WorldWideScience

Sample records for sa 106-b piping

  1. Leak before break evaluation for main steam piping system made of SA106 Gr.C

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kyoung Mo; Jee, Kye Kwang; Pyo, Chang Ryul; Ra, In Sik [Korea Power Engineering Company, Seoul (Korea, Republic of)

    1997-04-01

    The basis of the leak before break (LBB) concept is to demonstrate that piping will leak significantly before a double ended guillotine break (DEGB) occurs. This is demonstrated by quantifying and evaluating the leak process and prescribing safe shutdown of the plant on the basis of the monitored leak rate. The application of LBB for power plant design has reduced plant cost while improving plant integrity. Several evaluations employing LBB analysis on system piping based on DEGB design have been completed. However, the application of LBB on main steam (MS) piping, which is LBB applicable piping, has not been performed due to several uncertainties associated with occurrence of steam hammer and dynamic strain aging (DSA). The objective of this paper is to demonstrate the applicability of the LBB design concept to main steam lines manufactured with SA106 Gr.C carbon steel. Based on the material properties, including fracture toughness and tensile properties obtained from the comprehensive material tests for base and weld metals, a parametric study was performed as described in this paper. The PICEP code was used to determine leak size crack (LSC) and the FLET code was used to perform the stability assessment of MS piping. The effects of material properties obtained from tests were evaluated to determine the LBB applicability for the MS piping. It can be shown from this parametric study that the MS piping has a high possibility of design using LBB analysis.

  2. An electrochemical study of the flow rate effect on the oxide film of SA106 Gr.C piping

    International Nuclear Information System (INIS)

    Hong, S. M.; Kim, J. H.; Kim, I. S.

    2002-01-01

    Effect of water flow rate on the oxide film of SA106 Gr.C piping was evaluated quantitatively through electrochemical method. It was carried out with weight change experiments, polarization tests, and EIS tests with rig that simulates water flow. Without water flow, the oxide film is so stable that it effectively blocks current exchange. With water flow, the oxide film was damaged and electrochemical current density and oxide film properties, C dl and R p were significantly changed

  3. Evaluation of the plastic characteristics of piping products in relation to ASME code criteria

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1978-07-01

    Theories and test data relevant to the plastic characteristics of piping products are presented and compared with Code Equations in NB-3652 for Class 1 piping; in NC/ND-3652.2 for Class 2 and Class 3 piping. Comparisons are made for (a) straight pipe, (b) elbows, (c) branch connections, and (d) tees. The status of data (or lack of data) for other piping components is discussed. Comparisons are made between available data and the Code equations for two typical piping materials, SA106 Grade B and SA312 TP304, for Code Design Limits, and Service Limits A, B, C, and D. Conditions under which the Code Limits cannot be shown to be conservative from available data are pointed out. Based on the results of the study, recommendations for Code revisions are presented, along with recommendations for additional work

  4. Construction of continuous cooling transformation (CCT) diagram using Gleeble for coarse grained heat affected zone of SA106 grade B steel

    Science.gov (United States)

    Vimalan, G.; Muthupandi, V.; Ravichandran, G.

    2018-05-01

    A continuous cooling transformation diagram is constructed for simulated coarse grain heat affected zone (CGHAZ) of SA106 grade B carbon steel. Samples are heated to a peak temperature of 1200°C in the Gleeble thermo mechanical simulator and then cooled at different cooling rates varying from 0.1°C/s to 100°C/s. Microstructure of the specimens simulated at different cooling rates were characterised by optical microscopy and hardness was assessed by Vicker's hardness test and micro-hardness test. Transformation temperatures and the corresponding phase fields were identified from dilatometric curves and the same could be confirmed by correlating with the microstructures at room temperature. These data were used to construct the CCT diagram. Phase fields were found to have ferrite, pearlite, bainite and martensite or their combinations. With the help of this CCT diagram it is possible to predict the microstructure and hardness of coarse grain HAZ experiencing different cooling rates. The constructed CCT diagram becomes an important tool in evaluating the weldability of SA106 grade B carbon steel.

  5. Microbiologically influenced corrosion of sa106 gr.b carbon steel in raw water

    International Nuclear Information System (INIS)

    Tunaru, M.; Velciu, L.; Stancu, M.; Popa, L.

    2015-01-01

    This paper presents the evaluation of microbiological corrosion susceptibility of carbon steel SA106gr.B in raw water. The experiment consisted of a series of electrochemical accelerated tests which evaluated the pitting corrosion susceptibility and determined corrosion rates before and after the immersion. The microbiological analysis of the water determined the types of bacteria and bacterial concentration present in water and in biofilms. Microbiological analysis of the water sample emphasized the existence, in small numbers (10-101 ml-1), of heterotrophic aerobic bacteria, sulphate-reducing bacteria and iron-oxidizing microorganisms. Along with sulphate-reducing bacteria, the heterotrophic aerobic bacteria and the iron-oxidizing microorganisms are categorized as having an important role in the corrosion of metals, including steel. The surfaces of the tested samples were analysed using the optical and electronic microscope, and emphasized the role of bacteria in the development of biofilms under which appeared characteristics of corrosion attack. (authors)

  6. Assessment of the sulfide corrosion fatigue strength for a multi-pass welded A106 Gr B steel pipe below the low SSCC limit

    International Nuclear Information System (INIS)

    Lee, Gyu Young; Bae, Dong Ho

    2009-01-01

    In the area of heavy construction, welding processes are vital in the production and maintenance of pipelines and power plants. Welding processes happen to produce residual stresses and change the metal structure as a result of the large nonlinear thermal loading that is created by a moving heat source. The fusion welding process generates formidable welding residual stresses and metallurgical change, which increase the crack driving force and reduce the resistance to the brittle fracture as well as the environmental fracture. This is a serious problem with many alloys as well as the A106 Gr B steel pipe. This pipe that is used in petrochemical and heavy chemical plants either degrades due to corrosive environments, e.g., chlorides and sulfides, and/or become damaged during service due to the various corrosion damage mechanisms. Thus, in this study, after numerically and experimentally analyzing the welding residual stress of a multi-pass welded A106 Gr B steel pipe, the sulfide stress corrosion cracking (SSCC) characteristics were assessed in a 3.5 wt.% NaCl solution that was saturated with H 2 S gas at room temperature on the basis of NACE TM 0177-90. The specimens used are of two kinds: un-notched and notched. Then, the sulfide corrosion fatigue (SCF) strength for the un-notched specimen was assessed below the low SSCC limit that was previously obtained from the SSCC tests for the notched specimen. From the results, in terms of the SSCC and SCF, all the specimens failed at the heat-affected zone, where a high welding residual stress is distributed. It was found that the low SSCC limit of un-notched specimens (σSSCCun-notched) was 46% (230 MPa) of the ultimate tensile strength (σU=502 MPa) of a multi-pass welded A106 Gr B steel pipe, and the notched specimens (σSSCCnotched) had 40% (200 MPa) of the ultimate tensile strength. Thus, it was determined that σSSCCun-notched was 13% lower than σSSCCnotched. Further, the sulfide corrosion fatigue limit (

  7. Use of Neuber's rule to estimate the fatigue life of notched specimens of ASME SA 106-B steel piping in 2880C air

    International Nuclear Information System (INIS)

    Terrell, J.B.

    1989-01-01

    Fatigue strain-life tests were conducted on notched specimens of ADMESA 106-B piping steel at PWR operating temperatures (288 0 C (550 0 F)), under completely reversed loading. Fatigue limits at 10 7 cycles were estimated for smooth specimens to be 185 M Pa (26.8 ksi) at 24 0 C and 232 MPa (33.7 ksi) at 288 0 C. The higher fatigue strength observed at the PWR temperature is postulated to be caused by dynamic strain aging processes. However, a reduction in fatigue strength in the low cycle fatigue regime was observed in 288 0 C air environment tests, which may indicate that the current ASME Section III design curve for carbon steels is nonconservative in its positioning. Notch strain histories were estimated for the notched specimen tests using various interpretations of Neuber's rule. It was concluded that the use of the fatigue notch concentration factor (K f ) in the Neuber relation in conjunction with the uniaxial cyclic stress-strain curve provided the best correlation of notched specimen fatigue data with results obtained from smooth specimen tests. The notched specimen strain-life results derived from the application of Neuber's rule alone proved to be conservative when compared with smooth specimen test results to such an extent that Neuber-generated notch stresses and strain amplitudes cannot accurately be compared with the mean data curves derived from the ASME Section III fatigue curves for carbon steels which are based on net section stress measurements. (author)

  8. Qualification of diesel generator exhaust carbon steel piping to intermitted elevated temperatures

    International Nuclear Information System (INIS)

    Ratiu, M.D.; Moisidis, N.T.

    1996-01-01

    The diesel generator exhaust piping, usually made up of carbon steel piping (e.g., ASME SA-106, SA-53), is subjected to successive short time exposures at elevated temperatures up to 1,000 F (538 C). A typical design of this piping, without consideration for creep-fatigue cumulative damage, is at least incomplete, if not inappropriate. Also, a design for creep-fatigue, usually employed for long-term exposure to elevated temperatures, would be too conservative and will impose replacement of the carbon steel piping with heat-resistant CrMo alloy piping. The existing ASME standard procedures do not explicitly provide acceptance criteria for the design qualification to withstand these intermittent exposures to elevated temperatures. The serviceability qualification proposed is based on the evaluation of equivalent full temperature cycles which are presumed/expected to be experienced by the exhaust piping during the design operating life of the diesel engine. The proposed serviceability analysis consists of: (a) determination of the permissible stress at elevated temperatures, and (b) estimation of creep-fatigue damage for the total expected cycles of elevated temperature exposures following the procedure provided in ASME Code Cases N-253-6 and N-47-28

  9. A serviceability approach for carbon steel piping to intermittent high temperatures

    International Nuclear Information System (INIS)

    Ratiu, M.D.; Moisidis, N.T.

    1996-01-01

    Carbon steel piping (e.g., ASME SA-106, SA-53), is installed in many industrial applications (i.e. diesel generator at NPP) where the internal gas flow subjects the piping to successive short time exposures at elevated temperatures up to 1,100 F. A typical design of this piping without consideration for creep-fatigue cumulative damage is at least incomplete if not inappropriate. Also, a design for creep-fatigue, usually employed for long-term exposure to elevated temperatures, would be too conservative and will impose replacement of the carbon steel piping with heat-resistant CrMo steel piping. The existing ASME Standard procedures do not explicitly provide acceptance criteria for the design qualification to withstand these intermittent exposures to elevated temperatures. The serviceability qualification proposed is based on the evaluation of equivalent full temperature cycles which are presumed/expected to be experienced by the exhaust piping during the design operating life of the diesel engine. The proposed serviceability analysis consists of: (a) determination of the permissible stress at elevated temperatures, and (b) estimation of creep-fatigue damage for the total expected cycles of elevated temperature exposures following the procedure provided in ASME Code Cases N-253-6 and N-47-28

  10. Fatigue life response of ASME SA 106-B steel in pressurized water reactor environments

    International Nuclear Information System (INIS)

    Terrell, J.B.

    1989-01-01

    Fatigue strain-life tests were conducted on ASMESA 106-B piping steel base metal and weld metal specimens in 288 0 C (550 0 F) pressurized water reactor (PWR) environments as a function of strain amplitude, strain ratio, notch acuity, and cyclic frequency. Notched base metal specimens tested at 0.017 Hz in 0.001 part per million (ppm) dissolved oxygen environments nearly completely used up the margins of safety of 2 on stress and 20 on cycles incorporated into the ASMA Section III design curve for carbon steels. Tests conducted with smooth base metal and weld metal specimens at 1.0 Hz showed virtually no degradation in cycles to failure when compared to 288 0 C air test results. In all cases, however, the effect of temperature alone reduced the margin of safety offered by the design curve in the low cycle regime for the test specimens. Comparison between the fatigue life results of smooth and notched specimens suggests that fatigue crack initiation is not significantly affected by 0.001 ppm dissolved oxygen, and that most of the observed degradation may be attributed to crack growth acceleration. These results suggest that the ASMA Section III methodology should be reviewed, taking into account the PWR environment variables which degrade the fatigue life of pressure-retaining components. (author)

  11. Fatigue life response of ASME SA 106-B steel in pressurized water reactor environments

    Energy Technology Data Exchange (ETDEWEB)

    Terrell, J B [Materials Engineering Associates, Inc., Lanham, MD (USA)

    1989-01-01

    Fatigue strain-life tests were conducted on ASMESA 106-B piping steel base metal and weld metal specimens in 288{sup 0}C (550{sup 0}F) pressurized water reactor (PWR) environments as a function of strain amplitude, strain ratio, notch acuity, and cyclic frequency. Notched base metal specimens tested at 0.017 Hz in 0.001 part per million (ppm) dissolved oxygen environments nearly completely used up the margins of safety of 2 on stress and 20 on cycles incorporated into the ASMA Section III design curve for carbon steels. Tests conducted with smooth base metal and weld metal specimens at 1.0 Hz showed virtually no degradation in cycles to failure when compared to 288{sup 0}C air test results. In all cases, however, the effect of temperature alone reduced the margin of safety offered by the design curve in the low cycle regime for the test specimens. Comparison between the fatigue life results of smooth and notched specimens suggests that fatigue crack initiation is not significantly affected by 0.001 ppm dissolved oxygen, and that most of the observed degradation may be attributed to crack growth acceleration. These results suggest that the ASMA Section III methodology should be reviewed, taking into account the PWR environment variables which degrade the fatigue life of pressure-retaining components. (author).

  12. Development of remote pipe welding tool for divertor cassettes in JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takao, E-mail: hayashi.takao@jaea.go.jp [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Naka (Japan); Sakurai, Shinji; Sakasai, Akira; Shibanuma, Kiyoshi [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Naka (Japan); Kono, Wataru; Ohnawa, Toshio; Matsukage, Takeshi [Toshiba Corporation, Yokohama, Kanagawa (Japan)

    2015-12-15

    Highlights: • Remote pipe welding tool accessing from inside of the pipe has been newly developed. • Cooling pipe with a jut on the edge expands the acceptable welding gap up to 0.5 mm. • Positioning accuracy of the laser beam is realized to be less than ±0.1 mm. • We have achieved robust welding for an angular misalignment of 0.5°. - Abstract: Remote pipe welding tool accessing from inside of the pipe has been newly developed for JT-60SA. Remote handling (RH) system is necessary for the maintenance and repair of the divertor cassette in JT-60SA. Because the space around the cooling pipe connected with the divertor cassette is very limited, the cooling pipe is to be remotely cut and welded from inside for the maintenance. A laser welding method was employed to perform circumferential welding by rotating the focusing mirror inside the pipe. However, the grooves of connection pipes are not precisely aligned for welding. The most critical issue is therefore to develop a reliable welding tool for pipe connection without a defect such as undercut weld due to a gap caused by angular and axial misalignments of grooves. In addition, an angular misalignment between two pipes due to inclination of pipe has to be taken into account for the positioning of the laser beam during welding. In this paper, the followings are proposed to solve the above issues: (1) Cooling pipe connected with the divertor is machined to have a jut on the edge so as to expand the acceptable welding gap up to 0.5 mm by filling the gap with welded jut. (2) Positioning accuracy of the laser beam for reliable welding is realized to be less than ±0.1 mm along the circumferential target for welding by a position control mechanism provided in the tool even in the case of up to angular misalignment of 0.5° between connection pipes. Based on the above proposals, we have achieved robust welding for a large gap up to 0.5 mm as well as the maximum angular misalignment of 0.5° between connection pipes

  13. Study on corrosion resistance of A106Gr.B and A672Gr.B60 in dynamic water loop with high temperature and pressure

    International Nuclear Information System (INIS)

    Tian Jue; Wang Hui; Li Xinmin

    2014-01-01

    Due to the low carbon and low alloy Cr content, flow accelerates corrosion prone to have a serious impact on safety. AP1000 is the most advanced nuclear power technology in recent years. The plant used A672Gr.B60 as an alternative feed pipe to reduce the impact of flow accelerated corrosion. The impact of different flow rates, alkaline agent type and material property on A672Gr.B60 and A106Gr.B were characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectronic spectroscopy (XPS). After 336 h experiments were conducted, results show that the corrosion rate of A672Gr.B60 is much lower than that of A106Gr.B, and the density of oxidation film on A672Gr.B60 is superior to A106Gr.B. Ethanolamine (ETA) as an alkaline agent is better to reduce FAC to A106Gr.B, and it also can make the oxidation film become denser. Changes in flow rate will affect the size, shape and distribution of the oxide particles, and will also affect the thickness of the oxide film. Both of two materials were composed by Fe 3 O 4 . (authors)

  14. Development of remote pipe cutting tool for divertor cassettes in JT-60SA

    International Nuclear Information System (INIS)

    Hayashi, Takao; Sakurai, Shinji; Shibanuma, Kiyoshi; Sakasai, Akira

    2014-01-01

    Remote pipe cutting tool accessing from inside pipe has been newly developed for JT-60SA. The tool head equips a disk-shaped cutter blade and four rollers which are subjected to the reaction force. The tool pushes out the cutter blade by decreasing the distance between two cams. The tool cuts a cooling pipe by both pushing out the cutter blade and rotating the tool head itself. The roller holder is not pushed out anymore after touching the inner wall of the pipe. In other words, only cutter blade is pushed out after bringing the tool axis into the pipe axis. Outer diameter of the cutting tool head is 44 mm. The cutting tool is able to push out the cutter blade up to 32.5 mm in radius, i.e. 65 mm in diameter, which is enough to cut the pipe having an outer diameter of 59.8 mm. The thickness and material of the cooling pipe are 2.8 mm and SUS316L, respectively. The length of the cutting tool head is about 1 m. The tool is able to cut a pipe locates about 480 mm in depth from the mounting surface on the divertor cassette. The pipe cutting system equips two cutting heads and they are able to cut two pipes at the same time in order to remove the inner target plate. Reproducibility of the cross-sectional shape of the cut pipe is required for re-welding. The degree of reproducibility is inside 0.1 mm except for burr at outside of the pipe, which is enough to re-weld the cut pipe. Some swarf is generated during cutting the double-layered pipe assuming a plug located on the top of the pipe. The swarf is deposited on the bottom of the plug and collected by pulling out the plug in the actual equipment

  15. A Study on Effect of Local Wall Thinning in Carbon Steel Elbow Pipe on Elastic Stress Concentration

    International Nuclear Information System (INIS)

    Kim, Jong Sung; Seo, Jae Seok

    2009-01-01

    Feeder pipes that connect the inlet and outlet headers to the reactor core in CANDU nuclear power plants are considered as safety Class 1 piping items. Therefore, fatigue of feeder pipes should be assessed at design stage in order to verify structural integrity during design lifetime. In accordance with the fatigue assessment result, cumulative usage factors of some feeder pipes have significant values. The feeder pipes made of SA-106 Grade B or C carbon steel have some elbows and bends. An active degradation mechanism for the carbon steel outlet feeder piping is local wall thinning due to flow-accelerated corrosion. Inspection results from plants and metallurgical examinations of removed feeders indicated the presence of localized thinning in the vicinity of the welds in the lower portion of outlet feeders, such as Grayloc hub-to-bend weld, Grayloc hub-to-elbow weld, elbow-to-elbow, and elbow-to-pipe weld. This local wall thinning can cause increase of peak stress due to stress concentration by notch effect. The increase of peak stress results in increase of cumulative usage factor. However, present fatigue assessment doesn't consider the stress concentration due to local wall-thinning. Therefore, it is necessary to assess the effect of local wall thinning on stress concentration. This study investigates the effect of local wall thinning geometry on stress concentration by performing finite element elastic stress analysis

  16. BRD4 regulates cellular senescence in gastric cancer cells via E2F/miR-106b/p21 axis.

    Science.gov (United States)

    Dong, Xingchen; Hu, Xiangming; Chen, Jinjing; Hu, Dan; Chen, Lin-Feng

    2018-02-12

    Small molecules targeting bromodomains of BET proteins possess strong anti-tumor activities and have emerged as potential therapeutics for cancer. However, the underlying mechanisms for the anti-proliferative activity of these inhibitors are still not fully characterized. In this study, we demonstrated that BET inhibitor JQ1 suppressed the proliferation and invasiveness of gastric cancer cells by inducing cellular senescence. Depletion of BRD4, which was overexpressed in gastric cancer tissues, but not other BET proteins recapitulated JQ1-induced cellular senescence with increased cellular SA-β-Gal activity and elevated p21 levels. In addition, we showed that the levels of p21 were regulated at the post-transcriptional level by BRD4-dependent expression of miR-106b-5p, which targets the 3'-UTR of p21 mRNA. Overexpression of miR-106b-5p prevented JQ1-induced p21 expression and BRD4 inhibition-associated cellular senescence, whereas miR-106b-5p inhibitor up-regulated p21 and induced cellular senescence. Finally, we demonstrated that inhibition of E2F suppressed the binding of BRD4 to the promoter of miR-106b-5p and inhibited its transcription, leading to the increased p21 levels and cellular senescence in gastric cancer cells. Our results reveal a novel mechanism by which BRD4 regulates cancer cell proliferation by modulating the cellular senescence through E2F/miR-106b-5p/p21 axis and provide new insights into using BET inhibitors as potential anticancer drugs.

  17. Partial Tmem106b reduction does not correct abnormalities due to progranulin haploinsufficiency.

    Science.gov (United States)

    Arrant, Andrew E; Nicholson, Alexandra M; Zhou, Xiaolai; Rademakers, Rosa; Roberson, Erik D

    2018-06-22

    Loss of function mutations in progranulin (GRN) are a major cause of frontotemporal dementia (FTD). Progranulin is a secreted glycoprotein that localizes to lysosomes and is critical for proper lysosomal function. Heterozygous GRN mutation carriers develop FTD with TDP-43 pathology and exhibit signs of lysosomal dysfunction in the brain, with increased levels of lysosomal proteins and lipofuscin accumulation. Homozygous GRN mutation carriers develop neuronal ceroid lipofuscinosis (NCL), an earlier-onset lysosomal storage disorder caused by severe lysosomal dysfunction. Multiple genome-wide association studies have shown that risk of FTD in GRN mutation carriers is modified by polymorphisms in TMEM106B, which encodes a lysosomal membrane protein. Risk alleles of TMEM106B may increase TMEM106B levels through a variety of mechanisms. Brains from FTD patients with GRN mutations exhibit increased TMEM106B expression, and protective TMEM106B polymorphisms are associated with decreased TMEM106B expression. Together, these data raise the possibility that reduction of TMEM106B levels may protect against the pathogenic effects of progranulin haploinsufficiency. We crossed Tmem106b +/- mice with Grn +/- mice, which model the progranulin haploinsufficiency of GRN mutation carriers and develop age-dependent social deficits and lysosomal abnormalities in the brain. We tested whether partial Tmem106b reduction could normalize the social deficits and lysosomal abnormalities of Grn +/- mice. Partial reduction of Tmem106b levels did not correct the social deficits of Grn +/- mice. Tmem106b reduction also failed to normalize most lysosomal abnormalities of Grn +/- mice, except for β-glucuronidase activity, which was suppressed by Tmem106b reduction and increased by progranulin insufficiency. These data do not support the hypothesis that Tmem106b reduction protects against the pathogenic effects of progranulin haploinsufficiency, but do show that Tmem106b reduction normalizes some

  18. 14 CFR 1203b.106 - Use of deadly force.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Use of deadly force. 1203b.106 Section... AUTHORITY AND USE OF FORCE BY NASA SECURITY FORCE PERSONNEL § 1203b.106 Use of deadly force. Deadly force shall be used only in those circumstances where the security force officer reasonably believes that...

  19. 76 FR 47555 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-08-05

    ... Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  20. Effect of Cr content on the FAC of pipe material at 150 .deg. C

    International Nuclear Information System (INIS)

    Park, Tae Jun; Kim, Hong Pyo

    2013-01-01

    Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. During the FAC, a protective oxide layer on carbon steel dissolves into flowing water leading to a thinning of the oxide layer and accelerating corrosion of base material. As a result, severe failures may occur in the piping and equipment of NPPs. Effect of alloying elements on FAC of pipe materials was studied with rotating cylinder FAC test facility at 150 .deg. C and at flow velocity of 4m/s. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO) and temperature. Test solution was the demineralized water, and DO concentration was less than 1 ppb. Surface appearance of A 106 Gr. B which is used widely in secondary pipe in NPPs showed orange peel appearance, typical appearance of FAC. The materials with Cr content higher than 0.17wt.% showed pit. The pit is thought to early degradation mode of FAC. The corrosion product within the pit was enriched with Cr, Mo, Cu, Ni and S. But S was not detected in SA336 F22V with 2.25wt.% Cr. The enrichment of Cr and Mo seemed to be related with low, solubility of Cr and Mo compared to Fe. Measured FAC rate was compared with Ducreaux's relationship and showed slightly lower FAC rate than Ducreaux's relationship

  1. 77 FR 27428 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-05-10

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  2. 76 FR 66688 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-10-27

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  3. The FTLD risk factor TMEM106B and MAP6 control dendritic trafficking of lysosomes

    Science.gov (United States)

    Schwenk, Benjamin M; Lang, Christina M; Hogl, Sebastian; Tahirovic, Sabina; Orozco, Denise; Rentzsch, Kristin; Lichtenthaler, Stefan F; Hoogenraad, Casper C; Capell, Anja; Haass, Christian; Edbauer, Dieter

    2014-01-01

    TMEM106B is a major risk factor for frontotemporal lobar degeneration with TDP-43 pathology. TMEM106B localizes to lysosomes, but its function remains unclear. We show that TMEM106B knockdown in primary neurons affects lysosomal trafficking and blunts dendritic arborization. We identify microtubule-associated protein 6 (MAP6) as novel interacting protein for TMEM106B. MAP6 over-expression inhibits dendritic branching similar to TMEM106B knockdown. MAP6 knockdown fully rescues the dendritic phenotype of TMEM106B knockdown, supporting a functional interaction between TMEM106B and MAP6. Live imaging reveals that TMEM106B knockdown and MAP6 overexpression strongly increase retrograde transport of lysosomes in dendrites. Downregulation of MAP6 in TMEM106B knockdown neurons restores the balance of anterograde and retrograde lysosomal transport and thereby prevents loss of dendrites. To strengthen the link, we enhanced anterograde lysosomal transport by expressing dominant-negative Rab7-interacting lysosomal protein (RILP), which also rescues the dendrite loss in TMEM106B knockdown neurons. Thus, TMEM106B/MAP6 interaction is crucial for controlling dendritic trafficking of lysosomes, presumably by acting as a molecular brake for retrograde transport. Lysosomal misrouting may promote neurodegeneration in patients with TMEM106B risk variants. PMID:24357581

  4. Stability of cracked pipe under inertial stresses. Subtask 1.1 final report

    International Nuclear Information System (INIS)

    Scott, P.; Wilson, M.; Olson, R.; Marschall, C.; Schmidt, R.; Wilkowski, G.

    1994-08-01

    This report presents the results of the pipe fracture experiments, analyses, and material characterization efforts performed within Subtask 1.1 of the IPIRG Program. The objective of Subtask 1.1 was to experimentally verify the analysis methodologies for circumferentially cracked pipe subjected primarily to inertial stresses. Eight cracked-pipe experiments were conducted on 6-inch nominal diameter TP304 and A106B pipe. The experimental procedure was developed using nonlinear time-history finite element analyses which included the nonlinear behavior due to the crack. The model did an excellent job of predicting the displacements, forces, and times to maximum moment. The comparison of the experimental loads to the predicted loads by the Net-Section-Collapse (NSC), Dimensionless Plastic-Zone Parameter, J-estimation schemes, R6, and ASME Section XI in-service flaw assessment criteria tended to underpredict the measured bending moments except for the NSC analysis of the A106B pipe. The effects of flaw geometry and loading history on toughness were evaluated by calculating the toughness from the pipe tests and comparing these results to C(l) values. These effects were found to be variable. The surface-crack geometry tended to increase the toughness (relative to CM results), whereas a negative load-ratio significantly decreased the TP304 stainless steel surface-cracked pipe apparent toughness. The inertial experiments tended to achieve complete failure within a few cycles after reaching maximum load in these relatively small diameter pipe experiments. Hence, a load-controlled fracture mechanics analysis may be more appropriate than a displacement-controlled analysis for these tests

  5. Synchrotron radiation leakage from the B-factory beam pipe

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Nelson, W.R.; Ipe, N.

    1990-01-01

    The high-energy ring (HER) of the B-Factory, running at an energy of 9 GeV, generates the synchrotron spectrum when applied to a ring with the PEP bending radius. The B-Factory HER may also run at 12 GeV, producing the harder spectrum. Depending upon beam-pipe material and thickness, some of this radiation may escape and deposit energy in the surrounding material. This was originally pointed out in PEP-109 during the initial design of PEP, and subsequently verified by measurements at both PEP and PETRA at DESY. Of concern to the B Factory is magnet insulation, though other adjacent materials such as wire insulation and cooling water hoses are even more radiosensitive. Radiation damage to magnets is a function of the type of material used in the potting compound. The PEP magnets, which hopefully can be used for the high-energy ring of the B-Factory, are insulated with an epoxy composed of DER-332, DER-732, NMA and aluminum oxide. It is estimated that this epoxy compound should tolerate doses near the 10 10 rad range. To summarize the results of these calculations, 0.87 cm of copper is needed at the point of maximum dose from 12-GeV operation in order to reach the dose criterion if a rectangular beam pipe is used. The copper needs to be only 0.7-cm thick for an octagonal beam pipe and the same energy. For 9-GeV operation, an octagonal copper pipe needs only to be 0.25-cm thick. An octagonal aluminum pipe that is 0.5-cm thick also needs 0.3 cm of lead on the outside to reach the same criterion for 12-GeV operation. For 9-GeV operation, the aluminum pipe still requires a lead liner

  6. Structural design of vacuum bulkheads in piping penetration for the cryostat base of JT-60SA

    International Nuclear Information System (INIS)

    Nakamura, Shigetoshi; Shibama, Yusuke K.; Masaki, Kei

    2016-11-01

    This study examined the structure of the boundary box that is capable of installing the cryostat base of JT-60SA in a narrow space. Since other devices stand close in the neighborhood, it was designed to fit within a limited space to avoid interference. Spatial limitation and generated stress caused by each load were used as design conditions. From the calculation results of the generated stress with respect to each load, the maximum stress is generated by the displacement of the pipeline associated with the displacement of the vacuum container at the time of earthquake and 200degC baking, so bellows were designed to absorb the displacement of the piping. It was confirmed through 3-D finite element analysis that this generated stress is less than the allowable stress and there is no problem in structural integrity. This paper explained the composition of major equipment of JT-60SA and the structure of cryostat base. In the structural analysis of the boundary box, consideration was given to the pressure difference during vacuum closure or abnormal events, temperature distribution, pipe displacement associated with the deformation of vacuum vessel, and seismic load. As a result of finite element analysis, it was confirmed that the displacement amount and temperature distribution during plasma operation and baking were within the allowable range. In addition, the maximum stress during cryostat helium leak was also within the allowable range. (A.O.)

  7. Evaluation of LBB margin of nuclear piping systems

    International Nuclear Information System (INIS)

    Hwang, Il Soon; Kim, Ji Hyeon; Oh, Yeong Jin; Lim, Jun; Kim, In Seob; Kim, Yong Seon; Lee, Joo Seok

    1999-04-01

    Most of previous elastic-plastic fracture studies for LBB assessment of low alloy steel piping have been focused on base metals and weld metals. In contract, the heat affected zone of welded pipe has not been studied in detail primarily because the size of heat affected zone in welded pipe os too small to make specimens for mechanical properties measurement. When structural members are joined by welding, the base metal is heated to its melting point and then cooled rapidly. As a result of this very severe thermal cycle, mechanical properties in the heat affected zone can be degraded by grain coarsening, the precipitation and the segregation of trace impurities. In this study, a thermal and microstructural analysis is performed, and mechanical properties are measured for the weld heat affected zone of SA106Gr.C low allowed piping steel. In addition, inter critical annealing treatment. in two-phase (alpha+gamma) region was performed to investigate the possibilities of improving the toughness and reducing dynamic strain aging (DSA) susceptibility for giving allowable LBB safety margins. From the results, intercritical annealing is shown to give a smaller ductility loss due to DSA than the case of as-received material. Furthermore, the intercritical annealing was able to increase the impact toughness by a factor of 1.5 compared to the as-received material

  8. Evaluation of LBB margin of nuclear piping systems

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Il Soon; Kim, Ji Hyeon; Oh, Yeong Jin; Lim, Jun [Seoul Nationl Univ., Seoul (Korea, Republic of); Kim, In Seob; Kim, Yong Seon; Lee, Joo Seok [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1999-04-15

    Most of previous elastic-plastic fracture studies for LBB assessment of low alloy steel piping have been focused on base metals and weld metals. In contract, the heat affected zone of welded pipe has not been studied in detail primarily because the size of heat affected zone in welded pipe os too small to make specimens for mechanical properties measurement. When structural members are joined by welding, the base metal is heated to its melting point and then cooled rapidly. As a result of this very severe thermal cycle, mechanical properties in the heat affected zone can be degraded by grain coarsening, the precipitation and the segregation of trace impurities. In this study, a thermal and microstructural analysis is performed, and mechanical properties are measured for the weld heat affected zone of SA106Gr.C low allowed piping steel. In addition, inter critical annealing treatment. in two-phase (alpha+gamma) region was performed to investigate the possibilities of improving the toughness and reducing dynamic strain aging (DSA) susceptibility for giving allowable LBB safety margins. From the results, intercritical annealing is shown to give a smaller ductility loss due to DSA than the case of as-received material. Furthermore, the intercritical annealing was able to increase the impact toughness by a factor of 1.5 compared to the as-received material.

  9. Effects of Induction Heat Bending Process on Microstructure and Corrosion Properties of ASME SA312 Gr.TP304 Stainless Steel Pipes

    International Nuclear Information System (INIS)

    Kim, Nam In; Kim, Young Sik; Kim, Kyung Soo; Chang, Hyun Young; Park, Heung Bae; Sung, Gi Ho; Sung, Gi Ho

    2015-01-01

    The usage of bending products recently have increased since many industries such as automobile, aerospace, shipbuilding, and chemical plants need the application of pipings. Bending process is one of the inevitable steps to fabricate the facilities. Induction heat bending is composed of compressive bending process by local heating and cooling. This work focused on the effect of induction heat bending process on the properties of ASME SA312 Gr. TP304 stainless steel pipes. Tests were performed for base metal and bended area including extrados, intrados, crown up, and down parts. Microstructure was analyzed using an optical microscope and SEM. In order to determine intergranular corrosion resistance, Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test and ASTM A262 practice A and C tests were done. Every specimen revealed non-metallic inclusion free under the criteria of 1.5i of the standard and the induction heat bending process did not affect the non-metallic inclusion in the alloys. Also, all the bended specimens had finer grain size than ASTM grain size number 5 corresponding to the grain sizes of the base metal and thus the grain size of the pipe bended by induction heat bending process is acceptable. Hardness of transition start, bend, and transition end areas of ASME SA312 TP304 stainless steel was a little higher than that of base metal. Intergranular corrosion behavior was determined by ASTM A262 practice A and C and DL-EPR test, and respectively step structure, corrosion rate under 0.3 mm/y, and Degree of Sensitization (DOS) of 0.001 - 0.075 % were obtained. That is, the induction heat bending process didn't affect the intergranular corrosion behavior of ASME SA312 TP304 stainless steel

  10. Heat transfer performance of the OPAC 106 heat exchanger; Warmte-overdrachtsprestaties van de OPAC106 warmtewisselaar

    Energy Technology Data Exchange (ETDEWEB)

    De Zwart, H.F.; Janssen, H.J.J. [Wageningen UR Glastuinbouw, Wageningen (Netherlands)

    2010-10-15

    The heat transfer performance of a new type compact heat exchanger were studied. It concerns the OPAC106, developed for the horticultural sector. The OPAC 106 combines a compact size with high heat transfer at low consumption of electricity for air circulation. OPAC stands for Oval Pipe Air Conditioner [Dutch] De warmte-overdrachtprestaties van een nieuw type compacte warmtewisselaar zijn bestudeerd. Het betreft de OPAC106, een speciaal voor de tuinbouw ontwikkelde warmtewisselaar. OPAC betekent Ovale Pijpen Air Conditioner.

  11. Project W-320, 241-C-106 sluicing: Piping calculations. Volume 4

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This supporting document has been prepared to make the FDNW calculations for Project W-320 readily retrievable. The objective of this calculation is to perform the structural analysis of the Pipe Supports designed for Slurry and Supernate transfer pipe lines in order to meet the requirements of applicable ASME codes. The pipe support design loads are obtained from the piping stress calculations W320-27-I-4 and W320-27-I-5. These loads are the total summation of the gravity, pressure, thermal and seismic loads. Since standard typical designs are used for each type of pipe support such as Y-Stop, Guide and Anchors, each type of support is evaluated for the maximum loads to which this type of supports are subjected. These loads are obtained from the AutoPipe analysis and used to check the structural adequacy of these supports

  12. Project W-320, 241-C-106 sluicing: Piping calculations. Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-07-24

    This supporting document has been prepared to make the FDNW calculations for Project W-320 readily retrievable. The objective of this calculation is to perform the structural analysis of the Pipe Supports designed for Slurry and Supernate transfer pipe lines in order to meet the requirements of applicable ASME codes. The pipe support design loads are obtained from the piping stress calculations W320-27-I-4 and W320-27-I-5. These loads are the total summation of the gravity, pressure, thermal and seismic loads. Since standard typical designs are used for each type of pipe support such as Y-Stop, Guide and Anchors, each type of support is evaluated for the maximum loads to which this type of supports are subjected. These loads are obtained from the AutoPipe analysis and used to check the structural adequacy of these supports.

  13. Challenges associated with the current processes for ultrasonic inspection of CANDU reactor feeder piping

    Energy Technology Data Exchange (ETDEWEB)

    Machowski, C. [Babcock & Wilcox Canada Ltd., Cambridge, Ontario (Canada)

    2012-07-01

    CANDU® PHT Feeder Piping is generally constructed from SA106 Grade B carbon steel, which is known to be susceptible to flow accelerated corrosion when exposed to certain environmental conditions. The configuration of the CANDU reactor promotes thinning of the inside surface of the pipe walls, predominantly at the outlet feeders. Inspection of this piping is currently conducted using ultrasonic techniques and is governed by the requirements established by the CANDU Owners Group (COG). There are many challenges associated with these inspections as a result of the complexity of the reactor piping configuration. Geometrical anomalies on the surface of the pipe and non-circular geometries at the tight radius bends hinder the performance of conventional ultrasonic techniques. This can cause lost signals in areas of interest, which in turn often results in rework in order to satisfy the inspection requirements and justify fitness for service of these components. There are also many inspection sites which have limited access due to physical restrictions on the reactor face; therefore in order to maximize the performance of an inspection campaign, it is paramount that the inspection personnel and the inspection technology be well integrated through training simulations prior to execution. These inspection challenges increase the complexity of the analysis process as ultrasonic signals get distorted and lost as a result of non-circular pipe geometries. In order to ensure a high level of integrity in the analysis results, a conservative process is utilized in which two analysts independently examine the data, and a third analyst reviews their results and submits the final call. A Data Management Software application (DMS) is used to input and store the three analysis results. Another important function of the DMS is to provide a communication link between the different work-groups associated with the inspection activities. The focus of this presentation discusses:

  14. General and localized corrosion of carbon and low-alloy steels in oxygenated high-temperature water. Final report

    International Nuclear Information System (INIS)

    Macdonald, D.D.; Smialowska, S.; Pednekar, S.

    1983-02-01

    The susceptibilities to stress corrosion cracking (SCC) of two carbon steels, SA106-grB and SA333-gr6, which are used in seamless BWR piping, and a low-alloy pressure vessel steel, A508-C12, were studied in high purity water as a function of oxygen concentration (0.16 to 8 ppM) and temperature (50 to 288 0 C) . The susceptibility to SCC was measured using the slow strain rate technique. The fracture surfaces of the test specimens were also examined using SEM to determine the mode of failure. In water containing 1 and 8 ppM oxygen and at temperatures above 135 0 C, transgranular stress corrosion cracking (TGSCC) was observed to occur in A508-C12, SA333-gr6 and SA106grB steels at very high stresses. The susceptibility to SCC increased with temperature

  15. Failure Analysis Of Industrial Boiler Pipe

    International Nuclear Information System (INIS)

    Natsir, Muhammad; Soedardjo, B.; Arhatari, Dewi; Andryansyah; Haryanto, Mudi; Triyadi, Ari

    2000-01-01

    Failure analysis of industrial boiler pipe has been done. The tested pipe material is carbon steel SA 178 Grade A refer to specification data which taken from Fertilizer Company. Steps in analysis were ; collection of background operation and material specification, visual inspection, dye penetrant test, radiography test, chemical composition test, hardness test, metallography test. From the test and analysis result, it is shown that the pipe failure caused by erosion and welding was shown porosity and incomplete penetration. The main cause of failure pipe is erosion due to cavitation, which decreases the pipe thickness. Break in pipe thickness can be done due to decreasing in pipe thickness. To anticipate this problem, the ppe will be replaced with new pipe

  16. Elevated TMEM106B levels exaggerate lipofuscin accumulation and lysosomal dysfunction in aged mice with progranulin deficiency.

    Science.gov (United States)

    Zhou, Xiaolai; Sun, Lirong; Brady, Owen Adam; Murphy, Kira A; Hu, Fenghua

    2017-01-26

    Mutations resulting in haploinsufficiency of progranulin (PGRN) cause frontotemporal lobar degeneration with TDP-43-positive inclusions (FTLD-TDP), a devastating neurodegenerative disease. Accumulating evidence suggest a crucial role of progranulin in maintaining proper lysosomal function during aging. TMEM106B has been identified as a risk factor for frontotemporal lobar degeneration with progranulin mutations and elevated mRNA and protein levels of TMEM106B are associated with increased risk for frontotemporal lobar degeneration. Increased levels of TMEM106B alter lysosomal morphology and interfere with lysosomal degradation. However, how progranulin and TMEM106B interact to regulate lysosomal function and frontotemporal lobar degeneration (FTLD) disease progression is still unclear. Here we report that progranulin deficiency leads to increased TMEM106B protein levels in the mouse cortex with aging. To mimic elevated levels of TMEM106B in frontotemporal lobar degeneration (FTLD) cases, we generated transgenic mice expressing TMEM106B under the neuronal specific promoter, CamKII. Surprisingly, we found that the total protein levels of TMEM106B are not altered despite the expression of the TMEM106B transgene at mRNA and protein levels, suggesting a tight regulation of TMEM106B protein levels in the mouse brain. However, progranulin deficiency results in accumulation of TMEM106B protein from the transgene expression during aging, which is accompanied by exaggerated lysosomal abnormalities and increased lipofuscin accumulation. In summary, our mouse model nicely recapitulates the interaction between progranulin and TMEM106B in human patients and supports a critical role of lysosomal dysfunction in the frontotemporal lobar degeneration (FTLD) disease progression.

  17. Tank 241-B-106 tank characterization plan. Revision 1

    International Nuclear Information System (INIS)

    Homi, C.S.

    1995-01-01

    This document is a plan that identifies the information needed to address relevant issues concerning short-term and long-term safe storage and long-term management of Single-Shell Tank (SST) 241-B-106

  18. Sludge pipe flow pressure drop prediction using composite power ...

    African Journals Online (AJOL)

    Sludge pipe flow pressure drop prediction using composite power-law friction ... Water SA. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue ... When predicting pressure gradients for the flow of sludges in pipes, the ...

  19. 225-B ion exchange piping design documentation

    International Nuclear Information System (INIS)

    Prather, M.C.

    1996-02-01

    This document describes the interface between the planned permanent ion exchange piping system and the planned portable ion exchange system. This is part of the Waste Encapsulation and Storage Facility (WESF). In order to decouple this WESF from B-Plant and to improve recovery from a capsule leak, contaminated pool cell water will be recirculated through a portable ion exchange resin system

  20. bHLH106 Integrates Functions of Multiple Genes through Their G-Box to Confer Salt Tolerance on Arabidopsis.

    Science.gov (United States)

    Ahmad, Aftab; Niwa, Yasuo; Goto, Shingo; Ogawa, Takeshi; Shimizu, Masanori; Suzuki, Akane; Kobayashi, Kyoko; Kobayashi, Hirokazu

    2015-01-01

    An activation-tagging methodology was applied to dedifferentiated calli of Arabidopsis to identify new genes involved in salt tolerance. This identified salt tolerant callus 8 (stc8) as a gene encoding the basic helix-loop-helix transcription factor bHLH106. bHLH106-knockout (KO) lines were more sensitive to NaCl, KCl, LiCl, ABA, and low temperatures than the wild-type. Back-transformation of the KO line rescued its phenotype, and over-expression (OX) of bHLH106 in differentiated plants exhibited tolerance to NaCl. Green fluorescent protein (GFP) fused with bHLH106 revealed that it was localized to the nucleus. Prepared bHLH106 protein was subjected to electrophoresis mobility shift assays against E-box sequences (5'-CANNTG-3'). The G-box sequence 5'-CACGTG-3' had the strongest interaction with bHLH106. bHLH106-OX lines were transcriptomically analyzed, and resultant up- and down-regulated genes selected on the criterion of presence of a G-box sequence. There were 198 genes positively regulated by bHLH106 and 36 genes negatively regulated; these genes possessed one or more G-box sequences in their promoter regions. Many of these genes are known to be involved in abiotic stress response. It is concluded that bHLH106 locates at a branching point in the abiotic stress response network by interacting directly to the G-box in genes conferring salt tolerance on plants.

  1. Design specifications for ASME B and PV Code Section III nuclear class 1 piping

    International Nuclear Information System (INIS)

    Richardson, J.A.

    1978-01-01

    ASME B and PV Code Section III code regulations for nuclear piping requires that a comprehensive Design Specification be developed for ensuring that the design and installation of the piping meets all code requirements. The intent of this paper is to describe the code requirements, discuss the implementation of these requirements in a typical Class 1 piping design specification, and to report on recent piping failures in operating light water nuclear power plants in the US. (author)

  2. B Plant process piping replacement feasibility study

    International Nuclear Information System (INIS)

    Howden, G.F.

    1996-01-01

    Reports on the feasibility of replacing existing embedded process piping with new more corrosion resistant piping between cells and between cells and a hot pipe trench of a Hanford Site style canyon facility. Provides concepts for replacement piping installation, and use of robotics to replace the use of the canyon crane as the primary means of performing/supporting facility modifications (eg, cell lining, pipe replacement, equipment reinstallation) and operational maintenenace

  3. Analysis of Fracture Behaviour of Multilayer Pipes

    Czech Academy of Sciences Publication Activity Database

    Nezbedová, E.; Knésl, Zdeněk; Vlach, B.

    2007-01-01

    Roč. 36, č. 5 (2007), s. 207-212 ISSN 1465-8011. [Plastic Pipes /13./. Washington, D. C., 02.10.2006-05.10.2006] R&D Projects: GA ČR GA106/07/1284 Institutional research plan: CEZ:AV0Z20410507 Keywords : multi-layer pipes Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 0.431, year: 2007

  4. Ductile fracture behaviour of primary heat transport piping material ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Abstract. Design of primary heat transport (PHT) piping of pressurised heavy water reactors (PHWR) has to ensure implementation of leak-before-break con- cepts. In order to be able to do so, the ductile fracture characteristics of PHT piping material have to be quantified. In this paper, the fracture resistance of SA333, Grade.

  5. TMEM106B and ApoE polymorphisms in CHMP2B-mediated frontotemporal dementia (FTD-3)

    DEFF Research Database (Denmark)

    Rostgaard, Nina; Roos, Peter; Budtz-Jørgensen, Esben

    2017-01-01

    (ApoE) in FTD is uncertain, though an established risk factor in Alzheimer's disease. In a unique Danish family, inherited FTD is caused by a mutation in the CHMP2B gene located on chromosome 3 (FTD-3). In this family, both risk factors TMEM106B and ApoE were analyzed and correlated to age at onset......Single-nucleotide polymorphisms in the TMEM106B gene have been identified as a risk factor in frontotemporal dementia (FTD). The major allele of SNP rs3173615 is a risk factor in sporadic FTD, whereas the minor allele seems protective in GRN- and C9orf72-mediated FTD. The role of apolipoprotein E...... factor with later AAO and AAI, whereas ε2 seemed to aggravate the disease with earlier AAO and AAD. These results indicate ApoE ε2 as a risk factor in FTD-3 and suggest a protective role of ε4....

  6. Ductile fracture mechanics methodology for complex cracks in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.

    1988-02-01

    Limit load and J-integral estimation solutions are developed for circumferentially complex-cracked pipes in bending. The limit load solution is developed using thick-walled cylinder analysis which included the effects of flaw depth accurately. J-integral estimation solutions are developed that are suitable for a wide range of loading from linear elastic, elastic-plastic to net-section yielding of the flawed section. Mode I stress intensity factor solution is developed from experimental compliance data. Two types of J solutions are developed. First, J solutions for determining the J-resistance curve from single load-displacement record are presented. Next, elastic-plastic J solution in the format of EPRI J estimation scheme is presented. The latter solution was used to predict the load carrying capacity of complex-cracked pipes made of Type-304 stainless steel, Inconel 600, and A106 GrB materials. Predictions were compared against pipe tests to demonstrate the accuracy of the limit load and J estimation solutions.

  7. Ductile fracture mechanics methodology for complex cracks in nuclear piping

    International Nuclear Information System (INIS)

    Zahoor, A.

    1988-01-01

    Limit load and J-integral estimation solutions are developed for circumferentially complex-cracked pipes in bending. The limit load solution is developed using thick-walled cylinder analysis which included the effects of flaw depth accurately. J-integral estimation solutions are developed that are suitable for a wide range of loading from linear elastic, elastic-plastic to net-section yielding of the flawed section. Mode I stress intensity factor solution is developed from experimental compliance data. Two types of J solutions are developed. First, J solutions for determining the J-resistance curve from single load-displacement record are presented. Next, elastic-plastic J solution in the format of EPRI J estimation scheme is presented. The latter solution was used to predict the load carrying capacity of complex-cracked pipes made of Type-304 stainless steel, Inconel 600, and A106 GrB materials. Predictions were compared against pipe tests to demonstrate the accuracy of the limit load and J estimation solutions. (orig.)

  8. MRSA bacteraemia complicating amphotericin B treatment of ...

    African Journals Online (AJOL)

    23 × 106 cells/l. CM was diagnosed following lumbar puncture (positive .... in the SA setting, especially in this vulnerable group of patients, with advanced HIV ... aware of this additional complication of amphotericin B treatment. Cannula sites ...

  9. Assignment of simian rotavirus SA11 temperature-sensitive mutant groups B and E to genome segments

    International Nuclear Information System (INIS)

    Gombold, J.L.; Estes, M.K.; Ramig, R.F.

    1985-01-01

    Recombinant (reassortant) viruses were selected from crosses between temperature-sensitive (ts) mutants of simian rotavirus SA11 and wild-type human rotavirus Wa. The double-stranded genome RNAs of the reassortants were examined by electrophoresis in Tris-glycine-buffered polyacrylamide gels and by dot hybridization with a cloned DNA probe for genome segment 2. Analysis of replacements of genome segments in the reassortants allowed construction of a map correlating genome segments providing functions interchangeable between SA11 and Wa. The reassortants revealed a functional correspondence in order of increasing electrophoretic mobility of genome segments. Analysis of the parental origin of genome segments in ts+ SA11/Wa reassortants derived from the crosses SA11 tsB(339) X Wa and SA11 tsE(1400) X Wa revealed that the group B lesion of tsB(339) was located on genome segment 3 and the group E lesion of tsE(1400) was on segment 8

  10. Assignment of simian rotavirus SA11 temperature-sensitive mutant groups B and E to genome segments

    Energy Technology Data Exchange (ETDEWEB)

    Gombold, J.L.; Estes, M.K.; Ramig, R.F.

    1985-05-01

    Recombinant (reassortant) viruses were selected from crosses between temperature-sensitive (ts) mutants of simian rotavirus SA11 and wild-type human rotavirus Wa. The double-stranded genome RNAs of the reassortants were examined by electrophoresis in Tris-glycine-buffered polyacrylamide gels and by dot hybridization with a cloned DNA probe for genome segment 2. Analysis of replacements of genome segments in the reassortants allowed construction of a map correlating genome segments providing functions interchangeable between SA11 and Wa. The reassortants revealed a functional correspondence in order of increasing electrophoretic mobility of genome segments. Analysis of the parental origin of genome segments in ts+ SA11/Wa reassortants derived from the crosses SA11 tsB(339) X Wa and SA11 tsE(1400) X Wa revealed that the group B lesion of tsB(339) was located on genome segment 3 and the group E lesion of tsE(1400) was on segment 8.

  11. Fracture properties evaluation of stainless steel piping for LBB applications

    International Nuclear Information System (INIS)

    Kim, Y.J.; Seok, C.S.; Chang, Y.S.

    1997-01-01

    The objective of this paper is to evaluate the material properties of SA312 TP316 and SA312 TP304 stainless steels and their associated welds manufactured for shutdown cooling line and safety injection line of nuclear generating stations. A total of 82 tensile tests and 58 fracture toughness tests on specimens taken from actual pipes were performed and the effect of various parameters such as the pipe size, the specimen orientation, the test temperature and the welding procedure on the material properties are discussed. Test results show that the effect of the test temperature on the fracture toughness was significant while the effects of the pipe size and the specimen orientation on the fracture toughness were negligible. The material properties of the GTAW weld metal was in general higher than those of the base metal

  12. Fracture properties evaluation of stainless steel piping for LBB applications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.J.; Seok, C.S.; Chang, Y.S. [Sung Kyun Kwan Univ., Suwon (Korea, Republic of)

    1997-04-01

    The objective of this paper is to evaluate the material properties of SA312 TP316 and SA312 TP304 stainless steels and their associated welds manufactured for shutdown cooling line and safety injection line of nuclear generating stations. A total of 82 tensile tests and 58 fracture toughness tests on specimens taken from actual pipes were performed and the effect of various parameters such as the pipe size, the specimen orientation, the test temperature and the welding procedure on the material properties are discussed. Test results show that the effect of the test temperature on the fracture toughness was significant while the effects of the pipe size and the specimen orientation on the fracture toughness were negligible. The material properties of the GTAW weld metal was in general higher than those of the base metal.

  13. Nuclear piping and pipe support design and operability relating to loadings and small bore piping

    International Nuclear Information System (INIS)

    Stout, D.H.; Tubbs, J.M.; Callaway, W.O.; Tang, H.T.; Van Duyne, D.A.

    1994-01-01

    The present nuclear piping system design practices for loadings, multiple support design and small bore piping evaluation are overly conservative. The paper discusses the results developed for realistic definitions of loadings and loading combinations with methodology for combining loads under various conditions for supports and multiple support design. The paper also discusses a simplified method developed for performing deadweight and thermal evaluations of small bore piping systems. Although the simplified method is oriented towards the qualification of piping in older plants, this approach is applicable to plants designed to any edition of the ASME Section III or B31.1 piping codes

  14. Tensile and fracture properties of primary heat transport system piping material

    International Nuclear Information System (INIS)

    Singh, P.K.; Chattopadhyay, J.; Kushwaha, H.S.

    1997-07-01

    The fracture mechanics calculations in leak-before-break analysis of nuclear piping system require material tensile data and fracture resistance properties in the form of J-R curve. There are large variations in fracture parameters due to variation in chemical composition and process used in making the steel components. Keeping this in view, a comprehensive program has been planned to generate the material data base for primary heat transport system piping using the specimens machined from actual pipes used in service. The material under study are SA333 Gr.6 (base as well as weld) and SA350 LF2 (base). Since the operating temperatures of 500 MWe Indian PHWR PHT system piping range from 260 degC to 304 degC the test temperature chosen are 28 degC, 200 degC, 250 degC and 300 degC. Tensile and compact tension specimens have been fabricated from actual pipe according to ASTM standard. Fracture toughness of base metal has been observed to be higher compared to weld metal in SA333 Gr.6 material for the temperature under consideration. Fracture toughness has been observed to be higher for LC orientation (notch in circumferential direction) compared to CL orientation (notch is in longitudinal direction) for the temperature range under study. Fracture toughness value decreases with increase in temperature for the materials under study. Finally, chemical analysis has been carried out to investigate the reason for high toughness of the material. It has been concluded that low percentage of carbon and nitrogen, low inclusion rating and fine grain size has enhanced the fracture toughness value

  15. MicroRNA-106b-5p regulates cisplatin chemosensitivity by targeting polycystic kidney disease-2 in non-small-cell lung cancer.

    Science.gov (United States)

    Yu, Shaorong; Qin, Xiaobing; Chen, Tingting; Zhou, Leilei; Xu, Xiaoyue; Feng, Jifeng

    2017-09-01

    Systemic therapy with cytotoxic agents remains one of the main treatment methods for non-small-cell lung cancer (NSCLC). Cisplatin is a commonly used chemotherapeutic agent, that, when combined with other drugs, is an effective treatment for NSCLC. However, effective cancer therapy is hindered by a patient's resistance to cisplatin. Unfortunately, the potential mechanism underlying such resistance remains unclear. In this study, we explored the mechanism of microRNA-106b-5p (miR-106b-5p), which is involved in the resistance to cisplatin in the A549 cell line of NSCLC. Quantitative real-time PCR was used to test the expression of miR-106-5p in the A549 and the A549/DDP cell line of NSCLC. The cell counting kit-8 assay was used to detect cell viability. Flow cytometry was used to measure cell cycle and cell apoptosis. Luciferase reporter assays and western blot were performed to confirm whether polycystic kidney disease-2 (PKD2) is a direct target gene of miR-106b-5p. Immunohistochemistry was performed to examine the distribution of PKD2 expression in patients who are sensitive and resistant to cisplatin. The experiments indicated that the expression of miR-106b-5p was significantly decreased in A549/DDP compared with that in A549. MiR-106b-5p affected the tolerance of cells to cisplatin by negatively regulating PKD2. Upregulation of miR-106b-5p or downregulation of PKD2 expression can cause A549/DDP cells to become considerably more sensitive to cisplatin. The results showed that miR-106b-5p enhanced the sensitivity of A549/DDP cells to cisplatin by targeting the expression of PKD2. These findings suggest that the use of miR-106b-5p may be a promising clinical strategy in the treatment of NSCLC.

