WorldWideScience

Sample records for safe patient handling

  1. Ergonomics: safe patient handling and mobility.

    Science.gov (United States)

    Hallmark, Beth; Mechan, Patricia; Shores, Lynne

    2015-03-01

    This article reviews and investigates the issues surrounding ergonomics, with a specific focus on safe patient handling and mobility. The health care worker of today faces many challenges, one of which is related to the safety of patients. Safe patient handling and mobility is on the forefront of the movement to improve patient safety. This article reviews the risks associated with patient handling and mobility, and informs the reader of current evidence-based practice relevant to this area of care. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Saving our backs: safe patient handling and mobility for home care.

    Science.gov (United States)

    Beauvais, Audrey; Frost, Lenore

    2014-01-01

    Predicted work-related injuries for nurses and home healthcare workers are on the rise given the many risk factors in the home environment and the escalating demands for home healthcare workers in the United States. Fortunately, safe patient handling and mobility programs can dramatically decrease injuries. Despite strides being made to promote safe patient handling and mobility programs in acute care, more can be done to establish such initiatives in the home care setting.

  3. Comparison of Two Educational Methods on Nurses' Adoption of Safe Patient Handling Techniques

    Science.gov (United States)

    Folami, Florence

    2010-01-01

    Musculoskeletal injuries caused by patient lifting and transfers are a concern to health care workers. The Safe Patient Handling Act calls for all health care organizations to move to mechanical assistance from previous manual methods of transfers. This research analyzed two different educational programs that addressed safe patient handling for…

  4. Principles for the Safe Moving and Handling of Patients

    Directory of Open Access Journals (Sweden)

    Wanless Stephen

    2016-12-01

    Full Text Available Human movement when walking or running is a widely researched area. However, there is an increased incidence of musculoskeletal injury from poor positioning when moving and handling patients amongst healthcare professionals and is one of the main causes of long term musculoskeletal health problems. In the clinical area, an individual’s musculoskeletal health system is subjected to mechanical loading, increasing the body’s stress and strain limits, and once these are exceeded injury occurs. The risk of pain and injury has a direct relation from the over use of poor posture from poor moving and handling, which in turn can cause loss of strength and reduce musculoskeletal function. This can be changed through healthcare workers adopting safe biomechanical body movements during patient handling tasks.

  5. Safe Patient Handling and Mobility: Development and Implementation of a Large-Scale Education Program.

    Science.gov (United States)

    Lee, Corinne; Knight, Suzanne W; Smith, Sharon L; Nagle, Dorothy J; DeVries, Lori

    This article addresses the development, implementation, and evaluation of an education program for safe patient handling and mobility at a large academic medical center. The ultimate goal of the program was to increase safety during patient mobility/transfer and reduce nursing staff injury from lifting/pulling. This comprehensive program was designed on the basis of the principles of prework, application, and support at the point of care. A combination of online learning, demonstration, skill evaluation, and coaching at the point of care was used to achieve the goal. Specific roles and responsibilities were developed to facilitate implementation. It took 17 master trainers, 88 certified trainers, 176 unit-based trainers, and 98 coaches to put 3706 nurses and nursing assistants through the program. Evaluations indicated both an increase in knowledge about safe patient handling and an increased ability to safely mobilize patients. The challenge now is sustainability of safe patient-handling practices and the growth and development of trainers and coaches.

  6. Texas passes first law for safe patient handling in America: landmark legislation protects health-care workers and patients from injury related to manual patient lifting.

    Science.gov (United States)

    Hudson, Mary Anne

    2005-01-01

    On June 17,2005, Texas Governor Rick Perry (R) signed into law Senate Bill 1525, making Texas the first state in the nation to require hospitals and nursing homes to implement safe patient handling and movement programs. Governor Perry is to be commended for this heroic first stand for safe patient handling in America. The landmark legislation will take effect January 1, 2006, requiring the establishment of policy to identify, assess, and develop methods of controlling the risk of injury to patients and nurses associated with lifting, transferring, repositioning, and movement of patients; evaluation of alternative methods from manual lifting to reduce the risk of injury from patient lifting, including equipment and patient care environment; restricting, to the extent feasible with existing equipment, manual handling of all or most of a patient's weight to emergency, life-threatening, or exceptional circumstances; and provision for refusal to perform patient handling tasks believed to involve unacceptable risks of injury to a patient or nurse. Manually lifting patients has been called deplorable, inefficient, dangerous to nurses, and painful and brutal to patients; manual lifting can cause needless suffering and injury to patients, with dangers including pain, bruising, skin tears, abrasions, tube dislodgement, dislocations, fractures, and being dropped by nursing staff during attempts to manually lift. Use of safe, secure, mechanical lift equipment and gentle friction-reducing devices for patient maneuvering tasks could eliminate such needless brutality. Research has proven that manual patient lifting is extremely hazardous to health-care workers, creating substantial risk of low-back injury, whether with one or two patient handlers. Studies on the use of mechanical patient lift equipment, by either nursing staff or lift teams, have proven repeatedly that most nursing staff back injury is preventable, leading to substantial savings to employers on medical and

  7. Safe handling of tritium

    International Nuclear Information System (INIS)

    1991-01-01

    The main objective of this publication is to provide practical guidance and recommendations on operational radiation protection aspects related to the safe handling of tritium in laboratories, industrial-scale nuclear facilities such as heavy-water reactors, tritium removal plants and fission fuel reprocessing plants, and facilities for manufacturing commercial tritium-containing devices and radiochemicals. The requirements of nuclear fusion reactors are not addressed specifically, since there is as yet no tritium handling experience with them. However, much of the material covered is expected to be relevant to them as well. Annex III briefly addresses problems in the comparatively small-scale use of tritium at universities, medical research centres and similar establishments. However, the main subject of this publication is the handling of larger quantities of tritium. Operational aspects include designing for tritium safety, safe handling practice, the selection of tritium-compatible materials and equipment, exposure assessment, monitoring, contamination control and the design and use of personal protective equipment. This publication does not address the technologies involved in tritium control and cleanup of effluents, tritium removal, or immobilization and disposal of tritium wastes, nor does it address the environmental behaviour of tritium. Refs, figs and tabs

  8. Development of Safe Food Handling Guidelines for Korean Consumers.

    Science.gov (United States)

    Kang, Hee-Jin; Lee, Min-Woo; Hwang, In-Kyeong; Kim, Jeong-Weon

    2015-08-01

    The purpose of this study was to develop guidelines for Korean consumers with regard to safe food handling practices at home by identifying current food handling issues. Korean consumers' behaviors regarding their safe food handling were identified via survey questionnaires that included items on individual hygiene practices, prepreparation steps when cooking, the cooking process, and the storage of leftover foods. The subjects were 417 Korean parents with elementary school children living in Seoul and Gyeonggi Province in the central area of Korea. The survey results revealed gaps between the knowledge or practices of Korean consumers and scientific evidence pertaining to safe food handling practices. Based on these findings, a leaflet on safe food handling guidelines was developed in accordance with Korean food culture. These guidelines suggest personal hygiene practices as well as fundamental principles and procedures for safe food handling from the stage of food purchase to that of keeping leftover dishes. A pilot application study with 50 consumers revealed that the guidelines effectively improved Korean consumers' safe food handling practices, suggesting that they can serve as practical educational material suitable for Korean consumers.

  9. Safe handling of radiation sources

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    This chapter discussed the subjects related to the safe handling of radiation sources: type of radiation sources, method of use: transport within premises, transport outside premises; Disposal of Gamma Sources

  10. Factors influencing oncology nurses' use of hazardous drug safe-handling precautions.

    Science.gov (United States)

    Polovich, Martha; Clark, Patricia C

    2012-05-01

    To examine relationships among factors affecting nurses' use of hazardous drug (HD) safe-handling precautions, identify factors that promote or interfere with HD precaution use, and determine managers' perspectives on the use of HD safe-handling precautions. Cross-sectional, mixed methods; mailed survey to nurses who handle chemotherapy and telephone interviews with managers. Mailed invitation to oncology centers across the United States. 165 nurses who reported handling chemotherapy and 20 managers of nurses handling chemotherapy. Instruments measured the use of HD precautions and individual and organizational factors believed to influence precaution use. Data analysis included descriptive statistics and hierarchical regression. Manager interview data were analyzed using content analysis. Chemotherapy exposure knowledge, self-efficacy, perceived barriers, perceived risk, interpersonal influences, and workplace safety climate. Nurses were well educated, experienced, and certified in oncology nursing. The majority worked in outpatient settings and administered chemotherapy to an average of 6.8 patients per day. Exposure knowledge, self-efficacy for using personal protective equipment, and perceived risk of harm from HD exposure were high; total precaution use was low. Nurse characteristics did not predict HD precaution use. Fewer barriers, better workplace safety climate, and fewer patients per day were independent predictors of higher HD precaution use. HD handling policies were present, but many did not reflect current recommendations. Few managers formally monitored nurses' HD precaution use. Circumstances in the workplace interfere with nurses' use of HD precautions. Interventions should include fostering a positive workplace safety climate, reducing barriers, and providing appropriate nurse-patient ratios.

  11. [The Necessity and the Current Status of Safe Handling of Anticancer Drugs].

    Science.gov (United States)

    Kanda, Kiyoko

    2017-07-01

    Number of people who handle anticancer drugs in their profession is increasing. Anticancer drugs, which are hazardous drugs(HD), exert cytocidal effects on cancer cells, but many have also been shown to have mutagenicity, teratogenicity and carcinogenicity; therefore, safe handling of anticancer drugs is necessary. In July 2015, the first Japanese guidelines for exposure control measures, namely, the "Joint Guidelines for Safe Handling of Cancer Chemotherapy Drugs", were published jointly by 3 societies. Our guideline is the creation of the Japanese Society of Cancer Nursing(JSCN), Japanese Society of Medical Oncology(JSMO)and Japanese Society of Pharmaceutical Oncology(JASPO)and has a historical significance. This paper states the necessity of safe handling of anticancer drugs, Japan's recent movement of safe handling, the introduction of joint guidelines of safe handling of anticancer drugs, and new movement of safe handling of USP chapter 800 in the United States.

  12. Plutonium safe handling

    International Nuclear Information System (INIS)

    Tvehlov, Yu.

    2000-01-01

    The abstract, prepared on the basis of materials of the IAEA new leadership on the plutonium safe handling and its storage (the publication no. 9 in the Safety Reports Series), aimed at presenting internationally acknowledged criteria on the radiation danger evaluation and summarizing the experience in the safe management of great quantities of plutonium, accumulated in the nuclear states, is presented. The data on the weapon-class and civil plutonium, the degree of its danger, the measures for provision of its safety, including the data on accident radiation consequences with the fission number 10 18 , are presented. The recommendations, making it possible to eliminate the super- criticality danger, as well as ignition and explosion, to maintain the tightness of the facility, aimed at excluding the radioactive contamination and the possibility of internal irradiation, to provide for the plutonium security, physical protection and to reduce irradiation are given [ru

  13. Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Best, Lawrence Mj; Tanguay, Cynthia; Lennan, Elaine; Korva, Mika; Bussières, Jean-François

    2018-03-27

    between CSTD and control groups in the pharmacy areas or patient-care areas.None of the studies report on atmospheric contamination, blood tests, or other measures of exposure to infusional hazardous drugs such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, or micronuclei induction.None of the studies report short-term health benefits such as reduction in skin rashes, medium-term reproductive health benefits such as fertility and parity, or long-term health benefits related to the development of any type of cancer or adverse events.Five studies (six hospitals) report the potential cost savings through the use of CSTD. The studies used different methods of calculating the costs, and the results were not reported in a format that could be pooled via meta-analysis. There is significant variability between the studies in terms of whether CSTD resulted in cost savings (the point estimates of the average potential cost savings ranged from (2017) USD -642,656 to (2017) USD 221,818). There is currently no evidence to support or refute the routine use of closed-system drug transfer devices in addition to safe handling of infusional hazardous drugs, as there is no evidence of differences in exposure or financial benefits between CSTD plus safe handling versus safe handling alone (very low-quality evidence). None of the studies report health benefits.Well-designed multicentre randomised controlled trials may be feasible depending upon the proportion of people with exposure. The next best study design is interrupted time-series. This design is likely to provide a better estimate than uncontrolled before-after studies or cross-sectional studies. Future studies may involve other alternate ways of reducing exposure in addition to safe handling as one intervention group in a multi-arm parallel design or factorial design trial. Future studies should have designs that decrease the risk of bias and enable measurement of direct health benefits in addition to

  14. A multi-component patient-handling intervention improves attitudes and behaviors for safe patient handling and reduces aggression experienced by nursing staff

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Casper, Sven Dalgas; Andersen, Lars L.

    2017-01-01

    This study evaluated an intervention for patient-handling equipment aimed to improve nursing staffs' use of patient handling equipment and improve their general health, reduce musculoskeletal problems, aggressive episodes, days of absence and work-related accidents. As a controlled before......-after study, questionnaire data were collected at baseline and 12-month follow-up among nursing staff at intervention and control wards at two hospitals. At 12-month follow-up, the intervention group had more positive attitudes towards patient-handling equipment and increased use of specific patient......-handling equipment. In addition, a lower proportion of nursing staff in the intervention group had experienced physically aggressive episodes. No significant change was observed in general health status, musculoskeletal problems, days of absence or work-related accidents. The intervention resulted in more positive...

  15. Procedure of safe handling with cytostatic drugs

    Directory of Open Access Journals (Sweden)

    Kodžo Dragan

    2003-01-01

    Full Text Available Working group for safe handling with cytostatic drugs has been formed by the Ministry of Health, and it consists of professionals from IORS, Federal Bureau of Weights and Measures, Industrial Medicine, Institute of Hematology, Military Medical Academy, and Crown Agents. The aim of this working group is to prepare procedures for safe handling with cytostatic drugs, as well as program for educational seminar for nurses, medical technicians, and pharmaceutical technicians. The procedures will serve as a guide of good practice of oncology health care, and will refer to all actions that health care professionals carry out from the moment of drugs arrival to the pharmacy to the moment of their application. In the first segment of this procedure, general rules are given for working with cytotoxic agents, control for risky exposures, safe system of work, control of working environment, monitoring of the employees' health condition adequate protection in the working environment, protective equipment of the employees (gloves, mask, cap, eyeglasses, shoe covers, coats and chambers for vertical laminary air stream. Storing of cytostatics, procedure in case of accident, and waste handling and removal are also described in this segment. Fifty-three standard operational procedures are described in detail in the second segment. Training scheme for preparation of chemotherapy is given in the third segment - education related to various fields and practical part, which would be carried out through workshops, and at the end of the course participants would pass a test and obtain certificate. After the procedures for safe handling with cytostatics are legally regulated employer will have to provide minimum of protective equipment, special rooms for the drugs dissolving, chambers with laminar airflow, 6 hours working time, rotation of the staff working with drugs dissolving in intervals of every five years, higher efficiency, better health control. In conclusion

  16. Recent progress on developments of tritium safe handling techniques in Japan

    International Nuclear Information System (INIS)

    Watanabe, Kuniaki; Matsuyama, Masao

    1993-01-01

    Vast amounts of tritium will be used for thermonuclear fusion reactors. Without establishing safe handling techniques for large amounts of tritium, undoubtedly the fusion reactors will not be accepted. Japanese activity on tritium related research has considerably developed in the last 10 years. This review paper gives a brief summary of safe handling techniques developed by Japanese research groups. (author)

  17. Safe handling of potential peroxide forming compounds and their corresponding peroxide yielded derivatives.

    Energy Technology Data Exchange (ETDEWEB)

    Sears, Jeremiah Matthew; Boyle, Timothy J.; Dean, Christopher J.

    2013-06-01

    This report addresses recent developments concerning the identification and handling of potential peroxide forming (PPF) and peroxide yielded derivative (PYD) chemicals. PPF chemicals are described in terms of labeling, shelf lives, and safe handling requirements as required at SNL. The general peroxide chemistry concerning formation, prevention, and identification is cursorily presented to give some perspective to the generation of peroxides. The procedure for determining peroxide concentrations and the proper disposal methods established by the Hazardous Waste Handling Facility are also provided. Techniques such as neutralization and dilution are provided for the safe handling of any PYD chemicals to allow for safe handling. The appendices are a collection of all available SNL documentation pertaining to PPF/PYD chemicals to serve as a single reference.

  18. Safe handling of plutonium: a panel report

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    This guide results from a meeting of a Panel of Experts held by the International Atomic Energy Agency on 8 to 12 November 1971. It is directed to workers in research laboratories handling plutonium in gram amounts. Contents: aspects of the physical and chemical properties of plutonium; metabolic features of plutonium; facility design features for safe handling of plutonium (layout of facility, working zones, decontamination room, etc.); glove boxes; health surveillance (surveillance of environment and supervision of workers); emergencies; organization. Annexes: types of glove boxes; tables; mobile ..cap alpha.. air sampler; aerosol monitor; bio-assay limits of detection; examples of contamination control monitors.

  19. Safe handling of plutonium in research laboratories

    International Nuclear Information System (INIS)

    1976-01-01

    The training film illustrates the main basic requirements for the safe handling of small amounts of plutonium. The film is intended not only for people setting up plutonium research laboratories but also for all those who work in existing plutonium research laboratories. It was awarded the first prize in the category ''Protection of Workers'' at the international film festival organized by the 4th World Congress of the International Radiation Protection Association (IRPA) in Paris in April 1977

  20. Safe handling of plutonium in research laboratories

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-12-31

    The training film illustrates the main basic requirements for the safe handling of small amounts of plutonium. The film is intended not only for people setting up plutonium research laboratories but also for all those who work in existing plutonium research laboratories. It was awarded the first prize in the category ``Protection of Workers`` at the international film festival organized by the 4th World Congress of the International Radiation Protection Association (IRPA) in Paris in April 1977

  1. Food Safety Posters for Safe Handling of Leafy Greens

    Science.gov (United States)

    Rajagopal, Lakshman; Arendt, Susan W.; Shaw, Angela M.; Strohbehn, Catherine H.; Sauer, Kevin L.

    2016-01-01

    This article describes food safety educational tools depicting safe handling of leafy greens that are available as downloadable posters to Extension educators and practitioners (www.extension.iastate.edu). Nine visual-based minimal-text colored posters in English, Chinese, and Spanish were developed for use when formally or informally educating…

  2. An exploration of undergraduate nursing and physiotherapy students' views regarding education for patient handling.

    Science.gov (United States)

    Kneafsey, Rosie; Ramsay, Jill; Edwards, Helen; Callaghan, Helen

    2012-12-01

    To ascertain the views of undergraduate student nurses and physiotherapists regarding their education in patient handling. Musculo-skeletal injuries are an important cause of staff sickness absence and attrition from the nursing profession and are a recognised problem within the physiotherapy profession. Nurses and physiotherapists are at risk of musculo-skeletal injuries as a result of their role in assisting patients with movement. A questionnaire survey was undertaken of undergraduate nursing and physiotherapy students (n = 371) at one university. Most students agreed that university teaching about moving and handling prepared them for clinical practice (64%). Over a third reported that they had never undertaken a written moving and handling risk assessment in clinical practice (38%). Almost half of the sample (40%) admitted undertaking unsafe moving and handling activities. Half (50%) also stated that they would rather 'fit' into the team than challenge unsafe practice. Almost a third (29%) stated that they had begun to experience pain since becoming a student. There were significant differences between nursing and physiotherapy students. Physiotherapy students were more likely to report being supervised when moving and handling and reported being more assertive about adhering to safe practice. The well-being of both nursing and physiotherapy undergraduate students is threatened when students undertake work placements in clinical settings. University-based education in safe patient handling, though important, can be undermined by workplace settings where unsafe practices occur. Collaboration is needed between university educators, managers and practice-based mentors to support students to maintain safe approaches to moving and handling patients. A third of students reported developing pain since becoming a healthcare student. Students entering their professions already injured may leave the workforce owing to poor physical well-being. It is vital that the

  3. American Nurses Association position statement on elimination of manual patient handling to prevent work-related musculoskeletal disorders.

    Science.gov (United States)

    In order to establish a safe environment for nurses and patients, the American Nurses Association (ANA) supports actions and policies that result in the elimination of manual patient handling. Patient handling, such as lifting, repositioning, and transferring, has conventionally been performed by nurses. The performance of these tasks exposes nurses to increased risk for work-related musculoskeletal disorders. With the development of assistive equipment, such as lift and transfer devices, the risk of musculoskeletal injury can be significantly reduced. Effective use of assistive equipment and devices for patient handling creates a safe healthcare environment by separating the physical burden from the nurse and ensuring the safety, comfort, and dignity of the patient.

  4. Code of practice for the control and safe handling of radioactive sources used for therapeutic purposes (1988)

    International Nuclear Information System (INIS)

    1988-01-01

    This Code is intended as a guide to safe practices in the use of sealed and unsealed radioactive sources and in the management of patients being treated with them. It covers the procedures for the handling, preparation and use of radioactive sources, precautions to be taken for patients undergoing treatment, storage and transport of radioactive sources within a hospital or clinic, and routine testing of sealed sources [fr

  5. Safe Handling of Radioisotopes

    International Nuclear Information System (INIS)

    1958-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it has been considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. Such a manual is presented here and represents the first of a series of manuals and codes to be issued by the Agency. It has been prepared after careful consideration of existing national and international codes of radiation safety, by a group of international experts and in consultation with other international bodies. At the same time it is recommended that the manual be taken into account as a basic reference document by Member States of the Agency in the preparation of national health and safety documents covering the use of radioisotopes.

  6. Explaining Consumer Safe Food Handling Through Behavior-Change Theories: A Systematic Review.

    Science.gov (United States)

    Young, Ian; Reimer, Danielle; Greig, Judy; Meldrum, Richard; Turgeon, Patricia; Waddell, Lisa

    2017-11-01

    Consumers often engage in unsafe food handling behaviors at home. Previous studies have investigated the ability of behavior-change theories to explain and predict these behaviors. The purpose of this review was to determine which theories are most consistently associated with consumers' safe food handling behaviors across the published literature. A standardized systematic review methodology was used, consisting of the following steps: comprehensive search strategy; relevance screening of identified references; confirmation of relevance and characterization of relevant articles; risk-of-bias assessment; data extraction; and descriptive analysis of study results. A total of 20 relevant studies were identified; they were mostly conducted in Australia (40%) and the United States (35%) and used a cross-sectional design (65%). Most studies targeted young adults (65%), and none focused on high-risk consumer groups. The outcomes of 70% of studies received high overall risk-of-bias ratings, largely due to a lack of control for confounding variables. The most commonly applied theory was the Theory of Planned Behavior (45% of studies), which, along with other investigated theories of behavior change, was frequently associated with consumer safe food handling behavioral intentions and behaviors. However, overall, there was wide variation in the specific constructs found to be significantly associated and in the percentage of variance explained in each outcome across studies. The results suggest that multiple theories of behavior change can help to explain consumer safe food handling behaviors and could be adopted to guide the development of future behavior-change interventions. In these contexts, theories should be appropriately selected and adapted to meet the needs of the specific target population and context of interest.

  7. Safe handling of cytotoxic compounds in a biopharmaceutical environment.

    Science.gov (United States)

    Hensgen, Miriam I; Stump, Bernhard

    2013-01-01

    Handling cytotoxic drugs such as antibody-drug conjugates (ADCs) in a biopharmaceutical environment represents a challenge based on the potency of the compounds. These derivatives are dangerous to humans if they accidentally get in contact with the skin, are inhaled, or are ingested, either as pure compounds in their solid state or as a solution dissolved in a co-solvent. Any contamination of people involved in the manufacturing process has to be avoided. On the other hand, biopharmaceuticals need to be protected simultaneously against any contamination from the manufacturing personnel. Therefore, a tailor-made work environment is mandatory in order to manufacture ADCs. This asks for appropriate technical equipment to keep potential hazardous substances contained. In addition, clearly defined working procedures based on risk assessments as well as proper training for all personnel involved in the manufacturing process are needed to safely handle these highly potent pharmaceuticals.

  8. Gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of malaysia.

    Science.gov (United States)

    Bin Nordin, R; Araki, S; Sato, H; Yokoyama, K; Bin Wan Muda, W A; Win Kyi, D

    2001-01-01

    To identify gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of Malaysia, we conducted a 20-item questionnaire interview on storage of pesticide (4 questions), mixing of pesticide (3 questions), use of personal protective equipment and clothing while spraying pesticide (7 questions), activities during and after spraying of pesticide (5 questions), and maintenance of pesticide sprayer (1 question) in 496 tobacco farmers (395 males and 101 females) in Bachok District, Kelantan, Malaysia. Duration of employment was significantly longer in females than those in males (pwork habit, (3) reading and following instructions on pesticide label, (4) security, storage and disposal of pesticide container, (5) safe work habit, (6) proper handling of pesticide and maintenance of pesticide sprayer, (7) use of personal protective clothing, and (8) safe handling of pesticide. Results of analysis of covariance for the eight factor scores of all male and female farmers, controlling for educational level and duration of employment, showed that: (1) factor scores for use of personal protective equipment (pwork habit (p0.05). We therefore conclude that: (1) for female tobacco farmers, choice of personal attire tend to result in lower scores on use of personal protective equipment and personal protective clothing while personal hygiene practices result in lower score on safe work habit; and, (2) for male tobacco farmers, the lower scores on reading and following instruction on pesticide label and mixing pesticide and maintenance of pesticide sprayer in good condition suggests that they were not primarily involved in these activities. It is postulated that these differences in safe and unsafe practices of pesticide handling across gender is related to the choice of personal attire, personal hygiene practices and division of labour within farming households which in turn is influenced by prevailing sociocultural norms in the community.

  9. Ergonomics and patient handling.

    Science.gov (United States)

    McCoskey, Kelsey L

    2007-11-01

    This study aimed to describe patient-handling demands in inpatient units during a 24-hour period at a military health care facility. A 1-day total population survey described the diverse nature and impact of patient-handling tasks relative to a variety of nursing care units, patient characteristics, and transfer equipment. Productivity baselines were established based on patient dependency, physical exertion, type of transfer, and time spent performing the transfer. Descriptions of the physiological effect of transfers on staff based on patient, transfer, and staff characteristics were developed. Nursing staff response to surveys demonstrated how patient-handling demands are impacted by the staff's physical exertion and level of patient dependency. The findings of this study describe the types of transfers occurring in these inpatient units and the physical exertion and time requirements for these transfers. This description may guide selection of the most appropriate and cost-effective patient-handling equipment required for specific units and patients.

  10. Nuclear hydrogen production and its safe handling

    International Nuclear Information System (INIS)

    Chung, Hongsuk; Paek, Seungwoo; Kim, Kwang-Rag; Ahn, Do-Hee; Lee, Minsoo; Chang, Jong Hwa

    2003-01-01

    An overview of the hydrogen related research presently undertaken at the Korea Atomic Energy Research Institute are presented. These encompass nuclear hydrogen production, hydrogen storage, and the safe handling of hydrogen, High temperature gas-cooled reactors can play a significant role, with respect to large-scale hydrogen production, if used as the provider of high temperature heat in fossil fuel conversion or thermochemical cycles. A variety of potential hydrogen production methods for high temperature gas-cooled reactors were analyzed. They are steam reforming of natural gas, thermochemical cycles, etc. The produced hydrogen should be stored safely. Titanium metal was tested primarily because its hydride has very low dissociation pressures at normal storage temperatures and a high capacity for hydrogen, it is easy to prepare and is non-reactive with air in the expected storage conditions. There could be a number of potential sources of hydrogen evolution risk in a nuclear hydrogen production facility. In order to reduce the deflagration detonation it is necessary to develop hydrogen control methods that are capable of dealing with the hydrogen release rate. A series of experiments were conducted to assess the catalytic recombination characteristics of hydrogen in an air stream using palladium catalysts. (author)

  11. Safe meat-handling knowledge, attitudes and practices of private and government meat processing plants' workers: implications for future policy.

    Science.gov (United States)

    Adesokan, H K; Raji, A O Q

    2014-03-01

    Food-borne disease outbreaks remain a major global health challenge and cross-contamination from raw meat due to poor handling is a major cause in developing countries. Adequate knowledge of meat handlers is important in limiting these outbreaks. This study evaluated and compared the safe meat-handling knowledge, attitudes and practices (KAP) of private (PMPP) and government meat processing plants' (GMPP) workers in south-western Nigeria. This cross sectional study comprised 190 meat handlers (PMPP = 55; GMPP = 135). Data concerning their safe meat-handling knowledge, attitudes and practices as well as their socio-demographic characteristics, such as age, gender and work experience were collected. A significant association was observed between the type of meat processing plants and their knowledge (p = 0.000), attitudes (p = 0.000) and practices (p = 0.000) of safe meat-handling. Meat handlers in the GMPP were respectively, about 17 times (OR = 0.060, 95% CI: 0.018-0.203), 57 times (OR = 0.019, 95% CI: 0.007-0.054) and 111 times (OR = 0.009, 95% CI: 0.001- 0.067) less likely to obtain good knowledge, attitude and practice level of safe meat-handling than those from PMPP. Further, KAP levels were significantly associated with age group, education and work experience (p < 0.05). Study findings suggest the need for future policy in food industry in developing countries to accommodate increased involvement of private sector for improved food safety and quality delivery. Public health education on safe food handling and hygiene should be on the front burner among food handlers in general.

  12. 76 FR 59661 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2011-09-27

    ...; Charleston, SC; and Madeira Beach, FL. The Protected Species Safe Handling, Release, and Identification....-4 p.m., Madeira Beach City Hall, 300 Municipal Drive, Madeira Beach, FL 33708. Registration To...

  13. Guidelines for safe handling of hazardous drugs: A systematic review.

    Science.gov (United States)

    Bernabeu-Martínez, Mari A; Ramos Merino, Mateo; Santos Gago, Juan M; Álvarez Sabucedo, Luis M; Wanden-Berghe, Carmina; Sanz-Valero, Javier

    2018-01-01

    To review the scientific literature related to the safe handling of hazardous drugs (HDs). Critical analysis of works retrieved from MEDLINE, the Cochrane Library, Scopus, CINHAL, Web of Science and LILACS using the terms "Hazardous Substances", "Antineoplastic Agents" and "Cytostatic Agents", applying "Humans" and "Guidelines" as filters. Date of search: January 2017. In total, 1100 references were retrieved, and from those, 61 documents were selected based on the inclusion and exclusion criteria: 24 (39.3%) documents related to recommendations about HDs; 27 (44.3%) about antineoplastic agents, and 10 (33.3%) about other types of substances (monoclonal antibodies, gene medicine and other chemical and biological agents). In 14 (23.3%) guides, all the stages in the manipulation process involving a risk due to exposure were considered. Only one guide addressed all stages of the handling process of HDs (including stages with and without the risk of exposure). The most described stages were drug preparation (41 guides, 67.2%), staff training and/or patient education (38 guides, 62.3%), and administration (37 guides, 60.7%). No standardized informatics system was found that ensured quality management, traceability and minimization of the risks associated with these drugs. Most of the analysed guidelines limit their recommendations to the manipulation of antineoplastics. The most frequently described activities were preparation, training, and administration. It would be convenient to apply ICTs (Information and Communications Technologies) to manage processes involving HDs in a more complete and simpler fashion.

  14. Safe handling of renewable fuels and fuel mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Wilen, C; Rautalin, A [VTT Energy, Espoo (Finland)

    1997-12-01

    VTT Energy has for several years carried out co-operation with many European research institutes on contractional basis on safety issues of fuels handling. A two-year co-operational project between VTT Energy and these research institutes was started in EU`s JOULE 3 programme in 1996, the total budget of which is 6.9 million FIM. Dust explosion testing method for `difficult` fuels, and for tests at elevated pressures and temperatures, will be developed in the task `Safe handling of renewable fuels and fuel mixtures`. Self- ignition and dust-explosion characteristics will be generated for wood and agro-biomass based biomasses and for the mixtures of them and coal. Inertization requirements will be studied, and the quenching method, combined with partial inertization, will be tested in 1.0 m{sup 3} test equipment. The ignition properties of the fuels under normal and elevated pressures will be characterised with thermobalances. The self-ignition tests with wood and forest residue dusts at 25 bar pressure have been carried out as scheduled. In addition to this, several fuels have undergone thermobalance tests, sieve analyses and microscopic studies for the characterisation of the fuels

  15. A physical workload index to evaluate a safe resident handling program for nursing home personnel.

    Science.gov (United States)

    Kurowski, Alicia; Buchholz, Bryan; Punnett, Laura

    2014-06-01

    The aim of this study was to obtain a comprehensive analysis of the physical workload of clinical staff in long-term care facilities, before and after a safe resident handling program (SRHP). Ergonomic exposures of health care workers include manual handling of patients and many non-neutral postures. A comprehensive assessment requires the integration of loads from these varied exposures into a single metric. The Postures, Activities, Tools, and Handling observational protocol, customized for health care, was used for direct observations of ergonomic exposures in clinical jobs at 12 nursing homes before the SRHP and 3, 12, 24, and 36 months afterward. Average compressive forces on the spine were estimated for observed combinations of body postures and manual handling and then weighted by frequencies of observed time for the combination. These values were summed to obtain a biomechanical index for nursing assistants and nurses across observation periods. The physical workload index (PWI) was much higher for nursing assistants than for nurses and decreased more after 3 years (-24% versus -2.5%). Specifically during resident handling, the PWI for nursing assistants decreased by 41% of baseline value. Spinal loading was higher for nursing assistants than for nurses in long-term care centers. Both job groups experienced reductions in physical loading from the SRHP, especially the nursing assistants and especially while resident handling. The PWI facilitates a comprehensive investigation of physical loading from both manual handling and non-neutral postures. It can be used in any work setting to identify high-risk tasks and determine whether reductions in one exposure are offset by increases in another.

  16. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies.

    Directory of Open Access Journals (Sweden)

    Ian Young

    Full Text Available Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers' perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11, moderate (11, and low (9. Overarching analytical themes included: 1 safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2 most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3 consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed.

  17. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies

    Science.gov (United States)

    Young, Ian; Waddell, Lisa

    2016-01-01

    Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers’ perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11), moderate (11), and low (9). Overarching analytical themes included: 1) safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2) most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3) consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed. PMID:27907161

  18. Safe Handling of Radioisotopes. Medical Addendum

    International Nuclear Information System (INIS)

    Hercik, F.; Jammet, H.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains information necessary to medical officers concerned with the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the medical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  19. Safe handling of radioactive isotopes. Handbook 42

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1949-09-15

    With the increasing use of radioactive isotopes by industry, the medical profession, and research laboratories, it is essential that certain minimal precautions be taken to protect the users and the public. The recommendations contained in this handbook represent what is believed to be the best available opinions on the subject as of this date. As our experience with radioisotopes broadens, we will undoubtedly be able to improve and strengthen the recommendations for their safe handling and utilization. Through the courtesy of the National Research Council about a year ago, several hundred draft copies of this report were circulated to all leading workers and authorities in the field for comment and criticism. The present handbook embodies all pertinent suggestions received from these people. Further comment will be welcomed by the committee. One of the greatest difficulties encountered in the preparation of this handbook lay in the uncertainty regarding permissible radiation exposure levels - particularly for ingested radioactive materials. The establishment of sound figures for such exposure still remains a problem of high priority for many conditions and radioactive substances. Such figures as are used in this report represent the best available information today. If, in the future, these can be improved upon, appropriate corrections will be issued. The subject will be under continuous study by the two subcommittees mentioned above. The present Handbook has been prepared by the Subcommittee on the Handling of Radioactive Isotopes and Fission Products.

  20. Safe handling of radioactive isotopes. Handbook 42

    International Nuclear Information System (INIS)

    1949-09-01

    With the increasing use of radioactive isotopes by industry, the medical profession, and research laboratories, it is essential that certain minimal precautions be taken to protect the users and the public. The recommendations contained in this handbook represent what is believed to be the best available opinions on the subject as of this date. As our experience with radioisotopes broadens, we will undoubtedly be able to improve and strengthen the recommendations for their safe handling and utilization. Through the courtesy of the National Research Council about a year ago, several hundred draft copies of this report were circulated to all leading workers and authorities in the field for comment and criticism. The present handbook embodies all pertinent suggestions received from these people. Further comment will be welcomed by the committee. One of the greatest difficulties encountered in the preparation of this handbook lay in the uncertainty regarding permissible radiation exposure levels - particularly for ingested radioactive materials. The establishment of sound figures for such exposure still remains a problem of high priority for many conditions and radioactive substances. Such figures as are used in this report represent the best available information today. If, in the future, these can be improved upon, appropriate corrections will be issued. The subject will be under continuous study by the two subcommittees mentioned above. The present Handbook has been prepared by the Subcommittee on the Handling of Radioactive Isotopes and Fission Products

  1. 75 FR 29991 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2010-05-28

    ... Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and Identification... (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., August, and September of 2010. Certain fishermen and shark dealers are required to attend a workshop to...

  2. 78 FR 73500 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2013-12-06

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., February, and March of 2014. Certain fishermen and shark dealers are required to attend a workshop to meet...

  3. 78 FR 54456 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2013-09-04

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., November, and December of 2013. Certain fishermen and shark dealers are required to attend a workshop to...

  4. 77 FR 32950 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2012-06-04

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., August, and September of 2012. Certain fishermen and shark dealers are required to attend a workshop to...

  5. 75 FR 10217 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2010-03-05

    ... Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and Identification... (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: NMFS announces free Atlantic Shark... April, May, and June of 2010. Certain fishermen and shark dealers are required to attend a workshop to...

  6. 75 FR 8304 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2010-02-24

    ... Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and Identification... gear, and have also been issued shark or swordfish limited access permits. Additional free workshops... Coastal Highway, Ocean City, MD 21842. Atlantic Shark Identification Workshop Since January 1, 2007, shark...

  7. 77 FR 12574 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2012-03-01

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., May, and June of 2012. Certain fishermen and shark dealers are required to attend a workshop to meet...

  8. 77 FR 55464 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2012-09-10

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., November, and December of 2012. Certain fishermen and shark dealers are required to attend a workshop to...

  9. 77 FR 73451 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2012-12-10

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., February, and March of 2013. Certain fishermen and shark dealers are required to attend a workshop to meet...

  10. 78 FR 15709 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2013-03-12

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., May, and June of 2013. Certain fishermen and shark dealers are required to attend a workshop to meet...

  11. 75 FR 74693 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2010-12-01

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., February, and March of 2011. Certain fishermen and shark dealers are required to attend a workshop to meet...

  12. 76 FR 34209 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2011-06-13

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., August, and September of 2011. Certain fishermen and shark dealers are required to attend a workshop to...

  13. 76 FR 77214 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2011-12-12

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., February, and March of 2012. Certain fishermen and shark dealers are required to attend a workshop to meet...

  14. 76 FR 11762 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2011-03-03

    ... for Atlantic Shark Identification Workshops and Protected Species Safe Handling, Release, and... Administration (NOAA), Commerce. ACTION: Notice of public workshops. SUMMARY: Free Atlantic Shark Identification..., May, and June of 2011. Certain fishermen and shark dealers are required to attend a workshop to meet...

  15. Safe Handling of Radioisotopes. Health Physics Addendum

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, G J; Krishnamoorthy, P N

    1960-07-15

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  16. Safe Handling of Radioisotopes. Health Physics Addendum

    International Nuclear Information System (INIS)

    Appleton, G.J.; Krishnamoorthy, P.N.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  17. System design for safe robotic handling of nuclear materials

    International Nuclear Information System (INIS)

    Drotning, W.; Wapman, W.; Fahrenholtz, J.; Kimberly, H.; Kuhlmann, J.

    1996-01-01

    Robotic systems are being developed by the Intelligent Systems and Robotics Center at Sandia National Laboratories to perform automated handling tasks with radioactive nuclear materials. These systems will reduce the occupational radiation exposure to workers by automating operations which are currently performed manually. Because the robotic systems will handle material that is both hazardous and valuable, the safety of the operations is of utmost importance; assurance must be given that personnel will not be harmed and that the materials and environment will be protected. These safety requirements are met by designing safety features into the system using a layered approach. Several levels of mechanical, electrical and software safety prevent unsafe conditions from generating a hazard, and bring the system to a safe state should an unexpected situation arise. The system safety features include the use of industrial robot standards, commercial robot systems, commercial and custom tooling, mechanical safety interlocks, advanced sensor systems, control and configuration checks, and redundant control schemes. The effectiveness of the safety features in satisfying the safety requirements is verified using a Failure Modes and Effects Analysis. This technique can point out areas of weakness in the safety design as well as areas where unnecessary redundancy may reduce the system reliability

  18. 75 FR 53665 - Schedules for Atlantic Shark Identification Workshops and Protected Species Safe Handling...

    Science.gov (United States)

    2010-09-01

    ..., FL; Madeira Beach, FL; and Charleston, SC. The Protected Species Safe Handling, Release, and... Community Center, 504 Big Tree Road, South Daytona, FL 32119. 3. November 3, 2010, 12 p.m. - 4 p.m., Madeira Beach Town Hall, 300 Municipal Drive, Madeira Beach, FL 33708. 4. December 2, 2010, 12 p.m. - 4 p.m...

  19. Peer coaching and mentoring: a new model of educational intervention for safe patient handling in health care.

    Science.gov (United States)

    Alamgir, Hasanat; Drebit, Sharla; Li, Helen Guiyun; Kidd, Catherine; Tam, Helen; Fast, Catherine

    2011-08-01

    To reduce the risk of patient handling-related musculoskeletal injury, overhead ceiling lifts have been installed in health care facilities. To increase ceiling lift usage for a variety of patient handling tasks, a peer coaching and mentoring program was implemented among the direct care staff in the long-term care subsector in British Columbia, Canada. They received a 4-day training program on body mechanics, ergonomics, patient-handling techniques, ceiling lift usage, in addition to coaching skills. A questionnaire was administered among staff before and after the intervention to evaluate the program's effectiveness. There were 403 and 200 respondents to the pre-intervention and post-intervention questionnaires. In general, staff perceived the peer-coaching program to be effective. The number of staff who reported to be using ceiling lifts "often and always" went higher from 64.5% to 80.5% (<0.001) after coaching program implementation. Furthermore, staff reported that they were using the ceiling lifts for more types of tasks post-intervention. Staff reported that the peer coaching program has increased their safety awareness at work and confidence in using the ceiling lifts. The findings suggest that this educational model can increase the uptake of mechanical interventions for occupational health and safety initiatives. It appears that the training led to a greater awareness of the availability of or increased perceptions of the number of ceiling lifts, presumably through coaches advocating their use. Copyright © 2011 Wiley-Liss, Inc.

  20. Long-term efficacy of an ergonomics program that includes patient-handling devices on reducing musculoskeletal injuries to nursing personnel.

    Science.gov (United States)

    Garg, Arun; Kapellusch, Jay M

    2012-08-01

    The aim of this study was to evaluate long-term efficacy of an ergonomics program that included patient-handling devices in six long-term care facilities (LTC) and one chronic care hospital (CCH). Patient handling is recognized as a major source of musculoskeletal disorders (MSDs) among nursing personnel, and several studies have demonstrated effectiveness of patient-handling devices in reducing those MSDs. However, most studies have been conducted in a single facility, for a short period, and/or without a comprehensive ergonomics program. Patient-handling devices along with a comprehensive ergonomics program was implemented in six LTC facilities and one CCH. Pre- and postintervention injury data were collected for 38.9 months (range = 29 to 54 months) and 51.2 months (range = 36 to 60 months), respectively. Postintervention patient-handling injuries decreased by 59.8% (rate ratio [RR] = 0.36, 95% confidence interval [CI] [0.28, 0.49], p nursing staff were fairly low. A vast majority of patients found the devices comfortable and safe. Longer transfer times with the use of devices was not an issue. Implementation of patient-handling devices along with a comprehensive program can be effective in reducing MSDs among nursing personnel. Strategies to expand usage of patient-handling devices in most health care settings should be explored.

  1. Safe Handling of Radioisotopes. 1973 Edition

    International Nuclear Information System (INIS)

    1973-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it was considered an urgent task to provide users of radionuclides with a manual of practice for the safe handling of these substances. The first edition of such a manual was published in 1958 and represented the first of the ''Safety Series'', a series of manuals and codes on health and safety published by the Agency. It was prepared after careful consideration of existing national and international codes of radiation safety by a group of international experts and in consultation with other international bodies. This edition presents the second revision. In response to the suggestion made by some Member States, the term 'radioisotopes' has been changed to 'radionuclides' in the title and, as appropriate, in the text because the term 'radionuclides' includes the radioactive element itself as well as the isotopes. The series of manuals and codes published in the Safety Series and the Technical Reports Series give more complete advice to the user on specialized topics.

  2. Differences among nursing homes in outcomes of a safe resident handling program.

    Science.gov (United States)

    Kurowski, Alicia; Gore, Rebecca; Buchholz, Bryan; Punnett, Laura

    2012-01-01

    A large nursing home corporation implemented a safe resident handling program (SRHP) in 2004-2007. We evaluated its efficacy over a 2-year period by examining differences among 5 centers in program outcomes and potential predictors of those differences. We observed nursing assistants (NAs), recording activities and body postures at 60-second intervals on personal digital assistants at baseline and at 3-month, 12-month, and 24-month follow-ups. The two outcomes computed were change in equipment use during resident handling and change in a physical workload index that estimated spinal loading due to body postures and handled loads. Potential explanatory factors were extracted from post-observation interviews, investigator surveys of the workforce, from administrative data, and employee satisfaction surveys. The facility with the most positive outcome measures was associated with many positive changes in explanatory factors and the facility with the fewest positive outcome measures experienced negative changes in the same factors. These findings suggest greater SRHP benefits where there was lower NA turnover and agency staffing; less time pressure; and better teamwork, staff communication, and supervisory support. © 2012 American Society for Healthcare Risk Management of the American Hospital Association.

  3. Safe handling, transport and storage of plutonium. Proceedings of a technical committee meeting held in Vienna, 18-21 October 1993

    International Nuclear Information System (INIS)

    1994-10-01

    Plutonium inventories and utilization rates worldwide are growing. It is important for nuclear power programmes everywhere that no incidents or accidents with plutonium occur. It is therefore important that all who deal with plutonium, do so safely. All those who deal with plutonium should have available the best information on safety handling and storage. Several countries have mature plutonium programmes. However, information exchange on plutonium has been limited. This has precluded the development until now of consensus documentation on safe handling and storage of plutonium. The Technical Committee has been established to address these problems and this Technical Document is the first product in this process. The purpose of the meeting was to bring together experts with significant experience in handling, transporting and storing plutonium; to exchange information and experiences dealing with plutonium at their facilities; to describe their practices (guidelines, procedures, regulations, etc.) for safely dealing with plutonium; to assess the need to develop and publish a consensus plutonium safety practices document(s), and to recommend possible future IAEA activities in this technical area. Refs, figs and tabs

  4. Safe Handling and Use of Flammable and Combustible Materials. Module SH-30. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safe handling and use of flammable and combustible materials is one of 50 modules concerned with job safety and health. This module introduces the student to the hazards of flammable and combustible materials and the measures necessary to control those hazards. Following the introduction, 14 objectives (each keyed to a page…

  5. Varying influences of motivation factors on employees' likelihood to perform safe food handling practices because of demographic differences.

    Science.gov (United States)

    Ellis, Jason D; Arendt, Susan W; Strohbehn, Catherine H; Meyer, Janell; Paez, Paola

    2010-11-01

    Food safety training has been the primary avenue for ensuring food workers are performing proper food handling practices and thus, serving safe food. Yet, knowledge of safe food handling practices does not necessarily result in actual performance of these practices. This research identified participating food service employees' level of agreement with four factors of motivation (internal motivations, communication, reward-punishment, and resources) and determined if respondents with different demographic characteristics reported different motivating factors. Data were collected from 311 food service employees who did not have any supervisory responsibilities. Intrinsic motivation agreement scores were consistently the highest of all four motivational factors evaluated and did not differ across any of the demographic characteristics considered. In contrast, motivation agreement scores for communication, reward-punishment, and resources did differ based on respondents' gender, age, place of employment, job status, food service experience, completion of food handler course, or possession of a food safety certification. In general, respondents agreed that these motivation factors influenced their likelihood to perform various safe food handling procedures. This research begins to illustrate how employees' demographic characteristics influence their responses to various motivators, helping to clarify the complex situation of ensuring safe food in retail establishments. Future research into why employee willingness to perform varies more for extrinsic motivation than for intrinsic motivation could assist food service managers in structuring employee development programs and the work environment, in a manner that aids in improving external motivation (communication, reward-punishment, and resources) and capitalizing on internal motivation.

  6. Work-related musculoskeletal risks associated with nurses and nursing assistants handling overweight and obese patients: A literature review.

    Science.gov (United States)

    Choi, Sang D; Brings, Kathryn

    2015-01-01

    Nurses and nursing assistants are susceptible to work-related musculoskeletal disorders and injuries (WMSDs) due to the increase in overweight and obese patients they are handling on a daily basis. This study aimed to review work-related musculoskeletal hazards and risks associated with handling overweight and obese patients, and summarize the recommended interventions to mitigate musculoskeletal concerns among nurses and nursing assistants. Approximately 350 publications were initially screened and 22 refereed articles were used to synthesize for this study on the bases of inclusion/exclusion relevance and strength of evidence on overweight or obese patient handling. Evidence suggested that the work-related musculoskeletal risks among nurses and nursing assistants included sprains/strains, low back pain, wrist, knee and shoulder injuries. The findings indicated that the WMSD risks increased when nurses and nursing assistants were manually moving or lifting patients, especially when the patients were overweight or obese. The recommended solutions included the lifting/transfer equipment and devices, ergonomic assessments and controls, no-lift policies, and training and education. To alleviate the risk of musculoskeletal disorders and injuries among nurses and nursing assistants handling overweight or obese patients, additional research and development into what safe patient handling interventions suit this growing population needs to be addressed.

  7. Examining the predictive utility of an extended theory of planned behaviour model in the context of specific individual safe food-handling.

    Science.gov (United States)

    Mullan, Barbara; Allom, Vanessa; Sainsbury, Kirby; Monds, Lauren A

    2015-07-01

    In order to minimise the occurrence of food-borne illness, it is recommended that individuals perform safe food-handling behaviours, such as cooking food properly, cleaning hands and surfaces before preparing food, keeping food at the correct temperature, and avoiding unsafe foods. Previous research examining the determinants of safe food-handling behaviour has produced mixed results; however, this may be due to the fact that this research examined these behaviours as a totality, rather than considering the determinants of each behaviour separately. As such, the objective for the present study was to examine the predictors of the four aforementioned safe food-handling behaviours by applying an extended theory of planned behaviour to the prediction of each distinct behaviour. Participants were 170 students who completed theory of planned behaviour measures, with the addition of moral norm and habit strength at time 1, and behaviour measures one week later. While the influence of injunctive and descriptive norm and perceived behavioural control differed between behaviours, it appeared that moral norm was an important predictor of intention to engage in each of the four behaviours. Similarly, habit strength was an important predictor of each of the behaviours and moderated the relationship between intention and behaviour for the behaviour of avoiding unsafe food. The implication of these findings is that examining safe food-handling behaviours separately, rather than as a totality, may result in meaningful distinctions between the predictors of these behaviours. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Compilation of Requirements for Safe Handling of Fluorine and Fluorine-Containing Products of Uranium Hexafluoride Conversion

    International Nuclear Information System (INIS)

    Ferrada, J.J.; Hightower, J.R.; Begovich, J.M.

    2000-01-01

    Public Law (PL) 105--204 requires the U.S. Department of Energy to develop a plan for inclusion in the fiscal year 2000 budget for conversion of the Department's stockpile of depleted uranium hexafluoride (DUF6) to a more stable form over an extended period. The conversion process into a more stable form will produce fluorine compounds (e.g., elemental fluorine or hydrofluoric acid) that need to be handled safely. This document compiles the requirements necessary to handle these materials within health and safety standards, which may apply in order to ensure protection of the environment and the safety and health of workers and the public

  9. DOE handbook: Tritium handling and safe storage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The DOE Handbook was developed as an educational supplement and reference for operations and maintenance personnel. Most of the tritium publications are written from a radiological protection perspective. This handbook provides more extensive guidance and advice on the null range of tritium operations. This handbook can be used by personnel involved in the full range of tritium handling from receipt to ultimate disposal. Compliance issues are addressed at each stage of handling. This handbook can also be used as a reference for those individuals involved in real time determination of bounding doses resulting from inadvertent tritium releases. This handbook provides useful information for establishing processes and procedures for the receipt, storage, assay, handling, packaging, and shipping of tritium and tritiated wastes. It includes discussions and advice on compliance-based issues and adds insight to those areas that currently possess unclear DOE guidance.

  10. DOE handbook: Tritium handling and safe storage

    International Nuclear Information System (INIS)

    1999-03-01

    The DOE Handbook was developed as an educational supplement and reference for operations and maintenance personnel. Most of the tritium publications are written from a radiological protection perspective. This handbook provides more extensive guidance and advice on the null range of tritium operations. This handbook can be used by personnel involved in the full range of tritium handling from receipt to ultimate disposal. Compliance issues are addressed at each stage of handling. This handbook can also be used as a reference for those individuals involved in real time determination of bounding doses resulting from inadvertent tritium releases. This handbook provides useful information for establishing processes and procedures for the receipt, storage, assay, handling, packaging, and shipping of tritium and tritiated wastes. It includes discussions and advice on compliance-based issues and adds insight to those areas that currently possess unclear DOE guidance

  11. Safe practices and financial considerations in using oral chemotherapeutic agents.

    Science.gov (United States)

    Bartel, Sylvia B

    2007-05-01

    Safe handling practices and financial concerns associated with oral chemotherapy in non-traditional settings are discussed. Oral chemotherapy may pose a risk to patients because of a narrow therapeutic index, complex dosing regimen, dispensing by community pharmacists without prescription order review by an oncology pharmacist or nurse, or self-administration in the home or another nontraditional setting, where patient monitoring is infrequent. Errors in prescribing, dispensing, and administration and patient or caregiver misunderstandings are potential problems with the use of oral chemotherapy that need to be addressed when developing safe practices. Changes in Medicare pharmaceutical reimbursement rates and rules need to be monitored because they have the potential to affect patient care and outcomes. Patient assistance programs and advocacy groups can help alleviate financial concerns associated with oral chemotherapy. Consensus guidelines specific to safe handling of oral chemotherapy in the home or other nontraditional setting need to be developed. Also, healthcare providers must understand reimbursement and provide direction to patients when patient assistance programs or advocacy groups can assist with the financial challenges of oral chemotherapy.

  12. Handling small arbovirus vectors safely during biosafety level 3 containment: Culicoides variipennis sonorensis (Diptera:Ceratopogonidae) and exotic bluetongue viruses.

    Science.gov (United States)

    Hunt, G J; Tabachnick, W J

    1996-05-01

    Equipment and procedures are described for biosafety level 3 (BL-3) containment work with small, zoophilic arthropods. BL-3 classified pathogens always must be manipulated in biological safety cabinets. Procedures, including physical barriers and handling methods, that prevent the escape of potentially virus-infected insects are discussed, and the use of a monitoring system for insect security is explained. The inability to recover escaped minute, flying insects poses a major difference from similar work with larger insects, such as mosquitoes. Methods were developed for the safe and secure handling of Culicoides variipennis sonorensis Wirth & Jones infected with exotic bluetongue viruses during BL-3 containment.

  13. Musculoskeletal injuries resulting from patient handling tasks among hospital workers.

    Science.gov (United States)

    Pompeii, Lisa A; Lipscomb, Hester J; Schoenfisch, Ashley L; Dement, John M

    2009-07-01

    The purpose of this study was to evaluate musculoskeletal injuries and disorders resulting from patient handling prior to the implementation of a "minimal manual lift" policy at a large tertiary care medical center. We sought to define the circumstances surrounding patient handling injuries and to identify potential preventive measures. Human resources data were used to define the cohort and their time at work. Workers' compensation records (1997-2003) were utilized to identify work-related musculoskeletal claims, while the workers' description of injury was used to identify those that resulted from patient handling. Adjusted rate ratios were generated using Poisson regression. One-third (n = 876) of all musculoskeletal injuries resulted from patient handling activities. Most (83%) of the injury burden was incurred by inpatient nurses, nurses' aides and radiology technicians, while injury rates were highest for nurses' aides (8.8/100 full-time equivalent, FTEs) and smaller workgroups including emergency medical technicians (10.3/100 FTEs), patient transporters (4.3/100 FTEs), operating room technicians (3.1/100 FTEs), and morgue technicians (2.2/100 FTEs). Forty percent of injuries due to lifting/transferring patients may have been prevented through the use of mechanical lift equipment, while 32% of injuries resulting from repositioning/turning patients, pulling patients up in bed, or catching falling patients may not have been prevented by the use of lift equipment. The use of mechanical lift equipment could significantly reduce the risk of some patient handling injuries but additional interventions need to be considered that address other patient handling tasks. Smaller high-risk workgroups should not be neglected in prevention efforts.

  14. Safe handling of TBP and nitrates in the nuclear process industry

    International Nuclear Information System (INIS)

    Hyder, M.L.

    1994-07-01

    A laboratory and literature study was made of the reactions of tri-n-butyl phosphate (TBP) with nitric acid and nitrates. Its goal was to establish safe conditions for solvent extraction processes involving these chemicals. The damaging explosions at the Tomsk-7 PUREX plant in Russia graphically illustrated the potential hazard involved in such operations. The study has involved a review of prior and contemporary experiments, and new experiments to answer particular questions about these reactions. TBP extracts nitric acid and some metal nitrates from aqueous solutions. The resulting liquid contains both oxidant and reductant, and can react exothermically if heated sufficiently. Safe handling of these potentially reactive materials involves not only limiting the heat generated by the chemical reaction, but also providing adequate heat removal and venting. Specifically, the following recommendations are made to ensure safety: (1) tanks in which TBP-nitrate complexes are or may be present should be adequately vented to avoid pressurization. Data are supplied as a basis for adequacy; (2) chemically degraded TBP, or TBP that has sat a long time in the presence of acids or radiation, should be purified before use in solvent extraction; (3) evaporators in which TBP might be introduced should be operated at a controlled temperature, and their TBP content should be limited; (4) evaporator bottoms that may contain TBP should be cooled under conditions that ensure heat removal. Finally, process design should consider the potential for such reactions, and operators should be made aware of this potential, so that it is considered during training and process operation

  15. From Safe Systems to Patient Safety

    DEFF Research Database (Denmark)

    Aarts, J.; Nøhr, C.

    2010-01-01

    for the third conference with the theme: The ability to design, implement and evaluate safe, useable and effective systems within complex health care organizations. The theme for this conference was "Designing and Implementing Health IT: from safe systems to patient safety". The contributions have reflected...... and implementation of safe systems and thus contribute to the agenda of patient safety? The contributions demonstrate how the health informatics community has contributed to the performance of significant research and to translating research findings to develop health care delivery and improve patient safety......This volume presents the papers from the fourth International Conference on Information Technology in Health Care: Socio-technical Approaches held in Aalborg, Denmark in June 2010. In 2001 the first conference was held in Rotterdam, The Netherlands with the theme: Sociotechnical' approaches...

  16. Adverse risk: a 'dynamic interaction model of patient moving and handling'.

    Science.gov (United States)

    Griffiths, Howard

    2012-09-01

    The aim of the present study was to examine patient adverse events associated with sub-optimal patient moving and handling. Few studies have examined the patient's perspective on adverse risk during manual handling episodes. A narrative review was undertaken to develop the 'Dynamic Interaction Model of Patient Moving and Handling' in an orthopaedic rehabilitation setting, using peer-reviewed publications published in English between 1992 and 2010. Five predominant themes emerged from the narrative review: 'patient's need to know about analgesics prior to movement/ambulation'; 'comfort care'; 'mastery of and acceptance of mobility aids/equipment'; 'psychological adjustment to fear of falling'; and 'the need for movement to prevent tissue pressure damage'. Prevalence of discomfort, pain, falls, pressure sores together with a specific Direct Instrument Nursing Observation (DINO) tool enable back care advisers to measure quality of patient manual handling. Evaluation of patients' use of mobility aids together with fear of falling may be important in determining patients' recovery trajectory. Clinical governance places a responsibility on nurse managers to consider quality of care for their service users. 'Dynamic Interaction Model of Nurse-Patient Moving and Handling' provides back care advisers, clinical risk managers and occupational health managers with an alternative perspective to clinical risk and occupational risk. © 2011 Blackwell Publishing Ltd.

