WorldWideScience

Sample records for safe standby condition

  1. Placement of the radiochemical processing plant at Oak Ridge National Laboratory into a safe standby condition

    International Nuclear Information System (INIS)

    Holladay, D.W.; Bopp, C.D.; Farmer, A.J.; Johnson, J.K.; Miller, C.H.; Powers, B.A.; Collins, E.D.

    1986-01-01

    Extensive upgrade, cleanup, and decontamination efforts are being conducted for appropriate areas in the Radiochemical Processing Plant (RPP) with the goal of achieving safe standby condition by the end of FY 1989. The ventilation system must maintain containment thus, it is being upgraded via demolition and replacement of marginally adequate ductwork, fans, and control systems. Areas that are being decontaminated and stripped of various services (e.g., piping, ductwork, and process tanks) include hot cells, makeup rooms, and pipe tunnels. Operating equipment that is being decontaminated includes glove boxes and hoods. Replacement of the ventilation system and removal of equipment from pipe tunnels, cells, and makeup rooms are accomplished by contact labor by workers using proper attire, safety rules, and shielding, Removal of contaminated ductwork and piping is conducted with containment enclosures that are strategically located at breakpoints, and methods of separation are chosen to conform with health physics requirements. The methods of cutting contaminated piping and ductwork include portable reciprocating saws, pipe cutters, burning, and plasma torch. Specially designed containment enclosures will be used to prevent the spread of radioactive contamination while maintaining adequate ventilation

  2. Placement of the radiochemical processing plant at Oak Ridge National Laboratory into a safe standby condition

    International Nuclear Information System (INIS)

    Holladay, D.W.; Bopp, C.D.; Farmer, A.J.; Johnson, J.K.; Miller, C.H.; Powers, B.A.; Collins, E.D.

    1986-01-01

    Extensive upgrade, cleanup, and decontamination efforts are being conducted for appropriate areas in the Radiochemical Processing Plant (RPP) with the goal of achieving ''safe standby'' condition by the end of FY 1989. The ventilation system must maintain containment; thus, it is being upgraded via demolition and replacement of marginally adequate ductwork, fans, and control systems. Areas that are being decontaminated and stripped of various services (e.g., piping, ductwork, and process tanks) include hot cells, makeup rooms, and pipe tunnels. Operating equipment that is being decontaminated includes glove boxes and hoods. Replacement of the ventilation system and removal of equipment from pipe tunnels, cells, and makeup rooms are accomplished by contact labor by workers using proper attire, safety rules, and shielding. Removal of contaminated ductwork and piping is conducted with containment enclosures that are strategically located at breakpoints, and methods of separation are chosen to conform with health physics requirements. The methods of cutting contaminated piping and ductwork include portable reciprocating saws, pipe cutters, burning, and plasma torch. Specially designed containment enclosures will be used to prevent the spread of radioactive contamination while maintaining adequate ventilation. 6 figs

  3. Development of condition monitoring and diagnosis system for standby diesel generator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwang Hee; Park, Jong Hyuck; Park, Jong Eun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The emergency diesel generator (EDG) of the nuclear power plant is designed to supply the power to the nuclear on Station Black Out (SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a condition monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developed the online condition monitoring and diagnosis system for the wolsong unit 3 and 4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring and diagnosis system (SDG MDS) for the wolsong standby diesel generator are described. By using the condition monitoring module of the SDG MDS, performance monitoring function for major operating parameters of EDG reliability program required by Reg. guide 1.155 can be operated as on line monitoring system.

  4. Development of condition monitoring and diagnosis system for standby diesel generator

    International Nuclear Information System (INIS)

    Choi, Kwang Hee; Park, Jong Hyuck; Park, Jong Eun

    2009-01-01

    The emergency diesel generator (EDG) of the nuclear power plant is designed to supply the power to the nuclear on Station Black Out (SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a condition monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developed the online condition monitoring and diagnosis system for the wolsong unit 3 and 4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring and diagnosis system (SDG MDS) for the wolsong standby diesel generator are described. By using the condition monitoring module of the SDG MDS, performance monitoring function for major operating parameters of EDG reliability program required by Reg. guide 1.155 can be operated as on line monitoring system

  5. Fast Flux Test Facility (FFTF) standby plan

    Energy Technology Data Exchange (ETDEWEB)

    Hulvey, R.K.

    1997-03-06

    The FFTF Standby Plan, Revision 0, provides changes to the major elements and project baselines to maintain the FFTF plant in a standby condition and to continue washing sodium from irradiated reactor fuel. The Plan is consistent with the Memorandum of Decision approved by the Secretary of Energy on January 17, 1997, which directed that FFTF be maintained in a standby condition to permit the Department to make a decision on whether the facility should play a future role in the Department of Energy`s dual track tritium production strategy. This decision would be made in parallel with the intended December 1998 decision on the selection of the primary, long- term source of tritium. This also allows the Department to review the economic and technical feasibility of using the FFTF to produce isotopes for the medical community. Formal direction has been received from DOE-RL and Fluor 2020 Daniel Hanford to implement the FFTF standby decision. The objective of the Plan is maintain the condition of the FFTF systems, equipment and personnel to preserve the option for plant restart within three and one-half years of a decision to restart, while continuing deactivation work which is consistent with the standby mode.

  6. Fast Flux Test Facility (FFTF) standby plan

    International Nuclear Information System (INIS)

    Hulvey, R.K.

    1997-01-01

    The FFTF Standby Plan, Revision 0, provides changes to the major elements and project baselines to maintain the FFTF plant in a standby condition and to continue washing sodium from irradiated reactor fuel. The Plan is consistent with the Memorandum of Decision approved by the Secretary of Energy on January 17, 1997, which directed that FFTF be maintained in a standby condition to permit the Department to make a decision on whether the facility should play a future role in the Department of Energy's dual track tritium production strategy. This decision would be made in parallel with the intended December 1998 decision on the selection of the primary, long- term source of tritium. This also allows the Department to review the economic and technical feasibility of using the FFTF to produce isotopes for the medical community. Formal direction has been received from DOE-RL and Fluor 2020 Daniel Hanford to implement the FFTF standby decision. The objective of the Plan is maintain the condition of the FFTF systems, equipment and personnel to preserve the option for plant restart within three and one-half years of a decision to restart, while continuing deactivation work which is consistent with the standby mode

  7. Standby-Loss Elimination in Server Power Supply

    Directory of Open Access Journals (Sweden)

    Jong-Woo Kim

    2017-07-01

    Full Text Available In a server power system, a standby converter is required in order to provide the standby output, monitor the system’s status, and communicate with the server power system. Since these functions are always required, losses from the standby converter are produced even though the system operates in normal mode. For these reasons, the losses deteriorate the total efficiency of the system. In this paper, a new structure is proposed to eliminate the losses from the standby converter of a server power supply. The key feature of the proposed structure is that the main direct current (DC/DC converter substitutes all of the output power of the standby converter, and the standby converter is turned off in normal mode. With the proposed structure, the losses from the standby converter can be eliminated in normal mode, and this leads to a higher efficiency in overall load conditions. Although the structure has been proposed in the previous work, very important issues such as a steady state analysis, the transient responses, and how to control the standby converter are not discussed. This paper presents these issues further. The feasibility of the proposed structure has been verified with 400 V link voltage, 12 V/62.5 A main output, and a 12 V/2.1 A standby output server power system.

  8. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    International Nuclear Information System (INIS)

    Christie, B.

    1996-01-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. open-quotes Conditional Probabilitiesclose quotes of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps

  9. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christie, B.

    1996-12-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. {open_quotes}Conditional Probabilities{close_quotes} of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps.

  10. Standby-consumption in households; Standby-Verbrauch im Haushalt

    Energy Technology Data Exchange (ETDEWEB)

    Zehnder, U.

    2006-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study made in five types of housing on the standby-consumption of various household appliances. 461 measurements were made in 37 households, whereby three modes - ready-for-use, standby and sleep - were examined. 71 different appliances were looked at in six consumer groups. These included entertainment, hygiene/health, kitchen/household, communication, office and garage. Data is presented in tabular form and commented on.

  11. Standby: where are we now?

    International Nuclear Information System (INIS)

    Meier, Alan

    2005-01-01

    Organised efforts to measure and reduce standby power use have been under way for about a decade. Recent measurements of homes in developed countries show that standby ranges from 60 to 110 W per home, which corresponds to about 4-11% of residential electricity use. Standby in most European homes lies between 50 W and 70 W, with countries such as Denmark at the higher end and Greece at the lower end. Some evidence suggests that these levels have risen rapidly in the past few years as a result of purchases of computers, set-top boxes, and digital appliances. Few data exist for commercial or industrial buildings but standby may be as much as 0.7 W/m 2 of floor area. About ten voluntary programmes to reduce standby are under way around the world. Three mandatory programmes to limit standby are already scheduled to go into force in 2006-2008, with others likely to follow. A horizontal standard limiting standby in all products would appear to be the most sensible policy but the rising energy use in other low-power modes must also be addressed

  12. Whole-house measurements of standby power consumption

    International Nuclear Information System (INIS)

    Ross, J.P.; Meier, Alan

    2000-01-01

    We investigated the variation in standby power consumption in ten California homes. Total standby power in the homes ranged from 14-169W, with an average of 67 W. This corresponded to 5 percent-26 percent of the homes' annual electricity use. The appliances with the largest standby losses were televisions, set-top boxes and printers. The large variation in the standby power of appliances providing the same service demonstrates that manufacturers are able to reduce standby losses without degrading performance. Replacing existing units with appliances with 1 W or less of standby power would reduce standby losses by 68 percent

  13. Global implications of standby power use

    Energy Technology Data Exchange (ETDEWEB)

    Lebot, Benoit; Meier, Alan; Anglade, Alain

    2000-05-01

    Separate studies indicate that standby power is responsible for 20-60 W per home in developed countries. Standby power is responsible for about 2% of OECD countries total electricity consumption and the related power generation generates almost 1% of their carbon emissions. Replacement of existing appliances with those appliances having the lowest standby would reduce total standby power consumption by over 70%. The resulting reductions in carbon emissions would meet over 3% of OECD's total Kyoto commitments. Other strategies may cut more carbon emissions, but standby power is unique in that the reductions are best accomplished through international collaboration and whose costs and large benefits would be spread over all countries.

  14. 49 CFR 234.251 - Standby power.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Standby power. 234.251 Section 234.251 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Inspections and Tests § 234.251 Standby power. Standby power shall be tested at least...

  15. Reduction of standby-losses - Obstacles and how to get over them; Verminderung der Standby-Verluste. Hindernisse und Massnahmen zur Ueberwindung

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J. [Arena, Zuerich (Switzerland); Togni, G. [Togni Energie GmbH, Zuerich (Switzerland); Braunwalder, A. [Braunwalder Energie-Kommunikation, Erstfeld (Switzerland)

    2007-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at how stand-by losses in electrical devices and consumer electronics can be reduced. The project presents an inventory of appliances along with estimates of consumption levels in standby mode. This permitted the authors to identify current priority areas such as consumer electronics, PC workstations and coffee machines. Various tools and measures to be taken are also described, including the implementation of minimum requirements for reducing standby consumption. These are assessed on the basis of a variety of criteria. Implementation measures and projects are proposed that show the greatest potential for success in reducing standby power consumption. A number of implementation projects already initiated while the study was still in progress include the 'Energy City' mouse switching device, the WWF's 'Stop standby' campaign, the 'EnergyBox standby check', hints on PC configuration for standby/sleep mode, the energy-efficient coffee machines promotion campaign, and the 'Topten' list of hi-fi systems with low standby consumption. Base data and modelling methods are reported on, as are measures to be taken.

  16. Optimal design of a general warm standby system

    International Nuclear Information System (INIS)

    Yun, Won Young; Cha, Ji Hwan

    2010-01-01

    Redundancy or standby is a technique that has been widely applied to improving system reliability and availability in the stage of system design. In this paper, we consider a standby system with two units in which the first unit (unit 1) starts its operation under active state and the other unit (unit 2) is under cold standby state at the starting point. After a specified time s (switching time), the state of unit 2 is changed to warm standby state and, as soon as the operating unit 1 fails, the state of unit 2 is changed to active state. If unit 1 fails before time s, the system fails. Units can fail at both active and warm standby states. A general method for modeling the standby system is adopted and system performance measures (system reliability and mean life) based on the proposed model are derived. Three models - a perfect switching model and two imperfect switching models - are considered in this paper. Two imperfect switching models include an imperfect switching probability and a preliminary warm-up period which is required for the change from cold standby state to warm standby state. We consider the problem of determining the optimal switching time which maximizes the expected system life and related allocation problem is also discussed. Some numerical examples are studied.

  17. Standby-optimisation for existing lift installations - Final report; Standby-Optimierung bestehender Aufzugsanlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, U. [Schindler Elettronica SA, Locarno (Switzerland); Bettschen, R. [Schindler Aufzuege AG, Ebikon (Switzerland)

    2010-07-15

    There are about 180,000 elevators in Switzerland. It is interesting to know how much energy those elevators are using and to know their saving potential, if they would optimally use today's available technology. A previous final report (SFOE reference number 250057) has answered these questions. The results have been used in the work for the directive VDI 4707, which defines an energy label for elevators. It can therefore be assumed that a means has been created to have the necessary pressure to continuously improve the energy efficiency of elevators. Since elevators are products with very long lifetime, it will take a couple of decades until the older less efficient elevators got replaced by modern efficient ones. Modernizing elevators is a common practice, where usually modern drive solutions are sold. During the last years, the elevator industry has made high progress in improving the efficiency in the operation. The lack of awareness and the regulatory requirements have continuously increased the standby power. There are no solutions on the market to minimize the standby although 70% of the energy used by elevators in Switzerland count for the standby. Therefore this study has set the target to optimize the standby for existing elevators. The focus has been set to a solution being manufacturer and technology neutral, since the technology and product variations are huge. Using a standby-reduction-device, this study tries to automatically switch off complete elevators from the mains and on demand turns them on again. The study shows the problems faced, the solution chosen and the possible saving potential. As additional goal the study gives practical introduction in the instrumentation and to the energy label for elevators. (authors)

  18. Operational reliability of the Point Lepreau GS standby generators

    Energy Technology Data Exchange (ETDEWEB)

    Loughead, D. A.; McGregor, A. T. [Safety and Compllance Group, New Brunswick Electric Power Commission, Point Lepreau Generating Station, P.O.Box 10 Lepreau, New Brunswick E0G 2H0 (Canada)

    1986-02-15

    Performance of the two Point Lepreau GS standby generators during the first three years of licensed station operation is reviewed. It is shown that the mandated reliability/availability requirements have been met. The nature of starting and running failures has been examined and the consequences, in terms of design and procedural changes, discussed. A brief review of standby generator outages is included to permit estimates of standby generator availability and total Class III standby power unavailability. A pair of simple equations is introduced as a means of estimating the probable economic penalty, both cumulative and incremental, associated with the running failure of one standby generator while the other is on a maintenance outage. (authors)

  19. Operational reliability of the Point Lepreau GS standby generators

    International Nuclear Information System (INIS)

    Loughead, D.A.; McGregor, A.T.

    1986-01-01

    Performance of the two Point Lepreau GS standby generators during the first three years of licensed station operation is reviewed. It is shown that the mandated reliability/availability requirements have been met. The nature of starting and running failures has been examined and the consequences, in terms of design and procedural changes, discussed. A brief review of standby generator outages is included to permit estimates of standby generator availability and total Class III standby power unavailability. A pair of simple equations is introduced as a means of estimating the probable economic penalty, both cumulative and incremental, associated with the running failure of one standby generator while the other is on a maintenance outage. (authors)

  20. Reliability analysis of a complex standby redundant systems

    International Nuclear Information System (INIS)

    Subramanian, R.; Anantharaman, V.

    1995-01-01

    In any redundant system, the state of the standby unit is usually taken to be hot, warm or cold. In this paper, we present a new model of a two unit standby system wherein the standby unit is put in cold state for a certain amount of time before it is allowed to become warm. Upon failure of the online unit, the standby unit, if in warm state, instantaneously starts operating online; if it is in cold state, an emergency switching is made which takes it to warm state (and hence online) either instantaneously or non-instantaneously--each with some probability; if it is under repair, the system breaks down. Assuming all the associated distributions to be general except that of the life time of the standby unit in the warm state, various reliability characteristics that are of interest to reliability engineers and system designers are derived. A comprehensive cost function is also constructed and is then optimized with respect to three different control parameters numerically. In addition numerical results are presented to illustrate the behaviour of the various reliability characteristics derived

  1. Methodology development for availability improvement of standby equipment

    International Nuclear Information System (INIS)

    Shin, Sung Min; Jeon, In Seop; Kang, Hyun Gook

    2014-01-01

    The core damage frequency (CDF) of operating and constructing pressurized nuclear plants are ranging on the order of 10 -5 and 10 -6 per year. The target CDF of new NPP design has been set at 10 -7 . In this context, although various systems are currently studied, availability improvement of standby equipment will be more efficient than the additional application of safety systems. It is obvious in every aspect, such as management and cost efficiency. Here, soundness can affect equipment unavailability, and the soundness degrades because of aging. However, some studies did not consider aging when calculating the unavailability. Standby equipment can age because of two important factors: standby stress which accumulates over time, and test stress which accumulates with the number of tests (or operations). Both factors should be considered together when aging is considered. However, some studies only considered standby stress or test stress. There are some previous studies which considered both factors. Besides equipment soundness related to aging effect, some process like bypass during test also can affect equipment unavailability because the original function of equipment cannot be performed immediately during this process. However, there are seldom studies dealing with above factors as a whole problem. This study investigated a general approach to calculate the unavailability of standby equipment which considers aging caused by standby and test stresses and bypass process. Based on this general approach, we propose two maintenance strategies which aim to reduce standby equipment unavailability. In section 2, the general approach is presented. As one of the strategies, the changing test interval method (CIM) is introduced in section 3, and its effectiveness is also analyzed. The online monitoring method (OMM) is investigated in section 4 as another method to reduce equipment unavailability. In section 5, a combination of these two methods is analyzed. A general

  2. Survey on queueing models with standbys support

    Directory of Open Access Journals (Sweden)

    Kolledath Sreekanth

    2018-01-01

    Full Text Available This paper is a survey article on queueing models with standbys support. Due to many real life applications of queueing models, it has become an interesting area for researchers and a lot of research work has been exerted so far. It is worthwhile to examine the performance based analysis for queueing modelling system as it provides a valuable insight to the tractability of the system and accelerates its efficiency. The provision of standbys to the queueing modelling of a real system is needed for smooth functioning in the presence of its unavoidable failures. The present survey provides a dig into the research work done, and emphasis the sequential developments on queueing models with standbys support.

  3. Simulation of Standby Efficiency Improvement for a Line Level Control Resonant Converter Based on Solar Power Systems

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2015-01-01

    Full Text Available This paper proposes a new scheme to improve the standby efficiency of the high-power half-bridge line level control (LLC resonant converter. This new circuit is applicable to improving the efficiency of the renewable energy generation system in distributed power systems. The main purpose is to achieve high-efficiency solar and wind power and stable output under different load conditions. In comparison with the traditional one, this novel method can improve standby efficiency at standby. The system characteristics of this proposed method have been analyzed through detailed simulations, which prove its feasibility.

  4. Should the next standby power target be 0-watt?

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Siderius, Hans-Paul [Rijksdienst voor Ondernemend (Netherlands)

    2017-06-29

    The standby power use of appliances continues to consume large amounts of electricity. Considerable success has been made in reducing each device’s use, but these savings have been offset by a huge increase in the number of products using standby power and new power requirements for maintaining network connections. Current strategies to reduce standby have limitations and may not be most appropriate for emerging energy consumption trends. A new strategy for further reductions in standby, the “Standzero” option, encourages electrical products to be designed to operate for short periods without relying on mains-supplied electricity. Energy savings are achieved through enhanced efficiency and by harvesting ambient energy. A sensitivity analysis suggests many appliances could be designed to operate for at least an hour without relying on mains power and, in some cases, may be able to operate indefinitely at zero watts until activated.

  5. A fast approximation method for reliability analysis of cold-standby systems

    International Nuclear Information System (INIS)

    Wang, Chaonan; Xing, Liudong; Amari, Suprasad V.

    2012-01-01

    Analyzing reliability of large cold-standby systems has been a complicated and time-consuming task, especially for systems with components having non-exponential time-to-failure distributions. In this paper, an approximation model, which is based on the central limit theorem, is presented for the reliability analysis of binary cold-standby systems. The proposed model can estimate the reliability of large cold-standby systems with binary-state components having arbitrary time-to-failure distributions in an efficient and easy way. The accuracy and efficiency of the proposed method are illustrated using several different types of distributions for both 1-out-of-n and k-out-of-n cold-standby systems.

  6. Concept for the redesign of ECOMAN (standby losses) - Final report; Konzepte fuer Redesign ECOMAN (Standby-Verluste) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, D.; Haerri, V.V.; Riesen, H.

    2008-04-15

    A lot of electronic devices are equipped with a so called standby mode. In this mode a device can easily be brought into full functionality directly, by remote control or by timer. Unfortunately, the standby mode implies a high consumption of electrical energy that could be reduced 10 to 20 times by an adequate technology. In Switzerland these losses amount to approximately 1,900 GWh. The so called ECOMAN is an electronic device which can reduce these losses effectively and comfortably. Due to political pressure the producers of electronic devices are forced to find solutions for the problem of standby losses. The ECOMAN would thus be of less importance because the problem would be solved at its roots. This fact and the wish to have a better performance led to a new definition of this device. The ECOMAN has to be improved and shall offer additional functions. E.g. it shall protect the devices from fire hazard or serve as control in the field of building automation. The new concepts were well accepted by the producer who already realized the specification of the first phase of redesign, which serves as basis for the further development of integration. (author)

  7. Revalidation program for nuclear standby diesel generators

    International Nuclear Information System (INIS)

    Muschick, R.P.

    1985-01-01

    This paper describes the program which Duke Power Company carried out to revalidate the diesel engines used in diesel generators for nuclear standby service at Unit 1 of the Catawba Nuclear Station. The diesels operated satisfactorily during the tests, and only relatively minor conditions were noted during the test and inspections, with one exception. This exception was that cracks were detected in the piston skirts. The piston skirts have been replaced with improved design skirts. The diesels have been fully revalidated for their intended service, and have been declared operable

  8. An investigation of standby energy losses in residential sector: Solutions and policies

    Energy Technology Data Exchange (ETDEWEB)

    Singh Solanki, Parmal [Caledonian (University) College of Engineering, Muscat (Oman); Sarma Mallela, Venkateswara [G. Narayanamma Institute of Technology and Science (for Women), Hyderabad (India); Zhou, Chengke [Glasgow Caledonian University, Glasgow, Scotland (United Kingdom)

    2013-07-01

    This paper investigates the standby power losses of household appliances and determines these losses by field measurements and bottom-up approaches. It is revealed that average standby power losses of e-appliances at household in Oman is 103.4 Watts and could further increase if other miscellaneous appliances are also taken into account. Calculations show that TV sets alone are responsible to consume 1.89 MW standby powers across the country. The paper considers various technological and socio-economic options to diminish the standby power consumption and signify that 42.72% of energy consumed by appliances can be saved by end-users implementing suitable measures. Energy management programmes like energy efficiency standards, labelling and policy instruments to tackle the standby power losses are also discussed. Finally, paper looks into the barriers and their way-outs to implement the energy efficiency standards and labelling.

  9. Markov analysis of different standby computer based systems

    International Nuclear Information System (INIS)

    Srinivas, G.; Guptan, Rajee; Mohan, Nalini; Ghadge, S.G.; Bajaj, S.S.

    2006-01-01

    As against the conventional triplicated systems of hardware and the generation of control signals for the actuator elements by means of redundant hardwired median circuits, employed in the early Indian PHWR's, a new approach of generating control signals based on software by a redundant system of computers is introduced in the advanced/current generation of Indian PHWR's. Reliability is increased by fault diagnostics and automatic switch over of all the loads to one computer in case of total failure of the other computer. Independent processing by a redundant CPU in each system enables inter-comparison to quickly identify system failure, in addition to the other self-diagnostic features provided. Combinatorial models such as reliability block diagrams and fault trees are frequently used to predict the reliability, maintainability and safety of complex systems. Unfortunately, these methods cannot accurately model dynamic system behavior; Because of its unique ability to handle dynamic cases, Markov analysis can be a powerful tool in the reliability maintainability and safety (RMS) analyses of dynamic systems. A Markov model breaks the system configuration into a number of states. Each of these states is connected to all other states by transition rates. It then utilizes transition matrices to evaluate the reliability and safety of the systems, either through matrix manipulation or other analytical solution methods, such as Laplace transforms. Thus, Markov analysis is a powerful reliability, maintainability and safety analysis tool. It allows the analyst to model complex, dynamic, highly distributed, fault tolerant systems that would otherwise be very difficult to model using classical techniques like the Fault tree method. The Dual Processor Hot Standby Process Control System (DPHS-PCS) and the Computerized Channel Temperature Monitoring System (CCTM) are typical examples of hot standby systems in the Indian PHWR's. While such systems currently in use in Indian PHWR

  10. Reliability Analysis of a Two Dissimilar Unit Cold Standby System ...

    African Journals Online (AJOL)

    (2009) using linear first order differential equation evaluated the reliability and availability characteristics of two-dissimilar-unit cold standby system with three mode for which no cost benefit analysis was considered. El-said (1994) contributed on stochastic analysis of a two-dissimilar-unit standby redundant system.

  11. V-1 nuclear power plant standby RPP-16S computer software

    International Nuclear Information System (INIS)

    Suchy, R.

    1988-01-01

    The software structure of the function of program modules of the RPP-16S standby computer which is part of the information system of the V-1 Bohunice nuclear power plant are described. The multitasking AMOS operational system is used for the organization of programs in the computer. The program modules are classified in five groups by function, i.e., in modules for the periodical collection of values and for the measurement of process quantities for both nuclear power plant units; for the primary processing of the values; for the monitoring of exceedance of preset limits; for unit operators' communication with the computer. The fifth group consists of users program modules. The standby computer software was tested in the actual operating conditions of the V-1 power plant. The results showed it operated correctly; minor shortcomings were removed. (Z.M.). 1 fig

  12. Review of Standby and Ancillary Services in the Context of Behind-the-Meter Photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Holm, Alison [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-25

    The New Mexico Public Regulatory Commission (NMPRC) requested information on the following topics: Overview of ancillary and standby services. Examples of how ancillary and standby services are defined, used, and analyzed in other jurisdictions. Considerations regarding how ancillary and standby services may be economically valued. Background information on how ancillary and standby services differ from fixed costs to serve owners of behind-the-meter solar photovoltaic (BTM PV) systems.

  13. Korea's 1-watt plan ''Standby Korea 2010''

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yungrae

    2010-09-15

    Korea announced standby power of all electronics shall be reduced to below 1W by 2010. Ministry of Knowledge Economy (MKE, Korean government) and Korea Energy Management Corporation (KEMCO) established ''Standby Korea 2010'' which is a roadmap to limit standby power below 1W by 2010. Korea implemented mandatory program over a relatively short period of time, incorporating the better elements from the more established national program and adding new initiatives, such as the threat of using mandatory warning label for products that fail to meet standby power targets.

  14. A reliability model of a warm standby configuration with two identical sets of units

    International Nuclear Information System (INIS)

    Huang, Wei; Loman, James; Song, Thomas

    2015-01-01

    This article presents a new reliability model and the development of its analytical solution for a warm standby redundant configuration with units that are originally operated in active mode, and then, upon turn-on of originally standby units, are put into warm standby mode. These units can be used later if a standby- turned into active-unit fails. Numerical results of an example configuration are presented and discussed with comparison to other warm standby configurations, and to Monte Carlo simulation results obtained from BlockSim software. Results show that the Monte Carlo simulation model gives virtually identical reliability value when the simulation uses a high number of replications, confirming the developed model. - Highlights: • A new reliability model is developed for a warm standby redundancy with two sets of identical units. • The units subject to state change from active to standby then back to active mode. • A closed form analytical solution is developed with exponential distribution. • To validate the developed model, a Monte Carlo simulation for an exemplary configuration is performed

  15. Allen diesel standby sets at Sellafield

    International Nuclear Information System (INIS)

    Ruff, G.

    1982-01-01

    As part of the extension and improvement plans for the British Nuclear Fuels Ltd reprocessing facilities at Sellafield, three Allen diesel engines have been installed for essential standby duty. They are 16-cylinder V-form engines with a continuous rating of 2,832 bhp and drive a 2000kW 11,000 volt 3 phase 50Hz salient pole synchronous alternator at 750r/min. They are arranged for running in parallel and with the public electricity mains supply and are also controlled to operate as standby in the event of mains failure. To prevent radioactive contamination from the atmosphere, primary and secondary air filtration has been supplied for each engine. Other operational facilities and safeguards are mentioned and the cooling system described. (U.K.)

  16. Long term reliability analysis of standby diesel generators

    International Nuclear Information System (INIS)

    Winfield, D.J.

    1988-01-01

    The long term reliability of 11 diesel generators of 125 to 250 kV A size has been analysed from 26 years of data base information on individual diesel service as standby power supplies for the Chalk River research reactor facilities. Failure to start on demand and failure to run data is presented and failure by diesel subsystem and multiple failures are also analysed. A brief comparison is made with reliability studies of larger diesel generator units used for standby power service in nuclear power plants. (author)

  17. Time-independent and time-dependent contributions to the unavailability of standby safety system components

    International Nuclear Information System (INIS)

    Lofgren, E.V.; Uryasev, S.; Samanta, P.

    1997-01-01

    The unavailability of standby safety system components due to failures in nuclear power plants is considered to involve a time-independent and a time-dependent part. The former relates to the component's unavailability from demand stresses due to usage, and the latter represents the component's unavailability due to standby-time stresses related to the environment. In this paper, data from the nuclear plant reliability data system (NPRDS) were used to partition the component's unavailability into the contributions from standby-time stress (i.e., due to environmental factors) and demand stress (i.e., due to usage). Analyses are presented of motor-operated valves (MOVs), motor-driven pumps (MDPs), and turbine-driven pumps (TDPs). MOVs fail predominantly (approx. 78 %) from environmental factors (standby-time stress failures). MDPs fail slightly more frequently from demand stresses (approx. 63 %) than standby-time stresses, while TDPs fail predominantly from standby-time stresses (approx. 78 %). Such partitions of component unavailability have many uses in risk-informed and performance-based regulation relating to modifications to Technical Specification, in-service testing, precise determination of dominant accident sequences, and implementation of maintenance rules

  18. Are US utility standby rates inhibiting diffusion of customer-owned generating systems?

    International Nuclear Information System (INIS)

    Jackson, Jerry

    2007-01-01

    New, small-scale electric generation technologies permit utility customers to generate some of their own electric power and to utilize waste heat for space heating and other applications at the building site. This combined heat and power (CHP) characteristic can provide significant energy-cost savings. However, most current US utility regulations leave CHP standby rate specification largely to utility discretion resulting in claims by CHP advocates that excessive standby rates are significantly reducing CHP-related savings and inhibiting CHP diffusion. The impacts of standby rates on the adoption of CHP are difficult to determine; however, because of the characteristically slow nature of new technology diffusion. This study develops an agent-based microsimulation model of CHP technology choice using cellular automata to represent new technology information dispersion and knowledge acquisition. Applying the model as an n-factorial experiment quantifies the impacts of standby rates on CHP technologies under alternative diffusion paths. Analysis of a sample utility indicates that, regardless of the likely diffusion process, reducing standby rates to reflect the cost of serving a large number of small, spatially clustered CHP systems significantly increases the adoption of these technologies

  19. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  20. Cloud Standby: Disaster Recovery of Distributed Systems in the Cloud

    OpenAIRE

    Lenk , Alexander; Tai , Stefan

    2014-01-01

    International audience; Disaster recovery planning and securing business processes against outtakes have been essential parts of running a company for decades. As IT systems became more important, and especially since more and more revenue is generated over the Internet, securing the IT systems that support the business processes against outages is essential. Using fully operational standby sites with periodically updated standby systems is a well-known approach to prepare against disasters. ...

  1. The experiences of MDE stand-by; Les experiences de MDE stand-by

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The control of the electric power demand (MDE) is a worrying subject for many countries. The consumption of the electrical equipment in stand-by, is evaluated at 20 TWh/year for the ternary and residential sectors in Germany and 5,3 in France. Taking into account the SAVE project (Pilot campaign of municipal utilities for an improved rational use of energy), this study aims to observe the policies and the experiences of local governments in terms of energy consumption reduction. (A.L.B.)

  2. Is there any exposure from a mobile phone in stand-by mode?

    DEFF Research Database (Denmark)

    Mild, Kjell Hansson; Andersen, Jørgen Bach; Pedersen, Gert Frølund

    2012-01-01

    Several studies have been using a GSM mobile phone in stand-by mode as the source for exposure, and they claimed that this caused effects on for instance sleep and testicular function. In stand-by mode the phone is only active in periodic location updates, and this occurs with a frequency set by ...... by the net operator. Typical updates occur with 2-5 h in between, and between these updates the phone is to be considered as a passive radio receiver with no microwave emission. Thus, the exposure in stand-by mode can be considered negligible....

  3. Screening report : Municipality of Leamington : Leamington Pollution Control Centre stand-by emergency power class environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-03-15

    The Leamington Pollution Control Centre (PCC) is located in Ontario and treats residential and commercial wastewater collected from the Municipality of Leamington. The Leamington PCC currently has one standby diesel generator with a rated capacity of 545 kW. This generator provides power to the plant's disinfection facilities to reduce the risk of back-up into the collection system during power failures. The Municipality of Leamington plans to provide treatment in addition to disinfection during power outages. In order to achieve this, additional standby power is required to run the primary clarifiers, the aeration system and the secondary clarifiers. This document presented a screening report for the new standby generator, whose installation is considered a Schedule B under the Municipal Class Environmental Assessment process. The report reviewed background information on the proposed project; Ontario's Environmental Assessment Act; and the Class Environmental Assessment Act. It outlined the problem statement; identification of solutions; existing conditions; impacts and mitigation during construction and operation; and public consultation procedures. 2 refs., 4 figs., 1 appendix.

  4. Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Stack Characterization

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Kær, Søren Knudsen

    Fuel cells have started replacing traditional lead-acid battery banks in backup systems. Although these systems are characterized by long periods of standby, they must be able to start at any instant in the shortest time. In the case of low temperature proton exchange membrane fuel cell systems......, a precise estimation of hydration status of the fuel cell during standby is important for a fast and safe startup. In this article, the measurement of the complex impedance of the fuel cell is suggested as a method to estimate the membrane hydration status. A 56-cell fuel cell stack has been symmetrically...... fed with air whose temperature and relative humidity were controlled, and its complex impedance was measured at different frequencies and for different values of relative humidity. After showing that the experiment was repeatable, the fuel cell stack was characterized, a power regression model...

  5. Fuel oil systems for standby diesel-generators

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    This Standard provides the design requirements for fuel oil system for diesel-generators that provide standby power for a nuclear power generating station. The system includes all essential equipment from and including fuel oil storage tanks up to the terminal connection on the diesel-engine. It does not include that portion of the fuel oil system supplied by the diesel-generator manufacturer which is in accordance with Trial-Use Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations, IEEE-387-1972. This definition of scope is intended to exclude only those factory-assembled, engine-mounted appurtances supplied with a diesel-generator unit. Integral tanks are, however, within the scope of this Standard. It also excludes motors, motor control centers, switchgear, cables, and other electrical equipment which is used in operation of the fuel oil system, except to define interface requirements

  6. Low standby leakage 12T SRAM cell characterisation

    Science.gov (United States)

    Yadav, Arjun; Nakhate, Sangeeta

    2016-09-01

    In this work, a low power and variability-aware static random access memory (SRAM) architecture based on a twelve-transistor (12T) cell is proposed. This cell obtains low static power dissipation due to a parallel global latch (G-latch) and storage latch (S-latch), along with a global wordline (GWL), which offer a high cell ratio and pull-up ratio for reliable read and write operations and a low cell ratio and pull-up ratio during idle mode to reduce the standby power dissipation. In the idle state, only the S-latch stores bits, while the G-latch is isolated from the S-latch and the GWL is deactivated. The leakage power consumption of the proposed SRAM cell is thereby reduced by 38.7% compared to that of the conventional six-transistor (6T) SRAM cell. This paper evaluates the impact of the chip supply voltage and surrounding temperature variations on the standby leakage power and observes considerable improvement in the power dissipation. The read/write access delay, read static noise margin (SNM) and write SNM were evaluated, and the results were compared with those of the standard 6T SRAM cell. The proposed cell, when compared with the existing cell using the Monte Carlo method, shows an appreciable improvement in the standby power dissipation and layout area.

  7. 46 CFR Sec. 2 - Stand-by agreements.

    Science.gov (United States)

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION B-CONTROL AND UTILIZATION OF PORTS OPERATING CONTRACT Sec. 2 Stand-by agreements. The Director NSA, Maritime Administration, in advance of an emergency, may negotiate... 1901) under the control of the Maritime Administration and allocated for long term exclusive use by the...

  8. Impact of stand-by energy losses in electronic devices on smart network performance

    Directory of Open Access Journals (Sweden)

    Mandić-Lukić Jasmina S.

    2012-01-01

    Full Text Available Limited energy resources and environmental concerns due to ever increasing energy consumption, more and more emphasis is being put on energy savings. Smart networks are promoted worldwide as a powerful tool used to improve the energy efficiency through consumption management, as well as to enable the distributed power generation, primarily based on renewable energy sources, to be optimally explored. To make it possible for the smart networks to function, a large number of electronic devices is needed to operate or to be in their stand-by mode. The consumption of these devices is added to the consumption of many other electronic devices already in use in households and offices, thus giving rise to the overall power consumption and threatening to counteract the primary function of smart networks. This paper addresses the consumption of particular electronic devices, with an emphasis placed on their thermal losses when in stand-by mode and their total share in the overall power consumption in certain countries. The thermal losses of electronic devices in their stand-by mode are usually neglected, but it seems theoretically possible that a massive increase in their number can impact net performance of the future smart networks considerably so that above an optimum level of energy savings achieved by their penetration, total consumption begins to increase. Based on the current stand-by energy losses from the existing electronic devices, we propose that the future penetration of smart networks be optimized taking also into account losses from their own electronic devices, required to operate in stand-by mode.

  9. Optimal design of a maintainable cold-standby system

    Energy Technology Data Exchange (ETDEWEB)

    Yu Haiyang [Universite de technologie de Troyes, ISTIT, Rue Marie Curie, BP 2060, 10010 TROYES (France)]. E-mail: Haiyang.YU@utt.fr; Yalaoui, Farouk [Universite de technologie de Troyes, ISTIT, Rue Marie Curie, BP 2060, 10010 TROYES (France); Chatelet, Eric [Universite de technologie de Troyes, ISTIT, Rue Marie Curie, BP 2060, 10010 TROYES (France); Chu Chengbin [Universite de technologie de Troyes, ISTIT, Rue Marie Curie, BP 2060, 10010 TROYES (France); Management School, Hefei University of Technology, Hefei (China)

    2007-01-15

    This paper considers a framework to optimally design a maintainable cold-standby system. Not only the maintenance policy is to be determined, but also the reliability character of the components will be taken into account. Hence, the mean time to failure of the components and the policy time of good-as-new maintenances are proposed as decision variables. Following probability analyses, the system cost rate and the system availability are formulated as the optimization object and the constraint, respectively. Then, this optimization problem is directly resolved by recognizing its underlying properties. Moreover, the resolving procedure is found to be independent of the failure distributions of the components and the forms of the system cost, which is illustrated through a numerical example. As a conclusion, an exact method is successfully established to minimize the cost rate of a cold-standby system with the given maintenance facility.

  10. Optimal design of a maintainable cold-standby system

    International Nuclear Information System (INIS)

    Yu Haiyang; Yalaoui, Farouk; Chatelet, Eric; Chu Chengbin

    2007-01-01

    This paper considers a framework to optimally design a maintainable cold-standby system. Not only the maintenance policy is to be determined, but also the reliability character of the components will be taken into account. Hence, the mean time to failure of the components and the policy time of good-as-new maintenances are proposed as decision variables. Following probability analyses, the system cost rate and the system availability are formulated as the optimization object and the constraint, respectively. Then, this optimization problem is directly resolved by recognizing its underlying properties. Moreover, the resolving procedure is found to be independent of the failure distributions of the components and the forms of the system cost, which is illustrated through a numerical example. As a conclusion, an exact method is successfully established to minimize the cost rate of a cold-standby system with the given maintenance facility

  11. Stochastic behavior of a cold standby system with maximum repair time

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2015-09-01

    Full Text Available The main aim of the present paper is to analyze the stochastic behavior of a cold standby system with concept of preventive maintenance, priority and maximum repair time. For this purpose, a stochastic model is developed in which initially one unit is operative and other is kept as cold standby. There is a single server who visits the system immediately as and when required. The server takes the unit under preventive maintenance after a maximum operation time at normal mode if one standby unit is available for operation. If the repair of the failed unit is not possible up to a maximum repair time, failed unit is replaced by new one. The failure time, maximum operation time and maximum repair time distributions of the unit are considered as exponentially distributed while repair and maintenance time distributions are considered as arbitrary. All random variables are statistically independent and repairs are perfect. Various measures of system effectiveness are obtained by using the technique of semi-Markov process and RPT. To highlight the importance of the study numerical results are also obtained for MTSF, availability and profit function.

  12. Buoyancy driven flow in a hot water tank due to standby heat loss

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    Results of experimental and numerical investigations of thermal behavior in a vertical cylindrical hot water tank due to standby heat loss of the tank are presented. The effect of standby heat loss on temperature distribution in the tank is investigated experimentally on a slim 150l tank...... show that the CFD model predicts satisfactorily water temperatures at different levels of the tank during cooling by standby heat loss. It is elucidated how the downward buoyancy driven flow along the tank wall is established by the heat loss from the tank sides and how the natural convection flow...... with a height to diameter ratio of 5. A tank with uniform temperatures and with thermal stratification is studied. A detailed computational fluid dynamics (CFD) model of the tank is developed to calculate the natural convection flow in the tank. The distribution of the heat loss coefficient for the different...

  13. 12 CFR 614.4810 - Standby letters of credit.

    Science.gov (United States)

    2010-01-01

    ... party in the performance of an obligation. (b) As a matter of sound banking practice, banks for... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Standby letters of credit. 614.4810 Section 614.4810 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM LOAN POLICIES AND OPERATIONS Banks...

  14. Assessing the Economic and Environmental Prospects of Stand-By ...

    African Journals Online (AJOL)

    This paper presents an economic analysis of two stand-by power supply options for a typical Nigerian household namely diesel generator plant and solar powered systems. The analysis reveals that solar systems are the most economically viable. The environmental benefits associated with substituting diesel powered ...

  15. Air intake device for at least one stand-by aggregate installed in an emergency power supply building

    International Nuclear Information System (INIS)

    Stoll, A.; Schilling, R.

    1980-01-01

    Stand-by aggregates are installed in an energency power supply building in order to ensure the cooling of nuclear power plants during accidents. In order to assure the stand-by aggregates to be supplied with combustion air also in the case of fire, each stand-by aggregate is provided with two intake pipes for the combustion air, which are horizontally lead through the building wall on the opposite sides of the energency power supply building. Fire valves are incorporated in the inlet pipes, and one of them will always close in the case of fire. (orig.) [de

  16. Optimisation of the test policy of stand-by systems

    International Nuclear Information System (INIS)

    Signoret, J.P.; Muron, O.; Cohen, G.

    1980-09-01

    In a nuclear power plant there are several systems which are on stand-by position as, for instance, safety systems. These stand-by systems have to be ready to start as soon as any situation for which they have be designed occurs. A test policy is then necessary in order to know the state of such a system and repair the possible failures. The tests are normally performed at regular intervals of time according to a scheduled sequence. We have already shown during the 'IIIeme Congres National de Fiabilite' held in Perros-Guirec in 1976 how it is possible in this case to find the optimum test interval leading to the best mean availability of the system. It is, in fact, possible, to improve that by considering that if the test interval is fixed 'a priori' this does not allow to take into account information we have on the system state every time [fr

  17. Benefit Analysis of Emergency Standby System Promoted to Cogeneration System

    Directory of Open Access Journals (Sweden)

    Shyi-Wen Wang

    2016-07-01

    Full Text Available Benefit analysis of emergency standby system combined with absorption chiller promoted to cogeneration system is introduced. Economic evaluations of such upgraded projects play a major part in the decisions made by investors. Time-of-use rate structure, fuel cost and system constraints are taken into account in the evaluation. Therefore, the problem is formulated as a mixed-integer programming problem. Using two-stage methodology and modified mixed-integer programming technique, a novel algorithm is developed and introduced here to solve the nonlinear optimization problem. The net present value (NPV method is used to evaluate the annual benefits and years of payback for the cogeneration system. The results indicate that upgrading standby generators to cogeneration systems is profitable and should be encouraged, especially for those utilities with insufficient spinning reserves, and moreover, for those having difficulty constructing new power plants.

  18. Basis for Interim Operation for the K-Reactor in Cold Standby

    Energy Technology Data Exchange (ETDEWEB)

    Shedrow, B.

    1998-10-19

    The Basis for Interim Operation (BIO) document for K Reactor in Cold Standby and the L- and P-Reactor Disassembly Basins was prepared in accordance with the draft DOE standard for BIO preparation (dated October 26, 1993).

  19. Basis for Interim Operation for the K-Reactor in Cold Standby

    International Nuclear Information System (INIS)

    Shedrow, B.

    1998-01-01

    The Basis for Interim Operation (BIO) document for K Reactor in Cold Standby and the L- and P-Reactor Disassembly Basins was prepared in accordance with the draft DOE standard for BIO preparation (dated October 26, 1993)

  20. Allocation and sequencing in 1-out-of-N heterogeneous cold-standby systems: Multi-objective harmony search with dynamic parameters tuning

    International Nuclear Information System (INIS)

    Valaei, M.R.; Behnamian, J.

    2017-01-01

    A redundancy allocation is a famous problem in reliability sciences. A lot of researcher investigated about this problem, but a few of them focus on heterogeneous 1-out-of-N: G cold-standby redundancy in each subsystem. This paper considers a redundancy allocation problem (RAP) and standby element sequencing problem (SESP) for 1-out-of-N: G heterogeneous cold-standby system, simultaneously. Moreover, here, maximizing reliability of cold-standby allocation and minimizing cost of buying and time-independent elements are considered as two conflict objectives. This problem is NP-Hard and consequently, devizing a metaheuristic to solve this problem, especially for large-sized instances, is highly desirable. In this paper, we propose a multi-objective harmony search. Based on Taguchi experimental design, we, also, present a new parameters tuning method to improve the proposed algorithm. - Graphical abstract: Example of solution encoding. - Highlights: • This paper considers a redundancy allocation and standby element sequencing problem. • To solve this problem, a multi-objective harmony search algorithm is proposed. • Dynamic parameters tuning method is applied to improved the algorithm. • With this method, sensitivity of the algorithm to initial parameters is reduced.

  1. Technical and legal application possibilities of the compulsory labelling of the standby consumption of electrical household and office appliances - Project No. 53/03. Summary of the final report for the Federal Ministry of Economics and Labour

    Energy Technology Data Exchange (ETDEWEB)

    Schlomann, B.; Cremer, C.; Friedewald, M. [Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung, Karlsruhe (DE)] (and others)

    2005-06-13

    The standby consumption of electrical households and office appliances continues to be significant world-wide since the number of products with standby components is constantly increasing. For Germany, a recent assessment of the Fraunhofer ISI (Cremer et al. 2003) for 2001 arrived at an electricity demand of almost 15 TWh for household and office appliances in standby mode. i.e. in standby and off-mode. This represents almost 40% of the total consumption of these appliances and around 3% of the total electricity demand of the final energy sectors in Germany. The standby share in electricity demand is over 80 or even 90% for numerous appliances. The Federal Environmental Agency calculated that every year standby losses in German households and offices are responsible for wasted electricity amounting to 3.5 billion Euro (UBA 2004). For the OECD countries, field studies show that between 3 and 13% of the electricity consumption of households can be ascribed to standby losses (IEA 2001). Without energy policy measures on both national and international levels, there is a great risk that a further increase in standby consumption will occur. Many studies dealing with this subject have already been conducted and have shown that low standby consumption is technically feasible and usually achievable at a reasonable cost. One possible energy policy measure to reduce the standby consumption of electrical household and office appliances is the introduction of mandatory consumption labelling. In principle, a high degree of effectiveness is attributed to such regulatory/command-and-control measures with regard to influencing the energy efficiency of devices. Compulsory energy labels to identify and, where necessary, to classify electricity consumption produce greater market transparency and offer buyers an additional decision criterion. In this way they promote indirectly the development, production and supply of energy-efficient products. When combined with comparatively low

  2. Requirements under decree 430 UJD for unit outlet and standby power supply

    International Nuclear Information System (INIS)

    Vanco, K.

    2012-01-01

    At present, the nuclear power plants are only sufficient resources, which can cover a huge demand for electricity. Concentration so huge power in one place require adequate security from the perspective lead power outlet and standby power supply of reactor unit. (Author)

  3. Standby Gasoline Rationing Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-06-01

    The final rules adopted by the President for a Standby Gasoline Rationing Plan are presented. The plan provides that eligibility for ration allotments will be determined primarily on the basis of motor vehicle registrations, taking into account historical differences in the use of gasoline among states. The regulations also provide authority for supplemental allotments to firms so that their allotment will equal a specified percentage of gasoline use during a base period. Priority classifications, i.e., agriculture, defense, etc., are established to assure adequate gasoline supplies for designated essential services. Ration rights must be provided by end-users to their suppliers for each gallon sold. DOE will regulate the distribution of gasoline at the wholesale level according to the transfer by suppliers of redeemed ration rights and the gasoline allocation regulations. Ration rights are transferable. A ration banking system is created to facilitate transfers of ration rights. Each state will be provided with a reserve of ration rights to provide for hardship needs and to alleviate inequities. (DC)

  4. Standby Gasoline Rationing Plan. Contingency gasoline rationing regulations

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-01

    The Economic Regulatory Administration issues final rules with respect to standby gasoline rationing. The plan is designed for and would be used only in the event of a severe gasoline shortage. The plan provides that eligibility for ration allotments will be primarily on the basis of motor vehicle registrations. DOE will mail government ration checks to the parties named in a national vehicle registration file to be maintained by DOE. Ration recipients may cash these checks for ration coupons at various designated coupon issuance points. Retail outlets and other suppliers will be required to redeem the ration coupons received in exchange for gasoline sold. Supplemental gas will be given to high-priority activities. A ration banking system will be established with two separate and distinct of ration accounts: retail outlets and other suppliers will open redemption accounts for the deposit of redeemed ration rights; and individuals or firms may open ration rights accounts, which will operate in much the same manner as monetary checking accounts. A white market will be permitted for the sale of transfer of ration rights. A percentage of the total ration rights to be issued will be reserved for distribution to the states as a State Ration Reserve, to be used by the states primarily for the relief of hardship. A National Ration Reserave will also be established. All sections of the Standby Gasoline Rationing Regulations are analyzed. (MCW)

  5. The experiences of mastery of stand-by energy demand; Les experiences de MDE stand by

    Energy Technology Data Exchange (ETDEWEB)

    Schilken, P

    2001-07-01

    In the residential sector of the OECD countries, the electricity losses of domestic appliances in stand-by position represent 1.5% of the total electricity consumption. This study belongs to the SAVE project (pilot campaign of municipal utilities for an improved rational use of energy). Its aim is to observe the policies and experiments implemented by municipalities and municipal energy companies for the abatement of the electricity consumptions of stand-by origin. A working group consisting of the German Stadtwerke and some international partners have debated the possible actions and documents for an efficient information of the public. This document presents the brochures and local actions of this program. (J.S.)

