WorldWideScience

Sample records for s1cr2 dose selection

  1. Phase diagram of ZnCr2pA12-2pS(Se)4 and Zn1-pCdpCr2S(Se)4

    International Nuclear Information System (INIS)

    Afif, K.; Benyoussef, A.; Hamedoun, M.; Hourmatallah, A.

    1999-06-01

    We compute the phase diagram of the nonmetallic compounds ZnCr2 p A1 2-2p S(Se) 4 (I[S,Se]) and Zn 1-p Cd p Cr 2 S(Se) 4 (II[S,Se]). We consider the bond-diluted Ising model on the spinel B site (S.B.S.) lattice with competitive exchange interactions, i.e. the ferromagnetic exchange interaction J 1 between nearest neighbours (n.n.) and the antiferromagnetic superexchange interaction J 2 between next-nearest neighbours' (n.n.n.) (and/or the more distant superexchange interactions J i (i > 1). Dilution and competition are found to be responsible for the spill glass phase and the percolation behaviour. (author)

  2. Thermodynamic properties of the solid solutions CuCr/sub 2/S/sub 4/ in Cu/sub 1///sub 2/M/sub 1///sub 2/Cr/sub 2/S/sub 4/ (M=Ga, In)

    Energy Technology Data Exchange (ETDEWEB)

    Titov, V.V.; Gordeev, I.V.; Kesler, Y.A.; Shchelkotunov, V.A.; Tret' yakov, Y.D.

    1985-09-01

    Using an adiabatic calorimeter and a quartz dilatometer, the temperature dependences of the heat capacity for the solid solutions CuCr/sub 2/S/sub 4/ in Cu/sub 1///sub 2/M/sub 1///sub 2/Cr/sub 2/S/sub 4/ (M - Ga, In) were determined, the different components of the heat capacity were evaluated, and the thermodynamic parameters of the magnetic transformation were calculated.

  3. Introduction to benchmark dose methods and U.S. EPA's benchmark dose software (BMDS) version 2.1.1

    International Nuclear Information System (INIS)

    Davis, J. Allen; Gift, Jeffrey S.; Zhao, Q. Jay

    2011-01-01

    Traditionally, the No-Observed-Adverse-Effect-Level (NOAEL) approach has been used to determine the point of departure (POD) from animal toxicology data for use in human health risk assessments. However, this approach is subject to substantial limitations that have been well defined, such as strict dependence on the dose selection, dose spacing, and sample size of the study from which the critical effect has been identified. Also, the NOAEL approach fails to take into consideration the shape of the dose-response curve and other related information. The benchmark dose (BMD) method, originally proposed as an alternative to the NOAEL methodology in the 1980s, addresses many of the limitations of the NOAEL method. It is less dependent on dose selection and spacing, and it takes into account the shape of the dose-response curve. In addition, the estimation of a BMD 95% lower bound confidence limit (BMDL) results in a POD that appropriately accounts for study quality (i.e., sample size). With the recent advent of user-friendly BMD software programs, including the U.S. Environmental Protection Agency's (U.S. EPA) Benchmark Dose Software (BMDS), BMD has become the method of choice for many health organizations world-wide. This paper discusses the BMD methods and corresponding software (i.e., BMDS version 2.1.1) that have been developed by the U.S. EPA, and includes a comparison with recently released European Food Safety Authority (EFSA) BMD guidance.

  4. Efficient Pd@MIL-101(Cr) hetero-catalysts for 2-butyne-1,4-diol hydrogenation exhibiting high selectivity

    KAUST Repository

    Yin, Dongdong

    2017-01-05

    Pd@MIL-101(Cr) hetero-catalysts have been successfully prepared using the metal-organic chemical vapour deposition (MOCVD) approach, by choosing [Pd(η-CH)(η-CH)] as a volatile precursor, and the hydrothermally stable metal-organic framework, MIL-101(Cr) as a support. The prepared Pd@MIL-101(Cr) hetero-catalysts characterized with various analytical techniques, exhibited highly monodispersed immobilized Pd nanoparticles in the MIL-101(Cr) cavities, while retaining the pristine crystallinity and porosity. The intact hybrid Pd@MIL-101(Cr) has been demonstrated to be an efficient catalyst for 2-butyne-1,4-diol hydrogenation with excellent activity, stability and selectivity (2-butene-1,4-diol (>94%)).

  5. Exfoliation and van der Waals heterostructure assembly of intercalated ferromagnet Cr1/3TaS2

    Science.gov (United States)

    Yamasaki, Yuji; Moriya, Rai; Arai, Miho; Masubuchi, Satoru; Pyon, Sunseng; Tamegai, Tsuyoshi; Ueno, Keiji; Machida, Tomoki

    2017-12-01

    Ferromagnetic van der Waals (vdW) materials are in demand for spintronic devices with all-two-dimensional-materials heterostructures. Here, we demonstrate mechanical exfoliation of magnetic-atom-intercalated transition metal dichalcogenide Cr1/3TaS2 from its bulk crystal; previously such intercalated materials were thought difficult to exfoliate. Magnetotransport in exfoliated tens-of-nanometres-thick flakes revealed ferromagnetic ordering below its Curie temperature T C ~ 110 K as well as strong in-plane magnetic anisotropy; these are identical to its bulk properties. Further, van der Waals heterostructure assembly of Cr1/3TaS2 with another intercalated ferromagnet Fe1/4TaS2 is demonstrated using a dry-transfer method. The fabricated heterojunction composed of Cr1/3TaS2 and Fe1/4TaS2 with a native Ta2O5 oxide tunnel barrier in between exhibits tunnel magnetoresistance (TMR), revealing possible spin injection and detection with these exfoliatable ferromagnetic materials through the vdW junction.

  6. Angular and dose dependence of CR-39 neutron response for shape-selected tracks

    CERN Document Server

    Tam, N C; Lakosi, L

    1999-01-01

    A shape selection method corresponding to an energy discrimination was used to eliminate unwanted events disturbing evaluation of CR-39 detectors in detecting tracks induced by particles both of perpendicular and oblique incidence. The angular dependence of the response was examined, detecting fast neutrons from sup 2 sup 5 sup 2 Cf with shape selection technique at various angles and distances. Also, the CR-39 track detectors with the sup 2 sup 5 sup 2 Cf source were exposed to high gamma-intensity of a sup 6 sup 0 Co irradiation facility in the range 0.1 to 4.5 kGy, similar to the exposures inside spent fuel assemblies. Using the two functions the lower limit of burnup could be determined by the method.

  7. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  8. Impact of x-ray dose on the response of CR-39 to 1-5.5 MeV alphas

    International Nuclear Information System (INIS)

    Rojas-Herrera, J.; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.

    2015-01-01

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray uences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K α and K β x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula

  9. Change of Cr atoms distribution in Fe85Cr15 alloy caused by 250 keV He+ ion irradiation to different doses

    International Nuclear Information System (INIS)

    Dubiel, S.M.; Żukrowski, J.

    2015-01-01

    Highlights: • Effect of He-ion irradiation dose on Fe 85 Cr 15 alloy. • Irradiation-induced clustering of Cr atoms. • Irradiation-caused reorientation of the surface magnetization vector. • Irradiation-caused increase of Fe-site spin-density. - Abstract: Redistribution of Cr atoms in a Fe 85 Cr 15 alloy caused by its irradiation with 250 keV He + ions to different doses, D = 8 ⋅ 10 16 , 16 ⋅ 10 16 and 48 ⋅ 10 16 ions/cm 2 was investigated by means of conversion electrons Mössbauer spectroscopy. The redistribution was expressed in terms of the Warren–Cowley short-range order parameters α 1 , α 2 and α 12 pertaining to the first (1NN), second (2NN) and both i.e. 1NN + 2NN shells, respectively. Clear evidence was found, both for non-irradiated and irradiated samples that the actual distribution of Cr atoms is characteristic of the shell, and for a given shell it depends on the irradiation dose. In particular, α 1 is positive, hence indicates an under population of Cr atoms in 1NN with respect to the random case, α 2 is negative, giving evidence thereby that 2NN is overpopulated by Cr atoms, and α 12 is weakly positive. Under the applied irradiation the number of Cr atoms in both neighbor shells decreased signifying thereby a clustering of Cr atoms. The underlying decrease of Cr concentration within the 1NN–2NN volume around the probe Fe atoms was estimated at 1.5 at.% ranging between 2.1 for the lowest and 0.8 at.% for the highest dose

  10. Thermodynamic properties of CuCr2S4 solid solutions in Cusub(1/2)Msub(1/2)Crsub(2)Ssub(4) (M - Ga, In)

    International Nuclear Information System (INIS)

    Titov, V.V.; Kesler, Ya.A.; Shelkotunov, V.A.; Gordeev, I.V.; Tret'yakov, Yu.D.

    1985-01-01

    By means of an adiabatic calorimeter and quartz dilatometer for CuCr 2 S 4 in Cusub(1/2)Msub(1/2)Crsub(2)Ssub(4) (M-Ga, In) temperature dependences of heat capacity are determined. The contribution of various components into heat capacity is estimated, thermodynamic parameters of magnetic transformation are calculated

  11. Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Herrera, J., E-mail: jimmy06@mit.edu; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2015-03-15

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K{sub α} and K{sub β} x-rays. The CR-39 detectors were then exposed to 1–5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.

  12. Anticonvulsant activity of a mGlu(4alpha) receptor selective agonist, (1S,3R,4S)-1-aminocyclopentane-1,2,4-tricarboxylic acid.

    Science.gov (United States)

    Chapman, A G; Talebi, A; Yip, P K; Meldrum, B S

    2001-07-20

    The metabotropic Group III agonist, (1S,3R,4S)-1-aminocyclopentane-1,2,4-tricarboxylic acid (ACPT-1), selective for the mGlu(4alpha) receptor, suppresses sound-induced seizures in DBA/2 mice following its intracerebroventricular (i.c.v.) administration (ED(50) 5.6 [2.9-10.7], nmol i.c.v., 15 min, clonic phase) and in genetically epilepsy-prone (GEP) rats following focal administration into the inferior colliculus (ED(50) 0.08 [0.01-0.50], nmol, 60 min, clonic phase). ACPT-1 also protects against clonic seizures induced in DBA/2 mice by the Group I agonist, (RS)-3,5-dihydroxyphenylglycine (3,5-DHPG) (ED(50) 0.60 [0.29-1.2], nmol i.c.v.) and by the Group III antagonist, (RS)-alpha-methylserine-O-phosphate (MSOP) (ED(50) 49.3 [37.9-64.1], nmol i.c.v.). Another Group III agonist, (RS)-4-phosphonophenyl-glycine (PPG), preferentially activating the mGlu(8) receptor, previously shown to protect against sound-induced seizures in DBA/2 mice and GEP rats, also protects against seizures induced in DBA/2 by 3,5-DHPG (ED(50) 3.7 [2.4-5.7], nmol i.c.v.) and by the Group III antagonist, MSOP (ED(50) 40.2 [21.0-77.0], nmol i.c.v.). At very high doses (500 nmol i.c.v. and above), Group III antagonists have pro-convulsant and convulsant activity. The anticonvulsant protection against sound-induced seizures in DBA/2 mice provided by a fully protective dose (20 nmol, i.c.v.) of the mGlu(4) receptor agonist ACPT-1, is partially reversed by the co-administration of the Group III antagonists, MSOP, (RS)-alpha-methyl-4-phosphonophenylglycine (MPPG) or (S)-2-amino-2-methyl-4-phosphonobutanoic acid (MAP4), in the 20-50 nmol dose range. At doses of 50-200 nmol, MPPG and MAP4 cause further reversal of the ACPT-1 anticonvulsant protection, while the MSOP effect on ACPT-1 protection is abolished at higher doses. In contrast, the anticonvulsant protection against sound-induced seizures in DBA/2 mice provided by a fully protective dose (20 nmol, i.c.v.) of the mGlu(8) receptor agonist PPG, is not

  13. Prominent ethanol sensing with Cr2O3 nanoparticle-decorated ZnS nanorods sensors

    Science.gov (United States)

    Sun, Gun-Joo; Kheel, Hyejoon; Ko, Tae-Gyung; Lee, Chongmu; Kim, Hyoun Woo

    2016-08-01

    ZnS nanorods and Cr2O3 nanoparticle-decorated ZnS nanorods were synthesized by using facile hydrothermal techniques, and their ethanol sensing properties were examined. X-ray diffraction and scanning electron microscopy revealed good crystallinity and size uniformity for the ZnS nanorods. The Cr2O3 nanoparticle-decorated ZnS nanorod sensor showed a stronger response to ethanol than the pristine ZnS nanorod sensor. The responses of the pristine and the decorated nanorod sensors to 200 ppm of ethanol at 300 °C were 2.9 and 13.8, respectively. Furthermore, under these conditions, the decorated nanorod sensor showed a longer response time (23 s) and a shorter recovery time (20 s) than the pristine one did (19 and 35 s, respectively). Consequently, the total sensing time of the decorated nanorod sensor (42 s) was shorter than that of the pristine one (55 s). The decorated nanorod sensor showed excellent selectivity to ethanol over other volatile organic compound gases including acetone, methanol, benzene, and toluene whereas the pristine one failed to show selectivity to ethanol over acetone. The improved sensing performance of the decorated nanorod sensor is attributed to a modulation of the width of the conduction channel and the height of the potential barrier at the ZnS-Cr2O3 interface accompanying the adsorption and the desorption of ethanol gas, and the greater surface-to-volume ratio of the decorated nanorods which was greater than that of the pristine one due to the existence of the ZnS-Cr2O3 interface.

  14. The two-dimensional thiophosphate CsCrP2S7

    Directory of Open Access Journals (Sweden)

    Kyounghee Kim

    2010-09-01

    Full Text Available The quaternary title compound, caesium chromium(III heptathiodiphosphate(V, CsCrP2S7, has been synthesized using the reactive halide flux method. It is isotypic with other AMP2S7 (A = alkali metal; M = Cr, V or In structures and consists of two-dimensional ∞2[CrP2S7]− layers extending parallel to (001 which are separated from each other by Cs+ ions (symmetry 2. The layer is built up from slightly distorted octahedral [CrS6] units (symmetry 2 and bent [P2S7] units consisting of two corner-sharing [PS4] tetrahedra. The [CrS6] octahedra share two edges and two corners with the [PS4] tetrahedra. There are only van der Waals interactions present between the layers. The Cs+ ions are located in this van der Waals gap and stabilize the structure through weak ionic interactions. The classical charge balance of the title compound can be expressed as [Cs+][Cr3+][P5+]2[S2−]7.

  15. Thermodynamic properties of CuCr/sub 2/S/sub 4/ solid solutions in Cusub(1/2)Msub(1/2) Crsub(2)Ssub(4) (M - Ga, In)

    Energy Technology Data Exchange (ETDEWEB)

    Titov, V.V.; Kesler, Ya.A.; Shelkotunov, V.A.; Gordeev, I.V.; Tret' yakov, Yu.D.

    1985-04-01

    By means of an adiabatic calorimeter and quartz dilatometer for CuCr/sub 2/S/sub 4/ in Cusub(1/2)Msub(1/2) Crsub(2)Ssub(4) (M-Ga, In) temperature dependences of heat capacity are determined. The contribution of various components into heat capacity is estimated, thermodynamic parameters of magnetic transformation are calculated.

  16. Thermodynamic properties of CdCr2S4

    International Nuclear Information System (INIS)

    Kesler, Ya.A.; Shchelkotunov, V.A.; Tret'yakov, Yu.D.; Kamyshova, V.K.; Gordeev, I.V.; Alferov, V.A.

    1977-01-01

    The true thermal capacity of ferromagnetic chromium spinel CdCr 2 S 4 has been measured in the temperature range of 172-673 K. Coefficient of linear expansion has been measured in the temperature range of 173-677 K. A change in heat content of the compound has been found by the mixing method (298-750 K). The lattice contribution into thermal capacity, the contribution of thermal expansion, the values of isothermal compressibility factor, and the Crueneisen constants have been calculated from true and mean heat capacity of CdCr 2 S 4 in a wide temperature range. The lattice energy V has been calculated for CdCr 2 S 4 ; it amounts -4226 kcal/mol

  17. Randomized study comparing full dose monotherapy (S-1 followed by irinotecan) and reduced dose combination therapy (S-1/oxaliplatin followed by S-1/irinotecan) as initial therapy for older patients with metastatic colorectal cancer

    DEFF Research Database (Denmark)

    Winther, Stine Braendegaard; Österlund, Pia; Berglund, Åke

    2017-01-01

    to select which older patients should receive therapy. Methods: The NORDIC 9 trial is a Nordic multicenter randomized phase II study comparing full dose monotherapy (S-1 30 mg/m2 twice daily days 1-14 every 3 weeks, followed by second line irinotecan 250-350 mg/m2 iv day 1 every 3 weeks or 180-250 mg/m2 iv...... day 1 every 2 weeks) with reduced dose combination therapy (S-1 20 mg/m2 days 1-14 + oxaliplatin 100 mg/m2 iv day 1 every 3 weeks, followed by second line S-1 20 mg/m2 days 1-14 + irinotecan 180 mg/m2 day 1 every 3 week) for older patients (≥70 years) with mCRC who are not candidates for full...... chance for tailored treatment strategies in these patients. Trial registration: EU Clinical Trial Register, EudraCT no. 2014-000394-39. Registered 05 May 2014....

  18. Programming MIL-101Cr for selective and enhanced CO2 adsorption at low pressure by postsynthetic amine functionalization.

    Science.gov (United States)

    Khutia, Anupam; Janiak, Christoph

    2014-01-21

    MIL-101Cr fully or partially (p) postsynthetically modified with nitro (-NO2) or amino (-NH2) groups was shown to be a robust, water stable, selective and enhanced carbon dioxide (CO2) adsorption material with the amine-functionality. The highly microporous amine-modified frameworks (up to 1.6 cm(3) g(-1) total pore volume) exhibit excellent thermal stability (>300 °C) with BET surface areas up to 2680 m(2) g(-1). At 1 bar (at 273 K) the gases CO2, CH4 and N2 are adsorbed up to 22.2 wt%, 1.67 wt% and 2.27 wt%, respectively. The two amine-modified MIL-101Cr-NH2 (4) and MIL-101Cr-pNH2 (5) showed the highest gas uptake capacities in the series with high ratios for the CO2 : N2 and CO2 : CH4 selectivities (up to 119 : 1 and 75 : 1, respectively, at 273 K). Comparison with non-modified MIL-101Cr traces the favorable CO2 adsorption properties of MIL-101Cr-NH2 (4) and MIL-101Cr-pNH2 (5) to the presence of the Lewis-basic amine groups. MIL-101Cr-NH2 (4) has a high isosteric heat of adsorption of 43 kJ mol(-1) at zero surface coverage and also >23 kJ mol(-1) over the entire adsorption range, which is well above the heat of liquefaction of bulk CO2. Large CO2 uptake capacities of amine-functionalized 4 and 5, coupled with high adsorption enthalpy, high selectivities and proven long-term water stability, make them suitable candidates for capturing CO2 at low pressure from gas mixtures including the use as a CO2 sorbent from moist air.

  19. Prediction of half-metallic properties in TlCrS{sub 2} and TlCrSe{sub 2} based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Hashimzade, F.M.; Huseinova, D.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Jahangirli, Z.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Institute of Radiation Problems, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Mehdiyev, B.H., E-mail: bachschi@yahoo.de [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan)

    2017-08-01

    Highlights: • Half-metallic properties of TlCrS2, TlCrSe2 and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). • Total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS2 and TlCrSSe, while total magnetic moment TlCrSe2 decreases with increasing volume, approaching to integer value 3 μB. • The states at the Fermi level in the case of spin-up channel consist of a hybridization of p-states of the atom S(Se) with d-states of Cr. - Abstract: Half-metallic properties of TlCrS{sub 2}, TlCrSe{sub 2} and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). The results of calculations show that TlCrS{sub 2} and TlCrSSe are half-metals with energy gap (E{sub g}) ∼0.12 eV for spin-down channel. Strong hybridization of p-state of chalchogen and d-state of Cr leads to bonding and antibonding states and subsequently to the appearance of a gap in spin-down channel of TlCrS{sub 2} and TlCrSSe. In the case of TlCrSe{sub 2}, there is a partial hybridization and p-state is partially present in the DOS at Fermi level making this compound nearly half-metallic. The present calculations revealed that total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS{sub 2} and TlCrSSe, while total magnetic moment of TlCrSe{sub 2} decreases with increasing volume approaching to integer value 3 μB.

