PSC) as a macro-level resource within the health impairment process of the Job Demands-Resources (JD-R) model. Moderated structural equation modeling was used to test PSC as a moderator between emotional and psychological job demands and worker depression compared with control and social support as alternative moderators. We also tested PSC as a moderator between depression and positive organizational behaviors (POB; engagement and job satisfaction) compared with control and social support as moderators. As expected we found PSC moderated the effects of job demands on depression and further moderated the effects of depression on POB with fit to the data that was as good as control and social support as moderators. This study has shown that PSC is a macro-level resource and safety signal for workers acting to reduce demand-induced depression. We conclude that organizations need to focus on the development of a robust PSC that will operate to buffer the effects of workplace psychosocial hazards and to build environments conducive to worker psychological health and positive organizational behaviors.

  1. Fuel Fracture (Crumbling) Safety Impact (OCRWM)

    International Nuclear Information System (INIS)

    DUNCAN, D.R.

    1999-01-01

    The safety impact of experimentally observed N Reactor fuel sample fracture and fragmentation is evaluated using an average reaction rate enhancement derived from data from thermo-gravimetric analysis (TGA) experiments on fuel samples. The enhanced reaction rates attributed to fragmentation were within the existing safety basis

  2. The role of nuclear reaction theory and data in nuclear energy and safety applications

    International Nuclear Information System (INIS)

    Schmidt, J.J.

    1993-01-01

    The nuclear data requirements for nuclear fission reactor design and safety computations are so large that they cannot be satisfied by experimental measurements alone. Nuclear reaction theories and models have recently been developed and refined to the extent, that, with suitable parametrisation and fitting to accurately known experimental data, they can be used for filling gaps in the available experimental nuclear data base as well as for bulk computations of nuclear reaction, e.g. activation cross sections. The concurrent rapid development of ever more powerful mainframe and personal computers has stimulated the development of comprehensive nuclear model computer codes. A representative selection of such codes will be presented in the lectures and computer exercises of this Workshop. In order to fulfill nuclear data requirements of the nineties and, at the same time, develop improved tools for nuclear physics teaching at developing country universities it will be required and a major future task of the IAEA nuclear data programme to develop computer files of ''best'' sets of nuclear parameters for standardised input to nuclear model computations of nuclear data. Nuclear scientists from developing countries can make substantial contributions to this project. (author). 25 refs

  3. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    Science.gov (United States)

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  5. Reactions to the glass cliff - Gender differences in the explanations for the precariousness of women's leadership positions

    NARCIS (Netherlands)

    Ryan, M.K.; Haslam, S.A.; Postmes, T.

    2007-01-01

    Purpose - This paper aims to investigate the phenomenon of the glass cliff, whereby women are more likely than men to be placed in precarious leadership positions. Men's and women's reactions to this subtle form of gender discrimination are examined, the identity processes involved, and the

  6. 14 CFR 417.107 - Flight safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety. 417.107 Section 417.107... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.107 Flight safety. (a) Flight safety... safety system that satisfies subpart D of this part as follows, unless § 417.125 applies. (1) In the...

  7. Mood-congruent true and false memory: effects of depression.

    Science.gov (United States)

    Howe, Mark L; Malone, Catherine

    2011-02-01

    The Deese/Roediger-McDermott paradigm was used to investigate the effect of depression on true and false recognition. In this experiment true and false recognition was examined across positive, neutral, negative, and depression-relevant lists for individuals with and without a diagnosis of major depressive disorder. Results showed that participants with major depressive disorder falsely recognised significantly more depression-relevant words than non-depressed controls. These findings also parallel recent research using recall instead of recognition and show that there are clear mood congruence effects for depression on false memory performance. © 2011 Psychology Press, an imprint of the Taylor & Francis Group, an Informa business

  8. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a...

  9. False recognition in behavioural variant frontotemporal dementia and Alzheimer’s disease – disinhibition or amnesia?

    Directory of Open Access Journals (Sweden)

    Emma C Flanagan

    2016-07-01

    Full Text Available Episodic memory recall processes in Alzheimer’s disease (AD and behavioural variant frontotemporal dementia (bvFTD can be similarly impaired, whereas recognition performance is more variable. A potential reason for this variability could be false-positive errors made on recognition trials and whether these errors are due to amnesia per se or a general over-endorsement of recognition items regardless of memory. The current study addressed this issue by analysing recognition performance on the Rey Auditory Verbal Learning Test (RAVLT in 39 bvFTD, 77 AD and 61 control participants from two centres (India, Australia, as well as disinhibition assessed using the Hayling test. Whereas both AD and bvFTD patients were comparably impaired on delayed recall, bvFTD patients showed intact recognition performance in terms of the number of correct hits. However, both patient groups endorsed significantly more false-positives than controls, and bvFTD and AD patients scored equally poorly on a sensitivity index (correct hits - false-positives. Furthermore, measures of disinhibition were significantly associated with false positives in both groups, with a stronger relationship with false-positives in bvFTD. Voxel-based morphometry analyses revealed similar neural correlates of false positive endorsement across bvFTD and AD, with both patient groups showing involvement of prefrontal and Papez circuitry regions, such as medial temporal and thalamic regions, and a DTI analysis detected an emerging but non-significant trend between false positives and decreased fornix integrity in bvFTD only. These findings suggest that false-positive errors on recognition tests relate to similar mechanisms in bvFTD and AD, reflecting deficits in episodic memory processes and disinhibition. These findings highlight that current memory tests are not sufficient to accurately distinguish between bvFTD and AD patients.

  10. Disfluent presentations lead to the creation of more false memories.

    Science.gov (United States)

    Sanchez, Christopher A; Naylor, Jamie S

    2018-01-01

    The creation of false memories within the Deese-Roediger-McDermott (DRM) paradigm has been shown to be sensitive to many factors such as task instructions, participant mood, or even presentation modality. However, do other simple perceptual differences also impact performance on the DRM and the creation of false memories? This study explores the potential impact of changes in perceptual disfluency on DRM performance. To test for a potential influence of disfluency on false memory creation, participants viewed lists under either perceptually disfluent conditions or not. Results indicated that disfluency did significantly impact performance in the DRM paradigm; more disfluent presentations significantly increased the recall and recognition of unpresented information, although they did not impact recall or recognition of presented information. Thus, although disfluency did impact performance, disfluency did not produce a positive benefit related to overall task performance. This finding instead suggests that more disfluent presentations can increase the likelihood that false memories are created, and provide little positive performance benefit.

  11. 33 CFR 165.20 - Safety zones.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety zones. 165.20 Section 165... WATERWAYS SAFETY REGULATED NAVIGATION AREAS AND LIMITED ACCESS AREAS Safety Zones § 165.20 Safety zones. A Safety Zone is a water area, shore area, or water and shore area to which, for safety or environmental...

  12. 48 CFR 923.7001 - Nuclear safety.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Nuclear safety. 923.7001... ENVIRONMENT, CONSERVATION, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Environmental, Energy and Water Efficiency, Renewable Energy Technologies, and Occupational Safety Programs 923.7001 Nuclear safety. The DOE...

  13. Yersinia enterocolitica: an unlikely cause of positive brucellosis tests in greater yellowstone ecosystem bison (Bison bison).

    Science.gov (United States)

    See, Wade; Edwards, William H; Dauwalter, Stacey; Almendra, Claudia; Kardos, Martin D; Lowell, Jennifer L; Wallen, Rick; Cain, Steven L; Holben, William E; Luikart, Gordon

    2012-07-01

    Yersinia enterocolitica serotype O:9 has identical O-antigens to those of Brucella abortus and has apparently caused false-positive reactions in numerous brucellosis serologic tests in elk (Cervus canadensis) from southwest Montana. We investigated whether a similar phenomenon was occurring in brucellosis antibody-positive bison (Bison bison) using Y. enterocolitica culturing techniques and multiplex PCR of four diagnostic loci. Feces from 53 Yellowstone bison culled from the population and 113 free-roaming bison from throughout the Greater Yellowstone Ecosystem (GYE) were tested. Yersinia enterocolitica O:9 was not detected in any of 53 the bison samples collected at slaughter facilities or in any of the 113 fecal samples from free-ranging bison. One other Y. enterocolitica serotype was isolated; however, it is not known to cause cross-reaction on B. abortus serologic assays because it lacks the perosamine synthetase gene and thus the O-antigens. These findings suggest that Y. enterocolitica O:9 cross-reactivity with B. abortus antigens is unlikely to have been a cause of false-positive serology tests in GYE bison and that Y. enterocolitica prevalence was low in bison in the GYE during this study.

  14. The effect of addition of primary positive salts, complex salt, on the ionic strength and rate constant at various temperatures by reaction kinetics

    Science.gov (United States)

    Kurade, S. S.; Ramteke, A. A.

    2018-05-01

    In this work, we have investigated the rate of reaction by using ionic strength at different temperatures. The main goal of this experiment is to determine the relation between ionic strength with reaction rate, reaction time and rate constant with temperature. It is observed that the addition of positive salt indicate the increasing ionic strength with increase in run time at various temperatures. Thus the temperature affects the speed of reaction and mechanism by which chemical reaction occurs and time variable plays vital role in the progress of reaction at different temperatures.

  15. Computational investigation of kinetics of cross-linking reactions in proteins: importance in structure prediction.

    Science.gov (United States)

    Bandyopadhyay, Pradipta; Kuntz, Irwin D

    2009-01-01

    The determination of protein structure using distance constraints is a new and promising field of study. One implementation involves attaching residues of a protein using a cross-linking agent, followed by protease digestion, analysis of the resulting peptides by mass spectroscopy, and finally sequence threading to detect the protein folds. In the present work, we carry out computational modeling of the kinetics of cross-linking reactions in proteins using the master equation approach. The rate constants of the cross-linking reactions are estimated using the pKas and the solvent-accessible surface areas of the residues involved. This model is tested with fibroblast growth factor (FGF) and cytochrome C. It is consistent with the initial experimental rate data for individual lysine residues for cytochrome C. Our model captures all observed cross-links for FGF and almost 90% of the observed cross-links for cytochrome C, although it also predicts cross-links that were not observed experimentally (false positives). However, the analysis of the false positive results is complicated by the fact that experimental detection of cross-links can be difficult and may depend on specific experimental conditions such as pH, ionic strength. Receiver operator characteristic plots showed that our model does a good job in predicting the observed cross-links. Molecular dynamics simulations showed that for cytochrome C, in general, the two lysines come closer for the observed cross-links as compared to the false positive ones. For FGF, no such clear pattern exists. The kinetic model and MD simulation can be used to study proposed cross-linking protocols.

  16. Individual case safety reports--how to determine the onset date of an adverse reaction: a survey.

    Science.gov (United States)

    Klepper, Michael J; Edwards, Brian

    2011-04-01

    The building blocks of a pharmacovigilance system depend primarily on good quality individual case safety reports (ICSRs), which are stand-alone summaries describing one or more suspected adverse reactions that occur while a subject is taking either an investigational or marketed medicinal product and may require expedited reporting to regulatory authorities. For regulatory reporting purposes, the information of an ICSR is usually captured on forms such as MedWatch 3500/3500A, CIOMS I, Vaccine Adverse Event Report System (VAERS) or Adverse Events Following Immunization (AEFI). ICSRs that are sent electronically must meet the standards for electronic transmission specified in the International Conference on Harmonisation (ICH) E2B (R2) guideline. In filling out these regulatory forms, there are some areas of ambiguity. One of these is what the 'date of event' (MedWatch) or 'reaction onset date' (CIOMS) is interpreted to be. The aim of the survey was to determine the uniformity of responses for the onset date of an adverse reaction. A pilot and three surveys of pharmacovigilance professionals were undertaken between February and July 2009 to determine the range of responses for the onset of an adverse reaction. A narrative of a subject admitted to hospital with a diagnosis of pneumonia was presented and the respondent was asked to pick the date of onset of the adverse reaction. The total number of respondents was 129. The results of the surveys indicated there was considerable variation in responses. These differences were based on different perspectives regarding the suspected adverse reaction. Some viewed the 'reaction' to be the first onset of signs and symptoms (even if non-specific), others considered the onset of the reaction to be the date of the diagnosis, while others considered the date to be when the reaction became serious. By means of a survey, we have illustrated an example of the variability of determining the onset date of a suspected adverse reaction

  17. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  18. The effect of mood on false memory for emotional DRM word lists.

    Science.gov (United States)

    Zhang, Weiwei; Gross, Julien; Hayne, Harlene

    2017-04-01

    In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.