  6. Crankshaft and component adequacy: Update of analysis and testing developed for nuclear standby engines

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    This book contains eight selections. Some of the topics are: reliability improvement of diesels in nuclear standby applications, diesel engine crankshaft torsional vibrations, pendulum dampers, transportation fatalities,and diesel component life predictions

  7. Reduction of standby energy use in set-top boxes in the United States and the European Union

    Energy Technology Data Exchange (ETDEWEB)

    Zandelin, S.

    2000-06-01

    In the US, there were over 110 million set-top boxes in 1999. About half of these boxes were game consoles. In the EU, the number of set-top boxes was estimated to be about 71 millions in 1999. The most common set-top boxes in the EU were analog satellite receivers. That is quite a difference from the US, where almost no analog satellite receivers exist. It is expected that the amount of set-top boxes will increase rapidly when the broadcasts switch to digital. Set-top boxes in the US consume 7.9 TWh of electricity every year. Of this 5.5 TWh, or 70 %, are consumed while in standby mode. The amount of energy used in standby in the US would be enough to heat about 220,000 Swedish houses. Even though almost half of the set-top boxes in the US are game consoles, they only use 30 % of the set-top energy. This is because they have low standby power. Since most analog cable boxes have a very high standby power, 46 % of the set-top energy come from analog cable boxes. Analog cable boxes use 76 % of the energy in standby mode. The set-top electricity consumption in the US is 0.70 % of the residential electricity use. In the EU the total amount of energy used by set-top boxes is 5.1 TWh every year. The fraction used in standby mode in the EU, 60 %, is smaller than in the US. In the EU, the most common boxes are the analog satellite receivers. They use 59 % of the total set-top energy, or 3.0 TWh. The set-top energy share of the residential electricity use in the EU is about 0.85 %. Sweden has a share that is less than half of the EU share. One reason for that could be that a lot of electricity is used for heating in Sweden. In most set-top boxes, high standby power is because most circuitry and components are still powered when they are not in use. By making modest redesigns and changes of communications protocols between the service provider and the user, the energy efficiency could be increased and the standby power consumption reduced significantly. If nothing is done to

  8. The African Standby Force and Regional Security Integration

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    the challenges facing the region? The regional enmities between the states seem to be widespread, deep-rooted and of a nearly chronic nature. In June 2015 the African Union and its member-states announced that they expected the five regionally based standby brigades to be fully operational by December 2015....... The readiness is to be tested at a continental field exercise, Amani Africa 11 to take place in South Africa October 2015. (Defence Web, 2015) The article will start by mapping out the security dynamics and architecture in East Africa, including its membership circles and priorities. The article...

  9. The advantages of reliability centered maintenance for standby safety systems

    International Nuclear Information System (INIS)

    Dam, R.F.; Ayazzudin, S.; Nickerson, J.H.; DeLong, A.I.

    2002-01-01

    predictive monitoring. The testing in this strategy is part of an effort to ensure that the desired function is not only available today, but will be available tomorrow as well. This paper considers the application of a streamlined form of RCM to the Emergency Core Cooling (ECC) and Standby Generator (SG) Systems of a CANDU plant. Recently completed studies provide useful insight into the important value added of the systematic assessment approach (using RCM techniques) for these standby safety systems. In the case of RCM analysis performed on the Emergency Core Cooling (ECC) System of Point Lepreau Nuclear Power Generating Station (PLGS), it was found that 60% of the current maintenance tasks are testing (functional, stroke, logic, and annunciation tests). Similarly, the SGs have 50% of the maintenance tasks associated with testing. The paper considers how the results of the RCM analysis demonstrate that the analysis can be used to assist in the optimization of the testing program dictated by reliability while also taking better advantage of the testing through condition monitoring and predictive maintenance techniques. Further, the results illustrate the importance of identifying and linking the different plant activities within a well integrated plant culture. (author)

  10. 31 CFR 585.518 - Certain standby letters of credit and performance bonds.

    Science.gov (United States)

    2010-07-01

    ... Certain standby letters of credit and performance bonds. (a) Notwithstanding any other provision of law... license authorizing the account party to establish a blocked account on its books in the name of the FRY... reimbursement that is required by applicable law. (c) Where there is outstanding a demand for payment under a...

  11. Human error considerations and annunciator effects in determining optimal test intervals for periodically inspected standby systems

    International Nuclear Information System (INIS)

    McWilliams, T.P.; Martz, H.F.

    1981-01-01

    This paper incorporates the effects of four types of human error in a model for determining the optimal time between periodic inspections which maximizes the steady state availability for standby safety systems. Such safety systems are characteristic of nuclear power plant operations. The system is modeled by means of an infinite state-space Markov chain. Purpose of the paper is to demonstrate techniques for computing steady-state availability A and the optimal periodic inspection interval tau* for the system. The model can be used to investigate the effects of human error probabilities on optimal availability, study the benefits of annunciating the standby-system, and to determine optimal inspection intervals. Several examples which are representative of nuclear power plant applications are presented

  12. Monitoring and controlling microbiological growth in a standby service water system

    International Nuclear Information System (INIS)

    Zisson, P.S.; Whitaker, J.M.; Neilson, H.L.; Mayne, L.L.

    1996-01-01

    In 1989, the US Nuclear Regulatory Commission formally recognized the potential for nuclear accidents caused by loss of heat transfer due to microbiological fouling and loss of system integrity caused by microbiologically influenced corrosion. To prevent such potential problems, monitoring, mitigation, and control procedures must be developed by all regulated plants. This article describes the control and mitigation strategy for the standby service water system of a boiling water reactor nuclear power plant

  13. Evaluation of Heliostat Standby Aiming Strategies to Reduce Avian Flux Hazards and Impacts on Operational Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wendelin, Timothy J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ho, Clifford K. [Sandia National Laboratories; Horstman, Luke [Sandia National Laboratories

    2017-06-03

    This paper presents a study of alternative heliostat standby aiming strategies and their impact on avian flux hazards and operational performance of a concentrating solar power plant. A mathematical model was developed that predicts the bird-feather temperature as a function of solar irradiance, thermal emittance, convection, and thermal properties of the feather. The irradiance distribution in the airspace above the Ivanpah Unit 2 heliostat field was simulated using a ray-trace model for two different times of the day, four days of the year, and nine different standby aiming strategies. The impact of the alternative aiming strategies on operational performance was assessed by comparing the heliostat slew times from standby position to the receiver for the different aiming strategies. Increased slew times increased a proxy start-up time that reduced the simulated annual energy production. Results showed that spreading the radial aim points around the receiver to a distance of ~150 m or greater reduced the hazardous exposure times that the feather temperature exceeded the hazard metric of 160 degrees C. The hazardous exposure times were reduced by ~23% and 90% at a radial spread of aim points extending to 150 m and 250 m, respectively, but the simulated annual energy production decreased as a result of increased slew times. Single point-focus aiming strategies were also evaluated, but these strategies increased the exposure hazard relative to other aiming strategies.

  14. Operating experience feedback report: Reliability of safety-related steam turbine-driven standby pumps. Commercial power reactors, Volume 10

    International Nuclear Information System (INIS)

    Boardman, J.R.

    1994-10-01

    This report documents a detailed analysis of failure initiators, causes and design features for steam turbine assemblies (turbines with their related components, such as governors and valves) which are used as drivers for standby pumps in the auxiliary feedwater systems of US commercial pressurized water reactor plants, and in the high pressure coolant injection and reactor core isolation cooling systems of US commercial boiling water reactor plants. These standby pumps provide a redundant source of water to remove reactor core heat as specified in individual plant safety analysis reports. The period of review for this report was from January 1974 through December 1990 for licensee event reports (LERS) and January 1985 through December 1990 for Nuclear Plant Reliability Data System (NPRDS) failure data. This study confirmed the continuing validity of conclusions of earlier studies by the US Nuclear Regulatory Commission and by the US nuclear industry that the most significant factors in failures of turbine-driven standby pumps have been the failures of the turbine-drivers and their controls. Inadequate maintenance and the use of inappropriate vendor technical information were identified as significant factors which caused recurring failures

  15. Loss optimizing low power 50 Hz transformers intended for AC/DC standby power supplies

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2004-01-01

    This paper presents the measured efficiency on selected low power conventional 50 Hz/230 V-AC transformers. The small transformers are intended for use in 1 W@5 V-DC series- or buck-regulated power supplies for standby purposes. The measured efficiency is compared for cheap off-the-self transformer...

  16. Seismic-safe conditions of blasting near pressure pipe-lines during power installation construction

    International Nuclear Information System (INIS)

    Smolij, N.I.; Nikitin, A.S.

    1980-01-01

    Seismic-safe conditions for performing drill-blasting operations in the vicinity of underground gas pipelines when constructing thermal- or nuclear power plants are discussed. It is shown that, for the determination of seismic-safe parameters, of drill-blasting operations, the maximum permissible level of seismic loads should be specified taking into account the mechanical properties of the pipeline.metal, structural parameters of the gas pipeline and the pressure of the medium transported. Besides, the seismic effect of the blast should be considered with regard to particular conditions of blasting and rock properties. The equations and diagrams used in the calculation are given

  17. Fiscal 1999 achievement report. Development of technology for reducing power consumption during standby (Research and development of technologies for application of standby power reduction to domestic and office-automation appliances); 1999 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden oyobi OA kiki no taiki denryoku sakugen jitsuyoka gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    Efforts are exerted to develop power-efficient modules to be built into electrical products for reduction in power consumption in the standby state for domestic and office-automation appliances. In this study, television sets, audio sets, and air conditioners were selected out of domestic appliances and, out of office-automation appliances, notebook-size and desktop personal computers were selected. The standby power consumption is to be reduced to 3mW for domestic appliances, to 0.2W for notebook-size personal computers, and to 1/10-1/200 of the level being currently consumed in the case of desktop personal computers. For domestic appliances, a power efficient module not insulated from the AC power line was developed, to be built into a CPU-aided appliance to be turned on and off by remote control for the reduction of its standby power to 3mW. For notebook-size personal computers, a power-efficient power source insulated from the AC power line was developed, which consumes but 0.2W of standby power. It was built into a marketed notebook-size personal computer and tested for performance. For desktop personal computers, a 25mW power source insulated from the AC power line was fabricated, and tested for performance. (NEDO)

  18. A Profile-Based Identification of Standby and Useless Electricity Consumption in Buildings

    OpenAIRE

    De Koster, Rien; Van Roy, Juan; Driesen, Johan

    2013-01-01

    Useless electricity consumption is the electricity consumption of an electric appliance or system that is not performing its primary function or that is performing its primary function without being useful. So, useless electricity consumption does not only consist of standby losses. To identify the useless electricity consumption in a building, a profile-based approach is developed. This approach is used to investigate the useless electricity consumption in five buildings of the University of...

  19. Comparative analysis of the machine repair Problem with imperfect coverage and service pressure condition

    Science.gov (United States)

    Wang, Kuo-Hsiung; Liou, Cheng-Dar; Lin, Yu-Hsueh

    2013-02-01

    We analyze the warm-standby M/M/R machine repair problem with multiple imperfect coverage which involving the service pressure condition. When an operating machine (or warm standby) fails, it may be immediately detected, located, and replaced with a coverage probability c by a standby if one is available. A recursive method is used to develop the steady-state analytic solutions. The total expected profit function per unit time is derived to determine the joint optimal values at the maximum profit. We utilize the direct search method to measure the various characteristics of the profit function followed by Quasi-Newton method to search the optimal solutions.

  20. An M[X]/G(a,b/1 Queueing System with Breakdown and Repair, Stand-By Server, Multiple Vacation and Control Policy on Request for Re-Service

    Directory of Open Access Journals (Sweden)

    G. Ayyappan

    2018-06-01

    Full Text Available In this paper, we discuss a non-Markovian batch arrival general bulk service single-server queueing system with server breakdown and repair, a stand-by server, multiple vacation and re-service. The main server’s regular service time, re-service time, vacation time and stand-by server’s service time are followed by general distributions and breakdown and repair times of the main server with exponential distributions. There is a stand-by server which is employed during the period in which the regular server remains under repair. The probability generating function of the queue size at an arbitrary time and some performance measures of the system are derived. Extensive numerical results are also illustrated.

  1. On a Batch Arrival Queuing System Equipped with a Stand-by Server during Vacation Periods or the Repairs Times of the Main Server

    Directory of Open Access Journals (Sweden)

    Rehab F. Khalaf

    2011-01-01

    Full Text Available We study a queuing system which is equipped with a stand-by server in addition to the main server. The stand-by server provides service to customers only during the period of absence of the main server when either the main server is on a vacation or it is in the state of repairs due to a sudden failure from time to time. The service times, vacation times, and repair times are assumed to follow general arbitrary distributions while the stand-by service times follow exponential distribution. Supplementary variables technique has been used to obtain steady state results in explicit and closed form in terms of the probability generating functions for the number of customers in the queue, the average number of customers, and the average waiting time in the queue while the MathCad software has been used to illustrate the numerical results in this work.

  2. Determination of reliability criteria for standby diesel generators at a nuclear power station

    International Nuclear Information System (INIS)

    Evans, M.G.K.

    1987-01-01

    The requirement for standby diesel generators at nuclear power stations is developed and a probabilistic approach used to define the reliability parameters. The present criteria used when ordering a diesel generator are compared with the testing required by the regulatory body and the most likely requirement following an accident. The impact of this on the diesels at a particular station and the root cause of failures are discussed. (orig.)

  3. Cold standby repairable system with working vacations and vacation interruption

    Institute of Scientific and Technical Information of China (English)

    Baoliang Liu; Lirong Cui; Yanqing Wen

    2015-01-01

    This paper studies a cold standby repairable system with working vacations and vacation interruption. The repairman’s multiple vacations policy, the working vacations policy and the vacation interruption are considered simultaneously. The lifetime of components fol ows a phase-type (PH) distribution. The repair time in the regular repair period and the working vacation period fol ow other two PH distributions at different rates. For this sys-tem, the vector-valued Markov process governing the system is constructed. We obtain several important performance measures for the system in transient and stationary regimes applying matrix-analytic methods. Final y, a numerical example is given to il ustrate the results obtained.

  4. Standby battery requirements for telecommunications power

    Energy Technology Data Exchange (ETDEWEB)

    May, G.J. [The Focus Partnership, 126 Main Street, Swithland, Loughborough, Leics LE12 8TJ (United Kingdom)

    2006-08-25

    The requirements for standby power for telecommunications are changing as the network moves from conventional systems to Internet Protocol (IP) telephony. These new systems require higher power levels closer to the user but the level of availability and reliability cannot be compromised if the network is to provide service in the event of a failure of the public utility. Many parts of these new networks are ac rather than dc powered with UPS systems for back-up power. These generally have lower levels of reliability than dc systems and the network needs to be designed such that overall reliability is not reduced through appropriate levels of redundancy. Mobile networks have different power requirements. Where there is a high density of nodes, continuity of service can be reasonably assured with short autonomy times. Furthermore, there is generally no requirement that these networks are the provider of last resort and therefore, specifications for continuity of power are directed towards revenue protection and overall reliability targets. As a result of these changes, battery requirements for reserve power are evolving. Shorter autonomy times are specified for parts of the network although a large part will continue to need support for hours rather minutes. Operational temperatures are increasing and battery solutions that provide longer life in extreme conditions are becoming important. Different battery technologies will be discussed in the context of these requirements. Conventional large flooded lead/acid cells both with pasted and tubular plates are used in larger central office applications but the majority of requirements are met with valve-regulated lead/acid (VRLA) batteries. The different types of VRLA battery will be described and their suitability for various applications outlined. New developments in battery construction and battery materials have improved both performance and reliability in recent years. Alternative technologies are also being proposed

  5. Reliability Electrical Power System of Hospital as Cold Standby System

    Directory of Open Access Journals (Sweden)

    Grabski Franciszek

    2016-07-01

    Full Text Available The probabilistic model of a hospital electrical power system consisting of mains, an emergency power system and the automatic transfer switch with the generator starter are discussed in this paper. The reliability model is semi-Markov process describing two different units renewable cold standby system and switch. The embedded Semi-Markov processes concept is applied for description of the system evolution. Time to failure of the system is represented by a random variable denoting the first passage time of the process from the given state to the subset of states. The appropriate theorems of the Semi-Markov processes theory allow us to evaluate the reliability function and some reliability characteristics.

  6. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  7. Probabilistic methodology for determining the optimum number of stand-by transformers in distribution substations; Metodologia probabilistica para determinacao do numero otimo de transformadores reservas em subestacoes de distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Joao Guilherme de C.; Silva, Armando M. Leite da [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Inst. de Sistemas Eletricos e Energia], Emails: costa@unifei.edu.br, armando@unifei.edu.br

    2009-07-01

    A new probabilistic methodology for determining the optimum number of stand-by transformers in distribution substations is presented. The calculus has three steps: reliability evaluation of a transformer system with a stand-by stock; calculus of investment and operation costs for different composition alternatives of stock; identification of the number of stand-by transformers, which minimizes the total cost. Concerning the the step 1, the operative states of the system are represented by a Markov process, where it is possible to calculate indicators as probability, frequency and average duration of failure, as well as to estimate average values of no-supplied energy and costs. The proposed methodology is applied to a 72 kV transformer system and the obtained results are discussed in details.

  8. Standby status report Hot Semiworks facility

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, C.R.

    1957-09-01

    This report is written to provide information concerning the status of the Hot Semiworks facility as it is placed in stand-by on July 1, 1957. The plant was constructed in 1951 and early 1952. It vas operated on Redox type investigations until the last of 1953. The plant was then converted to the Purex flowsheet under Project CA 513 D. Operations on the Purex type investigations were started in early 1955 and continued until early in 1956. At that time a maintenance program for plant improvement and repair was initiated. This program was completed on July 1, 1957. Statements are contained in this report which pertain to the present status of physical equipment and facilities and the adequacy, operating experience, recommendations for improvement, previous work, and future considerations of the plant. However, the primary intent of the report is to provide pertinent information to personnel associated with a future start-up. For this reason, certain parts of the report are quite detailed. Only statements concerning the existing or previous state of the facility and equipment are factual. Others are opinions or experiences of plant operating personnel. Emphasis has also been placed on the faults encountered rather than the good features of the plant, in order that these faults might be corrected in the future.

  9. Earthquake stand-by instruction device for nuclear power plant

    International Nuclear Information System (INIS)

    Nakagawa, Masaki; Ijima, Tadashi

    1998-01-01

    The magnitude of earthquakes is forecast at a high accuracy by disposing seismic detectors to a plurality of points distant from an object plant. The accuracy of the judgement for the magnitude of earthquakes can be improved by processing seismic movements by using seismic movements observed along with elapse of time. The measured seismic waveforms are always stored even during the processing time. With such procedures, when one processing is completed, processing can be conducted successively by using stored data, by which processing can be conducted by using all the data from the occurrence of the earthquakes. Then, the seismic movements can be estimated from an early stage of the occurrence of the earthquakes, and since the seismic movement can be judged based on a great amount of data with lapse of time, an appropriate stand-by instruction can be provided. (N.H.)

  10. FY 2000 report on the results of the development of the stand-by consumption power reduction technology. Verification experiment on the technology to reduce stand-by power of household electric appliances; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden seihin taikiji denryoku sakugen gijutsu no jissho jikken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Study was made of the energy conservation by reducing stand-by consumption power of household electric appliances. In the study, remote control, household electric appliance, and outlet box were developed, and a system was developed in which each of the three was connected by network and the commercial power source supply is cut off at the time of the stand-by state of household electric appliances. The outlet box collectively manages timer information and reservation information. User sends out control command toward the outlet box using the two-way remote control, and controls all the household electric appliances connected via network. The screen data of household electric appliances are sent to the two-way remote control via the outlet box and presented to user. When the time comes for automatic execution such as video recording during absence, the outlet box carries commercial power source to household electric appliances. Using these appliances, verification experiment was carried out in the model house which was built with the ordinary house as model. A reduction in stand-by consumption power, approximately 218kWh/year(center dot)household, was verified. (NEDO)

  11. Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Tommy Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Philbert Roland [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garcia, Samuel Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-09

    During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

  12. How to design your stand-by diesel generator unit for maximum reliability

    International Nuclear Information System (INIS)

    Kauffmann, W.M.

    1979-01-01

    Critical stand-by power applications, such as in a nuclear plant, or radio support stations, demand exacting guidelines for positive start, rapid acceleration, load acceptance with minimum voltage drop, and quick recovery to rated voltage. The design of medium-speed turbocharged and intercooled diesel-engine-generator for this purpose is considered. Selection of the diesel engine, size, and number of units, from the standpoint of cost, favors minimum number of units with maximum horsepower capability. Four-cycle diesels are available in 16 to 20 cyinders V-configurations, with 200 BMEP (brake mean-effective pressure) continuous and 250 BMEP peaking

  13. Optimal test intervals of standby components based on actual plant-specific data

    International Nuclear Information System (INIS)

    Jones, R.B.; Bickel, J.H.

    1987-01-01

    Based on standard reliability analysis techniques, both under testing and over testing affect the availability of standby components. If tests are performed too often, unavailability is increased since the equipment is being used excessively. Conversely if testing is performed too infrequently, the likelihood of component unavailability is also increased due to the formation of rust, heat or radiation damage, dirt infiltration, etc. Thus from a physical perspective, an optimal test interval should exist which minimizes unavailability. This paper illustrates the application of an unavailability model that calculates optimal testing intervals for components with a failure database. (orig./HSCH)

  14. Considerations on Fail Safe Design for Design Basis Accident (DBA) vs. Design Extension Condition (DEC): Lesson Learnt from the Fukushima Accident

    International Nuclear Information System (INIS)

    Ha, Jun Su; Kim, Sungyeop

    2014-01-01

    The fail safety design is referred to as an inherently safe design concept where the failure of an SSC (System, Structure or Component) leads directly to a safe condition. Usually the fail safe design has been devised based on the design basis accident (DBAs), because the nuclear safety has been assured by securing the capability to safely cope with DBAs. Currently regards have been paid to the DEC (Design Extension Condition) as an extended design consideration. Hence additional attention should be paid to the concept of the fail safe design in order to consider the DEC, accordingly. In this study, a case chosen from the Fukushima accident is studied to discuss the issue associated with the fail safe design in terms of DBA and DEC standpoints. For the fail safe design to be based both on the DBA and the DEC, a Mode Changeable Fail Safe Design (MCFSD) is proposed in this study. Additional discussions on what is needed for the MCFSD to be applied in the nuclear safety are addressed as well. One of the lessons learnt from the Fukushima accident should include considerations on the fail-safe design in a changing regulatory framework. Currently the design extension condition (DEC) including severe accidents should be considered during designing and licensing NPPs. Hence concepts on the fail safe design need to be changed to be based on not only the DBA but also the DEC. In this study, a case on a fail-safe design chosen from the Fukushima accident is studied to discuss the issue associated with the fail safe design in terms of DBA and DEC conditions. For the fail safe design to be based both on the DBA and the DEC, a Mode Changeable Fail Safe Design (MCFSD) is proposed in this study. Additional discussions on what is needed for the MCFSD to be applied in the nuclear safety are addressed as well

  15. Radioactive gas standby treatment apparatus with high efficiency rechargeable charcoal filter

    International Nuclear Information System (INIS)

    Hickey, T.N.; Spulgis, I.S.

    1975-01-01

    Described is a standby gas treatment system for removal of radioactive release from a nuclear containment structure not only during normal purge operations but also in the event of a design basis accident. Ventiduct trains arranged in parallel so that one is redundant are each operative to extract dust in excess of 0.3 microns and adsorb radioactive iodine and compounds thereof at 99.9 percent plus efficiency. A rechargeable gasketless charcoal filter in each train can be filled or emptied without removing the filter enclosures per se. Laminar flow filter beds entirely encapsulate the gas stream to provide low gas velocity and even distribution across the charcoal cage without channeling, thereby securing long residence time

  16. Reliability estimation of a N- M-cold-standby redundancy system in a multicomponent stress-strength model with generalized half-logistic distribution

    Science.gov (United States)

    Liu, Yiming; Shi, Yimin; Bai, Xuchao; Zhan, Pei

    2018-01-01

    In this paper, we study the estimation for the reliability of a multicomponent system, named N- M-cold-standby redundancy system, based on progressive Type-II censoring sample. In the system, there are N subsystems consisting of M statistically independent distributed strength components, and only one of these subsystems works under the impact of stresses at a time and the others remain as standbys. Whenever the working subsystem fails, one from the standbys takes its place. The system fails when the entire subsystems fail. It is supposed that the underlying distributions of random strength and stress both belong to the generalized half-logistic distribution with different shape parameter. The reliability of the system is estimated by using both classical and Bayesian statistical inference. Uniformly minimum variance unbiased estimator and maximum likelihood estimator for the reliability of the system are derived. Under squared error loss function, the exact expression of the Bayes estimator for the reliability of the system is developed by using the Gauss hypergeometric function. The asymptotic confidence interval and corresponding coverage probabilities are derived based on both the Fisher and the observed information matrices. The approximate highest probability density credible interval is constructed by using Monte Carlo method. Monte Carlo simulations are performed to compare the performances of the proposed reliability estimators. A real data set is also analyzed for an illustration of the findings.

  17. Evaluation of transient natural circulation behavior during accident in low power/shutdown condition of YGN units 3/4

    International Nuclear Information System (INIS)

    Bang, Young Seok; Kim, Kap; Seul, Kwang Won; Kim, Hho Jung

    1997-01-01

    A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation

  18. Technical and legal application possibilities of the compulsory labelling of the standby consumption of electrical household and office appliances - Project No. 53/03. Final report for the Federal Ministry of Economics and Labour; Technische und rechtliche Anwendungsmoeglichkeiten einer verpflichtenden Kennzeichnung des Leerlaufverbrauchs strombetriebener Haushalts- und Buerogeraete - Dienstleistungsvorhaben Nr. 53/03. Abschlussbericht an das Bundesministerium fuer Wirtschaft und Arbeit

    Energy Technology Data Exchange (ETDEWEB)

    Schlomann, B.; Cremer, C.; Friedewald, M. [Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung, Karlsruhe (DE)] (and others)

    2005-04-27

    The standby consumption of electrical households and office appliances continues to be significant world-wide since the number of products with standby componen ts is constantly increasing. For Germany, a recent assessment of the Fraunhofer ISI (Cremer et al. 2003) for 2001 arrived at an electricity demand of almost 15 TWh for household and office appliances in standby mode. i.e. in standby and off -mode. This represents almost 40% of the total consumption of these appliances and around 3% of the total electricity demand of the final energy sectors in Ge rmany. The standby share in electricity demand is over 80 or even 90% for numer ous appliances. The Federal Environmental Agency calculated that every year stan dby losses in German households and offices are responsible for wasted electrici ty amounting to 3.5 billion Euro (UBA 2004). For the OECD countries, field studi es show that between 3 and 13% of the electricity consumption of households can be ascribed to standby losses (IEA 2001). Without energy policy measures on bot h national and international levels, there is a great risk that a further increa se in standby consumption will occur. Many studies dealing with this subject hav e already been conducted and have shown that low standby consumption is technica lly feasible and usually achievable at a reasonable cost. One possible energy po licy measure to reduce the standby consumption of electrical household and offic e appliances is the introduction of mandatory consumption labelling. In principl e, a high degree of effectiveness is attributed to such regulatory/command-and-c ontrol measures with regard to influencing the energy efficiency of devices. Com pulsory energy labels to identify and, where necessary, to classify electricity consumption produce greater market transparency and offer buyers an additional d ecision criterion. In this way they promote indirectly the development, producti on and supply of energy-efficient products. When combined with

  19. Radioactive gas standby treatment apparatus with high efficiency rechargeable charcoal filter

    International Nuclear Information System (INIS)

    Hickey, T.N.; Spulgis, I.S.

    1976-01-01

    A description is given of a standby gas treatment system for removal of radioactive release from a nuclear containment structure not only during normal purge operations but also in the event of a design basis accident. Ventiduct trains arranged in parallel so that one is redundant are each operative to extract dust in excess of 0.3 microns and adsorb radioactive iodine and compounds thereof at 99.9 percent plus efficiency. A rechargeable gasketless charcoal filter in each train can be filled or emptied without removing the filter enclosures per se. Laminar flow filter beds entirely encapsulate the gas stream to provide low gas velocity and even distribution across the charcoal cage without channeling, thereby securing long residence time. 2 claims, 9 drawing figures

  20. Translation initiation in bacterial polysomes through ribosome loading on a standby site on a highly translated mRNA

    Science.gov (United States)

    Andreeva, Irena

    2018-01-01

    During translation, consecutive ribosomes load on an mRNA and form a polysome. The first ribosome binds to a single-stranded mRNA region and moves toward the start codon, unwinding potential mRNA structures on the way. In contrast, the following ribosomes can dock at the start codon only when the first ribosome has vacated the initiation site. Here we show that loading of the second ribosome on a natural 38-nt-long 5′ untranslated region of lpp mRNA, which codes for the outer membrane lipoprotein from Escherichia coli, takes place before the leading ribosome has moved away from the start codon. The rapid formation of this standby complex depends on the presence of ribosomal proteins S1/S2 in the leading ribosome. The early recruitment of the second ribosome to the standby site before translation by the leading ribosome and the tight coupling between translation elongation by the first ribosome and the accommodation of the second ribosome can contribute to high translational efficiency of the lpp mRNA. PMID:29632209

  1. Experiences from maintaining the reliability of a nuclear standby diesel generator system

    International Nuclear Information System (INIS)

    Tammi, P.

    1982-01-01

    The nuclear standby diesel generator system is quite complicated comprising several mechanical and electrotechnical components, on which the reliability of the system is depending. It is an important support system of the plant safety system, and like the safety system it is composed of separate redundant units. The Loviisa nuclear power station has eight diesel generators. The first four of them were taken into operation in 1976. When the frequency of some mechanical failures showed increase, a project was started at the end of 1980 with the intention to find out potential failure possibilities and means for prevention of failures. The work has been mainly concentrated on improving the reliability of the diesel engines. (Auth.)

  2. Optimizing efficiency on conventional transformer based low power AC/DC standby power supplies

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2004-01-01

    This article describes the research results for simple and cheap methods to reduce the idle- and load-losses in very low power conventional transformer based power supplies intended for standby usage. In this case "very low power" means 50 Hz/230 V-AC to 5 V-DC@1 W. The efficiency is measured...... on two common power supply topologies designed for this power level. The two described topologies uses either a series (or linear) or a buck regulation approach. Common to the test power supplies is they either are using a standard cheap off-the-shelf transformer, or one, which are loss optimized by very...

  3. CFD predictions of standby liquid control system mixing in lower plenum of a BWR

    International Nuclear Information System (INIS)

    Boyd, Christopher; Skarda, Raymond

    2014-01-01

    Highlights: • Computational fluid dynamics analysis of BWR lower plenum. • Mixing and stratification of the standby liquid control system injection. • Scoping study highlights the expected flow paths and limitations of experiments. - Abstract: During an anticipated transient without scram (ATWS) scenario in certain boiling water reactor (BWR) systems, a standby liquid control system (SLCS) is used to inject a sodium pentaborate solution into the reactor system in order to quickly shut down (scram) the reactor without the use of the control rods. Some BWR designs utilize a SLCS that injects through a set of nozzles on a vertical pipe in the peripheral region of the lower plenum of the reactor vessel. During the scenario, system water levels are reduced and natural circulation flow rates down through the jet pump nozzles and up into the core are a small fraction of the rated system flow. It is during this period that the SLCS flows are considered. This work outlines some initial scoping studies completed by the staff at the Nuclear Regulatory Commission (NRC). An attempt at benchmarking the computational fluid dynamics (CFD) approach using a set of available test data from a small facility is outlined. Due to our lack of information related to specific details of the facility geometry along with the limited data available from the test, the benchmark exercise produced only a qualitative basis for selecting turbulence models and mesh density. A CFD model simulating a full-scale reactor system is developed for the lower plenum of a representative BWR/4 design and SLCS flows and mixing are studied under a range of flow conditions. The full-scale BWR simulation builds upon the lessons learned from the benchmark exercise. One challenge for this work is the large size of the domain and the relatively small size of the geometric details such as flow passages and gaps. The geometry is simplified to make meshing feasible by eliminating some of the small features. The

  4. Project Management Plan to Maintain Safe and Compliant Conditions at the Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    COX, G.J.

    1999-01-01

    This Project Management Plan presents the overall plan, description, mission, and workscope for the Plutonium Finishing Plant (PFP) maintain safe and compliant conditions project at PFP. This plan presents the overall description, mission, work scope, and planning for the Plutonium Finishing Plant (PFP) Maintain Safe and Compliant Conditions Project at PFP. This project includes all tasks required to maintain the safety boundary for the PFP Complex, except for the 2736-2 Vault Complex and the 234-52 vaults and vault-type rooms. The intent of this plan is to describe how this project will be managed and integrated with the stabilization, and deactivation activities. This plan supplements the overall integrated plan presented in the Plutonium Finishing Plant Integrated Project Management Plan (IPMP), HNF-3617, Rev. 0. This is the top-level definitive project management document that specifies the technical (work scope), schedule, and cost baselines that will manage the execution of this project. It describes the organizational approach and roles/responsibilities implemented to execute the project. This plan is under configuration management and any deviations must be authorized by appropriate change control action

  5. Impact of one's own mobile phone in stand-by mode on personal radiofrequency electromagnetic field exposure.

    Science.gov (United States)

    Urbinello, Damiano; Röösli, Martin

    2013-01-01

    When moving around, mobile phones in stand-by mode periodically send data about their positions. The aim of this paper is to evaluate how personal radiofrequency electromagnetic field (RF-EMF) measurements are affected by such location updates. Exposure from a mobile phone handset (uplink) was measured during commuting by using a randomized cross-over study with three different scenarios: disabled mobile phone (reference), an activated dual-band phone and a quad-band phone. In the reference scenario, uplink exposure was highest during train rides (1.19 mW/m(2)) and lowest during car rides in rural areas (0.001 mW/m(2)). In public transports, the impact of one's own mobile phone on personal RF-EMF measurements was not observable because of high background uplink radiation from other people's mobile phone. In a car, uplink exposure with an activated phone was orders of magnitude higher compared with the reference scenario. This study demonstrates that personal RF-EMF exposure is affected by one's own mobile phone in stand-by mode because of its regular location update. Further dosimetric studies should quantify the contribution of location updates to the total RF-EMF exposure in order to clarify whether the duration of mobile phone use, the most common exposure surrogate in the epidemiological RF-EMF research, is actually an adequate exposure proxy.

  6. Fiscal year 1999 multi-year work plan, advanced reactors transition program

    International Nuclear Information System (INIS)

    Gantt, D.A.

    1998-01-01

    The Advanced Reactors Transition (ART) has two missions. One, funded by DOE-EM is to transition assigned, surplus facilities to a safe and compliant, low-cost stable, deactivated condition (requiring minimal surveillance and maintenance) pending eventual reuse or D and D. Facilities to be transitioned include the 309 Building/Plutonium Recycle Test Reactor (PRTR) and Nuclear Energy (NE) Legacy Facilities. The second mission, funded by DOE-NE, is to maintain the Fast Flux Test Facility (FFTF) and affiliated 400 Area buildings in a safe and compliant standby condition. The condition of the plant hardware, software and personnel is to be preserved in a manner not to preclude a plant restart

  7. Fiscal year 1999 multi-year work plan, advanced reactors transition program

    Energy Technology Data Exchange (ETDEWEB)

    Gantt, D.A.

    1998-09-17

    The Advanced Reactors Transition (ART) has two missions. One, funded by DOE-EM is to transition assigned, surplus facilities to a safe and compliant, low-cost stable, deactivated condition (requiring minimal surveillance and maintenance) pending eventual reuse or D and D. Facilities to be transitioned include the 309 Building/Plutonium Recycle Test Reactor (PRTR) and Nuclear Energy (NE) Legacy Facilities. The second mission, funded by DOE-NE, is to maintain the Fast Flux Test Facility (FFTF) and affiliated 400 Area buildings in a safe and compliant standby condition. The condition of the plant hardware, software and personnel is to be preserved in a manner not to preclude a plant restart.

  8. The pool of preactivated Lck in the initiation of T-cell signaling: a critical re-evaluation of the Lck standby model

    Czech Academy of Sciences Publication Activity Database

    Ballek, Ondřej; Valečka, Jan; Manning, Jasper; Filipp, Dominik

    2014-01-01

    Roč. 93, spring (2014), s. 384-395 ISSN 0818-9641 R&D Projects: GA ČR GA310/09/2084 Institutional support: RVO:68378050 Keywords : Lck standby model * Lck kinase * TCR triggering * kinetic-segregation model * CD45-deficient T- cell Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.147, year: 2014

  9. The pool of preactivated Lck in the initiation of T-cell signaling: a critical re-evaluation of the Lck standby model

    Czech Academy of Sciences Publication Activity Database

    Ballek, Ondřej; Valečka, Jan; Manning, Jasper; Filipp, Dominik

    2014-01-01

    Roč. 93, spring (2014), s. 384-395 ISSN 0818-9641 R&D Projects: GA ČR GA310/09/2084 Institutional support: RVO:68378050 Keywords : Lck standby model * Lck kinase * TCR triggering * kinetic-segregation model * CD45-deficient T-cell Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.147, year: 2014

  10. A selection of problems related to safe working conditions in nuclear power plants

    International Nuclear Information System (INIS)

    Brunner, K.H.

    1984-01-01

    Two representative examples were chosen to demonstrate that the problems related to safe working conditions can be solved with work being prepared extensively and in detail taking into consideration radiation protection and conventional job safety measures and with qualified staff. Most of the job safety problems in nuclear power plants are pretty much the same as in conventional plants. Despite successful implementation of employment and radiation protection in nuclear power plants, improvements in detail are possible and make sense. (orig.) [de

  11. The Implementation of the Responsibility to Protect (R2P) Norms by the African Standby Force in Sub-Saharan Africa

    Science.gov (United States)

    2017-06-09

    Security Council to intervene in situations where genocide, war crimes, and crimes against humanity are occurring to protect civilians. In this regard...Republic of the Congo PSC Peace and Security Council R2P Responsibility to Protect REC Regional Economic Communities SADC Southern Africa...Development Community SADCBRIG Southern Africa Development Community Standby Brigade UN United Nations UNSC United Nations Security Council x

  12. The safe home project.

    Science.gov (United States)

    Arphorn, Sara; Jiraniratisai, Sopaphan; Rungtakul, Rungsri; Phutta, Nikom

    2011-12-01

    The Thai Health Promotion Foundation supported the Improvement of Quality of Life of Informal Workers project in Ban Luang District, Amphur Photaram, Ratchaburi Province. There were many informal workers in Ban Luang District. Sweet-crispy fish producers in Ban Luang were the largest group among the sweet-crispy fish producers in Thailand. This project was aimed at improving living and working conditions of informal workers, with a focus on the sweet-crispy fish group. Good practices of improved living and working conditions were used to help informal workers build safe, healthy and productive work environments. These informal workers often worked in substandard conditions and were exposed to various hazards in the working area. These hazards included risk of exposure to hot work environment, ergonomics-related injuries, chemical hazards, electrical hazards etc. Ergonomics problems were commonly in the sweet-crispy fish group. Unnatural postures such as prolonged sitting were performed dominantly. One hundred and fifty informal workers participated in this project. Occupational health volunteers were selected to encourage occupational health and safety in four groups of informal workers in 2009. The occupational health volunteers trained in 2008 were farmers, beauty salon workers and doll makers. The occupational health and safety knowledge is extended to a new informal worker group: sweet-crispy fish producer, in 2009. The occupational health and safety training for sweet-crispy fish group is conducted by occupational health volunteers. The occupational health volunteers increased their skills and knowledge assist in to make safe home and safe community through participatory oriented training. The improvement of living and working condition is conducted by using a modified WISH, Work Improvement for Safe Home, checklist. The plans of improvement were recorded. The informal workers showed improvement mostly on material handling and storage. The safe uses and safe

  13. High-ratio voltage conversion in CMOS for efficient mains-connected standby

    CERN Document Server

    Meyvaert, Hans

    2016-01-01

    This book describes synergetic innovation opportunities offered by combining the field of power conversion with the field of integrated circuit (IC) design. The authors demonstrate how integrating circuits enables increased operation frequency, which can be exploited in power converters to reduce drastically the size of the discrete passive components. The authors introduce multiple power converter circuits, which are very compact as result of their high level of integration. First, the limits of high-power-density low-voltage monolithic switched-capacitor DC-DC conversion are investigated to enable on-chip power granularization. AC-DC conversion from the mains to a low voltage DC is discussed, enabling an efficient and compact, lower-power auxiliary power supply to take over the power delivery during the standby mode of mains-connected appliances, allowing the main power converter of these devices to be shut down fully. Discusses high-power-density monolithic switched-capacitor DC-DC conversion in bulk CMOS,...

  14. Implementing low power consumption in standby mode in the case of power supplies with power factor correction

    OpenAIRE

    Martín, Kevin; F., Pablo; G., Diego; Sebastián, Javier; Álvarez, Santiago

    2017-01-01

    This work analyzes different options to implement low power consumption in Switching Mode Power Supplies (SMPSs) with Power Factor Correction (PFC) when they are in standby mode. The standard SMPSs for power levels higher than 100 W are made up of two stages: a classical PFC stage based on a Boost Converter operating in the Continuous Conduction Mode and a second stage based on any type of isolated DC-DC converter. The value of the resistive sensors needed by the PFC control stage determines ...

  15. Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Variable Temperature Stack Characterization

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Kær, Søren Knudsen

    2013-01-01

    Fuel cells are getting growing interest in both backup systems and electric vehicles. Although these systems are characterized by periods of standby, they must be able to start at any instant in the shortest possible time. However, the membranes of which proton exchange membrane fuel cells are made...

  16. Visiting Black Patients: Racial Disparities in Security Standby Requests.

    Science.gov (United States)

    Green, Carmen R; McCullough, Wayne R; Hawley, Jamie D

    2018-02-01

    Structural inequalities exist within healthcare. Racial disparities in hospital security standby requests (SSRs) have not been previously explored. We speculated hospital SSRs varied based upon race with black patients and their visitors negatively impacted. An 8-year retrospective study of hospital security dispatch information was performed. Data were analyzed to determine demographic information, and service location patterns for SSRs involving patients and their visitors. The race of the patient's visitors was imputed using the patient's race. The observed and expected (using hospital census data) number of patients impacted by SSRs was compared. Descriptive statistics were computed. Categorical data were analyzed using chi-square or Fisher exact test statistic. A p patients who were white (N = 642; 63%), female (56%), or patient's race. Although Black patients represent 12% of the hospital population, they and their visitors were more than twice as likely (p patients (N = 106; 10%) combined (p patients and their visitors. It also introduces the concept of "security intervention errors in healthcare environments." New metrics and continuous quality improvement initiatives are needed to understand and eliminate racial/ethnic based disparities in SSRs. Copyright © 2018 National Medical Association. Published by Elsevier Inc. All rights reserved.

  17. Aging assessment of the boiling-water reactor (BWR) standby liquid control system

    International Nuclear Information System (INIS)

    Orton, R.D.; Johnson, A.B.; Buckley, G.D.; Larson, L.L.

    1992-10-01

    Pacific Northwest Laboratory conducted a Phase I aging assessment of the standby liquid control (SLC) system used in boiling-water reactors. The study was based on detailed reviews of SLC system component and operating experience information obtained from the Nuclear Plant Reliability Database System, the Nuclear Document System, Licensee Event Reports, and other databases. Sources dealing with sodium pentaborate, borates, boric acid, and the effects of environment and corrosion in the SLC system were reviewed to characterize chemical properties and corrosion characteristics of borated solutions. The leading aging degradation concern to date appears to be setpoint drift in relief valves, which has been discovered during routine surveillance and is thought to be caused by mechanical wear. Degradation was also observed in pump seals and internal valves. In general, however, the results of the Phase I study suggest that age-related degradation of SLC systems has not been serious

  18. CAREM-25: Residual heat removal system

    International Nuclear Information System (INIS)

    Arvia, Roberto P.; Coppari, Norberto R.; Gomez de Soler, Susana M.; Ramilo, Lucia B.

    2000-01-01

    The objective of this work was the definition and consolidation of the residual heat removal system for the CAREM 25 reactor. The function of this system is cool down the primary circuit, removing the core decay heat from hot stand-by to cold shutdown and during refueling. In addition, this system heats the primary water from the cold shutdown condition to hot stand-by condition during the reactor start up previous to criticality. The system has been designed according to the requirements of the standards: ANSI/ANS 51.1 'Nuclear safety criteria for the design of stationary PWR plants'; ANSI/ANS 58.11 'Design criteria for safe shutdown following selected design basis events in light water reactors' and ANSI/ANS 58.9 'Single failure criteria for light water reactor safety-related fluid systems'. The suggested design fulfills the required functions and design criteria standards. (author)

  19. Towards Safe Robotic Surgical Systems

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Wisniewski, Rafael

    2015-01-01

    a controller for motion compensation in beating-heart surgery, and prove that it is safe, i.e., the surgical tool is kept within an allowable distance and orientation of the heart. We solve the problem by simultaneously finding a control law and a barrier function. The motion compensation system is simulated...... from several initial conditions to demonstrate that the designed control system is safe for every admissible initial condition....

  20. Proposed standby gasoline rationing plan. Economic and regulatory analysis draft

    Energy Technology Data Exchange (ETDEWEB)

    1978-06-01

    This economic and regulatory analysis meets the requirements of the Energy Policy and Conservation Act, which calls for an evaluation of the potential economic impacts of the gasoline rationing contingency plan. In addition, this analysis is intended to satisfy the requirements of the President's Executive Order No. 12044 of March 23, 1978, regarding government regulations, and provides an inflationary impact statement for the proposed rationing plan. To perform the analysis of rationing program impacts on the total national economy, three separate projections were required. First, a projection is made of the ''normal'' U.S. economy for a future period--the last quarter of 1980 through the third quarter of 1981 in this analysis. Second, a projection is made of the impacts which a petroleum supply interruption would have on the U.S. economy during this future period, assuming that DOE's standby allocation and price control regulations were implemented for crude oil and products. Third, and most significant, an estimate is made of the incremental impacts of the gasoline rationing program on this already-perturbed future U.S. economy.

  1. An Energy-Saving Concept of the Smart Building Power Grid with Separated Lines for Standby Devices

    Directory of Open Access Journals (Sweden)

    Dmytro Zubov

    2016-09-01

    Full Text Available Standby power takes 5-10 % of the residential electricity around the world. Some countries lose more than 14 % of the total electricity used in the residential sector. Hence, a new energysaving concept that could help to decrease the power losses is discussed in this paper. Firstly, the two power lines of infrastructure for continuously connected equipment and for standby devices is proposed for new smart buildings. Secondly, the segmented infrastructure with unified hardwareunits is proposed for existing smart buildings (the new one can apply this principle as well. The contactors (i.e. unified hardware units consist of the NodeMcu Lua ESP8266 WiFi IoTdevelopment board, ACS712T ELC-30A current sensor, and the Songle relay. The automatic mode is based on three steps: measurement of the current using ACS712T ELC-30A sensor in all segments except the root; switching off the relays with the current less than or equal to any number in the historical data; switching off the root contactor if all the descendent relays (i.e. contactors are switched off. Second step represents the linear classification with sliding window in machine learning. The software consists of two parts, low-level Arduino sketches and high-level C# Windows form app. They are connected by MQTT broker Mosquitto. The proposed concept was successfully tested using a prototype with three segments, one of which includes smart lighting. The payback period is of approximately one month and a half for the whole-building switch concept.

  2. Chernobyl new safe confinement

    International Nuclear Information System (INIS)

    Dodd, L.

    2011-01-01

    The author presents the new safe confinement that will be commissioned at Unit 4 of the Chernobyl NPP in 2015. The confinement will ensure that Chernobyl Unit 4 will be placed in an environmentally safe condition for at least next 100 years. The article highlights the current work status, future perspectives and the feasibility of confinement concept [ru

  3. Publication of the KTA 3702.1 safety rule of the Kerntechnischer Ausschuss from July 3, 1980. Stand-by units with diesel aggregates in nuclear power plants. Pt. 1

    International Nuclear Information System (INIS)

    1980-01-01

    The rule applies to stationary nuclear power plants. Depending on their application, one of the following diesel aggregates should be chosen: Stand-by aggregates, fast emergency aggregates, or no-delay emergency aggregates. (HP) [de

  4. 77 FR 12059 - Using Innovative Technologies and Other Conditions of Safe Use To Expand Which Drug Products Can...

    Science.gov (United States)

    2012-02-28

    ...] Using Innovative Technologies and Other Conditions of Safe Use To Expand Which Drug Products Can Be... over-the- counter or OTC products) can be purchased by consumers in pharmacies, supermarkets, and other retail establishments without the need for a prescription. Currently, consumers can purchase...

  5. Cellular automata model for traffic flow with safe driving conditions

    International Nuclear Information System (INIS)

    Lárraga María Elena; Alvarez-Icaza Luis

    2014-01-01

    In this paper, a recently introduced cellular automata (CA) model is used for a statistical analysis of the inner microscopic structure of synchronized traffic flow. The analysis focuses on the formation and dissolution of clusters or platoons of vehicles, as the mechanism that causes the presence of this synchronized traffic state with a high flow. This platoon formation is one of the most interesting phenomena observed in traffic flows and plays an important role both in manual and automated highway systems (AHS). Simulation results, obtained from a single-lane system under periodic boundary conditions indicate that in the density region where the synchronized state is observed, most vehicles travel together in platoons with approximately the same speed and small spatial distances. The examination of velocity variations and individual vehicle gaps shows that the flow corresponding to the synchronized state is stable, safe and highly correlated. Moreover, results indicate that the observed platoon formation in real traffic is reproduced in simulations by the relation between vehicle headway and velocity that is embedded in the dynamics definition of the CA model. (general)

  6. Curiosity's Autonomous Surface Safing Behavior Design

    Science.gov (United States)

    Neilson, Tracy A.; Manning, Robert M.

    2013-01-01

    The safing routines on all robotic deep-space vehicles are designed to put the vehicle in a power and thermally safe configuration, enabling communication with the mission operators on Earth. Achieving this goal is made a little more difficult on Curiosity because the power requirements for the core avionics and the telecommunication equipment exceed the capability of the single power source, the Multi-Mission Radioisotope Thermoelectric Generator. This drove the system design to create an operational mode, called "sleep mode", where the vehicle turns off most of the loads in order to charge the two Li-ion batteries. The system must keep the vehicle safe from over-heat and under-heat conditions, battery cell failures, under-voltage conditions, and clock failures, both while the computer is running and while the system is sleeping. The other goal of a safing routine is to communicate. On most spacecraft, this simply involves turning on the receiver and transmitter continuously. For Curiosity, Earth is above the horizon only a part of the day for direct communication to the Earth, and the orbiter overpass opportunities only occur a few times a day. The design must robustly place the Rover in a communicable condition at the correct time. This paper discusses Curiosity's autonomous safing behavior and describes how the vehicle remains power and thermally safe while sleeping, as well as a description of how the Rover communicates with the orbiters and Earth at specific times.

  7. Power Conditioning of Fuel Cell Systems in Portable Applications

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Benitez, E.; Brey, J. J.; Rodriguez-Bordallo, C.; Carrasco, J. M.; Galvan, E.