  20. Residual stresses in 2 1/4Cr1Mo welds

    International Nuclear Information System (INIS)

    Fidler, R.; Jerram, K.

    1978-01-01

    Two separate investigations, initiated in an attempt to explain the large amount of residual stress scatter previously observed in the weld metal of eighteen nominally identical thick-section 2 1/4Cr1Mo butt welds, are described in this paper. The first examined the detailed surface residual stress distributions in 2 1/4Cr1Mo manual arc circumferential butt welds in 80mm and 100mm thick 1/2Cr1/2Mo1/4V steam pipe. High residual stresses were found in the regions of overlap between adjacent weld beads, with low values in virgin weld metal. The second utilised single pass manual metal arc bead-in-groove welds to investigate the effects of preheat and weld metal composition on weld metal residual stresses. In four weld metals, mild steel, 1/2Cr1/2Mo1/4V, 1Cr1/2Mo, and 2 1/4Cr1Mo, the residual stresses were very similar, becoming less tensile (or more compressive) with increase of preheat, while the residual stresses in the fifth weld metal (12Cr) were significantly different, being compressive and less affected by preheat. In both investigations the effects have been described in terms of the basic metallurgical phenomena occurring in the weld metal. (author)

  1. Enhanced photodegradation activity of methyl orange over Ag2CrO4/SnS2 composites under visible light irradiation

    International Nuclear Information System (INIS)

    Luo, Jin; Zhou, Xiaosong; Ma, Lin; Xu, Xuyao; Wu, Jingxia; Liang, Huiping

    2016-01-01

    Highlights: • Novel visible-light-driven Ag 2 CrO 4 /SnS 2 composites are synthesized. • Ag 2 CrO 4 /SnS 2 exhibits higher photocatalytic activity than pure Ag 2 CrO 4 and SnS 2 . • Ag 2 CrO 4 /SnS 2 exhibits excellent stability for the photodegradation of MO. • The possible photocatalytic mechanism was discussed in detail. - Abstract: Novel Ag 2 CrO 4 /SnS 2 composites were prepared by a simple chemical precipitation method and characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, UV–vis diffuse reflectance spectroscopy and photoluminescence spectroscopy. The visible light photocatalytic tests showed that the Ag 2 CrO 4 /SnS 2 composites enhanced photocatalytic activities for the photodegradation of methyl orange (MO) under visible light irradiation (λ > 420 nm), and the optimum rate constant of Ag 2 CrO 4 /SnS 2 at a weight content of 1.0% Ag 2 CrO 4 for the degradation of MO was 2.2 and 1.5 times larger than that of pure Ag 2 CrO 4 and SnS 2 , respectively. The improved activity could be attributed to high separation efficiency of photogenerated electrons-hole pairs on the interface of Ag 2 CrO 4 and SnS 2 , which arised from the synergistic effect between Ag 2 CrO 4 and SnS 2 . Moreover, the possible photocatalytic mechanism with superoxide radical anions and holes species as the main reactive species in photocatalysis process was proposed on the basis of experimental results.

  2. Selective Oxidation of Glycerol with 3% H2O2 Catalyzed by LDH-Hosted Cr(III Complex

    Directory of Open Access Journals (Sweden)

    Gongde Wu

    2015-11-01

    Full Text Available A series of layered double hydroxides (LDHs –hosted sulphonato-salen Cr(III complexes were prepared and characterized by various physico-chemical measurements, such as Fourier transform infrared spectroscopy (FTIR, ultraviolet-visible spectroscopy (UV-Vis, powder X-ray diffraction (XRD, transmission electron microscope (TEM, scanning electron microscope (SEM and elemental analysis. Additionally, their catalytic performances were investigated in the selective oxidation of glycerol (GLY using 3% H2O2 as an oxidant. It was found that all the LDH-hosted Cr(III complexes exhibited significantly enhanced catalytic performance compared to the homogeneous Cr(III complex. Additionally, it was worth mentioning that the metal composition of LDH plates played an important role in the catalytic performances of LDH-hosted Cr(III complex catalysts. Under the optimal reaction conditions, the highest GLY conversion reached 85.5% with 59.3% of the selectivity to 1,3-dihydroxyacetone (DHA. In addition, the catalytic activity remained after being recycled five times.

  3. Selective and sensitive speciation analysis of Cr(VI) and Cr(III), at sub-μgL-1 levels in water samples by electrothermal atomic absorption spectrometry after electromembrane extraction.

    Science.gov (United States)

    Tahmasebi, Zeinab; Davarani, Saied Saeed Hosseiny

    2016-12-01

    In this work, electromembrane extraction in combination with electrothermal atomic absorption spectrometry (ET-AAS) was investigated for speciation, preconcentration and quantification of Cr(VI) and Cr(III) in water samples through the selective complexation of Cr(VI) with 1,5-diphenylcarbazide (DPC) as a complexing agent. DPC reduces Cr(VI) to Cr(III) ions and then Cr(III) species are extracted based on electrokinetic migration of their cationic complex (Cr(III)-DPC) toward the negative electrode placed in the hollow fiber. Also, once oxidized to Cr(VI), Cr(III) ions in initial sample were determined by this procedure. The influence of extraction parameters such as pH, type of organic solvent, chelating agent concentration, stirring rate, extraction time and applied voltage were evaluated following a one-at-a-time optimization approach. Under optimized conditions, the extracted analyte was quantified by ETAAS, with an acceptable linearity in the range of 0.05-5ngmL -1 (R 2 value=0.996), and a repeatability (%RSD) between 3.7% and 12.2% (n=4) for 5.0 and 1.0ngmL -1 of Cr(VI), respectively. Also, we obtained an enrichment factor of 110 that corresponded to the recovery of 66%. The detection limit (S/N ratio of 3:1) was 0.02ngmL -1 . Finally, this new method was successfully employed to determine Cr(III) and Cr(VI) species in real water samples. Copyright © 2016. Published by Elsevier B.V.

  4. Complement receptors type 1 (CR1, CD35) and 2 (CR2, CD21) cooperate in the binding of hydrolyzed complement factor 3 (C3i) to human B lymphocytes

    DEFF Research Database (Denmark)

    Leslie, Robert Graham Quinton; Prodinger, Wolfgang Maria; Nielsen, Claus Henrik

    2003-01-01

    The C3b-binding receptor, CR1/CD35, supports CR2/CD21-mediated activation of complement by human B lymphocytes, possibly by associating with CR2 to promote or stabilize the binding of hydrolyzed C3 (C3i), the primary component of the AP convertase, C3i-Bb. To evaluate this hypothesis, we examined...... the uptake kinetics and binding equilibria for C3i dimer interaction with human blood cells in the absence and presence of CR1- and CR2-blocking mAb. C3i displayed dual uptake kinetics to B lymphocytes, comprising of rapid binding to CR1 and slower binding to CR2. The forward rate constants (k(1)) for CR1...... and CR2, operating independently, differed ca. 9-fold (k(1)=193+/-9.4 and 22.2+/-6.0 x 10(3) M(-1)s(-1), respectively). Equilibrium binding of C3i to B lymphocytes was also complex, varying in strength by ca. 13-fold over the C3i concentration range examined. The maximum association constant (K(a, max...

  5. Desensitization by progressive up-titration prevents first-dose effects on the heart: guinea pig study with ponesimod, a selective S1P1 receptor modulator.

    Directory of Open Access Journals (Sweden)

    Markus Rey

    Full Text Available Ponesimod, a selective S1P1 receptor modulator, reduces the blood lymphocyte count in all tested species by preventing egress of T and B cells from thymus and peripheral lymphoid organs. In addition, ponesimod transiently affects heart rate and atrioventricular (AV conduction in humans, effects not observed in mice, rats, and dogs with selective S1P1 receptor modulators, suggesting that the regulation of heart rate and rhythm is species dependent. In the present study, we used conscious guinea pigs implanted with a telemetry device to investigate the effects of single and multiple oral doses of ponesimod on ECG variables, heart rate, and blood pressure. Oral administration of ponesimod did not affect the sinus rate (P rate but dose-dependently induced AV block type I to III. A single oral dose of 0.1 mg/kg had no effect on ECG variables, while a dose of 3 mg/kg induced AV block type III in all treated guinea pigs. Repeated oral dosing of 1 or 3 mg/kg ponesimod resulted in rapid desensitization, so that the second dose had no or a clearly reduced effect on ECG variables as compared with the first dose. Resensitization of the S1P1 receptor in the heart was concentration dependent. After desensitization had been induced by the first dose of ponesimod, the cardiac system remained desensitized as long as the plasma concentration was ≥75 ng/ml. By using a progressive up-titration regimen, the first-dose effect of ponesimod on heart rate and AV conduction was significantly reduced due to desensitization of the S1P1 receptor. In summary, conscious guinea pigs implanted with a telemetry device represent a useful model to study first-dose effects of S1P1 receptor modulators on heart rate and rhythm. This knowledge was translated to a dosing regimen of ponesimod to be tested in humans to avoid or significantly reduce the first-dose effects.

  6. Investigation of structural changes in chiral magnet Cr{sub 1∕3}NbS{sub 2} under application of pressure

    Energy Technology Data Exchange (ETDEWEB)

    Mito, M., E-mail: mitoh@mns.kyutech.ac.jp; Tsuruta, K.; Deguchi, H. [Graduate School of Engineering, Kyushu Institute of Technology, Kitakyushu 804-8550 (Japan); Tajiri, T. [Faculty of Science, Fukuoka University, Fukuoka 814-0180 (Japan); Kishine, J. [Graduate School of Arts and Sciences, The Open University of Japan, Chiba 261-8586 (Japan); Inoue, K. [Graduate School of Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Institute for Advanced Materials Research, Hiroshima University, Higashihiroshima 739-8526 (Japan); Center for Chiral Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Kousaka, Y. [Graduate School of Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Center for Chiral Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Nakao, Y. [Department of Physics and Mathematics, Aoyama Gakuin University, Sagamihara 229-8558 (Japan); Akimitsu, J. [Graduate School of Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Center for Chiral Science, Hiroshima University, Higashihiroshima 739-8526 (Japan); Department of Physics and Mathematics, Aoyama Gakuin University, Sagamihara 229-8558 (Japan)

    2015-05-14

    We perform structural analysis experiments on the chiral magnet Cr{sub 1∕3}NbS{sub 2}, in which Cr{sup 3+} ions are inserted between hexagonal NbS{sub 2} layers. The noncentrosymmetrical nature of the inserted Cr{sup 3+} appears as a distorted CrS{sub 6} octahedron. Under the application of hydrostatic pressure, the lattice shrinks significantly along the c-axis rather than the a-axis. However, at a pressure P of approximately 3–4 GPa, a kink in the rate of decrease in the lattice parameters is observed, and the slight movement of a Nb atom along the c-axis brings about a decrease in the distortion of the CrS{sub 6} octahedron. This structural change qualitatively suggests a decrease in the strength of the Dzyaloshinskii-Moriya (D-M) interaction. Under hydrostatic pressure, the magnetic ordering temperature T{sub C} decreases, and dT{sub C}/dP exhibits a slight change at around 3 GPa. A series of experiments indicates that the change in the structural symmetry of the CrS{sub 6} octahedron influences the exchange network between Cr{sup 3+} ions as well as the D-M interaction.

  7. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  8. Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode

    Directory of Open Access Journals (Sweden)

    Puja Saxena

    2004-12-01

    Full Text Available Abstract: A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13-tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumtetraphenyl borate composition 1:4:1:1 with a Nernstian slope of 19.0 mV per decade of concentration between pH 3.0 and 6.5. This electrode has been found to be chemically inert and of adequate stability with a response time of 20 s and was used over a period of 100 d with good reproducibility (S= 0.3 mV. The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 30% (v/v content of methanol and ethanol. The potentiometric selectivity coefficient values indicate that the membrane sensor is highly selective for Cr(III ions over a number of monovalent, divalent and trivalent cations. The membrane electrode has also been successfully used to determine Cr3+ in various food materials.

  9. Crystal and magnetic structures of Cr{sub 1∕3}NbSe{sub 2} from neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Gubkin, A. F., E-mail: agubkin@imp.uran.ru; Baranov, N. V. [M.N. Miheev Institute of Metal Physics, Russian Academy of Sciences, 620990 Yekaterinburg (Russian Federation); Institute of Natural Sciences, Ural Federal University, 620083 Yekaterinburg (Russian Federation); Proskurina, E. P.; Sherokalova, E. M.; Selezneva, N. V. [Institute of Natural Sciences, Ural Federal University, 620083 Yekaterinburg (Russian Federation); Kousaka, Y.; Akimitsu, J. [Graduate School of Science, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Center for Chiral Science, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Miao, P.; Lee, S.; Ishikawa, Y.; Torii, S. [Institute of Materials Structure Science, KEK, Tokai, Ibaragi 319-1106 (Japan); Zhang, J. [Institute of Materials Structure Science, KEK, Tokai, Ibaragi 319-1106 (Japan); China Spallation Neutron Source, Institute of High Energy Physics, Chinese Academy of Sciences, Dongguan 523803, Guangdong (China); Kamiyama, T. [Institute of Materials Structure Science, KEK, Tokai, Ibaragi 319-1106 (Japan); Sokendai (Graduate University for Advanced Studies), KEK, Tokai, Ibaragi 319-1106 (Japan); Campo, J. [Aragón Materials Science Institute (CSIC - University of Zaragoza), 50009 Zaragoza (Spain)

    2016-01-07

    Neutron diffraction measurements of the Cr intercalated niobium diselenide Cr{sub 1∕3}NbSe{sub 2} together with magnetization measurements have revealed that this compound exhibits ferromagnetic ordering below T{sub C} = 96 K unlike a chiral helimagnetic order observed in the sulfide compound Cr{sub 1∕3}NbS{sub 2}. As derived from neutron diffraction data, the Cr magnetic moments μ{sub Cr} = 2.83 ± 0.03 μ{sub B} in Cr{sub 1∕3}NbSe{sub 2} are aligned within basal plane. The discrepancy in the magnetic states of Cr{sub 1∕3}NbS{sub 2} and Cr{sub 1∕3}NbSe{sub 2} is ascribed to the difference in the preferential site occupation of Cr ions in crystal lattices. In Cr{sub 1∕3}NbSe{sub 2}, the Cr ions are predominantly distributed over 2b Wyckoff site, which determines a centrosymmetric character of the crystal structure unlike Cr{sub 1∕3}NbS{sub 2}, where the Cr ions are mainly located in 2c position and the crystal structure is non-centrosymmetric.

  10. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  11. Out-of-plane spin-orientation dependent magnetotransport properties in the anisotropic helimagnet CR1/3NbS2 [Spin-Orbit Coupling Induced Anisotropy in the Magnetotransport of the Chiral Helimagnet Cr1=3NbS2

    International Nuclear Information System (INIS)

    Bornstein, Alexander C.; Chapman, Benjamin J.; Ghimire, Nirmal J.; Oak Ridge National Lab.; Technology Div.); Mandrus, David G.; Oak Ridge National Lab.; Technology Div.); Parker, David S.; Technology Div.); Lee, Minhyea

    2015-01-01

    Understanding the role of spin-orbit coupling (SOC) has been crucial for controlling magnetic anisotropy in magnetic multilayer films. It has been shown that electronic structure can be altered via interface SOC by varying the superlattice structure, resulting in spontaneous magnetization perpendicular or parallel to the plane. In lieu of magnetic thin films, we study the similarly anisotropic helimagnet Cr1/3NbS2 where the spin-polarization direction, controlled by the applied magnetic field, can modify the electronic structure. As a result, the direction of spin polarization can modulate the density of states and in turn affect the in-plane electrical conductivity. In Cr1/3NbS2, we found an enhancement of in-plane conductivity when the spin polarization is out-of-plane as compared to in-plane spin polarization. This is consistent with the increase in density of states near the Fermi energy at the same spin configuration, found from first-principles calculations. We also observe unusual field dependence of the Hall signal in the same temperature range. This is unlikely to originate from the noncollinear spin texture but rather further indicates strong dependence of electronic structure on spin orientation relative to the plane

  12. Determination of thermal properties of Cs2Cr2O7(s,l) by high temperature Calvet calorimetry

    International Nuclear Information System (INIS)

    Prasad, R.; Agarwal, R.; Roy, K.N.; Iyer, V.S.; Venugopal, V.; Sood, D.D.

    1989-01-01

    Enthalpy increments have been determined for caesium dichromate in the temperature range 335 to 826 K using a high temperature Calvet micro calorimeter. A solid-solid transition has been observed at (620.5±1.5 K) and the melting temperature was found to be (657.0±1.0) K. The corresponding enthalpy values are 15.6±0.2) kJ/mol and 17.0±0.22) kJ/mol. The results thus obtained are utilised for the evaluation of molar heat capacities, standard entropies and free energy functions for Cs 2 Cr 2 O 7 (s,l). The enthalpy increment values were fitted to a polynomial and can be presented by eqs. (1) to (3), respectivley: (1) (H T 0 -H 0 298.15 )(Cs 2 Cr 2 O 7 ,s) (J/mol)=-6.410x10 4 +1.939x10 2 T(K)+7.441x10 -2 T(K) 2 (335 to 620.5 K), (2) (H T 0 -H 0 298.15 )(Cs 2 Cr 2 O 7 ,s) (J/mol)=1.313x10 6 -4.137x10 3 T(K)+3.517T(K) 2 (620.5 to 656 K), (3) (H T 0 -H 0 298.15 )(Cs 2 Cr 2 O 7 ,l) (J/mol)=-1.218x10 5 +3.890x10 2 T(K) (657 to 826 K). (orig.)

  13. Analgesic efficacy of CR4056, a novel imidazoline-2 receptor ligand, in rat models of inflammatory and neuropathic pain

    Directory of Open Access Journals (Sweden)

    Ferrari F

    2011-04-01

    Full Text Available Flora Ferrari1, Simonetta Fiorentino1, Laura Mennuni1, Paolo Garofalo1, Ornella Letari1, Stefano Mandelli2, Antonio Giordani3, Marco Lanza1, Gianfranco Caselli11Department of Pharmacology and Toxicology; 2Department of Medicinal Chemistry; 3R&D Chemistry Drug Development and OS, Rottapharm S.p.A., Monza (MB, ItalyAbstract: Two decades of investigations have failed to unequivocally clarify the functions and the molecular nature of imidazoline-2 receptors (I2R. However, there is robust pharmacological evidence for the functional modulation of monoamino oxidase (MAO and other important enzyme activities by I2 site ligands. Some compounds of this class proved to be active experimental tools in preventing both experimental pain and opioid tolerance and dependence. Unfortunately, even though these compounds bind with high potency to central I2 sites, they fail to represent a valid clinical opportunity due to their pharmacokinetic, selectivity or side-effects profile. This paper presents the preclinical profile of a novel I2 ligand (2-phenyl-6-(1H-imidazol-1ylquinazoline; [CR4056] that selectively inhibits the activity of human recombinant MAO-A in a concentration-dependent manner. A sub-chronic four day oral treatment of CR4056 increased norepinephrine (NE tissue levels both in the rat cerebral cortex (63.1% ± 4.2%; P<0.05 and lumbar spinal cord (51.3% ± 6.7%; P < 0.05. In the complete Freund's adjuvant (CFA rat model of inflammatory pain, CR4056 was found to be orally active (ED50 = 5.8 mg/kg, by mouth [p.o.]. In the acute capsaicin model, CR4056 completely blocked mechanical hyperalgesia in the injured hind paw (ED50 = 4.1 mg/kg, p.o.; ED100 = 17.9 mg/kg, p.o.. This effect was dose-dependently antagonized by the non-selective imidazoline I22 antagonist idazoxan. In rat models of neuropathic pain, oral administration of CR4056 significantly attenuated mechanical hyperalgesia and allodynia. In summary, the present study suggests a novel

  14. Crystallochemical features of solid solutions based on Ga/sub 2/3/Cr/sub 2/S/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    Titov, V.V.; Kesler, Ya.A.; Gordeev, I.V.; Stupnikov, V.A.