  17. Solutions for Safe Hot Coil Evacuation and Coil Handling in Case of Thick and High Strength Steel

    Directory of Open Access Journals (Sweden)

    Sieberer Stefan

    2016-01-01

    Full Text Available Currently hot rolling plants are entering the market segment for thick gauges and high strength steel grades where the elastic bending property of the strip leads to internal forces in the coil during coiling operation. The strip tends to open. Primetals is investigating several possibilities to facilitate safe coil evacuation and coil handling under spring-back conditions. The contribution includes finite element models of such mechanical solutions. Results of parameter variation and stability limits of case studies are presented in the paper.

  18. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-06-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question "can control banding be useful to ensure adequate controls for the safe handling of nanomaterials." A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included `control,' `hazard,' `exposure,' and `risk' banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended exposure controls using

  19. European Model Code of safe practice in the storage and handling of petroleum products. Part I. Operations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    This safe practice code was prepared by a working group consisting of experts from 10 Western European countries. It consists of short guidelines and technical advice on general precautions, injuries and medical services, permits to work, fire prevention and fighting, jetties, pipework, storage tanks, static electricity, electrical equipment, road vehicles, tank cars, handling of bitumen products, liquefied petroleum gases, packed products and training of personnel. The code is supplemented by 10 appendices, including a suggested syllabus for a 2-day course on fire prevention and emergency action for managers of oil installations.

  20. Safe Handling of Radioisotopes. First Edition with Revised Appendix I

    International Nuclear Information System (INIS)

    1966-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it was considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. The first edition of such a manual was published in 1958 and represented the first of the 'Safety Series', a series of manuals and codes on health and safety published by the Agency. It was prepared after careful consideration of existing national and international codes of radiation safety by a group of international experts and in consultation with other international bodies. This edition presents the first revision. It incorporates in the Appendices the latest recommendations of the International Commission on Radiological Protection and extracts from the report of the Committee II of the I.C.R.P. on permissible dose for internal radiation. The Health Physics and Medical Addenda to this Manual, published as No. 2 and No. 3 in the Safety Series in 1960, give more complete advice to the user on specialized topics.

  1. Can Control Banding be Useful for the Safe Handling of Nanomaterials? A Systematic Review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Objectives Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” Methods A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control’, ‘hazard’, ‘exposure’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the Methodological Index for Non-Randomized Studies (MINORS). The quality of the evidence was evaluated using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Results A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these

  2. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    International Nuclear Information System (INIS)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  3. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Eastlake, Adrienne, E-mail: aeastlake@cdc.gov [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States); Zumwalde, Ralph [RCS Corporation (United States); Geraci, Charles [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States)

    2016-06-15

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  4. Predictors of low back pain in nursing home workers after implementation of a safe resident handling programme.

    Science.gov (United States)

    Gold, Judith E; Punnett, Laura; Gore, Rebecca J

    2017-06-01

    Healthcare workers have high rates of low back pain (LBP) related to handling patients. A large chain of nursing homes experienced reduced biomechanical load, compensation claims and costs following implementation of a safe resident handling programme (SRHP). The aim of this study was to examine whether LBP similarly declined and whether it was associated with relevant self-reported occupational exposures or personal health factors. Worker surveys were conducted on multiple occasions beginning with the week of first SRHP introduction (baseline). In each survey, the outcome was LBP during the prior 3 months with at least mild severity during the past week. Robust Poisson multivariable regression models were constructed to examine correlates of LBP cross-sectionally at 2 years (F3) and longitudinally at 5-6 years (F5) post-SRHP implementation among workers also in at least one prior survey. LBP prevalence declined minimally between baseline and F3. The prevalence was 37% at F3 and cumulative incidence to F5 was 22%. LBP prevalence at F3 was positively associated with combined physical exposures, psychological job demands and prior back injury, while frequent lift device usage and 'intense' aerobic exercise frequency were protective. At F5, the multivariable model included frequent lift usage at F3 (relative risk (RR) 0.39 (0.18 to 0.84)) and F5 work-family imbalance (RR=1.82 (1.12 to 2.98)). In this observational study, resident lifting device usage predicted reduced LBP in nursing home workers. Other physical and psychosocial demands of nursing home work also contributed, while frequent intense aerobic exercise appeared to reduce LBP risk. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Expanded Occupational Safety and Health Administration 300 log as metric for bariatric patient-handling staff injuries.

    Science.gov (United States)

    Randall, Stephen B; Pories, Walter J; Pearson, Amy; Drake, Daniel J

    2009-01-01

    Mobilization of morbidly obese patients poses significant physical challenges to healthcare providers. The purpose of this study was to examine the staff injuries associated with the patient handling of the obese, to describe a process for identifying injuries associated with their mobilization, and to report on the need for safer bariatric patient handling. We performed our study at a 761-bed, level 1 trauma center affiliated with a U.S. medical school. The hospital's Occupational Safety and Health Administration (OSHA) 300 log was expanded to the "E-OSHA 300 log" to specifically identify injuries the staff attributed to bariatric patient handling. The 2007 E-OSHA 300 log was analyzed to identify and describe the frequency, severity, and nature of bariatric versus nonbariatric patient handling injuries. The analyses revealed that during 2007, although patients with a body mass index of > or =35 kg/m(2) constituted patient population, 29.8% of staff injuries related to patient handling were linked to working with a bariatric patient. Bariatric patient handling accounted for 27.9% of all lost workdays and 37.2% of all restricted workdays associated with patient handling. Registered nurses and nursing assistants accounted for 80% of the injuries related to bariatric patient handling. Turning and repositioning the patient in bed accounted for 31% of the injuries incurred. The E-OSHA 300 log narratives revealed that staff injuries associated with obese and nonobese patient handling were usually performed using biomechanics and not equipment. Manual mobilization of morbidly obese patients increases the risk of caregiver injury. A tracking indicator on the OSHA 300 logs for staff injury linked to a bariatric patient would provide the ability to compare obese and nonobese patient handling injuries. The E-OSHA 300 log provides a method to identify the frequency, severity, and nature of caregiver injury during mobilization of the obese. Understanding the heightened risk of

  6. METHODS FOR THE SAFE STORAGE, HANDLING, AND DISPOSAL OF PYROPHORIC LIQUIDS AND SOLIDS IN THE LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, F.; Kuntamukkula, M.; Alnajjar, M.; Quigley, D.; Freshwater, D.; Bigger, S.

    2010-02-02

    Pyrophoric reagents represent an important class of reactants because they can participate in many different types of reactions. They are very useful in organic synthesis and in industrial applications. The Occupational Safety and Health Administration (OSHA) and the National Fire Protection Association (NFPA) define Pyrophorics as substances that will self-ignite in air at temperatures of 130 F (54.4 C) or less. However, the U.S. Department of Transportation (DOT) uses criteria different from the auto-ignition temperature criterion. The DOT defines a pyrophoric material as a liquid or solid that, even in small quantities and without an external ignition source, can ignite within five minutes after coming in contact with air when tested according to the United Nations Manual of Tests and Criteria. The Environmental Protection Agency has adopted the DOT definition. Regardless of which definition is used, oxidation of the pyrophoric reagents by oxygen or exothermic reactions with moisture in the air (resulting in the generation of a flammable gas such as hydrogen) is so rapid that ignition occurs spontaneously. Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel. Because of this danger, pyrophorics should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior

  7. Patient Involvement in Safe Delivery: A Qualitative Study

    OpenAIRE

    Olfati, Forozun; Asefzadeh, Saeid; Changizi, Nasrin; Keramat, Afsaneh; Yunesian, Masud

    2015-01-01

    Introduction: Patient involvement in safe delivery planning is considered important yet not widely practiced. The present study aimed at identifythe factors that affect patient involvementin safe delivery, as recommended by parturient women. Methods: This study was part of a qualitative research conducted by content analysis method and purposive sampling in 2013. The data were collected through 63 semi-structured interviews in4 hospitalsand analyzed using thematic content analysis. The partic...

  8. Knowledge and Food Handling Practices of Nurses in a Tertiary Health Care Hospital in Nigeria.

    Science.gov (United States)

    Oludare, Aluko Olufemi; Ogundipe, Abiodun; Odunjo, Abimbola; Komolafe, Janet; Olatunji, Ibukun

    2016-01-01

    Food safety in hospitals is important to protect patients whose immunity may be compromised by their illness. The safety of food served to patients is dependent on its handling acquisition of raw food items, to preparation, packaging, and distribution. The study described in this article assessed the knowledge and food handling practices of nurses in the food chain to patients in the hospital wards. The mean age of respondents was 33.7 ± 9.3 years and 180 (56.6%) had worked in the hospital for 1-5 years. While respondents had good knowledge scores overall, only 22 (6.5%) knew the correct temperature for maintaining hot, ready-to-eat food. Also, 332 (97.6%) respondents knew the importance of hand washing before handling food while 279 (84.1%) always wash hands before handling food. The study revealed a decline in performance over time, from knowledge and attitudes to practice in food handling. Therefore, regular training on safe food handling procedures should be mainstreamed into the training curriculum of staff nurses in health care institutions.

  9. Safe Minimum Internal Temperature Chart

    Science.gov (United States)

    ... Internal Temperature Chart Safe steps in food handling, cooking, and storage are essential in preventing foodborne illness. You can't see, smell, or taste harmful bacteria that may cause illness. In every step of food preparation, follow the four guidelines to keep food safe: ...

  10. Guidelines for safe handling of toxins. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, M.

    1995-11-01

    Toxins are highly toxic chemicals which cause illness through all routes of entry into the body. This technical note has been prepared to ensure that preparation, handling, and disposal of toxins does not constitute a greater occupational hazard than is necessary. It includes hazards that may be encountered and the precautions that should be taken against such hazards.

  11. The influence of ergonomic devices on mechanical load during patient handling activities in nursing homes.

    Science.gov (United States)

    Koppelaar, Elin; Knibbe, Hanneke J J; Miedema, Harald S; Burdorf, Alex

    2012-07-01

    Mechanical load during patient handling activities is an important risk factor for low back pain among nursing personnel. The aims of this study were to describe required and actual use of ergonomic devices during patient handling activities and to assess the influence of these ergonomic devices on mechanical load during patient handling activities. For each patient, based on national guidelines, it was recorded which specific ergonomic devices were required during distinct patient handling activities, defined by transferring a patient, providing personal care, repositioning patients in the bed, and putting on and taking off anti-embolism stockings. During real-time observations over ~60 h among 186 nurses on 735 separate patient handling activities in 17 nursing homes, it was established whether ergonomic devices were actually used. Mechanical load was assessed through observations of frequency and duration of a flexed or rotated trunk >30° and frequency of pushing, pulling, lifting or carrying requiring forces 230 N from start to end of each separate patient handling activity. The number of patients and nurses per ward and the ratio of nurses per patient were used as ward characteristics with potential influence on mechanical load. A mixed-effect model for repeated measurements was used to determine the influence of ergonomic devices and ward characteristics on mechanical load. Use of ergonomic devices was required according to national guidelines in 520 of 735 (71%) separate patient handling activities, and actual use was observed in 357 of 520 (69%) patient handling activities. A favourable ratio of nurses per patient was associated with a decreased duration of time spent in awkward back postures during handling anti-embolism stocking (43%), patient transfers (33%), and personal care of patients (24%) and also frequency of manually lifting patients (33%). Use of lifting devices was associated with a lower frequency of forces exerted (64%), adjustable bed and

  12. Materials Handling. Module SH-01. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on materials handling is one of 50 modules concerned with job safety and health. It presents the procedures for safe materials handling. Discussed are manual handling methods (lifting and carrying by hand) and mechanical lifting (lifting by powered trucks, cranes or conveyors). Following the introduction, 15 objectives (each…

  13. Effects of the Smartphone Application "Safe Patients" on Knowledge of Patient Safety Issues Among Surgical Patients.

    Science.gov (United States)

    Cho, Sumi; Lee, Eunjoo

    2017-12-01

    Recently, the patient's role in preventing adverse events has been emphasized. Patients who are more knowledgeable about safety issues are more likely to engage in safety initiatives. Therefore, nurses need to develop techniques and tools that increase patients' knowledge in preventing adverse events. For this reason, an educational smartphone application for patient safety called "Safe Patients" was developed through an iterative process involving a literature review, expert consultations, and pilot testing of the application. To determine the effect of "Safe Patients," it was implemented for patients in surgical units in a tertiary hospital in South Korea. The change in patients' knowledge about patient safety was measured using seven true/false questions developed in this study. A one-group pretest and posttest design was used, and a total of 123 of 190 possible participants were tested. The percentage of correct answers significantly increased from 64.5% to 75.8% (P effectively improve patients' knowledge of safety issues. This will ultimately empower patients to engage in safe practices and prevent adverse events related to surgery.

  14. Patient Involvement in Safe Delivery: A Qualitative Study.

    Science.gov (United States)

    Olfati, Forozun; Asefzadeh, Saeid; Changizi, Nasrin; Keramat, Afsaneh; Yunesian, Masud

    2015-09-28

    Patient involvement in safe delivery planning is considered important yet not widely practiced. The present study aimed at identifythe factors that affect patient involvementin safe delivery, as recommended by parturient women. This study was part of a qualitative research conducted by content analysis method and purposive sampling in 2013.The data were collected through 63 semi-structured interviews in4 hospitalsand analyzed using thematic content analysis. The participants in this research were women before discharge and after delivery. Findings were analyzed using Colaizzi's method. Four categories of factors that could affect patient involvement in safe delivery emerged from our analysis: patient-related (true and false beliefs, literacy, privacy, respect for patient), illness-related (pain, type of delivery, patient safety incidents), health care professional-relatedand task-related factors (behavior, monitoring &training), health care setting-related (financial aspects, facilities). More research is needed to explore the factors affecting the participation of mothers. It is therefore, recommended to: 1) take notice of mother education, their husbands, midwives and specialists; 2) provide pregnant women with insurance coverage from the outset of pregnancy, especially during prenatal period; 3) form a labor pain committee consisting of midwives, obstetricians, and anesthesiologists in order to identify the preferred painless labor methods based on the existing facilities and conditions, 4) carry out research on observing patients' privacy and dignity; 5) pay more attention on the factors affecting cesarean.

  15. Guidelines for safe handling, use and disposal of nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Amoabediny, G H; Rashedi, H [Department of Biotechnology, Faculty of Chemical Engineering, University of Tehran (Iran, Islamic Republic of)], E-mail: amoabedini@ut.ac.ir; Naderi, A [Department of Occupational Health, Faculty of Medical Science, University of Tarbiat Modares (Iran, Islamic Republic of); Malakootikhah, J [Nanotechnology Standardisation Committee, Iran Nanotechnology Initiative, Tehran (Iran, Islamic Republic of); Koohi, M K [Faculty of veterinary medicine, University of Tehran (Iran, Islamic Republic of); Mortazavi, S A [Department of Nanosafety, Research Centre for New Technology in life science Engineering, University of Tehran (Iran, Islamic Republic of); Naderi, M [University of Amirkabir (Iran, Islamic Republic of)

    2009-05-01

    situations, performing administrative means of control constitute other ways of limiaiting the occupational exposure risks. Accordingly, to minimize the risks from know and unknown health, safety and invironment hazards in research and occupational setting of the country, guideline for safe handling, use and disposal of manopractical has provided.

  16. Guidelines for safe handling, use and disposal of nanoparticles

    International Nuclear Information System (INIS)

    Amoabediny, G H; Rashedi, H; Naderi, A; Malakootikhah, J; Koohi, M K; Mortazavi, S A; Naderi, M

    2009-01-01

    situations, performing administrative means of control constitute other ways of limiaiting the occupational exposure risks. Accordingly, to minimize the risks from know and unknown health, safety and invironment hazards in research and occupational setting of the country, guideline for safe handling, use and disposal of manopractical has provided.

  17. Design approach for safe tritium handling in ITER

    International Nuclear Information System (INIS)

    Ohira, Shigeru

    2002-01-01

    Outlines for tritium handling and a fundamental approach for ensuring safety are presented. The amount of tritium stored and processed in the ITER facility will be much larger than that in the existing facilities for fusion research, though the processing methods and the conditions of processing (e.g., concentration, pressure, etc.) will be similar for those used in those facilities. Therefore, considerations to be taken for tritium handling, such as limitations of tritium permeation and leaks, provision of an appropriate ventilation/detritiation system for maintenance, measures to ensure mechanical integrity, etc., can be provided based on the knowledge obtained in the facilities. The Technical Advisory Committee of the Science and Technology Agency established a fundamental approach in 2000, and set out the basic safety principles and approaches as technical requirements of safety design and assessment, which were derived from the safety characteristics of the ITER plant. Sufficient prevention of accidents can be achieved by ensuring and maintaining the structural integrity of the enclosures containing radioactive materials against the loads anticipated during operation, and a low hazard potential of radioactive materials, sufficiently within prescribed limits, can be maintained by the vitiation and clean-up system even if large release is postulated. (author)

  18. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil.

    Science.gov (United States)

    Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa Sobrinho, Paulo de Souza; da Silva, Daniele Ferreira

    2015-06-01

    Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  19. Enclosure for handling high activity materials

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  20. Enclosure for handling high activity materials

    Energy Technology Data Exchange (ETDEWEB)

    Jimeno de Osso, F

    1977-07-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  1. Safe Reentry for False Aneurysm Operations in High-Risk Patients.

    Science.gov (United States)

    Martinelli, Gian Luca; Cotroneo, Attilio; Caimmi, Philippe Primo; Musica, Gabriele; Barillà, David; Stelian, Edmond; Romano, Angelo; Novelli, Eugenio; Renzi, Luca; Diena, Marco

    2017-06-01

    In the absence of a standardized safe surgical reentry strategy for high-risk patients with large or anterior postoperative aortic false aneurysm (PAFA), we aimed to describe an effective and safe approach for such patients. We prospectively analyzed patients treated for PAFA between 2006 and 2015. According to the preoperative computed tomography scan examination, patients were divided into two groups according to the anatomy and extension of PAFA: in group A, high-risk PAFA (diameter ≥3 cm) developed in the anterior mediastinum; in group B, low-risk PAFA (diameter <3 cm) was situated posteriorly. For group A, a safe surgical strategy, including continuous cerebral, visceral, and coronary perfusion was adopted before resternotomy; group B patients underwent conventional surgery. We treated 27 patients (safe reentry, n = 13; standard approach, n = 14). Mean age was 60 years (range, 29 to 80); 17 patients were male. Mean interval between the first operation and the last procedure was 4.3 years. Overall 30-day mortality rate was 7.4% (1 patient in each group). No aorta-related mortality was observed at 1 and 5 years in either group. The Kaplan-Meier overall survival estimates at 1 and 5 years were, respectively, 92.3% ± 7.4% and 73.4% ± 13.4% in group A, and 92.9% ± 6.9% and 72.2% ± 13.9% in group B (log rank test, p = 0.830). Freedom from reoperation for recurrent aortic disease was 100% at 1 year and 88% at 5 years. The safe reentry technique with continuous cerebral, visceral, and coronary perfusion for high-risk patients resulted in early and midterm outcomes similar to those observed for low-risk patients undergoing conventional surgery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Systematic review of patient handling activities starting in lying, sitting and standing positions.

    Science.gov (United States)

    Hignett, Sue

    2003-03-01

    Over the last 20 years a number of methods have been recommended in professional guidelines for moving patients. This review was undertaken as it was recognized that there was a need for clinical work involving handling patients (systems of work and equipment) to be based on scientific evidence. The aim of this paper is to report the methodology, search strategy and results relating to work involving the care, treatment and transfer of patients starting in lying, sitting and standing positions. An unusual philosophical stance has been taken by appraising studies within a study type rather than comparatively. This facilitated the inclusion of a wide range of study designs (quantitative and qualitative). A string search was run on eight databases and supplemented by other search strategies. A published checklist was selected and inter-rater reliability established before the main review commenced. A systematic process for inclusion, exclusion, appraisal, extraction and synthesis was undertaken. Thirty-two studies were included: nine for activities with the patient starting in a lying position and 23 for the sitting position. No studies were found with respect to patient handling activities starting in a standing position. These data were synthesized into evidence statements. The evidence statements support the use of hoists (for nonweight bearing patients), standaids, sliding sheets (double thickness rollers), lateral transfer boards, walking belts and adjustable height beds and baths. It is suggested that these items should constitute a minimum equipment list for any clinical environment where patient handling takes place on a regular basis. The lack of research relating to patient handling in standing is of particular concern and it is recommended that this area should be a high research priority to address concerns about patient handling in rehabilitation activities.

  3. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil

    Directory of Open Access Journals (Sweden)

    Raquel Oliveira Medrado Pinto

    2015-06-01

    Full Text Available Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05. Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  4. Enclosure for handling high activity materials abstract

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.; Dominguez Rodriguez, G.; Cruz Castillo, F. de la; Rodriguez Esteban, A.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With that purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. A description is given of those aspects that may be of interest to people working in this field. (author) [es

  5. Safe use of nanomaterials

    CERN Multimedia

    2013-01-01

    The use of nanomaterials  is on the increase worldwide, including at CERN. The HSE Unit has established a safety guideline to inform you of the main requirements for the safe handling and disposal of nanomaterials at CERN.   A risk assessment tool has also been developed which guides the user through the process of evaluating the risk for his or her activity. Based on the calculated risk level, the tool provides a list of recommended control measures.   We would therefore like to draw your attention to: Safety Guideline C-0-0-5 - Safe handling and disposal of nanomaterials; and Safety Form C-0-0-2 - Nanomaterial Risk Assessment   You can consult all of CERN’s safety rules and guidelines here. Please contact the HSE Unit for any questions you may have.   The HSE Unit

  6. Safe Handover : Safe Patients - The Electronic Handover System.

    Science.gov (United States)

    Till, Alex; Sall, Hanish; Wilkinson, Jonathan

    2014-01-01

    Failure of effective handover is a major preventable cause of patient harm. We aimed to promote accurate recording of high-quality clinical information using an Electronic Handover System (EHS) that would contribute to a sustainable improvement in effective patient care and safety. Within our hospital the human factors associated with poor communication were compromising patient care and unnecessarily increasing the workload of staff due to the poor quality of handovers. Only half of handovers were understood by the doctors expected to complete them, and more than half of our medical staff felt it posed a risk to patient safety. We created a standardised proforma for handovers that contained specific sub-headings, re-classified patient risk assessments, and aided escalation of care by adding prompts for verbal handover. Sources of miscommunication were removed, accountability for handovers provided, and tasks were re-organised to reduce the workload of staff. Long-term, three-month data showed that each sub-heading achieved at least 80% compliance (an average improvement of approximately 40% for the overall quality of handovers). This translated into 91% of handovers being subjectively clear to junior doctors. 87% of medical staff felt we had reduced a risk to patient safety and 80% felt it increased continuity of care. Without guidance, doctors omit key information required for effective handover. All organisations should consider implementing an electronic handover system as a viable, sustainable and safe solution to handover of care that allows patient safety to remain at the heart of the NHS.

  7. Compilation of Requirements for Safe Handling of Fluorine and Fluorine-Containing Products of Uranium Hexafluoride Conversion

    Energy Technology Data Exchange (ETDEWEB)

    Ferrada, J.J.

    2000-04-03

    Public Law (PL) 105-204 requires the U.S. Department of Energy to develop a plan for inclusion in the fiscal year 2000 budget for conversion of the Department's stockpile of depleted uranium hexafluoride (DUF{sub 6}) to a more stable form over an extended period. The conversion process into a more stable form will produce fluorine compounds (e.g., elemental fluorine or hydrofluoric acid) that need to be handled safely. This document compiles the requirements necessary to handle these materials within health and safety standards, which may apply in order to ensure protection of the environment and the safety and health of workers and the public. Fluorine is a pale-yellow gas with a pungent, irritating odor. It is the most reactive nonmetal and will react vigorously with most oxidizable substances at room temperature, frequently with ignition. Fluorine is a severe irritant of the eyes, mucous membranes, skin, and lungs. In humans, the inhalation of high concentrations causes laryngeal spasm and broncospasms, followed by the delayed onset of pulmonary edema. At sublethal levels, severe local irritation and laryngeal spasm will preclude voluntary exposure to high concentrations, unless the individual is trapped or incapacitated. A blast of fluorine gas on the shaved skin of a rabbit causes a second degree burn. Lower concentrations cause severe burns of insidious onset, resulting in ulceration, similar to the effects produced by hydrogen fluoride. Hydrofluoric acid is a colorless, fuming liquid or gas with a pungent odor. It is soluble in water with release of heat. Ingestion of an estimated 1.5 grams produced sudden death without gross pathological damage. Repeated ingestion of small amounts resulted in moderately advanced hardening of the bones. Contact of skin with anhydrous liquid produces severe burns. Inhalation of AHA or aqueous hydrofluoric acid mist or vapors can cause severe respiratory tract irritation that may be fatal. Based on the extreme chemical

  8. Custom sectional impression trays with interlocking type handle for microstomia patients

    Directory of Open Access Journals (Sweden)

    Fernandes Aquaviva

    2009-01-01

    Full Text Available Making impressions in microstomia patients is often cumbersome. A modification of standard impression procedure is often necessary while treating such patients. This article describes the fabrication of a custom sectional impression tray with interlocking type of a handle for definitive impression procedures in a microstomia patient.

  9. Equipment for the handling of thorium materials

    International Nuclear Information System (INIS)

    Heisler, S.W. Jr.; Mihalovich, G.S.

    1988-01-01

    The Feed Materials Production Center (FMPC) is the United States Department of Energy's storage facility for thorium. FMPC thorium handling and overpacking projects ensure the continued safe handling and storage of the thorium inventory until final disposition of the materials is determined and implemented. The handling and overpacking of the thorium materials requires the design of a system that utilizes remote handling and overpacking equipment not currently utilized at the FMPC in the handling of uranium materials. The use of remote equipment significantly reduces radiation exposure to personnel during the handling and overpacking efforts. The design system combines existing technologies from the nuclear industry, the materials processing and handling industry and the mining industry. The designed system consists of a modified fork lift truck for the transport of thorium containers, automated equipment for material identification and inventory control, and remote handling and overpacking equipment for material identification and inventory control, and remote handling and overpacking equipment for repackaging of the thorium materials

  10. Uranium hexafluoride: A manual of good handling practices. Revision 7

    International Nuclear Information System (INIS)

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF 6 handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  11. Evaluation of ergonomic risk factors in manual patient handling ...

    African Journals Online (AJOL)

    WMSDs among nurses in West Bengal, India, evaluates the postural stresses and analyses manual patient handling risks. Responses were collected from 220 nurses by validated questionnaires. The activity and posture analyses were done through photography and by Rapid Entire Body Assessment (REBA). Results ...

  12. Advising Your Elderly Patients Concerning Safe Exercising

    OpenAIRE

    Myers, Anita

    1987-01-01

    With the emergence of physical activity programs geared specifically to senior citizens, family physicians will increasingly be called on to provide advice or approval concerning their patients' suitability for participation. In addition, family physicians have been identified as having a key role to play in the promotion of exercise for sedentary older adults. To assist the family practitioner in advising elderly patients concerning safe exercise patterns, this article discusses the document...

  13. Uranium hexafluoride: A manual of good handling practices

    International Nuclear Information System (INIS)

    1991-10-01

    For many years, the US Department of Energy (DOE) and its predecessor agencies have shared with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The information contained in this manual updates information contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described and tabulated. The nuclear industry is responsible for furnishing its own shipping cylinders and suitable protective overpacks. A substantial effort has been made by the industry to standardize UF 6 cylinders, samples, and overpacks. The quality of feed materials is important to the safe and efficient operation of the enriching facilities, and the UF 6 product purity from the enriching facilities is equally important to the fuel fabricator, the utilities, the operators of research reactors, and other users. The requirements have been the impetus for an aggressive effort by DOE and its contractors to develop accurate techniques for sampling and for chemical and isotopic analysis. A quality control program is maintained within the DOE enriching facilities to ensure that the proper degree of accuracy and precision are obtained for all the required measurements. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated in DOE facilities during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  14. Safe Handover : Safe Patients – The Electronic Handover System

    Science.gov (United States)

    Till, Alex; Sall, Hanish; Wilkinson, Jonathan

    2014-01-01

    Failure of effective handover is a major preventable cause of patient harm. We aimed to promote accurate recording of high-quality clinical information using an Electronic Handover System (EHS) that would contribute to a sustainable improvement in effective patient care and safety. Within our hospital the human factors associated with poor communication were compromising patient care and unnecessarily increasing the workload of staff due to the poor quality of handovers. Only half of handovers were understood by the doctors expected to complete them, and more than half of our medical staff felt it posed a risk to patient safety. We created a standardised proforma for handovers that contained specific sub-headings, re-classified patient risk assessments, and aided escalation of care by adding prompts for verbal handover. Sources of miscommunication were removed, accountability for handovers provided, and tasks were re-organised to reduce the workload of staff. Long-term, three-month data showed that each sub-heading achieved at least 80% compliance (an average improvement of approximately 40% for the overall quality of handovers). This translated into 91% of handovers being subjectively clear to junior doctors. 87% of medical staff felt we had reduced a risk to patient safety and 80% felt it increased continuity of care. Without guidance, doctors omit key information required for effective handover. All organisations should consider implementing an electronic handover system as a viable, sustainable and safe solution to handover of care that allows patient safety to remain at the heart of the NHS. PMID:26734244

  15. Fuel handling machine and auxiliary systems for a fuel handling cell

    International Nuclear Information System (INIS)

    Suikki, M.

    2013-10-01

    repair measures. For this reason, the fuel handling machine is designed in such a way that a single fault does not bring about such a situation. The fuel handling machine operation was subjected to a risk analysis. The fault conditions offer a possibility of safe situation defusing measures and the fuel handling cell tightness guarantees that no radioactive releases escape outside the facility. As the analysis was being conducted, improvement proposals were discovered regarding certain functions of the fuel handling cell. The total cost estimate, without value added tax, for manufacturing the system amounted to 3 980 000 euros. (orig.)

  16. Fuel handling machine and auxiliary systems for a fuel handling cell

    Energy Technology Data Exchange (ETDEWEB)

    Suikki, M. [Optimik Oy, Turku (Finland)

    2013-10-15

    repair measures. For this reason, the fuel handling machine is designed in such a way that a single fault does not bring about such a situation. The fuel handling machine operation was subjected to a risk analysis. The fault conditions offer a possibility of safe situation defusing measures and the fuel handling cell tightness guarantees that no radioactive releases escape outside the facility. As the analysis was being conducted, improvement proposals were discovered regarding certain functions of the fuel handling cell. The total cost estimate, without value added tax, for manufacturing the system amounted to 3 980 000 euros. (orig.)

  17. Uranium hexafluoride: A manual of good handling practices. Revision 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

  18. Online Learning of Safe Patient Transfers in Occupational Therapy Education

    Directory of Open Access Journals (Sweden)

    Cynthia L. Hayden D. H. Ed., OTR/L, CHT

    2013-02-01

    Full Text Available Online higher education is steadily increasing. For programs in allied health to be offered effectively in an elearning format, clinical psychomotor skills need to be addressed. The aim of this research was to design, implement, and evaluate an online safe patient transfers module for occupational therapy assistant (OTAstudents. The efficacy of teaching safe patient transfers in an e-learning environment was appraised using both quantitative and qualitative analysis. The applied research project was completed at a Tennessee community college. A convenience sample of eighteen students participated in the pilot study. Twenty-five studentsparticipated in the subsequent study. The instructional design of the course was based on Mager’s CriterionReferenced Instruction model. Streaming video was used as the delivery method for course material. A pretest/posttest evaluated the students’ cognitive knowledge of safe patient transfers. A behavioral transferscompetency checklist was used to rate videotapes of students’ performance of assisted stand pivot and dependent sliding board transfers. Research findings indicated students were able to learn this psychomotor clinical skill online with beginning proficiency. A paired t-test showed marked improvement of cognitive knowledge. A student learning survey revealed the majority of students preferred at least one hands-on classroom session where instructor feedback and interaction with classmates confirmed safe and effectiveclinical technique.

  19. Safety handling of beryllium for fusion technology R and D

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Okamoto, Makoto; Terai, Takayuki; Odawara, Osamu; Ashibe, Kusuo; Ohara, Atsushi.

    1992-07-01

    Feasibility of beryllium use as a blanket neutron multiplier, first wall and plasma facing material has been studied for the D-T burning experiment reactors such as ITER. Various experimental work of beryllium and its compounds will be performed under the conditions of high temperature and high energy particle exposure simulating fusion reactor conditions. Beryllium is known as a hazardous substance and its handling has been carefully controlled by various health and safe guidances and/or regulations in many countries. Japanese regulations for hazardous substance provide various guidelines on beryllium for the protection of industrial workers and environment. This report was prepared for the safe handling of beryllium in a laboratory scale experiments for fusion technology R and D such as blanket development. Major items in this report are; (1) Brief review of guidances and regulations in USA, UK and Japan. (2) Safe handling and administration manuals at beryllium facilities in INEL, LANL and JET. (3) Conceptual design study of beryllium handling facility for small to mid-scale blanket R and D. (4) Data on beryllium toxicity, example of clinical diagnosis of beryllium disease, and environmental occurence of beryllium. (5) Personnel protection tools of Japanese Industrial Standard for hazardous substance. (author) 61 refs

  20. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  1. Safe Handling of Cytotoxic Drugs and Risks of Occupational Exposure to Nursing Staffs

    Directory of Open Access Journals (Sweden)

    Somayeh Hanafi

    2016-05-01

    Full Text Available Background: Inherent toxicity of cytotoxic drugs is the basis for their potential adverse risks from occupational exposure to the nursing staff. In Iran, chemotherapy regimens are prescribed and administered according to the world updated protocols. But little is done regarding the protective standards in this field.Methods: An observational cross-sectional survey was conducted among nurses who work in three tertiary care teaching hospitals in Tehran, Iran in 2012. All participants worked in one of the hospital wards handling cytotoxic drugs (preparation and administration. A questionnaire was used for interviewing all subjects, and observing them preparing and administering the drugs. We examined all adverse effects associated with handling of antineoplastic drugs.Results: Totally 270 adverse reactions were reported. The most frequently reported adverse effects included headache and vertigo (40 cases, hair loss (36 cases, skin rashes and itching (31 cases, and burning sensation in eyes (31 cases. In all hospital wards, the standards were met in not more than 50% of the items.Conclusion: Monitoring the personnel who are directly involved in handling of cytotoxic drugs is of great importance. Furthermore, educating the personnel in the field of standards of cytotoxic drugs handling could increase the nursing staff’s knowledge regarding these drugs’ adverse reactions.

  2. Hygienic food handling behaviours. An application of the Theory of Planned Behaviour.

    Science.gov (United States)

    Mullan, Barbara A; Wong, Cara L

    2009-06-01

    It is estimated that 5.4 million Australians get sick annually from eating contaminated food and that up to 20% of this illness results from food handling behaviour. A study was undertaken to investigate the efficacy of the Theory of Planned Behaviour (TPB) including past behaviour in predicting safe food handling intention and behaviour. One hundred and nine participants completed questionnaires regarding their attitudes, perceived behavioural control (PBC), subjective norm, intentions and past behaviour. Behaviour was measured 4 weeks later. The TPB predicted a high proportion of variance in both intentions and behaviour, and past behaviour/habit was found to be the strongest predictor of behaviour. The results of the present study suggest interventions aimed at increasing safe food handling intentions should focus on the impact of normative influences and perceptions of control over their food handling environment; whereas interventions to change actual behaviour should attempt to increase hygienic food handling as a habitual behaviour.

  3. Safe handling and monitoring of tritium in research on nuclear fusion

    International Nuclear Information System (INIS)

    Yoshida, Yoshikazu; Naruse, Yuji

    1978-01-01

    An actual condition of technique of safety handling and monitoring of tritium in the laboratory which treated a great quantity of tritium in relation to nuclear fusion, was described. With respect to the technique of safety handling of tritium, an actual condition of the technique in the U.S.A. which had wide experience in treating a great quantity of 3 H was mainly introduced, and it was helpful to a safety measure and a reduction of tritium effluence. Glovebox, hood, and other component machinery and tools for treating 3 H were also introduced briefly. As a monitoring technique, monitoring of indoor air and air exhaust by ionization chamber-type monitor for continuous monitoring of a great quantity of gaseous tritium was mentioned. Next, monitoring of a room, the surfaces of equipments, and draining, internal exposure of the individual, and monitoring of the environment were introduced. (Kanao, N.)

  4. Safe medication management in specialized home healthcare - an observational study.

    Science.gov (United States)

    Lindblad, Marléne; Flink, Maria; Ekstedt, Mirjam

    2017-08-24

    Medication management is a complex, error-prone process. The aim of this study was to explore what constitutes the complexity of the medication management process (MMP) in specialized home healthcare and how healthcare professionals handle this complexity. The study is theoretically based in resilience engineering. Data were collected during the MMP at three specialized home healthcare units in Sweden using two strategies: observation of workplaces and shadowing RNs in everyday work, including interviews. Transcribed material was analysed using grounded theory. The MMP in home healthcare was dynamic and complex with unclear boundaries of responsibilities, inadequate information systems and fluctuating work conditions. Healthcare professionals adapted their everyday clinical work by sharing responsibility and simultaneously being authoritative and preserving patients' active participation, autonomy and integrity. To promote a safe MMP, healthcare professionals constantly re-prioritized goals, handled gaps in communication and information transmission at a distance by creating new bridging solutions. Trade-offs and workarounds were necessary elements, but also posed a threat to patient safety, as these interim solutions were not systematically evaluated or devised learning strategies. To manage a safe medication process in home healthcare, healthcare professionals need to adapt to fluctuating conditions and create bridging strategies through multiple parallel activities distributed over time, space and actors. The healthcare professionals' strategies could be integrated in continuous learning, while preserving boundaries of safety, instead of being more or less interim solutions. Patients' and family caregivers' as active partners in the MMP may be an underestimated resource for a resilient home healthcare.

  5. Manual on safe production, transport, handling and storage of uranium hexafluoride

    International Nuclear Information System (INIS)

    1994-11-01

    This document includes a description of the physical, chemical and radiological properties of UF 6 and related products, including information concerning their production, handling, storage and transportation and the management of the wastes which result. All the operations of UF 6 management are considered form a safety point of view. The IAEA organized a series of meetings to consider the hazards of UF 6 transport since considerable quantities of depleted, natural and enriched UF 6 are transported between nuclear fuel sites. Storage of depleted UF 6 is another important issue. Factors affecting long term storage are presented, especially site choice and cylinder corrosion. Other topics such as waste management, quality assurance and emergency preparedness which contribute to the overall safety of UF 6 handling, are included. The intention of this document is to provide analysis of the safety implications of all stages of UF 6 operations and to draw attention to specific features and properties of importance. 38 refs, figs, tabs

  6. Handling final storage of unreprocessed spent nuclear fuel

    International Nuclear Information System (INIS)

    1978-01-01

    The present second report from KBS describes how the safe final storage of spent unreprocessed nuclear fuel can be implemented. According to the Swedish Stipulation Law, the owner must specify in which form the waste is to be stored, how final storage is to be effected, how the waste is to be transported and all other aspects of fuel handling and storage which must be taken into consideration in judging whether the proposed final storage method can be considered to be absolutely safe and feasible. Thus, the description must go beyond general plans and sketches. The description is therefore relatively detailed, even concerning those parts which are less essential for evaluating the safety of the waste storage method. For those parts of the handling chain which are the same for both alternatives of the Stipulation Law, the reader is referred in some cases to the first report. Both of the alternatives of the Stipulation Law may be used in the future. Handling equipment and facilities for the two storage methods are so designed that a combination in the desired proportions is practically feasible. In this first part of the report are presented: premises and data, a description of the various steps of the handling procedure, a summary of dispersal processes and a safety analysis. (author)

  7. Uranium hexafluoride: Safe handling, processing, and transporting: Conference proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Strunk, W.D.; Thornton, S.G. (eds.)

    1988-01-01

    This conference seeks to provide a forum for the exchange of information and ideas of the safety aspects and technical issue related to the handling of uranium hexafluoride. By allowing operators, engineers, scientists, managers, educators, and others to meet and share experiences of mutual concern, the conference is also intended to provide the participants with a more complete knowledge of technical and operational issues. The topics for the papers in the proceedings are widely varied and include the results of chemical, metallurgical, mechanical, thermal, and analytical investigations, as well as the developed philosophies of operational, managerial, and regulatory guidelines. Papers have been entered individually into EDB and ERA. (LTN)

  8. Uranium hexafluoride: Safe handling, processing, and transporting: Conference proceedings

    International Nuclear Information System (INIS)

    Strunk, W.D.; Thornton, S.G.

    1988-01-01

    This conference seeks to provide a forum for the exchange of information and ideas of the safety aspects and technical issue related to the handling of uranium hexafluoride. By allowing operators, engineers, scientists, managers, educators, and others to meet and share experiences of mutual concern, the conference is also intended to provide the participants with a more complete knowledge of technical and operational issues. The topics for the papers in the proceedings are widely varied and include the results of chemical, metallurgical, mechanical, thermal, and analytical investigations, as well as the developed philosophies of operational, managerial, and regulatory guidelines. Papers have been entered individually into EDB and ERA

  9. Safety requirements and feedback of commonly used material handling equipment

    International Nuclear Information System (INIS)

    Pathak, M.K.

    2009-01-01

    Different types of cranes, hoists, chain pulley blocks are the most commonly used material handling equipment in industry along with attachments like chains, wire rope slings, d-shackles, etc. These equipment are used at work for transferring loads from one place to another and attachments are used for anchoring, fixing or supporting the load. Selection of the correct equipment, identification of the equipment planning of material handling operation, examination/testing of the equipment, education and training of the persons engaged in operation of the material handling equipment can reduce the risks to safety of people in workplace. Different safety systems like boom angle indicator, overload tripping device, limit switches, etc. should be available in the cranes for their safe use. Safety requirement for safe operation of material handling equipment with emphasis on different cranes and attachments particularly wire rope slings and chain slings have been brought out in this paper. An attempt has also been made to bring out common nature of deficiencies observed during regulatory inspection carried out by AERB. (author)

  10. Laboratory biosafety for handling emerging viruses

    Directory of Open Access Journals (Sweden)

    I. Made Artika

    2017-05-01

    Full Text Available Emerging viruses are viruses whose occurrence has risen within the past twenty years, or whose presence is likely to increase in the near future. Diseases caused by emerging viruses are a major threat to global public health. In spite of greater awareness of safety and containment procedures, the handling of pathogenic viruses remains a likely source of infection, and mortality, among laboratory workers. There is a steady increase in both the number of laboratories and scientist handling emerging viruses for diagnostics and research. The potential for harm associated to work with these infectious agents can be minimized through the application of sound biosafety concepts and practices. The main factors to the prevention of laboratory-acquired infection are well-trained personnel who are knowledgable and biohazard aware, who are perceptive of the various ways of transmission, and who are professional in safe laboratory practice management. In addition, we should emphasize that appropriate facilities, practices and procedures are to be used by the laboratory workers for the handling of emerging viruses in a safe and secure manner. This review is aimed at providing researchers and laboratory personnel with basic biosafety principles to protect themselves from exposure to emerging viruses while working in the laboratory. This paper focuses on what emerging viruses are, why emerging viruses can cause laboratory-acquired infection, how to assess the risk of working with emerging viruses, and how laboratory-acquired infection can be prevented. Control measures used in the laboratory designed as such that they protect workers from emerging viruses and safeguard the public through the safe disposal of infectious wastes are also addressed.

  11. Fuel handling at Cernavoda 1 N.P.S. - commissioning and training philosophy

    Energy Technology Data Exchange (ETDEWEB)

    Standen, G W [AECL-Ansaldo Consortium, Cernavoda (Romania); Tiron, C; Marinescu, S [Regia Nationala de Electricitate (RENEL), Cernavoda (Romania); [Filiala Centrala Nuclearo Electrica (FCNE), Cernavoda (Romania)

    1997-12-31

    Efficient operation of a Candu nuclear power plant depends greatly on the reliable and safe operation of the fuel handling system. Successful commissioning of the system is obviously a key aspect of the reliability of the system and this coupled with a rigorous training programme for the fuel handling staff will ensure the system`s safe operation. This paper describes the philosophy used at Cernavoda 1 N.P.S. for the commissioning of the fuel handling systems and for the training of staff for operation and maintenance of these systems. The paper also reviews the commissioning programme, describing the milestones achieved and discussing some of the more interesting technical aspects which includes some unique Romanian input. In conclusion the paper looks at the organization of the mature fuel handling department from the operations, maintenance and technical support points of view and the long term plans for the future. (author). 1 fig.

  12. Fuel handling at Cernavoda 1 N.P.S. - commissioning and training philosophy

    International Nuclear Information System (INIS)

    Standen, G.W.; Tiron, C.; Marinescu, S.

    1996-01-01

    Efficient operation of a Candu nuclear power plant depends greatly on the reliable and safe operation of the fuel handling system. Successful commissioning of the system is obviously a key aspect of the reliability of the system and this coupled with a rigorous training programme for the fuel handling staff will ensure the system's safe operation. This paper describes the philosophy used at Cernavoda 1 N.P.S. for the commissioning of the fuel handling systems and for the training of staff for operation and maintenance of these systems. The paper also reviews the commissioning programme, describing the milestones achieved and discussing some of the more interesting technical aspects which includes some unique Romanian input. In conclusion the paper looks at the organization of the mature fuel handling department from the operations, maintenance and technical support points of view and the long term plans for the future. (author). 1 fig

  13. Manual on safe production, transport, handling and storage of uranium hexafluoride

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    This document includes a description of the physical, chemical and radiological properties of UF{sub 6} and related products, including information concerning their production, handling, storage and transportation and the management of the wastes which result. All the operations of UF{sub 6} management are considered form a safety point of view. The IAEA organized a series of meetings to consider the hazards of UF{sub 6} transport since considerable quantities of depleted, natural and enriched UF{sub 6} are transported between nuclear fuel sites. Storage of depleted UF{sub 6} is another important issue. Factors affecting long term storage are presented, especially site choice and cylinder corrosion. Other topics such as waste management, quality assurance and emergency preparedness which contribute to the overall safety of UF{sub 6} handling, are included. The intention of this document is to provide analysis of the safety implications of all stages of UF{sub 6} operations and to draw attention to specific features and properties of importance. 38 refs, figs, tabs.

  14. Safe actinide disposition in molten salt reactors

    International Nuclear Information System (INIS)

    Gat, U.

    1997-01-01

    Safe molten salt reactors (MSR) can readily accommodate the burning of all fissile actinides. Only minor compromises associated with plutonium are required. The MSRs can dispose safely of actinides and long lived isotopes to result in safer and simpler waste. Disposing of actinides in MSRs does increase the source term of a safety optimized MSR. It is concluded that the burning and transmutation of actinides in MSRs can be done in a safe manner. Development is needed for the processing to handle and separate the actinides. Calculations are needed to establish the neutron economy and the fuel management. 9 refs

  15. Development and perceived effects of an educational programme on quality and safety in medication handling in residential facilities.

    Science.gov (United States)

    Mygind, Anna; El-Souri, Mira; Rossing, Charlotte; Thomsen, Linda Aagaard

    2018-04-01

    To develop and test an educational programme on quality and safety in medication handling for staff in residential facilities for the disabled. The continuing pharmacy education instructional design model was used to develop the programme with 22 learning objectives on disease and medicines, quality and safety, communication and coordination. The programme was a flexible, modular seven + two days' course addressing quality and safety in medication handling, disease and medicines, and medication supervision and reconciliation. The programme was tested in five Danish municipalities. Municipalities were selected based on their application for participation; each independently selected a facility for residents with mental and intellectual disabilities, and a facility for residents with severe mental illnesses. Perceived effects were measured based on a questionnaire completed by participants before and after the programme. Effects on motivation and confidence as well as perceived effects on knowledge, skills and competences related to medication handling, patient empowerment, communication, role clarification and safety culture were analysed conducting bivariate, stratified analyses and test for independence. Of the 114 participants completing the programme, 75 participants returned both questionnaires (response rate = 66%). Motivation and confidence regarding quality and safety in medication handling significantly improved, as did perceived knowledge, skills and competences on 20 learning objectives on role clarification, safety culture, medication handling, patient empowerment and communication. The programme improved staffs' motivation and confidence and their perceived ability to handle residents' medication safely through improved role clarification, safety culture, medication handling and patient empowerment and communication skills. © 2017 Royal Pharmaceutical Society.

  16. Calculations on safe storage and transportation of radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Hathout, A M; El-Messiry, A M; Amin, E [National Center for Nuclear Safety and Radiation Control and AEA, Cairo (Egypt)

    1997-12-31

    In this work the safe storage and transportation of fresh fuel as a radioactive material studied. Egypt planned ET RR 2 reactor which is of relatively high power and would require adequate handling and transportation. Therefore, the present work is initiated to develop a procedure for safe handling and transportation of radioactive materials. The possibility of reducing the magnitude of radiation transmitted on the exterior of the packages is investigated. Neutron absorbers are used to decrease the neutron flux. Criticality calculations are carried out to ensure the achievement of subcriticality so that the inherent safety can be verified. The discrete ordinate transport code ANISN was used. The results show good agreement with other techniques. 2 figs., 2 tabs.

  17. Regulation and practice of workers' protection from chemical exposures during container handling

    DEFF Research Database (Denmark)

    Nørgaard Fløe Pedersen, Randi; Jepsen, Jørgen Riis; Ádám, Balázs

    2014-01-01

    instructions relate to container handling, the provided information is not sufficiently detailed to conduct safe practice in many aspects. In accordance with the scientific literature, the interviewees estimate that there is a high frequency (5 to 50%) of containers with hazardous chemical exposure......Background: Fumigation of freight containers to prevent spread of pests and off-gassing of freight are sources of volatile chemicals that may constitute significant health risks when released. The aim of the study was to investigate the regulation and practice of container handling in Denmark...... with focus on preventive measures to reduce risk of chemical exposure. Methods: A comprehensive systematic search of scientific literature, legislation and recommendations related to safe work with transport containers from international and Danish regulatory bodies was performed. The practice of handling...

  18. Characteristic values of the lumbar load of manual patient handling for the application in workers' compensation procedures.

    Science.gov (United States)

    Jordan, Claus; Luttmann, Alwin; Theilmeier, Andreas; Kuhn, Stefan; Wortmann, Norbert; Jäger, Matthias

    2011-05-26

    The human spine is often exposed to mechanical load in vocational activities especially in combination with lifting, carrying and positioning of heavy objects. This also applies in particular to nursing activities with manual patient handling. In the present study a detailed investigation on the load of the lumbar spine during manual patient handling was performed. For a total of 13 presumably endangering activities with transferring a patient, the body movements performed by healthcare workers were recorded and the exerted action forces were determined with regard to magnitude, direction and lateral distribution in the time course with a "measuring bed", a "measuring chair" and a "measuring floor". By the application of biomechanical model calculations the load on the lowest intervertebral disc of the lumbar spine (L5-S1) was determined considering the posture and action force data for every manual patient handling. The results of the investigations reveal the occurrence of high lumbar load during manual patient handling activities, especially in those cases, where awkward postures of the healthcare worker are combined with high action forces caused by the patient's mass. These findings were compared to suitable issues of corresponding investigations provided in the literature. Furthermore measurement-based characteristic values of lumbar load were derived for the use in statement procedures concerning the disease no. 2108 of the German list of occupational diseases. To protect healthcare workers from mechanical overload and the risk of developing a disc-related disease, prevention measures should be compiled. Such measures could include the application of "back-fairer" nursing techniques and the use of "technical" and" small aids" to reduce the lumbar load during manual patient handling. Further studies, concerning these aspects, are necessary.

  19. Characteristic values of the lumbar load of manual patient handling for the application in workers' compensation procedures

    Directory of Open Access Journals (Sweden)

    Wortmann Norbert

    2011-05-01

    Full Text Available Abstract Background The human spine is often exposed to mechanical load in vocational activities especially in combination with lifting, carrying and positioning of heavy objects. This also applies in particular to nursing activities with manual patient handling. In the present study a detailed investigation on the load of the lumbar spine during manual patient handling was performed. Methods For a total of 13 presumably endangering activities with transferring a patient, the body movements performed by healthcare workers were recorded and the exerted action forces were determined with regard to magnitude, direction and lateral distribution in the time course with a "measuring bed", a "measuring chair" and a "measuring floor". By the application of biomechanical model calculations the load on the lowest intervertebral disc of the lumbar spine (L5-S1 was determined considering the posture and action force data for every manual patient handling. Results The results of the investigations reveal the occurrence of high lumbar load during manual patient handling activities, especially in those cases, where awkward postures of the healthcare worker are combined with high action forces caused by the patient's mass. These findings were compared to suitable issues of corresponding investigations provided in the literature. Furthermore measurement-based characteristic values of lumbar load were derived for the use in statement procedures concerning the disease no. 2108 of the German list of occupational diseases. Conclusions To protect healthcare workers from mechanical overload and the risk of developing a disc-related disease, prevention measures should be compiled. Such measures could include the application of "back-fairer" nursing techniques and the use of "technical" and" small aids" to reduce the lumbar load during manual patient handling. Further studies, concerning these aspects, are necessary.

  20. Fasting ramadan in kidney transplant patients is safe

    Directory of Open Access Journals (Sweden)

    Boobes Yousef

    2009-01-01

    Full Text Available Muslims with renal transplant often ask their doctors whether fasting Ramadan is safe. Scanty studies have addressed this question. This prospective study was undertaken to identify any clinical or biological changes with Muslim fasting. 22 kidney transplant patients with stable kidney functions, who were transplanted for more than one year, and voluntarily chose to fast during Ramadan in 1425 H (October-November 2004, were studied. Total of 22 subjects (10 men and 12 women with a mean age of 47 ± 11.6 years were studied. Full clinical and biological assessment was done before during and after the month of Ramadan fasting. Medications were taken in two divided doses at sunset (time of breaking the fast and pre dawn (before the fast. None of the patients experienced any undue fatigue, or symptoms. Body weight, blood pressure, kidney function tests, blood sugar, lipid profile, and cyclosporine levels remained stable. In conclusion it is safe for renal transplant recipients of more than one year and having stable graft function to fast during the month of Ramadan; however caution is advised for moderate to severe impaired renal function.

  1. Abnormal MRI in a patient with 'headache with neurological deficits and CSF lymphocytosis (HaNDL)'.

    Science.gov (United States)

    Yilmaz, A; Kaleagasi, H; Dogu, O; Kara, E; Ozge, A

    2010-05-01

    A 27-year-old woman was admitted to the Emergency Department with right upper-extremity numbness and mild weakness followed by a bifrontal throbbing headache for 30 min, which was similar to a headache lasting for 12 h that had occurred 3 days ago. Laboratory tests were unremarkable except for cerebrospinal fluid (CSF) lymphocytic pleocytosis. On the following day, a headache episode with left hemiparesis and hemihypoaesthesia, left hemifield visio-spatial inattention, anosagnosia and confusion recurred. The headache was diagnosed as headache and neurological deficits with cerebrospinal fluid lymphocytosis (HaNDL) syndrome according to the criteria of the second edition of the International Classification of Headache Disorders. Simultaneously performed magnetic resonance imaging (MRI) revealed swelling of the grey matter, CSF enhancement in the sulci of the right temporal and occipital regions and hypoperfusion of the same brain regions. During the following 10 days two more similar episodes recurred and during the ensuing 12 months the patient remained headache free. Neuroimaging findings of the HaNDL syndrome are always thought as virtually normal. MRI abnormalities in our patient have not been reported in HaNDL syndrome previously, although they have been reported in hemiplegic migraine patients before. The findings in our case suggest that hemiplegic migraine and HaNDL syndrome may share a common pathophysiological pathway resulting in similar imaging findings and neurological symptoms.

  2. Procedures for the Safe Transport of Radioactive Material

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Lyul; Chung, K. K.; Lee, J. I.; Chang, S. Y.; Lee, T. Y

    2007-11-15

    This technical report describes the procedure and work responsibility along with the regulation and standard necessary for the safe transport of radioactive or contaminated materials. This report, therefore, can be effectively used to secure the public safety as well as to prevent the disastrous event which might be resulted from the transport process of radioactive materials by establishing a procedure and method on the safe packing, handling and transport of radioactive materials.

  3. Challenges of safe medication practice in paediatric care--a nursing perspective.

    Science.gov (United States)

    Star, Kristina; Nordin, Karin; Pöder, Ulrika; Edwards, I Ralph

    2013-05-01

    To explore nurses' experiences of handling medications in paediatric clinical practice, with a focus on factors that hinder and facilitate safe medication practices. Twenty nurses (registered nurses) from four paediatric wards at two hospitals in Sweden were interviewed in focus groups. The interviews were analysed using content analysis. Six themes emerged from the analysed interviews: the complexity specific for nurses working on paediatric wards is a hindrance to safe medication practices; nurses' concerns about medication errors cause a considerable psychological burden; the individual nurse works hard for safe medication practices and values support from other nurse colleagues; circumstances out of the ordinary are perceived as critical challenges for maintaining patient safety; nurses value clear instructions, guidelines and routines, but these are often missing, variable or changeable; management, other medical professionals, the pharmacy, the pharmaceutical industry and informatics support need to respond to the requirements of the nurses' working situations to improve safe medication practices. Weaknesses were apparent in the long chain of the medication-delivery process. A joint effort by different professions involved in that delivery process, and a nationwide collaboration between hospitals is recommended to increase safe medication practices in paediatric care. ©2013 Foundation Acta Paediatrica. Published by Blackwell Publishing Ltd.

  4. ETHEL's systems and facilities for safe management of tritiated wastes

    International Nuclear Information System (INIS)

    Mannone, F.; Dworschak, H.; Vassallo, G.

    1992-01-01

    The European Tritium Handling Experimental Laboratory (ETHEL) is a new tritium facility at the Commission of the European Community's Joint Research Centre, Ispra Site. The laboratory, destined to handle multigram amounts of tritium for safety related R and D purposes, is foreseen to start radioactive operations in late 1992. The general operation and maintenance of laboratory systems and future experiments will generate tritiated wastes in gaseous, liquid and solid forms. The management of such wastes under safe working conditions is a stringent laboratory requirement aimed at minimizing the risk of unacceptable tritium exposures to workers and the general public. This paper describes the main systems and facilities installed in ETHEL for the safe management of tritiated wastes

  5. Safe Handling of Oral Antineoplastic Medications: Focus on Targeted Therapeutics in the Home Setting

    Science.gov (United States)

    Cass, Yaakov; Connor, Thomas H.; Tabachnik, Alexander

    2017-01-01

    Introduction With the growing number of oral targeted therapies being approved for use in cancer therapy, the potential for long-term administration of these drugs to cancer patients is expanding. The use of these drugs in the home setting has the potential to expose family members and caregivers to them either through direct contact with the drugs or indirectly by exposure to the parent compounds and/or their active metabolites in contaminated patient's waste. Methods A systematic literature review was performed and the known adverse health effect of 32 oral targeted therapeutics is summarized. In particular, the carcinogenicity, genotoxicity, and embryo-foetal toxicity, along with the route of excretion were evaluated. Results Carcinogenicity testing has not been performed on most of the oral targeted therapeutics and the genotoxicity data are mixed. However, the majority of these drugs exhibit adverse reproductive effects, some of which are severe. Currently available data does not permit the possibility of a health hazard from inappropriate handling of drugs and contaminated patients waste to be ignored, especially in a long-term home setting. Further research is needed to understand these issues. Conclusions With the expanding use of targeted therapies in the home setting, family members and caregivers, especially those of reproductive risk age, are, potentially at risk. Overall basic education and related precautions should be taken to protect family members and caregivers from indirect or direct exposure from these drugs. Further investigations and discussion on this subject is warranted. PMID:27009803

  6. 9 CFR 381.125 - Special handling label requirements.

    Science.gov (United States)

    2010-01-01

    ... AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY.... The safe handling information shall be set off by a border and shall be one color type printed on a single color contrasting background whenever practical. (2) (i) The labels of the poultry products...