    2005-07-01

    The achieving of high performance and long useful life are the two fundamental objectives of portable application designers. Cost and size conditions make these objectives more complex and always lead to a compromise solution having to be reached. The most significant parameters as regards portables devices are cost, efficiency (useful life), output crimps and noise, and quiescent current. Most portable products have two fundamental operating modes: active and standby. During the active period, current consumption is generally high and this means that excellent conversion is essential in order to maximize the useful life of the device that supplies current and voltage. However, most portable devices spend most of their time on standby and draw little energy from the source. It is equally important for the source to be very efficient under these conditions. This means that the quiescent current from the source (the current that supplies in low or nil load conditions) must be much lower than the load current in order to maintain high efficiency. Topologies Different power conditioning topologies to be used in portable applications are indicated with their corresponding advantages and inconveniences being specified. Low dropout voltage regulator (LDO) This type of conditioning is one of minimum cost, noise and quiescent current. This makes this device a favorite for many applications. Its external components are minimal: usually a bypass capacity. Its efficiency, although poor when Vin is much greater than Vout, increases greatly when their values are somewhat similar. In this event, the benefits of using LDOs are almost impossible to beat. In fact, these circuits are much used to reach output voltages of up to 3 volts. (Author)

  8. Safe operating envelope

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, N [Ontario Hydro, Toronto, ON (Canada)

    1997-12-01

    Safe Operating Envelope is described representing: The outer bound of plant conditions within which day-to-day plant operation must be maintained in order to comply with regulatory requirements, associated safety design criteria and corporate nuclear safety goals. Figs.

  9. Safe operating envelope

    International Nuclear Information System (INIS)

    Oliva, N.

    1997-01-01

    Safe Operating Envelope is described representing: The outer bound of plant conditions within which day-to-day plant operation must be maintained in order to comply with regulatory requirements, associated safety design criteria and corporate nuclear safety goals. Figs

  10. Fault trees for diagnosis of system fault conditions

    International Nuclear Information System (INIS)

    Lambert, H.E.; Yadigaroglu, G.

    1977-01-01

    Methods for generating repair checklists on the basis of fault tree logic and probabilistic importance are presented. A one-step-ahead optimization procedure, based on the concept of component criticality, minimizing the expected time to diagnose system failure is outlined. Options available to the operator of a nuclear power plant when system fault conditions occur are addressed. A low-pressure emergency core cooling injection system, a standby safeguard system of a pressurized water reactor power plant, is chosen as an example illustrating the methods presented

  11. La "condizionalità" del FMI: per un sistema migliore. (IMF conditionality – a better way

    Directory of Open Access Journals (Sweden)

    J. SPRAOS

    2013-12-01

    Full Text Available L' articolo esamina le condizioni del FMI per la tranche di credito accordi stand-by superiori. L' FMI deve affrontare le critiche che le sue azioni recenti hanno comportato sul ' territorio a causa di errori nei prestiti di banche   ai paesi del terzo mondo banche private - una questione che avrebbe potuto essere lasciata alle forze di mercato libere .Le condizioni di assistenza del FMI dovrebbero concentrarsi non sugli strumenti di politica ma su obiettivi politici , come la crescita , l'occupazione , l'inflazione e , in ultima analisi , il ripristino della bilancia dei pagamenti dei paesi.The article looks at IMF conditions for upper credit tranche stand-by arrangements. The IMF must face the criticism that its recent actions have transgressed on private banks' territory because of banks' errors in lending to third world countries - a matter that could have been left to free market forces. Conditions for IMF aid should focus not on policy instruments but on policy targets, such as growth, employment, inflation and, ultimately, restoration of countries' balance of payments positions. Conditions for IMF help should be centred squarely on the balance of payments of aid-seeking countries if a backwards trend is to be avoided.JEL: F32, F33

  12. The right to adequate and safe working conditions in Ukraine

    Directory of Open Access Journals (Sweden)

    Едуард Валентинович Гаврилов

    2016-06-01

    Full Text Available The special attention is given to the rights of the citizens for independent and safe working conditions. The rights secured by law and guaranteed of each among workers and employers have been considered. The court case on infliction of harm to health in the performance of job duties has been analyzed. Taking this case as an example one can see different possible ways of its solution that cause controversy and contradictions. The Court of First Instance takes the side of the employer, Court of Appeal – on the side of the victim and consideration of the case on cassation appeal - shows only that the state taking the role of the judge is on the employer side not on the side of the worker as a victim. So, one can see that course of the state policy secured by legislators in the numerous normative acts and being reflection of the constitutional principle of the recognition by the state of  the human being, his or her life and health, honour and dignity, inviolability and security as the highest social value that is foreseen by Article 3 and by the provision of Part 4 Article 43 of the Basic Law does not correspond to the realities of life.

  13. PV-Powered CoMP-Based Green Cellular Networks with a Standby Grid Supply

    Directory of Open Access Journals (Sweden)

    Abu Jahid

    2017-01-01

    Full Text Available This paper proposes a novel framework for PV-powered cellular networks with a standby grid supply and an essential energy management technique for achieving envisaged green networks. The proposal considers an emerging cellular network architecture employing two types of coordinated multipoint (CoMP transmission techniques for serving the subscribers. Under the proposed framework, each base station (BS is powered by an individual PV solar energy module having an independent storage device. BSs are also connected to the conventional grid supply for meeting additional energy demand. We also propose a dynamic inter-BS solar energy sharing policy through a transmission line for further greening the proposed network by minimizing the consumption from the grid supply. An extensive simulation-based study in the downlink of a Long-Term Evolution (LTE cellular system is carried out for evaluating the energy efficiency performance of the proposed framework. System performance is also investigated for identifying the impact of various system parameters including storage factor, storage capacity, solar generation capacity, transmission line loss, and different CoMP techniques.

  14. A recursive framework for time-dependent characteristics of tested and maintained standby units with arbitrary distributions for failures and repairs

    International Nuclear Information System (INIS)

    Vaurio, Jussi K.

    2015-01-01

    The time-dependent unavailability and the failure and repair intensities of periodically tested aging standby system components are solved with recursive equations under three categories of testing and repair policies. In these policies, tests or repairs or both can be minimal or perfect renewals. Arbitrary distributions are allowed to times to failure as well as to repair and renewal durations. Major preventive maintenance is done periodically or at random times, e.g. when a true demand occurs. In the third option process renewal is done if a true demand occurs or when a certain mission time has expired since the previous maintenance, whichever occurs first. A practical feature is that even if a repair can renew the unit, it does not generally renew the alternating process. The formalism updates and extends earlier results by using a special backward-renewal equation method, by allowing scheduled tests not limited to equal intervals and accepting arbitrary distributions and multiple failure types and causes, including failures caused by tests, human errors and true demands. Explicit solutions are produced to integral equations associated with an age-renewal maintenance policy. - Highlights: • Time-dependent unavailability, failure count and repair count for a standby system. • Free testing schedule and distributions for times to failure, repair and maintenance. • Multiple failure modes; tests or repairs or both can be minimal or perfect renewals. • Process renewals periodically, randomly or based on the process age or an initiator. • Backward renewal equations as explicit solutions to Volterra-type integral equations

  15. Safe driving for teens

    Science.gov (United States)

    Driving and teenagers; Teens and safe driving; Automobile safety - teenage drivers ... months before taking friends as passengers. Teenage-related driving deaths occur more often in certain conditions. OTHER SAFETY TIPS FOR TEENS Reckless driving is still a ...

  16. Regulations for the safe transport of radioactive material

    International Nuclear Information System (INIS)

    1995-01-01

    Regulations and rules for the safe transport of radioactive materials by all kinds of conveyance are offered. Different types of packages and the conditions associated with the methods of safe packaging are given

  17. Georgia; First Review Under the Stand-By Arrangement-Staff Report; Press Release on the Executive Board Discussion; and Statement by the Executive Director for Georgia

    OpenAIRE

    International Monetary Fund

    2009-01-01

    The staff report for the First Review Under the Stand-By Arrangement with the officials of Georgia highlights economic developments and policies. Sustaining economic growth and maintaining confidence in the currency and the financial system within the constraints of available external financing are the main program priorities. IMF staff recommended a more active role for monetary policy in encouraging market interest rate adjustments. With global markets in distress, the authorities should wo...

  18. Experiences with monitoring and control of microbiological growth in the standby service water system of a BWR nuclear power plant

    International Nuclear Information System (INIS)

    Zisson, P.S.; Whitaker, J.M.; Neilson, H.L.; Mayne, L.L.

    1995-01-01

    In 1989, the Unites States Nuclear Regulatory Commission formally recognized the potential for nuclear accidents resulting from microbiological causes. Such causes range from loss of heat transfer due to microbiological fouling, to loss of system integrity caused by microbiologically influenced corrosion (MIC). As a result of these potential problems, monitoring, mitigation, and control procedures must be developed by all regulated plants. In developing a control and mitigation strategy for the standby service water system of a boiling water reactor (BWR) nuclear power plant, numerous monitoring techniques were employed to evaluate effectiveness. This paper describes the monitoring techniques that were evaluated, and those that ultimately proved to be effective

  19. FFTF and Advanced Reactors Transition Program Resource Loaded Schedule

    Energy Technology Data Exchange (ETDEWEB)

    GANTT, D.A.

    2000-10-31

    This Resource Load Schedule (RLS) addresses two missions. The Advanced Reactors Transition (ART) mission, funded by DOE-EM, is to transition assigned, surplus facilities to a safe and compliant, low-cost, stable, deactivated condition (requiring minimal surveillance and maintenance) pending eventual reuse or D&D. Facilities to be transitioned include the 309 Building Plutonium Recycle Test Reactor (PRTR) and Nuclear Energy Legacy facilities. This mission is funded through the Environmental Management (EM) Project Baseline Summary (PBS) RL-TP11, ''Advanced Reactors Transition.'' The second mission, the Fast Flux Test Facility (FFTF) Project, is funded through budget requests submitted to the Office of Nuclear Energy, Science and Technology (DOE-NE). The FFTF Project mission is maintaining the FFTF, the Fuels and Materials Examination Facility (FMEF), and affiliated 400 Area buildings in a safe and compliant standby condition. This mission is to preserve the condition of the plant hardware, software, and personnel in a manner not to preclude a plant restart. This revision of the Resource Loaded Schedule (RLS) is based upon the technical scope in the latest revision of the following project and management plans: Fast Flux Test Facility Standby Plan (Reference 1); Hanford Site Sodium Management Plan (Reference 2); and 309 Building Transition Plan (Reference 4). The technical scope, cost, and schedule baseline is also in agreement with the concurrent revision to the ART Fiscal Year (FY) 2001 Multi-Year Work Plan (MYWP), which is available in an electronic version (only) on the Hanford Local Area Network, within the ''Hanford Data Integrator (HANDI)'' application.

  20. Development of Start-up and Shutdown Procedure for the HANARO Fuel Test Loop

    International Nuclear Information System (INIS)

    Park, S. K.; Sim, B. S.; Chi, D. Y.; Lee, J. M.; Lee, C. Y.; Ahn, S. H.

    2009-06-01

    A start-up and shutdown procedure for the HANARO fuel test loop has been developed. This is a facility for fuel and material irradiation tests. The facility provides experimental conditions similar to the normal operational pressures and temperatures of commercial PWR and CANDU plants. The normal operation modes of the HANARO fuel test loop are classified into loop shutdown, cold stand-by 1, cold stand-by 2, hot stand-by, and hot operation. The operation modes depend on the fission power of test fuels and the coolant temperature at the inlet of the in-pile test section. The HANARO must maintain a shutdown mode if the HANARO fuel test loop is loop shutdown, cold stand-by 1, cold stand-by 2, or hot stand-by. As the HANARO becomes power operation mode, the operation mode of the HANARO fuel test loop comes to hot operation from hot stand-by. The procedure for the HANARO fuel test loop consists of four main parts such as check of initial conditions, stat-up operation procedure, shutdown operation procedure, and check lists for operations. Several hot test operations ensure that the procedure is appropriate

  1. Safe sex

    Science.gov (United States)

    ... sex; Sexually transmitted - safe sex; GC - safe sex; Gonorrhea - safe sex; Herpes - safe sex; HIV - safe sex; ... contact. STIs include: Chlamydia Genital herpes Genital warts Gonorrhea Hepatitis HIV HPV Syphilis STIs are also called ...

  2. Heuristic hybrid game approach for fleet condition-based maintenance planning

    International Nuclear Information System (INIS)

    Feng, Qiang; Bi, Xiong; Zhao, Xiujie; Chen, Yiran; Sun, Bo

    2017-01-01

    The condition-based maintenance (CBM) method is commonly used to select appropriate maintenance opportunities according to equipment status over a period of time. The CBM of aircraft fleets is a fleet maintenance planning problem. In this problem, mission requirements, resource constraints, and aircraft statuses are considered to find an optimal strategy set. Given that the maintenance strategies for each aircraft are finite, fleet CBM can be treated as a combinatorial optimization problem. In this study, the process of making a decision on the CBM of military fleets is analyzed. The fleet CBM problem is treated as a two-stage dynamic decision-making problem. Aircraft are divided into dispatch and standby sets; thus, the problem scale is significantly reduced. A heuristic hybrid game (HHG) approach comprising a competition game and a cooperative game is proposed on the basis of heuristic rule. In the dispatch set, a competition game approach is proposed to search for a local optimal strategy matrix. A cooperative game method for the two sets is also proposed to ensure global optimization. Finally, a case study regarding a fleet comprising 20 aircraft is conducted, with the results proving that the approach efficiently generates outcomes that meet the mission risk-oriented schedule requirement. - Highlights: • A new heuristic hybrid game method for fleet condition-based maintenance is proposed. • The problem is simplified by hierarchical solving based on dispatch and standby set. • The local optimal solution is got by competition game algorithm for dispatch set. • The global optimal solution is got by cooperative game algorithm between two sets.

  3. Reliability Analysis of a Cold Standby System with Imperfect Repair and under Poisson Shocks

    Directory of Open Access Journals (Sweden)

    Yutian Chen

    2014-01-01

    Full Text Available This paper considers the reliability analysis of a two-component cold standby system with a repairman who may have vacation. The system may fail due to intrinsic factors like aging or deteriorating, or external factors such as Poisson shocks. The arrival time of the shocks follows a Poisson process with the intensity λ>0. Whenever the magnitude of a shock is larger than the prespecified threshold of the operating component, the operating component will fail. The paper assumes that the intrinsic lifetime and the repair time on the component are an extended Poisson process, the magnitude of the shock and the threshold of the operating component are nonnegative random variables, and the vacation time of the repairman obeys the general continuous probability distribution. By using the vector Markov process theory, the supplementary variable method, Laplace transform, and Tauberian theory, the paper derives a number of reliability indices: system availability, system reliability, the rate of occurrence of the system failure, and the mean time to the first failure of the system. Finally, a numerical example is given to validate the derived indices.

  4. Mobile medium-voltage switching system. Temporary standby power supply in record time; Mobile Mittelspannungsschaltanlage. Vorlaeufige Wiederversorgung in Rekordzeit

    Energy Technology Data Exchange (ETDEWEB)

    Thiery, Matthias; Schwarz, Stefan [Siemens AG, Mannheim (Germany); Wingerter, Dieter [BASF SE, Ludwigshafen (Germany); Doering, Holger [B. Goebel und Sohn GmbH, Asschaffenburg (Germany). Fahrzeugbau

    2011-02-28

    BASF SE Ludwigshafen operates more than 100 medium-voltage switching stations for power supply to its plants. The complexity of the production plants and production method make it necessary to have immediate standby power supply in case of interruption of a medium-voltage switching station. For this purpose, a transportable emergency container was acquired that contains a medium-voltage switching system. Power can be supplied at very short notice, simply by plugging the necessary cable connections. No cranes or other tools are required for installation. The emergency container is designed for use at varying voltage levels and can be transported by road to other BASF sites in Europe. The switching station is a gas-insulated medium-voltage switching station 8DA10 by Siemens, designed for operating voltages of 6, 10, 20, and 35 kW.

  5. Smart aircraft fastener evaluation (SAFE) system: a condition-based corrosion detection system for aging aircraft

    Science.gov (United States)

    Schoess, Jeffrey N.; Seifert, Greg; Paul, Clare A.

    1996-05-01

    The smart aircraft fastener evaluation (SAFE) system is an advanced structural health monitoring effort to detect and characterize corrosion in hidden and inaccessible locations of aircraft structures. Hidden corrosion is the number one logistics problem for the U.S. Air Force, with an estimated maintenance cost of $700M per year in 1990 dollars. The SAFE system incorporates a solid-state electrochemical microsensor and smart sensor electronics in the body of a Hi-Lok aircraft fastener to process and autonomously report corrosion status to aircraft maintenance personnel. The long-term payoff for using SAFE technology will be in predictive maintenance for aging aircraft and rotorcraft systems, fugitive emissions applications such as control valves, chemical pipeline vessels, and industrial boilers. Predictive maintenance capability, service, and repair will replace the current practice of scheduled maintenance to substantially reduce operational costs. A summary of the SAFE concept, laboratory test results, and future field test plans is presented.

  6. C-SAFE: A Computer-Delivered Sexual Health Promotion Program for Latinas.

    Science.gov (United States)

    Klein, Charles H; Kuhn, Tamara; Altamirano, Midori; Lomonaco, Carmela

    2017-07-01

    This article describes the development and evaluation of C-SAFE (Sexual Awareness for Everyone), a computer-delivered sexual health promotion program for Latinas. We first describe the process of adapting an evidence-based, group-level intervention into an individually administered computer-delivered program. We then present the methods and results of a randomized control trial with 321 Latinas in California and Florida to test C-SAFE's preliminary efficacy in reducing sexual health risk. We found no statistically significant differences between the two conditions at a six-month follow-up in terms of sexual behaviors or attitudes toward sexually transmitted infections and condoms, although C-SAFE women reported fewer days in the past month when their mental health was not good (p = .02). C-SAFE condition women also reported more satisfaction than control condition women in their assessment of information presentation (on a scale of 1 = poor and 5 = excellent; C-SAFE = 4.45 vs. control = 4.25, p = .053) and having learned something new (C-SAFE = 95.1% vs. control = 79.3%, χ 2 importance of teachable moments, matching of delivery modalities to implementation contexts, and possible directions for evidence-based sexual health promotion programs given the current sexual health landscape.

  7. Parameter Estimation of a Reliability Model of Demand-Caused and Standby-Related Failures of Safety Components Exposed to Degradation by Demand Stress and Ageing That Undergo Imperfect Maintenance

    Directory of Open Access Journals (Sweden)

    S. Martorell

    2017-01-01

    Full Text Available One can find many reliability, availability, and maintainability (RAM models proposed in the literature. However, such models become more complex day after day, as there is an attempt to capture equipment performance in a more realistic way, such as, explicitly addressing the effect of component ageing and degradation, surveillance activities, and corrective and preventive maintenance policies. Then, there is a need to fit the best model to real data by estimating the model parameters using an appropriate tool. This problem is not easy to solve in some cases since the number of parameters is large and the available data is scarce. This paper considers two main failure models commonly adopted to represent the probability of failure on demand (PFD of safety equipment: (1 by demand-caused and (2 standby-related failures. It proposes a maximum likelihood estimation (MLE approach for parameter estimation of a reliability model of demand-caused and standby-related failures of safety components exposed to degradation by demand stress and ageing that undergo imperfect maintenance. The case study considers real failure, test, and maintenance data for a typical motor-operated valve in a nuclear power plant. The results of the parameters estimation and the adoption of the best model are discussed.

  8. A geometric process repair model for a repairable cold standby system with priority in use and repair

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Wang Guanjun

    2009-01-01

    In this paper, a deteriorating cold standby repairable system consisting of two dissimilar components and one repairman is studied. For each component, assume that the successive working times form a decreasing geometric process while the consecutive repair times constitute an increasing geometric process, and component 1 has priority in use and repair. Under these assumptions, we consider a replacement policy N based on the number of repairs of component 1 under which the system is replaced when the number of repairs of component 1 reaches N. Our problem is to determine an optimal policy N* such that the average cost rate (i.e. the long-run average cost per unit time) of the system is minimized. The explicit equation of the average cost rate of the system is derived and the corresponding optimal replacement policy N* can be determined analytically or numerically. Finally, a numerical example with Weibull distribution is given to illustrate some theoretical results in this paper.

  9. Is nuclear power safe enough

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, A F [Institutt for Atomenergi, Kjeller (Norway)

    1979-01-01

    The lecture formed a commentary on the report of the Norwegian Government's Commission on Nuclear power Safety which was published in October 1978. It was introductorily pointed out that 'safe' and 'safety' are not in themselves meaningful terms and that the probability of an occurrence is the real measure. The main items in the Commission's report have been core meltdown, releases during reprocessing, waste disposal, plutonium diversion and environmental impacts. The 21 members of the Commission were unanimous in 7 of the 8 chapters. In chapter 2, 'Summary and Conclusions', 3 members dissented from the majority opinion, that, subject to certain conditions, nuclear power was a safe and acceptable source of energy.

  10. Project management plan for Reactor 105-C Interim Safe Storage project

    International Nuclear Information System (INIS)

    Plagge, H.A.

    1996-09-01

    Reactor 105-C (located on the Hanford Site in Richland, Washington) will be placed into an interim safe storage condition such that (1) interim inspection can be limited to a 5-year frequency; (2) containment ensures that releases to the environmental are not credible under design basis conditions; and (3) final safe storage configuration shall not preclude or significantly increase the cost for any decommissioning alternatives for the reactor assembly.This project management plan establishes plans, organizational responsibilities, control systems, and procedures for managing the execution of Reactor 105-C interim safe storage activities to meet programmatic requirements within authorized funding and approved schedules

  11. 76 FR 12719 - Safe Schools/Healthy Students Program; Office of Safe and Drug-Free Schools; Safe Schools/Healthy...

    Science.gov (United States)

    2011-03-08

    ... DEPARTMENT OF EDUCATION Safe Schools/Healthy Students Program; Office of Safe and Drug- Free Schools; Safe Schools/Healthy Students Program; Catalog of Federal Domestic Assistance (CFDA) Numbers: 84... priorities, requirements, and definitions under the Safe Schools/Healthy Students (SS/HS) program. Since...

  12. Safeguards Automated Facility Evaluation (SAFE) methodology

    International Nuclear Information System (INIS)

    Chapman, L.D.; Grady, L.M.; Bennett, H.A.; Sasser, D.W.; Engi, D.

    1978-08-01

    An automated approach to facility safeguards effectiveness evaluation has been developed. This automated process, called Safeguards Automated Facility Evaluation (SAFE), consists of a collection of a continuous stream of operational modules for facility characterization, the selection of critical paths, and the evaluation of safeguards effectiveness along these paths. The technique has been implemented on an interactive computer time-sharing system and makes use of computer graphics for the processing and presentation of information. Using this technique, a comprehensive evaluation of a safeguards system can be provided by systematically varying the parameters that characterize the physical protection components of a facility to reflect the perceived adversary attributes and strategy, environmental conditions, and site operational conditions. The SAFE procedure has broad applications in the nuclear facility safeguards field as well as in the security field in general. Any fixed facility containing valuable materials or components to be protected from theft or sabotage could be analyzed using this same automated evaluation technique

  13. Solving the maintenance dilemma of ageing controls in nuclear standby generators. The decision to retro-fit the control system with 'off the shelf technology'

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Neil [Turbine Controls Ltd Canada, 5288 General Rd, L4W 1Z8 Mississauga (Canada); Rees, Christpher [Turbine Controls Ltd UK, 52 Kenilworth Drive, LE2 5LG Leicester (United Kingdom); Yeremain, Joseph [Thermodyne, 421 Nugget Avenue Unit 3, Toronto Ontario M1S 4L8 (Canada)

    2010-07-01

    Blackouts - Are we 2 Steps away from Nuclear meltdown owing to Aging Controls? The intent of this white paper is to high-light the need to:- 1. Replace the aging control systems associated with critical safety equipment of Standby Generators in the nuclear environment. 2. Explain how 'off the shelf' standard control equipment may be suitably selected, integrated and tested for a nuclear environment. 3. High-light the lessons learned in respect of: - a. Qualification of COTS (commercial off the shelf) equipment for use in a nuclear application. b. Software quality assurance program. c. Reducing plant outage time. 4. Guide you on the selection criteria of credible partners that can implement such mission critical control systems. Causes for Concern - The control systems of some of the Standby Generators are 30+ years old and aging equipment is no longer available from the OEM's. Maintenance crews are evolving with young engineers who have no experience, or chance to be trained, on the old installed control base. The writer has no doubt that the extent of the black outs of North America, Aug 2003, and the standby generators ever reducing availability, has compromised their ability to provide essential service and communications to maintain the safety of the nuclear plant. These concerns prompted Ontario Power Generator and Bruce Power to review the reliability of their standby generators and this review prompted them to locate a suitable supplier for the task of replacing the control system. OPG's previous attempts to have the controls replaced by I and C dedicated companies weighed heavy on their minds. Worsening the dilemma was the fact that it used dedicated controls and what might be considered 'Propriety Software'. Black Outs - Not only is it possible, the probability of it happening is getting stronger The Northeast Blackout of 2003 was a massive widespread power outage that occurred throughout parts of the North-eastern and

  14. Cool and Safe: Multiplicity in Safe Innovation at Unilever

    Science.gov (United States)

    Penders, Bart

    2011-01-01

    This article presents the making of a safe innovation: the application of ice structuring protein (ISP) in edible ices. It argues that safety is not the absence of risk but is an active accomplishment; innovations are not "made safe afterward" but "safe innovations are made". Furthermore, there are multiple safeties to be accomplished in the…

  15. Safe affordable fission engine (SAFE 30) module conductivity test thermal model correlation

    International Nuclear Information System (INIS)

    Roman, Jose

    2001-01-01

    The SAFE 30 is a simple, robust space fission power system that is comprised of several independent modules. Each module contains 4 fuel tubes bonded to a central heatpipe. Fission energy is conducted from the fuel tubes to the heatpipe, which in turn transfers the energy to a power conversion system. This paper benchmarks a thermal model of the SAFE 30 with actual test data from simulated SAFE 30 module tests. Two 'dummy' SAFE 30 modules were fabricated - each consisted of 4 1-inch dia. tubes (simulating the fuel tubes) bonded to a central '1' dia. tube (simulating the heatpipe). In the first module the fuel tubes were simply brazed to the heatpipe along the line of contact (leaving void space in the interstices), and in the second module the tubes and heatpipe were brazed via tri-cusps that completely fill the interstices between the tubes. In these tests, fission energy is simulated by placing resistance heaters within each of the 4 fuel tubes. The tests were conducted in a vacuum chamber in 4 configurations: tri-cusps filled with and without an outer insulation wrap, and no tri-cusps with and without an outer insulation wrap. The baseline SAFE 30 configuration uses the brazed tri-cusps. During the tests, the power applied to the heaters was varied in a stepwise fashion, until a steady-state temperature profile was reached. These temperature levels varied between 773 K and 1073 K. To benchmark the thermal model, the input energy and chamber surface temperature were used as boundary conditions for the model. The analytical results from the nodes at the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis by varying the surface emissivity and view factor until a good match was reached. This

  16. El Salvador; Request for a Stand-By Arrangement and Cancellation of Current Arrangement: Staff Report; Press Release on the Executive Board Discussion; and Statement by the Executive Director for El Salvador

    OpenAIRE

    International Monetary Fund

    2010-01-01

    This paper discusses El Salvador’s Request for a Stand-By Arrangement and cancellation of the current arrangement. The program seeks to preserve financial stability, safeguard the economic recovery, and strengthen the medium-term fiscal position. Fiscal policy will aim at offsetting the impact of the adverse external environment on domestic activity and the most vulnerable while ensuring debt sustainability over the medium term. IMF financial support would have a catalytic role for official c...

  17. TAN Hot Shop and Support Facility Utilization Study

    Energy Technology Data Exchange (ETDEWEB)

    Picker, B.A.

    2001-11-16

    Impacts to the U.S. Department of Energy (DOE) complex caused by early closure (prior to 2018) and Demolition and Dismantlement (D and D) of the Test Area North (TAN) hot shop and its support facilities are explored in this report. Various possible conditions, such as Standby, Safe Store and Lay-up, that the facility may be placed in prior to eventually being turned over to D and D are addressed. The requirements, impacts, and implications to the facility and to the DOE Complex are discussed for each condition presented in the report. Some details of the report reference the Idaho National Engineering and Environmental Laboratory (INEEL) Spent Nuclear Fuel Life Cycle Baseline Plan, the INEEL 2000 Infrastructure Long Range Plan, and other internal INEEL reports.

  18. TAN HOT SHOP AND SUPPORT FACILITY UTILIZATION STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Ken Crawforth

    2001-11-01

    Impacts to the U.S. Department of Energy (DOE) complex caused by early closure (prior to 2018) and Demolition and Dismantlement (D&D) of the Test Area North (TAN) hot shop and its support facilities are explored in this report. Various possible conditions, such as Standby, Safe Store and Lay-up, that the facility may be placed in prior to eventually being turned over to D&D are addressed. The requirements, impacts, and implications to the facility and to the DOE Complex are discussed for each condition presented in the report. Some details of the report reference the Idaho National Engineering and Environmental Laboratory (INEEL) Spent Nuclear Fuel Life Cycle Baseline Plan, the INEEL 2000 Infrastructure Long Range Plan, and other internal INEEL reports.

  19. Asymptotically Safe Standard Model via Vectorlike Fermions

    Science.gov (United States)

    Mann, R. B.; Meffe, J. R.; Sannino, F.; Steele, T. G.; Wang, Z. W.; Zhang, C.

    2017-12-01

    We construct asymptotically safe extensions of the standard model by adding gauged vectorlike fermions. Using large number-of-flavor techniques we argue that all gauge couplings, including the hypercharge and, under certain conditions, the Higgs coupling, can achieve an interacting ultraviolet fixed point.

  20. How safe is safe enough?

    International Nuclear Information System (INIS)

    Desnoyers, B.; Chanzy, Y.

    2004-01-01

    The IAEA Regulations for the Safe Transport of Radioactive Material, were historically established with the objective to reduce the probability that persons be exposed to unacceptable doses due to normal operation or accident situations during transport of radioactive material. Based on the International Basic Safety Standards for Protection against Ionizing Radiation (BSS), the definition, which was adopted for an unacceptable dose for an accident situation, is the excess of the maximum dose limits permissible in a single year for the occupational exposure of a worker in the BSS. Concerning the severity of accident situations, it has always be clearly stated that the objective of the tests for demonstrating ability to withstand accident conditions of transport was not to cover every accident condition, but solely most of them. The last available evaluations regarding the rate of accidents which are covered by the standardised accident conditions of transport defined in the IAEA Regulations give a range of about 80%, plus or minus 15% which depends on transport mode and studies. Consequently, slight variations in the capabilities of the packages to meet the specified performance would probably not have significant consequences on the protection level in case of accident. In the assessment of the compliance with the regulations, the tendency of experts, taking advantage of the enhanced performances of computer calculation codes, is to ask more and more calculations, with more and more accuracy, leading to more and more restrictions. Consequently, cost and delay are considerably increased without any evidence of an equivalent effect on the level of protection. This paper will initiate a reflection on the general objectives and principles when implementing the Regulations, in such a way that demonstrations remain cost effective, taking into account evolution of the techniques and a high level of safety

  1. Use of Frequency Distribution Functions to Establish Safe Conditions in Relation to the Foodborne Pathogen Bacillus cereus

    Directory of Open Access Journals (Sweden)

    Begoña Delgado

    2005-01-01

    Full Text Available Minimal processing implementation greatly depends on a detailed knowledge of the effects of preservation factors and their combinations on the spoilage and foodborne pathogenic microorganisms. The effectiveness of mild preservation conditions will become increasingly dependent on a more stochastic approach linking microbial physiological factors with product preservation factors. In this study, the validity of frequency distributions to efficiently describe the inactivation and growth of Bacillus cereus in the presence of natural antimicrobials (essential oils has been studied. For this purpose, vegetative cells were exposed to 0.6 mM of thymol or cymene, obtaining survival curves that were best described by the distribution of Weibull, since a tailing effect was observed. B. cereus was also exposed in a growth medium to a low concentration (0.1 mM of both antimicrobials, separately or combined, and the lag times obtained were fitted to a normal distribution, which allowed a description of dispersion of the start of growth. This allowed a more efficient evaluation of the experimental data to establish safe processing conditions according to accurate parameters and their implementation in risk assessment.

  2. FY 2000 Development of technologies for reducing power consumption during the stand-by period. Report on the research and development results of rationally reducing power consumption by home electric appliances; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden seihin no taikiji shohi denryoku no goriteki sakugen ni kansuru kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research and development project is implemented for development of the system which automatically switches off the power source for a standing-by appliance by analyzing life pattern in each home, in order to reduce consumed power during the stand-by period. The actual service conditions of appliances in each home are surveyed through the questionnaires and recording in the diary. The analysis results indicate that as high as 70% of those who are inquired take interest in energy saving, especially high among full-time housewives. The home electric appliances considered by many to wastefully consume power are functional-keeping types, e.g., (jar pots) and (toilet seats equipped with a washing function with warm water), and heating appliances, e.g., (hot carpets). The power consumption trends at each time in each home are measured and grasped by the aid of a tool with built-in personal computer, and the algorithm for predicting use of the appliances in each home is developed for each home, based on the analysis results. The prototype energy-saving adapter and centralized controller are developed, and subjected to various tests to develop the learning/controlling algorithms. The demonstration tests of the energy-saving adapter developed confirm that power consumption during the stand-by period can be reduced at least by 10%. (NEDO)

  3. Progress and experiences from the decommissioning of the eurochemic reprocessing plant

    International Nuclear Information System (INIS)

    Gillis, R.; Lewandowski, P.; Ooms, B.; Reusen, N.; Van Laer, W.; Walthery, R.

    2008-01-01

    The Eurochemic reprocessing facility at Dessel in Belgium, was constructed from 1960 to 1966. After shutdown, the plant was decontaminated from 1975 to 1979 to keep safe standby conditions at reasonable cost. When it was decided in 1986 not to resume reprocessing in Belgium, the main Belgoprocess activities changed to processing and storage of radioactive waste and to decontamination and decommissioning of obsolete nuclear facilities. The industrial decommissioning was started in 1990. This document presents the project: overview of decommissioning activities and equipment used, automation in decontamination, ensuring health and safety during the operations, release of decontaminated materials, current situation of the decommissioning activities and quality assurance program. (A.L.B.)

  4. LACK OF AWARENESS ABOUT SAFE BLOOD IN PAKISTANI POPULATION

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2014-12-01

    Full Text Available Blood transfusion is a life saving procedure in various transfusion-dependent life threatening conditions and donation of safe blood is a prerequisite for achieving this goal. This study was designed to evaluate the awareness regarding “safe blood” in Pakistani population. This study was conducted at a large scale through a population survey. The test population was divided into two groups i.e. general population and students. The Performa was designed for a general and student population and included 20 questions related to awareness of safe blood. A total of 4900 individuals belonging to different ethnic groups were included in this population survey. Results of social survey were analyzed by using Usman and Moin awareness chart. Results of this study revealed profound unawareness about safe blood in Pakistani population. This study found lack of awareness about safe blood as a major factor that is playing a vital role in the propagation of blood borne diseases in Pakistan. To secure the recipients from blood borne complications through blood donation, it is necessary to create effective awareness about safe blood in Pakistani population.

  5. The SafeCOP ECSEL Project: Safe Cooperating Cyber-Physical Systems Using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Hansson, Hans

    2016-01-01

    This paper presents an overview of the ECSEL project entitled "Safe Cooperating Cyber-Physical Systems using Wireless Communication" (SafeCOP), which runs during the period 2016 -- 2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  6. The application of redundancy-related basic safety principles to the 1400 MWE reactor core standby cooling system

    International Nuclear Information System (INIS)

    Bertrand, R.

    1990-01-01

    This memorandum shall provide the background for the work of the European Community Commission which is to analyze safety principles relating to redundancy. The redundancy-related basic safety principles applied in French nuclear power plants are the following: . the single-failure criterion, . provisions additional to application of the single-failure criterion. These are mainly provisions made at the design stage to minimize risks associated with common cause failures or the risks of human error which can lead to such failures: - protection against hazards of internal and external origin, - the geographical or physical separation of equipment, - the independence of electrical power supplies and distribution systems, - the additional resources and associated operating procedures making it possible to accommodate total loss of the safety systems. The scope also includes the operating rules which ensure availability of redundant safety-related equipment. The provisions relating to the single-failure criterion are detailed in Basic Safety Rule 1.3.A appended. The application of these principles proposed by the operating organization and accepted by the safety authorities for the design and operation of the standby core cooling system (System RIS) is explained

  7. Safe Kids Worldwide

    Science.gov (United States)

    ... Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters Who We Are What We Do Find Your Safe Kids Safe Kids Day Main menu Keeping All Kids Safe Safety Tips Get Involved 4 Star Charity Donate Text Burns and Scalds 4 tips ...

  8. Prospects of the Economic Community of West African States Standby Force

    National Research Council Canada - National Science Library

    Amponsem-Boateng, Richard

    2006-01-01

    .... Political instability, conflicts and economic deprivation breeds failed states. In addition to wanton human sufferings, failed states can provide safe havens for terrorist and other international crime...

  9. Active and reactive power for seconds stand-by reserve. Efficiency and profitability of different measures in power plants and networks. Wirkleistung- und Blindleistung-Sekundenreserve. Wirksamkeit und Wirtschaftlichkeit verschiedener Massnahmen in Kraftwerken und Netzen

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    The various methods used for releasing active and reactive power reserves in the seconds range have different static and dynamics effects and involve different investment and operation cost. This two-day conference concerns different methods available to power plants and network for seconds stand-by reserve based on network requirements. Measurements and simulation studies are compared to assess the efficiency of individual methods. The profitability of individual methods is assessed in a comparative study.

  10. Safe delivery practices: experience from cross-sectional data of Bangladeshi women.

    Science.gov (United States)

    Kabir, M A; Goh, Kim-Leng; Khan, M M H; Al-Amin, Abul Quasem; Azam, Mohammad Nurul

    2015-03-01

    This study examines the safe delivery practices of Bangladeshi women using data on 4905 ever-married women aged 15 to 49 years from the 2007 Bangladesh Demographic and Health Survey. Variables that included age, region of origin, education level of respondent and spouse, residence, working status, religion, involvement in NGOs, mass media exposure, and wealth index were analyzed to find correlates of safe delivery practices. More than 80% of the deliveries took place at home, and only 18% were under safe and hygienic conditions. The likelihood of safe deliveries was significantly lower among younger and older mothers than middle-aged mothers and higher among educated mothers and those living in urban areas. Economically better-off mothers and those with greater exposure to mass media had a significantly higher incidence of safe delivery practices. A significant association with religion and safe delivery practices was revealed. Demographic, socioeconomic, cultural, and programmatic factors that are strongly associated with safe delivery practices should be considered in the formulation of reproductive health policy. © 2012 APJPH.

  11. Commercial experience with facility deactivation to safe storage

    Energy Technology Data Exchange (ETDEWEB)

    Sype, T.T. [Sandia National Labs., Albuquerque, NM (United States); Fischer, S.R. [Los Alamos National Lab., NM (United States); Lee, J.H. Jr.; Sanchez, L.C.; Ottinger, C.A.; Pirtle, G.J. [Sandia National Labs., Albuquerque, NM (United States)

    1995-09-01

    The Department of Energy (DOE) has shutdown many production reactors; the Department has begun a major effort to also shutdown a wide variety of other nuclear facilities. Because so many facilities are being closed, it is necessary to place many of them into a safe- storage status, i.e., deactivation, before conducting decommissioning- for perhaps as long as 20 years. The challenge is to achieve this safe-storage condition in a cost-effective manner while remaining in compliance with applicable regulations. The DOE Office of Environmental Management, Office of Transition and Management, commissioned a lessons-learned study of commercial experience with safe storage and decommissioning. Although the majority of the commercial experience has been with reactors, many of the lessons learned presented in this document can provide insight into transitioning challenges that Will be faced by the DOE weapons complex.

  12. Commercial experience with facility deactivation to safe storage

    International Nuclear Information System (INIS)

    Sype, T.T.; Fischer, S.R.; Lee, J.H. Jr.; Sanchez, L.C.; Ottinger, C.A.; Pirtle, G.J.

    1995-09-01

    The Department of Energy (DOE) has shutdown many production reactors; the Department has begun a major effort to also shutdown a wide variety of other nuclear facilities. Because so many facilities are being closed, it is necessary to place many of them into a safe- storage status, i.e., deactivation, before conducting decommissioning- for perhaps as long as 20 years. The challenge is to achieve this safe-storage condition in a cost-effective manner while remaining in compliance with applicable regulations. The DOE Office of Environmental Management, Office of Transition and Management, commissioned a lessons-learned study of commercial experience with safe storage and decommissioning. Although the majority of the commercial experience has been with reactors, many of the lessons learned presented in this document can provide insight into transitioning challenges that Will be faced by the DOE weapons complex

  13. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  14. Solving the maintenance dilemma of ageing controls in nuclear standby generators. The decision to retro-fit the control system with 'off the shelf technology'

    International Nuclear Information System (INIS)

    Jackson, Neil; Rees, Christpher; Yeremain, Joseph

    2010-01-01

    Blackouts - Are we 2 Steps away from Nuclear meltdown owing to Aging Controls? The intent of this white paper is to high-light the need to:- 1. Replace the aging control systems associated with critical safety equipment of Standby Generators in the nuclear environment. 2. Explain how 'off the shelf' standard control equipment may be suitably selected, integrated and tested for a nuclear environment. 3. High-light the lessons learned in respect of: - a. Qualification of COTS (commercial off the shelf) equipment for use in a nuclear application. b. Software quality assurance program. c. Reducing plant outage time. 4. Guide you on the selection criteria of credible partners that can implement such mission critical control systems. Causes for Concern - The control systems of some of the Standby Generators are 30+ years old and aging equipment is no longer available from the OEM's. Maintenance crews are evolving with young engineers who have no experience, or chance to be trained, on the old installed control base. The writer has no doubt that the extent of the black outs of North America, Aug 2003, and the standby generators ever reducing availability, has compromised their ability to provide essential service and communications to maintain the safety of the nuclear plant. These concerns prompted Ontario Power Generator and Bruce Power to review the reliability of their standby generators and this review prompted them to locate a suitable supplier for the task of replacing the control system. OPG's previous attempts to have the controls replaced by I and C dedicated companies weighed heavy on their minds. Worsening the dilemma was the fact that it used dedicated controls and what might be considered 'Propriety Software'. Black Outs - Not only is it possible, the probability of it happening is getting stronger The Northeast Blackout of 2003 was a massive widespread power outage that occurred throughout parts of the North-eastern and Midwestern United States and Ontario

  15. Keeping you safe by making machine tools safe

    CERN Multimedia

    2012-01-01

    CERN’s third safety objective for 2012 concerns the safety of equipment - and machine tools in particular.   There are three prerequisites for ensuring that a machine tool can be used safely: ·      the machine tool must comply with Directive 2009/104/EC, ·      the layout of the workshop must be compliant, and ·      everyone who uses the machine tool must be trained. Provided these conditions are met, the workshop head can grant authorisation to use the machine tool. To fulfil this objective, an inventory of the machine tools must be drawn up and the people responsible for them identified. The HSE Unit's Safety Inspection Service produces compliance reports for the machine tools. In order to meet the third objective set by the Director-General, the section has doubled its capacity to carry out inspections: ...

  16. Selection of appropriate conditioning matrices for the safe disposal of radioactive waste

    International Nuclear Information System (INIS)

    Vance, E.R.

    2002-01-01

    The selection of appropriate solid conditioning matrices or wasteforms for the safe disposal of radioactive waste is dictated by many factors. The overriding issue is that the matrix incorporating the radionuclides, together with a set of engineered barriers in a near-surface or deep geological repository, should prevent significant groundwater transport of radionuclides to the biosphere. For high-level waste (HLW) from nuclear fuel reprocessing, the favored matrices are glasses, ceramics and glass-ceramics. Borosilicate glasses are presently being used in some countries, but there are strong scientific arguments why ceramics based on assemblages of natural minerals are advantageous for HLW. Much research has been carried out in the last 40 years around the world, and different matrices are more suitable than others for a given waste composition. However a major stumbling block for HLW immobilisation is the mall number of approved geological repositories for such matrices. The most appropriate matrices for Intermediate and low-level wastes are contentious and the selection criteria are not very well defined. The candidate matrices for these latter wastes are cements, bitumen, geopolymers, glasses, glass-ceramics and ceramics. After discussing the pros and cons of various candidate matrices for given kinds of radioactive wastes, the SYNROC research program at ANSTO will be briefly surveyed. Some of the potential applications of this work using a variety of SYNROC derivatives will be given. Finally the basic research program at ANSTO on radioactive waste immobilisation will be summarised. This comprises mainly work on solid state chemistry to understand ionic valences and co-ordinations for the chemical design of wasteforms, aqueous durability to study the pH and temperature dependence of solid-water reactions, radiation damage effects on structure and solid-water reactions. (Author)

  17. Conditional live virus as a novel approach towards a safe live attenuated HIV vaccine

    NARCIS (Netherlands)

    Das, Atze T.; Zhou, Xue; Vink, Monique; Klaver, Bep; Berkhout, Ben

    2002-01-01

    To control the worldwide spread of HIV, a safe and effective prophylactic vaccine is urgently needed. Studies with the simian immunodeficiency virus demonstrated that a live attenuated virus can be effective as a vaccine, but serious concerns about the safety of such a vaccine virus have arisen. We

  18. How did aviation become so safe, and beyond?

    NARCIS (Netherlands)

    Stoop, J.A.A.M.

    2017-01-01

    Aviation has been recognized as one of the ultimate safe socio-technical systems. This contribution discusses the conditions and context that moulded the system safety to its present level by applying integral safety, a sectoral approach and safety as a strategic value. At present the aviation

  19. DroidSafe

    Science.gov (United States)

    2016-12-01

    Massachusetts Avenue, Build E19-750 Cambridge , MA 02139-4307 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS...Activity objects illustrating the challenges of points-to and information flow analysis...measure how many malicious flows Droid- Safe was able to detect). As these results illustrate , DroidSafe implements an analysis of unprece- dented

  20. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  1. Safe havens in Europe

    DEFF Research Database (Denmark)

    Paldam, Martin

    2013-01-01

    Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11 countries are richer than their large neighbors. It is shown that causality is from small to safe haven to wealth, and that theoretically...... equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity...... of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds....

  2. Traveling Safely with Medicines

    Science.gov (United States)

    ... Medications Safely My Medicine List How to Administer Traveling Safely with Medicines Planes, trains, cars – even boats ... your trip, ask your pharmacist about how to travel safely with your medicines. Make sure that you ...

  3. Inherently safe in situ uranium recovery

    Science.gov (United States)

    Krumhansl, James L; Brady, Patrick V

    2014-04-29

    An in situ recovery of uranium operation involves circulating reactive fluids through an underground uranium deposit. These fluids contain chemicals that dissolve the uranium ore. Uranium is recovered from the fluids after they are pumped back to the surface. Chemicals used to accomplish this include complexing agents that are organic, readily degradable, and/or have a predictable lifetime in an aquifer. Efficiency is increased through development of organic agents targeted to complexing tetravalent uranium rather than hexavalent uranium. The operation provides for in situ immobilization of some oxy-anion pollutants under oxidizing conditions as well as reducing conditions. The operation also artificially reestablishes reducing conditions on the aquifer after uranium recovery is completed. With the ability to have the impacted aquifer reliably remediated, the uranium recovery operation can be considered inherently safe.

  4. The Safe Transportation of Radioactive Materials

    International Nuclear Information System (INIS)

    Megrahi, Abdulhafeed; Abu-Ali, Giuma; Enhaba; Ahmed

    2008-01-01

    In this paper, we present the essential conditions that should be required for transporting the radioactive materials. We demonstrate the procedure for transporting the radioactive iodine-131 from the Centre of Renewable Energies and Desalination of Water in Tajoura, Libya to Tripoli Medical Center. The safe measures were taken during the process of the transportation of the isotope produced in the centre including dosimetry analysis and the thickness of the container. (author)

  5. Cost-competitive, inherently safe LFMBR pool plant

    International Nuclear Information System (INIS)

    McDonald, J.S.; Brunings, J.E.; Chang, Y.I.; Hren, R.R.; Seidensticker, R.W.

    1984-01-01

    The Cost-Competitive, Inherently Safe LMFBR Pool Plant design was prepared in GFY 1983 under a DOE-sponsored program. This plant design was developed as a joint effort by Rockwell International and the Argonne National Laboratory with major contributions from the Bechtel Group, Inc.; Combustion engineering, Inc.; the Chicago Bridge and Iron Company; and the General Electric Company. Using current LMFBR technology, many innovative features were developed and incorporated into the design to meet the ultimate objectives of the Breeder Program, i.e., energy costs competitive with LWRs and inherent safety features to maintain the plant in a safe condition following assumed accidents without requiring operator action. This paper provides a description of the principal features that were incorporated into the design to achieve low cost and inherent safety

  6. Concept of an inherently-safe high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Sato, Hiroyuki; Tachibana, Yukio; Kunitomi, Kazuhiko; Ogawa, Masuro

    2012-01-01

    As the challenge to ensure no harmful release of radioactive materials at the accidents by deterministic approach instead to satisfy acceptance criteria or safety goal for risk by probabilistic approach, new concept of advanced reactor, an inherently-safe high temperature gas-cooled reactor, is proposed based on the experience of the operation of the actual High Temperature Gas-cooled Reactor (HTGR) in Japan, High Temperature Engineering Test Reactor (HTTR), and the design of the commercial plant (GTHTR300), utilizing the inherent safety features of the HTGR (i.e., safety features based on physical phenomena). The safety design philosophy of the inherently-safe HTGR for the safety analysis of the radiological consequences is determined as the confinement of radioactive materials is assured by only inherent safety features without engineered safety features, AC power or prompt actions by plant personnel if the design extension conditions occur. Inherent safety features to prevent the loss or degradation of the confinement function are identified. It is proposed not to apply the probabilistic approach for the evaluation of the radiological consequences of the accidents in the safety analysis because no inherent safety features fail for the mitigation of the consequences of the accidents. Consequently, there are no event sequences to harmful release of radioactive materials if the design extension conditions occur in the inherently-safe HTGR concept. The concept and future R and D items for the inherently-safe HTGR are described in this paper.

  7. Calendar aging of a 250 kW/500 kWh Li-ion battery deployed for the grid storage application

    Science.gov (United States)

    Kubiak, Pierre; Cen, Zhaohui; López, Carmen M.; Belharouak, Ilias

    2017-12-01

    The introduction of Li-ion batteries for grid applications has become evidence as the cost per kWh is continuously decreasing. Although the Li-ion battery is a mature technology for automotive applications and portable electronics, its use for stationary applications needs more validation. The Li-ion technology is considered safe enough for grid storage application, but its lifetime is generally evaluated to be around 10 years. Higher market penetration will be achieved if a longer lifespan could be demonstrated. Therefore, aging evaluation of the batteries becomes crucial. In this paper we investigated the effects of aging after a three years' standby field deployment of a 250 kW/500 kWh Li-ion battery integrated with the grid and solar farm under the harsh climate conditions of Qatar. The development of tools for acquisition and analysis of data from the battery management system (BMS) allows the assessment of the battery performance at the battery stack, string and cell levels. The analysis of the residual capacity after aging showed that the stack suffered from a low decrease of capacity, whereas some inconsistencies have been found between the strings. These inconsistencies are caused by misalignment of a small number of cells that underwent self-discharge during standby at high state of charge.

  8. The Design of The Monitoring Tools Of Clean Air Condition And Dangerous Gas CO, CO2 CH4 In Chemical Laboratory By Using Fuzzy Logic Based On Microcontroller

    Science.gov (United States)

    Widodo, Slamet; Miftakul, Amin M.; Sutrisman, Adi

    2018-02-01

    There are many phenomena that human are exposed to toxins from certain types such as of CO2, CO2 and CH4 gases. The device used to detect large amounts of CO, CO2, and CH4 gas in air in enclosed spaces using MQ 135 gas sensors of different types based on the three sensitivity of the Gas. The results of testing the use of sensors MQ 135 on the gas content of CO, CO2 and CH4 received by the sensor is still in the form of ppm based on the maximum ppm detection range of each sensor. Active sensor detects CO 120 ppm gas, CO2 1600 ppm and CH4 1ppm "standby 1" air condition with intermediate rotary fan. Active sensor detects CO 30 ppm gas, CO2 490 ppm and CH4 7 ppm "Standby 2" with low rotating fan output. Fuzzy rulebase logic for motor speed when gas detection sensor CO, CO2, and CH4 output controls the motion speed of the fan blower. Active sensors detect CO 15 ppm, CO2 320 ppm and CH4 45 ppm "Danger" air condition with high fan spin fan. At the gas level of CO 15 ppm, CO2 390 ppm and CH4 3 ppm detect "normal" AC sensor with fan output stop spinning.