    1988-04-01

    Ga/sub 2/3/Cr/sub 2/S/sub 4/ shows a rare type of phase transition where increases in temperature and pressure produce the disordered modification. A source of disordering can be isomorphous substitution in the tetrahedral sublattice. The authors therefore made and examined solid solutions of Ga/sub (2/3-2x/3)/M/sub x/(Cr/sub 2/)S/sub 4/ type, where M = Fe, Co, Ni, Cu. Specimens containing Fe and show a quasi-continuous solid-solution series, where the Fe system obeys Vegard's rule. Specimens containing nickel show a narrow ordering range. The most interesting results have been obtained for specimens containing copper. Cu/sub x/Ga/sub 2/3(1-x)/Cr/sub 2/S/sub 4/ specimens show a transition from a structure ordered on the tetrahedral positions, symmetry F/anti/43m, to the normal-spinel structure, Fd3m.

  15. 1s2p Resonant Inelastic X-ray Scattering Magnetic Circular Dichroism as a probe for the local and non-local orbitals in CrO 2

    NARCIS (Netherlands)

    Zimmermann, Patric; Bouldi, Nadejda; Hunault, Myrtille O.j.y.; Sikora, Marcin; Ablett, James M.; Rueff, Jean Pascal; Lebert, Blair; Sainctavit, Philippe; De Groot, Frank M.f.; Juhin, Amélie

    2018-01-01

    We have determined the magnetic ground state of the half-metal CrO2 based on 1s2p Resonant Inelastic X-ray Scattering Magnetic Circular Dichroism (RIXS-MCD) experiments. The two-dimensional RIXS-MCD map displays the 1s X-ray absorption spectrum combined with the 1s2p X-ray emission decay, where

  16. Selection of appropriate end-points (pCR vs 2yDFS) for tailoring treatments with prediction models in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Valentini, Vincenzo; Stiphout, Ruud G.P.M. van; Lammering, Guido; Gambacorta, Maria A.; Barba, Maria C.; Bebenek, Marek; Bonnetain, Franck; Bosset, Jean F.; Bujko, Krzysztof; Cionini, Luca; Gerard, Jean P.; Rödel, Claus; Sainato, Aldo; Sauer, Rolf; Minsky, Bruce D.; Collette, Laurence; Lambin, Philippe

    2015-01-01

    Purpose: Personalized treatments based on predictions for patient outcome require early characterization of a rectal cancer patient’s sensitivity to treatment. This study has two aims: (1) identify the main patterns of recurrence and response to the treatments (2) evaluate pathologic complete response (pCR) and two-year disease-free survival (2yDFS) for overall survival (OS) and their potential to be relevant intermediate endpoints to predict. Methods: Pooled and treatment subgroup analyses were performed on five large European rectal cancer trials (2795 patients), who all received long-course radiotherapy with or without concomitant and/or adjuvant chemotherapy. The ratio of distant metastasis (DM) and local recurrence (LR) rates was used to identify patient characteristics that increase the risk of recurrences. Findings: The DM/LR ratio decreased to a plateau in the first 2 years, revealing it to be a critical follow-up period. According to the patterns of recurrences, three patient groups were identified: 5–15% had pCR and were disease free after 2 years (excellent prognosis), 65–75% had no pCR but were disease free (good prognosis) and 15–30% had neither pCR nor 2yDFS (poor prognosis). Interpretation: Compared with pCR, 2yDFS is a stronger predictor of OS. To adapt treatment most efficiently, accurate prediction models should be developed for pCR to select patients for organ preservation and for 2yDFS to select patients for more intensified treatment strategies

  17. Tunable regioselectivity in 1,3-butadiene polymerization by using 2,6-bis(dimethyl-2-oxazolin-2-yl)pyridine incorporated transition metal (Cr, Fe and Co) catalysts

    KAUST Repository

    Gong, Dirong; Liu, Wen; Pan, Weijing; Chen, Tao; Jia, Xiaoyu; Huang, Kuo-Wei; Zhang, Xuequan

    2015-01-01

    Tridentate complexes Cr(III)Cl3L, [L = 2,6-bis(dimethyl-2-oxazolin-2-yl) pyridine], Fe(III)Cl3L, Fe(II)Cl2L and Co(II)Cl2L have been prepared and fully characterized. The solid structures of Cr(III)Cl3L, Fe(III)Cl3L and Co(II)Cl2L have been revealed by single crystal X-ray diffraction, and the Cr(III)Cl3L and Fe(III)Cl3L complexes both exhibit a distorted octahedral geometry, while the Co(II)Cl2L complex has a trigonal bipyramidal conformation. Four complexes have been examined in regioselective polymerization of butadiene in combination with MAO in toluene at room temperature. The trans-1,4, cis-1,4 enchainment of resultant polybutadiene are controlled by the metal center. Activated by MAO, complex Cr(III)Cl3L produces high level of trans-1,4 selectivity (trans-1,4 up to 93.3%) with moderate polymer yield, complexes Fe(III)Cl3L and Fe(II)Cl2L both show equal cis-1,4 and trans-1,4 with minor 1,2 selectivity (<10%), and Co(II)Cl2L catalyst displays predominated cis-1,4 selectivity, which can be shifted to 1,2 selectivity by adding PPh3 as an additive. Thus, tuning of the cis-1,4, trans-1,4 and 1,2 selectivity in full range via central metal and additive chosen by these 2,6-bis(dimethyl-2-oxazolin-2-yl) pyridine supported catalysts has been achieved. © 2015 Elsevier B.V. All rights reserved.

  18. Tunable regioselectivity in 1,3-butadiene polymerization by using 2,6-bis(dimethyl-2-oxazolin-2-yl)pyridine incorporated transition metal (Cr, Fe and Co) catalysts

    KAUST Repository

    Gong, Dirong

    2015-05-21

    Tridentate complexes Cr(III)Cl3L, [L = 2,6-bis(dimethyl-2-oxazolin-2-yl) pyridine], Fe(III)Cl3L, Fe(II)Cl2L and Co(II)Cl2L have been prepared and fully characterized. The solid structures of Cr(III)Cl3L, Fe(III)Cl3L and Co(II)Cl2L have been revealed by single crystal X-ray diffraction, and the Cr(III)Cl3L and Fe(III)Cl3L complexes both exhibit a distorted octahedral geometry, while the Co(II)Cl2L complex has a trigonal bipyramidal conformation. Four complexes have been examined in regioselective polymerization of butadiene in combination with MAO in toluene at room temperature. The trans-1,4, cis-1,4 enchainment of resultant polybutadiene are controlled by the metal center. Activated by MAO, complex Cr(III)Cl3L produces high level of trans-1,4 selectivity (trans-1,4 up to 93.3%) with moderate polymer yield, complexes Fe(III)Cl3L and Fe(II)Cl2L both show equal cis-1,4 and trans-1,4 with minor 1,2 selectivity (<10%), and Co(II)Cl2L catalyst displays predominated cis-1,4 selectivity, which can be shifted to 1,2 selectivity by adding PPh3 as an additive. Thus, tuning of the cis-1,4, trans-1,4 and 1,2 selectivity in full range via central metal and additive chosen by these 2,6-bis(dimethyl-2-oxazolin-2-yl) pyridine supported catalysts has been achieved. © 2015 Elsevier B.V. All rights reserved.

  19. Optimization of paediatric radiation doses with CR systems

    International Nuclear Information System (INIS)

    Zatelli, Giovanna; Mazzocchi, S.; Ciccarone, A.; Fonda, C.; De Otto, G.

    2008-01-01

    Full text: Radiation protection of paediatric patients is a primary objective in paediatric radiology due the higher life expectance of the little patients undergoing radiology examinations and due to the higher radiosensitivity of tissues. Aim of this work is the study of the optimization process in paediatric doses needed after the recent installation of a new Computed Radiography System in the Radiology of the Meyer paediatric Hospital, in Florence, Italy. This process involves both the use of new dedicated digitizer (Agfa DX-S) and elaboration software (Agfa NX2.0). The choice of the DX-S systems has been performed in consideration of high resolution (Scanhead technology - DirectriX detector), image sharpness and portability of the cassettes that make DX-S ideal in paediatric applications as neonatal intensive care. The NX software for image processing has been installed with the 'Paediatric' licence that optimizes paediatric images especially for exposures of premature newborns. Paediatric NX automatically selects the paediatric age group, depending on the patient's birth date. Each age group contains enhanced algorithms and settings adapted to age group, for optimized visibility of fine details. All the CR system has been accepted by mean of quality control acceptance tool AGFA AutoQC2, and all the automatic exposure control devices installed on radiographic devices were previously calibrated in accordance to literature with signal to noise vs dose considerations [S. Mazzocchi et al. 'AEC set-up optimization with computed radiography imaging' Radiat. Prot. Dosim. 117, 169-173 2005]. Paediatric patients were then divided into age-weight categories and the Entrance Surface Doses (ESD) were calculated by output x-rays measurements. ESD for thorax examinations were correlated to the image evaluations performed by experienced radiologists following European Guidelines on quality criteria for diagnostic radiographic images in paediatrics (EUR 16261, European

  20. The CrIIL reduction of [2Fe-2S] ferredoxins and site of attachment of CrIII using 1H NMR and site-directed mutagenesis.

    Science.gov (United States)

    Im, S C; Worrall, J A; Liu, G; Aliverti, A; Zanetti, G; Luchinat, C; Bertini, I; Sykes, A G

    2000-04-17

    The recently reported NMR solution structure of FeIIIFeIII parsley FdI has made possible 2D NOESY NMR studies to determine the point of attachment of CrIIIL in FeIIIFeIII...CrIIIL. The latter Cr-modified product was obtained by reduction of FeIIIFeIII parsley and spinach FdI forms with [Cr(15-aneN4) (H2O)2]2+ (15-aneN4 = 1,4,8,12-tetraazacyclopentadecane), referred to here as CrIIL, followed by air oxidation and chromatographic purification. From a comparison of NMR cross-peak intensities of native and Cr-modified proteins, two surface sites designated A and B, giving large paramagnetic CrIIIL broadening of a number of amino acid peaks, have been identified. The effects at site A (residues 19-22, 27, and 30) are greater than those at site B (residues 92-94 and 96), which is on the opposite side of the protein. From metal (ICP-AES) and electrospray ionization mass spectrometry (EIMS) analyses on the Cr-modified protein, attachment of a single CrIIIL only is confirmed for both parsley and spinach FdI and FdII proteins. Electrostatic interaction of the 3+ CrIIIL center covalently attached to one protein molecule (charge approximately -18) with a second (like) molecule provides an explanation for the involvement of two regions. Thus for 3-4 mM FeIIIFeIII...CrIIIL solutions used in NMR studies (CrIIIL attached at A), broadening effects due to electrostatic interactions at B on a second molecule are observed. Experiments with the Cys18Ala spinach FdI variant have confirmed that the previously suggested Cys-18 at site A is not the site of CrIIIL attachment. Line broadening at Val-22 of A gives the largest effect, and CrIIIL attachment at one or more adjacent (conserved) acidic residues in this region is indicated. The ability of CrIIL to bind in some (parsley and spinach) but not all cases (Anabaena variabilis) suggests that intramolecular H-bonding of acidic residues at A is relevant. The parsley and spinach FeIIFeIII...CrIIIL products undergo a second stage of reduction

  1. ZnCr2S4: Highly effective photocatalyst converting nitrate into N2 without over-reduction under both UV and pure visible light.

    Science.gov (United States)

    Yue, Mufei; Wang, Rong; Cheng, Nana; Cong, Rihong; Gao, Wenliang; Yang, Tao

    2016-08-03

    We propose several superiorities of applying some particular metal sulfides to the photocatalytic nitrate reduction in aqueous solution, including the high density of photogenerated excitons, high N2 selectivity (without over-reduction to ammonia). Indeed, ZnCr2S4 behaved as a highly efficient photocatalyst, and with the assistance of 1 wt% cocatalysts (RuOx, Ag, Au, Pd, or Pt), the efficiency was greatly improved. The simultaneous loading of Pt and Pd led to a synergistic effect. It offered the highest nitrate conversion rate of ~45 mg N/h together with the N2 selectivity of ~89%. Such a high activity remained steady after 5 cycles. The optimal apparent quantum yield at 380 nm was 15.46%. More importantly, with the assistance of the surface plasma resonance effect of Au, the visible light activity achieved 1.352 mg N/h under full arc Xe-lamp, and 0.452 mg N/h under pure visible light (λ > 400 nm). Comparing to the previous achievements in photocatalytic nitrate removal, our work on ZnCr2S4 eliminates the over-reduction problem, and possesses an extremely high and steady activity under UV-light, as well as a decent conversion rate under pure visible light.

  2. ZnCr2S4: Highly effective photocatalyst converting nitrate into N2 without over-reduction under both UV and pure visible light

    Science.gov (United States)

    Yue, Mufei; Wang, Rong; Cheng, Nana; Cong, Rihong; Gao, Wenliang; Yang, Tao

    2016-08-01

    We propose several superiorities of applying some particular metal sulfides to the photocatalytic nitrate reduction in aqueous solution, including the high density of photogenerated excitons, high N2 selectivity (without over-reduction to ammonia). Indeed, ZnCr2S4 behaved as a highly efficient photocatalyst, and with the assistance of 1 wt% cocatalysts (RuOx, Ag, Au, Pd, or Pt), the efficiency was greatly improved. The simultaneous loading of Pt and Pd led to a synergistic effect. It offered the highest nitrate conversion rate of ~45 mg N/h together with the N2 selectivity of ~89%. Such a high activity remained steady after 5 cycles. The optimal apparent quantum yield at 380 nm was 15.46%. More importantly, with the assistance of the surface plasma resonance effect of Au, the visible light activity achieved 1.352 mg N/h under full arc Xe-lamp, and 0.452 mg N/h under pure visible light (λ > 400 nm). Comparing to the previous achievements in photocatalytic nitrate removal, our work on ZnCr2S4 eliminates the over-reduction problem, and possesses an extremely high and steady activity under UV-light, as well as a decent conversion rate under pure visible light.

  3. Synthesis of S/Cr doped mesoporous TiO2 with high-active visible light degradation property via solid state reaction route

    International Nuclear Information System (INIS)

    Liu Shaoyou; Tang Qunli; Feng Qingge

    2011-01-01

    S/Cr doped mesoporous TiO 2 (S-TiO 2 , Cr-TiO 2 , S-Cr-TiO 2 ) were successfully synthesized via a simple, effective and environmental benign solid state reaction route. The low angle XRD patterns demonstrated that the resulting samples possess mesostructures. The further characterizations via N 2 adsorption-desorption and XPS showed that the typical S/Cr co-doped mesoporous TiO 2 (S-Cr-TiO 2 (5S-5Cr)) possesses mesopore with the high specific surface area of 118.4 m 2 /g and narrow pore size distribution, and both S and Cr have been incorporated into the lattice of TiO 2 with the amounts of 4.16% sulfur and 7.88% chromium, respectively. And Raman spectroscopy shows that the surface of S-Cr-TiO 2 (5S-5Cr) material possesses stretching vibrational peaks at ∼709, ∼793 cm -1 are assignable to the Ti-O-Cr, O-Cr (Ti)-OH bonds, respectively. Interestingly, the UV-vis displayed that the absorption regions of S/Cr doped mesoporous TiO 2 cover the visible light region. As for the series of S-Cr-TiO 2 samples, the absorption region even extends to near infrared region with strong adsorption. Moreover, compared with the pure titanium dioxide (P25-TiO 2 ), the photodegradation properties of bromocresol green (BCG) on the S/Cr doped mesoporous TiO 2 showed excellent photocatalytic properties under visible light irradiation. Within 50 min visible light irradiation, 82.6% of the initial BCG was degraded for the S-Cr-TiO 2 (6S-4Cr) photocatalyst.

  4. Multiwall carbon nanotubes decorated with FeCr{sub 2}O{sub 4}, a new selective electrochemical sensor for amoxicillin determination

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali Asghar, E-mail: Ensafi@cc.iut.ac.ir; Allafchian, Ali Reza; Rezaei, Behzad [Isfahan University of Technology, Department of Chemistry (Iran, Islamic Republic of)

    2012-11-15

    FeCr{sub 2}O{sub 4} nanoparticles were synthesized and then multiwall carbon nanotubes (MWCNTs) were decorated with FeCr{sub 2}O{sub 4} nanoparticles. The new nanoparticles were characterized with different techniques such as vibrating sample magnetometer, Fourier transform infrared spectroscopy, scanning surface microscopy, transmission electron microscopy (TEM), atomic force microscopy (AFM), and electrochemical impedance spectroscopy. The results of the study confirm that the particles are pure FeCr{sub 2}O{sub 4}-MWCNTs with a cubic structure. No diffraction peaks of other impurities such as FeO or Cr{sub 2}O{sub 3} were observed. The diffractive peaks of FeCr{sub 2}O{sub 4}-MWCNTs are broadened, implying that the crystalline size of FeCr{sub 2}O{sub 4}-MWCNTs particles is quite small. The mean particle size of FeCr{sub 2}O{sub 4}-MWCNTs calculated by Scherrer equation is about 25 nm, whereas the existence of particles with less than 30 nm size at FeCr{sub 2}O{sub 4}-MWCNTs is clearly reflected in 2D and 3D AFM images. The TEM image confirms that the spaghetti-like FeCr{sub 2}O{sub 4}-MWCNTs formed a porous structure. The synthesized FeCr{sub 2}O{sub 4}-MWCNTs nanoparticles could be used as a new electrocatalysis for voltammetric determination of amoxicillin (AMC). Under the optimized conditions at pH 7.5 and in differential pulse voltammetry, the oxidation peak current of AMC at the surface of the mediator has two linear dynamic ranges including 0.1-10.0 and 10.0-70.0 {mu}mol L{sup -1}. The detection limit of 0.05 {mu}mol L{sup -1} was achieved. The influence of potential interfering compounds on the selectivity was studied. Finally, the modified electrode showed good sensitivity, selectivity, and stability for the determination of AMC in real samples.

  5. High-Temperature Corrosion of AlCrSiN Film in Ar-1%SO2 Gas

    Directory of Open Access Journals (Sweden)

    Poonam Yadav

    2017-03-01

    Full Text Available AlCrSiN film with a composition of 29.1Al-17.1Cr-2.1Si-51.7N in at. % was deposited on a steel substrate by cathodic arc ion plating at a thickness of 1.8 μm. It consisted of nanocrystalline hcp-AlN and fcc-CrN, where a small amount of Si was dissolved. Corrosion tests were carried out at 800 °C for 5–200 h in Ar-1%SO2 gas. The major corrosion reaction was oxidation owing to the high oxygen affinity of Al and Cr in the film. The formed oxide scale consisted primarily of (Al,Cr2O3, within which Fe, Si, and S were dissolved. Even after corrosion for 200 h, the thickness of the scale was about 0.7–1.2 μm, indicating that the film had good corrosion resistance in the SO2-containing atmosphere.