  7. Arsenic-safe drinking water and antioxidants for the management of arsenicosis patients

    Directory of Open Access Journals (Sweden)

    Salamat Khandker, Ranjit Kumar Dey, AZM Maidul Islam, Sheikh Akhtar Ahmad and Ifthaker-Al-Mahmud

    2006-12-01

    Full Text Available The role of arsenic-safe drinking water and antioxidants in the management of arsenicosis patients were observed. Two hundred and fifty patients of arsenicosis from an arsenic-affected area of Bangladesh were included and divided into five groups based on the source of drinking water (green- or red-marked tube well and intake of antioxidants (vitamin A, C and E. Melanosis improved in 43 patients of the group who took arsenic-safe drinking water from green-marked tube well and antioxidants regularly. Patients of the group who took green-marked tube well water regularly but not the antioxidant showed improvement in melanosis in 22 cases. The respondents who were using red-marked tube well water and antioxidants, only two of them improved; and all other respondents either deteriorated or did not improve. The respondents who were using red-marked tube well water but not the antioxidant, none did show any improvement of their illness. The respondents who took antioxidants irregularly and had irregular intake of safe water, were not considered to compare the prognosis of skin lesions. Regarding keratosis, the respondents who took green-marked tube well water regularly and antioxidant regularly, 8 of them improved, 1 case didn’t change; while the respondents who took green-marked tube well water regularly but not the antioxidant, 8 cases didn’t improve much but majority of them remain unchanged. Among the respondents of other groups, keratosis deteriorated. This study suggests that both arsenic-safe drinking water and use of antioxidants gave good result in improvement of the arsenicosis.

  8. Sociodemographic characteristics and handling of life-threatening ...

    African Journals Online (AJOL)

    Most TBAs deliver 4 newborn monthly, i.e. 148 (22.6%), and the mean number of newborn delivered monthly was 3.9. Concerning the mode of handling of the difficult cases, majority, i.e. 338 ... agenda of many global efforts, such as the safe motherhood .... of rural women and training of health attendants in rural areas.

  9. Biodiesel Handling and Use Guide (Fifth Edition)

    Energy Technology Data Exchange (ETDEWEB)

    Alleman, T.L.; McCormick, R.L.; Christensen, E.D.; Fioroni, G.; Moriarty. K.; Yanowitz, J.

    2016-11-08

    This document is a guide for those who blend, distribute, and use biodiesel and biodiesel blends. It provides basic information on the proper and safe use of biodiesel and biodiesel blends in engines and boilers, and is intended to help fleets, individual users, blenders, distributors, and those involved in related activities understand procedures for handling and using biodiesel fuels.

  10. The gas cushion technique as a handling means for the remote removal of tokamak segments

    International Nuclear Information System (INIS)

    Removille, J.; Stephano, R.

    1983-01-01

    The gas cushion technique has been studied as offering a compact, flexible and safe way of handling massive objects. The evolution of the gas-cushion handling philosophy is discussed and examples presented related to the displacements of different loads in the torus and in the reactor hall. A short technical comparison with the C-frame handling concept is made in the conclusion. (author)

  11. Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

    Energy Technology Data Exchange (ETDEWEB)

    Manohar S. Sohal; J. Stephen Herring

    2008-07-01

    Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable

  12. Torus sector handling system

    International Nuclear Information System (INIS)

    Grisham, D.L.

    1981-01-01

    A remote handling system is proposed for moving a torus sector of the accelerator from under the cryostat to a point where it can be handled by a crane and for the reverse process for a new sector. Equipment recommendations are presented, as well as possible alignment schemes. Some general comments about future remote-handling methods and the present capabilities of existing systems will also be included. The specific task to be addressed is the removal and replacement of a 425 to 450 ton torus sector. This requires a horizontal movement of approx. 10 m from a normal operating position to a point where its further transport can be accomplished by more conventional means (crane or floor transporter). The same horizontal movement is required for reinstallation, but a positional tolerance of 2 cm is required to allow reasonable fit-up for the vacuum seal from the radial frames to the torus sector. Since the sectors are not only heavy but rather tall and narrow, the transport system must provide a safe, stable, and repeatable method fo sector movement. This limited study indicates that the LAMPF-based method of transporting torus sectors offers a proven method of moving heavy items. In addition, the present state of the art in remote equipment is adequate for FED maintenance

  13. Asthma, guides for diagnostic and handling

    International Nuclear Information System (INIS)

    Salgado, Carlos E; Caballero A, Andres S; Garcia G, Elizabeth

    1999-01-01

    The paper defines the asthma, includes topics as diagnostic, handling of the asthma, special situations as asthma and pregnancy, handling of the asthmatic patient's perioperatory and occupational asthma

  14. Development of Pneumatic Transport System (PTS) for safe handling of uranium oxide powder in UMP/UED

    International Nuclear Information System (INIS)

    Manna, S.; Satpati, S.K.; Roy, S.B.

    2009-01-01

    Tonnage quantity radioactive uranium oxide powder of particle size sub micron to 100 micron is handled in Uranium Metal Plant (UMP), UED/BARC for production of nuclear grade uranium metal, required for fuelling research reactors - Dhruva and Cirus. A Pneumatic Transfer System (PTS) using vacuum has been introduced and is being used for handling radioactive powder to improve radiation protection

  15. A dynamic 3D biomechanical evaluation of the load on the low back during different patient-handling tasks.

    Science.gov (United States)

    Skotte, J H; Essendrop, M; Hansen, A F; Schibye, B

    2002-10-01

    The objective of this study was to investigate the low-back loading during common patient-handling tasks. Ten female health care workers without formal training in patient handling performed nine patient-handling tasks including turning, lifting and repositioning a male stroke patient. The low-back loading was quantified by net moment, compression, and shear forces at the L4/L5 joint, measured muscle activity (EMG) in erector spinae muscles and rate of perceived exertion (RPE; Borg scale). The experiments were videotaped with a 50Hz video system using five cameras, and the ground and bedside reaction forces of the health care worker were recorded by means of force platforms and force transducers on the bed. The biomechanical load was calculated using a dynamic 3D seven-segment model of the lower part of the body, and the forces at the L4/L5 joint were estimated by a 14 muscles cross-sectional model of the low back (optimisation procedure). Compression force and torque showed high task dependency whereas the EMG data and the RPE values were more dependent on the subject. The peak compression during two tasks involving lifting the patient (4132/4433N) was significantly higher than all other tasks. Four tasks involving repositioning the patient in the bed (3179/3091/2932/3094N) did not differ, but showed higher peak compression than two tasks turning the patient in the bed (1618/2197N). Thus, in this study the patient-handling tasks could be classified into three groups-characterised by lifting, repositioning or turning-with different levels of peak net torque and compression at the L4/L5 joint.

  16. Day surgery is effective and safe for patients with great saphenous ...

    African Journals Online (AJOL)

    2015-11-02

    Nov 2, 2015 ... Conclusion: DS for GSVV is an effective and safe procedure, which was the same as IS. ... DS could decrease the average medical cost for patients and hospital stays ... Access this article online ..... Dunmade AD, Alabi BS.

  17. Tritium handling experience at Atomic Energy of Canada Limited

    Energy Technology Data Exchange (ETDEWEB)

    Suppiah, S.; McCrimmon, K.; Lalonde, S.; Ryland, D.; Boniface, H.; Muirhead, C.; Castillo, I. [Atomic Energy of Canad Limited - AECL, Chalk River Laboratories, Chalk River, ON (Canada)

    2015-03-15

    Canada has been a leader in tritium handling technologies as a result of the successful CANDU reactor technology used for power production. Over the last 50 to 60 years, capabilities have been established in tritium handling and tritium management in CANDU stations, tritium removal processes for heavy and light water, tritium measurement and monitoring, and understanding the effects of tritium on the environment. This paper outlines details of tritium-related work currently being carried out at Atomic Energy of Canada Limited (AECL). It concerns the CECE (Combined Electrolysis and Catalytic Exchange) process for detritiation, tritium-compatible electrolysers, tritium permeation studies, and tritium powered batteries. It is worth noting that AECL offers a Tritium Safe-Handling Course to national and international participants, the course is a mixture of classroom sessions and hands-on practical exercises. The expertise and facilities available at AECL is ready to address technological needs of nuclear fusion and next-generation nuclear fission reactors related to tritium handling and related issues.

  18. Some considerations in the handling of fluorine and the chlorine fluorides

    International Nuclear Information System (INIS)

    Farrar, R.L. Jr.; Barber, E.J.

    1979-01-01

    This paper reviews many considerations in the safe handling of fluorine and the chlorine fluorides. The physical, chemical, and toxicological properties of the materials are reviewed. Proper choice of materials of construction and materials in contact with the active gases are considered. The survey includes safe practices in design and operation of experiments and processes. Soda lime traps and caustic scrubbing are reviewed for fluorine disposal methods. Finally some explosive reactions and explosive situations are discussed

  19. A pilot survey of the U.S. medical waste industry to determine training needs for safely handling highly infectious waste.

    Science.gov (United States)

    Le, Aurora B; Hoboy, Selin; Germain, Anne; Miller, Hal; Thompson, Richard; Herstein, Jocelyn J; Jelden, Katelyn C; Beam, Elizabeth L; Gibbs, Shawn G; Lowe, John J

    2018-02-01

    The recent Ebola outbreak led to the development of Ebola virus disease (EVD) best practices in clinical settings. However, after the care of EVD patients, proper medical waste management and disposal was identified as a crucial component to containing the virus. Category A waste-contaminated with EVD and other highly infectious pathogens-is strictly regulated by governmental agencies, and led to only several facilities willing to accept the waste. A pilot survey was administered to determine if U.S. medical waste facilities are prepared to handle or transport category A waste, and to determine waste workers' current extent of training to handle highly infectious waste. Sixty-eight percent of survey respondents indicated they had not determined if their facility would accept category A waste. Of those that had acquired a special permit, 67% had yet to modify their permit since the EVD outbreak. This pilot survey underscores gaps in the medical waste industry to handle and respond to category A waste. Furthermore, this study affirms reports a limited number of processing facilities are capable or willing to accept category A waste. Developing the proper management of infectious disease materials is essential to close the gaps identified so that states and governmental entities can act accordingly based on the regulations and guidance developed, and to ensure public safety. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Orientation of handle for successful prosthetic treatment in patients with an anatomic compromise after a maxillectomy.

    Science.gov (United States)

    Sumita, Yuka I; Hattori, Mariko; Elbashti, Mahmoud E; Taniguchi, Hisashi

    2017-05-01

    This clinical technique provides a key procedure for successful prosthetic treatment in patients with an anatomical compromise after a maxillectomy. When making a preliminary impression, the clinician must keep the handle of the stock tray parallel to the patient's interpupillary line extraorally to maintain the correct position of the tray and to make a record of the inclination of the occlusal plane. This simple consideration during this first step of making a preliminary impression can be an important guide for both dentists and dental technicians. Information about the correct positioning of the tray and the inclination of the occlusal plane obtained by using a stock tray handle will greatly reduce the stress experienced by dentists, dental technicians, and patients during the fabrication of the prosthesis and will ultimately lead to successful prosthetic treatment in patients with anatomic compromise resulting from a maxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. The design of in-cell crane handling systems for nuclear plants

    International Nuclear Information System (INIS)

    Hansford, S.M.; Scott, R.

    1992-01-01

    The reprocessing and waste management facilities at (BNFL's) British Nuclear Fuels Limited's Sellafield site make extensive use of crane handling systems. These range from conventional mechanical handling operations as used generally in industry to high integrity applications through to remote robotic handling operations in radiation environments. This paper describes the design methodologies developed for the design of crane systems for remote handling operations - in-cell crane systems. In most applications the in-cell crane systems are an integral part of the plant process equipment and reliable and safe operations are a key design parameter. Outlined are the techniques developed to achieve high levels of crane system availability for operations in hazardous radiation environments. These techniques are now well established and proven through many years of successful plant operation. A recent application of in-cell crane handling systems design for process duty application is described. The benefits of a systematic design approach and a functionally-based engineering organization are also highlighted. (author)

  2. Design of startup neutron detector handling mechanism instrumentation

    International Nuclear Information System (INIS)

    Upadhyay, Chandra Kant; Sivaramakrishna, M.; Nagaraj, C.P.; Madhusoodanan, K.

    2010-01-01

    In PFBR, to monitor the reactor during first fuel loading and low power operation, special provision is made in the central fuel subassembly to accommodate the neutron detectors. During fuel handling operations, these detectors need to be lifted up to facilitate plug rotation. These detectors are also need to be lifted from the core to save their life, during intermediate and high power operations. Towards this, a mobile assembly containing these detectors is made with lowering and retracting provision. To control this operation, constant speed motor, torque limiter, proximity switch, wire drawn potentiometer, magnetic reed switches are provided. To ensure a smooth and safe handling of this assembly, control logic with necessary interlocks is developed. (author)

  3. Detection of some safe plant-derived foods for LTP-allergic patients.

    Science.gov (United States)

    Asero, Riccardo; Mistrello, Gianni; Roncarolo, Daniela; Amato, Stefano

    2007-01-01

    Lipid transfer protein (LTP) is a widely cross-reacting plant pan-allergen. Adverse reactions to Rosaceae, tree nuts, peanut, beer, maize, mustard, asparagus, grapes, mulberry, cabbage, dates, orange, fig, kiwi, lupine, fennel, celery, tomato, eggplant, lettuce, chestnut and pineapple have been recorded. To detect vegetable foods to be regarded as safe for LTP-allergic patients. Tolerance/intolerance to a large spectrum of vegetable foods other than Rosaceae, tree nuts and peanut was assessed by interview in 49 subjects monosensitized to LTP and in three distinct groups of controls monosensitized to Bet v 1 (n = 24) or Bet v 2 (n = 18), or sensitized to both LTP and birch pollen (n = 16), all with a history of vegetable food allergy. Patients and controls underwent skin prick test (SPT) with a large spectrum of vegetable foods. The absence of IgE reactivity to foods that were negative in both clinical history and SPT was confirmed by immunoblot analysis and their clinical tolerance was finally assessed by open oral challenge (50 g per food). All patients reported tolerance and showed negative SPT to carrot, potato, banana and melon; these foods scored positive in SPT and elicited clinical symptoms in a significant proportion of patients from all three control groups. All patients tolerated these four foods on oral challenge. Immunoblot analysis confirmed the lack of IgE reactivity to these foods by LTP-allergic patients. Carrot, potato, banana and melon seem safe for LTP-allergic patients. This finding may be helpful for a better management of allergy to LTP.

  4. Magnetic resonance imaging of meniscal bucket-handle tears

    International Nuclear Information System (INIS)

    Dfouni, N.; Garcia, J.; Kindynis, Ph.; Bosson, D.

    1997-01-01

    To define MR signs of meniscal bucket-handle tears and evaluate the diagnostic efficiency of this technique. Retrospective study of 30 patients with a meniscal bucket-handle tear and 30 with a different type of tear, all proven by arthroscopy. The following MR signs of a bucket-handle tear were evaluated: 'separate meniscal fragment, 'double posterior cruciate ligament', 'snake sign' and 'double anterior horn'. A correct diagnosis of a bucket-handle tear was only made in 18/30 of patients. Several of the MR signs were seen in the same patient in 17 cases. A double posterior cruciate ligament was present only in cases of medial meniscus tears. The 12 menisci without these signs, and therefore not diagnosed as bucket-handle tears, were all classified as meniscal tears on the basis of signal extending to the meniscal surface. Nine of these were not displaced into the inter-condylar notch at arthroscopy. The interobserver agreement was excellent: kappa 0.88. The diagnosis of a bucket-handle meniscal tear, if it is displaced, can be made when one or more of the four MR evaluated signs are present. Other forms of meniscal tears are only exceptionally diagnosed as bucket-handle tears. (authors)

  5. Fission reactor recycling pump handling device

    International Nuclear Information System (INIS)

    Togasawa, Hiroshi; Komita, Hideo; Susuki, Shoji; Endo, Takio; Yamamoto, Tetsuzo; Takahashi, Hideaki; Saito, Noboru.

    1991-01-01

    This invention provides a device for handling a recycling pump in a nuclear reactor upon periodical inspections in a BWR type power plant. That is, in a handling device comprising a support for supporting components of a recycling pump, and a lifter for vertically moving the support below a motor case disposed passing through a reactor pressure vessel, a weight is disposed below the support. Then, the center of gravity of the components, the support and the entire weight is substantially aligned with the position for the support. With such a constitution, the components can be moved vertically to the motor case extremely safely, to remarkably suppress vibrations. Further, the operation safety can remarkably be improved by preventing turning down upon occurrence of earthquakes. Further, since vibration-proof jigs as in a prior art can be saved, operation efficiency can be improved. (I.S.)

  6. Fission reactor recycling pump handling device

    Energy Technology Data Exchange (ETDEWEB)

    Togasawa, Hiroshi; Komita, Hideo; Susuki, Shoji; Endo, Takio; Yamamoto, Tetsuzo; Takahashi, Hideaki; Saito, Noboru

    1991-06-24

    This invention provides a device for handling a recycling pump in a nuclear reactor upon periodical inspections in a BWR type power plant. That is, in a handling device comprising a support for supporting components of a recycling pump, and a lifter for vertically moving the support below a motor case disposed passing through a reactor pressure vessel, a weight is disposed below the support. Then, the center of gravity of the components, the support and the entire weight is substantially aligned with the position for the support. With such a constitution, the components can be moved vertically to the motor case extremely safely, to remarkably suppress vibrations. Further, the operation safety can remarkably be improved by preventing turning down upon occurrence of earthquakes. Further, since vibration-proof jigs as in a prior art can be saved, operation efficiency can be improved. (I.S.).

  7. Safe clinical practice for patients hospitalised in a suicidal crisis: a study protocol for a qualitative case study.

    Science.gov (United States)

    Berg, Siv Hilde; Rørtveit, Kristine; Walby, Fredrik A; Aase, Karina

    2017-01-27

    Suicide prevention in psychiatric care is arguably complex and incompletely understood as a patient safety issue. A resilient healthcare approach provides perspectives through which to understand this complexity by understanding everyday clinical practice. By including suicidal patients and healthcare professionals as sources of knowledge, a deeper understanding of what constitutes safe clinical practice can be achieved. This planned study aims to adopt the perspective of resilient healthcare to provide a deeper understanding of safe clinical practice for suicidal patients in psychiatric inpatient care. It will describe the experienced components and conditions of safe clinical practice and the experienced practice of patient safety. The study will apply a descriptive case study approach consisting of qualitative semistructured interviews and focus groups. The data sources are hospitalised patients in a suicidal crisis and healthcare professionals in clinical practice. This study was approved by the Regional Ethics Committee (2016/34). The results will be disseminated through scientific articles, a PhD dissertation, and national and international conferences. These findings can generate knowledge to be integrated into the practice of safety for suicidal inpatients in Norway and to improve the feasibility of patient safety measures. Theoretical generalisations can be drawn regarding safe clinical practice by taking into account the experiences of patients and healthcare professionals. Thus, this study can inform the conceptual development of safe clinical practice for suicidal patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Analysis of Personal Hygiene and Food Handling on Patients Food Managementt in Rsup Dr. Mohammad Hoesin Palembang

    OpenAIRE

    Mirawati, Mirawati; Sitorus, Rico Januar; Hasyim, Hamzah

    2011-01-01

    Background : Hospital food hygiene and sanitation are generally less awake, which originated in the less hygienic food processing particularly related to personal hygiene of food handlers and poor food handling at every stage of implementation. This study aims to analyze the personal hygiene and food handling on Patients Food management in RSUP Dr. Mohammad Hoesin Palembang, 2010. Method : This study was descriptive using a qualitative approach. Sources of information in this study amounted...

  9. Haptic shared control improves hot cell remote handling despite controller inaccuracies

    NARCIS (Netherlands)

    van Oosterhout, J.; Abbink, D. A.; Koning, J. F.; Boessenkool, H.; Wildenbeest, J. G. W.; Heemskerk, C. J. M.

    2013-01-01

    A promising solution to improve task performance in ITER hot cell remote handling is the use of haptic shared control. Haptic shared control can assist the human operator along a safe and optimal path with continuous guiding forces from an intelligent autonomous controller. Previous research tested

  10. Development of spent fuel remote handling technology

    International Nuclear Information System (INIS)

    Yoon, Ji Sup; Park, B. S.; Park, Y. S.; Oh, S. C.; Kim, S. H.; Cho, M. W.; Hong, D. H.

    1997-12-01

    Since the nation's policy on spent fuel management is not finalized, the technical items commonly required for safe management and recycling of spent fuel - remote technologies of transportation, inspection, maintenance, and disassembly of spent fuel - are selected and pursued. In this regards, the following R and D activities are carried out : collision free transportation of spent fuel assembly, mechanical disassembly of spent nuclear fuel and graphical simulation of fuel handling / disassembly process. (author). 36 refs., 16 tabs., 77 figs

  11. The safe home project.

    Science.gov (United States)

    Arphorn, Sara; Jiraniratisai, Sopaphan; Rungtakul, Rungsri; Phutta, Nikom

    2011-12-01

    The Thai Health Promotion Foundation supported the Improvement of Quality of Life of Informal Workers project in Ban Luang District, Amphur Photaram, Ratchaburi Province. There were many informal workers in Ban Luang District. Sweet-crispy fish producers in Ban Luang were the largest group among the sweet-crispy fish producers in Thailand. This project was aimed at improving living and working conditions of informal workers, with a focus on the sweet-crispy fish group. Good practices of improved living and working conditions were used to help informal workers build safe, healthy and productive work environments. These informal workers often worked in substandard conditions and were exposed to various hazards in the working area. These hazards included risk of exposure to hot work environment, ergonomics-related injuries, chemical hazards, electrical hazards etc. Ergonomics problems were commonly in the sweet-crispy fish group. Unnatural postures such as prolonged sitting were performed dominantly. One hundred and fifty informal workers participated in this project. Occupational health volunteers were selected to encourage occupational health and safety in four groups of informal workers in 2009. The occupational health volunteers trained in 2008 were farmers, beauty salon workers and doll makers. The occupational health and safety knowledge is extended to a new informal worker group: sweet-crispy fish producer, in 2009. The occupational health and safety training for sweet-crispy fish group is conducted by occupational health volunteers. The occupational health volunteers increased their skills and knowledge assist in to make safe home and safe community through participatory oriented training. The improvement of living and working condition is conducted by using a modified WISH, Work Improvement for Safe Home, checklist. The plans of improvement were recorded. The informal workers showed improvement mostly on material handling and storage. The safe uses and safe

  12. Contamination confinement system of irradiated materials handling laboratories

    International Nuclear Information System (INIS)

    Lobao, A. dos S.T.; Araujo, J.A. de; Camilo, R.L.

    1988-06-01

    A study to prevent radioctivity release in lab scale is presented. As a basis for the design all the limits established by the IAEA for ventilation systems were observed. An evaluation of the different parameters involved in the design have been made, resulting in the especification of the working areas, ducts and filtering systems in order to get the best conditions for the safe handling of irradiated materials. (author) [pt

  13. Do Technical Aids for Patient Handling Prevent Musculoskeletal Complaints in Health Care Workers?—A Systematic Review of Intervention Studies

    Directory of Open Access Journals (Sweden)

    Janice Hegewald

    2018-03-01

    Full Text Available The physical load ensuing from the repositioning and moving of patients puts health care workers at risk of musculoskeletal complaints. Technical equipment developed to aid with patient handling should reduce physical strain and workload; however, the efficacy of these aids in preventing musculoskeletal disorders and complaints is still unclear. A systematic review of controlled intervention studies was conducted to examine if the risk of musculoskeletal complaints and disorders is reduced by technical patient handling equipment. MEDLINE®/PubMed®, EMBASE®, Allied and Complementary Medicine Database (AMED, and Cumulative Index of Nursing and Allied Health Literature (CINAHL® were searched using terms for nursing, caregiving, technical aids, musculoskeletal injuries, and complaints. Randomized controlled trials and controlled before-after studies of interventions including technical patient handling equipment were included. The titles and abstracts of 9554 publications and 97 full-texts were screened by two reviewers. The qualitative synthesis included one randomized controlled trial (RCT and ten controlled before-after studies. A meta-analysis of four studies resulted in a pooled risk ratio for musculoskeletal injury claims (post-intervention of 0.78 (95% confidence interval 0.68–0.90. Overall, the methodological quality of the studies was poor and the results often based on administrative injury claim data, introducing potential selection bias. Interventions with technical patient handling aids appear to prevent musculoskeletal complaints, but the certainty of the evidence according to GRADE approach ranged from low to very low.

  14. Safe Handling of Snakes in an ED Setting.

    Science.gov (United States)

    Cockrell, Melanie; Swanson, Kristofer; Sanders, April; Prater, Samuel; von Wenckstern, Toni; Mick, JoAnn

    2017-01-01

    Efforts to improve consistency in management of snakes and venomous snake bites in the emergency department (ED) can improve patient and staff safety and outcomes, as well as improve surveillance data accuracy. The emergency department at a large academic medical center identified an opportunity to implement a standardized process for snake disposal and identification to reduce staff risk exposure to snake venom from snakes patients brought with them to the ED. A local snake consultation vendor and zoo Herpetologist assisted with development of a process for snake identification and disposal. All snakes have been identified and securely disposed of using the newly implemented process and no safety incidents have been reported. Other emergency department settings may consider developing a standardized process for snake disposal using listed specialized consultants combined with local resources and suppliers to promote employee and patient safety. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  15. Management of remote-handled defense transuranic wastes

    International Nuclear Information System (INIS)

    Ebra, M.A.; Pierce, G.D.; Carson, P.H.

    1988-01-01

    Transuranic (TRU) wastes generated by defense-related activities are scheduled for emplacement at the Waste Isolation Pilot Plant (WIPP) in New Mexico beginning in October 1988. After five years of operation as a research and development facility, the WIPP may be designated as a permanent repository for these wastes, if it has been demonstrated that this deep, geologically stable formation is a safe disposal option. Defense TRU wastes are currently stored at various Department of Energy (DOE) sites across the nation. Approximately 2% by volume of currently stored TRU wastes are defined, on the basis of dose rates, as remote-handled (RH). RH wastes continue to be generated at various locations operated by DOE contractors. They require special handling and processing prior to and during emplacement in the WIPP. This paper describes the strategy for managing defense RH TRU wastes

  16. Development and evaluation of a multifaceted ergonomics program to prevent injuries associated with patient handling tasks.

    Science.gov (United States)

    Nelson, Audrey; Matz, Mary; Chen, Fangfei; Siddharthan, Kris; Lloyd, John; Fragala, Guy

    2006-08-01

    Nurses have one of the highest rates of work-related musculoskeletal injury of any profession. Over the past 30 years, efforts to reduce work-related musculoskeletal disorders in nurses have been largely unsuccessful. The primary goal of this program was to create safer working environments for nursing staff who provide direct patient care. Our first objective was to design and implement a multifaceted program that successfully integrated evidence-based practice, technology, and safety improvement. The second objective was to evaluate the impact of the program on injury rate, lost and modified work days, job satisfaction, self-reported unsafe patient handling acts, level of support for program, staff and patient acceptance, program effectiveness, costs, and return on investment. The intervention included six program elements: (1) Ergonomic Assessment Protocol, (2) Patient Handling Assessment Criteria and Decision Algorithms, (3) Peer Leader role, "Back Injury Resource Nurses", (4) State-of-the-art Equipment, (5) After Action Reviews, and (6) No Lift Policy. A pre-/post design without a control group was used to evaluate the effectiveness of a patient care ergonomics program on 23 high risk units (19 nursing home care units and 4 spinal cord injury units) in 7 facilities. Injury rates, lost work days, modified work days, job satisfaction, staff , and patient acceptance, program effectiveness, and program costs/savings were compared over two nine month periods: pre-intervention (May 2001-January 2002) and post-intervention (March 2002-November 2002). Data were collected prospectively through surveys, weekly process logs, injury logs, and cost logs. The program elements resulted in a statistically significant decrease in the rate of musculoskeletal injuries as well as the number of modified duty days taken per injury. While the total number of lost workdays decreased by 18% post-intervention, this difference was not statistically significant. There were statistically

  17. [Clinical Handling of Patients with Dissociative Disorders].

    Science.gov (United States)

    Okano, Kenichiro

    2015-01-01

    This paper discusses the way informed psychiatrists are expected to handle dissociative patients in clinical situations, with a specific focus on dissociative identity disorders and dissociative fugue. On the initial interview with dissociative patients, information on their history of trauma and any nascent dissociative symptoms in their childhood should be carefully obtained. Their level of stress in their current life should also be assessed in order to understand their symptomatology, as well as to predict their future clinical course. A psychoeducational approach is crucial; it might be helpful to give information on dissociative disorder to these patients as well as their family members in order to promote their adherence to treatment. Regarding the symptomatology of dissociative disorders, detailed symptoms and the general clinical course are presented. It was stressed that dissociative identity disorder and dissociative fugue, the most high-profile dissociative disorders, are essentially different in their etiology and clinical presentation. Dissociative disorders are often confused with and misdiagnosed as psychotic disorders, such as schizophrenia. Other conditions considered in terms of the differential diagnosis include borderline personality disorder as well as temporal lobe epilepsy. Lastly, the therapeutic approach to dissociative identity disorder is discussed. Each dissociative identity should be understood as potentially representing some traumatically stressful event in the past. The therapist should be careful not to excessively promote the creation or elaboration of any dissociative identities. Three stages are proposed in the individual psychotherapeutic process. In the initial stage, a secure environment and stabilization of symptoms should be sought. The second stage consists of aiding the "host" personality to make use of other more adaptive coping skills in their life. The third stage involves coaching as well as continuous awareness of

  18. Development of spent fuel remote handling technology

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Sup; Park, B S; Park, Y S; Oh, S C; Kim, S H; Cho, M W; Hong, D H

    1997-12-01

    Since the nation`s policy on spent fuel management is not finalized, the technical items commonly required for safe management and recycling of spent fuel - remote technologies of transportation, inspection, maintenance, and disassembly of spent fuel - are selected and pursued. In this regards, the following R and D activities are carried out : collision free transportation of spent fuel assembly, mechanical disassembly of spent nuclear fuel and graphical simulation of fuel handling / disassembly process. (author). 36 refs., 16 tabs., 77 figs

  19. Biosafety Procedure for Safe Handling of Genetically Modified Plant Materials in Bio Design Facility

    International Nuclear Information System (INIS)

    Zaiton Ahmad; Shuhaimi Shamsudin; Mohamed Najli Mohamed Yasin; Affrida Abu Hassan; Mohd Zaid Hassan; Rusli Ibrahim

    2015-01-01

    Bio Design Facility is the specifically designed glass house for propagation, screening and analysis of high quality plant varieties developed through biotechnology or a combination of nuclear technology and biotechnology. High quality plant varieties especially genetically modified plants (GMO) require a special glass house facility for propagation and screening to isolate them from cross-pollinating with wild type varieties in surrounding ecosystem, and for carrying out evaluation of possible risks of the plants to human, animal and environment before they are proven safe for field trials or commercial release. This facility which was developed under the Ninth Malaysia Plan is classified as the Plant Containment Level 2 and is compliance with the bio safety regulations and guidance for the safe release of GMO according to Malaysian Bio safety Act 2007. Bio Design Facility is fully operational since 2010 and in 2012, it has also been certified as the glass house for post-entry quarantine by The Department of Agriculture. This paper summarizes the bio safety procedure for a safe, controlled and contained growing and evaluation of GMO in Bio Design Facility. This procedure covers the physical (containment and equipment's) and operational (including responsibility, code of practice, growing, decontamination and disposal of plant materials, emergency and contingency plan) aspects of the facility. (author)

  20. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  1. Structural acceptance criteria Remote Handling Building Tritium Extraction Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mertz, G.

    1999-12-16

    This structural acceptance criteria contains the requirements for the structural analysis and design of the Remote Handling Building (RHB) in the Tritium Extraction Facility (TEF). The purpose of this acceptance criteria is to identify the specific criteria and methods that will ensure a structurally robust building that will safely perform its intended function and comply with the applicable Department of Energy (DOE) structural requirements.

  2. Structural acceptance criteria Remote Handling Building Tritium Extraction Facility

    International Nuclear Information System (INIS)

    Mertz, G.

    1999-01-01

    This structural acceptance criteria contains the requirements for the structural analysis and design of the Remote Handling Building (RHB) in the Tritium Extraction Facility (TEF). The purpose of this acceptance criteria is to identify the specific criteria and methods that will ensure a structurally robust building that will safely perform its intended function and comply with the applicable Department of Energy (DOE) structural requirements

  3. Probing forces of menisci: what levels are safe for arthroscopic surgery

    NARCIS (Netherlands)

    Tuijthof, Gabriëlle J. M.; Horeman, Tim; Schafroth, Matthias U.; Blankevoort, Leendert; Kerkhoffs, Gino M. M. J.

    2011-01-01

    To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a

  4. Handling knowledge on osteoporosis - a qualitative study

    DEFF Research Database (Denmark)

    Nielsen, Dorthe; Huniche, Lotte; Brixen, Kim

    2013-01-01

    Scand J Caring Sci; 2012 Handling knowledge on osteoporosis - a qualitative study The aim of this qualitative study was to increase understanding of the importance of osteoporosis information and knowledge for patients' ways of handling osteoporosis in their everyday lives. Interviews were...

  5. Musculoskeletal complaints among nurses related to patient handling tasks and psychosocial factors - Based on logbook registrations

    DEFF Research Database (Denmark)

    Warming, S.; Precht, D.H.; Suadicani, P.

    2009-01-01

    The aims were to evaluate the inter-method reliability of a registration sheet for patient handling tasks, to study the day-to-day variation of musculoskeletal complaints (MSC) and to examine whether patient handling tasks and psychosocial factors were associated with MSC. Nurses (n = 148...... transfer and care tasks. The numbers of nurses reporting MSC and the level of pain increased significantly during the three working days (15%-30% and 17%-37%, respectively) and decreased on the day off. Stress and transfer task were associated with LPB and transfer tasks were associated with KP. Our...... results confirm a relationship between work factors and MSC and indicate that logs could be one way to obtain a better understanding of the complex interaction of various nursing working conditions in relation to MSC. (C) 2008 Elsevier Ltd. All rights reserved Udgivelsesdato: 2009/7...

  6. A Review of Toxicity and Use and Handling Considerations for Guanidine, Guanidine Hydrochloride, and Urea.

    Energy Technology Data Exchange (ETDEWEB)

    Ertell, Katherine GB

    2006-03-27

    This is a technical report prepared for Oregon Sustainable Energy, LLC, under Agreement 06-19 with PNNL's Office of Small Business Programs. The request was to perform a review of the toxicity and safe handling of guanidine. The request was later amended to add urea. This report summarizes the toxicity data available in the scientific literature and provides an interpretation of the results and recommendations for handling these compounds.

  7. Application of advanced handling techniques to transportation cask design

    International Nuclear Information System (INIS)

    Bennett, P.C.

    1992-01-01

    Sandia National Laboratories supports the US Department of Energy (DOE) Office of Civilian Radioactive Waste Management (OCRWM) applying technology to the safe transport of nuclear waste. Part of that development effort includes investigation of advanced handling technologies for automation of cask operations at nuclear waste receiving facilities. Although low radiation levels are expected near transport cask surfaces, cumulative occupational exposure at a receiving facility can be significant. Remote automated cask handling has the potential to reduce both the occupational exposure and the time necessary to process a cask. Thus, automated handling is consistent with DOE efforts to reduce the lifecycle costs of the waste disposal system and to maintain public and occupational radiological risks as low as reasonably achievable. This paper describes the development of advanced handling laboratory mock-ups and demonstrations for spent fuel casks. Utilizing the control enhancements described below, demonstrations have been carried out including cask location and identification, contact and non-contact surveys, impact limiter removal, tiedown release, uprighting, swing-free movement, gas sampling, and lid removal operations. Manually controlled movement around a cask under off-normal conditions has also been demonstrated

  8. Fuel handling and storage systems in nuclear power plants

    International Nuclear Information System (INIS)

    1984-01-01

    The scope of this Guide includes the design of handling and storage facilities for fuel assemblies from the receipt of fuel into the nuclear power plant until the fuel departs from that plant. The unirradiated fuel considered in this Guide is assumed not to exhibit any significant level of radiation so that it can be handled without shielding or cooling. This Guide also gives limited consideration to the handling and storage of certain core components. While the general design and safety principles are discussed in Section 2 of this Guide, more specific design requirements for the handling and storage of fuel are given in detailed sections which follow the general design and safety principles. Further useful information is to be found in the IAEA Technical Reports Series No. 189 ''Storage, Handling and Movement of Fuel and Related Components at Nuclear Power Plants'' and No. 198 ''Guide to the Safe Handling of Radioactive Wastes at Nuclear Power Plants''. However, the scope of the Guide does not include consideration of the following: (1) The various reactor physics questions associated with fuel and absorber loading and unloading into the core; (2) The design aspects of preparation of the reactor for fuel loading (such as the removal of the pressure vessel head for a light water reactor) and restoration after loading; (3) The design of shipping casks; (4) Fuel storage of a long-term nature exceeding the design lifetime of the nuclear power plant; (5) Unirradiated fuel containing plutonium

  9. Adoption of the B2SAFE EUDAT replication service by the EPOS community

    Science.gov (United States)

    Cacciari, Claudio; Fares, Massimo; Fiameni, Giuseppe; Michelini, Alberto; Danecek, Peter; Wittenburg, Peter

    2014-05-01

    B2SAFE is the EUDAT service for moving and replicating data between sites and storage systems for different purposes. The goal of B2SAFE is to keep the data from a repository safe by replicating it across different geographical and administrative zones according to a set of well-defined policies. It is also a way to store large volumes of data permanently at those sites which are providing powerful on-demand data analysis facilities. In particular, B2SAFE operates on the domain of registered data where data objects are referable via persistent identifiers (PIDs). B2SAFE is more than just copying data because the PIDs must be carefully managed when data objects are moved or replicated. The EUDAT B2SAFE Service offers functionality to replicate datasets across different data centres in a safe and efficient way while maintaining all information required to easily find and query information about the replica locations. The information about the replica locations and other important information is stored in PID records, each managed in separate administrative domains. The B2SAFE Service is implemented as an iRODS module providing a set of iRODS rules or policies to interface with the EPIC handle API and uses the iRODS middleware to replicate datasets from a source data (or community) centre to a destination data centre. The definition of the dataset(s) to replicate is flexible and up to the communities using the B2SAFE service. While the B2SAFE is internally using the EPIC handle API, communities have the choice to use any PID system they prefer to assign PIDs to their digital objects. A reference to one or more EUDAT B2SAFE PIDs is returned by the B2SAFE service when a dataset is replicated. The presentation will introduce the problem space of B2SAFE, presents the achievements that have been made during the last year for enabling communities to make use of the B2SAFE service, demonstrates a EPOS use cases, outlines the commonalities and differences between the policies

  10. Water hydraulic manipulator for fail safe and fault tolerant remote handling operations at ITER

    International Nuclear Information System (INIS)

    Nieminen, Peetu; Esque, Salvador; Muhammad, Ali; Mattila, Jouni; Vaeyrynen, Jukka; Siuko, Mikko; Vilenius, Matti

    2009-01-01

    Department of Intelligent Hydraulics and Automation (IHA) of Tampere University of Technology has been involved in the European Fusion program since 1994 within the ITER reactor maintenance activities. In this paper we discuss the design and development of a six degrees of freedom water hydraulic manipulator with a force feedback for teleoperation tasks. The manipulator is planned to be delivered to Divertor Test Platform 2 (DTP2) during year 2008. The paper also discusses the possibility to improve the fail safe and redundant operation of the manipulator. During the design of the water hydraulic manipulator, special provisions have been made in order to meet the safety requirements such as servo valve block for redundant operation and safety vane brakes for fail safe operation.

  11. Safe patient care - safety culture and risk management in otorhinolaryngology.

    Science.gov (United States)

    St Pierre, Michael

    2013-12-13

    Safety culture is positioned at the heart of an organization's vulnerability to error because of its role in framing organizational awareness to risk and in providing and sustaining effective strategies of risk management. Safety related attitudes of leadership and management play a crucial role in the development of a mature safety culture ("top-down process"). A type marker for organizational culture and thus a predictor for an organization's maturity in respect to safety is information flow and in particular an organization's general way of coping with information that suggests anomaly. As all values and beliefs, relationships, learning, and other aspects of organizational safety culture are about sharing and processing information, safety culture has been termed "informed culture". An informed culture is free of blame and open for information provided by incidents. "Incident reporting systems" are the backbone of a reporting culture, where good information flow is likely to support and encourage other kinds of cooperative behavior, such as problem solving, innovation, and inter-departmental bridging. Another facet of an informed culture is the free flow of information during perioperative patient care. The World Health Organization's safe surgery checklist" is the most prevalent example of a standardized information exchange aimed at preventing patient harm due to information deficit. In routine tasks mandatory standard operating procedures have gained widespread acceptance in guaranteeing the highest possible process quality. Technical and non-technical skills of healthcare professionals are the decisive human resource for an efficient and safe delivery of patient care and the avoidance of errors. The systematic enhancement of staff qualification by providing training opportunities can be a major investment in patient safety. In recent years several otorhinolaryngology departments have started to incorporate stimulation based team trainings into their

  12. [Safe patient care: safety culture and risk management in otorhinolaryngology].

    Science.gov (United States)

    St Pierre, M

    2013-04-01

    Safety culture is positioned at the heart of an organisation's vulnerability to error because of its role in framing organizational awareness to risk and in providing and sustaining effective strategies of risk management. Safety related attitudes of leadership and management play a crucial role in the development of a mature safety culture ("top-down process"). A type marker for organizational culture and thus a predictor for an organizations maturity in respect to safety is information flow and in particular an organization's general way of coping with information that suggests anomaly. As all values and beliefs, relationships, learning, and other aspects of organizational safety culture are about sharing and processing information, safety culture has been termed "informed culture". An informed culture is free of blame and open for information provided by incidents. "Incident reporting systems" are the backbone of a reporting culture, where good information flow is likely to support and encourage other kinds of cooperative behavior, such as problem solving, innovation, and inter-departmental bridging. Another facet of an informed culture is the free flow of information during perioperative patient care. The World Health Organisation's "safe surgery checklist" is the most prevalent example of a standardized information exchange aimed at preventing patient harm due to information deficit. In routine tasks mandatory standard operating procedures have gained widespread acceptance in guaranteeing the highest possible process quality.Technical and non-technical skills of healthcare professionals are the decisive human resource for an efficient and safe delivery of patient care and the avoidance of errors. The systematic enhancement of staff qualification by providing training opportunities can be a major investment in patient safety. In recent years several otorhinolaryngology departments have started to incorporate simulation based team trainings into their curriculum

  13. Probing forces of menisci : What levels are safe for arthroscopic surgery

    NARCIS (Netherlands)

    Tuijthof, G.J.M.; Horeman, T.; Schafroth, M.U.; Blankevoort, L.; Kerkhoffs, G.M.M.J.

    2010-01-01

    Purpose To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a

  14. Food Handling Behaviors Observed in Consumers When Cooking Poultry and Eggs.

    Science.gov (United States)

    Maughan, Curtis; Chambers, Edgar; Godwin, Sandria; Chambers, Delores; Cates, Sheryl; Koppel, Kadri

    2016-06-01

    Previous research has shown that many consumers do not follow recommended food safety practices for cooking poultry and eggs, which can lead to exposure to Salmonella and Campylobacter. Past research has been done primarily through surveys and interviews, rather than observations. The objective of this project was to determine through observations whether consumers follow food safety guidelines. Consumers (n = 101) divided among three locations (Manhattan, KS; Kansas City, MO area; and Nashville, TN) were observed as they prepared a baked whole chicken breast, a pan-fried ground turkey patty, a fried egg, and scrambled eggs. The end point temperature for the cooked products was taken (outside the view of consumers) within 30 s after the consumers indicated they were finished cooking. Thermometer use while cooking was low, although marginally higher than that of some previous studies: only 37% of consumers used a thermometer for chicken breasts and only 22% for turkey patties. No one used a thermometer for fried or scrambled eggs. Only 77% of the chicken and 69% of the turkey was cooked to a safe temperature (165°F [74°C]), and 77% of scrambled and 49% of fried eggs reached a safe temperature (160°F [71°C]). Safe hand washing was noted in only 40% of respondents after handling the chicken breast and 44% after handling the ground turkey patty. This value decreased to 15% after handling raw eggs for fried eggs and to 17% for scrambled eggs. These results show that there is a high prevalence of unsafe behaviors (undercooking and poor hand washing technique) when cooking poultry and eggs and a great need for improvement in consumer behavior with poultry and eggs.

  15. Nurses infection prevention practices in handling injections: A case ...

    African Journals Online (AJOL)

    The adherence to basic infection prevention procedures/aseptic techniques in handling of injections by health workers is still a concern. The adherence to aseptic techniques in handling injections is significantly associated with the nurses to patients ratios. Therefore, it is imperative to improve nurse to patient ratio in public ...

  16. A prospective three-step intervention study to prevent medication errors in drug handling in paediatric care.

    Science.gov (United States)

    Niemann, Dorothee; Bertsche, Astrid; Meyrath, David; Koepf, Ellen D; Traiser, Carolin; Seebald, Katja; Schmitt, Claus P; Hoffmann, Georg F; Haefeli, Walter E; Bertsche, Thilo

    2015-01-01

    To prevent medication errors in drug handling in a paediatric ward. One in five preventable adverse drug events in hospitalised children is caused by medication errors. Errors in drug prescription have been studied frequently, but data regarding drug handling, including drug preparation and administration, are scarce. A three-step intervention study including monitoring procedure was used to detect and prevent medication errors in drug handling. After approval by the ethics committee, pharmacists monitored drug handling by nurses on an 18-bed paediatric ward in a university hospital prior to and following each intervention step. They also conducted a questionnaire survey aimed at identifying knowledge deficits. Each intervention step targeted different causes of errors. The handout mainly addressed knowledge deficits, the training course addressed errors caused by rule violations and slips, and the reference book addressed knowledge-, memory- and rule-based errors. The number of patients who were subjected to at least one medication error in drug handling decreased from 38/43 (88%) to 25/51 (49%) following the third intervention, and the overall frequency of errors decreased from 527 errors in 581 processes (91%) to 116/441 (26%). The issue of the handout reduced medication errors caused by knowledge deficits regarding, for instance, the correct 'volume of solvent for IV drugs' from 49-25%. Paediatric drug handling is prone to errors. A three-step intervention effectively decreased the high frequency of medication errors by addressing the diversity of their causes. Worldwide, nurses are in charge of drug handling, which constitutes an error-prone but often-neglected step in drug therapy. Detection and prevention of errors in daily routine is necessary for a safe and effective drug therapy. Our three-step intervention reduced errors and is suitable to be tested in other wards and settings. © 2014 John Wiley & Sons Ltd.

  17. Containment system of contamination in irradiated materials handling laboratories

    International Nuclear Information System (INIS)

    Lobao, A.S.T.; Araujo, J.A. de; Camilo, R.L.

    1988-01-01

    A study to prevent radiactivity release in lab scale is presented. As a basis for the design all the limits established by the IAEA for ventilation systems were observed. An evaluation of the different parameters involved in the design have been made, resulting in the specification of the working areas, ducts and filtering systems in order to get the best conditions for the safe handling of irradiated materials. (author) [pt

  18. Handling of sodium for the FFTF

    International Nuclear Information System (INIS)

    Ballif, J.L.; Meadows, G.E.

    1978-06-01

    Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10 5 kg (1.7 x 10 6 lbs) of sodium from the tank cars into the reactor vessel and its loop system

  19. Does revealing contextual knowledge of the patient's intention help nurses' handling of nurse calls?

    Science.gov (United States)

    Klemets, Joakim; Toussaint, Pieter

    2016-02-01

    An inherent part of nurses' work is to handle nurse calls that often cause challenging interruptions to ongoing activities. In situations when nurses are interrupted by a nurse call, they need to decide whether to continue focusing on the task at hand or to abort and respond to the nurse call. The difficult decision is often influenced by a number of factors and can have implications for patient safety and quality of care. The study investigates how technology could be designed to support nurses' handling of nurse calls by allowing patients to communicate a more contextualised message revealing their intention to the nurse when issuing a nurse call. Through a qualitative methodology employing a scenario-based design approach, three different nurse call system concepts are evaluated by nurses from different departments of a Norwegian university hospital. Nurses find the uncertainty of not knowing the reason behind a nurse call stressful in situations where they are required to prioritise either the calling patient or a patient they are currently nursing. Providing information about a patient's intention behind a nurse call influences the nurse's decision to various degrees depending on the situation in which they find themselves and the information that is communicated. The nurses' reflections suggested that the message communicated should be designed to contain neither too little nor too much information about the patient's needs. A nurse call system that allows nurses to discern the reason behind a nurse call allows them to make a more accurate decision and relieves stress. In particular, the information communicated would reduce uncertainty and lessen nurses' dependence on other factors in their decision. The design of such a system should, however, carefully consider the needs of the department in which it is deployed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. 18 years experience on UF{sub 6} handling at Japanese nuclear fuel manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    Fujinaga, H.; Yamazaki, N.; Takebe, N. [Japan Nucelar Fuel Conversion Co., Ltd., Ibaraki (Japan)

    1991-12-31

    In the spring of 1991, a leading nuclear fuel manufacturing company in Japan, celebrated its 18th anniversary. Since 1973, the company has produced over 5000 metric ton of ceramic grade UO{sub 2} powder to supply to Japanese fabricators, without major accident/incident and especially with a successful safety record on UF{sub 6} handling. The company`s 18 years experience on nuclear fuel manufacturing reveals that key factors for the safe handling of UF{sub 6} are (1) installing adequate facilities, equipped with safety devices, (2) providing UF{sub 6} handling manuals and executing them strictly, and (3) repeating on and off the job training for operators. In this paper, equipment and the operation mode for UF{sub 6} processing at their facility are discussed.

  1. Structural Design of Systems with Safe Behavior under Single and Multiple Faults

    DEFF Research Database (Denmark)

    Blanke, Mogens; Staroswiecki, Marcel

    2006-01-01

    Handling of multiple simultaneous faults is a complex issue in fault-tolerant control. The design task is particularly made difficult by to the numerous different cases that need be analyzed. Aiming at safe fault-handling, this paper shows how structural analysis can be applied to find...... to structural analysis to disclose which faults could be isolated from a structural point of view using active fault isolation. Results from application on a marine control system illustrate the concepts....... the analytical redundancy relations for all relevant combinations of faults, and can cope with the complexity and size of a real system. Being essential for fault-tolerant control schemes that shall handle particular cases of faults/failures, fault isolation is addressed. The paper introduces an extension...

  2. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Queral, V., E-mail: vicentemanuel.queral@ciemat.es [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Urbon, J. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Garcia, A.; Cuarental, I.; Mota, F. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Micciche, G. [CR ENEA Brasimone, I-40035 Camugnano (BO) (Italy); Ibarra, A. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Rapisarda, D. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Casal, N. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain)

    2011-10-15

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  3. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    International Nuclear Information System (INIS)

    Queral, V.; Urbon, J.; Garcia, A.; Cuarental, I.; Mota, F.; Micciche, G.; Ibarra, A.; Rapisarda, D.; Casal, N.

    2011-01-01

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  4. Health Care Ergonomics: Contributions of Thomas Waters.

    Science.gov (United States)

    Poole Wilson, Tiffany; Davis, Kermit G

    2016-08-01

    The aim of this study was to assess the contributions of Thomas Waters's work in the field of health care ergonomics and beyond. Waters's research of safe patient handling with a focus on reducing musculoskeletal disorders (MSDs) in health care workers contributed to current studies and prevention strategies. He worked with several groups to share his research and assist in developing safe patient handling guidelines and curriculum for nursing students and health care workers. The citations of articles that were published by Waters in health care ergonomics were evaluated for quality and themes of conclusions. Quality was assessed using the Mixed Methods Appraisal Tool and centrality to original research rating. Themes were documented by the type of population the citing articles were investigating. In total, 266 articles that referenced the top seven cited articles were evaluated. More than 95% of them were rated either medium or high quality. The important themes of these citing articles were as follows: (a) Safe patient handling is effective in reducing MSDs in health care workers. (b) Shift work has negative impact on nurses. (c) There is no safe way to manually lift a patient. (d) Nurse curriculums should contain safe patient handling. The research of Waters has contributed significantly to the health care ergonomics and beyond. His work, in combination with other pioneers in the field, has generated multiple initiatives, such as a standard safe patient-handling curriculum and safe patient-handling programs. © 2016, Human Factors and Ergonomics Society.

  5. Technical session 4: Health and safety issues. Working environment control in beryllium handling area

    International Nuclear Information System (INIS)

    Yonehara, K.; Natori, Y.; Tatenuma, K.; Nakamichi, Masaru

    2016-01-01

    Beryllium (Be) and its intermetallic compound (beryllide) are recommended from Japan as the most promising solid neutron multiplier for nuclear fusion power plant. The shape as the neutron multiplier is small sphere (pebble), and the mass production technology of it must be developed urgently. Beryllium is the substance regulated by the law of Ordinance on Prevention of Hazards Due to Specified the Chemical Substances Control. We'll report on a way of the operational environmental management to make a safe Be handling area for the Be handling researchers and workers. (author)

  6. Development and evaluation of online video teaching resources to enhance student knowledge of livestock handling.

    Science.gov (United States)

    Klupiec, C; Pope, S; Taylor, R; Carroll, D; Ward, M H; Celi, P

    2014-07-01

    To evaluate the effectiveness of online audiovisual materials to support the acquisition of animal handling skills by students of veterinary and animal science. A series of video clips (Livestock Handling modules) demonstrating livestock handling procedures was created and delivered online to students enrolled in the Faculty of Veterinary Science, University of Sydney. The effectiveness of these modules for supporting student learning was evaluated via an online survey. The survey also sought feedback on how students could be better prepared for handling livestock. The survey indicated that students found the videos a useful part of their learning experience, particularly by familiarising them with correct handling procedures and emphasising the importance of safety when handling livestock. Students also highlighted that online delivery supported flexible learning. Suggested improvements of the Livestock Handling modules centred around broadening the content of the videos and improving the user-friendliness of online access. Student feedback regarding how the Faculty could better prepare them for livestock handling was dominated by requests for more opportunities to practise animal handling using live animals. The Livestock Handling audiovisual tool is a valuable supplementary resource for developing students' proficiency in safe and effective handling of livestock. However, the results also clearly reveal a perception by students that more hands-on experience is required for acquisition of animal handling skills. These findings will inform future development of the Faculty's animal handling program. © 2014 Australian Veterinary Association.

  7. Monitoring of airborne contamination during the handling of technetium-99m and radioiodine

    International Nuclear Information System (INIS)

    Eadie, A.S.; Horton, P.W.; Hilditch, T.E.

    1980-01-01

    Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99 Tcsup(m) can be safely handled in environments without direct exhaust of the ventilated air but that 125 I and 131 I should always be handled in a ventilated environment such as a fume cupboard or a down-draught work-station of the total-exhaust type. Monitoring of thyroid uptake proves to be the most reliable means of monitoring airborne contamination by these radionuclides, but burdens and radiation doses for typical procedures are well within the maximum permissible limits of the Code of Practice for the Protection of Persons from Ionizing Radiation arising from Medical and Dental Use. (author)

  8. Thermodynamic processes associated with frostbite in the handling of liquid nitrogen

    Science.gov (United States)

    Johnson, W. L.; Cook, C. R.

    2014-01-01

    It is often taught that exposure to liquid nitrogen will cause frostbite or more severe damage to exposed skin tissue. However, it is also demonstrated that a full hand can be briefly immersed in liquid nitrogen without damage. To better understand and possibly visualize the effects of human tissue exposure to liquid nitrogen, a series of tests were conducted using simulated hands and arms composed of molded gelatin forms. The simulated hands and arms were immersed, sprayed, or splashed with liquid nitrogen both with and without state of the art personal protective equipment. Thermocouples were located within the test articles to allow for thermal mapping during the freezing process. The study is aimed to help understand frostbite hazards and the time constants involved with the handling of liquid nitrogen to improve future safety protocols for the safe handling of cryogenic fluids. Results of the testing also show the limits to handling liquid nitrogen while using various means of protection.

  9. Thermodynamic processes associated with frostbite in the handling of liquid nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, W. L. [Cryogenics Test Laboratory, NASA Kennedy Space Center, Kennedy Space Center, FL, 32899 (United States); Cook, C. R. [Dept. Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, 32611 (United States)

    2014-01-29

    It is often taught that exposure to liquid nitrogen will cause frostbite or more severe damage to exposed skin tissue. However, it is also demonstrated that a full hand can be briefly immersed in liquid nitrogen without damage. To better understand and possibly visualize the effects of human tissue exposure to liquid nitrogen, a series of tests were conducted using simulated hands and arms composed of molded gelatin forms. The simulated hands and arms were immersed, sprayed, or splashed with liquid nitrogen both with and without state of the art personal protective equipment. Thermocouples were located within the test articles to allow for thermal mapping during the freezing process. The study is aimed to help understand frostbite hazards and the time constants involved with the handling of liquid nitrogen to improve future safety protocols for the safe handling of cryogenic fluids. Results of the testing also show the limits to handling liquid nitrogen while using various means of protection.

  10. Thermodynamic processes associated with frostbite in the handling of liquid nitrogen

    International Nuclear Information System (INIS)

    Johnson, W. L.; Cook, C. R.

    2014-01-01

    It is often taught that exposure to liquid nitrogen will cause frostbite or more severe damage to exposed skin tissue. However, it is also demonstrated that a full hand can be briefly immersed in liquid nitrogen without damage. To better understand and possibly visualize the effects of human tissue exposure to liquid nitrogen, a series of tests were conducted using simulated hands and arms composed of molded gelatin forms. The simulated hands and arms were immersed, sprayed, or splashed with liquid nitrogen both with and without state of the art personal protective equipment. Thermocouples were located within the test articles to allow for thermal mapping during the freezing process. The study is aimed to help understand frostbite hazards and the time constants involved with the handling of liquid nitrogen to improve future safety protocols for the safe handling of cryogenic fluids. Results of the testing also show the limits to handling liquid nitrogen while using various means of protection

  11. Safe waste management practices in beryllium facilities

    International Nuclear Information System (INIS)

    Bhat, P.N.; Soundararajan, S.; Sharma, D.N.

    2012-01-01

    Beryllium, an element with the atomic symbol Be, atomic number 4, has very high stiffness to weight ratio and low density. It has good electrical conductive properties with low coefficient of thermal expansion. These properties make the metal beryllium very useful in varied technological endeavours, However, beryllium is recognised as one of the most toxic metals. Revelation of toxic effects of beryllium resulted in institution of stringent health and safety practices in beryllium handling facilities. The waste generated in such facilities may contain traces of beryllium. Any such waste should be treated as toxic waste and suitable safe waste management practices should be adopted. By instituting appropriate waste management practice and through a meticulously incorporated safety measures and continuous surveillance exercised in such facilities, total safety can be ensured. This paper broadly discusses health hazards posed by beryllium and safe methods of management of beryllium bearing wastes. (author)

  12. Feeling safe during an inpatient hospitalization: a concept analysis.

    Science.gov (United States)

    Mollon, Deene

    2014-08-01

    This paper aims to explore the critical attributes of the concept feeling safe. The safe delivery of care is a high priority; however; it is not really known what it means to the patient to 'feel safe' during an inpatient hospitalization. This analysis explores the topic of safety from the patient's perspective. Concept analysis. The data bases of CINAHL, Medline, PsychInfo and Google Scholar for the years 1995-2012 were searched using the terms safe and feeling safe. The eight-step concept analysis method of Walker and Avant was used to analyse the concept of feeling safe. Uses and defining attributes, as well as identified antecedents, consequences and empirical referents, are presented. Case examples are provided to assist in the understanding of defining attributes. Feeling safe is defined as an emotional state where perceptions of care contribute to a sense of security and freedom from harm. Four attributes were identified: trust, cared for, presence and knowledge. Relationship, environment and suffering are the antecedents of feeling safe, while control, hope and relaxed or calm are the consequences. Empirical referents and early development of a theory of feeling safe are explored. This analysis begins the work of synthesizing qualitative research already completed around the concept of feeling safe by defining the key attributes of the concept. Support for the importance of developing patient-centred models of care and creating positive environments where patients receive high-quality care and feel safe is provided. © 2014 John Wiley & Sons Ltd.