  19. Voting experiments: Bandwagon voting or false-consensus effect?

    OpenAIRE

    Ivo Bischoff; Henrik Egbert

    2008-01-01

    In an experiment designed to test for expressive voting, Tyran (JPubEc 2004) found a strong positive correlation between the participants' approval for a proposal to donate money for charity and their expected approval rate for fellow voters. This phenomenon can be due to bandwagon voting or a false consensus effect. The social science literature reports both effects for voting decisions. Replicating Tyran's experiment and adding new treatments, we provide evidence for a false consensus effec...

  20. Early detection of typhoid by polymerase chain reaction

    International Nuclear Information System (INIS)

    Haque, A.; Qureshi, Javed A.; Ahmed, J.

    1999-01-01

    Typhoid is a common problem in developing countries. Cultivation ofbacteria and serology (especially Widal test) gives unacceptable levels offalse-negative and false-positive results respectively. In this study, arecently introduced polymerase chain reaction based technique (which has 100%specificity for Salmonella typhi) was compared with blood culture and Widaltest during the first week of illness of 82 suspected cases of typhoid. Therespective figures of positivity for PCR, blood culture and Widal test were71.95%, 34.1% and 36.5%. A control group of 20 healthy persons gave figuresof 0%, 0% and 33.3%, respectively. We conclude that this PCR-based techniqueis not only absolutely specific, but also very sensitive and therefore muchsuperior to blood culture and, Widal test for the early diagnosis of typhoid.(author)

  1. 14 CFR 27.1413 - Safety belts.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety belts. 27.1413 Section 27.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Safety Equipment § 27.1413 Safety belts. Each safety belt...

  2. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    Science.gov (United States)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  3. Position adopted by the government about the safety options of the EPR reactor project; Prise de position du gouvernement concernant les options de surete du projet de reacteur EPR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-10-01

    On September 28, 2004, on behalf of the French ministers in charge of nuclear safety, the general director of nuclear safety and radiation protection addressed to the president of Electricite de France (EdF) a letter presenting the government's position about the safety options of the EPR (European Pressurized Reactor) project. On the basis of the examination carried out by the nuclear safety authority (ASN) and by the permanent group of reactor experts, the government has considered these options as satisfactory with respect to the safety improvement objectives. Therefore, the government requested EdF to comply with these technical rules for any future reactor development. This dossier includes: the letter of the government, the technical directives for the design and construction of the next generation of PWR-type reactors, the technical rules relative to the design of the main primary and secondary coolant circuits of PWR-type reactors, and the technical file about the safety of the EPR project reprinted from the 2003 report of nuclear safety and radiation protection authority. (J.S.)

  4. 50 CFR 25.71 - Public safety.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Public safety. 25.71 Section 25.71... NATIONAL WILDLIFE REFUGE SYSTEM ADMINISTRATIVE PROVISIONS Safety Regulations § 25.71 Public safety. Persons using national wildlife refuges shall comply with the safety requirements which are established under...

  5. 10 CFR 830.202 - Safety basis.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Safety basis. 830.202 Section 830.202 Energy DEPARTMENT OF ENERGY NUCLEAR SAFETY MANAGEMENT Safety Basis Requirements § 830.202 Safety basis. (a) The contractor responsible for a hazard category 1, 2, or 3 DOE nuclear facility must establish and maintain the safety basis...

  6. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Pluto behaving badly: false beliefs and their consequences.

    Science.gov (United States)

    Berkowitz, Shari R; Laney, Cara; Morris, Erin K; Garry, Maryanne; Loftus, Elizabeth F

    2008-01-01

    We exposed college students to suggestive materials in order to lead them to believe that, as children, they had a negative experience at Disneyland involving the Pluto character. A sizable minority of subjects developed a false belief or memory that Pluto had uncomfortably licked their ear. Suggestions about a positive experience with Pluto led to even greater acceptance of a lovable ear-licking episode. False beliefs and memories had repercussions; those seduced by the bad suggestions were not willing to pay as much for a Pluto souvenir. These findings are among the first to demonstrate that false beliefs can have repercussions for people, meaning that they can influence their later thoughts, beliefs, and behaviors.

  8. 49 CFR 238.103 - Fire safety.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Fire safety. 238.103 Section 238.103..., DEPARTMENT OF TRANSPORTATION PASSENGER EQUIPMENT SAFETY STANDARDS Safety Planning and General Requirements § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a...

  9. Determination of Double Bond Positions in Polyunsaturated Fatty Acids Using the Photochemical Paternò-Büchi Reaction with Acetone and Tandem Mass Spectrometry.

    Science.gov (United States)

    Murphy, Robert C; Okuno, Toshiaki; Johnson, Christopher A; Barkley, Robert M

    2017-08-15

    The positions of double bonds along the carbon chain of methylene interrupted polyunsaturated fatty acids are unique identifiers of specific fatty acids derived from biochemical reactions that occur in cells. It is possible to obtain direct structural information as to these double bond positions using tandem mass spectrometry after collisional activation of the carboxylate anions of an acetone adduct at each of the double bond positions formed by the photochemical Paternò-Büchi reaction with acetone. This reaction can be carried out by exposing a small portion of an inline fused silica capillary to UV photons from a mercury vapor lamp as the sample is infused into the electrospray ion source of a mass spectrometer. Collisional activation of [M - H] - yields a series of reverse Paternò-Büchi reaction product ions that essentially are derived from cleavage of the original carbon-carbon double bonds that yield an isopropenyl carboxylate anion corresponding to each double bond location. Aldehydic reverse Paternò-Büchi product ions are much less abundant as the carbon chain length and number of double bonds increase. The use of a mixture of D 0 /D 6 -acetone facilitates identification of these double bonds indicating product ions as shown for arachidonic acid. If oxygen is present in the solvent stream undergoing UV photoactivation, ozone cleavage ions are also observed without prior collisional activation. This reaction was used to determine the double bond positions in a 20:3 fatty acid that accumulated in phospholipids of RAW 264.7 cells cultured for 3 days.

  10. 20 CFR 638.803 - Safety.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Safety. 638.803 Section 638.803 Employees... THE JOB TRAINING PARTNERSHIP ACT Administrative Provisions § 638.803 Safety. (a) The Job Corps... shall be assigned to such jobs or training in accordance with appropriate health and safety practices...

  11. 49 CFR 385.107 - The safety audit.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false The safety audit. 385.107 Section 385.107 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domicile...

  12. Twenty-First Water Reaction Safety Information Meeting

    International Nuclear Information System (INIS)

    Monteleone, S.

    1994-04-01

    This three-volume report contains 90 papers out of the 102 that were presented at the Twenty-First Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, during the week of October 25--27, 1993. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Germany, Japan, Russia, Switzerland, Taiwan, and United Kingdom. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. Individual papers have been cataloged separately. This document, Volume 2, presents papers on severe accident research

  13. 14 CFR 415.117 - Ground safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Ground safety. 415.117 Section 415.117... TRANSPORTATION LICENSING LAUNCH LICENSE Safety Review and Approval for Launch of an Expendable Launch Vehicle From a Non-Federal Launch Site § 415.117 Ground safety. (a) General. An applicant's safety review...

  14. 14 CFR 415.115 - Flight safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety. 415.115 Section 415.115... TRANSPORTATION LICENSING LAUNCH LICENSE Safety Review and Approval for Launch of an Expendable Launch Vehicle From a Non-Federal Launch Site § 415.115 Flight safety. (a) Flight safety analysis. An applicant's...

  15. Lithium-thionyl chloride cell system safety hazard analysis

    Science.gov (United States)

    Dampier, F. W.

    1985-03-01

    This system safety analysis for the lithium thionyl chloride cell is a critical review of the technical literature pertaining to cell safety and draws conclusions and makes recommendations based on this data. The thermodynamics and kinetics of the electrochemical reactions occurring during discharge are discussed with particular attention given to unstable SOCl2 reduction intermediates. Potentially hazardous reactions between the various cell components and discharge products or impurities that could occur during electrical or thermal abuse are described and the most hazardous conditions and reactions identified. Design factors influencing the safety of Li/SOCl2 cells, shipping and disposal methods and the toxicity of Li/SOCl2 battery components are additional safety issues that are also addressed.

  16. Nuclear Reaction Data Centers

    International Nuclear Information System (INIS)

    McLane, V.; Nordborg, C.; Lemmel, H.D.; Manokhin, V.N.

    1988-01-01

    The cooperating Nuclear Reaction Data Centers are involved in the compilation and exchange of nuclear reaction data for incident neutrons, charged particles and photons. Individual centers may also have services in other areas, e.g., evaluated data, nuclear structure and decay data, reactor physics, nuclear safety; some of this information may also be exchanged between interested centers. 20 refs., 1 tab

  17. Systematic hybrid LOH: a new method to reduce false positives and negatives during screening of yeast gene deletion libraries

    DEFF Research Database (Denmark)

    Alvaro, D.; Sunjevaric, I.; Reid, R. J.

    2006-01-01

    We have developed a new method, systematic hybrid loss of heterozygosity, to facilitate genomic screens utilizing the yeast gene deletion library. Screening is performed using hybrid diploid strains produced through mating the library haploids with strains from a different genetic background......, to minimize the contribution of unpredicted recessive genetic factors present in the individual library strains. We utilize a set of strains where each contains a conditional centromere construct on one of the 16 yeast chromosomes that allows the destabilization and selectable loss of that chromosome. After...... complementation of any spurious recessive mutations in the library strain, facilitating attribution of the observed phenotype to the documented gene deletion and dramatically reducing false positive results commonly obtained in library screens. The systematic hybrid LOH method can be applied to virtually any...

  18. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  19. 21 CFR 610.11 - General safety.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false General safety. 610.11 Section 610.11 Food and... GENERAL BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.11 General safety. A general safety test... for administration to humans. The general safety test is required in addition to other specific tests...

  20. Immune Recovery Syndrome in the HIV-positive patient: Radiological Findings of Paradoxical Reactions

    International Nuclear Information System (INIS)

    Martinez, E.; Sanchez, M. A.; Torres, M.; Benito, J.; Avila, A.

    2004-01-01

    To describe immune recovery syndrome (IRS) and related radiological findings in HIV-positive patients. To alert radiologists to the ever-increasingly frequent appearance of paradoxical reactions (PR) in granulomatous diseases under antiretroviral treatment. We present a retrospective study of 9 adult HIV-positive patients who showed IRS, 6 cases of tuberculosis (TBC), 2 cases of atypical mycobacterium and a case of sarcoidosis. At the time of IRS/PR diagnosis, any suspicion of infectious activity was excluded through the use of appropriate microbiological tests. clinical and radiological characteristics of the above mentioned cases are analyze here. All patients experienced a clinical and/or radiological worsening of condition following variable periods of antiretroviral and/or anti-tuberculosis treatment, and coinciding with viral load decrease and CD4-T-lymphocyte recovery. Diagnosis of IRS/PR was clinical in five cases and radiological in four. In all but one case, antiretroviral treatment had at some time been previously administered. IRS/PR is a diagnosis of exclusion which must be included in the differential diagnosis of newly appearing lesions or worsening of already existing ones in HIV-positive patients that have recently begun antiretroviral and/or anti-tuberculosis treatment. Such should be done after excluding drug resistance, treatment non-adherence and intercurrent disease. (Author) 8 refs

  1. 49 CFR 800.25 - Delegation to the Directors of Office of Aviation Safety, Office of Railroad Safety, Office of...

    Science.gov (United States)

    2010-10-01

    ... Office of Aviation Safety, Office of Railroad Safety, Office of Highway Safety, Office of Marine Safety... Offices of Aviation, Railroad, Highway, Marine, and Pipeline and Hazardous Materials Safety, the authority... 49 Transportation 7 2010-10-01 2010-10-01 false Delegation to the Directors of Office of Aviation...

  2. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  3. Sadder and less accurate? False memory for negative material in depression.

    Science.gov (United States)

    Joormann, Jutta; Teachman, Bethany A; Gotlib, Ian H

    2009-05-01

    Previous research has demonstrated that induced sad mood is associated with increased accuracy of recall in certain memory tasks; the effects of clinical depression, however, are likely to be quite different. The authors used the Deese-Roediger-McDermott paradigm to examine the impact of clinical depression on erroneous recall of neutral and/or emotional stimuli. Specifically, they presented Deese-Roediger-McDermott lists that were highly associated with negative, neutral, or positive lures and compared participants diagnosed with major depressive disorder and nondepressed control participants on the accuracy of their recall of presented material and their false recall of never-presented lures. Compared with control participants, major depressive disorder participants recalled fewer words that had been previously presented but were more likely to falsely recall negative lures; there were no differences between major depressive disorder and control participants in false recall of positive or neutral lures. These findings indicate that depression is associated with false memories of negative material.