  6. Synthesis, macroscopic and local probe characterization of AgCrO$_2$ and CdCr$_2$S$_4$

    CERN Document Server

    Oliveira, Gonçalo; Araujo, J P

    The search of new materials with new and/or enhanced physical properties has, nowadays, a strict relation with the evolution of technology. The hunt for systems exhibiting simultaneous (anti)ferroelectric and (anti)ferromagnetic orders has re-started in the last years, and remains as one of the hot topics for Physic, Chemistry and Materials Science scientific communities. This is triggered by the possibility to apply these materials into, ${e.g.}$, new multiferroic memories that could be written electrically and read magnetically (or vice-versa). This thesis presents an experimental study on two of these so-called multiferroic materials, the AgCrO$_2$ delafossite and CdCr$_2$S$_4$ spinel type compounds. Different methods have been tested for the synthesis of delafossite silver chromium oxide AgCrO$_2$ namely, solid state reaction (ssr) and sol-gel combustion. The processes were optimized regarding complexing/combusting agents, temperature and duration of the heat treatments, as well as the processing atmosphe...

  7. Visible light CrO{sub 4}{sup 2-} reduction using the new CuAlO{sub 2}/CdS hetero-system

    Energy Technology Data Exchange (ETDEWEB)

    Brahimi, R. [Centre of Research in Physical and Chemical Analysis (CRAPC), BP 248, RP 16004 Algiers (Algeria); Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry (USTHB), BP 32 16111 Algiers (Algeria); Bessekhouad, Y. [Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry (USTHB), BP 32 16111 Algiers (Algeria); National Veterinary High School, BP 16111 Algiers (Algeria); Nasrallah, N. [Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry (USTHB), BP 32 16111 Algiers (Algeria); Trari, M., E-mail: solarchemistry@gmail.com [Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry (USTHB), BP 32 16111 Algiers (Algeria)

    2012-06-15

    Graphical abstract: Pseudo-first order kinetic for CrO{sub 4}{sup 2-} photoreduction for various concentrations. Highlights: Black-Right-Pointing-Pointer The work deals with the chromium reduction over CuAlO{sub 2}/CdS hetero-system. Black-Right-Pointing-Pointer The conduction band of CdS (-1.08 V) is more negative than the CrO{sub 4}{sup 2-}/Cr{sup 3+} level. Black-Right-Pointing-Pointer The sensitizer CuAlO{sub 2} has been synthesized by sol-gel. Black-Right-Pointing-Pointer The Cr(VI) reduction follows a pseudo first order kinetic with of salicylic acid. - Abstract: In this study, 64% of hexavalent chromium Cr(VI) reduction from the initial concentration (10{sup -4} M) is reported under visible light using the (CuAlO{sub 2}/CdS) hetero-system. In this new hetero-system, low doped CuAlO{sub 2} delafossite, synthesized by sol-gel works as an electrons reservoir with a wide space charge region (440 nm). In this case, the electron transfer to chromate is mediated via the hexagonal CdS variety, whose conduction band level is at -1.08 V with respect to the saturated calomel electrode which is more negative than the CrO{sub 4}{sup 2-}/Cr{sup 3+} level. This high reduction rate is achieved under optimized pH and CuAlO{sub 2} percentage. Moreover, salicylic acid gives the best performance among hole scavengers and CuAlO{sub 2} approaches 100% photostability at pH 7.5. The photo-catalytic process follows a pseudo first order kinetic with a half life of 2 h. The reaction products are identified by UV-visible spectrophotometry and linear voltametry at a platinum rotating electrode. The results reveal the presence of Cr{sup 3+} after irradiation.

  8. Ba 3 (Cr 0.97(1) Te 0.03(1) ) 2 TeO 9 : in Search of Jahn–Teller Distorted Cr(II) Oxide

    Energy Technology Data Exchange (ETDEWEB)

    Li, Man-Rong; Deng, Zheng; Lapidus, Saul H.; Stephens, Peter W.; Segre, Carlo U.; Croft, Mark; Paria Sena, Robert; Hadermann, Joke; Walker, David; Greenblatt, Martha

    2016-10-17

    A novel 6H - type hexagonal perovskite Ba 3 (Cr 0.97(1) Te 0.03 (1 ) ) 2 TeO 9 was prepared at high pressure (6 GPa) and temperature ( 1 773 K). Both transmission electron microscopy and synchrotron powder x - ray diffraction data demonstrate that Ba 3 (Cr 0.97(1) Te 0.03(1) ) 2 TeO 9 crystallize s in P6 3 / mmc with face - shared (Cr 0.97(1) Te 0.03(1) )O 6 octahedral pairs interconnected with TeO 6 octahedra via corner - sharing. Structure analysis shows a mixed Cr 2+ /Cr 3+ valence state with ~ 10% Cr 2+ . The existence of Cr 2+ in Ba 3 (Cr 2+ 0.10(1) Cr 3+ 0.87(1) Te 6+ 0.03 ) 2 TeO 9 is further evidenced by x - ray absorption near edge spectr oscopy . Magnetic properties measurements show a paramagnetic response down to 4 K and a small glassy - state curvature at low temperature. In this work, the o ctahedral Cr 2+ O 6 component is stabilized in an oxide material for the first time ; the expected Jahn - Teller distortion of high - spin ( d 4 ) Cr 2+ is not found , which is attributed to the small proportion of Cr 2+ (~ 10%) and the face - sharing arrangement of CrO 6 octahedral pairs, that structu rally dis favor axial distortion.

  9. Radiation Dose Effects into LCO in Technical Specification by Iodine in Hanul units 1,2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hye Min; Lee, Seung Chan [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This study estimates the impact of the 1-th coolant system in NPP to the LCO (Limiting Condition of Operation) limits which is in the site boundary. Dose limit is merged into the effective dose from whole body and thyroid dose limits, that is possible to combine the two LCOs to a unified LCO. To estimate the limits, the radiation dose of one of the designed accidents should be chosen to check the radiation dose response. The selected accident is based on Seung Chan Lee's study at KHNP in 2011. Using the selected accident, Iodine dose effect is reviewed depending on the LCO limiting responsibility and the specific behavior. In order to evaluate the radiation dose effect in Technical Specification of Hanul 1,2, SGTR is selected for some sensitivity analysis. From the results, in Hanul site, the case of LOOP plus ADV plus GIS is the most severe case and the dose limit margin is about 110% in LCO.

  10. On the excitation spectra of Cr{sup 3+}/Cr{sup 2+} and V{sup 3+} co-doped ZnAl{sub 2}S{sub 4} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anghel, S., E-mail: anggell@gmail.com [Institute of Applied Physics, Academiei Str 5, Chis,inău MD-2028, Republic of Moldova (Moldova, Republic of); Ruhr-Universität Bochum, Anorganische Chemie III, Universitätsstrasse 150, D-44801 Bochum (Germany); Brik, M.G. [College of Sciences, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Institute of Physics, University of Tartu, Ravila 14 C, Tartu 50411 (Estonia); Institute of Physics, Jan Dlugosz University, Armii Krajowej 13/15, PL-42200 Czestochowa (Poland); Institute of Physics, Polish Academy of Sciences, Aleja Lotników 32/46, 02-668 Warsaw (Poland); Ma, C.-G. [College of Sciences, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Sushkevich, K. [State University of Moldova, Mateevici Str 60, Chis,inău MD-2009, Republic of Moldova (Moldova, Republic of); Kulyuk, L. [Institute of Applied Physics, Academiei Str 5, Chis,inău MD-2028, Republic of Moldova (Moldova, Republic of)

    2015-10-15

    The excitation spectra of the ZnAl{sub 2}S{sub 4} spinel crystals codoped with chromium and vanadium are investigated in order to explain some features of the Cr{sup 3+} ions optical spectra and the inconsistency of the experimental absorption/emission bands position with the Tanabe–Sugano diagram, as well as the “missing” band in the absorption spectrum of V{sup 3+} ion although this band should be present as it is due to a spin allowed transition. The unusual high Racah parameters of the C/B ratio for Cr{sup 3+} ions have been induced to recalculate the Tanabe–Sugano diagram for the d{sup 3} electron configuration and the ratio C/B=8 in order to use it for the experimental results interpretation. The presence of Cr{sup 2+} ions in the low spin electron configurations in the octahedral coordination was confirmed; the temperature dependence of the Cr{sup 2+} emission at about 1.9 eV was studied and the Huang–Rhys factors were estimated for different temperatures. Despite the fact that the V{sup 3+}C/B ratio has a different value compared to the case of Cr{sup 3+} ions, the electron–phonon interaction is similar for both ions, with the Huang–Rhys parameter equal to 10 in both cases. Further research into optimizing the ZnAl{sub 2}S{sub 4}:Cr, V system to get an efficient enhancement of the vanadium emission on account on re-absorbing the chromium emission is suggested. - Highlights: • The spectroscopic properties of Cr and V codoped α-ZnAI{sub 2}S{sub 4} have been investigated. • The crystal field calculations have been performed. • The Huang–Rhys factors have been estimated for different temperatures. • The theoretical calculations have been correlated with the excitation spectra.

  11. Transition Metal Complexes of Cr, Mo, W and Mn Containing η1(S)-2,5-Dimethylthiophene, Benzothiophene and Dibenzothiophene Ligands

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, Michael [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    The UV photolysis of hexanes solutions containing the complexes M(CO)6 (M=Cr, Mo, W) or CpMn(CO)3 (Cp=η5-C5H5) and excess thiophene (T*) (T*=2,5-dimethylthiophene (2,5-Me2T), benzothiophene (BT), and dibenzothiophene (DBT)) produces the η1(S)-T* complexes (CO)5M(η1(S)-T*) 1-8 or Cp(CO)2Mn(η1(S)-T*)9-11, respectively. However, when T*=DBT, and M=Mo, a mixture of two products result which includes the η1(S)-DBT complex (CO)5Mo(η1(S)-DBT) 4a and the unexpected π-complex (CO)3Mo(η{sup 6}-DBT) 4b as detected by 1H NMR. The liability of the η1(S)-T* ligands is illustrated by the rapid displacement of DBT in the complex (CO)5W(η1(S)-DBT) (1) by THF, and also in the complexes (CO)5Cr1(S)-DBT) (5) and CpMn(CO)21(S)-DBT) (9) by CO (1 atm) at room temperature. Complexes 1-11 have been characterized spectroscopically (1H NMR, IR) and when possible isolated as analytically pure solids (elemental analysis, EIMS). Single crystal, X-ray structural determinations are reported for (Cη)5W(η1(S)-DBT) and Cp(CO)2Mn(η1(S)-DBT).

  12. Porous CrN thin films by selectively etching CrCuN for symmetric supercapacitors

    KAUST Repository

    Wei, Binbin

    2018-03-18

    Transition metal nitrides are regarded as a new class of excellent electrode materials for high-performance supercapacitors due to their superior chemical stability and excellent electrical conductivity. We synthesize successfully the porous CrN thin films for binder-free supercapacitor electrodes by reactive magnetron co-sputtering and selective chemical etching. The porous CrN thin film electrodes exhibit high-capacitance performance (31.3 mF cm−2 at 1.0 mA cm−2) and reasonable cycling stability (94% retention after 20000 cycles). Moreover, the specific capacitance is more than two-fold higher than that of the CrN thin film electrodes in previous work. In addition, a symmetric supercapacitor device with a maximum energy density of 14.4 mWh cm−3 and a maximum power density of 6.6 W cm−3 is achieved. These findings demonstrate that the porous CrN thin films will have potential applications in supercapacitors.

  13. Porous CrN thin films by selectively etching CrCuN for symmetric supercapacitors

    Science.gov (United States)

    Wei, Binbin; Mei, Gui; Liang, Hanfeng; Qi, Zhengbing; Zhang, Dongfang; Shen, Hao; Wang, Zhoucheng

    2018-05-01

    Transition metal nitrides are regarded as a new class of excellent electrode materials for high-performance supercapacitors due to their superior chemical stability and excellent electrical conductivity. We synthesize successfully the porous CrN thin films for binder-free supercapacitor electrodes by reactive magnetron co-sputtering and selective chemical etching. The porous CrN thin film electrodes exhibit high-capacitance performance (31.3 mF cm-2 at 1.0 mA cm-2) and reasonable cycling stability (94% retention after 20000 cycles). Moreover, the specific capacitance is more than two-fold higher than that of the CrN thin film electrodes in previous work. In addition, a symmetric supercapacitor device with a maximum energy density of 14.4 mWh cm-3 and a maximum power density of 6.6 W cm-3 is achieved. These findings demonstrate that the porous CrN thin films will have potential applications in supercapacitors.

  14. Substituted 7-amino-5-thio-thiazolo[4,5-d]pyrimidines as potent and selective antagonists of the fractalkine receptor (CX3CR1).

    Science.gov (United States)

    Karlström, Sofia; Nordvall, Gunnar; Sohn, Daniel; Hettman, Andreas; Turek, Dominika; Åhlin, Kristofer; Kers, Annika; Claesson, Martina; Slivo, Can; Lo-Alfredsson, Yvonne; Petersson, Carl; Bessidskaia, Galina; Svensson, Per H; Rein, Tobias; Jerning, Eva; Malmberg, Åsa; Ahlgen, Charlotte; Ray, Colin; Vares, Lauri; Ivanov, Vladimir; Johansson, Rolf

    2013-04-25

    We have developed two parallel series, A and B, of CX3CR1 antagonists for the treatment of multiple sclerosis. By modifying the substituents on the 7-amino-5-thio-thiazolo[4,5-d]pyrimidine core structure, we were able to achieve compounds with high selectivity for CX3CR1 over the closely related CXCR2 receptor. The structure-activity relationships showed that a leucinol moiety attached to the core-structure in the 7-position together with α-methyl branched benzyl derivatives in the 5-position displayed promising affinity, and selectivity as well as physicochemical properties, as exemplified by compounds 18a and 24h. We show the preparation of the first potent and selective orally available CX3CR1 antagonists.

  15. Intestinal permeability to (/sup 51/Cr)EDTA in children with Crohn's disease and celiac disease

    Energy Technology Data Exchange (ETDEWEB)

    Turck, D.; Ythier, H.; Maquet, E.; Deveaux, M.; Marchandise, X.; Farriaux, J.P.; Fontaine, G.

    1987-07-01

    (/sup 51/Cr)EDTA was used as a probe molecule to assess intestinal permeability in 7 healthy control adults, 11 control children, 17 children with Crohn's disease, and 6 children with untreated celiac disease. After subjects fasted overnight, 75 kBq/kg (= 2 microCi/kg) /sup 51/Cr-labeled EDTA was given by mouth; 24-h urinary excretion of (/sup 51/Cr)EDTA was measured and expressed as a percentage of the total oral dose. Mean and SD were as follows: control adults 1.47 +/- 0.62, control children 1.59 +/- 0.55, and patients with Crohn's disease or celiac disease 5.35 +/- 1.94. The difference between control children and patients was statistically significant (p less than 0.001). These results show that intestinal permeability to (/sup 51/Cr)EDTA is increased among children with active or inactive Crohn's disease affecting small bowel only or small bowel and colon, and with untreated celiac disease. The (/sup 51/Cr)EDTA permeability test could facilitate the decision to perform more extensive investigations in children suspected of small bowel disease who have atypical or poor clinical and biological symptomatology.

  16. Structure and microstructure of the high pressure synthesised misfit layer compound [Sr2O2][CrO2]1.85

    International Nuclear Information System (INIS)

    Castillo-Martinez, E.; Schoenleber, A.; Smaalen, S. van; Arevalo-Lopez, A.M.; Alario-Franco, M.A.

    2008-01-01

    The strontium chromium oxide [Sr 2 O 2 ][CrO 2 ] 1.85 misfit layer compound has been synthesised at high-pressure and high-temperature conditions. Electron diffraction patterns and high-resolution transmission electron microscopy images along [001] show the misfit character of the different layers composing the structure with a supercell along the incommensurate parameter b∼7b 1 ∼13b 2 . The modulated crystal structure has been refined within the superspace formalism against single-crystal X-ray diffraction data, employing the (3+1)-dimensional superspace group C'nmb(0σ 2 0)0 0 s. The compound has a composite structure with lattice parameters a 1 =5.182(1) A, b 1 =5.411(1) A, c 1 =18.194(3) A for the first, SrO, subsystem and the same a and c, but with b 2 =2.925(1) A for the second, CrO 2 , subsystem. The layer stacking is similar to that of orthorhombic PbS(TiS 2 ) 1.18 , but with a much stronger intersubsytem bonding in the case of the oxide. The intersubsystem lattice mismatch is mainly handled by displacement modulations of the Sr atoms, correlated with modulations of the valence, the coordination and the anisotropic displacement parameters. - Graphical abstract: A strontium chromium oxide, [Sr 2 O 2 ][CrO 2 ] 1.85 , with an orthorhombic misfit layer structure has been synthesised under high pressure. Mainly modulations on the Sr position, ADPs and coordination save the subsystems lattice mismatch

  17. Threshold oxygen levels in Na(I) for the formation of NaCrO 2(s) on 18-8 stainless steels from accurate thermodynamic measurements

    Science.gov (United States)

    Sreedharan, O. M.; Madan, B. S.; Gnanamoorthy, J. B.

    1983-12-01

    The compound NaCrO 2(s) is an important corrosion product in sodium-cooled LMFBRs. The standard Gibbs energy of formation of NaCrO 2(s) is required for the computation of threshold oxygen levels in Na(1) for the formation of NaCrO 2(s) on 18-8 stainless steels. For this purpose the emf of the galvanic cell: Pt, NaCrO 2, Cr 2O 3, Na 2CrO 4/15 YSZ/O 2 ( P O 2 = 0.21 atm, air), Pt was measured over 784-1012 K to be: (E±4.4)(mV) = 483.67-0.34155 T(K). From this, the standard Gibbs energy of formation of NaCrO 2(s) from the elements ( ΔG f,T0) and from the oxides ( ΔG f,OX,T0) was calculated to be: [ΔG f,T0(NaCrO 2, s1.86] (kJ/mol) =-869.98 + 0.18575 T(K) , [ΔG f,OX,T0(NaCr0 2, s)±4.8] (kJ/mol) = -104.25-0.00856 T(K) . The molar heat capacity, C P0, of NaCrO 2(s) was measured by DSC to be (350-600 K): C P0(NaCrO 2, s) (J/K mol) = 27.15 + 0.1247 T (K) , From these data, values of -99.3 kJ/mol and 91.6 J/K mol were computed for ΔH f,2980 and S 2980 of NaCrO 2(s). The internal consistency was checked with the use of enthalpy data on Na 2CrO 4(s). From the standard Gibbs energy of formation of NaCrO 2(s) the equation logC 0(wppm) = 3.9905-3147.6 T(K) was derived, where C 0 is the threshold oxygen level for the formation of NaCrO 2(s) on 18-8 stainless steels.

  18. Structural, magnetic, and dielectric properties of multiferroic Co1−xMgxCr2O4 nanoparticles

    International Nuclear Information System (INIS)

    Kamran, M.; Ullah, A.; Rahman, S.; Tahir, A.; Nadeem, K.; Anis ur Rehman, M.; Hussain, S.