  16. Effect of dynamic monotonic and cyclic loading on fracture behavior for Japanese carbon steel pipe STS410

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Kanji; Murayama, Kouichi; Ogata, Hiroyuki [and others

    1997-04-01

    The fracture behavior for Japanese carbon steel pipe STS410 was examined under dynamic monotonic and cyclic loading through a research program of International Piping Integrity Research Group (EPIRG-2), in order to evaluate the strength of pipe during the seismic event The tensile test and the fracture toughness test were conducted for base metal and TIG weld metal. Three base metal pipe specimens, 1,500mm in length and 6-inch diameter sch.120, were employed for a quasi-static monotonic, a dynamic monotonic and a dynamic cyclic loading pipe fracture tests. One weld joint pipe specimen was also employed for a dynamic cyclic loading test In the dynamic cyclic loading test, the displacement was controlled as applying the fully reversed load (R=-1). The pipe specimens with a circumferential through-wall crack were subjected four point bending load at 300C in air. Japanese STS410 carbon steel pipe material was found to have high toughness under dynamic loading condition through the CT fracture toughness test. As the results of pipe fracture tests, the maximum moment to pipe fracture under dynamic monotonic and cyclic loading condition, could be estimated by plastic collapse criterion and the effect of dynamic monotonic loading and cyclic loading was a little on the maximum moment to pipe fracture of the STS410 carbon steel pipe. The STS410 carbon steel pipe seemed to be less sensitive to dynamic and cyclic loading effects than the A106Gr.B carbon steel pipe evaluated in IPIRG-1 program.

  17. Effect of dynamic monotonic and cyclic loading on fracture behavior for Japanese carbon steel pipe STS410

    International Nuclear Information System (INIS)

    Kinoshita, Kanji; Murayama, Kouichi; Ogata, Hiroyuki

    1997-01-01

    The fracture behavior for Japanese carbon steel pipe STS410 was examined under dynamic monotonic and cyclic loading through a research program of International Piping Integrity Research Group (EPIRG-2), in order to evaluate the strength of pipe during the seismic event The tensile test and the fracture toughness test were conducted for base metal and TIG weld metal. Three base metal pipe specimens, 1,500mm in length and 6-inch diameter sch.120, were employed for a quasi-static monotonic, a dynamic monotonic and a dynamic cyclic loading pipe fracture tests. One weld joint pipe specimen was also employed for a dynamic cyclic loading test In the dynamic cyclic loading test, the displacement was controlled as applying the fully reversed load (R=-1). The pipe specimens with a circumferential through-wall crack were subjected four point bending load at 300C in air. Japanese STS410 carbon steel pipe material was found to have high toughness under dynamic loading condition through the CT fracture toughness test. As the results of pipe fracture tests, the maximum moment to pipe fracture under dynamic monotonic and cyclic loading condition, could be estimated by plastic collapse criterion and the effect of dynamic monotonic loading and cyclic loading was a little on the maximum moment to pipe fracture of the STS410 carbon steel pipe. The STS410 carbon steel pipe seemed to be less sensitive to dynamic and cyclic loading effects than the A106Gr.B carbon steel pipe evaluated in IPIRG-1 program

  18. Study of vortex breakdown of F-106B by Euler code

    Science.gov (United States)

    Pao, Jenn Louh

    1990-01-01

    The 'Three-dimensional Euler Aerodynamic Method' (TEAM) is presently applied to the F-106B at subsonic speed, in order to examine the relationship between off- and on-surface flow features at angles-of-attack sufficiently great for the occurrence of vortex breakdown. Although TEAM's flow separation is triggered by numerical dissipation, the general trend of vortex-breakdown effect on computed lift characteristics is similar to extant wind tunnel results.

  19. FEM Analysis and Measurement of Residual Stress by Neutron Diffraction on the Dissimilar Overlay Weld Pipe

    International Nuclear Information System (INIS)

    Kim, Kang Soo; Lee, Ho Jin; Woo, Wan Chuck; Seong, Baek Seok; Byeon, Jin Gwi; Park, Kwang Soo; Jung, In Chul

    2010-01-01

    Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-ray method and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic Energy Research Institute). Secondly, FEM Model on the dissimilar overlay weld pipe was made and analyzed by the ABAQUS Code (ABAQUS, 2004). Thermal analysis and stress analysis were performed, and the residual stress was calculated. Thirdly, the results of the FEM analysis were compared with those of the experimental methods

  20. Mycobacterium tuberculosis Modulates miR-106b-5p to Control Cathepsin S Expression Resulting in Higher Pathogen Survival and Poor T-Cell Activation

    Directory of Open Access Journals (Sweden)

    David Pires

    2017-12-01

    Full Text Available The success of tuberculosis (TB bacillus, Mycobacterium tuberculosis (Mtb, relies on the ability to survive in host cells and escape to immune surveillance and activation. We recently demonstrated that Mtb manipulation of host lysosomal cathepsins in macrophages leads to decreased enzymatic activity and pathogen survival. In addition, while searching for microRNAs (miRNAs involved in posttranscriptional gene regulation during mycobacteria infection of human macrophages, we found that selected miRNAs such as miR-106b-5p were specifically upregulated by pathogenic mycobacteria. Here, we show that miR-106b-5p is actively manipulated by Mtb to ensure its survival in macrophages. Using an in silico prediction approach, we identified miR-106b-5p with a potential binding to the 3′-untranslated region of cathepsin S (CtsS mRNA. We demonstrated by luminescence-based methods that miR-106b-5p indeed targets CTSS mRNA resulting in protein translation silencing. Moreover, miR-106b-5p gain-of-function experiments lead to a decreased CtsS expression favoring Mtb intracellular survival. By contrast, miR-106b-5p loss-of-function in infected cells was concomitant with increased CtsS expression, with significant intracellular killing of Mtb and T-cell activation. Modulation of miR-106b-5p did not impact necrosis, apoptosis or autophagy arguing that miR-106b-5p directly targeted CtsS expression as a way for Mtb to avoid exposure to degradative enzymes in the endocytic pathway. Altogether, our data suggest that manipulation of miR-106b-5p as a potential target for host-directed therapy for Mtb infection.

  1. The alkaline pre-filming process of the RWCU piping surface

    Energy Technology Data Exchange (ETDEWEB)

    Kao, D-Y.; Wen, T-J., E-mail: dahyukao@iner.gov.tw [Atomic Energy Council, Inst. of Nuclear Energy Research, Lungtan Taoyuan, Taiwan (China); Fong, C., E-mail: clinton@itri.org.tw [Industrial Technology Research Inst., Chutung, Hsinchu (China); Lu, J-H., E-mail: u879864@taipower.com.tw [Taiwan Power Co., Lungmen Nuclear Power Plant, Gongliao Township, Taipei County (China)

    2010-07-01

    The radiation dose rate on a BWR can cause great damage to operators and their maintenances working quality, so it is very important to lower it. The RWCU of a BWR primary system has the highest radiation dose rate and deposition of an active corrosion product because of: continually cleaning the reactor water and the repeated, acute change of temperature. The Lungmen NPP was built as an advanced BWR (ABWR) system. All new ABWRs in Japan, such as Kashiwazaki-Kariwa NPP units K6 and K7, Hamaoka NPP unit H5, and Shika NPP unit2, were given in passivation treatment in the stage of nuclear heating or flow-induced vibration (FIV) testing before each plant's initial start up. The conditions of alkaline pre-filming process include: pH, dissolve oxygen (DO) and temperature. This project had been decided by the results of earlier water loop testing. Three kinds of specimens including stainless steel AISI SS316L and carbon steel SA106 GrB, SA333 Gr6 were put into the autoclave located at a bypass system during the process of passivation treatment. The materials of these specimens have been used in RWCU piping, and during the alkaline pre-filming process they were monitored by AC impedances and electrochemical corrosion potential (ECP). Their surface analyses including SEM, EDS, ESCA and SIMS data were obtained from the initial test, and obtained every six months thereafter. From the SEM plot of first issue it was found that the specimens' surface of all three different materials presented excellent levels of oxidized pellets. They are almost completely packed, for both large and small granules, and the porosity is less than 40%. The deposition tests of cobalt ion were also completed. The material of stainless steel was nearly not affected through the passive process. However, carbon steel could reduce about 30% to 50% of deposited cobalt ion. This result follows the conclusion of Hatch Company. Based on the nominal cost of radiation protection, i.e. 10000 USD

  2. Design demonstrations for Category B tank systems piping at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-12-01

    Demonstration of the design of the piping systems described in this report is stipulated by the Federal Facility Agreement (FFA) between the U.S. Environmental Protection Agency (EPA)-Region IV, the Tennessee Department of Environment and Conservation (TDEC), and the U.S. Department of Energy (DOE). This report provides a design demonstration of the secondary containment and ancillary equipment of 30 piping systems designated in the FFA as Category B (i.e., existing tank systems with secondary containment). Based on the findings of the Design Demonstrations for the Remaining 19 Category B Tank Systems, (DOE/OR/03-1150 ampersand D2), three tank systems originally designated as Category B have been redesignated as Category C (i.e., existing tank systems without secondary containment). The design demonstrations were developed using information obtained from design drawings (as-built when available), construction specifications, and interviews with facility operators. Each design demonstration addresses system conformance to the requirements of the FFA (Appendix F, Section C). Deficiencies or restrictions regarding the ability to demonstrate that each of the containment systems conforms to FFA requirements are noted in the discussion of each piping system and presented in Table 2.0-1

  3. Defining the association of TMEM106B variants among frontotemporal lobar degeneration patients with GRN mutations and C9orf72 repeat expansions.

    Science.gov (United States)

    Lattante, Serena; Le Ber, Isabelle; Galimberti, Daniela; Serpente, Maria; Rivaud-Péchoux, Sophie; Camuzat, Agnès; Clot, Fabienne; Fenoglio, Chiara; Scarpini, Elio; Brice, Alexis; Kabashi, Edor

    2014-11-01

    TMEM106B was identified as a risk factor for frontotemporal lobar degeneration (FTD) with TAR DNA-binding protein 43 kDa inclusions. It has been reported that variants in this gene are genetic modifiers of the disease and that this association is stronger in patients carrying a GRN mutation or a pathogenic expansion in chromosome 9 open reading frame 72 (C9orf72) gene. Here, we investigated the contribution of TMEM106B polymorphisms in cohorts of FTD and FTD with amyotrophic lateral sclerosis patients from France and Italy. Patients carrying the C9orf72 expansion (n = 145) and patients with GRN mutations (n = 76) were compared with a group of FTD patients (n = 384) negative for mutations and to a group of healthy controls (n = 552). In our cohorts, the presence of the C9orf72 expansion did not correlate with TMEM106B genotypes but the association was very strong in individuals with pathogenic GRN mutations (p = 9.54 × 10(-6)). Our data suggest that TMEM106B genotypes differ in FTD patient cohorts and strengthen the protective role of TMEM106B in GRN carriers. Further studies are needed to determine whether TMEM106B polymorphisms are associated with other genetic causes for FTD, including C9orf72 repeat expansions. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Risk-based replacement strategies for redundant deteriorating reinforced concrete pipe networks

    International Nuclear Information System (INIS)

    Adey, B.; Bernard, O.; Gerard, B.

    2003-01-01

    This paper gives an example of how predictive models of the deterioration of reinforced concrete pipes and the consequences of failure can be used to develop risk-based replacement strategies for redundant reinforced concrete pipe networks. It also shows how an accurate deterioration prediction can lead to a reduction of agency costs, and illustrates the limitation of the incremental intervention step algorithm. The main conclusion is that the use of predictive models, such as those developed by Oxand S.A., in the determination of replacement strategies for redundant reinforced concrete pipe networks can lead to a significant reduction in overall costs for the owner of the structure. (author)

  5. Horizontal transfer of miR-106a/b from cisplatin resistant hepatocarcinoma cells can alter the sensitivity of cervical cancer cells to cisplatin.

    Science.gov (United States)

    Raji, Grace R; Sruthi, T V; Edatt, Lincy; Haritha, K; Sharath Shankar, S; Sameer Kumar, V B

    2017-10-01

    Recent studies indicate that horizontal transfer of genetic material can act as a communication tool between heterogenous populations of tumour cells, thus altering the chemosensitivity of tumour cells. The present study was designed to check whether the horizontal transfer of miRNAs released by cisplatin resistant (Cp-r) Hepatocarcinoma cells can alter the sensitivity of cervical cancer cells. For this exosomes secreted by cisplatin resistant and cisplatin sensitive HepG2 cells (EXres and EXsen) were isolated and characterised. Cytotoxicity analysis showed that EXres can make Hela cells resistant to cisplatin. Analysis of miR-106a/b levels in EXres and EXsen showed that their levels vary. Mechanistic studies showed that miR-106a/b play an important role in EXsen and EXres mediated change in chemosensitivity of Hela cells to cisplatin. Further SIRT1 was identified as a major target of miR-106a/b using in silico tools and this was proved by experimentation. Also the effect of miR-106a/b in chemosensitivity was seen to be dependent on regulation of SIRT1 by miR-106a/b. In brief, this study brings into light, the SIRT1 dependent mechanism of miR-106a/b mediated regulation of chemosensitivity upon the horizontal transfer from one cell type to another. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Project W-320, 241-C-106 sluicing piping calculations, Volume 7

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    The object of this report is to calculate the hydraulic forces imposed at the sluicer nozzle. This is required by Project W-320 waste retrieval for tank 241-C-106. The method of analysis used is Bernoulli's momentum equation for stead flow

  7. Application of tearing modulus stability concepts to nuclear piping. Final report

    International Nuclear Information System (INIS)

    Cotter, K.H.; Chang, H.Y.; Zahoor, A.

    1982-02-01

    The recently developed tearing modulus stability concept was successfully applied to several boiling water reactor (BWR) and pressurized water reactor (PWR) piping systems. Circumferentially oriented through-the-thickness cracks were postulated at numerous locations in each system. For each location, the simplified tearing stability methods developed in USNRC Report NUREG/CR-0838 were used to determine crack stability. The J-T diagram was used to present the results of the computations. The piping systems considered included Type 304 stainless steel as well as A106 carbon steel materials. These systems were analyzed using the piping analysis computer code MINK

  8. TMEM106B, the risk gene for frontotemporal dementia, is regulated by the miRNA-132/212 cluster and affects progranulin pathways

    Science.gov (United States)

    Chen-Plotkin, Alice S.; Unger, Travis L.; Gallagher, Michael D.; Bill, Emily; Kwong, Linda K.; Volpicelli-Daley, Laura; Busch, Johanna I.; Akle, Sebastian; Grossman, Murray; Van Deerlin, Vivianna; Trojanowski, John Q.; Lee, Virginia M.-Y.

    2012-01-01

    Frontotemporal lobar degeneration with TDP-43 inclusions (FTLD-TDP) is a fatal neurodegenerative disease with no available treatments. Mutations in the progranulin gene (GRN) causing impaired production or secretion of progranulin are a common Mendelian cause of FTLD-TDP; additionally, common variants at chromosome 7p21 in the uncharacterized gene TMEM106B were recently linked by genome-wide association to FTLD-TDP with and without GRN mutations. Here we show that TMEM106B is neuronally expressed in postmortem human brain tissue, and that expression levels are increased in FTLD-TDP brain. Furthermore, using an unbiased, microarray-based screen of over 800 microRNAs, we identify microRNA-132 as the top microRNA differentiating FTLD-TDP and control brains, with progranulin in late endo-lysosomes, and TMEM106B over-expression increases intracellular levels of progranulin. Thus, TMEM106B is an FTLD-TDP risk gene, with microRNA-132/212 depression as an event which can lead to aberrant over-expression of TMEM106B, which in turn alters progranulin pathways. Evidence for this pathogenic cascade includes the striking convergence of two independent, genomic-scale screens on a microRNA:mRNA regulatory pair. Our findings open novel directions for elucidating miRNA-based therapies in FTLD-TDP. PMID:22895706

  9. Annual statistic report - Furnas Centrais Eletricas S.A. - 1995

    International Nuclear Information System (INIS)

    1995-01-01

    In this report, extensive statistical data concerning the 1994 activities of the electric utility Furnas Centrais Eletricas S.A. are presented. They include the consumer's market, the generation and supply of electricity and economic and personal information. 106 figs., 71 tabs

  10. 46 CFR 61.15-5 - Steam piping.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Steam piping. 61.15-5 Section 61.15-5 Shipping COAST... Periodic Tests of Piping Systems § 61.15-5 Steam piping. (a) Main steam piping shall be subjected to a... removed and the piping thoroughly examined. (b) All steam piping subject to pressure from the main boiler...

  11. The J-resistance curve Leak-before-Break test program on material for the Darlington Nuclear Generating Station

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1988-01-01

    The Darlington Leak-Before-Break (DLBB) approach has been developed for large diameter (21, 22, 24 inch) SA106B heat transport (HT) piping and SA105 fittings as a design alternative to pipewhip restraints and in recognition of the questionable benefits of providing such restraints. Ontario Hydro's DLBB approach is based on the elastic plastic fracture mechanics method. In this test program, J-resistance curves were determined from actual pipe heats that were used in the construction of the Darlington heat transport systems (Units 1 and 2). Test blocks were prepared using four different welding procedures for nuclear Class I piping. The test program was designed to take into account the effect of various factors such as test temperature, crack plane orientation, welding effects, etc., which have influence on fracture properties. A total of 91 tests were conducted. An acceptable lower bound J-resistance curve for the piping steels was obtained by machining maximum thickness specimens from the pipes and by testing side grooved compact tension specimens. Test results showed that all pipes, welds and heat-affected zone materials within the scope of the DLBB program exhibited uppershelf toughness behaviour. All specimens showed high crack initiation toughness Jsub(lc), rising J-resistance curve and stable and ductile crack extension. Toughness of product forms depended on the direction of crack extension (circumferential versus axial crack orientation). Toughness of DLBB welds and parent materials at 250 0 C was lower than that at 20 0 C. (author)

  12. 49 CFR 572.71 - General description.

    Science.gov (United States)

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES 6-Year-Old Child § 572.71..., “Six-Year-Old Size Child Test Dummy SA106C,” October 28, 1991. (b) The dummy is made up of the... 001, sheet 15 A SA 106C 050 Lumbar Spine Assembly SA 106C 001, sheet 12 A SA 106C 060 Pelvis Assembly...

  13. Sialic acid (SA)-modified selenium nanoparticles coated with a high blood-brain barrier permeability peptide-B6 peptide for potential use in Alzheimer's disease.

    Science.gov (United States)

    Yin, Tiantian; Yang, Licong; Liu, Yanan; Zhou, Xianbo; Sun, Jing; Liu, Jie

    2015-10-01

    The blood-brain barrier (BBB) is a formidable gatekeeper toward exogenous substances, playing an important role in brain homeostasis and maintaining a healthy microenvironment for complex neuronal activities. However, it also greatly hinders drug permeability into the brain and limits the management of brain diseases. The development of new drugs that show improved transport across the BBB represents a promising strategy for Alzheimer's disease (AD) intervention. Whereas, previous study of receptor-mediated endogenous BBB transport systems has focused on a strategy of using transferrin to facilitate brain drug delivery system, a system that still suffers from limitations including synthesis procedure, stability and immunological response. In the present study, we synthetised sialic acid (SA)-modified selenium (Se) nanoparticles conjugated with an alternative peptide-B6 peptide (B6-SA-SeNPs, a synthetic selenoprotein analogue), which shows high permeability across the BBB and has the potential to serve as a novel nanomedicine for disease modification in AD. Laser-scanning confocal microscopy, flow cytometry analysis and inductively coupled plasma-atomic emission spectroscopy ICP-AES revealed high cellular uptake of B6-SA-SeNPs by cerebral endothelial cells (bEnd.3). The transport efficiency of B6-SA-SeNPs was evaluated in a Transwell experiment based on in vitro BBB model. It provided direct evidence for B6-SA-SeNPs crossing the BBB and being absorbed by PC12 cells. Moreover, inhibitory effects of B6-SA-SeNPs on amyloid-β peptide (Aβ) fibrillation could be demonstrated in PC12 cells and bEnd3 cells. B6-SA-SeNPs could not only effectively inhibit Aβ aggregation but could disaggregate preformed Aβ fibrils into non-toxic amorphous oligomers. These results suggested that B6-SA-SeNPs may provide a promising platform, particularly for the application of nanoparticles in the treatment of brain diseases. Alzheimer's disease (AD) is the world's most common form of

  14. 7 CFR 3550.106 - Dwelling requirements.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Dwelling requirements. 3550.106 Section 3550.106... Waste Disposal Grants § 3550.106 Dwelling requirements. (a) Modest dwelling. The property must be one... § 3550.63. (b) Post-repair condition. Dwellings repaired with section 504 funds need not be brought to...

  15. Flow structure in a downward branch pipe with a closed end. Characteristics of flow velocity in the branch pipe

    International Nuclear Information System (INIS)

    Miyoshi, Koji; Nakamura, Akira; Takenaka, Nobuyuki

    2016-01-01

    Many pipes branch off from a main pipe in industrial plants. The penetration of hot water into the branch pipe causes thermal stratification. The thermal stratification layer fluctuates and causes thermal fatigue. The characteristics of velocity distributions in the branch pipe for inner diameters from D_b=21 mm to 43 mm were investigated by laser Doppler velocimetry in this paper. As for the flow in the branch pipe at L=4D_b, the mean velocity of the spiral flow was a simple forced vortex which indicated a straight velocity distribution. The maximum circumferential velocity U_θ _m_a_x and minimum axial velocity U_z _m_i_n at L=4D_b were expressed with D_b and main flow velocity. Empirical formulas were proposed for estimating the distributions of U_θ _m_a_x and U_z _m_i_n in the axial direction. (author)

  16. Project W-320, 241-C-106 sluicing: Construction specification W-320-C1

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits

  17. Stability of cracked pipe under seismic/dynamic displacement-controlled stresses. Subtask 1.2 final report

    International Nuclear Information System (INIS)

    Kramer, G.; Veith, P.; Marschall, C.

    1997-06-01

    Results of displacement-controlled pipe fracture experiments, analyses, and material characterization efforts performed within the International Piping Integrity Research Group, IPIRG, Program Subtask 1.2 are discussed. Effects of dynamic versus quasi-static and monotonic versus cyclic loading were evaluated for ductile tearing of two materials, A106 Grade B ferritic steel and TP304 austenitic steel. Twelve through-wall-cracked pipe experiments were conducted on 6-inch diameter Schedule 120 pipe at 288 C (550 F). The results indicated dynamic loading at seismic strain rates marginally increased the load-carrying capacity of austenitic steel. The ferritic steel tested was sensitive to dynamic strain-aging, and consequently, its load-carrying capacity decreased at dynamic strain rates. Two parameters were found to affect the apparent ductile crack growth resistance during cyclic loading, load ratio (R) and incremental plastic displacement that occurs in a cycle. Cyclic (R = 0) loading had minimal effect on ductile tearing for both materials. However, fully reversed loading decreased the load-carrying capacity and toughness for both materials. The incremental plastic displacement can be as important as the load ratio; however, it is harder to quantify from design stress reports. Large plastic displacements will minimize the effect of negative load ratios

  18. Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography

    International Nuclear Information System (INIS)

    Park, Hee Sang; Choi, Man Yong; Park, Jeong Hak; Lee, Seung Seok; Huh, Yong Hak; Lee, Bo Young; Jae Seong

    2012-01-01

    This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of 10 μm fine hair cracks. but, ultrasound infrared thermography technique was defect detected

  19. 49 CFR 192.277 - Ductile iron pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Ductile iron pipe. 192.277 Section 192.277 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Ductile iron pipe. (a) Ductile iron pipe may not be joined by threaded joints. (b) Ductile iron pipe may...

  20. Application of tearing modulus stability concepts to nuclear piping. Final report. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Cotter, K.H.; Chang, H.Y.; Zahoor, A.

    1982-02-01

    The recently developed tearing modulus stability concept was successfully applied to several boiling water reactor (BWR) and pressurized water reactor (PWR) piping systems. Circumferentially oriented through-the-thickness cracks were postulated at numerous locations in each system. For each location, the simplified tearing stability methods developed in USNRC Report NUREG/CR-0838 were used to determine crack stability. The J-T diagram was used to present the results of the computations. The piping systems considered included Type 304 stainless steel as well as A106 carbon steel materials. These systems were analyzed using the piping analysis computer code MINK.

  1. Project W-320, 241-C-106 sluicing: Construction specification W-320-C2

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits

  2. Project W-320, 241-C-106 sluicing: Construction specification W-320-C2

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-07-20

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits.

  3. Project W-320, 241-C-106 sluicing: Construction specification W-320-C6

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits

  4. Project W-320, 241-C-106 sluicing: Construction specification W-320-C5

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits

  5. Project W-320, 241-C-106 sluicing: Construction specification W-320-C7

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits

  6. Project W-320, 241-C-106 sluicing: Construction specification W-320-C5

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-07-20

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits.

  7. Project W-320, 241-C-106 sluicing: Construction specification W-320-C7

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-07-20

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits.

  8. Project W-320, 241-C-106 sluicing: Construction specification W-320-C6

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-07-20

    This supporting document has been prepared to make the construction specifications for Project W-320 readily available. Project W-320, Waste Retrieval Sluicing System (WRSS), specification is for procurement, fabrication and installation of equipment at the C Tank Farm, including Operator Station and some equipment just outside the C Tank Farm fence, necessary to support the sluicing operation. Work consists of furnishing labor, equipment, and materials to provide the means to procure materials and equipment, fabricate items, excavate and place concrete, and install equipment, piping, wiring, and structures in accordance with the Contract Documents. Major work elements include: Excavation for process and fire protection piping, electrical conduit trenches, and foundations for small structures; Placement of concrete cover blocks, foundations, and equipment pads; Procurement and installation of double walled piping, electrical conduit, fire and raw water piping, chilled water piping, and electrical cable; Procurement and installation of above-ground ventilation system piping between the (HVAC) Process building and Tank C-106; Core drill existing concrete; Furnish and installation of electrical distribution equipment; Installation of the concrete foundation, and assembly installation of the two Seismic Shutdown Systems with Environmental Enclosures; Fabrication and installation of in-pit pipe jumpers, including related valves, instruments and wiring; and Installation of a vertical submersible pump, horizontal booster pump, and winch assembly into tank access riser pits.

  9. 46 CFR 119.430 - Engine exhaust pipe installation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Engine exhaust pipe installation. 119.430 Section 119... INSTALLATION Specific Machinery Requirements § 119.430 Engine exhaust pipe installation. (a) The design of all... an exhaust pipe. (b) Exhaust gas must not leak from the piping or any connections. The piping must be...

  10. TSA suppresses miR-106b-93-25 cluster expression through downregulation of MYC and inhibits proliferation and induces apoptosis in human EMC.

    Science.gov (United States)

    Zhao, Zhi-Ning; Bai, Jiu-Xu; Zhou, Qiang; Yan, Bo; Qin, Wei-Wei; Jia, Lin-Tao; Meng, Yan-Ling; Jin, Bo-Quan; Yao, Li-Bo; Wang, Tao; Yang, An-Gang

    2012-01-01

    Histone deacetylase (HDAC) inhibitors are emerging as a novel class of anti-tumor agents and have manifested the ability to decrease proliferation and increase apoptosis in different cancer cells. A significant number of genes have been identified as potential effectors responsible for the anti-tumor function of HDAC inhibitor. However, the molecular mechanisms of these HDAC inhibitors in this process remain largely undefined. In the current study, we searched for microRNAs (miRs) that were affected by HDAC inhibitor trichostatin (TSA) and investigated their effects in endometrial cancer (EMC) cells. Our data showed that TSA significantly inhibited the growth of EMC cells and induced their apoptosis. Among the miRNAs that altered in the presence of TSA, the miR-106b-93-25 cluster, together with its host gene MCM7, were obviously down-regulated in EMC cells. p21 and BIM, which were identified as target genes of miR-106b-93-25 cluster, increased in TSA treated tumor cells and were responsible for cell cycle arrest and apoptosis. We further identified MYC as a regulator of miR-106b-93-25 cluster and demonstrated its down-regulation in the presence of TSA resulted in the reduction of miR-106b-93-25 cluster and up-regulation of p21 and BIM. More important, we found miR-106b-93-25 cluster was up-regulated in clinical EMC samples in association with the overexpression of MCM7 and MYC and the down-regulation of p21 and BIM. Thus our studies strongly indicated TSA inhibited EMC cell growth and induced cell apoptosis and cell cycle arrest at least partially through the down-regulation of the miR-106b-93-25 cluster and up-regulation of it's target genes p21 and BIM via MYC.

  11. 46 CFR 154.660 - Pipe welding.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pipe welding. 154.660 Section 154.660 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR... § 154.660 Pipe welding. (a) Pipe welding must meet Part 57 of this chapter. (b) Longitudinal butt welds...

  12. 49 CFR Appendix B to Part 192 - Qualification of Pipe

    Science.gov (United States)

    2010-10-01

    ..., “Standard Specification for Carbon and Alloy Steel Pipe, Electric-Fusion-Welded for High Pressure Service at... by reference, see § 192.7). ASTM D2517—Thermosetting plastic pipe and tubing, “Standard Specification...

  13. The effects of cyclic and dynamic loading on the fracture resistance of nuclear piping steels. Technical report, October 1992--April 1996

    Energy Technology Data Exchange (ETDEWEB)

    Rudland, D.L.; Brust, F.; Wilkowski, G.M.

    1996-12-01

    This report presents the results of the material property evaluation efforts performed within Task 3 of the IPIRG-2 Program. Several related investigations were conducted. (1) Quasi-static, cyclic-load compact tension specimen experiments were conducted using parameters similar to those used in IPIRG-1 experiments on 6-inch nominal diameter through-wall-cracked pipes. These experiments were conducted on a TP304 base metal, an A106 Grade B base metal, and their respective submerged-arc welds. The results showed that when using a constant cyclic displacement increment, the compact tension experiments could predict the through-wall-cracked pipe crack initiation toughness, but a different control procedure is needed to reproduce the pipe cyclic crack growth in the compact tension tests. (2) Analyses conducted showed that for 6-inch diameter pipe, the quasi-static, monotonic J-R curve can be used in making cyclic pipe moment predictions; however, sensitivity analyses suggest that the maximum moments decrease slightly from cyclic toughness degradation as the pipe diameter increases. (3) Dynamic stress-strain and compact tension tests were conducted to expand on the existing dynamic database. Results from dynamic moment predictions suggest that the dynamic compact tension J-R and the quasi-static stress-strain curves are the appropriate material properties to use in making dynamic pipe moment predictions.

  14. The effects of cyclic and dynamic loading on the fracture resistance of nuclear piping steels. Technical report, October 1992--April 1996

    International Nuclear Information System (INIS)

    Rudland, D.L.; Brust, F.; Wilkowski, G.M.

    1996-12-01

    This report presents the results of the material property evaluation efforts performed within Task 3 of the IPIRG-2 Program. Several related investigations were conducted. (1) Quasi-static, cyclic-load compact tension specimen experiments were conducted using parameters similar to those used in IPIRG-1 experiments on 6-inch nominal diameter through-wall-cracked pipes. These experiments were conducted on a TP304 base metal, an A106 Grade B base metal, and their respective submerged-arc welds. The results showed that when using a constant cyclic displacement increment, the compact tension experiments could predict the through-wall-cracked pipe crack initiation toughness, but a different control procedure is needed to reproduce the pipe cyclic crack growth in the compact tension tests. (2) Analyses conducted showed that for 6-inch diameter pipe, the quasi-static, monotonic J-R curve can be used in making cyclic pipe moment predictions; however, sensitivity analyses suggest that the maximum moments decrease slightly from cyclic toughness degradation as the pipe diameter increases. (3) Dynamic stress-strain and compact tension tests were conducted to expand on the existing dynamic database. Results from dynamic moment predictions suggest that the dynamic compact tension J-R and the quasi-static stress-strain curves are the appropriate material properties to use in making dynamic pipe moment predictions

  15. Hydraulic simulation of the systems of a nuclear power plant for charges calculation in piping

    International Nuclear Information System (INIS)

    Masriera, N.

    1990-01-01

    This work presents a general description of the methodology used by the ENACE S.A. Fluids Working Group for hydraulics simulation of a nuclear power plant system for the calculation charges in piping. (Author) [es

  16. Experimental modal analysis of the steam inlet pipe to the Chooz B1 high pressure turbine

    International Nuclear Information System (INIS)

    Guihot, O.; Anne, J.P.; Chartain, G.; Le Pironnec, D.

    1993-05-01

    This report presents the results of the modal analysis carried out on one of the steam inlet pipe of the high pressure turbine of the Chooz B1 power plant. This experimental analysis is made within the frame of the research and development project ''dynamical, acoustical and aerodynamical behaviour of the turbogenerator N4''. This research program provides amongst others, numerical studies with the software CIRCUS and ASTER, in order to verify the dynamical behaviour of the designed inlet pipe. The numerical models will be updated from results of the experimental modal analysis to improve the numerical representation of this pipe. All the identified modes in the frequency band [5.2000] Hz are presented in the report. The modal characteristics of the main modes are detailed. Further analysis have been made, in order ease the updating of the numerical models. They consisted in an analysis of the evolution of the dynamical behaviour due to a change of the boundary conditions of the inlet valve frame on one hand and resulting from the presence of an additional mass on the pipe, at the level of the middle flange, on the other hand. The analysis made in low frequency range shows that the pipe is thoroughly embedded in the frame of the high pressure turbine. On the other hand, the boundary conditions on the inlet valve frame are more difficult to determine, because the dynamical behaviour of the valve frame and the upper pipe can not be uncoupled from the considered pipe. The main shell modes of ranks 2, 3 and 4 have been very accurately identified. The most relevant modes to update the numerical models are given. (authors). 48 figs., 18 tabs., 4 refs

  17. Ratchetting behavior of primary heat transport (PHT) piping material SA-333 carbon steel subjected to cyclic loads at room temperature

    International Nuclear Information System (INIS)

    Kulkarni, S.; Desai, Y.M.; Kant, T.; Reddy, G.R.; Gupta, C.; Chakravarthy, J.K.

    2004-01-01

    Ratchetting behavior of SA-333 Gr. 6 carbon steel used as primary heat transport (PHT) piping material has been investigated with three constitutive models proposed by Armstrong-Frederick, Chaboche and Ohno-Wang involving different hardening rules. Performance of the above mentioned models have been evaluated for a broad set of uniaxial and biaxial loading histories. The uniaxial ratchetting simulations have been performed for a range of stress ratios (R) by imposing different stress amplitudes and mean stress conditions. Numerical simulations indicated significant ratchetting and opening of hysteresis loop for negative stress ratio with constant mean stress. Application of cyclic stress without mean stress (R = -1.0) has been observed to produce negligible ratchet-strain accumulation in the material. Simulation under the biaxial stress condition was based on modeling of an internally pressurized thin walled pipe subjected to cyclic bending load. Numerical results have been validated with the experiments as per simulation conditions. All three models have been found to predict the observed accumulation of circumferential strain with increasing number of cycles. However, the Armstrong Frederick (A-F) model was found to be inadequate in simulating the ratchetting response for both uniaxial as well as biaxial loading cases. The A-F model actually over-predicted the ratchetting strain in comparison with the experimental strain values. On the other hand, results obtained with the Chaboche and the Ohno-Wang models for both the uniaxial as well as biaxial loading histories have been observed to closely simulate the experimental results. The Ohno-Wang model resulted in better simulation for the presents sets of experimental results in comparison with the Chaboche model. It can be concluded that the Ohno-Wang model suited well compared to the Chaboche model for above sets of uniaxial and biaxial loading histories. (authors)

  18. Ratcheting study in pressurized piping components under cyclic loading at room temperature

    International Nuclear Information System (INIS)

    Ravi Kiran, A.; Agrawal, M.K.; Reddy, G.R.; Vaze, K.K.; Ghosh, A.K.; Kushwaha, H.S.

    2006-07-01

    The nuclear power plant piping components and systems are often subjected to reversing cyclic loading conditions due to various process transients, seismic and other events. Earlier the design of piping subjected to seismic excitation was based on the principle of plastic collapse. It is believed that during such events, fatigue-ratcheting is likely mode of failure of piping components. The 1995 ASME Boiler and Pressure Vessel code, Section-III, has incorporated the reverse dynamic loading and ratcheting into the code. Experimental and analytical studies are carried out to understand this failure mechanism. The biaxial ratcheting characteristics of SA 333, Gr. 6 steel and SS 304 stainless steel at room temperature are investigated in the present work. Experiments are carried out on straight pipes subjected to internal pressure and cyclic bending load applied in a three point and four point bend test configurations. A shake table test is also carried out on a pressurized elbow by applying sinusoidal base excitation. Analytical simulation of ratcheting in the piping elements is carried out. Chaboche nonlinear kinematic hardening model is used for ratcheting simulation. (author)

  19. Effect of Ovality in Inlet Pigtail Pipe Bends Under Combined Internal Pressure and In-Plane Bending for Ni-Fe-Cr B407 Material

    Directory of Open Access Journals (Sweden)

    Ramaswami P.

    2017-09-01

    Full Text Available The present paper makes an attempt to depict the effect of ovality in the inlet pigtail pipe bend of a reformer under combined internal pressure and in-plane bending. Finite element analysis (FEA and experiments have been used. An incoloy Ni-Fe-Cr B407 alloy material was considered for study and assumed to be elastic-perfectly plastic in behavior. The design of pipe bend is based on ASME B31.3 standard and during manufacturing process, it is challenging to avoid thickening on the inner radius and thinning on the outer radius of pipe bend. This geometrical shape imperfection is known as ovality and its effect needs investigation which is considered for the study. The finite element analysis (ANSYS-workbench results showed that ovality affects the load carrying capacity of the pipe bend and it was varying with bend factor (h. By data fitting of finite element results, an empirical formula for the limit load of inlet pigtail pipe bend with ovality has been proposed, which is validated by experiments.

  20. 46 CFR 182.430 - Engine exhaust pipe installation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Engine exhaust pipe installation. 182.430 Section 182... 100 GROSS TONS) MACHINERY INSTALLATION Specific Machinery Requirements § 182.430 Engine exhaust pipe... equipment might come in contact with an exhaust pipe. (b) Exhaust gas must not leak from the piping or any...

  1. 49 CFR 192.321 - Installation of plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Installation of plastic pipe. 192.321 Section 192... Transmission Lines and Mains § 192.321 Installation of plastic pipe. (a) Plastic pipe must be installed below ground level except as provided by paragraphs (g) and (h) of this section. (b) Plastic pipe that is...

  2. 49 CFR 192.125 - Design of copper pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Design of copper pipe. 192.125 Section 192.125... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Pipe Design § 192.125 Design of copper pipe. (a) Copper... hard drawn. (b) Copper pipe used in service lines must have wall thickness not less than that indicated...

  3. Microbiological corrosion of ASTM SA105 carbon steel pipe for industrial fire water usage

    Science.gov (United States)

    Chidambaram, S.; Ashok, K.; Karthik, V.; Venkatakrishnan, P. G.

    2018-02-01

    The large number of metallic systems developed for last few decades against both general uniform corrosion and localized corrosion. Among all microbiological induced corrosion (MIC) is attractive, multidisciplinary and complex in nature. Many chemical processing industries utilizes fresh water for fire service to nullify major/minor fire. One such fire water service line pipe attacked by micro-organisms leads to leakage which is industrially important from safety point of view. Also large numbers of leakage reported in similar fire water service of nearby food processing plant, paper & pulp plant, steel plant, electricity board etc…In present investigation one such industrial fire water service line failure analysis of carbon steel line pipe was analyzed to determine the cause of failure. The water sample subjected to various chemical and bacterial analyses. Turbidity, pH, calcium hardness, free chlorine, oxidation reduction potential, fungi, yeasts, sulphide reducing bacteria (SRB) and total bacteria (TB) were measured on water sample analysis. The corrosion rate was measured on steel samples and corrosion coupon measurements were installed in fire water for validating non flow assisted localized corrosion. The sulphide reducing bacteria (SRB) presents in fire water causes a localized micro biological corrosion attack of line pipe.

  4. Fully plastic crack opening analyses of complex-cracked pipes for Ramberg-Osgood materials

    International Nuclear Information System (INIS)

    Jeong, Jae Uk; Choi, Jae Boong; Huh, Nam Su; Kim, Yun Jae

    2016-01-01

    The plastic influence functions for calculating fully plastic Crack opening displacement (COD) of complex-cracked pipes were newly proposed based on systematic 3-dimensional (3-D) elastic-plastic Finite element (FE) analyses using Ramberg-Osgood (R-O) relation, where global bending moment, axial tension and internal pressure are considered separately as a loading condition. Then, crack opening analyses were performed based on GE/EPRI concept by using the new plastic influence functions for complex-cracked pipes made of SA376 TP304 stainless steel, and the predicted CODs were compared with FE results based on deformation plasticity theory of tensile material behavior. From the comparison, the confidence of the proposed fully plastic crack opening solutions for complex-cracked pipes was gained. Therefore, the proposed engineering scheme for COD estimation using the new plastic influence functions can be utilized to estimate leak rate of a complex-cracked pipe for R-O material.

  5. Tempus Actas – B 3 em Saúde Coletiva

    Directory of Open Access Journals (Sweden)

    Ana Valéria Machado MENDONCA

    2015-10-01

    Full Text Available Parece que foi ontem, quando lançamos em 2007, o volume 1, número 1 da Revista Tempus Actas em Saúde Coletiva, sob a coordenação da Unidade de Tecnologias da Informação e da Comunicação em Saúde do Núcleo de Estudos em Saúde Pública da Universidade de Brasília. Hoje, passados oito anos, a jovem revista científica, nascida no Centro-Oeste do país, tem ocupado cada vez mais espaços de reconhecimento no Brasil e no mundo, graças ao trabalho hercúleo de sua equipe de colaboradores(as, por sua disciplina e atenção aos novos tempos da comunicação científica que regem as produções de elevado rigor científico.

  6. Seismic test of high temperature piping for HTGR

    International Nuclear Information System (INIS)

    Kobatake, Kiyokazu; Midoriyama, Shigeru; Ooka, Yuzi; Suzuki, Michiaki; Katsuki, Taketsugu

    1983-01-01

    Since the high temperature pipings for the high temperature gas-cooled reactor contain helium gas at 1000 deg C and 40 kgf/cm 2 , the double-walled pipe type consisting of the external pipe serving as the pressure boundary and the internal pipe with heat insulating structure was adopted. Accordingly, their aseismatic design is one of the important subjects. Recently, for the purpose of grasping the vibration characteristics of these high temperature pipings and obtaining the data required for the aseismatic design, two specimens, that is, a double-walled pipe model and a heat-insulating structure, were made, and the vibration test was carried out on them, using a 30 ton vibration table of Kawasaki Heavy Industries Ltd. In the high temperature pipings of the primary cooling system for the multi-purpose, high temperature gas-cooled experimental reactor, the external pipes of 32 B bore as the pressure boundary and the internal pipes of 26 B bore with internal heat insulation consisting of double layers of fiber and laminated metal insulators as the temperature boundary were adopted. The testing method and the results are reported. As the spring constant of spacers is larger and clearance is smaller, the earthquake wave response of double-walled pipes is smaller, and it is more advantageous. The aseismatic property of the heat insulation structure is sufficient. (Kako, I.)

  7. Characterisation of girth pipe weld for primary heat transport system of pressurised heavy water reactors

    International Nuclear Information System (INIS)

    Singh, P.K.; Vaze, K.K.; Kushwaha, H.S.

    2002-01-01

    The weld and heat affected zone (HAZ) associated with the girth weld are most vulnerable regions of the piping system. The different regions of the weld joint such as the weld metal, HAZ and base metal lead to heterogeneous mechanical and metallurgical properties of the joints. Due to their different metallurgical and mechanical properties, the amounts of damage produced in these regions are different when the component is subjected to service condition. Thus, it is imperative to know the characteristics of these regions of a pipe weld in order to identify the weakest zone for safe designing of high energy piping components. In view of this necessity the present study has been planned to carry out complete characterisation of the weld joint of SA 333 Gr.6 steel pipe, in terms of its metallurgical, mechanical and fracture properties. The mechanical and fracture mechanics properties of the base metal, weld deposit and HAZ have been compared and correlated with reference to their microstructures. Weld joints of SA 333 Gr.6 steel pipe have been prepared by using GTAW root pass and SMAW filling of V-grove as per recommended welding procedure specifications (WPS) conforming to ASME Sec IX commonly used to fabricate nuclear piping system components. The emphasis of the study is to characterise base, weld and HAZ of the pipe weld in terms of chemical, metallurgical, mechanical and fracture mechanics properties. The fracture toughness behaviour of the welds and HAZ has been characterised by J-integral parameters. The fatigue crack growth rate has been characterised by Paris Law. Stretched zone width (SZW) has been measured under SEM to evaluate initiation fracture toughness. The estimated initiation fracture toughness based on SZW and blunting line given by EGF recommendation have been compared. The fracture mechanics properties of base, weld and HAZ has been determined and compared. The fracture mechanics properties of the weld and HAZ have been correlated to their

  8. Gel structure of the corrosion layer on cladding pipes of nuclear fuels

    Czech Academy of Sciences Publication Activity Database

    Medek, Jiří; Weishauptová, Zuzana

    2009-01-01

    Roč. 393, č. 2 (2009), s. 306-310 ISSN 0022-3115 R&D Projects: GA ČR GA106/04/0043 Institutional research plan: CEZ:AV0Z30460519 Keywords : cladding pipes of nuclear fuels * corrosion layer * zirconium alloys Subject RIV: JF - Nuclear Energetics Impact factor: 1.933, year: 2009

  9. iB1350 no.3. Passive double confinement and SA population dose evaluation for the iB1350

    International Nuclear Information System (INIS)

    Sato, Takashi; Matsumoto, Keiji; Hosomi, Kenji; Iwasaki, Ryuji

    2017-01-01

    passively no emergency evacuation outside the immediate vicinity of the plant for a SA. Furthermore, there is the severe accident standby gas treatment system (SASGTS). It is an active filtration system for a SA that can function during a SA. The iB1350 enables no land contamination with the SASGTS. The results of population dose evaluation using 'RADTRAD' code show excellent performance of the FP confinement of the iB1350. (author)

  10. 27 CFR 21.106 - Diethyl phthalate.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Diethyl phthalate. 21.106....106 Diethyl phthalate. (a) Refractive index at 25 °C. 1.497 to 1.502. (b) Color. Colorless. (c) Odor... °/25 °C. 1.115 to 1.118. (f) Ester content (as diethyl phthalate). Not less than 99 percent by weight...

  11. Special fracture mechanics specimens for multilayer plastic pipes testing

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  12. 46 CFR 45.153 - Through-hull piping: General.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Through-hull piping: General. 45.153 Section 45.153... Conditions of Assignment § 45.153 Through-hull piping: General. (a) All through-hull pipes required by this subpart must be made of steel or material equivalent to the hull in strength and fatigue resistance. (b...

  13. 13 CFR 106.500 - What is SBA's Gift authority?

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false What is SBA's Gift authority? 106... AND NON-FEE BASED SBA-SPONSORED ACTIVITIES AND GIFTS Gifts § 106.500 What is SBA's Gift authority? This section covers SBA's Gift acceptance authority under sections 4(g), 8(b)(1)(G), 5(b)(9) and 7(k)(2...

  14. 46 CFR 34.25-15 - Piping-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... requirements of subchapter F (Marine Engineering) of this chapter. (b) Distribution piping shall be of materials resistant to corrosion, except that steel or iron pipe may be used if inside corrosion resistant...

  15. Plastic influence functions for calculating J-integral of complex-cracks in pipe

    International Nuclear Information System (INIS)

    Jeong, Jae-Uk; Choi, Jae-Boong; Kim, Moon-Ki; Huh, Nam-Su; Kim, Yun-Jae

    2016-01-01

    In this study, the plastic influence functions, h_1, for estimates of J-integral of a pipe with a complex crack were newly proposed based on the systematic 3-dimensional (3-D) elastic-plastic finite element (FE) analyses by using Ramberg-Osgood (R-O) relation, in which global bending moment, axial tension and internal pressure were considered as loading conditions. Based on the present plastic influence functions, the GE/EPRI-type J-estimation scheme for complex-cracked pipes was suggested, and the results from the proposed J-estimation were compared with the FE results using both R-O fit parameters and actual tensile data of SA376 TP304 stainless steel. The comparison results demonstrate that although the proposed scheme provided sensitive J estimations according to fitting ranges of R-O parameters, it showed overall good agreements with the FE results using R-O relation. Thus, the proposed engineering J prediction method can be utilized to assess instability of a complex crack in pipes for R-O material. - Highlights: • New h_1values of GE/EPRI method for complex-cracked pipes are proposed. • The plastic limit loads of complex-cracked pipes using Mises yield criterion are provided. • The new J estimates of complex-cracked pipes are proposed based on GE/EPRI concept. • The proposed estimates for J are validated against 3-D finite element results.

  16. Direito à saúde e saneamento básico na estratégia saúde da família no Complexo do Alemão = Right to health and basic sanitation in health strategy to the family in “Complexo do Alemão”

    OpenAIRE

    Simony Costa Oliveira; Liliana Angel Vargas

    2010-01-01

    Este artigo surge o interesse de estimular a reflexão sobre as possibilidades da garantia do direito ao saneamento básico no Complexo do Alemão - Rio de Janeiro, Estado do Rio de Janeiro a partir da Estratégia da Saúde da Família (ESF), na medida em que seentende o direito ao saneamento básico intimamente integrado ao direito à saúde. O estudo se propôs identificar a percepção dos profissionais que atuam na Unidade de Saúde da Família (USF) Nova Brasília sobre o direito a saneamento básico, a...

  17. Investigations into the triggered lightning response of the F106B thunderstorm research aircraft

    Science.gov (United States)

    Rudolph, Terence H.; Perala, Rodney A.; Mckenna, Paul M.; Parker, Steven L.

    1985-01-01

    An investigation has been conducted into the lightning characteristics of the NASA F106B thunderstorm research aircraft. The investigation includes analysis of measured data from the aircraft in the time and frequency domains. Linear and nonlinear computer modelling has also been performed. In addition, new computer tools have been developed, including a new enhanced nonlinear air breakdown model, and a subgrid model useful for analyzing fine details of the aircraft's geometry. Comparison of measured and calculated electromagnetic responses of the aircraft to a triggered lightning environment are presented.

  18. Evaluation of fatigue crack growth and fracture resistance of SA350 LF2 material

    International Nuclear Information System (INIS)

    Singh, P.K.; Dubey, J.S.; Chakrabarty, J.K.; Vaze, K.K.; Kushwaha, H.S.

    2003-01-01

    The aim of the present paper is to evaluate the tensile and fracture mechanics properties of the SA350 LF2 carbon steel material used as the Header material in the primary heat transport (PHT) system piping of the Indian pressurized heavy water reactors (PHWR). Tensile, fatigue crack growth rate and fracture toughness tests have been carried out on specimens machined from the Header of the actual PHT pipes. The effect of temperature on tensile properties has been discussed. The effect of temperature and notch orientation on fracture resistance behavior of the material and fatigue crack growth rate dependence on the notch orientation and stress ratio has also been discussed. (author)

  19. Failure behavior of a pipe system with a circumferentially orientated flaw - analytical and experimental investigations

    International Nuclear Information System (INIS)

    Mikkola, T.P.J.; Diem, H.; Blind, D.; Hunger, H.

    1989-01-01

    At the german HDR-test-facility a pipe failure experiment was performed at a fullsize feedwater piping system under operating conditions of T=240 0 C, p=10.6 MPa and with an elevated oxygen content in the pressure medium. The loading was internal pressure and a cyclic varying bending moment with an R-ratio of 0.5. The in form of a circumferentially orientated notch initially weakened piping system failed after a total number of 4773 loaded cycles with different frequencies in form of a small leak. The analyses of the fracture surface indicated the strongly growing influence of corrosion effects on the crack propagation rate with decreasing loading frequency. The cyclic crack growth and the leak-before-break behavior of the piping system could be explained on the basis of results of finite element calculations using ADINA-code. (orig.)

  20. Saúde do idoso e execução da política nacional da pessoa idosa nas ações realizadas na atenção básica à saúde

    Directory of Open Access Journals (Sweden)

    VIEIRA, Roseli Schminski

    2016-03-01

    Full Text Available A Política Nacional de Saúde da Pessoa Idosa (PNSPI foi formulada pelo Ministério da Saúde por meio da Portaria n. 2.528/2006, em consonância com a Constituição de 1988. O estudo investigou se os municípios de uma região do Sul do Estado de Santa Catarina conhecem e aplicam a PNSPI durante as ações realizadas na atenção básica à saúde, em especial nas Unidades de Estratégia de Saúde da Família, à luz do que dispõem a Constituição e o Estatuto do Idoso. Na pesquisa, utilizou-se o método dedutivo, com abordagem qualitativa e pesquisa descritiva. Como resultados, destacam-se as dificuldades apresentadas pelos sujeitos da pesquisa acerca de dois pontos importantes das diretrizes e estratégias da PNSPI: a falta de uma política planejada e contínua de educação em saúde para os idosos; e a inexistência de estímulo ao exercício do controle social, no âmbito seja da saúde, seja do Conselho Municipal da Pessoa Idosa.

  1. Application of leak-before-break to primary loop piping to eliminate pipe whip restraints in a Spanish nuclear power plant

    International Nuclear Information System (INIS)

    Rodriguez, M.; Esteban, A.

    1990-01-01

    The Spanish plant described in this study is a 982 MWe PWR with a three-loop primary circuit of piping made from centrifugally-cast stainless steel SA351 CF8A. The licensee requested from Consejo de Seguridad Nuclear (CSN) an exemption from the general design criterion, GDC-4, so as to avoid the need to postulate a guillotine rupture of the primary loop piping. The request was based on the generic work performed for a US PWR plant group in order to have such an exemption. As the piping material in the Spanish plant is different from that in the plants included in the generic work, CSN performed a review of the applicability of the generic results to the Spanish plant. Also, aspects such as fatigue evaluation, net section collapse, crack growth and leak detection, specifically analyzed for the Spanish plant, were reviewed. CSN found that fracture toughness test results from generic work are applicable to the Spanish plant; sufficient margin exists against unstable crack extension, and adequate leak detection capability exists with the leakage detection systems available in the plant. Exemption from GDC-4 was approved and CSN authorized the licensee to remove protection devices against dynamic loads from guillotine breaks in the primary coolant loops. (author)

  2. Promoção da saúde, qualidade de vida e iniquidade em saúde: reflexões para a saúde pública.

    Directory of Open Access Journals (Sweden)

    Aline Rodrigues de ALMEIDA

    2016-01-01

    Full Text Available A ideia de promover saúde tem se tornado uma energia fundamental no movimento de saúde coletiva, no qual saúde é um fenômeno social e marcado por iniquidades. Este trabalho teve como objetivo compreender as relações entre promoção da saúde e iniquidades de acesso e assistência em saúde, identificandoos entraves para uma prática equânime da saúde pública com ênfase à qualidade de vida. Os diferentes perfis de doença e suas mediações sociais ultrapassam os estudos de variação biológica e incorpora o foco na dimensão social das vulnerabilidades. Para promover saúde no Brasil, é indissociável do enfrentamento de uma realidade de iniquidades históricas de grandes proporções que impõem desafios cotidianos não apenas ao setor de saúde, mas a todos aqueles que constroem políticas públicas. A qualidade de vida depende da satisfação das necessidades básicas de todos os cidadãos, propondo uma gestão baseada na solidariedade social, uma visão holística dos problemas e a redução das iniquidades. A promoção da saúde em um país tão desigual como o Brasil propõe um desafio constante aos atores envolvidos no sistema de saúde. A compreensão das iniquidades em saúde para estabelecer uma assistência holística é um processo difícil, mas extremamente relevante para a saúde pública.

  3. Comparison of applicability of current transition temperature shift models to SA533B-1 reactor pressure vessel steel of Korean nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Lee, Bong Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-08-15

    The precise prediction of radiation embrittlement of aged reactor pressure vessels (RPVs) is a prerequisite for the long-term operation of nuclear power plants beyond their original design life. The expiration of the operation licenses for Korean reactors the RPVs of which are made from SA533B-1 plates and welds is imminent. Korean regulatory rules have adopted the US Nuclear Regulatory Commission's transition temperature shift (TTS) models to the prediction of the embrittlement of Korean reactor pressure vessels. The applicability of the TTS model to predict the embrittlement of Korean RPVs made of SA533B-1 plates and welds was investigated in this study. It was concluded that the TTS model of 10 CFR 50.61a matched the trends of the radiation embrittlement in the SA533B-1 plates and welds better than did that of Regulatory Guide (RG) 1.99 Rev. 2. This is attributed to the fact that the prediction performance of 10 CFR 50.61a was enhanced by considering the difference in radiation embrittlement sensitivity among the different types of RPV materials.

  4. 5 CFR 9901.106 - Relationship to other provisions.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Relationship to other provisions. 9901.106 Section 9901.106 Administrative Personnel DEPARTMENT OF DEFENSE HUMAN RESOURCES MANAGEMENT AND....S.C. 5545b; and (iii) Recruitment, relocation, and retention payments under 5 U.S.C. 5753 through...

  5. Design demonstrations for Category B tank system piping at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-02-01

    Demonstration of the design of the tank systems described in this report is stipulated by the Federal Facility Agreement (FFA) between the U.S. Environmental Protection Agency-Region IV, the Tennessee Department of Environment and Conservation, and the U.S. Department of Energy. This report provides a design demonstration of the secondary containment and ancillary equipment of 30 piping systems listed in the FFA as Category B (i.e., existing tank systems with secondary containment). The design demonstrations were developed using information obtained from design drawings (as-built when available), construction specifications, and interviews with facility operators. Each design demonstration addresses system conformance to the requirements of the FFA (Appendix F, Section C). Deficiencies or restrictions regarding the ability to demonstrate that each of the containment systems conforms to FFA requirements are noted in the discussion of each piping system

  6. 46 CFR 194.20-19 - Piping and electrical requirements.