  9. The pressurized suit and some considerations leading to the development of physiologically safe working conditions

    International Nuclear Information System (INIS)

    Evans, J.C.

    1980-01-01

    The safe working environment of men wearing pressurized suits in the U.K.A.E.A. is based on the results of two experimental programmes, the first investigated the respiratory hazards, the second the assessment and control of the level of thermal stress. Both are described. (author)

  10. SAFE Newsletter

    OpenAIRE

    2013-01-01

    The Center of Excellence SAFE – “Sustainable Architecture for Finance in Europe” – is a cooperation of the Center for Financial Studies and Goethe University Frankfurt. It is funded by the LOEWE initiative of the State of Hessen (Landes-Offensive zur Entwicklung wissenschaftlich-ökonomischer Exzellenz). SAFE brings together more than 40 professors and just as many junior researchers who are all dedicated to conducting research in support of a sustainable financial architecture. The Center has...

  11. Elaboration of Safe Community Assessment System

    Directory of Open Access Journals (Sweden)

    Birutė Mikulskienė

    2013-08-01

    Full Text Available The paper aims to design an assessment system to monitor and evaluate safety parameters and administrative efforts with the purpose to increase safety in municipalities. The safety monitoring system considered is to be the most important tool for creation and development of safe communities in Lithuania. Several methods were applied to achieve this purpose. In order to determine the role of local government in ensuring the safety of people, property and environment at the local level of a meta-analysis of research reports, the Lithuanian national legislation, strategic planning documents of the state and local government were carried out. Analysis of statistical data, structural analysis, comparative analysis and synthesis methods were used while investigating the areas of safety uncertainty, risk groups, identifying safety risk factors, determining their relationship, and creating a safe community assessment system. A safe community assessment system, which consists of two types of criteria, has been elaborated. The assessment system is based on the multi-level criteria for safety monitoring and the multi-level criteria for the evaluation of municipal activities in the field of building safety. Links between the criteria, peculiarities of their application and advantages in the process of safe community creation and development are analyzed. Design and implementation of the safe community assessment system is one of the most important stages to implement the idea of safe communities. The proposed system integrates a variety of risk areas, the safety achievement criteria are linked to the criteria used in the strategic planning. Periodic assessment of the safety situation using the proposed system ensures possibility to monitor current local safety conditions and assess the changes and the trends. A safe community assessment system is proposed to be used as a tool to unified municipalities safety comprehensiveness and compare safety level in

  12. Elaboration of Safe Community Assessment System

    Directory of Open Access Journals (Sweden)

    Algirdas Astrauskas

    2011-12-01

    Full Text Available The paper aims to design an assessment system to monitor and evaluate safety parameters and administrative efforts with the purpose to increase safety in municipalities. The safety monitoring system considered is to be the most important tool for creation anddevelopment of safe communities in Lithuania. Several methods were applied to achieve this purpose. In order to determine the role of local government in ensuring the safety of people, property and environment at the local level of a meta-analysis of research reports,the Lithuanian national legislation, strategic planning documents of the state and local government were carried out. Analysis of statistical data, structural analysis, comparative analysis and synthesis methods were used while investigating the areas of safety uncertainty, risk groups, identifying safety risk factors, determining their relationship, and creating a safe community assessment system.A safe community assessment system, which consists of two types of criteria, has been elaborated. The assessment system is based on the multi-level criteria for safety monitoring and the multi-level criteria for the evaluation of municipal activities in the field of building safety. Links between the criteria, peculiarities of their application and advantages in the process of safe community creation and development are analyzed.Design and implementation of the safe community assessment system is one of the most important stages to implement the idea of safe communities. The proposed system integrates a variety of risk areas, the safety achievement criteria are linked to the criteria used in thestrategic planning. Periodic assessment of the safety situation using the proposed system ensures possibility to monitor current local safety conditions and assess the changes and the trends. A safe community assessment system is proposed to be used as a tool to unified municipalities safety comprehensiveness and compare safety level in

  13. A Sensitivity Study of Human Errors in Optimizing Surveillance Test Interval (STI) and Allowed Outage Time (AOT) of Standby Safety System

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Shin, Won Ky; You, Young Woo; Yang, Hui Chang

    1998-01-01

    In most cases, the surveillance test intervals (STIs), allowed outage times (AOTS) and testing strategies of safety components in nuclear power plant are prescribed in plant technical specifications. And, in general, it is required that standby safety system shall be redundant (i.e., composed of multiple components) and these components are tested by either staggered test strategy or sequential test strategy. In this study, a linear model is presented to incorporate the effects of human errors associated with test into the evaluation of unavailability. The average unavailabilities of 1/4, 2/4 redundant systems are computed considering human error and testing strategy. The adverse effects of test on system unavailability, such as component wear and test-induced transient have been modelled. The final outcome of this study would be the optimized human error domain from 3-D human error sensitivity analysis by selecting finely classified segment. The results of sensitivity analysis show that the STI and AOT can be optimized provided human error probability is maintained within allowable range. (authors)

  14. Safe Grid

    Science.gov (United States)

    Chow, Edward T.; Stewart, Helen; Korsmeyer, David (Technical Monitor)

    2003-01-01

    The biggest users of GRID technologies came from the science and technology communities. These consist of government, industry and academia (national and international). The NASA GRID is moving into a higher technology readiness level (TRL) today; and as a joint effort among these leaders within government, academia, and industry, the NASA GRID plans to extend availability to enable scientists and engineers across these geographical boundaries collaborate to solve important problems facing the world in the 21 st century. In order to enable NASA programs and missions to use IPG resources for program and mission design, the IPG capabilities needs to be accessible from inside the NASA center networks. However, because different NASA centers maintain different security domains, the GRID penetration across different firewalls is a concern for center security people. This is the reason why some IPG resources are been separated from the NASA center network. Also, because of the center network security and ITAR concerns, the NASA IPG resource owner may not have full control over who can access remotely from outside the NASA center. In order to obtain organizational approval for secured remote access, the IPG infrastructure needs to be adapted to work with the NASA business process. Improvements need to be made before the IPG can be used for NASA program and mission development. The Secured Advanced Federated Environment (SAFE) technology is designed to provide federated security across NASA center and NASA partner's security domains. Instead of one giant center firewall which can be difficult to modify for different GRID applications, the SAFE "micro security domain" provide large number of professionally managed "micro firewalls" that can allow NASA centers to accept remote IPG access without the worry of damaging other center resources. The SAFE policy-driven capability-based federated security mechanism can enable joint organizational and resource owner approved remote

  15. Conditioning experience for spent radium sources

    International Nuclear Information System (INIS)

    Kang, I. S.; Shon, J. S.; Kim, K. J.; Min, D. K.

    2001-01-01

    In order to avoid accidents that could be resulted from improper storage of spent radium sources, it is necessary to condition and store them safely. The program for safe conditioning of spent radium sources by IAEA has been established to assist the developing countries. The main object of this paper is to apply the technology that was adapted by IAEA for the conditioning the national inventory of Ra-226 sources in member states, as a part of IAEA's project with the Korean expert team. This paper is the result that the Korean expert team carried out spent radium conditioning, under the project title 'Radium Conditioning in Myanmar(INT4131-06646C)'. The whole inventory of spent radium sources 1,429.5mCi, was safely conditioned by the Korean expert team according to the manual under the supervision of IAEA's technical officer and the control of Myanmar authority on behalf of Myanmar. These sources were encapsuled and welded into 27 small capsules and 3 large capsules, and conditioned in 3 lead shields, producing 3 concrete-shielded drums. The inventories were distributed into 3 shielding devices, holding 500mCi, 459.5mCi, and 470mCi

  16. Safety analysis to support a safe operating envelope for fuel

    International Nuclear Information System (INIS)

    Gibb, R.A.; Reid, P.J.

    1998-01-01

    This paper presents an approach for defining a safe operating envelope for fuel. 'Safe operating envelope' is defined as an envelope of fuel parameters defined for application in safety analysis that can be related to, or used to define, the acceptable range of fuel conditions due to operational transients or deviations in fuel manufacturing processes. The paper describes the motivation for developing such a methodology. The methodology involved four steps: the update of fission product inventories, the review of sheath failure criteria, a review of input parameters to be used in fuel modelling codes, and the development of an improved fission product release code. This paper discusses the aspects of fuel sheath failure criteria that pertain to operating or manufacturing conditions and to the evaluation and selection of modelling input data. The other steps are not addressed in this paper since they have been presented elsewhere. (author)

  17. Questions of the clinical estimation of bronchopulmonary system status of the personnel which will participate in works on transformation 'Shelter object' in radioecologically safe condition

    International Nuclear Information System (INIS)

    Sushko, V.A.; Shvajko, L.I.

    2002-01-01

    The given data indicate that for victims of the ChNPP accident (primarily clean-up workers) presence of bronchological pathology in the form of chronic obstructive pulmonary disease with some special clinical, endoscopes, pathomorphological and immunological features appeared typical. That requires the adequate methodology elaboration of diagnostics and treatment of bronchopulmonary diseases for the given contingent. Thus, the personnel directed on works, connected with transformation 'Shelter Object' (ShO) in radioecologically safe condition should have complex pulmonological maintenance at all stages of medicosanitary support

  18. Safe cycling!

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    The HSE Unit will be running a cycling safety campaign at the entrances to CERN's restaurants on 14, 15 and 16 May. Pop along to see if they can persuade you to get back in the saddle!   With summer on its way, you might feel like getting your bike out of winter storage. Well, the HSE Unit has come up with some original ideas to remind you of some of the most basic safety rules. This year, the prevention campaign will be focussing on three themes: "Cyclists and their equipment", "The bicycle on the road", and "Other road users". This is an opportunity to think about the condition of your bike as well as how you ride it. From 14 to 16 May, representatives of the Swiss Office of Accident Prevention and the Touring Club Suisse will join members of the HSE Unit at the entrances to CERN's restaurants to give you advice on safe cycling (see box). They will also be organising three activity stands where you can test your knowle...

  19. Conditioning technology of spent radium sources

    International Nuclear Information System (INIS)

    Kang, Il Sik; Kim, K. J.; Jang, K. D.

    2001-03-01

    In order to avoid accidents that could be resulted from improper storage of spent radium sources, it is necessary to condition and store them safely. The program for safe conditioning of spent radium sources by IAEA has been established to assist the developing countries. The main object of this report is to understand well and apply the technology that was applied in conditioning the national inventory of Ra-226 sources in Myanmar, as a part of IAEA's project by the Korean expert team. The report is the result that the Korean expert team carried out in Myanmar under the project title 'Radium Conditioning Service in Myanmar(INT4131-06646C)'. As a result of the mission, a whole inventory, 1,429.5 mCi of spent radium sources was safely conditioned by the Korean expert team according to the manual under the supervision of IAEA's technical officer, Mr. Al-Mughrabi, and under the control of DAE authority. These sources were encapsuled in 27 small capsules and 3 large capsules, and conditioned in 3 lead shields, producing 3 packages. The inventories were distributed into 3 shielding devices, holding 500, 459.5, and 470 mCi

  20. Peru; Third Review and Inflation Consultation Under the Stand-By Arrangement and Request for Waiver of Applicability of Performance Criteria: Staff Report; Staff Supplement; Press Release on the Executive Board Discussion; and Statement by the Executive Director for Peru

    OpenAIRE

    International Monetary Fund

    2008-01-01

    This paper discusses key findings of the Third Review for Peru and Inflation Consultation Under the Stand-By Arrangement. All performance criteria for end-December 2007 and end-March 2008 were observed, but inflation in March exceeded the upper limit of the program’s consultation band around the official inflation target range. The end-March structural benchmark was observed and progress has been made on end-June benchmarks. The outlook for 2008 remains favorable, with the economy continuing ...

  1. Performance of some silver sorbents for control of radioiodine from nuclear fuel operations

    International Nuclear Information System (INIS)

    Scheele, R.D.; Burger, L.L.; Halko, B.T.; Waters, E.D.; Orme, R.M.

    1989-01-01

    The Process Facility Modification (PFM) proposed for the Hanford PUREX plant includes control of gaseous radioiodine. In support of the Westinghouse Hanford Company (WHC) design effort for the PFM, the Pacific Northwest Laboratory (PNL) has evaluated caustic scrubbing and the use of silver-containing solid sorbents to remove iodine from the dissolver offgas (DOG) stream. The present report describes the behavior of several silver-containing zeolites and silver nitrate-impregnated silicic acid tested under conditions simulating normal and standby operation of the PFM. These studies found that the silver zeolites, Norton silver mordenite (NAgZ), Linde silver mordenite (LAgZ), and partially silver-exchanged Linde silver faujasite (PAgX), can routinely reduce the gaseous iodine concentration in a simulated PFM DOG to -5 μmol I/L, while a commercially produced silver nitrate-impregnated silicic acid (AgNO 3 Si) could not at these test conditions. Tests simulating standby operation of beds loaded up to 0.25 μmol I/g sorbent indicate that standby operation will not result in effluent concentrations above 10 -5 μmol I/L. At higher loadings standby operation initially caused iodine to migrate from NAgZ. There were indications that the iodine tends to stabilize with time, but insufficient information is available to fully characterize these reactions

  2. Are Detox Diets Safe?

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Are Detox Diets Safe? KidsHealth / For Teens / Are Detox Diets ... seguras las dietas de desintoxicación? What Is a Detox Diet? The name sounds reassuring — everyone knows that ...

  3. Organising a safe space for navigating social-ecological transformations to sustainability

    NARCIS (Netherlands)

    L. Pereira (Laura); T. Karpouzoglou (Timothy); S. Doshi (Samir); N. Frantzeskaki (Niki)

    2015-01-01

    textabstractThe need for developing socially just living conditions for the world’s growing population whilst keeping human societies within a ‘safe operating space’ has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and

  4. Organising a safe space for navigating social-ecological transformations to sustainability

    NARCIS (Netherlands)

    Pereira, L.; Karpouzoglou, T.D.; Doshi, S.; Frantzeskaki, N.

    2015-01-01

    The need for developing socially just living conditions for the world’s growing population whilst keeping human societies within a ‘safe operating space’ has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and management regimes

  5. III-V Ultra-Thin-Body InGaAs/InAs MOSFETs for Low Standby Power Logic Applications

    Science.gov (United States)

    Huang, Cheng-Ying

    As device scaling continues to sub-10-nm regime, III-V InGaAs/InAs metal- oxide-semiconductor ?eld-e?ect transistors (MOSFETs) are promising candidates for replacing Si-based MOSFETs for future very-large-scale integration (VLSI) logic applications. III-V InGaAs materials have low electron effective mass and high electron velocity, allowing higher on-state current at lower VDD and reducing the switching power consumption. However, III-V InGaAs materials have a narrower band gap and higher permittivity, leading to large band-to-band tunneling (BTBT) leakage or gate-induced drain leakage (GIDL) at the drain end of the channel, and large subthreshold leakage due to worse electrostatic integrity. To utilize III-V MOSFETs in future logic circuits, III-V MOSFETs must have high on-state performance over Si MOSFETs as well as very low leakage current and low standby power consumption. In this dissertation, we will report InGaAs/InAs ultra-thin-body MOSFETs. Three techniques for reducing the leakage currents in InGaAs/InAs MOSFETs are reported as described below. 1) Wide band-gap barriers: We developed AlAs0.44Sb0.56 barriers lattice-match to InP by molecular beam epitaxy (MBE), and studied the electron transport in In0.53Ga0.47As/AlAs 0.44Sb0.56 heterostructures. The InGaAs channel MOSFETs using AlAs0.44Sb0.56 bottom barriers or p-doped In0.52 Al0.48As barriers were demonstrated, showing significant suppression on the back barrier leakage. 2) Ultra-thin channels: We investigated the electron transport in InGaAs and InAs ultra-thin quantum wells and ultra-thin body MOSFETs (t ch ~ 2-4 nm). For high performance logic, InAs channels enable higher on-state current, while for low power logic, InGaAs channels allow lower BTBT leakage current. 3) Source/Drain engineering: We developed raised InGaAs and recessed InP source/drain spacers. The raised InGaAs source/drain spacers improve electrostatics, reducing subthreshold leakage, and smooth the electric field near drain, reducing

  6. Super-compactor and grouting. Efficient and safe treatment of nuclear waste

    International Nuclear Information System (INIS)

    Li, Hongyou; Starke, Holger; Muetzel, Wolfgang; Winter, Marc

    2014-01-01

    The conditioning and volume reduction of nuclear waste are increasingly important factors throughout the world. Efficient and safe treatment of nuclear waste therefore plays a decisive role. Babcock Noell designed, manufactured and supplied a complete waste treatment facility for conditioning of the solid radioactive waste of a nuclear power plant to China. This facility consists of a Sorting Station, a Super-Compactor, a Grouting Unit with Capping Device and other auxiliary equipment which is described in more detail in the following article. This article gives an overview of the efficient and safe treatment of nuclear waste. Babcock Noell is a subsidiary of the Bilfinger Power Systems and has 40 years of experience in the field of design, engineering, construction, static and dynamic calculations, manufacturing, installation, commissioning, as well as in the service and operation of a wide variety of nuclear components and facilities worldwide.

  7. Safe Anesthesia For Every Tot

    DEFF Research Database (Denmark)

    Weiss, Markus; Vutskits, Laszlo; Hansen, Tom G

    2015-01-01

    PURPOSE OF REVIEW: The term 'safe use of anesthesia in children is ill-defined and requires definition of and focus on the 'safe conduct of pediatric anesthesia'. RECENT FINDINGS: The Safe Anesthesia For Every Tot initiative (www.safetots.org) has been set up during the last year to focus...... on the safe conduct of pediatric anesthesia. This initiative aims to provide guidance on markers of quality anesthesia care. The introduction and implementation of national regulations of 'who, where, when and how' are required and will result in an improved perioperative outcome in vulnerable children....... The improvement of teaching, training, education and supervision of the safe conduct of pediatric anesthesia are the main goals of the safetots.org initiative. SUMMARY: This initiative addresses the well known perioperative risks in young children, perioperative causes for cerebral morbidity as well as gaps...

  8. ETHEL's systems and facilities for safe management of tritiated wastes

    International Nuclear Information System (INIS)

    Mannone, F.; Dworschak, H.; Vassallo, G.

    1992-01-01

    The European Tritium Handling Experimental Laboratory (ETHEL) is a new tritium facility at the Commission of the European Community's Joint Research Centre, Ispra Site. The laboratory, destined to handle multigram amounts of tritium for safety related R and D purposes, is foreseen to start radioactive operations in late 1992. The general operation and maintenance of laboratory systems and future experiments will generate tritiated wastes in gaseous, liquid and solid forms. The management of such wastes under safe working conditions is a stringent laboratory requirement aimed at minimizing the risk of unacceptable tritium exposures to workers and the general public. This paper describes the main systems and facilities installed in ETHEL for the safe management of tritiated wastes

  9. Conditioning of spent radiation sources in developing countries

    International Nuclear Information System (INIS)

    1990-01-01

    This video presents the safe handling and conditioning of radioactive spent sealed sources when technological resources are limited and specialized equipment is not available. The process is divided into three phases which are demonstrated in detail: 1) Planning, including training; 2) Conditioning, which is the actual incorporation of the spent sources; and 3) Follow-up, which includes radiological control, documentation and safe storage

  10. PFP supply fan motor starters

    International Nuclear Information System (INIS)

    Keck, R.D.

    1995-01-01

    The Plutonium Finishing Plant (PFP) is currently stabilizing about 25 kg of Pu sludge; upon completion of this task, PFP will be maintained in a safe standby condition to await decision from the PFP NEPA review. It can take about 10 years to initiate and complete terminal cleanout after this; the facility will then be decommissioned and decontaminated. The 234-5Z ventilation system must continue to operate until terminal cleanout. Part of the ventilation system is the seismic fan shutdown system which shuts down the ventilation supply fans in case of strong earthquake. This document presents criteria for installing solid state, reduced voltage motor starters and isolation contactors for the 8 main ventilation supply fans. The isolation contactors will shutdown the supply fans in event of earthquake

  11. Conditions Of Safe Ship Operations And Sea Waterway Parameters Based On The Reconstruction Of Świnoujście-Szczecin Fairway

    Directory of Open Access Journals (Sweden)

    Gucma Stanisław

    2015-09-01

    Full Text Available This paper describes the state vector of safe ship operation on sea waterways. The author determines relationships between the state vector of safe ship operation and parameters of sea waterway system elements. These include three subsystems: area, navigation and traffic control. These relationships have been exemplified with the 68-kilometre Świnoujście-Szczecin fairway, presently under reconstruction. A systematic approach to sea waterway design is globally unique.

  12. Predicting soil acidification trends at Plynlimon using the SAFE model

    Directory of Open Access Journals (Sweden)

    B. Reynolds

    1997-01-01

    Full Text Available The SAFE model has been applied to an acid grassland site, located on base-poor stagnopodzol soils derived from Lower Palaeozoic greywackes. The model predicts that acidification of the soil has occurred in response to increased acid deposition following the industrial revolution. Limited recovery is predicted following the decline in sulphur deposition during the mid to late 1970s. Reducing excess sulphur and NOx deposition in 1998 to 40% and 70% of 1980 levels results in further recovery but soil chemical conditions (base saturation, soil water pH and ANC do not return to values predicted in pre-industrial times. The SAFE model predicts that critical loads (expressed in terms of the (Ca+Mg+K:Alcrit ratio for six vegetation species found in acid grassland communities are not exceeded despite the increase in deposited acidity following the industrial revolution. The relative growth response of selected vegetation species characteristic of acid grassland swards has been predicted using a damage function linking growth to soil solution base cation to aluminium ratio. The results show that very small growth reductions can be expected for 'acid tolerant' plants growing in acid upland soils. For more sensitive species such as Holcus lanatus, SAFE predicts that growth would have been reduced by about 20% between 1951 and 1983, when acid inputs were greatest. Recovery to c. 90% of normal growth (under laboratory conditions is predicted as acidic inputs decline.

  13. PERANGKAT LUNAK SEMI HOT STANDBY ROUTER PROTOCOL PADA PC ROUTER BERBASIS LINUX

    Directory of Open Access Journals (Sweden)

    Nur Aini Rakhmawati

    2005-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Router memegang peranan penting dalam sebuah jaringan. Jika router mengalami suatu masalah dapat berakibat terhambatnya lalu lintas data dalam suatu jaringan. Untuk mengatasi masalah sebuah router, Cisco mengembangkan suatu sistem Hot Standby Router Protocol (HSRP. Namun HSRP ini belum dimiliki oleh router komputer. Padahal harga komputer lebih murah daripada router hardware. Semi HSRP merupakan suatu metode yang diimplementasikan pada router komputer dengan keterbatasan yang dimiliki oleh sebuah komputer dimana sebuahrouter komputer tidak dapat mengirimkan pesan resign yang mengijikan router lain untuk menggantikannyaketika router komputer ini mengalami kegagalan. Dalam semi HSRP dibentuk suatu kelompok router yang memiliki subnet yang sama pada masing-masing interfacenya.Pada masing-masing router dijalankan aplikasi yang berfungsi untuk mengatur jalannya mekanisme HSRP. Aplikasi ini memungkinkan router-router tersebut dapat berhubungan untuk mengetahui apakah ada masalah yang terjadi pada router utama yang berfungsi untuk meneruskan data klien dengan menggunakan alamat virtual IP dan MAC. Dalam berhubungan router-router tersebut menggunakan komunikasi broadcast. Ketika router utama mengalami kegagalan maka

  14. SAFE/SNAP application to shipboard security

    International Nuclear Information System (INIS)

    Grady, L.M.; Walker, J.L.; Polito, J.

    1981-11-01

    An application of the combined Safeguards Automated Facility Evaluation/Safeguards Network Analysis Procedure (SAFE/SNAP) modeling technique to a physical protection system (PPS) aboard a generic ship is described. This application was performed as an example of how the SAFE and SNAP techniques could be used. Estimates of probability of interruption and neutralization for the example shipboard PPS are provided by SAFE as well as an adversary scenario, which serves as input to SNAP. This adversary scenario is analyzed by SNAP through four cases which incorporate increasingly detailed security force tactics. Comparisons between the results of the SAFE and SNAP analyses are made and conclusions drawn on the validity of each technique. Feedback from SNAP to SAFE is described, and recommendations for upgrading the ship based on the results of the SAFE/SNAP application are also discussed

  15. Early detection of power system disturbances as a condition for safe operation of the Dukovany NPP in the 'Island operation mode'

    International Nuclear Information System (INIS)

    Petruzela, I.

    1997-01-01

    The ''Frequency Plan'' worked out for the Czech Power System specifies a set of preventive measures along with the set of the frequency ranges. This problem was solved in details for the Dukovany nuclear power plant. The design changes under preparation support a reliable as well as safe operation in the island-operation mode until a full restoration of the whole power system. The design modifications are based on the following three main innovations: An incorporation of the FREA 16 frequency relay into the protection circuits; large modifications in turbine control loops; installation of software routine for the operator to support the island operation mode. The capability of the island operation has been demanded by relevant regulations both for the operating units and for that under construction. The capability can be tested under the transition to houseloads, as well as through the direct simulation of abnormal grid conditions. 1 fig

  16. Asymptotically Safe Dark Matter

    DEFF Research Database (Denmark)

    Sannino, Francesco; Shoemaker, Ian M.

    2015-01-01

    We introduce a new paradigm for dark matter (DM) interactions in which the interaction strength is asymptotically safe. In models of this type, the coupling strength is small at low energies but increases at higher energies, and asymptotically approaches a finite constant value. The resulting...... searches are the primary ways to constrain or discover asymptotically safe dark matter....

  17. 75 FR 1734 - Children’s Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; i-SAFE...

    Science.gov (United States)

    2010-01-13

    ... Proposed Self-Regulatory Guidelines; i-SAFE, Inc. Application for Safe Harbor AGENCY: Federal Trade... for public comment concerning proposed self-regulatory guidelines submitted by i-SAFE, Inc. under the... approval self-regulatory guidelines that would implement the Rule's protections.\\3\\ \\1\\ 64 FR 59888 (1999...

  18. Patient Involvement in Safe Delivery: A Qualitative Study.

    Science.gov (United States)

    Olfati, Forozun; Asefzadeh, Saeid; Changizi, Nasrin; Keramat, Afsaneh; Yunesian, Masud

    2015-09-28

    Patient involvement in safe delivery planning is considered important yet not widely practiced. The present study aimed at identifythe factors that affect patient involvementin safe delivery, as recommended by parturient women. This study was part of a qualitative research conducted by content analysis method and purposive sampling in 2013.The data were collected through 63 semi-structured interviews in4 hospitalsand analyzed using thematic content analysis. The participants in this research were women before discharge and after delivery. Findings were analyzed using Colaizzi's method. Four categories of factors that could affect patient involvement in safe delivery emerged from our analysis: patient-related (true and false beliefs, literacy, privacy, respect for patient), illness-related (pain, type of delivery, patient safety incidents), health care professional-relatedand task-related factors (behavior, monitoring &training), health care setting-related (financial aspects, facilities). More research is needed to explore the factors affecting the participation of mothers. It is therefore, recommended to: 1) take notice of mother education, their husbands, midwives and specialists; 2) provide pregnant women with insurance coverage from the outset of pregnancy, especially during prenatal period; 3) form a labor pain committee consisting of midwives, obstetricians, and anesthesiologists in order to identify the preferred painless labor methods based on the existing facilities and conditions, 4) carry out research on observing patients' privacy and dignity; 5) pay more attention on the factors affecting cesarean.

  19. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  20. When is it safe to fly? Addressing medical conditions in pilots.

    Science.gov (United States)

    Steinkraus, Lawrence

    2011-06-01

    Since World War I, the role of physicians who care for pilots has been to minimize the risks posed by the unique environment in airplanes and the demands of flying. Originally, that meant screening out those with any physical limitations that might affect their ability to fly such as vision or cardiac problems. Today, however, with the ability to better manage patients with multiple conditions, the physician's task is more nuanced and requires an estimation of risk based on the how well a pilot's condition can be managed and the type of flying he or she does. This article looks at how pilots are medically evaluated and how the standards for medical certification are evolving, allowing some pilots who have certain conditions to continue flying.

  1. Declarative Modelling and Safe Distribution of Healthcare Workflows

    DEFF Research Database (Denmark)

    Hildebrandt, Thomas; Mukkamala, Raghava Rao; Slaats, Tijs

    2012-01-01

    We present a formal technique for safe distribution of workflow processes described declaratively as Nested Condition Response (NCR) Graphs and apply the technique to a distributed healthcare workflow. Concretely, we provide a method to synthesize from a NCR Graph and any distribution of its events......-organizational case management. The contributions of this paper is to adapt the technique to allow for nested processes and milestones and to apply it to a healthcare workflow identified in a previous field study at danish hospitals....

  2. Light water ultra-safe plant concept

    International Nuclear Information System (INIS)

    Klevans, E.

    1989-01-01

    Since the accident at Three Mile Island (TMI), Penn State Nuclear Engineering Department Faculty and Staff have considered various methods to improve already safe reactor designs and public perception of the safety of Nuclear Power. During 1987 and 1988, the Department of Energy provided funds to the Nuclear Engineering Department at Penn State to investigate a plant reconfiguration originated by M.A. Schultz called ''The Light Water Ultra-Safe Plant Concept''. This report presents a final summary of the project with references to several masters' theses and addendum reports for further detail. The two year research effort included design verification with detailed computer simulation of: (a) normal operation characteristics of the unique pressurizing concept, (b) severe transients without loss of coolant, (c) combined primary and secondary system modeling, and (d) small break and large break loss of coolant accidents. Other studies included safety analysis, low power density core design, and control system design to greatly simplify the control room and required operator responses to plant upset conditions. The overall conclusion is that a reconfigured pressurized water reactor can achieve real and perceived safety improvements. Additionally, control system research to produce greatly simplified control rooms and operator requirements should be continued in future projects

  3. Qualification of conditioning process

    International Nuclear Information System (INIS)

    Wolf, J.

    1989-01-01

    A conditioning process is qualified by the PTB if the execution of pre-treatment and conditioning occurs so that a safe and orderly final storage of the products and waste containers produced can be assumed. All the relevant operating conditions for the plant are laid down by the producer/conditioner of the waste in a handbook. The elements of product inspection by process qualification are shown in tabular form. (DG) [de

  4. Lessons learned from commercial experience with nuclear plant decontamination to safe storage

    International Nuclear Information System (INIS)

    Fischer, S.R.; Partain, W.L.; Sype, T.

    1995-01-01

    The Department of Energy (DOE) has successfully performed decontamination and decommissioning (D ampersand D) on many production reactors it. DOE now has the challenge of performing D ampersand D on a wide variety of other nuclear facilities. Because so many facilities are being closed, it is necessary to place many of them into a safe-storage status before conducting D ampersand D-for perhaps as much as 20 yr. The challenge is to achieve this safe-storage condition in a cost-effective manner while remaining in compliance with applicable regulations. The DOE Office of Environmental Management, Office of Transition and Management, commissioned a lessons learned study of commercial experience with safe storage and transition to D ampersand D. Although the majority of the commercial experience has been with reactors, many of the lessons learned presented in this paper are directly applicable to transitioning the DOE Weapons Complex

  5. 77 FR 75402 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2012-12-20

    ... illumination of the ``STANDBY BUS OFF'' light, which led the flightcrew to set the standby power switch to the... This AD was prompted by a standby power relay failure and subsequent illumination of the ``STANDBY BUS OFF'' light, which led the flightcrew to set the standby power switch to the ``BAT'' position...

  6. Procedure of safe handling with cytostatic drugs

    Directory of Open Access Journals (Sweden)

    Kodžo Dragan

    2003-01-01

    Full Text Available Working group for safe handling with cytostatic drugs has been formed by the Ministry of Health, and it consists of professionals from IORS, Federal Bureau of Weights and Measures, Industrial Medicine, Institute of Hematology, Military Medical Academy, and Crown Agents. The aim of this working group is to prepare procedures for safe handling with cytostatic drugs, as well as program for educational seminar for nurses, medical technicians, and pharmaceutical technicians. The procedures will serve as a guide of good practice of oncology health care, and will refer to all actions that health care professionals carry out from the moment of drugs arrival to the pharmacy to the moment of their application. In the first segment of this procedure, general rules are given for working with cytotoxic agents, control for risky exposures, safe system of work, control of working environment, monitoring of the employees' health condition adequate protection in the working environment, protective equipment of the employees (gloves, mask, cap, eyeglasses, shoe covers, coats and chambers for vertical laminary air stream. Storing of cytostatics, procedure in case of accident, and waste handling and removal are also described in this segment. Fifty-three standard operational procedures are described in detail in the second segment. Training scheme for preparation of chemotherapy is given in the third segment - education related to various fields and practical part, which would be carried out through workshops, and at the end of the course participants would pass a test and obtain certificate. After the procedures for safe handling with cytostatics are legally regulated employer will have to provide minimum of protective equipment, special rooms for the drugs dissolving, chambers with laminar airflow, 6 hours working time, rotation of the staff working with drugs dissolving in intervals of every five years, higher efficiency, better health control. In conclusion

  7. Safe Cooperating Cyber-Physical Systems using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Sljivo, Irfan

    2017-01-01

    This paper presents an overview of the ECSEL project entitled ―Safe Cooperating Cyber-Physical Systems using Wireless Communication‖ (SafeCOP), which runs during the period 2016–2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  8. Policing behaviors, safe injection self-efficacy, and intervening on injection risks: Moderated mediation results from a randomized trial.

    Science.gov (United States)

    Pitpitan, Eileen V; Patterson, Thomas L; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A

    2016-01-01

    We aim to use conditional or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico, and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. In total, 213 women provided complete data for the current analyses. Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = .04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = .04). Whereas syringe confiscation by the police negatively affected safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to "buffer" this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants' self-efficacy for safer injection in the face of syringe confiscation. (c) 2015 APA, all rights reserved).

  9. When the Safe Alternative Is Not That Safe: Tramadol Prescribing in Children

    Directory of Open Access Journals (Sweden)

    Frédérique Rodieux

    2018-03-01

    Full Text Available Children represent a vulnerable population in which management of nociceptive pain is complex. Drug responses in children differ from adults due to age-related differences. Moreover, therapeutic choices are limited by the lack of indication for a number of analgesic drugs due to the challenge of conducting clinical trials in children. Furthermore the assessment of efficacy as well as tolerance may be complicated by children’s inability to communicate properly. According to the World Health Organization, weak opioids such as tramadol and codeine, may be used in addition to paracetamol and ibuprofen for moderate nociceptive pain in both children and adults. However, codeine prescription has been restricted for the last 5 years in children because of the risk of fatal overdoses linked to the variable activity of cytochrome P450 (CYP 2D6 which bioactivates codeine. Even though tramadol has been considered a safe alternative to codeine, it is well established that tramadol pharmacodynamic opioid effects, efficacy and safety, are also largely influenced by CYP2D6 activity. For this reason, the US Food and Drug Administration recently released a boxed warning regarding the use of tramadol in children. To provide safe and effective tramadol prescription in children, a personalized approach, with dose adaptation according to CYP2D6 activity, would certainly be the safest method. We therefore recommend this approach in children requiring chronic or recurrent nociceptive pain treatment with tramadol. In case of acute inpatients nociceptive pain management, prescribing tramadol at the minimal effective dose, in a child appropriate dosage form and after clear instructions are given to the parents, remains reasonable based on current data. In all other situations, morphine should be preferred for moderate to severe nociceptive pain conditions.

  10. InaSAFE applications in disaster preparedness

    Science.gov (United States)

    Pranantyo, Ignatius Ryan; Fadmastuti, Mahardika; Chandra, Fredy

    2015-04-01

    Disaster preparedness activities aim to reduce the impact of disasters by being better prepared to respond when a disaster occurs. In order to better anticipate requirements during a disaster, contingency planning activities can be undertaken prior to a disaster based on a realistic disaster scenario. InaSAFE is a tool that can inform this process. InaSAFE is a free and open source software that estimates the impact to people and infrastructure from potential hazard scenarios. By using InaSAFE, disaster managers can develop scenarios of disaster impacts (people and infrastructures affected) to inform their contingency plan and emergency response operation plan. While InaSAFE provides the software framework exposure data and hazard data are needed as inputs to run this software. Then InaSAFE can be used to forecast the impact of the hazard scenario to the exposure data. InaSAFE outputs include estimates of the number of people, buildings and roads are affected, list of minimum needs (rice and clean water), and response checklist. InaSAFE is developed by Indonesia's National Disaster Management Agency (BNPB) and the Australian Government, through the Australia-Indonesia Facility for Disaster Reduction (AIFDR), in partnership with the World Bank - Global Facility for Disaster Reduction and Recovery (GFDRR). This software has been used in many parts of Indonesia, including Padang, Maumere, Jakarta, and Slamet Mountain for emergency response and contingency planning.

  11. Safe Minimum Internal Temperature Chart

    Science.gov (United States)

    ... Internal Temperature Chart Safe steps in food handling, cooking, and storage are essential in preventing foodborne illness. You can't see, smell, or taste harmful bacteria that may cause illness. In every step of food preparation, follow the four guidelines to keep food safe: ...

  12. Mobile phone radiation induces mode-dependent DNA damage in a mouse spermatocyte-derived cell line: a protective role of melatonin.

    Science.gov (United States)

    Liu, Chuan; Gao, Peng; Xu, Shang-Cheng; Wang, Yuan; Chen, Chun-Hai; He, Min-Di; Yu, Zheng-Ping; Zhang, Lei; Zhou, Zhou

    2013-11-01

    To evaluate whether exposure to mobile phone radiation (MPR) can induce DNA damage in male germ cells. A mouse spermatocyte-derived GC-2 cell line was exposed to a commercial mobile phone handset once every 20 min in standby, listen, dialed or dialing modes for 24 h. DNA damage was determined using an alkaline comet assay. The levels of DNA damage were significantly increased following exposure to MPR in the listen, dialed and dialing modes. Moreover, there were significantly higher increases in the dialed and dialing modes than in the listen mode. Interestingly, these results were consistent with the radiation intensities of these modes. However, the DNA damage effects of MPR in the dialing mode were efficiently attenuated by melatonin pretreatment. These results regarding mode-dependent DNA damage have important implications for the safety of inappropriate mobile phone use by males of reproductive age and also suggest a simple preventive measure: Keeping mobile phones as far away from our body as possible, not only during conversations but during 'dialed' and 'dialing' operation modes. Since the 'dialed' mode is actually part of the standby mode, mobile phones should be kept at a safe distance from our body even during standby operation. Furthermore, the protective role of melatonin suggests that it may be a promising pharmacological candidate for preventing mobile phone use-related reproductive impairments.

  13. Steering teens safe: a randomized trial of a parent-based intervention to improve safe teen driving.

    Science.gov (United States)

    Peek-Asa, Corinne; Cavanaugh, Joseph E; Yang, Jingzhen; Chande, Vidya; Young, Tracy; Ramirez, Marizen

    2014-07-31

    Crashes are the leading cause of death for teens, and parent-based interventions are a promising approach. We assess the effectiveness of Steering Teens Safe, a parent-focused program to increase safe teen driving. Steering Teens Safe aimed to improve parental communication with teens about safe driving using motivational interviewing techniques in conjunction with 19 safe driving lessons. A randomized controlled trial involved 145 parent-teen dyads (70 intervention and 75 control). Intervention parents received a 45-minute session to learn the program with four follow-up phone sessions, a DVD, and a workbook. Control parents received a standard brochure about safe driving. Scores were developed to measure teen-reported quantity and quality of parental communication about safe driving. The main outcome measure was a previously validated Risky Driving Score reported by teens. Because the Score was highly skewed, a generalized linear model based on a gamma distribution was used for analysis. Intervention teens ranked their parent's success in talking about driving safety higher than control teens (p = 0.035) and reported that their parents talked about more topics (non-significant difference). The Risky Driving Score was 21% lower in intervention compared to control teens (85% CI = 0.60, 1.00). Interaction between communication quantity and the intervention was examined. Intervention teens who reported more successful communication had a 42% lower Risky Driving Score (95% CI = 0.37, 0.94) than control parents with less successful communication. This program had a positive although not strong effect, and it may hold the most promise in partnership with other programs, such as Driver's Education or Graduated Driver's License policies. ClinicalTrials.gov NCT01014923. Registered Nov. 16, 2009.

  14. Staying Safe in the Water

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dr. Julie Gilchrist, a pediatrician and medical epidemiologist from CDC’s Injury Center, talks about staying safe in the water. Tips are for all audiences, with a focus on preventing drownings and keeping children safe in and around the pool, lake, or ocean.

  15. Real Mission Profile Based Lifetime Estimation of Fuel-cell Power Converter

    DEFF Research Database (Denmark)

    Zhou, Dao; Wang, Huai; Blaabjerg, Frede

    2016-01-01

    . This paper describes a lifetime prediction method for the power semiconductors used in the power conditioning of a fuel cell based backup system, considering both the long-term standby mode and active operation mode. The annual ambient temperature profile is taken into account to estimate its impact...... on the degradation of MOSFETs during the standby mode. At the presence of power outages, the backup system is activated into the operation mode and the MOSFETs withstand additional thermal stresses due to power losses. A study case of a 1 kW backup system is presented with two annual mission profiles in Denmark...... and India, respectively. The ambient temperature, occurrence frequency of power outages, active operation time and power levels are considered for the lifetime prediction of the applied MOSFETs. Comparisons of the accumulated lifetime consumptions are performed between standby mode and operation mode...

  16. Safe biodegradable fluorescent particles

    Science.gov (United States)

    Martin, Sue I [Berkeley, CA; Fergenson, David P [Alamo, CA; Srivastava, Abneesh [Santa Clara, CA; Bogan, Michael J [Dublin, CA; Riot, Vincent J [Oakland, CA; Frank, Matthias [Oakland, CA

    2010-08-24

    A human-safe fluorescence particle that can be used for fluorescence detection instruments or act as a safe simulant for mimicking the fluorescence properties of microorganisms. The particle comprises a non-biological carrier and natural fluorophores encapsulated in the non-biological carrier. By doping biodegradable-polymer drug delivery microspheres with natural or synthetic fluorophores, the desired fluorescence can be attained or biological organisms can be simulated without the associated risks and logistical difficulties of live microorganisms.

  17. Safe Haven.

    Science.gov (United States)

    Bush, Gail

    2003-01-01

    Discusses school libraries as safe havens for teenagers and considers elements that foster that atmosphere, including the physical environment, lack of judgments, familiarity, leisure, and a welcoming nature. Focuses on the importance of relationships, and taking the time to listen to teens and encourage them. (LRW)

  18. METHODOLOGICAL APPROACHES TO ORGANIZATION OF SAFE INFORMATION AND EDUCATIONAL ENVIRONMENT OF THE UNIVERSITY

    Directory of Open Access Journals (Sweden)

    A. N. Privalov

    2017-01-01

    Full Text Available Introduction. One of the tendencies of modern higher education is the ubiquitous use of information and communication technologies. At the same time, the functioning of the electronic information and educational environment (IEE of the university should be based on the means of IEE and the condition of its information security.The aim of the research is conceptualization of a problem of the rational organization of the safe information and education environment of higher education institution wherein reliable protection of its infrastructure, the personal and unique information of a pupil and teacher and virtual space of their educational interaction is provided.Methodology and research methods. System-based approach is a key approach to organization of safe educational environment of the university. From the point of view of authors, personal-activity and functional approaches are expedient while designing and development of a safe IEE. Socio-historical and theoretical-methodological analysis, modeling, research and synthesis of experience of effective application of the systems approach in educational professional organizations are used.Results and scientific novelty. The concept «safe information educational environment of the university» is specified wherein the first word has to express a predominant quality of the system. Creating a safe information environment in educational professional organizations provides a convenient and safe educational environment in the process of professional training of university students. The components and directions for the organization of the safe IEE are highlighted. Practical recommendations for its design and successful functioning are given.Practical significance. The materials of the present research can be demanded by managers and administrative employees of educational organizations. 

  19. Strategies for safe motherhood.

    Science.gov (United States)

    Chatterjee, A

    1995-02-01

    The Safe Motherhood Initiative was launched in 1988 as a global effort to halve maternal mortality and morbidity by the year 2000. The program uses a combination of health and nonhealth strategies to emphasize the need for maternal health services, extend family planning services, and improve the status of women. The maternal mortality rate (per 100,000 live births) is 390 for the world, 20-30 for developed countries, 450 for developing countries, and 420 for Asia. This translates into 308,000 maternal deaths in Asia, of which 100,000 occur in India. The direct causes of maternal mortality include sepsis, hemorrhage, eclampsia, and ruptured uterus. Indirect causes occur when associated medical conditions, such as anemia and jaundice, are exacerbated by pregnancy. Underlying causes are ineffective health services, inadequate obstetric care, unregulated fertility, infections, illiteracy, early marriage, poverty, malnutrition, and ignorance. India's Child Survival and Safe Motherhood Program seeks to achieve immediate improvements by improving health care. Longterm improvements will occur as nutrition, income, education, and the status of women improve. Improvements in health care will occur in through the provision of 1) essential obstetric care for all women (which will be essentially designed for low-risk women), 2) early detection of complications during pregnancy and labor, and 3) emergency services. Services will be provided to pregnant women at their door by field staff, at a first referral hospital, perhaps at maternity villages where high risk cases can be housed in the latter part of their pregnancies, and through the continual accessibility of government vehicles. In addition, family planning services will be improved so that fertility regulation can have its expected beneficial effect on the maternal mortality rate. The professional health organizations in India will also play a vital role in the success of this effort to reduce maternal mortality.

  20. More than a Safe Space

    Science.gov (United States)

    Sadowski, Michael

    2016-01-01

    Over the past three decades, much of the conversation about LGBTQ students in schools has centered on safety--anti-bullying policies, the "safe space" of gay-straight alliances, and "safe zones" marked by rainbow-colored stickers on classroom doors. In this article, Michael Sadowski argues that it's time to move beyond safety…

  1. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  2. Managing Cassini Safe Mode Attitude at Saturn

    Science.gov (United States)

    Burk, Thomas A.

    2010-01-01

    The Cassini spacecraft was launched on October 15, 1997 and arrived at Saturn on June 30, 2004. It has performed detailed observations and remote sensing of Saturn, its rings, and its satellites since that time. In the event safe mode interrupts normal orbital operations, Cassini has flight software fault protection algorithms to detect, isolate, and recover to a thermally safe and commandable attitude and then wait for further instructions from the ground. But the Saturn environment is complex, and safety hazards change depending on where Cassini is in its orbital trajectory around Saturn. Selecting an appropriate safe mode attitude that insures safe operation in the Saturn environment, including keeping the star tracker field of view clear of bright bodies, while maintaining a quiescent, commandable attitude, is a significant challenge. This paper discusses the Cassini safe table management strategy and the key criteria that must be considered, especially during low altitude flybys of Titan, in deciding what spacecraft attitude should be used in the event of safe mode.

  3. Inherently safe light water reactors

    International Nuclear Information System (INIS)

    Ise, Takeharu

    1987-01-01

    Today's large nuclear power reactors of world-wise use have been designed based on the philosophy. It seems that recent less electricity demand rates, higher capital cost and the TMI accident let us acknowledge relative small and simplified nuclear plants with safer features, and that Chernobyl accident in 1983 underlines the needs of intrinsic and passive safety characteristics. In such background, several inherently safe reactor concepts have been presented abroad and domestically. First describing 'Can inherently safe reactors be designed,' then I introduce representative reactor concepts of inherently safe LWRs advocated abroad so far. All of these innovative reactors employ intrinsic and passive features in their design, as follows: (1) PIUS, an acronym for Process Inherent Ultimate Safety, or an integral PWR with passive heat sink and passive shutdown mechanism, advocated by ASEA-ATOM of Sweden. (2) MAP(Minimum Attention Plant), or a self-pressurized, natural circulation integral PWR, promoted by CE Inc. of the U.S. (3) TPS(TRIGA Power System), or a compact PWR with passive heat sink and inherent fuel characteristics of large prompt temperature coefficient, prompted by GA Technologies Inc. of the U.S. (4) PIUS-BWR, or an inherently safe BWR employing passively actuated fluid valves, in competition with PIUS, prompted by ORNL of the U.S. Then, I will describe the domestic trends in Japan and the innovative inherently safe LWRs presented domestically so far. (author)

  4. Dementia - keeping safe in the home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000031.htm Dementia - keeping safe in the home To use the ... make sure the homes of people who have dementia are safe for them. Safety Tips for the ...

  5. Safeguards Automated Facility Evaluation (SAFE) methodology

    International Nuclear Information System (INIS)

    Chapman, L.D.; Grady, L.M.; Bennett, H.A.; Sasser, D.W.; Engi, D.

    1978-01-01

    The SAFE procedure is an efficient method of evaluating the physical protection system of a nuclear facility. Since the algorithms used in SAFE for path generation and evaluation are analytical, many paths can be evaluated with a modest investment in computer time. SAFE is easy to use because the information required is well-defined and the interactive nature of this procedure lends itself to straightforward operation. The modular approach that has been taken allows other functionally equivalent modules to be substituted as they become available. The SAFE procedure has broad applications in the nuclear facility safeguards field as well as in the security field in general. Any fixed facility containing valuable materials or components to be protected from theft or sabotage could be analyzed using this same automated evaluation technique

  6. Nuclear hydrogen production and its safe handling

    International Nuclear Information System (INIS)

    Chung, Hongsuk; Paek, Seungwoo; Kim, Kwang-Rag; Ahn, Do-Hee; Lee, Minsoo; Chang, Jong Hwa

    2003-01-01

    An overview of the hydrogen related research presently undertaken at the Korea Atomic Energy Research Institute are presented. These encompass nuclear hydrogen production, hydrogen storage, and the safe handling of hydrogen, High temperature gas-cooled reactors can play a significant role, with respect to large-scale hydrogen production, if used as the provider of high temperature heat in fossil fuel conversion or thermochemical cycles. A variety of potential hydrogen production methods for high temperature gas-cooled reactors were analyzed. They are steam reforming of natural gas, thermochemical cycles, etc. The produced hydrogen should be stored safely. Titanium metal was tested primarily because its hydride has very low dissociation pressures at normal storage temperatures and a high capacity for hydrogen, it is easy to prepare and is non-reactive with air in the expected storage conditions. There could be a number of potential sources of hydrogen evolution risk in a nuclear hydrogen production facility. In order to reduce the deflagration detonation it is necessary to develop hydrogen control methods that are capable of dealing with the hydrogen release rate. A series of experiments were conducted to assess the catalytic recombination characteristics of hydrogen in an air stream using palladium catalysts. (author)

  7. Psychosocial aspect of safe operation in Japanese nuclear power plants

    International Nuclear Information System (INIS)

    Kuroda, Isao

    1988-01-01

    It is not easy to reveal the reasons of safe operation of N.P.P. because many complicated factors are interrelated. However, to clarify the effective factors of the recent safe operation of Japanese N.P.P. is the important thema of research to continue this condition and the more improved level. At present, the follwing factors can be pointed out; 1) Influential safety policy of regulatory structures. 2) Enthusiastic and careful company policy on N.P.P. safety. 3) Close and stable relationship of the industries with companies on research, training and maintenance. 4) Collaborated safety research among scientific facilities, companies and manufacturers. 5) Good organization and management for N.P.P. personnel. 6) Well organized training program in company and training facilities. 7) Highly motivated N.P.P. personnel with high educational background. 8) Company atmosphere on N.P.P. safety. 9) Public opinion on nuclear power safety. (author)

  8. Safe management of discussed sealed sources in Peru

    International Nuclear Information System (INIS)

    Mallaupoma, M.