    2017-01-01

    Highlights: • Properties of multiferroic Co 1−x Mg x Cr 2 O 4 nanoparticles have been studied. • XRD showed that CoCr 2 O 4 and MgCr 2 O 4 are cubic normal spinel structure. • Rietveld refinement of XRD showed no impurity phases. • T c and T s showed decreasing trend with increasing Mg concentration. • Dielectric properties were improved for x = 0.6 Mg concentration. - Abstract: We examined the structural, magnetic, and dielectric properties of Co 1−x Mg x Cr 2 O 4 nanoparticles with composition x = 0, 0.2, 0.4, 0.5, 0.6, 0.8 and 1 in detail. X-ray diffraction (XRD) revealed normal spinel structure for all the samples. Rietveld refinement fitting results of the XRD showed no impurity phases which signifies the formation of single phase Co 1−x Mg x Cr 2 O 4 nanoparticles. The average crystallite size showed a peak behaviour with maxima at x = 0.6. Raman and Fourier transform infrared (FTIR) spectroscopy also confirmed the formation of single phase normal spinel for all the samples and exhibited dominant vibrational changes for x ≥ 0.6. For x = 0 (CoCr 2 O 4 ), zero field cooled/field cooled (ZFC/FC) magnetization curves showed paramagnetic (PM) to ferrimagnetic (FiM) transition at T c = 97 K and a conical spiral magnetic order at T s = 30 K. The end members CoCr 2 O 4 (x = 0) and MgCr 2 O 4 (x = 1) are FiM and antiferromagnetic (AFM), respectively. T c and T s showed decreasing trend with increasing x, followed by an additional AFM transition at T N = 15 K for x = 0.6. The system finally stabilized and changed to highly frustrated AFM structure at x = 1 due to formation of pure MgCr 2 O 4 . High field FC curves (5T) depicted nearly no effect on spiral magnetic state, which is attributed to strong exchange B-B magnetic interactions at low temperatures. Dielectric parameters showed a non-monotonous behaviour with Mg concentration and were explained with the help of Maxwell-Wagner model and Koop’s theory. Dielectric properties were improved for

  19. A simple Cr(VI)–S(IV)–O{sub 2} system for rapid and simultaneous reduction of Cr(VI) and oxidative degradation of organic pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yanan; Yang, Shaojie [Department of Environmental Science, Hubei Key Lab of Biomass Resource Chemistry and Environmental Biotechnology, School of Resources and Environmental Science, Wuhan University, 430079 (China); Zhou, Danna, E-mail: zdncug@163.com [Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan 430074 (China); Wu, Feng [Department of Environmental Science, Hubei Key Lab of Biomass Resource Chemistry and Environmental Biotechnology, School of Resources and Environmental Science, Wuhan University, 430079 (China)

    2016-04-15

    Highlights: • Rapid and simultaneous reduction of Cr(VI) and degradation of organic pollutants occur. • Oxysulfur radicals generated in Cr(VI)–S(IV)–O{sub 2} system oxidize the organic pollutants. • Acidic pH facilitates the reactions from both directions of reduction and oxidation. • Degradation potential of aromatic amines depends on the substituted groups. • Cr(VI)–S(IV)–O{sub 2} system is promising for “waste control by waste”. - Abstract: Hexavalent chromium (Cr(VI)), a heavy-metal contaminant, can be easily reduced to less toxic trivalent chromium (Cr(III)) by sulfite ions (S(IV)). However, S(IV) has not drawn as much attention as the ferrous ion has. We report herein a novel Cr(VI)–S(IV)–O{sub 2} system containing sulfite ions that rapidly and simultaneously reduces Cr(VI) and oxidize organic pollutants in the presence of oxygen in aqueous solutions. This Cr(VI)–S(IV)-O{sub 2} system contains the initiator Cr(VI), the reductant S(IV), and the oxidant O{sub 2}, which produce oxysulfur radicals (mainly SO{sub 4}·{sup −} and SO{sub 5}·{sup −}) and hydroxyl radicals (OH·). The Cr(VI)/S(IV) molar ratio, pH, and oxygen content play important roles in the entire reaction system. Acidic conditions (pH 3.0) facilitated degradation of organic compounds and reduction of Cr(VI) as well. In addition, experiments of rapid degradation of several kinds of organic pollutants such as azo dye (acid orange 7, AO7), aniline, phenol, bisphenol A etc were also conducted. Preliminary results show that the removal rates of the analogs of phenols or aromatic amines in this Cr(VI)–S(IV)–O{sub 2} system have a relationship with the electronic parameters (Hammett constant, σ) of the substituted groups. Thus, the Cr(VI)–S(IV)–O{sub 2} system, provides an excellent strategy of “waste control by waste” for removing multiple industrial contaminants.

  20. Effect of niobium on the embrittlement of 2.25 Cr and 2.25 Cr-1Mo steels by phosphous

    International Nuclear Information System (INIS)

    Antunes, J.L.B.

    1985-01-01

    The influence of niobium on the temper embrittlement of 2.25Cr and 2.25 Cr-1Mo steels doped with phosphorus is evaluated. The transition temperatures of the samples tempered at 650 0 C and aged at different temperatures for niobium steels. (M.J.C.) [pt

  1. The effect of microstructure and temperature on the oxidation behavior of two-phase Cr-Cr2X (X=Nb,Ta) alloys

    International Nuclear Information System (INIS)

    Brady, M.P.; Tortorelli, P.F.

    1998-01-01

    The oxidation behavior of Cr(X) solid solution (Cr ss ) and Cr 2 X Laves phases (X = Nb, Ta) was studied individually and in combination at 950--1,100 C in air. The Cr ss phase was significantly more oxidation resistant than the Cr 2 X Laves phase. At 950 C, two-phase alloys of Cr-Cr 2 Nb and Cr-Cr 2 Ta exhibited in-situ internal oxidation, in which remnants of the Cr 2 X Laves phase were incorporated into a growing chromia scale. At 1,100 C, the Cr-Cr 2 Nb alloys continued to exhibit in-situ internal oxidation, which resulted in extensive O/N penetration into the alloy ahead of the alloy-scale interface and catastrophic failure during cyclic oxidation. IN contrast, the Cr-Cr 2 Ta alloys exhibited a transition to selective Cr oxidation and the formation of a continuous chromia scale. The oxidation mechanism is interpreted in terms of multiphase oxidation theory

  2. Gas treatment of Cr(VI)-contaminated sediment samples from the North 60's pits of the chemical waste landfill

    International Nuclear Information System (INIS)

    Thornton, E.C.; Amonette, J.E.

    1997-12-01

    Twenty sediment samples were collected at depths ranging from 5 to 100 ft (1.5 to 30 m) beneath a metal-contaminated plating-waste site and extensively characterized for Cr(VI) content and environmental availability. Three samples were selected for treatment with diluted gas mixtures with the objective of converting Cr(VI) to Cr(III), which is relatively nontoxic and immobile. These tests were designed to provide information needed to evaluate the potential application of gas injection as an in situ remediation technique. Gas treatment was performed in small columns (4.9-cm ID, 6.4- to 13.9-cm long) using 100 ppm (μL L -1 ) H 2 S or ethylene mixtures in N 2 . Treatment progress during the tests involving H 2 S was assessed by monitoring the breakthrough of H 2 S. Evaluation of H 2 S treatment efficacy included (1) water-leaching of treated and untreated columns for ten days, (2) repetitive extraction of treated and untreated subsamples by water, 0.01 M phosphate (pH 7) or 6 M HCl solutions, and (3) Cr K-edge X-ray absorption near-edge structure (XANES) spectroscopy of treated and untreated subsamples. Results of the water-leaching studies showed that the H 2 S treatment decreased Cr(VI) levels in the column effluent by 90% to nearly 100%. Repetitive extractions by water and phosphate solutions echoed these results, and the extraction by HCl released only 35-40% as much Cr in the treated as in the untreated samples. Analysis by XANES spectroscopy showed that a substantial portion of the Cr in the samples remained as Cr(VI) after treatment, even though it was not available to the water and phosphate extracting solutions. These results suggest that this residual Cr(VI) is present in low solubility phases such as PbCrO 4 or sequestered in unreacted grain interiors under impermeable coatings formed during H 2 S treatment. However, this fraction is essentially immobile and thus unavailable to the environment

  3. Creep Rupture Analysis and Life Estimation of 1.25Cr-0.5Mo, 2.25Cr-1Mo and Modified 9Cr-1Mo Steel: A Comparative Study

    Science.gov (United States)

    Roy, Prabir Kumar

    2018-04-01

    This paper highlights a comparative assessment of creep life of 1.25Cr-0.5Mo, 2.25Cr-1Mo and modified 9Cr-1Mo steels based on accelerated creep rupture tests. Creep rupture test data have been analysed and creep life of the above mentioned materials have been assessed using Larson Miller parameter at the stress levels of 60 and 42 MPa for different temperatures. Limiting steam temperatures for minimum design life of 105 h at 42 and 60 MPa for the above mentioned steels have also been calculated. Microstructural studies for the three above mentioned steels are also done.

  4. Dose distribution perturbation due to a Co-Cr-Mo prosthesis

    International Nuclear Information System (INIS)

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-01-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  5. Dose-equivalent response CR-39 track detector for personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Oda, K.; Ito, M.; Yoneda, H.; Miyake, H.; Yamamoto, J.; Tsuruta, T.

    1991-01-01

    A dose-equivalent response detector based on CR-39 has been designed to be applied for personnel neutron dosimetry. The intrinsic detection efficiency of bare CR-39 was first evaluated from irradiation experiments with monoenergetic neutrons and theoretical calculations. In the second step, the radiator effect was investigated for the purpose of sensitization to fast neutrons. A two-layer radiator consisting of deuterized dotriacontane (C 32 D 66 ) and polyethylene (CH 2 ) was designed. Finally, we made the CR-39 detector sensitive to thermal neutrons by doping with orthocarbone (B 10 H 12 C 2 ), and also estimated the contribution of albedo neutrons. It was found that the new detector - boron-doped CR-39 with the two-layer radiator - would have a flat response with an error of about 70% in a wide energy region, ranging from thermal to 15 MeV. (orig.)

  6. High strain rate tensile properties of annealed 2 1/4 Cr--1 Mo steel

    International Nuclear Information System (INIS)

    Klueh, R.L.; Oakes, R.E. Jr.

    1975-01-01

    The high strain rate tensile properties of annealed 2 1 / 4 Cr-1 Mo steel were determined and the tensile behavior from 25 to 566 0 C and strain rates of 2.67 x 10 -6 to 144/s were described. Above 0.1/s at 25 0 C, both the yield stress and the ultimate tensile strength increased rapidly with increasing strain rate. As the temperature was increased, a dynamic strain aging peak appeared in the ultimate tensile strength-temperature curves. The peak height was a maximum at about 350 0 C and 2.67 x 10 -6 /s. With increasing strain rate, a peak of decreased height occurred at progressively higher temperatures. The major effect of strain rate on ductility occurred at elevated temperatures, where a decrease in strain rate caused an increase in total elongation and reduction in area

  7. Magnetic and electrical properties of In doped FeCr{sub 2}S{sub 4} compound

    Energy Technology Data Exchange (ETDEWEB)

    Sagredo, V. [Lab. de Magnetismo, Facultad de Ciencias, Universidad de los Andes, Merida, 5101 (Venezuela)], E-mail: sagredo@ula.ve; Davila, Y. [Lab. de Magnetismo, Facultad de Ciencias, Universidad de los Andes, Merida, 5101 (Venezuela); Goya, G.F. [Instituto Universitario de Investigacion en Nanociencia de Aragon, Zaragoza (Spain)

    2008-07-15

    Single crystals of FeIn{sub 1-x}Cr{sub 2x}S{sub 4} compounds have been grown by using the chemical transport method. DC magnetization measurements on single crystals for 0.6{<=}x{<=}1.0 revealed a reentrant behavior below T{sub sg}=120-170 K depending on the Cr concentration sample. The transition temperature T{sub c} increases as the indium concentration increases. The electrical resistivity measurements on polycrystalline materials above the Curie temperature revealed that the conduction behavior could be described as magnetic-polaron transport.

  8. One-pot tandem Ugi-4CR/S(N)Ar approach to highly functionalized quino[2,3-b][1,5]benzoxazepines.

    Science.gov (United States)

    Ghandi, Mehdi; Zarezadeh, Nahid; Abbasi, Alireza

    2016-05-01

    We have developed a convenient and facile method for the synthesis of functionalized diverse quino[2,3-b][1,5]benzoxazepines. These new compounds were synthesized through a one-pot sequential Ugi-4CR/base-free intramolecular aromatic nucleophilic substitution (S(N)Ar) reaction in moderate to good yields from readily available starting materials. Structural confirmation of the products is confirmed by analytical data and X-ray crystallography.

  9. Cr2O3 thin films grown at room temperature by low pressure laser chemical vapour deposition

    International Nuclear Information System (INIS)

    Sousa, P.M.; Silvestre, A.J.; Conde, O.

    2011-01-01

    Chromia (Cr 2 O 3 ) has been extensively explored for the purpose of developing widespread industrial applications, owing to the convergence of a variety of mechanical, physical and chemical properties in one single oxide material. Various methods have been used for large area synthesis of Cr 2 O 3 films. However, for selective area growth and growth on thermally sensitive materials, laser-assisted chemical vapour deposition (LCVD) can be applied advantageously. Here we report on the growth of single layers of pure Cr 2 O 3 onto sapphire substrates at room temperature by low pressure photolytic LCVD, using UV laser radiation and Cr(CO) 6 as chromium precursor. The feasibility of the LCVD technique to access selective area deposition of chromia thin films is demonstrated. Best results were obtained for a laser fluence of 120 mJ cm -2 and a partial pressure ratio of O 2 to Cr(CO) 6 of 1.0. Samples grown with these experimental parameters are polycrystalline and their microstructure is characterised by a high density of particles whose size follows a lognormal distribution. Deposition rates of 0.1 nm s -1 and mean particle sizes of 1.85 μm were measured for these films.

  10. Cr doping induced negative transverse magnetoresistance in C d3A s2 thin films

    Science.gov (United States)

    Liu, Yanwen; Tiwari, Rajarshi; Narayan, Awadhesh; Jin, Zhao; Yuan, Xiang; Zhang, Cheng; Chen, Feng; Li, Liang; Xia, Zhengcai; Sanvito, Stefano; Zhou, Peng; Xiu, Faxian

    2018-02-01

    The magnetoresistance of a material conveys various dynamic information about charge and spin carriers, inspiring both fundamental studies in physics and practical applications such as magnetic sensors, data storage, and spintronic devices. Magnetic impurities play a crucial role in the magnetoresistance as they induce exotic states of matter such as the quantum anomalous Hall effect in topological insulators and tunable ferromagnetic phases in dilute magnetic semiconductors. However, magnetically doped topological Dirac semimetals are hitherto lacking. Here, we report a systematic study of Cr-doped C d3A s2 thin films grown by molecular-beam epitaxy. With the Cr doping, C d3A s2 thin films exhibit unexpected negative transverse magnetoresistance and strong quantum oscillations, bearing a trivial Berry's phase and an enhanced effective mass. More importantly, with ionic gating the magnetoresistance of Cr-doped C d3A s2 thin films can be drastically tuned from negative to positive, demonstrating the strong correlation between electrons and the localized spins of the Cr impurities, which we interpret through the formation of magnetic polarons. Such a negative magnetoresistance under perpendicular magnetic field and its gate tunability have not been observed previously in the Dirac semimetal C d3A s2 . The Cr-induced topological phase transition and the formation of magnetic polarons in C d3A s2 provide insights into the magnetic interaction in Dirac semimetals as well as their potential applications in spintronics.

  11. Fast photoelectro-reduction of Cr{sup VI} over MoS{sub 2}@TiO{sub 2} nanotubes on Ti wire

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lixia; Zheng, Xutong; Liu, Ming [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Shenglian, E-mail: sllou@hnu.edu.cn [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); College of Material Science and Engineering, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Yan [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); Li, Guifa [College of Material Science and Engineering, Nanchang Hangkong University, Nanchang 330063 (China)

    2017-05-05

    Highlights: • Few-layer MoS{sub 2} nanosheets decorated on the TiO{sub 2} NTAs via a facile hydrothermal method. • The composites possess a stable construction benefiting to the utilization of sunlight and electron transfer. • High concentration Cr{sup VI} can be fast reduced over MoS{sub 2}@TiO{sub 2} in the presence of appropriate LOAs and applied voltage. • Effect of LOAs, applied voltages and initial concentrations were performed. - Abstract: A stable MoS{sub 2} nanosheets@TiO{sub 2} NTAs composite was prepared via a simple hydrothermal process. Few-layer MoS{sub 2} nanosheets distributed on the TiO{sub 2} nanotube top surface and the inner walls rather than filling in the tubes, allowing abundant tubular channels open to environment and benefiting for efficient mass transport. Photocatalytic (PE) and photoelectrocatalytic (PEC) performance of the composite were evaluated on Cr{sup VI} reduction, with variable low molecule weight organic acids (LOAs) added as sacrificial electron donor to form a charge-transfer-complex (CTC) between LOAs and TiO{sub 2}/MoS{sub 2}, which is sensitive to the visible light illumination and could induce the photo-reduction of Cr{sup VI} and photo-oxidation of LOAs. The overall trend of Cr{sup VI} PEC rates are in the order as: L(+)-Tartaric acid > oxalic acid > citric acid > malic acid > amber acid, which is 103.9 > 62.5 > 31.2 > 21.6 > 2.5 mg/L min{sup −1} cm{sup −2}, respectively. The improved catalytic performance and excellent stability of the composite can be attributed to the abundant active adsorption and reaction sites on MoS{sub 2} nanosheets and the formation of a heterojunction between TiO{sub 2} and MoS{sub 2}. Moreover, the appropriate application of LOAs and voltage also have a great contribution to the utilization of sunlight and efficient separation of photogenerated carriers.

  12. Development and Application of Binary Suspensions in the Ternary System Cr2O3-TiO2-Al2O3 for S-HVOF Spraying

    Science.gov (United States)

    Potthoff, Annegret; Kratzsch, Robert; Barbosa, Maria; Kulissa, Nick; Kunze, Oliver; Toma, Filofteia-Laura

    2018-04-01

    Compositions in the system Cr2O3-TiO2-Al2O3 are among the most used ceramic materials for thermally sprayed coating solutions. Cr2O3 coatings present good sliding wear resistance; Al2O3 coatings show excellent insulation behavior and TiO2 striking corrosion properties. In order to combine these properties, coatings containing more than one oxide are highly interesting. The conventional spraying process is limited to the availability of binary feedstock powders with defined compositions. The use of suspensions offers the opportunity for tailor-made chemical compositions: within the triangle of Cr2O3-TiO2-Al2O3, each mixture of oxides can be created. Criteria for the selection of raw materials as well as the relevant aspects for the development of binary suspensions in the Cr2O3-TiO2-Al2O3 system to be used as feedstock for thermal spraying are presented. This formulation of binary suspensions required the development of water-based single-oxide suspensions with suitable behavior; otherwise, the interaction between the particles while mixing could lead up to a formation of agglomerates, which affect both the stability of the spray process and the coating properties. For the validation of this formulation procedure, binary Cr2O3-TiO2 and Al2O3-TiO2 suspensions were developed and sprayed using the S-HVOF process. The binary coatings were characterized and discussed in terms of microstructure and microhardness.

  13. Development and Application of Binary Suspensions in the Ternary System Cr2O3-TiO2-Al2O3 for S-HVOF Spraying

    Science.gov (United States)

    Potthoff, Annegret; Kratzsch, Robert; Barbosa, Maria; Kulissa, Nick; Kunze, Oliver; Toma, Filofteia-Laura

    2018-03-01

    Compositions in the system Cr2O3-TiO2-Al2O3 are among the most used ceramic materials for thermally sprayed coating solutions. Cr2O3 coatings present good sliding wear resistance; Al2O3 coatings show excellent insulation behavior and TiO2 striking corrosion properties. In order to combine these properties, coatings containing more than one oxide are highly interesting. The conventional spraying process is limited to the availability of binary feedstock powders with defined compositions. The use of suspensions offers the opportunity for tailor-made chemical compositions: within the triangle of Cr2O3-TiO2-Al2O3, each mixture of oxides can be created. Criteria for the selection of raw materials as well as the relevant aspects for the development of binary suspensions in the Cr2O3-TiO2-Al2O3 system to be used as feedstock for thermal spraying are presented. This formulation of binary suspensions required the development of water-based single-oxide suspensions with suitable behavior; otherwise, the interaction between the particles while mixing could lead up to a formation of agglomerates, which affect both the stability of the spray process and the coating properties. For the validation of this formulation procedure, binary Cr2O3-TiO2 and Al2O3-TiO2 suspensions were developed and sprayed using the S-HVOF process. The binary coatings were characterized and discussed in terms of microstructure and microhardness.