    Science.gov (United States)

    2010-10-01

    ... Storerooms § 194.20-19 Piping and electrical requirements. (a) Piping, electrical equipment, and wiring shall... storeroom itself. (b) The electrical installation shall be in accordance with the applicable requirements of...

  7. 49 CFR 192.287 - Plastic pipe: Inspection of joints.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Plastic pipe: Inspection of joints. 192.287... Than by Welding § 192.287 Plastic pipe: Inspection of joints. No person may carry out the inspection of joints in plastic pipes required by §§ 192.273(c) and 192.285(b) unless that person has been qualified by...

  8. 20 CFR 653.106 - JS day-haul responsibilities.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false JS day-haul responsibilities. 653.106 Section... THE EMPLOYMENT SERVICE SYSTEM Services for Migrant and Seasonal Farmworkers (MSFWs) § 653.106 JS day... Regional Administrator is obtained. (b) No JS applicants shall be referred to non-JS operated day-haul...

  9. 46 CFR 182.445 - Fill and sounding pipes for fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fill and sounding pipes for fuel tanks. 182.445 Section... pipes for fuel tanks. (a) Fill pipes for fuel tanks must be not less than 40 millimeters (1.5 inches) nominal pipe size. (b) There must be a means of accurately determining the amount of fuel in each fuel...

  10. 46 CFR 119.445 - Fill and sounding pipes for fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fill and sounding pipes for fuel tanks. 119.445 Section... INSTALLATION Specific Machinery Requirements § 119.445 Fill and sounding pipes for fuel tanks. (a) Fill pipes for fuel tanks must be not less than 40 millimeters (1.5 inches) nominal pipe size. (b) There must be...

  11. As invasões bárbaras do Brasil e do Canadá (Quebec : Sistema Público de Saúde não funciona

    Directory of Open Access Journals (Sweden)

    Charmain Levy Levy

    2015-07-01

    Full Text Available Resumo : Refletir sobre a funcionalidade das novas vidas diante dos inúmeros cenários e desafios que são oferecidos ao longo do cotidiano, está e a proposta deste texto. As invasões bárbaras que sucedem ao longo da história passam pelos navegantes e aportam na corrupção e no cativeiro da qualidade de vida de uma liberdade prometida. A promoção da saúde e o eixo norteador deste dialogo com referência sobre os sistemas de saúde do Brasil e do Canada. O objeto de intercepção e a universalidade e a igualdade de atenção e acesso aos serviços e a atenção de saúde. Para o momento pós movimentos sociais reivindicatórios no Brasil e apresentado um convite para a responsabilização e a autonomia em saúde, sugerimos iniciativas e o assumir de vontades que podem se traduzir em atitudes de trazer para si e assumir a parte que nos compete nas etapas de crescimento e desenvolvimento pessoal e social para termos uma saúde pública equânime e universal como um direito Humano e de cidadania. Palavras chave : Promoção da saúde, Sistema de saúde, Política de saúde Brasil, Politica de saúde Canadá.

  12. Atenção à saúde mental na rede básica: estudo sobre a eficácia do modelo assistencial

    Directory of Open Access Journals (Sweden)

    Márcia A. do Amaral

    1997-06-01

    Full Text Available INTRODUÇÃO: Objetivou-se analisar a implementação da política de saúde mental para a rede básica de saúde, no Município de Campinas, SP (Brasil. MATERIAL E MÉTODO: Foi feito estudo epidemiológico descritivo de uma amostra de 150 pacientes egressos de um hospital psiquiátrico e encaminhados aos centros de saúde para continuidade do tratamento. Durante 4 meses após a alta, foi verificado o comparecimento dos pacientes às atividades, assim como a ocorrência de reinternações. RESULTADOS: Foram encontrados 48,6% dos pacientes em alta hospitalar que não demandaram atendimento nos centros de saúde e dos que o fizeram, 51,4% abandonaram o tratamento num período de 4 meses. A prevalência de reinternações em 4 meses foi de 24,7%, sendo maior entre os pacientes com diagnóstico de psicoses. CONCLUSÕES: Foram evidenciados problemas na implementação da política de saúde mental para a rede básica relativos à definição das políticas, à organização do processo de trabalho das equipes de saúde e aos resultados alcançados. Foi referendado o diagnóstico de que a transformação do modelo manicomial demanda a existência de novos equipamentos de reabilitação psicossocial e a articulação intersetorial para alcançar seus objetivos de desospitalização e resgate da cidadania dos doentes mentais.

  13. Crack propagation in touch ductile materials. Phase II

    International Nuclear Information System (INIS)

    Venter, R.D.; Sinclair, A.N.; McCammond, D.

    1989-06-01

    The thrust of this work was to investigate published J material resistance and stress-strain data applicable to the understanding of crack propagation in tough ductile steels, particularly SA 106 Grade B pipe steel. This data has been assembled from PIFRAC, AECB report INFO-0254-1 and Ontario Hydro sources and has been uniformly formatted and presented to facilitate comparison and assessment. While the data is in many aspects incomplete it has enabled an evaluation of the influence of temperature, specimen thickness and specimen orientation to be made in the context of the experimental J-R curves so determined. Comparisons of the stress-strain data within the Ramburg-Osgood formulation are also considered. A further component of this report addresses the development of the required software to utilize what is referred to as the engineering approach to elasto-plastic analysis to investigate the load carrying capacity of selected cracked pipe geometries which are representative of applied crack propagation studies associated with piping systems in the nuclear industry. Three specific geometries and loading situations, identified as Condition A, B and C have been evaluated; the results are presented and illustrate the variation in applied load as a function of an initial and final crack extension leading to instability

  14. Pipe-to-pipe impact program

    International Nuclear Information System (INIS)

    Alzheimer, J.M.; Bampton, M.C.C.; Friley, J.R.; Simonen, F.A.

    1984-06-01

    This report documents the tests and analyses performed as part of the Pipe-to-Pipe Impact (PTPI) Program at the Pacific Northwest Laboratory. This work was performed to assist the NRC in making licensing decisions regarding pipe-to-pipe impact events following postulated breaks in high energy fluid system piping. The report scope encompasses work conducted from the program's start through the completion of the initial hot oil tests. The test equipment, procedures, and results are described, as are analytic studies of failure potential and data correlation. Because the PTPI Program is only partially completed, the total significance of the current test results cannot yet be accurately assessed. Therefore, although trends in the data are discussed, final conclusions and recommendations will be possible only after the completion of the program, which is scheduled to end in FY 1984

  15. Desafio para a atenção básica: incorporação da assistência em saúde mental

    Directory of Open Access Journals (Sweden)

    Oswaldo Yoshimi Tanaka

    Full Text Available Com o objetivo de avaliar a atenção em saúde mental na atenção básica de saúde foi realizado um estudo comparativo entre os diagnósticos de Problemas de Saúde Mental (PSM, realizados pelos pediatras, e os prováveis PSM identificados por meio da aplicação de um questionário padronizado (CBCL. O estudo foi realizado com crianças de 5 a 11 anos atendidas em uma unidade básica de saúde (UBS, entre agosto e outubro de 2002, no Município de São Paulo, Brasil. Para aprofundar a análise foram realizadas 11 entrevistas com os pediatras da UBS. A análise de 411 prontuários e dos 206 questionários aplicados aos pais, mostram que os pediatras realizaram diagnóstico de PSM em 17,5% das crianças atendidas. Quando comparado com os prováveis PSM identificados pelo CBCL, apenas 25,3% das crianças são identificadas com PSM pelos médicos. A entrevista realizada com os pediatras identifica dificuldades na definição de PSM, a carência de instrumentos para o reconhecimento dos problemas e falta de um sistema de encaminhamento, e carecem de apoio técnico específico.

  16. 49 CFR 179.400-17 - Inner tank piping.

    Science.gov (United States)

    2010-10-01

    ... connected to this line to operate at their design capacity without excessive pressure build-up in the tank... housing and must be directed upward and away from operating personnel. (b) Any pressure building system...-17 Inner tank piping. (a) Product lines. The piping system for vapor and liquid phase transfer and...

  17. Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests

    International Nuclear Information System (INIS)

    Baum, M.R.

    1987-01-01

    This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author)

  18. Measurement of the decays B--> phiK and B--> phiK*.

    Science.gov (United States)

    Aubert, B; Boutigny, D; Gaillard, J M; Hicheur, A; Karyotakis, Y; Lees, J P; Robbe, P; Tisserand, V; Palano, A; Chen, G P; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Reinertsen, P L; Stugu, B; Abbott, B; Abrams, G S; Borgland, A W; Breon, A B; Brown, D N; Button-Shafer, J; Cahn, R N; Clark, A R; Fan, Q; Gill, M S; Gowdy, S J; Gritsan, A; Groysman, Y; Jacobsen, R G; Kadel, R W; Kadyk, J; Kerth, L T; Kluth, S; Kolomensky, Y G; Kral, J F; LeClerc, C; Levi, M E; Liu, T; Lynch, G; Meyer, A B; Momayezi, M; Oddone, P J; Perazzo, A; Pripstein, M; Roe, N A; Romosan, A; Ronan, M T; Shelkov, V G; Telnov, A V; Wenzel, W A; Bright-Thomas, P G; Harrison, T J; Hawkes, C M; Kirk, A; Knowles, D J; O'Neale, S W; Penny, R C; Watson, A T; Watson, N K; Deppermann, T; Koch, H; Krug, J; Kunze, M; Lewandowski, B; Peters, K; Schmuecker, H; Steinke, M; Andress, J C; Barlow, N R; Bhimji, W; Chevalier, N; Clark, P J; Cottingham, W N; De Groot, N; Dyce, N; Foster, B; Mass, A; McFall, J D; Wallom, D; Wilson, F F; Abe, K; Hearty, C; Mattison, T S; McKenna, J A; Thiessen, D; Camanzi, B; Jolly, S; McKemey, A K; Tinslay, J; Blinov, V E; Bukin, A D; Bukin, D A; Buzykaev, A R; Dubrovin, M S; Golubev, V B; Ivanchenko, V N; Korol, A A; Kravchenko, E A; Onuchin, A P; Salnikov, A A; Serednyakov, S I; Skovpen, Y I; Telnov, V I; Yushkov, A N; Lankford, A J; Mandelkern, M; McMahon, S; Stoker, D P; Ahsan, A; Arisaka, K; Buchanan, C; Chun, S; Branson, J G; MacFarlane, D B; Prell, S; Rahatlou, S; Raven, G; Sharma, V; Campagnari, C; Dahmes, B; Hart, P A; Kuznetsova, N; Levy, S L; Long, O; Lu, A; Richman, J D; Verkerke, W; Witherell, M; Yellin, S; Beringer, J; Dorfan, D E; Eisner, A M; Frey, A; Grillo, A A; Grothe, M; Heusch, C A; Johnson, R P; Kroeger, W; Lockman, W S; Pulliam, T; Sadrozinski, H; Schalk, T; Schmitz, R E; Schumm, B A; Seiden, A; Turri, M; Walkowiak, W; Williams, D C; Wilson, M G; Chen, E; Dubois-Felsmann, G P; Dvoretskii, A; Hitlin, D G; Metzler, S; Oyang, J; Porter, F C; Ryd, A; Samuel, A; Weaver, M; Yang, S; Zhu, R Y; Devmal, S; Geld, T L; Jayatilleke, S; Mancinelli, G; Meadows, B T; Sokoloff, M D; Bloom, P; Fahey, S; Ford, W T; Gaede, F; Johnson, D R; Michael, A K; Nauenberg, U; Olivas, A; Park, H; Rankin, P; Roy, J; Sen, S; Smith, J G; van Hoek, W C; Wagner, D L; Blouw, J; Harton, J L; Krishnamurthy, M; Soffer, A; Toki, W H; Wilson, R J; Zhang, J; Brandt, T; Brose, J; Colberg, T; Dahlinger, G; Dickopp, M; Dubitzky, R S; Maly, E; Müller-Pfefferkorn, R; Otto, S; Schubert, K R; Schwierz, R; Spaan, B; Wilden, L; Behr, L; Bernard, D; Bonneaud, G R; Brochard, F; Cohen-Tanugi, J; Ferrag, S; Roussot, E; T'Jampens, S; Thiebaux, C; Vasileiadis, G; Verderi, M; Anjomshoaa, A; Bernet, R; Di Lodovico, F; Khan, A; Muheim, F; Playfer, S; Swain, J E; Falbo, M; Bozzi, C; Dittongo, S; Folegani, M; Piemontese, L; Treadwell, E; Anulli, F; Baldini-Ferroli, R; Calcaterra, A; de Sangro, R; Falciai, D; Finocchiaro, G; Patteri, P; Peruzzi, I M; Piccolo, M; Xie, Y; Zallo, A; Bagnasco, S; Buzzo, A; Contri, R; Crosetti, G; Fabbricatore, P; Farinon, S; Lo Vetere, M; Macri, M; Monge, M R; Musenich, R; Pallavicini, M; Parodi, R; Passaggio, S; Pastore, F C; Patrignani, C; Pia, M G; Priano, C; Robutti, E; Santroni, A; Morii, M; Bartoldus, R; Dignan, T; Hamilton, R; Mallik, U; Cochran, J; Crawley, H B; Fischer, P A; Lamsa, J; Meyer, W T; Rosenberg, E I; Benkebil, M; Grosdidier, G; Hast, C; Höcker, A; Lacker, H M; LePeltier, V; Lutz, A M; Plaszczynski, S; Schune, M H; Trincaz-Duvoid, S; Valassi, A; Wormser, G; Bionta, R M; Brigljevic, V; Fackler, O; Fujino, D; Lange, D J; Mugge, M; Shi, X; van Bibber, K; Wenaus, T J; Wright, D M; Wuest, C R; Carroll, M; Fry, J R; Gabathuler, E; Gamet, R; George, M; Kay, M; Payne, D J; Sloane, R J; Touramanis, C; Aspinwall, M L; Bowerman, D A; Dauncey, P D; Egede, U; Eschrich, I; Gunawardane, N J; Martin, R; Nash, J A; Sanders, P; Smith, D; Azzopardi, D E; Back, J J; Dixon, P; Harrison, P F; Potter, R J; Shorthouse, H W; Strother, P; Vidal, P B; Williams, M I; Cowan, G; George, S; Green, M G; Kurup, A; Marker, C E; McGrath, P; McMahon, T R; Ricciardi, S; Salvatore, F; Scott, I; Vaitsas, G; Brown, D; Davis, C L; Allison, J; Barlow, R J; Boyd, J T; Forti, A; Fullwood, J; Jackson, F; Lafferty, G D; Savvas, N; Simopoulos, E T; Weatherall, J H; Farbin, A; Jawahery, A; Lillard, V; Olsen, J; Roberts, D A; Schieck, J R; Blaylock, G; Dallapiccola, C; Flood, K T; Hertzbach, S S; Kofler, R; Lin, C S; Moore, T B; Staengle, H; Willocq, S; Wittlin, J; Brau, B; Cowan, R; Sciolla, G; Taylor, F; Yamamoto, R K; Britton, D I; Milek, M; Patel, P M; Trischuk, J; Lanni, F; Palombo, F; Bauer, J M; Booke, M; Cremaldi, L; Eschenburg, V; Kroeger, R; Reidy, J; Sanders, D A; Summers, D J; Martin, J P; Nief, J Y; Seitz, R; Taras, P; Zacek, V; Nicholson, H; Sutton, C S; Cartaro, C; Cavallo, N; De Nardo, G; Fabozzi, F; Gatto, C; Lista, L; Paolucci, P; Piccolo, D; Sciacca, C; LoSecco, J M; Alsmiller, J R; Gabriel, T A; Handler, T; Brau, J; Frey, R; Iwasaki, M; Sinev, N B; Strom, D; Colecchia, F; Dal Corso, F; Dorigo, A; Galeazzi, F; Margoni, M; Michelon, G; Morandin, M; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Torassa, E; Voci, C; Benayoun, M; Briand, H; Chauveau, J; David, P; De La Vaissière, C; Del Buono, L; Hamon, O; Le Diberder, F; Leruste, P; Lory, J; Roos, L; Stark, J; Versillé, S; Manfredi, P F; Re, V; Speziali, V; Frank, E D; Gladney, L; Guo, Q H; Panetta, J H; Angelini, C; Batignani, G; Bettarini, S; Bondioli, M; Carpinelli, M; Forti, F; Giorgi, M A; Lusiani, A; Martinez-Vidal, F; Morganti, M; Neri, N; Paoloni, E; Rama, M; Rizzo, G; Sandrelli, F; Simi, G; Triggiani, G; Walsh, J; Haire, M; Judd, D; Paick, K; Turnbull, L; Wagoner, D E; Albert, J; Bula, C; Lu, C; McDonald, K T; Miftakov, V; Schaffner, S F; Smith, A J; Tumanov, A; Varnes, E W; Cavoto, G; del Re, D; Faccini, R; Ferrarotto, F; Ferroni, F; Fratini, K; Lamanna, E; Leonardi, E; Mazzoni, M A; Morganti, S; Piredda, G; Safai Tehrani, F; Serra, M; Voena, C; Christ, S; Waldi, R; Adye, T; Franek, B; Geddes, N I; Gopal, G P; Xella, S M; Aleksan, R; De Domenico, G; Emery, S; Gaidot, A; Ganzhur, S F; Giraud, P F; Hamel De Monchenault, G; Kozanecki, W; Langer, M; London, G W; Mayer, B; Serfass, B; Vasseur, G; Yeche, C; Zito, M; Copty, N; Purohit, M V; Singh, H; Yumiceva, F X; Adam, I; Anthony, P L; Aston, D; Baird, K; Bartelt, J; Bloom, E; Boyarski, A M; Bulos, F; Calderini, G; Claus, R; Convery, M R; Coupal, D P; Coward, D H; Dorfan, J; Doser, M; Dunwoodie, W; Field, R C; Glanzman, T; Godfrey, G L; Grosso, P; Himel, T; Huffer, M E; Innes, W R; Jessop, C P; Kelsey, M H; Kim, P; Kocian, M L; Langenegger, U; Leith, D W; Luitz, S; Luth, V; Lynch, H L; Manzin, G; Marsiske, H; Menke, S; Messner, R; Moffeit, K C; Mount, R; Muller, D R; O'Grady, C P; Petrak, S; Quinn, H; Ratcliff, B N; Robertson, S H; Rochester, L S; Roodman, A; Schietinger, T; Schindler, R H; Schwiening, J; Serbo, V V; Snyder, A; Soha, A; Spanier, S M; Stahl, A; Stelzer, J; Su, D; Sullivan, M K; Talby, M; Tanaka, H A; Trunov, A; Va'vra, J; Wagner, S R; Weinstein, A J; Wisniewski, W J; Young, C C; Burchat, P R; Cheng, C H; Kirkby, D; Meyer, T I; Roat, C; De Silva, A; Henderson, R; Bugg, W; Cohn, H; Hart, E; Weidemann, A W; Benninger, T; Izen, J M; Kitayama, I; Lou, X C; Turcotte, M; Bianchi, F; Bona, M; Di Girolamo, B; Gamba, D; Smol, A; Zanin, D; Bosisio, L; Della Ricca, G; Lanceri, L; Pompili, A; Poropat, P; Prest, M; Vallazza, E; Vuagnin, G; Panvini, R S; Brown, C M; Kowalewski, R; Roney, J M; Band, H R; Charles, E; Dasu, S; Elmer, P; Hu, H; Johnson, J R; Liu, R; Nielsen, J; Orejudos, W; Pan, Y; Prepost, R; Scott, I J; Sekula, S J; von Wimmersperg-Toeller, J H; Wu, S L; Yu, Z; Zobering, H; Kordich, T M; Neal, H

    2001-10-08

    We have observed the decays B--> phiK and phiK(*) in a sample of over 45 million B mesons collected with the BABAR detector at the PEP-II collider. The measured branching fractions are B(B+--> phiK+) = (7.7(+1.6)(-1.4)+/-0.8)x10(-6), B(B0--> phiK0) = (8.1(+3.1)(-2.5)+/-0.8)x10(-6), B(B+--> phiK(*+)) = (9.7(+4.2)(-3.4)+/-1.7)x10(-6), and B(B0--> phiK(*0)) = (8.7(+2.5)(-2.1)+/-1.1)x10(-6). We also report the upper limit B(B+--> phipi(+))<1.4x10(-6) ( 90% C.L.).

  19. Pipe support

    International Nuclear Information System (INIS)

    Pollono, L.P.

    1979-01-01

    A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems is described. A section of the pipe to be suppported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe

  20. Design and Integrity Evaluation of High-temperature Piping Systems in the STELLA-2 Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok-Kwon; Lee, Hyeong-Yeon; Eoh, JaeHyuk; Kim, Jong-Bum; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ju, Yong-Sun [KOASIS Inc., Daejeon (Korea, Republic of)

    2016-09-15

    In this study, elevated temperature design and integrity evaluation have been conducted using two different piping design codes for the high-temperature piping systems of sodium integral effect test loop for safety simulation and assessment(STELLA-2) being developed by KAERI(Korea Atomic Energy Research Institute). The design code of ASME B31.1 for power piping and French nuclear grade piping design guideline, RCC-MRx RD-3600 were applied, and conservatism of those codes was quantified based on the piping integrity evaluation results. The piping system of Model DHRS, Model IHTS and PSLS are to be installed in STELLA-2. The integrity evaluation results for the three piping systems according to the two design codes showed that integrity of the piping system was confirmed. As a code comparison result, ASME B31.1 was shown to be more conservative for sustained loads while RD-3600 was more conservative for thermal loads compared to B31.1.

  1. Injection of nano-particles in mitigating flow accelerated corrosion (FAC) damage in the secondary system of nuclear power plants (NPPs)

    International Nuclear Information System (INIS)

    Lim, Dong Seok; Ku, Hee Kwon; Cho, Jae Seon

    2015-01-01

    NPPs produces electric energy through phase transition of water. According to this, a piping, which is flow path, integrity is essential for safety functions. Erosion, FAC and fittings are corrosion failure mechanism by increasing service life. Especially, there are 10-kilometers of piping in secondary systems. It needs to estimate FAC and apply periodic management. Iron oxides produced by FAC cause power reduction and Loss Of Coolant Accident (LOCA) will be occurred through the continued piping wall thinning. In this study, corrosion rate of pipe materials with carbon steel(SA106.Gr.B) and low-alloy steel (SA335.P22) was evaluated for pipe configuration and dissolved oxygen concentration on 150 °C, pH 9.5∼10.0 and flow velocity of 5m/s. Temperature of 150°C is well known that causes high FAC rate and pH consider a NPPs in-service condition. Further corrosion rate test was performed to develop FAC reduction technology through Pt-nanoparticle injection. In this study, corrosion rate is evaluated by weight depletion method. The results of material impact assessment show that corrosion rate of carbon steel is more higher than that of low-alloy steel because of Cr content. And also, the results of pipe configuration test show that case with 90° elbow had maximum wall thinning than with 180° horizontal pipe. The dissolved oxygen concentration test shows that low oxygen condition, ≤5 ppb, had high corrosion rate compared to normal condition and the corrosion rate decreased 50% at Pt-nanoparticle injection test on maximum corrosion rate condition compared to maximum wall thinning condition without Pt-nanoparticle injection. In this study, samples provided by each test case had analyzed through SEM-EDX (Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy). Behavior evaluation for oxide film was performed and Electrochemical corrosion potential (ECP) was measured for electrochemistry evaluation. To apply Pt-nanoparticle injection technology on nuclear

  2. Optical pumping of Rb by Ti:Sa laser and high-power laser diode

    Czech Academy of Sciences Publication Activity Database

    Buchta, Zdeněk; Rychnovský, Jan; Lazar, Josef

    2006-01-01

    Roč. 8, č. 1 (2006), s. 350-354 ISSN 1454-4164 R&D Projects: GA AV ČR IAA1065303; GA ČR GA102/04/2109 Institutional research plan: CEZ:AV0Z20650511 Keywords : optical pumping * Ti:Sa laser * laser diode * emission linewidth * spectroscopy * laser frequency stabilization Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.106, year: 2006

  3. An inspection of pipe by snake robot

    Directory of Open Access Journals (Sweden)

    František Trebuňa

    2016-10-01

    Full Text Available The article deals with development and application of snake robot for inspection pipes. The first step involves the introduction of a design of mechanical and electrical parts of the snake robot. Next, the analysis of the robot locomotion is introduced. For the curved pipe, potential field method is used. By this method, the system is able to generate path for the head and rear robot, linking the environment with obstacles, which are represented by the walls of the pipe. Subsequently, the solution of potential field method is used in inverse kinematic model, which respects tasks as obstacle avoidance, joint limit avoidance, and singularity avoidance. Mentioned approach is then tested on snake robot in provisional pipe with rectangular cross section. For this research, software Matlab (2013b is used as the control system in cooperation with the control system of robot, which is based on microcontrollers. By experiments, it is shown that designed robot is able to pass through straight and also curved pipe.

  4. Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 3. Evaluation of potential for pipe breaks

    Energy Technology Data Exchange (ETDEWEB)

    1984-11-01

    The Executive Director for Operations (EDO) in establishing the Piping Review Committee concurred in its overall scope that included an evaluation of the potential for pipe breaks. The Pipe Break Task Group has responded to this directive. This report summarizes a review of regulatory documents and contains the Task Group's recommendations for application of the leak-before-break (LBB) approach to the NRC licensing process. The LBB approach means the application of fracture mechanics technology to demonstrate that high energy fluid piping is very unlikely to experience double-ended ruptures or their equivalent as longitudinal or diagonal splits. The Task Group's reommendations and discussion are founded on current and ongoing NRC staff actions as presented in Section 3.0 of this report. Additional more detailed comments and discussion are presented in Section 5.0 and in Appendices A and B. The obvious issues are the reexamination of the large pipe break criteria and the implications of any changes in the criteria as they influence items such as jet loads and pipe whip. The issues have been considered and the Task Group makes the following recommendations.

  5. Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 3. Evaluation of potential for pipe breaks

    International Nuclear Information System (INIS)

    1984-11-01

    The Executive Director for Operations (EDO) in establishing the Piping Review Committee concurred in its overall scope that included an evaluation of the potential for pipe breaks. The Pipe Break Task Group has responded to this directive. This report summarizes a review of regulatory documents and contains the Task Group's recommendations for application of the leak-before-break (LBB) approach to the NRC licensing process. The LBB approach means the application of fracture mechanics technology to demonstrate that high energy fluid piping is very unlikely to experience double-ended ruptures or their equivalent as longitudinal or diagonal splits. The Task Group's reommendations and discussion are founded on current and ongoing NRC staff actions as presented in Section 3.0 of this report. Additional more detailed comments and discussion are presented in Section 5.0 and in Appendices A and B. The obvious issues are the reexamination of the large pipe break criteria and the implications of any changes in the criteria as they influence items such as jet loads and pipe whip. The issues have been considered and the Task Group makes the following recommendations

  6. Accidents with biological material and immunization against hepatitis B among students from the health area Accidente con material biológico y la vacunación contra la hepatitis B en estudiantes del área de la salud Acidente com material biológico e vacinação contra hepatite B entre graduandos da área da saúde

    Directory of Open Access Journals (Sweden)

    Elucir Gir

    2008-06-01

    relacionados a campañas de vacunación y en especial la vacuna contra hepatitis B.O manuseio de instrumentos perfurocortantes por estudantes da área da saúde é freqüente na atividade acadêmica, o que os expõe ao risco de adquirir infecção. Este estudo teve como objetivo analisar os acidentes com material biológico, ocorridos com alunos de graduação da área da saúde. Dos 170 acidentes registrados, 83 (48,8% ocorreram com alunos do curso de odontologia, 69 (40,6% de medicina, 11 (6,5% de enfermagem e em 6 (3,5% não havia a informação na ficha de atendimento. A maioria (106-62,4% ocorreu com alunos de escolas privadas e 55(32,3% de escolas públicas. Os acidentes percutâneos ocorreram em 133 (78,2% exposições e em apenas 38 (21,3% acidentes a procura pelo atendimento especializado foi imediata. Em 127 (74,7% acidentes o esquema vacinal contra hepatite B estava completo. Assim, torna-se imprescindível que as escolas ofereçam cursos e/ou disciplinas específicas sobre medidas de biossegurança, incluindo aspectos relacionados à vacinação e em especial à vacina contra hepatite B.

  7. Pipe clamp effects on thin-walled pipe design

    International Nuclear Information System (INIS)

    Lindquist, M.R.

    1980-01-01

    Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods to reduce the number of individual clamp locations requiring analysis are described

  8. Grupo PET-Saúde/Vigilância em Saúde do Trabalhador Portuário: vivência compartilhada

    Directory of Open Access Journals (Sweden)

    Maria de Fátima Ferreira Queiróz

    2015-12-01

    Full Text Available Trata-se de um relato de vivência compartilhada do Grupo PET-Saúde/ Vigilância em Saúde do Trabalhador Portuário, da Universidade Federal de São Paulo – Unifesp e o Centro de Referência em Saúde do Trabalhador – CEREST, de Santos, SP. O objetivo é descrever a experiência desse grupo tutorial e sua contribuição para o fortalecimento de ações de vigilância em saúde do trabalhador de Santos. O trabalho portuário é a temática do PET-Saúde por sua importância no cenário nacional e por sofrer transformações que geram fatores de agravos à saúde dos trabalhadores. As ações são desenvolvidas englobando o CEREST, os serviços da rede de saúde de Santos e a comunidade portuária santista. Observa-se que os participantes têm compartilhado conhecimento teórico e prático profissional, contribuindo nas ações dos trabalhadores do CEREST e apontando na direção de aproximação com a rede básica de atenção à saúde.

  9. Saúde Ambiental e Atenção Primária à Saúde nos microterritórios: a taxa de mortalidade infantil para subsidiar a atuação da equipe de saúde

    Directory of Open Access Journals (Sweden)

    Herling Gregorio Aguilar Alonzo

    2013-06-01

    Full Text Available Nos últimos 20 anos, o Sistema Único de Saúde no Brasil vem avançando no aprimoramento da atenção primaria e da vigilância em saúde ambiental. No País, também, melhorou a cobertura do saneamento básico. Mas existem iniquidades macrorregionais e são escassas as informações sobre os microterritórios, onde as ações básicas de saúde se concretizam. Descrever a influência das coberturas do sistema de abastecimento de água (SAA, esgotamento sanitário (ES e coleta de resíduos sólidos domiciliares (CRSD na taxa mortalidade infantil (TMI nas áreas de abrangência das unidades básicas de saúde (UBS do Distrito de Saúde Noroeste de Campinas-SP. Foi conduzido estudo ecológico com dados secundários referentes a 2000. As coberturas nas oito UBS: do SAA variou entre 96,3 %, de Valença, e 99,9 % de Integração; de ES entre 67 %, de Ipaussurama e 99,8 % de Integração; da CRSD entre 95,8 % de Florence e 99,9 % de Perseu e Integração. A TMI variou entre 5,5 ‰, na UBS Perseu e 22,9 ‰ Floresta. Observou-se que existe relação inversa, quanto maior a cobertura do SAA (R2=0,73, de ES (R2=0,78 e da CRSD (R2= 0,95 menor a TMI nas UBS. Além de outros fatores, o saneamento básico determina o processo saúde doença da população e conforme os achados, existem iniquidades também nos microterritórios de abrangência das UBS que devem ser consideradas pelos gestores e profissionais de saúde, principalmente, da atenção primária na pactuação das prioridades, ações e metas para atenção integral e vigilância em saúde e atuação intersetorial.

  10. Non-metallic structural wrap systems for pipe

    International Nuclear Information System (INIS)

    Walker, R.H.; Wesley Rowley, C.

    2001-01-01

    The use of thermoplastics and reinforcing fiber has been a long-term application of non-metallic material for structural applications. With the advent of specialized epoxies and carbon reinforcing fiber, structural strength approaching and surpassing steel has been used in a wide variety of applications, including nuclear power plants. One of those applications is a NSWS for pipe and other structural members. The NSWS is system of integrating epoxies with reinforcing fiber in a wrapped geometrical configuration. This paper specifically addresses the repair of degraded pipe in heat removal systems used in nuclear power plants, which is typically caused by corrosion, erosion, or abrasion. Loss of structural material leads to leaks, which can be arrested by a NSWS for the pipe. The technical aspects of using thermoplastics to structurally improve degraded pipe in nuclear power plants has been addressed in the ASME B and PV Code Case N-589. Using the fundamentals described in that Code Case, this paper shows how this technology can be extended to pipe repair from the outside. This NSWS has already been used extensively in non-nuclear applications and in one nuclear application. The cost to apply this NSWS is typically substantially less than replacing the pipe and may be technically superior to replacing the pipe. (author)

  11. Type B Investigation Report for 241-SY-101 Pump Start and 241-C-106 Pit Cleanout

    Energy Technology Data Exchange (ETDEWEB)

    Ewalt, J.R.

    1993-09-01

    In accordance with the direction of the Department of Energy (DOE) Manager, Richland Operations Office, a Type ``B`` investigation in accordance with the DOE Order 5484.1, Environmental Protection, Safety and Health Protection Information Reporting Requirements, has been conducted. The scope of the investigation included two events: The ``Inadvertent Mixer Pump Operation at 241-SY-101`` (RL-WHC-TANK FARM-1993-069); ``Inadequate Work Control Results in Personnel Skin Contamination at 241-C-106, Pit B`` (RL-WHC-TANK FARM-1993-071) events. Additionally, at the request of the President of the WHC, a broader investigation into Waste Tank Farm ``safety practices`` and ``Conduct of Operations`` was also conducted. The review was focused on (1) WHC organizations performing operations, maintenance, and radiological safety tasks; and (2) KEH organizations performing major maintenance tasks.

  12. Failure and factors of safety in piping system design

    International Nuclear Information System (INIS)

    Antaki, G.A.

    1993-01-01

    An important body of test and performance data on the behavior of piping systems has led to an ongoing reassessment of the code stress allowables and their safety margin. The codes stress allowables, and their factors of safety, are developed from limits on the incipient yield (for ductile materials), or incipient rupture (for brittle materials), of a test specimen loaded in simple tension. In this paper, we examine the failure theories introduced in the B31 and ASME III codes for piping and their inherent approximations compared to textbook failure theories. We summarize the evolution of factors of safety in ASME and B31 and point out that, for piping systems, it is appropriate to reconsider the concept and definition of factors of safety

  13. Association of TMEM106B gene polymorphism with age at onset in granulin mutation carriers and plasma granulin protein levels.

    Science.gov (United States)

    Cruchaga, Carlos; Graff, Caroline; Chiang, Huei-Hsin; Wang, Jun; Hinrichs, Anthony L; Spiegel, Noah; Bertelsen, Sarah; Mayo, Kevin; Norton, Joanne B; Morris, John C; Goate, Alison

    2011-05-01

    To test whether rs1990622 (TMEM106B) is associated with age at onset (AAO) in granulin (GRN) mutation carriers and with plasma GRN levels in mutation carriers and healthy, elderly individuals. Rs1990622 (TMEM106B) was identified as a risk factor for frontotemporal lobar degeneration with TAR DNA-binding protein inclusions (FTLD-TDP) in a recent genome-wide association. Rs1990622 was genotyped in GRN mutation carriers and tested for association with AAO using the Kaplan-Meier method and a Cox proportional hazards model. Alzheimer's Disease Research Center. Subjects  We analyzed 50 affected and unaffected GRN mutation carriers from 4 previously reported FTLD-TDP families (HDDD1, FD1, HDDD2, and the Karolinska family). The GRN plasma levels were also measured in 73 healthy, elderly individuals. Age at onset and GRN plasma levels. The risk allele of rs1990622 was associated with a mean decrease of the AAO of 13 years (P = 9.9 × 10(-7)) and with lower plasma GRN levels in both healthy older adults (P = 4 × 10(-4)) and GRN mutation carriers (P = .0027). Analysis of the HapMap database identified a nonsynonymous single-nucleotide polymorphism rs3173615 (T185S) in perfect linkage disequilibrium with rs1990622. The association of rs1990622 with AAO explains, in part, the wide range in the AAO of disease among GRN mutation carriers. We hypothesize that rs1990622 or another variant in linkage disequilibrium could act in a manner similar to APOE in Alzheimer disease, increasing risk for disease in the general population and modifying AAO in mutation carriers. Our results also suggest that genetic variation in TMEM106B may influence risk for FTLD-TDP by modulating secreted levels of GRN.

  14. Investigation of micro-gravity effects on heat pipe thermal performance and working fluid behavior, phase B

    Science.gov (United States)

    Gier, K. D.; Smith, M. O.

    1990-01-01

    The purpose of this experiment is to develop an in-depth understanding of the behavior of heat pipes in space. Both fixed conductance heat pipes (FCHPs) with axial grooves and variable conductance heat pipes (VCHPs) with porous wicks will be investigated. This understanding will be applied to the development of improved performance heat pipes subjected to various accelerations in space, including those encountered on a lunar base or Mars mission. More efficient, reliable, and lighter weight spacecraft thermal control systems should result from these investigations.

  15. A fracture mechanics assessment of surface cracks existing in protective layers of multi-layer composite pipes

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Náhlík, Luboš; Šestáková, Lucie; Ševčík, Martin; Knésl, Zdeněk; Nezbedová, E.

    2010-01-01

    Roč. 92, č. 5 (2010), s. 1120-1125 ISSN 0263-8223 R&D Projects: GA ČR GA106/09/0279 Institutional research plan: CEZ:AV0Z20410507 Keywords : Protective layers * Multi-layer pipes damage * Fracture mechanics * Bi-material interface * Generalized stress intensity factor Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.028, year: 2010

  16. Failure rates in piping manufactured to different standards

    International Nuclear Information System (INIS)

    Barnes, R.W.; Cooper, G.D.

    1995-11-01

    Most non-nuclear process piping systems in Canada and the United States are constructed to the requirements of the piping codes of the American Society of Mechanical Engineers (ASME B31.1 and B31.3). Section III of the ASME Boiler and Pressure Vessel Code, has additional requirements for piping that are expected to provide further assurance of pressure boundary integrity. This project attempted to determine if the additional requirements of Section III were beneficial in preventing failure of the pressure boundary. The approach taken in the study was to determine the causes of failure of non-nuclear piping subjected to service similar to that experienced by piping in CANDU nuclear power plants. The study examined information on carbon steel piping systems filled with water/steam which operate up to a maximum temperature of 600 F and a maximum pressure of 1600 psi. The failure mechanisms were identified and analysed to determine whether application of the requirements of Section III would have prevented the failure. Through a process of interviews and literature search, 186 failures were identified and assembled into a reference database. Many of the records were incomplete; therefore, the reference database was trimmed to include a subset of 65 failure points supported by complete data. This subset formed the basis for this study. The results from the study of other databases assembled for similar purposes were reviewed and compared to the conclusions reached in this study. These reviews confirmed the conclusions reached in this study. (author). 48 refs., 20 tabs

  17. CD36 participates in PrP(106-126-induced activation of microglia.

    Directory of Open Access Journals (Sweden)

    Mohammed Kouadir

    Full Text Available Microglial activation is a characteristic feature of the pathogenesis of prion diseases. The molecular mechanisms that underlie prion-induced microglial activation are not very well understood. In the present study, we investigated the role of the class B scavenger receptor CD36 in microglial activation induced by neurotoxic prion protein (PrP fragment 106-126 (PrP(106-126. We first examined the time course of CD36 mRNA expression upon exposure to PrP(106-126 in BV2 microglia. We then analyzed different parameters of microglial activation in PrP(106-126-treated cells in the presence or not of anti-CD36 monoclonal antibody (mAb. The cells were first incubated for 1 h with CD36 monoclonal antibody to block the CD36 receptor, and were then treated with neurotoxic prion peptides PrP(106-126. The results showed that PrP(106-126 treatment led to a rapid yet transitory increase in the mRNA expression of CD36, upregulated mRNA and protein levels of proinflammatory cytokines (IL-1β, IL-6 and TNF-α, increased iNOS expression and nitric oxide (NO production, stimulated the activation of NF-κB and caspase-1, and elevated Fyn activity. The blockade of CD36 had no effect on PrP(106-126-stimulated NF-κB activation and TNF-α protein release, abrogated the PrP(106-126-induced iNOS stimulation, downregulated IL-1β and IL-6 expression at both mRNA and protein levels as well as TNF-α mRNA expression, decreased NO production and Fyn phosphorylation, reduced caspase-1 cleavage induced by moderate PrP(106-126-treatment, but had no effect on caspase-1 activation after treatment with a high concentration of PrP(106-126. Together, these results suggest that CD36 is involved in PrP(106-126-induced microglial activation and that the participation of CD36 in the interaction between PrP(106-126 and microglia may be mediated by Src tyrosine kinases. Our findings provide new insights into the mechanisms underlying the activation of microglia by neurotoxic prion peptides

  18. Characterization of Anisotropic Behavior for High Grade Pipes

    Science.gov (United States)

    Yang, Kun; Huo, Chunyong; Ji, Lingkang; Li, Yang; Zhang, Jiming; Ma, Qiurong

    With the developing requirement of nature gas, the property needs of steel for pipe line are higher and higher, especially in strength and toughness. It is necessary to improve the steel grade in order to ensure economic demand and safety. However, with the rise of steel grade, the differences on properties in different orientations (anisotropic behaviors) become more and more obvious after the process of hot rolling, which may affect the prediction of fracture for the pipes seriously (Thinking of isotropic mechanical properties for material in traditional predict way). In order to get the reason for anisotropic mechanics, a series of tests are carried out for high grade steel pipes, including not only mechanical properties but also microstructures. Result indicates that there are obviously anisotropic behaviors for high grade steel pipes in two orientations (rolling orientation and transverse orientation). Strength is better in T orientation because Rm is higher and Rt 0.5 rises more in T orientation, and toughness is better in L orientation because of the higher Akv and SA in L orientation under a same temperature. Banded structures are formed in T orientation, and the spatial distribution of inclusion and precipitated phases are different in T, L and S orientation. The anisotropic arrangement for the matrix in space (banded structures), which is formed after the process of hot rolling, may affect the mechanical properties in different orientation. Moreover, the elasticity modulus of particles is different from the elasticity modulus of matrix, deformation between particles and matrix may cause stress concentration, and damage forms in this place. Because of the different distribution of particles in space, the level of damage is anisotropic in different orientations, and the anisotropic mechanical properties occur finally. Therefore, the anisotropic mechanical properties are determined by the anisotropic microstructures, both the anisotropic of matrix and the

  19. 24 CFR 1000.106 - What families receiving assistance under title II of NAHASDA require HUD approval?

    Science.gov (United States)

    2010-04-01

    ... under title II of NAHASDA require HUD approval? 1000.106 Section 1000.106 Housing and Urban Development... Housing Activities § 1000.106 What families receiving assistance under title II of NAHASDA require HUD... in §§ 1000.108 and 1000.110. (b) Assistance under section 201(b)(3) of NAHASDA for non-Indian...

  20. Experimental investigation on Heat Transfer Performance of Annular Flow Path Heat Pipe

    International Nuclear Information System (INIS)

    Kim, In Guk; Kim, Kyung Mo; Jeong, Yeong Shin; Bang, In Cheol

    2015-01-01

    Mochizuki et al. was suggested the passive cooling system to spent nuclear fuel pool. Detail analysis of various heat pipe design cases was studied to determine the heat pipes cooling performance. Wang et al. suggested the concept PRHRS of MSR using sodium heat pipes, and the transient performance of high temperature sodium heat pipe was numerically simulated in the case of MSR accident. The meltdown at the Fukushima Daiichi nuclear power plants alarmed to the dangers of station blackout (SBO) accident. After the SBO accident, passive decay heat removal systems have been investigated to prevent the severe accidents. Mochizuki et al. suggested the heat pipes cooling system using loop heat pipes for decay heat removal cooling and analysis of heat pipe thermal resistance for boiling water reactor (BWR). The decay heat removal systems for pressurized water reactor (PWR) were suggested using natural convection mechanisms and modification of PWR design. Our group suggested the concept of a hybrid heat pipe with control rod as Passive IN-core Cooling System (PINCs) for decay heat removal for advanced nuclear power plant. Hybrid heat pipe is the combination of the heat pipe and control rod. In the present research, the main objective is to investigate the effect of the inner structure to the heat transfer performance of heat pipe containing neutron absorber material, B 4 C. The main objective is to investigate the effect of the inner structure in heat pipe to the heat transfer performance with annular flow path. ABS pellet was used instead of B 4 C pellet as cylindrical structures. The thermal performances of each heat pipes were measured experimentally. Among them, concentric heat pipe showed the best performance compared with others. 1. Annular evaporation section heat pipe and annular flow path heat pipe showed heat transfer degradation. 2. AHP also had annular vapor space and contact cooling surface per unit volume of vapor was increased. Heat transfer coefficient of

  1. Suppression or knockout of SaF/SaM overcomes the Sa-mediated hybrid male sterility in rice

    Institute of Scientific and Technical Information of China (English)

    Yongyao Xie; Baixiao Niu; Yunming Long; Gousi Li; Jintao Tang; Yaling Zhang; Ding Ren; Yao-Guang Liu; Letian Chen

    2017-01-01

    Hybrids between the indica and japonica subspecies of rice (Oryza sativa) are usually sterile, which hinders utilization of heterosis in the inter-subspecific hybrid breeding. The complex locus Sa comprises two adjacently located genes, SaF and SaM, which interact to cause abortion of pollen grains carrying the japonica allele in japonica-indica hybrids. Here we showed that silencing of SaF or SaM by RNA interference restored male fertility in indica-japonica hybrids with heterozygous Sa. We further used clustered regularly interspaced short palindromic repeats (CRISPR)/Cas9-based genome editing to knockout the SaF and SaM alleles, respectively, of an indica rice line to create hybrid-compatible lines. The resultant artificial neutral alleles did not affect pollen viability and other agricultural traits, but did break down the reproductive barrier in the hybrids. We found that some rice lines have natural neutral allele Sa-n, which was compatible with the typical japonica or indica Sa alleles in hybrids. Our results demonstrate that SaF and SaM are required for hybrid male sterility, but are not essential for pollen development. This study provides effective approaches for the generation of hybrid-compatible lines by knocking out the Sa locus or using the natural Sa-n allele to overcome hybrid male sterility in rice breeding.

  2. Bench-scale crossflow filtration of Hanford tank C-106, C-107, B-110, and U-110 sludge slurries

    International Nuclear Information System (INIS)

    Geeting, J.G.H.; Reynolds, B.A.

    1997-09-01

    Pacific Northwest National Laboratory has a bench-scale crossflow filter installed in a shielded hot cell for testing radioactive feeds. During FY97 experiments were conducted on slurries from radioactive Hanford waste from tanks C-106, C-107, B-110, and U-110. Each tank was tested at three slurry concentrations (8, 1.5, and 0.05 wt% solids). A two-parameter central composite design which tested transmembrane pressure from 5 to 40 psig and axial velocity from 3 to 9 ft/s was used for all feeds. Crossflow filtration was found to remove solids effectively, as judged by filtrate clarity and radiochemical analysis. If the filtrates from these tests were immobilized in a glass matrix, the resulting transuranic and ( 90 Sr) activity would not breach low activity waste glass limits of 100nCi/g (TRU) and 20 μCi/ml ( 90 Sr). Two exceptions were the transuranic activity in filtrates from processing 1.5 and 8 wt% C-106 tank waste. Subsequent analyses indicated that the source of the TRU activity in the filtrate was most likely due to soluble activity, but obviously proved ineffective at removing the soluble plutonium species. Re-testing of the C-106 supported this hypothesis. These data suggest the need to control carbonate and pH when processing tank wastes for immobilization

  3. Regulatory analysis for the resolution of Generic Safety Issue 106: Piping and the use of highly combustible gases in vital areas

    International Nuclear Information System (INIS)

    Graves, C.C.

    1993-06-01

    Highly combustible gases such as hydrogen, propane, and acetylene are used at all nuclear power plants. Hydrogen is of particular importance because it is stored in large quantities and is distributed and used continuously in buildings containing safety-related equipment. Large hydrogen releases at the hydrogen storage facilities or in these buildings could lead to fires or explosions that might result in loss of safety-related equipment. This report gives the regulatory analysis for the resolution of Generic Safety Issue 106, open-quotes Piping and the Use of Highly Combustible Gases in Vital Areas.close quotes Scoping analyses showed that the risk associated with the storage and distribution of hydrogen for cooling electric generators at boiling-water reactors (BWRs), the off-gas system at BWRs, the waste gas system at pressurized-water reactors (PWRs), and station battery rooms and portable bottles of combustible gas used for maintenance at PWRs and BWRs is small. On the basis of generic evaluations, the NRC staff has concluded that several possible methods to reduce risk could provide cost-effective safety benefits at some plants. However, in view of the observed large differences in plant-specific characteristics affecting the risk associated with the use of hydrogen, and the marginal generic safety benefit that can be achieved in a cost-effective manner, it is recommended that this generic issue be resolved simply by making these results available in a generic letter. This information may help licensees in their plant evaluations recommended by Generic Letter 88-20, Supplement 4, open-quotes Individual Plant Examination of External Events for Severe Accident Vulnerabilities,close quotes June 28, 1991

  4. Suppression or knockout of SaF/SaM overcomes the Sa-mediated hybrid male sterility in rice.

    Science.gov (United States)

    Xie, Yongyao; Niu, Baixiao; Long, Yunming; Li, Gousi; Tang, Jintao; Zhang, Yaling; Ren, Ding; Liu, Yao-Guang; Chen, Letian

    2017-09-01

    Hybrids between the indica and japonica subspecies of rice (Oryza sativa) are usually sterile, which hinders utilization of heterosis in the inter-subspecific hybrid breeding. The complex locus Sa comprises two adjacently located genes, SaF and SaM, which interact to cause abortion of pollen grains carrying the japonica allele in japonica-indica hybrids. Here we showed that silencing of SaF or SaM by RNA interference restored male fertility in indica-japonica hybrids with heterozygous Sa. We further used clustered regularly interspaced short palindromic repeats (CRISPR)/Cas9-based genome editing to knockout the SaF and SaM alleles, respectively, of an indica rice line to create hybrid-compatible lines. The resultant artificial neutral alleles did not affect pollen viability and other agricultural traits, but did break down the reproductive barrier in the hybrids. We found that some rice lines have natural neutral allele Sa-n, which was compatible with the typical japonica or indica Sa alleles in hybrids. Our results demonstrate that SaF and SaM are required for hybrid male sterility, but are not essential for pollen development. This study provides effective approaches for the generation of hybrid-compatible lines by knocking out the Sa locus or using the natural Sa-n allele to overcome hybrid male sterility in rice breeding. © 2017 The Authors. Bioelectromagnetics published by Wiley Periodicals, Inc. © 2017 Institute of Botany, Chinese Academy of Sciences.

  5. 76 FR 39852 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-07-07

    ..., or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  6. 77 FR 13079 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-03-05

    ... produced, or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  7. HPFRCC - Extruded Pipes

    DEFF Research Database (Denmark)

    Stang, Henrik; Pedersen, Carsten

    1996-01-01

    The present paper gives an overview of the research onHigh Performance Fiber Reinforced Cementitious Composite -- HPFRCC --pipes recently carried out at Department of Structural Engineering, Technical University of Denmark. The project combines material development, processing technique development......-w$ relationship is presented. Structural development involved definition of a new type of semi-flexiblecement based pipe, i.e. a cement based pipe characterized by the fact that the soil-pipe interaction related to pipe deformation is an importantcontribution to the in-situ load carrying capacity of the pipe...

  8. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    International Nuclear Information System (INIS)

    Jang, Youn Young; Huh, Nam Su; Jeong, Jae Uk

    2016-01-01

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows

  9. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Youn Young; Huh, Nam Su [Dept. of Mechanical System Design Engineering, Seoul National Univ. of Science and Technology, Seoul (Korea, Republic of); Jeong, Jae Uk [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of)

    2016-09-15

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows.

  10. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.

    1985-01-01

    Studies are being conducted at the Idaho National Engineering Laboratory to determine whether an increase in the damping values used in seismic structural analyses of nuclear piping systems is justified. Increasing the allowable damping would allow fewer piping supports which could lead to safer, more reliable, and less costly piping systems. Test data from availble literature were examined to determine the important parameters contributing to piping system damping, and each was investigated in separate-effects tests. From the combined results a world pipe damping data bank was established and multiple regression analyses performed to assess the relative contributions of the various parameters. The program is being extended to determine damping applicable to higher frequency (33 to 100 Hz) fluid-induced loadings. The goals of the program are to establish a methodology for predicting piping system damping and to recommend revised guidelines for the damping values to be included in analyses

  11. Design Evaluation of a Piping System in the SELFA Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok-Kwon; Jo, Young-Chul; Lee, Hyeong-Yeon; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this study, design evaluations on the SELFA piping system has been conducted according to the ASME B31.1 and RCC-MRx RD-3600. The conservatism of the two codes was quantified based on the evaluation results. It was shown that B31.1 was more conservative for the sustained loads while less conservative for thermal expansion loads when compare with those of RD-3600. However, all the evaluation results according to the two codes were within the code allowables. There are two main piping systems in the SELFA test loop. In this study, the integrity of the SELFA piping system has been evaluated according to the two design-by-rule (DBR) codes of ASME B31.1 and RCC-MRx RD-3600. B31.1 is an industry design code for power piping while RD-3600 is a class 3 nuclear DBR code. The conservatism of the two codes was quantified based on the evaluation results as per the two DBR codes. The sodium test facility of the SELFA is under construction at KAERI for the investigation of thermo-hydraulic behavior of finned-tube sodium-to-air heat exchanger.

  12. Pipe inspection using the pipe crawler. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned

  13. Pipe inspection using the pipe crawler. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned.

  14. Corrosion monitoring of insulated pipe using radiographic technique

    International Nuclear Information System (INIS)

    Azali Muhammad; Abd Aziz Mohamed; Abd Razak Hamzah; Mohd Pauzi Ismail; Abd Nassir Ibrahim; Shaharudin Sayuti; Shukri Ahmad

    2001-01-01

    In petrochemical and power plants, detection of corrosion and evaluation of deposit in insulated pipes using radiographic technique are considered as very challenging tasks. In general this degradation problem is attributed to water condensation. It causes the formation of deposit and scale inside the pipe, as well as between the insulation and pipe in cold temperature pipes. On the other hand, for hot temperature pipes the main problem is mainly due to corrosion/erosion attack inside the pipe. In the study of corrosion in pipelines, one of the most important parameters to be monitored and measured is he wall thickness. Currently, most pipeline corrosion monitoring and evaluation for both insulated and non-insulated pipes is performed using an ultrasonic method. The most common technique is that based on the A-Scan, using either a normal flaw detector or some form of dedicated equipment. However, with recent development of ultrasonic technology, more advance method, namely B-Scan and C-scan techniques are also available. The most notable disadvantage of using this method is that the insulation covering the pipe has to be removed before the inspection can be carried out and this is considered as not so cost effective. Due to this reason, the possibility of employing other alternative NDT method, namely radiographic testing method was studied. The technique used in this studied are known as tangential technique. In this study it was found that the result found using tangential technique is consistent with the actual thickness of the pipe. Result of this study is presented and discussed in this paper. (Author)

  15. Contribuições do PET-Saúde/Redes de Atenção Psicossocial à Saúde da Família

    Directory of Open Access Journals (Sweden)

    Larissa de Almeida Rézio

    2015-12-01

    Full Text Available O estudo objetivou analisar as contribuições do Programa de Educação pelo Trabalho para a Saúde – PET-Saúde/Redes de Atenção Psicossocial à Saúde - a uma unidade de Estratégia de Saúde da Família em Cuiabá, Mato Grosso, Brasil. Trata-se de um estudo descritivo, com abordagem qualitativa, utilizando entrevista com cinco profissionais de saúde e dois acadêmicos bolsistas e registros de atividades realizadas no serviço. À luz da análise de conteúdo temática, sistematizamos quatro subtemas: “articulação da rede”; “qualificação da assistência à saúde mental”, “melhora do conhecimento dos profissionais” e “superação de estigmas sobre o paciente em sofrimento psíquico”. Houve sensibilização dos profissionais e bolsistas sobre a importância do acompanhamento das pessoas com sofrimento mental na atenção básica, em articulação com serviços de saúde mental.

  16. ANSPipe: An IBM-PC interactive code for pipe-break assessment

    International Nuclear Information System (INIS)

    Fullwood, R.R.; Harrington, M.

    1988-01-01

    The advanced neutron source (ANS) being designed at Oak Ridge National Laboratory will be the world's highest flux neutron source and best facility for associated basic and applied research. The ANSPipe code was written as an aid for the piping configuration and material selection to enhance safety and availability. The primary calculation is based on the Thomas mode. which models pipe leak or break probabilities as proportional to the length of the segment and diameter and the inverse square of the wall thickness. This scaling, based on experience, is adjusted for radiation effects, using the Regulatory Guide 1.99 model, and for cyclic fatigue, stress corrosion, and inspection, using adaptations form the PRAISE-B code. The key to an ANSPipe analysis is the definition of the pipe segments. A pipe segment is defined as a length of pipe in which all the parameters affecting the pipe are constant or reasonably so. Thus, a segment would be a length of pipe of constant diameter, thickness, material type, internal pressure, flux distribution, stress, and submergence or nonsubmergence

  17. Pipe connector

    International Nuclear Information System (INIS)

    Sullivan, T.E.; Pardini, J.A.