    2000-01-01

    The future safe development of nuclear energy and progressive increasing use of sealed sources in medicine, research, industry and other fields in Peru, in the past years have determined the necessity to formulate and apply an Institutional policy to assure harmless and ecologically rational management of disused sealed sources in Peru. Some results of the studies, which served as a basis for design and construction of a facility for treatment, conditioning and storage of conditioned sealed sources are presented in this paper. The waste management system in Peru comprises operational and regulatory capabilities. Both of these activities are performed under a legislation. The Nuclear Research Center RACSO has a radioactive waste management department which is in charge of the management of disused sealed sources produced in the country. It is considered as a centralized waste processing and storage facility (WPSF). (author)

  9. Organising a safe space for navigating social-ecological transformations to sustainability.

    Science.gov (United States)

    Pereira, Laura; Karpouzoglou, Timothy; Doshi, Samir; Frantzeskaki, Niki

    2015-05-28

    The need for developing socially just living conditions for the world's growing population whilst keeping human societies within a 'safe operating space' has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and management regimes that guide human responses in areas such as urban ecology, public health, resource security (e.g., food, water, energy access), economic development and biodiversity conservation. However, such systemic transformations necessitate experimentation in public arenas of exchange and a deepening of processes that can widen multi-stakeholder learning. We argue that there is an emergent potential in bridging the sustainability transitions and resilience approaches to create new scientific capacity that can support large-scale social-ecological transformations (SETs) to sustainability globally, not just in the West. In this article, we elucidate a set of guiding principles for the design of a 'safe space' to encourage stronger interactions between these research areas and others that are relevant to the challenges faced. We envisage new opportunities for transdisciplinary collaboration that will develop an adaptive and evolving community of practice. In particular, we emphasise the great opportunity for engaging with the role of emerging economies in facilitating safe space experimentation.

  10. Breastfeeding FAQs: Safely Storing Breast Milk

    Science.gov (United States)

    ... Search English Español Breastfeeding FAQs: Safely Storing Breast Milk KidsHealth / For Parents / Breastfeeding FAQs: Safely Storing Breast ... may have. How do I store my breast milk? You can freeze and/or refrigerate your pumped ( ...

  11. Safe decommissioning of the Romanian VVR-S research reactor

    International Nuclear Information System (INIS)

    Garlea, C.; Garlea, I.; Kelerman, C.; Rodna, A.

    2002-01-01

    The VVR-S Romania research reactor was operated between 1957-1997, at 2 MW nominal power, for research and radioisotopical production. The detailed decommissioning plan was developed between 1995-1998, in the frame of the International Atomic Energy Agency Technical assistance project ROM/9/017. The proposed strategy agreed by the counterpart as well as international experts was stage 1. In 1997, an independent analysis performed by European Commission experts, in the frame of PHARE project PH04.1/1994 was dedicated to the 'Study of Soviet Design Research Reactors', had consolidated the development of the project emphasizing technical options of safe management for radioactive wastes and VVR-S spent fuel. The paper presents the main technical aspects as well as those of social impact, which lead to the establishment of strategy for safe management of decommissioning. Technical analysis of the VVR-S reactor and associated radwaste facilities (Radioactive Waste Treatment Plant - Magurele and National Repository Baita-Bihor) proved the possibility of the classical method utilization for dismantling of the facility and treatment-conditioning-disposal of the arrised wastes in safe conditions. The decommissioning plan at stage 2 has been developed based on radiological safety assessment, evaluation of radwaste inventory (removed as well as preserved on site), cost analysis and environmental impact. Technical data were provided by the R and D programme including neutron calculations and experiments, radiological characterizing (for facility and its influence area), seismic analysis and environmental balance during the operation and after shut down of the reactor. A special chapter is dedicated to regulatory issues concerning the development of decommissioning under nuclear safety. Based on the Fundamental Norms of Radiological Safety, the Regulatory Body defined the clearance levels and safety criteria for the process. The development of National Norms for the

  12. Removing Hair Safely

    Science.gov (United States)

    ... For Consumers Home For Consumers Consumer Updates Removing Hair Safely Share Tweet Linkedin Pin it More sharing ... related to common methods of hair removal. Laser Hair Removal In this method, a laser destroys hair ...

  13. Getting home safe and sound: occupational safety and health administration at 38.

    Science.gov (United States)

    Silverstein, Michael

    2008-03-01

    The Occupational Safety and Health Act of 1970 (OSHAct) declared that every worker is entitled to safe and healthful working conditions, and that employers are responsible for work being free from all recognized hazards. Thirty-eight years after these assurances, however, it is difficult to find anyone who believes the promise of the OSHAct has been met. The persistence of preventable, life-threatening hazards at work is a failure to keep a national promise. I review the history of the Occupational Safety and Health Administration and propose measures to better ensure that those who go to work every day return home safe and sound. These measures fall into 6 areas: leverage and accountability, safety and health systems, employee rights, equal protection, framing, and infrastructure.

  14. Power source with spark-safe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Tsesarenko, N P; Alekhin, A V

    1982-01-01

    The invention refers to the technique of electrical monitoring and control in systems operating in a spark-safe medium (for example, in coal mines). A more accurate area of application is mobile objects with autonomous source of electricity (mine diesel locomotives, battery electric locomotives etc.). The purpose of the invention is to simplify and to improve the reliability of the planned device, and also to expand the area of application for conditions when it is powered from an autonomous generator of direct voltage. This goal is achieved because the power source with spark-safe outlet (the source contains a thyristor of advance disconnection, connected by anode to the delimiting throttle, one outlet of which is connected to the capacitor included between the controlling electrode and the anode of the thyristor, and the capacitor is connected through the resistor parallel to the outlet clamps of the source, while the thyristor of emergency protection connected parallel to the inlet clamps of the power source) is additionally equipped with a current sensor, hercon, transistor key (included in series in the power circuit) and optron, whose emitter is connected parallel to the current sensor connected in series to the inlet of the power source, while the receiver of the optron is connected in a circuit for controlling the thyristor of emergency protection. Hercon is built into the core of the delimiting throttle and is connected to the circuit for controlling the transistor key.

  15. Developing Safe Schools Partnerships with Law Enforcement

    Science.gov (United States)

    Rosiak, John

    2009-01-01

    Safe schools are the concern of communities throughout the world. If a school is safe, and if children feel safe, students "are better able to learn. But what are the steps to make" this happen? First, it is important to understand the problem: What are the threats to school safety? These include crime-related behaviors that find their way to…

  16. Study on the Post-Fire Safe-Shutdown Analysis for CANDU NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Hwan; Kim, Yun Jung; Park, Mun Hee [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The purpose of this paper is to study a method of the Post-Fire Safe-Shutdown Analysis in order to apply to CANDU NPPs when one group of the Safety Structures, Systems and Components(SCCs) is failed by Fire. The purpose of Fire Protection is prevention, suppression of the fire and mitigation of the effect on the Nuclear Safety. When fire takes place at the Nuclear Power Plants(NPPs), the reactor should achieve and maintain safe shut-down condition and minimize radioactive material release to an environment. The purpose of the Post-Fire SSA process is an evaluation process during a fire at NPPs. At this study, the process was conceptually adopted for control room complex of CANDU NPPs. The Core Damage Frequency of the Reactor will be evaluated more accurately if the SSA is adopted adequately at a fire.

  17. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Ha, Che-Wung; Lee, Do-Hwan

    2015-01-01

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources

  18. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Che-Wung; Lee, Do-Hwan [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources.

  19. Safe use of ionizing radiations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    Based on the ''Code of Practice for the protection of persons against ionizing radiations arising from medical and dental use'' (CIS 74-423), this handbook shows how hospital staff can avoid exposing themselves and others to these hazards. It is designed particularly for junior and student nurses. Contents: ionizing radiations, their types and characteristics; their uses and dangers; basic principles in their safe use; safe use in practice; explanation of terms.

  20. Staying Safe in the Water

    Centers for Disease Control (CDC) Podcasts

    2008-05-15

    In this podcast, Dr. Julie Gilchrist, a pediatrician and medical epidemiologist from CDC’s Injury Center, talks about staying safe in the water. Tips are for all audiences, with a focus on preventing drownings and keeping children safe in and around the pool, lake, or ocean.  Created: 5/15/2008 by National Center for Injury Prevention and Control (NCIPC).   Date Released: 5/19/2008.

  1. Standby after the Chernobyl accident

    International Nuclear Information System (INIS)

    1987-09-01

    The report is an investigation concerning strandby and actions by SKI (Swedish Nuclear Power Inspectorate) and SSI (National Institute of Radiation Protection) due to the Chernobyl reactor accident. It consists of a final report and two appendices. The final report is divided into two parts: 'I: Facts' and 'II: Analyzes'. 'Facts': The Swedish model for information: radio, press. Basic knowledge about ionizing radiation in the society. Resources for information. Need for information. Message forms for information. Announcements from the authorities in TV, radio, press, meeting, advertisements. Statements concerning the reactor accident and its consequences in Swedish mass media. How did the public recieve the information? 'Analyzis': Information responsibilities and policies. SSI information activities concerning radiologic accidents, conditions, methods and resources. Ditto for SKI, Swedish National Food Administration and the National Board of Agriculture. Appendix I: Information from authorities in the press three weeks after the Chernobyl accident: The material and the methods. The acute phase, the adoptation phase, the extension of the persective. What is said about the authorities in connection with Chernobyl? Appendix II: The fallout from Chernobyl, the authorities and the media coverage: The nationwide, regional and local coverage from radio and television. Ditto from the press. Topic and problem areas in reporting. Instructions from the authorities in media. Contribution in the media from people representing the authorities. Fallout in a chronologic perspective. (L.F.)

  2. A study on the boron injection initiation temperature curve of BWR

    International Nuclear Information System (INIS)

    Wang, S.-J.; Chien, C.-S.; Fann, S.-Y.; Chiang, S.-C.

    2007-01-01

    Boron injection initiation temperature (BIIT) provides important information for the safe shutdown of the reactor using boron injection system during anticipated transient without scram (ATWS). The purpose of this paper is to study BIIT curve of boiling water reactor owners' group (BWROG). The unreasonable and non-conservative parts of BIIT are pointed out and suggested modifications are made. The starting reactor power of BIIT is increased in order to meet the actual application. The lower limit of suppression pool temperature of BIIT is revised for conservative operation during ATWS conditions. Analysis of the effects of maximum temperature capacity of the suppression chamber and concentration of boron in standby liquid control tank shows that BIIT is decreased by adopting a more conservative value of maximum temperature capacity of the suppression chamber. Consequently, early boron injection is anticipated. For system with automatic boron injection system, BIIT is not required

  3. Organising a safe space for navigating social-ecological transformations to sustainability

    OpenAIRE

    Pereira, L.; Karpouzoglou, T.D.; Doshi, S.; Frantzeskaki, N.

    2015-01-01

    textabstractThe need for developing socially just living conditions for the world’s growing population whilst keeping human societies within a ‘safe operating space’ has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and management regimes that guide human responses in areas such as urban ecology, public health, resource security (e.g., food, water, energy access), economic development and biodiversity conservation. Howeve...

  4. Recurrent Urinary Tract Infections and Related Conditions (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Recurrent Urinary Tract Infections and Related Conditions KidsHealth / For Parents / Recurrent Urinary Tract Infections and Related Conditions What's in this article? ...

  5. A Compact Safe Cold-Start (CS2) System for Scramjets using Dilute Triethylaluminum Fuel Mixtures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the cold-start requirements of scramjet engines by developing a safe, energy-dense, and low volume hydrocarbon fuel conditioning system based...

  6. An Automated Safe-to-Mate (ASTM) Tester

    Science.gov (United States)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  7. Vitamin D Status, Bone Mineral Density and Mental Health in Young Australian Women: The Safe-D Study.

    Science.gov (United States)

    Callegari, Emma T; Reavley, Nicola; Garland, Suzanne M; Gorelik, Alexandra; Wark, John D

    2015-11-17

    Vitamin D deficiency has been associated with both poor bone health and mental ill-health. More recently, a number of studies have found individuals with depressive symptoms tend to have reduced bone mineral density. To explore the interrelationships between vitamin D status, bone mineral density and mental-ill health we are assessing a range of clinical, behavioural and lifestyle factors in young women (Part A of the Safe-D study). Part A of the Safe-D study is a cross-sectional study aiming to recruit 468 young females aged 16-25 years living in Victoria, Australia, through Facebook advertising. Participants are required to complete an extensive, online questionnaire, wear an ultra-violet dosimeter for 14 consecutive days and attend a study site visit. Outcome measures include areal bone mineral measures at the lumbar spine, total hip and whole body, as well as soft tissue composition using dual energy x-ray absorptiometry. Trabecular and cortical volumetric bone density at the tibia is measured using peripheral quantitative computed tomography. Other tests include serum 25-hydroxyvitamin D, serum biochemistry and a range of health markers. Details of mood disorder/s and depressive and anxiety symptoms are obtained by self-report. Cutaneous melanin density is measured by spectrophotometry. The findings of this cross-sectional study will have implications for health promotion in young women and for clinical care of those with vitamin D deficiency and/or mental ill-health. Optimising both vitamin D status and mental health may protect against poor bone health and fractures in later life. Significance for public healthVitamin D deficiency, depression and osteoporosis are all major public health issues. Vitamin D deficiency has been associated with both reduced bone mineral density and depressive symptoms. Moreover, cohort studies have found that subjects with depression have lower bone mineral density when compared to healthy controls. Early adulthood is a critical

  8. USING THE SAFE SYSTEM APPROACH TO KEEP OLDER DRIVERS SAFELY MOBILE

    Directory of Open Access Journals (Sweden)

    Jim LANGFORD

    2006-01-01

    Full Text Available In 2003, Australian road transport jurisdictions collectively accepted that the greatest road safety gains would be achieved through adopting a Safe System approach, derived from Sweden's Vision Zero and the Netherlands' Sustainable Safety strategies. A key objective of all three approaches is to manage vehicles, the road infrastructure, speeds, road users and the interactions between these components, to ensure that in the event of crashes, crash energies will remain at levels that minimize the probability of death and serious injury. Older drivers pose a particular challenge to the Safe System approach, given particularly their greater physical frailty, their driving patterns and for some at least, their reduced fitness to drive. This paper has analyzed the so-called ‘older driver problem’ and identified a number of key factors underpinning their crash levels, for which countermeasures can be identified and implemented within a Safe System framework. The recommended countermeasures consist of: (1 safer roads, through a series of design improvements particularly governing urban intersections; (2 safer vehicles, through both the promotion of crashworthiness as a critical consideration when purchasing a vehicle and the wide use of developed and developing ITS technologies; (3 safer speeds especially at intersections; and (4 safer road users, through both improved assessment procedures to identify the minority of older drivers with reduced fitness to drive and educational efforts to encourage safer driving habits particularly but not only through self-regulation.

  9. "From safe source to safe sink" development of colorimetric assay for gabapentin in bulk drug and capsules using naturally derived genipin.

    Science.gov (United States)

    Winotapun, Weerapath; Kongpakwattana, Khachen; Dejpittayanunt, Sirirat; Pathomcharoensukchai, Suwaparp; Suksaran, Udomluck; Nuntharatanapong, Nopparat; Rojanarata, Theerasak

    2012-09-15

    A novel colorimetric assay for gabapentin in bulk drug and capsules has been developed via a safety-and-sustainability concerning concept. The method relied on the reaction of primary amino group of drug with non-toxic and eco-friendly genipin in totally aqueous medium to form the blue product which was subsequently measured by visible spectrophotometry at 590 nm. Under the optimized conditions, Beer's law was obeyed in the concentration range of 0.15-0.50 mM (r(2)=0.9998). It was accurate, precise and insensitive to the interferences from all related compounds specified in the United States Pharmacopeia as well as commonly used excipients. Furthermore, it gave the assay results in agreement with the pharmacopeial chromatographic method. Owing to the environmental concern and responsibility, a fast and facile method was also proposed for the treatment of waste generated from the assay based on the decoloration by using gypsum as a cheap and commonly available adsorbent. After the treatment, more than 95% of the initial blue product was removed from the waste solution and the treated waste was proven to be safe for aquatic organisms, as studied in brine shrimp and guppy fishes. Therefore, this work not only reports for the first time the application of naturally derived genipin to drug analysis, but also presents a new and contemporary paradigm that illustrates the fully benign-by-design development of the analytical methodologies in the era of Green Chemistry, starting from the safe source of reagents toward the safe sink when waste is released into the environment. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Feeling safe during an inpatient hospitalization: a concept analysis.

    Science.gov (United States)

    Mollon, Deene

    2014-08-01

    This paper aims to explore the critical attributes of the concept feeling safe. The safe delivery of care is a high priority; however; it is not really known what it means to the patient to 'feel safe' during an inpatient hospitalization. This analysis explores the topic of safety from the patient's perspective. Concept analysis. The data bases of CINAHL, Medline, PsychInfo and Google Scholar for the years 1995-2012 were searched using the terms safe and feeling safe. The eight-step concept analysis method of Walker and Avant was used to analyse the concept of feeling safe. Uses and defining attributes, as well as identified antecedents, consequences and empirical referents, are presented. Case examples are provided to assist in the understanding of defining attributes. Feeling safe is defined as an emotional state where perceptions of care contribute to a sense of security and freedom from harm. Four attributes were identified: trust, cared for, presence and knowledge. Relationship, environment and suffering are the antecedents of feeling safe, while control, hope and relaxed or calm are the consequences. Empirical referents and early development of a theory of feeling safe are explored. This analysis begins the work of synthesizing qualitative research already completed around the concept of feeling safe by defining the key attributes of the concept. Support for the importance of developing patient-centred models of care and creating positive environments where patients receive high-quality care and feel safe is provided. © 2014 John Wiley & Sons Ltd.

  11. Creating Safe Spaces for Music Learning

    Science.gov (United States)

    Hendricks, Karin S.; Smith, Tawnya D.; Stanuch, Jennifer

    2014-01-01

    This article offers a practical model for fostering emotionally safe learning environments that instill in music students a positive sense of self-belief, freedom, and purpose. The authors examine the implications for music educators of creating effective learning environments and present recommendations for creating a safe space for learning,…

  12. Keeping Food Safe

    Centers for Disease Control (CDC) Podcasts

    2009-05-27

    This CDC Kidtastics podcast discusses things kids and parents can do to help prevent illness by keeping food safe.  Created: 5/27/2009 by National Center for Zoonotic, Vector-Borne, and Enteric Diseases (NCZVED).   Date Released: 5/27/2009.

  13. Organising a Safe Space for Navigating Social-Ecological Transformations to Sustainability

    Directory of Open Access Journals (Sweden)

    Laura Pereira

    2015-05-01

    Full Text Available The need for developing socially just living conditions for the world’s growing population whilst keeping human societies within a ‘safe operating space’ has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and management regimes that guide human responses in areas such as urban ecology, public health, resource security (e.g., food, water, energy access, economic development and biodiversity conservation. However, such systemic transformations necessitate experimentation in public arenas of exchange and a deepening of processes that can widen multi-stakeholder learning. We argue that there is an emergent potential in bridging the sustainability transitions and resilience approaches to create new scientific capacity that can support large-scale social-ecological transformations (SETs to sustainability globally, not just in the West. In this article, we elucidate a set of guiding principles for the design of a ‘safe space’ to encourage stronger interactions between these research areas and others that are relevant to the challenges faced. We envisage new opportunities for transdisciplinary collaboration that will develop an adaptive and evolving community of practice. In particular, we emphasise the great opportunity for engaging with the role of emerging economies in facilitating safe space experimentation.

  14. Organising a Safe Space for Navigating Social-Ecological Transformations to Sustainability

    Science.gov (United States)

    Pereira, Laura; Karpouzoglou, Timothy; Doshi, Samir; Frantzeskaki, Niki

    2015-01-01

    The need for developing socially just living conditions for the world’s growing population whilst keeping human societies within a ‘safe operating space’ has become a modern imperative. This requires transformative changes in the dominant social norms, behaviours, governance and management regimes that guide human responses in areas such as urban ecology, public health, resource security (e.g., food, water, energy access), economic development and biodiversity conservation. However, such systemic transformations necessitate experimentation in public arenas of exchange and a deepening of processes that can widen multi-stakeholder learning. We argue that there is an emergent potential in bridging the sustainability transitions and resilience approaches to create new scientific capacity that can support large-scale social-ecological transformations (SETs) to sustainability globally, not just in the West. In this article, we elucidate a set of guiding principles for the design of a ‘safe space’ to encourage stronger interactions between these research areas and others that are relevant to the challenges faced. We envisage new opportunities for transdisciplinary collaboration that will develop an adaptive and evolving community of practice. In particular, we emphasise the great opportunity for engaging with the role of emerging economies in facilitating safe space experimentation. PMID:26030471

  15. Plutonium safe handling

    International Nuclear Information System (INIS)

    Tvehlov, Yu.

    2000-01-01

    The abstract, prepared on the basis of materials of the IAEA new leadership on the plutonium safe handling and its storage (the publication no. 9 in the Safety Reports Series), aimed at presenting internationally acknowledged criteria on the radiation danger evaluation and summarizing the experience in the safe management of great quantities of plutonium, accumulated in the nuclear states, is presented. The data on the weapon-class and civil plutonium, the degree of its danger, the measures for provision of its safety, including the data on accident radiation consequences with the fission number 10 18 , are presented. The recommendations, making it possible to eliminate the super- criticality danger, as well as ignition and explosion, to maintain the tightness of the facility, aimed at excluding the radioactive contamination and the possibility of internal irradiation, to provide for the plutonium security, physical protection and to reduce irradiation are given [ru

  16. 24 CFR 902.30 - Financial condition assessment.

    Science.gov (United States)

    2010-04-01

    ... financial condition of a PHA for the purpose of evaluating whether it has sufficient financial resources and... is decent, safe, sanitary and in good repair. (b) Financial reporting standards. A PHA's financial... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Financial condition assessment. 902...

  17. Safe injection practice among health care workers, Gharbiya, Egypt.

    Science.gov (United States)

    Ismail, Nanees A; Aboul Ftouh, Aisha M; El Shoubary, Waleed H

    2005-01-01

    A cross-sectional study was conducted in 25 health care facilities in Gharbiya governorate to assess safe injection practices among health care workers (HCWs). Two questionnaires, one to collect information about administrative issues related to safe injection and the other to collect data about giving injections, exposure to needle stick injuries, hepatitis B vaccination status and safe injection training. Practices of injections were observed using a standardized checklist. The study revealed that there was lack of both national and local infection control policies and lack of most of the supplies needed for safe injection practices. Many safe practices were infrequent as proper needle manipulation before disposal (41%), safe needle disposal (47.5%), reuse of used syringe & needle (13.2%) and safe syringe disposal (0%). Exposure to needle stick injuries were common among the interviewed HCWs (66.2%) and hand washing was the common post exposure prophylaxis measure (63.4%). Only 11.3% of HCWs had full course hepatitis B vaccination. Infection control -including safe injections- training programs should be afforded to all HCWs.

  18. SafeNet: a methodology for integrating general-purpose unsafe devices in safe-robot rehabilitation systems.

    Science.gov (United States)

    Vicentini, Federico; Pedrocchi, Nicola; Malosio, Matteo; Molinari Tosatti, Lorenzo

    2014-09-01

    Robot-assisted neurorehabilitation often involves networked systems of sensors ("sensory rooms") and powerful devices in physical interaction with weak users. Safety is unquestionably a primary concern. Some lightweight robot platforms and devices designed on purpose include safety properties using redundant sensors or intrinsic safety design (e.g. compliance and backdrivability, limited exchange of energy). Nonetheless, the entire "sensory room" shall be required to be fail-safe and safely monitored as a system at large. Yet, sensor capabilities and control algorithms used in functional therapies require, in general, frequent updates or re-configurations, making a safety-grade release of such devices hardly sustainable in cost-effectiveness and development time. As such, promising integrated platforms for human-in-the-loop therapies could not find clinical application and manufacturing support because of lacking in the maintenance of global fail-safe properties. Under the general context of cross-machinery safety standards, the paper presents a methodology called SafeNet for helping in extending the safety rate of Human Robot Interaction (HRI) systems using unsafe components, including sensors and controllers. SafeNet considers, in fact, the robotic system as a device at large and applies the principles of functional safety (as in ISO 13489-1) through a set of architectural procedures and implementation rules. The enabled capability of monitoring a network of unsafe devices through redundant computational nodes, allows the usage of any custom sensors and algorithms, usually planned and assembled at therapy planning-time rather than at platform design-time. A case study is presented with an actual implementation of the proposed methodology. A specific architectural solution is applied to an example of robot-assisted upper-limb rehabilitation with online motion tracking. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Nurses' clinical reasoning practices that support safe medication administration: An integrative review of the literature.

    Science.gov (United States)

    Rohde, Emily; Domm, Elizabeth

    2018-02-01

    To review the current literature about nurses' clinical reasoning practices that support safe medication administration. The literature about medication administration frequently focuses on avoiding medication errors. Nurses' clinical reasoning used during medication administration to maintain medication safety receives less attention in the literature. As healthcare professionals, nurses work closely with patients, assessing and intervening to promote mediation safety prior to, during and after medication administration. They also provide discharge teaching about using medication safely. Nurses' clinical reasoning and practices that support medication safety are often invisible when the focus is medication errors avoidance. An integrative literature review was guided by Whittemore and Knafl's (Journal of Advanced Nursing, 5, 2005 and 546) five-stage review of the 11 articles that met review criteria. This review is modelled after Gaffney et al.'s (Journal of Clinical Nursing, 25, 2016 and 906) integrative review on medical error recovery. Health databases were accessed and systematically searched for research reporting nurses' clinical reasoning practices that supported safe medication administration. The level and quality of evidence of the included research articles were assessed using The Johns Hopkins Nursing Evidence-Based Practice Rating Scale©. Nurses have a central role in safe medication administration, including but not limited to risk awareness about the potential for medication errors. Nurses assess patients and their medication and use knowledge and clinical reasoning to administer medication safely. Results indicated nurses' use of clinical reasoning to maintain safe medication administration was inadequately articulated in 10 of 11 studies reviewed. Nurses are primarily responsible for safe medication administration. Nurses draw from their foundational knowledge of patient conditions and organisational processes and use clinical reasoning that

  20. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    International Nuclear Information System (INIS)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship 'Mutsu'. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  1. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship `Mutsu`. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  2. Implicit attitudes towards risky and safe driving

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne; Sømhovd, Mikael Julius; Møller, Mette

    ; further, self-reports of the intention to drive safely (or not) are socially sensitive. Therefore, we examined automatic preferences towards safe and risky driving with a Go/No-go Association Task (GNAT). The results suggest that (1) implicit attitudes towards driving behavior can be measured reliably...... with the GNAT; (2) implicit attitudes towards safe driving versus towards risky driving may be separable constructs. We propose that research on driving behavior may benefit from routinely including measures of implicit cognition. A practical advantage is a lesser susceptibility to social desirability biases......, compared to self-report methods. Pending replication in future research, the apparent dissociation between implicit attitudes towards safe versus risky driving that we observed may contribute to a greater theoretical understanding of the causes of unsafe and risky driving behavior....

  3. Prospects for inherently safe reactors

    International Nuclear Information System (INIS)

    Barkenbus, J.N.

    1988-01-01

    Public fears over nuclear safety have led some within the nuclear community to investigate the possibility of producing inherently safe nuclear reactors; that is, reactors that are transparently incapable of producing a core melt. While several promising designs of such reactors have been produced, support for large-scale research and development efforts has not been forthcoming. The prospects for commercialization of inherently safe reactors, therefore, are problematic; possible events such as further nuclear reactor accidents and superpower summits, could alter the present situation significantly. (author)

  4. Aflatoxins & Safe Storage

    Directory of Open Access Journals (Sweden)

    Philippe eVillers

    2014-04-01

    Full Text Available The paper examines both field experience and research on the prevention of the exponential growth of aflatoxins during multi-month post harvest storage in hot, humid countries. The approach described is the application of modern safe storage methods using flexible, Ultra Hermetic™ structures that create an unbreatheable atmosphere through insect and microorganism respiration alone, without use of chemicals, fumigants, or pumps. Laboratory and field data are cited and specific examples are given describing the uses of Ultra Hermetic storage to prevent the growth of aflatoxins with their significant public health consequences. Also discussed is the presently limited quantitative information on the relative occurrence of excessive levels of aflatoxin (>20 ppb before versus after multi-month storage of such crops as maize, rice and peanuts when under high humidity, high temperature conditions and, consequently, the need for further research to determine the frequency at which excessive aflatoxin levels are reached in the field versus after months of post-harvest storage. The significant work being done to reduce aflatoxin levels in the field is mentioned, as well as its probable implications on post harvest storage. Also described is why, with some crops such as peanuts, using Ultra Hermetic storage may require injection of carbon dioxide or use of an oxygen absorber as an accelerant. The case of peanuts is discussed and experimental data is described.

  5. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Dolphin-safe labeling standards. 216.91... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of... include on the label of those products the term “dolphin-safe” or any other term or symbol that claims or...

  6. Medications: Using Them Safely

    Science.gov (United States)

    ... to Safely Give Ibuprofen Childproofing and Preventing Household Accidents Medicines for Diabetes Complementary and Alternative Medicine How Do Pain Relievers Work? What Medicines Are and What They Do Medicines ...

  7. Implementation of Safe-by-Design for Nanomaterial Development and Safe Innovation: Why We Need a Comprehensive Approach.

    Science.gov (United States)

    Kraegeloh, Annette; Suarez-Merino, Blanca; Sluijters, Teun; Micheletti, Christian

    2018-04-14

    Manufactured nanomaterials (MNMs) are regarded as key components of innovations in various fields with high potential impact (e.g., energy generation and storage, electronics, photonics, diagnostics, theranostics, or drug delivery agents). Widespread use of MNMs raises concerns about their safety for humans and the environment, possibly limiting the impact of the nanotechnology-based innovation. The development of safe MNMs and nanoproducts has to result in a safe as well as functional material or product. Its safe use, and disposal at the end of its life cycle must be taken into account too. However, not all MNMs are similarly useful for all applications, some might bear a higher hazard potential than others, and use scenarios could lead to different exposure probabilities. To improve both safety and efficacy of nanotechnology, we think that a new proactive approach is necessary, based on pre-regulatory safety assessment and dialogue between stakeholders. On the basis of the work carried out in different European Union (EU) initiatives, developing and integrating MNMs Safe-by-Design and Trusted Environments (NANoREG, ProSafe, and NanoReg2), we present our point of view here. This concept, when fully developed, will allow for cost effective industrial innovation, and an exchange of key information between regulators and innovators. Regulators are thus informed about incoming innovations in good time, supporting a proactive regulatory action. The final goal is to contribute to the nanotechnology governance, having faster, cheaper, effective, and safer nano-products on the market.

  8. Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

    Science.gov (United States)

    Burns, Bradley M.; Blalock, Norman N.

    2010-01-01

    A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the

  9. FY 2000 report on the results of the development of the stand-by consumption power reduction technology. R and D of the stand-by consumption power reduction technology in relation to machine tools; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kosaku kiki ni kanrensuru taikiji shohi denryoku sakugen gijutsu no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    In relation to machine tools, a method was studied for reducing consumption power at the time of standing-by, keeping the present processing accuracy, processing efficiency and operability, and the results of the study were as follows. As to the chip conveyer, the stand-by consumption power was reduced by approximately 75% by reducing the motor capacity by reviewing the effective operation method and the structure. Concerning the mist collector, a reduction of approximately 85% was confirmed by adopting the efficient operation method and high-efficient motor. Relating to the oil controller, an experiment was made on the frame thermal circulation system and the self-forced air cooling system. In terms of the rise in temperature, the controller is lower than the existing one, but it was found out that the consumption power could be reduced by about 14% and about 98%, respectively. About the coolant pump, the optimum inclination angle/necessary minimum flow rate of oil pan were confirmed, and a reduction of 47% was confirmed. As to the hydraulic pump, study was made of a method to substitute other power source for oil pressure and the intermittent operation of hydraulic unit, and effects of each were confirmed. Further studies were made of the control disc, reduction in air consumption, etc. (NEDO)

  10. Which non-technical skills do junior doctors require to prescribe safely? A systematic review.

    Science.gov (United States)

    Dearden, Effie; Mellanby, Edward; Cameron, Helen; Harden, Jeni

    2015-12-01

    Prescribing errors are a major source of avoidable morbidity and mortality. Junior doctors write most in-hospital prescriptions and are the least experienced members of the healthcare team. This puts them at high risk of error and makes them attractive targets for interventions to improve prescription safety. Error analysis has shown a background of complex environments with multiple contributory conditions. Similar conditions in other high risk industries, such as aviation, have led to an increased understanding of so-called human factors and the use of non-technical skills (NTS) training to try to reduce error. To date no research has examined the NTS required for safe prescribing. The aim of this review was to develop a prototype NTS taxonomy for safe prescribing, by junior doctors, in hospital settings. A systematic search identified 14 studies analyzing prescribing behaviours and errors by junior doctors. Framework analysis was used to extract data from the studies and identify behaviours related to categories of NTS that might be relevant to safe and effective prescribing performance by junior doctors. Categories were derived from existing literature and inductively from the data. A prototype taxonomy of relevant categories (situational awareness, decision making, communication and team working, and task management) and elements was constructed. This prototype will form the basis of future work to create a tool that can be used for training and assessment of medical students and junior doctors to reduce prescribing error in the future. © 2015 The British Pharmacological Society.

  11. Safe havens in Europe: Switzerland and the ten dwarfs

    Directory of Open Access Journals (Sweden)

    Martin Paldam

    2013-12-01

    Full Text Available Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11countries are richer than their large neighbors. It is shown that causality is from small to safe haven towealth, and that theoretically equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds.

  12. Safe and Liquid Mortgage Bonds

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens; Gyntelberg, Jacob; Lund, Jesper

    This paper shows that strict match pass-through funding of covered bonds provides safe and liquid mortgage bonds. Despite a 30% drop in house prices during the 2008 global crisis Danish mortgage bonds remained as liquid as most European government bonds. The Danish pass-through system effectively...... eliminates credit risk from the investor's perspective. Similar to other safe bonds, funding liquidity becomes the main driver of mortgage bond liquidity and this creates commonality in liquidity across markets and countries. These findings have implications for how to design a robust mortgage bond system...

  13. Implementation of an Improved Safe Operating Envelope

    International Nuclear Information System (INIS)

    Prime, Robyn; McIntyre, Mark; Reeves, David

    2008-01-01

    This paper is a continuation of the paper presented at IYNC 2004 on 'The Definition of a Safe Operating Envelope'. The current paper concentrates on the implementation process of the Safe Operating Envelope employed at the Point Lepreau Generating Station. (authors)

  14. Implementation of an Improved Safe Operating Envelope

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Robyn; McIntyre, Mark [NB Power Nuclear, P.O. Box 600, Lepreau, NB (Canada); Reeves, David [Atlantic Nuclear Services Ltd., PO Box 1268 Fredericton, NB (Canada)

    2008-07-01

    This paper is a continuation of the paper presented at IYNC 2004 on 'The Definition of a Safe Operating Envelope'. The current paper concentrates on the implementation process of the Safe Operating Envelope employed at the Point Lepreau Generating Station. (authors)

  15. From Safe Systems to Patient Safety

    DEFF Research Database (Denmark)

    Aarts, J.; Nøhr, C.

    2010-01-01

    for the third conference with the theme: The ability to design, implement and evaluate safe, useable and effective systems within complex health care organizations. The theme for this conference was "Designing and Implementing Health IT: from safe systems to patient safety". The contributions have reflected...... and implementation of safe systems and thus contribute to the agenda of patient safety? The contributions demonstrate how the health informatics community has contributed to the performance of significant research and to translating research findings to develop health care delivery and improve patient safety......This volume presents the papers from the fourth International Conference on Information Technology in Health Care: Socio-technical Approaches held in Aalborg, Denmark in June 2010. In 2001 the first conference was held in Rotterdam, The Netherlands with the theme: Sociotechnical' approaches...

  16. The first safe country

    Directory of Open Access Journals (Sweden)

    Raffaela Puggioni

    2012-06-01

    Full Text Available The Dublin II Regulation makes the first safe country of refuge solelyresponsible for refugees and asylum seekers. In the case of Italy, thefirst responsible country has not been acting responsibly.

  17. Karate: Keep It Safe.

    Science.gov (United States)

    Jordan, David

    1981-01-01

    Safety guidelines for each phase of a karate practice session are presented to provide an accident-free and safe environment for teaching karate in a physical education or traditional karate training program. (JMF)

  18. Validity and reliability of a self-administered foot evaluation questionnaire (SAFE-Q).

    Science.gov (United States)

    Niki, Hisateru; Tatsunami, Shinobu; Haraguchi, Naoki; Aoki, Takafumi; Okuda, Ryuzo; Suda, Yasunori; Takao, Masato; Tanaka, Yasuhito

    2013-03-01

    The Japanese Society for Surgery of the Foot (JSSF) is developing a QOL questionnaire instrument for use in pathological conditions related to the foot and ankle. The main body of the outcome instrument (the Self-Administered Foot Evaluation Questionnaire, SAFE-Q version 2) consists of 34 questionnaire items, which provide five subscale scores (1: Pain and Pain-Related; 2: Physical Functioning and Daily Living; 3: Social Functioning; 4: Shoe-Related; and 5: General Health and Well-Being). In addition, the instrument has nine optional questionnaire items that provide a Sports Activity subscale score. The purpose of this study was to evaluate the test-retest reliability of the SAFE-Q. Version 2 of the SAFE-Q was administered to 876 patients and 491 non-patients, and the test-retest reliability was evaluated for 131 patients. In addition, the SF-36 questionnaire and the JSSF Scale scoring form were administered to all of the participants. Subscale scores were scaled such that the final sum of scores ranged between zero (least healthy) to 100 (healthiest). The intraclass correlation coefficients were larger than 0.7 for all of the scores. The means of the five subscale scores were between 60 and 75. The five subscales easily separated patients from non-patients. The coefficients for the correlations of the subscale scores with the scores on the JSSF Scale and the SF-36 subscales were all highly statistically significantly greater than zero (p valid and reliable. In the future, it will be beneficial to test the responsiveness of the SAFE-Q.

  19. Prepare to protect: Operating and maintaining a tornado safe room.

    Science.gov (United States)

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  20. Raising the Profile of Energy Efficiency in China

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Reducing standby power use in China. How much does China stand to gain from greater energy efficiency? The example of improved standby power efficiency in household appliances provides a useful indicator. IEA analysis projects that eight or nine 1-GW power plants could be struck off Chinas list of immediate capacity needs for the period to 2020 if energy-efficient standby devices were vigorously promoted. This impressive finding emerges from this paper. The paper reviews experience with tackling standby power consumption in OECD countries and models implementation of similar action in China and Shanghai. Its scenarios quantify the significant potential gains from standby power conservation campaigns and mandatory regulations.

  1. Source term aspects associated with future PWR containment systems

    International Nuclear Information System (INIS)

    Kuczera, B.; Kebler, G.; Ehrhardt, J.; Scholtyssek, W.

    1994-01-01

    The overall objective of reactor safety is to protect the population against dangerous releases of radioactive materials from nuclear power plants. In context with a reinforcement of the defense-in-depth strategy the common safety requirements on future nuclear power plants converge in the objective that these plants should be so safe that even in case of a severe accident there will be no need of off-site emergency actions such as an evacuation or resettlement of the population from the vicinity of a nuclear power plant. It is shown by the example of a future 1400 MWe pressurized water reactor (PWR) plant that this goal can be attained in principle by providing a double containment with the annulus vented via an appropriate emergency standby filter. Within the framework of severe accident consequence mitigation a set of parameters for accident conditions and emergency filter efficiencies is elaborated under which the German lower levels of intervention for evacuation are not attained. (author). 10 refs., 3 tabs., 5 figs

  2. Safe actinide disposition in molten salt reactors

    International Nuclear Information System (INIS)

    Gat, U.

    1997-01-01

    Safe molten salt reactors (MSR) can readily accommodate the burning of all fissile actinides. Only minor compromises associated with plutonium are required. The MSRs can dispose safely of actinides and long lived isotopes to result in safer and simpler waste. Disposing of actinides in MSRs does increase the source term of a safety optimized MSR. It is concluded that the burning and transmutation of actinides in MSRs can be done in a safe manner. Development is needed for the processing to handle and separate the actinides. Calculations are needed to establish the neutron economy and the fuel management. 9 refs

  3. Safe Sleep for Babies

    Science.gov (United States)

    ... 5 MB] Read the MMWR Science Clips Safe Sleep for Babies Eliminating hazards Recommend on Facebook Tweet ... Page Problem Every year, there are thousands of sleep-related deaths among babies. View large image and ...

  4. Escola segura Safe school

    Directory of Open Access Journals (Sweden)

    Edson Ferreira Liberal

    2005-11-01

    Full Text Available OBJETIVO: Revisão das estratégias para tornar o ambiente escolar seguro. Inicialmente os autores contextualizam a violência e os acidentes no ambiente escolar e fazem recomendações, baseadas em dados da literatura, para a implantação de escolas seguras. FONTE DE DADOS: Artigos publicados entre 1993 e 2005 na base de dados MEDLINE. Dados nacionais epidemiológicos e da literatura também foram pesquisados. SÍNTESE DOS DADOS: Há evidência crescente de que a intervenção tem múltiplos componentes. O foco político é a prática em educação em saúde com o envolvimento de toda a comunidade. O norte dessas intervenções é ajudar estudantes e toda a comunidade a adotar um comportamento seguro e saudável. As escolas estão assumindo um envolvimento crescente na promoção da saúde, prevenção de doenças e prevenção de trauma. Nesse contexto de prevenção de causas externas de morbimortalidade, é importante reconhecer o risco ambiental, locais e comportamentos de risco como favoráveis ao trauma e à violência, além de um novo conceito de acidentes como algo que possa ser evitado. CONCLUSÃO: A implementação da escola segura representa uma nova direção promissora para o trabalho preventivo baseado na escola. É importante notar que uma escola segura deve intervir não meramente na sua estrutura física, mas também torná-la tão segura quanto possível, trabalhando com a comunidade escolar por meio de educação em saúde, discutindo principalmente o comportamento saudável.OBJECTIVE: To review the strategies to make school a safe environment. The paper first addresses the social context of accidents and violence in the school environment, and makes recommendations, based on the literature data, for the implementation of safe schools. SOURCE OF DATA: Articles published between 1993 and 2005 in the MEDLINE database. Brazilian epidemiological and literature data have also been searched. SUMMARY OF THE FINDINGS: There is

  5. Buying & Using Medicine Safely

    Science.gov (United States)

    ... Reducers Safe Daily Use of Aspirin Medication Health Fraud Resources for You FDA Consumer Updates (Drugs) Page ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  6. Safe management of sealed radioactive sources at Karachi nuclear power complex

    International Nuclear Information System (INIS)

    Tahir, T.B.; Qamar, A.

    2000-01-01

    This paper describes the conditioning of sealed radioactive sources, carried out at the Karachi Nuclear Power Complex (KNPC) in co-operation with the IAEA. The radioactive sources were radium needles of various size, used by various radiotherapy units in different hospitals throughout the country. For some time the use of radium needles had been abandoned and they were stored in hospitals awaiting proper disposal. Since their storage conditions were not ideal and there was a potential of leakage of radioactive material into the environment, it was decided to condition and store them safely. A significant logistic effort was required to identify these sources, bring them to a central facility and condition them according to current international standards. Various steps were involved in conditioning the sources: place it in a stainless steel capsule, weld the capsule, test it for a leak, place the capsule in a lead shielded package, put and seal the shielded package in a concrete-lined steel drum and finally store it at the waste storage facility. A total amount of about 1500 mg of Radium needles were conditioned. Radiation exposure during the entire operation was within acceptable limits. (author)

  7. Virus Alert: Ten Steps to Safe Computing.

    Science.gov (United States)

    Gunter, Glenda A.

    1997-01-01

    Discusses computer viruses and explains how to detect them; discusses virus protection and the need to update antivirus software; and offers 10 safe computing tips, including scanning floppy disks and commercial software, how to safely download files from the Internet, avoiding pirated software copies, and backing up files. (LRW)

  8. Stabilization and shutdown of Oak Ridge National Laboratory's Radioisotopes Production Facility

    International Nuclear Information System (INIS)

    Eversole, R.E.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has been involved in the production and distribution of a variety of radioisotopes for medical, scientific and industrial applications since the late 1940s. Production of these materials was concentrated in a number of facilities primarily built in the 1950s and 1960s. Due to the age and deteriorating condition of these facilities, it was determined in 1989 that it would not be cost effective to upgrade these facilities to bring them into compliance with contemporary environmental, safety and health standards. The US Department of Energy (DOE) instructed ORNL to halt the production of isotopes in these facilities and maintain the facilities in safe standby condition while preparing a stabilization and shutdown plan. The goal was to place the former isotope production facilities in a radiologically and industrially safe condition to allow a 5-year deferral of the initiation of environmental restoration (ER) activities. In response to DOE's instructions, ORNL identified 17 facilities for shutdown, addressed the shutdown requirements for each facility, and prepared and implemented a three-phase, 4-year plan for shutdown of the facilities. The Isotopes Facilities Shutdown Program (IFSP) office was created to execute the stabilization and shutdown plan. The program is entering its third year in which the actual shutdown of the facilities is initiated. Accomplishments to date have included consolidation of all isotopes inventory into one facility, DOE approval of the IFSP Environmental Assessment (EA), and implementation of a detailed management plan for the shutdown of the facilities

  9. Safe operation of critical assemblies and research reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1960-09-15

    Some countries have accumulated considerable experience in the operation of these reactors and have in the process developed safe practices. On the other hand, other countries which have recently acquired, or will soon acquire, such reactors do not have sufficient background of experience with them to have developed full knowledge regarding their safe operation. In this situation, the International Atomic Energy Agency has considered that it would be useful to make available to all its Member States a set of recommendations on the safe operation of these reactors, based on the accumulated experience and best practices. The Director General accordingly nominated a Pane Ion Safe Operation of Critical Assemblies and Research Reactors to assist the Agency's Secretariat in drafting such recommendations

  10. Safe medication management in specialized home healthcare - an observational study.

    Science.gov (United States)

    Lindblad, Marléne; Flink, Maria; Ekstedt, Mirjam

    2017-08-24

    Medication management is a complex, error-prone process. The aim of this study was to explore what constitutes the complexity of the medication management process (MMP) in specialized home healthcare and how healthcare professionals handle this complexity. The study is theoretically based in resilience engineering. Data were collected during the MMP at three specialized home healthcare units in Sweden using two strategies: observation of workplaces and shadowing RNs in everyday work, including interviews. Transcribed material was analysed using grounded theory. The MMP in home healthcare was dynamic and complex with unclear boundaries of responsibilities, inadequate information systems and fluctuating work conditions. Healthcare professionals adapted their everyday clinical work by sharing responsibility and simultaneously being authoritative and preserving patients' active participation, autonomy and integrity. To promote a safe MMP, healthcare professionals constantly re-prioritized goals, handled gaps in communication and information transmission at a distance by creating new bridging solutions. Trade-offs and workarounds were necessary elements, but also posed a threat to patient safety, as these interim solutions were not systematically evaluated or devised learning strategies. To manage a safe medication process in home healthcare, healthcare professionals need to adapt to fluctuating conditions and create bridging strategies through multiple parallel activities distributed over time, space and actors. The healthcare professionals' strategies could be integrated in continuous learning, while preserving boundaries of safety, instead of being more or less interim solutions. Patients' and family caregivers' as active partners in the MMP may be an underestimated resource for a resilient home healthcare.

  11. Safe use of nanomaterials

    CERN Multimedia

    2013-01-01

    The use of nanomaterials  is on the increase worldwide, including at CERN. The HSE Unit has established a safety guideline to inform you of the main requirements for the safe handling and disposal of nanomaterials at CERN.   A risk assessment tool has also been developed which guides the user through the process of evaluating the risk for his or her activity. Based on the calculated risk level, the tool provides a list of recommended control measures.   We would therefore like to draw your attention to: Safety Guideline C-0-0-5 - Safe handling and disposal of nanomaterials; and Safety Form C-0-0-2 - Nanomaterial Risk Assessment   You can consult all of CERN’s safety rules and guidelines here. Please contact the HSE Unit for any questions you may have.   The HSE Unit

  12. 25 CFR 700.55 - Decent, safe, and sanitary dwelling.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Decent, safe, and sanitary dwelling. 700.55 Section 700... PROCEDURES General Policies and Instructions Definitions § 700.55 Decent, safe, and sanitary dwelling. (a) General. The term decent, safe, and sanitary dwelling means a dwelling which— (1) Meets applicable federal...

  13. Project SFR 1 SAR-08. Update of priority of FEPs from Project SAFE

    International Nuclear Information System (INIS)

    Gordon, Anna; Loefgren, Martin; Lindgren, Maria

    2008-03-01

    SFR 1 is a repository for final disposal of low and intermediate level radioactive waste produced at Swedish nuclear power plants, as well as at Swedish industrial, research, and medical treatment facilities. The repository obtained operational license in March 1988. The aim of Project SFR 1 SAR-08 is to perform an updated safety analysis, according to requirements in the regulations. A major difference between this and previous safety analyses is that repository safety should be demonstrated for 100,000 years after repository closure. This should be compared with the time frame of the safety assessment in Project SAFE that was 10,000 years. Due to the extended time frame, permafrost and glaciation have to be considered in the reference evolution of Project SFR 1 SAR-08. Other rationales for the update are recent input from the authorities concerning SAFE documents and the SFR 1 repository, as well as new data concerning the SFR 1 inventory. This report describes the outcome of revisiting the qualitative FEP (Features, Events and Processes) analysis carried out within Project SAFE for the SFR 1 repository. Each and every interaction definition, as defined in SAFE, has been examined with the aim at assuring that the SAFE interaction matrices are also applicable for SAR-08. It was found that this is generally the case, but seven new interactions were defined in order to make the interaction matrices more applicable for SAR-08. The priority of all interactions assigned priority 1 and many interactions assigned priority 2 in SAFE have been carefully examined. The examination has been made in the context of the general initial and boundary conditions that should also form the basis for the SAR-08 main scenario and less probable scenarios. In 48 cases, the priority of the interaction needed upgrading, compared to in SAFE. In a majority of these cases, the upgrade is due to the extended time frame of the safety assessment, from 10,000 years in SAFE to 100,000 years in SAR

  14. Project SFR 1 SAR-08. Update of priority of FEPs from Project SAFE

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Anna (Swedish Nuclear Fuel and Waste Management Co., Stockholm (SE)); Loefgren, Martin; Lindgren, Maria (Kemakta Konsult AB, Stockholm (SE)) (eds.)

    2008-03-15

    SFR 1 is a repository for final disposal of low and intermediate level radioactive waste produced at Swedish nuclear power plants, as well as at Swedish industrial, research, and medical treatment facilities. The repository obtained operational license in March 1988. The aim of Project SFR 1 SAR-08 is to perform an updated safety analysis, according to requirements in the regulations. A major difference between this and previous safety analyses is that repository safety should be demonstrated for 100,000 years after repository closure. This should be compared with the time frame of the safety assessment in Project SAFE that was 10,000 years. Due to the extended time frame, permafrost and glaciation have to be considered in the reference evolution of Project SFR 1 SAR-08. Other rationales for the update are recent input from the authorities concerning SAFE documents and the SFR 1 repository, as well as new data concerning the SFR 1 inventory. This report describes the outcome of revisiting the qualitative FEP (Features, Events and Processes) analysis carried out within Project SAFE for the SFR 1 repository. Each and every interaction definition, as defined in SAFE, has been examined with the aim at assuring that the SAFE interaction matrices are also applicable for SAR-08. It was found that this is generally the case, but seven new interactions were defined in order to make the interaction matrices more applicable for SAR-08. The priority of all interactions assigned priority 1 and many interactions assigned priority 2 in SAFE have been carefully examined. The examination has been made in the context of the general initial and boundary conditions that should also form the basis for the SAR-08 main scenario and less probable scenarios. In 48 cases, the priority of the interaction needed upgrading, compared to in SAFE. In a majority of these cases, the upgrade is due to the extended time frame of the safety assessment, from 10,000 years in SAFE to 100,000 years in SAR

  15. Project SFR 1 SAR-08. Update of priority of FEPs from Project SAFE

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Anna [Swedish Nuclear Fuel and Waste Management Co., Stockholm (SE); Loefgren, Martin; Lindgren, Maria [Kemakta Konsult AB, Stockholm (SE); eds.