  14. Gate Tunable Transport in Graphene/MoS2/(Cr/Au Vertical Field-Effect Transistors

    Directory of Open Access Journals (Sweden)

    Ghazanfar Nazir

    2017-12-01

    Full Text Available Two-dimensional materials based vertical field-effect transistors have been widely studied due to their useful applications in industry. In the present study, we fabricate graphene/MoS2/(Cr/Au vertical transistor based on the mechanical exfoliation and dry transfer method. Since the bottom electrode was made of monolayer graphene (Gr, the electrical transport in our Gr/MoS2/(Cr/Au vertical transistors can be significantly modified by using back-gate voltage. Schottky barrier height at the interface between Gr and MoS2 can be modified by back-gate voltage and the current bias. Vertical resistance (Rvert of a Gr/MoS2/(Cr/Au transistor is compared with planar resistance (Rplanar of a conventional lateral MoS2 field-effect transistor. We have also studied electrical properties for various thicknesses of MoS2 channels in both vertical and lateral transistors. As the thickness of MoS2 increases, Rvert increases, but Rplanar decreases. The increase of Rvert in the thicker MoS2 film is attributed to the interlayer resistance in the vertical direction. However, Rplanar shows a lower value for a thicker MoS2 film because of an excess of charge carriers available in upper layers connected directly to source/drain contacts that limits the conduction through layers closed to source/drain electrodes. Hence, interlayer resistance associated with these layers contributes to planer resistance in contrast to vertical devices in which all layers contribute interlayer resistance.

  15. Improvements in the susceptibility to hydrogen attack and stress-relief cracking of 2 1/4Cr-1Mo steels

    International Nuclear Information System (INIS)

    Imanaka, T.; Sato, S.; Shimomura, J.; Aso, K.

    1985-01-01

    The influence of sulphur content at extremely low level on the susceptibility to hydrogen attack and stress-relief cracking in 2 1/4Cr-1Mo steels was studied. The reduction of sulphur content and/or the addition of REM (rare earth metal) or Ca in accordance with sulphur content remarkably improve the resistivity against hydrogen attack and stress-relief cracking. Micro-structural examination has showed that there exist Mn-REM-S-Al-O complex particles in the REM-added steels. It is concluded that the effect of REM on hydrogen attack and stress-relief cracking is to reduce ''the free sulphur'' in 2 1/4Cr-1Mo steels

  16. Expression pattern of Ccr2 and Cx3cr1 in inherited retinal degeneration.

    Science.gov (United States)

    Kohno, Hideo; Koso, Hideto; Okano, Kiichiro; Sundermeier, Thomas R; Saito, Saburo; Watanabe, Sumiko; Tsuneoka, Hiroshi; Sakai, Tsutomu

    2015-10-12

    Though accumulating evidence suggests that microglia, resident macrophages in the retina, and bone marrow-derived macrophages can cause retinal inflammation which accelerates photoreceptor cell death, the details of how these cells are activated during retinal degeneration (RD) remain uncertain. Therefore, it is important to clarify which cells play a dominant role in fueling retinal inflammation. However, distinguishing between microglia and macrophages is difficult using conventional techniques such as cell markers (e.g., Iba-1). Recently, two mouse models for visualizing chemokine receptors were established, Cx3cr1 (GFP/GFP) and Ccr2 (RFP/RFP) mice. As Cx3cr1 is expressed in microglia and Ccr2 is reportedly expressed in activated macrophages, these mice have the potential to distinguish microglia and macrophages, yielding novel information about the activation of these inflammatory cells and their individual roles in retinal inflammation. In this study, c-mer proto-oncogene tyrosine kinase (Mertk) (-/-) mice, which show photoreceptor cell death due to defective retinal pigment epithelium phagocytosis, were employed as an animal model of RD. Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice were established by breeding Mertk (-/-) , Cx3cr1 (GFP/GFP) , and Ccr2 (RFP/RFP) mice. The retinal morphology and pattern of inflammatory cell activation and invasion of Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice were evaluated using retina and retinal pigment epithelium (RPE) flat mounts, retinal sections, and flow cytometry. Four-week-old Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice showed Cx3cr1-GFP-positive microglia in the inner retina. Cx3cr1-GFP and Ccr2-RFP dual positive activated microglia were observed in the outer retina and subretinal space of 6- and 8-week-old animals. Ccr2-RFP single positive bone marrow-derived macrophages were observed to migrate into the retina of Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice. These invading cells were still observed in the

  17. Neutron investigation of Ru-doped Nd1/2Ca1/2MnO3. Comparison with Cr-doped Nd1/2Ca1/2MnO3

    International Nuclear Information System (INIS)

    Moritomo, Yutaka; Nonobe, Toshihiko; Machida, Akihiko; Ohoyama, Kenji

    2002-01-01

    Lattice and magnetic properties are investigated for 3% Ru- and Cr-doped Nd 1/2 Ca 1/2 MnO 3 . The parent Nd 1/2 Ca 1/2 MnO 3 is a charge-ordered insulator (T CO =250K). With decreasing temperature below ≅210K, these compounds are separated into two perovskite phases, that is, the long-c and short-c phases. The long-c region shows a ferromagnetic transition at T C ≅210K for the Ru-doped compound and ≅130K for the Cr-doped compound, while the short-c region shows antiferromagnetic transition at T N ≅150K for Ru and ≅110K for Cr. We discuss the origin of the enhanced T C for the Ru-doped compound in terms of the effective one-electron bandwidth W of the e g -band. (author)

  18. The electronic structure of the metastable layer compound 1T-CrSe2

    NARCIS (Netherlands)

    Fang, C.M.; Groot, R.A. de; Wiegers, G.A.; Haas, C.; vanBruggen, C.F.; deGroot, R.A.

    1997-01-01

    The electronic structure of the metastable compound 1T-CrSe2 (a = 3.399 Å, c = 5.911 Å, space group P_3m1) was calculated with and without spin polarization using the LSW method. The energy is 0.29 eV/mol CrSe2 lower for the spin-polarized calculation. The total magnetic moment of +2.44 μB on Cr

  19. Type IIIa cracking at 2CrMo welds in 1/2CrMoV pipework

    Energy Technology Data Exchange (ETDEWEB)

    Brett, S J; Smith, P A [National Power plc, Swindon (United Kingdom)

    1999-12-31

    The most common form of in-service defect found today on the welds of National Power`s 1/2CrMoV pipework systems is Type IV cracking which occurs in intercritically transformed material at the edge of the heat affected zone. However an alternate form of cracking, termed IIIa, which occurs close to the weld fusion line in fully grain refined heat affected zones, has also been observed. The incidence of Type IIIa cracking has increased in recent years and these defects now constitute a significant part of the total recorded crack population. This presentation describes Type IIIa cracking and compares and contrasts it with the better documented Type IV cracking. Particular reference is made to the role of carbon diffusion at the weld fusion line in promoting Type IIIa damage in preference to Type IV. (orig.) 5 refs.

  20. Type IIIa cracking at 2CrMo welds in 1/2CrMoV pipework

    Energy Technology Data Exchange (ETDEWEB)

    Brett, S.J.; Smith, P.A. [National Power plc, Swindon (United Kingdom)

    1998-12-31

    The most common form of in-service defect found today on the welds of National Power`s 1/2CrMoV pipework systems is Type IV cracking which occurs in intercritically transformed material at the edge of the heat affected zone. However an alternate form of cracking, termed IIIa, which occurs close to the weld fusion line in fully grain refined heat affected zones, has also been observed. The incidence of Type IIIa cracking has increased in recent years and these defects now constitute a significant part of the total recorded crack population. This presentation describes Type IIIa cracking and compares and contrasts it with the better documented Type IV cracking. Particular reference is made to the role of carbon diffusion at the weld fusion line in promoting Type IIIa damage in preference to Type IV. (orig.) 5 refs.

  1. Enthalpy-increment measurements for CsI(s) and Cs2CrO4(s) by high-temperature Calvet calorimetry

    International Nuclear Information System (INIS)

    Venugopal, V.; Agarwal, R.; Roy, K.N.; Prasad, R.; Sood, D.D.

    1987-01-01

    Molar thermodynamic properties of CsI(s) and Cs 2 Cr O 4 (s) have been evaluated by enthalpy-increment measurements, using a Calvet high-temperature calorimeter. Least squares analyses were performed on the enthalpy increment results. Data is presented in tabular form for the dependence of enthalpy increments on temperature, in the range 333 to 822 K, for both caesium compounds, along with the thermal properties of the compounds. Good agreement is found between the present data and previously reported results on reduced enthalpy increments of CsI(s) and Cs 2 CrO 4 (s). (U.K.)

  2. Population pharmacokinetics and pharmacodynamics of ponesimod, a selective S1P1 receptor modulator.

    Science.gov (United States)

    Krause, Andreas; Brossard, Patrick; D'Ambrosio, Daniele; Dingemanse, Jasper

    2014-06-01

    Ponesimod (ACT-128800), a reversible, orally active, selective S1P1 receptor modulator, prevents the egress of lymphocytes from the lymph node into the systemic circulation. It is currently in clinical development for the treatment of relapsing multiple sclerosis. Modulation of circulating lymphocytes serves as biomarker of efficacy and safety, such that the quantitative characterization of the pharmacokinetic/pharmacodynamic (PK/PD) relationship guides the clinical development of the compound. The availability of a variety of doses, dosing regimens, and treatment durations permitted estimation of the pharmacokinetics characterized by an absorption lag time followed by a sequential zero/first-order absorption and two compartments with first-order elimination. The PD are modeled as an indirect-effect model with rates of appearance and disappearance of lymphocytes in blood with a circadian rhythm and a drug effect on the rate of appearance. The model suggests a circadian variation of 9% and a maximum inhibition of 86% of total lymphocyte count with high doses at steady state. It was instrumental for the selection of doses for subsequent studies that confirmed the effect plateau in total lymphocyte count at approximately 0.5 × 10(9) counts/L.

  3. Neutral complexes as oxidants for the reduced form of parsley (Petroselinum crispum) [2Fe--2S] ferredoxin. Evidence for partial blocking by redox-inactive Cr(III) complexes.

    Science.gov (United States)

    Adzamli, I K; Kim, H O; Sykes, A G

    1982-01-01

    The 1 : 1 reactions of three neutral Co(III) oxidants, Co(acac)3, Co(NH3)3(NO2)3 and Co(acac)2(NH3)(NO2), with reduced parsley (Petroselinum crispum) [2Fe--2S] ferredoxin (which carries a substantial negative charge), have been studied at 25 degrees C, pH 8.0 (Tris/HCl), I0.10 (NaCl). Whereas it has previously been demonstrated that with Co(NH3)6+ as oxidant the reaction if completely blocked by redox-inactive Cr(NH3)63+, the neutral oxidants are only partially blocked by this same complex. The effects of three Cr(III) complexes, Cr(NH3)63+%, Cr(en)33+ and (en)2Cr . mu(OH,O2CCH3) . CR(en)24+ have been investigated. Kinetic data for the response of 3+, neutral, as well as 1--oxidants to the presence of 3+ (and 4+) Cr(III) complexes can now be rationalized in terms of a single functional site on the protein for electron transfer. Electrostatics have a significant influence on association at this site. PMID:7115307

  4. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  5. Formulation and Characterization of Cr2O3 Doped ZnO Thick Films as H2S Gas Sensor

    Directory of Open Access Journals (Sweden)

    A. V. PATIL

    2009-09-01

    Full Text Available Cr2O3 doped ZnO thick films have been prepared by screen printing technique and firing process. These films were characterized by X-ray diffraction (XRD, Scanning electron microscopy (SEM, and EDX. H2S gas sensing properties of these films were investigated at different operating temperatures and different H2S concentrations. The 7 wt. % Cr2O3 doped ZnO thick films exhibits excellent H2S gas sensing properties with maximum sensitivity of 99.12 % at 300 oC in air atmosphere with fast response and recovery time.

  6. Cr{sub 2}O{sub 3} thin films grown at room temperature by low pressure laser chemical vapour deposition

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, P.M. [Universidade de Lisboa, Faculdade de Ciencias, Departamento de Fisica and ICEMS, Campo Grande, Ed. C8, 1749-016 Lisboa (Portugal); Silvestre, A.J., E-mail: asilvestre@deq.isel.ipl.p [Instituto Superior de Engenharia de Lisboa and ICEMS, R. Conselheiro Emidio Navarro 1, 1959-007 Lisboa (Portugal); Conde, O. [Universidade de Lisboa, Faculdade de Ciencias, Departamento de Fisica and ICEMS, Campo Grande, Ed. C8, 1749-016 Lisboa (Portugal)

    2011-03-31

    Chromia (Cr{sub 2}O{sub 3}) has been extensively explored for the purpose of developing widespread industrial applications, owing to the convergence of a variety of mechanical, physical and chemical properties in one single oxide material. Various methods have been used for large area synthesis of Cr{sub 2}O{sub 3} films. However, for selective area growth and growth on thermally sensitive materials, laser-assisted chemical vapour deposition (LCVD) can be applied advantageously. Here we report on the growth of single layers of pure Cr{sub 2}O{sub 3} onto sapphire substrates at room temperature by low pressure photolytic LCVD, using UV laser radiation and Cr(CO){sub 6} as chromium precursor. The feasibility of the LCVD technique to access selective area deposition of chromia thin films is demonstrated. Best results were obtained for a laser fluence of 120 mJ cm{sup -2} and a partial pressure ratio of O{sub 2} to Cr(CO){sub 6} of 1.0. Samples grown with these experimental parameters are polycrystalline and their microstructure is characterised by a high density of particles whose size follows a lognormal distribution. Deposition rates of 0.1 nm s{sup -1} and mean particle sizes of 1.85 {mu}m were measured for these films.

  7. Comparison of low-cycle fatigue data of 2 1/4%CrMo steels

    International Nuclear Information System (INIS)

    Sanderson, S.J.; Petrequin, P.; Nieuwland, H.C.D.

    Data files have been produced on international strain-controlled fatigue information available for 2 1/4%CrMo steels; data assessment from these files is treated in three categories viz: annealed and isothermally annealed 2 1/4%Cr1%Mo steel; normalised and tempered and quenched and tempered 2 1/4%Cr1%Mo steel; and 2 1/4%CrMo variants. The available data have been considered generally in terms of total strain range vs. cycles to failure (Nsub(f)), tensile stress at Nsub(f)/2 vs. cycles to failure and time to failure vs. cycles to failure. Where possible the continuous cycling data have been statistically analysed in terms of the elastic and plastic strain components and cycles to failure to yield best-fit equations over defined temperature (T) regimes viz: T <= 427 deg. C, 427 deg. C < T <= 550 deg. C. and 550 deg. C < T <= 600 deg. C. The behaviour of the steels within the various classifications is discussed. (author)

  8. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Rinderknecht, H. G., E-mail: rinderknecht1@llnl.gov; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C. [State University of New York at Geneseo, Geneseo, New York 14454 (United States); Steidle, Jeffrey A. [Rochester Institute of Technology, Rochester, New York 14623 (United States)

    2015-12-15

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

  9. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    International Nuclear Information System (INIS)

    Rinderknecht, H. G.; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D.; Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C.; Steidle, Jeffrey A.

    2015-01-01

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant

  10. The role of complement receptors type 1 (CR1, CD35) and 2 (CR2, CD21) in promoting C3 fragment deposition and membrane attack complex formation on normal peripheral human B cells

    DEFF Research Database (Denmark)

    Nielsen, Claus Henrik; Pedersen, Morten Løbner; Marquart, Hanne Vibeke Hansen

    2002-01-01

    Normal human B lymphocytes are known to activate the alternative pathway (AP) of complement, leading to C3-fragment deposition and membrane attack complex (MAC) formation. The process is mediated via complement receptor type 2 (CR2, CD21), with complement receptor type 1 (CR1, CD35) playing...... a subsidiary role. In this study, we examine the relative contributions of CR1 and CR2 to the deposition of C3 fragments and MAC on B lymphocytes under circumstances where all complement pathways are operational. C3-fragment deposition and MAC formation were assessed on human peripheral B lymphocytes...... in the presence of 30% autologous serum. Blocking the CR2 ligand-binding site with monoclonal antibody (mAb) FE8 resulted in significant reduction (37.9+/-11.9%) in C3-fragment deposition, whereas MAC formation was only marginally affected (12.1+/-22.2% reduction). Blocking the CR1 binding-site resulted...

  11. Erosion-oxidation behavior of thermal sprayed Ni20Cr alloy and WC and Cr3C2 cermet coatings

    Directory of Open Access Journals (Sweden)

    Clarice Terui Kunioshi

    2005-06-01

    Full Text Available An apparatus to conduct high temperature erosion-oxidation studies up to 850 °C and with particle impact velocities up to 15 m.s-1 was designed and constructed in the Corrosion Laboratories of IPEN. The erosion-oxidation behavior of high velocity oxy fuel (HVOF sprayed alloy and cermet coatings of Ni20Cr, WC 20Cr7Ni and Cr3C2 Ni20Cr on a steel substrate has been studied. Details of this apparatus and the erosion-oxidation behavior of these coatings are presented and discussed. The erosion-oxidation behavior of HVOF coated Cr3C2 25(Ni20Cr was better than that of WC 20Cr7Ni, and the erosion-oxidation regimes have been identified for these coatings at particle impact velocity of 3.5 m.s-1, impact angle of 90° and temperatures in the range 500 to 850 °C.

  12. Evaluation of environmental effect on creep-fatigue of 2 1/4Cr-1Mo steel

    International Nuclear Information System (INIS)

    Yang Beinan; Ishikawa, Akiyoshi; Asada, Yasuhide.

    1991-01-01

    In the present study, a trial evaluation was made to evaluate the environmental effect of air separately from the behavior of material origin. Data with 2 1/4Cr-1Mo steel at 550degC in air were subjected to the evaluation based on data of the steel in high vacuum with a newly developed procedure using the overstress concept. An empirical expression was proposed to describe the environmental effect of air on the creep-fatigue behavior. Following conclusions were obtained in the present study on a separation of the environmental effect of air on a creep-fatigue behavior of 2 1/4Cr-1Mo steel at 550degC. 1) The environmental effect of air reduces a fatigue life, that is, it increases the time-independent damage component of the creep-fatigue. 2) The environmental effect of air brings on the frequency effect which is mainly dependent upon a strain rate or time in a compression going stroke. Other environmental effect on F-S or compression hold-time cycles depends upon the strain rate in compression. 3) The rate-time dependent damage component, that is, the creep damage is reduced by the environmental effect of air. That means a creep-fatigue life recovers in air environment. (author)

  13. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  14. Sintering behaviour and mechanical properties of Cr3C2–NiCr ...

    Indian Academy of Sciences (India)

    fracture toughness. Keywords. Cermet; Cr3C2–NiCr; sintering; mechanical properties. ... et al investigated the mechanical properties of VC, Cr3C2 and NbC doped ..... Huang S G, Li L, Van der Biest O and Vleugels J 2008 J. Alloys. Compds.

  15. Dose optimization in pelvic radiography by air gap method on CR and DR systems – A phantom study

    International Nuclear Information System (INIS)

    Chan, C.T.P.; Fung, K.K.L.