  4. Significance of FDG-PET in Identification of Diseases of the Appendix – Based on Experience of Two Cases Falsely Positive for FDG Accumulation

    Directory of Open Access Journals (Sweden)

    Shimpei Ogawa

    2009-04-01

    Full Text Available A discussion of the significance of F-fluorodeoxyglucose positron emission tomography (FDG-PET in the identification of diseases of the appendix is presented based on two cases falsely positive for FDG accumulation. Both cases were palpable for a tumor in the lower right abdominal region and a prominently enlarged appendix was depicted by CT. Although the patients underwent ileocecal resection based on a strong suspicion of appendiceal cancer rather than appendicitis since abnormal accumulation exhibiting maximum standard uptake values (SUVs of 7.27 and 17.11, respectively, was observed at the same site in FDG-PET examination and since there no malignant findings observed histologically, the patients were diagnosed with appendicitis. Although FDG specifically accumulates not only in malignant tumors, but also in diseases such as acute or chronic inflammation, abscesses and lymphadenitis, and identification based on SUVs has been reported to be used as a method of identification, the two cases reported here were both false-positive cases exhibiting high maximum SUVs. At the present time, although the significance of FDG-PET in the identification of diseases of the appendix is somewhat low and there are limitations on its application, various research is currently being conducted with the aim of improving diagnostic accuracy, and it is hoped that additional studies will be conducted in the future.

  5. 40 CFR 243.201 - Safety.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Safety. 243.201 Section 243.201 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE STORAGE... Procedures § 243.201 Safety. ...

  6. 15 CFR 970.205 - Vessel safety.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Vessel safety. 970.205 Section 970.205... safety. In order to provide a basis for the necessary determinations with respect to the safety of life... Safety of Life at Sea, 1974 (SOLAS 74) possesses current valid SOLAS 74 certificates; (2) That any...

  7. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  8. 36 CFR 1004.15 - Safety belts.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Safety belts. 1004.15 Section 1004.15 Parks, Forests, and Public Property PRESIDIO TRUST VEHICLES AND TRAFFIC SAFETY § 1004.15 Safety... administered by the Presidio Trust will have the safety belt or child restraint system properly fastened at all...

  9. Formal Safety versus Real Safety: Quantitative and Qualitative Approaches to Safety Culture – Evidence from Estonia

    Directory of Open Access Journals (Sweden)

    Järvis Marina

    2016-10-01

    Full Text Available This paper examines differences between formal safety and real safety in Estonian small and medium-sized enterprises. The results reveal key issues in safety culture assessment. Statistical analysis of safety culture questionnaires showed many organisations with an outstanding safety culture and positive safety attitudes. However, qualitative data indicated some important safety weaknesses and aspects that should be included in the process of evaluation of safety culture in organisations.

  10. Unexpected heterogeneity of BCR-ABL fusion mRNA detected by polymerase chain reaction in Philadelphia chromosome-positive acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Hooberman, A.L.; Carrino, J.J.; Leibowitz, D.; Rowley, J.D.; Le Beau, M.M.; Arlin, Z.A.; Westbrook, C.A.

    1989-01-01

    The Philadelphia (Ph 1 ) chromosome results in a fusion of portions of the BCR gene from chromosome 22 and the ABL gene from chromosome 9, producing a chimeric BCR-ABL mRNA and protein. In lymphoblastic leukemias, there are two molecular subtypes of the Ph 1 chromosome, one with a rearrangement of the breakpoint cluster region (bcr) of the BCR gene, producing the same 8.5-kilobase BCR-ABL fusion mRNA seen in chronic myelogenous leukemia (CML), and the other, without a bcr rearrangement, producing a 7.0-kilobase BCR-ABL fusion mRNA that is seen only in acute lymphoblastic leukemia (ALL). The authors studied the molecular subtype of the Ph 1 chromosome in 11 cases of Ph 1 -positive ALL, including 2 with a previous diagnosis of CML, using a sensitive method to analyze the mRNA species based on the polymerase chain reaction (PCR). They observed unexpected heterogeneity in BCR-ABL mRNA in this population. They conclude that the PCR gives additional information about the Ph 1 chromosome gene products that cannot be obtained by genomic analysis, but that it cannot be used as the sole means of detection of this chromosomal abnormality in ALL because of the high incidence of false negative results

  11. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    Science.gov (United States)

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  12. 75 FR 72952 - Safety Zone; 1000-yard radius from position 29°48.77′ N 091°33.02′ W, Charenton Drainage and...

    Science.gov (United States)

    2010-11-29

    ...-AA00 Safety Zone; 1000-yard radius from position 29[deg]48.77' N 091[deg]33.02' W, Charenton Drainage.... SUMMARY: The Coast Guard is establishing a temporary safety zone extending to a 1000-yard radius from... Navigation and Drainage Canal will be closed to all marine traffic within a 1000-yard radius of position 29...

  13. 47 CFR 95.1125 - RF safety.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false RF safety. 95.1125 Section 95.1125 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1125 RF safety. Portable devices...

  14. 40 CFR 87.6 - Aircraft safety.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Aircraft safety. 87.6 Section 87.6... POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES General Provisions § 87.6 Aircraft safety. The provisions of... met within the specified time without creating a safety hazard. ...

  15. 33 CFR 159.95 - Safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety. 159.95 Section 159.95... SANITATION DEVICES Design, Construction, and Testing § 159.95 Safety. (a) Each device must— (1) Be free of... explosion or over pressurization as a result of an accumulation of gases; and (3) Meet all other safety...

  16. Framework of nuclear safety and safety assessment

    International Nuclear Information System (INIS)

    Furuta, Kazuo

    2007-01-01

    Since enormous energy is released by nuclear chain reaction mainly as a form of radiation, a great potential risk accompanies utilization of nuclear energy. Safety has been continuously a critical issue therefore from the very beginning of its development. Though the framework of nuclear safety that has been established at an early developmental stage of nuclear engineering is still valid, more comprehensive approaches are required having experienced several events such as Three Mile Island, Chernobyl, and JCO. This article gives a brief view of the most basic principles how nuclear safety is achieved, which were introduced and sophisticated in nuclear engineering but applicable also to other engineering domains in general. (author)

  17. Skin reactions to thimerosal and Leishmania in dogs from a leishmaniasis endemic area: it is better to keep them apart

    Directory of Open Access Journals (Sweden)

    Moacir Paranhos-Silva

    2001-07-01

    Full Text Available Positive Montenegro's skin test is a delayed type hypersensitivity reaction widely used as indicative of previous infection with Leishmania in both humans and dogs. Montenegro's antigen consists of a crude Leishmania antigen solution, usually containing thimerosal as preserving agent. In this work it is shown that a large proportion of dogs (11 out of 56 examined in an endemic area of leishmaniasis presented induration at the site of injection of a diluent containing thimerosal alone. This clearly demonstrates that thimerosal leads to a high number of false positive skin reactions in dogs and that its use in Montenegro's skin test antigenic preparations should be avoided.

  18. False-positive radioactive iodine uptake mimicking miliary lung metastases in a patient affected by papillary thyroid cancer and IgA deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Demidowich, Andrew Paul; Reynolds, James C. [National Institutes of Health, Bethesda (United States); Kundu, Amartya [Dept. of MedicineUniversity of Massachusetts Medical School, Worcester (United States); Celi, Francesco S. [Div. of Endocrinology and MetabolismVirginia Commonwealth UniversityRichmond (United States)

    2016-09-15

    A 42-year-old female with immunoglobulin A deficiency and recurrent sinopulmonary infections underwent thyroidectomy for papillary thyroid cancer (PTC). Follow-up {sup 123}I scintigraphy demonstrated diffuse pulmonary uptake, suggesting metastatic disease. However, subsequent pathologic, biochemical and radiographic testing proved that she was in fact disease free, and the initial {sup 123}I pulmonary uptake was identified as a false positive. Inflammatory conditions may rarely cause iodine uptake in non-thyroidal tissues due to local retention, organification, and/or immunologic utilization. To avoid exposing patients to unnecessary treatments, it is critical for clinicians to recognize that comorbid pulmonary conditions may mimic metastatic PTC on radioiodine scintigraphy.

  19. 46 CFR 197.326 - Oxygen safety.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Oxygen safety. 197.326 Section 197.326 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.326 Oxygen safety. (a) Equipment used with...

  20. 47 CFR 90.1335 - RF safety.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false RF safety. 90.1335 Section 90.1335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Wireless Broadband Services in the 3650-3700 MHz Band § 90.1335 RF safety...

  1. 29 CFR 1926.105 - Safety nets.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Safety nets. 1926.105 Section 1926.105 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life Saving Equipment § 1926.105...

  2. Distance Sensitive Bloom Filters Without False Negatives

    DEFF Research Database (Denmark)

    Goswami, Mayank; Pagh, Rasmus; Silvestri, Francesco

    2017-01-01

    A Bloom filter is a widely used data-structure for representing a set S and answering queries of the form “Is x in S?”. By allowing some false positive answers (saying ‘yes’ when the answer is in fact ‘no’) Bloom filters use space significantly below what is required for storing S. In the distanc...

  3. False-negative diffusion-weighted imaging findings in acute stroke

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Yuasa, Naoki; Otomo, Takashi; Shiramizu, Hideki; Matsuda, Hiroshi; Kitagawa, Yasuhisa; Takagi, Shigeharu

    2006-01-01

    The utility of DWI (diffusion-weighted imaging) has been established in acute ischemic stroke. However, some patients with acute stroke show no abnormal signals on DWI, despite the presence of infarction (false-negative DWI). We analyzed the relationship between false-negative DWI and the clinical manifestations of acute ischemic stroke in 151 DWI-positive (89%) and 19 false-negative DWI (11%) patients. We performed MRI within 24 hours after onset at our hospital. Non-specific clinical manifestations, including vertigo and nausea, were frequently observed in false-negative DWI patients. As regards the vascular territory, false-negative DWI was noted in 15.3% of 59 patients with infarctions within the territory of the vertebrobasilar artery. Concerning the duration from onset to initial imaging, 73.7% of the patients with false-negative DWI findings underwent MRI examination within 6 hours after onset. Of the patients with false-negative DWI, 84.2% had lacunar infarction (χ 2 =16.4, P<0.001). In conclusion, false negative DWI is more frequently observed in lacunar infarction than in atherothrombotic infarction or cardiogenic embolism. It is important to examine carefully the neurological changes occurring in patients who present with acute stroke, but have negative DWI findings. (author)

  4. Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-01

    "9Combustion safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  5. 45 CFR 1310.21 - Safety education.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Safety education. 1310.21 Section 1310.21 Public... PROGRAM HEAD START TRANSPORTATION Special Requirements § 1310.21 Safety education. (a) Each agency must... children. The required transportation and pedestrian safety education of children and parents, except for...

  6. 47 CFR 101.1425 - RF safety.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false RF safety. 101.1425 Section 101.1425 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... safety. MVDDS stations in the 12.2-12.7 GHz frequency band do not operate with output powers that equal...

  7. 14 CFR 31.63 - Safety belts.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety belts. 31.63 Section 31.63 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: MANNED FREE BALLOONS Design Construction § 31.63 Safety belts. (a) There must be a safety belt...

  8. 14 CFR 415.33 - Safety organization.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Safety organization. 415.33 Section 415.33....33 Safety organization. (a) An applicant shall maintain a safety organization and document it by... communication, both within the applicant's organization and between the applicant and any federal launch range...

  9. Benign oral pathology as a cause of false positive 131I uptake in thyroid carcinoma

    International Nuclear Information System (INIS)

    Mansberg, R.; Wadhwa, S.S.; Fernandes, V.B.