  13. Handling radioactivity: a practical approach for scientists and engineers

    International Nuclear Information System (INIS)

    Stewart, D.C.

    1981-01-01

    The aim of this book is to present an overall view in a descriptive and essentially nonmathematical way of the practicalities of handling radioactivity. It is hoped that the material will be particularly helpful to those entering the nuclear field for the first time and to those working in related areas whose responsibilities require them to have a general knowledge of the subject of radioactivity handling and its vocabulary. The presentation is primarily for bench-scale operations. There is a considerable emphasis on facilities since these are fundamental to the safe handling of active materials. Facility design and detail is also unfortunately an area where the relevant information is largely scattered through literature sources that are not accessible to most readers. Some of the topics surveyed - such as dosimetry, shielding and nuclear criticality - are extremely complex and no pretense is made that the treatment here represents more than bare bone summaries of the fields. A considerable effort has been made to cite the key references in each area where more detailed information can be found. A few additional useful references not cited directly in the text appear in an abbreviated bibliography at the end of the book

  14. Unique and massive Chernobyl cranes for deconstruction activities in the new safe confinement

    International Nuclear Information System (INIS)

    Parameswaran, N. A. Vijay; Chornyy, Igor; Owen, Rob; Saint Victor, Francois de

    2013-01-01

    On 26 April 1986, the worst nuclear power plant accident in history occurred at the Chernobyl plant in Ukraine (then part of the Soviet Union). The destruction of Unit 4 sent highly radioactive fallout over Belarus, Russia, Ukraine, and Europe. The object shelter-a containment sarcophagus-was built in November 1986 to limit exposure to radiation. However, it has only a planned 25-year lifespan and would probably not survive even a moderate seismic event in a region that has more than its share of such events. It was time to take action. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant Unit. One of the major mechanical handling systems to be installed in the new safe confinement is the Main Cranes System. The planned decontamination and decommissioning or dismantling activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the new safe confinement, will require large and sophisticated cranes. The article will focus on the current progress of the new safe confinement and of the main cranes system for the decommissioning or dismantling activities. (authors)

  15. Unique and massive Chernobyl cranes for deconstruction activities in the new safe confinement

    Energy Technology Data Exchange (ETDEWEB)

    Parameswaran, N. A. Vijay; Chornyy, Igor [Bechtel Systems and Infrastructure, Inc., Chernobyl Project-SIP-PMU, 7/1, Gvardeyskoy div. Str., Kiev Region, Slavutich, 07101 (Ukraine); Owen, Rob [PaR Systems, Inc., 707 Country Road E West, Shoreview, Minnesota 55126-7007 (United States); Saint Victor, Francois de [Bouygues Travaux Publics Challenger, 1, avenue Eugene Freyssinet, Guyancourt, 78601 St-Quentin-en-Yvelines (France)

    2013-07-01

    On 26 April 1986, the worst nuclear power plant accident in history occurred at the Chernobyl plant in Ukraine (then part of the Soviet Union). The destruction of Unit 4 sent highly radioactive fallout over Belarus, Russia, Ukraine, and Europe. The object shelter-a containment sarcophagus-was built in November 1986 to limit exposure to radiation. However, it has only a planned 25-year lifespan and would probably not survive even a moderate seismic event in a region that has more than its share of such events. It was time to take action. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant Unit. One of the major mechanical handling systems to be installed in the new safe confinement is the Main Cranes System. The planned decontamination and decommissioning or dismantling activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the new safe confinement, will require large and sophisticated cranes. The article will focus on the current progress of the new safe confinement and of the main cranes system for the decommissioning or dismantling activities. (authors)

  16. Assessment of dose using TLD during activity handling at RPhL, BRIT

    International Nuclear Information System (INIS)

    Choughule, Nitin V.; Bairwa, S.M.; Murali, S.; Rakesh, R.B.; Madhumita, B.; Adtani, M.M.; Mehra, Kiran; Padmanabhan, D.; Borkute, S.D.; Pal, N.; Sachdev, S.S.

    2012-01-01

    Radiopharmaceutical Lab (RPhL), BRIT undertakes production, supply of radiopharmaceuticals. At RPhL short lived isotopes 131 I, 99 Mo, 99m Tc, 125 I, 153 Sm, 32 P and 51 Cr, are handled with total activity handled per week ranging from MBq to TBq (mCiCi). Radiological survey provides idea on radiation level helps to ensure safe working condition. In order to improve the working condition and to estimate the integrated dose over a period of week with uniform pattern of activity handling in the period, a study was carried out using TLD badges. Specifically prepared TLD badges containing CaSO 4 :Dy phosphor were placed at various locations at RPhL It is used for personnel monitoring. One set of TLD was exposed for a week long period while the other set was exposed only during activity handling, kept in the lead pot during the rest of the period. Dose measured by TLDs were compared with the dose estimated using the survey data for the respective locations as well as with the dose estimated using the activity handled by taking into account the time, distance and shielding. The maximum radiation level recorded during lab survey was used to estimate the TLD exposure during the period. It was observed that results on TLD dose measurement and estimated doses using survey results were of same order. The cumulative TLD dose recorded for week duration (168 h) was significantly higher than doses recorded by exposed TLD only during activity handling (8 h). It was expected that the TLD dose would not be more than dose estimated using radiation survey data, while in 3 among 8 experimental TLDs, the dose was ∼ 25% higher. This could be due to the movement of active material or open handling of activity do not get reflected during normal radiation survey and contribution from background radiation at the lab where those TLDs were placed. The individual dose of all the personnel working in different labs were well within the relevant dose limits indicating the safe working condition

  17. Shielded enclosure for handling radioactive material

    International Nuclear Information System (INIS)

    Laurent, H.; Courouble, J.M.

    1959-01-01

    Two enclosures linked by an air-lock are described: they are designed for the safe handling of 5 curies 0.3 to 0.5 MeV γ emitters, and each is composed of a semi-tight case, ventilated, clad in 80 mm steel plate, and suited for a wide variety of physics and chemistry operations. The equipment required for any given operation can be installed in the shortest possible time, access to the enclosure being via a removable front. Visual control is assured through a lead-glass screen. Each enclosure is fitted with a master-slave manipulator, Argon model 7, and plugs and air-locks are provided for the introduction of liquids and solids. (author) [fr

  18. Percutaneous tracheostomy in patients with cervical spine fractures--feasible and safe.

    Science.gov (United States)

    Ben Nun, Alon; Orlovsky, Michael; Best, Lael Anson

    2006-08-01

    The aim of this study is to evaluate the short and long-term results of percutaneous tracheostomy in patients with documented cervical spine fracture. Between June 2000 and September 2005, 38 consecutive percutaneous tracheostomy procedures were performed on multi-trauma patients with cervical spine fracture. Modified Griggs technique was employed at the bedside in the general intensive care department. Staff thoracic surgeons and anesthesiologists performed all procedures. Demographics, anatomical conditions, presence of co-morbidities and complication rates were recorded. The average operative time was 10 min (6-15). Two patients had minor complications. One patients had minor bleeding (50 cc) and one had mild cellulitis. Nine patients had severe paraparesis or paraplegia prior to the PCT procedure and 29 were without neurological damage. There was no PCT related neurological deterioration. Twenty-eight patients were discharged from the hospital, 21 were decannulated. The average follow-up period was 18 months (1-48). There was no delayed, procedure related, complication. These results demonstrate that percutaneous tracheostomy is feasible and safe in patients with cervical spine fracture with minimal short and long-term morbidity. We believe that percutaneous tracheostomy is the procedure of choice for patients with cervical spine fracture who need prolonged ventilatory support.

  19. Clinicopathological characteristic and clinical handling of the patients with 2 cm or less gastric GISTs.

    Science.gov (United States)

    Kataoka, Mikinori; Kawai, Takashi; Ikemiyagi, Hidekazu; Fujii, Takashi; Fukuzawa, Mari; Fukuzawa, Masakatsu; Kubota, Keisuke; Yoshida, Masashi; Suzuki, Shinji; Kitajima, Masaki

    2013-01-01

    We previously reported that safety and efficacy of mucosal cutting biopsy for diagnosing included 2 cm or less gastric GISTs. However, there have been no reports stating the clinicopathological characteristic and clinical handling of the patients with 2 cm or less gastric GISTs. The aim of our study is to investigate the clinicopathological characteristic and clinical handling of the patients with 2 cm or less gastric GISTs. The 19 patients diagnosed with GIST by mucosal cutting biopsy were divided into 2 groups: Group I; subjects were GISTs with 2 cm or less, Group II; subjects were GISTs >2 cm. We compared the 2 groups in terms of mean age, tumor size, tumor site, histopathological risk grade. In cases that underwent surgery with a diagnosis of GIST, we compared the pre- and postoperative histopathological diagnosis, and the histopathlogical risk grade within each group. The mean age and tumor size were significantly higher in Group I than in Group II. Meanwhile, there were no significant differences between the 2 groups, sex ratio, tumor site. All lesions were at histopathological risk grade at very low risk and low risk respectively. In 17 patients with GIST who underwent surgery, the histopathological diagnoses, immunostaining were in agreement with those from the mucosal cutting biopsy specimens in all cases, but mitotic count of one patient was not in agreement in group II. The 2 cm or less gastric GISTs diagnosed with histpathlogical very low risk can be considered acceptable to follow-up.

  20. Toward Improving Food Safety in the Domestic Environment: A Multi-Item Rasch Scale for the Measurement of the Safety Efficacy of Domestic Food-Handling Practices

    NARCIS (Netherlands)

    Fischer, A.R.H.; Frewer, L.J.; Nauta, M.J.

    2006-01-01

    To reduce consumer health risks from foodborne diseases that result from improper domestic food handling, consumers need to know how to safely handle food. To realize improvements in public health, it is necessary to develop interventions that match the needs of individual consumers. Successful

  1. Solution for remote handling in accelerator installations

    International Nuclear Information System (INIS)

    Burgerjon, J.J.; Ekberg, E.L.; Grisham, D.L.; Horne, R.A.; Meyer, R.E.; Flatau, C.R.; Wilson, K.B.

    1977-01-01

    A description is given of a remote-handling system designed for the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF), versatile enough to be used in a variety of situations found around particle accelerators. The system consists of a bilateral (force-reflecting) servomanipulator installed on an articulated hydraulic boom. The boom also carries the necessary tools and observation devices. The whole slave unit can be moved by crane or truck to the area of operation. A control cable connects the slave unit with the control station, located at a safe distance in a trailer. Various stages of development as well as some operating experience are discussed

  2. Safe Re-use Practices in Wastewater-Irrigated Urban Vegetable Farming in Ghana

    DEFF Research Database (Denmark)

    Keraita, Bernard; Abaidoo, R.C; Beernaerts, I.

    2012-01-01

    of stakeholders at different levels along the food chain. This paper presents an overview of safe re-use practices including farm-based water treatment methods, water application techniques, post-harvest handling practices, and washing methods. The overview is based on a comprehensive analysis of the literature......Irrigation using untreated wastewater poses health risks to farmers and consumers of crop products, especially vegetables. With hardly any wastewater treatment in Ghana, a multiple-barrier approach was adopted and safe re-use practices were developed through action research involving a number...... and our own specific studies, which used data from a broad range of research methods and approaches. Identifying, testing, and assessment of safe practices were done with the active participation of key actors using observations, extensive microbiological laboratory assessments, and field...

  3. Long-term treatment with tenofovir in Asian-American chronic hepatitis B patients is associated with abnormal renal phosphate handling.

    Science.gov (United States)

    Tien, Connie; Xu, Jason J; Chan, Linda S; Chang, Mimi; Lim, Carolina; Lee, Sue; Huh, Brian; Shinada, Shuntaro; Bae, Ho S; Fong, Tse-Ling

    2015-02-01

    Increased risk of defective urinary phosphate reabsorption and osteoporosis has been reported in HIV and chronic hepatitis B (CHB) patients treated with tenofovir disoproxil fumarate (TDF). Goals of this study were to evaluate the prevalence of renal phosphate wasting and abnormal bone mineral density in CHB patients taking TDF compared to CHB patients treated with entecavir (ETV) and untreated CHB patients. This is a cross-sectional study of 146 consecutive Asian-American CHB patients who were treatment naïve (n = 60) or treated with either TDF (n = 42) or ETV (n = 44). Proximal tubular handling of phosphate was assessed by the maximal rate of tubular reabsorption of phosphate (TmPO4) divided by glomerular filtration rate (GFR) (TmPO4/GFR). Bone mineral density (BMD) was measured using dual X-ray absorptiometry. TmPO4/GFR was similar among CHB patients treated with TDF compared to untreated patients and patients taking ETV. However, among patients treated with ≥18 months of TDF or ETV, prevalence of abnormal TmPO4/GFR was higher among patients treated with TDF compared to ETV (48.5 % (16/33) vs. 12.5 % (3/24), p = 0.005). Overall prevalence of osteoporosis in this cohort of CHB patients was 14 %, with no significant difference between the three groups. Renal phosphate handling did not correlate with osteoporosis. Chronic hepatitis B patients treated with ≥18 months of TDF experienced an increased risk of proximal tubular dysfunction. TDF did not increase the risk of osteoporosis. Longitudinal studies are needed to confirm these findings.

  4. An electrical pulse hydride injector (EPHI) for reactor fueling and tritium handling applications

    International Nuclear Information System (INIS)

    Azizov, E.A.; Kareev, Yu.A.; Savotkin, A.N.; Frunze, V.V.; Penzhorn, R.D.; Glugla, M.

    1995-01-01

    An electrical pulse hydride injector (EPHI) has been developed for reactor fuelling as well as for handling of hydrogen isotopes in facilities operating with tritium. Salient features of the EPHI are the accuracy with which the fuelling rate can be controlled and the avoidance of a pressurized ballast. The generator is simple and allows for safe operation with tritium. (orig.)

  5. Electromyography tests in patients with implanted cardiac devices are safe regardless of magnet placement.

    Science.gov (United States)

    Ohira, Masayuki; Silcox, Jade; Haygood, Deavin; Harper-King, Valerie; Alsharabati, Mohammad; Lu, Liang; Morgan, Marla B; Young, Angela M; Claussen, Gwen C; King, Peter H; Oh, Shin J

    2013-01-01

    We compared the problems or complications associated with electrodiagnostic testing in 77 patients with implanted cardiac devices. Thirty tests were performed after magnet placement, and 47 were performed without magnet application. All electrodiagnostic tests were performed safely in all patients without any serious effect on the implanted cardiac devices with or without magnet placement. A significantly higher number of patient symptoms and procedure changes were reported in the magnet group (P magnet group patients had an approximately 11-fold greater risk of symptoms than those in the control group. Our data do not support a recommendation that magnet placement is necessary for routine electrodiagnostic testing in patients with implanted cardiac devices, as long as our general and specific guidelines are followed. Copyright © 2012 Wiley Periodicals, Inc.

  6. Percutaneous Revision of a Testicular Prosthesis is Safe, Cost-effective, and Provides Good Patient Satisfaction

    Directory of Open Access Journals (Sweden)

    Eugene B. Cone

    2015-09-01

    Full Text Available Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.

  7. Limited Blood Transfusions Are Safe in Orthopaedic Trauma Patients.

    Science.gov (United States)

    Dolenc, Andrea J; Morris, William Z; Como, John J; Wagner, Karl G; Vallier, Heather A

    2016-12-01

    Controversy exists over association of blood transfusions with complications. The purpose was to assess effects of limited transfusions on complication rates and hospital course. Level 1 trauma center. Three hundred seventy-one consecutive patients with Injury Severity Score ≥16 underwent fixation of fractures of spine (n = 111), pelvis (n = 72), acetabulum (n = 57), and/or femur (n = 179). Those receiving >3 units of packed red blood cell were excluded. Fracture type, associated injuries, treatment details, ventilation time, complications, and hospital stay were prospectively recorded. Ninety-eight patients with 107 fractures received limited transfusion, and 119 patients with 123 fractures were not transfused. The groups did not differ in age, fracture types, time to fixation, or associated injuries. Lowest hematocrit was lower in the transfused group (22.8 vs. 30.0, P < 0.0001). Surgical duration (3:23 vs. 2:28) and estimated blood loss (462 vs. 211 mL) were higher in transfused patients (all P < 0.003). Pulmonary complications occurred in 12% of transfused and 4% of nontransfused, (P = 0.10). Mean days of mechanical ventilation (2.51 vs. 0.45), intensive care unit days (4.5 vs. 1.5) and total hospital stay (8.8 vs. 5.7) were higher in transfused patients (all P ≤ 0.006). After multivariate analysis, limited transfusion was associated with increased hospital and intensive care unit stays and mechanical ventilation time, but not with complications. Patients receiving ≤3 units of packed red blood cell had lower hematocrit and greater surgical burden, but no difference in complications versus the nontransfused group. Limited blood transfusions are likely safe, excepting a possible association with longer mechanical ventilation times and hospital stays. Therapeutic level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Is selective internal radioembolization safe and effective for patients with inoperable hepatocellular carcinoma and venous thrombosis?

    Science.gov (United States)

    Woodall, Charles E; Scoggins, Charles R; Ellis, Susan F; Tatum, Clifton M; Hahl, Michael J; Ravindra, Kadiyala V; McMasters, Kelly M; Martin, Robert C G

    2009-03-01

    The goal of this study was to examine the safety and efficacy of selective internal radioembolization (SIR) for hepatocellular carcinoma (HCC) with portal vein or caval thrombosis (VT), or both. Recent reports have demonstrated that SIR is safe for patients with HCC, but the impact on efficacy of venous thrombosis is unknown. Prospective single-arm study of the use of Therasphere in patients with unresectable HCC enrolled from January 2004 to June 2007. Patients were categorized into three groups based on VT status and therapy. Fifty-two patients were enrolled: 20 patients without VT who received SIR, 15 patients with VT who were treated, and 17 patients (10 with VT) who were not treated because of preprocedure screening failure. Fifty-eight treatments were administered, with a median of two treatments per patient (range of one to three treatments). Child's score was different between groups. Of the VT patients treated, 67% had portal VT, 7% had cava VT, and 26% had both. There were no treatment-related deaths. There was no difference in complications among groups (p = 0.34). Treated patients without thrombosis had a median overall survival of 13.9 months versus 2.7 months for those treated with thrombosis and 5.2 months for the untreated group given best supportive care only (p = 0.01). SIR is safe in patients with HCC. Although SIR can be delivered with minimal morbidity, there might be no benefit for patients with VT. Continued emphasis on multimodality therapy in this population is needed to improve survival.

  9. Transportation system (TRUPACT) for contact-handled transuranic wastes

    International Nuclear Information System (INIS)

    Romesberg, L.E.; Pope, R.B.; Burgoyne, R.M.

    1982-04-01

    Contact-handled transuranic defense waste is being, and will continue to be, moved between a number of locations in the United States. The DOE is sponsoring development of safe, efficient, licensable, and cost-effective transportation systems to handle this waste. The systems being developed have been named TRUPACT which stands for TRansUranic PACkage Transporter. The system will be compatible with Type A packagings used by waste generators, interim storage facilities, and repositories. TRUPACT is required to be a Type B packaging since larger than Type A quantities of some radionuclides (particularly plutonium) may be involved in the collection of Type A packagings. TRUPACT must provide structural and thermal protection to the waste in hypothetical accident environments specified in DOT regulations 49CFR173 and NRC regulations 10CFR71. Preliminary design of the systems has been completed and final design for a truck system is underway. The status of the development program is reviewed in this paper and the reference design is described. Tests that have been conducted are discussed and long-term program objectives are reviewed

  10. Observation of High School Students' Food Handling Behaviors: Do They Improve following a Food Safety Education Intervention?

    Science.gov (United States)

    Diplock, Kenneth J; Dubin, Joel A; Leatherdale, Scott T; Hammond, David; Jones-Bitton, Andria; Majowicz, Shannon E

    2018-06-01

    Youth are a key audience for food safety education. They often engage in risky food handling behaviors, prepare food for others, and have limited experience and knowledge of safe food handling practices. Our goal was to investigate the effectiveness of an existing food handler training program for improving safe food handling behaviors among high school students in Ontario, Canada. However, because no schools agreed to provide control groups, we evaluated whether behaviors changed following delivery of the intervention program and whether changes were sustained over the school term. We measured 32 food safety behaviors, before the intervention and at 2-week and 3-month follow-up evaluations by in-person observations of students ( n = 119) enrolled in grade 10 and 12 Food and Nutrition classes ( n = 8) and who individually prepared recipes. We examined within-student changes in behaviors across the three time points, using mixed effects regression models to model trends in the total food handling score (of a possible 32 behaviors) and subscores for "clean" (17 behaviors), "separate" (14 behaviors), and "cook" (1 behavior), adjusting for student characteristics. At baseline, students ( n = 108) averaged 49.1% (15.7 of 32 behaviors; standard deviation = 5.8) correct food handling behaviors, and only 5.5% (6) of the 108 students used a food thermometer to check the doneness of the chicken (the "cook" behavior). All four behavior score types increased significantly ∼2 weeks postintervention and remained unchanged ∼3 months later. Student characteristics (e.g., having taken a prior food handling course) were not significant predictors of the total number of correctly performed food handling behaviors or of the "clean" or "separate" behaviors, working or volunteering in a food service establishment was the only characteristic significantly associated with food thermometer use (i.e., "cook"). Despite the significant increase in correct behaviors, students continued to

  11. A cross-sectional study to assess inhalation device handling and patient satisfaction in COPD

    Directory of Open Access Journals (Sweden)

    Miravitlles M

    2016-02-01

    Full Text Available Marc Miravitlles,1 Jéssica Montero-Caballero,2 Frank Richard,2 Salud Santos,3 Juan Luis Garcia-Rivero,4 Francisco Ortega,5 Xavier Ribera61Pneumology Department, Hospital Universitari Vall d’Hebron, Ciber de Enfermedades Respiratorias (CIBERES, Barcelona, Spain; 2Boehringer Ingelheim Pharma GmbH & Co KG, Ingelheim, Germany; 3Pulmonology Department, Hospital Universitari de Bellvitge, IDIBELL, Universitat de Barcelona, Ciber de Enfermedades Respiratorias (CIBERES, Barcelona, Spain; 4Pneumology Department, Hospital de Laredo, Cantabria, Spain; 5Pneumology Department, Hospital Virgen del Rocío, Sevilla, Spain; 6Boehringer Ingelheim Pharma GmbH & Co KG, Barcelona, Spain Abstract: Delivery of inhaled medications via an inhaler device underpins the effectiveness of treatment for patients with chronic obstructive pulmonary disease (COPD. Correct inhaler technique among patients is also a predictor of achieving treatment compliance and adherence. Reporting of patient satisfaction with inhalers is therefore gaining increasing attention and is now recognized as an important patient-reported outcome in clinical trials involving patients with COPD or asthma. In this cross-sectional study, we use the validated Patient Satisfaction and Preference Questionnaire (PASAPQ to assess the handling and satisfaction for Respimat® Soft Mist™ Inhaler (SMI compared with the Breezhaler® dry powder inhaler (DPI among patients with COPD in Spain. Patients were already assigned to therapy with either SPIRIVA® (tiotropium Respimat® or with Hirobriz®/Onbrez®/Oslif® (indacaterol Breezhaler® for at least 3 but not more than 6 months before completing the PASAPQ at a single visit to the study site. The primary endpoint of the trial was the mean total PASAPQ score. Secondary endpoints were the performance score domain of the PASAPQ, the convenience score domain of the PASAPQ, and the overall satisfaction score of the PASAPQ. For the primary endpoint, the mean PASAPQ

  12. Moving and handling education in the community: technological innovations to improve practice.

    Science.gov (United States)

    Wanless, Stephen; Page, Andrea

    2009-12-01

    Efforts to reduce injuries associated with patient handling are often based on tradition and personal experience rather than sound educational theory. The purpose of this article is to summarize current evidence for educational interventions designed to reduce primary care staff injuries: a significant problem for decades. Evidence suggests that the current 'classroom' teaching of moving and handling is ineffective. There is a growing body of evidence to support newer interventions that are effective or show promise in reducing musculoskeletal injuries in health professionals (Freitag et al, 2007). The authors discuss potential solutions through moving and handling-related motion capture simulation and the use of e-learning to promote an understanding of the principles associated with patient handling tasks.

  13. Safety and availability of the fuel handling system at Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Santaliz, Jorge O.; Paredes, Juan A.

    1998-01-01

    The paper attempts the Fuel Handling (F/H) System maintenance and operating methodology at the Embalse Power Station. It doesn't refer to the F/H process, because it's common and well known by all the CANDU Stations. Instead of that, the presentation will be focused on people qualification, training and selection. Also the key subjects for a smooth and successful operation. Additionally will be remarked the human aspect and the role of the person in the organization. The safe and reliable operation of the CNE Fuel Handling System has been always target, supported by the operational experience. The accountability and fitness for the job were the main qualification for the crew members. They have very clear their role and the importance of equipment which they are operating or manipulating. The person who has greater experience and responsibility must struggle continuously to keep the safe and confident operation. Also we have to increase permanently our knowledge with a greater training and experience exchange with another CANDU 6 Station, like this Conference which let us to grow as persons and technicians. It also allows our utility to have access to other realities and work methods. (authors)

  14. 836: Developing a Cooperative Communication System for Safe, Effective, and Efficient Patient Care

    Science.gov (United States)

    2014-01-01

    cally ill patients (pts) for hemodynamic monitoring using novel VPS’s can be performed efficiently and safely. Methods: In an adult academic medical...for hemodynamic monitoring was selected. Open ended PICCs were inserted using a novel Dop- pler and intravascular EKG positioning system and CXR was...unclear responsibility for task comple- tion; time spent tracking down in-process items like meds and labs; reliance on nurses to track and fix

  15. Plain Radiography May Be Safely Omitted for Selected Major Trauma Patients Undergoing Whole Body CT: Database Study

    Directory of Open Access Journals (Sweden)

    Sarah Hudson

    2012-01-01

    Full Text Available Introduction. Whole body CT is being used increasingly in the primary survey of major trauma patients. We evaluated whether omitting plain films of the chest and pelvis in the primary survey was safe. We compared the probability of survival of patients and time to CT who had plain X-rays to those who did not. Method. We performed a database study on major trauma patients admitted between 2008 and 2010 using data from Trauma, Audit and Research Network (TARN and our PACS system. We included adult major trauma patients who has an ISS of greater than 15 and underwent whole body CT. Results. 245 patients were included in the study. 44 (17.9% did not undergo plain films. The median time to whole body CT from the time of admission was longer (47 minutes in patients having plain films, than those who did not have plain films performed (30 minutes, P<0.005. Mortality was increased in the group who received plain films, 9.5% compared to 4.5%, but this was not statistically significant (P=0.77. Conclusion. We conclude that plain films may be safely omitted during the primary survey of selected major trauma patients.

  16. D-dimer testing for safe exclusion and risk stratification in patients with acute pulmonary embolism in primary care

    Directory of Open Access Journals (Sweden)

    Zhou Yin

    2015-01-01

    Full Text Available Background: Safe exclusion and risk stratification are currently recommended for the initial management of patients with acute pulmonary embolism (APE. The aim of this study was to assess the safe exclusion and risk stratification value of D-dimer (DD for APE when tested at the beginning of admission. Materials and Methods: All consecutive Chinese APE patients and controls were recruited from January 2010 to December 2012. All measurements of serum indexes were made in duplicate and blinded to the patients′ status. All the 40 patients with the first episode of APE were confirmed by multi-detector computed tomographic pulmonary angiography. The plasma prothrombin time (PT, activated partial thromboplastin time, thrombin time, fibrinogen, and DD levels were measured within 24 h of admission. We used the Mann-Whitney U-test to determine the differences between groups and drew receiver operator characteristic curve to evaluate the indexes′ value in the APE screening. Results: The PT and DD in the APE group were significantly higher than those in the disease control group (P 1820 μg/L as cut-off value, the sensitivity, specificity, positive and negative predictive value was 82.5%, 75.2%, 56.9%, and 91.6%, respectively. Conclusion: The patients with APE showed significant higher DD levels compared with disease controls, suggesting a negative qualitative DD test result can safely and efficiently exclude APE in primary care.

  17. Prognostic study of cardiac events in Japanese high risk hemodialysis patients using I-BMIPP-SPECT: B-SAFE study design.

    Science.gov (United States)

    Hasebe, Naoyuki; Moroi, Masao; Nishimura, Masato; Hara, Kazuhiro; Hase, Hiroki; Hashimoto, Akiyoshi; Kumita, Shinichiro; Haze, Kazuo; Momose, Mitsuru; Nagai, Yoji; Sugimoto, Tokuichiro; Kusano, Eiji; Akiba, Takashi; Nakata, Tomoaki; Nishimura, Tsunehiko; Tamaki, Nagara; Kikuchi, Kenjiro

    2008-12-01

    Cardiovascular disease is the leading cause of morbidity and mortality in patients undergoing hemodialysis. Such patients frequently develop complications such as asymptomatic coronary artery disease (CAD). Accordingly, CAD must ideally be diagnosed at an early stage to improve prognosis. Although myocardial perfusion single photon emission computed tomography (SPECT) is valuable for diagnosing CAD, the stress test is not always applicable to patients on hemodialysis. Thus, we proposed a multicenter, prospective cohort study called "B-SAFE" to investigate the applicability of resting (123)I-labeled beta-methyl-iodophenylpentadecanoic acid ((123)I-BMIPP)-SPECT will be used to diagnose cardiac disease and evaluate the prognosis of hemodialysis patients by imaging myocardial fatty acid metabolism. B-SAFE began enrolling patients from June 2006 at 48 facilities. We performed (123)I-BMIPP-SPECT on 702 hemodialysis patients with risk factors for CAD until 30 November 2007 and plan to follow up for three years. The primary endpoints will be cardiac death and sudden death. This study should end in 2010.

  18. Evaluation of ceiling lifts: transfer time, patient comfort and staff perceptions.

    Science.gov (United States)

    Alamgir, Hasanat; Li, Olivia Wei; Yu, Shicheng; Gorman, Erin; Fast, Catherine; Kidd, Catherine

    2009-09-01

    Mechanical lifting devices have been developed to reduce healthcare worker injuries related to patient handling. The purpose of this study was to evaluate ceiling lifts in comparison to floor lifts based on transfer time, patient comfort and staff perceptions in three long-term care facilities with varying ceiling lift coverage. The time required to transfer or reposition patients along with patient comfort levels were recorded for 119 transfers. Transfers performed with ceiling lifts required on average less time (bed to chair transfers: 156.9 seconds for ceiling lift, 273.6 seconds for floor lift) and were found to be more comfortable for patients. In the three facilities, 143 healthcare workers were surveyed on their perceptions of patient handling tasks and equipment. For both transferring and repositioning tasks, staff preferred to use ceiling lifts and also found them to be less physically demanding. Further investigation is needed on repositioning tasks to ensure safe practice.

  19. Handle with care

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1965-03-15

    Full text: A film dealing with transport of radioactive materials by everyday means - rail, road, sea and air transport - has been made for IAEA. It illustrates in broad terms some of the simple precautions which should be followed by persons dealing with such materials during shipment. Throughout, the picture stresses the transport regulations drawn up and recommended by the Agency, and in particular the need to carry out carefully the instructions based on these regulations in order to ensure that there is no hazard to the public nor to those who handle radioactive materials in transit and storage. In straightforward language, the film addresses the porter of a goods wagon, an airline cargo clerk, a dockside crane operator, a truck driver and others who load and ship freight. It shows the various types of package used to contain different categories of radioactive substances according to the intensity of the radiation emitted. It also illustrates their robustness by a series of tests involving drops, fires, impact, crushing, etc. Clear instructions are conveyed on what to do in the event of an unlikely accident with any type of package. The film is entitled, 'The Safe Transport of Radioactive Materials', and is No. 3 in the series entitled, 'Handle with Care'. It was made for IAEA through the United Kingdom Atomic Energy Authority by the Film Producers' Guild in the United Kingdom. It is in 16 mm colour, optical sound, with a running time of 20 minutes. It is available for order at $50 either direct from IAEA or through any of its Member Governments. Prints can be supplied in English, French, Russian or Spanish. Copies are also available for adaptation for commentaries in other languages. (author)

  20. Safe handling of kilogram amounts of fuel-grade plutonium and of gram amounts of plutonium-238, americium-241 and curium-244

    International Nuclear Information System (INIS)

    Louwrier, K.P.; Richter, K.

    1976-01-01

    During the past 10 years about 600 glove-boxes have been installed at the Institute for Transuranium Elements at Karlsruhe. About 80% of these glove-boxes have been designed and equipped for handling 100-g to 1-kg amounts of 239 Pu containing 8-12% 240 Pu (low-exposure plutonium). A small proportion of the glove-boxes is equipped with additional shielding in the form of lead sheet or lead glass for work with recycled plutonium. In these glove-boxes gram-amounts of 241 Am have also been handled for preparation of Al-Am targets using tongs and additional shielding inside the glove-boxes themselves. Water- and lead-shielded glove-boxes equipped with telemanipulators have been installed for routine work with gram-amounts of 241 Am, 243 Am and 244 Cm. A prediction of the expected radiation dose for the personnel is difficult and only valid for a preparation procedure with well-defined preparation steps, owing to the fact that gamma dose-rates depend strongly upon proximity and source seize. Gamma radiation dose measurements during non-routine work for 241 Am target preparation showed that handling of gram amounts leads to a rather high irradiation dose for the personnel, despite lead or steel glove-box shielding and shielding within the glove-boxes. A direct glove-hand to americium contact must be avoided. For all glove-handling of materials with gamma radiation an irradiation control of the forearms of the personnel by, for example, thermoluminescence dosimeters is necessary. Routine handling of americium and curium should be executed with master-slave equipment behind neutron and gamma shielding. (author)

  1. Method for making a low density polyethylene waste form for safe disposal of low level radioactive material

    Science.gov (United States)

    Colombo, P.; Kalb, P.D.

    1984-06-05

    In the method of the invention low density polyethylene pellets are mixed in a predetermined ratio with radioactive particulate material, then the mixture is fed through a screw-type extruder that melts the low density polyethylene under a predetermined pressure and temperature to form a homogeneous matrix that is extruded and separated into solid monolithic waste forms. The solid waste forms are adapted to be safely handled, stored for a short time, and safely disposed of in approved depositories.

  2. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  3. Handling, conditioning and disposal of spent sealed sources

    International Nuclear Information System (INIS)

    1990-02-01

    The series entitled ''Technical Manual for the Management of Low and Intermediate Level Wastes Generated at Small Nuclear Research Centres and by Radioisotope Users in Medicine, Research and Industry'' will serve as reference material to experts on technical assistance missions and provide ''direct know-how'' for technical staff in developing countries. This document is the first in the series. It provides the technical guidance and know-how necessary to permit developing Member States to safely handle, condition and store spent sealed radiation sources. It covers: characterization of sealed sources, legislation and regulations, management of spent sealed sources, transportation and disposal of spent sealed sources. 5 refs, 10 figs, 6 tabs

  4. [Prevention of adverse effects in latex allergic patients: organizing a latex safe operating theatre].

    Science.gov (United States)

    Bonalumi, Sabrina; Barbonaglia, Patrizia; Bertocchi, Carmen

    2006-01-01

    In 2001 the General Health Direction of Region Lombardia approved (decree n. 22303) a guideline for the prevention of latex allergic reactions in patients and health care workers. This document provides general recommendations in order to standardize behaviors in regional health care facilities. The reason is due to a rise in the incident of reactions to latex products in the last 20 years. Nowadays the prevalence is higher in certain risk groups (subjected to frequent and repeated exposures) rather than the general population. The aim of the project was to organize a latex safe operating theatre in the Ospedale Maggiore Policlinico, Mangiagalli e Regina Elena of Milan (Fondazione) and to standardize behaviors in order to prevent adverse effects in latex allergic patients. Thanks to the literature review and the creation of a multidisciplinar team, we produced a protocol. Therefore, we requested manufacturers the certification of the latex content of their products. Results and conclusion. When latex allergic patients need to undergone surgery in our hospital, a latex safe operating theatre is organized by personnel following a multidisciplinar protocol. No allergic reactions were experienced during surgical procedures after the creation of an environment as free as possible from latex contamination. The project will involve an emergency room, one room or more of a ward and of the outpatients department.

  5. Safe management of waste from health-care activities

    International Nuclear Information System (INIS)

    Pruess, A.; Giroult, E.; Rushbrook, P.

    1999-01-01

    The waste produced in the course of health-care activities, from contaminated needles to radioactive isotopes, carries a greater potential for causing infection and injury than any other type of waste, and inadequate or inappropriate management is likely to have serious public health consequences and deleterious effects on the environment. This handbook - the result of extensive international consultation and collaboration - provides comprehensive guidance on safe, efficient, and environmentally sound methods for the handling and disposal of health-care wastes. The various categories of waste are clearly defined and the particular hazards that each poses are described. Considerable prominence is given to the careful planning that is essential for the success of waste management; workable means of minimizing waste production are outlined and the role of reuse and recycling of waste is discussed. Most of the text, however, is devoted to the collection, segregation, storage, transport, and disposal of wastes. Details of containers for each category of waste, labelling of waste packages, and storage conditions are provided, and the various technologies for treatment of waste and disposal of final residues are discussed at length. Advice is given on occupational safety for all personnel involved with waste handling, and a separate chapter is devoted to the closely related topic of hospital hygiene and infection control. The handbook pays particular attention to basic processes and technologies that are not only safe but also affordable, sustainable, and culturally appropriate. For health-care settings in which resources are severely limited there is a separate chapter on minimal programmes; this summarizes all the simplest and least costly techniques that can be employed for the safe management of health-care wastes. The guide is aimed at public health managers and policy-makers, hospital managers, environmental health professionals, and all administrators with an

  6. Advanced operator interface design for CANDU-3 fuel handling system

    Energy Technology Data Exchange (ETDEWEB)

    Arapakota, D [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1996-12-31

    The Operator Interface for the CANDU 3 Fuel Handling (F/H) System incorporates several improvements over the existing designs. A functionally independent sit-down CRT (cathode-ray tube) based Control Console is provided for the Fuel Handling Operator in the Main Control Room. The Display System makes use of current technology and provides a user friendly operator interface. Regular and emergency control operations can be carried out from this control console. A stand-up control panel is provided as a back-up with limited functionality adequate to put the F/H System in a safe state in case of an unlikely non-availability of the Plant Display System or the F/H Control System`. The system design philosophy, hardware configuration and the advanced display system features are described in this paper The F/H Operator Interface System developed for CANDU 3 can be adapted to CANDU 9 as well as to the existing stations. (author).

  7. Advanced operator interface design for CANDU-3 fuel handling system

    International Nuclear Information System (INIS)

    Arapakota, D.

    1995-01-01

    The Operator Interface for the CANDU 3 Fuel Handling (F/H) System incorporates several improvements over the existing designs. A functionally independent sit-down CRT (cathode-ray tube) based Control Console is provided for the Fuel Handling Operator in the Main Control Room. The Display System makes use of current technology and provides a user friendly operator interface. Regular and emergency control operations can be carried out from this control console. A stand-up control panel is provided as a back-up with limited functionality adequate to put the F/H System in a safe state in case of an unlikely non-availability of the Plant Display System or the F/H Control System'. The system design philosophy, hardware configuration and the advanced display system features are described in this paper The F/H Operator Interface System developed for CANDU 3 can be adapted to CANDU 9 as well as to the existing stations. (author)

  8. Canadian capabilities in fusion fuels technology and remote handling

    International Nuclear Information System (INIS)

    1987-10-01

    This report describes Canadian expertise in fusion fuels technology and remote handling. The Canadian Fusion Fuels Technology Project (CFFTP) was established and is funded by the Canadian government, the province of Ontario and Ontario Hydro to focus on the technology necessary to produce and manage the tritium and deuterium fuels to be used in fusion power reactors. Its activities are divided amongst three responsibility areas, namely, the development of blanket, first wall, reactor exhaust and fuel processing systems, the development of safe and reliable operating procedures for fusion facilities, and, finally, the application of these developments to specific projects such as tritium laboratories. CFFTP also hopes to utilize and adapt Canadian developments in an international sense, by, for instance, offering training courses to the international tritium community. Tritium management expertise is widely available in Canada because tritium is a byproduct of the routine operation of CANDU reactors. Expertise in remote handling is another byproduct of research and development of of CANDU facilities. In addition to describing the remote handling technology developed in Canada, this report contains a brief description of the Canadian tritium laboratories, storage beds and extraction plants as well as a discussion of tritium monitors and equipment developed in support of the CANDU reactor and fusion programs. Appendix A lists Canadian manufacturers of tritium equipment and Appendix B describes some of the projects performed by CFFTP for offshore clients

  9. Regulatory control for safe usage of radiation sources in India

    International Nuclear Information System (INIS)

    Ghosh, P.K.; Sonawane, A.U.

    1998-01-01

    The widespread applications of radioactive materials and radiation generating equipment in the field of industry, medicine agriculture and research in India necessitated the establishment of an efficient regulatory framework and consequently the Atomic Energy Regulatory Board (AERB) was constituted to exercise regulatory control over the safe usage of the radioactive materials and the radiation generating equipment. The Atomic Energy Act, 1962 and the Radiation Protection Rules, 1971 promulgated under the Act forms the basis of radiation safety in India and Chairman, AERB is the Competent Authority to enforce the regulatory provisions of the Radiation Protection Rules, 1971, for safe use of radiation source in the country. AERB has published a number of documents such as Radiation Surveillance Procedures, Standards, Codes, Guides and Manuals for safe use and handling of radioactive materials and radiation generating equipment. Apart from nuclear fuel cycle documents, these publications pertain to industrial radiography, medical application of radiation, transport of radioactive material, industrial gamma irradiators, X-ray units etc. AERB safety related publications are based on international standards e.g. BSS, IAEA, ICRP, ISO etc. This paper outlines the methodology of regulatory control exercised by AERB for safe use of the radioactive materials and the radiation generating equipment in the country. (author)

  10. The Effect of Immunologically Safe Plasma Rich in Growth Factor Eye Drops in Patients with Sjögren Syndrome.

    Science.gov (United States)

    Sanchez-Avila, Ronald Mauricio; Merayo-Lloves, Jesus; Riestra, Ana Cristina; Anitua, Eduardo; Muruzabal, Francisco; Orive, Gorka; Fernández-Vega, Luis

    2017-06-01

    The objective was to provide preliminary information about the efficacy and safety of immunologically safe plasma rich in growth factor (immunosafe PRGF) eye drops in the treatment of moderate to severe dry eye in patients with primary and secondary Sjögren's syndrome (SS) and to analyze the influence of several variables on treatment outcomes. This retrospective study included patients with SS. All patients were treated with previously immunosafe PRGF eye drops to reduce the immunologic component contents. Ocular Surface Disease Index (OSDI) scale, best-corrected visual acuity (BCVA), visual analog scale (VAS) frequency, and VAS severity outcome measures were evaluated before and after treatment with immunosafe PRGF. The potential influence of some patient clinical variables on results was also assessed. Safety assessment was also performed reporting all adverse events. Twenty-six patients (12 patients with primary SS, and 14 patients suffering secondary SS) with a total of 52 affected eyes were included and evaluated. Immunosafe PRGF treatment showed a significant reduction (P PRGF with corticosteroids. Only 2 adverse events were reported in 2 patients (7.7% of patients). Signs and symptoms of dry eye syndrome in patients with SS were reduced after treatment with PRGF-Endoret eye drops. Immunosafe PRGF-Endoret is safe and effective for treating patients with primary and secondary SS.

  11. 78 FR 27303 - Irradiation in the Production, Processing, and Handling of Animal Feed and Pet Food; Electron...

    Science.gov (United States)

    2013-05-10

    ...-0178] Irradiation in the Production, Processing, and Handling of Animal Feed and Pet Food; Electron... electron beam and x-ray sources for irradiation of poultry feed and poultry feed ingredients. This action... CFR part 579) to provide for the safe use of electron beam and x-ray sources for irradiation of...

  12. Handling of multiassembly sealed baskets between reactor storage and a remote handling facility

    International Nuclear Information System (INIS)

    Massey, J.V.; Kessler, J.H.; McSherry, A.J.

    1989-06-01

    The storage of multiple fuel assemblies in sealed (welded) dry storage baskets is gaining increasing use to augment at-reactor fuel storage capacity. Since this increasing use will place a significant number of such baskets on reactor sites, some initial downstream planning for their future handling scenarios for retrieving multi-assembly sealed baskets (MSBs) from onsite storage and transferring and shipping the fuel (and/or the baskets) to a federally operated remote handling facility (RHF). Numerous options or at-reactor and away-from-reactor handling were investigated. Materials handling flowsheets were developed along with conceptual designs for the equipment and tools required to handle and open the MSBs. The handling options were evaluated and compared to a reference case, fuel handling sequence (i.e., fuel assemblies are taken from the fuel pool, shipped to a receiving and handling facility and placed into interim storage). The main parameters analyzed are throughout, radiation dose burden and cost. In addition to evaluating the handling of MSBs, this work also evaluated handling consolidated fuel canisters (CFCs). In summary, the handling of MSBs and CFCs in the store, ship and bury fuel cycle was found to be feasible and, under some conditions, to offer significant benefits in terms of throughput, cost and safety. 14 refs., 20 figs., 24 tabs

  13. Safety improvement of start-up neutron source handling work by preparing new transport containers

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Sawahata, Hiroaki; Yanagida, Yoshinori; Shinohara, Masanori; Kawamoto, Taiki; Takada, Shoji

    2016-01-01

    The conventional transport containers that have been used in HTTR start-up neutron source replacement work are not specialized type for HTTR start-up neutron source. As the risks associated with the safe handling of neutron source holders due to the above fact, the following three risks have been confirmed: (1) exposure risk due to leakage of neutron source or gamma rays, (2) risk of erroneous fall of neutron source holders, and (3) accident due to incorrect handling of transport containers. This paper reports the risks confirmed in the handling of neutron source holders associated with transport containers and the risk reduction measures, as well as the fabrication of new transport containers. By employing the size-reduction and simple structure, new transport containers have been completed at the same level of costs compared with the continuous use of the conventional transport containers, while satisfying the criteria of Type A transport materials and serving as risk preventive measures. Thus, new transport containers aimed at the risk prevention measures for the handling work of neutron source holders have been completed, and the safety of operation has been improved. (A.O.)

  14. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Demanes, D. Jeffrey; Martinez, Alvaro A.; Ghilezan, Michel; Hill, Dennis R.; Schour, Lionel; Brandt, David; Gustafson, Gary

    2011-01-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography–defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis–free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  15. Handling encapsulated spent fuel in a geologic repository environment

    International Nuclear Information System (INIS)

    Ballou, L.B.

    1983-02-01

    In support of the Spent Fuel Test-Climate at the U.S. Department of Energy's Nevada Test Site, a spent-fuel canister handling system has been designed, deployed, and operated successfully during the past five years. This system transports encapsulated commercial spent-fuel assemblies between the packaging facility and the test site (approx. 100 km), transfers the canisters 420 m vertically to and from a geologic storage drift, and emplaces or retrieves the canisters from the storage holes in the floor of the drift. The spent-fuel canisters are maintained in a fully shielded configuration at all times during the handling cycle, permitting manned access at any time for response to any abnormal conditions. All normal operations are conducted by remote control, thus assuring as low as reasonably achievable exposures to operators; specifically, we have had no measurable exposure during 30 canister transfer operations. While not intended to be prototypical of repository handling operations, the system embodies a number of concepts, now demonstrated to be safe, reliable, and economical, which may be very useful in evaluating full-scale repository handling alternatives in the future. Among the potentially significant concepts are: Use of an integral shielding plug to minimize radiation streaming at all transfer interfaces. Hydraulically actuated transfer cask jacking and rotation features to reduce excavation headroom requirements. Use of a dedicated small diameter (0.5 m) drilled shaft for transfer between the surface and repository workings. A wire-line hoisting system with positive emergency braking device which travels with the load. Remotely activated grapples - three used in the system - which are insensitive to load orientation. Rail-mounted underground transfer vehicle operated with no personnel underground

  16. Nuclear fuel handling apparatus

    International Nuclear Information System (INIS)

    Andrea, C.; Dupen, C.F.G.; Noyes, R.C.

    1977-01-01

    A fuel handling machine for a liquid metal cooled nuclear reactor in which a retractable handling tube and gripper are lowered into the reactor to withdraw a spent fuel assembly into the handling tube. The handling tube containing the fuel assembly immersed in liquid sodium is then withdrawn completely from the reactor into the outer barrel of the handling machine. The machine is then used to transport the spent fuel assembly directly to a remotely located decay tank. The fuel handling machine includes a decay heat removal system which continuously removes heat from the interior of the handling tube and which is capable of operating at its full cooling capacity at all times. The handling tube is supported in the machine from an articulated joint which enables it to readily align itself with the correct position in the core. An emergency sodium supply is carried directly by the machine to provide make up in the event of a loss of sodium from the handling tube during transport to the decay tank. 5 claims, 32 drawing figures

  17. Hypothenar hammer syndrome from ice hockey stick-handling.

    Science.gov (United States)

    Zayed, Mohamed A; McDonald, Joey; Tittley, Jacques G

    2013-11-01

    Ulnar artery thrombosis and hypothenar hammer syndrome are rare vascular complications that could potentially occur with repeated blows or trauma to the hand. Although initially reported as an occupational hazard among laborers and craftsmen, it has been observed more recently among recreationalists and athletes. Until now, it has never been reported as a complication in ice hockey players. In this case report, a 26-year-old Canadian professional ice hockey player presented with acute dominant right hand paleness, coolness, and pain with hand use. The patient used a wooden hockey stick with a large knob of tape at the end of the handle, which he regularly gripped in the palm of his right hand to help with face-offs and general stick-handling. Sonographic evaluation demonstrated no arterial flow in the distal right ulnar artery distribution, and ulnar artery occlusion with no aneurysmal degeneration was confirmed by magnetic resonance angiogram. Intraarterial thrombolytic therapy was initiated, and subsequent serial angiograms demonstrated significant improvement in distal ulnar artery flow as well as recanalization of right hand deep palmar arch and digital arteries. The patient's symptoms resolved, and he was maintained on therapeutic anticoagulation for 3 months prior to returning to playing ice hockey professionally, but with a padded glove and no tape knob at the handle tip. This case highlights a unique presentation of hockey stick-handling causing ulnar artery thrombosis that was likely from repeated palmar hypothenar trauma. Appropriate diagnostic imaging, early intraarterial thrombolysis, and postoperative surveillance and follow-up were crucial for the successful outcome in this patient. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Consumer Shell Egg Consumption and Handling Practices: Results from a National Survey.

    Science.gov (United States)

    Kosa, Katherine M; Cates, Sheryl C; Bradley, Samantha; Godwin, Sandria; Chambers, Delores

    2015-07-01

    Numerous cases and outbreaks of Salmonella infection are attributable to shell eggs each year in the United States. Safe handling and consumption of shell eggs at home can help reduce foodborne illness attributable to shell eggs. A nationally representative Web survey of 1,504 U.S. adult grocery shoppers was conducted to describe consumer handling practices and consumption of shell eggs at home. Based on self-reported survey data, most respondents purchase shell eggs from a grocery store (89.5%), and these eggs were kept refrigerated (not at room temperature; 98.5%). As recommended, most consumers stored shell eggs in the refrigerator (99%) for no more than 3 to 5 weeks (97.6%). After cracking eggs, 48.1% of respondents washed their hands with soap and water. More than half of respondents who fry and/or poach eggs cooked them so that the whites and/or the yolks were still soft or runny, a potentially unsafe practice. Among respondents who owned a food thermometer (62.0%), only 5.2% used it to check the doneness of baked egg dishes when they prepared such a dish. Consumers generally followed two of the four core "Safe Food Families" food safety messages ("separate" and "chill") when handling shell eggs at home. To prevent Salmonella infection associated with shell eggs, consumers should improve their practices related to the messages "clean" (i.e., wash hands after cracking eggs) and "cook" (i.e., cook until yolks and whites are firm and use a food thermometer to check doneness of baked egg dishes) when preparing shell eggs at home. These findings will be used to inform the development of science-based consumer education materials that can help reduce foodborne illness from Salmonella infection.

  19. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R., E-mail: dcsouza@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karam@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-07-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  20. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    International Nuclear Information System (INIS)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R.; Karam Junior, Dib

    2015-01-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  1. A cross-sectional study of sputum handling by and supervision of patients with pulmonary tuberculosis treated at home in China.

    Science.gov (United States)

    Mei, L; Tobe, R G; Geng, H; Ma, Y B; Li, R Y; Wang, W B; Selotlegeng, L; Wang, X Z; Xu, L Z

    2012-12-01

    Disposal of sputum from patients with pulmonary tuberculosis (TB) who are treated at home is an important aspect of preventing the spread of TB. However, few studies have examined disposal of sputum by patients with TB who are treated at home. Patients with pulmonary TB who are treated at home were surveyed regarding sputum handling and supervision. A cross-sectional survey of a representative sample of patients with pulmonary TB who are treated at home was conducted in Shandong Province. Participants were individuals with TB who had been registered with a local agency responsible for TB control. Participants completed a questionnaire with both qualitative and quantitative questions. How sputum was handled was determined and factors associated with sputum disposal were analyzed using a non-parametric test, logistic regression, and content analysis. Responses were received from 720 participants. Patients expectorated sputum 4.56 ± 10.367 times a day, and 68.6% of patients responded that they correctly disposed of their sputum. Supervision as part of TB control focused on the efforts of health agencies and paid little attention to waste management by patients. A non-parametric test showed that sputum disposal was significantly associated with gender, age, education, sputum smear results, attitudes toward waste management, and attitudes toward supervision (all p definition, details, and methods of supervision of waste management by patients with TB to give them relevant health education and enhance their willingness to be supervised. A financial incentive should be provided to health workers supervising management of TB-related waste.

  2. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  3. Handling And Safety Aspects Of Fiber Optic Laser Beam Delivery Systems

    Science.gov (United States)

    Schonborn, K.-H.; Wodrich, W.

    1988-06-01

    Using lasers for therapeutic applications is getting more and more accepted. In ophthalmology Ar-lasers for intraocular applications are quite common. The Nd:YAG-laser is used as a high power tool in connection with silica fibers for different extracorporal and intracorporal applications. The CO2-laser is the cutting laser, one problem being the beam transmission: The state of the art in fibers is not sufficient up to now. Because of the high power used safety against laser radiation hazard is of great importance. The safety in laser use is primarily dependent on the surgeons cautiousness, e.g. using laser protection goggels, observing that the spot of the aiming beam is present etc. On the other hand the laser and fiber system has to be inherently safe by appropriate technical means as far as possible. An additional aspect adding to safety is the handling: With easier system handling less attention of the surgeon is necessary for driving the apparatus. Thus he can concentrate on the patient and on the procedure. In considering the fiber system one important point in handling and safety is the coupling of the fiber to the laser head. The development philosophy in this coupling may be divided into two groups: - one is trying to use standard connectors which were initially developed for data transmission; - the other is using special connectors. One example of the first group is the guiding of the laser beam from the Ar-laser to the slit-lamp in ophtalmology. Here the well-known F-SMA connectors together with a special fiber with adapted numerical aperture are used. The advantage of such a system is the low price of the connector. For high power lasers such as the clinical Nd:YAG lasers with 40 to 150 W those connectors are not suitable. Up to now every laser manufacturer developed his own connector system in this field.

  4. Consumer food handling in the home: a review of food safety studies.

    Science.gov (United States)

    Redmond, Elizabeth C; Griffith, Christopher J

    2003-01-01

    Epidemiological data from Europe, North America, Australia, and New Zealand indicate that a substantial proportion of foodborne disease is attributable to improper food preparation practices in consumers' homes. International concern about consumer food safety has prompted considerable research to evaluate domestic food-handling practices. The majority of consumer food safety studies in the last decade have been conducted in the United Kingdom and Northern Ireland (48%) and in the United States (42%). Surveys (questionnaires and interviews), the most frequent means of data collection, were used in 75% of the reviewed studies. Focus groups and observational studies have also been used. One consumer food safety study examined the relationship between pathogenic microbial contamination from raw chicken and observed food-handling behaviors, and the results of this study indicated extensive Campylobacter cross-contamination during food preparation sessions. Limited information about consumers' attitudes and intentions with regard to safe food-handling behaviors has been obtained, although a substantial amount of information about consumer knowledge and self-reported practices is available. Observation studies suggest that substantial numbers of consumers frequently implement unsafe food-handling practices. Knowledge, attitudes, intentions, and self-reported practices did not correspond to observed behaviors, suggesting that observational studies provide a more realistic indication of the food hygiene actions actually used in domestic food preparation. An improvement in consumer food-handling behavior is likely to reduce the risk and incidence of foodborne disease. The need for the development and implementation of food safety education strategies to improve specific food safety behaviors is reviewed in this paper.

  5. Is exercise training safe and beneficial in patients receiving left ventricular assist device therapy?

    Science.gov (United States)

    Alsara, Osama; Perez-Terzic, Carmen; Squires, Ray W; Dandamudi, Sanjay; Miranda, William R; Park, Soon J; Thomas, Randal J

    2014-01-01

    Because a limited number of patients receive heart transplantation, alternative therapies, such as left ventricular assist device (LVAD) therapy, have emerged. Published studies have shown that LVAD implantation, by itself, improves exercise tolerance to the point where it is comparable to those with mild heart failure. The improvement in exercise capacity is maximally achieved 12 weeks after LVAD therapy and can continue even after explantation of the device. This effect varies, depending on the type of LVAD and exercise training. The available data in the literature on safety and benefits of exercise training in patients after LVAD implantation are limited, but the data that are available suggest that training trends to be safe and have an impact on exercise capacity in LVAD patients. Although no studies were identified on the role of cardiac rehabilitation programs in the management of LVAD patients, it appears that cardiac rehabilitation programs offer an ideal setting for the provision of supervised exercise training in this patient group.

  6. A SAFE PROTOCOL FOR RAPID DESENSITIZATION IN PATIENTS WITH CYSTIC FIBROSIS AND ANTIBIOTIC HYPERSENSITIVITY

    Science.gov (United States)

    Legere, Henry J.; Palis, Ross I.; Bouza, Tito Rodriguez; Uluer, Ahmet Z.; Castells, Mariana C.

    2009-01-01

    Background CF patients often demonstrate hypersensitivity to one or multiple antibiotics due to frequent and repeated exposures. Attempts at antibiotic desensitization in this population are historically complicated by higher reaction rates, failure to complete the procedure and consequent withholding of first-line therapy. This study evaluates the outcomes of a rapid desensitization protocol developed at our institution. Methods We retrospectively reviewed the medical records of 15 patients undergoing 52 rapid antibiotic desensitizations at Brigham and Women’s Hospital and Children’s Hospital Boston utilizing our protocol. Results Mean FEV1 % predicted was 44.1 (SD 16.5), with two patients at desensitized during bilateral lung transplantation. Adverse reactions during desensitization occurred in 13.4%, and most were mild. 100% of patients completed the protocol and ultimately tolerated subsequent full-strength antibiotic courses. Conclusions CF patients with antibiotic hypersensitivity can safely receive first-line antibiotics via our rapid desensitization protocol, including those with severe obstructive lung disease. PMID:19740711

  7. REMOTE MATERIAL HANDLING IN THE YUCCA MOUNTAIN WASTE PACKAGE CLOSURE CELL AND SUPPORT AREA GLOVEBOX

    International Nuclear Information System (INIS)

    K.M. Croft; S.M. Allen; M.W. Borland

    2005-01-01

    The Yucca Mountain Waste Package Closure System (WPCS) cells provide for shielding of highly radioactive materials contained in unsealed waste packages. The purpose of the cells is to provide safe environments for package handling and sealing operations. Once sealed, the packages are placed in the Yucca Mountain Repository. Closure of a typical waste package involves a number of remote operations. Those involved typically include the placement of matched lids onto the waste package. The lids are then individually sealed to the waste package by welding. Currently, the waste package includes three lids. One lid is placed before movement of the waste package to the closure cell; the final two are placed inside the closure cell, where they are welded to the waste package. These and other important operations require considerable remote material handling within the cell environment. This paper discusses the remote material handling equipment, designs, functions, operations, and maintenance, relative to waste package closure

  8. Chemotherapy drug handling in first opinion small animal veterinary practices in the United Kingdom: results of a questionnaire survey.