    2015-01-01

    Objectives: This study aimed at investigating the feasibility of replacing the anti-scatter grid with an air gap at a pelvic radiographic examination in order to reduce patient dose while retaining diagnostic image quality. Methods: An anthropomorphic pelvis phantom was placed on a device that allowed the adjustment of different air gap thicknesses introduced between the phantom and the image receptor of Computed Radiography (CR) and Digital Radiography (DR) systems. Grid and non-grid images with different air gap thicknesses of both systems were produced. Ovary and testes doses were measured using thermoluminescent dosimeters. Radiographic quality of all images was rated by 5 experienced radiographers blindly using the Image Quality Score (IQS) and Visual Grading Analysis (VGA) systems. Results: Images of diagnostic quality were produced while the grid was replaced by a range of 0–25 cm air gap thickness in the pelvic radiographic examination. At non-grid examination with 10 cm air gap thickness, a maximum of relative dose reduction by 70.7% and 81.6% at CR; 68.6% and 79.4% at DR were achieved respectively at ovary and testes locations of the phantom as compared with their corresponding grid examinations. Conclusion: 10 cm was found to be the optimal air gap thickness at the tested pelvic examination. Effective dose was found to be reduced by 2 and 2.3 times respectively at the CR and DR examinations while the anti-scatter grid was replaced by 10 cm air gap. However, dose reduction effect by air gap method was found to be more pronounced in CR than in DR. - Highlights: • 10 cm air gap was found to be a substitute to replace grid in pelvic RANDO in CR/DR. • Over 68.6% of dose reduction effect were achieved at the ovary and testes regions. • Over 76.4% of reduction in effective dose were achieved at both the tested regions. • Dose reduction by air gap method was found to be more pronounced in CR than in DR

  16. CX3CL1/CX3CR1 and CCL2/CCR2 Chemokine/Chemokine Receptor Complex in Patients with AMD

    DEFF Research Database (Denmark)

    Falk, Mads Krüger; Singh, Amardeep; Faber, Carsten

    2014-01-01

    PURPOSE: The chemokine receptors CX3CR1 and CCR2 have been implicated in the development of age-related macular degeneration (AMD). The evidence is mainly derived from experimental cell studies and murine models of AMD. The purpose of this study was to investigate the association between expression...... of CX3CR1 and CCR2 on different leukocyte subsets and AMD. Furthermore we measured the plasma levels of ligands CX3CL1 and CCL2. METHODS: Patients attending our department were asked to participate in the study. The diagnosis of AMD was based on clinical examination and multimodal imaging techniques...... positive correlation between CCR2 and CX3CR1 expression on CD8+ cells (r = 0.727, p = 0.0001). We found no difference in plasma levels of CX3CL1 and CCL2 among the groups. CONCLUSIONS: Our results show a down regulation of CX3CR1 on CD8+ cells; this correlated to a low expression of CCR2 on CD8+ cells...

  17. Pr{sup 3+1}S{sub 0}->Cr{sup 3+} energy transfer and ESR investigation in Pr{sup 3+} and Cr{sup 3+} activated SrAl{sub 12}O{sub 19} quantum cutting phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Nie Zhaogang [BK21 Physics Program and Department of Physics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Lim, Ki-Soo, E-mail: kslim@chungbuk.ac.k [BK21 Physics Program and Department of Physics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Zhang Jiahua [Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China); Wang Xiaojun [Department of Physics, Georgia Southern University, Statesboro, GA 30460 (United States)

    2009-08-15

    With the help of the Dexter's theory, the energy transfer mechanism from Pr{sup 3+1}S{sub 0} to Cr{sup 3+} is investigated theoretically in SrAl{sub 12}O{sub 19}:Pr{sup 3+}, Cr{sup 3+} quantum cutting phosphors. The electron spin resonance (ESR) spectra of Pr{sup 3+} and Cr{sup 3+}-doped SrAl{sub 12}O{sub 19} with magnetoplumbite structure have been studied. The Cr{sup 3+} ion is found to enter the Al4(4f) site, which is very close to the Sr(2d) site replaced by the Pr{sup 3+} ions in the host. The theoretical results indicate that the efficient Pr{sup 3+1}S{sub 0}->Cr{sup 3+} energy transfer can only take place in the intermediate mirror planes, in which for the nearest and next-nearest Pr{sup 3+}-Cr{sup 3+} pairs, both dipole-dipole and dipole-quadrupole interactions can play their parts in the transfer. Finally, an overview is given about the research on the energy transfer from Pr{sup 3+1}S{sub 0} to codopants in their co-doped materials.

  18. Radiation dose optimization research: Exposure technique approaches in CR imaging – A literature review

    International Nuclear Information System (INIS)

    Seeram, Euclid; Davidson, Rob; Bushong, Stewart; Swan, Hans

    2013-01-01

    The purpose of this paper is to review the literature on exposure technique approaches in Computed Radiography (CR) imaging as a means of radiation dose optimization in CR imaging. Specifically the review assessed three approaches: optimization of kVp; optimization of mAs; and optimization of the Exposure Indicator (EI) in practice. Only papers dating back to 2005 were described in this review. The major themes, patterns, and common findings from the literature reviewed showed that important features are related to radiation dose management strategies for digital radiography include identification of the EI as a dose control mechanism and as a “surrogate for dose management”. In addition the use of the EI has been viewed as an opportunity for dose optimization. Furthermore optimization research has focussed mainly on optimizing the kVp in CR imaging as a means of implementing the ALARA philosophy, and studies have concentrated on mainly chest imaging using different CR systems such as those commercially available from Fuji, Agfa, Kodak, and Konica-Minolta. These studies have produced “conflicting results”. In addition, a common pattern was the use of automatic exposure control (AEC) and the measurement of constant effective dose, and the use of a dose-area product (DAP) meter

  19. Strategies for dose reduction in ordinary radiographic examinations using CR and DR

    International Nuclear Information System (INIS)

    Willis, C.E.

    2004-01-01

    Uncoupling of display from acquisition in computed radiography (CR) and digital radiography (DR) introduces the potential for systematic overexposure without necessarily compromising image quality. Although the magnitude of radiation doses in general radiography is low compared to computed tomography and fluoroscopy, the dose to the patient is more critical in pediatric examinations than in adults, because of the greater radiosensitivity of children. This manuscript examines a variety of countermeasures for managing radiation doses in pediatric CR and DR examinations, including use of derived exposure indicators, modifications of imaging practice, and development of more efficient radiographic detectors. (orig.)

  20. Toughness of 2,25Cr-1Mo steel and weld metal

    Science.gov (United States)

    Acarer, Mustafa; Arici, Gökhan; Acar, Filiz Kumdali; Keskinkilic, Selcuk; Kabakci, Fikret

    2017-09-01

    2,25Cr-1Mo steel is extensively used at elevated temperature structural applications in fossil fire power plants for steam pipes, nozzle chambers and petrochemical industry for hydrocracking unit due to its excellent creep resistance and good redundant to oxidation. Also they should have acceptable weldability and toughness. The steels are supplied in quenched and tempered condition and their welded components are subjected to post-weld heat treatment (PWHT). Tempering process is carried out at 690-710°C to improve toughness properties. However they are sensitive to reheat cracking and temper embrittlement. To measure temper embrittlement of the steels and their weld metal, temper embrittlement factor and formula (J factor - Watanabe and X formula- Bruscato) are used. Step cooling heat treatment is also applied to determine temper embrittlement. In this study, toughness properties of Cr Mo (W) steels were reviewed. Also transition temperature curves of 2,25Cr-1Mo steel and its weld metal were constructed before and after step cool heat treatment as experimental study. While 2,25Cr-1Mo steel as base metal was supplied, all weld metal samples were produced in Gedik Welding Company. Hardness measurements and microstructure evaluation were also carried out.

  1. Kinetic stable Cr isotopic fractionation between aqueous Cr(III)-Cl-H2O complexes at 25 °C: Implications for Cr(III) mobility and isotopic variations in modern and ancient natural systems

    Science.gov (United States)

    Babechuk, Michael G.; Kleinhanns, Ilka C.; Reitter, Elmar; Schoenberg, Ronny

    2018-02-01

    The stable Cr isotope fractionation preserved in natural substances has been attributed predominantly to Cr(III)-Cr(VI) redox transformations. However, non-redox reaction pathways (e.g., ligand-promoted dissolution, ligand exchange, adsorption of Cr(III)) are liable to contribute to isotopic fractionation in natural systems given that soluble Cr(III)-ligands have been directly documented or modeled in several marine, continental, and hydrothermal environments. This study isolates the stable Cr isotope fractionation accompanying Cl-H2O ligand exchange during the transformation of three aqueous species in the Cr(III)-Cl-H2O system, [CrCl2(H2O)4]+aq (abr. CrCl2+ or S1), [CrCl(H2O)5]2+aq (abr. CrCl2+ or S2), and [Cr(H2O)6]3+aq (abr. Cr3+ or S3), at low pH (≤2). In dilute HCl (0.01 to 1 M), Cr3+ is the kinetically favoured species and transformation of CrCl2+ to CrCl2+ to Cr3+ via 2 steps of dechlorination/hydrolyzation begins immediately upon dissolution of a Cr(III)-Cl solid. Individual species are separated with cation exchange chromatography at different stages of transformation and inter- and intra-species (across an elution peak of one species) isotopic fractionation of up to 1 and 2‰ (δ53/52Cr), respectively, is documented. Comparison of peak elution characteristics with Cr-Cl-H-O isotopologue mass abundances suggests mass-dependent sorting of isotopologues alone cannot explain intra-species fractionation, supporting a previously published proposal that preferential adsorption of light Cr isotopes on the resin is driven by vibrational energy effects. The transformation of CrCl2+ to CrCl2+ is faster than CrCl2+ to Cr3+ and the rates of both transformations increase with solution pH. Preferential reaction of light Cr(III) isotopes into product species occurs during each transformation, consistent with closed-system, kinetic fractionation during Cl-H2O ligand exchange. Inter-species fractionation is assessed using time-series experiments beginning from the

  2. The study of Cr3+/Cr2+ redox system by polarographic method

    Directory of Open Access Journals (Sweden)

    S. A. Pokhmyolkina

    2014-08-01

    of redox Cr+3/ Cr+2. The specific reaction rate found by extrapolating the straight line constructed in the lgK = f (E coordinates to the equilibrium potential Ep. Equilibrium potential found by the Eyring method as half-wave potential for the reversible waves.We have constructed the initial currents of irreversible waves, considering that the beginning of irreversible and reversible waves practically coincide. Specific reaction rate (K is associated with activation energy given by: lgK= lg(ВТ/h∙ δ – ΔF/2,3RT, where: B is the Boltzmann constant, T is temperature Kelvin , h - Planck constant , δ - the distance between ions 2 ∙ 10-8 cm , R - universal gas constant , ΔF- changing activation energy. Substituting the values of the constants in the equation, we obtain an expression for calculating the activation energy: ΔF = 6,86∙103 – 1,35∙103lgК. An important characteristic of irreversible processes is the change in entropy, as the derivative of the entropy increment in time (diS / dt = ΔS. This quantity can be expressed in terms of current strength (J and overvoltage (η: ΔS = (diS / dt = 1 / T ∙ J η. In polarographic it indicates that the electrochemical process is complicated as compared with delivery of reactant to the electrode. With increasing temperature, we saw insignificant changes in the kinetic characteristics of both anodic and cathodic reduction of chromium salts. Obviously, accelerate the process of discharging ions prevents complication. Conclusion. This indicates a different state of ions of bivalent and trivalent chromium in solution and various ways of the electrode processes.

  3. Mechanisms and rates of proton transfer to coordinated carboxydithioates: studies on [Ni(S2CR){PhP(CH2CH2PPh2)2}](+) (R = Me, Et, Bu(n) or Ph).

    Science.gov (United States)

    Alwaaly, Ahmed; Clegg, William; Henderson, Richard A; Probert, Michael R; Waddell, Paul G

    2015-02-21

    The complexes [Ni(S2CR)(triphos)]BPh4 (R = Me, Et, Bu(n) or Ph; triphos = PhP{CH2CH2PPh2}2) have been prepared and characterised. X-ray crystallography (for R = Et, Ph, C6H4Me-4, C6H4OMe-4 and C6H4Cl-4) shows that the geometry of the five-coordinate nickel in the cation is best described as distorted trigonal bipyramidal, containing a bidentate carboxydithioate ligand with the two sulfur atoms spanning axial and equatorial sites, the other axial site being occupied by the central phosphorus of triphos. The reactions of [Ni(S2CR)(triphos)](+) with mixtures of HCl and Cl(-) in MeCN to form equilibrium solutions containing [Ni(SH(S)CR)(triphos)](2+) have been studied using stopped-flow spectrophotometry. The kinetics show that proton transfer is slower than the diffusion-controlled limit and involves at least two coupled equilibria. The first step involves the rapid association between [Ni(S2CR)(triphos)](+) and HCl to form the hydrogen-bonded precursor, {[Ni(S2CR)(triphos)](+)HCl} (K) and this is followed by the intramolecular proton transfer (k) to produce [Ni(SH(S)CR)(triphos)](2+). In the reaction of [Ni(S2CMe)(triphos)](+) the rate law is consistent with the carboxydithioate ligand undergoing chelate ring-opening after protonation. It seems likely that chelate ring-opening occurs for all [Ni(S2CR)(triphos)](+), but only with [Ni(S2CMe)(triphos)](+) is the protonation step sufficiently fast that chelate ring-opening is rate-limiting. With all other systems, proton transfer is rate-limiting. DFT calculations indicate that protonation can occur at either sulfur atom, but only protonation at the equatorial sulfur results in chelate ring-opening. The ways in which protonation of either sulfur atom complicates the analyses and interpretation of the kinetics are discussed.

  4. Trans-1,4 selective polymerization of 1,3-butadiene with symmetry pincer chromium complexes activated by MMAO

    KAUST Repository

    Gong, Dirong; Jia, Xiaoyu; Wang, Baolin; Zhang, Xuequan; Huang, Kuo-Wei

    2014-01-01

    Tridentate chromium complexes (Cr1-Cr7) incorporated with symmetrical pincer ligand bis(arylimino)pyridine and bis(pyrzaolyl)pyridine have been synthesized and characterized by elemental analyis, FT-IR as well as ESI-MS. X-ray diffraction reveals solids-state structures of Cr2, Cr4 and Cr6 all adopt pseudo-octahedral coordination environment with respect to metal center. All complexes have been tested in stereoregulated polymerization of butadiene under various polymerization conditions. The trans-1,4 and cis-1,4 enchainment of resultant polymer are found to be dependent on the structure of ligand and amount of activator used. Under the optimized condition, free ortho-substitutes Cr catalysts Cr1, Cr3, Cr4 and Cr6 are capable of initiating high trans-1,4 selectivity (trans-1,4: 89.2%-92.0%) with good polymer yields (71.5%-78.0%), while counterparts with ortho-positioned alkyl groups Cr2, Cr5 and Cr7 display mixed selectivities with moderate polymer yields. The sterical effect of ligand and amount of MMAO on the catalytic performance, in particular, the stereoselectivity and polymer yield, has been also elucidated by conjugated diene polymerization mechanism. © 2014 Elsevier B.V. All rights reserved.

  5. Trans-1,4 selective polymerization of 1,3-butadiene with symmetry pincer chromium complexes activated by MMAO

    KAUST Repository

    Gong, Dirong

    2014-09-01

    Tridentate chromium complexes (Cr1-Cr7) incorporated with symmetrical pincer ligand bis(arylimino)pyridine and bis(pyrzaolyl)pyridine have been synthesized and characterized by elemental analyis, FT-IR as well as ESI-MS. X-ray diffraction reveals solids-state structures of Cr2, Cr4 and Cr6 all adopt pseudo-octahedral coordination environment with respect to metal center. All complexes have been tested in stereoregulated polymerization of butadiene under various polymerization conditions. The trans-1,4 and cis-1,4 enchainment of resultant polymer are found to be dependent on the structure of ligand and amount of activator used. Under the optimized condition, free ortho-substitutes Cr catalysts Cr1, Cr3, Cr4 and Cr6 are capable of initiating high trans-1,4 selectivity (trans-1,4: 89.2%-92.0%) with good polymer yields (71.5%-78.0%), while counterparts with ortho-positioned alkyl groups Cr2, Cr5 and Cr7 display mixed selectivities with moderate polymer yields. The sterical effect of ligand and amount of MMAO on the catalytic performance, in particular, the stereoselectivity and polymer yield, has been also elucidated by conjugated diene polymerization mechanism. © 2014 Elsevier B.V. All rights reserved.

  6. Chemical reduction of rust on 2 1/4 Cr-1 Mo steel surface in sodium

    International Nuclear Information System (INIS)

    Yokota, N.; Shimoyashiki, S.

    1986-01-01

    Low-alloy Fe-2 1/4 Cr-1 Mo ferritic steel has been favored for the tube material of steam generators in fast breeder reactors (FBRs). However, this material rusts easily due to moisture condensation on its surface when left in air. Therefore, measures to prevent tube materials from rusting have been taken during manufacturing of the steam generators. When rust is present on tube surfaces, its oxygen and iron dissolve into liquid sodium. When the concentration of these impurities in the sodium increases rapidly, the cold traps can become choked locally and lose their removal ability. This work has been done, therefore, to clarify reduction processes of rust in sodium and to select optimum operating temperatures of steam generators in the initial operation

  7. Applications of Cr:ZnSe and Cr:ZnS lasers to ultrabroadband high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Sorokin, E.; Sorokina, I.; Picque, N.; Guelachvili, G.

    2006-01-01

    Full text: Cr 2+ :ZnSe laser, and since recently also the Cr 2+ :ZnS laser proved to be versatile laser sources for trace gas measurements in the whole range between 2 and 3.1 μm. Among the existing methods of sensitive gas detection, intracavity laser absorption spectroscopy (ICLAS) offers some distinct advantages such as the simultaneous coverage of a broad spectral domain and large dynamic range. Under ICLAS the absorbing medium is put inside a laser cavity with broadband gain. As a result, the laser cavity acts as a multipass cell. Equivalent absorption path length of tens of kilometers can be achieved, corresponding to high detection sensitivities of the order of 10 -8 cm -1 and better. Only few examples of ICLAS spectrometers were demonstrated beyond 2 μm. Among them are: KCl:Li Fa(II) color center laser with coverage up to 4 nm at 2638 nm, Co:MgF 2 , covering up to 30 nm around 2040 and 2245 nm, Tm:YAG with coverage up to 35 nm at 2030 nm, and pulsed Cr:ZnSe, with coverage up to 50 nmat 2500 nm. In this talk we discuss application of a Cr 2+ :ZnSe laser to high-resolution and high-sensitivity intracavity absorption spectroscopy (ICLAS) analyzed by time-resolved Fourier transform spectroscopy. This represents the extreme limit presently reached in the infrared by ICLAS with Doppler limited resolution. Our most recent works concern application of a Cr 2+ :ZnS laser for broadband ultrasensitive intracavity laser spectroscopy (ICLAS), with effective absorption path up to about 50 km in the 2.4 μm range. The spectrometer operates with both Er-fiber and direct diode pumping in the very interesting water-free window between ∼ 2.1 and 2.5 μm. The sensitivity of 2 x 10 -9 cm -1 at Doppler-limited resolution allows obtaining spectral information that was previously unreachable in laboratory conditions. Summarizing, intracavity laser spectroscopy technique has been successfully used for measuring and detecting gas constituents with extreme sensitivity and

  8. Optical, structural, and chemical properties of CR-39 implanted with 5.2 MeV doubly charged carbon ions

    Science.gov (United States)

    Ali, Dilawar; Butt, M. Z.; Ishtiaq, Mohsin; Waqas Khaliq, M.; Bashir, Farooq

    2016-11-01

    Poly-allyl-diglycol-carbonate (CR-39) specimens were irradiated with 5.2 MeV doubly charged carbon ions using Pelletron accelerator. Ion dose was varied from 5 × 1013 to 5 × 1015 ions cm-2. Optical, structural, and chemical properties were investigated by UV-vis spectroscopy, x-ray diffractometer, and FTIR/Raman spectroscopy, respectively. It was found that optical absorption increases with increasing ion dose. Absorption edge shifts from UV region to visible region. The measured opacity values of pristine and ion implanted CR-39 range from 0.0519 to 4.7959 mm-1 following an exponential growth (9141%) with the increase in ion dose. The values of direct and indirect band gap energy decrease exponentially with an increase in ion dose by 59% and 71%, respectively. However, average refractive index in the visible region increases from 1.443 to 2.864 with an increase in ion dose, by 98%. A linear relation between band gap energy and crystallite size was observed. Both the number of carbon atoms in conjugation length and the number of carbon atoms per cluster increase linearly with the increase in ion dose. FTIR spectra showed that on C+2 ions irradiation, the intensity of all bands decreases gradually without appearance of any new band, indicating degradation of polymer after irradiation. Raman spectra revealed that the density of -CH2- group decreases on C+2 ions irradiation. However, the structure of CR-39 is completely destroyed on irradiation with ion dose 1 × 1015 and 5 × 1015 ions cm-2.

  9. Effects of sodium environment on the mechanical properties of Fe-2 1/4Cr-1Mo steel

    International Nuclear Information System (INIS)

    Chopra, O.K.