    1978-01-01

    A safety test facility for testing sodium-cooled nuclear reactor components includes a reactor vessel and a heat exchanger submerged in sodium in the tank. The reactor vessel and heat exchanger are connected by an expansion/deflection pipe coupling comprising a pair of coaxially and slidably engaged tubular elements having radially enlarged opposed end portions of which at least a part is of spherical contour adapted to engage conical sockets in the ends of pipes leading out of the reactor vessel and in to the heat exchanger. A spring surrounding the pipe coupling urges the end portions apart and into engagement with the spherical sockets. Since the pipe coupling is submerged in liquid a limited amount of leakage of sodium from the pipe can be tolerated

  18. Effect of cross section on collapse load in pipe bends subjected to in ...

    African Journals Online (AJOL)

    user

    Also various researchers have estimated the plastic loads of pipe bends with cracks (Hong et al, ... In reality, the pipe bend exists with shape imperfections namely ovality and ... C t. −. = ×. (3). 3. Finite element limit analysis. Figure 1. Pipe bend with ..... Chattopadhyay J., Natahani D. K., Dutta B. K. and Kushwaha H. S. 2000.

  19. Design evaluation on sodium piping system and comparison of the design codes

    International Nuclear Information System (INIS)

    Lee, Dong Won; Jeong, Ji Young; Lee, Yong Bum; Lee, Hyeong Yeon

    2015-01-01

    A large-scale sodium test loop of STELLA-1 (Sodium integral effect test loop for safety simulation and assessment) with two main piping systems has been installed at KAERI. In this study, design evaluations on the main sodium piping systems in STELLA-1 have been conducted according to the DBR (design by rule) codes of the ASME B31.1 and RCC-MRx RB-3600. In addition, design evaluations according to the DBA (design by analysis) code of the ASME Section III Subsection NB-3200 have been conducted. The evaluation results for the present piping systems showed that results from the DBR codes were more conservative than those from the DBA code, and among the DBR codes, the non-nuclear code of the ASME B31.1 was more conservative than the French nuclear DBR code of the RCC-MRx RB-3600. The conservatism on the DBR codes of the ASME B31.1 and RCC-MRx RB-3600 was quantified based on the present sodium piping analyses.

  20. Design evaluation on sodium piping system and comparison of the design codes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Won; Jeong, Ji Young; Lee, Yong Bum; Lee, Hyeong Yeon [KAERI, Daejeon (Korea, Republic of)

    2015-03-15

    A large-scale sodium test loop of STELLA-1 (Sodium integral effect test loop for safety simulation and assessment) with two main piping systems has been installed at KAERI. In this study, design evaluations on the main sodium piping systems in STELLA-1 have been conducted according to the DBR (design by rule) codes of the ASME B31.1 and RCC-MRx RB-3600. In addition, design evaluations according to the DBA (design by analysis) code of the ASME Section III Subsection NB-3200 have been conducted. The evaluation results for the present piping systems showed that results from the DBR codes were more conservative than those from the DBA code, and among the DBR codes, the non-nuclear code of the ASME B31.1 was more conservative than the French nuclear DBR code of the RCC-MRx RB-3600. The conservatism on the DBR codes of the ASME B31.1 and RCC-MRx RB-3600 was quantified based on the present sodium piping analyses.

  1. 0(gs)+ -->2(1)+ transition strengths in 106Sn and 108Sn.

    Science.gov (United States)

    Ekström, A; Cederkäll, J; Fahlander, C; Hjorth-Jensen, M; Ames, F; Butler, P A; Davinson, T; Eberth, J; Fincke, F; Görgen, A; Górska, M; Habs, D; Hurst, A M; Huyse, M; Ivanov, O; Iwanicki, J; Kester, O; Köster, U; Marsh, B A; Mierzejewski, J; Reiter, P; Scheit, H; Schwalm, D; Siem, S; Sletten, G; Stefanescu, I; Tveten, G M; Van de Walle, J; Van Duppen, P; Voulot, D; Warr, N; Weisshaar, D; Wenander, F; Zielińska, M

    2008-07-04

    The reduced transition probabilities, B(E2; 0(gs)+ -->2(1)+), have been measured in the radioactive isotopes (108,106)Sn using subbarrier Coulomb excitation at the REX-ISOLDE facility at CERN. Deexcitation gamma rays were detected by the highly segmented MINIBALL Ge-detector array. The results, B(E2;0(gs)+ -->2(1)+)=0.222(19)e2b2 for 108Sn and B(E2; 0(gs)+-->2(1)+)=0.195(39)e2b2 for 106Sn were determined relative to a stable 58Ni target. The resulting B(E2) values are approximately 30% larger than shell-model predictions and deviate from the generalized seniority model. This experimental result may point towards a weakening of the N=Z=50 shell closure.

  2. Critical care admission of South African (SA) surgical patients ...

    African Journals Online (AJOL)

    Critical care admission of South African (SA) surgical patients: Results of the SA Surgical Outcomes Study. D.L. Skinner, K de Vasconcellos, R Wise, T.M. Esterhuizen, C Fourie, A Goolam Mahomed, P.D. Gopalan, I Joubert, H Kluyts, L.R. Mathivha, B Mrara, J.P. Pretorius, G Richards, O Smith, M.G.L. Spruyt, R.M. Pearse, ...

  3. As invasões bárbaras do Brasil e do Canadá (Quebec) : Sistema Público de Saúde não funciona

    OpenAIRE

    Charmain Levy Levy; Paula Raquel Dos Santos

    2015-01-01

    Resumo : Refletir sobre a funcionalidade das novas vidas diante dos inúmeros cenários e desafios que são oferecidos ao longo do cotidiano, está e a proposta deste texto. As invasões bárbaras que sucedem ao longo da história passam pelos navegantes e aportam na corrupção e no cativeiro da qualidade de vida de uma liberdade prometida. A promoção da saúde e o eixo norteador deste dialogo com referência sobre os sistemas de saúde do Brasil e do Canada. O objeto de intercepção e a universalidade e...

  4. Psicologia clínica existencialista na atenção básica à saúde: um relato de atuação

    OpenAIRE

    Pretto, Zuleica; Langaro, Fabíola; Santos, Geórgia Bunn

    2009-01-01

    A proposta deste artigo é compartilhar uma experiência de intervenção em Psicologia clínica a partir da abordagem existencialista de Jean-Paul Sartre, realizada em uma clínica integrada de atenção básica à saúde vinculada ao Sistema Único de Saúde (SUS), na Grande Florianópolis. O objetivo do atendimento psicológico é criar condições, junto aos sujeitos, para que sejam capazes de superar dificuldades, e auxiliálos a reconstruir seus projetos de ser. A demanda da clínica é diversificada - cria...

  5. Saúde Mental no contexto da atenção básica: potencialidades, limitações, desafios do Programa Saúde da Família

    Directory of Open Access Journals (Sweden)

    Denize Bouttelet Munari

    2008-09-01

    Full Text Available Esse estudo destaca as possibilidades da inclusão da atenção em saúde mental no Programa de Saúde da Família (PSF. O objetivo foi analisar na literatura nacional as possibilidades, limites e desafios dos profissionais do PSF no enfrentamento das questões concernentes à prática. Revisão de literatura realizada em agosto/2007, na Biblioteca Virtual em Saúde, sendo acessadas bases LILACS e SciELO. A busca foi realizada por meio dos descritores “saúde mental”, “família”, e “programa saúde da família”, recuperando apenas artigos publicados em periódicos disponíveis nessas bases entre 1997 e 2007. Identificamos 155 títulos inicialmente que, ao serem analisados possibilitou seleção de 50 artigos (30 LILACS e 20 SciELO. Esse exercício levou a organização do material em dois pontos de convergência: 1. Programa Saúde da Família e a Reabilitação Psicossocial: o que há de comum? 2. Do descompasso aos vôos possíveis: limites, contradições, impasses e possibilidades na atenção em saúde mental no PSF. Concluímos que embora haja tendência de expansão da produção do conhecimento sobre a temática ainda é necessário investimento em iniciativas de superação do modelo assistência, que de fato tenha impacto na prática assistencial.

  6. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.; Arendts, J.G.

    1984-01-01

    A program has been developed to assess the available piping damping data, to generate additional data and conduct seperate effects tests, and to establish a plan for reporting and storing future test results into a data bank. This effort is providing some of the basis for developing higher allowable damping values for piping seismic analyses, which will potentially permit removal of a considerable number of piping supports, particularly snubbers. This in turn will lead to more flexible piping systems which will be less susceptible to thermal cracking, will be easier to maintain and inspect, as well as less costly

  7. Investigation of the binding free energies of FDA approved drugs against subtype B and C-SA HIV PR: ONIOM approach.

    Science.gov (United States)

    Sanusi, Z K; Govender, T; Maguire, G E M; Maseko, S B; Lin, J; Kruger, H G; Honarparvar, B

    2017-09-01

    Human immune virus subtype C is the most widely spread HIV subtype in Sub-Sahara Africa and South Africa. A profound structural insight on finding potential lead compounds is therefore necessary for drug discovery. The focus of this study is to rationalize the nine Food and Drugs Administration (FDA) HIV antiviral drugs complexed to subtype B and C-SA PR using ONIOM approach. To achieve this, an integrated two-layered ONIOM model was used to optimize the geometrics of the FDA approved HIV-1 PR inhibitors for subtype B. In our hybrid ONIOM model, the HIV-1 PR inhibitors as well as the ASP 25/25' catalytic active residues were treated at high level quantum mechanics (QM) theory using B3LYP/6-31G(d), and the remaining HIV PR residues were considered using the AMBER force field. The experimental binding energies of the PR inhibitors were compared to the ONIOM calculated results. The theoretical binding free energies (?G bind ) for subtype B follow a similar trend to the experimental results, with one exemption. The computational model was less suitable for C-SA PR. Analysis of the results provided valuable information about the shortcomings of this approach. Future studies will focus on the improvement of the computational model by considering explicit water molecules in the active pocket. We believe that this approach has the potential to provide much improved binding energies for complex enzyme drug interactions. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  9. LWR primary coolant pipe rupture test rig

    International Nuclear Information System (INIS)

    Yoshitoshi, Shyoji

    1978-01-01

    The rupture test rig for primary coolant pipes is constructed in the Japan Atomic Energy Research Institute to verify the reliability of the primary coolant pipes for both PWRs and BWRs. The planned test items consisted of reaction force test, restraint test, whip test, jet test and continuous release test. A pressure vessel of about 4 m 3 volume, a circulating pump, a pressurizer, a heater, an air cooler and the related instrumentation and control system are included in this test rig. The coolant test condition is 160 kg/cm 2 g, 325 deg C for PWR test, and 70 kg/cm 2 g, saturated water and steam for BWR test, 100 ton of test load for the ruptured pipe bore of 8B Schedule 160, and 20 lit/min. discharge during 20 h for continuous release of coolant. The maximum pit internal pressure was estimated for various pipe diameters and time under the PWR and BWR conditions. The spark rupturing device was adopted for the rupture mechanics in this test rig. The computer PANAFACOM U-300 is used for the data processing. This test rig is expected to operate in 1978 effectively for the improvement of reliability of LWR primary coolant pipes. (Nakai, Y.)

  10. Evaluation of seismic margins for an in-plant piping system

    International Nuclear Information System (INIS)

    Kot, C.A.; Srinivasan, M.G.; Hsieh, B.J.

    1991-01-01

    Earthquake experience as well as experiments indicate that, in general, piping systems are quite rugged in resisting seismic loadings. Therefore there is a basis to hold that the seismic margin against pipe failure is very high for systems designed according to current practice. However, there is very little data, either from tests or from earthquake experience, on the actual margin or excess capacity (against failure from seismic loading) of in-plant piping systems. Design of nuclear power plant piping systems in the US is governed by the criteria given in the ASME Boiler and Pressure Vessel (B ampersand PV) Code, which assure that pipe stresses are within specified allowable limits. Generally linear elastic analytical methods are used to determine the stresses in the pipe and forces in pipe supports. The objective of this study is to verify that piping designed according to current practice does indeed have a large margin against failure and to quantify the excess capacity for piping and dynamic pipe supports on the basis of data obtained in a series of high-level seismic experiments (designated SHAM) on an in-plant piping system at the HDR (Heissdampfreaktor) Test Facility in Germany. Note that in the present context, seismic margin refers to the deterministic excess capacities of piping or supports compared to their design capacities. The excess seismic capacities or margins of a prototypical in-plant piping system and its components are evaluated by comparing measured inputs and responses from high-level simulated seismic experiments with design loads and allowables. Large excess capacities are clearly demonstrated against pipe and overall system failure with the lower bound being about four. For snubbers the lower bound margin is estimated at two and for rigid strut supports at five. 4 refs., 2 figs., 2 tabs

  11. Fundamentals of piping design

    CERN Document Server

    Smith, Peter

    2013-01-01

    Written for the piping engineer and designer in the field, this two-part series helps to fill a void in piping literature,since the Rip Weaver books of the '90s were taken out of print at the advent of the Computer Aid Design(CAD) era. Technology may have changed, however the fundamentals of piping rules still apply in the digitalrepresentation of process piping systems. The Fundamentals of Piping Design is an introduction to the designof piping systems, various processes and the layout of pipe work connecting the major items of equipment forthe new hire, the engineering student and the vetera

  12. Heat pipe

    International Nuclear Information System (INIS)

    Triggs, G.W.; Lightowlers, R.J.; Robinson, D.; Rice, G.

    1986-01-01

    A heat pipe for use in stabilising a specimen container for irradiation of specimens at substantially constant temperature within a liquid metal cooled fast reactor, comprises an evaporator section, a condenser section, an adiabatic section therebetween, and a gas reservoir, and contains a vapourisable substance such as sodium. The heat pipe further includes a three layer wick structure comprising an outer relatively fine mesh layer, a coarse intermediate layer and a fine mesh inner layer for promoting unimpeded return of condensate to the evaporation section of the heat pipe while enhancing heat transfer with the heat pipe wall and reducing entrainment of the condensate by the upwardly rising vapour. (author)

  13. 34 CFR 106.71 - Procedures.

    Science.gov (United States)

    2010-07-01

    ...) Public institutions of undergraduate higher education, 106.15(e) Recruitment, [34, 35]; 106.23 Specific...(d) Pre-Employment Inquiry Recruitment, [83, 90, 91, 95] Sex as a BFOQ, [96]; 106.61 Student... organizations”, 106.31(c) Fraternities/Sororities Social, [53, 27, 28]; 106.14(a) Business/professional, [40, 53...

  14. 21 CFR 106.30 - Finished product evaluation.

    Science.gov (United States)

    2010-04-01

    ... degradation; and (ii) All nutrients not previously analyzed for by the manufacturers, unless each in-process... specified in § 106.20(b). No analyses are needed for linoleic acid, vitamin D, vitamin K, choline, inositol... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate...

  15. Transfer and accumulation of 106Ru from phytoplankton (Dunaliella bioculata) to zooplankton (Artemia salina)

    International Nuclear Information System (INIS)

    Izumo, Yoshiro; Takase, Akira

    1982-01-01

    106 Ru is one of the most abundant radionuclides to be released from the unclear-spent fuel reprocessing plant to oceans. This paper deals with transfer and accumulation of the radionuclide from phytoplankton (Dunaliella) to zooplankton (Artemia) in the graizing food chain of marine organisms. Each plankton was reared in the radioactive sea water A (filtrated and circulated through sandy mud, and the radioactive concentration decreased and atteined to constant after addition of 106 Ru), B (not filtrated and circulated, and the radioactive concentration decreased and atteined to constant) and C (not filtrated and circulated, the radioactive concentration decreased, but did not attein to constant), respectively, and investigated accumulations of 106 Ru. Then, accumulations of 106 Ru in Artemia by the ingestion of each diet (Dunaliella) contaminated with 106 Ru in each water, were investigated and compared with those from each water. Concentration factors of 106 Ru for the planktons reared in the radioactive sea waters were different among these waters. The difference can be attributable to that of physicochemical states of 106 Ru in the waters. It was found that 106 Ru would be accumulated by Artemia from the water A about 10 times higher than from the contaminated diet (Dunaliella) in this water, however from the contaminated diet (Dunaliella) in the water B about 2.2 times higher than from the last water. (author)

  16. Heat pipe and method of production of a heat pipe

    International Nuclear Information System (INIS)

    Kemp, R.S.

    1975-01-01

    The heat pipe consists of a copper pipe in which a capillary network or wick of heat-conducting material is arranged in direct contact with the pipe along its whole length. Furthermore, the interior space of the tube contains an evaporable liquid for pipe transfer. If water is used, the capillary network consists of, e.g., a phosphorus band network. To avoid contamination of the interior of the heat pipe during sealing, its ends are closed by mechanical deformation so that an arched or plane surface is obtained which is in direct contact with the network. After evacuation of the interior space, the remaining opening is closed with a tapered pin. The ratio wall thickness/tube diameter is between 0.01 and 0.6. (TK/AK) [de

  17. Abordagem profissional da violência familiar contra o idoso em uma unidade básica de saúde

    OpenAIRE

    Wanderbroocke,Ana Claudia Nunes de Souza; Moré,Carmen Leontina Ojeda Ocampo

    2013-01-01

    O presente artigo tem como objetivo descrever a abordagem profissional da violência familiar contra idosos em uma unidade básica de saúde (UBS). Trata-se de pesquisa qualitativa, com dados coletados por meio de observação participante com registro em diário de campo e entrevistas semiestruturadas. Participaram das entrevistas dez profissionais da UBS. Os dados foram analisados segundo o referencial da Grounded Theory e duas categorias foram discutidas: manejo profissional de situações de viol...

  18. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A; Parisher

    2000-01-01

    Pipe designers and drafters provide thousands of piping drawings used in the layout of industrial and other facilities. The layouts must comply with safety codes, government standards, client specifications, budget, and start-up date. Pipe Drafting and Design, Second Edition provides step-by-step instructions to walk pipe designers and drafters and students in Engineering Design Graphics and Engineering Technology through the creation of piping arrangement and isometric drawings using symbols for fittings, flanges, valves, and mechanical equipment. The book is appropriate primarily for pipe

  19. Direito à saúde e saneamento básico na estratégia saúde da família no Complexo do Alemão - doi: 10.4025/actascihealthsci.v32i2.7449 Right to health and basic sanitation in health strategy to the family in “Complexo do Alemão” - doi: 10.4025/actascihealthsci.v32i2.7449

    OpenAIRE

    Liliana Angel Vargas; Simony Costa Oliveira

    2010-01-01

    Este artigo surge o interesse de estimular a reflexão sobre as possibilidades da garantia do direito ao saneamento básico no Complexo do Alemão - Rio de Janeiro, Estado do Rio de Janeiro a partir da Estratégia da Saúde da Família (ESF), na medida em que se entende o direito ao saneamento básico intimamente integrado ao direito à saúde. O estudo se propôs identificar a percepção dos profissionais que atuam na Unidade de Saúde da Família (USF) Nova Brasília sobre o direito a saneamento básico, ...

  20. Evidências empíricas das políticas de sanemaneto básico sobre indicadores de saúde para municípios brasileiros

    OpenAIRE

    Teixeira, Lucas Iten

    2011-01-01

    Este artigo propõe analisar o efeito de variáveis relacionadas ao saneamento básico sobre indicadores de saúde através de dados em painel de municípios brasileiros. Através de base de dados de DataSUS, IBGE e do SNIS, avaliamos se os indicadores de saneamento afetam indicadores de saúde como mortalidade e morbidade separados por faixa etária e tipos de doença nos municípios entre 2001 a 2008. Trabalhamos com diferentes amostras por conta do desbalanceamento do painel, dado que há dados fal...

  1. In-plane and out-of-plane bending tests on carbon steel pipe bends

    International Nuclear Information System (INIS)

    Brouard, D.; Tremblais, A.; Vrillon, B.

    1979-01-01

    The objectives of these tests were to obtain experimental results on bends behaviour in elastic and plastic regime by in plane and out of plane bending. Results were used to improve the computer model, for large distorsion of bends, to be used in a simplified beam type computer code for piping calculations. Tests were made on type ANSI B 169 DN 5 bends in ASTM A 106 Grade B carbon steel. These tests made it possible to measure, for identical bends, in elastic regime, the flexibility factors and, in plastic regime, the total evolution in opening, in closing and out of plane. Flexibility factors of 180 0 bend without flanges are approximately the same in opening and in closing. The end effect due to flanges is not very significant, but it is important for 90 0 bends. In plastic regime, collapse loads or collapse moments of bends depends also of both the end effects and the angle bend. The end effects and the angle bend are more sensitive in opening than in closing. The interest of these tests is to procure some precise evolution curves of identical bends well characterized in geometry and metal strength, deflected in large distorsions. (orig./HP)

  2. 40 CFR 761.247 - Sample site selection for pipe segment removal.

    Science.gov (United States)

    2010-07-01

    ... end of the pipe segment. (3) If the pipe segment is cut with a saw or other mechanical device, take..., take samples from a total of seven segments. (A) Sample the first and last segments removed. (B) Select... total length for purposes of disposal, take samples of each segment that is 1/2 mile distant from the...

  3. Psicologia clínica existencialista na atenção básica à saúde: um relato de atuação

    Directory of Open Access Journals (Sweden)

    Zuleica Pretto

    Full Text Available A proposta deste artigo é compartilhar uma experiência de intervenção em Psicologia clínica a partir da abordagem existencialista de Jean-Paul Sartre, realizada em uma clínica integrada de atenção básica à saúde vinculada ao Sistema Único de Saúde (SUS, na Grande Florianópolis. O objetivo do atendimento psicológico é criar condições, junto aos sujeitos, para que sejam capazes de superar dificuldades, e auxiliálos a reconstruir seus projetos de ser. A demanda da clínica é diversificada - crianças, adolescentes, adultos, idosos e famílias -, e existem queixas de diferentes ordens, como dificuldades na aprendizagem, nas relações familiares, nas relações amorosas, na sexualidade e dificuldades provenientes de doenças orgânicas, de violência física e sexual e de psicopatologias variadas. Em sua atuação, considera-se que, do profissional que trabalha em uma unidade básica de saúde, é exigida uma diversidade de instrumentos teóricos e metodológicos e que a abordagem existencialista de Jean -Paul Sartre tem a possibilidade de abarcar, pela amplitude de sua teoria e de sua metodologia, as diferentes exigências apresentadas.

  4. Round dance in pipes; Runddans i roer

    Energy Technology Data Exchange (ETDEWEB)

    Steensen, Anders J.

    2004-07-01

    On the offshore production plants, oil, water, and gas are separated from the well streams. The oil is sold on the market while the gas is in part exported, in part reinjected into the wells in large quantities to sustain the pressure in the reservoirs. The water is cleaned, some is pumped to the sea and some returned to the reservoir. Although these processes may seem straightforward, they cause a great deal of worry since there are so many complex processing and pipe systems taking up space. Pipes vibrate and make noise, most often because of pressure fluctuations created by the flowing liquid and gas. Or vortices form inside the pipe that make the whole pipe drone. In the offshore activities, these phenomena can be very annoying; on the Statfjord B platform people baulked at entering the area where the produced water treatment system was standing. A new system had to be developed since existing equipment would take up too much space. In the new system, a pipe section is installed in the pipeline that makes the gas/liquid mixture spin rapidly as in a centrifuge. The gas collects along the centre of the pipe and is tapped off. The principle can also be used to separate liquid from gas. In many gas treatment systems, liquid accumulation, or carry over, is detrimental. But gas dehydrators are usually dimensioned for a minimal content of liquid in the gas. Important features of these new pipe-based separators are that they are small, remove bottlenecks in the production, and are straightforward to install. But operators who live with the problems every day are very sceptical about the new separators and should be given the opportunity to test them on land before they are installed in the field.

  5. Thermal stability of the C106 dye in robust electrolytes

    DEFF Research Database (Denmark)

    Lund, Torben; Phuong, Nguyen Tuyet; Pechy, Peter

    -MPN) introduced by Gao et al. in 2008. [1]. Figure 1 Thermal degradation of C106 bound to TiO2 at 80 ºC in dark as a function of heating time. ● C106 = RuLL´(NCS)2 ■ RuLL´(NCS)(NBB)+ ▲ RuLL´(NCS)(3-MPN)+ The C106 dye was attached to the surface of TiO2 nano-particles and stable colloidal solutions...... of the particles were prepared in electrolyte mixture B. The solutions were thermally treated at 80 ◦C for 0-2000 hours followed by dye extraction and analysis by HPLC coupled to UV/Vis and electro spray mass spectrometry [2]. Figure 1 shows the concentration profiles of C106 samples prepared under ambient...... and glove box conditions as a function of the heating time. Preparation of the samples under strict atmospheric moisture control in a glove box gives the best results with a steady state surface concentration of 80% intact C106 and 20% NBB substitution product after ~1500 hours of heating at 80 ºC. If dye...

  6. Atenção básica à saúde masculina: possibilidades e limites no atendimento noturno

    Directory of Open Access Journals (Sweden)

    Sharllene Vanessa Lima Cordeiro

    2014-12-01

    Full Text Available Objetivo: Analisar as contribuições advindas com a ampliação do horário de funcionamento das Unidades Básicas de Saúde, para o horário noturno, no que concerne ao atendimento às necessidades de saúde da clientela masculina. Métodos: Estudo exploratório, com abordagem qualitativa, realizado com oito enfermeiros atuantes em Unidades Básicas de Saúde que possuem atendimento noturno no Município de João Pessoa/PB. A coleta de dados foi realizada por meio de entrevista semiestruturada e as falas submetidas à análise de conteúdo. Resultados: Emergiram quatro categorias: Estratégias adotadas para ampliar o atendimento nas Unidades Básicas de Saúde; Quantitativo de atendimento noturno da população masculina; Campos de atendimento as demandas de saúde masculina; Dificuldades vivenciadas no atendimento noturno. Conclusão: Os achados revelam eficácia desta estratégia de atendimento à saúde da clientela masculina, sobretudo aos usuários trabalhadores.

  7. Heat pipes and use of heat pipes in furnace exhaust

    Science.gov (United States)

    Polcyn, Adam D.

    2010-12-28

    An array of a plurality of heat pipe are mounted in spaced relationship to one another with the hot end of the heat pipes in a heated environment, e.g. the exhaust flue of a furnace, and the cold end outside the furnace. Heat conversion equipment is connected to the cold end of the heat pipes.

  8. Drill pipe bridge plug

    International Nuclear Information System (INIS)

    Winslow, D.W.; Brisco, D.P.

    1991-01-01

    This patent describes a method of stopping flow of fluid up through a pipe bore of a pipe string in a well. It comprises: lowering a bridge plug apparatus on a work string into the pipe string to a position where the pipe bore is to be closed; communicating the pipe bore below a packer of the bridge plug apparatus through the bridge plug apparatus with a low pressure zone above the packer to permit the fluid to flow up through the bridge plug apparatus; engaging the bridge plug apparatus with an internal upset of the pipe string; while the fluid is flowing up through the bridge plug apparatus, pulling upward on the work string and the bridge plug apparatus and thereby sealing the packer against the pipe bore; isolating the pipe bore below the packer from the low pressure zone above the packer and thereby stopping flow of the fluid up through the pipe bore; disconnecting the work string from the bridge plug apparatus; and maintaining the bridge plug apparatus in engagement with the internal upset and sealed against the pipe bore due to an upward pressure differential applied to the bridge plug apparatus by the fluid contained therebelow

  9. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  10. Miniature Heat Pipes

    Science.gov (United States)

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  11. Riser pipe elevator

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, W.; Jimenez, A.F.

    1987-09-08

    This patent describes a method for storing and retrieving a riser pipe, comprising the steps of: providing an upright annular magazine comprised of an inside annular wall and an outside annular wall, the magazine having an open top; storing the riser pipe in a substantially vertically oriented position within the annular magazine; and moving the riser pipe upwardly through the open top of the annular magazine at an angle to the vertical along at least a portion of the length of the riser pipe.

  12. Atenção à saúde da criança na rede básica: análise de dissertações e teses de enfermagem

    Directory of Open Access Journals (Sweden)

    Andresa Braun Novaczyk

    2008-12-01

    Full Text Available Este trabalho teve como objetivo analisar a produção científica dos programas de pós-graduação em enfermagem sobre a assistência à criança na atenção básica. A pesquisa documental foi realizada nos catálogos do Centro de Estudos e Pesquisas em Enfermagem (CEPEN, da Associação Brasileira de Enfermagem (ABEn, no período compreendido entre 2000 e 2006. Foram identificados 15 estudos que, após análise do conteúdo, permitiu a identificação de três categorias temáticas: a prática da enfermagem na atenção à saúde da criança na rede básica; a atenção à saúde da criança no PSF; a enfermagem e a busca pela assistência integral à saúde da criança. Conclui-se que a prática de enfermagem ainda está centrada no modelo médico hegemônico, o qual privilegia práticas prioritariamente curativas, fragmentadas e de baixa resolutividade. Porém, existem inúmeros esforços por parte dos enfermeiros na busca da promoção da saúde e da integralidade.

  13. Irrecoverable pressure loss coefficients for two out-of-plane piping elbows at high Reynolds number

    Energy Technology Data Exchange (ETDEWEB)

    Coffield, R.D.; Hammond, R.B.; McKeown, P.T.

    1999-02-08

    Pressure drops of multiple piping elbows were experimentally determined for high Reynolds number flows. The testing described has been performed in order to reduce uncertainties in the currently used methods for predicting irrecoverable pressure losses and also to provide a qualification database for computational fluid dynamics (CFD) computer codes. The earlier high Reynolds number correlations had been based on extrapolations over several orders of magnitude in Reynolds number from where the original database existed. Recent single elbow test data shows about a factor of two lower elbow pressure loss coefficient (at 40x 106 Reynolds number) than those from current correlations. This single piping elbow data has been extended in this study to a multiple elbow configuration of two elbows that are 90o out-of-plane relative to each other. The effects of separation distance and Reynolds number have been correlated and presented in a form that can be used for design application. Contrary to earlier extrapolations from low Reynolds numbers (Re c 1.0x 106), a strong Reynolds number dependence was found to exist. The combination of the high Reynolds number single elbow data with the multiple elbow interaction effects measured in this study shows that earlier design correlations are conservative by significant margins at high Reynolds numbers. Qualification of CFD predictions with this new high Reynolds number database will help guide the need for additional high Reynolds number testing of other piping configurations. The study also included velocity measurements at several positions downstream of the first and second test elbows using an ultrasonic flowmeter. Reasonable agreement after the first test elbow was found relative to flow fields that are known to exist from low Reynolds number visual tests and also from CFD predictions. This data should help to qualify CFD predictions of the three-dimensional flow stream downstream of the second test elbow.

  14. Microseismic response characteristics modeling and locating of underground water supply pipe leak

    Science.gov (United States)

    Wang, J.; Liu, J.

    2015-12-01

    In traditional methods of pipeline leak location, geophones must be located on the pipe wall. If the exact location of the pipeline is unknown, the leaks cannot be identified accurately. To solve this problem, taking into account the characteristics of the pipeline leak, we propose a continuous random seismic source model and construct geological models to investigate the proposed method for locating underground pipeline leaks. Based on two dimensional (2D) viscoacoustic equations and the staggered grid finite-difference (FD) algorithm, the microseismic wave field generated by a leaking pipe is modeled. Cross-correlation analysis and the simulated annealing (SA) algorithm were utilized to obtain the time difference and the leak location. We also analyze and discuss the effect of the number of recorded traces, the survey layout, and the offset and interval of the traces on the accuracy of the estimated location. The preliminary results of the simulation and data field experiment indicate that (1) a continuous random source can realistically represent the leak microseismic wave field in a simulation using 2D visco-acoustic equations and a staggered grid FD algorithm. (2) The cross-correlation method is effective for calculating the time difference of the direct wave relative to the reference trace. However, outside the refraction blind zone, the accuracy of the time difference is reduced by the effects of the refracted wave. (3) The acquisition method of time difference based on the microseismic theory and SA algorithm has a great potential for locating leaks from underground pipelines from an array located on the ground surface. Keywords: Viscoacoustic finite-difference simulation; continuous random source; simulated annealing algorithm; pipeline leak location

  15. Evaluation of creep damage due to stress relaxation in SA533 grade B class 1 and SA508 class 3 pressure vessel steels

    International Nuclear Information System (INIS)

    Hoffmann, C.L.; Urko, W.

    1993-01-01

    Creep damage can result from stress relaxation of residual stresses in components when exposed to high temperature thermal cycles. Pressure vessels, such as the reactor vessel of the modular high-temperature gas reactor (MHTGR), which normally operate at temperatures well below the creep range can develop relatively high residual stresses in high stress locations. During short term excursions to elevated-temperatures, creep damage can be produced by the loadings on the vessel. In addition, residual stresses will relax out, causing greater creep damage in the pressure vessel material than might otherwise be calculated. The evaluation described in this paper assesses the magnitude of the creep damage due to relaxation of residual stresses resulting from short term exposure of the pressure vessel material to temperatures in the creep range. Creep relaxation curves were generated for SA533 Grade B, Class 1 and SA508 Class 3 pressure vessel steels using finite element analysis of a simple uniaxial truss loaded under constant strain conditions to produce an initial axial stress equal to 1.25 times the material yield strength at temperature. The strain is held constant for 1000 hours at prescribed temperatures from 700 F to 1000 F. The material creep law is used to calculate the relaxed stress for each time increment. The calculated stress relaxation versus time curves are compared with stress relaxation test data. Creep damage fractions are calculated by integrating the stress relaxation versus time curves and performing a linear creep damage summation using the minimum stress to rupture curves at the respective relaxation temperatures. Cumulative creep damage due to stress relaxation as a function of time and temperature is derived from the linear damage summation

  16. Altitude-wind-tunnel investigation of tail-pipe burning with a Westinghouse X24C-4B axial-flow turbojet engine

    Science.gov (United States)

    Fleming, William A; Wallner, Lewis E

    1948-01-01

    Thrust augmentation of an axial-flow type turbojet engine by burning fuel in the tail pipe has been investigated in the NACA Cleveland altitude wind tunnel. The performance was determined over a range of simulated flight conditions and tail-pipe fuel flows. The engine tail pipe was modified for the investigation to reduce the gas velocity at the inlet of the tail-pipe combustion chamber and to provide an adequate seat for the flame; four such modifications were investigated. The highest net-thrust increase obtained in the investigation was 86 percent with a net thrust specific fuel consumption of 2.91 and a total fuel-air ratio of 0.0523. The highest combustion efficiencies obtained with the four configurations ranged from 0.71 to 0.96. With three of the tail-pipe burners, for which no external cooling was provided, the exhaust nozzle and the rear part of the burner section were bright red during operation at high tail-pipe fuel-air ratios. With the tail-pipe burner for which fuel and water cooling were provided, the outer shell of the tail-pipe burner showed no evidence of elevated temperatures at any operating condition.

  17. Flow induced vibrations of secondary piping of L.M.F.B.R

    International Nuclear Information System (INIS)

    Gibert, R.J.; Axisa, F.

    1977-01-01

    A method for evaluating the characteristics of vibrations caused by internal flow in three-dimensional piping systems conveying high density fluids, is presented. The excitation of the circuit is mainly caused by the flow singularities, and it is shown that the problem may be reduced to calculate the response of the circuit to an acoustical pressure discontinuity, localized at each flow singularity. The theoretical formulation of the coupled acoustical-mechanical problem and its numerical solution by the french computer code TEDEL, are given. An experimental test of the method is described. The tested piping system consists of a stainless steel tube circuit comprising four 90 0 bends, conveying water. Vibrations are excited by a half closed gate valve. Satisfactory results are obtained concerning both the frequencies of resonance of the circuit and the level of the vibrations observed

  18. Corrosion evaluation in insulated pipes by non destructive testing method

    International Nuclear Information System (INIS)

    Abd Razak Hamzah; Azali Muhammad; Mohammad Pauzi Ismail; Abd Nassir Ibrahim; Abd Aziz Mohamed; Sufian Saad; Saharuddin Sayuti; Shukri Ahmad

    2002-01-01

    In engineering plants, detection of corrosion and evaluation of deposit in insulated pipes using radiography method are considered as a very challenging tasks. In General this degradation problem is attributed to water condensation. It causes the formation of deposit and scale inside the pipe, as well as between the insulation and pipe in cold temperature pipes. On the other hand, for hot temperature pipes the main problem is mainly due to corrosion/erosion attack inside the pipe. In the study of corrosion in pipelines, one of the most important parameters to be monitored and measured is the wall thickness. Currently, most pipeline corrosion monitoring and evaluation for both insulated and non-insulated pipes is performed using an ultrasonic method. The most common technique is that based on the A-Scan, using either a normal flaw detector or some form of dedicated equipment. However, with recent development of ultrasonic technology, more advance method, namely B-Scan and C-scan techniques are also available. The most notable disadvantage of using this method is that the insulation covering the pipe has to be removed before the inspection can be carried out and this is considered as not so cost effective. Due to this reason, the possibility of employing other alternative NDT method, namely radiographic testing method were studied. The technique used in this studied are known as tangential technique. In this study it was found that the result found using tangential technique is consistent with the actual thickness of the pipe. Result of this study is presented and discussed in this paper. (Author)

  19. Studies on transfer and accumulation of 106Ru from seaweed to fish through crustacea, 2

    International Nuclear Information System (INIS)

    Izumo, Yoshiro

    1982-01-01

    This paper deals with transfer and accumulation of 106 Ru in a model of the graizing food chain of marine organisms: the radioactive sea water → seaweed (Chondrus crispus) → crustacea (prawn, Palaemon serratus) → fish (plaice, Pleuronectes platessa). The seaweeds were cultured in the radioactive sea waters A (filtrated and circulated through sandy mud, the radioactive concentration decreased and atteined to constant after addition of 106 Ru), B (not filtrated and circulated, the radioactive concentration decreased and atteined to constant) and C (not filtrated and circulated, the radioactive concentration decreased, but did not attein to constant), respectively, and investigated accumulations of 106 Ru. Thereafter, accumulations of 106 Ru in prawns and plaice by the ingestions of their diets (the seaweeds contaminated with 106 Ru in each water and the meats of prawns accumulated 106 Ru from each diet, respectively), were investigated and compared with those from the radioactive sea waters reported previously. It was shown that 106 Ru would be accumulated by the prawns from the sea water A about 3 times higher than from the contaminated diet in this water, however from the contaminated diets in the waters B and C about 2 times, respectively, higher than from each water. While, accumulations of 106 Ru by the plaice from each diet were negligible in comparison with those from each water. No higher concentrations of 106 Ru were observed in these organisms from lower to higher in the trophic level. (author)

  20. 78 FR 79295 - Airworthiness Directives; CFM International S.A. Turbofan Engines

    Science.gov (United States)

    2013-12-30

    ... Airworthiness Directives; CFM International S.A. Turbofan Engines AGENCY: Federal Aviation Administration (FAA... International (CFM) S.A. CFM56-3 and CFM56-7B series turbofan engines with certain accessory gearboxes (AGBs... of total loss of engine oil from CFM56 series turbofan engines while in flight. This AD requires an...

  1. Development of LBB Piping Evaluation Diagram for APR 1000 Main Steam Line Piping

    International Nuclear Information System (INIS)

    Yang, J. S.; Jeong, I. L.; Park, C. Y.; Bai, S. Y.

    2010-01-01

    This paper presents the piping evaluation diagram (PED) to assess the applicability of Leak-Before- Break(LBB) for APR 1000 main steam line piping. LBB-PED of APR 1000 main steam line piping is independent of its piping geometry and has a function of the loads applied in piping system. Also, in order to evaluate LBB applicability during construction process with only the comparative evaluation of material properties between actually used and expected, the expected changes of material properties are considered in the LBB-PED. The LBB-PED, therefore, can be used for quick LBB evaluation of APR 1000 main steam line piping of both design and construction

  2. PIPE STRESS and VERPIP codes for stress analysis and verifications of PEC reactor piping

    International Nuclear Information System (INIS)

    Cesari, F.; Ferranti, P.; Gasparrini, M.; Labanti, L.

    1975-01-01

    To design LMFBR piping systems following ASME Sct. III requirements unusual flexibility computer codes are to be adopted to consider piping and its guard-tube. For this purpose PIPE STRESS code previously prepared by Southern-Service, has been modified. Some subroutine for detailed stress analysis and principal stress calculations on all the sections of piping have been written and fitted in the code. Plotter can also be used. VERPIP code for automatic verifications of piping as class 1 Sct. III prescriptions has been also prepared. The results of PIPE STRESS and VERPIP codes application to PEC piping are in section III of this report

  3. Piping research program plan

    International Nuclear Information System (INIS)

    1988-09-01

    This document presents the piping research program plan for the Structural and Seismic Engineering Branch and the Materials Engineering Branch of the Division of Engineering, Office of Nuclear Regulatory Research. The plan describes the research to be performed in the areas of piping design criteria, environmentally assisted cracking, pipe fracture, and leak detection and leak rate estimation. The piping research program addresses the regulatory issues regarding piping design and piping integrity facing the NRC today and in the foreseeable future. The plan discusses the regulatory issues and needs for the research, the objectives, key aspects, and schedule for each research project, or group of projects focussing of a specific topic, and, finally, the integration of the research areas into the regulatory process is described. The plan presents a snap-shot of the piping research program as it exists today. However, the program plan will change as the regulatory issues and needs change. Consequently, this document will be revised on a bi-annual basis to reflect the changes in the piping research program. (author)

  4. Pipe rupture test results: 4-inch pipe whip tests under PWR LOCA conditions

    International Nuclear Information System (INIS)

    Miyazaki, Noriyuki; Ueda, Shuzo; Isozaki, Toshikuni; Kato, Rokuro; Kurihara, Ryoichi; Yano, Toshikazu; Miyazono, Shohachiro

    1982-09-01

    This report summarizes the results of 4-inch pipe whip tests (RUN No. 5506, 5507, 5508 and 5604) under the PWR LOCA conditions. The dynamic behaviors of the test pipe and restraints were studied in the tests. In the tests, the gap between the test pipe and the restraints was kept at the constant value of 8.85 mm and the overhang length was varied from 250 mm to 650 mm. The dynamic behaviors of the test pipe and the restraint were made clear by the outputs of strain gages and the measurements of residual deformations. The data of water hammer in subcooled water were also obtained by the pressure transducers mounted on the test pipe. The main conclusions obtained from the tests are as follows. (1) The whipping of pipe can be prevented more effectively as the overhang length becomes shorter. (2) The load acting on the restraint-support structure becomes larger as the overhang length becomes shorter. (3) The restraint farther from the break location does not limit the pipe movement except for the first impact when the overhang length is long. (4) The ultimate moment M sub(u) of the pipe at the restraint location can be used to predict the plastic collapse of the whipping pipe. (5) The restraints slide along the pipe axis and are subjected to bending moment, when the overhang length is long. (author)

  5. Development of total systems of piping stress analysis and evaluation: ISAPPS

    International Nuclear Information System (INIS)

    Oki, Teizaburo; Koyanagi, Ryoichi; Fukuda, Masanao

    1978-01-01

    IHI has developed the systems of piping stress analysis and evaluation: ISAPPS (IHI Stress Analysis Program for Piping Systems), which are further described in this paper. In addition, the results of structural analysis and heat transfer analysis were confirmed. An example of stress evaluation in accordance with the modified ASME Code Sec. III is shown. ISAPPS consists of the following seven parts, and is designed for easy adoption of other programs by making modifications. 1. Piping design oriented language programs 2. Structural analysis programs 3. Isometric plotting programs 4. Multi-file dumping program 5. Load combination program 6. Heat transfer program 7. Stress evaluation programs As one of the examples of structural analysis programs, IHI make use of the modified SAP IV developed by the University of California. Evaluations of stresses are performed in accordance with: 1. ASME Boiler and Pressure Vessel Code, Sec. III Class 1, 2 and 3 2. ANSI Code, B31.1 and B31.3 3. MITI (Ministry of International Trade and Industry ) Code ISAPPS is very useful for design of nuclear and chemical pipings and so on. (author)

  6. Analytical studies of blowdown thrust force and dynamic response of pipe at pipe rupture accident

    International Nuclear Information System (INIS)

    Miyazaki, Noriyuki

    1985-01-01

    The motion of a pipe due to blowdown thrust when the pipe broke is called pipe whip. In LWR power plants, by installing restraints, the motion of a pipe when it broke is suppressed, so that the damage does not spread to neighboring equipment by pipe whip. When the pipe whip of a piping system in a LWR power plant is analyzed, blowdown thrust and the dynamic response of a pipe-restraint system are calculated with a computer. The blowdown thrust can be calculated by using such physical quantities as the pressure, flow velocity, density and so on in the system at the time of blowdown, obtained by the thermal-fluid analysis code at LOCA. The dynamic response of a piping-restraint system can be determined by the stress analysis code using finite element method taking the blowdown thrust as an external force acting on the piping. In this study, the validity of the analysis techniques was verified by comparing with the experimental results of the measurement of blowdown thrust and the pipe whip of a piping-restraint system, carried out in the Japan Atomic Energy Research Institute. Also the simplified analysis method to give the maximum strain on a pipe surface is presented. (Kako, I.)

  7. Atenção básica à saúde na fronteira Brasil-Uruguai: um olhar a partir dos gestores

    Directory of Open Access Journals (Sweden)

    Carla Gabriela Cavini Bontempo

    2013-12-01

    Full Text Available O presente trabalho aborda o acesso à atenção básica na fronteira Brasil-Uruguai, tida como uma das mais porosas e na qual ocorre muita interação entre a população que habita ambos os países, a partir de pesquisa de campo realizada em três pares de cidades-gêmeas durante o ano de 2012. Através de entrevistas semiestruturadas com gestores municipais e de saúde brasileiros e uruguaios, foi possível apreender que embora haja o reconhecimento por parte dos gestores de que a saúde deveria ter acesso universal, na fala de grande parte deles o acesso somente é permitido aos cidadãos (cidadania entendida como nacionalidade, e ao estrangeiro são disponibilizados serviços que não tenham um custo elevado, ou que não tenha remuneração por procedimento, como é o caso de participação em grupos de idosos, hipertensos e diabéticos. Por parte dos gestores brasileiros houve menção ao desejo de oferecer à população do país vizinho acesso ao serviço brasileiro, mas foi apontada a burocracia e a rigidez da necessidade de apresentação do cartão nacional do sistema único de saúde (Cartão SUS como empecilho na efetivação do atendimento ao não-nacional. Por parte do Uruguai, que dentre as cidades pesquisadas detinha uma melhor infraestrutura em saúde, o atendimento aos brasileiros em casos de emergência se dá de forma menos burocrática nos hospitais, sendo possível também o acesso ao setor privado mediante pagamento. Toda essa burocracia também desvela as dificuldades em se programar ações de cooperação em saúde entre os países, em possíveis trocas de serviços especializados.

  8. Electron Cloud in Steel Beam Pipe vs Titanium Nitride Coated and Amorphous Carbon Coated Beam Pipes in Fermilab's Main Injector

    Energy Technology Data Exchange (ETDEWEB)

    Backfish, Michael

    2013-04-01

    This paper documents the use of four retarding field analyzers (RFAs) to measure electron cloud signals created in Fermilab’s Main Injector during 120 GeV operations. The first data set was taken from September 11, 2009 to July 4, 2010. This data set is used to compare two different types of beam pipe that were installed in the accelerator. Two RFAs were installed in a normal steel beam pipe like the rest of the Main Injector while another two were installed in a one meter section of beam pipe that was coated on the inside with titanium nitride (TiN). A second data run started on August 23, 2010 and ended on January 10, 2011 when Main Injector beam intensities were reduced thus eliminating the electron cloud. This second run uses the same RFA setup but the TiN coated beam pipe was replaced by a one meter section coated with amorphous carbon (aC). This section of beam pipe was provided by CERN in an effort to better understand how an aC coating will perform over time in an accelerator. The research consists of three basic parts: (a) continuously monitoring the conditioning of the three different types of beam pipe over both time and absorbed electrons (b) measurement of the characteristics of the surrounding magnetic fields in the Main Injector in order to better relate actual data observed in the Main Injector with that of simulations (c) measurement of the energy spectrum of the electron cloud signals using retarding field analyzers in all three types of beam pipe.

  9. Elastic-plastic dynamic behavior of guard pipes due to sudden opening of longitudinal cracks in the inner pipe and crash to the guard pipe wall

    International Nuclear Information System (INIS)

    Theuer, E.; Heller, M.

    1979-01-01

    Integrity of guard pipes is an important parameter in the design of nuclear steam supply systems. A guard pipe shall withstand all kinds of postulated inner pipe breaks without failure. Sudden opening of a crack in the inner pipe and crash of crack borders to the guard pipe wall represent a shock problem where complex phenomena of dynamic plastification as well as dynamic behavior of the entire system have to be taken in consideration. The problem was analyzed by means of Finite Element computation using the general purpose program MARC. Equation of motion was resolved by direct integration using the Newmark β-operator. Analysis shows that after 1,2 m sec crack borders touch the guard pipe wall for the first time. At this moment a considerable amount of local plastification appears in the inner pipe wall, while the guard pipe is nearly unstressed. After initial touching, the crack borders begin to slip along the guard pipe wall. Subsequently, a short withdrawal of the crack borders and a new crash occur, while the inner pipe rolls along the guard pipe wall. The analysis procedure described is suitable for designing numerous guard pipe geometries as well as U-Bolt restraint systems which have to withstand high-energy pipe rupture impact. (orig.)

  10. Characterization of radioactive contamination inside pipes with the Pipe Explorer trademark system

    International Nuclear Information System (INIS)

    Kendrick, D.T.; Cremer, C.D.; Lowry, W.; Cramer, E.

    1995-01-01

    The U.S. Department of Energy's nuclear facility decommissioning program needs to characterize radiological contamination inside piping systems before the pipe can be recycled, remediated, or disposed. Science and Engineering associates, Inc. under contract with the DOE Morgantown Energy Technology Center has developed and demonstrated the Pipe Explorer trademark system, which uses an inverting membrane to transport various characterization sensors into pipes. The basic process involves inverting (turning inside out) a tubular impermeable membrane under air pressure. A characterization sensor is towed down the interior of the pipe by the membrane. Advantages of this approach include the capability of deploying through constrictions in the pipe, around 90 degrees bends, vertically up and down, and in slippery conditions. Because the detector is transported inside the membrane (which is inexpensive and disposable), it is protected from contamination, which eliminates cross-contamination. Characterization sensors that have been demonstrated with the system thus far include: gamma detectors, beta detectors, video cameras, and pipe locators. Alpha measurement capability is currently under development. A remotely operable Pipe Explorer trademark system has been developed and demonstrated for use in DOE facilities in the decommissioning stage. The system is capable of deployment in pipes as small as 2-inch-diameter and up to 250 feet long. This paper describes the technology and presents measurement results of a field demonstration conducted with the Pipe Explorer trademark system at a DOE site. These measurements identify surface activity levels of U-238 contamination as a function of location in drain lines. Cost savings to the DOE of approximately $1.5 million dollars were realized from this one demonstration

  11. Solar heating pipe

    Energy Technology Data Exchange (ETDEWEB)

    Hinson-Rider, G.

    1977-10-04

    A fluid carrying pipe is described having an integral transparent portion formed into a longitudinally extending cylindrical lens that focuses solar heat rays to a focal axis within the volume of the pipe. The pipe on the side opposite the lens has a heat ray absorbent coating for absorbing heat from light rays that pass through the focal axis.

  12. Reliability of piping system components. Volume 4: The pipe failure event database

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, R; Erixon, S [Swedish Nuclear Power Inspectorate, Stockholm (Sweden); Tomic, B [ENCONET Consulting GmbH, Vienna (Austria); Lydell, B [RSA Technologies, Visat, CA (United States)

    1996-07-01

    Available public and proprietary databases on piping system failures were searched for relevant information. Using a relational database to identify groupings of piping failure modes and failure mechanisms, together with insights from published PSAs, the project team determined why, how and where piping systems fail. This report represents a compendium of technical issues important to the analysis of pipe failure events, and statistical estimation of failure rates. Inadequacies of traditional PSA methodology are addressed, with directions for PSA methodology enhancements. A `data driven and systems oriented` analysis approach is proposed to enable assignment of unique identities to risk-significant piping system component failure. Sufficient operating experience does exist to generate quality data on piping failures. Passive component failures should be addressed by today`s PSAs to allow for aging analysis and effective, on-line risk management. 42 refs, 25 figs.

  13. Reliability of piping system components. Volume 4: The pipe failure event database

    International Nuclear Information System (INIS)

    Nyman, R.; Erixon, S.; Tomic, B.; Lydell, B.

    1996-07-01

    Available public and proprietary databases on piping system failures were searched for relevant information. Using a relational database to identify groupings of piping failure modes and failure mechanisms, together with insights from published PSAs, the project team determined why, how and where piping systems fail. This report represents a compendium of technical issues important to the analysis of pipe failure events, and statistical estimation of failure rates. Inadequacies of traditional PSA methodology are addressed, with directions for PSA methodology enhancements. A 'data driven and systems oriented' analysis approach is proposed to enable assignment of unique identities to risk-significant piping system component failure. Sufficient operating experience does exist to generate quality data on piping failures. Passive component failures should be addressed by today's PSAs to allow for aging analysis and effective, on-line risk management. 42 refs, 25 figs

  14. Large-bore pipe decontamination

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1998-01-01

    The decontamination and decommissioning (D and D) of 1200 buildings within the US Department of Energy-Office of Environmental Management (DOE-EM) Complex will require the disposition of miles of pipe. The disposition of large-bore pipe, in particular, presents difficulties in the area of decontamination and characterization. The pipe is potentially contaminated internally as well as externally. This situation requires a system capable of decontaminating and characterizing both the inside and outside of the pipe. Current decontamination and characterization systems are not designed for application to this geometry, making the direct disposal of piping systems necessary in many cases. The pipe often creates voids in the disposal cell, which requires the pipe to be cut in half or filled with a grout material. These methods are labor intensive and costly to perform on large volumes of pipe. Direct disposal does not take advantage of recycling, which could provide monetary dividends. To facilitate the decontamination and characterization of large-bore piping and thereby reduce the volume of piping required for disposal, a detailed analysis will be conducted to document the pipe remediation problem set; determine potential technologies to solve this remediation problem set; design and laboratory test potential decontamination and characterization technologies; fabricate a prototype system; provide a cost-benefit analysis of the proposed system; and transfer the technology to industry. This report summarizes the activities performed during fiscal year 1997 and describes the planned activities for fiscal year 1998. Accomplishments for FY97 include the development of the applicable and relevant and appropriate regulations, the screening of decontamination and characterization technologies, and the selection and initial design of the decontamination system

  15. Experimental investigation on a pulsating heat pipe with hydrogen

    International Nuclear Information System (INIS)

    Deng, H R; Liu, Y M; Ma, R F; Han, D Y; Gan, Z H; Pfotenhauer, J M

    2015-01-01

    The pulsating heat pipe (PHP) has been increasingly studied in cryogenic application, for its high transfer coefficient and quick response. Compared with Nb 3 Sn and NbTi, MgB 2 whose critical transformation temperature is 39 K, is expected to replace some high-temperature superconducting materials at 25 K. In order to cool MgB 2 , this paper designs a Hydrogen Pulsating Heat Pipe, which allows a study of applied heat, filling ratio, turn number, inclination angle and length of adiabatic section on the thermal performance of the PHP. The thermal performance of the hydrogen PHP is investigated for filling ratios of 35%, 51%, 70% at different heat inputs, and provides information regarding the starting process is received at three filling ratios. (paper)

  16. Development of Pipe Holding Mechanism for Pipe Inspection Robot Using Flexible Pneumatic Cylinder

    Directory of Open Access Journals (Sweden)

    Choi Kyujun

    2016-01-01

    Full Text Available A pipe inspection robot is useful to reduce the inspection cost. In the previous study, a novel pipe inspection robot using a flexible pneumatic cylinder that can move forward along to the pipe by changing the robot’s body naturally was proposed and tested. In this paper, to improve its mobility for a corner of a pipe, the thin pipe holding mechanism using pneumatic bellows was proposed and tested. As a result of its driving test, the holding performance of the mechanism was confirmed.

  17. Piping reliability model development, validation and its applications to light water reactor piping

    International Nuclear Information System (INIS)

    Woo, H.H.

    1983-01-01

    A brief description is provided of a three-year effort undertaken by the Lawrence Livermore National Laboratory for the piping reliability project. The ultimate goal of this project is to provide guidance for nuclear piping design so that high-reliability piping systems can be built. Based on the results studied so far, it is concluded that the reliability approach can undoubtedly help in understanding not only how to assess and improve the safety of the piping systems but also how to design more reliable piping systems

  18. Numerical and experimental investigation of leaks in viscoelastic pressurized pipe flow

    Directory of Open Access Journals (Sweden)

    S. Meniconi

    2013-02-01

    Full Text Available This paper extends the analysis concerning the importance in numerical models of unsteady friction and viscoelasticity to transients in plastic pipes with an external flow due to a leak. In fact recently such a benchmarking analysis has been executed for the cases of a constant diameter pipe (Duan et al., 2010, a pipe with a partially closed in-line valve (Meniconi et al., 2012a, and a pipe with cross-section changes in series (Meniconi et al., 2012b. Tests are based on laboratory experiments carried out at the Water Engineering Laboratory (WEL of the University of Perugia, Italy, and the use of different numerical models. The results show that it is crucial to take into account the viscoelasticity to simulate the main characteristics of the examined transients.

  19. Lingon sa Iskolarsyip sa Dulaan (1948-2007 Looking Back on Theater Scholarship (1948-2007

    Directory of Open Access Journals (Sweden)

    Apolonio B. Chua

    2012-12-01

    Full Text Available From 1948 to 2007, the academic community produced about a hundred titles of theses and dissertations on drama and theater, or made use of data from drama and theater for larger spheres of studies. The current article looked into identifying trends and points of emphasis, as the researches and studies progressed through roughly half a century of research production in the academic setting. Inductive in approach and tentative and exploratory in its analysis, the study identified four trends and points of emphasis in research production. In the fifties and sixties, the emphasis was more on studying the play text or drama; studies veered towards a literary reading and orientation. Eventually, this trend gave way to studying the larger phenomenon of mounting, and the mise en scéne and the spectator became additional units of concern for research. Studies began to have sections on props, costumes, and staging techniques. In the eighties, a larger concern for looking at theater as social production followed. Participant observation, field work and ethnography gave equal emphasis on the social context of theater. Marxism and other perspectives from the social sciences framed theater studies then; correlations between theater and society became useful. Towards the last decade of the century, theater studies aimed at a more conceptual approach, emphasizing core concepts like panata and other related or equivalent terms, elevating and defining the study of theater as a study of culture itself. Gamit ang mahigit sa sandaang tesis at disertasyon hinggil sa dula at dulaan o sinasangkot ang mga ito na lumabas sa akademya mula 1948 hanggang 2007, kapwa sa Unibersidad ng Pilipinas at sa iba pa, nilayon ng “Lingon sa Iskolarsyip sa Dulaan (1948-2007” na pulsuhan ang pangkalahatang daloy, tutok, tunguhin o kalakaran sa pagdadala ng mga pag-aaral. Panimula at exploratory sa inductive nitong lapat, nakatukoy ang pag-aaral ng apat na sapit o tutok sa daloy ng

  20. 46 CFR 76.15-15 - Piping.