    Science.gov (United States)

    Edery, E G

    2017-05-27

    To investigate how first opinion small animal veterinary surgeons in the UK handled chemotherapeutic agents, a questionnaire was distributed at the 2014 British Small Animal Veterinary Association congress and by internet. Chemotherapy was regularly offered by 70.4 per cent of the respondents. Gold standards defined according to available guidelines for safe handling of antineoplastic drugs were poorly followed by general practitioners with only 2 per cent of respondents complying with all of them. Dedicated facilities for preparation and administration of cytotoxic drugs were variably available among participants. The level of training of staff indirectly involved in handling chemotherapy was appropriate in less than 50 per cent of practices. No association was found between demographic characteristics of the sampled population and the decision to perform chemotherapy. The results of this study raise concerns about the safety of the veterinary staff in first opinion practices involved in handling chemotherapy. British Veterinary Association.

  9. Safe sex

    Science.gov (United States)

    ... sex; Sexually transmitted - safe sex; GC - safe sex; Gonorrhea - safe sex; Herpes - safe sex; HIV - safe sex; ... contact. STIs include: Chlamydia Genital herpes Genital warts Gonorrhea Hepatitis HIV HPV Syphilis STIs are also called ...

  10. Pancreas and liver resection in Jehovah's Witness patients: feasible and safe.

    Science.gov (United States)

    Konstantinidis, Ioannis T; Allen, Peter J; D'Angelica, Michael I; DeMatteo, Ronald P; Fischer, Mary E; Grant, Florence; Fong, Yuman; Kingham, T Peter; Jarnagin, William R

    2013-12-01

    Jehovah's Witness (JW) patients undergoing liver or pancreas surgery represent a challenging ethical and medical problem, with few reports about their optimal management. To analyze the perioperative outcomes of JW patients submitted to hepatic or pancreatic resection, clinicopathologic data of JW patients who underwent surgical exploration for a hepatic or pancreatic tumor between March 1996 and July 2011 were reviewed retrospectively. Clinicopathologic data of 27 patients, 28 explorations, and 25 resections were included. Median age was 58 years (range 28 to 75 years) and 20 patients were female. Three patients were explored and deemed unresectable. Fifteen hepatic resections (9 segmentectomy or bi/trisegmentectomy, 6 hemi-hepatectomy or extended hepatectomy) and 10 pancreatic resections (6 pancreaticoduodenectomy, 4 distal pancreatectomy/splenectomy) were reviewed; additional organs were resected in 5 patients (2 gastrectomy, 1 colectomy, 1 nephrectomy, 1 adrenalectomy, 1 salpingoophorectomy). Median estimated blood loss for the hepatectomies was 400 mL (range 100 to 1,500 mL) and for the pancreatectomies was 400 mL (range 250 to 1,800 mL). Six patients received preoperative erythropoietin; hemodilution was used in 9 patients and 3 had Cell Saver-generated autotransfusions. Median preoperative hemoglobin was 12.5 g/dL (range 9.5 to 14.4 g/dL) and median postoperative hemoglobin was 10.4 g/dL (range 9 to 12.4 g/dL). In-hospital mortality was 0%. One patient required re-exploration for decreasing hemoglobin and refusal of transfusion; a total of 11 complications developed in 7 other patients (5 wound infection/breakdown, 1 urinary tract infection, 1 ileus, 1 nausea/vomiting, 1 lymphedema, 1 ascites, and 1 ARDS). Median hospital stay was 7 days (range 4 to 23 days). Pancreatic and liver resection can be done safely in selected JW patients who refuse blood products by using a variety of blood-conservation techniques to help spare red cell mass. Copyright © 2013

  11. Human Mesenchymal Stem Cell Transfusion Is Safe and Improves Liver Function in Acute-on-Chronic Liver Failure Patients

    OpenAIRE

    Shi, Ming; Zhang, Zheng; Xu, Ruonan; Lin, Hu; Fu, Junliang; Zou, Zhengsheng; Zhang, Aimin; Shi, Jianfei; Chen, Liming; Lv, Sa; He, Weiping; Geng, Hua; Jin, Lei; Liu, Zhenwen; Wang, Fu-Sheng

    2012-01-01

    This study assessed the safety and initial efficacy of umbilical cord-derived mesenchymal stem cell (UC-MSC) transfusions for acute-on-chronic liver failure (ACLF) patients associated with hepatitis B virus (HBV) infection. No significant side effects were observed, and the UC-MSC transfusions significantly increased the survival rates in ACLF patients. It was found that UC-MSC transfusions are safe in the clinic and may serve as a novel therapeutic approach for HBV-associated ACLF patients.

  12. Does adding ketamine to morphine patient-controlled analgesia safely improve post-thoracotomy pain?

    Science.gov (United States)

    Mathews, Timothy J; Churchhouse, Antonia M D; Housden, Tessa; Dunning, Joel

    2012-02-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was 'is the addition of ketamine to morphine patient-controlled analgesia (PCA) following thoracic surgery superior to morphine alone'. Altogether 201 papers were found using the reported search, of which nine represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. This consisted of one systematic review of PCA morphine with ketamine (PCA-MK) trials, one meta-analysis of PCA-MK trials, four randomized controlled trials of PCA-MK, one meta-analysis of trials using a variety of peri-operative ketamine regimes and two cohort studies of PCA-MK. Main outcomes measured included pain score rated on visual analogue scale, morphine consumption and incidence of psychotomimetic side effects/hallucination. Two papers reported the measurements of respiratory function. This evidence shows that adding ketamine to morphine PCA is safe, with a reported incidence of hallucination requiring intervention of 2.9%, and a meta-analysis finding an incidence of all central nervous system side effects of 18% compared with 15% with morphine alone, P = 0.31, RR 1.27 with 95% CI (0.8-2.01). All randomized controlled trials of its use following thoracic surgery found no hallucination or psychological side effect. All five studies in thoracic surgery (n = 243) found reduced morphine requirements with PCA-MK. Pain scores were significantly lower in PCA-MK patients in thoracic surgery papers, with one paper additionally reporting increased patient satisfaction. However, no significant improvement was found in a meta-analysis of five papers studying PCA-MK in a variety of surgical settings. Both papers reporting respiratory outcomes found improved oxygen saturations and PaCO(2) levels in PCA-MK patients following thoracic surgery

  13. Is it safe to treat hyperthyroid patients with I-131 without fear of thyroid storm?

    International Nuclear Information System (INIS)

    Vijayakumar, V.; Nusynowitz, M.L.; Ali, S.

    2006-01-01

    Thyroid storm is extremely rare. However, hyperthyroid patients with severe thyrotoxicosis are frequently not treated immediately with I-131 for fear of thyroid storm but are placed on thiouracil drugs for varying periods of time. We demonstrate herein that it is safe to treat these patients with I-131, without pretreatment with thiouracil drugs, provided they do not have complicating intercurrent disease. Our definition of severe hyperthyroidism includes marked signs and symptoms of thyrotoxicosis, suppressed thyroid stimulating hormone (TSH), markedly elevated free T4 and/or free T3 and elevated radioactive iodine uptake (RAIU) (>30%) at 4 or 24 hours. Our diagnostic criteria for thyroid storm include two or more findings of fever (>38 deg C, 100 deg F), severe tachycardia, high pulse pressure, agitation with tremors, flushing, sweating, heart failure, nausea, vomiting, diarrhea, jaundice associated with high free T4 and/or free T3. Patients were selected retrospectively for the period between August 2003 and December 2004. One hundred and twenty-two patient visits were identified. These patients were treated with 370-740 MBq (10-20 mCi) of I-131 and were evaluated for any evidence of thyroid storm. Most of the patients were placed on beta blocker drugs at the time of initial I-131 therapy; these were continued for at least two months, when the first follow-up visit occurred. At the time of I-131 therapy, it is our policy to educate the patients to seek immediate medical attention for exacerbation of symptoms of thyrotoxicosis. Not one of these patients developed thyroid storm. A subset of 25% of these cases with higher potential for thyroid storm (RAIU more than 65%, very marked signs and symptoms, and very markedly elevated free T4 and/or free T3) also tolerated the I-131 therapy well with marked clinical improvement and no exacerbation of the thyrotoxic state. It is safe to administer I-131 to patients who are severely hyperthyroid without fear of thyroid

  14. How safe is safe?

    International Nuclear Information System (INIS)

    Hughes, C.F.; Flood, M.

    1996-01-01

    60 and 70 degree convexo-concave valve. Nine hundred and one valves were implanted in Australia. Twelve strut fractures were reported. Two other patients have been explanted and have demonstrated 'single leg separation'. This particular problem was only investigated when two patients died of a fractured valve in the same hospital on the same day. A retrospective study of all known patients in Australia has shown poor follow up, lack of knowledge and indeed lack of interest in device failure modes. Consequently, the Australian and New Zealand Heart Valve Registry was established to track all implanted valves and to notify physicians of any new information. This is perhaps the first device-specific register in Australia. The safety of individual devices is often not known by manufacturers, regulators and clinicians alike. No follow up is available and large volume long term studies are yet to be implemented for the majority of devices. Without such studies and without mandatory problem reporting, the relative safety of medical devices will continue to be measured by banner headlines, sensational TV 'grabs' and protracted law suits. At present, only schemes such as the Problem Reporting Scheme can tell us (albeit vaguely) 'how safe is safe'

  15. The safe handling of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1964-12-31

    A narrative account of a minor contamination accident in a laboratory is used to demonstrate the important role of radiation protection measures in radioisotope work and the necessity of giving proper regard to such measures. It is primarily directed towards the research scientists and medical workers using radioisotopes on a relatively small scale

  16. Recommendations for cask features for robotic handling from the Advanced Handling Technology Project

    International Nuclear Information System (INIS)

    Drotning, W.

    1991-02-01

    This report describes the current status and recent progress in the Advanced Handling Technology Project (AHTP) initiated to explore the use of advanced robotic systems and handling technologies to perform automated cask handling operations at radioactive waste handling facilities, and to provide guidance to cask designers on the impact of robotic handling on cask design. Current AHTP tasks have developed system mock-ups to investigate robotic manipulation of impact limiters and cask tiedowns. In addition, cask uprighting and transport, using computer control of a bridge crane and robot, were performed to demonstrate the high speed cask transport operation possible under computer control. All of the current AHTP tasks involving manipulation of impact limiters and tiedowns require robotic operations using a torque wrench. To perform these operations, a pneumatic torque wrench and control system were integrated into the tool suite and control architecture of the gantry robot. The use of captured fasteners is briefly discussed as an area where alternative cask design preferences have resulted from the influence of guidance for robotic handling vs traditional operations experience. Specific robotic handling experiences with these system mock-ups highlight a number of continually recurring design principles: (1) robotic handling feasibility is improved by mechanical designs which emphasize operation with limited dexterity in constrained workspaces; (2) clearances, tolerances, and chamfers must allow for operations under actual conditions with consideration for misalignment and imprecise fixturing; (3) successful robotic handling is enhanced by including design detail in representations for model-based control; (4) robotic handling and overall quality assurance are improved by designs which eliminate the use of loose, disassembled parts. 8 refs., 15 figs

  17. Remote-handled transuranic waste study

    International Nuclear Information System (INIS)

    1995-10-01

    The Waste Isolation Pilot Plant (WIPP) was developed by the US Department of Energy (DOE) as a research and development facility to demonstrate the safe disposal of transuranic (TRU) radioactive wastes generated from the Nation's defense activities. The WIPP disposal inventory will include up to 250,000 cubic feet of TRU wastes classified as remote handled (RH). The remaining inventory will include contact-handled (CH) TRU wastes, which characteristically have less specific activity (radioactivity per unit volume) than the RH-TRU wastes. The WIPP Land Withdrawal Act (LWA), Public Law 102-579, requires a study of the effect of RH-TRU waste on long-term performance. This RH-TRU Waste Study has been conducted to satisfy the requirements defined by the LWA and is considered by the DOE to be a prudent exercise in the compliance certification process of the WIPP repository. The objectives of this study include: conducting an evaluation of the impacts of RH-TRU wastes on the performance assessment (PA) of the repository to determine the effects of Rh-TRU waste as a part of the total WIPP disposal inventory; and conducting a comparison of CH-TRU and RH-TRU wastes to assess the differences and similarities for such issues as gas generation, flammability and explosiveness, solubility, and brine and geochemical interactions. This study was conducted using the data, models, computer codes, and information generated in support of long-term compliance programs, including the WIPP PA. The study is limited in scope to post-closure repository performance and includes an analysis of the issues associated with RH-TRU wastes subsequent to emplacement of these wastes at WIPP in consideration of the current baseline design. 41 refs

  18. Food handling in the household environment as a vulnerability factor to foodborne diseases

    Directory of Open Access Journals (Sweden)

    Carla Rosane Paz Arruda Teo

    2016-06-01

    Full Text Available Introduction: the concept of food security and nutrition is based on the regular and sufficient access to food of adequate quality and it implies food safety as one of its dimensions. Objective: to analyze the sanitary and hygienic conditions of food handling in households in Chapecó (SC, Brazil. Materials and Methods: descriptive study with 138 households selected by systematic sampling to a 5% significance level and a 4% acceptable error. We applied a questionnaire to the person who was the responsible for food handling in each household. We used descriptive and inferential statistics and we interpreted the data according to health vulnerability framework. Results: we highlight that 50.7% (n=70 reported to just wash vegetables with water, 71% (n=98 reported to wash cutting boards with detergent and cold water, 33, 3% (n=46 reported the use of raw eggs. There was no association between the source of water supply and sanitary failures observed. Conclusions: safe food handling procedures are not adopted in a reasonable proportion of households, which may explain the vulnerability to foodborne diseases in these environments.

  19. Deploying Information Technology for Latent Poisoning Aversion during Handling and/or Usage of Agrochemicals

    OpenAIRE

    Nyagudi, Nyagudi Musandu

    2014-01-01

    Insights into safe use and handling of agrochemicals at of the year 2003 Paper Presented at two fora : Association of Medical Engineering of Kenya (AMEK), 2nd Annual Symposium and Exhibition held at the Nairobi Hospital from 28th to 30th October 2003 The Kenya ICT in Agriculture Conference. Theme : “Improving Agriculture in Kenya through Information & Communication Technology”. The 1st Annual ICT in Agriculture Conference, AMREF Training Centre, Nairobi, Kenya 29-30 October 2003 Orga...

  20. Microarray analysis of peripheral blood lymphocytes from ALS patients and the SAFE detection of the KEGG ALS pathway

    Science.gov (United States)

    2011-01-01

    Background Sporadic amyotrophic lateral sclerosis (sALS) is a motor neuron disease with poorly understood etiology. Results of gene expression profiling studies of whole blood from ALS patients have not been validated and are difficult to relate to ALS pathogenesis because gene expression profiles depend on the relative abundance of the different cell types present in whole blood. We conducted microarray analyses using Agilent Human Whole Genome 4 × 44k Arrays on a more homogeneous cell population, namely purified peripheral blood lymphocytes (PBLs), from ALS patients and healthy controls to identify molecular signatures possibly relevant to ALS pathogenesis. Methods Differentially expressed genes were determined by LIMMA (Linear Models for MicroArray) and SAM (Significance Analysis of Microarrays) analyses. The SAFE (Significance Analysis of Function and Expression) procedure was used to identify molecular pathway perturbations. Proteasome inhibition assays were conducted on cultured peripheral blood mononuclear cells (PBMCs) from ALS patients to confirm alteration of the Ubiquitin/Proteasome System (UPS). Results For the first time, using SAFE in a global gene ontology analysis (gene set size 5-100), we show significant perturbation of the KEGG (Kyoto Encyclopedia of Genes and Genomes) ALS pathway of motor neuron degeneration in PBLs from ALS patients. This was the only KEGG disease pathway significantly upregulated among 25, and contributing genes, including SOD1, represented 54% of the encoded proteins or protein complexes of the KEGG ALS pathway. Further SAFE analysis, including gene set sizes >100, showed that only neurodegenerative diseases (4 out of 34 disease pathways) including ALS were significantly upregulated. Changes in UBR2 expression correlated inversely with time since onset of disease and directly with ALSFRS-R, implying that UBR2 was increased early in the course of ALS. Cultured PBMCs from ALS patients accumulated more ubiquitinated proteins

  1. Why Oats Are Safe and Healthy for Celiac Disease Patients

    Directory of Open Access Journals (Sweden)

    Luud J. W. J. Gilissen

    2016-11-01

    Full Text Available The water-insoluble storage proteins of cereals (prolamins are called “gluten” in wheat, barley, and rye, and “avenins” in oat. Gluten can provoke celiac disease (CD in genetically susceptible individuals (those with human leukocyte antigen (HLA-DQ2 or HLA-DQ8 serotypes. Avenins are present at a lower concentration (10%–15% of total protein content in oat as compared to gluten in wheat (80%–85%. The avenins in the genus Avena (cultivated oat as well as various wild species of which gene bank accessions were analyzed are free of the known CD immunogenic epitopes from wheat, barley, and rye. T cells that recognize avenin-specific epitopes have been found very rarely in CD patients. CD patients that consume oats daily do not show significantly increased levels of intraepithelial lymphocyte (EIL cells. The safety and the positive health effects of the long-term inclusion of oats in the gluten-free diet have been confirmed in long-term studies. Since 2009 (EC 41/2009 and 2013 (FDA oat products may be sold as gluten-free in several countries provided a gluten contamination level below 20 ppm. Introduction of oats in the gluten-free diet of celiac patients is advised after the recovery of the intestine. Health effects of oat consumption are reflected in European Food Safety Authority (EFSA- and Food and Drug Administration (FDA-approved health claims. Oats can form a healthy, nutritious, fiber-rich, and safe complement to the gluten-free diet.

  2. 327 Building liquid waste handling options modification project plan

    International Nuclear Information System (INIS)

    Ham, J.E.

    1998-01-01

    This report evaluates the modification options for handling radiological liquid waste (RLW) generated during decontamination and cleanout of the 327 Building. The overall objective of the 327 Facility Stabilization Project is to establish a passively safe and environmentally secure configuration of the 327 Facility. The issue of handling of RLW from the 327 Facility (assuming the 34O Facility is not available to accept the RLW) has been conceptually examined in at least two earlier engineering studies (Parsons 1997a and Hobart l997). Each study identified a similar preferred alternative that included modifying the 327 Facility RLWS handling systems to provide a truck load-out station, either within the confines of the facility or exterior to the facility. The alternatives also maximized the use of existing piping, tanks, instrumentation, controls and other features to minimize costs and physical changes. An issue discussed in each study involved the anticipated volume of the RLW stream. Estimates ranged between 113,550 and 387,500 liters in the earlier studies. During the development of the 324/327 Building Stabilization/Deactivation Project Management Plan, the lower estimate of approximately 113,550 liters was confirmed and has been adopted as the baseline for the 327 Facility RLW stream. The goal of this engineering study is to reevaluate the existing preferred alternative and select a new preferred alternative, if appropriate. Based on the new or confirmed preferred alternative, this study will also provide a conceptual design and cost estimate for required modifications to the 327 Facility to allow removal of RLWS and treatment of the RLW generated during deactivation

  3. Physician discretion is safe and may lower stress test utilization in emergency department chest pain unit patients.

    Science.gov (United States)

    Napoli, Anthony M; Arrighi, James A; Siket, Matthew S; Gibbs, Frantz J

    2012-03-01

    Chest pain unit (CPU) observation with defined stress utilization protocols is a common management option for low-risk emergency department patients. We sought to evaluate the safety of a joint emergency medicine and cardiology staffed CPU. Prospective observational trial of consecutive patients admitted to an emergency department CPU was conducted. A standard 6-hour observation protocol was followed by cardiology consultation and stress utilization largely at their discretion. Included patients were at low/intermediate risk by the American Heart Association, had nondiagnostic electrocardiograms, and a normal initial troponin. Excluded patients were those with an acute comorbidity, age >75, and a history of coronary artery disease, or had a coexistent problem restricting 24-hour observation. Primary outcome was 30-day major adverse cardiovascular events-defined as death, nonfatal acute myocardial infarction, revascularization, or out-of-hospital cardiac arrest. A total of 1063 patients were enrolled over 8 months. The mean age of the patients was 52.8 ± 11.8 years, and 51% (95% confidence interval [CI], 48-54) were female. The mean thrombolysis in myocardial infarction and Diamond & Forrester scores were 0.6% (95% CI, 0.51-0.62) and 33% (95% CI, 31-35), respectively. In all, 51% (95% CI, 48-54) received stress testing (52% nuclear stress, 39% stress echocardiogram, 5% exercise, 4% other). In all, 0.9% patients (n = 10, 95% CI, 0.4-1.5) were diagnosed with a non-ST elevation myocardial infarction and 2.2% (n = 23, 95% CI, 1.3-3) with acute coronary syndrome. There was 1 (95% CI, 0%-0.3%) case of a 30-day major adverse cardiovascular events. The 51% stress test utilization rate was less than the range reported in previous CPU studies (P < 0.05). Joint emergency medicine and cardiology management of patients within a CPU protocol is safe, efficacious, and may safely reduce stress testing rates.

  4. Safe and effective use of medicines for ethnic minorities

    DEFF Research Database (Denmark)

    Dam, Pernille; El-Souri, Mira Mahmoud; Herborg, Hanne

    2015-01-01

    , there was a need to adapt a previously developed and validated medicine-based intervention “safe and effective use of medicines” to this vulnerable group of unemployed ethnic minority patients. Methods: The objective of this before-after study was to improve medicines adherence, health status and work ability...... of the target group through an individualized pharmacist delivered intervention with focus on safe and effective implementation of medical treatments. The target group was ethnic minorities of non-western origin affiliated with a job center. Results: At baseline, 35.7 % of the patients had a potential adherence...... to the intervention. Conclusion: The counseling program “Safe and effective use of medicines” was successfully adapted to unemployed ethnic minority patients, and tested in a new collaboration between job centers and community pharmacies. The counseling program resulted in statistically significant improvements...

  5. SRTC criticality technical review: Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility

    International Nuclear Information System (INIS)

    Rathbun, R.

    1993-01-01

    Separate review of NMP-NCS-930058, open-quotes Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility (U), August 17, 1993,close quotes was requested of SRTC Applied Physics Group. The NCSE is a criticality assessment to determine waste container uranium limits in the Uranium Solidification Facility's Waste Handling Facility. The NCSE under review concludes that the NDA room remains in a critically safe configuration for all normal and single credible abnormal conditions. The ability to make this conclusion is highly dependent on array limitation and inclusion of physical barriers between 2x2x1 arrays of boxes containing materials contaminated with uranium. After a thorough review of the NCSE and independent calculations, this reviewer agrees with that conclusion

  6. Quality assurance: recommended guidelines for safe heating by capacitive-type heating technique to treat patients with metallic implants.

    Science.gov (United States)

    Kato, Hirokazu; Kondo, Motoharu; Imada, Hajime; Kuroda, Masahiro; Kamimura, Yoshitsugu; Saito, Kazuyuki; Kuroda, Kagayaki; Ito, Koichi; Takahashi, Hideaki; Matsuki, Hidetoshi

    2013-05-01

    This article is a redissemination of the previous Japanese Quality Assurance Guide guidelines. Specific absorption rate and temperature distribution were investigated with respect to various aspects including metallic implant size and shape, insertion site, insertion direction, blood flow and heating power, and simulated results were compared with adverse reactions of patients treated by radio frequency capacitive-type heating. Recommended guidelines for safe heating methods for patients with metallic implants are presented based on our findings.

  7. Analysis of ITER upper port plug remote handling maintenance scenarios

    International Nuclear Information System (INIS)

    Koning, J.F.; Baar, M.R. de; Elzendoorn, B.S.Q.; Heemskerk, C.J.M.; Ronden, D.M.S.; Schuth, W.J.

    2012-01-01

    Highlights: ► Remote Handling Study Centre: providing RH compatibility analysis. ► Simulation: virtual reality including kinematics and realtime physics simulator. ► Applied on analysis of RH compatibility of Upper Launcher component replacement. ► Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  8. Analysis of ITER upper port plug remote handling maintenance scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Koning, J.F., E-mail: j.f.koning@heemskerk-innovative.nl [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Baar, M.R. de; Elzendoorn, B.S.Q. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M. [Heemskerk Innovative Technology, Noordwijk (Netherlands); Ronden, D.M.S.; Schuth, W.J. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Remote Handling Study Centre: providing RH compatibility analysis. Black-Right-Pointing-Pointer Simulation: virtual reality including kinematics and realtime physics simulator. Black-Right-Pointing-Pointer Applied on analysis of RH compatibility of Upper Launcher component replacement. Black-Right-Pointing-Pointer Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  9. Determination of a safe INR for joint injections in patients taking warfarin.

    Science.gov (United States)

    Bashir, M A; Ray, R; Sarda, P; Li, S; Corbett, S

    2015-11-01

    With an increase in life expectancy in 'developed' countries, the number of elderly patients receiving joint injections for arthritis is increasing. There are legitimate concerns about an increased risk of thromboembolism if anticoagulation is stopped or reversed for such an injection. Despite being a common dilemma, the literature on this issue is scarce. We undertook 2,084 joint injections of the knee and shoulder in 1,714 patients between August 2008 and December 2013. Within this cohort, we noted 41 patients who were taking warfarin and followed them immediately after joint injection in the clinic or radiology department, looking carefully for complications. Then, we sought clinical follow-up, correspondence, and imaging evidence for 4 weeks, looking for complications from these joint injections. We recorded International Normalised Ratio (INR) values before injection. No complications were associated with the procedure after any joint injection. The radiologists who undertook ultrasound-guided injections to shoulders re-scanned the joints looking for haemarthroses: they found none. A similar outcome was noted clinically after injections in the outpatient setting. With a mean INR of 2.77 (range, 1.7-5.5) and a maximum INR within this group of 5.5, joint injections to the shoulder and knee can be undertaken safely in primary or secondary care settings despite the patient taking warfarin.

  10. Waste Handling Equipment Development Test and Evaluation Study

    International Nuclear Information System (INIS)

    R.L. Tome

    1998-01-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M and O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T and EP), Reference 5.1, was used as a basis for this study. The MGR T and EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T and EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T and EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  11. Emergency handling of radiation accident cases: firemen

    International Nuclear Information System (INIS)

    Procedures for the emergency handling of persons exposed to radiation or radioactive contamination are presented, with emphasis on information needed by firemen. The types of radiation accident patients that may be encountered are described and procedures for first aid, for preventing the spread of radioactive contamination, and for reporting the accident are outlined

  12. Museopathy: Exploring the Healing Potential of Handling Museum Objects

    Directory of Open Access Journals (Sweden)

    Helen Chatterjee

    2009-11-01

    Full Text Available To coincide with emerging arts and health practices, University College London Museums & Collections and University College London Hospitals Arts partnered to create a pilot project, entitled “Heritage in Hospitals”, which sought to assess whether handling museum objects has a positive impact on patient wellbeing. Quantitative data from 32 sessions conducted with patients in May through July (inclusive of 2008 demonstrated, on average, an increase in self-reported measures of life satisfaction and health status after handling museum objects. Constant comparative analysis of the qualitative data collected from the sessions revealed two major recurring themes: “impersonal/educational” and “personal/reminiscence”. The first theme included instances where handling museum objects allowed patients to access truths about the objects ascertainable solely through touch (such as gauging weight, texture, temperature, and spatial relation to the body, to verify what was seen, to facilitate an intimate and imaginative connection with the museum objects and their origins, to investigate and explore the objects, to permit an interaction with the “rare” and “museum-worthy”, and to assist with aesthetic appreciation. The second theme illustrated the project’s potential to assist with counselling on issues of illness, death, loss and mourning, and to help restore dignity, respect and a sense of identity (particularly among elderly patients by providing a springboard for reminiscing and the telling of life stories in a highly institutionalized setting. This paper contextualizes the project, explores the implications of the project’s methodology and its findings, and provides questions for future research.

  13. Safety Analysis of 'Older/Aged' Handling and Transportation Equipment for Heavy Loads, Radioactive Waste and Materials in Accordance with German Nuclear Standards KTA 3902, 3903 and 3905

    International Nuclear Information System (INIS)

    Macias, P.; Prucker, E.; Stang, W.

    2006-01-01

    The purpose of this paper is to present a general safety analysis of important handling and transportation processes and their related equipment ('load chains' consisting of cranes, load-bearing equipment and load-attaching points). This project was arranged by the responsible Bavarian ministry for environment, health and consumer protection (StMUGV) in agreement with the power plant operators of all Bavarian nuclear power plants to work out potential safety improvements. The range of the equipment (e.g. reactor building, crane, refuelling machine, load-bearing equipment and load-attaching points) covers the handling and transportation of fuel elements (e. g. with fuel flasks), heavy loads (e.g. reactor pressure vessel closure head, shielding slabs) and radioactive materials and waste (e.g. waste flasks, control elements, fuel channels, structure elements). The handling equipment was subjected to a general safety analysis taking into account the ageing of the equipment and the progress of standards. Compliance with the current valid requirements of the state of science and technology as required by German Atomic Act and particularly of the nuclear safety KTA-standards (3902, 3903 and 3905) was examined. The higher protection aims 'safe handling and transportation of heavy loads and safe handling of radioactive materials and waste' of the whole analysis are to avoid a criticality accident, the release of radioactivity and inadmissible effects on important technical equipment and buildings. The scope of the analysis was to check whether these protection aims were fulfilled for all important technical handling and transportation processes. In particularly the design and manufacturing of the components and the regulations of the handling itself were examined. (authors)

  14. Barriers to Timely and Safe Blood Transfusion for PPH Patients: Evidence from a Qualitative Study in Dhaka, Bangladesh.

    Science.gov (United States)

    Akhter, Sadika; Anwar, Iqbal; Akter, Rashida; Kumkum, Feroza Akhter; Nisha, Monjura Khatun; Ashraf, Fatema; Islam, Ferdousi; Begum, Nazneen; Chowdhury, Mahbub Elahi; Austin, Anne; Islam, Syed Shariful; Rahman, Aminur

    2016-01-01

    In Bangladesh, postpartum hemorrhage (PPH) is the leading cause of maternal mortality accounting for 31% of all blood transfusions in the country. Although safe blood transfusion is one of the 8 signal functions of Comprehensive Emergency Obstetric Care (CEmOC) strategy, most of the designated public sector CEmOC facilities do not have on-site blood storage system. Emergent blood is mainly available from external blood banks. As a result, emergent patients are to rely on an unregulated network of brokers for blood which may raise question about blood safety. This study explored lived experiences of patients' attendants, managers, providers, and blood brokers before and after the implementation of an on-line Blood Information and Management Application (BIMA) in regards to barriers and facilitators of blood transfusion for emergent patients. Data were collected at Dhaka Medical College Hospital (DMCH), a tertiary-level teaching hospital before (January 2014) and after (March 2015) the introduction of an online BIMA system. Data collection methods included 24 key informant interviews (KIIs) and 40 in-depth interviews (IDIs). KIIs were conducted with formal health service providers, health managers and unlicensed blood brokers. IDIs were conducted with the relatives and husbands of women who suffered PPH, and needed emergency blood. Patients' attendants were unaware of patients' blood type and availability of blood in emergency situation. Newly introduced online BIMA system could facilitate blood transfusion process for poor patients at lower cost and during any time of day and night. However, service providers and service recipients were heavily dependent on a network of unlicensed blood brokers for required blood for emergent PPH patients. Blood collected through unlicensed blood brokers is un-screened, unregulated and probably unsafe. Blood brokers feel that they are providing a needed service, acknowledged a financial incentive and unaware about safety of blood

  15. Barriers to Timely and Safe Blood Transfusion for PPH Patients: Evidence from a Qualitative Study in Dhaka, Bangladesh.

    Directory of Open Access Journals (Sweden)

    Sadika Akhter

    Full Text Available In Bangladesh, postpartum hemorrhage (PPH is the leading cause of maternal mortality accounting for 31% of all blood transfusions in the country. Although safe blood transfusion is one of the 8 signal functions of Comprehensive Emergency Obstetric Care (CEmOC strategy, most of the designated public sector CEmOC facilities do not have on-site blood storage system. Emergent blood is mainly available from external blood banks. As a result, emergent patients are to rely on an unregulated network of brokers for blood which may raise question about blood safety. This study explored lived experiences of patients' attendants, managers, providers, and blood brokers before and after the implementation of an on-line Blood Information and Management Application (BIMA in regards to barriers and facilitators of blood transfusion for emergent patients.Data were collected at Dhaka Medical College Hospital (DMCH, a tertiary-level teaching hospital before (January 2014 and after (March 2015 the introduction of an online BIMA system. Data collection methods included 24 key informant interviews (KIIs and 40 in-depth interviews (IDIs. KIIs were conducted with formal health service providers, health managers and unlicensed blood brokers. IDIs were conducted with the relatives and husbands of women who suffered PPH, and needed emergency blood.Patients' attendants were unaware of patients' blood type and availability of blood in emergency situation. Newly introduced online BIMA system could facilitate blood transfusion process for poor patients at lower cost and during any time of day and night. However, service providers and service recipients were heavily dependent on a network of unlicensed blood brokers for required blood for emergent PPH patients. Blood collected through unlicensed blood brokers is un-screened, unregulated and probably unsafe. Blood brokers feel that they are providing a needed service, acknowledged a financial incentive and unaware about safety

  16. Quantitative Risk Assessment of Patient Manual Handling in Wards of One of the Hospitals of Tehran using MAPO Method, Iran

    Directory of Open Access Journals (Sweden)

    Sajad Ataei

    2017-05-01

    Full Text Available Background and Objectives: Manual handling of disabled patients is one of the important and effective factors in acute low back pain among exposed nurses. The present study was conducted with the objective of quantitative risk assessment of patient manual handling among nurses in wards of one of the hospitals in Tehran using MAPO method. Methods: The present study was conducted as an analytical-cross-sectional study in 26 wards of one of the hospitals in Tehran city. Samples were selected by census method from nurses and paramedics of different wards of hospital. Data collection was performed using demographic information and MAPO checklist. Results: The highest score of MAPO were, respectively, related to wards of DI clinic (score, 14.7, men orthopedic (score, 6.3, and general operating room (score, 57. 53.8% of hospital wards were at the level 2 corrective action, which indicated that the risk of musculoskeletal disorder is 2.4 times higher than level 1 corrective action. Conclusion: Given that the proportion of disabled patient in cooperation and/or partial cooperation, lifting tools, auxiliary, wheelchair, and training have the most role among risk factors for above-mentioned wards, increasing the number of human resources and wheelchair, use of lifting and auxiliary tools and training reduce MAPO score and consequently the risk of musculoskeletal disorders.

  17. Rush immunotherapy for wasp venom allergy seems safe and effective in patients with mastocytosis.

    Science.gov (United States)

    Verburg, M; Oldhoff, J M; Klemans, R J B; Lahey-de Boer, A; de Bruin-Weller, M S; Röckmann, H; Sanders, C; Bruijnzeel-Koomen, C A F M; Pasmans, S G M A; Knulst, A C

    2015-11-01

    Patients with mastocytosis and wasp venom allergy (WA) may benefit from venom immunotherapy (VIT). However, fatal insect sting reactions have been described in mastocytosis patients despite previous immunotherapy. We investigated the safety and efficacy of (rush) VIT in patients with mastocytosis and WA. To investigate the safety and efficacy of (rush) VIT in patients with mastocytosis and WA. We describe nine patients with cutaneous mastocytosis and WA who received VIT. Cutaneous mastocytosis was confirmed by histopathology and systemic mastocytosis was diagnosed according to World Health Organization criteria. VIT was given according to a rush protocol. Given the difference in safety and efficacy of VIT in patients with WA and honeybee venom allergy, we reviewed the literature for VIT with the focus on WA patients with mastocytosis and addressed the difference between patients with cutaneous versus systemic mastocytosis. Nine patients had WA and mastocytosis, of whom six had cutaneous mastocytosis, two combined cutaneous and systemic mastocytosis and one systemic mastocytosis. All patients received rush IT with wasp venom. Most patients had only mild local side effects, with no systemic side effects during the course of VIT. One patient had a systemic reaction upon injection on one occasion, during the updosing phase, with dyspnoea and hypotension, but responded well to treatment. Immunotherapy was continued after temporary dose adjustment without problems. Two patients with a previous anaphylactic reaction were re-stung, without any systemic effects. VIT is safe in cutaneous mastocytosis patients with WA, while caution has to be made in case of systemic mastocytosis. VIT was effective in the patients who were re-stung.

  18. Syndrome of transient headache and neurological deficits with cerebrospinal fluid lymphocytosis (HaNDL) in a patient with confusional symptoms, diffuse EEG abnormalities, and bilateral vasospasm in transcranial Doppler ultrasound: A case report and literature review.

    Science.gov (United States)

    Hidalgo de la Cruz, M; Domínguez Rubio, R; Luque Buzo, E; Díaz Otero, F; Vázquez Alén, P; Orcajo Rincón, J; Prieto Montalvo, J; Contreras Chicote, A; Grandas Pérez, F

    2017-04-17

    HaNDL syndrome (transient headache and neurological deficits with cerebrospinal fluid lymphocytosis) is characterised by one or more episodes of headache and transient neurological deficits associated with cerebrospinal fluid lymphocytosis. To date, few cases of HaNDL manifesting with confusional symptoms have been described. Likewise, very few patients with HaNDL and confusional symptoms have been evaluated with transcranial Doppler ultrasound (TCD). TCD data from patients with focal involvement reveal changes consistent with vasomotor alterations. We present the case of a 42-year-old man who experienced headache and confusional symptoms and displayed pleocytosis, diffuse slow activity on EEG, increased blood flow velocity in both middle cerebral arteries on TCD, and single-photon emission computed tomography (SPECT) findings suggestive of diffuse involvement, especially in the left hemisphere. To our knowledge, this is the first description of a patient with HaNDL, confusional symptoms, diffuse slow activity on EEG, and increased blood flow velocity in TCD. Our findings suggest a relationship between cerebral vasomotor changes and the pathophysiology of HaNDL. TCD may be a useful tool for early diagnosis of HaNDL. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Use of CTX-I and PINP as bone turnover markers: National Bone Health Alliance recommendations to standardize sample handling and patient preparation to reduce pre-analytical variability.

    Science.gov (United States)

    Szulc, P; Naylor, K; Hoyle, N R; Eastell, R; Leary, E T

    2017-09-01

    The National Bone Health Alliance (NBHA) recommends standardized sample handling and patient preparation for C-terminal telopeptide of type I collagen (CTX-I) and N-terminal propeptide of type I procollagen (PINP) measurements to reduce pre-analytical variability. Controllable and uncontrollable patient-related factors are reviewed to facilitate interpretation and minimize pre-analytical variability. The IOF and the International Federation of Clinical Chemistry (IFCC) Bone Marker Standards Working Group have identified PINP and CTX-I in blood to be the reference markers of bone turnover for the fracture risk prediction and monitoring of osteoporosis treatment. Although used in clinical research for many years, bone turnover markers (BTM) have not been widely adopted in clinical practice primarily due to their poor within-subject and between-lab reproducibility. The NBHA Bone Turnover Marker Project team aim to reduce pre-analytical variability of CTX-I and PINP measurements through standardized sample handling and patient preparation. Recommendations for sample handling and patient preparations were made based on review of available publications and pragmatic considerations to reduce pre-analytical variability. Controllable and un-controllable patient-related factors were reviewed to facilitate interpretation and sample collection. Samples for CTX-I must be collected consistently in the morning hours in the fasted state. EDTA plasma is preferred for CTX-I for its greater sample stability. Sample collection conditions for PINP are less critical as PINP has minimal circadian variability and is not affected by food intake. Sample stability limits should be observed. The uncontrollable aspects (age, sex, pregnancy, immobility, recent fracture, co-morbidities, anti-osteoporotic drugs, other medications) should be considered in BTM interpretation. Adopting standardized sample handling and patient preparation procedures will significantly reduce controllable pre

  20. MR imaging of meniscal bucket-handle tears: a review of signs and their relation to arthroscopic classification

    International Nuclear Information System (INIS)

    Aydingoez, Uestuen; Firat, Ahmet K.; Atay, Ahmet Oe.; Doral, Nedim M.

    2003-01-01

    Our objective was to review the MR imaging signs of meniscal bucket-handle tears and assess the relevance of these signs to the arthroscopic classification of displaced meniscal tears. Forty-five menisci in 42 patients who had a diagnosis of bucket-handle tear either on MR imaging or on subsequent arthroscopy (in which Dandy's classification of meniscal tears was used) were retrospectively analyzed for MR imaging findings of double posterior cruciate ligament (PCL), fragment within the intercondylar notch, absent bow tie, flipped meniscus, double-anterior horn, and disproportional posterior horn signs. Arthroscopy, which was considered as the gold standard, revealed 41 bucket-handle tears (either diagnosed or not diagnosed by MR imaging) in 38 patients (33 males, 5 females). There was a stastistically significant male preponderance for the occurrence of meniscal bucket-handle tears. Overall, sensitivity and positive predictive value of MR imaging for the detection of meniscal bucket-handle tears were calculated as 90%. Common MR imaging signs of meniscal bucket-handle tears in arthroscopically proven cases of such tears were the fragment in the notch and absent bow tie signs (98% frequency for each). Double-PCL, flipped meniscus, double-anterior horn, and disproportional posterior horn signs, however, were less common (32, 29, 29, and 27%, respectively). An arthroscopically proven bucket-handle tear was found in all patients who displayed at least three of the six MR imaging signs of meniscal bucket-handle tears. The presence of three or more MR imaging signs of meniscal bucket-handle tears is highly suggestive of this condition. (orig.)

  1. Application of remote handling compatibility on ITER plant

    International Nuclear Information System (INIS)

    Sanders, S.; Rolfe, A.; Mills, S.F.; Tesini, A.

    2011-01-01

    The ITER plant will require fully remote maintenance during its operational life. For this to be effective, safe and efficient the plant will have to be developed in accordance with remote handling (RH) compatibility requirements. A system for ensuring RH compatibility on plant designed for Tokamaks was successfully developed and applied, inter alia, by the authors when working at the JET project. The experience gained in assuring RH compatibility of plant at JET is now being applied to RH relevant ITER plant. The methodologies required to ensure RH compatibility of plant include the standardization of common plant items, standardization of RH features, availability of common guidance on RH best practice and a protocol for design and interface review and approval. The protocol in use at ITER is covered by the ITER Remote Maintenance Management System (IRMMS) defines the processes and utilization of management controls including Plant Definition Forms (PDF), Task Definition Forms (TDFs) and RH Compatibility Assessment Forms (RHCA) and the ITER RH Code of Practice. This paper will describe specific examples where the authors have applied the methodology proven at JET to ensure remote handling compatibility on ITER plant. Examples studied are: ·ELM coils (to be installed in-vessel behind the Blanket Modules) - handling both in-vessel, in Casks and at the Hot Cell as well as fully remote installation and connection (mechanical and electrical) in-vessel. ·Neutral beam systems (in-vessel and in the NB Cell) - beam sources, cesium oven, beam line components (accessed in the NB Cell) and Duct Liner (remotely replaced from in-vessel). ·Divertor (in-vessel) - cooling pipe work and remotely operated electrical connector. The RH compatibility process can significantly affect plant design. This paper should therefore be of interest to all parties who develop ITER plant designs.

  2. Full scale tests on remote handled FFTF fuel assembly waste handling and packaging

    International Nuclear Information System (INIS)

    Allen, C.R.; Cash, R.J.; Dawson, S.A.; Strode, J.N.

    1986-01-01

    Handling and packaging of remote handled, high activity solid waste fuel assembly hardware components from spent FFTF reactor fuel assemblies have been evaluated using full scale components. The demonstration was performed using FFTF fuel assembly components and simulated components which were handled remotely using electromechanical manipulators, shielding walls, master slave manipulators, specially designed grapples, and remote TV viewing. The testing and evaluation included handling, packaging for current and conceptual shipping containers, and the effects of volume reduction on packing efficiency and shielding requirements. Effects of waste segregation into transuranic (TRU) and non-transuranic fractions also are discussed

  3. Handling Procedures of Vegetable Crops

    Science.gov (United States)

    Perchonok, Michele; French, Stephen J.

    2004-01-01

    The National Aeronautics and Space Administration (NASA) is working towards future long duration manned space flights beyond low earth orbit. The duration of these missions may be as long as 2.5 years and will likely include a stay on a lunar or planetary surface. The primary goal of the Advanced Food System in these long duration exploratory missions is to provide the crew with a palatable, nutritious, and safe food system while minimizing volume, mass, and waste. Vegetable crops can provide the crew with added nutrition and variety. These crops do not require any cooking or food processing prior to consumption. The vegetable crops, unlike prepackaged foods, will provide bright colors, textures (crispy), and fresh aromas. Ten vegetable crops have been identified for possible use in long duration missions. They are lettuce, spinach, carrot, tomato, green onion, radish, bell pepper, strawberries, fresh herbs, and cabbage. Whether these crops are grown on a transit vehicle (e.g., International Space Station) or on the lunar or planetary surface, it will be necessary to determine how to safely handle the vegetables while maintaining acceptability. Since hydrogen peroxide degrades into water and oxygen and is generally recognized as safe (GRAS), hydrogen peroxide has been recommended as the sanitizer. The objective of th is research is to determine the required effective concentration of hydrogen peroxide. In addition, it will be determined whether the use of hydrogen peroxide, although a viable sanitizer, adversely affects the quality of the vegetables. Vegetables will be dipped in 1 % hydrogen peroxide, 3% hydrogen peroxide, or 5% hydrogen peroxide. Treated produce and controls will be stored in plastic bags at 5 C for up to 14 days. Sensory, color, texture, and total plate count will be measured. The effect on several vegetables including lettuce, radish, tomato and strawberries has been completed. Although each vegetable reacts to hydrogen peroxide differently, the

  4. Role of non-destructive examinations in leak testing of glove boxes for industrial scale plutonium handling at nuclear fuel fabrication facility along with case study

    International Nuclear Information System (INIS)

    Aher, Sachin

    2015-01-01

    Non Destructive Examinations has the prominent role at Nuclear Fuel Fabrication Facilities. Specifically NDE has contributed at utmost stratum in Leak Testing of Glove Boxes and qualifying them as a Class-I confinement for safe Plutonium handling at industrial scale. Advanced Fuel Fabrication Facility, BARC, Tarapur is engaged in fabrication of Plutonium based MOX (PuO 2 , DDUO 2 ) fuel with different enrichments for first core of PFBR reactor. Alpha- Leak Tight Glove Boxes along with HEPA Filters and dynamic ventilation form the promising engineering system for safe and reliable handling of plutonium bearing materials considering the radiotoxicity and risk associated with handling of plutonium. Leak Testing of Glove Boxes which involves the leak detection, leak rectification and leak quantifications is major challenging task. To accomplish this challenge, various Non Destructive Testing methods have assisted in promising way to achieve the stringent leak rate criterion for commissioning of Glove Box facilities for plutonium handling. This paper highlights the Role of various NDE techniques like Soap Solution Test, Argon Sniffer Test, Pressure Drop/Rise Test etc. in Glove Box Leak Testing along with procedure and methodology for effective rectification of leakage points. A Flow Chart consisting of Glove Box leak testing procedure starting from preliminary stage up to qualification stage along with a case study and observations are discussed in this paper. (author)

  5. Enteral Feeding Set Handling Techniques.

    Science.gov (United States)

    Lyman, Beth; Williams, Maria; Sollazzo, Janet; Hayden, Ashley; Hensley, Pam; Dai, Hongying; Roberts, Cristine

    2017-04-01

    Enteral nutrition therapy is common practice in pediatric clinical settings. Often patients will receive a pump-assisted bolus feeding over 30 minutes several times per day using the same enteral feeding set (EFS). This study aims to determine the safest and most efficacious way to handle the EFS between feedings. Three EFS handling techniques were compared through simulation for bacterial growth, nursing time, and supply costs: (1) rinsing the EFS with sterile water after each feeding, (2) refrigerating the EFS between feedings, and (3) using a ready-to-hang (RTH) product maintained at room temperature. Cultures were obtained at baseline, hour 12, and hour 21 of the 24-hour cycle. A time-in-motion analysis was conducted and reported in average number of seconds to complete each procedure. Supply costs were inventoried for 1 month comparing the actual usage to our estimated usage. Of 1080 cultures obtained, the overall bacterial growth rate was 8.7%. The rinse and refrigeration techniques displayed similar bacterial growth (11.4% vs 10.3%, P = .63). The RTH technique displayed the least bacterial growth of any method (4.4%, P = .002). The time analysis in minutes showed the rinse method was the most time-consuming (44.8 ± 2.7) vs refrigeration (35.8 ± 2.6) and RTH (31.08 ± 0.6) ( P refrigerating the EFS between uses is the next most efficacious method for handling the EFS between bolus feeds.

  6. Safe management of cesarean section in a patient of Eisenmenger syndrome

    Directory of Open Access Journals (Sweden)

    Silvia Minicucci

    2012-01-01

    Full Text Available We report our experience of a 29-year-old female with a complete atrio-ventricular septal defect leading to a single ventricle physiology and Eisenmenger syndrome. The patient successfully underwent spinal anesthesia for cesarean section in the 31 st week of pregnancy. A multidisciplinary approach involving cardiologist, cardiac surgeon, obstetrician, and anesthesiologist was utilized to achieve a safe pregnancy and cesarean for the delivery of the baby. A close clinical assessment is required, especially during the third trimester when the risk of acute right ventricular dysfunction increases. The use of extracorporeal membrane oxygenation (ECMO (as a bridge to recovery or bridge to salvage was planned to support oxygenation and circulation in case of acute biventricular dysfunction. The delivery/cesarean section was performed in a cardiac surgery operating room, and to reduce the time-frame for ECMO institution the femoral vessels were exposed surgically before the cesarean section.

  7. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  8. Anamnestic prediction of bucket handle compared to other tear patterns of the medial meniscus in stable knees.

    Science.gov (United States)

    Haviv, Barak; Bronak, Shlomo; Kosashvili, Yona; Thein, Rafael

    2016-12-01

    The aim of this study was to analyze and compare the preoperative anamnestic details between patients with an arthroscopic diagnosis of bucket handle and other tear patterns of the medial meniscus in stable knees. A total of 204 patients (mean age 49.3 ± 13 years) were included in the study. The mean age was 49.3 ± 13 years. The study group included 65 patients (63 males, 2 females) with an arthroscopic diagnosis of bucket handle tear and the control group included 139 patients (90 males, 49 females) with non-bucket handle tear patterns. The preoperative clinical assessments of the two groups were analyzed retrospectively. Anamnestic prediction for the diagnosis of a bucket handle tear was based upon various medical history parameters. Multivariate logistic regression was carried out to identify independent anamnestic factors for predicting isolated bucket handle tears of the medial meniscus compared to non-bucket handle tears. Analysis of the multivariate logistic regression yielded 3 statistically significant independent anamnestic risk factors for predicting isolated bucket handle tears of the medial meniscus: male gender (OR, 9.7; 95% CI, 1.1-37.6), locking events (OR, 4.6; 95% CI, 1.8-11.3) and pain in extension (OR, 6.9; 95% CI, 2.5-23.7). Other preoperative variables such as age, BMI, activity level, comorbidities, duration of symptoms, pain location, preceding injury and its mechanism had no significant effect on tear pattern. Preoperative strong clues for bucket handle tears of the medial meniscus in stable knees are male gender, locking events and limitation in extension. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  9. Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong-Jin; Chung, June-Key; Kim, Sung-Eun; Kang, Won-Jun; Park, Do-Joon; Lee, Dong-Soo; Cho, Bo-Youn; Lee, Myung-Chul

    2008-01-01

    The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. Forty-seven differentiated thyroid carcinoma patients with non-responsive residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. Their postoperative pathologies were 43 papillary carcinomas and 4 follicular carcinomas. The MSD was calculated with the Memorial Sloan-Kettering Cancer Center protocol using serial blood samples. The MSDs were administered at intervals of 6 months. Treatment responses were evaluated using I-131 whole-body scans and serum thyroglobulin measurements. The mean calculated MSD was 12.5±2.1 GBq (339.6±57.5 mCi). Of the 46 patients, 7 (14.9%) showed complete remission, 15 (31.9%) partial remission, 19 (40.4%) stable disease, and 6 (12.8%) disease progression. Of the patients who showed complete or partial remission, 15 (65%) showed response after the first MSD session and 6 (26%) showed response after the second session. Twenty-nine patients (62%) experienced transient cytopenia after therapy, but three did not recover to the baseline level. The maximal safe dose provides an effective means of treatment in patients who failed to respond adequately to conventional fixed dose therapy. I-131 MSD therapy can be considered in patients who fail fixed dose therapy. (author)

  10. Higher Caloric Refeeding Is Safe in Hospitalised Adolescent Patients with Restrictive Eating Disorders

    Science.gov (United States)

    Parker, Elizabeth K.; Faruquie, Sahrish S.; Anderson, Gail; Gomes, Linette; Kennedy, Andrew; Wearne, Christine M.; Kohn, Michael R.; Clarke, Simon D.

    2016-01-01

    Introduction. This study examines weight gain and assesses complications associated with refeeding hospitalised adolescents with restrictive eating disorders (EDs) prescribed initial calories above current recommendations. Methods. Patients admitted to an adolescent ED structured “rapid refeeding” program for >48 hours and receiving ≥2400 kcal/day were included in a 3-year retrospective chart review. Results. The mean (SD) age of the 162 adolescents was 16.7 years (0.9), admission % median BMI was 80.1% (10.2), and discharge % median BMI was 93.1% (7.0). The mean (SD) starting caloric intake was 2611.7 kcal/day (261.5) equating to 58.4 kcal/kg (10.2). Most patients (92.6%) were treated with nasogastric tube feeding. The mean (SD) length of stay was 3.6 weeks (1.9), and average weekly weight gain was 2.1 kg (0.8). No patients developed cardiac signs of RFS or delirium; complications included 4% peripheral oedema, 1% hypophosphatemia (refeeding. Conclusion. A rapid refeeding protocol with the inclusion of phosphate supplementation can safely achieve rapid weight restoration without increased complications associated with refeeding syndrome. PMID:27293884

  11. Standards should be applied in the prevention and handling of missing data for patient-centered outcomes research: a systematic review and expert consensus.

    Science.gov (United States)

    Li, Tianjing; Hutfless, Susan; Scharfstein, Daniel O; Daniels, Michael J; Hogan, Joseph W; Little, Roderick J A; Roy, Jason A; Law, Andrew H; Dickersin, Kay

    2014-01-01

    To recommend methodological standards in the prevention and handling of missing data for primary patient-centered outcomes research (PCOR). We searched National Library of Medicine Bookshelf and Catalog as well as regulatory agencies' and organizations' Web sites in January 2012 for guidance documents that had formal recommendations regarding missing data. We extracted the characteristics of included guidance documents and recommendations. Using a two-round modified Delphi survey, a multidisciplinary panel proposed mandatory standards on the prevention and handling of missing data for PCOR. We identified 1,790 records and assessed 30 as having relevant recommendations. We proposed 10 standards as mandatory, covering three domains. First, the single best approach is to prospectively prevent missing data occurrence. Second, use of valid statistical methods that properly reflect multiple sources of uncertainty is critical when analyzing missing data. Third, transparent and thorough reporting of missing data allows readers to judge the validity of the findings. We urge researchers to adopt rigorous methodology and promote good science by applying best practices to the prevention and handling of missing data. Developing guidance on the prevention and handling of missing data for observational studies and studies that use existing records is a priority for future research. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Light water ultra-safe plant concept: First annual report

    International Nuclear Information System (INIS)

    Klevans, E.

    1987-01-01

    Since the accident at Three Mile Island (TMI) Penn State Nuclear Engineering Department Faculty and Staff have considered various methods to improve already safe reactor designs and public perception of the safety of Nuclear Power. During the last year, the Department of Energy funded the study of a plant reconfiguration originally proposed by M.A. Shultz. This report presents the status of the project at the end of the first year. A broad set of specifications to improve safety and public perception were set forth and the realization of these goals is achieved in a plant design named, ''The Light Water Ultra-Safe Plant Concept.'' The most significant goals of the concept address the station black-out problem and simplification of required operator actions during abnormal situations. These goals are achieved in the Ultra-Safe Concept by addition of an in-containment atmospheric tank containing a large quantity of cool water, replacement of the conventional PWR pressurizer system with a pressurizing pump, internal emergency power generation, and arrangement of components to utilize natural circulation at shut-down. The first year effort included an evaluation of the normal operation characteristics of the primary system pressurizing concept, evaluating parameters and modeling for analysis of the shutdown scenario, design of a low power density core, design of a low-pressure waste handling system, arrangement of a drainage system for pipe break considerations, and failure modes and effects analysis

  13. Associate Degree in Nursing-to-Bachelor of Science in Nursing Graduates' Education and Their Perceived Ability to Keep Patients Safe.

    Science.gov (United States)

    Anbari, Allison Brandt; Vogelsmeier, Amy

    2018-05-01

    Associate Degree in Nursing (ADN)-to-Bachelor of Science in Nursing (BSN) programs are designed to advance the ADN-prepared RNs' clinical reasoning and analytical skills. However, little is known about exactly how their BSN education may improve their clinical practice, specifically in the area of patient safety. During semi-structured one-to-one interviews, ADN-to-BSN graduates were asked about their educational process and the perceived affect their education made on their ability to keep patients safe. Content analysis were used to identify emerging themes and categories. Three themes emerged from the data: (a) an unaltered approach to keeping patients safe, (b) experience as an ADN matters, and (c) BSN degree as a stepping stone. The call to increase the number of BSN-prepared nurses at the bedside is supported in the evidence and noteworthy of pursuit. However, as ADN-to-BSN programs increase in numbers to meet this demand, the outcomes of graduates need to be considered. [J Nurs Educ. 2018;57(5):300-303.]. Copyright 2018, SLACK Incorporated.

  14. Working safely with radioactive materials

    International Nuclear Information System (INIS)

    Davies, Wynne

    1993-01-01

    In common with exposure to many other laboratory chemicals, exposure to ionising radiations and to radioactive materials carries a small risk of causing harm. Because of this, there are legal limits to the amount of exposure to ionising radiations at work and special rules for working with radioactive materials. Although radiation protection is a complex subject it is possible to simplify to 10 basic things you should do -the Golden Rules. They are: 1) understand the nature of the hazard and get practical training; 2) plan ahead to minimise time spent handling radioactivity; 3) distance yourself appropriately from sources of radiation; 4) use appropriate shielding for the radiation; 5) contain radioactive materials in defined work areas; 6) wear appropriate protective clothing and dosimeters; 7) monitor the work area frequently for contamination control; 8) follow the local rules and safe ways of working; 9) minimise accumulation of waste and dispose of it by appropriate routes, and 10) after completion of work, monitor, wash, and monitor yourself again. These rules are expanded in this article. (author)

  15. Is It safe? Nonoperative management of blunt splenic injuries in geriatric trauma patients.

    Science.gov (United States)

    Trust, Marc D; Teixeira, Pedro G; Brown, Lawrence H; Ali, Sadia; Coopwood, Ben; Aydelotte, Jayson D; Brown, Carlos V R

    2018-01-01

    Because of increased failure rates of nonoperative management (NOM) of blunt splenic injuries (BSI) in the geriatric population, dogma dictated that this management was unacceptable. Recently, there has been an increased use of this treatment strategy in the geriatric population. However, published data assessing the safety of NOM of BSI in this population is conflicting, and well-powered multicenter data are lacking. We performed a retrospective analysis of data from the National Trauma Data Bank (NTDB) from 2014 and identified young (age < 65) and geriatric (age ≥ 65) patients with a BSI. Patients who underwent splenectomy within 6 hours of admission were excluded from the analysis. Outcomes were failure of NOM and mortality. We identified 18,917 total patients with a BSI, 2,240 (12%) geriatric patients and 16,677 (88%) young patients. Geriatric patients failed NOM more often than younger patients (6% vs. 4%, p < 0.0001). On logistic regression analysis, Injury Severity Score of 16 or higher was the only independent risk factor associated with failure of NOM in geriatric patients (odds ratio, 2.778; confidence interval, 1.769-4.363; p < 0.0001). There was no difference in mortality in geriatric patients who had successful vs. failed NOM (11% vs. 15%; p = 0.22). Independent risk factors for mortality in geriatric patients included admission hypotension, Injury Severity Score of 16 or higher, Glasgow Coma Scale score of 8 or less, and cardiac disease. However, failure of NOM was not independently associated with mortality (odds ratio, 1.429; confidence interval, 0.776-2.625; p = 0.25). Compared with younger patients, geriatric patients had a higher but comparable rate of failed NOM of BSI, and failure rates are lower than previously reported. Failure of NOM in geriatric patients is not an independent risk factor for mortality. Based on our results, NOM of BSI in geriatric patients is safe. Therapeutic, level IV.