    2008-03-15

    SFR 1 is a repository for final disposal of low and intermediate level radioactive waste produced at Swedish nuclear power plants, as well as at Swedish industrial, research, and medical treatment facilities. The repository obtained operational license in March 1988. The aim of Project SFR 1 SAR-08 is to perform an updated safety analysis, according to requirements in the regulations. A major difference between this and previous safety analyses is that repository safety should be demonstrated for 100,000 years after repository closure. This should be compared with the time frame of the safety assessment in Project SAFE that was 10,000 years. Due to the extended time frame, permafrost and glaciation have to be considered in the reference evolution of Project SFR 1 SAR-08. Other rationales for the update are recent input from the authorities concerning SAFE documents and the SFR 1 repository, as well as new data concerning the SFR 1 inventory. This report describes the outcome of revisiting the qualitative FEP (Features, Events and Processes) analysis carried out within Project SAFE for the SFR 1 repository. Each and every interaction definition, as defined in SAFE, has been examined with the aim at assuring that the SAFE interaction matrices are also applicable for SAR-08. It was found that this is generally the case, but seven new interactions were defined in order to make the interaction matrices more applicable for SAR-08. The priority of all interactions assigned priority 1 and many interactions assigned priority 2 in SAFE have been carefully examined. The examination has been made in the context of the general initial and boundary conditions that should also form the basis for the SAR-08 main scenario and less probable scenarios. In 48 cases, the priority of the interaction needed upgrading, compared to in SAFE. In a majority of these cases, the upgrade is due to the extended time frame of the safety assessment, from 10,000 years in SAFE to 100,000 years in SAR

  16. Transfer pricing and safe harbours

    Directory of Open Access Journals (Sweden)

    Veronika Solilová

    2013-01-01

    Full Text Available Transfer prices are significant for both taxpayers and tax administrations because they determine in large part taxable profits of associated enterprises in different tax jurisdictions. Moreover, in the context of taxation, transfer prices must be complied with the arm’s length principle. However, Multinational Enterprises have been faced daily by conflicting rules and approaches to applying the arm’s length principle, burdensome documentation requirements, inconsistent audit standards and unpredictable competent authority outcomes. Therefore, the Committee on Fiscal Affairs launched another project on the administrative aspects of transfer pricing in 2010. On 16 May 2013 as a partial solution of this project was approved by the OECD Council the Revised Section E on Safe Harbours in Chapter IV of the Transfer Pricing Guidelines for Multinational Enterprises and Tax Authorities. The paper is focused on significant changes of newly approved chapter IV of the Transfer Pricing Guidelines for Multinational Enterprises and Tax Authorities, further on analysis of practice in this area, on advantages and disadvantages of safe harbours for taxpayers and competent authorities with aim to suggest recommendations on use of safe harbours in the Czech Republic.

  17. On general principles of supplying safe operation of sea objects of Russian Federation oil and gas complex in ice conditions

    Directory of Open Access Journals (Sweden)

    Kukui Firmin Jeevo

    2016-12-01

    Full Text Available Ice sheet exerts a force on the hydraulic structures and vessels with developing and transporting hydrocarbons in the offshore waters of the Arctic causing to strengthen their design and/or provide additional measures against ice loads. The risk of ice impacts on objects of offshore oil and gas fields of the Arctic region determines the existence of the problem of ensuring the sustainability of these objects in terms of iceberg danger and ice formations. Reducing these risks involves the development of organizational and technical measures for improving the sustainability of the facilities in terms of iceberg danger through the use of international experience and development of advanced technologies to prevent dangerous effects of ice formations. Based on the fact that ice management is a specific activity that requires special effort and funds which as part of the rescue security (RS forces at sea are missing, as well as on the basis of the fact that the system of RS at sea is not assigned to prevent accidents and to ensure the smooth operation of offshore facilities, an ice management is seen as an independent kind of ensuring the proper functioning objects of hydrocarbons production and marine transportation. The paper considers the analysis and synthesis of domestic and foreign experience of ice and iceberg management. A system of security measures for functioning marine oil and gas facilities in icy conditions on the basis of technology of preventing dangerous effects of ice formations has been worked out. It has been shown that the system of ice and iceberg management of marine objects of hydrocarbon production and marine transportation should be a practical mechanism for reducing deposits' operation risks in ice conditions. The work relates to the safe operation of mining platforms in the Arctic seas, and more particularly, to methods and means of influence on the icebergs in order to prevent collisions with fixed or floating production

  18. Safe Energy Source in Battery-operated Toys for Children.

    Science.gov (United States)

    Rossi, Alfredo; Vignola, Silvia; Nason, Francesca; Boschetti, Federica; Bramerio, Manuela; Bailini, Alessandro; Pinarello, Giordano

    2017-11-01

    Serious and even fatal consequences of disk batteries ingestion in children are well known. Among other applications, disk batteries are used to power small toys, from which they can be unexpectedly extracted and swallowed. We tested a new cell intended for little toys (green cell [GC]), after 6 and 12 hours of in vitro close contact with esophageal swine mucosa. The GC was compared with lithium and silver button batteries under the same experimental conditions. Tissues in contact with the GC did not show pH variations nor histological alterations after 6 and 12 hours. In such conditions, statistically significant differences were found between the GC and the lithium and silver batteries. So far, multidisciplinary medical effort has been driven to both emergency approach and subsequent operative strategies in children with ingested batteries. Our trial demonstrates the possibility to primarily prevent battery-induced damages by designing new-generation safe cells with no tissue toxicity to power little toys intended for children.

  19. Inherently safe technologies-chemical and nuclear

    International Nuclear Information System (INIS)

    Weinberg, A.M.

    1984-01-01

    Probabilistic risk assessments show an inverse relationship between the likelihood and the consequences of nuclear and chemical plant accidents, but the Bhopal accident has change public complacency about the safety of chemical plants to such an extent that public confidence is now at the same low level as with nuclear plants. The nuclear industry's response was to strengthen its institutions and improve its technologies, but the public may not be convinced. One solution is to develop reactors which do not depend upon the active intervention of humans of electromechanical devices to deal with emergencies, but which have physical properties that limit the possible temperature and power of a reactor. The Process Inherent Ultimately Safe and the modular High-Temperature Gas-Cooled reactors are two possibilities. the chemical industry needs to develop its own inherently safe design precepts that incorporate smallness, safe processes, and hardening against sabotage. 5 references

  20. Intrinsically Safe and Economical Reactor (ISER)

    International Nuclear Information System (INIS)

    Wakabayashi, Hiroaki; Asahi, Yoshiro

    1991-01-01

    The Intrinsically Safe and Economical Reactor (ISER) is designed based on the principle of a process inherent ultimate safe reactor, PIUS, a so-called inherently safe reactor (ISR). ISER has been developed joingly by the members of the Kanagawa Institute of Technology, the University of Tokyo, the Japan Atomic Energy Research Institute (JAERI) and several industrial firms in Japan. This paper describes the requirements for the next generation of power reactor, the safety design philosphy of ISR and ISER, the controllability of ISER and the results of analyses of some of the design-based accidents (DBA) of ISER, namely station blackout, accidents in which the pressurizer relief valve becomes jammed and stuck in open position and tube breaks in the steam generator. It is concluded that the ISER can ensure a wide range of contraollabitily and fuel integrity for all the analysed DBAs. (orig.)

  1. Effects of the SAFE Children preventive intervention on developmental trajectories of attention-deficit/hyperactivity disorder symptoms.

    Science.gov (United States)

    Fowler, Patrick J; Henry, David B; Schoeny, Michael; Gorman-Smith, Deborah; Tolan, Patrick H

    2014-11-01

    This study examined whether a family-based preventive intervention for inner-city children entering the first grade could alter the developmental course of attention-deficit/hyperactivity disorder (ADHD) symptoms. Participants were 424 families randomly selected and randomly assigned to a control condition (n = 192) or Schools and Families Educating Children (SAFE) Children (n = 232). SAFE Children combined family-focused prevention with academic tutoring to address multiple developmental-ecological needs. A booster intervention provided in the 4th grade to randomly assigned children in the initial intervention (n =101) evaluated the potential of increasing preventive effects. Follow-up occurred over 5 years with parents and teachers reporting on attention problems. Growth mixture models identified multiple developmental trajectories of ADHD symptoms. The initial phase of intervention placed children on more positive developmental trajectories for impulsivity and hyperactivity, demonstrating the potential for ADHD prevention in at-risk youth, but the SAFE Children booster had no additional effect on trajectory or change in ADHD indicators.

  2. Safe Operation of Nuclear Power Plants. Code of Practice and Technical Appendices

    International Nuclear Information System (INIS)

    1969-01-01

    This book is in two parts. The first is a Code of Practice for the Safe Operation of Nuclear Power Plants and the second part is a compilation of technical appendices. Its object is to give information and illustrative examples that would be helpful in implementing the Code of Practice. This second part, although published under the same cover, is not part of the Code. Safe operation of a nuclear power plant postulates suitable siting and proper design, construction and management of the plant. Under the present Code of Practice for the Safe Operation of Nuclear Power Plants, those intending to operate the plant are recommended to prepare documentation which would deal with its operation and include safety analyses. The documentation in question would be reviewed by a regulatory body independent of the operating organization; operation would be authorized on the understanding that it would comply with limits and conditions designed to ensure safety. The Code may be subject to revision in the light of experience. The Appendices provide additional information together with some examples relating to certain topics dealt with in the Code; it must be emphasized that they are included as examples for information only and are not part of any recommendation. Purpose and scope: The recommendations in the Code are designed to protect the general public and the operating personnel from radiation hazards, and the Code forms part of the Agency's Safety Standards. The Code, which should be used in conjunction with the Agency's other Safety Standards, provides guidance and information to persons and authorities responsible for the operation of stationary nuclear power plants whose main function is the generation of thermal, mechanical or electrical power; it is not intended to apply to reactors used solely for experimental or research purposes. It sets forth minimum requirements which, it is believed, in the light of experience, must be met in order to achieve safe operation of a

  3. 40 CFR 144.51 - Conditions applicable to all permits.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Permit Conditions § 144.51 Conditions applicable... permit. Any permit noncompliance constitutes a violation of the Safe Drinking Water Act and is grounds... denial of a permit renewal application; except that the permittee need not comply with the provisions of...

  4. Definition of the «Economic Security of an Enterprise» and «Safe Development of an Enterprise» Notions

    Directory of Open Access Journals (Sweden)

    Yefimova Ganna V.

    2013-11-01

    Full Text Available The necessity of this study is explained by difference of opinions regarding understanding of the “economic security of an enterprise” notion, on the one hand, and the poorly studied issue of a combination of the process of enterprise development with a necessary task of ensuring a high level of its economic security, on the other hand. Analysing, systemising and generalising results of scientific studies, the article identifies that economic security of an enterprise is an economic category, which characterises the enterprise functioning conditions. Favourable conditions of functioning ensure a high level of stability and steadiness of an enterprise and its ability of self-realisation and expanded self-reproduction. This becomes possible if an enterprise is capable of resisting external threats and preventing internal ones. Since development of an enterprise is an objective process, which takes place under conditions of uncertainty and changeability of external and internal environments, it is accompanied with a system of threats, which the system of economic security should protect an enterprise from. Taking into account the above, safe development of an enterprise is a process of consecutive transitions of the economic system from one state to another, which is not of a poorer quality than a previous one, which envisages producing new goals and creation of safe conditions for transition from one specific goal, achieved in the process of enterprise functioning, to another. The proposed definitions allow consideration of such significant issues of methodology of management of safe development of an enterprise as the diagnostics of its level and planning.

  5. THE CONSEQUENCES OF GLOBALIZATION UPON SAFE TOURISM

    Directory of Open Access Journals (Sweden)

    Svetlana Mihić

    2009-11-01

    Full Text Available Globalization, a phenomenon on the rise, is characterized by the free cross-bor- der movement of individuals, technologies, and capital. It has far- reaching consequen- ces for tourism, too, as it implies travel for leisure and business, and correspondingly, financial transfers between various nation states. Startinf from the status quo in the field, the current paper sets out to analyze the consequences and implications of globalization upon safe tourism and conduct a marketing research into the perceptions of consumers upon Serbia as a safe vacation destination for the purpose of safe tourism. Finally the research results will be presented and several solutions will be provided for improving security in tourism zones

  6. Sun Safe Mode Controller Design for LADEE

    Science.gov (United States)

    Fusco, Jesse C.; Swei, Sean S. M.; Nakamura, Robert H.

    2015-01-01

    This paper presents the development of sun safe controllers which are designed to keep the spacecraft power positive and thermally balanced in the event an anomaly is detected. Employed by NASA's Lunar Atmosphere and Dust Environment Explorer (LADEE), the controllers utilize the measured sun vector and the spacecraft body rates for feedback control. To improve the accuracy of sun vector estimation, the least square minimization approach is applied to process the sensor data, which is proven to be effective and accurate. To validate the controllers, the LADEE spacecraft model engaging the sun safe mode was first simulated and then compared with the actual LADEE orbital fight data. The results demonstrated the applicability of the proposed sun safe controllers.

  7. The Blue Dog: evaluation of an interactive software program to teach young children how to interact safely with dogs.

    Science.gov (United States)

    Schwebel, David C; Morrongiello, Barbara A; Davis, Aaron L; Stewart, Julia; Bell, Melissa

    2012-04-01

    Pre-post-randomized design evaluated The Blue Dog, a dog safety software program. 76 children aged 3.5-6 years completed 3 tasks to evaluate dog safety pre- and postintervention: (a) pictures (recognition of safe/risky behavior), (b) dollhouse (recall of safe behavior via simulated dollhouse scenarios), and (c) live dog (actual behavior with unfamiliar live dog). Following preintervention evaluation, children were randomly assigned to dog or fire safety conditions, each involving 3 weeks of home computer software use. Children using Blue Dog had greater change in recognition of risky dog situations than children learning fire safety. No between-group differences emerged in recall (dollhouse) or engagement (live-dog) in risky behavior. Families enjoyed using the software. Blue Dog taught children knowledge about safe engagement with dogs, but did not influence recall or implementation of safe behaviors. Dog bites represent a significant pediatric injury concern and continued development of effective interventions is needed.

  8. Study of the ‘lifeline’ as the measure allowing for safe self-rescue of miners in conditions of lack of visibility caused by underground fire

    Science.gov (United States)

    Badura, Henryk; Grodzicka, Aneta; Musioł, Dariusz

    2017-11-01

    The article presents statistical data regarding the evacuation of miners affected by underground fire hazards. The data indicates that the hazard remains considerable. Due to the increasing lengths of escape routes, measures should be introduced in the longwall regions, which shall improve the safe evacuation of miners, especially in conditions of highly limited visibility or the lack thereof. Within the research project No. 12, entitled: ‘The development of orientation systems and systems for signalling the direction of crew withdrawal for escape routes in longwall gates’, which is a part of the Strategic Research Project entitled ‘The improvement of work safety in mines’ financed by the National Centre for Research and Development, a ‘lifeline’ was designed - that is, a measure that is very effective in the evacuation of staff. Subsequently, tests of time of passage were conducted in the ‘Krupiński’ coal mine in conditions of lack of visibility. The tests have confirmed the suitability of the ‘lifeline’ as the measure used for orientation towards the correct direction of evacuation, which increases the pace and the confidence while travelling through the escape route. The mean speed of passage through the heading with an upwards inclination of 11° was 22 m/min, while in case of a nearly horizontal longwall gate, it was 39 m/min.

  9. Influencing behaviour for safe working environments

    OpenAIRE

    Boer, de, J. (Johannes); Teeuw, W.B. (Wouter)

    2011-01-01

    Safety at work The objective of the project Safety at Work is to increase safety at the workplace by applying and combining state of the art artefacts from personal protective equipment and ambient intelligence technology. In this state of the art document we focus on the developments with respect to how (persuasive) technology can help to influence behaviour in a natural, automatic way in order to make industrial environments safer. We focus on personal safety, safe environments and safe beh...

  10. Safe management of waste from health-care activities

    International Nuclear Information System (INIS)

    Pruess, A.; Giroult, E.; Rushbrook, P.

    1999-01-01

    The waste produced in the course of health-care activities, from contaminated needles to radioactive isotopes, carries a greater potential for causing infection and injury than any other type of waste, and inadequate or inappropriate management is likely to have serious public health consequences and deleterious effects on the environment. This handbook - the result of extensive international consultation and collaboration - provides comprehensive guidance on safe, efficient, and environmentally sound methods for the handling and disposal of health-care wastes. The various categories of waste are clearly defined and the particular hazards that each poses are described. Considerable prominence is given to the careful planning that is essential for the success of waste management; workable means of minimizing waste production are outlined and the role of reuse and recycling of waste is discussed. Most of the text, however, is devoted to the collection, segregation, storage, transport, and disposal of wastes. Details of containers for each category of waste, labelling of waste packages, and storage conditions are provided, and the various technologies for treatment of waste and disposal of final residues are discussed at length. Advice is given on occupational safety for all personnel involved with waste handling, and a separate chapter is devoted to the closely related topic of hospital hygiene and infection control. The handbook pays particular attention to basic processes and technologies that are not only safe but also affordable, sustainable, and culturally appropriate. For health-care settings in which resources are severely limited there is a separate chapter on minimal programmes; this summarizes all the simplest and least costly techniques that can be employed for the safe management of health-care wastes. The guide is aimed at public health managers and policy-makers, hospital managers, environmental health professionals, and all administrators with an

  11. Now, It's Your Turn: How You Can Take Medicine Safely

    Science.gov (United States)

    ... turn Javascript on. Feature: Taking Medicines Safely Now, It's Your Turn: How You Can Take Medicine Safely ... medicine. The pharmacist has filled the prescription. Now it's up to you to take the medicine safely. ...

  12. A 'simple anterior fish excluder' (SAFE for mitigating penaeid-trawl bycatch.

    Directory of Open Access Journals (Sweden)

    Matthew J McHugh

    Full Text Available Various plastic strips and sheets (termed 'simple anterior fish excluders'-SAFEs were positioned across the openings of penaeid trawls in attempts at reducing the unwanted bycatches of small teleosts. Initially, three SAFEs (a single wire without, and with small and large plastic panels were compared against a control (no SAFE on paired beam trawls. All SAFEs maintained targeted Metapenaeus macleayi catches, while the largest plastic SAFE significantly reduced total bycatch by 51% and the numbers of Pomatomus saltatrix, Mugil cephalus and Herklotsichthys castelnaui by up to 58%. A redesigned SAFE ('continuous plastic' was subsequently tested (against a control on paired otter trawls, significantly reducing total bycatch by 28% and P. saltatrix and H. castelnaui by up to 42%. The continuous-plastic SAFE also significantly reduced M. macleayi catches by ~7%, but this was explained by ~5% less wing-end spread, and could be simply negated through otter-board refinement. Further work is required to refine the tested SAFEs, and to quantify species-specific escape mechanisms. Nevertheless, the SAFE concept might represent an effective approach for improving penaeid-trawl selectivity.

  13. Leaking electricity in domestic appliances

    International Nuclear Information System (INIS)

    Meier, Alan; Rosen, Karen

    1999-01-01

    Many types of home electronic equipment draw electric power when switched off or not performing their principal functions. Standby power use (or ''leaking electricity'') for most appliances ranges from 1 - 20 watts. Even though standby use of each device is small, the combined standby power use of all appliances in a home can easily exceed 50 watts. Leaking electricity is already responsible for 5 to 10 percent of residential electricity use in the United States and over 10 percent in Japan. An increasing number of white goods also have standby power requirements. There is a growing international effort to limit standby power to around one watt per device. New and existing technologies are available to meet this target at little or no extra cost

  14. Investigation on the Short Circuit Safe Operation Area of SiC MOSFET Power Modules

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Luo, Haoze; Iannuzzo, Francesco

    2016-01-01

    This paper gives a better insight of the short circuit capability of state-of-the-art SiC MOSFET power modules rated at 1.2 kV by highlighting the physical limits under different operating conditions. Two different failure mechanisms have been identified, both reducing the short-circuit capability...... of SiC power modules in respect to discrete SiC devices. Based on such failure mechanisms, two short circuit criteria (i.e., short circuit current-based criterion and gate voltage-based criterion) are proposed in order to ensure their robustness under short-circuit conditions. A Safe Operation Area (SOA...

  15. The safe transport of radioactive materials

    CERN Document Server

    Gibson, R

    1966-01-01

    The Safe Transport of Radioactive Materials is a handbook that details the safety guidelines in transporting radioactive materials. The title covers the various regulations and policies, along with the safety measures and procedures of radioactive material transport. The text first details the 1963 version of the IAEA regulation for the safe transport of radioactive materials; the regulation covers the classification of radionuclides for transport purposes and the control of external radiation hazards during the transport of radioactive materials. The next chapter deals with concerns in the im

  16. Safe taste memory consolidation is disrupted by a protein synthesis inhibitor in the nucleus accumbens shell.

    Science.gov (United States)

    Pedroza-Llinás, R; Ramírez-Lugo, L; Guzmán-Ramos, K; Zavala-Vega, S; Bermúdez-Rattoni, F

    2009-07-01

    Consolidation is the process by which a new memory is stabilized over time, and is dependent on de novo protein synthesis. A useful model for studying memory formation is gustatory memory, a type of memory in which a novel taste may become either safe by not being followed by negative consequences (attenuation of neophobia, AN), or aversive by being followed by post-digestive malaise (conditioned taste aversion, CTA). Here we evaluated the effects of the administration of a protein synthesis inhibitor in the nucleus accumbens (NAc) shell for either safe or aversive taste memory trace consolidation. To test the effects on CTA and AN of protein synthesis inhibition, anisomycin (100microg/microl) was bilaterally infused into the NAc shell of Wistar rats' brains. We found that post-trial protein synthesis blockade impaired the long-term safe taste memory. However, protein synthesis inhibition failed to disrupt the long-term memory of CTA. In addition, we infused anisomycin in the NAc shell after the pre-exposure to saccharin in a latent inhibition of aversive taste. We found that the protein synthesis inhibition impaired the consolidation of safe taste memory, allowing the aversive taste memory to form and consolidate. Our results suggest that protein synthesis is required in the NAc shell for consolidation of safe but not aversive taste memories, supporting the notion that consolidation of taste memory is processed in several brain regions in parallel, and implying that inhibitory interactions between both taste memory traces do occur.

  17. Combined SAFE/SNAP approach to safeguards evaluation

    International Nuclear Information System (INIS)

    Engi, D.; Chapman, L.D.; Grant, F.H.; Polito, J.

    1980-01-01

    Generally, the scope of a safeguards evaluation model can efficiently address one of two issues, (1) global safeguards effectiveness, or (2) vulnerability analysis for individual scenarios. The Safeguards Automated Facility Evaluation (SAFE) focuses on (1) while the Safeguards Network Analysis Procedure (SNAP) is directed at (2). SAFE addresses (1) in that it considers the entire facility, i.e., the composite system of hardware and human components, in one global analysis. SNAP addresses (2) by providing a safeguards modeling symbology sufficiently flexible to represent quite complex scenarios from the standpoint of hardware interfaces while also accounting for a rich variety of human decision making. A combined SAFE/SNAP approach to the problem of safeguards evaluation is described and illustrated through an example

  18. Development of Safe Food Handling Guidelines for Korean Consumers.

    Science.gov (United States)

    Kang, Hee-Jin; Lee, Min-Woo; Hwang, In-Kyeong; Kim, Jeong-Weon

    2015-08-01

    The purpose of this study was to develop guidelines for Korean consumers with regard to safe food handling practices at home by identifying current food handling issues. Korean consumers' behaviors regarding their safe food handling were identified via survey questionnaires that included items on individual hygiene practices, prepreparation steps when cooking, the cooking process, and the storage of leftover foods. The subjects were 417 Korean parents with elementary school children living in Seoul and Gyeonggi Province in the central area of Korea. The survey results revealed gaps between the knowledge or practices of Korean consumers and scientific evidence pertaining to safe food handling practices. Based on these findings, a leaflet on safe food handling guidelines was developed in accordance with Korean food culture. These guidelines suggest personal hygiene practices as well as fundamental principles and procedures for safe food handling from the stage of food purchase to that of keeping leftover dishes. A pilot application study with 50 consumers revealed that the guidelines effectively improved Korean consumers' safe food handling practices, suggesting that they can serve as practical educational material suitable for Korean consumers.

  19. Method for reducing power consumption in a state retaining circuit, state reaining circuit and electronic device.

    NARCIS (Netherlands)

    2006-01-01

    A method for reducing the power consumption in a state retaining circuit during a standby mode is disclosed comprising, in an active state, providing a regular power supply (VDD) and a standby power supply (VDD STANDBY) to the state retaining circuit; for a transition from an active state to a

  20. Safe-haven CDS Premia

    DEFF Research Database (Denmark)

    Klingler, Sven; Lando, David

    We argue that Credit Default Swap (CDS) premia for safe-haven sovereigns, like Germany and the United States, are driven to a large extent by regulatory requirements under which derivatives dealing banks have an incentive to buy CDS to hedge counterparty credit risk of their counterparties. We...

  1. Safe lengthening of a drillpipe string by stands

    Energy Technology Data Exchange (ETDEWEB)

    Karapetyan, K.V.; Khrennikov, S.B.; Voyevoda, A.N.

    1979-01-01

    In order to prevent dragging of the block and tackle under the ground block, each drilling rig is equipped with block and tackle lift limiter. However these devices reduce the useful height of the derricks. Studies were carried out to achieve safe conditions for lengthening drillpipe strings with stands and advance of the borehole with a set of drilling stands. The basic precepts of this research were used to design the new drilling rig Uralmash-3000 EUK. In addition an increase of derrick height by 2.5 m was recommended for effective use of production drilling rigs BU-80. In order to lengthen the derrick a special support under the crown block articulated to the upper sections of the feet of the derrick with a frame under the crown block should be used.

  2. Operational experience of air washer based ventilation system for power conditioning system of Indus-2

    International Nuclear Information System (INIS)

    Pandey, R.M.; Baghel, S.L.; Parate, J.K.; Ahlawat, Sandeep; Rawlani, B.K.; Chouksey, Sanjay

    2015-01-01

    Indus-2 Synchrotron Accelerator requires high quality conditioned uninterrupted AC mains power for their smooth and reliable operation. Three units of 1670 kVA and one unit of 1100 kVA capacity rotary uninterruptible power conditioning systems (UPS) were installed and commissioned. These UPS units require dust free and cool ambient conditions for smooth operation. In order to meet the ventilation requirements, an evaporative cooling system of 80000 cubic meter/hour capacity with filtration units was designed, installed and commissioned in February 2011 and is operational on round-the-clock basis. Evaporative cooling scheme was chosen as has various advantages over a refrigerated system like lower initial capital costs, lower energy usage, lower running costs, less greenhouse gas and it does not contribute to ozone depletion. The ventilation system filters the environment air in stages up to 5 micron level and being conditioned with an automatic controlled soft water circulating system with cooling pads. An instrumentation and control scheme is included in the system to provide the automation requirements for operating 24 x 7 through the year. All the mechanical, hydraulic and electrical devices are maintained by providing preventive maintenance work without affecting the accelerator machine operation. Availability and reliability of the system was analysed based on the failure data. In Year 2014, the ventilation system was upgraded to accommodate standby blower unit, coupling unit and improved quality of supply air with new air conditioning devices. The control panel monitors the condition of air in the UPS hall and maintainsup to 28°C air temperature and 85% maximum relative humidity in round-the clock shift with more than 98% operational reliability. In this paper, we present design philosophy, installation, instrumentation, testing, operation experience and availability of the ventilation system for Power Conditioning System, Indus complex. (author)

  3. Swimming Safely (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    In the summertime, families will be flocking to pools for relaxation and relief from the heat. A few simple precautions can help ensure a safe day in the water. In this podcast, Michele Hlavsa discusses ways to stay safe at the pool.

  4. How safe are nuclear plants? How safe should they be?

    International Nuclear Information System (INIS)

    Kouts, H.

    1988-01-01

    It has become customary to think about safety of nuclear plants in terms of risk as defined by the WASH-1400 study that some of the implications for the non-specialist escape our attention. Yet it is known that a rational program to understand safety, to identify unsafe events, and to use this kind of information or analysis to improve safety, requires us to use the methods of quantitative risk assessment. How this process can be made more understandable to a broader group of nontechnical people and how can a wider acceptance of the results of the process be developed have been questions under study and are addressed in this report. These are questions that have been struggled with for some time in the world of nuclear plant safety. The Nuclear Regulatory Commission examined them for several years as it moved toward developing a position on safety goals for nuclear plants, a requirement that had been assigned it by Congress. Opinion was sought from a broad spectrum of individuals, within the field of nuclear power and outside it, on the topic that was popularly called, ''How safe is safe enough?'' Views were solicited on the answer to the question and also on the way the answer should be framed when it was adopted. This report discusses the public policy and its implementation

  5. Ergonomics: safe patient handling and mobility.

    Science.gov (United States)

    Hallmark, Beth; Mechan, Patricia; Shores, Lynne

    2015-03-01

    This article reviews and investigates the issues surrounding ergonomics, with a specific focus on safe patient handling and mobility. The health care worker of today faces many challenges, one of which is related to the safety of patients. Safe patient handling and mobility is on the forefront of the movement to improve patient safety. This article reviews the risks associated with patient handling and mobility, and informs the reader of current evidence-based practice relevant to this area of care. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Be-safe travel, a web-based geographic application to explore safe-route in an area

    Science.gov (United States)

    Utamima, Amalia; Djunaidy, Arif

    2017-08-01

    In large cities in developing countries, the various forms of criminality are often found. For instance, the most prominent crimes in Surabaya, Indonesia is 3C, that is theft with violence (curas), theft by weighting (curat), and motor vehicle theft (curanmor). 3C case most often occurs on the highway and residential areas. Therefore, new entrants in an area should be aware of these kind of crimes. Route Planners System or route planning system such as Google Maps only consider the shortest distance in the calculation of the optimal route. The selection of the optimal path in this study not only consider the shortest distance, but also involves other factors, namely the security level. This research considers at the need for an application to recommend the safest road to be passed by the vehicle passengers while drive an area. This research propose Be-Safe Travel, a web-based application using Google API that can be accessed by people who like to drive in an area, but still lack of knowledge of the pathways which are safe from crime. Be-Safe Travel is not only useful for the new entrants, but also useful for delivery courier of valuables goods to go through the safest streets.

  7. Engineering and planning for reactor 105-C interim safe storage project subcontract no. 0100C-SC-G0001 conceptual design report. Volume 1

    International Nuclear Information System (INIS)

    1996-04-01

    The 105-C Reactor, one of eight surplus production reactors at the Hanford Site, has been proposed by the U.S. Department of Energy, Richland, Operations Office to be the first large-scale technology demonstration project in the decontamination and decommissioning (D ampersand D) focus area as part of the project for dismantlement and interim safe storage. The 105-C Reactor will be placed in an interim safe storage condition, then undergo the decontamination and decommissioning phase. After D ampersand D, the reactor will be placed in long- term safe storage. This report provides the conceptual design for these activities

  8. Safe handling of radiation sources

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    This chapter discussed the subjects related to the safe handling of radiation sources: type of radiation sources, method of use: transport within premises, transport outside premises; Disposal of Gamma Sources

  9. Strategies and challenges for safe injection practice in developing countries.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, P Ravi; Kumar, Kc Vikash

    2013-01-01

    Injection is one of the important health care procedures used globally to administer drugs. Its unsafe use can transmit various blood borne pathogens. This article aims to review the history and status of injection practices, its importance, interventions and the challenges for safe injection practice in developing countries. The history of injections started with the discovery of syringe in the early nineteenth century. Safe injection practice in developed countries was initiated in the early twentieth century but has not received adequate attention in developing countries. The establishment of "Safe Injection Global Network (SIGN)" was an milestone towards safe injection practice globally. In developing countries, people perceive injection as a powerful healing tool and do not hesitate to pay more for injections. Unsafe disposal and reuse of contaminated syringe is common. Ensuring safe injection practice is one of the greatest challenges for healthcare system in developing countries. To address the problem, interventions with active involvement of a number of stakeholders is essential. A combination of educational, managerial and regulatory strategies is found to be effective and economically viable. Rational and safe use of injections can save many lives but unsafe practice threatens life. Safe injection practice is crucial in developing countries. Evidence based interventions, with honest commitment and participation from the service provider, recipient and community with aid of policy makers are required to ensure safe injection practice.

  10. Effective and Safe Ships

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup; Amdahl, Jørgen; Rutgersson, Olle

    1996-01-01

    A Joint Nordic Research project "Effecive and Safe Ships" is presented. The project is aiming to develop methods and tools for quantitative evaluation fo ship safety. This report is the report of the preliminary phase where the plan for the main project is developed. The objectives of the project...

  11. The Preliminary Prototype of Medium Dose Rate Brachytherapy Equipment

    Directory of Open Access Journals (Sweden)

    A. Satmoko

    2013-08-01

    Full Text Available A preliminary prototype of a brachytherapy equipment has been constructed. The work started by developing conceptual design, followed by basic design and detailed design. In the conceptual design, design requirements are stated. In the basic design, technical specifications for main components are determined. In detailed design, general drawings are discussed. The prototype consists of three main systems: a mechanical system, an instrumentation system, and a safety system. The mechanical system assures the movement mechanism of the isotope source position beginning from the standby position until the applicators. It consists of three main modules: a position handling module, a container module, and a channel distribution module. The position handling module serves to move the isotope source position. As shielding, the second module is to store the source when the equipment is in standby position. The prototype provides 12 output channels. The channel selection is performed by the third module. The instrumentation system controls the movement of source position by handling motor operations. It consists of several modules. A microcontroller module serves as a control center whose task includes both controlling motors and communicating with computer. A motor module serves to handle motors. 10 sensors, including their signal conditionings, are introduced to read the environment conditions of the equipment. LEDs are used to display these conditions. In order to facilitate the operators’ duty, communication via RS232 is provided. The brachytherapy equipment can therefore be operated by using computer. Interface software is developed using C# language. To complete both mechanical and instrumentation systems performance, a safety system is developed to make sure that the safety for operator and patients from receiving excessive radiation. An interlock system is introduced to guard against abnormal conditions. In the worst case, a manual intervention

  12. Analysis of Methods of Determining the Safe Ship Trajectory

    Directory of Open Access Journals (Sweden)

    Jozef Lisowski

    2016-07-01

    Full Text Available The paper describes six methods of optimal and game theory and artificial neural network for synthesis of safe control in collision situations at sea. The application of optimal and game control algorithms to determine the own ship safe trajectory during the passing of other encountered ships in good and restricted visibility at sea is presented. The comparison of the safe ship control in collision situation: multi-step matrix non-cooperative and cooperative games, multi-stage positional non-cooperative and cooperative games have been introduced. The considerations have been illustrated with examples of computer simulation of the algorithms to determine safe of own ship trajectories in a navigational situation during passing of eight met ships.

  13. Local Safety Toolkit: Enabling safe communities of opportunity

    CSIR Research Space (South Africa)

    Holtmann, B

    2010-08-31

    Full Text Available remain inadequate to achieve safety. The Local Safety Toolkit supports a strategy for a Safe South Africa through the implementation of a model for a Safe Community of Opportunity. The model is the outcome of work undertaken over the course of the past...

  14. Are EU Banks Safe?

    NARCIS (Netherlands)

    R.J. Theissen (Roel)

    2013-01-01

    markdownabstract__Abstract__ What exactly are the rules banks are subject to, and are they fit for purpose? These are the two questions addressed in this book ‘Are EU banks safe?’ and its descriptive companion book ‘EU banking supervision’. The full rulebook on banks is difficult to find

  15. Combined SAFE/SNAP approach to safeguards evaluation

    International Nuclear Information System (INIS)

    Engi, D.; Chapman, L.D.; Grant, F.H.; Polito, J.

    1980-01-01

    The scope of a safeguards evaluation model can efficiently address one of two issues: (1) global safeguards effectiveness or (2) vulnerability analysis for individual scenarios. The Safeguards Automated Facility Evaluation (SAFE) focuses on the first issue, while the Safeguards Network Analysis Procedure (SNAP) is directed towards the second. A combined SAFE/SNAP approach to the problem of safeguards evaluation is described and illustrated through an example. 4 refs

  16. A Privacy Analysis of Google and Yandex Safe Browsing

    OpenAIRE

    Gerbet , Thomas; Kumar , Amrit; Lauradoux , Cédric

    2015-01-01

    Google and Yandex Safe Browsing are popular services included in many webbrowsers to prevent users from visiting phishing or malware website links. If Safe Browsing servicesprotect their users from losing private information, they also require that their servers receivebrowsing information on the very same users. In this paper, we present an analysis of Googleand Yandex Safe Browsing services from a privacy perspective. We quantify the privacy providedby these services by analyzing the possib...

  17. Safe handling of TBP and nitrates in the nuclear process industry

    International Nuclear Information System (INIS)

    Hyder, M.L.

    1994-07-01

    A laboratory and literature study was made of the reactions of tri-n-butyl phosphate (TBP) with nitric acid and nitrates. Its goal was to establish safe conditions for solvent extraction processes involving these chemicals. The damaging explosions at the Tomsk-7 PUREX plant in Russia graphically illustrated the potential hazard involved in such operations. The study has involved a review of prior and contemporary experiments, and new experiments to answer particular questions about these reactions. TBP extracts nitric acid and some metal nitrates from aqueous solutions. The resulting liquid contains both oxidant and reductant, and can react exothermically if heated sufficiently. Safe handling of these potentially reactive materials involves not only limiting the heat generated by the chemical reaction, but also providing adequate heat removal and venting. Specifically, the following recommendations are made to ensure safety: (1) tanks in which TBP-nitrate complexes are or may be present should be adequately vented to avoid pressurization. Data are supplied as a basis for adequacy; (2) chemically degraded TBP, or TBP that has sat a long time in the presence of acids or radiation, should be purified before use in solvent extraction; (3) evaporators in which TBP might be introduced should be operated at a controlled temperature, and their TBP content should be limited; (4) evaporator bottoms that may contain TBP should be cooled under conditions that ensure heat removal. Finally, process design should consider the potential for such reactions, and operators should be made aware of this potential, so that it is considered during training and process operation

  18. Safe corridors for K-wiring in phalangeal fractures

    Directory of Open Access Journals (Sweden)

    C Rex

    2015-01-01

    Conclusion: K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.

  19. Slope Monitoring using Total Station: What are the Challenges and ...

    African Journals Online (AJOL)

    Afeni

    equipment for measuring atmospheric conditions, pillar beacons (for transfer and ... for example, a solar energy (as shown in figure 4a) or a standby generator. ... If the point is not too high for a hydraulic water hose to reach, the prism can be ...

  20. Premiering SAFE for Safety Added Fuel Element - 15020

    International Nuclear Information System (INIS)

    Bhowmik, P.K.; Shamim, J.A.; Suh, K.Y.; Suh, K.S.

    2015-01-01

    The impact of the Fukushima accident has been the willingness to implement passive safety measures in reactor design and to simplify reactor design itself. Within this framework, a new fuel element, named SAFE (Safety Added Fuel Element) based on the concept of accident tolerant fuel, is presented. SAFE is a new type of fuel element cooled internally and externally by light water and with stainless steel as the cladding material. The removal of boron may trigger a series of changes which may simplify the system greatly. A simplified thermal analysis of SAFE shows that the fuel centerline temperature is well below the maximal limit during the normal operation of the plant

  1. Alcohol use and safe drinking

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001944.htm Alcohol use and safe drinking To use the sharing features on this page, please enable JavaScript. Alcohol use involves drinking beer, wine, or hard liquor. ...

  2. Dukovany NPP - Safely 16 TERA

    International Nuclear Information System (INIS)

    Vlcek, J.

    2008-01-01

    In this presentation increasing of power output of the Dukovany NPP is reviewed. To operate all Dukovany Units safely with the perspective of long-term operation (LTO) of 50 - 60 years it is proposed.

  3. Setting priorities for safe motherhood interventions in resource-scarce settings.

    Science.gov (United States)

    Prata, Ndola; Sreenivas, Amita; Greig, Fiona; Walsh, Julia; Potts, Malcolm

    2010-01-01

    Guide policy-makers in prioritizing safe motherhood interventions. Three models (LOW, MED, HIGH) were constructed based on 34 sub-Saharan African countries to assess the relative cost-effectiveness of available safe motherhood interventions. Cost and effectiveness data were compiled and inserted into the WHO Mother Baby Package Costing Spreadsheet. For each model we assessed the percentage in maternal mortality reduction after implementing all interventions, and optimal combinations of interventions given restricted budgets of US$ 0.50, US$ 1.00, US$ 1.50 per capital maternal health expenditures respectively for LOW, MED, and HIGH models. The most cost-effective interventions were family planning and safe abortion (fpsa), antenatal care including misoprostol distribution for postpartum hemorrhage prevention at home deliveries (anc-miso), followed by sepsis treatment (sepsis) and facility-based postpartum hemorrhage management (pph). The combination of interventions that avert the greatest number of maternal deaths should be prioritized and expanded to cover the greatest number of women at risk. Those which save the most number of lives in each model are 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for LOW; 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for MED; and 'fpsa, anc-miso, sepsis, eclampsia treatment, safe delivery' for HIGH settings. Safe motherhood interventions save a significant number of newborn lives.

  4. Cold Vacuum Drying facility heating, ventilation, and Air Conditioning system design description

    International Nuclear Information System (INIS)

    SINGH, G.

    2000-01-01

    This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), electrical power distribution system (including standby power), compressed air system, Chilled Water (CHW) system, drainage system, and other Cold Vacuum Drying (CVD) control systems not addressed in this SDD

  5. Vitamin D status, bone mineral density and mental health in young Australian women: the Safe-D study

    Directory of Open Access Journals (Sweden)

    Emma T. Callegari

    2015-11-01

    Full Text Available Background. Vitamin D deficiency has been associated with both poor bone health and mental ill-health. More recently, a number of studies have found individuals with depressive symptoms tend to have reduced bone mineral density. To explore the interrelationships between vitamin D status, bone mineral density and mental-ill health we are assessing a range of clinical, behavioural and lifestyle factors in young women (Part A of the Safe-D study. Design and methods. Part A of the Safe-D study is a cross-sectional study aiming to recruit 468 young females aged 16-25 years living in Victoria, Australia, through Facebook advertising. Participants are required to complete an extensive, online questionnaire, wear an ultra-violet dosimeter for 14 consecutive days and attend a study site visit. Outcome measures include areal bone mineral measures at the lumbar spine, total hip and whole body, as well as soft tissue composition using dual energy x-ray absorptiometry. Trabecular and cortical volumetric bone density at the tibia is measured using peripheral quantitative computed tomography. Other tests include serum 25-hydroxyvitamin D, serum biochemistry and a range of health markers. Details of mood disorder/s and depressive and anxiety symptoms are obtained by self-report. Cutaneous melanin density is measured by spectrophotometry. Expected impact. The findings of this cross-sectional study will have implications for health promotion in young women and for clinical care of those with vitamin D deficiency and/or mental ill-health. Optimising both vitamin D status and mental health may protect against poor bone health and fractures in later life.

  6. Computerized operator support system with new man-machine interface for BWR power plants

    International Nuclear Information System (INIS)

    Monta, K.; Naito, N.; Sugawara, M.; Sato, N.; Mori, N.; Tai, I.; Fukumoto, A.; Tsuchida, M.

    1984-01-01

    Improvement of the man-machine interface of nuclear power plants is an important contribution to the further enhancement of operational safety. In addition, recent advances in computer technology seem to offer the greatest opportunity to date for achieving improvement in the man-machine interface. The development of a computerized operator support system for BWRs has been undertaken since 1980 with the support of the Japanese Government. The conceptual design of this system is based on the role of the operators. The main functions are standby system management, disturbance analysis and post-trip operational guidance. The objective of the standby system management is to monitor the standby status of the engineered safety feature during normal operation to assure its proper functioning at the onset of emergency situations. The disturbance analysis system detects disturbances in the plant in their early stages and informs the plant operators about, for example, the cause of the disturbances, the plant status and possible propagations. Consequently, operators can take corrective actions to prevent unnecessary plant shutdown. The objective of the post trip operational guide is to support operators in diagnosis and corrective action after a plant trip. Its functions are to monitor the performance of the engineered safety feature, to identify the plant status and to guide the appropriate corrective action to achieve safe plant shutdown. The information from the computerized operator support system is supplied to operators through a colour CRT operator console. The authors have evaluated the performance of various new man-machine interfacing tools and proposed a new operator console design. A prototype system has been developed and verification/validation is proceeding with a BWR plant simulator. (author)

  7. SAFE-AXISYM, Stress Analysis of Axisymmetric Composite Structure by Finite Elements Method

    International Nuclear Information System (INIS)

    Cornell, D.C.

    1967-01-01

    1 - Nature of physical problem solved: SAFE-AXISYM is a program for the analysis of multi-material axisymmetric composite structures. It is designed for the analysis of heterogeneous structures such as reinforced and/or prestressed concrete vessels. The structure is assumed to be linearly elastic, and only bodies of revolution subjected to axisymmetric loading can be treated. 2 - Method of solution: SAFE-AXISYM uses a finite element method with a modified Gauss-Seidel iteration scheme. A reference grid subdivides the structure into ring-like small, finite elements, the vertices of which are called nodes. The grid may be generated by hand, by the computer or by a combination of the two methods. Each node has two degrees of freedom, translation in the and in the axial direction. Both zero and non-zero fixed displacement constraints may be assumed, and the loading condition may be mechanical and/or thermal. 3 - Restrictions on the complexity of the problem: Multi-material structures with varying rigidities converge very slowly. Not valid for incompressible materials. Maximum number of nodes = 475. Maximum number of elements = 1100

  8. How safe is safe?

    International Nuclear Information System (INIS)

    Hughes, C.F.; Flood, M.

    1996-01-01

    60 and 70 degree convexo-concave valve. Nine hundred and one valves were implanted in Australia. Twelve strut fractures were reported. Two other patients have been explanted and have demonstrated 'single leg separation'. This particular problem was only investigated when two patients died of a fractured valve in the same hospital on the same day. A retrospective study of all known patients in Australia has shown poor follow up, lack of knowledge and indeed lack of interest in device failure modes. Consequently, the Australian and New Zealand Heart Valve Registry was established to track all implanted valves and to notify physicians of any new information. This is perhaps the first device-specific register in Australia. The safety of individual devices is often not known by manufacturers, regulators and clinicians alike. No follow up is available and large volume long term studies are yet to be implemented for the majority of devices. Without such studies and without mandatory problem reporting, the relative safety of medical devices will continue to be measured by banner headlines, sensational TV 'grabs' and protracted law suits. At present, only schemes such as the Problem Reporting Scheme can tell us (albeit vaguely) 'how safe is safe'

  9. Safe motherhood at risk?

    Science.gov (United States)

    Thompson, A

    1996-12-01

    Health professionals' negative attitudes toward clients often exacerbate the problems women face in terms of health status and access to health care. Thus, the health professionals can themselves be obstacles to women seeking the health care they need. A key challenge to midwives, in addition to providing technically competent services, is gaining insight into the people for whom they are responsible so that childbirth traditions are treated with respect and women are offered dignity. Safe motherhood requires intersectoral collaboration. Many innovative approaches to safe motherhood are based on the community's participation in planning services that meet the needs of women. Other approaches are based on decentralization of services. For example, a large university teaching hospital in Lusaka, Zambia, set up birthing centers around the city to take the pressure off the hospital. Midwives head up these centers, which are close to the women's homes. Decentralization of delivery services has improved the physical and emotional outcomes for mothers and newborns. Midwives must be prepared to articulate concerns about inequalities and deficiencies in the health care system in order to persuade the government to change. Women, including midwives, need to form multidisciplinary alliances to work together to effect change. The front-line workers in maternity care are midwives. They should adopt the following strategies to become even more effective in their efforts to make motherhood safer. They should listen to what women say about their needs. They should scale services to a manageable, human scale. They should learn the skills to become politically active advocates. They should work with other midwives, women, leaders, and other professional groups. Motherhood can be safe when women have more control over their own decision making, the education to liberate themselves to make their own decisions, and access to skilled care.

  10. Reducing Leaking Electricity to 1 Watt

    Energy Technology Data Exchange (ETDEWEB)

    Meier, A.K.; Huber, Wolfgang; Rosen, Karen

    1998-08-01

    In this study we examine some specific opportunities toreduce standby losses in electronic appliances. A review of powerconsumption levels for the major components responsible for standbyfunctions indicates that nearly all standby functions can be performedwith a total appliance standby power consumption of one watt or less. Wetherefore propose that standby losses be limited to one watt perappliance, a significant reduction from current levels for manyappliances. This target could be achieved with little or no extra cost tomanufacturers and could save over $2 billion in annual U.S. energy costs.Globally, a one-watt plan would lead to a significant reduction in carbonemissions.

  11. State of the art undersøgelse

    DEFF Research Database (Denmark)

    Nielsen, Nils

    1998-01-01

    Dette skrift omhandler nogle af de erfaringer der til dato er opnået i forbindelse med standby projektets udførelse. Hovedtemaet er en “State of the art undersøgelse” der omhandler standby-spændingsforsyninger, samt komponenter der kan anvendes til konstruktion af dem......Dette skrift omhandler nogle af de erfaringer der til dato er opnået i forbindelse med standby projektets udførelse. Hovedtemaet er en “State of the art undersøgelse” der omhandler standby-spændingsforsyninger, samt komponenter der kan anvendes til konstruktion af dem...

  12. Method for the conditioning of high level radioactive wastes for their safe storage and disposal

    International Nuclear Information System (INIS)

    Geel, J. van; Eschrich, H.; Detilleux, E.

    1976-01-01

    A method is described for the treatment of solidified high level radioactive wastes to enable them to be safely stored or disposed of in an approved manner. The solidified waste is embedded in a matrix of pure metals or metal alloys. The metals may be Pb, Pb/Sb alloys, Pb/Sn alloys, Pb/Bi alloys, Pb/Zn alloys, or mixtures of these, or Al, Al/Si alloys, Al/Mg alloys, Al/Cu alloys, or mixtures. The matrix is clad with non-corrosive material, selected from stainless steel, Ti, Pb, Pb alloys, Al, Al alloys, or mixtures of same. A non-corrosive container is filled with the solidified waste and is heated to above the melting temperature of the metallic matrix material used to embed the waste. The matrix material is then added and the container is cooled. The container may then be degassed. The solidified waste feed may be in the form of a vitreous material containing the high level waste; this vitreous material may consist of a lead borosilicate or a mixture of non-lead borosilicates and phosphate glasses, and the method of preparing it is described. (U.K.)

  13. Methodology applied in Cuba for siting, designing, and building a radioactive waste repository under safety conditions

    International Nuclear Information System (INIS)

    Orbera, L.; Peralta, J.L.; Franklin, R.; Gil, R.; Chales, G.; Rodriguez, A.

    1993-01-01

    The work presents the methodology used in Cuba for siting, designing, and building a radioactive waste repository safely. This methodology covers both the technical and socio-economic factors, as well as those of design and construction so as to have a safe siting for this kind of repository under Cuba especial condition. Applying this methodology will results in a safe repository

  14. Evaluation of warm mix asphalt for Alaska conditions : [summary].

    Science.gov (United States)

    2010-09-01

    This project developed and tested protocols to determine concrete curing strength during the construction process, so that : building under very cold conditions can be performed safely and quickly. Researchers determined the laboratory strengthmaturi...

  15. Assessment methodology applicable to safe decommissioning of Romanian VVR-S research reactor

    International Nuclear Information System (INIS)

    Baniu, O.; Vladescu, G.; Vidican, D.; Penescu, M.