    1997-01-01

    Full text: We present three thyroidectomised patients with a history of thyroid carcinoma who had non-metastatic 131 I uptake due to benign oral pathology. A salivary gland study suggested impaired function but no obstruction was demonstrated on a sialogram. The symptoms resolved on antibiotic therapy and a subsequent 131 I study was normal. A subsequent thallium study demonstrated physiological tracer distribution. A 35-year-old female with papillary cell carcinoma of the thyroid demonstrated a focus of uptake on the right hemi-mandible following both a diagnostic and a therapeutic dose of 131 I. This area was tender and an OPG confirmed an area of liquefaction at this site. A 53-year-old female with medullary cell carcinoma of the thyroid demonstrated a focus of uptake in the right side of the maxilla following a diagnostic administration of 131 I. An OPG confirmed an area of liquefaction around the apex of the right upper centre. These three cases illustrate salivary gland and dental inflammation as causes of false positive 131 I uptake. It is important to differentiate non-metastatic 131 I uptake from that due to functioning metastatic thyroid carcinoma in order to avoid inappropriate treatment with large additional doses of 131 I. As in these patients, clinical assessment and the use of anatomical imaging or other isotopes such as thallium or technetium can be helpful in ruling out a mistaken diagnosis of metastasis

  10. False recollection of emotional pictures in Alzheimer's disease.

    Science.gov (United States)

    Gallo, David A; Foster, Katherine T; Wong, Jessica T; Bennett, David A

    2010-10-01

    Alzheimer's Disease (AD) can reduce the effects of emotional content on memory for studied pictures, but less is known about false memory. In healthy adults, emotionally arousing pictures can be more susceptible to false memory effects than neutral pictures, potentially because emotional pictures share conceptual similarities that cause memory confusions. We investigated these effects in AD patients and healthy controls. Participants studied pictures and their verbal labels, and then picture recollection was tested using verbal labels as retrieval cues. Some of the test labels had been associated with a picture at study, whereas other had not. On this picture recollection test, we found that both AD patients and controls incorrectly endorsed some of the test labels that had not been studied with pictures. These errors were associated with medium to high levels of confidence, indicating some degree of false recollection. Critically, these false recollection judgments were greater for emotional compared to neutral items, especially for positively valenced items, in both AD patients and controls. Dysfunction of the amygdala and hippocampus in early AD may impair recollection, but AD did not disrupt the effect of emotion on false recollection judgments. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. 29 CFR 500.100 - Vehicle safety obligations.

    Science.gov (United States)

    2010-07-01

    ... safety standards. Prima facie evidence that safety standards have been met will be shown by the presence... 29 Labor 3 2010-07-01 2010-07-01 false Vehicle safety obligations. 500.100 Section 500.100 Labor... § 500.100 Vehicle safety obligations. (a) General obligations. Each farm labor contractor, agricultural...

  12. 21 CFR 315.6 - Evaluation of safety.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Evaluation of safety. 315.6 Section 315.6 Food and... USE DIAGNOSTIC RADIOPHARMACEUTICALS § 315.6 Evaluation of safety. (a) Factors considered in the safety...)(1) To establish the safety of a diagnostic radiopharmaceutical, FDA may require, among other...

  13. False memory and the associative network of happiness.

    Science.gov (United States)

    Koo, Minkyung; Oishi, Shigehiro

    2009-02-01

    This research examines the relationship between individuals' levels of life satisfaction and their associative networks of happiness. Study 1 measured European Americans' degree of false memory of happiness using the Deese-Roediger-McDermott paradigm. Scores on the Satisfaction With Life Scale predicted the likelihood of false memory of happiness but not of other lure words such as sleep . In Study 2, European American participants completed an association-judgment task in which they judged the extent to which happiness and each of 15 positive emotion terms were associated with each other. Consistent with Study 1's findings, chronically satisfied individuals exhibited stronger associations between happiness and other positive emotion terms than did unsatisfied individuals. However, Koreans and Asian Americans did not exhibit such a pattern regarding their chronic level of life satisfaction (Study 3). In combination, results suggest that there are important individual and cultural differences in the cognitive structure and associative network of happiness.

  14. Modeling Kepler Transit Light Curves as False Positives: Rejection of Blend Scenarios for Kepler-9, and Validation of Kepler-9 d, a Super-Earth-Size Planet in a Multiple System

    Science.gov (United States)

    Torres, Guillermo; Fressin, Francois; Batalha, Natalie M.; Borucki, William J.; Brown, Timothy M.; Bryson, Stephen T.; Buchhave, Lars A.; Charbonneau, David; Ciardi, David R.; Dunham, Edward W.; hide

    2011-01-01

    Light curves from the Kepler Mission contain valuable information on the nature of the phenomena producing the transit-like signals. To assist in exploring the possibility that they are due to an astrophysical false positive we describe a procedure (BLENDER) to model the photometry in terms of a blend rather than a planet orbiting a star. A blend may consist of a background or foreground eclipsing binary (or star-planet pair) whose eclipses are attenuated by the light of the candidate and possibly other stars within the photometric aperture. We apply BLENDER to the case of Kepler-9 (KIC 3323887), a target harboring two previously confirmed Saturn-size planets (Kepler-9 b and Kepler-9 c) showing transit timing variations, and an additional shallower signal with a 1.59 day period suggesting the presence of a super-Earth-size planet. Using BLENDER together with constraints from other follow-up observations we are able to rule out all blends for the two deeper signals and provide independent validation of their planetary nature. For the shallower signal, we rule out a large fraction of the false positives that might mimic the transits. The false alarm rate for remaining blends depends in part (and inversely) on the unknown frequency of small-size planets. Based on several realistic estimates of this frequency, we conclude with very high confidence that this small signal is due to a super-Earth-size planet (Kepler-9 d) in a multiple system, rather than a false positive. The radius is determined to be 1.64(exp)(sub-14),R, and current spectroscopic observations are as yet insufficient to establish its mass.

  15. 40 CFR 240.209 - Safety.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Safety. 240.209 Section 240.209 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.209 Safety. ...

  16. Investigation of Na-CO2 Reaction with Initial Reaction in Various Reacting Surface

    International Nuclear Information System (INIS)

    Kim, Hyun Su; Park, Gunyeop; Kim, Soo Jae; Park, Hyun Sun; Kim, Moo Hwan; Wi, Myung-Hwan

    2015-01-01

    The reaction products that cause oxidation and erosion are threaten the heat transfer tubes so that it is necessary to investigate Na-CO 2 reaction according to various experimental parameter. Unlike SWR, Na-CO 2 reaction is more complex to deal with reaction kinetics. Since a comprehensive understanding of Na-CO 2 reaction mechanism is crucial for the safety analysis, the reaction phenomenon under the various conditions was investigated. The current issue is to make a database for developing computational code for CO 2 gas leak situation because it is experimentally difficult to analyze the actual accident situation. Most studies on Na-CO 2 interaction reports that chemical reaction is getting vigorous as temperature increased and reactivity is sensitive as temperature change between 400 .deg. C and 600 .deg. C. Therefore, temperature range is determined based on the operating condition (450 - 500 .deg. C) of KALIMER-600 employed as supercritical CO 2 brayton cycle energy conversion system for Na-CO 2 heat exchanger. And next parameter is sodium surface area which contact between sodium and CO 2 when CO 2 is injected into sodium pool in the accident situation. So, the fundamental surface reaction is experimentally studied in the range of 8 - 12cm 2 . Additionally, it has been reported in recent years that CO 2 Flow rate affects reactivity less significantly and CO 2 flow rate is assumed that 5 SLPM (standard liter per minute) is suitable as a basis for a small leakage. The finally selected control parameters is sodium temperature and reacting surface area with constant CO 2 flow rate. Na-CO 2 reaction test is performed for investigating risk of potential accident which contacts with liquid sodium and CO 2 . Amount of reaction is saturated as time passed because of kept a balance between production of solid phase reaction products and amount of diffusivity. These results contribute to make a database for the SFR safety analysis and additional experiments are needed

  17. A field ion microscope study of the surface reaction of tungsten with n-octanol under an applied positive voltage: reaction conditions for the 'splitting' of (110) plane

    International Nuclear Information System (INIS)

    Terao, T.; Iwatsu, F.; Morikawa, H.

    1993-01-01

    Field ion microscopy is a powerful tool for the study of surface phenomena on an atomic scale, especially when they are crystal plane dependent, because the microscope shows many crystal planes of the sample tip simultaneously. Although a large number of FIM studies on vapor deposition, surface diffusion and surface reactions at a metal-gas interface have been reported, those on reactions at a metal-liquid interface are few. The authors have studied the corrosion or tungsten with aqueous solutions and found that water corroded the tungsten tips very severely to reduce the radius of curvature of the tip cap drastically. The reaction was so severe that it was not possible to trace it back to the very initial stages. They adopted, as a weaker reagent, one of the higher alcohols, n-octanol(C 8 H 17 OH), and found that it reacted with tungsten tips when an electrical pulse with a positive voltage between 5 and 10V was applied to the tip, giving very interesting field ion images in which the central (110) plane was divided into two parts located side by side across the [001] zone line. This means that some anisotropic surface reaction occurred which made a groove along the [001] zone line going through the (110) plane, usually the most stable plane chemically for bcc metals. They named this phenomenon 'splitting'. This reaction was less severe than that with water and some results on the morphology of the groove and on the reaction sequence have been reported. In the present paper more detailed reaction conditions which give rise to the splitting are described

  18. Safety Climate, Perceived Risk, and Involvement in Safety Management

    OpenAIRE

    Kouabenan , Dongo Rémi; Ngueutsa , Robert ,; Safiétou , Mbaye

    2015-01-01

    International audience; This article examines the relationship between safety climate, risk perception and involvement in safety management by first-line managers (FLM). Sixty-three FLMs from two French nuclear plants answered a questionnaire measuring perceived workplace safety climate, perceived risk, and involvement in safety management. We hypothesized that a positive perception of safety climate would promote substantial involvement in safety management, and that this effect would be str...

  19. Reaction Qualifications Revisited

    DEFF Research Database (Denmark)

    Lippert-Rasmussen, Kasper

    2009-01-01

    to a person's effectiveness by causing a favourable reaction in customers, co-workers etc. (for short: recipients) - are involved, this assumption is false. Building on work by Wertheimer, Mason, and Miller, this paper proposes an account of the reaction qualifications that count, from the point of view...... preferences, recipients should not respond to the applicant actually hired on the basis of their (the recipients') racial preferences. My account decomposes the meritocratic ideal into four separate norms, one of which applies to recipients rather than to selectors. Finally, it defends the view that reaction...... qualifications based on antimeritocratic reactions, while not unproblematic, are not entirely irrelevant from the point of view of merit. Notably, selectors need not discount them when no one - including the targets of the objectionable preferences - is unfairly disadvantaged. Because not all problematic...

  20. 47 CFR 101.1525 - RF safety.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false RF safety. 101.1525 Section 101.1525 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Service and Technical Rules for the 70/80/90 GHz Bands § 101.1525 RF safety. Licensees in the 70...

  1. 46 CFR 169.723 - Safety belts.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Safety belts. 169.723 Section 169.723 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.723 Safety belts. Each vessel must carry a harness type safety belt conforming to Offshore Racing Council (ORC) standards for each person on watch or...

  2. 14 CFR 431.33 - Safety organization.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Safety organization. 431.33 Section 431.33... Launch and Reentry of a Reusable Launch Vehicle § 431.33 Safety organization. (a) An applicant shall maintain a safety organization and document it by identifying lines of communication and approval authority...

  3. Safety and tolerability of repetitive transcranial magnetic stimulation in patients with pathologic positive sensory phenomena: a review of literature

    Science.gov (United States)

    Muller, Paul A; Pascual-Leone, Alvaro; Rotenberg, Alexander

    2013-01-01

    BACKGROUND Repetitive transcranial magnetic stimulation (rTMS) is emerging as a valuable therapeutic and diagnostic tool. rTMS appears particularly promising for disorders characterized by positive sensory phenomena attributable to alterations in sensory cortex excitability. Among these are tinnitus, auditory and visual hallucinations, and pain syndromes. OBJECTIVE Despite studies addressing rTMS efficacy in suppression of positive sensory symptoms, the safety of stimulation of potentially hyperexcitable cortex has not been fully addressed. We performed a systematic literature review and metanalysis to describe the rTMS safety profile in these disorders. METHODS Using the PubMed database, we performed an English-language literature search from January 1985 to April 2011 to review all pertinent publications. Per study, we noted and listed pertinent details. From these data we also calculated a crude per-subject risk for each adverse event. RESULTS 106 publications (n = 1815 subjects) were identified with patients undergoing rTMS for pathologic positive sensory phenomena. Adverse events associated with rTMS were generally mild and occurred in 16.7% of subjects. Seizure was the most serious adverse event, and occurred in three patients with a 0.16% crude per-subject risk. The second most severe adverse event involved aggravation of sensory phenomena, occurring in 1.54%. CONCLUSIONS The published data suggest rTMS for the treatment or diagnosis of pathologic positive sensory phenomena appears to be a relatively safe and well-tolerated procedure. However, published data are lacking in systematic reporting of adverse events, and safety risks of rTMS in these patient populations will have to be addressed in future prospective trials. PMID:22322098

  4. Too Good to be False: Nonsignificant Results Revisited

    Directory of Open Access Journals (Sweden)

    Chris H. J. Hartgerink

    2017-03-01

    Full Text Available Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant findings may just be ‘too good to be false’. We examined evidence for false negatives in nonsignificant results in three different ways. We adapted the Fisher test to detect the presence of at least one false negative in a set of statistically nonsignificant results. Simulations show that the adapted Fisher method generally is a powerful method to detect false negatives. We examined evidence for false negatives in the psychology literature in three applications of the adapted Fisher method. These applications indicate that (i the observed effect size distribution of nonsignificant effects exceeds the expected distribution assuming a null-effect, and approximately two out of three (66.7% psychology articles reporting nonsignificant results contain evidence for at least one false negative, (ii nonsignificant results on gender effects contain evidence of true nonzero effects, and (iii the statistically nonsignificant replications from the Reproducibility Project Psychology (RPP do not warrant strong conclusions about the absence or presence of true zero effects underlying these nonsignificant results. We conclude that false negatives deserve more attention in the current debate on statistical practices in psychology. Potentially neglecting effects due to a lack of statistical power can lead to a waste of research resources and stifle the scientific discovery process.