  16. Methods and apparatus for safely handling radioactive sources in measuring-while-drilling tools

    International Nuclear Information System (INIS)

    Wraight, P.D.

    1989-01-01

    This patent describes a method for removing a chemical radioactive source from a MWD tool which is coupled in a drill string supported by a drilling rig while a borehole is drilled and includes logging means for measuring formation characteristics in response to irradiation of the adjacent formations by the radioactive source during the drilling operation. The steps of the method are: halting the drilling operation and then removing the drill string from the borehole for moving the MWD tool to a work station at the surface where the source is at a safe working distance from the drilling rig and will be accessible by way of one end of the MWD tool; positioning a radiation shield at a location adjacent to the one end of the MWD tool where the shield is ready for receiving the source as it is moved away from the other end of the MWD tool and then moving the source away from the other end of the MWD tool for enclosing the source within the shield; and once the source is enclosed within the shield; removing the shield together with the enclosed source from the MWD tool for transferring the enclosed source to another work station

  17. Handling and processing of radioactive waste from nuclear applications

    International Nuclear Information System (INIS)

    2001-01-01

    The main objective of this report is to provide technical information and reference material on different steps and components of radioactive waste management for staff in establishments that use radionuclides and in research centres in Member States. It provides technical information on the safe handling, treatment, conditioning and storage of waste arising from the various activities associated with the production and application of radioisotopes in medical, industrial, educational and research facilities. The technical information cited in this report consists mainly of processes that are commercialised or readily available, and can easily be applied as they are or modified to solve specific waste management requirements. This report covers the sources and characteristics of waste and approaches to waste classification, and describes the particular processing steps from pretreatment until storage of conditioned packages

  18. 30o inclination in handles of plastic boxes can reduce postural and muscular workload during handling

    Directory of Open Access Journals (Sweden)

    Luciana C. C. B. Silva

    2013-06-01

    Full Text Available BACKGROUND: The handling of materials, which occurs in the industrial sector, is associated with lesions on the lumbar spine and in the upper limbs. Inserting handles in industrial boxes is a way to reduce work-related risks. Although the position and angle of the handles are significant factors in comfort and safety during handling, these factors have rarely been studied objectively. OBJECTIVE: To compare the handling of a commercial box and prototypes with handles and to evaluate the effects on upper limb posture, muscle electrical activity, and perceived acceptability using different grips while handling materials from different heights. METHOD: Thirty-seven healthy volunteers evaluated the handles of prototypes that allowed for changes in position (top and bottom and angle (0°, 15°, and 30°. Wrist, elbow, and shoulder movements were evaluated using electrogoniometry and inclinometry. The muscle electrical activity in the wrist extensors, biceps brachii, and the upper portion of the trapezius was measured using a portable electromyographer. The recorded data on muscle movements and electrical activity were synchronized. Subjective evaluations of acceptability were evaluated using a visual analog scale. RESULTS AND CONCLUSIONS: The prototypes with handles at a 30° angle produced the highest acceptability ratings, more neutral wrist positions, lower levels of electromyographic activity for the upper trapezius, and lower elevation angles for the arms. The different measurement methods were complementary in evaluating the upper limbs during handling.

  19. New transport and handling contract

    CERN Multimedia

    SC Department

    2008-01-01

    A new transport and handling contract entered into force on 1.10.2008. As with the previous contract, the user interface is the internal transport/handling request form on EDH: https://edh.cern.ch/Document/TransportRequest/ To ensure that you receive the best possible service, we invite you to complete the various fields as accurately as possible and to include a mobile telephone number on which we can reach you. You can follow the progress of your request (schedule, completion) in the EDH request routing information. We remind you that the following deadlines apply: 48 hours for the transport of heavy goods (up to 8 tonnes) or simple handling operations 5 working days for crane operations, transport of extra-heavy goods, complex handling operations and combined transport and handling operations in the tunnel. For all enquiries, the number to contact remains unchanged: 72202. Heavy Handling Section TS-HE-HH 72672 - 160319

  20. 76 FR 12719 - Safe Schools/Healthy Students Program; Office of Safe and Drug-Free Schools; Safe Schools/Healthy...

    Science.gov (United States)

    2011-03-08

    ... DEPARTMENT OF EDUCATION Safe Schools/Healthy Students Program; Office of Safe and Drug- Free Schools; Safe Schools/Healthy Students Program; Catalog of Federal Domestic Assistance (CFDA) Numbers: 84... priorities, requirements, and definitions under the Safe Schools/Healthy Students (SS/HS) program. Since...

  1. Laparoscopic posterior mesh rectopexy for rectal prolapse is a safe procedure in older patients

    DEFF Research Database (Denmark)

    Dyrberg, D L; Nordentoft, T; Rosenstock, S

    2015-01-01

    to 1 June 2012, 81 laparoscopic posterior rectopexies were done. Male-to-female ratio was 4:77, median age 73 [57-80.5] years and median ASA Grade 2. Conversion to open surgery was done in 6.2%, the median operating time was 82 min [66 - 102] and median length of hospital stay was 2 days [2-5.7]. Minor...... and major complications were seen in 5.3% and 14.8%, respectively. The 30-day mortality rate was 1.2%. Constipation or incontinence improved or disappeared in 65.2% and 74.4%, respectively. The cumulated recurrence rate was 11.1% after a median observation time of 2 years. CONCLUSION: Laparoscopic posterior...... rectopexy is a safe and well-tolerated procedure in older patients and can be done with acceptable complications and recurrence rates and short hospital stays. Laparoscopic posterior rectopexy seems to improve bowel function in many patients....

  2. Code of practice for the safe use of industrial radiography equipment (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    This code supersedes the Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography, published by the National Health and Medical Research Council (NHMRC) in 1968. It differs significantly from the former code because radiation protection practice and recommended standards have changed. The code covers the design, construction and requirements for the safe use of X-radiography equipment and gamma-radiography equipment. It provides illustrative working rules, detailed emergency procedures and comprehensive responsibilities and duties for all personnel involved in supplying and using industrial radiography equipment. The code details those equipment requirements, personnel requirements and work practices that the NHMRC considers necessary to keep exposures to ionizing radiation as low as reasonably achievable. Some equipment and facilities currently in use may not meet all of the mandatory requirements of this code. These requirements have been included in the code to encourage progress towards future compliance in the expectation that, in the interim, statutory authorities will apply them with discretion

  3. Trends in Modern Exception Handling

    Directory of Open Access Journals (Sweden)

    Marcin Kuta

    2003-01-01

    Full Text Available Exception handling is nowadays a necessary component of error proof information systems. The paper presents overview of techniques and models of exception handling, problems connected with them and potential solutions. The aspects of implementation of propagation mechanisms and exception handling, their effect on semantics and general program efficiency are also taken into account. Presented mechanisms were adopted to modern programming languages. Considering design area, formal methods and formal verification of program properties we can notice exception handling mechanisms are weakly present what makes a field for future research.

  4. Potential exposure to Australian bat lyssavirus is unlikely to prevent future bat handling among adults in South East Queensland.

    Science.gov (United States)

    Young, M K; Banu, S; McCall, B J; Vlack, S; Carroll, H; Bennett, S; Davison, R; Francis, D

    2018-02-01

    Despite ongoing public health messages about the risks associated with bat contact, the number of potential exposures to Australian bat lyssavirus (ABLV) due to intentional handling by members of the general public in Queensland has remained high. We sought to better understand the reasons for intentional handling among these members of the public who reported their potential exposure to inform future public health messages. We interviewed adults who resided in a defined geographic area in South East Queensland and notified potential exposure to ABLV due to intentional handling of bats by telephone between 1 January 2012 and 31 December 2013. The participation rate was 54%. Adults who reported they had intentionally handled bats in South East Queensland indicated high levels of knowledge and perception of a moderately high risk associated with bats with overall low intentions to handle bats in the future. However, substantial proportions of people would attempt to handle bats again in some circumstances, particularly to protect their children or pets. Fifty-two percent indicated that they would handle a bat if a child was about to pick up or touch a live bat, and 49% would intervene if a pet was interacting with a bat. Future public health communications should recognize the situations in which even people with highrisk perceptions of bats will attempt to handle them. Public health messages currently focus on avoidance of bats in all circumstances and recommend calling in a trained vaccinated handler, but messaging directed at adults for circumstances where children or pets may be potentially exposed should provide safe immediate management options. © 2017 Blackwell Verlag GmbH.

  5. The Potential Impact of Maintaining a 3-Hour IV Thrombolysis Window: How Many More Patients can we Safely Treat?

    Science.gov (United States)

    Lyerly, Michael J; Albright, Karen C; Boehme, Amelia K; Shahripour, Reza Bavarsad; Houston, James T; Rawal, Pawan V; Kapoor, Niren; Alvi, Muhammad; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2013-09-13

    In 2008, the European Cooperative Acute Stroke Study-3 (ECASS-3) demonstrated that intravenous-tissue plasminogen activator could be safely administered for acute stroke patients presenting between 3 and 4.5 hours from symptom onset. Recently, the Food and Drug Administration rejected expansion of this time window in the United States. We sought to determine how many fewer patients would be treated by maintaining this restricted time window. We reviewed charts from patients who received intravenous thrombolysis at the University of Alabama at Birmingham between January 2009 and December 2011. Patients were divided into two groups (treated within 3 hours of onset, treated between 3 and 4.5 hours from onset). Demographics, stroke severity and protocol deviations according to the ECASS-3 trial were collected. Our safety measures were any hemorrhagic transformation, symptomatic intracerebral hemorrhage and systemic hemorrhage. Two hundred and twelve patients were identified, of whom 192 were included in our analysis. A total of 36 patients (19%) were treated between 3 and 4.5 hours. No statistical differences were seen between age (p=0.633), gender (p=0.677), race (p=0.207) or admission stroke severity (p=0.737). Protocol deviations from the ECASS-3 criteria were found in 20 patients (56%). These were primarily age > 80 and aggressive blood pressure management. Despite these deviations, we did not see significant increases in the rates of adverse events in patients treated in the extended time window. Our data are consistent with previously reported international data that IV thrombolysis can safely be used up to 4.5 hours from symptom onset. Restricting the time window to 3 hours would have resulted in almost one-fifth fewer patients treated at our center.

  6. Laparoscopy is safe among patients with congestive heart failure undergoing general surgery procedures.

    Science.gov (United States)

    Speicher, Paul J; Ganapathi, Asvin M; Englum, Brian R; Vaslef, Steven N

    2014-08-01

    Over the past 2 decades, laparoscopy has been established as a superior technique in many general surgery procedures. Few studies, however, have examined the impact of the use of a laparoscopic approach in patients with symptomatic congestive heart failure (CHF). Because pneumoperitoneum has known effects on cardiopulmonary physiology, patients with CHF may be at increased risk. This study examines current trends in approaches to patients with CHF and effects on perioperative outcomes. The 2005-2011 National Surgical Quality Improvement Program Participant User File was used to identify patients who underwent the following general surgery procedures: Appendectomy, segmental colectomy, small bowel resection, ventral hernia repair, and splenectomy. Included for analysis were those with newly diagnosed CHF or chronic CHF with new signs or symptoms. Trends of use of laparoscopy were assessed across procedure types. The primary endpoint was 30-day mortality. The independent effect of laparoscopy in CHF was estimated with a multiple logistic regression model. A total of 265,198 patients were included for analysis, of whom 2,219 were identified as having new or recently worsened CHF. Of these patients, there were 1,300 (58.6%) colectomies, 486 (21.9%) small bowel resections, 216 (9.7%) ventral hernia repairs, 141 (6.4%) appendectomies, and 76 (3.4%) splenectomies. Laparoscopy was used less frequently in patients with CHF compared with their non-CHF counterparts, particularly for nonelective procedures. Baseline characteristics were similar for laparoscopy versus open procedures with the notable exception of urgent/emergent case status (36.4% vs 71.3%; P surgery procedures, particularly in urgent/emergent cases. Despite these patterns and apparent preferences, laparoscopy seems to offer a safe alternative in appropriately selected patients. Because morbidity and mortality were considerable regardless of approach, further understanding of appropriate management in this

  7. Iatrogenic Hepatitis C Virus Transmission and Safe Injection Practices.

    Science.gov (United States)

    Defendorf, Charles M; Paul, Sindy; Scott, George J

    2018-05-01

    Hepatitis C virus (HCV) infection poses significant adverse health effects. Improper use of vials, needles, syringes, intravenous bags, tubing, and connectors for injections and infusions is a current preventable cause of iatrogenic HCV transmission. Numerous cases have demonstrated the need for continued vigilance and the widespread nature of this iatrogenic infection risk across a variety of medical practice settings in the United States. Failure to implement the evidence-based Centers for Disease Control and Prevention (CDC) infection prevention guidelines exposes patients to preventable harm. The guidelines establish the requirement to notify patients in cases of suspected virus transmission, as well as to screen those patients who would not otherwise have been at risk for HCV seroconversion and other bloodborne pathogens. Legal and regulatory ramifications, including state, criminal, and tort laws, hold physicians and other health care professionals accountable to use safe injection practices. This article reviews the major health risks of HCV infection, significant effects of iatrogenic infection transmission, CDC guidelines for safe injection practices, and legal regulations and ramifications designed to promote safe injection practices.

  8. How safe is magnetic resonance imaging in patients with contraceptive implants

    International Nuclear Information System (INIS)

    Muehler, M.; Taupitz, M.

    2006-01-01

    When patients with an implanted contraceptive device undergo MRI, it must be ensured that the examination involves no risk to the patient (MR safety) and that the diagnosis is not affected by artifacts or the function of the device compromised (MR compatibility). Two basic types of intrauterine devices can be distinguished: the metal-containing/metal-free intrauterine device (IUD) and the hormone-containing implant, the fully metal-free intrauterine system (IUS), as well as the ESSURE insert made of stainless steel, which has been approved for use in Europe since February 2001. The metal-containing and metal-free IUDs and ESSURE are MRI compatible up to a magnetic field strength of 1.5 T. They do not interact in any relevant way with the external magnetic or high-frequency field and the temperature increase is within the physiologic range. The implants merely produce a local signal void with a shape that depends on their orientation relative to the magnetic field lines. At 3 T, only the metal-free IUD and the IUS are MRI safe in terms of the material used. In contrast, metal-containing IUDs and the ESSURE have not yet been fully evaluated in the 3 T field, which is why they represent a contraindication to MRI. No data are available on the MRI compatibility at 3 T for any of these devices. (orig.) [de

  9. Remote handling machines

    International Nuclear Information System (INIS)

    Sato, Shinri

    1985-01-01

    In nuclear power facilities, the management of radioactive wastes is made with its technology plus the automatic techniques. Under the radiation field, the maintenance or aid of such systems is important. To cope with this situation, MF-2 system, MF-3 system and a manipulator system as remote handling machines are described. MF-2 system consists of an MF-2 carrier truck, a control unit and a command trailer. It is capable of handling heavy-weight objects. The system is not by hydraulic but by electrical means. MF-3 system consists of a four-crawler truck and a manipulator. The truck is versatile in its posture by means of the four independent crawlers. The manipulator system is bilateral in operation, so that the delicate handling is made possible. (Mori, K.)

  10. Safe pediatric surgery: development and validation of preoperative interventions checklist

    Directory of Open Access Journals (Sweden)

    Maria Paula de Oliveira Pires

    2013-09-01

    Full Text Available OBJECTIVES: this study was aimed at developing and validating a checklist of preoperative pediatric interventions related to the safety of surgical patients. METHOD: methodological study concerning the construction and validation of an instrument with safe preoperative care indicators. The checklist was subject to validation through the Delphi technique, establishing a consensus level of 80%. RESULTS: five professional specialists in the area conducted the validation and a consensus on the content and the construct was reached after two applications of the Delphi technique. CONCLUSION: the "Safe Pediatric Surgery Checklist", simulating the preoperative trajectory of children, is an instrument capable of contributing to the preparation and promotion of safe surgery, as it identifies the presence or absence of measures required to promote patient safety.

  11. Well Connected, a platform for safe online communication and therapy

    NARCIS (Netherlands)

    Postel, Marloes Gerda; van Regteren, B.J.

    2012-01-01

    Well Connected, a platform for safe online communication and therapy Introduction Well Connected is a flexible, safe and user friendly e-health platform with a wide range of applications. Over the last 7 years 5000 patients were treated or a variety of addiction related problems. Besides creating an

  12. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    Science.gov (United States)

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  13. Cool and Safe: Multiplicity in Safe Innovation at Unilever

    Science.gov (United States)

    Penders, Bart

    2011-01-01

    This article presents the making of a safe innovation: the application of ice structuring protein (ISP) in edible ices. It argues that safety is not the absence of risk but is an active accomplishment; innovations are not "made safe afterward" but "safe innovations are made". Furthermore, there are multiple safeties to be accomplished in the…

  14. Influenza vaccination is safe and effective in patients suffering from fibromyalgia syndrome

    Directory of Open Access Journals (Sweden)

    J. N. Ablin

    2015-09-01

    Full Text Available The fibromyalgia syndrome (FMS is considered to result from the exposure of a genetically susceptible individual to various triggers, such as physical trauma, stress, viral infections etc. A possible role of vaccination in FMS etiology has been suspected. Our objective was to evaluate the efficacy and safety of influenza vaccination in FMS patients. Nineteen FMS patients underwent physical and dolorimetric examinations and answered the fibromyalgia impact questionnaire (FIQ, the widespread pain index (WPI checklist and the symptoms severity scale (SSS, which are part of the 2010 diagnostic criteria. Thirty-eight healthy subjects were recruited as controls. All participants were vaccinated with the inactivated split virion influenza vaccine. Serum was collected for antibody titration. Six weeks after vaccination, sera were tested by hemagglutination (HI against A/California (H1N1, A/Perth (H3N2 and B/Brisbane. Humoral response was defined as either a fourfold or greater increase in titer, or an increase from a non-protective baseline level of <1/40 to a level of 1/40. No severe vaccination reactions were observed. No significant change was observed between WPI, SSS and FIQ values before and after vaccination, indicating no worsening of FMS symptoms. Vaccine immunogenicity: Six weeks after vaccination, FMS patients showed a significant increase in geometric mean titers of HI antibody. The rates of sero-protection increased from 22.9% for H1N1 to 89.5% post-vaccination. A significant increase in HI antibody titers was also demonstrated among healthy controls. Influenza vaccination was both safe and effective in FMS patients. In view of these results, FMS patients should be encouraged to undergo influenza vaccination according to the standard WHO recommendations.

  15. Safety of Cargo Aircraft Handling Procedure

    Directory of Open Access Journals (Sweden)

    Daniel Hlavatý

    2017-07-01

    Full Text Available The aim of this paper is to get acquainted with the ways how to improve the safety management system during cargo aircraft handling. The first chapter is dedicated to general information about air cargo transportation. This includes the history or types of cargo aircraft handling, but also the means of handling. The second part is focused on detailed description of cargo aircraft handling, including a description of activities that are performed before and after handling. The following part of this paper covers a theoretical interpretation of safety, safety indicators and legislative provisions related to the safety of cargo aircraft handling. The fourth part of this paper analyzes the fault trees of events which might occur during handling. The factors found by this analysis are compared with safety reports of FedEx. Based on the comparison, there is a proposal on how to improve the safety management in this transportation company.

  16. Oral Surgical Procedures Performed Safely in Patients With Head and Neck Arteriovenous Malformations: A Retrospective Case Series of 12 Patients.

    Science.gov (United States)

    Karim, Abdul Basit; Lindsey, Sean; Bovino, Brian; Berenstein, Alejandro

    2016-02-01

    This case series describes patients with head and neck arteriovenous malformations who underwent oral and maxillofacial surgical procedures combined with interventional radiology techniques to minimize blood loss. Twelve patients underwent femoral cerebral angiography to visualize the extent of vascular malformation. Before the surgical procedures, surgical sites were devascularized by direct injection of hemostatic or embolic agents. Direct puncture sclerotherapy at the base of surgical sites was performed using Surgiflo or n-butylcyanoacrylate glue. Surgical procedures were carried out in routine fashion. A hemostatic packing of FloSeal, Gelfoam, and Avitene was adapted to the surgical sites. Direct puncture sclerotherapy with Surgiflo or n-butylcyanoacrylate glue resulted in minimal blood loss intraoperatively. Local application of the FloSeal, Gelfoam, and Avitene packing sustained hemostasis and produced excellent healing postoperatively. Patients with arteriovenous malformations can safely undergo routine oral and maxillofacial surgical procedures with minimal blood loss when appropriate endovascular techniques and local hemostatic measures are used by the interventional radiologist and oral and maxillofacial surgeon. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Simulator for candu600 fuel handling system. environmental implications

    International Nuclear Information System (INIS)

    Vulpe, S.; Valeca, S.; Predescu, D.

    2016-01-01

    Personnel training are a main topic in the security and reliability of several industrial processes. The simulator is a physical device that reproduces real operation of a device used in a production process technology. Typically, a simulator is intended to train the operators to work properly with the real device in the production process, but simulators can be involved frequently in the research and evaluation of performance of human operators. Process simulation has a significant role in the training of operators of nuclear plants. To ensure the safe operation, protection of workers and the environment, of any nuclear power plant, the training of its operators in all operating modes of the plant is essential. A trained operator who can handle any emergency in a controlled manner, without panic, protecting equipment and personnel is an asset for a nuclear power plant. (authors)

  18. Unique Chernobyl Cranes for Deconstruction Activities in the New Safe Confinement - 13542

    International Nuclear Information System (INIS)

    Parameswaran, N.A. Vijay; Chornyy, Igor; Owen, Rob; Schmieman, Eric; Kedrowski, Dan

    2013-01-01

    The devastation left behind from the Chernobyl nuclear power plant (ChNPP) Unit 4 accident which occurred on April 26, 1986 presented unparalleled technical challenges to the world engineering and scientific community. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter (OS) that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant (ChNPP) Unit. One of the major mechanical handling systems to be installed in the NSC is the Main Cranes System (MCS). The planned decontamination and decommissioning or dismantling (D and D) activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the NSC, will require large and sophisticated cranes. The article will focus on the unique design features of the MCS for the D and D activities. (authors)

  19. Unique Chernobyl Cranes for Deconstruction Activities in the New Safe Confinement - 13542

    Energy Technology Data Exchange (ETDEWEB)

    Parameswaran, N.A. Vijay [Bechtel Systems and Infrastructure, Inc. (United States); Chornyy, Igor [Chernobyl NPP-SIP-PMU (Ukraine); Owen, Rob [PaR Systems, Inc. (United States); Schmieman, Eric [Battelle Memorial Institute (United States); Kedrowski, Dan

    2013-07-01

    The devastation left behind from the Chernobyl nuclear power plant (ChNPP) Unit 4 accident which occurred on April 26, 1986 presented unparalleled technical challenges to the world engineering and scientific community. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter (OS) that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant (ChNPP) Unit. One of the major mechanical handling systems to be installed in the NSC is the Main Cranes System (MCS). The planned decontamination and decommissioning or dismantling (D and D) activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the NSC, will require large and sophisticated cranes. The article will focus on the unique design features of the MCS for the D and D activities. (authors)

  20. Can patient involvement improve patient safety? A cluster randomised control trial of the Patient Reporting and Action for a Safe Environment (PRASE) intervention.

    Science.gov (United States)

    Lawton, Rebecca; O'Hara, Jane Kathryn; Sheard, Laura; Armitage, Gerry; Cocks, Kim; Buckley, Hannah; Corbacho, Belen; Reynolds, Caroline; Marsh, Claire; Moore, Sally; Watt, Ian; Wright, John

    2017-08-01

    To evaluate the efficacy of the Patient Reporting and Action for a Safe Environment intervention. A multicentre cluster randomised controlled trial. Clusters were 33 hospital wards within five hospitals in the UK. All patients able to give informed consent were eligible to take part. Wards were allocated to the intervention or control condition. The ward-level intervention comprised two tools: (1) a questionnaire that asked patients about factors contributing to safety (patient measure of safety (PMOS)) and (2) a proforma for patients to report both safety concerns and positive experiences (patient incident reporting tool). Feedback was considered in multidisciplinary action planning meetings. Primary outcomes were routinely collected ward-level harm-free care (HFC) scores and patient-level feedback on safety (PMOS). Intervention uptake and retention of wards was 100% and patient participation was high (86%). We found no significant effect of the intervention on any outcomes at 6 or 12 months. However, for new harms (ie, those for which the wards were directly accountable) intervention wards did show greater, though non-significant, improvement compared with control wards. Analyses also indicated that improvements were largest for wards that showed the greatest compliance with the intervention. Adherence to the intervention, particularly the implementation of action plans, was poor. Patient safety outcomes may represent too blunt a measure. Patients are willing to provide feedback about the safety of their care. However, we were unable to demonstrate any overall effect of this intervention on either measure of patient safety and therefore cannot recommend this intervention for wider uptake. Findings indicate promise for increasing HFC where wards implement ≥75% of the intervention components. ISRCTN07689702; pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Midas® Fumigant Safe Handling Guide

    Science.gov (United States)

    Handlers or applicators should wear personal protective equipment including respirator and chemical-resistant gloves when working with this soil fumigant, be trained according to the Worker Protection Standard (WPS), and know signs of pesticide exposure.

  2. How to Handle Abuse

    Science.gov (United States)

    ... Handle Abuse KidsHealth / For Kids / How to Handle Abuse What's in this article? Tell Right Away How Do You Know Something Is Abuse? ... babysitter, teacher, coach, or a bigger kid. Child abuse can happen anywhere — at ... building. Tell Right Away A kid who is being seriously hurt ...

  3. Extracorporeal shock wave lithotripsy is safe and effective for pediatric patients with chronic pancreatitis.

    Science.gov (United States)

    Wang, Dan; Bi, Ya-Wei; Ji, Jun-Tao; Xin, Lei; Pan, Jun; Liao, Zhuan; Du, Ting-Ting; Lin, Jin-Huan; Zhang, Di; Zeng, Xiang-Peng; Ye, Bo; Zou, Wen-Bin; Chen, Hui; Xie, Ting; Li, Bai-Rong; Zheng, Zhao-Hong; Li, Zhao-Shen; Hu, Liang-Hao

    2017-05-01

    Background and aims  Pancreatic extracorporeal shock wave lithotripsy (P-ESWL) is recommended as the first-line treatment for pancreatic stones. However, how well P-ESWL performs in pediatric patients remains unclear. We aimed to evaluate the safety and efficacy of P-ESWL for pediatric patients with chronic pancreatitis. Methods  This prospective observational study was conducted in patients with painful chronic pancreatitis who underwent P-ESWL. Patients aged under 18 years were included in the pediatric group; patients aged over 18 years who underwent P-ESWL in the same period were assigned to the control group. For investigation of long-term follow-up, the pediatric group were matched with patients from the control group in a 1:1 ratio. The primary outcomes were P-ESWL complications and pain relief. The secondary outcomes included: stone clearance, physical and mental health, quality of life score, and growth and developmental state. Results  From March 2011 to March 2015, P-ESWL was performed in 1135 patients (72 in the pediatric group, 1063 in the control group). No significant differences were observed in the occurrence of P-ESWL complications between the two groups (11.1 % vs. 12.8 %; P  = 0.68). Among the 67 pediatric patients (93.1 %) who underwent follow-up for 3.0 years (range 1.3 - 5.2), complete pain relief was achieved in 52 patients (52 /67; 77.6 %); this value was not significantly different from that of the matched controls (55 /69; 79.7 %; P  = 0.94). Conclusions  P-ESWL is safe and effective for pediatric patients with chronic pancreatitis. It can promote significant pain relief and stone clearance, and can benefit growth and development. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Waste Handling Building Conceptual Study

    International Nuclear Information System (INIS)

    G.W. Rowe

    2000-01-01

    The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options Report'', which will address the overall program objectives and direction, including options and issues associated with transportation, the subsurface facility, and Total System Life Cycle Cost. This study (herein) is limited to the Waste Handling System and associated fuel staging system

  5. Practices of Handling

    DEFF Research Database (Denmark)

    Ræbild, Ulla

    to touch, pick up, carry, or feel with the hands. Figuratively it is to manage, deal with, direct, train, or control. Additionally, as a noun, a handle is something by which we grasp or open up something. Lastly, handle also has a Nordic root, here meaning to trade, bargain or deal. Together all four...... meanings seem to merge in the fashion design process, thus opening up for an embodied engagement with matter that entails direction giving, organizational management and negotiation. By seeing processes of handling as a key fashion methodological practice, it is possible to divert the discourse away from...... introduces four ways whereby fashion designers apply their own bodies as tools for design; a) re-activating past garment-design experiences, b) testing present garment-design experiences c) probing for new garment-design experiences and d) design of future garment experiences by body proxy. The paper...

  6. Safe management of wastes from the mining and milling of uranium and thorium ores

    International Nuclear Information System (INIS)

    1987-01-01

    Wastes from the mining and milling of uranium and thorium ores pose potential environmental and public health problems because of their radioactivity and chemical composition. This document consists of two parts: a Code of Practice (Part I) and a Guide to the Code (Part II). The Code sets forth the requirements for the safe and responsible handling of the wastes resulting from the mining and milling of uranium and thorium ores, while the Guide presents further guidance in the use of the Code together with some discussion of the technology and concepts involved

  7. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  8. Patients’ experience on complaint handling; a comparison between Complaint Committees and Disciplinary Boards.

    NARCIS (Netherlands)

    Kruikemeier, S.; Coppen, R.; Friele, R.D.

    2009-01-01

    Background: Handling patient complaints about health care issues is important. However, many patients who lodge a complaint are dissatisfied with the way their complaints are dealt with. In the Netherlands, there are two institutions to lodge a complaint: the Complaints Committee and the

  9. Grain Handling and Storage.

    Science.gov (United States)

    Harris, Troy G.; Minor, John

    This text for a secondary- or postecondary-level course in grain handling and storage contains ten chapters. Chapter titles are (1) Introduction to Grain Handling and Storage, (2) Elevator Safety, (3) Grain Grading and Seed Identification, (4) Moisture Control, (5) Insect and Rodent Control, (6) Grain Inventory Control, (7) Elevator Maintenance,…

  10. Preemptive intravenous immunoglobulin allows safe and timely administration of antineoplastic therapies in patients with multiple myeloma and parvovirus B19 disease.

    Science.gov (United States)

    Katragadda, L; Shahid, Z; Restrepo, A; Muzaffar, J; Alapat, D; Anaissie, E

    2013-08-01

    Parvovirus B19 (B19) disease is a rare cause of anemia in cancer patients and often goes unrecognized, causing delays in anticancer therapy. A retrospective review was carried out of the records of patients with multiple myeloma who underwent melphalan-based autologous stem cell transplantation (MEL-ASCT) and developed B19 infection (January 2009-December 2011). Cases were defined by the presence of clinical and laboratory findings consistent with B19 disease in patients with repeatedly positive plasma quantitative polymerase chain reaction for parvovirus. Six patients qualified as cases; 5 presented with trilineage cytopenias (chronic in 1) and 1 with anemia later progressing to pancytopenia. Transfusion-dependent thrombocytopenia led to testing in 5 patients. Two of these patients also had manifestations of autoimmune disease. Therapy with intravenous immunoglobulin (IVIG) resulted in clinical and hematologic response in all; however, 1 patient, whose white blood cell counts and serum hemoglobin levels improved, required splenectomy for persistent thrombocytopenia. All patients required additional IVIG for recurrent B19 disease. Although viral load at diagnosis did not correlate with the severity of cytopenia, its decrease was associated with response during 17 of 20 evaluable episodes (P = 0.02). Preemptive IVIG allowed the safe administration of chemotherapy in 3 patients, including MEL-ASCT in 1. Parvovirus B19 can cause severe disease in myeloma patients including ASCT recipients. Thrombocytopenia - not anemia - was the leading presentation and may be associated with autoimmune conditions. Patients with unexplained cytopenias, particularly when prolonged, should undergo testing for circulating parvovirus. A reduction in viral load was associated with response to IVIG, although additional therapy was needed for recurrent disease. Most importantly, preemptive IVIG allowed for safe and timely administration of antineoplastic therapy in patients with ongoing B

  11. TRANSPORT/HANDLING REQUESTS

    CERN Multimedia

    Groupe ST/HM

    2002-01-01

    A new EDH document entitled 'Transport/Handling Request' will be in operation as of Monday, 11th February 2002, when the corresponding icon will be accessible from the EDH desktop, together with the application instructions. This EDH form will replace the paper-format transport/handling request form for all activities involving the transport of equipment and materials. However, the paper form will still be used for all vehicle-hire requests. The introduction of the EDH transport/handling request form is accompanied by the establishment of the following time limits for the various services concerned: 24 hours for the removal of office items, 48 hours for the transport of heavy items (of up to 6 metric tons and of standard road width), 5 working days for a crane operation, extra-heavy transport operation or complete removal, 5 working days for all transport operations relating to LHC installation. ST/HM Group, Logistics Section Tel: 72672 - 72202

  12. Keeping patients safe in healthcare organizations: a structuration theory of safety culture.

    Science.gov (United States)

    Groves, Patricia S; Meisenbach, Rebecca J; Scott-Cawiezell, Jill

    2011-08-01

    This paper presents a discussion of the use of structuration theory to facilitate understanding and improvement of safety culture in healthcare organizations. Patient safety in healthcare organizations is an important problem worldwide. Safety culture has been proposed as a means to keep patients safe. However, lack of appropriate theory limits understanding and improvement of safety culture. The proposed structuration theory of safety culture was based on a critique of available English-language literature, resulting in literature published from 1983 to mid-2009. CINAHL, Communication and Mass Media Complete, ABI/Inform and Google Scholar databases were searched using the following terms: nursing, safety, organizational culture and safety culture. When viewed through the lens of structuration theory, safety culture is a system involving both individual actions and organizational structures. Healthcare organization members, particularly nurses, share these values through communication and enact them in practice, (re)producing an organizational safety culture system that reciprocally constrains and enables the actions of the members in terms of patient safety. This structurational viewpoint illuminates multiple opportunities for safety culture improvement. Nurse leaders should be cognizant of competing value-based culture systems in the organization and attend to nursing agency and all forms of communication when attempting to create or strengthen a safety culture. Applying structuration theory to the concept of safety culture reveals a dynamic system of individual action and organizational structure constraining and enabling safety practice. Nurses are central to the (re)production of this safety culture system. © 2011 Blackwell Publishing Ltd.

  13. Is ciprofloxacin safe in patients with solitary kidney and upper urinary tract infection?

    Science.gov (United States)

    Gluhovschi, Gheorghe; Gadalean, Florica; Gluhovschi, Cristina; Velciov, Silvia; Petrica, Ligia; Bob, Flaviu; Bozdog, Gheorghe; Kaycsa, Adriana

    2016-12-01

    susceptibility). In SK patients, renal tubular biomarkers, especially NAG, allow monitoring of tubular injury and impose caution in prescribing ciprofloxacin treatment, mainly to patients at risk. Ciprofloxacin is relatively safe regarding its nephrotoxicity, while caution is required in vulnerable patients. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. The SafeCOP ECSEL Project: Safe Cooperating Cyber-Physical Systems Using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Hansson, Hans

    2016-01-01

    This paper presents an overview of the ECSEL project entitled "Safe Cooperating Cyber-Physical Systems using Wireless Communication" (SafeCOP), which runs during the period 2016 -- 2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  15. Cask system design guidance for robotic handling

    International Nuclear Information System (INIS)

    Griesmeyer, J.M.; Drotning, W.D.; Morimoto, A.K.; Bennett, P.C.

    1990-10-01

    Remote automated cask handling has the potential to reduce both the occupational exposure and the time required to process a nuclear waste transport cask at a handling facility. The ongoing Advanced Handling Technologies Project (AHTP) at Sandia National Laboratories is described. AHTP was initiated to explore the use of advanced robotic systems to perform cask handling operations at handling facilities for radioactive waste, and to provide guidance to cask designers regarding the impact of robotic handling on cask design. The proof-of-concept robotic systems developed in AHTP are intended to extrapolate from currently available commercial systems to the systems that will be available by the time that a repository would be open for operation. The project investigates those cask handling operations that would be performed at a nuclear waste repository facility during cask receiving and handling. The ongoing AHTP indicates that design guidance, rather than design specification, is appropriate, since the requirements for robotic handling do not place severe restrictions on cask design but rather focus on attention to detail and design for limited dexterity. The cask system design features that facilitate robotic handling operations are discussed, and results obtained from AHTP design and operation experience are summarized. The application of these design considerations is illustrated by discussion of the robot systems and their operation on cask feature mock-ups used in the AHTP project. 11 refs., 11 figs

  16. Code of practice for the safe use of industrial radiography equipment (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    This code supersedes the Code of Practice for the control and safe handling of sealed radioactive sources use din industrial radiography, published by the National Health and Medical Research Council (NHMRC) in 1968. It differs significantly from the former code because radiation protection practice and recommended standards have changed. The code covers the design, construction and requirements for the safe use of X-radiography equipment and gamma-radiography equipment. It provides illustrative working rules, detailed emergency procedures and comprehensive responsibilities and duties for all personnel involved in supplying and using industrial radiography equipment. The code details those equipment requirements, personnel requirements and work practices that the NHMRC considers necessary to keep exposures to ionizing radiation as low as reasonably achievable. Some equipment and facilities currently in use may not meet all of the mandatory requirements of this code. These requirements have been included in the code to encourage progress towards future compliance in the expectation that, in the interim, statutory authorities will apply them with discretion. 9 refs., tabs., ills

  17. Regional anesthesia is safe and effective for lower limb orthopedic surgery in patient with renal tubular acidosis and hypokalemia

    Directory of Open Access Journals (Sweden)

    Indira Gurajala

    2018-01-01

    Full Text Available Renal tubular acidosis (RTA with hypokalemia may precipitate acute respiratory failure and potentially fatal arrhythmias like ventricular fibrillation. Though there are random reports of respiratory failure needing mechanical ventilation and sudden death in patients with RTA and hypokalemia, the anesthetic management of these patients has not been clearly elucidated. Acidosis and hypokalemia have significant interactions with both general and local anesthetics and alter their effect substantially. Proper preoperative planning and optimization are required for the safe conduct of anesthesia in this subset of patients. We describe a case of distal RTA, hypokalemia, and metabolic bone disease in whom central neuraxial anesthesia was effectively used for lower limb orthopedic surgery with no complications.

  18. Production management of window handles

    Directory of Open Access Journals (Sweden)

    Manuela Ingaldi

    2014-12-01

    Full Text Available In the chapter a company involved in the production of aluminum window and door handles was presented. The main customers of the company are primarily companies which produce PCV joinery and wholesalers supplying these companies. One chosen product from the research company - a single-arm pin-lift window handle - was described and its production process depicted technologically. The chapter also includes SWOT analysis conducted in the research company and the value stream of the single-arm pin-lift window handle.

  19. 7 CFR 58.443 - Whey handling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Whey handling. 58.443 Section 58.443 Agriculture... Procedures § 58.443 Whey handling. (a) Adequate sanitary facilities shall be provided for the handling of whey. If outside, necessary precautions shall be taken to minimize flies, insects and development of...

  20. Safe Kids Worldwide

    Science.gov (United States)

    ... Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters Who We Are What We Do Find Your Safe Kids Safe Kids Day Main menu Keeping All Kids Safe Safety Tips Get Involved 4 Star Charity Donate Text Burns and Scalds 4 tips ...

  1. Development of commercial robots for radwaste handling

    International Nuclear Information System (INIS)

    Colborn, K.A.

    1988-01-01

    The cost and dose burden associated with low level radwaste handling activities is a matter of increasing concern to the commercial nuclear power industry. This concern is evidenced by the fact that many utilities have begun to revaluate waste generation, handling, and disposal activities at their plants in an effort to improve their overall radwaste handling operations. This paper reports on the project Robots for Radwaste Handling, to identify the potential of robots to improve radwaste handling operations. The project has focussed on the potential of remote or automated technology to improve well defined, recognizable radwaste operations. The project focussed on repetitive, low skill level radwaste handling and decontamination tasks which involve significant radiation exposure

  2. Feeling safe and motivated to achieve better health: Experiences with a partnership-based nursing practice programme for in-home patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Leine, Marit; Wahl, Astrid Klopstad; Borge, Christine Råheim; Hustavenes, Magne; Bondevik, Hilde

    2017-09-01

    To explore chronic obstructive pulmonary disease patients' experiences with a partnership-based nursing practice programme in the home setting. Patients with chronic obstructive pulmonary disease suffer from psychological and physiological problems, especially when they return home after hospitalisation from exacerbation. Many express a need for information and knowledge about chronic obstructive pulmonary disease. Partnership as practice is a patient-centred framework providing an individualised practice for each patient. This study intends to achieve a nuanced and improved understanding of chronic obstructive pulmonary disease patients' experiences with a partnership-based nursing practice programme comprising home visits from a respiratory nurse after hospital discharge, alongside interdisciplinary collaboration. This study has a qualitative design with interviews. Six individual semi-structured interviews collected in 2012-2013 constitute the material. Interviews were recorded, transcribed to written text and analysed using systematic text condensation. Three key themes were identified: to be seen, talked with and understood; healthcare support at home-continuity, practical support and facilitation; and exchange of knowledge. However, there were two generic themes that permeated the material: feeling safe and comforted, and motivation to achieve better health. Patients with chronic obstructive pulmonary disease can experience feeling safe and comforted, and be motivated to make changes in order to achieve better health after participating in a partnership-based nursing practice programme that includes home visits from a respiratory nurse and interdisciplinary cooperation after hospital discharge. To feel safe is of great importance, and how this relates to the patient's ability to cope with illness should be explored in further research. The results suggest that the partnership-based nursing practice programme that includes home visits and interdisciplinary

  3. Can Type 1 Diabetes patients safely fast during Ramadan?

    Directory of Open Access Journals (Sweden)

    M. Hamed Farooqi

    2016-09-01

    Full Text Available The issue whether people with Type 1 Diabetes can safely fast during Ramadan has been the subject of quite a few debates over the years. Had it been a simple "yes" or "no" issue, there would have been no reason to debate. However, like a lot of other topics in medical management, this particular subject overlaps both the science and the art of medicine.

  4. Simplified swift and safe vascular closure device deployment without a local arteriogram: Single center experience in 2074 consecutive patients

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis

    2016-07-01

    Conclusion: Deployment of Angio-Seal without use of local angiography was efficacious and safe, characterized by a high success rate of deployment and hemostasis with few correctable complications in a large patient cohort undergoing transfemoral catheterization for PCI and non-PCI procedures under anticoagulation and antiplatelet drug therapy. VCD reduced the time-to-hemostasis and time-to-mobilization and minimized the incidence of complications.

  5. Preoperational checkout of the remote-handled transuranic waste handling at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    1987-09-01

    This plan describes the preoperational checkout for handling Remote-Handled Transuranic (RH-TRU) Wastes from their receipt at the Waste Isolation Pilot Plant (WIPP) to their emplacement underground. This plan identifies the handling operations to be performed, personnel groups responsible for executing these operations, and required equipment items. In addition, this plan describes the quality assurance that will be exercised throughout the checkout, and finally, it establishes criteria by which to measure the success of the checkout. 7 refs., 5 figs

  6. Patients’ handling of a standardized medication plan: a pilot study and method development

    Directory of Open Access Journals (Sweden)

    Botermann L

    2016-04-01

    Full Text Available Lea Botermann,1,2 Katrin Krueger,1 Christiane Eickhoff,1 Charlotte Kloft,2 Martin Schulz1–31Department of Medicine, ABDA – Federal Union of German Associations of Pharmacists, Berlin, 2Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Berlin, 3Department of Pharmacology, Goethe-University Frankfurt, Frankfurt am Main, GermanyPurpose: The Action Plan for Medication Safety by the German Federal Ministry of Health introduced a standardized medication plan (MP, a printable document for the patient. The practical handling needs to be tested before the nationwide implementation in Germany. Therefore, the aims of our study were 1 to develop an instrument to evaluate the usage of the standardized MP, 2 to assess if patients can locate, and 3 understand important information. Moreover, we explored patients’ opinion and suggestions regarding the standardized MP template.Patients and methods: We conducted a cross-sectional study to evaluate the practical handling of the standardized MP. We interviewed 40 adult patients in seven community pharmacies in Germany, who took at least five medicines regularly and gave their written informed consent. The interview consisted of questions regarding finding and understanding information provided on a mock-up MP, patients’ opinion and the execution of the information on the MP by filling pill boxes. We eventually developed a new evaluation method to quantify the practical handling of the MP by rating the pill boxes filled by the patients.Results: Overall, the participants rated the MP positively. Thirty-nine (98% participants found important information on a mock-up standardized MP. Patients were questioned to identify if they understood information on medical intake as it relates to meals. In particular, they were questioned about medicine intake “1 hour before a meal”, which 98% (n=39 interpreted correctly, and “during a meal”, which 100% (n=40

  7. Nonspecific abdominal pain is a safe diagnosis.

    Science.gov (United States)

    Pennel, David John Laurie; Goergen, Nina; Driver, Chris P

    2014-11-01

    The aim of this study is to assess if a clinical diagnosis of nonspecific abdominal pain (NSAP) is safe and if patients with this initial diagnosis are likely to require further investigation or surgical intervention. 3323 patients admitted with NSAP from July 1990 to September 2012 utilizing a prospective database of all surgical admissions were included. Readmission over the period of the study and specifically within 30 days of their initial presentation was identified together with any invasive investigation or surgical intervention. 319 children (9.6%) were subsequently readmitted with abdominal pain at some point during the study period. Of these, 78 (2.3%) were readmitted within 30 days. 118 (3.5%) children subsequently had an operation or invasive investigation some point following their initial admission. Of these 33 (0.6%) had the procedure within 3 months of the initial admission. 13 patients had an appendicectomy within 3 months of the initial presentation. Of these histology confirmed appendicitis in 8 patients. This gives an overall incidence of "missed" appendicitis of 0.2 % (8/3323). This study confirms that a clinical diagnosis of nonspecific abdominal pain (NSAP) is safe in a pediatric population and the risk of "missing" appendicitis is only 0.2%. Patients and/or parents can be confidently reassured that the risk of missing organic pathology is very low. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Preference Handling for Artificial Intelligence

    OpenAIRE

    Goldsmith, Judy; University of Kentucky; Junker, Ulrich; ILOG

    2009-01-01

    This article explains the benefits of preferences for AI systems and draws a picture of current AI research on preference handling. It thus provides an introduction to the topics covered by this special issue on preference handling.

  9. Religious Serpent Handling and Community Relations.

    Science.gov (United States)

    Williamson, W Paul; Hood, Ralph W

    2015-01-01

    Christian serpent handling sects of Appalachia comprise a community that has long been mischaracterized and marginalized by the larger communities surrounding them. To explore this dynamic, this article traces the emergence of serpent handling in Appalachia and the emergence of anti-serpent-handling state laws, which eventually failed to curb the practice, as local communities gave serpent handling groups support. We present two studies to consider for improving community relations with serpent handling sects. In study 1, we present data relating the incidence of reported serpent-bite deaths with the rise of anti-serpent-handling laws and their eventual abatement, based on increasing acceptance of serpent handlers by the larger community. Study 2 presents interview data on serpent bites and death that provide explanations for these events from the cultural and religious perspective. We conclude that first-hand knowledge about serpent handlers, and other marginalized groups, helps to lessen suspicion and allows them to be seen as not much different, which are tendencies that are important for promoting inter-community harmony.

  10. Safe Driving After Propofol Sedation.

    Science.gov (United States)

    Summerlin-Grady, Lee; Austin, Paul N; Gabaldon, Dion A

    2017-10-01

    Propofol is a short-acting medication with fast cognitive and psychomotor recovery. However, patients are usually instructed not to drive a motor vehicle for 24 hours after receiving propofol. The purpose of this article was to review the evidence examining when it is safe to drive after receiving propofol for sedation for diagnostic and surgical procedures. This is a systematic review of the literature. A search of the literature was conducted using Google Scholar, PubMed, and the Cochrane Library for the time period 1990 to 2015. Two randomized controlled trials and two observational studies met the inclusion criteria. Using a simulator, investigators examined driving ability of subjects who received modest doses (about 100 mg) of propofol for endoscopic procedures and surveyed subjects who drove immediately after discharge. There were methodological concerns with the studies such as small sample sizes, modest doses of propofol, and three of the four studies were done in Japan by the same group of investigators limiting generalizability. This limited research suggests that it may be safe for patients to drive sooner than 24 hours after receiving propofol. However, large multicenter trials using heterogenous samples using a range of propofol doses are needed to support an evidence-based revision to the current discharge guidelines for patients receiving propofol. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  11. How Fatigue Is Experienced and Handled by Female Outpatients with Inflammatory Bowel Disease

    Directory of Open Access Journals (Sweden)

    Anne Beck

    2013-01-01

    Full Text Available Background. Fatigue is a significant aspect of everyday life for patients with inflammatory bowel disease (IBD, and it influences their health-related quality of life. Little is known about fatigue from the patient’s perspective. Aim. To investigate how female IBD patients experience and handle fatigue. Methods. The study included 11 female outpatients. These patients were 40–59 years old and had IBD ≥ one year and a significantly increased fatigue score. Patients with severe active IBD, anaemia, comorbidity, or pregnancy were excluded. The included patients agreed to participate in a semistructured interview. The interviews were analysed using Malterud’s principles of systematic text condensation. Results. The patients described physical and mental symptoms of fatigue that led to social-, physical-, and work-related limitations with emotional consequences. To handle fatigue, the patients used planning, priority, acceptance, exercise, and support. Two of the eleven patients used exercise on a regular basis. Surprisingly, some patients indicated that they did not need to talk with professionals about their fatigue unless a cure was available. Conclusion. Fatigue in IBD includes physical and mental symptoms that limit the patients’ social-, physical-, and work-related lives. Despite this, some patients expressed that they had chosen to accept their fatigue.

  12. Anatomical Basis for Safe and Effective Volumization of the Temple.

    Science.gov (United States)

    Breithaupt, Andrew D; Jones, Derek H; Braz, Andre; Narins, Rhoda; Weinkle, Susan

    2015-12-01

    One of the earliest but often unaddressed signs of facial aging is volume loss in the temple. Treatment of the area can produce satisfying results for both patient and practitioner. Safe injection requires explicit knowledge of the anatomy to avoid complications related to the multitude of vessels that course throughout the region at various depths. The authors aim to detail the anatomy of the area and provide a safe and easy-to-follow method for injection. The authors review the relevant anatomy of the temporal region and its application to cosmetic filler injections. The authors describe an easy-to-follow approach for a safe and effective injection window based on numerous anatomical studies. Injection in this area is not without risk, including potential blindness. The authors review the potential complications and their treatments. Hollowing of the temple is an early sign of aging that, when corrected, can lead to significant patient and practitioner satisfaction. Proper anatomically knowledge is required to avoid potentially severe complications. In this study, the authors present a reliable technique to safely and effectively augment this often undertreated area of the aging face.

  13. Positioning of the patient during shoulder surgery: an inexpensive, safe and easy technique.

    Science.gov (United States)

    Van Tongel, Alexander; Hardeman, François; Karelse, Anne; de Wilde, Lieven

    2013-01-01

    The knowledge of shoulder pathology has improved tremendously in the last decades, and shoulder surgery is increasingly performed because of new treatment options and better operative results. Nowadays most surgical shoulder procedures are performed in the sitting or semi-sitting (beach chair) position. Stability of the patient and the ability to flex, extend and rotate the shoulder during surgery are crucial to improve exposure of the surgical field and lower the risk of perioperative complications. We developed an easy, safe and inexpensive surgical set-up providing a very good posterior, superior and anterior access to the shoulder in the sitting or semi-sitting position. In this technique, the patient is placed supine with the head at the foot end of the table and the body positioned slightly eccentrically with the back being supported by the leg plate contralateral to the operative side, avoiding any contact with the scapula of the operative side. A neck support is attached on an extra bar at the contralateral side and accommodated to the patient's lordosis. Next, the leg plate on the operative side is removed, and the head and the body are secured to the table with adhesive dressing. This way a stable positioning of the patient is obtained during the whole procedure, and the shoulder girdle is completely free. The set-up can accommodate patients of different stature and weight without the need to adapt the technique. This position also gives the possibility to provide an excellent radiographic view of the shoulder during operative fracture treatment. Our technique further allows a significant reduction in costs. A surgical table, extra bar, additional arm support and neck support are usually available and can be used in different settings, without the need for a specific shoulder table.

  14. How Retailers Handle Complaint Management

    DEFF Research Database (Denmark)

    Hansen, Torben; Wilke, Ricky; Zaichkowsky, Judy

    2009-01-01

    This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained as to the......This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained...... as to the links between CM and redress of consumers’ complaints. The results suggest that retailers who attach large negative consequences to consumer dissatisfaction are more likely than other retailers to develop a positive strategic view on customer complaining, but at the same time an increase in perceived...

  15. 7 CFR 926.9 - Handle.

    Science.gov (United States)

    2010-01-01

    ... the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE DATA COLLECTION, REPORTING AND RECORDKEEPING REQUIREMENTS APPLICABLE TO CRANBERRIES NOT SUBJECT TO THE CRANBERRY MARKETING ORDER § 926.9 Handle. Handle...

  16. Regulatory Framework and Current Practices of the Radioactive Material Safe and Secure Transport in Albania

    International Nuclear Information System (INIS)

    Dollani, K.; Grillo, B.; Telhaj, E.

    2016-01-01

    Attempts for the establishing of a safe and secure radioactive material transport in Albania began a decade ago with formulation of the different regulation in the field of safe and secure handling of the radioactive materials. In 2004 a special regulation for the safe transport of radioactive material was prepared and approved by the National Radiation Protection Commission). This regulation has been based in the IAEA standards for the radioactive material transport and was reviewed periodically. The last regulation of the radioactive material transport was approved by Albanian government through a governmental ordinance. The transport of the radioactive material in Albania is performed by licensed subjects, which fulfill all requirements of the mentioned governmental ordinance. Based in the existing regulation, for each transport of radioactive material, a special permission is issued by NRPC. The issuing of permission allows competent authority to provide necessary information on transport regularity and to have under survey all transports of the radioactive material carried out inside the country. Last year were issued more than 80 permissions for the transport of the different types and categories of the radioactive sources. (author)

  17. Higher Caloric Refeeding Is Safe in Hospitalised Adolescent Patients with Restrictive Eating Disorders

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Parker

    2016-01-01

    Full Text Available Introduction. This study examines weight gain and assesses complications associated with refeeding hospitalised adolescents with restrictive eating disorders (EDs prescribed initial calories above current recommendations. Methods. Patients admitted to an adolescent ED structured “rapid refeeding” program for >48 hours and receiving ≥2400 kcal/day were included in a 3-year retrospective chart review. Results. The mean (SD age of the 162 adolescents was 16.7 years (0.9, admission % median BMI was 80.1% (10.2, and discharge % median BMI was 93.1% (7.0. The mean (SD starting caloric intake was 2611.7 kcal/day (261.5 equating to 58.4 kcal/kg (10.2. Most patients (92.6% were treated with nasogastric tube feeding. The mean (SD length of stay was 3.6 weeks (1.9, and average weekly weight gain was 2.1 kg (0.8. No patients developed cardiac signs of RFS or delirium; complications included 4% peripheral oedema, 1% hypophosphatemia (<0.75 mmol/L, 7% hypomagnesaemia (<0.70 mmol/L, and 2% hypokalaemia (<3.2 mmol/L. Caloric prescription on admission was associated with developing oedema (95% CI 1.001 to 1.047; p=0.039. No statistical significance was found between electrolytes and calories provided during refeeding. Conclusion. A rapid refeeding protocol with the inclusion of phosphate supplementation can safely achieve rapid weight restoration without increased complications associated with refeeding syndrome.

  18. Safely prolonging single breath-holds to >5 min in patients with cancer; feasibility and applications for radiotherapy

    Science.gov (United States)

    Green, Stuart; Stevens, Andrea M; Parveen, Sophia; Stephens, Rebecca; Clutton-Brock, Thomas H

    2016-01-01

    Objective: Multiple, short and deep inspiratory breath-holds with air of approximately 20 s are now used in radiotherapy to reduce the influence of ventilatory motion and damage to healthy tissue. There may be further clinical advantages in delivering each treatment session in only one single, prolonged breath-hold. We have previously developed techniques enabling healthy subjects to breath-hold for 7 min. Here, we demonstrate their successful application in patients with cancer. Methods: 15 patients aged 37–74 years undergoing radiotherapy for breast cancer were trained to breath-hold safely with pre-oxygenation and mechanically induced hypocapnia under simulated radiotherapy treatment conditions. Results: The mean breath-hold duration was 5.3 ± 0.2 min. At breakpoint, all patients were normocapnic and normoxic [mean end-tidal partial pressure of carbon dioxide was 36 ± 1 standard error millimetre of mercury, (mmHg) and mean oxygen saturation was 100 ± 0 standard error %]. None were distressed, nor had gasping, dizziness or disturbed breathing in the post-breath-hold period. Mean blood pressure had risen significantly from 125 ± 3 to 166 ± 4 mmHg at breakpoint (without heart rate falling), but normalized within approximately 20 s of the breakpoint. During breath-holding, the mean linear anteroposterior displacement slope of the L breast marker was radiotherapy treatment conditions for longer than the typical beam-on time of a single fraction. We discuss the important applications of this technique for radiotherapy. Advances in knowledge: We demonstrate for the first time a technique enabling patients with cancer to deliver safely a single prolonged breath-hold of >5 min (10 times longer than currently used in radiotherapy practice), under simulated radiotherapy treatment conditions. PMID:27168468

  19. INFLUENCE OF IMMUNOLOGICAL DISORDERS ON AN OUTCOME FOR THE FIRST TIME DIAGNOSED INFILTRATIVE TUBERCULOSIS IN SOCIALLY SAFE PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Mordyk

    2014-01-01

    Full Text Available The assessment of immunological indicators in 76 first time diagnosed infiltrative tuberculosis of lungs in socially safe patients prior to treatment and in 2 months of chemotherapy was carried out. It is revealed that immunological disorders are connected with efficiency of tuberculosis treatment . It can be criterion of quality of provided chemotherapy. The activation of cell immunity, stimulation of phagocytosis activity of neutrophils would contribute for effective treatment of tuberculosis.

  20. Remote handling at LAMPF

    International Nuclear Information System (INIS)

    Grisham, D.L.; Lambert, J.E.

    1983-01-01

    Experimental area A at the Clinton P. Anderson Meson Physics Facility (LAMPF) encompasses a large area. Presently there are four experimental target cells along the main proton beam line that have become highly radioactive, thus dictating that all maintenance be performed remotely. The Monitor remote handling system was developed to perform in situ maintenance at any location within area A. Due to the complexity of experimental systems and confined space, conventional remote handling methods based upon hot cell and/or hot bay concepts are not workable. Contrary to conventional remote handling which require special tooling for each specifically planned operation, the Monitor concept is aimed at providing a totally flexible system capable of remotely performing general mechanical and electrical maintenance operations using standard tools. The Monitor system is described

  1. Bucket-handle meniscal tears of the knee: sensitivity and specificity of MRI signs

    International Nuclear Information System (INIS)

    Dorsay, Theodore A.; Helms, Clyde A.