    Science.gov (United States)

    2010-10-01

    ... outside against corrosion unless specifically approved otherwise by the Commandant. (d) A pressure relief... pressure of not less than 6,000 p.s.i. (b) All piping, in nominal sizes not over 3/4 inch, shall be at... necessary, protected against injury. (g) Drains and dirt traps shall be fitted where necessary to prevent...

  1. Letramento funcional em saúde: reflexões e conceitos sobre seu impacto na interação entre usuários, profissionais e sistema de saúde

    Directory of Open Access Journals (Sweden)

    Maria da Penha Baião Passamai

    2012-06-01

    Full Text Available Letramento funcional em saúde (LFS é o grau pelo qual os indivíduos têm a capacidade para obter, processar e entender informações básicas e serviços necessários para a tomada de decisões adequadas em saúde. O tema preocupa pesquisadores/profissionais da saúde/formuladores de políticas públicas. Sua natureza interdisciplinar, relacional e interacional indica que o LFS sofre a influência dos sistemas de saúde/educacional, mídia, família, ambiente de trabalho/comunidade/decisão política. Analisam-se conceitos de LFS versus interação usuários-profissionais-sistema de saúde, norteando-se pelas questões: Em que consiste o LFS? Em que medida interfere na comunicação entre usuários, profissionais e sistema de saúde? Quais são suas consequências na saúde pública? Medidas para elevação do LFS devem melhorar as competências individuais e serviços de saúde humanizados, aperfeiçoando suas comunicações, escritas/orais, satisfazendo as necessidades/habilidades dos usuários.

  2. A participação do enfermeiro de saúde pública na saúde familiar

    Directory of Open Access Journals (Sweden)

    Zélia Sena Costa

    1986-09-01

    Full Text Available As autoras partem do pressuposto de que o avanço da epidemiologia tem demonstrado que muitas enfermidades estão associadas a determinadas estruturas sociais. Face a um enfoque científico, humanístico e personalizado, o Enfermeiro tem conquistado um papel de destaque junto à família, uma vez que este grupo social se constitui em uma via estratégica para utilização de parâmetros psicossocias tendo em vista a função básica de ajuda e apoio. Considerando que a contribuição do Enfermeiro de Saúde Pública é de vital importância para a melhoria do nível de saúde familiar, concluem que existe uma necessidade premente da aplicação adequada do Processo de Enfermagem a nível familiar, propondo a inserção da concepção - unidade familiar - como princípio básico da Assistência de Enfermagem.

  3. Hot Leg Piping Materials Issues

    International Nuclear Information System (INIS)

    V. Munne

    2006-01-01

    With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the space nuclear power plant (SNPP) for Project Prometheus (References a and b) the reactor outlet piping was recognized to require a design that utilizes internal insulation (Reference c). The initial pipe design suggested ceramic fiber blanket as the insulation material based on requirements associated with service temperature capability within the expected range, very low thermal conductivity, and low density. Nevertheless, it was not considered to be well suited for internal insulation use because its very high surface area and proclivity for holding adsorbed gases, especially water, would make outgassing a source of contaminant gases in the He-Xe working fluid. Additionally, ceramic fiber blanket insulating materials become very friable after relatively short service periods at working temperatures and small pieces of fiber could be dislodged and contaminate the system. Consequently, alternative insulation materials were sought that would have comparable thermal properties and density but superior structural integrity and greatly reduced outgassing. This letter provides technical information regarding insulation and materials issues for the Hot Leg Piping preconceptual design developed for the Project Prometheus space nuclear power plant (SNPP)

  4. Oscillating heat pipes

    CERN Document Server

    Ma, Hongbin

    2015-01-01

    This book presents the fundamental fluid flow and heat transfer principles occurring in oscillating heat pipes and also provides updated developments and recent innovations in research and applications of heat pipes. Starting with fundamental presentation of heat pipes, the focus is on oscillating motions and its heat transfer enhancement in a two-phase heat transfer system. The book covers thermodynamic analysis, interfacial phenomenon, thin film evaporation,  theoretical models of oscillating motion and heat transfer of single phase and two-phase flows, primary  factors affecting oscillating motions and heat transfer,  neutron imaging study of oscillating motions in an oscillating heat pipes, and nanofluid’s effect on the heat transfer performance in oscillating heat pipes.  The importance of thermally-excited oscillating motion combined with phase change heat transfer to a wide variety of applications is emphasized. This book is an essential resource and learning tool for senior undergraduate, gradua...

  5. Damping in LMFBR pipe systems

    International Nuclear Information System (INIS)

    Anderson, M.J.; Barta, D.A.; Lindquist, M.R.; Renkey, E.J.; Ryan, J.A.

    1983-06-01

    LMFBR pipe systems typically utilize a thicker insulation package than that used on water plant pipe systems. They are supported with special insulated pipe clamps. Mechanical snubbers are employed to resist seismic loads. Recent laboratory testing has indicated that these features provide significantly more damping than presently allowed by Regulatory Guide 1.61 for water plant pipe systems. This paper presents results of additional in-situ vibration tests conducted on FFTF pipe systems. Pipe damping values obtained at various excitation levels are presented. Effects of filtering data to provide damping values at discrete frequencies and the alternate use of a single equivalent modal damping value are discussed. These tests further confirm that damping in typical LMFBR pipe systems is larger than presently used in pipe design. Although some increase in damping occurred with increased excitation amplitude, the effect was not significant. Recommendations are made to use an increased damping value for both the OBE and DBE seismic events in design of LMFBR pipe systems

  6. 48 CFR 3028.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Administration. 3028.106 Section 3028.106 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY... 3028.106 Administration. ...

  7. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1994-01-01

    It is approximately 10 years since the Third Edition of Heat Pipes was published and the text is now established as the standard work on the subject. This new edition has been extensively updated, with revisions to most chapters. The introduction of new working fluids and extended life test data have been taken into account in chapter 3. A number of new types of heat pipes have become popular, and others have proved less effective. This is reflected in the contents of chapter 5. Heat pipes are employed in a wide range of applications, including electronics cooling, diecasting and injection mo

  8. Direito à saúde e saneamento básico na estratégia saúde da família no Complexo do Alemão = Right to health and basic sanitation in health strategy to the family in “Complexo do Alemão”

    Directory of Open Access Journals (Sweden)

    Simony Costa Oliveira

    2010-07-01

    Full Text Available Este artigo surge o interesse de estimular a reflexão sobre as possibilidades da garantia do direito ao saneamento básico no Complexo do Alemão - Rio de Janeiro, Estado do Rio de Janeiro a partir da Estratégia da Saúde da Família (ESF, na medida em que seentende o direito ao saneamento básico intimamente integrado ao direito à saúde. O estudo se propôs identificar a percepção dos profissionais que atuam na Unidade de Saúde da Família (USF Nova Brasília sobre o direito a saneamento básico, analisar a relação entresaneamento básico e direito à saúde para esses profissionais e discutir a utilização da Ficha A, na coleta de dados sobre as condições de infraestrutura sanitária dos moradores daquela região. Como resultado, encontra-se que esta discussão ainda é periférica dentro das equipes da ESF local e que a associação que essas fazem entre saneamento básico e saúde corresponde ainda a uma visão reducionista, que se expressa numa prática pouco propositivaem matéria de intervenções substanciais no acesso ao saneamento. Concluí-se que a ESF precisa (re pensar suas propostas e práticas, a partir de suas próprias contradições, entre elas, sua omissão perante o desafio de lutar pela garantia do direito à saúde e saneamentobásico nos territórios onde atua.This article results from the interest in stimulating the discussion on the possibilities of guaranteeing the right to basic sanitation, in a community located in “Complexo do Alemão” – Rio de Janeiro, Rio de Janeiro State, from the Family Health Strategy (FHS insofar as we understand the right to basic sanitation as closely integrated with the right to health. This article proposed to identify the perception on the right to basic sanitation of professionals working in the Nova Brasília FHS, to analyze the relation between basic sanitation and right to health through these professionals, and discuss the use of Form A in gathering data about the

  9. Gripe Suína: Saúde em destaque

    Directory of Open Access Journals (Sweden)

    HELOÍZA FELTRIN BANDEIRA

    2009-05-01

    Full Text Available B; font-size: small;">B; font-size: small;">

    O texto tem por objetivo analisar alguns

    fatos ligados à crise mundial na saúde causada pelo

    virus da Influenza A.

  10. An in-pipe mobile micromachine using fluid power. A mechanism adaptable to pipe diameters

    International Nuclear Information System (INIS)

    Yoshida, Kazuhiro; Yokota, Shinichi; Takahashi, Ken

    2000-01-01

    To realize micro maintenance robots for small diameter pipes of nuclear reactors and so on, high power in-pipe mobile micromachines have been required. The authors have proposed the bellows microactuator using fluid power and have tried to apply the actuators to in-pipe mobile micromachines. In the previous papers, some inchworm mobile machine prototypes with 25 mm in diameter are fabricated and the traveling performances are experimentally investigated. In this paper, to miniaturize the in-pipe mobile machine and to make it adaptable to pipe diameters, firstly, a simple rubber-tube actuator constrained with a coil-spring is proposed and the static characteristics are investigated. Secondly, a supporting mechanism which utilizes a toggle mechanism and is adaptable to pipe diameters is proposed and the supporting forces are investigated. Finally, an in-pipe mobile micromachine for pipe with 4 - 5 mm in diameter is fabricated and the maximum traveling velocity of 7 mm/s in both ahead and astern movements is experimentally verified. (author)

  11. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Chapter 3, July 2017 3-5 Table 3-4. Constant-Bandwidth FM Subcarrier Channels Frequency Criteria\\Channels: A B C D E F G H Deviation ...Telemetry Standards , RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms...Frequency Division Multiplexing Telemetry Standards ................................ 3-1 3.1 General

  12. 46 CFR 61.15-10 - Liquefied-petroleum-gas piping for heating and cooking.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Liquefied-petroleum-gas piping for heating and cooking. 61.15-10 Section 61.15-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE... piping for heating and cooking. (a) Leak tests as described in paragraph (b) of this section shall be...

  13. Necessidades de saúde comuns aos idosos: efetividade na oferta e utilização em atenção básica à saúde

    Directory of Open Access Journals (Sweden)

    Piccini Roberto Xavier

    2006-01-01

    Full Text Available A efetividade na oferta de serviços básicos e sua utilização por idosos abordada no Estudo de Linha de Base do Proesf conduzido pela UFPel incluiu 41 municípios dos Estados de Alagoas, Paraíba, Pernambuco, Piauí e Rio Grande do Norte, Rio Grande do Sul e Santa Catarina. O delineamento transversal caracterizou a estrutura e o processo de trabalho de 234 UBS, 4.749 trabalhadores e 4.003 idosos. Os indicadores sociais revelaram pior comportamento na região Nordeste e nas comunidades do Programa Saúde da Família (PSF. A necessidade de cuidados domiciliares regulares, a prevalência de Hipertensão Arterial Sistêmica (HAS e de Diabetes Mellitus (DM foram elevadas. Metade dos serviços oferecia barreiras arquitetônicas. O uso de protocolos para o cuidado domiciliar foi pouco freqüente e a capacitação para o cuidado de HAS e DM alcançou a metade dos trabalhadores. Metade dos portadores de HAS e DM usaram a Unidade Básica de Saúde (UBS da área; praticamente todos usavam medicação, a metade obtinha a medicação na UBS e menos da metade participava das atividades de grupo na UBS. Perda de efetividade foi observada na oferta e na utilização de serviços. O desempenho do PSF foi melhor quando comparado ao modelo tradicional.

  14. Heat pipes and heat pipe exchangers for heat recovery systems

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Grakovich, L P; Kiselev, V G; Kurustalev, D K; Matveev, Yu

    1984-01-01

    Heat pipes and heat pipe exchangers are of great importance in power engineering as a means of recovering waste heat of industrial enterprises, solar energy, geothermal waters and deep soil. Heat pipes are highly effective heat transfer units for transferring thermal energy over large distance (tens of meters) with low temperature drops. Their heat transfer characteristics and reliable working for more than 10-15 yr permit the design of new systems with higher heat engineering parameters.

  15. DeSa News. No. 2, February 2006

    International Nuclear Information System (INIS)

    2006-02-01

    The international project on Evaluation and Demonstration of Safety during Decommissioning of Nuclear Facilities (DeSa Project) was launched in November 2004 with the aim of developing a harmonized methodology for the safety assessment of decommissioning activities, providing recommendations on a systematic regulatory review procedure and applying the graded approach in the development and review of safety assessments for decommissioning. Significant work has been accomplished since the first project meeting (1-5 November 2004) in the following main areas: a. Development of a draft Safety Report on Safety Assessment Methodologies for Decommissioning of Nuclear Facilities; b. Development of first draft documents on the Regulatory Review and Application of the Graded Approach to Safety Assessments for Decommissioning; c. Six nuclear facilities volunteered by Member States as candidates for the preparation of a selected number of test cases during Phase 2 of the DeSa Project; d. Presentation of the Project at three international events in Canada and USA; e. Promotion of the Project through the first DeSa newsletter and the Project website (http://wwwns.iaea.org/tech-areas/waste-safety/desa). The second DeSa Project meeting (17-21 October 2005) attracted forty-two experts from twenty-six countries with the aim to: - Review progress on the five DeSa Project working groups (WGs) [Assessment Framework and System Description, Hazard Analysis, Analysis of Results and Confidence Building, Regulatory Review and Graded Approach] activities; - Review the draft Safety Report on Safety Assessment Methodologies for Decommissioning of Nuclear Facilities, as revised by the Coordinating Group of the DeSa Project in June 2005; - Review progress and further develop recommendations on the regulatory review of safety assessments for decommissioning and the application of a graded approach to be used during the development and review of such assessments; - Develop the DeSa work plan

  16. Remediation System Evaluation, Northwest Pipe and Casing Site

    Science.gov (United States)

    The Northwest Pipe and Casing Site is located in Clackamas, Oregon, approximately 20 miles southeastof Portland. The site consists of approximately 53 acres, and has historically been divided into two parcels(Parcel A to the north and Parcel B to the..

  17. Perfil de medicamentos descartados pelos usuários do sistema único de saúde no município de Divinópolis-MG

    Directory of Open Access Journals (Sweden)

    André de Oliveira Baldoni

    2015-12-01

    O objetivo do estudo foi orientar profissionais e usuários do Sistema Único de Saúde (SUS sobre o descarte e armazenamento de medicamentos, além de identificar o perfil de medicamentos descartados, em Divinópolis, Minas Gerais. As quatro etapas do estudo foram desenvolvidas de Março a Dezembro de 2014, a saber: 1 a escolha de doze Unidades de Saúde (Unidade Básica de Saúde ou Estratégia de Saúde da Família; 2contato com a unidade de saúde para agendamento da palestra educativa; 3 realização da palestra e coleta dos medicamentos descartados; 4 Análise do perfil dos medicamentos coletados. Foram recolhidas 11.518 unidades de medicamentos, sendo 9.729 vencidos (84,5%. A forma farmacêutica mais encontrada foi o comprimido (95,2%. As classes farmacológicas mais coletadas foram os anti-hipertensivos (22,0%, hipoglicemiante oral (10,7% e antiagregante plaquetário (10,6%. Observou-se elevada frequência de medicamentos vencidos, o que evidencia a necessidade de estratégias educativas para pacientes e equipe de saúde.

  18. Pipe restraints for nuclear power plants

    International Nuclear Information System (INIS)

    Keever, R.E.; Broman, R.; Shevekov, S.

    1976-01-01

    A pipe restraint for nuclear power plants in which a support member is anchored on supporting surface is described. Formed in the support member is a semicylindrical wall. Seated on the semicylindrical wall is a ring-shaped pipe restrainer that has an inner cylindrical wall. The inner cylindrical wall of the pipe restrainer encircles the pressurized pipe. In a modification of the pipe restraint, an arched-shaped pipe restrainer is disposed to overlie a pressurized pipe. The ends of the arch-shaped pipe restrainer are fixed to support members, which are anchored in concrete or to a supporting surface. A strap depends from the arch-shaped pipe restrainer. The pressurized pipe is supported by the depending strap

  19. Remaining life case history studies for high energy piping systems using equivalent stress

    International Nuclear Information System (INIS)

    Cohn, M.J.

    1987-01-01

    As the development of plant life extension for high energy piping systems is progressing, conventional piping system design methodologies are also being reevaluated. Traditional guidelines such as American National Standard Institute/American Society of Mechanical Engineers B31.1 (ANSI/ASME) were developed for plants having design lives in the 25- to 30-year regime based upon relatively short-term base metal creep data. These guidelines use a simplified approach for the piping analysis. Two types of stress criteria must be satisfied. The first type is longitudinal plus torsion stress checks for several types of loading conditions versus the material allowable stresses. The second type is an independent minimum wall thickness check which considers the hoop stress versus the material allowable stress. Seven case histories have been evaluated to estimate the minimum piping system creep life based on the current ANSI/ASME B31.1 finite element type of analysis, which is a traditional approach, versus a multiaxial stress state type of analysis. In nearly every case, the equivalent stress methodology predicted significantly higher stresses. Consequently, the equivalent stress methodology resulted in 11 to 96% lower time to rupture values as compared to the values predicted using ANSI/ASME B31.1 stresses

  20. PSA-2, Stress Analysis, Thermal Expansion and Loads in Multi Anchor Piping System

    Energy Technology Data Exchange (ETDEWEB)

    Nickols, A N [Codes Coordinator, Atomics International, P. O. Box 309, Canoga Park, California 91304 (United States)

    1975-03-01

    1 - Description of problem or function: PSA2 computes the reactions and stresses caused by thermal expansion and loads in a multi-anchor piping system which may contain loops and may be partially restrained at any point in any direction. 2 - Method of solution: The linear equations for the statically indeterminate pipe system are set up by a generalization of Brock's matrix method. By a systematic use of linear transforms, the matrix of the system of linear equations can be obtained by incidence algebra in the form of a symmetric banded matrix. 2 - Restrictions on the complexity of the problem - Maximum of: 36 sections. 3 - Unusual features of the program - PSA2 takes into account: (a) elasticity of the attachment of the pipe to the foundation, (b) restraints on pipe displacements by anchors and intermediate partial constraints of linear type, (c) given constant forces and moments acting upon the pipe system, (d) thermal expansion, (e) any geometrical structure of the pipe system, (f) several cases of stressing per pipe system, and (g) both metric and English units.

  1. PSA-2, Stress Analysis, Thermal Expansion and Loads in Multi Anchor Piping System

    International Nuclear Information System (INIS)

    Nickols, A.N.

    1975-01-01

    1 - Description of problem or function: PSA2 computes the reactions and stresses caused by thermal expansion and loads in a multi-anchor piping system which may contain loops and may be partially restrained at any point in any direction. 2 - Method of solution: The linear equations for the statically indeterminate pipe system are set up by a generalization of Brock's matrix method. By a systematic use of linear transforms, the matrix of the system of linear equations can be obtained by incidence algebra in the form of a symmetric banded matrix. 2 - Restrictions on the complexity of the problem - Maximum of: 36 sections. 3 - Unusual features of the program - PSA2 takes into account: (a) elasticity of the attachment of the pipe to the foundation, (b) restraints on pipe displacements by anchors and intermediate partial constraints of linear type, (c) given constant forces and moments acting upon the pipe system, (d) thermal expansion, (e) any geometrical structure of the pipe system, (f) several cases of stressing per pipe system, and (g) both metric and English units

  2. Is it possible to assure structural integrity and demonstrate life extension of older nuclear piping systems built to ASA B31.1?

    International Nuclear Information System (INIS)

    Burr, T.K.; Hawkes, G.L.; Morton, D.K.; Pace, N.E.

    1990-01-01

    Among the issues associated with older non-commercial reactors and irradiation facilities are (a) whether plant system designs are adequate relative to current industry standards and (b) whether degradation due to system aging adversely challenges the required margins of safety. These issues are being addressed at the Advanced Test Reactor (ATR) as part of a continuous effort to assure that ATR plant systems and safety analyses are consistent with state-of-the-art technology, evolving industry standards, and lessons learned from industry experience (e.g., Three Mile Island and Chernobyl). This paper presents a methodology for reevaluating loop experiment facility piping systems relative to concepts contained in the current ASME Boiler and Pressure Vessel Code, Section 3 and Section 11. Insights gained on the challenges associated with reevaluating older piping systems for structural adequacy and life extension considerations are discussed. 14 refs., 3 figs

  3. Characterization of radioactive contamination inside pipes with the Pipe Explorer{sup trademark} system

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, C.D.; Lowry, W.; Cramer, E. [Science and Engineering Associates, Inc., Albuquerque, NM (United States)] [and others

    1995-10-01

    The U.S. Department of Energy`s nuclear facility decommissioning program needs to characterize radiological contamination inside piping systems before the pipe can be recycled, remediated, or disposed. Historically, this has been attempted using hand held survey instrumentation, surveying only the accessible exterior portions of pipe systems. Difficulty, or inability of measuring threshold surface contamination values, worker exposure, and physical access constraints have limited the effectiveness of this approach. Science and Engineering associates, Inc. under contract with the DOE Morgantown Energy Technology Center has developed and demonstrated the Pipe Explorer{trademark} system, which uses an inverting membrane to transport various characterization sensors into pipes. The basic process involves inverting (turning inside out) a tubular impermeable membrane under air pressure. A characterization sensor is towed down the interior of the pipe by the membrane.

  4. Study on pressure pulsation and piping vibration of complex piping of reciprocating compressor

    International Nuclear Information System (INIS)

    Xu Bin; Feng Quanke; Yu Xiaoling

    2008-01-01

    This paper presents a preliminary research on the piping vibration and pressure pulsation of reciprocating compressor piping system. On the basis of plane wave theory, the calculation of gas column natural frequency and pressure pulsation in complex pipelines is done by using the transfer matrix method and stiffness matrix method, respectively. With the discretization method of FEM, a mathematical model for calculating the piping vibration and stress of reciprocating compressor piping system is established, and proper boundary conditions are proposed. Then the structural modal and stress of the piping system are calculated with CAESAR II. The comparison of measured and calculated values found that the one dimensional wave equation can accurately calculate the natural frequency and pressure pulsation in gas column of piping system for reciprocating compressor. (authors)

  5. Abordagem profissional da violência familiar contra o idoso em uma unidade básica de saúde

    Directory of Open Access Journals (Sweden)

    Ana Claudia Nunes de Souza Wanderbroocke

    2013-12-01

    Full Text Available O presente artigo tem como objetivo descrever a abordagem profissional da violência familiar contra idosos em uma unidade básica de saúde (UBS. Trata-se de pesquisa qualitativa, com dados coletados por meio de observação participante com registro em diário de campo e entrevistas semiestruturadas. Participaram das entrevistas dez profissionais da UBS. Os dados foram analisados segundo o referencial da Grounded Theory e duas categorias foram discutidas: manejo profissional de situações de violência familiar contra o idoso e condições da UBS para atender a situações de violência familiar contra o idoso. Os dados apontam para dificuldades dos profissionais de identificar situações de violência e crenças relacionadas à impossibilidade de enfrentá-la. Em termos institucionais, os dados indicam fatores que desfavorecem a detecção e acompanhamento dos casos como a menor ênfase no trabalho interdisciplinar e rotinas voltadas para a saúde física. O estudo sugere a necessidade de oferecer aos profissionais oportunidade para a reflexão sobre violência e possibilidades de intervenção.

  6. Study on the essential variables for pipe outer surface irradiated laser stress improvement process (L-SIP). Development of pipe outer surface irradiated laser stress improvement process (L-SIP)

    International Nuclear Information System (INIS)

    Ohta, Takahiro; Kamo, Kazuhiko; Muroya, Itaru; Asada, Seiji; Nakamura, Yasuo

    2009-01-01

    The new process called L-SIP (outer surface irradiated Laser Stress Improvement Process) is developed to improve the tensile residual stress of the inner surface near the butt welded joints of pipes in the compression stress. The temperature gradient occurs in the thickness of pipes in heating the outer surface rapidly by laser beam. By the thermal expansion difference between the inner surface and the outer surface, the compression stress occurs near the inner surface of pipes. In this paper, the essential variables for L-SIP is studied by experimental and FEM analysis. The range of the essential variables for L-SIP, which are defined by thermo-elastic FEM analysis, are Tmax=550 - 650degC, L Q /√rh ≥ 3, W Q /√rh ≥ 1.7, and, 0.04 ≤ F 0 ≤ 0.10 where Tmax is maximum temperature on the monitor point of the outer surface, F 0 is k x τ 0 /h 2 , k is thermal diffusivity coefficient, τ 0 is the temperature rise time from 100degC to maximum temperature on the monitor point of the outer surface, W Q is τ 0 x v, υ is moving velocity, L Q is the uniform temperature length in the axial direction, h is thickness of the pipe, and r is average radius of the pipe. It is showed by thermo-elastic-plastic FEM analysis that the residual stresses near the inner surface of pipes are improved in 4 different size pipes under the same essential variables. L-SIP is actually applied to welding joints of 4B x Sch160 and 2B x Sch80 SUS304 type stainless steel pipes within the defined range of the essential variables. The measured welding residual stresses on the inner surface near the welding joints are tensile. The residual stresses on the inner surface change to compression in all joints by L-SIP. (author)

  7. Structural analysis program of plant piping system. Introduction of AutoPIPE V8i new feature. JSME PPC-class 2 piping code

    International Nuclear Information System (INIS)

    Motohashi, Kazuhiko

    2009-01-01

    After an integration with ADLPipe, AutoPIPE V8i (ver.9.1) became the structural analysis program of plant piping system featured with analysis capability for the ASME NB Class 1 and JSME PPC-Class 2 piping codes including ASME NC Class 2 and ASME ND Class 3. This article described analysis capability for the JSME PPC-Class 2 piping code as well as new general features such as static analysis up to 100 thermal, 10 seismic and 10 wind load cases including different loading scenarios and pipe segment edit function: join, split, reverse and re-order segments. (T. Tanaka)

  8. 48 CFR 2828.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Administration. 2828.106 Section 2828.106 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE General Contracting Requirements BONDS AND INSURANCE Bonds 2828.106 Administration. ...

  9. Promoção da saúde ocular e prevenção precoce de problemas visuais nos serviços de saúde pública

    Directory of Open Access Journals (Sweden)

    Ana Maria Girotti Sperandio

    1999-10-01

    Full Text Available OBJETIVO: Verificar o conhecimento, atitudes e práticas em relação às ações básicas de saúde ocular de pediatras e enfermeiros de serviços de saúde pública. MÉTODO: A população estudada constituiu-se de pediatras e enfermeiros que trabalhavam nos centros de saúde do Município de Campinas, SP - Brasil, e atuavam com crianças de 0 a 12 anos de idade. As informações sobre conhecimento, atitudes e práticas foram colhidas através de questionários (para os pediatras e de formulários (para os enfermeiros. RESULTADOS: A execução das ações básicas de saúde ocular em crianças não fazia parte da rotina de atividades dos pediatras e enfermeiros, provavelmente devido ao pouco conhecimento dessas ações. Dos 61 pediatras, 82,0% (50 e 91,0% dos 22 enfermeiros não souberam referir a idade em que se completa o desenvolvimento visual. Em relação à ambliopia, 86,8% (53 dos pediatras e 100,0% dos enfermeiros não souberam defini-la. CONCLUSÕES: A promoção da saúde ocular e a prevenção precoce de problemas visuais em crianças não representava uma prática constante desses profissionais vinculados aos serviços de saúde pública. Recomenda-se que se realize treinamentos e educação continuada na área de saúde ocular durante e após a formação universitária desses profissionais.

  10. Promoção da saúde ocular e prevenção precoce de problemas visuais nos serviços de saúde pública

    Directory of Open Access Journals (Sweden)

    Sperandio Ana Maria Girotti

    1999-01-01

    Full Text Available OBJETIVO: Verificar o conhecimento, atitudes e práticas em relação às ações básicas de saúde ocular de pediatras e enfermeiros de serviços de saúde pública. MÉTODO: A população estudada constituiu-se de pediatras e enfermeiros que trabalhavam nos centros de saúde do Município de Campinas, SP - Brasil, e atuavam com crianças de 0 a 12 anos de idade. As informações sobre conhecimento, atitudes e práticas foram colhidas através de questionários (para os pediatras e de formulários (para os enfermeiros. RESULTADOS: A execução das ações básicas de saúde ocular em crianças não fazia parte da rotina de atividades dos pediatras e enfermeiros, provavelmente devido ao pouco conhecimento dessas ações. Dos 61 pediatras, 82,0% (50 e 91,0% dos 22 enfermeiros não souberam referir a idade em que se completa o desenvolvimento visual. Em relação à ambliopia, 86,8% (53 dos pediatras e 100,0% dos enfermeiros não souberam defini-la. CONCLUSÕES: A promoção da saúde ocular e a prevenção precoce de problemas visuais em crianças não representava uma prática constante desses profissionais vinculados aos serviços de saúde pública. Recomenda-se que se realize treinamentos e educação continuada na área de saúde ocular durante e após a formação universitária desses profissionais.

  11. Saúde Ambiental: uma Análise dos Resultados das Conferências Nacionais de Meio Ambiente, Saúde e Saúde Ambiental

    Directory of Open Access Journals (Sweden)

    Maria Beatriz Maury de Carvalho

    2010-08-01

    Full Text Available A representação nas políticas públicas do conceito de saúde ambiental, como expressão do equilíbrio da rede de conexões entre a sociedade humana e a natureza é discutida neste trabalho, no intuito de demonstrar o status quo da saúde ambiental nas políticas públicas no país. Primeiro foi traçado o histórico da “ambientalização na saúde”, do conceito de saúde ambiental e da institucionalização das políticas ambientais e de saúde ambiental no âmbito dos Ministérios do Meio Ambiente e da Saúde. As interações entre as políticas de Saúde e de Meio Ambiente para a efetivação de uma Política Nacional de Saúde Ambiental e as intersecções dos resultados das Conferências Nacionais de Saúde, Meio Ambiente e Saúde Ambiental foram analisadas; concluindo- se com os avanços conseguidos pelos dois setores, os desafios para a articulação intersetorial e a participação social para a construção de políticas públicas de saúde ambiental.

  12. Water SA - Vol 36, No 1 (2010)

    African Journals Online (AJOL)

    Water SA. ... Phthalate ester plasticizers in freshwater systems of Venda, South Africa and potential health effects · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. O.S Fatoki, M Bornman, L Ravandhalala, L Chimuka, B Genthe, A Adeniyi.

  13. 48 CFR 1028.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Administration. 1028.106 Section 1028.106 Federal Acquisition Regulations System DEPARTMENT OF THE TREASURY GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds 1028.106 Administration. ...

  14. Risk evaluation of embedded, single-walled liquid low-level waste piping at Oak Ridge National Laboratory. ESD Publication 4315

    International Nuclear Information System (INIS)

    1994-10-01

    Four categories of liquid low-level radioactive waste (LLLW) systems are defined in the Federal Facility Agreement (FFA) for the Oak Ridge Reservation (ORR). Categories A and B are new and fully compliant existing systems, respectively: Category C is singly contained and must be removed from service, and Category D is inactive. The FFA requires that secondary containment and leak detection be provided for all Category A and B piping in the LLLW System at Oak Ridge National Laboratory (ORNL); however, as noted in the D2 revision of the secondary containment design demonstration report (DOE 1994), some sections of single-walled embedded piping in Category B underground vaults at three ORNL facilities do not meet this requirement. A risk evaluation was performed in order compare the potential radiation dose to a member of the public that could result from a postulated leak in the single-walled pipes with projected radiation exposure to the workers who would modify the piping to meet FFA requirements. The risk to human health from replacing segments of embedded, single-walled piping in the LLW system is higher than the risk of leaving the piping as it is

  15. Piping equipment; Materiel petrole

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This 'blue bible' of the perfect piping-man appeals to end-users of industrial facilities of the petroleum and chemical industries (purchase services, standardization, new works, maintenance) but also to pipe-makers and hollow-ware makers. It describes the characteristics of materials (carbon steels, stainless steels, alloyed steels, special alloys) and the dimensions of pipe elements: pipes, welding fittings, flanges, sealing products, forged steel fittings, forged steel valves, cast steel valves, ASTM standards, industrial valves. (J.S.)

  16. 48 CFR 228.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Administration. 228.106 Section 228.106 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds 228.106 Administration. ...

  17. 48 CFR 1228.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Administration. 1228.106 Section 1228.106 Federal Acquisition Regulations System DEPARTMENT OF TRANSPORTATION GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds and Other Financial Protections 1228.106 Administration. ...

  18. 48 CFR 828.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Administration. 828.106 Section 828.106 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds and Other Financial Protections 828.106 Administration. ...

  19. 48 CFR 428.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Administration. 428.106 Section 428.106 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds and Other Financial Protections 428.106 Administration. ...

  20. 48 CFR 1328.106 - Administration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Administration. 1328.106 Section 1328.106 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE GENERAL CONTRACTING REQUIREMENTS BONDS AND INSURANCE Bonds and Other Financial Protections 1328.106 Administration. ...

  1. Heat Pipes

    Science.gov (United States)

    1990-01-01

    Bobs Candies, Inc. produces some 24 million pounds of candy a year, much of it 'Christmas candy.' To meet Christmas demand, it must produce year-round. Thousands of cases of candy must be stored a good part of the year in two huge warehouses. The candy is very sensitive to temperature. The warehouses must be maintained at temperatures of 78-80 degrees Fahrenheit with relative humidities of 38- 42 percent. Such precise climate control of enormous buildings can be very expensive. In 1985, energy costs for the single warehouse ran to more than 57,000 for the year. NASA and the Florida Solar Energy Center (FSEC) were adapting heat pipe technology to control humidity in building environments. The heat pipes handle the jobs of precooling and reheating without using energy. The company contacted a FSEC systems engineer and from that contact eventually emerged a cooperative test project to install a heat pipe system at Bobs' warehouses, operate it for a period of time to determine accurately the cost benefits, and gather data applicable to development of future heat pipe systems. Installation was completed in mid-1987 and data collection is still in progress. In 1989, total energy cost for two warehouses, with the heat pipes complementing the air conditioning system was 28,706, and that figures out to a cost reduction.

  2. Ductile failure of pipes with defects under combined pressure and bending

    International Nuclear Information System (INIS)

    Darlaston, B.J.L.; Harrison, R.P.

    1977-01-01

    The main part of the experimental programme was carried out on 3.5'' diam. pipes with a wall thickness of 0.064''. Various lengths of defect were assessed but only two depths, 0.044'' and 0.060''. Some full penetration defect tests were carried out under bending loading. The defects were 0.012'' wide and nominally flat bottomed. The tensile properties of the pipes were determined by taking specimens from each of the tubes. The pipes were exposed to pressure only test, bending only test and combined bending and pressure test. The results are given in tables. The observations led to the postulation of a design rule relating to the effect of defect in pipes under combined internal pressure and bending. It applies only to ductile situations in which the mode of failure is by a collapse mechanism: If the failure of a pipe containing an axial defect occurs by plastic collapse then provided the bending moment does not exceed half that for collapse due to bending alone, it will have a negligible effect on the failure pressure. (J.B.)

  3. 47 CFR 19.735-106 - Interpretation and advisory service.

    Science.gov (United States)

    2010-10-01

    ... through the employee's supervisor to the General Counsel, who is the Commission's Designated Agency Ethics Official pursuant to the delegation of authority at 47 CFR 0.251(a). (b) At the time of an employee's... Section 19.735-106 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMPLOYEE RESPONSIBILITIES...

  4. 17 CFR 10.106 - Reconsideration; stay pending judicial review.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Reconsideration; stay pending... COMMISSION RULES OF PRACTICE Appeals to the Commission; Settlements § 10.106 Reconsideration; stay pending... operate to stay the effective date of the Commission's order. (b) Stay pending judicial appeal—(1...

  5. Subprogram Calculating The Distance Between Pipe And Plane For Automatic Piping System Design

    International Nuclear Information System (INIS)

    Satmoko, Ari

    2001-01-01

    DISTLNPL subprogram was created using Auto LISP software. This subprogram is planned to complete CAPD (Computer Aided Piping Design) software being developed. The CAPD works under the following method: suggesting piping system line and evaluating whether any obstacle allows the proposed line to be constructed. DISTLNPL is able to compute the distance between pipe and any equipment having plane dimension such as wall, platform, floors, and so on. The pipe is modeled by using a line representing its axis, and the equipment is modeled using a plane limited by some lines. The obtained distance between line and plane gives information whether the pipe crosses the equipment. In the case of crashing, the subprogram will suggest an alternative point to be passed by piping system. So far, DISTLNPL has not been able to be accessed by CAPD yet. However, this subprogram promises good prospect in modeling wall, platform, and floors

  6. 76 FR 13063 - Airworthiness Directives; EUROCOPTER FRANCE Model SA330F, SA330G, and SA330J Helicopters

    Science.gov (United States)

    2011-03-10

    ... Airworthiness Directives; EUROCOPTER FRANCE Model SA330F, SA330G, and SA330J Helicopters AGENCY: Federal... system and the pedals rocking forward. After investigation, it was determined that the Loctite bond on the ``tall pilot'' stop nut was damaged, most likely due to aging of the adhesive. The nut came loose...

  7. Thermal Performance and Operation Limit of Heat Pipe Containing Neutron Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Mo; Jeong, Yeong Shin; Kim, In Guk; Bang, In Choel [UNIST, Ulsan (Korea, Republic of)

    2015-05-15

    Recently, passive safety systems are under development to ensure the core cooling in accidents involving impossible depressurization such as station blackout (SBO). Hydraulic control rod drive mechanisms, passive auxiliary feedwater system (PAFS), Passive autocatalystic recombiner (PAR), and so on are types of passive safety systems to enhance the safety of nuclear power plants. Heat pipe is used in various engineering fields due to its advantages in terms of easy fabrication, high heat transfer rate, and passive heat transfer. Also, the various concepts associated with safety system and heat transfer using the heat pipe were developed in nuclear engineering field.. Thus, our group suggested the hybrid control rod which combines the functions of existing control rod and heat pipe. If there is significant temperature difference between active core and condenser, the hybrid control rod can shutdown the nuclear fission reaction and remove the decay heat from the core to ultimate heat sink. The unique characteristic of the hybrid control rod is the presence of neutron absorber inside the heat pipe. Many previous researchers studied the effect of parameters on the thermal performance of heat pipe. However, the effect of neutron absorber on the thermal performance of heat pipe has not been investigated. Thus, the annular heat pipe which contains B{sub 4}C pellet in the normal heat pipe was prepared and the thermal performance of the annular heat pipe was studied in this study. Hybrid control rod concept was developed as a passive safety system of nuclear power plant to ensure the safety of the reactor at accident condition. The hybrid control rod must contain the neutron absorber for the function as a control rod. So, the effect of neutron absorber on the thermal performance of heat pipe was experimentally investigated in this study. Temperature distributions at evaporator section of annular heat pipe were lower than normal heat pipe due to the larger volume occupied by

  8. Telemetry Standards, RCC Standard 106-17, Chapter 4, Pulse Code Modulation Standards

    Science.gov (United States)

    2017-07-01

    A-4 Appendix 4-B. Citations ...investigation can be found in a paper by J. L. Maury, Jr. and J. Styles , “Development of Optimum Frame Synchronization Codes for Goddard Space Flight Center...Standards, RCC Standard 106-17 Chapter 4, July 2017 B-1 APPENDIX 4-B Citations Aeronautical Radio, Inc. Mark 33 Digital Information Transfer

  9. Koherentas kustības uztvere skolas vecuma bērniem ar sašaurinātu vizuālās uztveres lauku

    OpenAIRE

    Gritāne, Andželika

    2017-01-01

    Maģistra darbs tika uzrakstīts latviešu valodā uz 40 lapām, darbs satur 24 attēlus, 8 tabulas un satur 28 atsauces uz literatūras avotiem. Darba mērķis: Noteikt koherentas kustības slieksni skolas vecuma bērniem ar sašaurinātu vizuālās uzmanības lauku. Metodika: Dalībnieki tika iedalīti divās grupās balstoties un nevārda atpazīšanas testa rezultātiem – grupa ar sašaurinātu vizuālās uztveres lauku un grupa ar attīstībai atbilstošu vizuālās uztveres lauka lielumu. Abu grupu dalībniekiem tika n...

  10. Pipe Crawler internal piping characterization system. Deactivation and decommissioning focus area. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    1998-02-01

    Pipe Crawler reg-sign is a pipe surveying system for performing radiological characterization and/or free release surveys of piping systems. The technology employs a family of manually advanced, wheeled platforms, or crawlers, fitted with one or more arrays of thin Geiger Mueller (GM) detectors operated from an external power supply and data processing unit. Survey readings are taken in a step-wise fashion. A video camera and tape recording system are used for video surveys of pipe interiors prior to and during radiological surveys. Pipe Crawler reg-sign has potential advantages over the baseline and other technologies in areas of cost, durability, waste minimization, and intrusiveness. Advantages include potentially reduced cost, potential reuse of the pipe system, reduced waste volume, and the ability to manage pipes in place with minimal disturbance to facility operations. Advantages over competing technologies include potentially reduced costs and the ability to perform beta-gamma surveys that are capable of passing regulatory scrutiny for free release of piping systems

  11. Telemetry Standards, RCC Standard 106-17, Annex A.1, Pulse Amplitude Modulation Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Annex A.1, July 2017 A.1-iii Acronyms dB decibel FM frequency modulation IF intermediate frequency PAM pulse amplitude...premodulation filter when employed. b. One-fifth of the intermediate frequency (IF) bandwidth (3 dB points) selected from the IF bandwidths listed in

  12. Pipe stress analysis on HCCR-TBS ancillary systems in conceptual design

    International Nuclear Information System (INIS)

    Ahn, Mu-Young; Cho, Seungyon; Lee, Eo Hwak; Park, Yi-Hyun; Lee, Youngmin

    2016-01-01

    Highlights: • Pipe stress is performed on Korean HCCR-TBS for the load combinations including seismic events. • The resultant stress meets the requirement of the design code & standard except one position where modification is needed. • The results gives useful information for the design evolution in the next desgin phase. - Abstract: Korean Helium Cooled Ceramic Reflector (HCCR) Test Blanket System (TBS) will be tested in ITER to demonstrate feasibility of the breeding blanket concept. The HCCR-TBS comprises Test Blanket Module (TBM) with associated shield, and ancillary systems located in various positions of ITER building. Currently, conceptual design for the HCCR-TBS is in progress. This paper presents pipe stress analysis results for the HCCR-TBS ancillary systems. The pipe stress analysis was performed in accordance with ASME B31.3 for major pipes of the Helium Cooling System (HCS) and the Coolant Purification System (CPS), which are operated in high pressure and temperature. The pipe stress for various load cases and load combinations were calculated. Operational pressure and temperature during plasma operation are applied as pressure load and thermal load, respectively. In addition seismic events were combined to investigate the code compliance for sustained load case and occasional load case. It was confirmed that the resultant stress meets the requirements of ASME B31.3 except one position in which it needs modification. These results give useful information for the next design phase, for example, nozzle loads for the component selection, the support design parameters, etc.

  13. Pipe stress analysis on HCCR-TBS ancillary systems in conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Mu-Young, E-mail: myahn74@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of); Lee, Eo Hwak [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Yi-Hyun; Lee, Youngmin [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    Highlights: • Pipe stress is performed on Korean HCCR-TBS for the load combinations including seismic events. • The resultant stress meets the requirement of the design code & standard except one position where modification is needed. • The results gives useful information for the design evolution in the next desgin phase. - Abstract: Korean Helium Cooled Ceramic Reflector (HCCR) Test Blanket System (TBS) will be tested in ITER to demonstrate feasibility of the breeding blanket concept. The HCCR-TBS comprises Test Blanket Module (TBM) with associated shield, and ancillary systems located in various positions of ITER building. Currently, conceptual design for the HCCR-TBS is in progress. This paper presents pipe stress analysis results for the HCCR-TBS ancillary systems. The pipe stress analysis was performed in accordance with ASME B31.3 for major pipes of the Helium Cooling System (HCS) and the Coolant Purification System (CPS), which are operated in high pressure and temperature. The pipe stress for various load cases and load combinations were calculated. Operational pressure and temperature during plasma operation are applied as pressure load and thermal load, respectively. In addition seismic events were combined to investigate the code compliance for sustained load case and occasional load case. It was confirmed that the resultant stress meets the requirements of ASME B31.3 except one position in which it needs modification. These results give useful information for the next design phase, for example, nozzle loads for the component selection, the support design parameters, etc.

  14. 15 CFR 200.106 - Publications.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Publications. 200.106 Section 200.106... FEES § 200.106 Publications. Publications provide the primary means of communicating the results of the... issues some fifteen categories of publications including three periodicals, ten non-periodicals series...

  15. 7 CFR 1924.106 - Location.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Location. 1924.106 Section 1924.106 Agriculture... CONSTRUCTION AND REPAIR Planning and Performing Site Development Work § 1924.106 Location. (a) General. It is... will not finance development on locations that adversely affect properties which are listed or are...

  16. 34 CFR 106.23 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Recruitment. 106.23 Section 106.23 Education... Discrimination on the Basis of Sex in Admission and Recruitment Prohibited § 106.23 Recruitment. (a) Nondiscriminatory recruitment. A recipient to which this subpart applies shall not discriminate on the basis of sex...

  17. 42 CFR 401.106 - Publication.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Publication. 401.106 Section 401.106 Public Health... GENERAL ADMINISTRATIVE REQUIREMENTS Confidentiality and Disclosure § 401.106 Publication. (a) Methods of publication. Materials required to be published under the provisions of The Freedom of Information Act, 5 U.S...

  18. 29 CFR 4.106 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true [Reserved] 4.106 Section 4.106 Labor Office of the Secretary of Labor LABOR STANDARDS FOR FEDERAL SERVICE CONTRACTS Application of the McNamara-O'Hara Service Contract Act Introductory § 4.106 [Reserved] Agencies Whose Contracts May Be Covered ...

  19. Pipe rupture test results; 4 inch pipe whip tests under BWR operational condition-clearance parameter experiments

    International Nuclear Information System (INIS)

    Ueda, Syuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kurihara, Ryoichi; Kato, Rokuro; Saito, Kazuo; Miyazono, Shohachiro

    1981-05-01

    The purpose of pipe rupture studies in JAERI is to perform the model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish the computational method for analyzing these phenomena. This report describes the experimental results of pipe whip on the pipe specimens of 4 inch in diameter under BWR condition on which the pressure is 6.77 MPa and the temperature is 285 0 C. The pipe specimens were 114.3 mm (4 inch) in diameter and 8.6 mm in thickness and 4500 mm in length. Four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and fabricated from type 304 stainless steel. The experimental parameter was the clearance (30, 50 and 100 mm). The dynamic strain behavior of the pipe specimen and the restraints was investigated by strain gages and their residual deformation was obtained by measuring marking points provided on their surface. The Pressure-time history in the pipe specimens was also obtained by pressure gages. The maximum pipe strain is caused near the restraints and increases with increase of the clearance. The experimental results of pipe whip tests indicate the effectiveness of pipe whip restraints. The ratio of absorbed strain energy of the pipe specimen to that of the restraints is nearly constant for different clearances at the overhang length of 400 mm. (author)

  20. 21 CFR 106.90 - Coding.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Coding. 106.90 Section 106.90 Food and Drugs FOOD... of Infant Formulas § 106.90 Coding. The manufacturer shall code all infant formulas in conformity with the coding requirements that are applicable to thermally processed low-acid foods packaged in...

  1. 34 CFR 106.32 - Housing.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Housing. 106.32 Section 106.32 Education Regulations of... Discrimination on the Basis of Sex in Education Programs or Activities Prohibited § 106.32 Housing. (a) Generally... fees or requirements, or offer different services or benefits related to housing, except as provided in...

  2. 34 CFR 106.51 - Employment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Employment. 106.51 Section 106.51 Education Regulations... Discrimination on the Basis of Sex in Employment in Education Programs or Activities Prohibited § 106.51 Employment. (a) General. (1) No person shall, on the basis of sex, be excluded from participation in, be...

  3. A musicoterapia na sala de espera de uma unidade básica de saúde: assistência, autonomia e protagonismo

    Directory of Open Access Journals (Sweden)

    Adriana de Freitas Pimentel

    Full Text Available O acolhimento é uma diretriz da Política Nacional de Humanização que concretiza os princípios básicos do Sistema Nacional de Saúde (SUS. A sala de espera insere-se na discussão teórica e prática do acolhimento. A necessidade de ações que fomentem a implantação desta diretriz inspirou a realização da primeira pesquisa sobre a musicoterapia em uma Unidade Básica de Saúde (UBS, cujo objetivo foi contribuir para o acolhimento com a prática musicoterápica na sala de espera, por meio da categoria operacional - espera. A metodologia incluiu entrevistas e atividades musicoterápicas. Resultados revelam a indignação dos usuários quanto à longa espera e a transformação do local em um espaço de assistência, autonomia e protagonismo. A pesquisa aponta a Musicoterapia como estratégia para ser difundida em outras UBS.

  4. A musicoterapia na sala de espera de uma unidade básica de saúde: assistência, autonomia e protagonismo

    Directory of Open Access Journals (Sweden)

    Adriana de Freitas Pimentel

    2011-09-01

    Full Text Available O acolhimento é uma diretriz da Política Nacional de Humanização que concretiza os princípios básicos do Sistema Nacional de Saúde (SUS. A sala de espera insere-se na discussão teórica e prática do acolhimento. A necessidade de ações que fomentem a implantação desta diretriz inspirou a realização da primeira pesquisa sobre a musicoterapia em uma Unidade Básica de Saúde (UBS, cujo objetivo foi contribuir para o acolhimento com a prática musicoterápica na sala de espera, por meio da categoria operacional - espera. A metodologia incluiu entrevistas e atividades musicoterápicas. Resultados revelam a indignação dos usuários quanto à longa espera e a transformação do local em um espaço de assistência, autonomia e protagonismo. A pesquisa aponta a Musicoterapia como estratégia para ser difundida em outras UBS.

  5. Synergistic streptococcal phage λSA2 and B30 endolysins kill streptococci in cow milk and in a mouse model of mastitis.

    Science.gov (United States)

    Schmelcher, Mathias; Powell, Anne M; Camp, Mary J; Pohl, Calvin S; Donovan, David M

    2015-10-01

    Bovine mastitis results in billion dollar losses annually in the USA alone. Streptococci are among the most relevant causative agents of this disease. Conventional antibiotic therapy is often unsuccessful and contributes to development of antibiotic resistance. Bacteriophage endolysins represent a new class of antimicrobials against these bacteria. In this work, we characterized the endolysins (lysins) of the streptococcal phages λSA2 and B30 and evaluated their potential as anti-mastitis agents. When tested in vitro against live streptococci, both enzymes exhibited near-optimum lytic activities at ionic strengths, pH, and Ca(2+) concentrations consistent with cow milk. When tested in combination in a checkerboard assay, the lysins were found to exhibit strong synergy. The λSA2 lysin displayed high activity in milk against Streptococcus dysgalactiae (reduction of CFU/ml by 3.5 log units at 100 μg/ml), Streptococcus agalactiae (2 log), and Streptococcus uberis (4 log), whereas the B30 lysin was less effective. In a mouse model of bovine mastitis, both enzymes significantly reduced intramammary concentrations of all three streptococcal species (except for B30 vs. S. dysgalactiae), and the effects on mammary gland wet weights and TNFα concentrations were consistent with these findings. Unexpectedly, the synergistic effect determined for the two enzymes in vitro was not observed in the mouse model. Overall, our results illustrate the potential of endolysins for treatment of Streptococcus-induced bovine mastitis.

  6. South African Medical Journal - Vol 106, No 4 (2016)

    African Journals Online (AJOL)

    A multifaceted hospital-wide intervention increases hand hygiene compliance · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. B Patel, H Engelbrecht, H McDonald, V Morris, W Smythe, 335-341. http://dx.doi.org/10.7196/SAMJ.2016.v106i4.10671 ...

  7. Reactor Primary Coolant System Pipe Rupture Study. Progress report No. 32, July--December 1974

    International Nuclear Information System (INIS)

    1975-03-01

    The pipe rupture study is designed to extend the understanding of failure-causing mechanisms and to provide improved capability for evaluating reactor piping systems to minimize the probability of failures. Following a detailed review to determine the effort most needed to improve nuclear system piping (Phase I), analytical and experimental efforts (Phase II) were started in 1965. This progress report summarizes the recent accomplishments of a broad program in (a) basic fatigue studies focused on Elastic/Plastic ASME Code Design Rules, (b) at-reactor tests of the effect of primary coolant environment on the fatigue behavior of piping steels, and (c) studies directed at quantifying weld sensitization in T-304 stainless steel. (auth)

  8. Health literacy of older people in primary care Alfabetización en salud de personas ancianas en la atención básica Alfabetização em saúde de pessoas idosas na atenção básica

    Directory of Open Access Journals (Sweden)

    Lisiane Manganelli Girardi Paskulin

    2012-01-01

    entre los mismos. Los resultados apoyaron la planificación, implementación y perfeccionamiento de las acciones de educación en salud con ancianos en la atención básica de la salud.OBJETIVO: Analisar como pessoas idosas vinculadas a grupos de educação em saúde de uma unidade básica de saúde buscam, compreendem e partilham informações a fim de manter e promover a saúde ao longo da vida. MÉTODOS: Pesquisa descritiva de caráter qualitativo, realizada com 30 idosos ligados a três grupos de educação em saúde, no segundo semestre de 2009, cuja coleta de informações deu-se por meio de entrevistas e análise temática, com o apoio do software NVivo. RESULTADOS: Foram elaboradas cinco categorias de análise - interesse/preocupação em saúde; busca, compreensão partilha e repercussão das informações para o idoso. CONCLUSÕES: A alfabetização em saúde nos grupos desenvolveu-se em uma perspectiva individual, voltada à prevenção e tratamento de danos, respeitando a trajetória e conhecimento dos sujeitos e valorizando possibilidades de trocas entre os mesmos. Os resultados apoiarão o planejamento, implementação e aprimoramento de ações de educação em saúde com idosos na atenção básica à saúde.

  9. Pipe support program at Pickering

    International Nuclear Information System (INIS)

    Sahazizian, L.A.; Jazic, Z.

    1997-01-01

    This paper describes the pipe support program at Pickering. The program addresses the highest priority in operating nuclear generating stations, safety. We present the need: safety, the process: managed and strategic, and the result: assurance of critical piping integrity. In the past, surveillance programs periodically inspected some systems, equipment, and individual components. This comprehensive program is based on a managed process that assesses risk to identify critical piping systems and supports and to develop a strategy for surveillance and maintenance. The strategy addresses all critical piping supports. Successful implementation of the program has provided assurance of critical piping and support integrity and has contributed to decreasing probability of pipe failure, reducing risk to worker and public safety, improving configuration management, and reducing probability of production losses. (author)

  10. Heat pipe applications workshop report

    International Nuclear Information System (INIS)

    Ranken, W.A.

    1978-04-01

    The proceedings of the Heat Pipe Applications Workshop, held at the Los Alamos Scientific Laboratory October 20-21, 1977, are reported. This workshop, which brought together representatives of the Department of Energy and of a dozen industrial organizations actively engaged in the development and marketing of heat pipe equipment, was convened for the purpose of defining ways of accelerating the development and application of heat pipe technology. Recommendations from the three study groups formed by the participants are presented. These deal with such subjects as: (1) the problem encountered in obtaining support for the development of broadly applicable technologies, (2) the need for applications studies, (3) the establishment of a heat pipe technology center of excellence, (4) the role the Department of Energy might take with regard to heat pipe development and application, and (5) coordination of heat pipe industry efforts to raise the general level of understanding and acceptance of heat pipe solutions to heat control and transfer problems

  11. Metabolism and dosimetry of 106Ru inhaled as 106RuO4 by beagle dogs

    International Nuclear Information System (INIS)

    Snipes, M.B.