  5. Results of neutron measurements in the spectral position of the Juelich FKS steel irradiation capsules

    International Nuclear Information System (INIS)

    Schneider, W.

    1986-10-01

    This is a report on the planning and results of neutron monitoring in the capsules of the Juelich steel irradiation for the research project on component safety (FKS). The table of results and their discussion is provided specifically for the spectral positions (for characterising the neutron spectrum) in each of the types of irradiation capsules used. The results are given for the reaction rates of the neutron measurement reactions used (activation or fission reactions), for the neutron flux densities and fluxes derived from them related to the actual or at least plausible neutron spectra and finally for the radiation damage (or exposure) of the irradiated material calculated from them, expressed as the atomic displacement figure (dpa) and its percentage in sections of the neutron spectrum. (orig.) [de

  6. False memories and memory confidence in borderline patients.

    Science.gov (United States)

    Schilling, Lisa; Wingenfeld, Katja; Spitzer, Carsten; Nagel, Matthias; Moritz, Steffen

    2013-12-01

    Mixed results have been obtained regarding memory in patients with borderline personality disorder (BPD). Prior reports and anecdotal evidence suggests that patients with BPD are prone to false memories but this assumption has to been put to firm empirical test, yet. Memory accuracy and confidence was assessed in 20 BPD patients and 22 healthy controls using a visual variant of the false memory (Deese-Roediger-McDermott) paradigm which involved a negative and a positive-valenced picture. Groups did not differ regarding veridical item recognition. Importantly, patients did not display more false memories than controls. At trend level, borderline patients rated more items as new with high confidence compared to healthy controls. The results tentatively suggest that borderline patients show uncompromised visual memory functions and display no increased susceptibility for distorted memories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Sample Size Calculation for Controlling False Discovery Proportion

    Directory of Open Access Journals (Sweden)

    Shulian Shang

    2012-01-01

    Full Text Available The false discovery proportion (FDP, the proportion of incorrect rejections among all rejections, is a direct measure of abundance of false positive findings in multiple testing. Many methods have been proposed to control FDP, but they are too conservative to be useful for power analysis. Study designs for controlling the mean of FDP, which is false discovery rate, have been commonly used. However, there has been little attempt to design study with direct FDP control to achieve certain level of efficiency. We provide a sample size calculation method using the variance formula of the FDP under weak-dependence assumptions to achieve the desired overall power. The relationship between design parameters and sample size is explored. The adequacy of the procedure is assessed by simulation. We illustrate the method using estimated correlations from a prostate cancer dataset.

  8. Systematic drug safety evaluation based on public genomic expression (Connectivity Map) data: myocardial and infectious adverse reactions as application cases.

    Science.gov (United States)

    Wang, Kejian; Weng, Zuquan; Sun, Liya; Sun, Jiazhi; Zhou, Shu-Feng; He, Lin

    2015-02-13

    Adverse drug reaction (ADR) is of great importance to both regulatory agencies and the pharmaceutical industry. Various techniques, such as quantitative structure-activity relationship (QSAR) and animal toxicology, are widely used to identify potential risks during the preclinical stage of drug development. Despite these efforts, drugs with safety liabilities can still pass through safety checkpoints and enter the market. This situation raises the concern that conventional chemical structure analysis and phenotypic screening are not sufficient to avoid all clinical adverse events. Genomic expression data following in vitro drug treatments characterize drug actions and thus have become widely used in drug repositioning. In the present study, we explored prediction of ADRs based on the drug-induced gene-expression profiles from cultured human cells in the Connectivity Map (CMap) database. The results showed that drugs inducing comparable ADRs generally lead to similar CMap expression profiles. Based on such ADR-gene expression association, we established prediction models for various ADRs, including severe myocardial and infectious events. Drugs with FDA boxed warnings of safety liability were effectively identified. We therefore suggest that drug-induced gene expression change, in combination with effective computational methods, may provide a new dimension of information to facilitate systematic drug safety evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. 14 CFR 34.6 - Aircraft safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Aircraft safety. 34.6 Section 34.6... safety. (a) The provisions of this part will be revised if at any time the Administrator determines that an emission standard cannot be met within the specified time without creating a safety hazard. (b...

  10. 7 CFR 1724.55 - Dam safety.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Dam safety. 1724.55 Section 1724.55 Agriculture... § 1724.55 Dam safety. (a) The provisions of this section apply only to RUS financed electric system... for Dam Safety,”(Guidelines), as applicable. A dam, as more fully defined in the Guidelines, is...

  11. 31 CFR 560.528 - Aircraft safety.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Aircraft safety. 560.528 Section 560..., Authorizations and Statements of Licensing Policy § 560.528 Aircraft safety. Specific licenses may be issued on a... the safety of civil aviation and safe operation of U.S.-origin commercial passenger aircraft. ...

  12. Expectations of the Swiss safety authorities

    International Nuclear Information System (INIS)

    Naegelin, R.

    1994-01-01

    On the one hand, nuclear energy can contribute significantly to our energy supply without much environmental consequences. On the other hand, there is a potential for large environmental consequences. The nuclear power plants are vastly different from conventional industrial activities where much has been learned through trial and error processes leading to slow improvements in their safety performance. Hence one cannot afford to learn from mistakes as an approach to safety improvement. It is more important to think ahead and precautions must be taken through proper design and operation before accidents can occur. The precondition for such an approach is what one now refers to as 'safety culture'. This requires a prerequisite frame of mind to 'desire' safety. In addition, the necessary technical 'ability' is also required, without which any culture cannot be realized. Culture is a human reaction to its environment so that it can live in harmony with the real or imaginary world. In the course of human history, different cultures, e.g. hunters and farmers, have evolved to adopt with the prevailing habitats. The term culture is also associated with a humane form of pre-industrial and industrial society. These cultures were, at least partially, the result of pressure to perform suitable actions. However, in the present modern times, things function quite well with less apparent pressure. Thereby positive values in the working culture become questionable. The traits that are endangered include thoroughness, carefulness and sense of duty in ones daily work habits. Also the removal of work from its central position in human life is involved, threatening care by pressure or time and costs. (author)

  13. 40 CFR 68.65 - Process safety information.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.65 Process safety... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Process safety information. 68.65... compilation of written process safety information before conducting any process hazard analysis required by...

  14. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  15. Growth Hormone Safety Workshop Position Paper: a critical appraisal of recombinant human growth hormone therapy in children and adults

    DEFF Research Database (Denmark)

    Allen, David B; Backeljauw, Philippe; Bidlingmaier, Martin

    2015-01-01

    Recombinant human GH (rhGH) has been in use for 30 years, and over that time its safety and efficacy in children and adults has been subject to considerable scrutiny. In 2001, a statement from the GH Research Society (GRS) concluded that 'for approved indications, GH is safe'; however, the statem...... (PES) convened a meeting to reappraise the safety of rhGH. The ouput of the meeting is a concise position statement.......Recombinant human GH (rhGH) has been in use for 30 years, and over that time its safety and efficacy in children and adults has been subject to considerable scrutiny. In 2001, a statement from the GH Research Society (GRS) concluded that 'for approved indications, GH is safe'; however......, the statement highlighted a number of areas for on-going surveillance of long-term safety, including cancer risk, impact on glucose homeostasis, and use of high dose pharmacological rhGH treatment. Over the intervening years, there have been a number of publications addressing the safety of rhGH with regard...

  16. Confabulation versus experimentally induced false memories in Korsakoff patients.

    Science.gov (United States)

    Van Damme, Ilse; d'Ydewalle, Géry

    2010-09-01

    The present study focuses on both the clinical symptom of confabulation and experimentally induced false memories in patients suffering from Korsakoff's syndrome. Despite the vast amount of case studies of confabulating patients and studies investigating false memories in the Deese-Roediger-McDermott (DRM) paradigm, the nature of Korsakoff patients' confabulatory behaviour and its association with DRM false memories have been rarely examined. Hence, the first aim of the present study was to evaluate confabulatory responses in a large sample of chronic Korsakoff patients and matched controls by means of the Dalla Barba Confabulation Battery. Second, the association between (provoked) confabulation and the patients' DRM false recognition performance was investigated. Korsakoff patients mainly confabulated in response to questions about episodic memory and questions to which the answer was unknown. A positive association was obtained between confabulation and the tendency to accept unstudied distractor words as being old in the DRM paradigm. On the other hand, there was a negative association between confabulation and false recognition of critical lures. The latter could be attributed to the importance of strategic retrieval at delayed memory testing.

  17. 40 CFR 257.3-8 - Safety.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Safety. 257.3-8 Section 257.3-8... and Practices § 257.3-8 Safety. (a) Explosive gases. The concentration of explosive gases generated by... shall not pose a hazard to the safety of persons or property from fires. This may be accomplished...

  18. Chemical reactions induced and probed by positive muons

    International Nuclear Information System (INIS)

    Ito, Yasuo

    1990-01-01

    The application of μ + science, collectively called μSR, but encompassing a variety of methods including muon spin rotation, muon spin relaxation, muon spin repolarization, muon spin resonance and level-crossing resonance, to chemistry is introduced emphasizing the special aspects of processes which are 'induced and probed' by the μ + itself. After giving a general introduction to the nature and methods of muon science and a short history of muon chemistry, selected topics are given. One concerns the usefulness of muonium as hydrogen-like probes of chemical reactions taking polymerization of vinyl monomers and reaction with thiosulphate as examples. Probing solitons in polyacetylene induced and probed by μ + is also an important example which shows the unique nature of muonium. Another important topic is 'lost polarization'. Although this term is particular to muonium. Another important topic is 'lost polarization'. Although this term is particular to muon chemistry, the chemistry underlining the phenomenon of lost polarization has an importance to both radiation and hot atom chemistries. (orig.)

  19. Desensitization in delayed drug hypersensitivity reactions -- an EAACI position paper of the Drug Allergy Interest Group.

    Science.gov (United States)

    Scherer, K; Brockow, K; Aberer, W; Gooi, J H C; Demoly, P; Romano, A; Schnyder, B; Whitaker, P; Cernadas, J S R; Bircher, A J

    2013-07-01

    Drug hypersensitivity may deprive patients of drug therapy, and occasionally no effective alternative treatment is available. Successful desensitization has been well documented in delayed drug hypersensitivity reactions. In certain situations, such as sulfonamide hypersensitivity in HIV-positive patients or hypersensitivity to antibiotics in patients with cystic fibrosis, published success rates reach 80%, and this procedure appears helpful for the patient management. A state of clinical tolerance may be achieved by the administration of increasing doses of the previously offending drug. However, in most cases, a pre-existent sensitization has not been proven by positive skin tests. Successful re-administration may have occurred in nonsensitized patients. A better understanding of the underlying mechanisms of desensitization is needed. Currently, desensitization in delayed hypersensitivity reactions is restricted to mild, uncomplicated exanthems and fixed drug eruptions. The published success rates vary depending on clinical manifestations, drugs, and applied protocols. Slower protocols tend to be more effective than rush protocols; however, underreporting of unsuccessful procedures is very probable. The decision to desensitize a patient must always be made on an individual basis, balancing risks and benefits. This paper reviews the literature and presents the expert experience of the Drug Hypersensitivity Interest Group of the European Academy of Allergy and Clinical Immunology. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. A critical reappraisal of false negative sentinel lymph node biopsy in melanoma

    International Nuclear Information System (INIS)

    Manca, G.; Mazzarri, S.; Boni, G.; Chiacchio, S.; Tredici, M.; Duce, V.; Tardelli, E.; Volterrani, D.; Mariani, G.; Romanini, A.; Rubello, D.