    2003-01-01

    To determine the sensitivity and specificity of reported MRI signs in the evaluation of bucket-handle tears of the knee.Design and patients A retrospective analysis of 71 knee MR examinations that were read as displaying evidence of a bucket-handle or ''bucket-handle type'' tear was performed. We evaluated for the presence or absence of the absent bow tie sign, the coronal truncation sign, the double posterior cruciate ligament (PCL) sign, the anterior flipped fragment sign, and a fragment displaced into the intercondylar notch. Sensitivity and specificity were calculated relative to the gold standard of arthroscopy. Forty-three of 71 cases were surgically proven as bucket-handle tears. The absent bow tie sign demonstrated a sensitivity of 88.4%. The presence of at least one of the displaced fragment signs had a sensitivity of 90.7%. A finding of both the absent bow tie sign and one of the displaced fragment signs demonstrated a specificity of 85.7%. The double PCL sign demonstrated a specificity of 100%. The anterior flipped meniscus sign had a specificity of 89.7%. Bucket-handle tears of the menisci, reported in about 10% of most large series, have been described by several signs with MRI. This report gives the sensitivity and specificity of MRI for bucket-handle tears using each of these signs independently and in combination. MRI is shown to be very accurate for diagnosing bucket-handle tears when two or more of these signs coexist. (orig.)

  2. A study of work stress, patient handling activities and the risk of low back pain among nurses in Hong Kong.

    Science.gov (United States)

    Yip, Y

    2001-12-01

    Low back pain (LBP) remains a common and costly problem among the nursing profession. Several studies have indicated that LBP is attributed to mentally straining or demanding work, fatigue or exhaustion or general work satisfaction. This study aims to measure the magnitude of LBP among Hong Kong nurses and its association with the work-related psychological strain and patients handling activities. RESEARCH METHODS AND MEASURES: A cross-sectional study of Hong Kong hospital nurses was conducted. Three hundred and seventy-seven nurses were recruited from six district hospitals. They were registered nurses or enrolled nurses working full-time for at least 1 month in the current ward. One hundred and seventy-eight (47.2%) study subjects were randomly selected from two district hospitals and 199 (52.8%) study nurses made up the convenience sample. Possible bias from psychological distress, socio-demographics and lifestyle factors was controlled for. Data were collected by face-to-face interviews. The data included work factors (both psychological stress and patient handling activities related to work), demographics, psychological distress and lifestyle factors and the occurrence of LBP. Of the 377 nurses interviewed, 153 (40.6%) reported having LBP within the last 12 months. With symptoms of LBP as the outcome, risks were increased where nurses self-reported that they only occasionally or never enjoyed their work [adjusted odds ratio (OR) 2.07], where frequent manual repositioning of patients on the bed was required (adjusted OR 1.84) and where they were required to assist patients while walking (adjusted OR 2.11) after adjustment for other potential confounders. The results indicate that an association exists between work stress, manual lifting and LBP prevalence. The main route to prevention of LBP among nurses is likely to lie in improved ergonomics and psychological health in their work place. Good posture and correct transferring techniques in ward situations

  3. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  4. Is magnetic resonance imaging safe for patients with retained metal fragments from combat and terrorist attacks?

    International Nuclear Information System (INIS)

    Eshed, Iris; Kushnir, Tamar; Shabshin, Noga; Konen, Eli

    2010-01-01

    Background: Increasing numbers of military confrontations and terrorist attacks have led to increasing reports of retained metal fragments among patients referred for magnetic resonance imaging (MRI). The potential hazard of retained metal fragments for patients undergoing MRI has been studied among patients with retained metal fragments from domestic violence but not from combat and terrorist attacks. Purpose: To retrospectively evaluate the safety of MRI in patients with subcutaneous warfare-metal fragments. Material and Methods: 10,322 consecutive metal screening forms of patients scheduled for 1.5 Tesla (T) MR examination were retrospectively reviewed. All patients reported to have retained metal fragments were contacted by telephone and asked to describe the event in which they were exposed to the fragments and for any adverse sequelae or sensations during and after MRI. Their radiographs were evaluated for the number and size of the fragments. The data were analyzed for correlations between these factors. Results: Seven of the 24 patients who reported retained metal fragments were excluded, since there was no validating evidence of their presence. Fragments in the remaining 17 patients (18 MRI examinations) were inflicted by military or terrorist attacks that occurred 2-39 years prior to the MRI. The fragment size ranged between 1 and 10 mm. One patient reported a superficial migration of a 10-mm fragment after MRI. No other adverse reactions were reported. Conclusion: Conducting 1.5T MRI examinations is safe in patients with retained metal fragments from combat and terrorist attacks not in the vicinity of vital organs. However, caution is advised.

  5. Is magnetic resonance imaging safe for patients with retained metal fragments from combat and terrorist attacks?

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, Iris; Kushnir, Tamar; Shabshin, Noga; Konen, Eli (Dept. of Diagnostic Imaging, Sheba Medical center, Tel Hashomer, Sackler School of Medicine, Tel Aviv Univ., Tel Aviv (Israel)), e-mail: iris.eshed@sheba.health.gov.il

    2010-03-15

    Background: Increasing numbers of military confrontations and terrorist attacks have led to increasing reports of retained metal fragments among patients referred for magnetic resonance imaging (MRI). The potential hazard of retained metal fragments for patients undergoing MRI has been studied among patients with retained metal fragments from domestic violence but not from combat and terrorist attacks. Purpose: To retrospectively evaluate the safety of MRI in patients with subcutaneous warfare-metal fragments. Material and Methods: 10,322 consecutive metal screening forms of patients scheduled for 1.5 Tesla (T) MR examination were retrospectively reviewed. All patients reported to have retained metal fragments were contacted by telephone and asked to describe the event in which they were exposed to the fragments and for any adverse sequelae or sensations during and after MRI. Their radiographs were evaluated for the number and size of the fragments. The data were analyzed for correlations between these factors. Results: Seven of the 24 patients who reported retained metal fragments were excluded, since there was no validating evidence of their presence. Fragments in the remaining 17 patients (18 MRI examinations) were inflicted by military or terrorist attacks that occurred 2-39 years prior to the MRI. The fragment size ranged between 1 and 10 mm. One patient reported a superficial migration of a 10-mm fragment after MRI. No other adverse reactions were reported. Conclusion: Conducting 1.5T MRI examinations is safe in patients with retained metal fragments from combat and terrorist attacks not in the vicinity of vital organs. However, caution is advised.

  6. Development of advanced loop-type fast reactor in Japan (4): An advanced design of the fuel handling system for the enhanced economic competitiveness

    International Nuclear Information System (INIS)

    Usui, S.; Mihara, T.; Obata, H.; Kotake, S.

    2008-01-01

    Refueling operation of sodium fast reactor (SFR) is one of major technical issue due to the chemical activities and opaqueness of sodium coolant properties in comparison with that of LWR. In the Japan Atomic Energy Agency (JAEA) sodium cooled Fast Reactor (JSFR) design study, the further reliable and rational fuel handling system (FHS) has been developing based on the experience of safe and reliable fuel handling operation in the existent SFR plants. Some of advanced concepts for the FHS have being studied in order to increase economic competitiveness further by attempting reduction of the amount of the material and the refueling time, and are scheduled to execute elemental tests and/or mock-up tests to confirm their feasibilities. (authors)

  7. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  8. Spinal Anaesthesia is Safe in a Patient with Wolff-Parkinson-White Syndrome Undergoing Evacuation of Molar Pregnancy.

    Science.gov (United States)

    Deviseti, Pravalika; Pujari, Vinayak S

    2016-02-01

    Wolff-Parkinson-White (WPW) syndrome is an uncommon cardiac condition where there is an abnormal band of atrial tissue connecting atria and ventricles which can electrically bypass atrioventricular node. The anaesthetic management in these patients is challenging as life threatening complications can occur perioperatively like paroxysmal supraventricular tachycardia and atrial fibrillation. Also, regional anaesthetic technique like subarachnoid block is a safe and cost effective alternative to general anaesthesia as it avoids polypharmacy. We report the successful anaesthetic management of Wolff Parkinson White syndrome in a primi with hydatiform mole posted for suction and evacuation.

  9. Sophisticated fuel handling system evolved

    International Nuclear Information System (INIS)

    Ross, D.A.

    1988-01-01

    The control systems at Sellafield fuel handling plant are described. The requirements called for built-in diagnostic features as well as the ability to handle a large sequencing application. Speed was also important; responses better than 50ms were required. The control systems are used to automate operations within each of the three main process caves - two Magnox fuel decanners and an advanced gas-cooled reactor fuel dismantler. The fuel route within the fuel handling plant is illustrated and described. ASPIC (Automated Sequence Package for Industrial Control) which was developed as a controller for the plant processes is described. (U.K.)

  10. Options and processes for spent catalyst handling and utilization.

    Science.gov (United States)

    Marafi, M; Stanislaus, A

    2003-07-18

    The quantity of spent hydroprocessing catalysts discarded as solid wastes in the petroleum refining industries has increased remarkably in recent years due to a rapid growth in the hydroprocessing capacity to meet the rising demand for low-sulfur fuels. Due to their toxic nature, spent hydroprocessing catalysts have been branded as hazardous wastes, and the refiners are experiencing pressure from environmental authorities to handle them safely. Several alternative methods such as reclamation of metals, rejuvenation and reuse, disposal in landfills and preparation of useful materials using spent catalysts as raw materials are available to deal with the spent catalyst problem. The technical feasibility as well as the environmental and economic aspects of these options are reviewed. In addition, details of two bench-scale processes, one for rejuvenation of spent hydroprocessing catalysts, and the other for producing non-leachable synthetic aggregate materials that were developed in this laboratory, are presented in this paper.

  11. 76 FR 81904 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Science.gov (United States)

    2011-12-29

    ... Medicaid Patient and Program Protection Act of 1987, Public Law 100-93 Sec. 14, the Act, Sec. 1128B(b), 42...-called ``safe harbor'' provisions, specifying various payment and business practices that, although... basis for administrative sanctions. OIG safe harbor provisions have been developed ``to limit the reach...

  12. The natural angle between the hand and handle and the effect of handle orientation on wrist radial/ulnar deviation during maximal push exertions.

    Science.gov (United States)

    Young, Justin G; Lin, Jia-Hua; Chang, Chien-Chi; McGorry, Raymond W

    2013-01-01

    The purpose of this experiment was to quantify the natural angle between the hand and a handle, and to investigate three design factors: handle rotation, handle tilt and between-handle width on the natural angle as well as resultant wrist radial/ulnar deviation ('RUD') for pushing tasks. Photographs taken of the right upper limb of 31 participants (14 women and 17 men) performing maximal seated push exertions on different handles were analysed. Natural hand/handle angle and RUD were assessed. It was found that all of the three design factors significantly affected natural handle angle and wrist RUD, but participant gender did not. The natural angle between the hand and the cylindrical handle was 65 ± 7°. Wrist deviation was reduced for handles that were rotated 0° (horizontal) and at the narrow width (31 cm). Handles that were tilted forward 15° reduced radial deviation consistently (12-13°) across handle conditions. Manual materials handling (MMH) tasks involving pushing have been related to increased risk of musculoskeletal injury. This study shows that handle orientation influences hand and wrist posture during pushing, and suggests that the design of push handles on carts and other MMH aids can be improved by adjusting their orientation to fit the natural interface between the hand and handle.

  13. Year-end technical stop: train to work safely

    CERN Multimedia

    Rosaria Marraffino

    2016-01-01

    As mentioned in the previous issue of the Bulletin (see here), the accelerators are currently undergoing maintenance as part of the year-end technical stop (YETS). Hundreds of people are working simultaneously on different machines, and many of them need to be trained in order to work safely underground. From a Safety Training point of view, this has resulted in a significant increase in training requests, most of them at the last minute, which are now being handled – but not without difficulties.     In the LHC mock-up, a helium leak is simulated. In this stressful situation, the trainees learn how to put their mask on in less than 40 seconds.   "The most requested course is the Self-Rescue Mask classroom training,” explains Christoph Balle, Safety Training Section Leader. “In this course, people are trained to face the oxygen deficiency hazards that may occur in CERN's underground areas, learning...

  14. 9 CFR 3.118 - Handling.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Handling. 3.118 Section 3.118 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment, and Transportation of Marine...

  15. Safety measuring for sodium handling

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Jeong, K C; Kim, T J; Kim, B H; Choi, J H

    2001-09-01

    This is the report for the safety measures of sodium handling. These contents are prerequisites for the development of sodium technology and thus the workers participate in sodium handling and experiments have to know them perfectly. As an appendix, the relating parts of the laws are presented.

  16. A Perspective on Remote Handling Operations and Human Machine Interface for Remote Handling in Fusion

    International Nuclear Information System (INIS)

    Haist, B.; Hamilton, D.; Sanders, St.

    2006-01-01

    A large-scale fusion device presents many challenges to the remote handling operations team. This paper is based on unique operational experience at JET and gives a perspective on remote handling task development, logistics and resource management, as well as command, control and human-machine interface systems. Remote operations require an accurate perception of a dynamic environment, ideally providing the operators with the same unrestricted knowledge of the task scene as would be available if they were actually at the remote work location. Traditional camera based systems suffer from a limited number of viewpoints and also degrade quickly when exposed to high radiation. Virtual Reality and Augmented Reality software offer great assistance. The remote handling system required to maintain a tokamak requires a large number of different and complex pieces of equipment coordinating to perform a large array of tasks. The demands on the operator's skill in performing the tasks can escalate to a point where the efficiency and safety of operations are compromised. An operations guidance system designed to facilitate the planning, development, validation and execution of remote handling procedures is essential. Automatic planning of motion trajectories of remote handling equipment and the remote transfer of heavy loads will be routine and need to be reliable. This paper discusses the solutions developed at JET in these areas and also the trends in management and presentation of operational data as well as command, control and HMI technology development offering the potential to greatly assist remote handling in future fusion machines. (author)

  17. STRRAP system-A software for hazardous materials risk assessment and safe distances calculation

    International Nuclear Information System (INIS)

    Godoy, S.M.; Santa Cruz, A.S.M.; Scenna, N.J.

    2007-01-01

    This work presents a powerful computational tool (Stochastic Toxic Release Risk Assessment Package, STRRAP) useful in risk assessment and emergency planning (safe distance calculation), which allows to handle the stochastic uncertainty of atmospheric parameters, critical for risk calculation when diffusion of hazardous gases or particulate matter occur as a consequence of an emission or accidental release. In fact, the random behaviour of wind intensity, wind direction, atmospheric stability and temperature, given a time horizon, (a season or a complete year), is taken into account considering also the day or night condition. STRRAP can be used for releases or emissions from static sources (for example a stack or a fixed tank in a facility) or from transportation accidents (road, rail, maritime and pipeline transport) involving different scenarios. After a stochastic simulation based on well-known diffusion models (dense and light gases, particulate matter) is carried out, the downwind pollutant concentrations are obtained, in order to compute safe distances and/or individual and societal risks. Some study cases are analyzed to show STRRAP capabilities

  18. PREVALENCE OF LOW BACK PAIN AND LEVEL OF KNOWLEDE ABOUT PATIENT HANDLING AND SHIFTING TECHNIQUES AMONG NURSES OF A PUBLIC SECTOR HOSPITAL IN KARACHI A SURVEY

    Directory of Open Access Journals (Sweden)

    Ferkhanda Imdad

    2016-04-01

    Full Text Available Background: Low back pain has been found to be the most prevailing musculoskeletal condition as well as a common cause of absence from workplace. Studies report that low back pain is common and accounts for a large number of reported disabilities among nurses. In fact nursing have one of the highest levels of back injury in all occupation groups. The aim of this study is to determine the prevalence of low back pain among nurses in a public sector teaching hospital of Karachi. This study has mainly focused on confounding factors leading to low back pain and level of education among nurses regarding patients handling or shifting techniques. Methods: A self-administered questionnaires comprises of three sections, were used to collect data. The first section requested for socio-demographic information, followed by medical history of back pain during last month and during last year.The second section assessed the medical history of LBP in two categories i.e. during last month and during last year.The third and last section inquired about participants’ level of education about ergonomics with simply in yes or no pattern.The questionnaires were given to 100 nurses. All questionnaires were completed in the presence of theresearcher. Out of 100 questionnaires distributed and recorded, only 47 participants returned the questionnaire. Results: Statistical Package for the Social Sciences (SPSS version 19.0 was used for statistical analysis. Relationship between the prevalence of low back pain and training in patient moving techniques, manual material handling techniques is significant (p=0.017,p= 0.068. There is a weak relationship with the knowledge of ergonomics, biomechanics and back pain preventive measures (p=0.719,p=0.457,p=0.704. Conclusion: More than two third of the participated nurses were well trained in transfer techniques, manual material training and preventive measures of back pain. But they lack the biomechanical knowledge. The prevalence

  19. Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa) delivered via a disposable autoinjector device

    Science.gov (United States)

    Varunok, Peter; Lawitz, Eric; Beavers, Kimberly L; Matusow, Gary; Leong, Ruby; Lambert, Nathalie; Bernaards, Coen; Solsky, Jonathan; Brennan, Barbara J; Wat, Cynthia; Bertasso, Anne

    2011-01-01

    Background Peginterferon alfa-2a (40 kDa) is currently administered using a prefilled syringe. The peginterferon alfa-2a disposable autoinjector is a new safety-engineered device designed to facilitate injection and reduce the risk of needlestick injuries. The analysis of two open-label Phase I trials evaluated the pharmacokinetics, successful administration, and tolerability of peginterferon alfa-2a when using the autoinjector. The studies were performed to support the filing and registration of the autoinjector device. Methods In trial 1, 50 healthy adult subjects received one 180 μg dose of peginterferon alfa-2a via the autoinjector. Serial blood samples were collected predose, up to 336 hours following drug administration, and at follow-up (28 ± 3 days post-dosing) for noncompartmental pharmacokinetic analysis. Trial 2 randomized 60 adult patients with chronic hepatitis C to 180 μg peginterferon alfa-2a once weekly by the autoinjector or prefilled syringe for 3 weeks followed by the alternative device (prefilled syringe or autoinjector, respectively) for 3 weeks. Patients also received ribavirin. Administration by the devices was evaluated under direct observation by a study staff member and by patient subjective assessment. Results In trial 1, following a single dose of peginterferon alfa-2a, the maximum plasma concentration was 16.1 ± 5.3 ng/mL (mean ± standard deviation), and area under the concentration time curve (0–168 hours) was 1996 ± 613 ng · hour/mL, similar to that reported using a vial/syringe or prefilled syringe. In trial 2, few patients showed handling difficulties with either device. Generally, patients were observed to be more satisfied and confident, followed instructions better, and successfully initiated injection with the autoinjector versus the prefilled syringe. Patients reported the autoinjector to be more convenient and easier to use. No pain or discomfort was experienced using the autoinjector. The autoinjector safety profile

  20. High output stomas: ensuring safe discharge from hospital to home.

    Science.gov (United States)

    Smith, Lisa

    High-output stomas are a challenge for the patient and all health professionals involved. This article discusses safe discharge home for this patient group, encouraging collaborative working practices between acute care trust and the community services. The authors also discuss the management of a high-output stoma and preparation and education of the patient before discharge home.

  1. Liquefied natural gas (LNG) : production, storage and handling. 7. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Kalra, S; Jaron, K; Adragna, M; Coyle, S; Foley, C; Hawryn, S; Martin, A; McConnell, J [eds.

    2003-07-01

    This Canadian Standard on the production, storage and handling of liquefied natural gas (LNG) was prepared by the Technical Committee on Liquefied Natural Gas under the jurisdiction of the Steering Committee on Oil and Gas Industry Systems and Materials. It establishes the necessary requirements for the design, installation and safe operation of LNG facilities. The Standard applies to the design, location, construction, operation and maintenance of facilities at any location of the liquefaction of natural gas and for the storage, vaporization, transfer, handling and truck transport of LNG. The training of personnel involved is also included as well as containers for LNG storage, including insulated vacuum systems. It includes non-mandatory guidelines for small LNG facilities but does not apply to the transportation of refrigerants, LNG by rail, marine vessel or pipeline. This latest edition contains changes in working of seismic design requirements and minor editorial changes to several clauses to bring the Standard closer to the US National Fire Protection Association's Committee on Liquefied Natural Gas Standard while maintaining Canadian regulatory requirements. The document is divided into 12 sections including: general requirements; plant site provisions; process equipment; stationary LNG storage containers; vaporization facilities; piping system and components; instrumentation and electrical services; transfer of LNG and refrigerants; fire protection, safety and security; and, operating, maintenance and personnel training. This Standard, like all Canadian Standards, was subject to periodic review and was most recently reaffirmed in 2003. 6 tabs., 6 figs., 3 apps.

  2. Medical handling of accidentally exposed individuals

    International Nuclear Information System (INIS)

    1988-01-01

    In 1978 the International Atomic Energy Agency issued a publication in the IAEA Safety Series entitled Manual on Early Medical Treatment of Possible Radiation Injury (Safety Series No. 47). The contents were directed to first aid and early medical treatment of workers who might be concerned in an accident involving exposure to radiation, whether external or internal. The present manual is the first of a set of three safety series publications dealing with assessment and treatment of overexposures which will constitute an articulated system of documents covering all aspects of diagnosis, prognosis and treatment of overexposures. This document establishes a set of general criteria and recommendations to aid specialists involved in the medical handling of overexposed persons. It deals with the medical management of individual patients or small groups of patients under close medical supervision. 14 refs, 7 figs, 7 tabs

  3. Fuel-handling machine tests at the Institute for Nuclear Research - Pitesti. Computer and software research and engineering

    International Nuclear Information System (INIS)

    Doca, Cezar; Predescu, Darie; Maiorescu, Oliviu; Dobrescu, Sorin

    2003-01-01

    This poster introduces the fuel-handling machine SCC-MID. This work is part of a very ambitious project that was accomplished with remarkable investment efforts. Material and human resources was spent to build a test stand for fuel handling machines (CANDU system), closely linked to NPP Cernavoda. A challenging goal was also to develop a computer system (hw/sw) designed and engineered to control the test and calibration process of this fuel-handling machine. The design takes care both of the functionality required to correctly control the F/H machine and of the additional functionality required to assist the testing process. How to test the system itself to validate the implemented solutions, how to safely and consistently maintain the data involved, how to manage such a system, how to gradually integrate the system in the whole stand saving time and work already done and solutions already validated were questions we had to find out right solutions. We choose modular solutions both for hardware and software, based on late technologies which in addition permit to achieve the versatility we needed, namely: VME based hw systems running OS9/68k (Unix like real-time multi-user multitasking OS), ISaGRAF (process control application oriented development and run-time software), Hawk (cross-compiler and IDE software for C/C++ software development intended to run on other Motorola based hw), Suretrack (project management software). The system topology implements open system network concepts that permit communication between different sw/hw platforms (OS9/Motorola and ix86/ms-windows based systems) We spent major resources to model the technological processes and test tools like: - real time simulation of the machine behavior while responding to the human commands or to the state changes of other machine parts as a result of other commands or as mechanical interlinks or technological interlocks and presentation of results revealing time related movements; - database

  4. Handling and disposal of radioactive scrap

    International Nuclear Information System (INIS)

    Witte, K.

    1975-01-01

    The 9th special course for journalists was in this year on the highly topical subject 'handling and disposal of radioactive scrap'. It was held on the 26th and 27th May 1975 at the Nuclear Research Centre at Karlsruhe. These courses have been held for several years by the Nuclear Research Association (GfK) in the School for Nuclear Engineering and are intended mainly to contribute to journalists of the daily papers, radio and television who are 'not previously technically trained' an introduction into the difficult subject matter of nuclear engineering with its ancillary areas. In view of the many discussions carried on in public the course is further intended to achieve that the problems discussed are treated by means of publicity which is free from emotion. In the journalists' course this year specially selected experts gave technical information prepared for general information as to how radioactive waste can be safely worked up and then finally stored without adverse effects on the environment. Since the interesting collection of questions was put forward in a compressed form and at the same time clearly presented, the author reports on the different separate subjects on which lectures were given. (orig.) [de

  5. Family caregivers' experience of activities of daily living handling in older adult with stroke: a qualitative research in the Iranian context.

    Science.gov (United States)

    Hesamzadeh, Ali; Dalvandi, Asghar; Bagher Maddah, Sadat; Fallahi Khoshknab, Masoud; Ahmadi, Fazlollah; Mosavi Arfa, Nazila

    2017-09-01

    Patients with stroke require additional support from family to live independently in the area of activities of daily living. Family members are usually the main caregivers of stroke patients. Comprehensive explanation of ADL handling from family caregivers' view is lacking. This study explores and describes family caregivers' experiences about the strategies to handle activities of daily living (ADL) dependency of elderly patient with stroke in the Iranian context. A qualitative content analysis approach was conducted to analyse data. Nineteen family caregivers participated in the study from multiple physiotherapy clinics of physiotherapy in Sari (Iran) between September 2013 and May 2014. Data were generated through in-depth interviews, and content analysis method was used to analyse the data and determine themes. The findings show that family caregivers manage the ADL dependency of their elderly stroke patients through seven strategies including encouraging physical movements, providing personal hygiene, nutritional consideration, facilitating religious activities, filling leisure time, and facilitating transfer and assisting in financial issues. Family has an important role in handling of elderly stroke patients' ADL dependency. Health practitioners can take benefit from the findings to help the stroke families play more active role in the handling ADL dependency of their patients after stroke. © 2016 Nordic College of Caring Science.

  6. Validity and reliability of a self-administered foot evaluation questionnaire (SAFE-Q).

    Science.gov (United States)

    Niki, Hisateru; Tatsunami, Shinobu; Haraguchi, Naoki; Aoki, Takafumi; Okuda, Ryuzo; Suda, Yasunori; Takao, Masato; Tanaka, Yasuhito

    2013-03-01

    The Japanese Society for Surgery of the Foot (JSSF) is developing a QOL questionnaire instrument for use in pathological conditions related to the foot and ankle. The main body of the outcome instrument (the Self-Administered Foot Evaluation Questionnaire, SAFE-Q version 2) consists of 34 questionnaire items, which provide five subscale scores (1: Pain and Pain-Related; 2: Physical Functioning and Daily Living; 3: Social Functioning; 4: Shoe-Related; and 5: General Health and Well-Being). In addition, the instrument has nine optional questionnaire items that provide a Sports Activity subscale score. The purpose of this study was to evaluate the test-retest reliability of the SAFE-Q. Version 2 of the SAFE-Q was administered to 876 patients and 491 non-patients, and the test-retest reliability was evaluated for 131 patients. In addition, the SF-36 questionnaire and the JSSF Scale scoring form were administered to all of the participants. Subscale scores were scaled such that the final sum of scores ranged between zero (least healthy) to 100 (healthiest). The intraclass correlation coefficients were larger than 0.7 for all of the scores. The means of the five subscale scores were between 60 and 75. The five subscales easily separated patients from non-patients. The coefficients for the correlations of the subscale scores with the scores on the JSSF Scale and the SF-36 subscales were all highly statistically significantly greater than zero (p valid and reliable. In the future, it will be beneficial to test the responsiveness of the SAFE-Q.

  7. Remote-handled transuranic system assessment appendices. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives.

  8. Remote-handled transuranic system assessment appendices. Volume 2

    International Nuclear Information System (INIS)

    1995-11-01

    Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives

  9. DroidSafe

    Science.gov (United States)

    2016-12-01

    Massachusetts Avenue, Build E19-750 Cambridge , MA 02139-4307 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS...Activity objects illustrating the challenges of points-to and information flow analysis...measure how many malicious flows Droid- Safe was able to detect). As these results illustrate , DroidSafe implements an analysis of unprece- dented

  10. Vacuum-Assisted Abdominal Closure Is Safe and Effective

    DEFF Research Database (Denmark)

    Jensen, R O; Buchbjerg, T; Simonsen, R M

    2017-01-01

    less likely to develop large hernias and had better self-evaluated physical health score (p mental health was found. CONCLUSION: The abdominal VAC treatment in patients with abdominal catastrophes is safe and with a relative low complication rate. Whether it might be superior...

  11. Women of low socioeconomic status living with diabetes: Becoming adept at handling a disease

    Directory of Open Access Journals (Sweden)

    Wimonrut Boonsatean

    2015-12-01

    Full Text Available Objective: The objective of this study was to explore how Thai women of low socioeconomic status handle their type 2 diabetes. Methods: A qualitative interpretative method was used to study 19 women with type 2 diabetes in a suburban community in Thailand. Data were collected via semi-structured interviews and were analysed using inductive and constructive processes. Results: Participants’ lives underwent many changes between their initial diagnoses and later stages when they became adept at handling diabetes. Two themes emerged, which involved (1 the transition to handling diabetes and (2 the influences of the social environment. The first theme encompassed confronting the disease, reaching a turning point in the process of adaptation and developing expertise in handling diabetes. The second theme involved threats of loss of status and empowerment by families. These findings showed that becoming adept at handling diabetes required significant changes in women’s behaviours and required taking advantage of influences from the social environment. Conclusion: The process of developing expertise in handling diabetes was influenced by both inner and outer factors that required adjustment to learn to live with diabetes. Furthermore, the reductions found in women’s social statuses when they become patients in the healthcare system might pose a barrier to women of low socioeconomic status becoming adept at handling diabetes. However, the experiences of empowerment received from the women’s families acted as a powerful strategy to strengthen their handling of the disease. To develop accessible and sensitive health care for this population, it is important to pay attention to these findings.

  12. Safe havens in Europe

    DEFF Research Database (Denmark)

    Paldam, Martin

    2013-01-01

    Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11 countries are richer than their large neighbors. It is shown that causality is from small to safe haven to wealth, and that theoretically...... equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity...... of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds....

  13. Health physics monitoring during cobalt slug rod handling at research reactor Dhruva: an experience

    International Nuclear Information System (INIS)

    Verma, Gopal P.; Bhatnagar, Amit; Krishnamohanan, T.; Kalyanasundaram, N.; Gupta, P.C.; Pushparaja; Ghosh, Runner

    2006-01-01

    Cobalt-60 is used in many industrial and medical applications, such as leveling devices, thickness gauge, sterilization of foodstuff to increase their shelf life, sterilization of medicines and in radiotherapy. The Cobalt slug rod containing cobalt pencils were irradiated for nearly two and half years in the Dhruva reactor core to obtain the 60 Co isotope. It had seen a total irradiation of 29053 MWD and the estimated total activity was 93.321 KCi. Campaign for the removal of irradiated rod from reactor core and retrieval of 60 Co pencils were carried out successfully in Dhruva Reactor complex. In view of such a high activity handled, the job was carried out after exhaustive prior planning and according to approved checklists. Radiation Hazards Control Unit, Dhruva provided Radiation Safety surveillance during the entire handling operation consisting of retrieval of the cobalt pencils and disposal of the aluminum slugs used to house the cobalt pencils in the Cobalt slug rod assembly. The whole operation was carried out in such a safe manner that the total man-rem consumption was insignificant. The operational radiation protection methods followed and the experience gained during the campaign are discussed in this paper. (author)

  14. Traveling Safely with Medicines

    Science.gov (United States)

    ... Medications Safely My Medicine List How to Administer Traveling Safely with Medicines Planes, trains, cars – even boats ... your trip, ask your pharmacist about how to travel safely with your medicines. Make sure that you ...

  15. DDOS ATTACK DETECTION SIMULATION AND HANDLING MECHANISM

    Directory of Open Access Journals (Sweden)

    Ahmad Sanmorino

    2013-11-01

    Full Text Available In this study we discuss how to handle DDoS attack that coming from the attacker by using detection method and handling mechanism. Detection perform by comparing number of packets and number of flow. Whereas handling mechanism perform by limiting or drop the packets that detected as a DDoS attack. The study begins with simulation on real network, which aims to get the real traffic data. Then, dump traffic data obtained from the simulation used for detection method on our prototype system called DASHM (DDoS Attack Simulation and Handling Mechanism. From the result of experiment that has been conducted, the proposed method successfully detect DDoS attack and handle the incoming packet sent by attacker.

  16. Catheter-based intervention for symptomatic patient with severe mitral regurgitation and very poor left ventricular systolic function - Safe but no room for complacency.

    Science.gov (United States)

    Loh, Poay Huan; Bourantas, Christos V; Chan, Pak Hei; Ihlemann, Nikolaj; Gustafsson, Fin; Clark, Andrew L; Price, Susanna; Mario, Carlo Di; Moat, Neil; Alamgir, Farqad; Estevez-Loureiro, Rodrigo; Søndergaard, Lars; Franzen, Olaf

    2015-11-26

    Many patients with left ventricular systolic dysfunction have concomitant mitral regurgitation (MR). Their symptoms and prognosis worsen with increasing severity of MR. Percutaneous MitraClip(®) can be used safely to reduce the severity of MR even in patients with advanced heart failure and is associated with improved symptoms, quality of life and exercise tolerance. However, a few patients with very poor left ventricular systolic function may experience significant haemodynamic disturbance in the peri-procedural period. We present three such patients, highlighting some of the potential problems encountered and discuss their possible pathophysiological mechanisms and safety measures.

  17. Whether partial colectomy is oncologically safe for patients with transverse colon cancer: a large population-based study.

    Science.gov (United States)

    Guan, Xu; Zhao, Zhixun; Yang, Ming; Chen, Haipeng; Chen, Wei; Liu, Zheng; Jiang, Zheng; Chen, Yinggang; Wang, Guiyu; Wang, Xishan

    2017-11-03

    Due to special tumor location and technical difficulty of transverse colon cancer (TCC), partial colectomy (PC) is being widely applied in selected TCC patients, instead of extended hemicolectomy (HC). However, the oncological safety of this less aggressive surgical approach is not well studied. Here, we identified 10344 TCC patients from Surveillance, Epidemiology, and End-Results (SEER) database. The surgical treatment for those patients included PC and HC. Firstly, we compared lymph nodes evaluations between patients treated with HC and PC, including median number of nodes, the rate of nodes ≥ 12 and the rate of node positivity. Then, 5-year cancer specific survival (CSS) was obtained. Kaplan-Meier methods and Cox regression models were performed to assess the correlations between prognostic factors and long-term survival. Despite of less node examined by PC, the rate of node positivity was equal between PC and HC, suggesting node retrieval under PC was adequate to tumor stage. In addition, the 5-year CSS for patients who underwent PC were 67.5%, which was similar to patients who received HC (66.5%). The result after propensity score matching also confirmed the equivalent survival outcome between HC and PC. However, subgroup analyses showed that patients with tumor size ≥ 5 cm could not obtain survival benefit from PC. Furthermore, surgical approach was not considered as independent prognostic factor for TCC patients. Therefore, although PC is a less aggressive surgical approach, it should be a safe and feasible option for selected TCC patients.

  18. Ergonomics of disposable handles for minimally invasive surgery.

    Science.gov (United States)

    Büchel, D; Mårvik, R; Hallabrin, B; Matern, U

    2010-05-01

    The ergonomic deficiencies of currently available minimally invasive surgery (MIS) instrument handles have been addressed in many studies. In this study, a new ergonomic pistol handle concept, realized as a prototype, and two disposable ring handles were investigated according to ergonomic properties set by new European standards. In this study, 25 volunteers performed four practical tasks to evaluate the ergonomics of the handles used in standard operating procedures (e.g., measuring a suture and cutting to length, precise maneuvering and targeting, and dissection of a gallbladder). Moreover, 20 participants underwent electromyography (EMG) tests to measure the muscle strain they experienced while carrying out the basic functions (grasp, rotate, and maneuver) in the x, y, and z axes. The data measured included the number of errors, the time required for task completion, perception of pressure areas, and EMG data. The values for usability in the test were effectiveness, efficiency, and user satisfaction. Surveys relating to the subjective rating were completed after each task for each of the three handles tested. Each handle except the new prototype caused pressure areas and pain. Extreme differences in muscle strain could not be observed for any of the three handles. Experienced surgeons worked more quickly with the prototype when measuring and cutting a suture (approximately 20%) and during precise maneuvering and targeting (approximately 20%). On the other hand, they completed the dissection task faster with the handle manufactured by Ethicon. Fewer errors were made with the prototype in dissection of the gallbladder. In contrast to the handles available on the market, the prototype was always rated as positive by the volunteers in the subjective surveys. None of the handles could fulfil all of the requirements with top scores. Each handle had its advantages and disadvantages. In contrast to the ring handles, the volunteers could fulfil most of the tasks more

  19. Radiological safety aspects of handling plutonium

    International Nuclear Information System (INIS)

    Sundararajan, A.R.

    2016-01-01

    Department of Atomic Energy in its scheme of harnessing the nuclear energy for electrical power generation and strategic applications has given a huge role to utilization of plutonium. In the power production programme, fast reactors with plutonium as fuel are expected to play a major role. This would require establishing fuel reprocessing plants to handle both thermal and fast reactor fuels. So in the nuclear fuel cycle facilities variety of chemical, metallurgical, mechanical operations have to be carried out involving significant inventories of "2"3"9 Pu and associated radionuclides. Plutonium is the most radiotoxic radionuclide and therefore any facility handling it has to be designed and operated with utmost care. Two problems of major concern in the protection of persons working in plutonium handling facilities are the internal exposure to the operating personnel from uptake of plutonium and transplutonic nuclides as they are highly radiotoxic and the radiation exposure of hands and eye lens during fuel fabrication operations especially while handling recycled high burn up plutonium. In view of the fact that annual limit for intake is very small for "2"3"9Pu and its radiation emission characteristics are such that it is a huge challenge for the health physicists to detect Pu in air and in workers. This paper discusses the principles and practices followed in providing radiological surveillance to workers in plutonium handling areas. The challenges in protecting the workers from receiving exposures to hands and eye lens in handling high burn up plutonium are also discussed. The sites having Pu fuel cycle facilities should have trained medical staff to handle cases involving excessive intake of plutonium. (author)

  20. Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa delivered via a disposable autoinjector device

    Directory of Open Access Journals (Sweden)

    Varunok P

    2011-11-01

    /mL, similar to that reported using a vial/syringe or prefilled syringe. In trial 2, few patients showed handling difficulties with either device. Generally, patients were observed to be more satisfied and confident, followed instructions better, and successfully initiated injection with the autoinjector versus the prefilled syringe. Patients reported the autoinjector to be more convenient and easier to use. No pain or discomfort was experienced using the autoinjector. The autoinjector safety profile was consistent with that known for peginterferon alfa-2a/ribavirin.Conclusion: These results indicate that peginterferon alfa-2a can be successfully and safely delivered via the autoinjector and that the device is easy to handle.Keywords: peginterferon alfa-2a, disposable autoinjector, hepatitis C, pharmacokinetics, user handling

  1. Development and use of a remote waste handling system for disposal of greater confinement wastes

    International Nuclear Information System (INIS)

    Williams, R.E.

    1985-01-01

    This paper discusses the design and development of a remotely controlled waste handling system (RWHS) for use in radioactive waste disposal operations. A RWHS was developed at the US Department of Energy's (DOE) Nevada Test Site for use in the Greater Confinement Disposal Test (GCDT). The RWHS consists of a remote control console and the following remotely operated features: a crane, a grapple/manipulator module which is suspended by the crane hoist hook, and closed-circuit television cameras. The RWHS was used to safely place high-specific-activity radioactive waste in greater confinement disposal. Between December 15, 1983, and February 23, 1984, five encapsulated sources were open-air transferred from shielded shipping casks and placed 30 m down a 3-m-dia augered shaft using the RWHS. These sources contained approximately 460 kCi of 90 Sr, 21 kCi of 137 Cs, and 390 Ci of 60 Co. Each source was transferred safely and efficiently and operational personnel did not receive any recordable doses. 3 references, 5 figures

  2. Safe application of a restrictive transfusion protocol in moderate-risk patients undergoing cardiac operations.

    Science.gov (United States)

    Song, Howard K; von Heymann, Christian; Jespersen, Christian M; Karkouti, Keyvan; Korte, Wolfgang; Levy, Jerrold H; Ranucci, Marco; Saugstrup, Trine; Sellke, Frank W

    2014-05-01

    Perioperative red blood cell transfusion is associated with adverse outcomes after cardiac operations. Although restrictive transfusion protocols have been developed, their safety and efficacy are not well demonstrated, and considerable variation in transfusion practice persists. We report our experience with a restrictive transfusion protocol. We analyzed the outcomes in 409 patients undergoing cardiac operations enrolled in a trial conducted at 30 centers worldwide. Blood products were administered on the basis of a transfusion algorithm applied across all centers, with a restrictive transfusion trigger of hemoglobin less than or equal to 6 g/dL. Transfusion was acceptable but not mandatory for hemoglobin 6 to 8 g/dL. For hemoglobin 8 to 10 g/dL, transfusion was acceptable only with evidence for end-organ ischemia. The patient population was moderately complex, with 20.5% having combined procedures and 29.6% having nonelective operations. The mean EuroSCORE for the population was 4.3, which predicted a substantial incidence of morbidity and mortality. Actual outcomes were excellent, with observed mortality of 0.49% and rates of cerebrovascular accident, myocardial infarction, and acute renal failure 1.2%, 6.1%, and 0.98%, respectively. The frequency of red blood cell transfusion was 33.7%, which varied significantly by center. Most transfusions (71.9%) were administered for hemoglobin 6 to 8 g/dL; 21.4% were administered for hemoglobin 8 to 10 g/dL with evidence for end-organ ischemia; 65.0% of patients avoided allogeneic transfusion altogether. A restrictive transfusion protocol can be safely applied in the care of moderate-risk patients undergoing cardiac operations. This strategy has significant potential to reduce transfusion and resource utilization in these patients, standardize transfusion practices across institutions, and increase the safety of cardiac operations. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  3. Specialization and Flexibility in Port Cargo Handling

    Directory of Open Access Journals (Sweden)

    Hakkı KİŞİ

    2016-11-01

    Full Text Available Cargo handling appears to be the fundamental function of ports. In this context, the question of type of equipment and capacity rate need to be tackled with respect to cargo handling principles. The purpose of this study is to discuss the types of equipment to be used in ports, relating the matter to costs and capacity. The question is studied with a basic economic theoretical approach. Various conditions like port location, size, resources, cargo traffic, ships, etc. are given parameters to dictate the type and specification of the cargo handling equipment. Besides, a simple approach in the context of cost capacity relation can be useful in deciding whether to use specialized or flexible equipment. Port equipment is sometimes expected to be flexible to handle various types of cargo as many as possible and sometimes to be specialized to handle one specific type of cargo. The cases that might be suitable for those alternatives are discussed from an economic point of view in this article. Consequently, effectiveness and efficiency criteria play important roles in determining the handling equipment in ports.

  4. Improved control rod drive handling equipment for BWRs [boiling-water reactors]: Final report

    International Nuclear Information System (INIS)

    Turner, A.P.L.; Gorman, J.A.

    1987-08-01

    Improved equipment for removing and replacing control rod drives (CRDs) in BWR plants has been designed, built and tested. Control rod drives must be removed from the reactor periodically for servicing. Removal and replacement of CRDs using equipment originally supplied with the plant has long been recognized as one of the more difficult and highest radiation exposure maintenance operations that must be performed at BWR plants. The improved equipment was used for the first time at Quad Cities, Unit 2, during a Fall 1986 outage. The trial of the equipment was highly successful, and it was shown that the new equipment significantly improves CRD handling operations. The new equipment significantly simplifies the sequence of operations required to lower a CRD from its housing, upend it to a horizontal orientation, and transport it out of the reactor containment. All operations of the new equipment are performed from the undervessel equipment handling platform, thus, eliminating the requirement for a person to work on the lower level of the undervessel gallery which is often highly contaminated. Typically, one less person is required to operate the equipment than were used with the older equipment. The new equipment incorporates a number of redundant and fail safe features that improve operations and reduce the chances for accidents

  5. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  6. Radiofrequency and microwave tumor ablation in patients with implanted cardiac devices: Is it safe?

    Energy Technology Data Exchange (ETDEWEB)

    Skonieczki, Brendan D., E-mail: bskonieczki@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Wells, Catherine, E-mail: cwells1@bidmc.harvard.edu [Department of Radiology, Harvard Medical School/Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Wasser, Elliot J., E-mail: ewasser@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States)

    2011-09-15

    Purpose: To identify malfunction of implanted cardiac devices during or after thermal ablation of tumors in lung, kidney, liver or bone, using radiofrequency (RF) or microwave (MW) energy. Materials and methods: After providing written consent, 19 patients (15 men and 4 women; mean age 78 years) with pacemakers or pacemaker/defibrillators underwent 22 CT image-guided percutaneous RF or MW ablation of a variety of tumors. Before and after each procedure, cardiac devices were interrogated and reprogrammed by a trained cardiac electrophysiology fellow. Possible pacer malfunctions included abnormalities on electrocardiographic (EKG) monitoring and alterations in device settings. Our institutional review board approved this Health Insurance Portability and Accountability Act-compliant study. Informed consent for participation in this retrospective study was deemed unnecessary by our review board. Results: During 20 of 22 sessions, no abnormalities were identified in continuous, EKG tracings or pacemaker functions. However, in two sessions significant changes, occurred in pacemaker parameters: inhibition of pacing during RF application in one, session and resetting of mode by RF energy in another session. These changes did not, result in hemodynamic instability of either patient. MW ablation was not associated with, any malfunction. In all 22 sessions, pacemakers were undamaged and successfully reset to original parameters. Conclusion: RF or MW ablation of tumors in liver, kidney, bone and lung can be performed safely in patients with permanent intra-cardiac devices, but careful planning between radiology and cardiology is essential to avoid adverse outcomes.

  7. Graphite core stability during 'care and maintenance' and 'safe storage'

    International Nuclear Information System (INIS)

    Wickham, A.J.; Marsden, B.J.; Sellers, R.M.; Pilkington, N.J.

    1998-01-01

    The current decommissioning strategy for the graphite-moderated reactors operated by Magnox Electric plc, Nuclear Electric Ltd and Scottish Nuclear Ltd is to delay dismantling and to initiate a monitored period of care and maintenance followed by a period of safe storage totaling up to 135 years. This philosophy has the considerable advantage of permitting the majority of radionuclides to decay, thereby minimising personnel dose during dismantling which itself will require far less complex remote-handling equipment. It also defers the disposal of the graphite and other components so that the provision of a deep land-based repository can be achieved. A comprehensive review of all relevant data on the chemical, physical and mechanical properties of the graphite and its potential reactions, including radioactivity transport, has been undertaken in order to demonstrate that there are no potential mechanisms which might lead to degradation of the core during the storage period. It is concluded that no significant experimental work is necessary to support the safe storage philosophy although, since the ingress of rainwater over long periods of time cannot be assumed incredible, a number of anomalies in chemical leaching rates may be worthy of re-examination. No other potential chemical reactions, such as the radiolytic formation of nitric acid leading to corrosion problems, are considered significant. (author)

  8. Management of transport and handling contracts

    CERN Document Server

    Rühl, I

    2004-01-01

    This paper shall outline the content, application and management strategies for the various contracts related to transport and handling activities. In total, the two sections Logistics and Handling Maintenance are in charge of 27 (!) contracts ranging from small supply contracts to big industrial support contracts. The activities as well as the contracts can generally be divided into four main topics "Vehicle Fleet Management"; "Supply, Installation and Commissioning of Lifting and Hoisting Equipment"; "Equipment Maintenance" and "Industrial Support for Transport and Handling". Each activity and contract requires different approaches and permanent adaptation to the often changing CERN's requirements. In particular, the management and the difficulties experienced with the contracts E072 "Maintenance of lifting and hoisting equipment", F420 "Supply of seven overhead traveling cranes for LHC" and S090/S103 "Industrial support for transport and handling" will be explained in detail.

  9. Effectiveness of maximal safe resection for glioblastoma including elderly and low karnofsky performance status patients. Retrospective review at a single institute

    International Nuclear Information System (INIS)

    Uzuka, Takeo; Takahashi, Hideaki; Aoki, Hiroshi; Natsumeda, Manabu; Fujii, Yukihiko

    2012-01-01

    Elderly and low Karnofsky performance status (KPS) patients have been excluded from most prospective trials. This retrospective study investigated glioblastoma treatment outcomes, including those of elderly and low KPS patients, and analyzed the prognostic factors using the medical records of 107 consecutive patients, 59 men and 48 women aged from 21 to 85 years (median 65 years), with newly diagnosed glioblastoma treated at our institute. There were 71 high-risk patients with age >70 years and/or KPS 6 -methylguanine-deoxyribonucleic acid methyltransferase-negative (p=0.027), and more than subtotal removal (p=0.003) were significant prognostic factors. The median postoperative KPS score tended to be better than the preoperative score, even in the high-risk group. We recommend maximal safe resection for glioblastoma patients, even those with advanced age and/or with low KPS scores. (author)

  10. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  11. Safe and unsafe duration of fasting for children with MCAD deficiency

    NARCIS (Netherlands)

    Derks, Terry G J; van Spronsen, Francjan J; Rake, Jan Peter; van der Hilst, Christian S; Span, Mark M; Smit, G Peter A

    OBJECTIVE: To study the safe and unsafe duration of fasting in children with medium chain acyl-Coenzyme A dehydrogenase (MCAD) deficiency, the literature and the database on Dutch MCAD-deficient patients were searched for data on fasting studies in patients with MCAD deficiency. MATERIALS AND

  12. Welding method by remote handling

    International Nuclear Information System (INIS)

    Hashinokuchi, Minoru.

    1994-01-01

    Water is charged into a pit (or a water reservoir) and an article to be welded is placed on a support in the pit by remote handling. A steel plate is disposed so as to cover the article to be welded by remote handling. The welding device is positioned to the portion to be welded and fixed in a state where the article to be welded is shielded from radiation by water and the steel plate. Water in the pit is drained till the portion to be welded is exposed to the atmosphere. Then, welding is conducted. After completion of the welding, water is charged again to the pit and the welding device and fixing jigs are decomposed in a state where the article to be welded is shielded again from radiation by water and the steel plate. Subsequently, the steel plate is removed by remote handling. Then, the article to be welded is returned from the pit to a temporary placing pool by remote handling. This can reduce operator's exposure. Further, since the amount of the shielding materials can be minimized, the amount of radioactive wastes can be decreased. (I.N.)

  13. Is hydroxyethyl starch 130/0.4 safe?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2012-01-01

    ABSTRACT: It is heavily debated whether or not treatment with hydroxyethyl starch 130/0.4 contributes to the development of acute kidney failure in patients with severe sepsis. In the previous issue of Critical Care, Muller and colleagues report no association between initial resuscitation...... with hydroxyethyl starch 130/0.4 and renal impairment in a cohort of septic patients. Can we then consider hydroxyethyl starch 130/0.4 a safe intervention? The answer is no - observational data should be interpreted with caution and should mainly be used to identify risks, while safety must be assessed...

  14. {sup 177}Lu-octreotate, alone or with radiosensitising chemotherapy, is safe in neuroendocrine tumour patients previously treated with high-activity {sup 111}In-octreotide

    Energy Technology Data Exchange (ETDEWEB)

    Hubble, Daniel; Kong, Grace; Michael, Michael; Johnson, Val; Ramdave, Shakher; Hicks, Rodney John [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2010-10-15

    The aim of this retrospective study was to determine whether patients with previous peptide receptor radionuclide therapy using high-activity {sup 111}In-pentetreotide can be safely treated with {sup 177}Lu-octreotate and whether addition of radiosensitising chemotherapy increases the toxicity of this agent. Records of 27 patients (aged 17-75) who received 69 (median 3 per patient) {sup 177}Lu-octreotate administrations, including 29 in conjunction with radiosensitising infusional 5-fluorouracil (5-FU) (n = 27), or capecitabine (n = 2), between October 2005 and July 2007 subsequent to 1-8 prior cycles of {sup 111}In-pentetreotide therapy were analysed. Toxicity was assessed during and at 8-12 weeks post-treatment, with further long-term assessments including survival status reviewed till death or study close-out date of 1 November 2009. Reduction in blood counts was most marked following the first dose of {sup 177}Lu-octreotate but at early follow-up the only major haematological toxicity was a single case of grade 4 lymphopaenia. Both the presence of bone metastases and the administration of chemotherapy tended to result in greater reduction in blood counts, but these differences did not reach statistical significance. On long-term follow-up, 16 patients (59%) are alive with median overall survival of 36 months (32-44 months from first {sup 177}Lu-octreotate therapy). None of the recorded deaths was directly related to treatment toxicity. One patient had late grade 4 anaemia and thrombocytopaenia secondary to bone marrow failure from progressive infiltration by tumour. No other significant long-term haematological toxicities were recorded and no leukaemia was observed. No renal toxicity was observed on serial serum creatinine or radionuclide glomerular filtration rate (GFR) determination on initial or long-term follow-up. {sup 177}Lu-octreotate is a safe and well-tolerated therapy for patients who have previously been treated with {sup 111}In-pentetreotide and can

  15. Civilsamfundets ABC: H for Handling

    DEFF Research Database (Denmark)

    Lund, Anker Brink; Meyer, Gitte

    2015-01-01

    Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling.......Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling....

  16. The technique on handling radiation

    International Nuclear Information System (INIS)

    1997-11-01

    This book describes measurement of radiation and handling radiation. The first part deals with measurement of radiation. The contents of this part are characteristic on measurement technique of radiation, radiation detector, measurement of energy spectrum, measurement of radioactivity, measurement for a level of radiation and county's statistics on radiation. The second parts explains handling radiation with treating of sealed radioisotope, treating unsealed source and radiation shield.

  17. Uranium hexafluoride handling

    International Nuclear Information System (INIS)

    1991-01-01

    The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF 6 from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride

  18. Validation of Autoclave Protocols for Successful Decontamination of Category A Medical Waste Generated from Care of Patients with Serious Communicable Diseases.

    Science.gov (United States)

    Garibaldi, Brian T; Reimers, Mallory; Ernst, Neysa; Bova, Gregory; Nowakowski, Elaine; Bukowski, James; Ellis, Brandon C; Smith, Chris; Sauer, Lauren; Dionne, Kim; Carroll, Karen C; Maragakis, Lisa L; Parrish, Nicole M

    2017-02-01

    In response to the Ebola outbreak in 2014, many hospitals designated specific areas to care for patients with Ebola and other highly infectious diseases. The safe handling of category A infectious substances is a unique challenge in this environment. One solution is on-site waste treatment with a steam sterilizer or autoclave. The Johns Hopkins Hospital (JHH) installed two pass-through autoclaves in its biocontainment unit (BCU). The JHH BCU and The Johns Hopkins biosafety level 3 (BSL-3) clinical microbiology laboratory designed and validated waste-handling protocols with simulated patient trash to ensure adequate sterilization. The results of the validation process revealed that autoclave factory default settings are potentially ineffective for certain types of medical waste and highlighted the critical role of waste packaging in successful sterilization. The lessons learned from the JHH validation process can inform the design of waste management protocols to ensure effective treatment of highly infectious medical waste. Copyright © 2017 American Society for Microbiology.

  19. Assessing the interplay between the shoulders and low back during manual patient handling techniques in a nursing setting.

    Science.gov (United States)

    Belbeck, Alicia; Cudlip, Alan C; Dickerson, Clark R

    2014-01-01

    The purpose of this research was to quantify shoulder demands during freestyle manual patient handling (MPH) tasks and determine whether approaches intended to prevent low back injury increased shoulder demands. Twenty females completed 5 MPH tasks found commonly in hospital settings before and after a training session using current workplace MPH guidelines. Most normalized muscle activity indices and ratings of perceived exertion decreased following training at both the low back and shoulders, but were more pronounced at the low back. There was little evidence to suggest that mechanical demands were transferred from the low back to the shoulders following the training session. The study generally supports continued use of the recommended MPH techniques, but indicates that several tasks generate high muscular demands and should be avoided if possible.

  20. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  1. General anesthesia and postoperative pain management in analgesic intolerant patients with/without asthma: is it safe?

    Science.gov (United States)

    Celiker, V; Basgül, E; Karakaya, G; Oguzalp, H; Bozkurt, B; Kalyoncu, A F

    2004-01-01

    Analgesic intolerance (AI) appears in approximately 1 % of the general population. The triad of bronchial asthma, nasal polyposis, and analgesic intolerance is called analgesic-induced asthma (AIA). These patients are frequently referred to adult allergy clinics for preoperative evaluation for possible analgesic cross reactivity and intolerance to anesthetic agents. To determine allergic problems related to anesthesia and postoperative pain management in AI patients with and without asthma. The medical records of 45 patients who had been diagnosed with AI between January 1991 and December 2002 in the adult allergy unit and who underwent surgery in the same hospital in the last 4 years were retrospectively analyzed. The mean age of the patients was 44.4 13.4 years and 30 (66.6 %) were female. Thirty-six (80 %) had AIA, 34 (75.6 %) had persistent allergic rhinitis and 21 (46.7 %) had nasal polyps. Fifty-one surgical procedures were performed in 45 patients, in whom ear, nose and throat surgery was the main procedure (64.7 %). Anesthesia was induced with propofol, fentanyl, and vecuronium and was maintained by sevoflurane or isoflurane. Fentanyl was used for early postoperative pain relief. No complications appeared in relation to anesthesia or early pain management except in a 44-year-old AIA woman who had a reaction in the postoperative period after receiving an inappropriate analgesic. None of the patients had anesthesia-related allergic problems. Atropine and diazepam in the premedication, propofol and fentanyl during induction, muscle relaxation facilitation by vecuronium, and sevoflurane or isoflurane for maintenance seem to be a safe general anesthetic choice for analgesic intolerant patients with and without asthma.

  2. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  3. SAFE Newsletter

    OpenAIRE

    2013-01-01

    The Center of Excellence SAFE – “Sustainable Architecture for Finance in Europe” – is a cooperation of the Center for Financial Studies and Goethe University Frankfurt. It is funded by the LOEWE initiative of the State of Hessen (Landes-Offensive zur Entwicklung wissenschaftlich-ökonomischer Exzellenz). SAFE brings together more than 40 professors and just as many junior researchers who are all dedicated to conducting research in support of a sustainable financial architecture. The Center has...

  4. ATA diagnostic data handling system: an overview

    International Nuclear Information System (INIS)

    Chambers, F.W.; Kallman, J.; McDonald, J.; Slominski, M.

    1984-01-01

    The functions to be performed by the ATA diagnostic data handling system are discussed. The capabilities of the present data acquisition system (System 0) are presented. The goals for the next generation acquisition system (System 1), currently under design, are discussed. Facilities on the Octopus system for data handling are reviewed. Finally, we discuss what has been learned about diagnostics and computer based data handling during the past year

  5. Written advice can provide a safe and acceptable alternative to new patient assessment for selected referrals to haematologists.

    Science.gov (United States)

    Ganly, Peter S; Keeman, Helen; Spearing, Ruth L; Smith, Mark P; Patton, Nigel; Merriman, Eileen G; Gibbons, Steve S

    2008-01-07

    To measure the safety and acceptability of providing written advice (WA) for selected patients referred to a haematology service, as an alternative to inpatient or outpatient assessment. Review of the initial management and subsequent course of patients newly referred to a tertiary referral hospital in Christchurch, New Zealand, between 16 October 2003 and 8 June 2006. Structured questionnaires were sent to all referring doctors and patients recently managed with WA. Numbers and diagnoses of patients managed with WA, early assessment or delayed assessment; re-referral and treatment details; characteristics of WA letters; and opinions of referring doctors and their patients on the WA process. 26% of new referrals (714/2785) were managed with prompt WA, while 16% (455/2785) received the alternative of delayed assessment. After a median follow-up of 23 months (range, 8-40 months), 13% of those managed with WA (91/714) were re-referred back to the same haematologists; 7% (52/714) were assessed in hospital and 2% (15/714) eventually required treatment. There were no deaths due to haematological causes. Over 90% of responding referring doctors said the WA process was rapid and effective, and 77% of recently managed patients were pleased to be treated by their own doctors. Using WA to manage a substantial minority of patients referred to haematologists can be rapid and safe. It is widely accepted by referring doctors.