    1981-01-01

    This report provides metabolism and dosimetry data for inhaled ruthenium developed from studies in Beagle dogs that were exposed by inhalation to 106 RuO 4 . Twenty-six dogs were exposed nose-only to 106 RuO 4 and sacrificed at times from 2 hr to 512 days after inhalation exposure. Ninety-nine percent of the initial body burden was retained with an effective half-time of 1.2 days, 0.7% with a half-time of 14 days and 0.3% with a half-time of 170 days. Initial deposition was primarily in the nasopharyngeal and tracheobronchial regions. Results for deposition and retention of 106 Ru inhaled as 106 RuO 4 in dogs were similar to what has been observed for humans. The data for dogs were used to develop a model to predict potential radiation exposure patterns for humans after inhalation exposure to 106 RuO 4 . The model indicates that for humans the nasopharyngeal region, lower large intestine, and tracheobronchial epithelium would receive approx. 36, 13 and 10 times, respectively, the dose to 500 days after inhalation exposure to 106 RuO 4 that the lung would receive. The nasopharyngeal region should be considered the critical region for inhalation exposures to 106 RuO 4 . (author)

  12. CAPD Software Development for Automatic Piping System Design: Checking Piping Pocket, Checking Valve Level and Flexibility

    International Nuclear Information System (INIS)

    Ari Satmoko; Edi Karyanta; Dedy Haryanto; Abdul Hafid; Sudarno; Kussigit Santosa; Pinitoyo, A.; Demon Handoyo

    2003-01-01

    One of several steps in industrial plant construction is preparing piping layout drawing. In this drawing, pipe and all other pieces such as instrumentation, equipment, structure should be modeled A software called CAPD was developed to replace and to behave as piping drafter or designer. CAPD was successfully developed by adding both subprogram CHKUPIPE and CHKMANV. The first subprogram can check and gives warning if there is piping pocket in the piping system. The second can identify valve position and then check whether valve can be handled by operator hand The main program CAPD was also successfully modified in order to be capable in limiting the maximum length of straight pipe. By limiting the length, piping flexibility can be increased. (author)

  13. Piping engineering and operation

    International Nuclear Information System (INIS)

    1993-01-01

    The conference 'Piping Engineering and Operation' was organized by the Institution of Mechanical Engineers in November/December 1993 to follow on from similar successful events of 1985 and 1989, which were attended by representatives from all sectors of the piping industry. Development of engineering and operation of piping systems in all aspects, including non-metallic materials, are highlighted. The range of issues covered represents a balance between current practices and implementation of future international standards. Twenty papers are printed. Two, which are concerned with pressurized pipes or steam lines in the nuclear industry, are indexed separately. (Author)

  14. Introduction to Heat Pipes

    Science.gov (United States)

    Ku, Jentung

    2015-01-01

    This is the presentation file for the short course Introduction to Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. NCTS 21070-15. Course Description: This course will present operating principles of the heat pipe with emphases on the underlying physical processes and requirements of pressure and energy balance. Performance characterizations and design considerations of the heat pipe will be highlighted. Guidelines for thermal engineers in the selection of heat pipes as part of the spacecraft thermal control system, testing methodology, and analytical modeling will also be discussed.

  15. 46 CFR 56.75-30 - Pipe joining details.

    Science.gov (United States)

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... cut or machined square and the edges shall be held closely together to insure a satisfactory joint. (b... satisfactory for the brazing alloy to be employed, method of heating, and material to be joined. The annular...

  16. A real-time integrator of storage-area contents for SA 40B or DIDAC 800 analyzers. Use in the digital single-channel mode

    International Nuclear Information System (INIS)

    Rigaudiere, Roger; Daburon, M.-L.

    1976-09-01

    An apparatus was developed in order to sum up, during counting, the channel contents from several storage areas of SA 40 B or DIDAC 800 multichannel analyzers. The pulse number stored in the energy bands interesting the operator are known and if necessary subsequent operation can be modified accordingly. Coupled with an autonomous amplitude encoder, this apparatus can be operated in the digital single-channel mode [fr

  17. Research program plan: piping. Volume 3

    International Nuclear Information System (INIS)

    Vagins, M.; Strosnider, J.

    1985-07-01

    Regulatory issues related to piping can be divided into the three areas of pipe cracking, postulated design basis pipe breaks, and design of piping for seismic and other dynamic loads. The first two of these issues are in the domain of the Materials Engineering Branch (MEBR), while the last of the three issues is the responsibility of the Mechanical/Structural Engineering Branch. This volume of the MEBR Research Plan defines the critical aspects of the pipe cracking and postulated design basis pipe break issues and identifies those research efforts and results necessary for their resolution. In general, the objectives of the MERB Piping Research Program are to provide experimentally validated analytic techniques and appropriate material properties characterization methods and data to support regulatory activities related to evaluating and ensuring piping integrity

  18. Ultrasonic testing with the phased array method at the pipe connection inner edges in pipings

    International Nuclear Information System (INIS)

    Brekow, G.; Wuestenberg, H.; Hesselmann, H.; Rathgeb, W.

    1991-01-01

    Ultrasonic testing with the phased array method at the pipe connection inner edges in pipings. The pipe connection inner corner tests in feedwater lines to the main coolant pipe were carried out by Preussen-Elektra in cooperation with Siemens KWU and the BAM with the ultrasonic phased array method. The testing plan was developed by means of a computed model. For a trial of the testing plan, numerous ultrasonic measurements with the phased array method were carried out using a pipe test piece with TH-type inner edges, which was a 1:1 model of the reactor component to be tested. The data measured at several test notches in the pipe connection inner edge area covered by a plating of 6 mm were analyzed. (orig./MM) [de

  19. A risk-based approach to sanitary sewer pipe asset management.

    Science.gov (United States)

    Baah, Kelly; Dubey, Brajesh; Harvey, Richard; McBean, Edward

    2015-02-01

    Wastewater collection systems are an important component of proper management of wastewater to prevent environmental and human health implications from mismanagement of anthropogenic waste. Due to aging and inadequate asset management practices, the wastewater collection assets of many cities around the globe are in a state of rapid decline and in need of urgent attention. Risk management is a tool which can help prioritize resources to better manage and rehabilitate wastewater collection systems. In this study, a risk matrix and a weighted sum multi-criteria decision-matrix are used to assess the consequence and risk of sewer pipe failure for a mid-sized city, using ArcGIS. The methodology shows that six percent of the uninspected sewer pipe assets of the case study have a high consequence of failure while four percent of the assets have a high risk of failure and hence provide priorities for inspection. A map incorporating risk of sewer pipe failure and consequence is developed to facilitate future planning, rehabilitation and maintenance programs. The consequence of failure assessment also includes a novel failure impact factor which captures the effect of structurally defective stormwater pipes on the failure assessment. The methodology recommended in this study can serve as a basis for future planning and decision making and has the potential to be universally applied by municipal sewer pipe asset managers globally to effectively manage the sanitary sewer pipe infrastructure within their jurisdiction. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Characterization of pipes, drain lines, and ducts using the pipe explorer system

    International Nuclear Information System (INIS)

    Cremer, C.D.; Kendrick, D.T.; Cramer, E.

    1997-01-01

    As DOE dismantles its nuclear processing facilities, site managers must employ the best means of disposing or remediating hundreds of miles of potentially contaminated piping and duct work. Their interiors are difficult to access, and in many cases even the exteriors are inaccessible. Without adequate characterization, it must be assumed that the piping is contaminated, and the disposal cost of buried drain lines can be on the order of $1,200/ft and is often unnecessary as residual contamination levels often are below free release criteria. This paper describes the program to develop a solution to the problem of characterizing radioactive contamination in pipes. The technical approach and results of using the Pipe Explorer trademark system are presented. The heart of the system is SEA's pressurized inverting membrane adapted to transport radiation detectors and other tools into pipes. It offers many benefits over other pipe inspection approaches. It has video and beta/gamma detection capabilities, and the need for alpha detection has been addressed through the development of the Alpha Explorer trademark. These systems have been used during various stages of decontamination and decommissioning of DOE sites, including the ANL CP-5 reactor D ampersand D. Future improvements and extensions of their capabilities are discussed

  1. 36 CFR 800.2 - Participants in the Section 106 process.

    Science.gov (United States)

    2010-07-01

    ... legal and financial responsibility for section 106 compliance in accordance with subpart B of this part... that historic properties are taking into consideration at all levels of planning and development. (ii... properties, including those of traditional religious and cultural importance, articulate its views on the...

  2. Pipe rupture and steam/water hammer design loads for dynamic analysis of piping systems

    International Nuclear Information System (INIS)

    Strong, B.R. Jr.; Baschiere, R.J.

    1978-01-01

    The design of restraints and protection devices for nuclear Class I and Class II piping systems must consider severe pipe rupture and steam/water hammer loadings. Limited stress margins require that an accurate prediction of these loads be obtained with a minimum of conservatism in the loads. Methods are available currently for such fluid transient load development, but each method is severely restricted as to the complexity and/or the range of fluid state excursions which can be simulated. This paper presents a general technique for generation of pipe rupture and steam/water hammer design loads for dynamic analysis of nuclear piping systems which does not have the limitations of existing methods. Blowdown thrust loadings and unbalanced piping acceleration loads for restraint design of all nuclear piping systems may be found using this method. The technique allows the effects of two-phase distributed friction, liquid flashing and condensation, and the surrounding thermal and mechanical equipment to be modeled. A new form of the fluid momentum equation is presented which incorporates computer generated fluid acceleration histories by inclusion of a geometry integral termed the 'force equivalent area' (FEA). The FEA values permit the coupling of versatile thermal-hydraulic programs to piping dynamics programs. Typical applications of the method to pipe rupture problems are presented and the resultant load histories compared with existing techniques. (Auth.)

  3. Varyasyong Leksikal sa mga Dayalektong Mandaya

    Directory of Open Access Journals (Sweden)

    Dr. Raymund M. Pasion

    2014-12-01

    Full Text Available Layuning panlahat sa pag-aaral na ito na tuklasin ang varyasyong leksikalsa Wikang Mandaya na matatagpuan sa Probinsyang Davao Oriental. Bilang lunsaran sa paglilikom ng mga datos, ginamit ang mga terminong kultural na pangkabuhayan tulad ng pagsasaka, pangangaso, pangingisda at paghahayupan nanababatay sa Indigenous Knowledge System and Practices (IKSP.Sinikap sagutin sa pagaaral ang suliraning ano-anong varyasyong liksikal ang makikita sa mga terminong kultural na pangkabuhayan ng Mandaya na makikita sa munisipalidad ng Caraga, Manay, Bagangaat Cateel? Disenyong kwalitatibo ginamit.Metodong indehinusat deskriptibo naman ang ginamit mula sa paglilikom hanggang sa pag-aanalisa ng mga datos. Samantalang, ang mga impormante ay pinilisa pamamagitan ng kombinasyong purposive at snow-ball sampling. Natuklasan, na ang wikang Mandaya ay nakitaan ng varyasyong lekisikal ayon sa magkakaiba ang anyo, may pagkakatulad ang anyo, at magkakatulad ang anyo subalit magkakaiba ang bigkas. Gayunpaman, pinaniniwalaang dahil sa paktor na heograpikal, sikolohikal at sosyolohikal na nagaganap sa kanilang kultura ay hindi rin maipagkailang nagyari ang varyasyong leksikal na aspekto nito.

  4. Effects of Induction Heat Bending and Heat Treatment on the Boric Acid Corrosion of Low Alloy Steel Pipe for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki-Tae; Kim, Young-Sik [Andong National University, Gyeongbuk (Korea, Republic of); Chang, Hyun-Young; Park, Heung-Bae [KEPCO EandC, Gyeongbuk (Korea, Republic of); Sung, Gi-Ho; Shin, Min-Chul [Sungil SIM Co. Ltd, Busan (Korea, Republic of)

    2016-11-15

    In many plants, including nuclear power plants, pipelines are composed of numerous fittings such as elbows. When plants use these fittings, welding points need to be increased, and the number of inspections also then increases. As an alternative to welding, the pipe bending process forms bent pipe by applying strain at low or high temperatures. This work investigates how heat treatment affects on the boric acid corrosion of ASME SA335 Gr. P22 caused by the induction heat bending process. Microstructure analysis and immersion corrosion tests were performed. It was shown that every area of the induction heat bent pipe exhibited a high corrosion rate in the boric acid corrosion test. This behavior was due to the enrichment of phosphorous in the ferrite phase, which occurred during the induction heat bending process. This caused the ferrite phase to act as a corrosion initiation site. However, when re-heat treatment was applied after the bending process, it enhanced corrosion resistance. It was proved that this resistance was closely related to the degree of the phosphorus segregation in the ferrite phase.

  5. Fabrication of a multi-walled metal pipe

    International Nuclear Information System (INIS)

    Shimamune, Koji; Toda, Saburo; Ishida, Ryuichi; Hatanaka, Tatsuo.

    1969-01-01

    In concentrically arranged metal pipes for simulated fuel elements in the form of a multi-walled pipe, their one end lengthens gradually in the axial direction from inner and outer pipes toward a central pipe for easy adjustment of deformation which occurs when the pipes are drawn. A plastic electrical insulator is disposed between adjacent pipes. Each end of the pipes is equipped with an annular flexible stopper which is allowed to travel in the axial direction so as to prevent the insulator from falling during drawing work. At the other end, all pipes are constricted and joined to each other to thereby form the desired multi-walled pipe. (Mikami, T.)

  6. Rebalance between 7S and 11S globulins in soybean seeds of differing protein content and 11SA4.

    Science.gov (United States)

    Yang, A; Yu, X; Zheng, A; James, A T

    2016-11-01

    Protein content and globulin subunit composition of soybean seeds affect the quality of soy foods. In this proteomic study, the protein profile of soybean seeds with high (∼45.5%) or low (∼38.6%) protein content and with or without the glycinin (11S) subunit 11SA4 was examined. 44 unique proteins and their homologues were identified and showed that both protein content and 11SA4 influenced the abundance of a number of proteins. The absence of 11SA4 exerted a greater impact than the protein content, and led to a decreased abundance of glycinin G2/A2B1 and G5/A5A4B3 subunits, which resulted in lower total 11S with a concomitant higher total β-conglycinin (7S). Low protein content was associated with higher glycinin G3/A1aB1b and lower glycinin G4/A5A4B3. Using the proteomic approach, it was demonstrated that 11SA4 deficiency induced compensatory accumulation of 7S globulins and led to a similar total abundance for 7S+11S irrespective of protein content or 11SA4. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Reliability analysis of stiff versus flexible piping

    International Nuclear Information System (INIS)

    Lu, S.C.

    1985-01-01

    The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. The authors then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. They concluded that these changes substantially reduce calculated piping responses and allow piping redesigns with significant reduction in number of supports and snubbers without violating ASME code requirements. Furthermore, the more flexible piping redesigns are capable of exhibiting reliability levels equal to or higher than the original stiffer design. An investigation of the malfunction of pipe whip restraints confirmed that the malfunction introduced higher thermal stresses and tended to reduce the overall piping reliability. Finally, support and component reliabilities were evaluated based on available fragility data. Results indicated that the support reliability usually exhibits a moderate decrease as the piping flexibility increases. Most on-line pumps and valves showed an insignificant reduction in reliability for a more flexible piping design

  8. A vitamini ve anne çocuk sağlığı Derleme

    OpenAIRE

    Günlemez, Ayla; Atasay, Begüm; Arsan, Saadet

    2014-01-01

    A vitamini normal görmede hücre farklılaşmasında çoğalmasında ve epitelial bütünlüğün sağlanmasında kritik rol oynar Gelişmekte olan ülkelerde A vitamini eksikliği önemli ve önlenebilir halk sağlığı sorunlarından biridir Bu makalede dünyada ve Türkiye’de A vitamini eksikliği ve anne çocuk sağlığı üzerine etkileri tartışılmaktadır Anahtar Kelimeler: A vitamini anne sağlığı çocuk sağlığıSummaryVitamin A has a critical role in normal vision cell differantiation proliferation and maintanence of e...

  9. Heat pipes in modern heat exchangers

    International Nuclear Information System (INIS)

    Vasiliev, Leonard L.

    2005-01-01

    Heat pipes are very flexible systems with regard to effective thermal control. They can easily be implemented as heat exchangers inside sorption and vapour-compression heat pumps, refrigerators and other types of heat transfer devices. Their heat transfer coefficient in the evaporator and condenser zones is 10 3 -10 5 W/m 2 K, heat pipe thermal resistance is 0.01-0.03 K/W, therefore leading to smaller area and mass of heat exchangers. Miniature and micro heat pipes are welcomed for electronic components cooling and space two-phase thermal control systems. Loop heat pipes, pulsating heat pipes and sorption heat pipes are the novelty for modern heat exchangers. Heat pipe air preheaters are used in thermal power plants to preheat the secondary-primary air required for combustion of fuel in the boiler using the energy available in exhaust gases. Heat pipe solar collectors are promising for domestic use. This paper reviews mainly heat pipe developments in the Former Soviet Union Countries. Some new results obtained in USA and Europe are also included

  10. Reactor primary coolant system pipe rupture study. Progress report No. 33, January--June 1975

    International Nuclear Information System (INIS)

    1975-10-01

    The pipe rupture study is designed to extend the understanding of failure-causing mechanisms and to provide improved capability for evaluating reactor piping systems to minimize the probability of failures. Following a detailed review to determine the effort most needed to improve nuclear system piping (Phase 1), analytical and experimental efforts (Phase 2) were started in 1965. This progress report summarizes the recent accomplishments of a broad program in (a) basic fatigue crack growth rate studies focused on LWR primary piping materials in a simulated BWR primary coolant environment, (b) at-reactor tests of the effect of primary coolant environment on the fatigue behavior of piping steels, (c) studies directed at quantifying weld sensitization in Type 304 stainless steel, (d) support studies to characterize the electrochemical potential behavior of a typical BWR primary water environment and (e) special tests related to simulation of fracture surfaces characteristic of IGSCC field failures

  11. Computational fluid dynamics analysis for flow accelerated corrosion in CANDU6 feeder pipes

    International Nuclear Information System (INIS)

    Catana, A.; Pauna, E.; Ioan, M.

    2013-01-01

    CANDU6 plant management over a long time period includes various ageing and degradation mechanisms like FAC manifested mainly at first and second elbow of CANDU6 outlet feeders. FAC take place at all CANDU6 built before 2000 year with feeders made from SA106 grade B low alloy carbon-steel (with chromium at 0.02%). CFD method is used in this paper to investigate the feeder's wall thinning process taking place mainly due local flow conditions in complex 3D geometrical configurations. The 380 outlet feeders grouped in 2.5'' (320) and 2.0'' feeders (60). The objective of this paper is to help, as much as possible, to focus investigation on most probable maximum thinning rate locations through 3D distribution of some TH parameters. Application of CFD methods in CANDU6 nuclear reactors implies the knowledge of real plant operating data like: long term time averaged channel power and mass flow as well as temperature, pressure, pHa etc allowing the optimization and cost reduction of wall thinning monitoring process at CANDU6 nuclear power plants. (authors)

  12. Leak before break piping evaluation diagram

    International Nuclear Information System (INIS)

    Fabi, R.J.; Peck, D.A.

    1994-01-01

    Traditionally Leak Before Break (LBB) has been applied to the evaluation of piping in existing nuclear plants. This paper presents a simple method for evaluating piping systems for LBB during the design process. This method produces a piping evaluation diagram (PED) which defines the LBB requirements to the piping designer for use during the design process. Several sets of LBB analyses are performed for each different pipe size and material considered in the LBB application. The results of this method are independent of the actual pipe routing. Two complete LBB evaluations are performed to determine the maximum allowable stability load, one evaluation for a low normal operating load, and the other evaluation for a high normal operating load. These normal operating loads span the typical loads for the particular system being evaluated. In developing the allowable loads, the appropriate LBB margins are included in the PED preparation. The resulting LBB solutions are plotted as a set of allowable curves for the maximum design basis load, such is the seismic load versus the normal operating load. Since the required margins are already accounted for in the LBB PED, the piping designer can use the diagram directly with the results of the piping analysis and determine immediately if the current piping arrangement passes LBB. Since the LBB PED is independent of pipe routing, changes to the piping system can be evaluated using the existing PED. For a particular application, all that remains is to confirm that the actual materials and pipe sizes assumed in creating the particular design are built into the plant

  13. 46 CFR 32.50-20 - Cargo piping for tank vessels constructed between November 10, 1936, and July 1, 1951-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Pumps, Piping, and Hose... may be omitted where the pipe is extra heavy, all joints are welded, and bends are installed to provide for expansion and contraction. (b) Cargo piping shall not pass through spaces containing machinery...

  14. Stress index development for piping with trunnion attachment under pressure and moment loading

    International Nuclear Information System (INIS)

    Lee, D. H.; Kim, J. M.; Park, S. H.

    1997-01-01

    A finite element analysis of a trunnion pipe anchor is presented. The structure is analyzed for the case of internal pressure and moment loadings. The stress results are categorized into the average (membrane) stress, the linearly varying (bending) stress and the peak stress through the thickness. The resulting stresses are interpreted per section III of the ASME boiler and pressure vessel code from which the Primary (B 1 ), Secondary (C 1 ) and Peak (K 1 ) stress indices for pressure, the Primary (B 2 ), Secondary (C 2 ) and Peak (K 2 ) stress indices for moment are developed. Based on the comparison between stress value by stress indices derived in this paper and stress value represented by the ASME Code Case N-391-1, the empirical equations for stress indices are effectively used in the piping stress analysis. Therefore, the use of empirical equations can simplify the procedure of evaluating the local stress in the piping design stage. (author)

  15. 7 CFR 1150.106 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1150.106 Section 1150.106 Agriculture... Order Definitions § 1150.106 United States. United States means the 48 contiguous States in the continental United States. ...

  16. 48 CFR 45.106 - Transferring accountability.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Transferring accountability. 45.106 Section 45.106 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT GOVERNMENT PROPERTY General 45.106 Transferring accountability. Government property...

  17. Effect of pipe rupture loads inside containment in the break exclusionary piping outside containment

    International Nuclear Information System (INIS)

    Weiss, G.

    1987-01-01

    The plant design for protection against piping failures outside containment should make sure that fluid system piping in containment penetration areas are designed to meet the break exclusionary provisions contained in the BTP MEB 3-1. According to these provisions, following a piping failure (main steam line) inside containment, the part of the flued head connected to the piping outside containment, should not exceed the ASME Code stress limits for the appropriate load combinations. A finite element analysis has been performed to evaluate the stress level in this area. (orig./HP)

  18. Heat pipe development

    Science.gov (United States)

    Bienart, W. B.

    1973-01-01

    The objective of this program was to investigate analytically and experimentally the performance of heat pipes with composite wicks--specifically, those having pedestal arteries and screwthread circumferential grooves. An analytical model was developed to describe the effects of screwthreads and screen secondary wicks on the transport capability of the artery. The model describes the hydrodynamics of the circumferential flow in triangular grooves with azimuthally varying capillary menisci and liquid cross-sections. Normalized results were obtained which give the influence of evaporator heat flux on the axial heat transport capability of the arterial wick. In order to evaluate the priming behavior of composite wicks under actual load conditions, an 'inverted' glass heat pipe was designed and constructed. The results obtained from the analysis and from the tests with the glass heat pipe were applied to the OAO-C Level 5 heat pipe, and an improved correlation between predicted and measured evaporator and transport performance were obtained.

  19. Pipe rupture test results; 6 in. pipe whip test under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Kurihara, Ryoichi; Yano, Toshikazu; Ueda, Shuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kato, Rokuro; Miyazono, Shohachiro

    1983-02-01

    A series of pipe rupture tests has been performed in JAERI to demonstrate the safety of the primary coolant circuits in the event of pipe rupture, in nuclear power plants. The present report summarizes the results of 6 in. pipe whip tests (RUN 5605, 5606), under BWR LOCA conditions (285 0 C, 6.8 MPa), which were performed in August, 1981. The test pipe is made of Type 304 stainless steel and its outer diameter is 6 in. and its thickness is 11.1 mm. The restraints are made of Type 304 stainless steel and its diameter is 16.0 mm. Two restraints were set on the restraint support with clearance of 100 mm. Overhang length was varied as the parameter in these tests and was 300 mm or 700 mm. The following results are obtained. (1) The deformations of a pipe and restraints are limited effectively by shorter overhang length of 300. However, they become larger when the overhang length is 700 mm, and the pipe deforms especially at the setting point of restraints. (2) Velocity at the free end of pipe becomes about 30 m/sec just after the break. However, velocity at the setting point of restraint becomes about only 4 m/sec just after the break. (3) It seems from the comparison between the 4 in. tests and 6 in. tests that the maximum restraint force of 6 in. tests is about two times as large as that of 4 in. tests. (author)

  20. Exercise Training Mitigates Water Pipe Smoke Exposure-Induced Pulmonary Impairment via Inhibiting NF-κB and Activating Nrf2 Signalling Pathways

    Directory of Open Access Journals (Sweden)

    Abderrahim Nemmar

    2018-01-01

    Full Text Available Water pipe smoking is a tobacco smoking method commonly used in Eastern countries and is gaining popularity in Europe and North America, in particular among adolescents and young adults. Several clinical and experimental studies have reported that exposure to water pipe smoke (WPS induces lung inflammation and impairment of pulmonary function. However, the mechanisms of such effects are not understood, as are data on the possible palliative effect of exercise training. The present study evaluated the effects of regular aerobic exercise training (treadmill: 5 days/week, 40 min/day on subchronic exposure to WPS (30 minutes/day, 5 days/week for 2 months. C57BL/6 mice were exposed to air or WPS with or without exercise training. Airway resistance measured using forced oscillation technique was significantly and dose-dependently increased in the WPS-exposed group when compared with the air-exposed one. Exercise training significantly prevented the effect of WPS on airway resistance. Histologically, the lungs of WPS-exposed mice had focal moderate interstitial inflammatory cell infiltration consisting of neutrophil polymorphs, plasma cells, and lymphocytes. There was a mild increase in intra-alveolar macrophages and a focal damage to alveolar septae in some foci. Exercise training significantly alleviated these effects and also decreased the WPS-induced increase of tumor necrosis factor α and interleukin 6 concentrations and attenuated the increase of 8-isoprostane in lung homogenates. Likewise, the lung DNA damage induced by WPS was significantly inhibited by exercise training. Moreover, exercise training inhibited nuclear factor kappa-B (NF-κB expression induced by WPS and increased that of nuclear factor erythroid 2-related factor 2 (Nrf2. Our findings suggest that exercise training significantly mitigated WPS-induced increase in airway resistance, inflammation, oxidative stress, and DNA damage via mechanisms that include inhibiting NF-κB and

  1. 48 CFR 570.106 - Publicizing/Advertising.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Publicizing/Advertising. 570.106 Section 570.106 Federal Acquisition Regulations System GENERAL SERVICES ADMINISTRATION SPECIAL CONTRACTING PROGRAMS ACQUIRING LEASEHOLD INTERESTS IN REAL PROPERTY General 570.106 Publicizing/Advertising...

  2. Differential Expression of MiR-106b-5p and MiR-200c-3p in Newly Diagnosed Versus Chronic Primary Immune Thrombocytopenia Patients Based on Systematic Analysis

    Directory of Open Access Journals (Sweden)

    Cheng Qian

    2018-01-01

    Full Text Available Background/Aims: MicroRNAs (miRNAs have been described to have important roles in primary immune thrombocytopenia (ITP. To gain additional understanding, we have now further evaluated the involvement of miRNAs in ITP. Methods: Microarray experiments were performed to examine the expression profiles of miRNAs and mRNAs in samples from subjects with newly diagnosed ITP (G1, chronic ITP (G2, and normal controls. The systematic Pipeline of Outlier MicroRNA Analysis framework was applied to identify key miRNAs expressed in the G1 and G2 samples. Quantitative PCR and receiver operator characteristic curves were used to confirm the performance of key miRNAs. Results: Compared with normal controls, 14 miRNAs (12 over-expressed and 2 under-expressed and 7 over-expressed miRNAs were identified as key in G1 and G2 samples, respectively. miR-106b-5p, miR-200c-3p, and miR-92a-3p exhibited significantly different expression profiles among the groups. In particular, miR-106b-5p and miR-200c-3p were expressed at higher levels in patients with ITP compared to the normal controls. Furthermore, these two miRNAs expressions were even higher in patients with chronic ITP. Conclusion: MiR-106b-5p and miR-200c-3p may represent valuable biomarkers of ITP, although further studies are needed to confirm and assess the value of these potential biomarkers at various stages of ITP.

  3. Replaceable liquid nitrogen piping

    International Nuclear Information System (INIS)

    Yasujima, Yasuo; Sato, Kiyoshi; Sato, Masataka; Hongo, Toshio

    1982-01-01

    This liquid nitrogen piping with total length of about 50 m was made and installed to supply the liquid nitrogen for heat insulating shield to three superconducting magnets for deflection and large super-conducting magnet for detection in the π-meson beam line used for high energy physics experiment in the National Laboratory for High Energy Physics. The points considered in the design and manufacture stages are reported. In order to minimize the consumption of liquid nitrogen during transport, vacuum heat insulation method was adopted. The construction period and cost were reduced by the standardization of the components, the improvement of welding works and the elimination of ineffective works. For simplifying the maintenance, spare parts are always prepared. The construction and the procedure of assembling of the liquid nitrogen piping are described. The piping is of double-walled construction, and its low temperature part was made of SUS 316L. The super-insulation by aluminum vacuum evaporation and active carbon were attached on the external surface of the internal pipe. The final leak test and the heating degassing were performed. The tests on evacuation, transport capacity and heat entry are reported. By making the internal pipe into smaller size, the piping may be more efficient. (Kako, I.)

  4. Transients in pipes

    International Nuclear Information System (INIS)

    Marchesin, D.; Paes-Leme, P.J.S.; Sampaio, R.

    1981-01-01

    The motion of a fluid in a pipe is commonly modeled utilizing the one space dimension conservation laws of mass and momentum. The development of shocks and spikes utilizing the uniform sampling method is studied. The effects of temperature variations and friction are compared for gas pipes. (Author) [pt

  5. Current results for the NRC's short cracks in piping and piping welds research program

    International Nuclear Information System (INIS)

    Wilkowski, G.; Krishnaswamy, P. Brust, F.; Francini, R.; Ghadiali, N.; Kilinski, T.; Marschall, C.; Rahman, S.; Rosenfield, A.; Scott, P.

    1994-01-01

    The overall objective of the Short Cracks in Piping and Piping Welds Program is to verify and improve engineering analyses to predict the fracture behavior of circumferentially cracked pipe under quasi-static loading with particular attention to crack lengths typically used in LBB or flaw evaluation criteria. The program consists of 8 technical tasks as listed below. Task 1 Short through-wall-cracked (TWC) pipe evaluations. Task 2 Short surface-cracked pipe evaluations. Task 3 Bi-metallic weld crack evaluations. Task 4 Dynamic strain aging and crack instabilities. Task 5 Fracture evaluations of anisotropic pipe. Task 6 Crack-opening-area evaluations. Task 7 NRCPIPE Code improvements. Task 8 Additional efforts. Since the last WRSM meeting several additional tasks have been initiated in this program. These are discussed in Task 8. Based on results to date, the first seven tasks have also been modified as deemed necessary. The most significant accomplishments in each of these tasks since the last WRSIM meeting are discussed below. The details of all the results presented here are published in the semiannual reports from this program

  6. A intersetorialidade saúde e educação para a construção de escolas promotoras de saúde: percepções dos profissionais ligados ao curso a distância gestão de projetos de investimento em saúde

    Directory of Open Access Journals (Sweden)

    Elomar Castilho BARILLI

    2013-09-01

    Full Text Available O artigo apresenta a pesquisa qualitativa realizada no curso a distância Gestão de Projetos de Investimento em Saúde, com o objetivo de verificar as possibilidades de qualificação da educação básica pela inter-relação entre os princípios do Sistema Único de Saúde e as diretrizes dos Parâmetros Curriculares Nacionais. Sua execução se deu em duas fases por meio da reflexão dos 303 alunos (participantes, acerca da intersetorialidade na prática cotidiana, a partir de duas questões deflagradoras, registradas em dois instrumentos - Planilha de Repertório e Relatório de Pesquisa. Os modelos epistemológicos de Análise de Conteúdo e Análise do Discurso embasaram a análise dos dados, a partir dos quais foram estruturadas categorias de significação, sendo as de âmbito político e técnico-profissional as mais frequentes. A pesquisa contribuiu para a conscientização crítica dos educandos quanto à resolutividade das ações de saúde na educação básica, entendendo a intersetorialidade – Educação/Saúde – como um dos eixos estruturantes das políticas públicas nacionais.

  7. PPOOLEX experiments with two parallel blowdown pipes

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2011-01-15

    This report summarizes the results of the experiments with two transparent blowdown pipes carried out with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through either one or two vertical transparent blowdown pipes to the condensation pool. Five experiments with one pipe and six with two parallel pipes were carried out. The main purpose of the experiments was to study loads caused by chugging (rapid condensation) while steam is discharged into the condensation pool filled with sub-cooled water. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. In the experiments the initial temperature of the condensation pool water varied from 12 deg. C to 55 deg. C, the steam flow rate from 40 g/s to 1 300 g/s and the temperature of incoming steam from 120 deg. C to 185 deg. C. In the experiments with only one transparent blowdown pipe chugging phenomenon didn't occur as intensified as in the preceding experiments carried out with a DN200 stainless steel pipe. With the steel blowdown pipe even 10 times higher pressure pulses were registered inside the pipe. Meanwhile, loads registered in the pool didn't indicate significant differences between the steel and polycarbonate pipe experiments. In the experiments with two transparent blowdown pipes, the steamwater interface moved almost synchronously up and down inside both pipes. Chugging was stronger than in the one pipe experiments and even two times higher loads were measured inside the pipes. The loads at the blowdown pipe outlet were approximately the same as in the one pipe cases. Other registered loads around the pool were about 50-100 % higher than with one pipe. The experiments with two parallel blowdown pipes gave contradictory results compared to the earlier studies dealing with chugging loads in case of multiple pipes. Contributing

  8. Automated ultrasonic pipe weld inspection. Part 1

    International Nuclear Information System (INIS)

    Karl Deutsch, W.A.; Schulte, P.; Joswig, M.; Kattwinkel, R.

    2006-01-01

    This article contains a brief overview on automated ultrasonic welded inspection for various pipe types. Some inspection steps might by carried out with portable test equipment (e.g. pipe and test), but the weld inspection in all internationally relevant specification must be automated. The pipe geometry, the production process, and the pipe usage determine the number of required probes. Recent updates for some test specifications enforce a large number of ultrasonic probes, e.g. the Shell standard. Since seamless pipes are sometimes replaced by ERW pipes and LSAW pipes (in both cases to save production cost), the inspection methods change gradually between the various pipe types. Each testing system is unique and shows its specialties which have to be discussed by supplier, testing system user and final customer of the pipe. (author)

  9. Excesso de peso em usuários de unidades básicas de saúde

    Directory of Open Access Journals (Sweden)

    Eduardo Alves da Silva

    2016-05-01

    Full Text Available Introdução: O conhecimento sobre estado nutricional da população norteia o estabelecimento de políticas públicas em saúde. Objetivo: Avaliar o estado nutricional e as características sociodemográficas de usuários das unidades básicas de saúde (UBSs de Carapicuíba, São Paulo. Métodos: Estudo transversal com 384 adultos distribuídos em 13 UBSs do município. Foram coletados dados quanto a idade, gênero, escolaridade, informações para a classificação econômica, estado civil, circunferência da cintura (CC, peso e estatura para cálculo do índice de massa corporal (IMC. Resultados: A idade média foi de 40,18+10,51 anos, houve maior prevalência de indivíduos casados (60,36%, de classe social C (64,71% e com ensino médio completo (48,08%. O IMC médio foi 28,42 kg/m², e a CC, de 94,09 cm. Observa-se que 31,97% estão em sobrepeso e 37,85% são obesos. Quanto à CC, 16,11% apresentam risco aumentado e 64,2% risco aumentado substancialmente para doença metabólica. As mulheres casadas possuem IMC (p=0,0054 e CC (p=0,0279 maiores que as mulheres solteiras. Mulheres têm CC maior que os homens (p0,05. Conclusão: O excesso de peso foi encontrado com frequência em todos os grupos de renda. As mulheres casadas apresentaram IMC e CC maiores que as solteiras. Os homens de classe econômica alta têm CC maior que os de classe baixa.

  10. Nitrogen heat pipe for cryocooler thermal shunt

    International Nuclear Information System (INIS)

    Prenger F.C.; Hill, D.D.; Daney, D.E.

    1996-01-01

    A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in this temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined

  11. 28 CFR 301.106 - Repetitious accidents.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Repetitious accidents. 301.106 Section 301.106 Judicial Administration FEDERAL PRISON INDUSTRIES, INC., DEPARTMENT OF JUSTICE INMATE ACCIDENT COMPENSATION General § 301.106 Repetitious accidents. If an inmate worker is involved in successive accidents...

  12. 48 CFR 745.106 - Contract clauses.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract clauses. 745.106 Section 745.106 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT CONTRACT MANAGEMENT GOVERNMENT PROPERTY General 745.106 Contract clauses. (a) The contracting officer shall insert the...

  13. 76 FR 62762 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-10-11

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  14. Pipe grabber

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Mubashirov, S.G.; Prokopov, O.I.

    1981-05-15

    A pipe grabber is suggested which contains a housing, clamping elements and centering mechanism with drive installed on the lower end of the housing. In order to improve the reliable operation of the pipe grabber, the centering mechanism is made in the form of a reinforced ringed flexible shaft, while the drive is made in the form of elastic rotating discs. In this case the direction of rotation of the discs and the flexible shaft is the opposite.

  15. Advanced industrial ceramic heat pipe recuperators

    Energy Technology Data Exchange (ETDEWEB)

    Strumpf, H.J.; Stillwagon, T.L.; Kotchick, D.M.; Coombs, M.G.

    1988-01-01

    This paper summarizes the results of an investigation involving the use of ceramic heat pipe recuperators for high-temperature heat recovery from industrial furnaces. The function of the recuperator is to preheat combustion air with furnace exhaust gas. The heat pipe recuperator comprises a bundle of individual ceramic heat pipes acting in concert, with a partition separating the air and exhaust gas flow streams. Because each heat pipe is essentially an independent heat exchanger, the failure of a single tube does not compromise recuperator integrity, has only a minimal effect on overall heat exchanger performance and enables easier replacement of individual heat pipes. In addition, the heat pipe acts as an essentially isothermal heat transfer device, leading to a high thermodynamic efficiency. Cost estimates developed for heat pipe recuperator systems indicate favorable payback periods. Laboratory studies have demonstrated the feasibility of fabricating the required ceramic tubes, coating the inside of the tubes with CVD tungsten, and sealing the heat pipe with an electron-beam-welded or vacuum-brazed end cap.

  16. Dynamic circumferential ductile crack motion in finite length pipes with various end loadings

    International Nuclear Information System (INIS)

    Emery, A.F.; Kobayashi, A.S.; Love, W.J.; Perl, M.; Kistler, B.

    1981-01-01

    The computed time history, crack opening shape and tip velocity are presented for the ductile crack extension of circumferential cracks in finite length pipes. The pipes are loaded by: a) constant axial tension, b) constant axial displacement, c) constant end moment, and d) constant end rotation to study the effects of these significantly different types of loads. The crack extension is based upon a critical crack opening angle criterion. The results indicate that the extent of the crack movement and the extension velocity is primarily dependent upon the inertia of the moving pipe segments. With sufficient linear momentum, complete severance is obtained, while if the movement is more rotation than translation the cracks either do not extend or do so only slightly. Thus in tougher material, once it begins to extend, the crack may easily encircle the pipe while in more brittle materials it may not, since the moving segments of the pipe have not had time to develop sufficient momentum to force the continued extension of the crack into regions which are initially in compression. (orig.)

  17. 41 CFR 105-1.106 - Applicability.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Applicability. 105-1.106 Section 105-1.106 Public Contracts and Property Management Federal Property Management Regulations System (Continued) GENERAL SERVICES ADMINISTRATION 1-INTRODUCTION 1.1-Regulations System § 105-1.106 Applicability...

  18. Residual stress improvement for pipe weld by means of induction heating pre-flawed pipe

    International Nuclear Information System (INIS)

    Umemoto, T.; Yoshida, K.; Okamoto, A.

    1980-01-01

    The intergranular stress corrosion cracking (IGSCC) has been found in type 304 stainless steel piping of several BWR plants. It is already well known that IGSCC is most likely to occur when three essential factors, material sensitization, high tensile stress and corrosive environment, are present. If the welding residual stress is sufficiently high (200 to approximately 400 MPa) in the inside piping surface near the welded joint, then it may be one of the biggest contributors to IGSCC. If the residual stress is reduced or reversed by some way, the IGSCC will be effectively mitigated. In this paper a method to improve the residual stress named IHSI (Induction Heating Stress Improvement) is explained. IHSI aims to improve the condition of residual stress in the inside pipe surface using the thermal stress induced by the temperature difference in pipe wall, that is produced when the pipe is heated from the outside surface by an induction heating coil and cooled on the inside surface by water simultaneously. This method becomes more attractive when it can be successfully applied to in-service piping which might have some pre-flaw. In order to verify the validity of IHSI for such piping, some experiments and calculations using finite element method were conducted. These results are mainly discussed in this paper from the view-points of residual stress, flaw behaviour during IHSI and material deterioration. (author)

  19. Programa Saúde da Família no Brasil: uma agenda incompleta?

    Directory of Open Access Journals (Sweden)

    Maria Fátima de Sousa

    Full Text Available Este artigo trata de uma análise longitudinal da experiência brasileira com o Programa Saúde da Família (PSF, ao longo dos doze anos da sua implantação e implementação. Toma como ponto de partida o propósito fundamental desta estratégia, que é a reorganização da atenção básica de saúde, contextualizando à luz da experiência que é única e peculiar ao Sistema Único de Saúde (SUS. Evidencia os avanços e desafios do PSF, apontando nesse sentido as necessidades mais urgentes em termos de incorporação tecnológica, formação da força de trabalho, estabelecimento de novos mecanismos e pactos em torno do financiamento da atenção básica e encaminhamento de novas estratégias e tecnologias nos processos de monitoramento e avaliação. Finaliza apontando elementos para subsidiar um debate sobre as questões em pauta, o qual deve ser permanente e lúcido na perspectiva da construção do SUS e do direito à saúde.

  20. TMEM106B gene polymorphism is associated with age at onset in granulin mutation carriers and plasma granulin protein levels

    Science.gov (United States)

    Cruchaga, Carlos; Graff, Caroline; Chiang, Huei-Hsin; Wang, Jun; Hinrichs, Anthony L.; Spiegel, Noah; Bertelsen, Sarah; Mayo, Kevin; Norton, Joanne B.; Morris, John C.; Goate, Alison

    2011-01-01

    Objective A recent genome-wide association study for frontotemporal lobar degeneration with TAR DNA-binding protein inclusions (FTLD-TDP), identified rs1990622 (TMEM106B) as a risk factor for FTLD-TDP. In this study we tested whether rs1990622 is associated with age at onset (AAO) in granulin (GRN) mutation carriers and with plasma GRN levels in mutation carriers and healthy elderly individuals. Design Rs1990622 was genotyped in GRN mutation carriers and tested for association with AAO using the Kaplan-Meier and a Cox proportional hazards model. Subjects We analyzed 50 affected and unaffected GRN mutation carriers from four previously reported FTLD-TDP families (HDDD1, FD1, HDDD2 and the Karolinska family). GRN plasma levels were also measured in 73 healthy, elderly individuals. Results The risk allele of rs1990622 is associated with a mean decrease of the age at onset of thirteen years (p=9.9×10−7), with lower plasma granulin levels in both healthy older adults (p = 4×10−4) and GRN mutation carriers (p=0.0027). Analysis of the HAPMAP database identified a non-synonymous single nucleotide polymorphism, rs3173615 (T185S) in perfect linkage disequilibrium with rs1990622. Conclusions The association of rs1990622 with AAO explains, in part, the wide range in the age at onset of disease among GRN mutation carriers. We hypothesize that rs1990622 or another variant in linkage disequilibrium could act in a manner similar to APOE in Alzheimer’s disease, increasing risk for disease in the general population and modifying AAO in mutation carriers. Our results also suggest that genetic variation in TMEM106B may influence risk for FTLD-TDP by modulating secreted levels of GRN. PMID:21220649

  1. Piping engineering for nuclear power plant

    International Nuclear Information System (INIS)

    Curto, N.; Schmidt, H.; Muller, R.

    1988-01-01

    In order to develop piping engineering, an adequate dimensioning and correct selection of materials must be secured. A correct selection of materials together with calculations and stress analysis must be carried out with a view to minimizing or avoiding possible failures or damages in piping assembling, which could be caused by internal pressure, weight, temperature, oscillation, etc. The piping project for a nuclear power plant is divided into the following three phases. Phase I: Basic piping design. Phase II: Final piping design. Phase III: Detail engineering. (Author)

  2. A interface entre o trabalho do agente comunitário de saúde e do fisioterapeuta na atenção básica à saúde Interface between the work of the community health agent and physiotherapist in the basic health care

    Directory of Open Access Journals (Sweden)

    Liliany Fontes Loures

    2010-07-01

    Full Text Available O estudo tem o objetivo de identificar as ações do fisioterapeuta e do agente comunitário de saúde na perspectiva da integração de suas atuações na atenção básica à saúde. Realizou-se uma revisão sistemática com o propósito de conhecer quais são essas atuações e, posteriormente, relacioná-las. O interesse surgiu durante o "Estágio Supervisionado em Atenção Primária à Saúde" e da observação de suas atuações. A partir da revisão de legislações e de trabalhos científicos atualizados acerca do assunto, verificou-se que tanto o agente comunitário de saúde quanto o fisioterapeuta são profissionais importantes na composição de uma equipe de saúde, pois contribuem à qualificação das ações de saúde junto à comunidade e à efetividade de um sistema de saúde universal, integral e equitativo. Ao final, constatou-se que há uma interação entre esses profissionais e uma integração entre suas atividades.The study is intended to identify the actions of the physiotherapist and community health agent in the context of the integration of their performances in the basic health care. A systematic review was performed with the purpose of knowing what are these performances, and then list them. The interest came from the "Supervised Training in the Primary Health Care" and the observation of their acts. From a law review and updated scientific works related to this subject, we noted that both, community health agent and physiotherapist, are important professionals in the composition of a health team, once they contribute to the qualification of the health actions among the community and the effectiveness of an universal, integral and equitable health system. Lastly we found that there is an interaction between these professionals and integration among their activities.

  3. Geochemical soil sampling for deeply-buried mineralized breccia pipes, northwestern Arizona

    Science.gov (United States)

    Wenrich, K.J.; Aumente-Modreski, R. M.

    1994-01-01

    degree of anomalousness, named the "correlation value", was used to rank collapse features by their potential to overlie a deeply-buried mineralized breccia pipe. Soil geochemical results from the three mineralized breccia pipes (the only three of the 50 that had previously been drilled) show that: (1) Soils above the SBF pipe contain significant enrichment of Ag, Al, As, Ba, Ga, K, La, Mo, Nd, Ni, Pb, Sc, Th, U and Zn, and depletion in Ca, Mg and Sr, in contrast to soils outside the topographic and structural rim; (2) Soils over the inner treeless zone of the Canyon pipe show Mo and Pb enrichment anf As and Ga depletion, in contrast to soils from the surrounding forest; and (3) The soil survey of the Mohawk Canyon pipe was a failure because of the rocky terrane and lack of a B soil horizon, or because the pipe plunges. At least 11 of the 47 other collapse structures studied contain anomalous soil enrichments similar to the SBF uranium ore-bearing pipe, and thus have good potential as exploration targets for uranium. One of these 11, #1102, does contain surface mineralized rock. These surveys suggest that soil geochemical sampling is a useful tool for the recognition of many collapse structures with underlying ore-bearing breccia pipes. ?? 1994.

  4. Leachate storage transport tanker loadout piping

    International Nuclear Information System (INIS)

    Whitlock, R.W.

    1994-01-01

    This report shows the modifications to the W-025 Trench No. 31 leachate loadout discharge piping, and also the steps involved in installing the discharge piping, including dimensions and welding information. The installation of the discharge pipe should be done in accordance to current pipe installation standards. Trench No. 31 is a radioactive mixed waste land disposal facility

  5. Da segurança e medicina do trabalho à Saúde do Trabalhador: história e desafios da Revista Brasileira de Saúde Ocupacional

    Directory of Open Access Journals (Sweden)

    José Marçal Jackson Filho

    2015-07-01

    Full Text Available Resumo A Revista Brasileira de Saúde Ocupacional (RBSO é o periódico científico do campo da Saúde do Trabalhador publicado pela Fundacentro desde 1973. O percurso histórico, o desempenho atual, os desafios e as perspectivas futuras da RBSO são discutidos a partir de análise documental. A história da revista pode ser dividida em três períodos, começando durante o governo militar. No início, se constituiu em veículo de difusão de conhecimentos e da política de prevenção de acidentes, na qual a Fundacentro desempenhava papel central. No início dos anos 80 abre-se espaço para publicações de caráter técnico científico, assim como o campo da Saúde do Trabalhador surge em suas páginas. Em 2005-6, um processo de reestruturação é implementado, assegurando política e estruturas editoriais independentes. Desde 2006, 139 artigos originais e nove dossiês temáticos foram publicados; a Revista está indexada em 9 bases; Qualis/CAPES B1 na área Interdisciplinar e B2 em Saúde coletiva, com tendência ascendente no Fator de Impacto SciELO e índice h5 no Google Scholar. Todavia, a relativa baixa produção científica no campo e o alto índice de rejeição de manuscritos podem colocar em risco a sobrevivência do “lócus principal” para publicações científicas no campo da Saúde do Trabalhador.

  6. ALARA plan for the Old Hydrofracture Facility tanks contents removal project at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Amendment 1 for Appendix B: Install flex-pipe on tank riser spools

    International Nuclear Information System (INIS)

    1998-01-01

    This amendment to Appendix B contains the specific ALARA evaluations for installing flex-pipe on riser spools to accommodate ventilation duct connections to the north risers of each tank. The work will be a routine task that is part of the Equipment Installation and Mobilization phase of the project. The dose rates were estimated using the recent Radiological Surveillance Section radiological survey: SAAS-97-063S. Task B-6 has been added to the OHF Project ALARA review process to address a field decision to modify an approach to installing the tank ventilation system. The revised approach will incorporate 12-in. diameter, 36-in. long, stainless steel flex-pipe connected to each north riser spool to address the problem of pipe fitting multiple bends and turns expected with the 12-in. PVC duct. This improved approach will reduce the time necessary to install the duct system between the tanks and the ventilation skid. However, the task includes opening the 12-in. riser spool connections to replace the currently installed blind gaskets. Since a riser spool for each tank will be opened, there is a potential for significant personnel exposure and spread of contamination that will addressed through this ALARA review process

  7. 5 CFR 960.106 - OPM leadership.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false OPM leadership. 960.106 Section 960.106 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) FEDERAL EXECUTIVE BOARDS § 960.106 OPM leadership. (a) Role of the Director. The Director is responsible to the...

  8. Dynamic experiments on cracked pipes

    International Nuclear Information System (INIS)

    Petit, M.; Brunet, G.; Buland, P.

    1991-01-01

    In order to apply the leak before break concept to piping systems, the behavior of cracked pipes under dynamic, and especially seismic loading must be studied. In a first phase, an experimental program on cracked stainless steel pipes under quasi-static monotonic loading has been conducted. In this paper, the dynamic tests on the same pipe geometry are described. These tests have been performed on a shaking table with a mono frequency input signal. The main parameter of the tests is the frequency of excitation versus the frequency of the system

  9. Water hammer in elastic pipes

    International Nuclear Information System (INIS)

    Gale, J.; Tiselj, I.

    2002-01-01

    One dimensional two-fluid six-equation model of two-phase flow, that can be found in computer codes like RELAP5, TRAC, and CATHARE, was upgraded with additional terms, which enable modelling of the pressure waves in elastic pipes. It is known that pipe elasticity reduces the propagation velocity of the shock and other pressure waves in the piping systems. Equations that include the pipe elasticty terms are used in WAHA code, which is being developed within the WAHALoads project of 5't'h EU research program.(author)

  10. Heat pipe dynamic behavior

    Science.gov (United States)

    Issacci, F.; Roche, G. L.; Klein, D. B.; Catton, I.

    1988-01-01

    The vapor flow in a heat pipe was mathematically modeled and the equations governing the transient behavior of the core were solved numerically. The modeled vapor flow is transient, axisymmetric (or two-dimensional) compressible viscous flow in a closed chamber. The two methods of solution are described. The more promising method failed (a mixed Galerkin finite difference method) whereas a more common finite difference method was successful. Preliminary results are presented showing that multi-dimensional flows need to be treated. A model of the liquid phase of a high temperature heat pipe was developed. The model is intended to be coupled to a vapor phase model for the complete solution of the heat pipe problem. The mathematical equations are formulated consistent with physical processes while allowing a computationally efficient solution. The model simulates time dependent characteristics of concern to the liquid phase including input phase change, output heat fluxes, liquid temperatures, container temperatures, liquid velocities, and liquid pressure. Preliminary results were obtained for two heat pipe startup cases. The heat pipe studied used lithium as the working fluid and an annular wick configuration. Recommendations for implementation based on the results obtained are presented. Experimental studies were initiated using a rectangular heat pipe. Both twin beam laser holography and laser Doppler anemometry were investigated. Preliminary experiments were completed and results are reported.

  11. Selenide isotope generator for the Galileo Mission: copper/water axially-grooved heat pipe topical report

    International Nuclear Information System (INIS)

    Strazza, N.P.

    1979-01-01

    This report presents a summary of the major accomplishments for the development, fabrication, and testing of axially-grooved copper/water heat pipes for Selenide Isotopic Generator (SIG) applications. The early development consisted of chemical, physical, and analytical studies to define an axially-grooved tube geometry that could be successfully fabricated and provide the desired long term (up to seven years) performance is presented. Heat pipe fabrication procedures, measured performance and accelerated life testing of heat pipes S/Ns AL-5 and LT-57 conducted at B and K Engineering are discussed. S/N AL-5 was the first axially-grooved copper/water heat pipe that was fabricated with the new internal coating process for cupric oxide (CuO) and the cleaning and water preparation methods developed by Battelle Columbus Laboratories. Heat pipe S/N LT-57 was fabricated along with sixty other axially-grooved heat pipes allocated for life testing at Teledyne Energy Systems. As of June 25, 1979, heat pipes S/Ns AL-5 and LT-57 have been accelerated life tested for 13,310 and 6,292 respectively, at a nominal operating temperature of 225 0 C without any signs of thermal performance degradation

  12. Preliminary treatment of bovine mastitis caused by Staphylococcus aureus, with trx-SA1, recombinant endolysin of S. aureus bacteriophage IME-SA1.

    Science.gov (United States)

    Fan, Jindai; Zeng, Zhiliang; Mai, Kaijie; Yang, Yu; Feng, Jiaqi; Bai, Yang; Sun, Baoli; Xie, Qingmei; Tong, Yigang; Ma, Jingyun

    2016-08-15

    Methicillin-resistant Staphylococcus aureus (MRSA) has become a great threat to human and animal health and there is an urgent need to develop novel antibacterial agents to control this pathogen. The objective of this study was to obtain an active recombinant endolysin from the novel bacteriophage (IME-SA1), and conduct an efficacy trial of its effectiveness against bovine mastitis. We isolated a phage that was virulent and specific for S. aureus with an optimal multiplicity of infection of 0.01. Electron microscopy revealed that IME-SA1 was a member of the family Myoviridae, with an isometric head (98nm) and a long contractile tail (200nm). Experimental lysis experiments indicated the phage had an incubation period of 20min with a burst size of 80. When host bacteria were in early exponential growth stages, a multiplicity of infection of 0.01 resulted in a complete bacterial lysis after 9h. The endolysin gene (804bp) was cloned into the pET-32a bacterial expression vector and recombinant endolysin Trx-SA1 was successfully obtained with molecular size of about 47kDa. Preliminary results of therapeutic trials in cow udders showed that Trx-SA1 could effectively control mild clinical mastitis caused by S. aureus. The endolysin Trx-SA1 might be an alternative treatment strategy for infections caused by S. aureus, including MRSA. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. 30 CFR 210.106 - Where can I find more information on how to complete these production reports?

    Science.gov (United States)

    2010-07-01

    ... complete these production reports? 210.106 Section 210.106 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR MINERALS REVENUE MANAGEMENT FORMS AND REPORTS Production Reports-Oil and Gas § 210...Services/Handbooks/Handbks.htm or from MMS at P.O. Box 17110, Denver, Colorado 80217-0110. (b) Production...

  14. Failure rates in Barsebaeck-1 reactor coolant pressure boundary piping. An application of a piping failure database

    International Nuclear Information System (INIS)

    Lydell, B.

    1999-05-01

    This report documents an application of a piping failure database to estimate the frequency of leak and rupture in reactor coolant pressure boundary piping. The study used Barsebaeck-1 as reference plant. The study tried two different approaches to piping failure rate estimation: 1) PSA-style, simple estimation using Bayesian statistics, and 2) fitting of statistical distribution to failure data. A large, validated database on piping failures (like the SKI-PIPE database) supports both approaches. In addition to documenting leak and rupture frequencies, the SKI report describes the use of piping failure data to estimate frequency of medium and large loss of coolant accidents (LOCAs). This application study was co sponsored by Barsebaeck Kraft AB and SKI Research

  15. 29 CFR 1614.106 - Individual complaints.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Individual complaints. 1614.106 Section 1614.106 Labor... EMPLOYMENT OPPORTUNITY Agency Program To Promote Equal Employment Opportunity § 1614.106 Individual... individual and the agency and to describe generally the action(s) or practice(s) that form the basis of the...

  16. Determination of the pipe stemming load

    International Nuclear Information System (INIS)

    Cowin, S.C.

    1979-01-01

    A mechanical model for the emplacement pipe system is developed. The model is then employed to determine the force applied to the surface collar of the emplacement pipe, the pipe-stemming load, and the stress along the emplacement pipe as a function of stemming height. These results are presented as integrals and a method for their numerical integration is given

  17. Lightweight Heat Pipes Made from Magnesium

    Science.gov (United States)

    Rosenfeld, John N.; Zarembo, Sergei N.; Eastman, G. Yale

    2010-01-01

    Magnesium has shown promise as a lighter-weight alternative to the aluminum alloys now used to make the main structural components of axially grooved heat pipes that contain ammonia as the working fluid. Magnesium heat-pipe structures can be fabricated by conventional processes that include extrusion, machining, welding, and bending. The thermal performances of magnesium heat pipes are the same as those of equal-sized aluminum heat pipes. However, by virtue of the lower mass density of magnesium, the magnesium heat pipes weigh 35 percent less. Conceived for use aboard spacecraft, magnesium heat pipes could also be attractive as heat-transfer devices in terrestrial applications in which minimization of weight is sought: examples include radio-communication equipment and laptop computers.

  18. Remote controlled in-pipe manipulators for dye-penetrant inspection and grinding of weld roots inside of pipes

    International Nuclear Information System (INIS)

    Seeberger, E.K.