    2002-01-01

    The paper contains the results of research activity performed by CITON specialists regarding the assessment methodology intended to be applied to safe decommissioning of the research reactors, developed taking into account specific conditions of the Romanian VVR-S Research Reactor. The Romanian VVR-S Research Reactor is an old reactor (1957) and its Decommissioning Plan is under study. The main topics of paper are as follows: Safety approach of nuclear facilities decommissioning. Applicable safety principles; Main steps of the proposed assessment methodology; Generic content of Decommissioning Plan. Main decommissioning activities. Discussion about the proposed Decommissioning Plan for Romanian Research Reactor; Safety risks which may occur during decommissioning activities. Normal decommissioning operations. Fault conditions. Internal and external hazards; Typical development of a scenario. Features, Events and Processes List. Exposure pathways. Calculation methodology. (author)

  16. Standards for safe operation of research reactors

    International Nuclear Information System (INIS)

    1996-01-01

    The safety of research reactors is based on many factors such as suitable choice of location, design and construction according to the international standards, it also depends on well trained and qualified operational staff. These standards determine the responsibilities of all who are concerned with the research reactors safe operation, and who are responsible of all related activities in all the administrative and technical stages in a way that insures the safe operation of the reactor

  17. Asymptotically Safe Standard Model Extensions arXiv

    CERN Document Server

    Pelaggi, Giulio Maria; Salvio, Alberto; Sannino, Francesco; Smirnov, Juri; Strumia, Alessandro

    We consider theories with a large number NF of charged fermions and compute the renormalisation group equations for the gauge, Yukawa and quartic couplings resummed at leading order in NF. We construct extensions of the Standard Model where SU(2) and/or SU(3) are asymptotically safe. When the same procedure is applied to the Abelian U(1) factor, we find that the Higgs quartic can not be made asymptotically safe and stay perturbative at the same time.

  18. Licensing issues for inherently safe fast reactors

    International Nuclear Information System (INIS)

    Kastenberg, W.E.; Lee, S.; Okrent, D.

    1986-01-01

    There has been considerable interest recently in a new generation of liquid metal reactor (LMR) concepts in the US. Some significant changes in regulatory philosophy will be required if the anticipated cost advantages of inherently safe designs are to be achieved. The defense in depth philosophy will need to be significantly re-evaluated in the context of inherently safe reactors. It is the purpose of this paper to begin such a re-evaluation of this regulatory philosophy

  19. arXiv Asymptotically Safe Standard Model Extensions?

    CERN Document Server

    Pelaggi, Giulio Maria; Salvio, Alberto; Sannino, Francesco; Smirnov, Juri; Strumia, Alessandro

    2018-05-15

    We consider theories with a large number NF of charged fermions and compute the renormalization group equations for the gauge, Yukawa and quartic couplings resummed at leading order in 1/NF. We construct extensions of the standard model where SU(2) and/or SU(3) are asymptotically safe. When the same procedure is applied to the Abelian U(1) factor, we find that the Higgs quartic can not be made asymptotically safe and stay perturbative at the same time.

  20. Examination of a University-Affiliated Safe Ride Program

    Science.gov (United States)

    Gieck, D. Joseph; Slagle, David M.

    2010-01-01

    A university-affiliated safe ride program was evaluated to determine whether these programs can reduce drunk-driving related costs. Data was collected from 187 safe ride passengers during three nights of operation. Among the passengers, 93% were enrolled at a local University, 31% were younger than 21, and 40% reported a prior alcohol-related…

  1. Safe drinking during cancer treatment

    Science.gov (United States)

    ... ency/patientinstructions/000060.htm Drinking water safely during cancer treatment To use the sharing features on this page, please enable JavaScript. During and right after your cancer treatment, your body may not be able to protect ...

  2. Implications of inherent safe nuclear power system

    International Nuclear Information System (INIS)

    Song, Yo-Taik

    1987-01-01

    The safety of present day nuclear power reactors and research reactors depends on a combination of design features of passive and active systems, and the alert judgement of their operators. A few inherently safe designs of nuclear reactors for power plants are currently under development. In these designs, the passive systems are emphasized, and the active systems are minimized. Also efforts are made to eliminate the potential for human failures that initiate the series of accidents. If a major system fails in these designs, the core is flooded automatically with coolants that flow by gravity, not by mechanical pumps or electromagnetic actuators. Depending on the choice of the coolants--water, liquid metal and helium gas--there are three principal types of inherently safe reactors. In this paper, these inherently safe reactor designs are reviewed and their implications are discussed. Further, future perspectives of their acceptance by nuclear industries are discussed. (author)

  3. Landscape planning for a safe city

    Directory of Open Access Journals (Sweden)

    M. Ishikawa

    2002-06-01

    Full Text Available To create a safe city free from natural disasters has been one of the important criteria in city planning. Since large cities have suffered from large fires caused by earthquakes, the planning of open spaces to prevent the spread of fires is part of the basic structure of city planning in Japan. Even in the feudal city of Edo, the former name of Tokyo, there had been open spaces to prevent fire disasters along canals and rivers. This paper discusses the historical evolution of open space planning, that we call landscape planning, through the experiences in Tokyo, and clarifies the characteristics and problems for achieving a safe city.

  4. 1998 FFTF annual system assessment reports

    International Nuclear Information System (INIS)

    Guttenberg, S.

    1998-01-01

    The health of FFTF systems was assessed assuming a continued facility standby condition. The review was accomplished in accordance with the guidelines of FFTF-EI-083, Plant Evaluation Program. The attached document includes an executive summary of the significant conclusions and assessment reports for each system evaluated

  5. 1998 FFTF annual system assessment reports

    Energy Technology Data Exchange (ETDEWEB)

    Guttenberg, S.

    1998-03-19

    The health of FFTF systems was assessed assuming a continued facility standby condition. The review was accomplished in accordance with the guidelines of FFTF-EI-083, Plant Evaluation Program. The attached document includes an executive summary of the significant conclusions and assessment reports for each system evaluated.

  6. Swimming Safely (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2014-05-22

    In the summertime, families will be flocking to pools for relaxation and relief from the heat. A few simple precautions can help ensure a safe day in the water. In this podcast, Michele Hlavsa discusses ways to stay safe at the pool.  Created: 5/22/2014 by MMWR.   Date Released: 5/22/2014.

  7. Reactor internals design/analysis for normal, upset, and faulted conditions

    International Nuclear Information System (INIS)

    Burke, F.R.

    1977-06-01

    The analytical procedures used by Babcock and Wilcox to demonstrate the structural integrity of the 205-FA reactor internals are described. Analytical results are presented and compared to ASME Code allowable limits for Normal, Upset, and Faulted conditions. The particular faulted condition considered is a simultaneous loss-of-coolant accident and safe shutdown earthquake. The operating basis earthquake is addressed as an Upset condition

  8. Gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of malaysia.

    Science.gov (United States)

    Bin Nordin, R; Araki, S; Sato, H; Yokoyama, K; Bin Wan Muda, W A; Win Kyi, D

    2001-01-01

    To identify gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of Malaysia, we conducted a 20-item questionnaire interview on storage of pesticide (4 questions), mixing of pesticide (3 questions), use of personal protective equipment and clothing while spraying pesticide (7 questions), activities during and after spraying of pesticide (5 questions), and maintenance of pesticide sprayer (1 question) in 496 tobacco farmers (395 males and 101 females) in Bachok District, Kelantan, Malaysia. Duration of employment was significantly longer in females than those in males (pwork habit, (3) reading and following instructions on pesticide label, (4) security, storage and disposal of pesticide container, (5) safe work habit, (6) proper handling of pesticide and maintenance of pesticide sprayer, (7) use of personal protective clothing, and (8) safe handling of pesticide. Results of analysis of covariance for the eight factor scores of all male and female farmers, controlling for educational level and duration of employment, showed that: (1) factor scores for use of personal protective equipment (pwork habit (p0.05). We therefore conclude that: (1) for female tobacco farmers, choice of personal attire tend to result in lower scores on use of personal protective equipment and personal protective clothing while personal hygiene practices result in lower score on safe work habit; and, (2) for male tobacco farmers, the lower scores on reading and following instruction on pesticide label and mixing pesticide and maintenance of pesticide sprayer in good condition suggests that they were not primarily involved in these activities. It is postulated that these differences in safe and unsafe practices of pesticide handling across gender is related to the choice of personal attire, personal hygiene practices and division of labour within farming households which in turn is influenced by prevailing sociocultural norms in the community.

  9. Indoor Tanning Is Not Safe

    Science.gov (United States)

    ... the sun is by using these tips for skin cancer prevention. Indoor tanning is not a safe way to get vitamin ... to previous findings on the association between indoor tanning and skin cancer. Only a small number of people reported ...

  10. Staying Safe on the Water

    Centers for Disease Control (CDC) Podcasts

    2008-06-05

    In this podcast for all audiences, Dr. Julie Gilchrist from CDC's Injury Center outlines tips for safe boating.  Created: 6/5/2008 by National Center for Injury Prevention and Control (NCIPC).   Date Released: 6/8/2008.

  11. International conference on safe decommissioning for nuclear activities: Assuring the safe termination of practices involving radioactive materials. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    Thousands of operations involving the use of radioactive substances will end during the current century. While there is considerable regulatory experience in the 'front end' of the regulatory system for practices, the experience at the back end is more limited as fewer practices have actually been terminated. When a practice is terminated because the facility has reached the end of its useful life, action has to betaken to ensure the safe shutdown of the facility and allow the removal of regulatory controls. There are many issues involved in the safe termination of practices. These include setting criteria for the release of material and sites from regulatory control; determining the suitability of the various options for decommissioning nuclear facilities, managing the waste and material released from control (recycling, reuse or disposal), and the eventual remediation of the site. Some countries have put in place regulatory infrastructures and have developed programmes to manage the associated decommissioning and remediation activities. Other countries are at the stage of assessing what is involved in terminating such practices. The purpose of this Conference is to foster an information exchange on the safe an orderly termination of practices that involve the use of radioactive substances, including both decommissioning and environmental remediation, and to promote improved coherence internationally on strategies and criteria for the safe termination of practices.

  12. International conference on safe decommissioning for nuclear activities: Assuring the safe termination of practices involving radioactive materials. Contributed papers

    International Nuclear Information System (INIS)

    2002-01-01

    Thousands of operations involving the use of radioactive substances will end during the current century. While there is considerable regulatory experience in the 'front end' of the regulatory system for practices, the experience at the back end is more limited as fewer practices have actually been terminated. When a practice is terminated because the facility has reached the end of its useful life, action has to betaken to ensure the safe shutdown of the facility and allow the removal of regulatory controls. There are many issues involved in the safe termination of practices. These include setting criteria for the release of material and sites from regulatory control; determining the suitability of the various options for decommissioning nuclear facilities, managing the waste and material released from control (recycling, reuse or disposal), and the eventual remediation of the site. Some countries have put in place regulatory infrastructures and have developed programmes to manage the associated decommissioning and remediation activities. Other countries are at the stage of assessing what is involved in terminating such practices. The purpose of this Conference is to foster an information exchange on the safe an orderly termination of practices that involve the use of radioactive substances, including both decommissioning and environmental remediation, and to promote improved coherence internationally on strategies and criteria for the safe termination of practices

  13. Reliability optimization of series–parallel systems with mixed redundancy strategy in subsystems

    International Nuclear Information System (INIS)

    Abouei Ardakan, Mostafa; Zeinal Hamadani, Ali

    2014-01-01

    Traditionally in redundancy allocation problem (RAP), it is assumed that the redundant components are used based on a predefined active or standby strategies. Recently, some studies consider the situation that both active and standby strategies can be used in a specific system. However, these researches assume that the redundancy strategy for each subsystem can be either active or standby and determine the best strategy for these subsystems by using a proper mathematical model. As an extension to this assumption, a novel strategy, that is a combination of traditional active and standby strategies, is introduced. The new strategy is called mixed strategy which uses both active and cold-standby strategies in one subsystem simultaneously. Therefore, the problem is to determine the component type, redundancy level, number of active and cold-standby units for each subsystem in order to maximize the system reliability. To have a more practical model, the problem is formulated with imperfect switching of cold-standby redundant components and k-Erlang time-to-failure (TTF) distribution. As the optimization of RAP belongs to NP-hard class of problems, a genetic algorithm (GA) is developed. The new strategy and proposed GA are implemented on a well-known test problem in the literature which leads to interesting results. - Highlights: • In this paper the redundancy allocation problem (RAP) for a series–parallel system is considered. • Traditionally there are two main strategies for redundant component namely active and standby. • In this paper a new redundancy strategy which is called “Mixed” redundancy strategy is introduced. • Computational experiments demonstrate that implementing the new strategy lead to interesting results

  14. Beyond Safe Operating Space: Finding Chemical Footprinting Feasible

    DEFF Research Database (Denmark)

    Posthuma, Leo; Bjørn, Anders; Zijp, Michiel C.

    2014-01-01

    undefined boundary in their selection of planetary boundaries delineating the “safe operating space for humanity”. Can we use the well-known concept of “ecological footprints” to express a chemical pollution boundary aimed at preventing the overshoot of the Earth’s capacity to assimilate environmental...... scenarios that allow us to avoid “chemical overshoot” beyond the Earth’s safe operating space....

  15. [Anniversary of the medical department of the Federal Office for Safe Storage and Destruction of Chemical Weapons].

    Science.gov (United States)

    Kuz'menko, I E

    2013-01-01

    The article is devoted to the process of formation and development of CW destruction management system and medical support of professional activities of personnel. Founders of Medical department of the Federal Directorate for Safe Storage and Destruction of Chemical Weapons are presented. Main principles and ways of working of medical department in specific conditions are covered.

  16. Safe handling of tritium

    International Nuclear Information System (INIS)

    1991-01-01

    The main objective of this publication is to provide practical guidance and recommendations on operational radiation protection aspects related to the safe handling of tritium in laboratories, industrial-scale nuclear facilities such as heavy-water reactors, tritium removal plants and fission fuel reprocessing plants, and facilities for manufacturing commercial tritium-containing devices and radiochemicals. The requirements of nuclear fusion reactors are not addressed specifically, since there is as yet no tritium handling experience with them. However, much of the material covered is expected to be relevant to them as well. Annex III briefly addresses problems in the comparatively small-scale use of tritium at universities, medical research centres and similar establishments. However, the main subject of this publication is the handling of larger quantities of tritium. Operational aspects include designing for tritium safety, safe handling practice, the selection of tritium-compatible materials and equipment, exposure assessment, monitoring, contamination control and the design and use of personal protective equipment. This publication does not address the technologies involved in tritium control and cleanup of effluents, tritium removal, or immobilization and disposal of tritium wastes, nor does it address the environmental behaviour of tritium. Refs, figs and tabs

  17. Rapid Prototyping High-Performance MR Safe Pneumatic Stepper Motors

    NARCIS (Netherlands)

    Groenhuis, Vincent; Stramigioli, Stefano

    2018-01-01

    In this paper we show that pneumatic stepper motors for MR safe robots can be constructed using rapid prototyping techniques such as 3-D printing and laser-cutting. The designs are lightweight, completely metal-free and fully customizable. Besides MR safe robotic systems, other potential

  18. Short-term pressure and temperature MSLB response analyses for large dry containment of the Maanshan nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Liang-Che, E-mail: lcdai@iner.gov.tw; Chen, Yen-Shu; Yuann, Yng-Ruey

    2014-12-15

    Highlights: • The GOTHIC code is used for the PWR dry containment pressure and temperature analysis. • Boundary conditions are hot standby and 102% power main steam line break accidents. • Containment pressure and temperature responses of GOTHIC are similar with FSAR. • The capability of the developed model to perform licensing calculation is assessed. - Abstract: Units 1 and 2 of the Maanshan nuclear power station are the typical Westinghouse three-loop PWR (pressurized water reactor) with large dry containments. In this study, the containment analysis program GOTHIC is adopted for the dry containment pressure and temperature analysis. Free air space and sump of the PWR dry containment are individually modeled as control volumes. The containment spray system and fan cooler unit are also considered in the GOTHIC model. The blowdown mass and energy data of the main steam line break (hot standby condition and various reactor thermal power levels) are tabulated in the Maanshan Final Safety Analysis Report (FSAR) 6.2 which could be used as the boundary conditions for the containment model. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR results. In this study, hot standby and 102% reactor thermal power main steam line break accidents are selected. The calculated peak containment pressure is 323.50 kPag (46.92 psig) for hot standby MSLB, which is a little higher than the FSAR value of 311.92 kPag (45.24 psig). But it is still below the design value of 413.69 kPag (60 psig). The calculated peak vapor temperature inside the containment is 187.0 °C (368.59 F) for 102% reactor thermal power MSLB, which is lower than the FSAR result of 194.42 °C (381.95 F). The effects of the containment spray system and fan cooler units could be clearly observed in the GOTHIC analysis. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR

  19. Short-term pressure and temperature MSLB response analyses for large dry containment of the Maanshan nuclear power station

    International Nuclear Information System (INIS)

    Dai, Liang-Che; Chen, Yen-Shu; Yuann, Yng-Ruey

    2014-01-01

    Highlights: • The GOTHIC code is used for the PWR dry containment pressure and temperature analysis. • Boundary conditions are hot standby and 102% power main steam line break accidents. • Containment pressure and temperature responses of GOTHIC are similar with FSAR. • The capability of the developed model to perform licensing calculation is assessed. - Abstract: Units 1 and 2 of the Maanshan nuclear power station are the typical Westinghouse three-loop PWR (pressurized water reactor) with large dry containments. In this study, the containment analysis program GOTHIC is adopted for the dry containment pressure and temperature analysis. Free air space and sump of the PWR dry containment are individually modeled as control volumes. The containment spray system and fan cooler unit are also considered in the GOTHIC model. The blowdown mass and energy data of the main steam line break (hot standby condition and various reactor thermal power levels) are tabulated in the Maanshan Final Safety Analysis Report (FSAR) 6.2 which could be used as the boundary conditions for the containment model. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR results. In this study, hot standby and 102% reactor thermal power main steam line break accidents are selected. The calculated peak containment pressure is 323.50 kPag (46.92 psig) for hot standby MSLB, which is a little higher than the FSAR value of 311.92 kPag (45.24 psig). But it is still below the design value of 413.69 kPag (60 psig). The calculated peak vapor temperature inside the containment is 187.0 °C (368.59 F) for 102% reactor thermal power MSLB, which is lower than the FSAR result of 194.42 °C (381.95 F). The effects of the containment spray system and fan cooler units could be clearly observed in the GOTHIC analysis. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR

  20. FAST: towards safe and effective subcutaneous immunotherapy of persistent life-threatening food allergies

    Directory of Open Access Journals (Sweden)

    Zuidmeer-Jongejan Laurian

    2012-03-01

    Full Text Available Abstract The FAST project (Food Allergy Specific Immunotherapy aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT, using subcutaneous injections with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused by a single major allergen, parvalbumin (Cyp c 1 and lipid transfer protein (Pru p 3, respectively. Two approaches are being evaluated for achieving hypoallergenicity, i.e. site-directed mutagenesis and chemical modification. The most promising hypoallergens will be produced under GMP conditions. After pre-clinical testing (toxicology testing and efficacy in mouse models, SCIT with alum-absorbed hypoallergens will be evaluated in phase I/IIa and IIb randomized double-blind placebo-controlled (DBPC clinical trials, with the DBPC food challenge as primary read-out. To understand the underlying immune mechanisms in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold for fish or peach intake, thereby decreasing their anxiety and dependence on rescue medication.

  1. FAST: towards safe and effective subcutaneous immunotherapy of persistent life-threatening food allergies

    Science.gov (United States)

    2012-01-01

    The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused by a single major allergen, parvalbumin (Cyp c 1) and lipid transfer protein (Pru p 3), respectively. Two approaches are being evaluated for achieving hypoallergenicity, i.e. site-directed mutagenesis and chemical modification. The most promising hypoallergens will be produced under GMP conditions. After pre-clinical testing (toxicology testing and efficacy in mouse models), SCIT with alum-absorbed hypoallergens will be evaluated in phase I/IIa and IIb randomized double-blind placebo-controlled (DBPC) clinical trials, with the DBPC food challenge as primary read-out. To understand the underlying immune mechanisms in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold for fish or peach intake, thereby decreasing their anxiety and dependence on rescue medication. PMID:22409908

  2. Microbial ecology of artisanal Italian Cheese: environment and working conditions

    International Nuclear Information System (INIS)

    Dioguardi, L.; Colombo, E.; Franzetti, L.

    2009-01-01

    In agro-food sector the structural features of working environments and consequently their hygienic conditions are of primary importance for a safe and quality food production and to ensure comfortable and ergonomic working conditions. In particular, as regards high-mountain dairy production, the environment is important because it can affect the development of typical microbial ecosystem. (Author)

  3. Microbial ecology of artisanal Italian Cheese: environment and working conditions

    Energy Technology Data Exchange (ETDEWEB)

    Dioguardi, L.; Colombo, E.; Franzetti, L.

    2009-07-01

    In agro-food sector the structural features of working environments and consequently their hygienic conditions are of primary importance for a safe and quality food production and to ensure comfortable and ergonomic working conditions. In particular, as regards high-mountain dairy production, the environment is important because it can affect the development of typical microbial ecosystem. (Author)

  4. STRRAP system-A software for hazardous materials risk assessment and safe distances calculation

    International Nuclear Information System (INIS)

    Godoy, S.M.; Santa Cruz, A.S.M.; Scenna, N.J.

    2007-01-01

    This work presents a powerful computational tool (Stochastic Toxic Release Risk Assessment Package, STRRAP) useful in risk assessment and emergency planning (safe distance calculation), which allows to handle the stochastic uncertainty of atmospheric parameters, critical for risk calculation when diffusion of hazardous gases or particulate matter occur as a consequence of an emission or accidental release. In fact, the random behaviour of wind intensity, wind direction, atmospheric stability and temperature, given a time horizon, (a season or a complete year), is taken into account considering also the day or night condition. STRRAP can be used for releases or emissions from static sources (for example a stack or a fixed tank in a facility) or from transportation accidents (road, rail, maritime and pipeline transport) involving different scenarios. After a stochastic simulation based on well-known diffusion models (dense and light gases, particulate matter) is carried out, the downwind pollutant concentrations are obtained, in order to compute safe distances and/or individual and societal risks. Some study cases are analyzed to show STRRAP capabilities

  5. Malaria prevention strategies and recommendations, from chemoprophylaxis to stand-by emergency treatment: a 10-year prospective study in a Swiss Travel Clinic.

    Science.gov (United States)

    Boubaker, Rim; Hérard Fossati, Annie; Meige, Pierrette; Mialet, Catherine; Ngarambe Buffat, Chantal; Rochat, Jacynthe; Souvannaraj-Blanchant, Manisinh; Uwanyiligira, Mediatrice; Widmer, Francine; Payot, Sylvie; Rochat, Laurence; de Vallière, Serge; D'Acremont, Valérie; Genton, Blaise

    2017-09-01

    There are several possible malaria prevention strategies for travellers. In Switzerland, chemoprophylaxis (CP) is recommended for persons visiting areas highly endemic for malaria and stand-by emergency treatment (SBET) for areas with moderate to low risk. To describe the type of malaria prevention prescribed to travel clinic attendees with a specific focus on changes over time following adaptation of recommendations. All pre-travel first consultation data recorded between November 2002 and December 2012 were included. Country-specific malaria preventive recommendations provided and medicines prescribed over time were analysed. In total, 64 858 client-trips were recorded. 91% of travellers planned to visit a malaria endemic country. Among those clients, 42% were prescribed an antimalarial medicine as CP only, 36% as SBET only, and 3% both. Between 2002 and 2012, there was a 16% drop of CP prescription ( P  travellers receiving CP, the proportion of those prescribed mefloquine dropped from 82% in 2002 to 46% in 2012 while those prescribed atovaquone-proguanil (AP) increased from 7% to 39%. For those prescribed SBET, the proportion dropped from 46% to 30% for AP and increased from 2% to 61% for artemether-lumefantrine. CP prescription for travellers to India fell from 62% to 5% and SBET prescription increased from 40% to 88% after the change of recommendation from CP to SBET in 2005 for this country. Comparatively, CP prescription for travellers to Senegal, for which no change of recommendation occurred, remained relatively stable between 88% in 2002 and 89% in 2012. This study shows the considerable decline of antimalarial prescription for chemoprophylaxis that occurred over the 10-year period in favour of SBET. © International Society of Travel Medicine, 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  6. Safe Use of Contrast Media: What the Radiologist Needs to Know.

    Science.gov (United States)

    Beckett, Katrina R; Moriarity, Andrew K; Langer, Jessica M

    2015-10-01

    Iodinated and gadolinium-based contrast media are used on a daily basis in most radiology practices. These agents often are essential to providing accurate diagnoses, and are nearly always safe and effective when administered correctly. However, reactions to contrast media do occur and can be life threatening. Therefore, it is critical for faculty and staff to know how reactions to contrast agents manifest and how to treat them promptly. The decline in renal function seen occasionally after intravenous administration of iodinated contrast agents is poorly understood and likely multifactorial, and its association with the contrast medium may be overemphasized. However, it is important that radiologists be aware of current understanding and strategies to decrease the incidence of renal dysfunction. Nephrogenic systemic fibrosis, a skin disease, is an adverse reaction related to use of some gadolinium-based contrast agents in patients with chronic renal failure. The types of gadolinium most often associated with this condition and the indications for withholding gadolinium are important and are discussed in this article. The use of enteric contrast agents and contrast agents during pregnancy and nursing are reviewed briefly. Current knowledge for safe use of contrast media and key concepts that all radiologists should know are summarized in this review. © RSNA, 2015.

  7. Thermodynamics of asymptotically safe theories

    DEFF Research Database (Denmark)

    Rischke, Dirk H.; Sannino, Francesco

    2015-01-01

    We investigate the thermodynamic properties of a novel class of gauge-Yukawa theories that have recently been shown to be completely asymptotically safe, because their short-distance behaviour is determined by the presence of an interacting fixed point. Not only do all the coupling constants freeze...

  8. How Safe Are Our Libraries?

    Science.gov (United States)

    St. Lifer, Evan

    1994-01-01

    Addresses issues of safety and security in libraries. Topics discussed include keeping library collections safe; patron behavioral problems; factoring loss into the budget; staff theft; access versus security; apathy regarding library crime; a need for a unified security apparatus; preventive measures; staff and patron safety; and a…

  9. Maintaining access to safe abortion and reducing sex ratio imbalances in Asia.

    Science.gov (United States)

    Ganatra, Bela

    2008-05-01

    High sex ratios at birth (108 boys to 100 girls or higher) are seen in China, Taiwan, South Korea and parts of India and Viet Nam. The imbalance is the result of son preference, accentuated by declining fertility. Prenatal sex detection with ultrasound followed by second trimester abortion is one of the ways sex selection manifests itself, but it is not the causative factor. Advocates and governments seeking to reverse this imbalance have largely prohibited sex detection tests and/or sex selective abortion, assuming these measures would reverse the trend. Such policies have been difficult to enforce and have met with only limited success. At the same time, such policies are starting to have adverse effects on the already limited access to safe and legal second trimester abortion for reasons other than sex selection. Moreover, the sex selection issue is being used as a platform for anti-abortion rhetoric by certain groups. Maintaining access to safe abortion and achieving a decline in high sex ratios are both important goals. Both are possible if the focus shifts to addressing the conditions that drive son preference.

  10. Patient Involvement in Safe Delivery: A Qualitative Study

    OpenAIRE

    Olfati, Forozun; Asefzadeh, Saeid; Changizi, Nasrin; Keramat, Afsaneh; Yunesian, Masud

    2015-01-01

    Introduction: Patient involvement in safe delivery planning is considered important yet not widely practiced. The present study aimed at identifythe factors that affect patient involvementin safe delivery, as recommended by parturient women. Methods: This study was part of a qualitative research conducted by content analysis method and purposive sampling in 2013. The data were collected through 63 semi-structured interviews in4 hospitalsand analyzed using thematic content analysis. The partic...

  11. Safe transport of radioactive materials in Egypt

    International Nuclear Information System (INIS)

    El-Shinawy, R.M.K.

    1994-01-01

    In Egypt the national regulations for safe transport of radioactive materials (RAM) are based on the International Atomic Energy Agency (IAEA) regulations. In addition, regulations for the safe transport of these materials through the Suez Canal (SC) were laid down by the Egyptian Atomic Energy Authority (EAEA) and the Suez Canal Authority (SCA). They are continuously updated to meet the increased knowledge and the gained experience. The technical and protective measures taken during transport of RAM through SC are mentioned. Assessment of the impact of transporting radioactive materials through the Suez Canal using the INTERTRAN computer code was carried out in cooperation with IAEA. The transported activities and empty containers, the number of vessels carrying RAM through the canal from 1963 and 1991 and their nationalities are also discussed. The protective measures are mentioned. A review of the present situation of the radioactive wastes storage facilities at the Atomic Energy site at Inshas is given along with the regulation for safe transportation and disposal of radioactive wastes. (Author)

  12. 42 CFR 416.44 - Condition for coverage-Environment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Condition for coverage-Environment. 416.44 Section... for coverage—Environment. The ASC must have a safe and sanitary environment, properly constructed, equipped, and maintained to protect the health and safety of patients. (a) Standard: Physical environment...

  13. Reactive, Safe Navigation for Lunar and Planetary Robots

    Science.gov (United States)

    Utz, Hans; Ruland, Thomas

    2008-01-01

    When humans return to the moon, Astronauts will be accompanied by robotic helpers. Enabling robots to safely operate near astronauts on the lunar surface has the potential to significantly improve the efficiency of crew surface operations. Safely operating robots in close proximity to astronauts on the lunar surface requires reactive obstacle avoidance capabilities not available on existing planetary robots. In this paper we present work on safe, reactive navigation using a stereo based high-speed terrain analysis and obstacle avoidance system. Advances in the design of the algorithms allow it to run terrain analysis and obstacle avoidance algorithms at full frame rate (30Hz) on off the shelf hardware. The results of this analysis are fed into a fast, reactive path selection module, enforcing the safety of the chosen actions. The key components of the system are discussed and test results are presented.

  14. Procedures for the Safe Transport of Radioactive Material

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Lyul; Chung, K. K.; Lee, J. I.; Chang, S. Y.; Lee, T. Y

    2007-11-15

    This technical report describes the procedure and work responsibility along with the regulation and standard necessary for the safe transport of radioactive or contaminated materials. This report, therefore, can be effectively used to secure the public safety as well as to prevent the disastrous event which might be resulted from the transport process of radioactive materials by establishing a procedure and method on the safe packing, handling and transport of radioactive materials.

  15. Part A: Countermeasures to be taken after 1990 to ensure safe living conditions for the population affected by the Chernobyl accident in the USSR. A first evaluation of costs and doses averted

    International Nuclear Information System (INIS)

    Lochard, J.; Schneider, T.

    1992-01-01

    This part presents a first estimate of the cost and averted collective exposure of the potential relocation of the population from the affected territories of the BSSR, the RSFSR and the UKrSSR, to improve their living conditions following the Chernobyl accident. It is an input to the evaluation of the radiological consequences of the Chernobyl accident in the USSR. The general objective was to assess 'the concept which the USSR has evolved to enable the population to live safely in areas affected by radioactive contamination following the Chernobyl accident, and an evaluation of the effectiveness of the steps taken in these areas to safeguard the health of the population'. Specifically, this work aimed at evaluating protective measures from 1990 onwards

  16. Secrets of safe laparoscopic surgery: Anaesthetic and surgical considerations

    Directory of Open Access Journals (Sweden)

    Srivastava Arati

    2010-01-01

    Full Text Available In recent years, laparoscopic surgery has gained popularity in clinical practice. The key element in laparoscopic surgery is creation of pneumoperitoneum and carbon dioxide is commonly used for insufflation. This pneumoperitoneum perils the normal cardiopulmonary system to a considerable extent. Every laparoscopic surgeon should understand the consequences of pneumoperitoneum; so that its untoward effects can be averted. Pneumoperitoneum increases pressure on diaphragm, leading to its cephalic displacement and thereby decreasing venous return, which can be aggravated by the position of patient during surgery. There is no absolute contraindication of laparoscopic surgery, though we can anticipate some problems in conditions like obesity, pregnancy and previous abdominal surgery. This review discusses some aspects of the pathophysiology of carbon dioxide induced pneumoperitoneum, its consequences as well as strategies to counteract them. Also, we propose certain guidelines for safe laparoscopic surgery.

  17. "Safe Zone" Classrooms: The Individual Student versus the Community

    Science.gov (United States)

    Kruk, Amber

    2013-01-01

    Independence Day School is a small college preparatory school serving grades 9-12, in rural Illinois. As part of its commitment to creating a safe school for all students, it adopted a "safe zone" classrooms policy. The policy states that classrooms where conversation about homosexuality is permitted are marked with inverted pink…

  18. Evidence supporting broader access to safe legal abortion.

    Science.gov (United States)

    Faúndes, Anibal; Shah, Iqbal H

    2015-10-01

    Unsafe abortion continues to be a major cause of maternal death; it accounts for 14.5% of all maternal deaths globally and almost all of these deaths occur in countries with restrictive abortion laws. A strong body of accumulated evidence shows that the simple means to drastically reduce unsafe abortion-related maternal deaths and morbidity is to make abortion legal and institutional termination of pregnancy broadly accessible. Despite this evidence, abortion is denied even when the legal condition for abortion is met. The present article aims to contribute to a better understanding that one can be in favor of greater access to safe abortion services, while at the same time not be "in favor of abortion," by reviewing the evidence that indicates that criminalization of abortion only increases mortality and morbidity without decreasing the incidence of induced abortion, and that decriminalization rapidly reduces abortion-related mortality and does not increase abortion rates. Copyright © 2015. Published by Elsevier Ireland Ltd.

  19. The analysis of a condition of an accident rate on highways of Tajikistan

    International Nuclear Information System (INIS)

    Davlatshoev, R.A.; Tursunov, A.A.

    2005-01-01

    In this clause the results of the analysis of an accident rate on highways of Tajikistan, according to the official information State Automobile Inspection the Ministry of Internal affairs of Republic of Tajikistan, and research of safe movement of automobiles in mountain conditions are given. On the basis of the qualitative and quantitative analysis, the ways of safe movement on roads of Republic of Tajikistan are determined

  20. Interventions to Improve Safe Sleep Among Hospitalized Infants at Eight Children's Hospitals.

    Science.gov (United States)

    Kuhlmann, Stephanie; Ahlers-Schmidt, Carolyn R; Lukasiewicz, Gloria; Truong, Therese Macasiray

    2016-02-01

    Within hospital pediatric units, there is a lack of consistent application or modeling of the American Academy of Pediatrics recommendations for safe infant sleep. The purpose of this study was to improve safe sleep practices for infants in nonneonatal pediatric units with implementation of specific interventions. This multi-institutional study was conducted by using baseline observations collected for sleep location, position, and environment (collectively, "safe sleep") of infants admitted to pediatric units. Interventions consisted of: (1) staff education, including a commitment to promote safe sleep; (2) implementing site-generated safe sleep policies; (3) designating supply storage in patient rooms; and/or (4) caregiver education. Postintervention observations of safe sleep were collected. Eight hospitals participated from the Inpatient FOCUS Group of the Children's Hospital Association. Each site received institutional review board approval/exemption. Safe sleep was observed for 4.9% of 264 infants at baseline and 31.2% of 234 infants postintervention (Ppresent in 77% of cribs at baseline and 44% postintervention. However, the mean number of unsafe items observed in each sleeping environment was reduced by >50% (P=.001). Implementation of site-specific interventions seems to improve overall safe sleep in inpatient pediatric units, although continued improvement is needed. Specifically, extra items are persistently left in the sleeping environment. Moving forward, hospitals should evaluate their compliance with American Academy of Pediatrics recommendations and embrace initiatives to improve modeling of safe sleep. Copyright © 2016 by the American Academy of Pediatrics.

  1. Inherently safe reactors

    International Nuclear Information System (INIS)

    Maartensson, Anders

    1992-01-01

    A rethinking of nuclear reactor safety has created proposals for new designs based on inherent and passive safety principles. Diverging interpretations of these concepts can be found. This article reviews the key features of proposed advanced power reactors. An evaluation is made of the degree of inherent safety for four different designs: the AP-600, the PIUS, the MHTGR and the PRISM. The inherent hazards of today's most common reactor principles are used as reference for the evaluation. It is concluded that claims for the new designs being inherently, naturally or passively safe are not substantiated by experience. (author)

  2. AFSC/REFM: Groundfish SAFE Economic Report

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Groundfish SAFE Economic Report, published annually as a supplement to the Stock Assessment and Fishery Evaluation Reports for Bering Sea and Aleutian Islands...

  3. Safe clinical practice for patients hospitalised in a suicidal crisis: a study protocol for a qualitative case study.

    Science.gov (United States)

    Berg, Siv Hilde; Rørtveit, Kristine; Walby, Fredrik A; Aase, Karina

    2017-01-27

    Suicide prevention in psychiatric care is arguably complex and incompletely understood as a patient safety issue. A resilient healthcare approach provides perspectives through which to understand this complexity by understanding everyday clinical practice. By including suicidal patients and healthcare professionals as sources of knowledge, a deeper understanding of what constitutes safe clinical practice can be achieved. This planned study aims to adopt the perspective of resilient healthcare to provide a deeper understanding of safe clinical practice for suicidal patients in psychiatric inpatient care. It will describe the experienced components and conditions of safe clinical practice and the experienced practice of patient safety. The study will apply a descriptive case study approach consisting of qualitative semistructured interviews and focus groups. The data sources are hospitalised patients in a suicidal crisis and healthcare professionals in clinical practice. This study was approved by the Regional Ethics Committee (2016/34). The results will be disseminated through scientific articles, a PhD dissertation, and national and international conferences. These findings can generate knowledge to be integrated into the practice of safety for suicidal inpatients in Norway and to improve the feasibility of patient safety measures. Theoretical generalisations can be drawn regarding safe clinical practice by taking into account the experiences of patients and healthcare professionals. Thus, this study can inform the conceptual development of safe clinical practice for suicidal patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Adoption of the B2SAFE EUDAT replication service by the EPOS community

    Science.gov (United States)

    Cacciari, Claudio; Fares, Massimo; Fiameni, Giuseppe; Michelini, Alberto; Danecek, Peter; Wittenburg, Peter

    2014-05-01

    B2SAFE is the EUDAT service for moving and replicating data between sites and storage systems for different purposes. The goal of B2SAFE is to keep the data from a repository safe by replicating it across different geographical and administrative zones according to a set of well-defined policies. It is also a way to store large volumes of data permanently at those sites which are providing powerful on-demand data analysis facilities. In particular, B2SAFE operates on the domain of registered data where data objects are referable via persistent identifiers (PIDs). B2SAFE is more than just copying data because the PIDs must be carefully managed when data objects are moved or replicated. The EUDAT B2SAFE Service offers functionality to replicate datasets across different data centres in a safe and efficient way while maintaining all information required to easily find and query information about the replica locations. The information about the replica locations and other important information is stored in PID records, each managed in separate administrative domains. The B2SAFE Service is implemented as an iRODS module providing a set of iRODS rules or policies to interface with the EPIC handle API and uses the iRODS middleware to replicate datasets from a source data (or community) centre to a destination data centre. The definition of the dataset(s) to replicate is flexible and up to the communities using the B2SAFE service. While the B2SAFE is internally using the EPIC handle API, communities have the choice to use any PID system they prefer to assign PIDs to their digital objects. A reference to one or more EUDAT B2SAFE PIDs is returned by the B2SAFE service when a dataset is replicated. The presentation will introduce the problem space of B2SAFE, presents the achievements that have been made during the last year for enabling communities to make use of the B2SAFE service, demonstrates a EPOS use cases, outlines the commonalities and differences between the policies

  5. 49 CFR 230.70 - Safe condition.

    Science.gov (United States)

    2010-10-01

    ... brake valves work properly in all positions; and (5) The water has been drained from the air-brake system. (b) Brake pipe valve required. Each steam locomotive shall have a brake pipe valve attached to.... The words “Emergency Brake Valve” shall be clearly displayed near the valve. ...

  6. The Pathway to a Safe and Effective Medication Formulary for Exploration Spaceflight

    Science.gov (United States)

    Daniels, V. R.; Bayuse, T. M.; Mulcahy, R. A.; Mcguire, R. K. M.; Antonsen, E. L.

    2017-01-01

    PURPOSE: Exploration space missions pose several challenges to providing a comprehensive medication formulary designed to accommodate the size and space limitations of the spacecraft; while addressing the individual medications needs and preferences of the Crew; the negative outcome of a degrading inventory over time, the inability to resupply before expiration dates; and the need to properly forecast the best possible medication candidates to treat conditions that will occur in the future. METHODS: The Pharmacotherapeutics Discipline has partnered with the Exploration Medical Capabilities (ExMC) Element to develop and propose a research pathway that is comprehensively focused on evidence-based models and theories, as well as on new diagnostic tools and treatments or preventive measures aimed at closure of the Med02 “Pharmacy” Gap; defined in the Human Research Program’s (HRP) risk-based research strategy. The Med02 Gap promotes the challenge to identify a strategy to ensure that medications used to treat medical conditions during exploration space missions are available, safe, and effective. It is abundantly clear that pharmaceutical intervention is an essential component of risk management planning for astronaut healthcare during exploration space. However, the quandary still remains of how to assemble a formulary that is comprehensive enough to prevent or treat anticipated medical events; and is also chemically stable, safe, and robust enough to have sufficient potency to last for the duration of an exploration space mission. In cases where that is not possible, addressing this Gap requires exploration of novel drug development techniques, dosage forms, and dosage delivery platforms that enhance chemical stability as well as therapeutic effectiveness. RESULTS: The proposed research pathway outlines the steps, processes, procedures, and a research portfolio aimed at identifying a capability that will provide a safe and effective pharmacy for any specific

  7. High-Protein Diets: Are They Safe?

    Science.gov (United States)

    Healthy Lifestyle Nutrition and healthy eating Are high-protein diets safe for weight loss? Answers from Katherine ... L.D. For most healthy people, a high-protein diet generally isn't harmful, particularly when followed ...

  8. The safe transport of radioactive materials

    International Nuclear Information System (INIS)

    Messenger, W. de L.M.

    1979-02-01

    The hazards of radioactive materials in transport are surveyed. The system whereby they are safely transported between nuclear establishments in the United Kingdom and overseas is outlined. Several popular misconceptions are dealt with. (author)

  9. IR-safe and UV-safe integrands in the EFTofLSS with exact time dependence

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Matthew [Institut de Physique Théorique, Université Paris Saclay, CEA, CNRS, 91191 Gif-sur-Yvette (France); Senatore, Leonardo, E-mail: matthew.lewandowski@ipht.fr, E-mail: senatore@stanford.edu [Stanford Institute for Theoretical Physics, Stanford University, Stanford, 94306 CA (United States)

    2017-08-01

    Because large-scale structure surveys may very well be the next leading sources of cosmological information, it is important to have a precise understanding of the cosmological observables; for this reason, the Effective Field Theory of Large-Scale Structure (EFTofLSS) was developed. So far, most results in the EFTofLSS have used the so-called Einstein-de Sitter approximation, an approximation of the time dependence which is known to be accurate to better than one percent. However, in order to reach even higher accuracy, the full time dependence must be used. The computation with exact time dependence is sensitive to both infrared (IR) and ultraviolet (UV) effects in the loop integrands, and while these effects must cancel because of diffeomorphism invariance, they make numerical computation much less efficient. We provide a formulation of the one-loop, equal-time exact-time-dependence power spectrum of density perturbations which is manifestly free of these spurious IR and UV divergences at the level of the integrand. We extend our results to the total matter mode with clustering quintessence, show that IR and UV divergences cancel, and provide the associated IR- and UV-safe integrand. This also establishes that the consistency conditions are satisfied in this system. We then use our one-loop result to do an improved precision comparison of the two-loop dark-matter power spectrum with the Dark Sky N -body simulation.

  10. Sodium heat pipe module test for the SAFE-30 reactor prototype

    International Nuclear Information System (INIS)

    Reid, Robert S.; Sena, J. Tom; Martinez, Adam L.

    2001-01-01

    Reliable, long-life, low-cost heat pipes can enable safe, affordable space fission power and propulsion systems. Advanced versions of these systems can in turn allow rapid access to any point in the solar system. Twelve stainless steel-sodium heat pipe modules were built and tested at Los Alamos for use in a non-nuclear thermohydraulic simulation of the SAFE-30 reactor (Poston et al., 2000). SAFE-30 is a near-term, low-cost space fission system demonstration. The heat pipes were designed to remove thermal power from the SAFE-30 core, and transfer this power to an electrical power conversion system. These heat pipe modules were delivered to NASA Marshall Space Flight Center in August 2000 and were assembled and tested in a prototypical configuration during September and October 2000. The construction and test of one of the SAFE-30 modules is described

  11. Could martial arts fall training be safe for persons with osteoporosis?: a feasibility study

    Science.gov (United States)

    2010-01-01

    Background Osteoporosis is a well-established risk factor for fall-related hip fractures. Training fall arrest strategies, such as martial arts (MA) fall techniques, might be useful to prevent hip fractures in persons with osteoporosis, provided that the training itself is safe. This study was conducted to determine whether MA fall training would be safe for persons with osteoporosis extrapolated from the data of young adults and using stringent safety criteria. Methods Young adults performed sideways and forward MA falls from a kneeling position on both a judo mat and a mattress as well as from a standing position on a mattress. Hip impact forces and kinematic data were collected. For each condition, the highest hip impact force was compared with two safety criteria based on the femoral fracture load and the use of a hip protector. Results The highest hip impact force during the various fall conditions ranged between 1426 N and 3132 N. Sideways falls from a kneeling and standing position met the safety criteria if performed on the mattress (max 1426 N and 2012 N, respectively) but not if the falls from a kneeling position were performed on the judo mat (max 2219 N). Forward falls only met the safety criteria if performed from a kneeling position on the mattress (max 2006 N). Hence, forward falls from kneeling position on a judo mat (max 2474 N) and forward falls from standing position on the mattress (max 3132 N) did not meet both safety criteria. Conclusions Based on the data of young adults and safety criteria, the MA fall training was expected to be safe for persons with osteoporosis if appropriate safety measures are taken: during the training persons with osteoporosis should wear hip protectors that could attenuate the maximum hip impact force by at least 65%, perform the fall exercises on a thick mattress, and avoid forward fall exercises from a standing position. Hence, a modified MA fall training might be useful to reduce hip fracture risk in persons with

  12. Could martial arts fall training be safe for persons with osteoporosis?: a feasibility study

    Directory of Open Access Journals (Sweden)

    Smulders Ellen

    2010-04-01

    Full Text Available Abstract Background Osteoporosis is a well-established risk factor for fall-related hip fractures. Training fall arrest strategies, such as martial arts (MA fall techniques, might be useful to prevent hip fractures in persons with osteoporosis, provided that the training itself is safe. This study was conducted to determine whether MA fall training would be safe for persons with osteoporosis extrapolated from the data of young adults and using stringent safety criteria. Methods Young adults performed sideways and forward MA falls from a kneeling position on both a judo mat and a mattress as well as from a standing position on a mattress. Hip impact forces and kinematic data were collected. For each condition, the highest hip impact force was compared with two safety criteria based on the femoral fracture load and the use of a hip protector. Results The highest hip impact force during the various fall conditions ranged between 1426 N and 3132 N. Sideways falls from a kneeling and standing position met the safety criteria if performed on the mattress (max 1426 N and 2012 N, respectively but not if the falls from a kneeling position were performed on the judo mat (max 2219 N. Forward falls only met the safety criteria if performed from a kneeling position on the mattress (max 2006 N. Hence, forward falls from kneeling position on a judo mat (max 2474 N and forward falls from standing position on the mattress (max 3132 N did not meet both safety criteria. Conclusions Based on the data of young adults and safety criteria, the MA fall training was expected to be safe for persons with osteoporosis if appropriate safety measures are taken: during the training persons with osteoporosis should wear hip protectors that could attenuate the maximum hip impact force by at least 65%, perform the fall exercises on a thick mattress, and avoid forward fall exercises from a standing position. Hence, a modified MA fall training might be useful to reduce hip

  13. Working safely with ionising radiation

    International Nuclear Information System (INIS)

    McDowell, D.J.

    1990-01-01

    A small leaflet provides information on working safely with ionizing radiation. Topics covered include the types of radiation, radiological units, external radiation, contamination and internal radiation, methods of protection form radiation, radiation monitors, protective clothing for contamination, personal dosemeters, radiation dose limits for classified workers and finally the Ionising Radiations Regulations 1985. (UK)

  14. [The Necessity and the Current Status of Safe Handling of Anticancer Drugs].

    Science.gov (United States)

    Kanda, Kiyoko

    2017-07-01

    Number of people who handle anticancer drugs in their profession is increasing. Anticancer drugs, which are hazardous drugs(HD), exert cytocidal effects on cancer cells, but many have also been shown to have mutagenicity, teratogenicity and carcinogenicity; therefore, safe handling of anticancer drugs is necessary. In July 2015, the first Japanese guidelines for exposure control measures, namely, the "Joint Guidelines for Safe Handling of Cancer Chemotherapy Drugs", were published jointly by 3 societies. Our guideline is the creation of the Japanese Society of Cancer Nursing(JSCN), Japanese Society of Medical Oncology(JSMO)and Japanese Society of Pharmaceutical Oncology(JASPO)and has a historical significance. This paper states the necessity of safe handling of anticancer drugs, Japan's recent movement of safe handling, the introduction of joint guidelines of safe handling of anticancer drugs, and new movement of safe handling of USP chapter 800 in the United States.

  15. Providing safe drinking water to 1.2 billion unserved people

    Energy Technology Data Exchange (ETDEWEB)

    Gadgil, Ashok J.; Derby, Elisabeth A.

    2003-06-01

    Despite substantial advances in the past 100 years in public health, technology and medicine, 20% of the world population, mostly comprised of the poor population segments in developing countries (DCs), still does not have access to safe drinking water. To reach the United Nations (UN) Millennium Goal of halving the number of people without access to safe water by 2015, the global community will need to provide an additional one billion urban residents and 600 million rural residents with safe water within the next twelve years. This paper examines current water treatment measures and implementation methods for delivery of safe drinking water, and offers suggestions for making progress towards the goal of providing a timely and equitable solution for safe water provision. For water treatment, based on the serious limitations of boiling water and chlorination, we suggest an approach based on filtration coupled with ultraviolet (UV) disinfection, combined with public education. Additionally, owing to the capacity limitations for non-governmental organizations (NGOs) to take on this task primarily on their own, we suggest a strategy based on financially sustainable models that include the private sector as well as NGOs.

  16. 10 CFR 218.12 - Pricing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Pricing. 218.12 Section 218.12 Energy DEPARTMENT OF ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.12 Pricing. The price for oil subject to a supply order issued pursuant to this subpart shall be based on the price conditions...

  17. Safe delivery, Service utilization, Metekel Zone

    African Journals Online (AJOL)

    decision making power of subjects were found to have a statistically significant association with preference of safe delivery ... Studies that focused on maternal mortality and proportion of ...... Anna M, Hannekee M, Frank Odhiambo et.al. Use.

  18. Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

    Science.gov (United States)

    Trawny, Nikolas; Huertas, Andres; Luna, Michael E.; Villalpando, Carlos Y.; Martin, Keith E.; Carson, John M.; Johnson, Andrew E.; Restrepo, Carolina; Roback, Vincent E.

    2015-01-01

    The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

  19. Portable Exhauster Position Paper

    International Nuclear Information System (INIS)

    KRISKOVICH, J.R.