  6. Human Mesenchymal Stem Cell Transfusion Is Safe and Improves Liver Function in Acute-on-Chronic Liver Failure Patients

    Science.gov (United States)

    Shi, Ming; Zhang, Zheng; Xu, Ruonan; Lin, Hu; Fu, Junliang; Zou, Zhengsheng; Zhang, Aimin; Shi, Jianfei; Chen, Liming; Lv, Sa; He, Weiping; Geng, Hua; Jin, Lei; Liu, Zhenwen

    2012-01-01

    Acute-on-chronic liver failure (ACLF) is a severe, life-threatening complication, and new and efficient therapeutic strategies for liver failure are urgently needed. Mesenchymal stem cell (MSC) transfusions have been shown to reverse fulminant hepatic failure in mice and to improve liver function in patients with end-stage liver diseases. We assessed the safety and initial efficacy of umbilical cord-derived MSC (UC-MSC) transfusions for ACLF patients associated with hepatitis B virus (HBV) infection. A total of 43 ACLF patients were enrolled for this open-labeled and controlled study; 24 patients were treated with UC-MSCs, and 19 patients were treated with saline as controls. UC-MSC therapy was given three times at 4-week intervals. The liver function, adverse events, and survival rates were evaluated during the 48-week or 72-week follow-up period. No significant side effects were observed during the trial. The UC-MSC transfusions significantly increased the survival rates in ACLF patients; reduced the model for end-stage liver disease scores; increased serum albumin, cholinesterase, and prothrombin activity; and increased platelet counts. Serum total bilirubin and alanine aminotransferase levels were significantly decreased after the UC-MSC transfusions. UC-MSC transfusions are safe in the clinic and may serve as a novel therapeutic approach for HBV-associated ACLF patients. PMID:23197664

  7. Automation of 3D micro object handling process

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Hansen, Hans Nørgaard

    2007-01-01

    Most of the micro objects in industrial production are handled with manual labour or in semiautomatic stations. Manual labour usually makes handling and assembly operations highly flexible, but slow, relatively imprecise and expensive. Handling of 3D micro objects poses special challenges due to ...

  8. [Time to bury the adrenaline-myth!--Safe use of adrenaline anesthesia in hand surgery and orthopedics].

    Science.gov (United States)

    Hagert, Elisabet; Lalonde, Donald

    2015-02-03

    The epinephrine myth originated in the 1940s, when acidic (pH 1) procaine-epinephrine was injected into fingers, causing finger necrosis. Today, level 1 evidence exists for the safe use of epinephrine in fingers. The ability to use lidocaine-epinephrine in hand surgery and orthopedics eliminates the need for a tourniquet, or "bloodless field". Surgery using Wide Awake, Lidocaine-epinephrine Anesthesia, No Tourniquet (WALANT) reduces patient discomfort, facilitates patient participation in surgery, improves safe outcomes following reconstructions and greatly reduces the cost of medical care. Furthermore, patients regarded as high-risk can be safely treated without risk of cardiac or pulmonary side effects. In this manuscript, the background of the epinephrine myth is described, as well as recommended use of WALANT in hand surgery and orthopedics.

  9. Nordic Walking May Safely Increase the Intensity of Exercise Training in Healthy Subjects and in Patients with Chronic Heart Failure.

    Science.gov (United States)

    Lejczak, Andrzej; Josiak, Krystian; Węgrzynowska-Teodorczyk, Kinga; Rudzińska, Eliza; Jankowska, Ewa A; Banasiak, Waldemar; Piepoli, Massimo F; Woźniewski, Marek; Ponikowski, Piotr

    2016-01-01

    Physical activity in patients with chronic heart failure (HF) improves the exercise capacity and quality of life, and may also reduce mortality and hospitalizations. The greatest benefits are achieved through high-intensity aerobic exercises resulting in a stronger cardiorespiratory response. Nordic walking (NW), a walking technique using two poles and mimicking the movements performed while cross-country skiing, is associated with the involvement of more muscle groups than in the case of classic walking, and should therefore make it possible to increase exercise intensity, resulting in more effective training for patients with HF. The aim of the study was to assess the feasibility and safety of the NW technique, and to compare the effort intensity while walking with and without the NW technique in both healthy subjects and in patients with chronic HF. The study involved 12 healthy individuals (aged 30 ± 10 years, 5 men) and 12 men with stable chronic systolic HF (aged 63 ± 11 years, all categorized in New York Heart Association class II, median LVEF 30%, median peak VO(2) 18.25 mL/kg/min). All the participants completed two randomly assigned submaximal walking tests (one with NW poles and one without) conducted on a level treadmill for 6 min at a constant speed of 5 km/h. Walking with the NW technique was feasible, safe and well tolerated in all subjects. In both the control group and the chronic HF group, walking with the NW technique increased peak VO(2), RER, VE, PET CO(2), HR and SBP over walking without the poles; and the fatigue grade according to the abridged Borg scale was higher. Dyspnea did not increase significantly with the NW technique. The NW technique can increase the intensity of aerobic training in a safe and well-tolerated way in both healthy individuals and in patients with chronic HF.

  10. Design and evaluation of a new ergonomic handle for instruments in minimally invasive surgery.

    Science.gov (United States)

    Sancibrian, Ramon; Gutierrez-Diez, María C; Torre-Ferrero, Carlos; Benito-Gonzalez, Maria A; Redondo-Figuero, Carlos; Manuel-Palazuelos, Jose C

    2014-05-01

    Laparoscopic surgery techniques have been demonstrated to provide massive benefits to patients. However, surgeons are subjected to hardworking conditions because of the poor ergonomic design of the instruments. In this article, a new ergonomic handle design is presented. This handle is designed using ergonomic principles, trying to provide both more intuitive manipulation of the instrument and a shape that reduces the high-pressure zones in the contact with the surgeon's hand. The ergonomic characteristics of the new handle were evaluated using objective and subjective studies. The experimental evaluation was performed using 28 volunteers by means of the comparison of the new handle with the ring-handle (RH) concept in an instrument available on the market. The volunteers' muscle activation and motions of the hand, wrist, and arm were studied while they performed different tasks. The data measured in the experiment include electromyography and goniometry values. The results obtained from the subjective analysis reveal that most volunteers (64%) preferred the new prototype to the RH, reporting less pain and less difficulty to complete the tasks. The results from the objective study reveal that the hyperflexion of the wrist required for the manipulation of the instrument is strongly reduced. The new ergonomic handle not only provides important ergonomic advantages but also improves the efficiency when completing the tasks. Compared with RH instruments, the new prototype reduced the high-pressure areas and the extreme motions of the wrist. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Moderate glycemic control safe in critically ill adult burn patients: A 15 year cohort study.

    Science.gov (United States)

    Stoecklin, Patricia; Delodder, Frederik; Pantet, Olivier; Berger, Mette M

    2016-02-01

    Hyperglycemia is a metabolic alteration in major burn patients associated with complications. The study aimed at evaluating the safety of general ICU glucose control protocols applied in major burns receiving prolonged ICU treatment. 15 year retrospective analysis of consecutive, adult burn patients admitted to a single specialized centre. death or length of stay burned surface (TBSA), severity scores, infections, ICU stay, outcome. Metabolic variables: total energy, carbohydrate and insulin delivery/24h, arterial blood glucose and CRP values. Analysis of 4 periods: 1, before protocol; 2, tight doctor driven; 3, tight nurse driven; 4, moderate nurse driven. 229 patients, aged 45 ± 20 years (mean ± SD), burned 32 ± 20% TBSA were analyzed. SAPSII was 35 ± 13. TBSA, Ryan and ABSI remained stable. Inhalation injury increased. A total of 28,690 blood glucose samples were analyzed: the median value remained unchanged with a narrower distribution over time. After the protocol initiation, the normoglycemic values increased from 34.7% to 65.9%, with a reduction of hypoglycaemic events (no extreme hypoglycemia in period 4). Severe hyperglycemia persisted throughout with a decrease in period 4 (9.25% in period 4). Energy and glucose deliveries decreased in periods 3 and 4 (pprotocol improved the glycemic control in adult burn patients, reducing glucose variability. Moderate glycemic control in burns was safe specifically related to hypoglycemia, reducing the incidence of hypoglycaemic events compared to the period before. Hyperglycemia persisted at a lower level. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  12. Nurses' clinical reasoning practices that support safe medication administration: An integrative review of the literature.

    Science.gov (United States)

    Rohde, Emily; Domm, Elizabeth

    2018-02-01

    To review the current literature about nurses' clinical reasoning practices that support safe medication administration. The literature about medication administration frequently focuses on avoiding medication errors. Nurses' clinical reasoning used during medication administration to maintain medication safety receives less attention in the literature. As healthcare professionals, nurses work closely with patients, assessing and intervening to promote mediation safety prior to, during and after medication administration. They also provide discharge teaching about using medication safely. Nurses' clinical reasoning and practices that support medication safety are often invisible when the focus is medication errors avoidance. An integrative literature review was guided by Whittemore and Knafl's (Journal of Advanced Nursing, 5, 2005 and 546) five-stage review of the 11 articles that met review criteria. This review is modelled after Gaffney et al.'s (Journal of Clinical Nursing, 25, 2016 and 906) integrative review on medical error recovery. Health databases were accessed and systematically searched for research reporting nurses' clinical reasoning practices that supported safe medication administration. The level and quality of evidence of the included research articles were assessed using The Johns Hopkins Nursing Evidence-Based Practice Rating Scale©. Nurses have a central role in safe medication administration, including but not limited to risk awareness about the potential for medication errors. Nurses assess patients and their medication and use knowledge and clinical reasoning to administer medication safely. Results indicated nurses' use of clinical reasoning to maintain safe medication administration was inadequately articulated in 10 of 11 studies reviewed. Nurses are primarily responsible for safe medication administration. Nurses draw from their foundational knowledge of patient conditions and organisational processes and use clinical reasoning that

  13. Day surgery is effective and safe for patients with great saphenous ...

    African Journals Online (AJOL)

    However, average hospital stays in DS group was 1 day, compared to 4.2 days in IS group. Moreover with respect to average medical cost (dollar), it was 780.33 dollars and 1021.06 dollars in DS and IS group, respectively. Conclusion: DS for GSVV is an effective and safe procedure, which was the same as IS. However ...

  14. Scheduling of outbound luggage handling at airports

    DEFF Research Database (Denmark)

    Barth, Torben C.; Pisinger, David

    2012-01-01

    This article considers the outbound luggage handling problem at airports. The problem is to assign handling facilities to outbound flights and decide about the handling start time. This dynamic, near real-time assignment problem is part of the daily airport operations. Quality, efficiency......). Another solution method is a decomposition approach. The problem is divided into different subproblems and solved in iterative steps. The different solution approaches are tested on real world data from Frankfurt Airport....

  15. Sequence trajectory generation for garment handling systems

    OpenAIRE

    Liu, Honghai; Lin, Hua

    2008-01-01

    This paper presents a novel generic approach to the planning strategy of garment handling systems. An assumption is proposed to separate the components of such systems into a component for intelligent gripper techniques and a component for handling planning strategies. Researchers can concentrate on one of the two components first, then merge the two problems together. An algorithm is addressed to generate the trajectory position and a clothes handling sequence of clothes partitions, which ar...

  16. Enhanced wood fuel handling: market and design studies

    Energy Technology Data Exchange (ETDEWEB)

    Landen, R.; Rippengal, R.; Redman, A.N.

    1997-09-01

    This report examines the potential for the manufacture and sale of novel wood fuel handling systems as a means of addressing users' concerns regarding current capital costs and potential high labour costs of non-automated systems. The report considers fuel handling technology that is basically appropriate for wood-fired heating systems of between c.100kW and c.1MW maximum continuous rating. This report details work done by the project collaborators in order to: (1) assess the current status of wood fuel handling technology; (2) evaluate the market appetite for improved wood fuel handling technology; (3) derive capital costs which are acceptable to customers; (4) review design options; and (5) select one or more design options worthy of further development. The current status of wood fuel handling technology is determined, and some basic modelling to give guidance on acceptable capital costs of 100-1000kW wood fuel handling systems is undertaken. (author)

  17. A study on characterization and evaluation methodologies of radioactive waste forms for safe disposal

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Y. C.; Lee, G. S.; Kim, G. J.; Nam, H.; Seok, J. H. [Yonsei Univ., Seoul (Korea, Republic of)

    2004-02-15

    The contents and scope of the study are summarized as follows : elicitation of significant items for characteristic assessment about stability analysis of radioactive waste forms for safe disposal, compressive strength, free water, leaching rate, and weatherability. Suggestion of assessment methods through the characteristic test of waste forms, comparison of assessment methods and suggestion of suitable testing methods about the above stated 4 items. Assessment modeling development for long-term stability of radioactive waste forms, weatherometric test of waste forms, expectation modeling development through VOM(Valance-Oxygen Model). Suggestion of determination standard together assessment testing methods and description about the standard. Explanation to be suitable guideline and regulation of waste handling and acceptance.

  18. Safety issues in the handling of radiation sources in category IV gamma radiation facilities

    International Nuclear Information System (INIS)

    Kohli, A.K.

    2002-01-01

    There is potential for incidents/accidents related to handling of radiation sources. This is increasing due to the fact that more number of plants that too with much larger levels of activity are now coming up. Such facilities produce very high levels of exposure rates during irradiation. A person accidentally present in the irradiation cell can receive a lethal dose within a very short time. Apart from safety requirements during operation and maintenance of these facilities, safety during loading and unloading of sources is important. Category IV type irradiators are the most common. Doubly encapsulated Co-60 slugs are employed to form the source pencils. These irradiators employ a water pool for safely storing the source pencils when irradiation of the products is not going on or when human access is needed into the irradiation cell for some maintenance or source loading/unloading operations. Safety during loading/unloading operations of source pencils is important. In design itself care needs to be taken such that all such operations are convenient and any incident will not lead to a situation where it becomes difficult to come out. Different situations, which can arise during handling of radiation sources and suggested designs to obviate such tight situations, are discussed. (Author)

  19. Medication impairing safe driving: knowledge, attitude and behaviour of consumers and patients.

    NARCIS (Netherlands)

    Vervloet, M.; Dijk, L. van

    2007-01-01

    Background: Promoting road safety is one of the aims of the Dutch road safety policy. The role of medication impairing safe driving (tranquilizers, sleep medication, tricyclic antidepressants and first generation antihistamines) in traffic accidents is underexposed and not well known. Previous

  20. Remote handling for an ISIS target change

    International Nuclear Information System (INIS)

    Broome, T.A.; Holding, M.

    1989-01-01

    During 1987 two ISIS targets were changed. This document describes the main features of the remote handling aspects of the work. All the work has to be carried out using remote handling techniques. The radiation level measured on the surface of the reflector when the second target had been removed was about 800 mGy/h demonstrating that hands on operations on any part of the target reflector moderator assembly is not practical. The target changes were the first large scale operations in the Target Station Remote Handling Cell and a great deal was learned about both equipment and working practices. Some general principles emerged which are applicable to other active handling tasks on facilities like ISIS and these are discussed below. 8 figs

  1. Incorporating Handling Qualities Analysis into Rotorcraft Conceptual Design

    Science.gov (United States)

    Lawrence, Ben

    2014-01-01

    This paper describes the initial development of a framework to incorporate handling qualities analyses into a rotorcraft conceptual design process. In particular, the paper describes how rotorcraft conceptual design level data can be used to generate flight dynamics models for handling qualities analyses. Also, methods are described that couple a basic stability augmentation system to the rotorcraft flight dynamics model to extend analysis to beyond that of the bare airframe. A methodology for calculating the handling qualities characteristics of the flight dynamics models and for comparing the results to ADS-33E criteria is described. Preliminary results from the application of the handling qualities analysis for variations in key rotorcraft design parameters of main rotor radius, blade chord, hub stiffness and flap moment of inertia are shown. Varying relationships, with counteracting trends for different handling qualities criteria and different flight speeds are exhibited, with the action of the control system playing a complex part in the outcomes. Overall, the paper demonstrates how a broad array of technical issues across flight dynamics stability and control, simulation and modeling, control law design and handling qualities testing and evaluation had to be confronted to implement even a moderately comprehensive handling qualities analysis of relatively low fidelity models. A key outstanding issue is to how to 'close the loop' with an overall design process, and options for the exploration of how to feedback handling qualities results to a conceptual design process are proposed for future work.

  2. Quicker yet safe: skeletonization of 1640 internal mammary arteries with harmonic technology in 965 patients.

    Science.gov (United States)

    Kieser, Teresa M; Rose, M Sarah; Aluthman, Uthman; Narine, Kishan

    2014-05-01

    Skeletonization of the internal mammary artery (IMA) facilitates arterial grafting and has been shown to reduce deep sternal infection but is more time-consuming and tedious than pedicle harvest. We wished to determine if use of harmonic technology (HT) facilitates skeletonization of the IMA and is as safe as the conventional technique of skeletonization. In a consecutive series of 1057 patients with isolated coronary artery bypass graft (CABG) surgery from 2003 to 2013, adverse events and recorded harvest times were compared between harmonic (965 patients) and non-harmonic patients (86 patients). HT was used to harvest 1640 IMAs in 965 (91%) of 1057 consecutive CABG patients and skeletonization with the traditional technique (use of an electrocautery tip as a dissector) was used to harvest 147 IMAs in 86 patients. Six patients had no IMA harvested with this surgery (4 patients had an IMA used from a previous CABG, 1 had no disease of the left anterior descending coronary artery and 1 patient was in cardiogenic shock precluding IMA use). Excluding patients with single-vessel disease, 730/987 (74%) of patients received bilateral IMAs. Demographics of patients with and without harmonic skeletonization, respectively, were the following: mean age: 64.7 vs 67.7 years; diabetes: 33 vs 34%; women: 21 vs 26% and median European System for Cardiac Operative Risk Evaluation: 2.9 vs 3.2. The mean harvest time for 77 non-harmonic skeletonized mammary arteries (49 surgeries) was 32.2 min (95% confidence interval (CI): 30.1, 34.3), for harmonic skeletonized arteries after 450 surgeries was 28.4 min, (95% CI: 27.8, 29.1) and in the last 100 IMAs harvested for the isolated harmonic device use/mammary was 15.4 min (95% CI: 14.0, 16.7). Major adverse events for patients with and without harmonic skeletonization, respectively, were: reoperation for bleeding: 2.7 vs 3.5% (difference = 0.8%, 95% CI: -3.2, 4.8); damaged mammaries: 0.4 vs 0.7% (difference = 0.3%, 95% CI: -1.0, 1.7); deep

  3. Sailing a safe ship: improving patient safety by enhancing the leadership skills of new consultant specialist surgeons.

    Science.gov (United States)

    Shah, Peter; Cross, Vinette; Sii, Freda

    2013-01-01

    The potential for "discontinuities in care" arising from the turbulent transition from specialist trainee to consultant specialist presents risks to patient safety. But it is easy to lose sight of the affective needs of individuals facing the burden of keeping patients safe. This article describes a 2-day program focused on new and prospective consultant specialist ophthalmic surgeons entitled "Sailing a Safe Ship" (SASS). The purpose was to facilitate understanding and analysis of their personal holistic learning needs and enhance individual agency in optimizing learning during the transition period. The program used gaming, team challenges, meta-planning, role play and professional actors, interactive presentations, and self-analysis tools to portray the real world of consultant specialist practice in terms of ill-defined problems requiring "elite communication" and effective negotiation of value differences and priorities for their resolution. Participants' insights into their individual learning were recorded in scheduled reflective sessions. The immediate impact on their learning was also considered in terms of direct (instructional) and indirect (nurturant) effects. Participants' insights reflected 4 key themes: admitting vulnerability and uncertainty, taking responsibility for managing risk, being self-aware and reflexive, and internalizing authentic leadership. Four instructional and 4 nurturant effects were revealed. Preliminary findings on long-term impact on participants' practice are outlined. Evidence from the evaluation indicated that participants felt empowered to construct a personal strategic response to unfamiliar and unanticipated workplace demands and pressures, adopt a capability mindset that would accelerate their capacity to fulfill an enhanced leadership role, and take a holistic approach to their continuing self-directed development as leaders and educators. Copyright © 2013 The Alliance for Continuing Education in the Health Professions

  4. How safe is deep sedation or general anesthesia while providing dental care?

    Science.gov (United States)

    Bennett, Jeffrey D; Kramer, Kyle J; Bosack, Robert C

    2015-09-01

    Deep sedation and general anesthesia are administered daily in dental offices, most commonly by oral and maxillofacial surgeons and dentist anesthesiologists. The goal of deep sedation or general anesthesia is to establish a safe environment in which the patient is comfortable and cooperative. This requires meticulous care in which the practitioner balances the patient's depth of sedation and level of responsiveness while maintaining airway integrity, ventilation, and cardiovascular hemodynamics. Using the available data and informational reports, the authors estimate that the incidence of death and brain injury associated with deep sedation or general anesthesia administered by all dentists most likely exceeds 1 per month. Airway compromise is a significant contributing factor to anesthetic complications. The American Society of Anesthesiology closed claim analysis also concluded that human error contributed highly to anesthetic mishaps. The establishment of a patient safety database for anesthetic management in dentistry would allow for a more complete assessment of morbidity and mortality that could direct efforts to further increase safe anesthetic care. Deep sedation and general anesthesia can be safely administered in the dental office. Optimization of patient care requires appropriate patient selection, selection of appropriate anesthetic agents, utilization of appropriate monitoring, and a highly trained anesthetic team. Achieving a highly trained anesthetic team requires emergency management preparation that can foster decision making, leadership, communication, and task management. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  5. Development of tritium-handling technique

    International Nuclear Information System (INIS)

    Ohmura, Hiroshi; Hosaka, Akio; Okamoto, Takahumi

    1988-01-01

    The overview of developing activities for tritium-handling techniques in IHI are presented. To establish a fusion power plant, tritium handling is one of the key technologies. Recently in JAERI, conceptual design of FER (Fusion Experimental Reactor) has been carried out, and the FER system requires a processing system for a large amount of tritium. IHI concentrate on investigation of fuel gas purification, isotope separation and storage systems under contract with Toshiba Corporation. Design results of the systems and each components are reviewed. IHI has been developing fundamental handling techniques which are the ZrNi bed for hydrogen isotope storage and isotope separation by laser. The ZrNi bed with a tritium storage capacity of 1000 Ci has been constructed and recovery capability of the hydrogen isotope until 10 -4 Torr {0.013 Pa} was confirmed. In laser isotope separation, the optimum laser wave length has been determined. (author)

  6. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  7. Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material. Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2010-01-01

    This Safety Guide provides recommendations on achieving and demonstrating compliance with IAEA Safety Standards Series No. TS-R-1, Regulations for the Safe Transport of Radioactive Material, 2005 Edition, establishing safety requirements to be applied to the national and international transport of radioactive material. Transport is deemed to comprise all operations and conditions associated with and involved in the movement of radioactive material; these include the design, fabrication and maintenance of packaging, and the preparation, consigning, handling, carriage, storage in transit and receipt at the final destination of packages. This publication supersedes IAEA Safety Series No. TS-G-1.1, 2002 Edition

  8. How to improve communication for the safe use of medicines?: Discussions on social marketing and patient-tailored approaches at the annual meetings of the WHO Programme for International Drug Monitoring.

    Science.gov (United States)

    Bahri, Priya; Harrison-Woolrych, Mira

    2012-12-01

    Over the past decade, the annual meetings of national centres participating in the WHO Programme for International Drug Monitoring have increasingly included discussions on how to improve communication between national pharmacovigilance centres, patients, healthcare professionals, policy makers and the general public, with the aim of promoting the safe use of medicines. At the most recent meetings, working groups were dedicated to discuss possible applications and implementation of social marketing and patient-tailored approaches. This article provides the history and a summary of the recent discussions and recommendations to support progress in this respect at national and global level. Recommendations are made to investigate and pilot these approaches in small-scale projects at national pharmacovigilance centres. Applying elements from the social marketing and patient-tailored approaches to support behaviours of safe medicines use in patients and healthcare professionals should give the pharmacovigilance community new tools to achieve their goal to minimize risks with medicines and improve patient safety.

  9. Safe Grid

    Science.gov (United States)

    Chow, Edward T.; Stewart, Helen; Korsmeyer, David (Technical Monitor)

    2003-01-01

    The biggest users of GRID technologies came from the science and technology communities. These consist of government, industry and academia (national and international). The NASA GRID is moving into a higher technology readiness level (TRL) today; and as a joint effort among these leaders within government, academia, and industry, the NASA GRID plans to extend availability to enable scientists and engineers across these geographical boundaries collaborate to solve important problems facing the world in the 21 st century. In order to enable NASA programs and missions to use IPG resources for program and mission design, the IPG capabilities needs to be accessible from inside the NASA center networks. However, because different NASA centers maintain different security domains, the GRID penetration across different firewalls is a concern for center security people. This is the reason why some IPG resources are been separated from the NASA center network. Also, because of the center network security and ITAR concerns, the NASA IPG resource owner may not have full control over who can access remotely from outside the NASA center. In order to obtain organizational approval for secured remote access, the IPG infrastructure needs to be adapted to work with the NASA business process. Improvements need to be made before the IPG can be used for NASA program and mission development. The Secured Advanced Federated Environment (SAFE) technology is designed to provide federated security across NASA center and NASA partner's security domains. Instead of one giant center firewall which can be difficult to modify for different GRID applications, the SAFE "micro security domain" provide large number of professionally managed "micro firewalls" that can allow NASA centers to accept remote IPG access without the worry of damaging other center resources. The SAFE policy-driven capability-based federated security mechanism can enable joint organizational and resource owner approved remote

  10. Changes in serial laboratory test results in snakebite patients: when can we safely exclude envenoming?

    Science.gov (United States)

    Ireland, Graham; Brown, Simon G A; Buckley, Nicholas A; Stormer, Jeff; Currie, Bart J; White, Julian; Spain, David; Isbister, Geoffrey K

    2010-09-06

    To determine which laboratory tests are first associated with severe envenoming after a snakebite, when (ie, how long after the bite) the test results become abnormal, and whether this can determine a safe observation period after suspected snakebite. Prospective cohort study of 478 patients with suspected or confirmed snakebite recruited to the Australian Snakebite Project from January 2002 to April 2009, who had at least three sets of laboratory test results and at least 12 hours of observation in hospital after the bite. Severe envenoming was defined as venom-induced consumption coagulopathy (VICC), myotoxicity, neurotoxicity or thrombotic microangiopathy. International normalised ratio (INR), activated partial thromboplastin time (aPTT), creatine kinase (CK) level, and neurological examination. There were 240 patients with severe envenoming, 75 with minor envenoming and 163 non-envenomed patients. Of 206 patients with VICC, 178 had an INR > 1.2 (abnormal) on admission, and the remaining 28 had an INR > 1.2 within 12 hours of the bite. Of 33 patients with myotoxicity, a combination of CK > 250 U/L and an abnormal aPTT identified all but two cases by 12 hours; one of these two was identified within 12 hours by leukocytosis. Nine cases of isolated neurotoxicity had a median time of onset after the bite of 4 hours (range, 35 min - 12 h). The combination of serial INR, aPTT and CK tests and repeated neurological examination identified 213 of 222 severe envenoming cases (96%) by 6 hours and 238 of 240 (99%) by 12 hours. Laboratory parameters (INR, aPTT and CK) and neurological reassessments identified nearly all severe envenoming cases within 12 hours of the bite, even in this conservative analysis that assumed normal test results if the test was not done.

  11. Investigation and analysis the vibration of handles of chainsaw without cutting

    Directory of Open Access Journals (Sweden)

    M Feyzi

    2016-04-01

    (VMI-192. The accelerometer mounted on an adapter inserted between the handle and accelerometer. The experiments were conducted in split plot completely randomized design. Ninety tests in two handles, three speeds of engine, three perpendicular axes and five repeats were conducted. The vibration acceleration at various conditions was measured and the root mean square of vibration acceleration was calculated based on acceleration-time spectrum. To investigate the characteristics of vibration in different speeds, the vibration spectrums in time domain were converted to spectrums in frequency domain. The frequency weighted RMS acceleration at 1/3rd octave bands from 6.3Hz to 1250Hz and the vibration total value was calculated from frequency spectrum. To analyze the obtained data, SAS software was used. Furthermore, the Duncan's multiple range tests were used to compare the RMS values. Results and Discussion: Main source of vibration of chainsaw was single cylinder engine. The acceleration spectra of employed chainsaw had peaks in frequencies in accordance with the speed of engine. These peaks in 2800 rpm, 10000 rpm and 13300 rpm speeds of engine occurred in 46.5Hz, 166.5Hz and 221.5Hz, respectively. To achieve a safe design for handle of portable tools, identifying the frequency which leads to the maximum value of vibration acceleration is very useful. To avoid the resonance phenomenon, the natural frequency of handle must be far from dominant frequency of engine. The results of ANOVA showed that the RMS acceleration in different axes and different speeds were significant at 1% level. The maximum value of vibration acceleration, at idling engine speed, occurred in the lateral axis. In addition, the mentioned variable was maximized in normal and axial axes at nominal and racing speeds, respectively. The total value of vibration was increased when the speed of engine moving away from nominal speed. This increase in rear handle is very larger than front handle. The total

  12. Waste Handling Shaft concrete liner degradation conclusions and recommendations

    International Nuclear Information System (INIS)

    1992-10-01

    The primary function of the Waste Handling Shaft (WHS) at the Waste Isolation Pilot Plant (WIPP) is to permit the transfer of radioactive waste from the surface waste handling building to the underground storage area. It also serves as an intake shaft for small volumes of air during normal storage operations and as an emergency escape route. Part of the construction was the placement of a concrete liner and steel reinforced key in 1984. During a routine shaft inspection in May 1990, some degradation of the WHS concrete liner was observed between the depths of 800 and 900 feet below the ground surface. Detailed investigations of the liner had been carried out by Sandia National Laboratories and by Westinghouse Electric Corporation Waste Isolation Division (WID) through Lankard Materials Laboratory. Observations, reports, and data support the conclusion that the concrete degradation, resulting from attack by chemically aggressive brine, is a localized phenomena. It is the opinion of the WID that the degradation is not considered an immediate or near term concern; this is supported by technical experts. WID recommendations have been made which, when implemented, will ensure an extended liner life. Based on the current assessment of available data and the proposed shaft liner monitoring program described in this report, it is reasonable to assume that the operational life of the concrete shaft liner can safely support the 25-year life of the WIPP. Analysis of data indicates that degradation of the shaft's concrete liner is attributed to chemically aggressive brine seeping through construction joints and shrinkage cracks from behind the liner in and around the 834-foot depth. Chemical and mechanical components of concrete degradation have been identified. Chemical attack is comprised of several stages of concrete alteration. The other component, mechanical degradation, results from the expansive forces of crystals forming in the concrete pore space

  13. in Critically Ill Patients: Success and Limits

    Directory of Open Access Journals (Sweden)

    Filippo Mariano

    2011-01-01

    Full Text Available Citrate anticoagulation has risen in interest so it is now a real alternative to heparin in the ICUs practice. Citrate provides a regional anticoagulation virtually restricted to extracorporeal circuit, where it acts by chelating ionized calcium. This issue is particularly true in patients ongoing CRRT, when the “continuous” systemic anticoagulation treatment is per se a relevant risk of bleeding. When compared with heparin most of studies with citrate reported a longer circuit survival, a lower rate of bleeding complications, and transfused packed red cell requirements. As anticoagulant for CRRT, the infusion of citrate is prolonged and it could potentially have some adverse effects. When citrate is metabolized to bicarbonate, metabolic alkalosis may occur, or for impaired metabolism citrate accumulation leads to acidosis. However, large studies with dedicated machines have indeed demonstrated that citrate anticoagulation is well tolerated, safe, and an easy to handle even in septic shock critically ill patients.

  14. How to Handle Impasses in Bargaining.

    Science.gov (United States)

    Durrant, Robert E.

    Guidelines in an outline format are presented to school board members and administrators on how to handle impasses in bargaining. The following two rules are given: there sometimes may be strikes, but there always will be settlements; and on the way to settlements, there always will be impasses. Suggestions for handling impasses are listed under…

  15. Overview of the performance of the JET active gas handling system during and after DTE1

    International Nuclear Information System (INIS)

    Laesser, R.; Atkins, G.; Bell, A.

    1999-02-01

    The JET Active Gas Handling System (AGHS) was designed, built and commissioned to handle safely radioactive tritium gas mixtures, to supply tritium (T 2 ) and deuterium (D 2 ) to the JET torus, to process the exhaust gases with the main purpose to enrich and re-use T 2 and D 2 , to detritiate tritiated impurities and to keep discharges far below the approved daily release limits. In addition, the AGHS had to supply the necessary ventilation air streams during maintenance or repair inside or outside of the AGHS building. During the first Deuterium-Tritium Experiment (DTE1) at JET in 1997 the AGHS fulfilled all these tasks in an excellent manner. No unauthorised or unplanned tritium releases occurred and no operational delays were caused by the AGHS. In fact, this was the first true demonstration that quantities of tritium in the tens of grams range can be processed and recycled safely and efficiently in a large fusion device. At the start of DTE1 20 g of tritium were available on the JET site. About 100 g of tritium were supplied from the AGHS to the users which necessitated the recycling of tritium at least five times. Approximately 220 tritium plasma shots were performed during DTE1. Large amounts of tritium were temporarily trapped in the torus. This overview presents the performance of the whole AGHS during DTE1 as well as general aspects such as the preparation for DTE1; the quantities of gases supplied from the AGHS to the users and pumped back to the AGHS; tritium accountancy; interlock systems; failure of equipment; and gives detailed information of the gas processing in each subsystem of the AGHS. As a consequence of the performance of the AGHS during DTE1 we can state confidently that the AGHS is ready for further Deuterium-Tritium Experiments. (author)

  16. Nurses' Experiences in Safe Handling of Chemotherapeutic Agents: The Taiwan Case.

    Science.gov (United States)

    Chen, Hai-Chiao; Lu, Zxy-Yann Jane; Lee, Shu-Hui

    2016-01-01

    Nurses are the least compliant with the guidelines for use of personal protective equipment (PPE) among health professionals. While the literature regarding nurses not following the guidelines focuses on nonuse of PPE, the experiences of using PPE from nurses' perspectives have not been examined. The aim of this study was to explore the concerns of nurses regarding their decision to use or not to use PPE in the cultural context of Taiwan. An ethnographic design was used, and ethnographic interviews of 57 nurses working with chemotherapy for more than 2 years were conducted. The participating nurses were observed in 2 accredited medical centers with oncology care teams in Taiwan. The constant comparison method was applied for data analysis, and cultural themes were generated from all transcripts. Wearing PPE was identified as an obstacle to professional image and performance. Nurses transformed safety into efficiency and prioritized social roles over professional roles. Experienced nurses, as insiders, believed that they have gained clinical wisdom to avoid occupational exposure to chemotherapy toxicity. This study explored the characteristics of clinical wisdom regarding PPE use in the context of Taiwanese chemotherapy care. Perceived professional image, efficiency on the job, PPE cost, and hospital rules influenced the use or nonuse of PPE by oncology care nurses. Acceptable nurse-patient ratios and refraining from chemotherapy toxicity exposure for pregnant and breast-feeding women are advocated for policy making. The experiential expertise of nurses should be shared as credible evidence in developing guidelines.

  17. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  18. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  19. Interventions to Improve Safe Sleep Among Hospitalized Infants at Eight Children's Hospitals.

    Science.gov (United States)

    Kuhlmann, Stephanie; Ahlers-Schmidt, Carolyn R; Lukasiewicz, Gloria; Truong, Therese Macasiray

    2016-02-01

    Within hospital pediatric units, there is a lack of consistent application or modeling of the American Academy of Pediatrics recommendations for safe infant sleep. The purpose of this study was to improve safe sleep practices for infants in nonneonatal pediatric units with implementation of specific interventions. This multi-institutional study was conducted by using baseline observations collected for sleep location, position, and environment (collectively, "safe sleep") of infants admitted to pediatric units. Interventions consisted of: (1) staff education, including a commitment to promote safe sleep; (2) implementing site-generated safe sleep policies; (3) designating supply storage in patient rooms; and/or (4) caregiver education. Postintervention observations of safe sleep were collected. Eight hospitals participated from the Inpatient FOCUS Group of the Children's Hospital Association. Each site received institutional review board approval/exemption. Safe sleep was observed for 4.9% of 264 infants at baseline and 31.2% of 234 infants postintervention (Ppresent in 77% of cribs at baseline and 44% postintervention. However, the mean number of unsafe items observed in each sleeping environment was reduced by >50% (P=.001). Implementation of site-specific interventions seems to improve overall safe sleep in inpatient pediatric units, although continued improvement is needed. Specifically, extra items are persistently left in the sleeping environment. Moving forward, hospitals should evaluate their compliance with American Academy of Pediatrics recommendations and embrace initiatives to improve modeling of safe sleep. Copyright © 2016 by the American Academy of Pediatrics.

  20. Quinone-induced protein handling changes: Implications for major protein handling systems in quinone-mediated toxicity

    International Nuclear Information System (INIS)

    Xiong, Rui; Siegel, David; Ross, David

    2014-01-01

    Para-quinones such as 1,4-Benzoquinone (BQ) and menadione (MD) and ortho-quinones including the oxidation products of catecholamines, are derived from xenobiotics as well as endogenous molecules. The effects of quinones on major protein handling systems in cells; the 20/26S proteasome, the ER stress response, autophagy, chaperone proteins and aggresome formation, have not been investigated in a systematic manner. Both BQ and aminochrome (AC) inhibited proteasomal activity and activated the ER stress response and autophagy in rat dopaminergic N27 cells. AC also induced aggresome formation while MD had little effect on any protein handling systems in N27 cells. The effect of NQO1 on quinone induced protein handling changes and toxicity was examined using N27 cells stably transfected with NQO1 to generate an isogenic NQO1-overexpressing line. NQO1 protected against BQ–induced apoptosis but led to a potentiation of AC- and MD-induced apoptosis. Modulation of quinone-induced apoptosis in N27 and NQO1-overexpressing cells correlated only with changes in the ER stress response and not with changes in other protein handling systems. These data suggested that NQO1 modulated the ER stress response to potentiate toxicity of AC and MD, but protected against BQ toxicity. We further demonstrated that NQO1 mediated reduction to unstable hydroquinones and subsequent redox cycling was important for the activation of the ER stress response and toxicity for both AC and MD. In summary, our data demonstrate that quinone-specific changes in protein handling are evident in N27 cells and the induction of the ER stress response is associated with quinone-mediated toxicity. - Highlights: • Unstable hydroquinones contributed to quinone-induced ER stress and toxicity

  1. Quinone-induced protein handling changes: Implications for major protein handling systems in quinone-mediated toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Rui; Siegel, David; Ross, David, E-mail: david.ross@ucdenver.edu

    2014-10-15

    Para-quinones such as 1,4-Benzoquinone (BQ) and menadione (MD) and ortho-quinones including the oxidation products of catecholamines, are derived from xenobiotics as well as endogenous molecules. The effects of quinones on major protein handling systems in cells; the 20/26S proteasome, the ER stress response, autophagy, chaperone proteins and aggresome formation, have not been investigated in a systematic manner. Both BQ and aminochrome (AC) inhibited proteasomal activity and activated the ER stress response and autophagy in rat dopaminergic N27 cells. AC also induced aggresome formation while MD had little effect on any protein handling systems in N27 cells. The effect of NQO1 on quinone induced protein handling changes and toxicity was examined using N27 cells stably transfected with NQO1 to generate an isogenic NQO1-overexpressing line. NQO1 protected against BQ–induced apoptosis but led to a potentiation of AC- and MD-induced apoptosis. Modulation of quinone-induced apoptosis in N27 and NQO1-overexpressing cells correlated only with changes in the ER stress response and not with changes in other protein handling systems. These data suggested that NQO1 modulated the ER stress response to potentiate toxicity of AC and MD, but protected against BQ toxicity. We further demonstrated that NQO1 mediated reduction to unstable hydroquinones and subsequent redox cycling was important for the activation of the ER stress response and toxicity for both AC and MD. In summary, our data demonstrate that quinone-specific changes in protein handling are evident in N27 cells and the induction of the ER stress response is associated with quinone-mediated toxicity. - Highlights: • Unstable hydroquinones contributed to quinone-induced ER stress and toxicity.

  2. Handling Kids in Crisis with Care

    Science.gov (United States)

    Bushinski, Cari

    2018-01-01

    The Handle with Care program helps schools help students who experience trauma. While at the scene of an event like a domestic violence call, drug raid, or car accident, law enforcement personnel determine the names and school of any children present. They notify that child's school to "handle ___ with care" the next day, and the school…

  3. Culturally Safe Health Initiatives for Indigenous Peoples in Canada: A Scoping Review.

    Science.gov (United States)

    Brooks-Cleator, Lauren; Phillipps, Breanna; Giles, Audrey

    2018-01-01

    Background Cultural safety has the potential to improve the health disparities between Indigenous and non-Indigenous Canadians, yet practical applications of the concept are lacking in the literature. Purpose This study aims to identify the key components of culturally safe health initiatives for the Indigenous population of Canada to refine its application in health-care settings. Methods We conducted a scoping review of the literature pertaining to culturally safe health promotion programs, initiatives, services, or care for the Indigenous population in Canada. Our initial search yielded 501 publications, but after full review of 44 publications, 30 were included in the review. After charting the data, we used thematic analysis to identify themes in the data. Results We identified six themes: collaboration/partnerships, power sharing, address the broader context of the patient's life, safe environment, organizational and individual level self-reflection, and training for health-care providers. Conclusion While it is important to recognize that the provision of culturally safe initiatives depend on the specific interaction between the health-care provider and the patient, having a common understanding of the components of cultural safety, such as those that we identified through this research, will help in the transition of cultural safety from theory into practice.

  4. Survey of tritiated oil sources and handling practices

    International Nuclear Information System (INIS)

    Miller, J.M.

    1994-08-01

    Tritium interactions with oil sources (primarily associated with pumps) in tritium-handling facilities can lead to the incorporation of tritium in the oil and the production of tritiated hydrocarbons. This results in a source of radiological hazard and the need for special handling considerations during maintenance, decontamination, decommissioning and waste packaging and storage. The results of a general survey of tritiated-oil sources and their associated characteristics, handling practices, analysis techniques and waste treatment/storage methods are summarized here. Information was obtained from various tritium-handling laboratories, fusion devices, and CANDU plants. 38 refs., 1 fig

  5. Effects of handling on fear reactions in young Icelandic horses

    DEFF Research Database (Denmark)

    Marsbøll, Anna Feldberg; Christensen, Janne Winther

    2015-01-01

    To investigate the effect of a short-term standardised handling procedure on reactions of young horses in 2 types of fear tests (including and excluding human handling). Study design An experimental study with 3-year-old Icelandic horses (n = 24). Methods Handled horses (n = 12) were trained according...... to a standardised handling procedure whereas controls (n = 12) remained untrained. Behavioural and heart rate responses in a novel object test and 2 handling fear tests (HFTs) were measured. The HFTs were conducted with both an unknown (HFT-unknown) and a known handler (HFT-known). Results There was no effect...... correlated significantly between tests. Conclusions Previous handling may affect the behavioural fear response of horses when handled by their usual handler, whereas this effect did not apply to an unknown handler. Heart rates appeared unaffected by handling and may be a more reliable indicator...

  6. Effects of Variety and Postharvest Handling Practices on Microbial Population at Different Stages of the Value Chain of Fresh Tomato (Solanum lycopersicum) in Western Terai of Nepal.

    Science.gov (United States)

    Khadka, Ram B; Marasini, Madan; Rawal, Ranjana; Gautam, Durga M; Acedo, Antonio L

    2017-01-01

    Background . Fresh vegetables such as tomato should have low microbial population for safe consumption and long storage life. The aerobic bacterial count (ABC) and coliform bacterial count (CBC), yeast, and mold population are the most widely used microbial indicators in fresh vegetables which should be lower than 4 log CFU g -1 for safe consumption. The stages of the supply chain, postharvest handling methods, and crop varieties had significant effects on microbial population. ABC, CBC, yeast, and mold population were significantly highest ( P < 0.05) at retail market (5.59, 4.38, 2.60, and 3.14 log CFU g -1 , resp.), followed by wholesale market (4.72, 4.71, 2.43, and 2.44 log CFU g -1 , resp.), and were least at farm gate (3.89, 3.63, 2.38, and 2.03 log CFU g -1 , resp.). Improved postharvest practices (washing in clean water and grading and packaging in clean plastic crate) helped to reduce ABC, CBC, and mold population by 2.51, 32.70, and 29.86 percentage as compared to the conventional method (no washing and no grading and packaging in mud plastered bamboo baskets). Among varieties, Pusa ruby had the lowest microbial load of 2.58, 4.53, 0.96, and 1.77 log CFU g -1 for ABC, CBC, yeast, and mold count, respectively. Significantly negative correlation ( P < 0.05) was observed between fruit pH & ABC and pH & mold count. Although the microbial quality of fresh tomato is safe in the local market of western Terai of Nepal both in conventional and in improved practices however still it is essential to follow improved postharvest handling practices in production and marketing of newly introduced tomato cultivars (high-pH cultivars) for ensuring the safe availability of fresh tomato in the market.

  7. American Nurses Association Nursing World

    Science.gov (United States)

    ... Standards Nursing Quality Ethics / Genetics & Genomics Code of Ethics Workplace Safety / Safe Patient Handling Needlestick Prevention Environmental Health Policy & Advocacy / Take Action Position Statements Member ...

  8. Effect of Intrafix® SafeSet infusion apparatus on phlebitis in a neurological intensive care unit: a case-control study.

    Science.gov (United States)

    Liu, F; Chen, D; Liao, Y; Diao, L; Liu, Y; Wu, M; Xue, X; You, C; Kang, Y

    2012-01-01

    To investigate the effect of the Intrafix(®) SafeSet infusion apparatus on the incidence of phlebitis in patients being intravenously infused in a neurological intensive care unit (ICU). Patients aged > 12 years, with no history of diabetes mellitus and no existing phlebitis, requiring a daily peripheral intravenous infusion of ≥ 8 h with the total period lasting ≥ 3 days, were enrolled. Infusions were performed using the Intrafix(®) SafeSet or normal infusion apparatus. Incidence of phlebitis (scored according to the Infusion Nursing Standards of Practice of the American Infusion Nurses Society) was analysed. Patients (n = 1545) were allocated to Intrafix(®) SafeSet (n = 709) or normal infusion (n = 836) groups, matched for age, gender and preliminary diagnosis. Incidence of phlebitis was significantly higher using normal infusion apparatus compared with the Intrafix(®) SafeSet (23.4% versus 17.9%, respectively). Intrafix(®) SafeSet infusion apparatus significantly reduced the incidence of phlebitis in patients in the neurological ICU, compared with normal infusion apparatus, and may be suitable for use in routine clinical practice.

  9. Safe and Effective Use of the Once Weekly Dulaglutide Single-Dose Pen in Injection-Naïve Patients With Type 2 Diabetes.

    Science.gov (United States)

    Matfin, Glenn; Van Brunt, Kate; Zimmermann, Alan G; Threlkeld, Rebecca; Ignaut, Debra A

    2015-04-21

    This 4-week, phase 3b, multicenter, open-label, single-arm, outpatient study demonstrated the safe and effective use of the dulaglutide single-dose pen containing 0.5 mL of placebo for subcutaneous injection in injection-naïve adult patients with type 2 diabetes (T2D), with A1C ≤ 8.5% (69 mmol/mol), BMI ≥ 23 kg/m2 and ≤ 45 kg/m(2). Patients completed a modified self-injecting subscale of the Diabetes Fear of Injecting and Self-Testing Questionnaire (mD-FISQ) and were trained to self-inject with the single-dose pen. Patients completed the initial self-injection at the site, injected at home for 2 subsequent weeks, and returned to the site for the final injection. The initial and final self-injections were evaluated for success; the final (initial) self-injection success rate was the primary (secondary) outcome measure, and the primary (secondary) objective was to demonstrate this success rate as being significantly greater than 80%. Patients recorded their level of pain after each injection. After the final injection, patients completed the mD-FISQ and the Medication Delivery Device Assessment Battery (MDDAB) to assess their perceptions of the single-dose pen, including ease of use and experience with the device. Among 211 patients (mean age: 61 years), the primary objective was met, with a final injection success rate of 99.1% (95% CI: 96.6% to 99.7%). Among 214 patients, the initial injection success rate was 97.2% (95% CI: 94.0% to 98.7%), meeting the key secondary objective. Overall, most patients (>96%) found the device easy to use, were satisfied with the device, and would be willing to continue to use the single-dose pen after the study. There was a significant reduction (P injecting, as measured by the mD-FISQ. The dulaglutide single-dose pen was found to be a safe and effective device for use by patients with T2D who were injection-naïve. A positive injection experience is an important factor for patients and providers when initiating injectable

  10. FEMA and RAM Analysis for the Multi Canister Overpack (MCO) Handling Machine

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    The Failure Modes and Effects Analysis and the Reliability, Availability, and Maintainability Analysis performed for the Multi-Canister Overpack Handling Machine (MHM) has shown that the current design provides for a safe system, but the reliability of the system (primarily due to the complexity of the interlocks and permissive controls) is relatively low. No specific failure modes were identified where significant consequences to the public occurred, or where significant impact to nearby workers should be expected. The overall reliability calculation for the MHM shows a 98.1 percent probability of operating for eight hours without failure, and an availability of the MHM of 90 percent. The majority of the reliability issues are found in the interlocks and controls. The availability of appropriate spare parts and maintenance personnel, coupled with well written operating procedures, will play a more important role in successful mission completion for the MHM than other less complicated systems

  11. Handling wood shavings

    Energy Technology Data Exchange (ETDEWEB)

    1974-09-18

    Details of bulk handling equipment suitable for collection and compressing wood waste from commercial joinery works are discussed. The Redler Bin Discharger ensures free flow of chips from storage silo discharge prior to compression into briquettes for use as fuel or processing into chipboard.

  12. [How to handle the dilemma of driving for patients with Alzheimer's disease? A survey of advices provided by French caregivers guides].

    Science.gov (United States)

    Mietkiewicz, Marie-Claude; Ostrowski, Madeleine

    2015-09-01

    For many old people, driving takes an important place in the daily living activities and contributes to carry on their autonomy and self-esteem. However, many studies showed a link between car accidents and Alzheimer's disease, even in the early stages of dementia, and people caring for these patients inevitably ask the question: "Is my patient with Alzheimer's disease still able to drive his car?" Guides devoted to caregivers can play an important role to improve the knowledge of Alzheimer's disease and to afford advices for patients managing. To assess how these guides handle the question of patients driving, we made a survey of the 46 French caregiver guides (re)published between 1988 and 2013. The question of driving is raised with more or less details in 31 guides. All state that driving should be discontinued but that the consequences of this decision on the patient autonomy should be taken into account. A few guides provide clues to assess driving competence for the patients, and many propose advices to support the implementation of the driving discontinuity decision, such as to discuss with the patient to persuade him to stop driving, to ask for assistance by the family physician, to hide the car's keys or to disconnect its battery... In France, physicians are not allowed to prohibit driving or to report dangerous driving to authorities. Ultimately, the caregivers remain faced with the ethical dilemma to choose between safety and the patient's autonomy preservation. Therefore the responsibility for the patient to persist or give up driving only falls to them.

  13. Handling of bulk solids theory and practice

    CERN Document Server

    Shamlou, P A

    1990-01-01

    Handling of Bulk Solids provides a comprehensive discussion of the field of solids flow and handling in the process industries. Presentation of the subject follows classical lines of separate discussions for each topic, so each chapter is self-contained and can be read on its own. Topics discussed include bulk solids flow and handling properties; pressure profiles in bulk solids storage vessels; the design of storage silos for reliable discharge of bulk materials; gravity flow of particulate materials from storage vessels; pneumatic transportation of bulk solids; and the hazards of solid-mater

  14. Only MR can safely exclude patients from arthroscopy

    International Nuclear Information System (INIS)

    Vincken, Patrice W.J.; Braak, Bert P.M. ter; Erkel, Arian R. van; Bloem, Johan L.; Bloem, Rolf M.; Luijt, Peter A. van; Coene, L.N.J.E.M.; Lange, Sam de

    2009-01-01

    The aim of this study was to determine in patients with subacute knee complaints and normal standardized physical examination the fraction of magnetic resonance imaging (MRI) studies showing arthroscopically treatable intra-articular pathology. There were 290 consecutive patients (between 16 and 45 years) with at least 4 weeks of knee complaints and low clinical suspicion of intra-articular pathology based on physical exam. Two hundred seventy-four patients were included. Sixteen patients with prior knee surgery, rheumatic arthritis, or severe osteoarthritis were excluded. MRI was used to assign patients to group 1 (treatable abnormalities) or group 2 (normal or no treatable findings), depending on whether MR demonstrated treatable pathology. Arthroscopy was performed in group 1 patients. If symptoms persisted for 3 months in group 2 patients, cross over to arthroscopy was allowed. MR showed treatable pathology in 73 patients (26.6%). Arthroscopy was performed in 64 patients of 73 patients (group 1). In 52 patients (81.3%, 95% confidence interval (CI) 71.4-91.1%), arthroscopy was therapeutic. Of the 13 arthroscopies (6.5%) in group 2, four were therapeutic (30.8%, 95% CI 1.7-59.8). The highest fraction of MR studies showing treatable pathology was found in males, aged over 30 years, with a history of effusion (54.5%, six of 11 patients). Authors believe that the negative predictive value of clinical assessment in patients with subacute knee complaints is too low to exclude these patients from MR. MR should at least be considered in male patients aged 30 years and over with a history of effusion. (orig.)

  15. Only MR can safely exclude patients from arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vincken, Patrice W.J.; Braak, Bert P.M. ter; Erkel, Arian R. van; Bloem, Johan L. [Leiden University Medical Center, Department of Radiology, P.O. Box 9600, Leiden (Netherlands); Bloem, Rolf M. [Leiden University Medical Center, Department of Orthopedic Surgery, Leiden (Netherlands); Reinier de Graaf Gasthuis, Department of Orthopedic Surgery, Delft (Netherlands); Luijt, Peter A. van [Leiden University Medical Center, Department of Traumatology, Leiden (Netherlands); Coene, L.N.J.E.M. [HAGA Hospital, Department of Orthopaedic Surgery, The Hague (Netherlands); Lange, Sam de [Medical Center Haaglanden, Department of Orthopedic Surgery, The Hague (Netherlands)

    2009-10-15

    The aim of this study was to determine in patients with subacute knee complaints and normal standardized physical examination the fraction of magnetic resonance imaging (MRI) studies showing arthroscopically treatable intra-articular pathology. There were 290 consecutive patients (between 16 and 45 years) with at least 4 weeks of knee complaints and low clinical suspicion of intra-articular pathology based on physical exam. Two hundred seventy-four patients were included. Sixteen patients with prior knee surgery, rheumatic arthritis, or severe osteoarthritis were excluded. MRI was used to assign patients to group 1 (treatable abnormalities) or group 2 (normal or no treatable findings), depending on whether MR demonstrated treatable pathology. Arthroscopy was performed in group 1 patients. If symptoms persisted for 3 months in group 2 patients, cross over to arthroscopy was allowed. MR showed treatable pathology in 73 patients (26.6%). Arthroscopy was performed in 64 patients of 73 patients (group 1). In 52 patients (81.3%, 95% confidence interval (CI) 71.4-91.1%), arthroscopy was therapeutic. Of the 13 arthroscopies (6.5%) in group 2, four were therapeutic (30.8%, 95% CI 1.7-59.8). The highest fraction of MR studies showing treatable pathology was found in males, aged over 30 years, with a history of effusion (54.5%, six of 11 patients). Authors believe that the negative predictive value of clinical assessment in patients with subacute knee complaints is too low to exclude these patients from MR. MR should at least be considered in male patients aged 30 years and over with a history of effusion. (orig.)

  16. Hazard Control Extensions in a COTS Based Data Handling System

    Science.gov (United States)

    Vogel, Torsten; Rakers, Sven; Gronowski, Matthias; Schneegans, Joachim

    2011-08-01

    EML is an electromagnetic levitator for containerless processing of conductive samples on the International Space Station. This material sciences experiment is running in the European Drawer Rack (EDR) facility. The objective of this experiment is to gain insight into the parameters of liquid metal samples and their crystallisation processes without the influence of container walls. To this end the samples are electromagnetically positioned in a coil system and then heated up beyond their melting point in an ultraclean environment.The EML programme is currently under development by Astrium Space Transportation in Friedrichshafen and Bremen; jointly funded by ESA and DLR (on behalf of BMWi, contract 50WP0808). EML consists of four main modules listed in Table 1. The paper focuses mainly on the architecture and design of the ECM module and its contribution to a safe operation of the experiment. The ECM is a computer system that integrates the power supply to the EML experiment, control functions and video handling and compression features. Experiment control is performed by either telecommand or the execution of predefined experiment scripts.

  17. Getting to grips with remote handling and robotics

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, D [Ontario Hydro, Toronto (Canada)

    1984-12-01

    A report on the Canadian Nuclear Society Conference on robotics and remote handling in the nuclear industry, September 1984. Remote handling in reactor operations, particularly in the Candu reactors is discussed, and the costs and benefits of use of remote handling equipment are considered. Steam generator inspection and repair is an area in which practical application of robotic technology has made a major advance.

  18. Redefining NHS complaint handling--the real challenge.

    Science.gov (United States)

    Seelos, L; Adamson, C

    1994-01-01

    More and more organizations find that a constructive and open dialogue with their customers can be an effective strategy for building long-term customer relations. In this context, it has been recognized that effective complaint-contact handling can make a significant contribution to organizations' attempts to maximize customer satisfaction and loyalty. Within the NHS, an intellectual awareness exists that effective complaint/contact handling can contribute to making services more efficient and cost-effective by developing customer-oriented improvement initiatives. Recent efforts have focused on redefining NHS complaint-handling procedures to make them more user-friendly and effective for both NHS employees and customers. Discusses the challenges associated with opening up the NHS to customer feedback. Highlights potential weaknesses in the current approach and argues that the real challenge is for NHS managers to facilitate a culture change that moves the NHS away from a long-established defensive complaint handling practice.

  19. Bucket handle tears of the medial meniscus: meniscal intrusion rather than meniscal extrusion

    International Nuclear Information System (INIS)

    Schlossberg, S.; Umans, H.; Flusser, G.; DiFelice, G.S.; Lerer, D.B.

    2007-01-01

    To determine the frequency of medial meniscal extrusion (MME) versus ''medial meniscal intrusion'' in the setting of bucket handle tears. Images were evaluated for previously reported risk factors for MME, including: medial meniscal root tear, radial tear, degenerative joint disease and joint effusion. Forty-one consecutive cases of bucket handle tear of the medial meniscus were reviewed by consensus by two musculoskeletal radiologists. Imaging was performed using a 1.5 GE Signa MR unit. Patient age, gender, medial meniscal root integrity, MME, medial meniscal intrusion, degenerative joint disease, effusion and anterior cruciate ligament (ACL) tear were recorded. Thirteen females and 27 males (age 12-62 years, median=30 years) were affected; one had bucket handle tear of each knee. Effusion was small in 13, moderate in 9 and large in 18. Degenerative joint disease was mild in three, moderate in two and severe in one. 26 ACL tears included three partial and three chronic. Medial meniscal root tear was complete in one case and partial thickness in two. None of the 40 cases with an intact or partially torn medial meniscal root demonstrated MME. MME of 3.1 mm was seen in the only full-thickness medial meniscal root tear, along with chronic ACL tear, moderate degenerative joint disease and large effusion. Medial meniscal intrusion of the central bucket handle fragment into the intercondylar notch was present in all 41 cases. Given an intact medial meniscal root in the setting of a ''pure'' bucket handle tear, there is no MME. (orig.)

  20. MHSS: a material handling system simulator

    Energy Technology Data Exchange (ETDEWEB)

    Pomernacki, L.; Hollstien, R.B.

    1976-04-07

    A Material Handling System Simulator (MHSS) program is described that provides specialized functional blocks for modeling and simulation of nuclear material handling systems. Models of nuclear fuel fabrication plants may be built using functional blocks that simulate material receiving, storage, transport, inventory, processing, and shipping operations as well as the control and reporting tasks of operators or on-line computers. Blocks are also provided that allow the user to observe and gather statistical information on the dynamic behavior of simulated plants over single or replicated runs. Although it is currently being developed for the nuclear materials handling application, MHSS can be adapted to other industries in which material accountability is important. In this paper, emphasis is on the simulation methodology of the MHSS program with application to the nuclear material safeguards problem. (auth)