    2000-01-01

    Technical plants which have to satisfy stringent safety criteria must be continuously kept in line with the state of art. This applies in particular to nuclear power plants. The quality of piping in nuclear power plants has been improved quite considerably in recent years. By virtue of the very high quality requirements fulfilled in the manufacture of medium-carrying and pressure-retaining piping, one of the focal aspects of in-service inspections is the medium wetted inside of the piping. A remote controlled pipe crawler has been developed to allow to perform dye penetrant testing of weld roots inside piping (ID ≥ 150 mm). The light crawler has been designed such that it can be inserted into the piping via valves (gate valves, check valves,...) with their internals removed. Once in the piping, all crawler movements are remotely controlled (horizontal and vertical pipes incl. the elbows). If indications are found these discontinuities are ground according to a qualified procedure using a special grinding head attached to the crawler with complete extraction of all grinding residues. The in-pipe grinding is a special qualified three (3) step performance that ensures no residual tensile stress (less than 50 N/mm 2 ) in the finish machined austenitic material surface. The in-pipe inspection system, qualified according to both the specifications of the German Nuclear Safety Standards Commission (KTA) and the American Society of Mechanical Engineers (ASME), has already been used successfully in nuclear power plants on many occasions. (author)

  19. Thermal stability of the DSC ruthenium dye C106 in robust electrolytes

    DEFF Research Database (Denmark)

    Lund, Torben; Phuong, Nguyen Tuyet; Pechy, Peter

    2014-01-01

    We have investigated the thermal stability of the heteroleptic ruthenium complex C106 employed as a sensitizer in dye-sensitized solar cells. The C106 was adsorbed on TiO2 particles and exposed to 2 different iodide/triidode based redox electrolytes A and B at 80 °C for up to 1500 h in sealed glass......) substitution products 3 and 4 formed by replacement of the thiocyanate ligand by NBB after 1500 h of heating at 80 °C. Samples prepared under ambient conditions gave a steady state C106 concentration of 60% of the initial value and 40% substitution products. The C106 degradation was found to be independent...... of the degree of dye loading of the TiO2 particles and the ratio between the amount of dyed TiO2 particles and electrolyte volume. Assuming that this substitution is the predominant loss mechanism in a DSC during thermal stress, we estimate the reduction in the DSC efficiency after long term heat to be 12...

  20. Heat pipe turbine vane cooling

    Energy Technology Data Exchange (ETDEWEB)

    Langston, L.; Faghri, A. [Univ. of Connecticut, Storrs, CT (United States)

    1995-10-01

    The applicability of using heat pipe principles to cool gas turbine vanes is addressed in this beginning program. This innovative concept involves fitting out the vane interior as a heat pipe and extending the vane into an adjacent heat sink, thus transferring the vane incident heat transfer through the heat pipe to heat sink. This design provides an extremely high heat transfer rate and an uniform temperature along the vane due to the internal change of phase of the heat pipe working fluid. Furthermore, this technology can also eliminate hot spots at the vane leading and trailing edges and increase the vane life by preventing thermal fatigue cracking. There is also the possibility of requiring no bleed air from the compressor, and therefore eliminating engine performance losses resulting from the diversion of compressor discharge air. Significant improvement in gas turbine performance can be achieved by using heat pipe technology in place of conventional air cooled vanes. A detailed numerical analysis of a heat pipe vane will be made and an experimental model will be designed in the first year of this new program.

  1. Laboratory exercises on oscillation modes of pipes

    Science.gov (United States)

    Haeberli, Willy

    2009-03-01

    This paper describes an improved lab setup to study the vibrations of air columns in pipes. Features of the setup include transparent pipes which reveal the position of a movable microphone inside the pipe; excitation of pipe modes with a miniature microphone placed to allow access to the microphone stem for open, closed, or conical pipes; and sound insulation to avoid interference between different setups in a student lab. The suggested experiments on the modes of open, closed, and conical pipes, the transient response of a pipe, and the effect of pipe diameter are suitable for introductory physics laboratories, including laboratories for nonscience majors and music students, and for more advanced undergraduate laboratories. For honors students or for advanced laboratory exercises, the quantitative relation between the resonance width and damping time constant is of interest.

  2. 34 CFR 106.33 - Comparable facilities.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Comparable facilities. 106.33 Section 106.33 Education... Discrimination on the Basis of Sex in Education Programs or Activities Prohibited § 106.33 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but...

  3. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  4. 19 CFR 152.106 - Computed value.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Computed value. 152.106 Section 152.106 Customs... (CONTINUED) CLASSIFICATION AND APPRAISEMENT OF MERCHANDISE Valuation of Merchandise § 152.106 Computed value. (a) Elements. The computed value of imported merchandise is the sum of: (1) The cost or value of the...

  5. IRIG 106 Chapter 10 Programmers Handbook

    Science.gov (United States)

    2016-08-16

    szDataItem. Specific parsers are called for specific attribute types, indicated by the first letter of the code name. After all TMATS attributes are...EnI106Status I106_CALL_DECL enI106Ch10Close(int iHandle) { // If handles have been init’ed then bail if

  6. 9 CFR 3.106 - Water quality.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Water quality. 3.106 Section 3.106... Mammals Animal Health and Husbandry Standards § 3.106 Water quality. (a) General. The primary enclosure... additives (e.g. chlorine and copper) that are added to the water to maintain water quality standards...

  7. Participação dos entes federados no financiamento da saúde bucal de atenção básica: estudo no município da Vitória de Santo Antão, Pernambuco

    Directory of Open Access Journals (Sweden)

    José Eudes de Lorena Sobrinho

    2013-12-01

    Full Text Available O objetivo deste estudo foi mensurar o percentual de participação dos entes federados (União, Estado e Município no financiamento das ações e serviços de saúde bucal na atenção básica no município da Vitória de Santo Antão, Pernambuco, no ano de 2010 a partir da apuração dos custos. Utilizou-se a metodologia do custeio por absorção, tendo sido os custos agrupados em blocos: recursos humanos, recursos materiais e pensos com finalidade odontológica, custos prediais e manutenção de equipamentos. Foram consultados os repasses federais e estaduais através dos sistemas de informação de acesso público (fundo nacional de saúde e fundo estadual de saúde para se estimar a participação dos governos no custeio das ações e serviços de saúde bucal na atenção básica. De um total de R$ 1.340.307,80 (um milhão, trezentos e quarenta mil, trezentos e sete reais e oitenta centavos referentes ao custo total, 37,5% foram relativos a recursos financeiros federais e 62,5% aos municipais, não sendo observada a participação estadual. Constata-se que o município continua sendo o principal provedor do custeio da saúde bucal na atenção básica, direcionando a necessidade de uma articulação interfederativa mais efetiva que assegure o financiamento tripartite.

  8. Fatigue evaluation of piping connections under thermal transients

    International Nuclear Information System (INIS)

    Aquino, C.T.E. de; Maneschy, J.E.

    1993-01-01

    In designing nuclear power plant piping, thermal transients, caused by non-steady operation conditions, should be considered. These events may reduce considerably the lifetime of the pipes, creating the necessity of using structural elements designed in such a way to minimize the acting thermal stresses. Typical examples of the usage of these elements are the connections between pipes of small and large diameters, in which it is usually used a weldolet. Nevertheless, in some situations, the thermal stresses caused by the transients are greater than the allowable limits, being, in this case, an alternative for best results, the introduction of a special fitting replacing the weldolet. Such a fitting is designed in a way to permit a better distribution of the stresses, reducing its maximum value to acceptable levels. This paper intends to present a fatigue evaluation of a connection, using the above mentioned fitting, when subjected to a load expressed in terms of a step thermal gradient, varying from 263 deg to 40 deg C. Two different methodologies are used in this analysis: (a) Determination of the temperature distribution from the heat transfer equations for piping, being the stresses calculated according to ASME III NB-3600. (b) Thermal and stress analyses using axisymmetric elements, according to the rules presented at ASME III NB-3200. In the first case, named simplified analysis, the computer code used is the PIPESTRESS, while in the second case, the ANSYS program was adopted

  9. Seismic analysis of nuclear piping system

    International Nuclear Information System (INIS)

    Shrivastava, S.K.; Pillai, K.R.V.; Nandakumar, S.

    1975-01-01

    To illustrate seismic analysis of nuclear power plant piping, a simple piping system running between two floors of the reactor building is assumed. Reactor building floor response is derived from time-history method. El Centre earthquake (1940) accelerogram is used for time-history analysis. The piping system is analysed as multimass lumped system. Behaviour of the pipe during the said earthquake is discussed. (author)

  10. Failure rates in Barsebaeck-1 reactor coolant pressure boundary piping. An application of a piping failure database

    Energy Technology Data Exchange (ETDEWEB)

    Lydell, B. [RSA Technologies, Vista, CA (United States)

    1999-05-01

    This report documents an application of a piping failure database to estimate the frequency of leak and rupture in reactor coolant pressure boundary piping. The study used Barsebaeck-1 as reference plant. The study tried two different approaches to piping failure rate estimation: 1) PSA-style, simple estimation using Bayesian statistics, and 2) fitting of statistical distribution to failure data. A large, validated database on piping failures (like the SKI-PIPE database) supports both approaches. In addition to documenting leak and rupture frequencies, the SKI report describes the use of piping failure data to estimate frequency of medium and large loss of coolant accidents (LOCAs). This application study was co sponsored by Barsebaeck Kraft AB and SKI Research 41 refs, figs, tabs

  11. Violência no trabalho em saúde: análise em unidades básicas de saúde de Belo Horizonte, Minas Gerais Violence in health work: analysis of basic health units in Belo Horizonte, Minas Gerais

    Directory of Open Access Journals (Sweden)

    Cássia Beatriz Batista

    2011-10-01

    Full Text Available O presente estudo buscou investigar e compreender a violência vivenciada em unidades básicas de saúde (UBSs da perspectiva dos processos de trabalho em saúde. A caracterização da violência nesse contexto, ao identificar e compreender os elementos da produção desse fenômeno, contribui para o seu enfrentamento. De cunho descritivo-exploratório, para a coleta de dados a pesquisa utilizou grupos focais e entrevistas com usuários, trabalhadores e gestores do serviço de saúde. O estudo mostra as consequências e os impactos da violência nas UBSs, retratando atitudes geradas pelos episódios de violência, bem como ações preventivas e mecanismos de apoio e suporte. A análise dos resultados marca a necessidade de se fortalecer não só a humanização e a gestão do trabalho em saúde, mas também a formação dos profissionais, atrelada às melhorias nas condições e no ambiente de trabalho e, consequentemente, na prestação dos serviços de saúde.This study sought to investigate and understand the violence experienced in basic health units (UBS from the perspective of the work processes carried out in health. The characterization of the violence existing in this context, achieved by identifying and understanding the elements that cause this phenomenon, contributes to combating it. Descriptive and exploratory, this study gathered data from focus groups and interviews carried out among health service users, employees and managers. The investigation shows the consequences and impacts of violence in the UBSs, portraying attitudes generated by episodes of violence, as well as preventive actions and mechanisms of support and assistance. The analysis of the results shows not only there is a need both to strengthen the humanization and management of the work in health and to train the area's professionals, but also that these actions should be linked to improved workplace environment and conditions and, thus, better health service

  12. Multiple blowdown pipe experiments with the PPOOLEX facility

    International Nuclear Information System (INIS)

    Puustinen, M.; Laine, J.; Raesaenen, A.

    2011-03-01

    This report summarizes the results of the experiments with two steel blowdown pipes carried out with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through the blowdown pipes to the condensation pool. The main purpose of the experiment series was to study chugging phenomena (rapid condensation) while steam is discharged through two parallel blowdown pipes into the condensation pool filled with sub-cooled water. Particularly, the aim was to study if the pipe material (polycarbonate) used in the earlier experiment series with two blowdown pipes has had an effect on the general chugging behaviour and measured loads. In the experiments the initial temperature of the pool water was 20 deg. C. The steam flow rate ranged from 220 g/s to 2 350 g/s and the temperature of incoming steam from 148 deg. C to 207 deg. C. The formation and collapse of steam bubbles and the movement of the steam/water interface inside the pipes was non-synchronous. There could be even a 70 ms time difference between the occurrences of steam bubble collapses at the outlets of the two pipes. There was no clear pattern in which pipe the steam bubble first starts to collapse. Several successive bubbles could collapse first in either pipe but then the order changed for a single or several cycles. High pressure loads were measured inside the blowdown pipes due to rapid condensation of the steam volumes in the pipes and resulting water hammer effects. The loads seemed to be higher in pipe 1 than in pipe 2. An explanation for this could be a possible unequal distribution of steam flow between the two pipes. The pipe material has an effect on the condensation phenomena inside the blowdown pipes. A huge difference in the measured pressure curves inside the pipes could be observed compared to the experiments with the polycarbonate pipes. With the same test conditions the amplitude of the

  13. Multiple blowdown pipe experiments with the PPOOLEX facility

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, M.; Laine, J.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2011-03-15

    This report summarizes the results of the experiments with two steel blowdown pipes carried out with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through the blowdown pipes to the condensation pool. The main purpose of the experiment series was to study chugging phenomena (rapid condensation) while steam is discharged through two parallel blowdown pipes into the condensation pool filled with sub-cooled water. Particularly, the aim was to study if the pipe material (polycarbonate) used in the earlier experiment series with two blowdown pipes has had an effect on the general chugging behaviour and measured loads. In the experiments the initial temperature of the pool water was 20 deg. C. The steam flow rate ranged from 220 g/s to 2 350 g/s and the temperature of incoming steam from 148 deg. C to 207 deg. C. The formation and collapse of steam bubbles and the movement of the steam/water interface inside the pipes was non-synchronous. There could be even a 70 ms time difference between the occurrences of steam bubble collapses at the outlets of the two pipes. There was no clear pattern in which pipe the steam bubble first starts to collapse. Several successive bubbles could collapse first in either pipe but then the order changed for a single or several cycles. High pressure loads were measured inside the blowdown pipes due to rapid condensation of the steam volumes in the pipes and resulting water hammer effects. The loads seemed to be higher in pipe 1 than in pipe 2. An explanation for this could be a possible unequal distribution of steam flow between the two pipes. The pipe material has an effect on the condensation phenomena inside the blowdown pipes. A huge difference in the measured pressure curves inside the pipes could be observed compared to the experiments with the polycarbonate pipes. With the same test conditions the amplitude of the

  14. Piping data retrieval system (PDRS): An integrated package to aid piping layout

    International Nuclear Information System (INIS)

    Vyas, K.N.; Sharma, A.; Susandhi, R.; Basu, S.

    1986-01-01

    An integrated package to aid piping layout has been developed and implemented on PDP-11/34 system at Hall 7. The package allows various equipments to be modelled, consisting of primitive equipment components. The equipment layout for the plant can then be reproduced in the form of drawings such as plan, elevation, isometric or perspective. The package has the built in function to perform hidden line removal among equipments. Once the equipment layout is finalised, the package aids in superimposing the piping as per the specified pipe routine. The report discusses the general capabilities and the major input requirements for the package. (author)

  15. System and Method for Traversing Pipes

    Science.gov (United States)

    Graf, Jodi (Inventor); Pettinger, Ross (Inventor); Azimi, Shaun (Inventor); Magruder, Darby (Inventor); Ridley, Justin (Inventor); Lapp, Anthony (Inventor)

    2017-01-01

    A system and method is provided for traversing inside one or more pipes. In an embodiment, a fluid is injected into the one or more pipes thereby promoting a fluid flow. An inspection device is deployed into the one or more pipes at least partially filled with a flowing fluid. The inspection device comprises a housing wherein the housing is designed to exploit the hydrokinetic effects associated with a fluid flow in one or more pipes as well as maneuver past a variety of pipe configurations. The inspection device may contain one or more sensors capable of performing a variety of inspection tasks.

  16. Determination of starting materials, intermediates, and subsidiary colors in the color additive Food Red No. 106 (Sulforhodamine B) using high-performance liquid chromatography.

    Science.gov (United States)

    Tatebe, Chiye; Ohtsuki, Takashi; Fujita, Tsuyoshi; Nishiyama, Koji; Itoh, Sumio; Sugimoto, Naoki; Kubota, Hiroki; Tada, Atsuko; Sato, Kyoko; Akiyama, Hiroshi

    2017-12-15

    The main subsidiary color of structure in Food Red No. 106 (R106) was identified to be a desethyl derivative (R106-SubA). High-performance liquid chromatography (HPLC) was performed for the quantitative determination of benzaldehyde-2,4-disulfonic acid, N,N-diethyl-m-aminophenol, leuco acid, pyrone acid, R106-SubA, etc. in R106. An ammonium acetate solution (20mM) and acetonitrile:water (7:3) were used to stabilize the retention time of the HPLC analytes. The linearity of the calibration curves was in the range of 0.05-10μg/mL, with good correlation coefficients (R 2 >0.9983). The recoveries of impurities at levels 0.1%, 0.5% and 1% ranged from 94.2% to 106.6% with relative standard deviations of 0.1%-1.0%. While surveying commercial R106, the amounts obtained by area% determination were similar to those obtained by the calibration-curve determination. The area% determination by HPLC for the determinations of impurities in R106 is a simple and reliable method and can be applied in routine analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Resolution of thermal striping issue downstream of a horizontal pipe elbow in stratified pipe flow

    International Nuclear Information System (INIS)

    Kuzay, T.M.; Kasza, K.E.

    1985-01-01

    A thermally stratified pipe flow produced by a thermal transient when passing through a horizontal elbow as a result of secondary flow gives rise to large thermal fluctuations on the inner curvature wall of the downstream piping. These fluctuations were measured in a specially instrumented horizontal pipe and elbow system on a test set-up using water in the Mixing Components Technology Facility (MCTF) at Argonne National Laboratory (ANL). This study is part of a larger program which is studying the influence of thermal buoyancy on general reactor component performance. This paper discusses the influence of pipe flow generated thermal oscillations on the thermal stresses induced in the pipe walls. The instrumentation was concentrated around the exit plane of the 90 0 sweep elbow, since prior tests had indicated that the largest thermal fluctuations would occur within about one hydraulic diameter downstream of the elbow exit. The thermocouples were located along the inner curvature of the piping and measured the near surface fluid temperature. The test matrix involved thermal downramps under turbulent flow conditions

  18. Senescência e senilidade: novo paradigma na atenção básica de saúde

    Directory of Open Access Journals (Sweden)

    Suely Itsuko Ciosak

    2011-12-01

    Full Text Available A senescência e a senilidade são temas cada vez mais explorados, considerando o crescente aumento da população idosa no mundo, principalmente no Brasil. A assistência ao idoso deve prezar pela manutenção da qualidade de vida, considerando o processo de perdas próprias do envelhecimento e as possibilidades de prevenção, manutenção e reabilitação do seu estado de saúde. Conhecer o cotidiano dos idosos tem sido um desafio para os profissionais de saúde para implementar programas e ações que visem alcançar a manutenção do equilíbrio no processo saúde-doença, e é nessa busca que temos envidado esforços para contribuir, de forma efetiva, nas estratégias de fortalecimento dos idosos e seus familiares, de forma a tornar possível o desencadeamento de ações na promoção da saúde, principalmente considerando que o desafio para este milênio é construir uma consciência coletiva para alcançar uma sociedade para todas as idades, com justiça e garantia plena de direitos.

  19. Characterization of radioactive contamination inside pipes with the Pipe Explorer{trademark} system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, C.D.; Kendrick, D.T.; Lowry, W.; Cramer, E.

    1997-09-30

    The Department of Energy (DOE) is currently in the process of decommissioning and dismantling many of its nuclear materials processing facilities that have been in use for several decades. Site managers throughout the DOE complex must employ the safest and most cost effective means to characterize, remediate and recycle or dispose of hundreds of miles of potentially contaminated piping and duct work. The DOE discovered that standard characterization methods were inadequate for its pipes, drains, and ducts because many of the systems are buried or encased. In response to the DOE`s need for a more specialized characterization technique, Science and Engineering Associates, Inc. (SEA) developed the Pipe Explorer{trademark} system through a DOE Office of Science and Technology (OST) contract administered through the Federal Energy Technology Center (FETC). The purpose of this report is to serve as a comprehensive overview of all phases of the Pipe Explorer{trademark} development project. The report is divided into 6 sections. Section 2 of the report provides an overview of the Pipe Explorer{trademark} system, including the operating principles of using an inverting membrane to tow sensors into pipes. The basic components of the characterization system are also described. Descriptions of the various deployment systems are given in Section 3 along with descriptions of the capabilities of the deployment systems. During the course of the development project 7 types of survey instruments were demonstrated with the Pipe Explorer{trademark} and are a part of the basic toolbox of instruments available for use with the system. These survey tools are described in Section 4 along with their typical performance specifications. The 4 demonstrations of the system are described chronologically in Section 5. The report concludes with a summary of the history, status, and future of the Pipe Explorer{trademark} system in Section 6.

  20. Characterization of radioactive contamination inside pipes with the Pipe Explorer trademark system. Final report

    International Nuclear Information System (INIS)

    Cremer, C.D.; Kendrick, D.T.; Lowry, W.; Cramer, E.

    1997-01-01

    The Department of Energy (DOE) is currently in the process of decommissioning and dismantling many of its nuclear materials processing facilities that have been in use for several decades. Site managers throughout the DOE complex must employ the safest and most cost effective means to characterize, remediate and recycle or dispose of hundreds of miles of potentially contaminated piping and duct work. The DOE discovered that standard characterization methods were inadequate for its pipes, drains, and ducts because many of the systems are buried or encased. In response to the DOE's need for a more specialized characterization technique, Science and Engineering Associates, Inc. (SEA) developed the Pipe Explorer trademark system through a DOE Office of Science and Technology (OST) contract administered through the Federal Energy Technology Center (FETC). The purpose of this report is to serve as a comprehensive overview of all phases of the Pipe Explorer trademark development project. The report is divided into 6 sections. Section 2 of the report provides an overview of the Pipe Explorer trademark system, including the operating principles of using an inverting membrane to tow sensors into pipes. The basic components of the characterization system are also described. Descriptions of the various deployment systems are given in Section 3 along with descriptions of the capabilities of the deployment systems. During the course of the development project 7 types of survey instruments were demonstrated with the Pipe Explorer trademark and are a part of the basic toolbox of instruments available for use with the system. These survey tools are described in Section 4 along with their typical performance specifications. The 4 demonstrations of the system are described chronologically in Section 5. The report concludes with a summary of the history, status, and future of the Pipe Explorer trademark system in Section 6

  1. 12 CFR 347.106 - Going concerns.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Going concerns. 347.106 Section 347.106 Banks... INTERNATIONAL BANKING § 347.106 Going concerns. Going concerns. If a bank acquires an equity interest in a foreign organization that is a going concern, no more than 5 percent of either the consolidated assets or...

  2. Acidente com material biológico no atendimento pré-hospitalar móvel: realidade para trabalhadores da saúde e não saúde

    OpenAIRE

    Tipple, Anaclara Ferreira Veiga; Silva, Elisangelo Aparecido Costa; Teles, Sheila Araújo; Mendonça, Katiane Martins; Souza, Adenícia Custódia Silva e; Melo, Dulcelene Sousa

    2013-01-01

    Estudo analítico transversal, com objetivos de identificar a prevalência e caracterizar os acidentes com material biológico entre profissionais do Atendimento Pré-Hospitalar (APH) e comparar os comportamentos de risco adotados entre os grupos saúde e não saúde que podem influenciar na ocorrência e na gravidade destes acidentes. Dados foram obtidos por meio de questionário aplicado a todos os trabalhadores do APH de Goiânia - GO. Verificou-se alta prevalência de acidentes envolvendo material b...

  3. Lifetime measurements of the first 2+ states in 104,106Zr: Evolution of ground-state deformations

    Directory of Open Access Journals (Sweden)

    F. Browne

    2015-11-01

    Full Text Available The first fast-timing measurements from nuclides produced via the in-flight fission mechanism are reported. The lifetimes of the first 2+ states in 104,106Zr nuclei have been measured via β-delayed γ-ray timing of stopped radioactive isotope beams. An improved precision for the lifetime of the 21+ state in 104Zr was obtained, τ(21+=2.90−20+25 ns, as well as a first measurement of the 21+ state in 106Zr, τ(21+=2.60−15+20 ns, with corresponding reduced transition probabilities of B(E2;21+→0g.s.+=0.39(2 e2b2 and 0.31(1 e2b2, respectively. Comparisons of the extracted ground-state deformations, β2=0.39(1 (104Zr and β2=0.36(1 (106Zr with model calculations indicate a persistence of prolate deformation. The data show that 104Zr is the most deformed of the neutron-rich Zr isotopes measured so far.

  4. Superconducting pipes and levitating magnets.

    Science.gov (United States)

    Levin, Yan; Rizzato, Felipe B

    2006-12-01

    Motivated by a beautiful demonstration of the Faraday and the Lenz laws in which a small neodymium magnet falls slowly through a conducting nonferromagnetic tube, we consider the dynamics of a magnet falling coaxially through a superconducting pipe. Unlike the case of normal conducting pipes, in which the magnet quickly reaches the terminal velocity, inside a superconducting tube the magnet falls freely. On the other hand, to enter the pipe the magnet must overcome a large electromagnetic energy barrier. For sufficiently strong magnets, the barrier is so large that the magnet will not be able to penetrate it and will be levitated over the mouth of the pipe. We calculate the work that must done to force the magnet to enter a superconducting tube. The calculations show that superconducting pipes are very efficient at screening magnetic fields. For example, the magnetic field of a dipole at the center of a short pipe of radius a and length L approximately > a decays, in the axial direction, with a characteristic length xi approximately 0.26a. The efficient screening of the magnetic field might be useful for shielding highly sensitive superconducting quantum interference devices. Finally, the motion of the magnet through a superconducting pipe is compared and contrasted to the flow of ions through a trans-membrane channel.

  5. Utilization of SA-gal as clearing agent in pre-targeting RII of colon carcinoma xenograft bearing models

    International Nuclear Information System (INIS)

    Wu Hubing; Huang Zuhan; Peng Wuhe; Gao Xiao

    2001-01-01

    Objective: To conjugate galactose streptavidin (SA-gal) and use it as a clearing agent in pre-targeting radioimmunoimaging (RII) of colon carcinoma xenograft models. Methods: SA-gal was obtained by incubating galactose moiety with streptavidin at a molar ratio of 45 : 1. For imaging in vivo, biotinylated antibody radiolabelled with 131 I was injected into the nude mice bearing the colon carcinoma xenograft via the tail vein. 24 h later, SA-gal were intraperitoneally injected at a ratio of 10-fold (molar) excess to antibody. At 0.5 h and 6 h after SA-gal administration, the animals of different test groups were killed for biodistribution study or imaging. No clearing agent was administrated to the animals of two control groups and they were also killed for biodistribution study or imaging at 24 h or 30 h after injection of 131 I labelled antibody. Results: 1) Galactose moiety was bound to SA at a molar ratio of 20 : 1. 2) In pre-targeting RII, SA-gal undertook the chase effect very fast. At 0.5 h after injection, the blood level of radioactivity decreased very fast and tumor-to-blood (T/B) ratio increased from 0.32 to 1.44. At 6 h after SA-gal administration, T/B ratio reached 5.23, significantly higher than 0.41 of the control group (P 131 I-biotinylated antitumor antibody RII

  6. Experimental observations of thermal mixing characteristics in T-junction piping

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Mei-Shiue, E-mail: chenms@mx.nthu.edu.tw; Hsieh, Huai-En; Ferng, Yuh-Ming; Pei, Bau-Shi

    2014-09-15

    Highlights: • The effects of flow velocity ratio on thermal mixing phenomenon are the major parameters. • The flow velocity ratio (V{sub b}/V{sub m}) is greater than 13.6, reverse flow occurs. • The flow velocity ratio is greater than 13.7, a “good” mixing quality is achieved. - Abstract: The T-junction piping is frequently used in many industrial applications, including the nuclear plants. For a pressurized water reactor (PWR), the emergency core cooling systems (ECCS) inject cold water into the primary loops if a loss-of-coolant accident (LOCA) happens. Inappropriate mixing of the two streams with significant temperature different at a junction may cause strong thermal stresses to the downstream structures in the reactor vessel. The downstream structures may be damaged. This study is an experimental investigation into the thermal mixing effect occurring at a T-junction. A small-scale test facility was established to observe the mixing effect of flows with different temperature. Thermal mixing effect with different flow rates in the main and branch pipes are investigated by measuring the temperature distribution along the main pipe. In test condition I, we found that lower main pipe flow rate leads to better mixing effect with constant branch pipe flow rate. And in conditions II and III, higher injection flow velocity would enhance the turbulence effect which results in better thermal mixing. The results will be useful for applications with mixing fluids with different temperature.

  7. Evaluation of clamp effects on LMFBR piping systems

    International Nuclear Information System (INIS)

    Jones, G.L.

    1980-01-01

    Loop-type liquid metal breeder reactor plants utilize thin-wall piping to mitigate through-wall thermal gradients due to rapid thermal transients. These piping loops require a support system to carry the combined weight of the pipe, coolant and insulation and to provide attachments for seismic restraints. The support system examined here utilizes an insulated pipe clamp designed to minimize the stresses induced in the piping. To determine the effect of these clamps on the pipe wall a non-linear, two-dimensional, finite element model of the clamp, insulation and pipe wall was used to determine the clamp/pipe interface load distributions which were then applied to a three-dimensional, finite element model of the pipe. The two-dimensional interaction model was also utilized to estimate the combined clamp/pipe stiffness

  8. Health and poverty: health management by the woman Salud y pobreza: el control de la salud por la mujer Saúde e pobreza: o controle da saúde pela mulher

    Directory of Open Access Journals (Sweden)

    Maria de la Luz Alvarez

    1992-04-01

    Full Text Available The goal this follow-up study was to relate the mother's marital satisfaction to family health status in a low SES. The random sample was made up of 30 families with children under 7 years old: 15 considered as sick (Group A and 15 as healthy (Group B. Both group had similar demographic characteristics (age of father and mother, persons per family group and age of children and SES. Results showed that mothers were those mainly in charge of their family groups. Mothers of Group A were significantly less understanding and more dissatisfied than those of Group B ( p El objetivo de este estudio de seguimiento fue relacionar la satisfacción de la madre en su vida marital con el estado de salud de su familia en el nivel socioeconómico (NSE bajo. La muestra estuvo formada por 30 familias con niños menores de 7 años: 15 consideradas "enfermas" (Grupo A y 15 "sanas" (Grupo B. Ambos grupos eran similares en sus características demográficas (edad del padre y de la madre, nº de personas en el grupo familiar y edad de los hijos y NSE. Los resultados mostraron que las madres eran principalmente las encargadas de la salud familiar. Las madres del Grupo A eran significativamente menos comprendidas y más insatisfechas que aquellas del Grupo B (p Foi realizado estudo prospectivo relacionando a satisfação da mãe com sua vida marital e o estado de saúde da família de nível socioeconômico baixo. A amostra estudada consistiu de 30 famílias com crianças menores de 7 anos: 15 consideradas "doentes" (grupo A e 15 "sãs" (grupo B. Os dois grupos não diferiram em relação à idade dos pais, número de pessoas na família, idade das crianças e nível socioeconômico. Os resultados mostraram que as mães eram responsáveis pela saúde da família. As do grupo A eram significativamente menos compreendidas e eram menos satisfeitas que as do grupo B (p < 0,05 e p < 0,01. As mães do grupo A brigavam mais com seus parceiros (p < 0,006 do que as do grupo B

  9. Fatigue crack growth rate studies on pipes and pipe welds made of austenitic stainless steel and carbon steel

    International Nuclear Information System (INIS)

    Arora, Punit; Singh, P.K.; Bhasin, Vivek; Vaze, K.K.; Pukazhendhi, D.M.; Gandhi, P.; Raghava, G.

    2011-01-01

    The objective of the present study is to understand the fatigue crack growth behavior in austenitic stainless steel and carbon steel pipes and pipe welds by carrying out analysis/predictions and experiments. The Paris law has been used for the prediction of fatigue crack growth life. To carry out the analysis, Paris constants have been determined for pipe (base) and pipe weld materials by using Compact Tension (CT)/Three Point Bend (TPB) specimens machined from the actual pipe/pipe weld. Analyses have been carried out to predict the fatigue crack growth life of pipes/pipe welds having part through cracks on the outer surface. In the analyses, Stress Intensity Factors (K) have been evaluated through two different schemes. The first scheme considers the 'K' evaluations at two points of the crack front i.e. maximum crack depth and crack tip at the outer surface. The second scheme accounts for the area averaged root mean square stress intensity factor (K RMS ) at deepest and surface points. In order to validate the analytical procedure/results, experiments have been carried out on full scale pipe and pipe welds with part through circumferential crack. Fatigue crack growth life evaluated using both schemes have been compared with experimental results. Use of stress intensity factor (K RMS ) evaluated using second scheme gives better fatigue crack growth life prediction compared to that of first scheme. (author)

  10. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A

    2011-01-01

    Pipe Drafting and Design, Third Edition provides step-by-step instructions to walk pipe designers, drafters, and students through the creation of piping arrangement and isometric drawings. It includes instructions for the proper drawing of symbols for fittings, flanges, valves, and mechanical equipment. More than 350 illustrations and photographs provide examples and visual instructions. A unique feature is the systematic arrangement of drawings that begins with the layout of the structural foundations of a facility and continues through to the development of a 3-D model. Advanced chapters

  11. Assessment of cracked pipes in primary piping systems of PWR nuclear reactors

    International Nuclear Information System (INIS)

    Jong, Rudolf Peter de

    2004-01-01

    Pipes related to the Primary System of Pressurized Water Reactors (PWR) are manufactured from high toughness austenitic and low alloy ferritic steels, which are resistant to the unstable growth of defects. A crack in a piping system should cause a leakage in a considerable rate allowing its identification, before its growth could cause a catastrophic rupture of the piping. This is the LBB (Leak Before Break) concept. An essential step in applying the LBB concept consists in the analysis of the stability of a postulated through wall crack in a specific piping system. The methods for the assessment of flawed components fabricated from ductile materials require the use of Elasto-Plastic Fracture Mechanics (EPFM). Considering that the use of numerical methods to apply the concepts of EPFM may be expensive and time consuming, the existence of the so called simplified methods for the assessment of flaws in piping are still considered of great relevance. In this work, some of the simplified methods, normalized procedures and criteria for the assessment of the ductile behavior of flawed components available in literature are described and evaluated. Aspects related to the selection of the material properties necessary for the application of these methods are also discussed. In a next .step, the methods are applied to determine the instability load in some piping configurations under bending and containing circumferential through wall cracks. Geometry and material variations are considered. The instability loads, obtained for these piping as the result of the application of the selected methods, are analyzed and compared among them and with some experimental results obtained from literature. The predictions done with the methods demonstrated that they provide consistent results, with good level of accuracy with regard to the determination of maximum loads. These methods are also applied to a specific Study Case. The obtained results are then analyzed in order to give

  12. Development of bore tools for pipe inspection

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Nakahira, Masataka; Taguchi, Kou; Ito, Akira [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    In the International Thermonuclear Reactor (ITER), replacement and maintenance on in-vessel components requires that all cooling pipes connected be cut and removed, that a new component be installed, and that all cooling pipes be rewelded. After welding is completed, welded area must be inspected for soundness. These tasks require a new work concept for securing shielded area and access from narrow ports. Tools had to be developed for nondestructive inspection and leak testing to evaluate pipe welding soundness by accessing areas from inside pipes using autonomous locomotion welding and cutting tools. A system was proposed for nondestructive inspection of branch pipes and the main pipe after passing through pipe curves, the same as for welding and cutting tool development. Nondestructive inspection and leak testing sensors were developed and the basic parameters were obtained. In addition, the inspection systems which can move inside pipes and conduct the nondestructive inspection and the leak testing were developed. In this paper, an introduction will be given to the current situation concerning the development of nondestructive inspection and leak testing machines for the branch pipes. (author)

  13. Evaluating the B-cell density with various activation functions using White Noise Path Integral Approach

    Science.gov (United States)

    Aban, C. J. G.; Bacolod, R. O.; Confesor, M. N. P.

    2015-06-01

    A The White Noise Path Integral Approach is used in evaluating the B-cell density or the number of B-cell per unit volume for a basic type of immune system response based on the modeling done by Perelson and Wiegel. From the scaling principles of Perelson [1], the B- cell density is obtained where antigens and antibodies mutates and activation function f(|S-SA|) is defined describing the interaction between a specific antigen and a B-cell. If the activation function f(|S-SA|) is held constant, the major form of the B-cell density evaluated using white noise analysis is similar to the form of the B-cell density obtained by Perelson and Wiegel using a differential approach.A piecewise linear functionis also used to describe the activation f(|S-SA|). If f(|S-SA|) is zero, the density decreases exponentially. If f(|S-SA|) = S-SA-SB, the B- cell density increases exponentially until it reaches a certain maximum value. For f(|S-SA|) = 2SA-SB-S, the behavior of B-cell density is oscillating and remains to be in small values.

  14. Review of nuclear piping seismic design requirements

    International Nuclear Information System (INIS)

    Slagis, G.C.; Moore, S.E.

    1994-01-01

    Modern-day nuclear plant piping systems are designed with a large number of seismic supports and snubbers that may be detrimental to plant reliability. Experimental tests have demonstrated the inherent ruggedness of ductile steel piping for seismic loading. Present methods to predict seismic loads on piping are based on linear-elastic analysis methods with low damping. These methods overpredict the seismic response of ductile steel pipe. Section III of the ASME Boiler and Pressure Vessel Code stresses limits for piping systems that are based on considerations of static loads and hence are overly conservative. Appropriate stress limits for seismic loads on piping should be incorporated into the code to allow more flexible piping designs. The existing requirements and methods for seismic design of piping systems, including inherent conservations, are explained to provide a technical foundation for modifications to those requirements. 30 refs., 5 figs., 3 tabs

  15. The stability of growth of a through-wall circumferential crack in a cylindrical pipe subjected to bending deformation

    International Nuclear Information System (INIS)

    Smith, E.

    1987-01-01

    Tada, Paris and Gamble have used the tearing modulus approach to examine the stability of growth of a through-wall circumferential crack in a 304 stainless steel circular cylindrical pipe subject to bending deformation. They showed that crack growth is stable, in the sense that growth requires the rotation imposed at the pipe-ends to be increased, provided the pipe length is less than a critical length Lsub(c), which is given by their analysis. The Tada-Paris-Gamble analysis focuses on the question of the stability, or otherwise, of crack growth at the onset of crack extension. The analysis does not consider the possibilities that (a) instability might occur after some stable crack growth, and (b) arrest might occur after some unstable growth. A study of these aspects of the circumferential crack growth problem using the tearing modulus approach is precluded by the geometry dependence of the J-crack growth resistance curve. Consequently the present paper uses a crack tip opening angle criterion to describe crack growth, and thereby demonstrates that possibilities (a) and (b) should both occur, depending on the initial crack length and pipe length. In terms of relevance to the technologically important problem of cracking in Boiling Water Reactor piping, the important conclusion stemming from the paper's analysis is that stability of crack growth after the onset of crack extension is assured if the pipe length is less than a critical length L'sub(c). L'sub(c) is less than Lsub(c), the critical length relevant to the onset of crack extension, but it is still appreciably greater than the pipe run lengths in actual reactor piping systems, and safety against guillotine failure of a pipe is therefore generally assured. (author)

  16. Flow induced vibrations of piping

    International Nuclear Information System (INIS)

    Gibert, R.J.; Axisa, F.

    1977-01-01

    In order to design the supports of piping systems, estimations of the vibrations induced by the fluid conveyed through the pipes are generally needed. For that purpose it is necessary to calculate the model parameters of liquid containing pipes. In most computer codes, fluid effects are accounted for just by adding the fluid mass to the structure. This may lead to serious errors. This paper presents a method to take into account these effects, by solving a coupled mechanical-acoustical problem: the computer code TEDEL of the C.E.A /D.E.M.T. System, based on the finite-elements method, has been extended to calculate simultaneously the pressure fluctuations in the fluid and the vibrations of the pipe. By this way the mechanical-acoustical coupled eigenmodes of any piping system can be obtained. These eigenmodes are used to determine the response of the system to various sources. Equations have been written in the hypohesis that acoustical wave lengths remain large compared to the diameter of the pipe. The method has been checked by an experiment performed on the GASCOGNE loop at D.E.M.T. The piping system under test consists of a tube with four elbows. The circuit is ended at each extremity by a large vessel which performs acoustical isolation by generating modes for the pressure. Excitation of the circuit is caused by a valve located near the downstream vessel. This provides an efficient localised broad band acoustical source. The comparison between the test results and the calculations has shown that the low frequency resonant characteristics of the pipe and the vibrational amplitude at various flow-rates can be correctly predicted

  17. Some research in the field of leak before break criteria for piping

    International Nuclear Information System (INIS)

    Lazzeri, L.

    1984-01-01

    Leak-before-break research activity has lead to the following basic results: a) From an extensive analysis of the available experimental data it is concluded that the concept of net section collapse is a simple, reliable, valid tool in the case of very ductile materials. b) The analysis of some experimental data has lead to the conclusion that for partially ductile materials mixed ductile, fragile conditions may be present. c) From the analyses at a and b criteria have been established in order to compute collapse conditions for through cracked pipes as a function of the applied load (moment and axial load) in terms of net section collapse. d) The role of the thermal and secondary self equilibrating loads is discussed. e) The leak areas are often evaluated on the basis of the 0.1 Aflow criterion, i.e. somewhat arbitrarily assuming a leak area equal to 10% the pipe flow area. f) The 0.1 Aflow criteria is applied to typical lines, and it is concluded that such loads can be taken without using the classical pipe whip restraints, even if some increase in the size of the snubbers might be necessary

  18. Functional capability of piping systems

    International Nuclear Information System (INIS)

    Terao, D.; Rodabaugh, E.C.

    1992-11-01

    General Design Criterion I of Appendix A to Part 50 of Title 10 of the Code of Federal Regulations requires, in part, that structures, systems, and components important to safety be designed to withstand the effects of earthquakes without a loss of capability to perform their safety function. ne function of a piping system is to convey fluids from one location to another. The functional capability of a piping system might be lost if, for example, the cross-sectional flow area of the pipe were deformed to such an extent that the required flow through the pipe would be restricted. The objective of this report is to examine the present rules in the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, and potential changes to these rules, to determine if they are adequate for ensuring the functional capability of safety-related piping systems in nuclear power plants

  19. Promethus Hot Leg Piping Concept

    International Nuclear Information System (INIS)

    AM Girbik; PA Dilorenzo

    2006-01-01

    The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept

  20. Soil-pipe interaction modeling for pipe behavior prediction with super learning based methods

    Science.gov (United States)

    Shi, Fang; Peng, Xiang; Liu, Huan; Hu, Yafei; Liu, Zheng; Li, Eric

    2018-03-01

    Underground pipelines are subject to severe distress from the surrounding expansive soil. To investigate the structural response of water mains to varying soil movements, field data, including pipe wall strains in situ soil water content, soil pressure and temperature, was collected. The research on monitoring data analysis has been reported, but the relationship between soil properties and pipe deformation has not been well-interpreted. To characterize the relationship between soil property and pipe deformation, this paper presents a super learning based approach combining feature selection algorithms to predict the water mains structural behavior in different soil environments. Furthermore, automatic variable selection method, e.i. recursive feature elimination algorithm, were used to identify the critical predictors contributing to the pipe deformations. To investigate the adaptability of super learning to different predictive models, this research employed super learning based methods to three different datasets. The predictive performance was evaluated by R-squared, root-mean-square error and mean absolute error. Based on the prediction performance evaluation, the superiority of super learning was validated and demonstrated by predicting three types of pipe deformations accurately. In addition, a comprehensive understand of the water mains working environments becomes possible.

  1. Pipe line construction for reactor containment buildings

    International Nuclear Information System (INIS)

    Aoki, Masataka; Yoshinaga, Toshiaki

    1978-01-01

    Purpose: To prevent the missile phenomenon caused by broken fragments due to pipe whip phenomenon in a portion of pipe lines connected to a reactor containment from prevailing to other portions. Constitution: Various pipe lines connected to the pressure vessel are disposed at the outside of the containments and they are surrounded with a plurality of protection partition walls respectively independent from each other. This can eliminate the effect of missile phenomena upon pipe rupture from prevailing to the pipe lines and instruments. Furthermore this can afford sufficient spaces for the pipe lines, as well as for earthquake-proof supports. (Horiuchi, T.)

  2. Study of verification and validation of standard welding procedure specifications guidelines for API 5L X-70 grade line pipe welding

    Directory of Open Access Journals (Sweden)

    Qazi H. A. A.

    2017-12-01

    Full Text Available Verification and validation of welding procedure specifications for X-70 grade line pipe welding was performed as per clause 8.2, Annexure B and D of API 5L, 45th Edition to check weld integrity in its future application conditions. Hot rolled coils were imported from China, de-coiling, strip edge milling, three roller bending to from pipe, inside and outside submerged arc welding of pipe, online ultrasonic testing of weld, HAZ and pipe body, cutting at fixed random length of pipe, visual inspection of pipe, Fluoroscopic inspection of pipe, welding procedure qualification test pieces marking at weld portion of the pipe, tensile testing, guided bend testing, CVN Impact testing were performed. Detailed study was conducted to explore possible explanations and variation in mechanical properties, WPS is examined and qualified as per API 5L 45th Edition.

  3. Saúde e meio ambiente nas cidades: os desafios da saúde ambiental

    Directory of Open Access Journals (Sweden)

    Nelson Gouveia

    1999-02-01

    Full Text Available Dentro de alguns poucos anos, nosso planeta contará com mais habitantes em áreas urbanas do que em áreas rurais. A urbanização desenfreada, sem mecanismos regulatórios e de controle, típica dos países periféricos, trouxe consigo enormes repercussões na saúde da população. Problemas como a insuficiência dos serviços básicos de saneamento, coleta e destinação adequada do lixo e condições precárias de moradia, tradicionalmente relacionados com a pobreza e o subdesenvolvimento, somam-se agora à poluição química e física do ar, da água e da terra, problemas ambientais antes considerados "modernos". Novamente, é sobre as populações mais carentes que recai a maior parte dos efeitos negativos da urbanização, gerando uma situação de extrema desigualdade e iniqüidade ambiental e em saúde. Para reverter esse quadro é preciso que haja uma reincorporação das questões do meio ambiente nas políticas de saúde, e a integração dos objetivos da saúde ambiental numa ampla estratégia de desenvolvimento sustentável. Uma abordagem mais integrada, com mecanismos intersetoriais que possibilitem um diálogo amplo entre as partes, trará enormes benefícios na conquista de melhores condições de vida nas cidades. A saúde ambiental hoje tem o desafio de promover uma melhor qualidade de vida e saúde nas cidades e a oportunidade de enfrentar o absurdo quadro de exclusão social, sob a perspectiva da eqüidade.In a matter of few years there will be more urban than rural dwellers worldwide. The rapid urbanisation lacking adequate control and regulatory mechanisms typical of developing countries, brought along huge effects to the health of the population Environmental problems traditionally related to poverty and underdevelopment such as insufficient provision of sanitation services, waste collection and disposal, and precarious housing conditions, are now added to environmental problems considered of "modern life" such as the

  4. Short cracks in piping and piping welds. Seventh program report, March 1993-December 1994. Volume 4, Number 1

    Energy Technology Data Exchange (ETDEWEB)

    Wilkowski, G.M.; Ghadiali, N.; Rudland, D.; Krishnaswamy, P.; Rahman, S.; Scott, P. [Battelle, Columbus, OH (United States)

    1995-04-01

    This is the seventh progress report of the U.S. Nuclear Regulatory Commission`s research program entitled {open_quotes}Short Cracks in Piping and Piping Welds{close_quotes}. The program objective is to verify and improve fracture analyses for circumferentially cracked large-diameter nuclear piping with crack sizes typically used in leak-before-break (LBB) analyses and in-service flaw evaluations. All work in the eight technical tasks have been completed. Ten topical reports are scheduled to be published. Progress only during the reporting period, March 1993 - December 1994, not covered in the topical reports is presented in this report. Details about the following efforts are covered in this report: (1) Improvements to the two computer programs NRCPIPE and NRCPIPES to assess the failure behavior of circumferential through-wall and surface-cracked pipe, respectively; (2) Pipe material property database PIFRAC; (3) Circumferentially cracked pipe database CIRCUMCK.WKI; (4) An assessment of the proposed ASME Section III design stress rule changes on pipe flaw tolerance; and (5) A pipe fracture experiment on a section of pipe removed from service degraded by microbiologically induced corrosion (MIC) which contained a girth weld crack. Progress in the other tasks is not repeated here as it has been covered in great detail in the topical reports.

  5. Short cracks in piping and piping welds. Seventh program report, March 1993-December 1994. Volume 4, Number 1

    International Nuclear Information System (INIS)

    Wilkowski, G.M.; Ghadiali, N.; Rudland, D.; Krishnaswamy, P.; Rahman, S.; Scott, P.

    1995-04-01

    This is the seventh progress report of the U.S. Nuclear Regulatory Commission's research program entitled open-quotes Short Cracks in Piping and Piping Weldsclose quotes. The program objective is to verify and improve fracture analyses for circumferentially cracked large-diameter nuclear piping with crack sizes typically used in leak-before-break (LBB) analyses and in-service flaw evaluations. All work in the eight technical tasks have been completed. Ten topical reports are scheduled to be published. Progress only during the reporting period, March 1993 - December 1994, not covered in the topical reports is presented in this report. Details about the following efforts are covered in this report: (1) Improvements to the two computer programs NRCPIPE and NRCPIPES to assess the failure behavior of circumferential through-wall and surface-cracked pipe, respectively; (2) Pipe material property database PIFRAC; (3) Circumferentially cracked pipe database CIRCUMCK.WKI; (4) An assessment of the proposed ASME Section III design stress rule changes on pipe flaw tolerance; and (5) A pipe fracture experiment on a section of pipe removed from service degraded by microbiologically induced corrosion (MIC) which contained a girth weld crack. Progress in the other tasks is not repeated here as it has been covered in great detail in the topical reports

  6. Estimates of relative doses of {sup 106}Ru/{sup 106}Rh of spherical applicators used in ophthalmic brachytherapy; Estimativas de doses relativas de aplicadores esfericos de {sup 106}Ru/{sup 106}Rh usados em braquiterapia oftalmologica

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Eduardo de, E-mail: edup2112@gmail.com, E-mail: epaiva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Fisica Medica

    2016-11-01

    Spherical ophthalmic applicators containing the beta emitter {sup 106}Ru / {sup 106}Rh are much used in brachytherapy for the treatment of various eye diseases. However, there is great difficulty in dosimetry these sources because of its geometric shape, the short range of the beta particles and the large dose gradient, and because of that calculation methods of dose distributions around these sources take on a great importance. In this work an analytical / numerical method is used to estimate the dose rates for a function of depth for spherical sources containing {sup 106}Ru / {sup 106}Rh. The results of the doses on along the central axis for applicators models CXS, CCX, CCY, CCZ, CCD and CGD and CCC are compared with published values calculated by Monte Carlo simulation and measurement results.

  7. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  8. Chemical laser exhaust pipe design research

    Science.gov (United States)

    Sun, Yunqiang; Huang, Zhilong; Chen, Zhiqiang; Ren, Zebin; Guo, Longde

    2016-10-01

    In order to weaken the chemical laser exhaust gas influence of the optical transmission, a vent pipe is advised to emissions gas to the outside of the optical transmission area. Based on a variety of exhaust pipe design, a flow field characteristic of the pipe is carried out by numerical simulation and analysis in detail. The research results show that for uniform deflating exhaust pipe, although the pipeline structure is cyclical and convenient for engineering implementation, but there is a phenomenon of air reflows at the pipeline entrance slit which can be deduced from the numerical simulation results. So, this type of pipeline structure does not guarantee seal. For the design scheme of putting the pipeline contract part at the end of the exhaust pipe, or using the method of local area or tail contraction, numerical simulation results show that backflow phenomenon still exists at the pipeline entrance slit. Preliminary analysis indicates that the contraction of pipe would result in higher static pressure near the wall for the low speed flow field, so as to produce counter pressure gradient at the entrance slit. In order to eliminate backflow phenomenon at the pipe entrance slit, concerned with the pipeline type of radial size increase gradually along the flow, flow field property in the pipe is analyzed in detail by numerical simulation methods. Numerical simulation results indicate that there is not reflow phenomenon at entrance slit of the dilated duct. However the cold air inhaled in the slit which makes the temperature of the channel wall is lower than the center temperature. Therefore, this kind of pipeline structure can not only prevent the leak of the gas, but also reduce the wall temperature. In addition, compared with the straight pipe connection way, dilated pipe structure also has periodic structure, which can facilitate system integration installation.

  9. Asymptotic scalings of developing curved pipe flow

    Science.gov (United States)

    Ault, Jesse; Chen, Kevin; Stone, Howard

    2015-11-01

    Asymptotic velocity and pressure scalings are identified for the developing curved pipe flow problem in the limit of small pipe curvature and high Reynolds numbers. The continuity and Navier-Stokes equations in toroidal coordinates are linearized about Dean's analytical curved pipe flow solution (Dean 1927). Applying appropriate scaling arguments to the perturbation pressure and velocity components and taking the limits of small curvature and large Reynolds number yields a set of governing equations and boundary conditions for the perturbations, independent of any Reynolds number and pipe curvature dependence. Direct numerical simulations are used to confirm these scaling arguments. Fully developed straight pipe flow is simulated entering a curved pipe section for a range of Reynolds numbers and pipe-to-curvature radius ratios. The maximum values of the axial and secondary velocity perturbation components along with the maximum value of the pressure perturbation are plotted along the curved pipe section. The results collapse when the scaling arguments are applied. The numerically solved decay of the velocity perturbation is also used to determine the entrance/development lengths for the curved pipe flows, which are shown to scale linearly with the Reynolds number.

  10. J-R Fracture Resistance of SA533 Gr.B-Cl.1 Steel for Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji-Hyun; Hong, Seokmin; Lee, Bong-Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    A rolled plate might show different mechanical behaviors from a forging, even though they contain same chemical compositions. Furthermore, it is known that the fracture behavior of a rolled plate is very sensitive to material orientation comparing to a forging. In this study, the J-R fracture resistances of SA533 Gr.B-Cl.1 plate were measured at reactor operating temperature and the material orientation sensitivity was discussed. The decrease of fracture resistance of this kind of low alloy steel at an elevated temperature is known as the effect of dynamic strain aging (DSA). It was attributed to that the carbides and grains elongated to primary rolling direction, so that the aspect ratio of carbides and grains in the specimen with T-L orientation is larger. Generally, the hard second phase could take a roll of trigger point of unstable fracture. It is needed that the fracture surfaces of the tested specimens to be examined profoundly.

  11. 34 CFR 106.59 - Advertising.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Advertising. 106.59 Section 106.59 Education Regulations of the Offices of the Department of Education OFFICE FOR CIVIL RIGHTS, DEPARTMENT OF EDUCATION... Advertising. A recipient shall not in any advertising related to employment indicate preference, limitation...

  12. Solar heat-pipe wick modeling

    Energy Technology Data Exchange (ETDEWEB)

    Andraka, C.E.

    1999-07-01

    Stirling-cycle engines have been identified as a promising technology for the conversion of concentrated solar energy into usable electrical power. In previous experimental work, the author has demonstrated that a heat pipe receiver can significantly improve system performance over a directly-illuminated heater head. The design and operating conditions of a heat pipe receiver differ significantly from typical laboratory heat pipes. New wick structures have been developed to exploit the characteristics of the solar generation system. Typically, these wick structures allow vapor generation within the wick. Conventional heat pipe models do not handle this enhancement, yet it can more than double the performance of the wick. In this study, the author developed a steady-state model of a boiling-enhanced wick for a solar heat pipe receiver. The model is used for design-point calculations and is written in FORTRAN90. Some limited comparisons have been made with actual test data.

  13. Development of new damping devices for piping

    International Nuclear Information System (INIS)

    Kobayashi, Hiroe

    1991-01-01

    An increase of the damping ratio is known to be very effective for the seismic design of a piping system. Increasing the damping ratio and reducing the seismic response of the piping system, the following three types of damping devices for piping systems are introduced: (1) visco-elastic damper, (2) elasto-plastic damper and (3) compact dynamic damper. The dynamic characteristics of these damping devices were investigated by the component test and the applicability of them to the piping system was confirmed by the vibration test using a three dimensional piping model. These damping devices are more effective than mechanical snubbers to reduce the vibration of the piping system. (author)

  14. 46 CFR 153.280 - Piping system design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Piping system design. 153.280 Section 153.280 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.280 Piping system design. (a) Each cargo piping system must meet...

  15. Determination of Secondary Encasement Pipe Design Pressure

    Energy Technology Data Exchange (ETDEWEB)

    TEDESCHI, A.R.

    2000-10-26

    This document published results of iterative calculations for maximum tank farm transfer secondary pipe (encasement) pressure upon failure of the primary pipe. The maximum pressure was calculated from a primary pipe guillotine break. Results show encasement pipeline design or testing pressures can be significantly lower than primary pipe pressure criteria.

  16. Evaluation of J-R curve testing of nuclear piping materials using the direct current potential drop technique

    International Nuclear Information System (INIS)

    Hackett, E.M.; Kirk, M.T.; Hays, R.A.

    1986-08-01

    A method is described for developing J-R curves for nuclear piping materials using the DC Potential Drop (DCPD) technique. Experimental calibration curves were developed for both three point bend and compact specimen geometries using ASTM A106 steel, a type 304 stainless steel and a high strength aluminum alloy. These curves were fit with a power law expression over the range of crack extension encountered during J-R curve tests (0.6 a/W to 0.8 a/W). The calibration curves were insensitive to both material and sidegrooving and depended solely on specimen geometry and lead attachment points. Crack initiation in J-R curve tests using DCPD was determined by a deviation from a linear region on a plot of COD vs. DCPD. The validity of this criterion for ASTM A106 steel was determined by a series of multispecimen tests that bracketed the initiation region. A statistical differential slope procedure for determination of the crack initiation point is presented and discussed. J-R curve tests were performed on ASTM A106 steel and type 304 stainless steel using both the elastic compliance and DCPD techniques to assess R-curve comparability. J-R curves determined using the two approaches were found to be in good agreement for ASTM A106 steel. The applicability of the DCPD technique to type 304 stainless steel and high rate loading of ferromagnetic materials is discussed. 15 refs., 33 figs

  17. 78 FR 64475 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2013-10-29

    ... stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (OCTG), if covered by the scope of another antidumping duty order from the same country. If not covered by such an...