    2014-01-01

    Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of “actual” positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the

  1. 9 CFR 113.39 - Cat safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cat safety tests. 113.39 Section 113... Procedures § 113.39 Cat safety tests. The safety tests provided in this section shall be conducted when... recommended for use in cats. (a) The cat safety test provided in this paragraph shall be used when the Master...

  2. Emotion and false memory: How goal-irrelevance can be relevant for what people remember.

    Science.gov (United States)

    Van Damme, Ilse; Kaplan, Robin L; Levine, Linda J; Loftus, Elizabeth F

    2017-02-01

    Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment or failure has already occurred (e.g., happiness and devastation). Participants watched a slideshow depicting an interaction between a couple and were asked to empathise with the protagonist's feelings of hope (positive pregoal), happiness (positive postgoal), fear (negative pregoal), or devastation (negative postgoal); in control conditions, no emotion was mentioned. Participants were then asked to reflect on details of the interaction that had occurred (true) or had not occurred (false), and that were relevant or irrelevant to the protagonist's goal. Irrespective of emotional valence, participants in the pregoal conditions were more susceptible to false memories concerning goal-irrelevant details than were participants in the other conditions. These findings support the view that pregoal emotions narrow attention to information relevant to goal pursuit, increasing susceptibility to false memories for irrelevant information.

  3. Feature-guided analysis for reduction of false positives in CAD of polyps for computed tomographic colonography

    International Nuclear Information System (INIS)

    Naeppi, Janne; Yoshida, Hiroyuki

    2003-01-01

    We evaluated the effect of our novel technique of feature-guided analysis of polyps on the reduction of false-positive (FP) findings generated by our computer-aided diagnosis (CAD) scheme for the detection of polyps from computed tomography colonographic data sets. The detection performance obtained by use of feature-guided analysis in the segmentation and feature analysis of polyp candidates was compared with that obtained by use of our previously employed fuzzy clustering technique. We also evaluated the effect of a feature called modified gradient concentration (MGC) on the detection performance. A total of 144 data sets, representing prone and supine views of 72 patients that included 14 patients with 21 colorectal polyps 5-25 mm in diameter, were used in the evaluation. At a 100% by-patient (95% by-polyp) detection sensitivity, the FP rate of our CAD scheme with feature-guided analysis based on round-robin evaluation was 1.3 (1.5) FP detections per patient. This corresponds to a 70-75 % reduction in the number of FPs obtained by use of fuzzy clustering at the same sensitivity levels. Application of the MGC feature instead of our previously used gradient concentration feature did not improve the detection result. The results indicate that feature-guided analysis is useful for achieving high sensitivity and a low FP rate in our CAD scheme

  4. Testosterone Replacement Therapy: Long-Term Safety and Efficacy

    Directory of Open Access Journals (Sweden)

    Giovanni Corona

    2017-08-01

    Full Text Available Recent position statements and guidelines have raised the distinction between a true and false, age-related hypogonadism (HG or late-onset hypogonadism (LOH. The former is the consequence of congenital or acquired “organic” damage of the brain centers or of the testis. The latter is mainly secondary to age-related comorbidities and does not require testosterone (T therapy (TTh. In addition, concerns related to cardiovascular (CV safety have further increased the scepticism related to TTh. In this paper, we reviewed the available evidence supporting the efficacy of TTh in non-organic HG and its long term safety. A large amount of evidence has documented that sexual symptoms are the most specific correlates of T deficiency. TTh is able to improve all aspects of sexual function independent of the pathogenetic origin of the disease supporting the scientific demonstration that LOH does exist according to an “ex-juvantibus” criterion. Although the presence of metabolic derangements could mitigate the efficacy of TTh on erectile dysfunction, the positive effect of TTh on body composition and insulin sensitivity might counterbalance the lower efficacy. CV safety concerns related to TTh are essentially based on a limited number of observational and randomized controlled trials which present important methodological flaws. When HG is properly diagnosed and TTh correctly performed no CV and prostate risk have been documented.

  5. Safety in construction?

    NARCIS (Netherlands)

    Swuste, P.H.J.J.

    2013-01-01

    The available literature on Construction Safety is not very optimistic about the chances of evidence-based safety in the construction industry exerting a positive influence. Many articles indicate that the structures and processes that are designed to ensure safety in the industry are poor. Safety

  6. Heat treatment and false-positive heartworm antigen testing in ex vivo parasites and dogs naturally infected by Dirofilaria repens and Angiostrongylus vasorum

    Directory of Open Access Journals (Sweden)

    Luigi Venco

    2017-11-01

    Full Text Available Abstract Background Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen–antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min. Results Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites’ antigens that are normally not released into the bloodstream or released in a low amount and/or bound to

  7. Investigating Initial Disclosures and Reactions to Unexpected, Positive HPV Diagnosis.

    Science.gov (United States)

    Smith, Rachel A; Hernandez, Rachael; Catona, Danielle

    2014-07-01

    Initial disclosures of health conditions are critical communication moments. Existing research focuses on disclosers; integrating confidants into studies of initial disclosures is needed. Guided by the disclosure decision-making model (DD-MM; Greene, 2009), this study examined what diagnosed persons and confidants may say when faced with unexpected test results and unexpected disclosures, respectively. Participants ( N = 151) recorded an audio-visual message for another person, after imagining that they or the other person had just received unexpected, positive HPV test results. The qualitative analysis revealed four themes: (1) impression management and social distance, (2) invisible symptoms and advice regarding future disclosures, (3) expressing and acknowledging emotional reactions, and (4) misunderstandings and lacking knowledge about HPV. These findings suggested that DD-MM may be a relevant framework for understanding not only when disclosers share, but what disclosers and confidants say in early conversations about new diagnoses. While disclosers' and confidants' messages showed marked similarities, important differences appeared. For example, confidants focused on assuaging disclosers' fear about the consequences, whereas disclosers expressed distress related to their uncertainty about the prognosis of an HPV infection and how to prepare for next steps. The discussion highlighted implications for the DD-MM, HPV disclosures, and future interventions.

  8. 49 CFR 659.27 - Internal safety and security reviews.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Internal safety and security reviews. 659.27... State Oversight Agency § 659.27 Internal safety and security reviews. (a) The oversight agency shall... safety and security reviews in its system safety program plan. (b) The internal safety and security...

  9. 14 CFR 23.303 - Factor of safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Factor of safety. 23.303 Section 23.303... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure General § 23.303 Factor of safety. Unless otherwise provided, a factor of safety of 1.5 must be used. ...

  10. 28 CFR 345.83 - Job safety training.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Job safety training. 345.83 Section 345... INDUSTRIES (FPI) INMATE WORK PROGRAMS FPI Inmate Training and Scholarship Programs § 345.83 Job safety training. FPI provides inmates with regular job safety training which is developed and scheduled in...

  11. 14 CFR 31.25 - Factor of safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Factor of safety. 31.25 Section 31.25... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.25 Factor of safety. (a) Except as specified in paragraphs (b) and (c) of this section, the factor of safety is 1.5. (b) A factor of safety of at least five...

  12. Enhancing the Statistical Filtering Scheme to Detect False Negative Attacks in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2017-06-01

    Full Text Available In this paper, we present a technique that detects both false positive and false negative attacks in statistical filtering-based wireless sensor networks. In statistical filtering scheme, legitimate reports are repeatedly verified en route before they reach the base station, which causes heavy energy consumption. While the original statistical filtering scheme detects only false reports, our proposed method promises to detect both attacks.

  13. Development and application of nuclear safety goals in Japan. Lessons learnt from the case of 2003 draft safety goals

    International Nuclear Information System (INIS)

    Sugawara, Shin-etsu; Inamura, Tomoaki

    2016-01-01

    The Nuclear Safety Commission in Japan offered a detailed draft of nuclear safety goals to the public in 2003, though its position was ambiguous in nuclear safety regulation. This report shows the circumstances behind the development and application of 2003 draft safety goals based on our interviews with the experts who had been involved in making the draft. According to our interviews, they had intention to utilize safety goals for improving risk management of regulatory authority and nuclear energy industry, such as ameliorating deterministic regulations, accumulating experience of risk assessment and management, promoting related research, and communicating risks with general public. In practice, however, safety goals had functioned as a tool for emphasizing an assertion that 'nuclear power plants had already been safe enough'. We identified the following four major impediments to utilizing safety goals; 1) lack of sharing overall recognition of the importance of establishing safety goals among nuclear community, 2) excessive emphasis of internal event risks which leads to an inferior priority to tackle with the issue of external events risks, 3) adverse effect of 'tunnel-visioned incrementalism', that is, nuclear energy industrial entities are attracted their foci too much on what they have been told to do by regulators or local governments, and, 4) negative attitude to disclose the outcomes of risk assessment for fear of societal reactions. To encourage upcoming safety goals and risk management, this report provides the following points for overcoming these problems; 1) sharing insights on the reasons why nuclear community set up safety goals, 2) introducing the concept of adaptive risk management for maintaining questioning attitude, 3) conducting a periodic review of goal attainment level and also safety goals themselves from the eyes of a detached observer, and, 4) rebuilding relationship with society beginning with arguments with local stakeholders over

  14. 49 CFR 211.61 - Informal safety inquiries.

    Science.gov (United States)

    2010-10-01

    ... information on selected topics relating to railroad safety. A notice of each such inquiry will be published in... 49 Transportation 4 2010-10-01 2010-10-01 false Informal safety inquiries. 211.61 Section 211.61..., DEPARTMENT OF TRANSPORTATION RULES OF PRACTICE Miscellaneous Safety-Related Proceedings and Inquiries § 211...

  15. 46 CFR 62.35-10 - Flooding safety.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Flooding safety. 62.35-10 Section 62.35-10 Shipping... Requirements for Specific Types of Automated Vital Systems § 62.35-10 Flooding safety. (a) Automatic bilge.... (b) Remote controls for flooding safety equipment must remain functional under flooding conditions to...

  16. 30 CFR 56.4402 - Safety can use.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Safety can use. 56.4402 Section 56.4402 Mineral... and Combustible Liquids and Gases § 56.4402 Safety can use. Small quantities of flammable liquids drawn from storage shall be kept in safety cans labeled to indicate the contents. ...

  17. 30 CFR 57.4402 - Safety can use.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Safety can use. 57.4402 Section 57.4402 Mineral... Flammable and Combustible Liquids and Gases § 57.4402 Safety can use. Small quantities of flammable liquids drawn from storage shall be kept in safety cans labeled to indicate the contents. ...

  18. 20 CFR 401.160 - Health or safety.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Health or safety. 401.160 Section 401.160... INFORMATION Disclosure of Official Records and Information § 401.160 Health or safety. The Privacy Act allows us to disclose information in compelling circumstances where an individual's health or safety is...

  19. 45 CFR 1321.75 - Licenses and safety.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Licenses and safety. 1321.75 Section 1321.75... AND COMMUNITY PROGRAMS ON AGING Service Requirements § 1321.75 Licenses and safety. The State shall... that the facility complies with all applicable State and local health, fire, safety, building, zoning...

  20. 47 CFR 27.52 - RF safety.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false RF safety. 27.52 Section 27.52 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES Technical Standards § 27.52 RF safety. Licensees and manufacturers are subject to the...

  1. 47 CFR 80.1135 - Transmission of maritime safety information.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmission of maritime safety information. 80... RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1135 Transmission of maritime safety...

  2. 76 FR 4532 - Safety Zone; 500 Yards North and South, Bank to Bank, of Position 29°48.77′ N 091°33.02′ W...

    Science.gov (United States)

    2011-01-26

    ...-AA00 Safety Zone; 500 Yards North and South, Bank to Bank, of Position 29[deg]48.77' N 091[deg]33.02' W... and South, bank to bank, of position 29[deg]48.77' N 091[deg]33.02' W, Charenton Drainage and Navigation Canal, St. Mary Parish, LA. This Safety Zone is needed to protect the general public, vessels and...

  3. WWER safety analysis in case of simultaneous positive reactivity introduction by control rods withdrawal and pure condensate injection

    International Nuclear Information System (INIS)

    Kuchin, A.; Ovdiienko, I.; Khalimonchuk, V.