    1999-01-01

    This document identifies the tasks that are involved in preparing the ''standby'' portable exhauster to support Interim Stabilization's schedule for saltwell pumping. A standby portable exhaust system will be assigned to any facility scheduled to be saltwell pumped with the exception of 241-S farm, 241-SX farm or 241-T farm. The standby portable exhauster shall be prepared for use and placed in storage. The standby portable exhaust system shall be removed from storage and installed to ventilate tanks being pumped that reach 25% LFL. There are three tasks that are evaluated in this document. Each task shall be completed to support portable exhaust system installation and operation. They are: Pre Installation Task; Portable Exhaust System Storage Task; and Portable Exhaust System Installation and Operation Task

  20. Wind pressure testing of tornado safe room components made from wood

    Science.gov (United States)

    Robert Falk; Deepak Shrestha

    2016-01-01

    To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...

  1. On the safeness of examinees and the reliability of system

    International Nuclear Information System (INIS)

    Kudo, Kazumi; Kanda, Kosuke; Saito, Kazuhiko; Maesawa, Tsuneharu; Idekami, Tomio

    1979-01-01

    The control technique of the reliability of examination system was investigated from the viewpoint of patient safety and image information, based on the prevention of microshock owing to circulatory organ checking system. As for the equipments in hospitals, the size of rooms, air conditioning system, power source installation, earth and piping arrangements should be fully discussed at the planning stage. EPR system must be introduced for the prevention for microshock. Intensive education and training are required for operators to secure safeness in operation. Thorough care should be taken to prevent bacilli infection. Further examinations were made on the control technique of the reliability of photographing system from viewpoint of image information, and it is necessary to study the factors for obtaining the reliability of compound machinery components and the devices of generating radiation. (Kobatake, H.)

  2. Fail-safe reactivity compensation method for a nuclear reactor

    Science.gov (United States)

    Nygaard, Erik T.; Angelo, Peter L.; Aase, Scott B.

    2018-01-23

    The present invention relates generally to the field of compensation methods for nuclear reactors and, in particular to a method for fail-safe reactivity compensation in solution-type nuclear reactors. In one embodiment, the fail-safe reactivity compensation method of the present invention augments other control methods for a nuclear reactor. In still another embodiment, the fail-safe reactivity compensation method of the present invention permits one to control a nuclear reaction in a nuclear reactor through a method that does not rely on moving components into or out of a reactor core, nor does the method of the present invention rely on the constant repositioning of control rods within a nuclear reactor in order to maintain a critical state.

  3. (m, M) Machining system with two unreliable servers, mixed spares and common-cause failure

    OpenAIRE

    Jain, Madhu; Mittal, Ragini; Kumari, Rekha

    2015-01-01

    This paper deals with multi-component machine repair model having provision of warm standby units and repair facility consisting of two heterogeneous servers (primary and secondary) to provide repair to the failed units. The failure of operating and standby units may occur individually or due to some common cause. The primary server may fail partially following full failure whereas secondary server faces complete failure only. The life times of servers and operating/standby units and their re...

  4. Inherently safe in situ uranium recovery

    International Nuclear Information System (INIS)

    Krumhansl, James Lee; Beauheim, Richard Louis; Brady, Patrick Vane; Arnold, Bill Walter; Kanney, Joseph F.; McKenna, Sean Andrew

    2009-01-01

    Expansion of uranium mining in the United States is a concern to some environmental groups and sovereign Native American Nations. An approach which may alleviate some problems is to develop inherently safe in situ uranium recovery ('ISR') technologies. Current ISR technology relies on chemical extraction of trace levels of uranium from aquifers that, once mined, can still contain dissolved uranium and other trace metals that are a health concern. Existing ISR operations are few in number; however, high uranium prices are driving the industry to consider expanding operations nation-wide. Environmental concerns and enforcement of the new 30 ppb uranium drinking water standard may make opening new mining operations more difficult and costly. Here we propose a technological fix: the development of inherently safe in situ recovery (ISISR) methods. The four central features of an ISISR approach are: (1) New 'green' leachants that break down predictably in the subsurface, leaving uranium, and associated trace metals, in an immobile form; (2) Post-leachant uranium/metals-immobilizing washes that provide a backup decontamination process; (3) An optimized well-field design that increases uranium recovery efficiency and minimizes excursions of contaminated water; and (4) A combined hydrologic/geochemical protocol for designing low-cost post-extraction long-term monitoring. ISISR would bring larger amounts of uranium to the surface, leave fewer toxic metals in the aquifer, and cost less to monitor safely - thus providing a 'win-win-win' solution to all stakeholders.

  5. Safe injection practice among health-care workers in Gharbiya Governorate, Egypt.

    Science.gov (United States)

    Ismail, N A; Aboul Ftouh, A M; El-Shoubary, W H; Mahaba, H

    2007-01-01

    We assessed safe injection practices among 1100 health-care workers in 25 health-care facilities in Gharbiya Governorate. Questionnaires were used to collect information and 278 injections were observed using a standardized checklist. There was a lack of infection control policies in all the facilities and a lack of many supplies needed for safe injection. Proper needle manipulation before disposal was observed in only 41% of injections, safe needle disposal in 47.5% and safe syringe disposal in 0%. Reuse of used syringes and needles was reported by 13.2% of the health-care workers and 66.2% had experienced a needle-stick injury. Only 11.3% had received a full course of hepatitis B vaccination.

  6. Safe disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Hooker, P.; Metcalfe, R.; Milodowski, T.; Holliday, D.

    1997-01-01

    A high degree of international cooperation has characterized the two studies reported here which aim to address whether radioactive waste can be disposed of safely. Using hydrogeochemical and mineralogical surveying techniques earth scientists from the British Geological Survey have sought to identify and characterise suitable disposal sites. Aspects of the studies are explored emphasising their cooperative nature. (UK)

  7. Graft-to-recipient weight ratio lower to 0.7% is safe without portal pressure modulation in right-lobe living donor liver transplantation with favorable conditions.

    Science.gov (United States)

    Lee, Seung Duk; Kim, Seong Hoon; Kim, Young-Kyu; Lee, Soon-Ae; Park, Sang-Jae

    2014-02-01

    The low graft-to-recipient weight ratio (GRWR) in adult-to-adult living donor liver transplantation (LDLT) is one of the major risk factors affecting graft survival. The goal of this study was to evaluate whether the lower limit of the GRWR can be safely reduced without portal pressure modulation in right-lobe LDLT. From 2005 to 2011, 317 consecutive patients from a single institute underwent LDLT with right-lobe grafts without portal pressure modulation. Of these, 23 had a GRWR of less than 0.7% (group A), 27 had a GRWR of ≥0.7%, recipient, donor, operation factors, laboratory findings and complications were reviewed retrospectively. The baseline demographics showed low model for end-stage liver disease score (mean 16.3+/-8.9) and high percentage of hepatocellular carcinoma (231 patients, 72.9%). Three groups by GRWR demonstrated similar characteristics except recipient body mass index and donor gender. For small-for-size syndrome, there were 3 (13.0%) in group A, 1 (3.7%) in group B, and 2 patients (0.7%) in group C (Pneed to modulate portal pressure in adult-to-adult LDLT using the right-lobe in favorable conditions including low model for end-stage liver disease score.

  8. Staying Safe on Social Network Sites

    Science.gov (United States)

    ... Tips Security Tip (ST06-003) Staying Safe on Social Networking Sites Original release date: January 26, 2011 | Last revised: ... so you should take certain precautions. What are social networking sites? Social networking sites, sometimes referred to as "friend- ...

  9. Spermicidal Activity of the Safe Natural Antimicrobial Peptide Subtilosin

    Directory of Open Access Journals (Sweden)

    Michael L. Chikindas

    2008-10-01

    Full Text Available Bacterial vaginosis (BV, a condition affecting millions of women each year, is primarily caused by the gram-variable organism Gardnerella vaginalis. A number of organisms associated with BV cases have been reported to develop multidrug resistance, leading to the need for alternative therapies. Previously, we reported the antimicrobial peptide subtilosin has proven antimicrobial activity against G. vaginalis, but not against the tested healthy vaginal microbiota of lactobacilli. After conducting tissue sensitivity assays using an ectocervical tissue model, we determined that human cells remained viable after prolonged exposures to partially-purified subtilosin, indicating the compound is safe for human use. Subtilosin was shown to eliminate the motility and forward progression of human spermatozoa in a dose-dependent manner, and can therefore be considered a general spermicidal agent. These results suggest subtilosin would be a valuable component in topical personal care products aimed at contraception and BV prophylaxis and treatment.

  10. Vitamins, Are They Safe?

    Directory of Open Access Journals (Sweden)

    Hadi Hamishehkar

    2016-12-01

    Full Text Available The consumption of a daily multivitamin among people all over the world is dramatically increasing in recent years. Most of the people believe that if vitamins are not effective, at least they are safe. However, the long term health consequences of vitamins consumption are unknown. This study aimed to assess the side effects and possible harmful and detrimental properties of vitamins and to discuss whether vitamins can be used as safe health products or dietary supplements. We performed a MEDLINE/PubMed, EMBASE, Scopus and Google Scholar search and assessed reference lists of the included studies which were published from 1993 through 2015. The studies, with an emphasis on RCTs (randomized controlled clinical trials, were reviewed. As some vitamins such as fat-soluble vitamins (vitamin A, vitamin D, vitamin E, and also some of the water-soluble vitamins like folic acid may cause adverse events and some like vitamin C is widely taken assuming that it has so many benefits and no harm, we included relevant studies with negative or undesired results regarding the effect of these vitamins on health. Our recommendation is that taking high-dose supplements of vitamins A, E, D, C, and folic acid is not always effective for prevention of disease, and it can even be harmful to the health.

  11. Safe Sleep for Babies PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the January 2018 CDC Vital Signs report. Every year, there are about 3,500 sleep-related deaths among U.S. babies. Learn how to create a safe sleep environment for babies.

  12. Contraindications to Athletic Participation. Cardiac, Respiratory, and Central Nervous System Conditions.

    Science.gov (United States)

    Moeller, James L.

    1996-01-01

    Discusses contraindications to athletic participation, examining the cardiac, respiratory, and central nervous system conditions that warrant activity disqualification. Provides guidelines about when it is safe for individuals to participate, and discusses the physician's responsibility. (SM)

  13. Fail-safe logic elements for use with reactor safety systems

    International Nuclear Information System (INIS)

    Bobis, J.P.; McDowell, W.P.

    1976-01-01

    A complete fail-safe trip circuit is described which utilizes fail-safe logic elements. The logic elements used are analog multipliers and active bandpass filter networks. These elements perform Boolean operations on a set of AC signals from the output of a reactor safety-channel trip comparator

  14. Safe injections and waste management at a Sub-Saharan regional ...

    African Journals Online (AJOL)

    Objective: To assess the knowledge and practice of safe injections and health care waste management among healthcare workers at a regional hospital in Northern Tanzania. Design: A cross sectional descriptive study with additional observations was conducted to assess the knowledge and practice of safe injections and ...

  15. Evaluation of the CDC safe water-storage intervention to improve ...

    African Journals Online (AJOL)

    Evaluation of the CDC safe water-storage intervention to improve the microbiological quality of point-of-use drinking water in rural communities in South Africa. ... use of safe household water-storage devices and water treatment processes and improvement of hygiene and sanitation practices in these rural households.

  16. The safe use of radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    As a means of promoting safety in the use of radiation sources, as well as encouraging consistency in regulatory control, the IAEA has from time to time organized training courses with the co-operation of Member State governments and organizations, to inform individuals from developing countries with appropriate responsibilities on the provisions for the safe use and regulation of radiation sources. Three such courses on the safe use of radiation sources have been held in both the USA, with the co-operation of the United States Government, and in Dublin, Ireland, with the co-operation of the Irish Government. The Training Course on the Safe Use and Regulation of Radiation Sources has been successfully given to over 77 participants from over 30 countries during the last years. The course is aimed at providing a basis of radiation protection knowledge in all aspects of the uses of radiation and of radiation sources that are used today. It is the intention of this course to provide a systematic enhancement of radioisotope safety in countries with developing radiological programmes through a core group of national authorities. The IAEA's training programmes provide an excellent opportunity for direct contact with lecturers that have extensive experience in resolving issues faced by developing countries and in providing guidance documents useful in addressing their problems. This document uses this collective experience and provides valuable technical information regarding the safety aspects of the uses not only of sealed and unsealed sources of radiation, but also for those machines that produce ionizing radiation. The first of these training courses, 'Safety and Regulation of Unsealed Sources' was held in Dublin, Ireland, June through July 1989 with the co-operation of the Nuclear Energy Board and Trinity College. This was an interregional training course, the participants came from all over the world. The second and third interregional courses, 'Safety and Regulation

  17. The safe use of radiation sources

    International Nuclear Information System (INIS)

    1995-01-01

    As a means of promoting safety in the use of radiation sources, as well as encouraging consistency in regulatory control, the IAEA has from time to time organized training courses with the co-operation of Member State governments and organizations, to inform individuals from developing countries with appropriate responsibilities on the provisions for the safe use and regulation of radiation sources. Three such courses on the safe use of radiation sources have been held in both the USA, with the co-operation of the United States Government, and in Dublin, Ireland, with the co-operation of the Irish Government. The Training Course on the Safe Use and Regulation of Radiation Sources has been successfully given to over 77 participants from over 30 countries during the last years. The course is aimed at providing a basis of radiation protection knowledge in all aspects of the uses of radiation and of radiation sources that are used today. It is the intention of this course to provide a systematic enhancement of radioisotope safety in countries with developing radiological programmes through a core group of national authorities. The IAEA's training programmes provide an excellent opportunity for direct contact with lecturers that have extensive experience in resolving issues faced by developing countries and in providing guidance documents useful in addressing their problems. This document uses this collective experience and provides valuable technical information regarding the safety aspects of the uses not only of sealed and unsealed sources of radiation, but also for those machines that produce ionizing radiation. The first of these training courses, 'Safety and Regulation of Unsealed Sources' was held in Dublin, Ireland, June through July 1989 with the co-operation of the Nuclear Energy Board and Trinity College. This was an interregional training course, the participants came from all over the world. The second and third interregional courses, 'Safety and Regulation

  18. Safe semi-supervised learning based on weighted likelihood.

    Science.gov (United States)

    Kawakita, Masanori; Takeuchi, Jun'ichi

    2014-05-01

    We are interested in developing a safe semi-supervised learning that works in any situation. Semi-supervised learning postulates that n(') unlabeled data are available in addition to n labeled data. However, almost all of the previous semi-supervised methods require additional assumptions (not only unlabeled data) to make improvements on supervised learning. If such assumptions are not met, then the methods possibly perform worse than supervised learning. Sokolovska, Cappé, and Yvon (2008) proposed a semi-supervised method based on a weighted likelihood approach. They proved that this method asymptotically never performs worse than supervised learning (i.e., it is safe) without any assumption. Their method is attractive because it is easy to implement and is potentially general. Moreover, it is deeply related to a certain statistical paradox. However, the method of Sokolovska et al. (2008) assumes a very limited situation, i.e., classification, discrete covariates, n(')→∞ and a maximum likelihood estimator. In this paper, we extend their method by modifying the weight. We prove that our proposal is safe in a significantly wide range of situations as long as n≤n('). Further, we give a geometrical interpretation of the proof of safety through the relationship with the above-mentioned statistical paradox. Finally, we show that the above proposal is asymptotically safe even when n(')

  19. Safe physical human robot interaction- past, present and future

    International Nuclear Information System (INIS)

    Pervez, Aslam; Ryu, Jeha

    2008-01-01

    When a robot physically interacts with a human user, the requirements should be drastically changed. The most important requirement is the safety of the human user in the sense that robot should not harm the human in any situation. During the last few years, research has been focused on various aspects of safe physical human robot interaction. This paper provides a review of the work on safe physical interaction of robotic systems sharing their workspace with human users (especially elderly people). Three distinct areas of research are identified: interaction safety assessment, interaction safety through design, and interaction safety through planning and control. The paper then highlights the current challenges and available technologies and points out future research directions for realization of a safe and dependable robotic system for human users

  20. Evaluation of Required Water Sources during Extended Loss of All AC Power for CANDU NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo Jae; Lee, Kyung Jin; Kim, Min Ki; Kim, Keon Yeop; Park, Da Hee; Oh, Seo Bin [FNC Technology Co., Yongin (Korea, Republic of); Chang, Young Jin; Byun, Choong Seop [KHNP, Daejeon (Korea, Republic of)

    2016-10-15

    Fukushima accident was caused by lasting long hours of Station Black-Out (SBO) triggered from natural disaster. This accident had resulted in the reactor core damage. The purpose of this study is to evaluate the required water sources to maintain hot standby conditions until 72 hours during ELAP situation. The analysis was performed with CATHENA code. CATHENA code has been developed for the best-estimated transient simulation of CANDU plants. This study was carried out to evaluate the strategy to maintain hot standby conditions during ELAP situation in CANDU reactors. In this analysis, water was supplied to SG by MSSV open and by the gravity feed. It can cool the core without damage until the dousing tank depletion. Before dousing tank depletion, the emergency water supply pump was available by emergency power restoration. The pump continuously fed water to SG. So it is expected that the reactor core can be cooled down without damage for 72 hours if water source is enough to feed. This result is useful to make a strategy against SBO including ELAP situation.

  1. SAFE-PLANE, Stress Analysis of Planar Structure by Finite Elements Method

    International Nuclear Information System (INIS)

    Cornell, D.C.; Reich, Morris

    1967-01-01

    1 - Description of problem or function: SAFE-PLANE is applied to two- dimensional structures of arbitrary geometry under in-plane loads. Either plane stress or plane strain conditions may be imposed. Mechanical and thermal loads are permitted. 2 - Method of solution: The finite-element method is used to construct a mathematical model by assembling discrete elements. The total potential energy of the structure is determined and subsequently minimized by iteration on components of the displacement field until static equilibrium of the structure is attained. Strains and stresses are computed from the resulting displacements. 3 - Restrictions on the complexity of the problem: Multi-material structures with varying rigidities converge very slowly. Not valid for incompressible materials. Maximum number of nodal points = 675. Maximum number of elements = 1350

  2. Well Connected, a platform for safe online communication and therapy

    NARCIS (Netherlands)

    Postel, Marloes Gerda; van Regteren, B.J.

    2012-01-01

    Well Connected, a platform for safe online communication and therapy Introduction Well Connected is a flexible, safe and user friendly e-health platform with a wide range of applications. Over the last 7 years 5000 patients were treated or a variety of addiction related problems. Besides creating an

  3. Safe transport of radioactive material

    International Nuclear Information System (INIS)

    1994-01-01

    Delivering radioactive material to where it is needed is a vital service to industry and medicine. Millions of packages are shipped all over the world by all modes of transport. The shipments pass through public places and must meet stringent safety requirements. This video explains how radioactive material is safely transported and describes the rules that carriers and handlers must follow

  4. 78 FR 57319 - Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines...

    Science.gov (United States)

    2013-09-18

    ...-AB20 Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; kidSAFE... proposed self-regulatory guidelines submitted by the kidSAFE Seal Program (``kidSAFE''), owned and operated... enabling industry groups or others to submit to the Commission for approval self-regulatory guidelines that...

  5. A safe workplace

    International Nuclear Information System (INIS)

    Rittsel, Hans; Andersson, Bengt A.

    1993-01-01

    Full text: The video 'A safe workplace' has been produced by ABB Atom in order to create a tool for showing different target audiences that ABB Atom Nuclear Fuel Production Plant is a safe workplace and to 'de-mystify' nuclear fuel production. The main target audiences are visitor groups and employees of the company, but the video also qualifies for use as an information tool for other target groups who ask for a proper explanation of the way nuclear fuel is produced. The summarized content of the video is as follows: All individual steps of the production process are described with focus on the safety, quality and environmental requirements. The first part shows the delivery of UF 6 (uranium hexafluoride) to the plant and the following process for the conversion to UO 2 (uranium dioxide). The conversion method used is wet conversion that includes evaporation, precipitation, filtration, washing, reduction and stabilization. The next part is a description of the fuel pellet manufacture including uranium oxide blending, pellet pressing, sintering, grinding and a final visual inspection. A separate part, describing the manufacture of fuel pellets with a burnable neutron absorber, is included. The third part shows how to produce fuel rods and complete assemblies. Some of the moments of quality supervision that support the entire manufacturing process are also shown. The last part of the video comprises a brief description of the manufacture of fuel channels and other reactor core components like control rods. The video is produced with a Swedish spoken narrative. The playing time is 15 minutes. The video will be delivered with a text printed in English and copies reproduced in the PAL/VHS system may be ordered from ABB Atom Communication Dept. telefax no +4621-11 41 90, at the price of USD 100.- or SEK 750.- each. (author)

  6. Design of a safe cylindrical lithium/thionyl chloride cell

    Science.gov (United States)

    Johnson, D. H.; Ayers, A. D.; Zupancic, R. L.; Alberto, V. S.; Bailey, J. C.

    1984-05-01

    Cell design criteria have been established which can result in a safe lithium/thionyl chloride cell. A cell vent, a low area internal anode design, cell balance and composition of the cathode-electrolyte solution have been found to be important factors in the design of a safe cell. In addition to routine testing, both undischarged and discharged cells have been subjected to electrical abuse, environmental abuse and mechanical abuse without disassembly.

  7. Effect analysis of core barrel openings under CEFR normal condition

    International Nuclear Information System (INIS)

    Zhang Yabo; Yang Hongyi

    2008-01-01

    Openings on the bottom of core barrel are important part of the decay heat removal system of China Experimental Fast Reactor (CEFR), which are designed to discharge the decay heat from reactor under accident condition. This paper analyses the effect of the openings design on the normal operation condition using the famouse CFD code CFX. The result indicates that the decay heat can be discharged safely and at the same time the effect of core barrel openings on the normal operation condition is acceptable. (authors)

  8. Preference for safe over risky options in binge eating

    Directory of Open Access Journals (Sweden)

    Rémi eNeveu

    2016-03-01

    Full Text Available Background: Binge eating has been usually viewed as a preference for risky over safe appetitive rewards although this view has been drawn without manipulating stressing-inducing food cues. In healthy women, stressful cues bias behavior for safer options, raising the question of whether food cues modulate binging patients’ behaviors towards safer options.Method: A cross-sectional study was conducted with binging patients (20 bulimia nervosa (BN and 23 binging anorexia nervosa (ANB patients and two control groups (22 non-binging restrictive (ANR anorexia nervosa patients and 20 healthy participants, without any concomitant impulsive disorder. We assessed decisions under risk with a gambling task with known probabilities and decisions under uncertainty with the balloon analog risk taking task (BART with unknown probabilities of winning, in three cued-conditions including neutral, binge food and stressful cues.Results: In the gambling task, binging patients and ANR patients adopted similar safer attitudes and coherently elicited a higher aversion to losses when primed by food as compared to neutral cues. This differential behavior was also observed in the BART in BN and ANR patients only, aligning with the behavior of healthy controls when primed with stressful cues. In ANB patients, similar safer behaviors were observed in food and neutral conditions in the BART but with a higher variability in their choices in food condition. This higher variability was associated with higher difficulties to discard irrelevant information. Conclusion: Decision making under risk and under uncertainty is not fundamentally altered in binging patients but might be disturbed by a concomitant task.

  9. Stay Safe and Healthy This Winter!

    Centers for Disease Control (CDC) Podcasts

    2010-11-23

    In this podcast for kids, the Kidtastics offer some simple ways to stay safe and healthy during the winter holiday season.  Created: 11/23/2010 by CDC Office of Women’s Health.   Date Released: 11/23/2010.

  10. Implicit attitudes towards risky and safe driving in a Danish sample

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne

    ; further, self-reports of the intention to drive safely (or not) are socially sensitive. Therefore, we examined automatic preferences towards safe and risky driving with a Go/No-go Association Task (GNAT). The results suggest that (1) implicit attitudes towards driving behavior can be measured reliably...... with the GNAT; (2) implicit attitudes towards safe driving versus towards risky driving may be separable constructs. We propose that research on driving behavior may benefit from routinely including measures of implicit cognition. A practical advantage is a lesser susceptibility to social desirability biases......, compared to self-report methods. Pending replication in future research, the apparent dissociation between implicit attitudes towards safe versus risky driving that we observed may contribute to a greater theoretical understanding of the causes of unsafe and risky driving behavior....

  11. Effects of irritant chemicals on Aedes aegypti resting behavior: is there a simple shift to untreated "safe sites"?

    Directory of Open Access Journals (Sweden)

    Hortance Manda

    2011-07-01

    Full Text Available BACKGROUND: Previous studies have identified the behavioral responses of Aedes aegypti to irritant and repellent chemicals that can be exploited to reduce man-vector contact. Maximum efficacy of interventions based on irritant chemical actions will, however, require full knowledge of variables that influence vector resting behavior and how untreated "safe sites" contribute to overall impact. METHODS: Using a laboratory box assay, resting patterns of two population strains of female Ae. aegypti (THAI and PERU were evaluated against two material types (cotton and polyester at various dark:light surface area coverage (SAC ratio and contrast configuration (horizontal and vertical under chemical-free and treated conditions. Chemicals evaluated were alphacypermethrin and DDT at varying concentrations. RESULTS: Under chemical-free conditions, dark material had significantly higher resting counts compared to light material at all SAC, and significantly increased when material was in horizontal configuration. Cotton elicited stronger response than polyester. Within the treatment assays, significantly higher resting counts were observed on chemical-treated dark material compared to untreated light fabric. However, compared to matched controls, significantly less resting observations were made on chemical-treated dark material overall. Most importantly, resting observations on untreated light material (or "safe sites" in the treatment assay did not significantly increase for many of the tests, even at 25% SAC. Knockdown rates were ≤5% for all assays. Significantly more observations of flying mosquitoes were made in test assays under chemical-treatment conditions as compared to controls. CONCLUSIONS/SIGNIFICANCE: When preferred Ae. aegypti resting sites are treated with chemicals, even at reduced treatment coverage area, mosquitoes do not simply move to safe sites (untreated areas following contact with the treated material. Instead, they become agitated

  12. Safe and effective use of medicines for ethnic minorities

    DEFF Research Database (Denmark)

    Dam, Pernille; El-Souri, Mira Mahmoud; Herborg, Hanne

    2015-01-01

    , there was a need to adapt a previously developed and validated medicine-based intervention “safe and effective use of medicines” to this vulnerable group of unemployed ethnic minority patients. Methods: The objective of this before-after study was to improve medicines adherence, health status and work ability...... of the target group through an individualized pharmacist delivered intervention with focus on safe and effective implementation of medical treatments. The target group was ethnic minorities of non-western origin affiliated with a job center. Results: At baseline, 35.7 % of the patients had a potential adherence...... to the intervention. Conclusion: The counseling program “Safe and effective use of medicines” was successfully adapted to unemployed ethnic minority patients, and tested in a new collaboration between job centers and community pharmacies. The counseling program resulted in statistically significant improvements...

  13. Load shedding and emergency load sequencing system at Sizewell B power station

    International Nuclear Information System (INIS)

    Bowcock, S.; Miller, D.

    1992-01-01

    Sizewell B Nuclear Power Station has a main electrical system that connects together the main turbo-generators, generating at 23.5kV, the 400kV grid and the auxiliary equipment required to operate the station. A separate essential electrical system fed from the main electrical system, supplies all the auxiliaries required to shut-down the nuclear reactor and maintain it in a safe shut-down condition. For safety reasons four similar independent essential electrical systems are provided, each headed by a 3.3kV switchboard and a stand-by 8MW diesel generator. Feeds from the 3.3kV switchboards in turn supply the essential 3.3kV drives and transformer fed 415V essential switchboards. The function of the Load Shedding and Emergency Load Sequencing (LSELS) System is to monitor the condition of the 3.3kV incoming supply from the main electrical system to each essential 3.3kV switchboard and initiate its replacement, with the supply from the associated diesel generator, if it is outside set parameters. In order to achieve this transfer the essential electrical system load must be reduced to a level which the diesel can accommodate as a standing load and then allow the sequenced reconnection of required loads so as not to overload the diesel. The LSELS equipment is categorised as Safety Category 1E and has a significant importance to the safe operation of the power station. Therefore the design of the system must be highly reliable and the purpose of this paper is to detail the design approach used to ensure that a high system reliability is achieved. (Author)

  14. BWR ATWS mitigation by Fine Motion Control Rod

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.; Mallen, A.; Diamond, D.

    1994-01-01

    Two main methods of ATWS mitigation in a SBWR are: fine Motion control Rods (FMCRD) and Boron injection via the Standby Liquid control System (SLCS). This study has demonstrated that the use of FMCRD along with feedwater runback mitigated the conditions due to reactivity insertion and possible ATWS in a BWR which is similar to SBWR

  15. Embracing Safe Ground Test Facility Operations and Maintenance

    Science.gov (United States)

    Dunn, Steven C.; Green, Donald R.

    2010-01-01

    Conducting integrated operations and maintenance in wind tunnel ground test facilities requires a balance of meeting due dates, efficient operation, responsiveness to the test customer, data quality, effective maintenance (relating to readiness and reliability), and personnel and facility safety. Safety is non-negotiable, so the balance must be an "and" with other requirements and needs. Pressure to deliver services faster at increasing levels of quality in under-maintained facilities is typical. A challenge for management is to balance the "need for speed" with safety and quality. It s especially important to communicate this balance across the organization - workers, with a desire to perform, can be tempted to cut corners on defined processes to increase speed. Having a lean staff can extend the time required for pre-test preparations, so providing a safe work environment for facility personnel and providing good stewardship for expensive National capabilities can be put at risk by one well-intending person using at-risk behavior. This paper documents a specific, though typical, operational environment and cites management and worker safety initiatives and tools used to provide a safe work environment. Results are presented and clearly show that the work environment is a relatively safe one, though still not good enough to keep from preventing injury. So, the journey to a zero injury work environment - both in measured reality and in the minds of each employee - continues. The intent of this paper is to provide a benchmark for others with operational environments and stimulate additional sharing and discussion on having and keeping a safe work environment.

  16. Elementare Bildungseinrichtungen als safe spaces für (religiöse Differenz

    Directory of Open Access Journals (Sweden)

    Helena Stockinger

    2016-12-01

    Full Text Available ENGLISH: Educational institutions sometimes do not offer a space for (religious difference. Based on this fact the term safe space is theoretically specified. It seems important to develop kindergartens as safe spaces in wich learning, belonging and recognizing are possible. As one characteristic of the culture of safe spaces the recognition of (religious difference is pointed out, especially being sensitive about and broaching the issue of difference. DEUTSCH: Bildungseinrichtungen stellen teilweise keinen Artikulationsraum für (religiöse Differenz bereit, wodurch einzelne Kinder organisational benachteiligt werden. Elementare Bildungseinrichtungen könnten aber Räume sein, in denen Lernen, Zugehörigkeit und Anerkennung möglich sind. Hierzu wird der Begriff des safe space beleuchtet und auf elementare Bildungseinrichtungen übertragen. Als ein Merkmal der Kultur der safe spaces gilt die Anerkennung der (religiösen Differenz, indem diese sensibel wahrgenommen und thematisiert wird.

  17. Safe reduction rules for weighted treewidth

    NARCIS (Netherlands)

    Eijkhof, F. van den; Bodlaender, H.L.; Koster, A.M.C.A.

    2002-01-01

    Several sets of reductions rules are known for preprocessing a graph when computing its treewidth. In this paper, we give reduction rules for a weighted variant of treewidth, motivated by the analysis of algorithms for probabilistic networks. We present two general reduction rules that are safe for

  18. The role of safe practices in hospitals’ total factor productivity

    Directory of Open Access Journals (Sweden)

    Timothy R Huerta

    2011-01-01

    Full Text Available Timothy R Huerta1, Mark A Thompson2, Eric W Ford31Center for Health Innovation, Education, and Research, 2Rawls College of Business, Texas Tech University, Lubbock, TX, USA; 3Forsyth Medical Center Distinguished Professor of Health Care, The University of North Carolina Greensboro, Greensboro, NC, USAAbstract: The dual aims of improving safety and productivity are a major part of the health care reform movement hospital leaders must manage. Studies exploring the two phenomena conjointly and over time are critical to understanding how change in one dimension influences the other over time. A Malmquist approach is used to assess hospitals’ relative productivity levels over time. Analysis of variance (ANOVA algorithms were executed to assess whether or not the Malmquist Indices (MIs correlate with the safe practices measure. The American Hospital Association’s annual survey and the Centers for Medicare and Medicaid Services’ Case Mix Index for fiscal years 2002–2006, along with Leapfrog Group’s annual survey for 2006 were used for this study. Leapfrog Group respondents have significantly higher technological change (TC and total factor productivity (TFP than nonrespondents without sacrificing technical efficiency changes. Of the three MIs, TC (P < 0.10 and TFP (P < 0.05 had significant relationships with the National Quality Forum’s Safe Practices score. The ANOVA also indicates that the mean differences of TFP measures progressed in a monotonic fashion up the Safe Practices scale. Adherence to the National Quality Forum’s Safe Practices recommendations had a major impact on hospitals’ operating processes and productivity. Specifically, there is evidence that hospitals reporting higher Safe Practices scores had above average levels of TC and TFP gains over the period assessed. Leaders should strive for increased transparency to promote both quality improvement and increased productivity.Keywords: safety, productivity, quality, safe

  19. SAFE users manual. Volume 4. Computer programs

    International Nuclear Information System (INIS)

    Grady, L.M.

    1983-06-01

    Documentation for the Safeguards Automated Facility Evaluation (SAFE) computer programs is presented. The documentation is in the form of subprogram trees, program abstracts, flowcharts, and listings. Listings are provided on microfiche

  20. Method of safely operating nuclear reactor

    International Nuclear Information System (INIS)

    Ochiai, Kanehiro.

    1976-01-01

    Purpose: To provide a method of safely operating an nuclear reactor, comprising supporting a load applied to a reactor container partly with secondary container facilities thereby reducing the load borne by the reactor container when water is injected into the core to submerge the core in an emergency. Method: In a reactor emergency, water is injected into the reactor core thereby to submerge the core. Further, water is injected into a gap between the reactor container and the secondary container facilities. By the injection of water into the gap between the reactor container and the secondary container facilities a large apparent mass is applied to the reactor container, as a result of which the reactor container undergoes the same vibration as that of the secondary container facilities. Therefore, the load borne by the reactor container itself is reduced and stress at the bottom part of the reactor container is released. This permits the reactor to be operated more safely. (Moriyama, K.)

  1. Is irradiation of food stuffs safe?

    International Nuclear Information System (INIS)

    Maheshwari, Raaz K.; Yadav, Rajesh K.

    2014-01-01

    Many advanced and several developing countries have abundant supplies of fresh, safe and nutritious food stuffs. Yet, despite the many precautions and processes in place to ensure safe food supply, microbial contamination is still a concern. There are a number of food processing tools available that provide additional protection for the food we consume. One very promising tool is food irradiation, which is a process of imparting ionizing energy to food to kill microorganisms. Food irradiation is the process of exposing food to a controlled source of ionising radiation for the purposes of reduction of microbial Ioad, destruction of pathogens, extension of product shelf life, and/or disinfection of produce. The term irradiation often evokes fears of nuclear radioactivity and cancer among consumers. The process seems frightening because it is powerful and invisible. Consequently questions and concerns exist particularly about the safety or wholesomeness of irradiated food. The paper highlights food irradiation as a food safety measure and the issues of concerns for consumers. (author)

  2. LEADIR-PS: the path to a safe and economic SMR

    Energy Technology Data Exchange (ETDEWEB)

    Hart, R.S. [Nothern Nuclear Industries Inc., Cambridge, Ontario (Canada)

    2014-07-01

    Northern Nuclear Industries Incorporated (N{sup 2} I{sup 2}) is developing a family of Small Modular Reactors (SMRs) called LEADIR-PS, an acronym for LEAD-cooled Integral Reactor-Passively Safe. LEADIR-PS plants under development, focused on process heat applications and the energy demands of Canada, are the LEADIR-PS100 with an output of 100 MWth and LEADIR-PS300 with an output of 300 MWth. A plant consisting of six LEADIR-PS300 reactor modules serving a common turbine-generator, called the LEADIR-PS Six-Pack, is focused on serving areas with higher energy demands. LEADIR-PS integrates the inherent safety features of the Modular High Temperature Gas Reactor and molten lead coolant in an integral pool type reactor configuration. Molten lead coolant, which boils at 1750 {sup o}C,avoids the cost of a reactor pressure vessel and high pressure/high temperature reactor coolant systems, and the safety concerns regarding pressure vessel and large capacity reactor coolant system piping rupture and precludes evaporation of the coolant. Molten lead does not chemically react with air, water, or graphite. The Gen IV+ LEADIR-PS plants are inherently/passively safe. There are no active systems required for safe shutdown and decay heat removal. Safety is assured without active or stored energy power supply, without a requirement to reposition valves or other devices and operator intervention or action. The unprecedented safety achieved by LEADIR-PS reactors avoids requirements for a large exclusion radius and demanding evacuation plan requirements. LEADIR-PS, with steam conditions of 370 {sup o}C and 12 MPa (more than twice that of water cooled reactors), can serve over 85% of the world's non-transportation process heat demands and is ideally suited to serving Combined Heat and Electricity demands and industrial parks. Energy utilization of over 95% is feasible in process heat and Combined Heat and Electricity applications. The simple robust design of LEADIR-PS plants in

  3. Type-safe pattern combinators

    DEFF Research Database (Denmark)

    Rhiger, Morten

    2009-01-01

    Macros still haven't made their way into typed higher-order programming languages such as Haskell and Standard ML. Therefore, to extend the expressiveness of Haskell or Standard ML, one must express new linguistic features in terms of functions that fit within the static type systems of these lan...... of these languages. This is particularly challenging when introducing features that span across multiple types and that bind variables. We address this challenge by developing, in a step by step manner, mechanisms for encoding patterns and pattern matching in Haskell in a type-safe way....

  4. N,N-diethyl phenylacetamide (DEPA): A safe and effective repellent for personal protection against hematophagous arthropods.

    Science.gov (United States)

    Kalyanasundaram, Muthuswami; Mathew, Nisha

    2006-05-01

    Repellents play an important role in protecting humans from the bites of insect pests. An effective and safe repellent will be useful in reducing human-vector contact and thereby help in the interruption of vector borne disease transmission. Because of the unavailability of m-toluic acid in India for the manufacture of N,N-diethyl m-toluamide (DEET), there is a need to develop an alternate effective and safe insect repellent. In total, 120 substituted amides were synthesized and tested for repellency at 1.0 mg/cm2 under laboratory conditions. Among these amides, N,N-diethyl phenylacetamide (DEPA), applied at 1.0 mg/cm2 in different oil bases, was found to exhibit promising repellency (6-8 h) in the laboratory when tested against Aedes aegypti (L.) The repellent DEPA was evaluated on army personnel in comparison with dimethylphthalate (DMP) and DEET against mosquitoes, black flies, and land leeches under field condition in the North-East Frontier area of India. Both DEPA and DEET displayed broad-spectrum repellency. DEPA was more effective than DMP against all test organisms. However, no significant difference was noticed between DEPA and DEET for repellency at 0.25 and 0.5 mg/cm2 against black flies and mosquitoes. DMP was the least effective among the three compounds in the field studies. The relative potency of DEPA in comparison with DEET and DMP for repellency against Phlebotomine sand flies also was determined. At 0.1 mg/cm2, both DEPA and DEET were found to be equally effective with a protection time from 4.37 +/- 0.08 to 4.45 +/- 0.15 h. Both compounds were significantly more effective than DMP. At 0.2 mg/cm2, DEPA and DEET provided protection times of 6.52 +/- 0.08 and 7.15 +/- 0.15 h, respectively. DEPA was formulated into a vanishing cream, a pharmacologically safe polymer-based liquid, and a liposphere lotion. The vanishing cream and the two-polymer liquid formulations enhanced protection times from 4.4 to 6.5 and 7.13 h, respectively, compared with an

  5. Review of Project SAFE: Comments on biosphere conceptual model description and risk assessment methodology

    International Nuclear Information System (INIS)

    Klos, Richard; Wilmot, Roger

    2002-09-01

    The Swedish Nuclear Fuel and Waste Management Company's (SKB's) most recent assessment of the safety of the Forsmark repository for low-level and intermediate-level waste (Project SAFE) is currently undergoing review by the Swedish regulators. As part of its review, the Swedish Radiation Protection Institute (SSI) identified that two components of SAFE require more detailed review: (i) the conceptual model description of the biosphere system, and (ii) SKB's risk assessment methodology. We have reviewed the biosphere system interaction matrix and how this has been used in the identification, justification and description of biosphere models for radiological assessment purposes. The risk assessment methodology has been reviewed considering in particular issues associated with scenario selection, assessment timescale, and the probability and risk associated with the well scenario. There is an extensive range of supporting information on which biosphere modelling in Project SAFE is based. However, the link between this material and the biosphere models themselves is not clearly set out. This leads to some contradictions and mis-matches between description and implementation. One example concerns the representation of the geosphere-biosphere interface. The supporting description of lakes indicates that interaction between groundwaters entering the biosphere through lake bed sediments could lead to accumulations of radionuclides in sediments. These sediments may become agricultural areas at some time in the future. In the numerical modelling of the biosphere carried out in Project SAFE, the direct accumulation of contaminants in bed sediments is not represented. Application of a more rigorous procedure to ensure numerical models are fit for purpose is recommended, paying more attention to issues associated with the geosphere-biosphere interface. A more structured approach to risk assessment would be beneficial, with a better explanation of the difference between

  6. Traffic safety program for school children through safe action and safe condition

    Science.gov (United States)

    Yulianto, Budi; Setiono, Mahmudah, Amirotul Musthofiah Hidayah; Santoso, Anjar Budi

    2017-06-01

    The facts indicate that the rights of pedestrians is on the wane. Many motorists are unwilling to provide a space for pedestrians, even when they want to cross the road at zebra-cross facility. The data of traffic accident in Surakarta City showed that 7.0% of accident victims in 2014 to 2015 were children aged 5-15 or the group of school-aged children. In general, the location of schools is on the edge of the road where a lot of vehicles run at high speed. Hence, it is very dangerous for the school children to cross the road. Pertaining to this issue, the Department of Transportation implements a program named School Safety Zone (ZoSS). ZoSS is a time-dependent speed control zone consisting of road markings, traffic signs, optional traffic signals, and rumble strips. The objective of this study was to evaluate the effectiveness of the ZoSS based on the perception of the users, including the students, teachers, parents, and community. This study was conducted through a series of activities including the distribution of questionnaire to obtain the road users' perceptions. The results showed that most of the respondents understood the meaning, aim, and benefit of ZoSS. However, it also found that traffic sign and method of cross the road (Four-T) was not recognized appropriately by the respondents. ZoSS program was generally ineffective since the pedestrians felt unsafe to cross the road due to the high-speed vehicles.

  7. FFTF Plant transition mission analysis report

    International Nuclear Information System (INIS)

    Lund, D.P.

    1995-01-01

    FFTF (Fast Flux Test Facility) is a 400-MW(t) sodium-cooled, fast flux test reactor at Hanford, designed to test fuels and materials for advanced nuclear power plants; it has no capability for generating electric power. Since a long-term mission could not be found for FFTF, it was placed in standby, and a recommendation was made that it be shut down. Purpose of the FFTF Transition Project is to prepare it for Decontamination and Decommissioning; this will be accomplished by establishing a passively safe and environmentally secure configuration, that can be preserved for several decades. This report presents the results of the mission analysis, which is required by Hanford systems engineering procedures

  8. Using over-the-counter medicines safely

    Science.gov (United States)

    ... about OTC drugs. About OTC Medicines You can buy OTC medicines without a prescription in: Drug stores Grocery stores ... Safely You should: Examine the package before you buy it. Make sure it has not been tampered with. Never use medicine you have bought that does not look the ...

  9. Safe structural food bolus in elderly: the relevant parameters

    OpenAIRE

    Vandenberghe-Descamps, Mathilde; Septier, Chantal; Prot, Aurélie; Tournier, Carole; Hennequin, Martine; Vigneau, Evelyne; Feron, Gilles; Labouré, Hélène

    2017-01-01

    Mastication is essential to prepare food into a bolus ready to be swallowed safely, with no choking risk. Based on food bolus properties, a masticatory normative indicator was developed by Woda et al. (2010) to identify impaired masticatory function within good oral health population. The aim of the present study was to identify relevant parameters of bolus' structure to differentiate safe to unsafe bolus among elderly contrasting by their dental status.93 elderly, 58% with at least 7 posteri...

  10. Safe Exploration for Identifying Linear Systems via Robust Optimization

    OpenAIRE

    Lu, Tyler; Zinkevich, Martin; Boutilier, Craig; Roy, Binz; Schuurmans, Dale

    2017-01-01

    Safely exploring an unknown dynamical system is critical to the deployment of reinforcement learning (RL) in physical systems where failures may have catastrophic consequences. In scenarios where one knows little about the dynamics, diverse transition data covering relevant regions of state-action space is needed to apply either model-based or model-free RL. Motivated by the cooling of Google's data centers, we study how one can safely identify the parameters of a system model with a desired ...

  11. Elementare Bildungseinrichtungen als safe spaces für (religiöse) Differenz

    OpenAIRE

    Helena Stockinger

    2016-01-01

    ENGLISH: Educational institutions sometimes do not offer a space for (religious) difference. Based on this fact the term safe space is theoretically specified. It seems important to develop kindergartens as safe spaces in wich learning, belonging and recognizing are possible. As one characteristic of the culture of safe spaces the recognition of (religious) difference is pointed out, especially being sensitive about and broaching the issue of difference. DEUTSCH: Bildungseinrichtungen stellen...

  12. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  13. Safe prescribing: a titanic challenge

    Science.gov (United States)

    Routledge, Philip A

    2012-01-01

    The challenge to achieve safe prescribing merits the adjective ‘titanic’. The organisational and human errors leading to poor prescribing (e.g. underprescribing, overprescribing, misprescribing or medication errors) have parallels in the organisational and human errors that led to the loss of the Titanic 100 years ago this year. Prescribing can be adversely affected by communication failures, critical conditions, complacency, corner cutting, callowness and a lack of courage of conviction, all of which were also factors leading to the Titanic tragedy. These issues need to be addressed by a commitment to excellence, the final component of the ‘Seven C's’. Optimal prescribing is dependent upon close communication and collaborative working between highly trained health professionals, whose role is to ensure maximum clinical effectiveness, whilst also protecting their patients from avoidable harm. Since humans are prone to error, and the environments in which they work are imperfect, it is not surprising that medication errors are common, occurring more often during the prescribing stage than during dispensing or administration. A commitment to excellence in prescribing includes a continued focus on lifelong learning (including interprofessional learning) in pharmacology and therapeutics. This should be accompanied by improvements in the clinical working environment of prescribers, and the encouragement of a strong safety culture (including reporting of adverse incidents as well as suspected adverse drug reactions whenever appropriate). Finally, members of the clinical team must be prepared to challenge each other, when necessary, to ensure that prescribing combines the highest likelihood of benefit with the lowest potential for harm. PMID:22738396

  14. Think Before You Ink: Are Tattoos Safe?

    Science.gov (United States)

    ... Consumers Consumer Updates Think Before You Ink: Are Tattoos Safe? Share Tweet Linkedin Pin it More sharing ... I be concerned about unsafe practices, or the tattoo ink itself? Both. While you can get serious ...

  15. Safe Eats - Eating Out and Bringing In

    Science.gov (United States)

    ... to stay safe. What's On the Menu? When dining out: Remember that harmful bacteria can be hidden ... above the "danger zone." Remember the 2-Hour Rule : Discard any perishables (foods that can spoil or ...

  16. Hydroxylamine Nitrate Decomposition under Non-radiological Conditions

    Energy Technology Data Exchange (ETDEWEB)

    McFarlane, Joanna [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Delmau, Laetitia Helene [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); DePaoli, David W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mattus, Catherine H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Phelps, Clarice E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Roach, Benjamin D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-07-01

    Hydroxylamine nitrate (HAN) is used to reduce Pu(IV) to Pu(III) in the separation of plutonium from uranium. HAN becomes unstable under certain conditions and has been known to explode, causing injury to humans including death. Hence, it is necessary to deactivate HAN once the reduction of plutonium is finished. This report reviews what is known about the chemistry of HAN and various methods to achieve a safe decomposition. However, there are areas where more information is needed to make a decision about the handling of HAN in reprocessing of nuclear fuel. Experiments have demonstrated a number of non-radiolytic ways to safely decompose HAN, including heating in HNO3, photolytic oxidation in the presence of H2O2, and the addition of a metal such as Fe(III) that will oxidize the HAN.

  17. Safe distance car-following model including backward-looking and its stability analysis

    Science.gov (United States)

    Yang, Da; Jin, Peter Jing; Pu, Yun; Ran, Bin

    2013-03-01

    The focus of this paper is the car-following behavior including backward-looking, simply called the bi-directional looking car-following behavior. This study is motivated by the potential changes of the physical properties of traffic flow caused by the fast developing intelligent transportation system (ITS), especially the new connected vehicle technology. Existing studies on this topic focused on general motors (GM) models and optimal velocity (OV) models. The safe distance car-following model, Gipps' model, which is more widely used in practice have not drawn too much attention in the bi-directional looking context. This paper explores the property of the bi-directional looking extension of Gipps' safe distance model. The stability condition of the proposed model is derived using the linear stability theory and is verified using numerical simulations. The impacts of the driver and vehicle characteristics appeared in the proposed model on the traffic flow stability are also investigated. It is found that taking into account the backward-looking effect in car-following has three types of effect on traffic flow: stabilizing, destabilizing and producing non-physical phenomenon. This conclusion is more sophisticated than the study results based on the OV bi-directional looking car-following models. Moreover, the drivers who have the smaller reaction time or the larger additional delay and think the other vehicles have larger maximum decelerations can stabilize traffic flow.

  18. Safe pediatric surgery: development and validation of preoperative interventions checklist

    Directory of Open Access Journals (Sweden)

    Maria Paula de Oliveira Pires

    2013-09-01

    Full Text Available OBJECTIVES: this study was aimed at developing and validating a checklist of preoperative pediatric interventions related to the safety of surgical patients. METHOD: methodological study concerning the construction and validation of an instrument with safe preoperative care indicators. The checklist was subject to validation through the Delphi technique, establishing a consensus level of 80%. RESULTS: five professional specialists in the area conducted the validation and a consensus on the content and the construct was reached after two applications of the Delphi technique. CONCLUSION: the "Safe Pediatric Surgery Checklist", simulating the preoperative trajectory of children, is an instrument capable of contributing to the preparation and promotion of safe surgery, as it identifies the presence or absence of measures required to promote patient safety.

  19. Development status of PIUS/ISER - a inherently safe reactor for the international use

    International Nuclear Information System (INIS)

    Wakabayashi, Hiroaki

    1987-01-01

    It is just in early 1980s that LWR-based nuclear power has become a substantial power source. Though the safety level of nuclear power is always claimed to be sufficiently high by the industry, it rests on the idea of defense in depth, the calculation by probabilistic risk assessment (PRA) or probabilistic safety assessment (PSA). The TMI-2 and Chernobyl-4 accidents occurred in the industrially most advanced countries. In this paper, an alternative way to safe nuclear power is sought in so-called inherently safe reactors (ISR) including the LWR type PIUS/ISER. With proper consideration into the design of nuclear reactor plants, those can be made basically safe through the use of passive safe mechanism for their design. In short, an ISR is a nuclear power reactor which has passive and intrinsic core cooling capability and automatic shutdown capability. As the nuclear power reactors which are currently claimed to be inherently safe, there are the process inherent and ultimately safe reactor (PIUS) of ASEA-ATOM Sweden and the inherently safe and economical reactor (ISER) of the University of Tokyo, Japan, of LWR type. The current status of the development, the reliability, and some technical problems of ISER/PIUS and the attitude of various countries toward ISER/PIUS are described. (Kako, I.)

  20. Layered Safe Motion Planning for Autonomous Vehicles.

    Science.gov (United States)

    1995-09-01

    The major problem addressed by this research is how to plan a safe motion for autonomous vehicles in a two dimensional, rectilinear world. With given start and goal configurations, the planner performs motion planning which