  18. Educação para a saúde a grupo de obesos

    Directory of Open Access Journals (Sweden)

    Glaci de Oliveira Pinto Vargas

    1983-03-01

    Full Text Available Este trabalho foi realizado por enfermeiras que atuam a nível ambulatorial, num Programa de Adulto, no Serviço de Saúde Pública, de um hospital geral de Porto Alegre, RS. É uma contribuição original de uma pesquisa descritivo analítica, com grupos de clientes obesos, atendidos através de cursos de educação para a saúde. Pretende-se avaliar quatro aspectos sem ordem de prioridade: a interesse da clientela pela educação da saúde, em grupo; b impressão, em relação aso conteúdos desenvolvidos; c redução do peso; d mudança de algum hábito de vida.

  19. Flow induced vibrations of piping system (Vibration sources - Mechanical response of the pipes)

    International Nuclear Information System (INIS)

    Gibert, R.J.; Axisa, F.; Villard, B.

    1978-01-01

    In order to design the supports of piping system, an estimation of the vibration induced by the fluid conveyed through the pipes are generally needed. For that purpose it is necessary. To evaluate the power spectra of all the main sources generated by the flow. These sources are located at the singular points of the circuit (enlargements, bends, valves, etc. ...). To calculate the modal parameters of fluid containing pipes. This paper presents: a methodical study of the most current singularities. Inter-correlation spectra of local pressure fluctuation downstream from the singularity and correlation spectra of associated acoustical sources have been measured. A theory of noise generation by unsteady flow in internal acoustics has been developed. All these results are very useful for evaluating the source characteristics in most practical pipes. A comparison between the calculation and the results of an experimental test has shown a good agreement

  20. Modelling of fiberglass pipe destruction process

    Directory of Open Access Journals (Sweden)

    А. К. Николаев

    2017-03-01

    Full Text Available The article deals with important current issue of oil and gas industry of using tubes made of high-strength composite corrosion resistant materials. In order to improve operational safety of industrial pipes it is feasible to use composite fiberglass tubes. More than half of the accidents at oil and gas sites happen at oil gathering systems due to high corrosiveness of pumped fluid. To reduce number of accidents and improve environmental protection we need to solve the issue of industrial pipes durability. This problem could be solved by using composite materials from fiberglass, which have required physical and mechanical properties for oil pipes. The durability and strength can be monitored by a fiberglass winding method, number of layers in composite material and high corrosion-resistance properties of fiberglass. Usage of high-strength composite materials in oil production is economically feasible; fiberglass pipes production is cheaper than steel pipes. Fiberglass has small volume weight, which simplifies pipe transportation and installation. In order to identify the efficiency of using high-strength composite materials at oil production sites we conducted a research of their physical-mechanical properties and modelled fiber pipe destruction process.

  1. 46 CFR 58.30-15 - Pipe, tubing, valves, fittings, pumps, and motors.

    Science.gov (United States)

    2010-10-01

    ... hydraulic and pneumatic systems listed in § 58.30-1. (b) Materials used in the manufacture of tubing, pipes... 6, the wall thickness may be established on the basis of an applicable thick-wall cylinder equation...

  2. Proportioning equipment for vibration filling and compacting of grain materials in pipe containers, especially of fuel elements

    International Nuclear Information System (INIS)

    Pinkas, V.; Filip, Z.; Beranek, J.

    1981-01-01

    The equipment consists of a base plate to which are attached the fastening collar fo the pipe container and the guide column with the height-adjustable support. The filling pipe is fixed to the support. The proportioning equipment prevents particles of grain material from segregation, thus allowing to achieve homogeneity of the material in the whole volume to be compacted. It also allows determining the height of the column of material in the pipe container without destructive effects on the stacked material. The equipment is designed for the manufacture of shortened fuel elements. (J.B.)

  3. Archives: Water SA

    African Journals Online (AJOL)

    Items 1 - 50 of 71 ... Archives: Water SA. Journal Home > Archives: Water SA. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 71 Items, 1 2 > >>. 2018. Vol 44, No 1 (2018) ...

  4. 34 CFR 106.53 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Recruitment. 106.53 Section 106.53 Education... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  5. 13 CFR 106.101 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... legal consideration. (i) Non-Fee Based SBA-Sponsored Activity Record (Non-Fee Based Record) means a... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Definitions. 106.101 Section 106.101 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION COSPONSORSHIPS, FEE AND NON-FEE BASED...

  6. Resolution of thermal striping issue downstream of a horizontal pipe elbow in stratified pipe flow. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kuzay, T.M.; Kasza, K.E.

    1985-01-01

    A thermally stratified pipe flow produced by a thermal transient when passing through a horizontal elbow as a result of secondary flow gives rise to large thermal fluctuations on the inner curvature wall of the downstream piping. These fluctuations were measured in a specially instrumented horizontal pipe and elbow system on a test set-up using water in the Mixing Components Technology Facility (MCTF) at Argonne National Laboratory (ANL). This study is part of a larger program which is studying the influence of thermal buoyancy on general reactor component performance. This paper discusses the influence of pipe flow generated thermal oscillations on the thermal stresses induced in the pipe walls. The instrumentation was concentrated around the exit plane of the 90/sup 0/ sweep elbow, since prior tests had indicated that the largest thermal fluctuations would occur within about one hydraulic diameter downstream of the elbow exit. The thermocouples were located along the inner curvature of the piping and measured the near surface fluid temperature. The test matrix involved thermal downramps under turbulent flow conditions.

  7. Associação entre resiliência e qualidade de vida relacionada à saúde bucal em idosos

    Directory of Open Access Journals (Sweden)

    Maurício Fernando Nunes Teixeira

    2015-03-01

    Full Text Available OBJETIVO: Avaliar a associação entre resiliência e qualidade de vida relacionada à saúde bucal, por meio de uma abordagem hierárquica baseada em um modelo teórico conceitual em uma coorte de idosos do Rio Grande do Sul. MÉTODOS: Foi conduzido um estudo transversal aninhado a um estudo de coorte, em 2008. Foram avaliados 498 idosos de Carlos Barbosa, Rio Grande do Sul. As medidas avaliadas foram sociodemográficas, comportamentos de saúde, qualidade de vida relacionada à saúde bucal, medida pelo Oral Health Impact Profile (OHIP-14, Escala de Resiliência e CPOD. A associação entre o potencial de resiliência e os impactos na percepção de saúde bucal relacionados à qualidade de vida foi verificada por meio de regressão binomial negativa. Razões das médias (RM são apresentadas com seus intervalos de confiança de 95% (IC95%. RESULTADOS: Maiores médias do OHIP foram encontradas entre mulheres (6,7 ± 6,3; p = 0,011, moradores da zona rural (7,3 ± 6,7; p = 0,004 e solteiros (8,0 ± 6,3; p = 0,032. O modelo final da análise multivariada mostrou que ser morador da zona rural (RM = 1,32; IC95% 1,06 - 1,65 e casado (RM = 1,36; IC95% 1,07 - 1,72 foram variáveis independentemente associadas à qualidade de vida relacionada à saúde bucal. Não houve associação entre resiliência e qualidade de vida relacionada à saúde bucal. CONCLUSÃO: Os resultados sugerem que variáveis sociodemográficas estão associados à qualidade de vida relacionada à saúde bucal. A hipótese de que a resiliência pudesse exercer um papel importante no desfecho não foi confirmada.

  8. 78 FR 62614 - Guttman Energy, Inc., PBF Holding Company LLC v. Buckeye Pipe Line Company, L.P., Laurel Pipe...

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR14-4-000] Guttman Energy, Inc., PBF Holding Company LLC v. Buckeye Pipe Line Company, L.P., Laurel Pipe Line Company, L.P... complaint against Buckeye Pipe Line Company L.P. and Laurel Pipe Line Company L.P. (Respondents) challenging...

  9. Representações sociais da educação em saúde pelos profissionais da equipe de saúde da família

    Directory of Open Access Journals (Sweden)

    Maria Flávia Carvalho Gazzinelli

    Full Text Available Este estudo discute a forma como os profissionais da equipe de saúde da família pensam e representam a educação em saúde e a prática educativa que realizam. Os sujeitos da pesquisa (n=248 - médico, enfermeiro, auxiliar de enfermagem e agente comunitário de saúde de 20 unidades básicas de saúde de Belo Horizonte - foram entrevistados mediante a utilização da técnica de evocação livre e da teoria das representações sociais. Solicitou-se aos sujeitos que verbalizassem cinco palavras que lhes ocorressem imediatamente em relação à educação em saúde, classificando-as em positiva ou negativa. Utilizou-se o software Evoc e calculou-se a frequência simples de ocorrência, a média ponderada de ocorrência em função da ordem de evocação e a média das ordens ponderadas do conjunto dos termos evocados. Construiu-se o quadro de quatro casas composto do núcleo central, elementos de contraste e periféricos da representação. Médicos e enfermeiros compartilham conteúdos representacionais entre si, expressando representações sociais similares, ao apresentarem nos possíveis núcleos centrais 'capacitação' e 'prevenção'. Auxiliares de enfermagem e agentes comunitários de saúde se assemelham por meio dos possíveis elementos centrais 'educação' e 'prevenção'. O foco recai na transmissão de orientações com o objetivo de persuadir os indivíduos à adoção de modos de vida saudáveis.

  10. Hot cracking of welded joints of the 7CrMoVTiB 10-10 (T/P24) steel

    Energy Technology Data Exchange (ETDEWEB)

    Adamiec, J, E-mail: janusz.adamiec@polsl.pl [Department of Materials Science, Silesian University of Technology, Krasinskiego 8, 40-019 Katowice (Poland)

    2011-05-15

    Bainitic steel 7CrMoVTiB10-10 is one the newest steels for waterwalls of modern industrial boilers. In Europe, attempts have been made to make butt welded joints of pipes made of this steel of the diameter up to 51 mm and thickness up to 8 mm. Many cracks have been observed in the welded joint, both during welding and transport and storage. The reasons of cracking and the prevention methods have not been investigated. No comprehensive research is carried out in Europe in order to automate the welding process of the industrial boiler elements made of modern bainitic steel, such as 7CrMoVTiB10-10. There is no information about its overall, operative and local weldability, influence of heat treatment, as well as about resistance of the joints to cracking during welding and use. The paper presents experience of Energoinstal SA from development of technology and production of waterwalls of boilers made of the 7CrMoVTiB 10-10 steel on a multi-head automatic welder for submerged arc welding.

  11. Quasars in the field of SA94. III. A colour survey

    International Nuclear Information System (INIS)

    Cristiani, S.; Barbieri, C.; La Franca, F.; Nota, A.

    1989-01-01

    A new sample of quasars has been selected in the central 10 square degrees of SA 94. The colour-colour U - B, B - V diagram has been used to identify low-redshift quasar candidates down to B = 19.8.99 extragalactic emission-line objects have been spectroscopically confirmed. The quasar surface density for QSOs with z ≤ 2.25 and other properties of this sample are derived and compared with other surveys

  12. 42 CFR 66.106 - Awards.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Awards. 66.106 Section 66.106 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL... program leading to the degrees of doctor of medicine and doctor of philosophy. [48 FR 24880, June 3, 1983...

  13. Experimental Investigation on Corrosion of Cast Iron Pipes

    Directory of Open Access Journals (Sweden)

    H. Mohebbi

    2011-01-01

    Full Text Available It is well known that corrosion is the predominant mechanism for the deterioration of cast iron pipes, leading to the reduction of pipe capacity and ultimate collapse of the pipes. In order to assess the remaining service life of corroded cast iron pipes, it is imperative to understand the mechanisms of corrosion over a long term and to develop models for pipe deterioration. Although many studies have been carried out to determine the corrosion behavior of cast iron, little research has been undertaken to understand how cast iron pipes behave over a longer time scale than hours, days, or weeks. The present paper intends to fill the gap regarding the long-term corrosion behaviour of cast iron pipes in the absence of historical data. In this paper, a comprehensive experimental program is presented in which the corrosion behaviour of three exservice pipes was thoroughly examined in three simulated service environments. It has been found in the paper that localised corrosion is the primary form of corrosion of cast iron water pipes. It has also been found that the microstructure of cast irons is a key factor that affects the corrosion behaviour of cast iron pipes. The paper concludes that long-term tests on corrosion behaviour of cast iron pipes can help develop models for corrosion-induced deterioration of the pipes for use in predicting the remaining service life of the pipes.

  14. Small-bore-piping seismic-test findings

    International Nuclear Information System (INIS)

    Severud, L.K.; Barta, D.A.; Anderson, M.J.

    1981-12-01

    Description is given of a test series in which a 1-inch diameter stainless steel pipe system was subjected to dynamic testing. The test system consisted of approximately 40-feet of schedule 40 pipe, with several bends and risers, supported from a rigid test frame. FFTF prototypic pipe clamps, dead weight supports, mechanical snubbers, and insulation were utilized. Several variations of the pipe support configuration were tested. Measured test results are compared with analytical predictions for each configuration. Plans for future testing are discussed

  15. Pipe supports and anchors - LMFBR applications

    International Nuclear Information System (INIS)

    Anderson, M.J.

    1983-06-01

    Pipe design and support design can not be treated as separate disciplines. A coordinated design approach is required if LMFBR pipe system adequacy is to be achieved at a reasonable cost. It is particularly important that system designers understand and consider those factors which influence support train flexibility and thus the pipe system dynamic stress levels. The system approach must not stop with the design phase but should continue thru the erection and acceptance test procedures. The factors that should be considered in the design of LMFBR pipe supports and anchors are described. The various pipe support train elements are described together with guidance on analysis, design and application aspects. Post erection acceptance and verification test procedures are then discussed

  16. SaOS-2 cell response to macro-porous boron-incorporated TiO{sub 2} coating prepared by micro-arc oxidation on titanium

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qianli [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Elkhooly, Tarek A. [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Department of Ceramics, Inorganic Chemical Industries Division, National Research Centre, Dokki, 12622 Cairo (Egypt); Liu, Xujie [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Zhang, Ranran; Yang, Xing; Shen, Zhijian [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Feng, Qingling, E-mail: biomater@mail.tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Key Laboratory of Advanced Materials of Ministry of Education of China, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2016-10-01

    The aims of the present study were to develop boron-incorporated TiO{sub 2} coating (B-TiO{sub 2} coating) through micro-arc oxidation (MAO) and subsequently evaluate the effect of boron incorporation on the in vitro biological performance of the coatings. The physicochemical properties of B-TiO{sub 2} coating and its response to osteoblast like cells (SaOS-2) were investigated compared to the control group without boron (TiO{sub 2} coating). The morphological and X-ray diffraction results showed that both coatings exhibited similar surface topography and phase composition, respectively. However, the incorporation of B led to an enhancement in the surface hydrophilicity of B-TiO{sub 2} coating. The spreading of SaOS-2 cells on B-TiO{sub 2} coating was faster than that on TiO{sub 2} coating. The proliferation rate of SaOS-2 cells cultured on B-TiO{sub 2} decreased after 5 days of culture compared to that on TiO{sub 2} coating. SaOS-2 cells cultured on B-TiO{sub 2} coating exhibited an enhanced alkaline phosphatase (ALP) activity, Collagen I synthesis and in vitro mineralization compared to those on TiO{sub 2} coating. The present findings suggest that B-TiO{sub 2} coating is a promising candidate surface for orthopedic implants. - Highlights: • SaOS-2 cell response to pure TiO{sub 2} and B-TiO{sub 2} coatings was investigated. • Initial cell spreading on B-TiO{sub 2} coating was accelerated compared to that on TiO{sub 2} coating. • Cell proliferation on B-TiO{sub 2} coating was inhibited compared to that on TiO{sub 2} coating. • Cell differentiation on B-TiO{sub 2} coating was enhanced compared to that on TiO{sub 2} coating.

  17. Structural integrity assessment of piping components

    International Nuclear Information System (INIS)

    Kushwaha, H.S.; Chattopadhyay, J.

    2008-01-01

    Integrity assessment of piping components is very essential for safe and reliable operation of power plants. Over the last several decades, considerable work has been done throughout the world to develop a methodology for integrity assessment of pipes and elbows, appropriate for the material involved. However, there is scope of further development/improvement of issues, particularly for pipe bends, that are important for accurate integrity assessment of piping. Considering this aspect, a comprehensive Component Integrity Test Program was initiated in 1998 at Bhabha Atomic Research Centre (BARC), India. In this program, both theoretical and experimental investigations were undertaken to address various issues related to the integrity assessment of pipes and elbows. Under the experimental investigations, fracture mechanics tests have been conducted on pipes and elbows of 200-400 mm nominal bore (NB) diameter with various crack configurations and sizes under different loading conditions. Tests on small tensile and three point bend specimens, machined from the tested pipes, have also been done to evaluate the actual stress-strain and fracture resistance properties of pipe/elbow material. The load-deflection curve and crack initiation loads predicted by non-linear finite element analysis matched well with the experimental results. The theoretical collapse moments of throughwall circumferentially cracked elbows, predicted by the recently developed equations, are found to be closer to the test data compared to the other existing equations. The role of stress triaxialities ahead of crack tip is also shown in the transferability of J-Resistance curve from specimen to component. The cyclic loading and system compliance effect on the load carrying capacity of piping components are investigated and new recommendations are made. (author)

  18. Analysis of pipe stress using CAESAR II code

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    Analysis of this piping stress with the purpose of knowing stress distribution piping system in order to determine pipe supports configuration. As an example of analysis, Gas Exchanger to Warm Separator Line was chosen with, input data was firstly prepared in a document, i.e. piping analysis specification that its content named as pipe characteristics, material properties, operation conditions, guide equipment's and so on. Analysis result such as stress, load, displacement and the use support type were verified based on requirements in the code, standard, and regularities were suitable with piping system condition analyzed. As the proof that piping system is in safety condition, it can be indicated from analysis results (actual loads) which still under allowable load. From the analysis steps that have been done CAESAR II code fulfill requirements to be used as a tool of piping stress analysis as well as nuclear and non nuclear installation piping system

  19. Reporte financiero Burkenroad - Enka de Colombia S.A.

    OpenAIRE

    Jaramillo Estrada, Adriana; Tobón Flórez, Wilmer Andrés

    2015-01-01

    La recomendación de comprar la acción de Enka de Colombia S.A. se fundamenta en una estrategia sólida que busca un equilibrio entre la sostenibilidad, el impacto social, ambiental y ético, y la eficiencia en costos -- Adicionalmente, su diversificación del portafolio incursionando en proyectos como el denominado B2B (Botella-a-Botella) en el que se construyó la planta de reciclaje de PET que convierte a Enka en el líder de reciclaje PET en Colombia -- Otro proyecto que ha entrado en funcio...

  20. Investigation on field method using strain measurement on pipe surface to measure pressure pulsation in piping systems

    International Nuclear Information System (INIS)

    Maekawa, Akira; Tsuji, Takashi; Takahashi, Tsuneo; Kato, Minoru

    2013-01-01

    Accurate evaluation of the occurrence location and amplitude of pressure pulsations in piping systems can lead to efficient plant maintenance by preventing fatigue failure of piping and components because the pulsations can be one of the main causes of vibration fatigue and acoustic noise in piping. A non-destructive field method to measure pressure pulsations easily and directly was proposed to replace conventional methods such as prediction using numerical simulations and estimation using locally installed pressure gauges. The proposed method was validated experimentally by measuring pulsating flow in a mock-up piping system. As a result, it was demonstrated that the method to combine strain measurement on the outer surface of pipe with the formula for thick-walled cylinders could measure amplitudes and behavior of the pressure pulsations with a practical accuracy. Factors affecting the measurement accuracy of the proposed method were also discussed. Furthermore, the applicability of the formula for thin-walled cylinders was examined for variously shaped pipes. (author)

  1. Innovative technology summary report: Pipe Explorertrademark system

    International Nuclear Information System (INIS)

    1996-01-01

    The Pipe Explorertrademark system, developed by Science and Engineering Associates, Inc. (SEA), under contract with the US Department of Energy (DOE) Morgantown Energy Technology Center, has been used to transport various characterizing sensors into piping systems that have been radiologically contaminated. DOE's nuclear facility decommissioning program must characterize radiological contamination inside piping systems before the pipe can be recycled, remediated, or disposed. Historically, this has been attempted using hand-held survey instrumentation, surveying only the accessible exterior portions of pipe systems. Various measuring difficulties, and in some cases, the inability to measure threshold surface contamination values and worker exposure, and physical access constraints have limited the effectiveness of traditional survey approaches. The Pipe Explorertrademark system provides a viable alternative. The heart of the system is an air-tight membrane, which is initially spooled inside a canister. The end of the membrane protrudes out of the canister and attaches to the pipe being inspected. The other end of the tubular membrane is attached to the tether and characterization tools. When the canister is pressurized, the membrane inverts and deploys inside the pipe. The characterization detector and its cabling is attached to the tethered end of the membrane. As the membrane is deployed into the pipe, the detector and its cabling is towed into the pipe inside the protective membrane; measurements are taken from within the protective membrane. Once the survey measurements are completed, the process is reversed to retrieve the characterization tools

  2. Cultura organizacional na área da saúde: um estudo bibliométrico

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Fonseca

    Full Text Available RESUMO O artigo objetivou identificar as características das pesquisas na área de saúde sobre o tema cultura organizacional publicadas em revistas brasileiras. A busca foi efetuada na Biblioteca Virtual em Saúde a partir do termo ‘cultura organizacional’, no período de 2007 a 2016. Foram encontrados 30 artigos em revistas nacionais de Qualis A1, A2, B1 nas áreas de avaliação Capes (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior: enfermagem, saúde coletiva e psicologia. Os resultados evidenciaram o predomínio de artigos quantitativos e a aplicação de grande variedade de instrumentos para analisar a cultura organizacional na saúde, o que amplia as possibilidades de investigação e análise de diferentes aspectos do tema.

  3. 49 CFR 236.712 - Brake pipe.

    Science.gov (United States)

    2010-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.712 Brake pipe. A pipe running from the engineman's brake valve through the train, used for the transmission of air under... 49 Transportation 4 2010-10-01 2010-10-01 false Brake pipe. 236.712 Section 236.712 Transportation...

  4. Characterization of radioactive contamination inside pipes with the Pipe Explorer trademark system

    International Nuclear Information System (INIS)

    Lowry, W.

    1994-01-01

    The objective for the development of the Pipe Explorer trademark radiological characterization system is to achieve a cost effective, low risk means of characterizing gamma radioactivity on the inside surface of pipes. The unique feature of this inspection system is the use of a pneumatically inflated impermeable membrane which transports the detector into the pipe as it inverts. The membrane's internal air pressure tows the detector and tether through the pipe. This mechanism isolates the detector and its cabling from the contaminated surface, yet allows measurement of radioactive emissions which can readily penetrate the thin plastic membrane material (such as gamma and high energy beta emissions). In Phase 1, an initial survey of DOE facilities was conducted to determine the physical and radiological characteristics of piping systems. The inverting membrane deployment system was designed and extensively tested in the laboratory. A range of membrane materials was tested to evaluate their ruggedness and deployment characteristics. Two different sizes of gamma scintillation detectors were procured and tested with calibrated sources. Radiation transport modeling evaluated the measurement system's sensitivity to detector position relative to the contaminated surface, the distribution of the contamination, background gamma levels, and gamma source energy levels. In the culmination of Phase 1, a field demonstration was conducted at the Idaho National Engineering Laboratory's Idaho Chemical Processing Plant. The project is currently in transition from Phase 1 to Phase 2, where more extensive demonstrations will occur at several sites. Results to date are discussed

  5. Stuck pipe prediction

    KAUST Repository

    Alzahrani, Majed; Alsolami, Fawaz; Chikalov, Igor; Algharbi, Salem; Aboudi, Faisal; Khudiri, Musab

    2016-01-01

    Disclosed are various embodiments for a prediction application to predict a stuck pipe. A linear regression model is generated from hook load readings at corresponding bit depths. A current hook load reading at a current bit depth is compared with a normal hook load reading from the linear regression model. A current hook load greater than a normal hook load for a given bit depth indicates the likelihood of a stuck pipe.

  6. Stuck pipe prediction

    KAUST Repository

    Alzahrani, Majed

    2016-03-10

    Disclosed are various embodiments for a prediction application to predict a stuck pipe. A linear regression model is generated from hook load readings at corresponding bit depths. A current hook load reading at a current bit depth is compared with a normal hook load reading from the linear regression model. A current hook load greater than a normal hook load for a given bit depth indicates the likelihood of a stuck pipe.

  7. Casing free district heating pipes; Mantelfria fjaerrvaermeroer

    Energy Technology Data Exchange (ETDEWEB)

    Saellberg, Sven-Erik; Nilsson, Stefan [Swedish National Testing and Research Inst., Goeteborg (Sweden)

    2005-07-01

    Previous studies have shown that polyurethane insulation (PUR foam) on district heating pipes acts as protection against water if it is of good quality, i.e. free from cracks, cavities and other defects. On the other hand water vapour easily diffuses through PUR foam. However this is not a problem as long as the steel pipe is warmer than the surface layer, since the high temperature will prevent the vapour from condensating. What will happen with the insulation of a casing free district heating pipe where the ground water level occasionally reaches above the pipe has not been studied in detail. The current project has studied to what extent moisture enters the PUR foam insulation of two approximately one meter long district heating pipes without casing which have been in the ground for four years. Occasionally, the ground-water has entirely covered the pipes. In addition, the foam has been studied with respect to damage from the surrounding backfill material. Test specimens were taken out of the casing free pipes and were analysed with respect to moisture content. Additional measurements were done with a moisture indicator, and the electric resistance between the steel pipes and the four surveillance wires in each pipe was measured. The results from the various measurement techniques were the compared. The results show that the PUR foam remains dry as long as the service pipe is hot if no defects, such as crack and cavities, are present. Close to the service pipe, the foam actually dries out over time. The moisture content of the middle layer remains more or less constant. Only the colder parts on the outside exhibit an increase in moisture content. It was also seen that defects may lead to water ingress with subsequent humidification of the foam. However, the damaged foam area is limited. This is not the case for a regular pipe with a vapour tight casing, where experience show that moisture tend to spread along the pipe. The pipes were buried in sand and no

  8. Earthquake free design of pipe lines

    International Nuclear Information System (INIS)

    Kurihara, Chizuko; Sakurai, Akio

    1974-01-01

    Long structures such as cooling sea water pipe lines of nuclear power plants have a wide range of extent along the ground surface, and are incurred by not only the inertia forces but also forces due to ground deformations or the seismic wave propagation during earthquakes. Since previous reports indicated the earthquake free design of underground pipe lines, it is discussed in this report on behaviors of pipe lines on the ground during earthquakes and is proposed the aseismic design of pipe lines considering the effects of both inertia forces and ground deformations. (author)

  9. Performance of wickless heat pipe flat plate solar collectors having different pipes cross sections geometries and filling ratios

    International Nuclear Information System (INIS)

    Hussein, H.M.S.; El-Ghetany, H.H.; Nada, S.A.

    2006-01-01

    In the present study, the effect of wickless heat pipe cross section geometry and its working fluid filling ratio on the performance of flat plate solar collectors has been investigated experimentally. Three groups of wickless heat pipes having three different cross section geometries (namely, circular, elliptical and semi-circular cross sections) were designed and manufactured. Each group of three wickless heat pipes was charged with three different distilled water filling ratios of 10%, 20% and 35%. Each wickless heat pipe was then incorporated into a prototype flat plate solar collector developed for the purpose of the present study. The prototypes wickless heat pipe flat plate solar collectors have been investigated experimentally at different inlet cooling water temperatures, two different cooling water mass flow rates and under the meteorological conditions of Cairo, Egypt. The experimental results indicate that the elliptical cross section wickless heat pipe flat plate solar collectors have better performance than the circular cross section ones at low water filling ratios. The optimum water filling ratio of the elliptical cross section wickless heat pipe solar collector is about 10%, while it is very close to 20% for the circular cross section one. Also, the water filling ratio corresponding to the flooding limit of the elliptical wickless heat pipe solar collector is lower than that of the circular one. At 20% water filling ratio, the semi-circular cross section wickless heat pipe solar collector has bad performance compared with that of the other cross sections

  10. Pipe support optimization in nuclear power plants

    International Nuclear Information System (INIS)

    Cleveland, A.B.; Kalyanam, N.

    1984-01-01

    A typical 1000 MWe nuclear power plant consists of 80,000 to 100,000 feet of piping which must be designed to withstand earthquake shock. For the required ground motion, seismic response spectra are developed for safety-related structures. These curves are used in the dynamic analysis of piping systems with pipe-stress analysis computer codes. To satisfy applicable Code requirements, the piping systems also require analysis for weight, thermal and possibly other lasting conditions. Bechtel Power Corporation has developed a design program called SLAM (Support Location Algorithm) for optimizing pipe support locations and types (rigid, spring, snubber, axial, lateral, etc.) while satisfying userspecified parameters such as locations, load combinations, stress and load allowables, pipe displacement and cost. This paper describes SLAM, its features, applications and benefits

  11. 49 CFR 195.424 - Pipe movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipe movement. 195.424 Section 195.424... PIPELINE Operation and Maintenance § 195.424 Pipe movement. (a) No operator may move any line pipe, unless... in the line section involved are joined by welding unless— (1) Movement when the pipeline does not...

  12. Nuclear class 1 piping stress analysis

    International Nuclear Information System (INIS)

    Lucas, J.C.R.; Maneschy, J.E.; Mariano, L.A.; Tamura, M.

    1981-01-01

    A nuclear class 1 piping stress analysis, according to the ASME code, is presented. The TRHEAT computer code has been used to determine the piping wall thermal gradient. The Nupipe computer code was employed for the piping stress analysis. Computer results were compared with the allowable criteria from the ASME code. (Author) [pt

  13. Application of LBB to a nozzle-pipe interface

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y.J.; Sohn, G.H.; Kim, Y.J. [and others

    1997-04-01

    Typical LBB (Leak-Before-Break) analysis is performed for the highest stress location for each different type of material in the high energy pipe line. In most cases, the highest stress occurs at the nozzle and pipe interface location at the terminal end. The standard finite element analysis approach to calculate J-Integral values at the crack tip utilizes symmetry conditions when modeling near the nozzle as well as away from the nozzle region to minimize the model size and simplify the calculation of J-integral values at the crack tip. A factor of two is typically applied to the J-integral value to account for symmetric conditions. This simplified analysis can lead to conservative results especially for small diameter pipes where the asymmetry of the nozzle-pipe interface is ignored. The stiffness of the residual piping system and non-symmetries of geometry along with different material for the nozzle, safe end and pipe are usually omitted in current LBB methodology. In this paper, the effects of non-symmetries due to geometry and material at the pipe-nozzle interface are presented. Various LBB analyses are performed for a small diameter piping system to evaluate the effect a nozzle has on the J-integral calculation, crack opening area and crack stability. In addition, material differences between the nozzle and pipe are evaluated. Comparison is made between a pipe model and a nozzle-pipe interface model, and a LBB PED (Piping Evaluation Diagram) curve is developed to summarize the results for use by piping designers.

  14. Vigilância de óbitos infantis em sistemas locais de saúde: avaliação da autópsia verbal e das informações de agentes de saúde

    Directory of Open Access Journals (Sweden)

    Barrêto Ivana C. H. C.

    2000-01-01

    Full Text Available Conhecer os eventos vitais de uma população é de fundamental importância para combater a morbimortalidade e melhorar as condições de vida. Contudo, no Brasil, os sistemas de informação de saúde têm-se mostrado ineficientes. No presente estudo, realizado em três municípios do Estado do Ceará (Quixadá, Icapuí e Jucás, com boa cobertura de serviços de atenção primária à saúde, foram investigados, através de um instrumento epidemiológico denominado autópsia verbal, 215 óbitos de crianças menores de 1 ano de idade, representando 90% do total dos óbitos em 1993 e 1994. Foram averiguadas as características socioeconômicas, cuidados e higiene, estado nutricional, o processo de doença, assistência e morte, a causa básica do óbito e o funcionamento do sistema de informação sobre mortalidade e do sistema de informação de agentes de saúde. Segundo a autópsia verbal, 39% dos óbitos tiveram como causa básica a diarréia, seguida da prematuridade (17% e infecção respiratória aguda (10%; 49% das crianças morreram no domicílio, embora 79% das famílias tenham procurado os serviços de saúde no decorrer da doença fatal, sugerindo uma baixa efetividade na identificação e no tratamento de lactentes com doenças graves. Em 84% dos casos, a família procurou a rezadeira. Os agentes de saúde foram procurados em 29% dos casos, embora tenham notificado 78% dos óbitos investigados. A concordância estatística entre diagnóstico dos agentes de saúde para a causa básica do óbito e autópsia verbal foi boa para a diarréia, regular para outras causas, e fraca para a infecção respiratória aguda. A incorporação da autópsia verbal à rotina dos serviços de atenção primária à saúde do Estado propiciaria informações valiosas para as equipes locais de saúde e geraria uma consciência crítica que favorece a redução da mortalidade infantil.

  15. Vigilância de óbitos infantis em sistemas locais de saúde: avaliação da autópsia verbal e das informações de agentes de saúde

    Directory of Open Access Journals (Sweden)

    Ivana C. H. C. Barrêto

    2000-05-01

    Full Text Available Conhecer os eventos vitais de uma população é de fundamental importância para combater a morbimortalidade e melhorar as condições de vida. Contudo, no Brasil, os sistemas de informação de saúde têm-se mostrado ineficientes. No presente estudo, realizado em três municípios do Estado do Ceará (Quixadá, Icapuí e Jucás, com boa cobertura de serviços de atenção primária à saúde, foram investigados, através de um instrumento epidemiológico denominado autópsia verbal, 215 óbitos de crianças menores de 1 ano de idade, representando 90% do total dos óbitos em 1993 e 1994. Foram averiguadas as características socioeconômicas, cuidados e higiene, estado nutricional, o processo de doença, assistência e morte, a causa básica do óbito e o funcionamento do sistema de informação sobre mortalidade e do sistema de informação de agentes de saúde. Segundo a autópsia verbal, 39% dos óbitos tiveram como causa básica a diarréia, seguida da prematuridade (17% e infecção respiratória aguda (10%; 49% das crianças morreram no domicílio, embora 79% das famílias tenham procurado os serviços de saúde no decorrer da doença fatal, sugerindo uma baixa efetividade na identificação e no tratamento de lactentes com doenças graves. Em 84% dos casos, a família procurou a rezadeira. Os agentes de saúde foram procurados em 29% dos casos, embora tenham notificado 78% dos óbitos investigados. A concordância estatística entre diagnóstico dos agentes de saúde para a causa básica do óbito e autópsia verbal foi boa para a diarréia, regular para outras causas, e fraca para a infecção respiratória aguda. A incorporação da autópsia verbal à rotina dos serviços de atenção primária à saúde do Estado propiciaria informações valiosas para as equipes locais de saúde e geraria uma consciência crítica que favorece a redução da mortalidade infantil.

  16. Flow induced vibrations of piping

    International Nuclear Information System (INIS)

    Gibert, R.J.; Axisa, F.

    1977-01-01

    In order to design the supports of piping systems, estimations of the vibrations induced by the fluid conveyed through the pipes are generally needed. For that purpose it is necessary to calculate the model parameters of liquid containing pipes. In most computer codes, fluid effects are accounted for just by adding the fuid mass to the structure. This may lead to serious errors.- Inertial effects from the fluid are not correctly evaluated especially in the case of bended or of non-uniform section pipes. Fluid boundary conditions are simply ignored. - In many practical problems fluid compressibility cannot be negelcted, even in the low frequencies domain which corresponds to efficient excitation by turbulent sources of the flow. This paper presents a method to take into account these efects, by solving a coupled mechanical acoustical problem: the computer code TEDEL of the C.E.A./D.E.M.T. System, based on the finite-elements method, has been extended to calculate simultaneously the pressure fluctuations in the fluid and the vibrations of the pipe. (Auth.)

  17. Pipe crawler with extendable legs

    International Nuclear Information System (INIS)

    Zollinger, W.T.

    1992-01-01

    A pipe crawler for moving through a pipe in inchworm fashion having front and rear leg assemblies separated by air cylinders to increase and decrease the spacing between assemblies. Each leg of the four legs of an assembly is moved between a wall-engaging, extended position and a retracted position by a separate air cylinder. The air cylinders of the leg assemblies are preferably arranged in pairs of oppositely directed cylinders with no pair lying in the same axial plane as another pair. Therefore, the cylinders can be as long as a leg assembly is wide and the crawler can crawl through sections of pipes where the diameter is twice that of other sections. The crawler carries a valving system, a manifold to distribute air supplied by a single umbilical air hose to the various air cylinders in a sequence controlled electrically by a controller. The crawler also utilizes a rolling mechanism, casters in this case, to reduce friction between the crawler and pipe wall thereby further extending the range of the pipe crawler. 8 figs

  18. Pipe crawler with extendable legs

    Science.gov (United States)

    Zollinger, W.T.

    1992-06-16

    A pipe crawler for moving through a pipe in inchworm fashion having front and rear leg assemblies separated by air cylinders to increase and decrease the spacing between assemblies. Each leg of the four legs of an assembly is moved between a wall-engaging, extended position and a retracted position by a separate air cylinder. The air cylinders of the leg assemblies are preferably arranged in pairs of oppositely directed cylinders with no pair lying in the same axial plane as another pair. Therefore, the cylinders can be as long as a leg assembly is wide and the crawler can crawl through sections of pipes where the diameter is twice that of other sections. The crawler carries a valving system, a manifold to distribute air supplied by a single umbilical air hose to the various air cylinders in a sequence controlled electrically by a controller. The crawler also utilizes a rolling mechanism, casters in this case, to reduce friction between the crawler and pipe wall thereby further extending the range of the pipe crawler. 8 figs.

  19. Microcomputer generated pipe support calculations

    International Nuclear Information System (INIS)

    Hankinson, R.F.; Czarnowski, P.; Roemer, R.E.

    1991-01-01

    The cost and complexity of pipe support design has been a continuing challenge to the construction and modification of commercial nuclear facilities. Typically, pipe support design or qualification projects have required large numbers of engineers centrally located with access to mainframe computer facilities. Much engineering time has been spent repetitively performing a sequence of tasks to address complex design criteria and consolidating the results of calculations into documentation packages in accordance with strict quality requirements. The continuing challenges of cost and quality, the need for support engineering services at operating plant sites, and the substantial recent advances in microcomputer systems suggested that a stand-alone microcomputer pipe support calculation generator was feasible and had become a necessity for providing cost-effective and high quality pipe support engineering services to the industry. This paper outlines the preparation for, and the development of, an integrated pipe support design/evaluation software system which maintains all computer programs in the same environment, minimizes manual performance of standard or repetitive tasks, and generates a high quality calculation which is consistent and easily followed

  20. A interdisciplinaridade vivenciada no PET-Saúde = The interdisciplinarity experienced in the PET- Saúde program

    Directory of Open Access Journals (Sweden)

    Assega, Mariana Lieka

    2010-01-01

    Full Text Available Introdução: A incorporação da equipe de saúde bucal na Estratégia de Saúde da Família (ESF, em 2000, possibilitou a adoção de uma postura mais ativa de atenção primária nesta área, visto que a saúde bucal consiste em parte integrante e inseparável da saúde do indivíduo. A interação dos profissionais da saúde torna-se possível por meio de iniciativas como o PET-Saúde, o qual fomenta a formação profissional articulada com os profissionais da ESF, bem como, o processo de integração ensino-serviço-comunidade na perspectiva da interdisciplinaridade. Objetivo: Relatar a vivência de estudantes ao realizar uma pesquisa interdisciplinar. Descrição da experiência: Esse relato foi vivenciado no projeto PET-Saúde da Faculdade de Medicina de Marília, no sub projeto Saúde do Homem, visando construir e validar um instrumento de coleta de dados por meio da Técnica Delphi, para auxiliar a equipe de saúde detectar precocemente agravos odontológicos, visto que no Brasil, o perfil de saúde bucal, na faixa etária de 35 a 44 anos, está comprometido. Os participantes, deste estudo, são discentes de enfermagem e medicina, preceptora cirurgiã-dentista e tutora docente enfermeira. Para as atividades educacionais utilizou-se a metodologia ativa de ensino-aprendizagem. Conclusão: Os movimentos reflexivos, os espaços de diálogos propiciaram o desenvolvimento da investigação científica. Além disso, a aproximação do processo de validação pela Técnica Delphi, também permitiu ampliação do conhecimento multidisciplinar sobre saúde bucal. Esta vivência possibilitou qualificar a formação acadêmico-profissional na linha da interdisciplinaridade, sendo importante sua multiplicação para o fortalecimento da interação entre os profissionais e a articulação das ações de saúde

  1. 12 CFR 622.106 - Service of subpoena and payment of witness fees.

    Science.gov (United States)

    2010-01-01

    .... (b) Motions to quash. Any person to whom a subpoena is directed may, prior to the time specified... Board, determines in his, her, or its discretion, to be just, reasonable, and proper. ... PRACTICE AND PROCEDURE Rules and Procedures Applicable to Formal Investigations § 622.106 Service of...

  2. 49 CFR 230.106 - Steam locomotive frame.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Steam locomotive frame. 230.106 Section 230.106... Tenders Trucks, Frames and Equalizing System § 230.106 Steam locomotive frame. (a) Maintenance and inspection. Frames, decks, plates, tailpieces, pedestals, and braces shall be maintained in a safe and...

  3. 18 CFR 284.103-284.106 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false [Reserved] 284.103-284.106 Section 284.103-284.106 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES Certain Transportation by Interstate Pipelines §§ 284.103-284.106 [Reserved] ...

  4. Tendências de gerenciamento de unidades de saúde e de pessoas

    Directory of Open Access Journals (Sweden)

    Adriana Maria André

    2013-02-01

    Full Text Available OBJETIVO: Identificar que fatores produzem novas tendências no gerenciamento das unidades básicas de saúde e mudanças nos modelos de gestão. MÉTODOS: Estudo prospectivo com dez gestores de unidades de saúde e dez especialistas da área de saúde de São Paulo, SP, em 2010. Foi adotada a metodologia Delphi. Foram utilizadas quatro rodadas para a coleta de dados, três quantitativas e a quarta qualitativa. Nas três primeiras foram levantadas as tendências de mudança nos modelos de gestão; no perfil do gestor e nas competências requeridas para a função, foi utilizado o teste estatístico de Mann Whitney. A quarta rodada ocorreu por meio de um painel com os envolvidos, tendo sido escolhida a análise temática. RESULTADOS: Foram identificados os principais fatores que estão impulsionando o gerenciamento das unidades básicas de saúde, como as mudanças nos modelos de gestão. Foi consenso de que as dificuldades no gerenciamento das equipes e nas políticas influemciam nesse processo. Verificou-se que os gestores estão a par das tendências do macrocontexto com o advento das organizações sociais de saúde, mas ainda não estão se antecipando nas ações institucionais. CONCLUSÕES: A formação acadêmica deve ser revista não só quanto aos conteúdos, mas quanto ao desenvolvimento desses profissionais. O recrutamento, a seleção, o desenvolvimento e a avaliação devem ser norteados por essas competências alinhadas à missão, à visão, aos valores e aos modelos de gestão das organizações no contexto do Sistema Único de Saúde.

  5. The IPIRG-1 pipe system fracture tests: Experimental results

    International Nuclear Information System (INIS)

    Scott, P.; Olson, R.J.; Wilkowski, G.M.

    1994-01-01

    As part of the First International Piping Integrity Research Group (IPIRG-1) program, six dynamic pipe system experiments were conducted. The objective of these experiments was to generate experimental data to assess analysis methodologies for characterizing the fracture behavior of circumferentially cracked pipe in a representative piping system subjected to combined inertial and displacement-controlled stresses. A unique experimental facility was designed and constructed. The pipe system evaluated was an expansion loop with over 30 m (100 feet) of 16-inch nominal diameter Schedule 100 pipe. The experimental facility was equipped with special hardware to ensure that system boundary conditions could be appropriately modeled. The test matrix involved one uncracked and five cracked dynamic pipe system experiments. The uncracked-pipe experiment was conducted to evaluate the piping system damping and natural frequency characteristics. The cracked-pipe experiments were conducted to evaluate the fracture behavior, piping system response, and fracture stability characteristics of five different materials. All cracked-pipe experiments were conducted at PWR conditions. Material characterization efforts provided the tensile and fracture toughness properties of the different pipe materials at various strain rates and temperatures. Key results from the six pipe system experiments and material characterization efforts are presented. Detailed analyses will be published in a companion paper

  6. Trabalho em saúde: retrato dos agentes comunitários de saúde da região Nordeste do Brasil

    Directory of Open Access Journals (Sweden)

    Paloma Ribeiro Pires Simas

    Full Text Available Resumo O objetivo deste estudo consistiu em caracterizar o perfil e os aspectos relacionados à gestão do trabalho dos agentes comunitários de saúde na Região Nordeste do Brasil. Trata-se de um estudo transversal, que contemplou 535 agentes comunitários distribuídos em 107 unidades básicas de saúde da Região Nordeste do Brasil. Os dados foram extraídos de oito blocos de questões referentes à Percepção dos Agentes Comunitários de Saúde sobre aspectos: sociodemográficos, econômico e político; mecanismos de contratação e remuneração; valorização do trabalhador, condições de trabalho e processos de formação dos agentes. Os resultados apontam que a proporção de agentes comunitários contratados pela administração direta na Região Nordeste é predominante. A forma de inserção dos agentes comunitários nos serviços de saúde se deu por concurso seguido de seleção pública. A administração direta é a principal forma de contratação, no entanto, novas modalidades, como as fundações de direito público e privado, organizações sociais e consórcios intermunicipais, constituem alternativas adotadas pelos gestores, produzindo um conjunto de fragilidades provocadas pela flexibilização das relações de trabalho.

  7. [Water-pipe tobacco smoking among school children in Israel: frequencies, habits, and attitudes].

    Science.gov (United States)

    Varsano, Shabtai; Ganz, Irit; Eldor, Naomi; Garenkin, Mila

    2003-11-01

    Tobacco smoking via a water-pipe (Nargile) is a new phenomena among school children in Israel in recent years. Water-pipe tobacco has the potential for nicotine addiction, for other smoking-related damages and for drug abuse. Our primary goal was to characterize the frequencies of water-pipe smoking among school children in Israel, its distribution according to age, gender, habits and attitudes. The secondary goal was to compare its use to cigarette smoking among these school children. A self-reported questionnaire was distributed among 388 school children (ages 12-18 years old) in grades A, and C, of middle schools and grade B of high schools in a central region of Israel. The questionnaires were answered unanimously and the process was conducted in classes by the school teacher and by nursing school students. Among all school children in this study, 41% smoke a water-pipe at various frequencies. Of all the children, 22% smoke at least every weekend. Water-pipe smoking was 3 times more frequent than cigarette smoking and was almost equally distributed among both genders, but girls were heavier smokers than boys, of either water pipe or cigarette smoking. Six percent of water-pipe smokers add psychoactive drugs or alcohol to the tobacco. The main reasons for water-pipe smoking were the pleasure achieved and the intimacy that it adds to the youngsters' meetings. Ninety percent of all the school children believe that water-pipe smoking is not healthy, but at least 50% believes it is less harmful than cigarettes. According to school children that smoke water-pipes at least every weekend, 40% of their parents are current or ex-smokers of water-pipes, in contrast with 10% of parents to non-smoking children and about a quarter of the children who smoke also do so together with their parents. Tobacco smoking via water-pipes is a very common phenomena among middle and high school children in Israel. Girls are heavier smokers and adding drugs or alcohol to water-pipe

  8. Design rules for piping: Plastic stability of straight parts under level D loadings

    International Nuclear Information System (INIS)

    Touboul, F.; Ben Djidia, M.; Acker, D.

    1989-01-01

    Design rules for piping, elaborated for Fast Breeder Reactors, are based on analysis performed for Pressure Water Reactors. Interpretation of largely diversified straight parts tests, enable us to validate and improve existing rules and to propose a more suitable formula. Design rules for piping appear to be non conservative for austenitic thin tubes in bending or torsion. By introducing a B 2 coefficient, geometrically dependent, the gap between thin and thick tubes may be withheld. Conservatism of rules can be ensured by considering the allowable stress defined by ASME, Section III, Appendix F

  9. 7 CFR 4280.106 - Conflict of interest.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Conflict of interest. 4280.106 Section 4280.106... Efficiency Improvements Program § 4280.106 Conflict of interest. No conflict of interest or appearance of conflict of interest will be allowed. For purposes of this subpart, conflict of interest includes, but is...

  10. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    International Nuclear Information System (INIS)

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-01-01

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  11. Computation of the temperatures of a fluid flowing through a pipe from temperature measurements on the pipe's outer surface

    International Nuclear Information System (INIS)

    Sauer, G.

    1999-01-01

    A method for computing the temperatures of a fluid flowing through a pipe on the basis of temperatures recorded at the pipe's outer surface is presented. The heat conduction in the pipe wall is described by one-dimensional heat conduction elements. Heat transfer between fluid, pipe and surrounding is allowed for. The equation system resulting from the standard finite element discretization is reformulated to enable the computation of temperature events preceding the recorded temperature in time. It is shown that the method can be used to identify the actual fluid temperature from temperature data obtained only at the outer surface of the pipe. The temperatures in the pipe wall are computed with good accuracy even in the case of a severe thermal shock. (orig.) [de

  12. Analysis of Municipal Pipe Network Franchise Institution

    Science.gov (United States)

    Yong, Sun; Haichuan, Tian; Feng, Xu; Huixia, Zhou

    Franchise institution of municipal pipe network has some particularity due to the characteristic of itself. According to the exposition of Chinese municipal pipe network industry franchise institution, the article investigates the necessity of implementing municipal pipe network franchise institution in China, the role of government in the process and so on. And this offers support for the successful implementation of municipal pipe network franchise institution in China.

  13. Secondary pipe rupture at Mihama unit 3

    International Nuclear Information System (INIS)

    Hajime Ito; Takehiko Sera

    2005-01-01

    The secondary system pipe rupture occurred on August 9, 2004, while Mihama unit 3 was operating at the rated thermal power. The rupture took place on the condensate line-A piping between the No.4 LP heater and the deaerator, downstream of an orifice used for measuring the condensate flux. The pipe is made of carbon steel, and normally has 558.8 mm diameter and 10 mm thickness. The pipe wall had thinned to 0.4 mm at the point of minimum thickness. It is estimated that the disturbed flow of water downstream of the orifice caused erosion/corrosion and developed wall thinning, leading to a rupture at the thinnest section under internal pressure, about 1MPa. Observation of the pipe internal surface revealed a scale-like pattern typical in this kind of phenomenon. Eleven workers who were preparing for an annual outage that was to start from August 14 suffered burn injuries, of who five died. Since around 1975, we, Kansai Electric, have been checking pipe wall thickness while focusing on the thinning of carbon steel piping in the secondary system. Summarizing the results from such investigation and reviewing the latest technical knowledge including operating experience from overseas utilities, we compiled the pipe thickness management guideline for PWR secondary pipes, 1990. The pipe section that ruptured at the Mihama unit 3 should have been included within the inspection scopes according to the guideline but was not registered on the inspection list. It had not been corrected for almost thirty years. As the result, this pipe section had not been inspected even once since the beginning of the plant operation, 1976. It seems that the quality assurance and maintenance management had not functioned well regarding the secondary system piping management, although we were responsible for the safety of nuclear power plants as licensee. We will review the secondary system inspection procedure and also improve the pipe thickness management guideline. And also, we would replace

  14. Leachate storage transport tanker loadout piping

    International Nuclear Information System (INIS)

    Whitlock, R.W.

    1994-01-01

    This report contains schematic drawings for the pipe fittings for the Hanford waste tanks. Included are the modifications to the W-025 trench number-sign 31 leachate loadout piping, and also the modifications to the tanker trailers. The piping was modified to prevent spillage to the environment. The tankers were modified for loading and unloading purposes

  15. Water driven turbine/brush pipe cleaner

    Science.gov (United States)

    Werlink, Rudy J. (Inventor)

    1995-01-01

    Assemblies are disclosed for cleaning the inside walls of pipes and tubes. A first embodiment includes a small turbine with angled blades axially mounted on one end of a standoff support. An O-ring for stabilizing the assembly within the pipe is mounted in a groove within the outer ring. A replaceable circular brush is fixedly mounted on the opposite end of the standoff support and can be used for cleaning tubes and pipes of various diameters, lengths and configurations. The turbine, standoff support, and brush spin in unison relative to a hub bearing that is fixedly attached to a wire upstream of the assembly. The nonrotating wire is for retaining the assembly in tension and enabling return of the assembly to the pipe entrance. The assembly is initially placed in the pipe or tube to be cleaned. A pressurized water or solution source is provided at a required flow-rate to propel the assembly through the pipe or tube. The upstream water pressure propels and spins the turbine, standoff support and brush. The rotating brush combined with the solution cleans the inside of the pipe. The solution flows out of the other end of the pipe with the brush rotation controlled by the flow-rate. A second embodiment is similar to the first embodiment but instead includes a circular shaped brush with ring backing mounted in the groove of the exterior ring of the turbine, and also reduces the size of the standoff support or eliminates the standoff support.

  16. 33 CFR 106.415 - Amendment and audit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Amendment and audit. 106.415 Section 106.415 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MARITIME SECURITY MARINE SECURITY: OUTER CONTINENTAL SHELF (OCS) FACILITIES Outer Continental Shelf (OCS) Facility Security Plan (FSP) § 106.415 Amendment and...

  17. The Development of Boiler Pipes Used for 700°C A-USC-PP in China

    Science.gov (United States)

    Liu, Zhengdong; Bao, Hansheng; Xu, Songqian; Wang, Qijiang; Yang, Yujun; Zhang, Peng; Lei, Bingwang

    This paper introduces the progress of boiler pipes used for the manufacturing of 700°C advanced ultra-super-critical (A-USC) fossil fuel power plants (PP) in China, with the emphasis on the detailed advancements of G115 and CN617 pipes, including technical exploration, industrial production and microstructure-property investigation. G115 is a novel ferritic heat resistant steels developed by CISRI, which is an impressive candidate material to make pipes for the temperature up to 650°C. CN617 is a recent modification of Inconel617B and the CN617 pipe with the dimension of Φ 460 × 80 mm was successfully manufactured in China. Some newly available data associated with above materials will be released. G115 and CN617 are imposing candidate materials for the manufacturing of 700°C advanced ultra-super-critical (A-USC) fossil fuel power plants (PP) in China.

  18. Utilizing clad piping to improve process plant piping integrity, reliability, and operations

    International Nuclear Information System (INIS)

    Chakravarti, B.

    1996-01-01

    During the past four years carbon steel piping clad with type 304L (UNS S30403) stainless steel has been used to solve the flow accelerated corrosion (FAC) problem in nuclear power plants with exceptional success. The product is designed to allow ''like for like'' replacement of damaged carbon steel components where the carbon steel remains the pressure boundary and type 304L (UNS S30403) stainless steel the corrosion allowance. More than 3000 feet of piping and 500 fittings in sizes from 6 to 36-in. NPS have been installed in the extraction steam and other lines of these power plants to improve reliability, eliminate inspection program, reduce O and M costs and provide operational benefits. This concept of utilizing clad piping in solving various corrosion problems in industrial and process plants by conservatively selecting a high alloy material as cladding can provide similar, significant benefits in controlling corrosion problems, minimizing maintenance cost, improving operation and reliability to control performance and risks in a highly cost effective manner. This paper will present various material combinations and applications that appear ideally suited for use of the clad piping components in process plants

  19. Effect on mechanical properties of glass reinforced epoxy (GRE) pipe filled with different geopolymer filler molarity for piping application

    Science.gov (United States)

    Hashim, M. F. Abu; Abdullah, M. M. A.; Ghazali, C. M. R.; Hussin, K.; Binhussain, M.

    2017-04-01

    This study investigated the use of a novel white clay geopolymer as a filler to produce high strength glass reinforced epoxy pipe. It was found that using white clay geopolymer as filler gives better compressive strength to the glass reinforced epoxy pipe. The disadvantages of current glass reinforced epoxy pipes such low compressive strength which can be replaced by the composite pipes. Geopolymerization is an innovative technology that can transform several aluminosilicate materials into useful products called geopolymers or inorganic polymers. A series of glass reinforced epoxy pipe and glass reinforced epoxy pipe filled with 10 - 40 weight percentages white clay geopolymer filler with 4 Molarity and 8 Molarity were prepared. Morphology of white clay geopolymer filler surface was indicates using scanning electron microscopy. The additions of white clay geopolymer filler for both 4 Molarity and 8 Molarity show higher compressive strength than glass reinforced epoxy pipe without any geopolymer filler. The compressive test of these epoxy geopolymer pipe samples was determined using Instron Universal Testing under compression mode. Nonetheless, the compressive strength of glass reinforced epoxy pipe with white clay geopolymer filler continues to drop when added to 40 wt% of the geopolymer filler loading for both 4 Molarity and 8 Molarity. These outcomes showed that the mixing of geopolymer materials in epoxy system can be attained in this research.

  20. Piping vibrations measured during FFTF startup

    International Nuclear Information System (INIS)

    Anderson, M.J.

    1981-03-01

    An extensive vibration survey was conducted on the Fast Flux Test Facility piping during the plant acceptance test program. The purpose was to verify that both mechanical and flow induced vibration amplitudes were of sufficiently low level so that pipe and pipe support integrity would not be compromised over the plant design lifetime. Excitation sources included main heat transport sodium pumps, reciprocating auxiliary system pumps, EM pumps, and flow oscillations. Pipe sizes varied from one-inch to twenty-eight-inches in diameter. This paper describes the test plan; the instrumentation and procedures utilized; and the test results