    2011-01-01

    Results of calculation assessment of positive reactivity insertion rate are presented under condition of simultaneous effect on reactivity of two provided by WWER project reactivity operation systems - extract of regulation group and decrease of boron acid concentration. Showed that maximal positive reactivity insertion rate is achieved at hot zero power and it's too less than limit value 0.07β eff /sec defined by normative document 'Nuclear safety regulation of NPP with pressurized water reactors'. For given reasons concluded that necessity of application of the extended protection PZ-2 actuation time is absent on interval of pure condensate transportation for full exclusion of possibility of positive reactivity insertion simultaneously by two different operation systems. (Authors)

  4. Veridical and false recall in adults who stutter.

    Science.gov (United States)

    Byrd, Courtney T; Sheng, Li; Ratner, Nan Bernstein; Gkalitsiou, Zoi

    2015-02-01

    This study used a false memory paradigm to explore the veridical and false recall of adults who stutter. Twelve adults who stutter and 12 age-matched typically fluent peers listened to and then verbally recalled lists of words that consisted of either semantic or phonological associates or an equal number of semantic and phonological associates (i.e., hybrid condition) of a single, unpresented critical "lure" word. Three parameters of recall performance were measured across these 3 conditions: (a) number of accurately recalled words, (b) order of recall (primacy vs. recency effect), and (c) number of critical lures produced (i.e., false memories). Significant group differences were noted in recall accuracy specific to list type and also list position as well as relative to critical lure productions. Results suggest that certain basic memory processes (i.e., recency effect) and the processing of gist semantic information are largely intact in adults who stutter, but recall of verbatim phonological information and subvocal rehearsal may be deficient.

  5. The prevalence of positive reactions in the atopy patch test with aeroallergens and food allergens in subjects with atopic eczema: a European multicenter study.

    Science.gov (United States)

    Darsow, U; Laifaoui, J; Kerschenlohr, K; Wollenberg, A; Przybilla, B; Wüthrich, B; Borelli, S; Giusti, F; Seidenari, S; Drzimalla, K; Simon, D; Disch, R; Borelli, S; Devillers, A C A; Oranje, A P; De Raeve, L; Hachem, J-P; Dangoisse, C; Blondeel, A; Song, M; Breuer, K; Wulf, A; Werfel, T; Roul, S; Taieb, A; Bolhaar, S; Bruijnzeel-Koomen, C; Brönnimann, M; Braathen, L R; Didierlaurent, A; André, C; Ring, J

    2004-12-01

    The atopy patch test (APT) was proposed to evaluate IgE-mediated sensitizations in patients with atopic eczema (AE). The prevalence and agreement with clinical history and specific IgE (sIgE) of positive APT reactions was investigated in six European countries using a standardized method. A total of 314 patients with AE in remission were tested in 12 study centers on clinically uninvolved, non-abraded back skin with 200 index of reactivity (IR)/g of house dust mite Dermatophagoides pteronyssinus, cat dander, grass, and birch pollen allergen extracts with defined major allergen contents in petrolatum. Extracts of egg white, celery and wheat flour with defined protein content were also patch tested. APT values were evaluated at 24, 48, and 72 h according to the European Task Force on Atopic Dermatitis (ETFAD) guidelines. In addition, skin-prick test (SPT) and sIgE and a detailed history on allergen-induced eczema flares were obtained. Previous eczema flares, after contact with specific allergens, were reported in 1% (celery) to 34% (D. pteronyssinus) of patients. The frequency of clear-cut positive APT reactions ranged from 39% with D. pteronyssinus to 9% with celery. All ETFAD intensities occured after 48 and 72 h. Positive SPT (16-57%) and elevated sIgE (19-59%) results were more frequent. Clear-cut positive APT with all SPT and sIgE testing negative was seen in 7% of the patients, whereas a positive APT without SPT or sIgE for the respective allergen was seen in 17% of the patients. APT, SPT and sIgE results showed significant agreement with history for grass pollen and egg white (two-sided Pr > /Z/ atopic controls, no positive APT reaction was seen. Aeroallergens and food allergens are able to elicit eczematous skin reactions after epicutaneous application. As no gold standard for aeroallergen provocation in AE exists, the relevance of aeroallergens for AE flares may be evaluated by APT in addition to SPT and sIgE. The data may contribute to the international

  6. Licensing of safety critical software for nuclear reactors. Common position of seven European nuclear regulators and authorised technical support organisations

    International Nuclear Information System (INIS)

    2007-01-01

    The major result of the work is the identification of consensus and common technical positions on a set of important licensing issues raised by the design and operation of computer-based systems used in Nuclear Power Plants for safety functions. The purpose is to introduce greater consistency and more mutual acceptance into current practices. To achieve these common positions, detailed consideration was paid to the licensing approaches followed in the different countries represented by the experts of the task force. The report is intended to be useful: - to coordinate regulators' and safety experts' technical viewpoints in the design of regulators' national policies and in revisions of guidelines; - as a reference in safety cases and demonstrations of safety of software based systems; - as guidance for system design specifications by manufacturers and major I and C suppliers on the international market. The task force decided at an early stage to focus attention on computer based systems used in Nuclear Power Plants for the implementation of safety functions; namely, those systems classified by the IAEA as 'Safety Systems'. Therefore, recommendations of this report - except those of chapter 1.11 - primarily address 'safety systems' and not 'safety related systems'. It was felt that the most difficult aspects of the licensing of digital programmable systems are rooted in the specific properties of the technology. The objective was therefore to delineate practical and technical licensing guidance, rather than discussing or proposing basic principles or requirements. The design requirements and the basic principles of nuclear safety in force in each member state are assumed to remain applicable. This report represents the consensus view achieved by the experts who contributed to the task force. It is the result of what was at the time of its initiation a first attempt at the international level to achieve consensus among nuclear regulators on practical methods for

  7. 10 CFR 851.23 - Safety and health standards.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Safety and health standards. 851.23 Section 851.23 Energy DEPARTMENT OF ENERGY WORKER SAFETY AND HEALTH PROGRAM Specific Program Requirements § 851.23 Safety and..., “Marine Terminals.” (6) Title 29 CFR, Part 1918, “Safety and Health Regulations for Longshoring.” (7...

  8. 14 CFR 25.303 - Factor of safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Factor of safety. 25.303 Section 25.303... STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure General § 25.303 Factor of safety. Unless otherwise specified, a factor of safety of 1.5 must be applied to the prescribed limit load which are considered...

  9. 14 CFR 29.303 - Factor of safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Factor of safety. 29.303 Section 29.303... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Strength Requirements General § 29.303 Factor of safety. Unless otherwise provided, a factor of safety of 1.5 must be used. This factor applies to external and inertia...

  10. 14 CFR 27.303 - Factor of safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Factor of safety. 27.303 Section 27.303... STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements General § 27.303 Factor of safety. Unless otherwise provided, a factor of safety of 1.5 must be used. This factor applies to external and inertia...

  11. 9 CFR 113.33 - Mouse safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Mouse safety tests. 113.33 Section 113.33 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Procedures § 113.33 Mouse safety tests. One of the mouse safety tests provided in this section shall be...

  12. 49 CFR 238.229 - Safety appliances-general.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety appliances-general. 238.229 Section 238.229... Equipment § 238.229 Safety appliances—general. (a) Except as provided in this part, all passenger equipment continues to be subject to the safety appliance requirements contained in Federal statute at 49 U.S.C...

  13. Seismic analysis of control and safety rod drive mechanism

    International Nuclear Information System (INIS)

    Meher Prasad, A.; Jaya, K.P.; Chellapandi, P.; Rajan Babu, V.; Selvaraj, T.

    2003-01-01

    Control rod and its driving mechanism for a Fast Breeder Reactor is to facilitate safe shutdown of the reactor in case of emergency. A theoretical study on the seismic qualification of control and safety rod driving mechanism is carried out. Earthquake excitations under Operational Basis (ORE) and Safe Shutdown condition (SSE) are considered. The time required for the control rod to reach the bottom position in order to shut down the reaction under excited condition is traced out. The maximum displaced positions and extreme stresses in various parts of the system under excitations are evaluated. The system modeled using beam elements. The connections between different parts are modeled through rigid elements. The interaction between various parts are modeled using GAP elements. (author)

  14. 46 CFR 129.220 - Basic safety.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Basic safety. 129.220 Section 129.220 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS General Requirements § 129.220 Basic safety. (a) Electrical equipment and installations must be suitable...

  15. A false sense of security: safety behaviors erode objective speech performance in individuals with social anxiety disorder.

    Science.gov (United States)

    Rowa, Karen; Paulitzki, Jeffrey R; Ierullo, Maria D; Chiang, Brenda; Antony, Martin M; McCabe, Randi E; Moscovitch, David A

    2015-05-01

    In the current study, 55 participants with a diagnosis of generalized social anxiety disorder (SAD), 23 participants with a diagnosis of an anxiety disorder other than SAD with no comorbid SAD, and 50 healthy controls completed a speech task as well as self-reported measures of safety behavior use. Speeches were videotaped and coded for global and specific indicators of performance by two raters who were blind to participants' diagnostic status. Results suggested that the objective performance of people with SAD was poorer than that of both control groups, who did not differ from each other. Moreover, self-reported use of safety behaviors during the speech strongly mediated the relationship between diagnostic group and observers' performance ratings. These results are consistent with contemporary cognitive-behavioral and interpersonal models of SAD and suggest that socially anxious individuals' performance skills may be undermined by the use of safety behaviors. These data provide further support for recommendations from previous studies that the elimination of safety behaviors ought to be a priority in cognitive behavioral therapy for SAD. Copyright © 2014. Published by Elsevier Ltd.

  16. Polymer reaction engineering, an integrated approach

    NARCIS (Netherlands)

    Meyer, T.; Keurentjes, J.T.F.; Meyer, T.; Keurentjes, J.T.F.

    2005-01-01

    Summary This chapter contains sections titled: Polymer Materials A Short History of Polymer Reaction Engineering The Position of Polymer Reaction Engineering Toward Integrated Polymer Reaction Engineering The Disciplines in Polymer Reaction Engineering The Future: Product-inspired Polymer Reaction

  17. 42 CFR 3.212 - Nonidentification of patient safety work product.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Nonidentification of patient safety work product. 3... PROVISIONS PATIENT SAFETY ORGANIZATIONS AND PATIENT SAFETY WORK PRODUCT Confidentiality and Privilege Protections of Patient Safety Work Product § 3.212 Nonidentification of patient safety work product. (a...

  18. Corporate financial decision-makers' perceptions of workplace safety.

    Science.gov (United States)

    Huang, Yueng-Hsiang; Leamon, Tom B; Courtney, Theodore K; Chen, Peter Y; DeArmond, Sarah

    2007-07-01

    This study, through a random national survey, explored how senior financial executives or managers (those who determined high-level budget, resource allocation, and corporate priorities) of medium-to-large companies perceive important workplace safety issues. The three top-rated safety priorities in resource allocation reported by the participants (overexertion, repetitive motion, and bodily reaction) were consistent with the top three perceived causes of workers' compensation losses. The greatest single safety concerns reported were overexertion, repetitive motion, highway accidents, falling on the same level and bodily reaction. A majority of participants believed that the indirect costs associated with workplace injury were higher than the direct costs. Our participants believed that money spent improving workplace safety would have significant returns. The perceived top benefits of an effective workplace safety program were increased productivity, reduced cost, retention, and increased satisfaction among employees. The perceived most important safety modification was safety training. The top reasons senior financial executives gave for believing their safety programs were better than those at other companies were that their companies paid more attention to and emphasized safety, they had better classes and training focused on safety, and they had teams/individuals focused specifically on safety.

  19. 14 CFR 153.5 - Aviation safety inspector airport access.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Aviation safety inspector airport access... TRANSPORTATION (CONTINUED) AIRPORTS AIRPORT OPERATIONS Aviation Safety Inspector Access § 153.5 Aviation safety... must grant Aviation Safety Inspectors bearing FAA Form 110A free and uninterrupted access to public-use...

  20. 47 CFR 80.1133 - Transmission of safety communications.

    Science.gov (United States)

    2010-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating... safety traffic frequencies specified in § 80.1077, or via the maritime mobile satellite service or on... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmission of safety communications. 80.1133...

  1. 33 CFR 147.801 - Boxer Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Boxer Platform safety zone. 147.801 Section 147.801 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.801 Boxer Platform safety zone. (a...

  2. Safety Bulletin 2014-2

    CERN Multimedia

    HSE Unit

    2014-01-01

    The HSE Unit would like to inform you that the Safety Bulletin 2014-2 entitled “False floors: real dangers” has just been released.     The Bulletin is available on EDMS under the following number: 1366385. We would like to remind you that HSE Safety Bulletins are published in English and French and incorporate feedback from incidents/near misses/accidents that have occurred on the CERN site, with the aim of improving prevention. We remain at your disposal in case you have further questions: safety.bulletin@cern.ch.

  3. Investigation of safety margin for turbine generator foundation affected by Alkali Silica reaction based on non-linear structure analysis

    International Nuclear Information System (INIS)

    Shimizu, H.; Asai, Y.; Hosokawa, T.; Sekimoto, H.; Sato, K.; Oshima, R.; Takiguchi, K.; Masuda, Y.; Nishiguchi, I.

    2005-01-01

    A turbine generator foundation is a reinforced concrete structure having a table deck and columns to support equipments. After operation of the plant, the expansion of the table deck in turbine longitudinal axis has been observed. By investigation of concrete material properties, it was found that the expansion has been caused by alkali-silica reaction. This study has been performed to evaluate the safety allowance of strength capacity of the turbine generator foundation by nonlinear analysis using beam element model with elongation, rebar strain and material properties data which have been measured for almost 30 years in actual foundation. (authors)

  4. 40 CFR 258.10 - Airport safety.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Airport safety. 258.10 Section 258.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Location Restrictions § 258.10 Airport safety. (a) Owners or operators of new...

  5. False memory in aging: effects of emotional valence on word recognition accuracy.

    Science.gov (United States)

    Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne

    2008-06-01

    Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.

  6. Viewing loved faces inhibits defense reactions: a health-promotion mechanism?

    Directory of Open Access Journals (Sweden)

    Pedro Guerra

    Full Text Available We have known for decades that social support is associated with positive health outcomes. And yet, the neurophysiological mechanisms underlying this association remain poorly understood. The link between social support and positive health outcomes is likely to depend on the neurophysiological regulatory mechanisms underlying reward and defensive reactions. The present study examines the hypothesis that emotional social support (love provides safety cues that activate the appetitive reward system and simultaneously inhibit defense reactions. Using the startle probe paradigm, 54 undergraduate students (24 men viewed black and white photographs of loved (romantic partner, father, mother, and best friend, neutral (unknown, and unpleasant (mutilated faces. Eye-blink startle, zygomatic major activity, heart rate, and skin conductance responses to the faces, together with subjective ratings of valence, arousal, and dominance, were obtained. Viewing loved faces induced a marked inhibition of the eye-blink startle response accompanied by a pattern of zygomatic, heart rate, skin conductance, and subjective changes indicative of an intense positive emotional response. Effects were similar for men and women, but the startle inhibition and the zygomatic response were larger in female participants. A comparison between the faces of the romantic partner and the parent who shares the partner's gender further suggests that this effect is not attributable to familiarity or arousal. We conclude that this inhibitory capacity may contribute to the health benefits associated with social support.

  7. Viewing loved faces inhibits defense reactions: a health-promotion mechanism?

    Science.gov (United States)

    Guerra, Pedro; Sánchez-Adam, Alicia; Anllo-Vento, Lourdes; Ramírez, Isabel; Vila, Jaime

    2012-01-01

    We have known for decades that social support is associated with positive health outcomes. And yet, the neurophysiological mechanisms underlying this association remain poorly understood. The link between social support and positive health outcomes is likely to depend on the neurophysiological regulatory mechanisms underlying reward and defensive reactions. The present study examines the hypothesis that emotional social support (love) provides safety cues that activate the appetitive reward system and simultaneously inhibit defense reactions. Using the startle probe paradigm, 54 undergraduate students (24 men) viewed black and white photographs of loved (romantic partner, father, mother, and best friend), neutral (unknown), and unpleasant (mutilated) faces. Eye-blink startle, zygomatic major activity, heart rate, and skin conductance responses to the faces, together with subjective ratings of valence, arousal, and dominance, were obtained. Viewing loved faces induced a marked inhibition of the eye-blink startle response accompanied by a pattern of zygomatic, heart rate, skin conductance, and subjective changes indicative of an intense positive emotional response. Effects were similar for men and women, but the startle inhibition and the zygomatic response were larger in female participants. A comparison between the faces of the romantic partner and the parent who shares the partner's gender further suggests that this effect is not attributable to familiarity or arousal. We conclude that this inhibitory capacity may contribute to the health benefits associated with social support.

  8. 42 CFR 3.204 - Privilege of patient safety work product.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Privilege of patient safety work product. 3.204... PROVISIONS PATIENT SAFETY ORGANIZATIONS AND PATIENT SAFETY WORK PRODUCT Confidentiality and Privilege Protections of Patient Safety Work Product § 3.204 Privilege of patient safety work product. (a) Privilege...

  9. Positive patch test reactions to oxidized limonene: exposure and relevance.

    Science.gov (United States)

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Gimenez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2014-11-01

    R-Limonene is a common fragrance terpene found in domestic and industrial products. R-Limonene autoxidizes on air exposure, and the oxidation products can cause contact allergy. In a recent multicentre study, 5.2% (range 2.3-12.1%) of 2900 patients showed a positive patch test reaction to oxidized R-limonene. To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. Oxidized R-limonene 3.0% (containing limonene hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. Overall, exposure to products containing limonene was found and assessed as being probably relevant for the patients' dermatitis in 36% of the limonene-allergic patients. In Barcelona and Copenhagen, > 70% of the patients were judged to have had an exposure to limonene assessed as relevant. Oxidized R-limonene is a common fragrance allergen, and limonene was frequently found in the labelling on the patients' products, and assessed as relevant for the patients' dermatitis. A large number of domestic and occupational sources for contact with R-limonene were identified. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Investigation of Na-CO{sub 2} Reaction with Initial Reaction in Various Reacting Surface

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Su; Park, Gunyeop; Kim, Soo Jae; Park, Hyun Sun; Kim, Moo Hwan [POSTECH, Pohang (Korea, Republic of); Wi, Myung-Hwan [KAERI, Daejeon (Korea, Republic of)

    2015-10-15

    The reaction products that cause oxidation and erosion are threaten the heat transfer tubes so that it is necessary to investigate Na-CO{sub 2} reaction according to various experimental parameter. Unlike SWR, Na-CO{sub 2} reaction is more complex to deal with reaction kinetics. Since a comprehensive understanding of Na-CO{sub 2} reaction mechanism is crucial for the safety analysis, the reaction phenomenon under the various conditions was investigated. The current issue is to make a database for developing computational code for CO{sub 2} gas leak situation because it is experimentally difficult to analyze the actual accident situation. Most studies on Na-CO{sub 2} interaction reports that chemical reaction is getting vigorous as temperature increased and reactivity is sensitive as temperature change between 400 .deg. C and 600 .deg. C. Therefore, temperature range is determined based on the operating condition (450 - 500 .deg. C) of KALIMER-600 employed as supercritical CO{sub 2} brayton cycle energy conversion system for Na-CO{sub 2} heat exchanger. And next parameter is sodium surface area which contact between sodium and CO{sub 2} when CO{sub 2} is injected into sodium pool in the accident situation. So, the fundamental surface reaction is experimentally studied in the range of 8 - 12cm{sup 2}. Additionally, it has been reported in recent years that CO{sub 2} Flow rate affects reactivity less significantly and CO{sub 2} flow rate is assumed that 5 SLPM (standard liter per minute) is suitable as a basis for a small leakage. The finally selected control parameters is sodium temperature and reacting surface area with constant CO{sub 2} flow rate. Na-CO{sub 2} reaction test is performed for investigating risk of potential accident which contacts with liquid sodium and CO{sub 2}. Amount of reaction is saturated as time passed because of kept a balance between production of solid phase reaction products and amount of diffusivity. These results contribute to make a

  11. 9 CFR 113.40 - Dog safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dog safety tests. 113.40 Section 113... Procedures § 113.40 Dog safety tests. The safety tests provided in this section shall be conducted when... recommended for use in dogs. Serials which are not found to be satisfactory when tested pursuant to the...

  12. Teacher Education and the Enduring Significance of "False Empathy"

    Science.gov (United States)

    Warren, Chezare A.; Hotchkins, Bryan K.

    2015-01-01

    The concept "False Empathy" posited by critical race theory luminary Richard Delgado ("Calif Law Rev" 84(1):61-100, 1996) easily obscures White teacher's good intentions to be effective educators of racially, culturally, and linguistically diverse students. It is argued here that critical race theory is useful for isolating and…

  13. 29 CFR 1925.2 - Safety and health standards.

    Science.gov (United States)

    2010-07-01

    .... Every contractor and subcontractor shall comply with the safety and health standards published in 41 CFR... 29 Labor 7 2010-07-01 2010-07-01 false Safety and health standards. 1925.2 Section 1925.2 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...

  14. 31 CFR 538.519 - Aircraft and maritime safety.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Aircraft and maritime safety. 538.519..., Authorizations, and Statements of Licensing Policy § 538.519 Aircraft and maritime safety. Specific licenses may... aircraft, and to ensure the safety of ocean-going maritime traffic in international waters. ...

  15. 32 CFR 989.27 - Occupational safety and health.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Occupational safety and health. 989.27 Section... PROTECTION ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.27 Occupational safety and health. Assess direct and indirect impacts of proposed actions on the safety and health of Air Force employees and...

  16. 49 CFR 238.230 - Safety appliances-new equipment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety appliances-new equipment. 238.230 Section... I Passenger Equipment § 238.230 Safety appliances—new equipment. (a) Applicability. This section..., 2007, that is equipped with a safety appliance, required by the “manner of application” provisions in...

  17. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne; Dachman, Abraham H.

    2006-01-01

    One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs may distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture

  18. 49 CFR 385.313 - Who will conduct the safety audit?

    Science.gov (United States)

    2010-10-01

    ... FITNESS PROCEDURES New Entrant Safety Assurance Program § 385.313 Who will conduct the safety audit? An individual certified under the FMCSA regulations to perform safety audits will conduct the safety audit. ... 49 Transportation 5 2010-10-01 2010-10-01 false Who will conduct the safety audit? 385.313 Section...

  19. Mouse obesity network reconstruction with a variational Bayes algorithm to employ aggressive false positive control

    Directory of Open Access Journals (Sweden)

    Logsdon Benjamin A

    2012-04-01

    Full Text Available Abstract Background We propose a novel variational Bayes network reconstruction algorithm to extract the most relevant disease factors from high-throughput genomic data-sets. Our algorithm is the only scalable method for regularized network recovery that employs Bayesian model averaging and that can internally estimate an appropriate level of sparsity to ensure few false positives enter the model without the need for cross-validation or a model selection criterion. We use our algorithm to characterize the effect of genetic markers and liver gene expression traits on mouse obesity related phenotypes, including weight, cholesterol, glucose, and free fatty acid levels, in an experiment previously used for discovery and validation of network connections: an F2 intercross between the C57BL/6 J and C3H/HeJ mouse strains, where apolipoprotein E is null on the background. Results We identified eleven genes, Gch1, Zfp69, Dlgap1, Gna14, Yy1, Gabarapl1, Folr2, Fdft1, Cnr2, Slc24a3, and Ccl19, and a quantitative trait locus directly connected to weight, glucose, cholesterol, or free fatty acid levels in our network. None of these genes were identified by other network analyses of this mouse intercross data-set, but all have been previously associated with obesity or related pathologies in independent studies. In addition, through both simulations and data analysis we demonstrate that our algorithm achieves superior performance in terms of power and type I error control than other network recovery algorithms that use the lasso and have bounds on type I error control. Conclusions Our final network contains 118 previously associated and novel genes affecting weight, cholesterol, glucose, and free fatty acid levels that are excellent obesity risk candidates.

  20. The effects of increasing semantic-associate list length on the Deese-Roediger-McDermott false recognition memory: Dual false-memory process in retrieval from sub- and supraspan lists.

    Science.gov (United States)

    Jou, Jerwen; Arredondo, Mario L; Li, Cheng; Escamilla, Eric E; Zuniga, Richard

    2017-10-01

    In this study, the number of semantic associates in Deese-Roediger-McDermott (DRM) lists was varied from 4 to 14 in a modified Sternberg paradigm. The false alarm (FA) and correct rejection (CR) reaction time (RT)/memory-set size (MSS) functions of critical lures showed a cross-over interaction at approximately MSS 7, suggesting a reversal of the relative dominance between these two responses to the critical lure at this point and also indicating the location of the boundary between the sub- and supraspan MSS. For the subspan lists, FA to critical lures was slower than CR, suggesting a slow, strategic mechanism driving the false memory. Conversely, for the supraspan lists, critical lure FA was faster than its CR, suggesting a spontaneous mechanism driving the false memory. Results of two experiments showed that an automatic, fast, and a slow, controlled process could be error-prone or error-corrective, depending on the length of the DRM memory list. Thus there is a dual retrieval process in false memory as in true memory. The findings can be explained by both the activation/monitoring and the fuzzy-trace theories.