    1983-09-01

    Mechanical property data on isothermally annealed, thermally aged, and sodium-exposed Fe-2 1/4Cr-1Mo steel are analyzed to evaluate the influence of the sodium environment as well as the effects of the microstructural and compositional changes that occur in the steel during long-term exposure to sodium. Correlations are developed to predict the environmental effects on tensile, creep, fatigue, and creep-fatigue properties of Fe-2 1/4Cr-1Mo steel in sodium. The results indicate that at temperatures 0 C), degradation of mechanical properties is essentially due to thermal aging. Loss of carbon from the steel reduces both the tensile and creep-rupture strength, but has little or no effect on the fatigue properties. The cyclic properties of Fe-2 1/4Cr-1Mo steel in sodium are superior to those in air. The creep-fatigue behavior in sodium is significantly different from that in an air environment. The creep-fatigue data are analyzed using the interactive damage rate equations to predict the time-dependent fatigue behavior of isothermally annealed Fe-2 1/4Cr-1Mo steel in sodium. 15 references, 7 figures, 1 table

  10. Homogeneous and Heterogeneous (Fex, Cr1-x)(OH)3 Precipitation: Implications for Cr Sequestration.

    Science.gov (United States)

    Dai, Chong; Zuo, Xiaobing; Cao, Bo; Hu, Yandi

    2016-02-16

    The formation of (Fe, Cr)(OH)3 nanoparticles determines the fate of aqueous Cr in many aquatic environments. Using small-angle X-ray scattering, precipitation rates of (Fe, Cr)(OH)3 nanoparticles in solution and on quartz were quantified from 0.1 mM Fe(III) solutions containing 0-0.25 mM Cr(III) at pH = 3.7 ± 0.2. Concentration ratio of aqueous Cr(III)/Fe(III) controlled the chemical composition (x) of (Fex, Cr1-x)(OH)3 precipitates, solutions' supersaturation with respect to precipitates, and the surface charge of quartz. Therefore, the aqueous Cr(III)/Fe(III) ratio affected homogeneous (in solution) and heterogeneous (on quartz) precipitation rates of (Fex, Cr1-x)(OH)3 through different mechanisms. The sequestration mechanisms of Cr(III) in precipitates were also investigated. In solutions with high aqueous Cr(III)/Fe(III) ratios, surface enrichment of Cr(III) on the precipitates occurred, resulting in slower particle growth in solutions. From solutions with 0-0.1 mM Cr(III), the particles on quartz grew from 2 to 4 nm within 1 h. Interestingly, from solution with 0.25 mM Cr(III), particles of two distinct sizes (2 and 6 nm) formed on quartz, and their sizes remained unchanged throughout the reaction. Our study provided new insights on homogeneous and heterogeneous precipitation of (Fex, Cr1-x)(OH)3 nanoparticles, which can help determine the fate of Cr in aquatic environments.

  11. The effects of lower than conventional doses of oral nadolol on relative beta 1/beta 2-adrenoceptor blockade.

    Science.gov (United States)

    Wheeldon, N M; McDevitt, D G; Lipworth, B J

    1994-08-01

    1. The aim of the present study was to evaluate the relative beta 1/beta 2 antagonist selectivity of the beta-adrenoceptor blocker nadolol, in lower than conventional clinical doses. 2. Eight normal volunteers received single oral doses of either placebo (PL), nadolol 5 mg (N5), 20 mg (N20) or 80 mg (N80) in a single-blind, randomised crossover design. beta 1-adrenoceptor antagonism was assessed by attenuation of exercise tachycardia, and beta 2-adrenoceptor blockade by effects on salbutamol-induced chronotropic, hypokalaemic and finger tremor responses. The relative percentage attenuation of beta 2 and beta 1-mediated responses was calculated and expressed as beta 2:beta 1 selectivity ratios. 3. Nadolol produced dose-related reductions in exercise tachycardia in keeping with increasing beta 1-adrenoceptor blockade; mean % reduction (95% CI) compared with placebo: N5 10.7 (6.6 to 14.8), N20 21.4 (17.3 to 25.4), N80 38.9 (34.8 to 42.9). However, even the lowest dose of nadolol (5 mg) produced almost complete blunting of beta 2-mediated effects and significantly increase exercise hyperkalaemia; peak exercise hyperkalaemia (mmol l-1) (means and 95% CI): PL 4.88 (4.68 to 5.07), N5 5.36 (5.17 to 5.55), N20 5.48 (5.28 to 5.67), N80 5.42 (5.22 to 5.61). beta 2:beta 1 selectivity ratios significantly increased as the dose of nadolol was reduced. 4. These data suggest that whereas in the clinical dose range nadolol behaves as a non-selective beta-adrenoceptor antagonist, as the dose is reduced this drug demonstrates an increasing degree of selectivity for the beta 2-adrenoceptor.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Effects of sodium environment on the mechanical properties of Fe-2 1/4Cr-1Mo steel

    International Nuclear Information System (INIS)

    Chopra, O.K.

    Mechanical property data on isothermally annealed, thermally aged, and sodium-exposed Fe-2 1/4Cr-1Mo steel are analyzed to evaluate the influence of the sodium environment as well as the effects of the microstructural and compositional changes that occur in the steel during long-term exposure to sodium. Correlations are developed to predict the environmental effects on tensile, creep, fatigue, and creep-fatigue properties of Fe-2 1/4Cr-1Mo steel in sodium. The results indicate that at temperatures <823 K (550 deg. C), degradation of mechanical properties is essentially due to thermal aging. Loss of carbon from the steel reduces both the tensile and creep-rupture strength, but has little or no effect on the fatigue properties. The cyclic properties of Fe-2 1/4Cr-1Mo steel in sodium are superior to those in air. The creep-fatigue behaviour in sodium is significantly different from that in an air environment. The creep-fatigue data are analyzed using the interactive damage rate equations to predict the time-dependent fatigue bahaviour of isothermally annealed Fe-2 1/4Cr-1Mo steel in sodium. (author)

  13. Image quality, threshold contrast and mean glandular dose in CR mammography

    International Nuclear Information System (INIS)

    Jakubiak, R R; Gamba, H R; Neves, E B; Peixoto, J E

    2013-01-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both

  14. Effects of high neutron doses and duration of the chemical etching on the optical properties of CR-39

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Paul, S.; Sharma, S.C.; Joshi, D.S.; Gupta, A.K.; Bandyopadhyay, T.

    2015-01-01

    Effects of the duration of chemical etching on the transmittance, absorbance and optical band gap width of the CR-39 (Polyallyl diglycol carbonate) detectors irradiated to high neutron doses (12.7, 22.1, 36.0 and 43.5 Sv) were studied. The neutrons were produced by bombardment of a thick Be target with 12 MeV protons of different fluences. The unirradiated and neutron-irradiated CR-39 detectors were subjected to a stepwise chemical etching at 1 h intervals. After each step, the transmission spectra of the detectors were recorded in the range from 200 to 900 nm, and the absorbances and optical band gap widths were determined. The effect of the etching on the light transmittance of unirradiated detectors was insignificant, whereas it was very significant in the case of the irradiated detectors. The dependence of the optical absorbance on the neutron dose is linear at short etching periods, but exponential at longer ones. The optical band gap narrows with increasing etching time. It is more significant for the irradiated dosimeters than for the unirradiated ones. The rate of the narrowing of the optical band gap with increasing neutron dose increases with increasing duration of the etching. - Highlights: • The variation of optical properties of CR-39 at very high neutron dose is analyzed. Etching process is found to play a crucial role for change in optical properties of neutron-irradiated CR-39. • The optical absorbance varies linearly at lower dose, at very high dose absorbance saturation occurs. The dose at which saturation absorbance is observed shifts towards lower neutron dose with increase in etching time. • The rate of decrease in optical band gap with respect to neutron dose is found to be more at higher etching durations

  15. Removal of Cr6 + and Ni2+ from aqueous solution using bagasse and fly ash.

    Science.gov (United States)

    Rao, M; Parwate, A V; Bhole, A G

    2002-01-01

    Raw bagasse and fly ash, the waste generated in sugar mills and boilers respectively have been used as low-cost potential adsorbents. Raw bagasse was pretreated with 0.1N NaOH followed by 0.1N CH3COOH before its application. These low-cost adsorbents were used for the removal of chromium and nickel from an aqueous solution. The kinetics of adsorption and extent of adsorption at equilibrium are dependent on the physical and chemical characteristics of the adsorbent, adsorbate and experimental system. The effect of hydrogen ion concentration, contact time, sorbent dose, initial concentrations of adsorbate and adsorbent and particle size on the uptake of chromium and nickel were studied in batch experiments. The Sorption data has been correlated with Langmuir, Freundlich and Bhattacharya and Venkobachar adsorption models. The efficiencies of adsorbent materials for the removal of Cr(VI) and Ni(II) were found to be between 56.2 and 96.2% and 83.6 and 100%, respectively. These results were obtained at the optimized conditions of pH, contact time, sorbent dose, sorbate concentration of 100 mg/l and with the variation of adsorbent particles size between 0.075 and 4.75 mm. The order of selectivity is powdered activated carbon > bagasse > fly ash for Cr(VI) removal and powdered activated carbon > fly ash > bagasse for Ni(II) removal.

  16. Structural, morphological, and optical characterizations of Mo, CrN and Mo:CrN sputtered coatings for potential solar selective applications

    Science.gov (United States)

    Ibrahim, Khalil; Mahbubur Rahman, M.; Taha, Hatem; Mohammadpour, Ehsan; Zhou, Zhifeng; Yin, Chun-Yang; Nikoloski, Aleksandar; Jiang, Zhong-Tao

    2018-05-01

    Mo, CrN, and Mo:CrN sputtered coatings synthesized onto silicon Si(100) substrates were investigated as solar selective surfaces and their potential applications in optical devices. These coatings were characterized using XRD, SEM, UV-vis, and FTIR techniques. XRD investigation, showed a change in CrN thin film crystallite characteristic due to Mo doping. Compared to the CrN coating, the Mo:CrN film has a higher lattice parameter and lower grain size of 4.19 nm and 106.18 nm, respectively. FESEM morphology confirmed the decrement in Mo:CrN crystal size due to Mo doping. Optical analysis showed that in the visible range of the solar spectrum, the CrN coatings exhibit the highest solar absorptance of 66% while the lowest thermal emittance value of 5.67 was recorded for the CrN coating doped with Mo. Consequently, the highest solar selectivity of 9.6, and the energy band-gap of 2.88 eV were achieved with the Mo-doped CrN coatings. Various optical coefficients such as optical absorption coefficient, refractive index, extinction coefficient, real and imaginary parts of dielectric constants, and energy loss functions of these coatings were also estimated from the optical reflectance data recorded in the wavelength range of 190-2300 nm.

  17. Discovery of Clinical Candidate 2-((2S,6 S)-2-Phenyl-6-hydroxyadamantan-2-yl)-1-(3'-hydroxyazetidin-1-yl)ethanone [BMS-816336], an Orally Active Novel Selective 11β-Hydroxysteroid Dehydrogenase Type 1 Inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Xiang-Yang; Chen, Stephanie Y.; Wu, Shung; Yoon, David S.; Wang, Haixia; Hong, Zhenqiu; O’Connor, Stephen P.; Li, Jun; Li, James J.; Kennedy, Lawrence J.; Walker, Steven J.; Nayeem, Akbar; Sheriff, Steven; Camac, Daniel M.; Ramamurthy, Vidyhashankar; Morin, Paul E.; Zebo, Rachel; Taylor, Joseph R.; Morgan, Nathan N.; Ponticiello, Randolph P.; Harrity, Thomas; Apedo, Atsu; Golla, Rajasree; Seethala, Ramakrishna; Wang, Mengmeng; Harper, Timothy W.; Sleczka, Bogdan G.; He, Bin; Kirby, Mark; Leahy, David K.; Li, Jianqing; Hanson, Ronald L.; Guo, Zhiwei; Li, Yi-Xin; DiMarco, John D.; Scaringe, Raymond; Maxwell, Brad; Moulin, Frederick; Barrish, Joel C.; Gordon, David A.; Robl, Jeffrey A.

    2017-06-05

    BMS-816336 (6n-2), a hydroxy-substituted adamantyl acetamide, has been identified as a novel, potent inhibitor against human 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) enzyme (IC50 3.0 nM) with >10000-fold selectivity over human 11β-hydroxysteroid dehydrogenase type 2 (11β-HSD2). 6n-2 exhibits a robust acute pharmacodynamic effect in cynomolgus monkeys (ED50 0.12 mg/kg) and in DIO mice. It is orally bioavailable (%F ranges from 20 to 72% in preclinical species) and has a predicted pharmacokinetic profile of a high peak to trough ratio and short half-life in humans. This ADME profile met our selection criteria for once daily administration, targeting robust inhibition of 11β-HSD1 enzyme for the first 12 h period after dosing followed by an “inhibition holiday” so that the potential for hypothalamic–pituitary–adrenal (HPA) axis activation might be mitigated. 6n-2 was found to be well-tolerated in phase 1 clinical studies and represents a potential new treatment for type 2 diabetes, metabolic syndrome, and other human diseases modulated by glucocorticoid control.

  18. Structural, magnetic, and dielectric properties of multiferroic Co{sub 1−x}Mg{sub x}Cr{sub 2}O{sub 4} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, M.; Ullah, A. [Nanomagnetism and Nanotechnology Laboratory, International Islamic University, Islamabad 44000 (Pakistan); Rahman, S. [Department of Material Science and Engineering, University of Science and Technology of China Hefei, Anhui 230026 (China); Tahir, A. [Department of Physics, Quaid-e-Azam University, Islamabad 44000 (Pakistan); Nadeem, K., E-mail: kashif.nadeem@iiu.edu.pk [Nanomagnetism and Nanotechnology Laboratory, International Islamic University, Islamabad 44000 (Pakistan); Beijing National Laboratory for Condensed Matter Physics, National Laboratory for Superconductivity, Institute of Physics, Chinese Academy of Sciences, P.O. Box 603, Beijing 100190 (China); Anis ur Rehman, M. [Applied Thermal Physics Laboratory, Department of Physics, COMSATS Institute of Information Technology, Islamabad 44000 (Pakistan); Hussain, S. [Magnetism Laboratory, Department of Physics, COMSATS Institute of Information Technology, Islamabad 44000 (Pakistan)

    2017-07-01

    Highlights: • Properties of multiferroic Co{sub 1−x}Mg{sub x}Cr{sub 2}O{sub 4} nanoparticles have been studied. • XRD showed that CoCr{sub 2}O{sub 4} and MgCr{sub 2}O{sub 4} are cubic normal spinel structure. • Rietveld refinement of XRD showed no impurity phases. • T{sub c} and T{sub s} showed decreasing trend with increasing Mg concentration. • Dielectric properties were improved for x = 0.6 Mg concentration. - Abstract: We examined the structural, magnetic, and dielectric properties of Co{sub 1−x}Mg{sub x}Cr{sub 2}O{sub 4} nanoparticles with composition x = 0, 0.2, 0.4, 0.5, 0.6, 0.8 and 1 in detail. X-ray diffraction (XRD) revealed normal spinel structure for all the samples. Rietveld refinement fitting results of the XRD showed no impurity phases which signifies the formation of single phase Co{sub 1−x}Mg{sub x}Cr{sub 2}O{sub 4} nanoparticles. The average crystallite size showed a peak behaviour with maxima at x = 0.6. Raman and Fourier transform infrared (FTIR) spectroscopy also confirmed the formation of single phase normal spinel for all the samples and exhibited dominant vibrational changes for x ≥ 0.6. For x = 0 (CoCr{sub 2}O{sub 4}), zero field cooled/field cooled (ZFC/FC) magnetization curves showed paramagnetic (PM) to ferrimagnetic (FiM) transition at T{sub c} = 97 K and a conical spiral magnetic order at T{sub s} = 30 K. The end members CoCr{sub 2}O{sub 4} (x = 0) and MgCr{sub 2}O{sub 4} (x = 1) are FiM and antiferromagnetic (AFM), respectively. T{sub c} and T{sub s} showed decreasing trend with increasing x, followed by an additional AFM transition at T{sub N} = 15 K for x = 0.6. The system finally stabilized and changed to highly frustrated AFM structure at x = 1 due to formation of pure MgCr{sub 2}O{sub 4}. High field FC curves (5T) depicted nearly no effect on spiral magnetic state, which is attributed to strong exchange B-B magnetic interactions at low temperatures. Dielectric parameters showed a non-monotonous behaviour with

  19. CR4056, a new analgesic I2 ligand, is highly effective against bortezomib-induced painful neuropathy in rats

    Directory of Open Access Journals (Sweden)

    Meregalli C

    2012-06-01

    Full Text Available Cristina Meregalli,1 Cecilia Ceresa,1 Annalisa Canta,1 Valentina Alda Carozzi,1 Alessia Chiorazzi,1 Barbara Sala,1 Norberto Oggioni,1 Marco Lanza,2 Ornella Letar,i2 Flora Ferrari,2 Federica Avezza,1 Paola Marmiroli,1 GianFranco Caselli,2 Guido Cavaletti11Department of Neuroscience and Biomedical Technologies, University of Milan-Bicocca, 2Pharmacology and Toxicology Department, Rottapharm | Madaus Research Center, Monza, ItalyAbstract: Although bortezomib (BTZ is the frontline treatment for multiple myeloma, its clinical use is limited by the occurrence of painful peripheral neuropathy, whose treatment is still an unmet clinical need. Previous studies have shown chronic BTZ administration (0.20 mg/kg intravenously three times a week for 8 weeks to female Wistar rats induced a peripheral neuropathy similar to that observed in humans. In this animal model of BTZ-induced neurotoxicity, the present authors evaluated the efficacy of CR4056, a novel I2 ligand endowed with a remarkable efficacy in several animal pain models. CR4056 was administered in a wide range of doses (0.6–60 mg/kg by gavage every day for 2–3 weeks in comparison with buprenorphine (Bupre (28.8 µg/kg subcutaneously every day for 2 weeks and gabapentin (Gaba (100 mg/kg by gavage every day for 3 weeks. Chronic administration of BTZ reduced nerve conduction velocity and induced allodynia. CR4056, Bupre, or Gaba did not affect the impaired nerve conduction velocity. Conversely, CR4056 dose-dependently reversed BTZ-induced allodynia (minimum effective dose 0.6 mg/kg. The optimal dose found, 6 mg/kg, provided a constant pain relief throughout the treatment period and without rebound after suspension, being effective when coadministered with BTZ, starting before or after allodynia was established, or when administered alone after BTZ cessation. A certain degree of tolerance was seen after 7 days of administration, but only at the highest doses (20 and 60 mg/kg. Bupre was effective

  20. Notochord in Tilapia nilotica Exposed to Sublethal Dose of Malathion, S[1, 2-Di(EthoxycarbonylEthyl] Dimethyl Phosphorothiolothionate

    Directory of Open Access Journals (Sweden)

    Edna Amparado

    1992-06-01

    Full Text Available Exposure of Tilapia nilotica embryos to sublethal dose of 1.0 ppm commercial grade malathion, S[1,2-di(ethoxycarbonylethyl] dimethyl phosphorothiolothionate from day-10 post fertilization resulted in notochordal aberrations. Pesticide-treated fishes exhibited constriction of the notochordal sheath, folding at the posterior sections and larger notochord than those of the control group.

  1. Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

    CERN Document Server

    Yamauchi, T; Oda, K; Ikeda, T; Honda, Y; Tagawa, S

    1999-01-01

    The effect of gamma-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved was assumed to dominate the damage formation process.

  2. Characterization of mechanical properties and electrochemical behaviour in a Hank´s solution of 316L/Cr1-xAlxN system

    International Nuclear Information System (INIS)

    Osorio, D M; Caicedo, J C; Zambrano, G; Aperador, W; Benitez-Castro, A M; Giraldo-Betancur, A L; Muñoz-Saldaña, J; Yañez-Limón, J M; Sanchez, O

    2017-01-01

    Cr 1-x Al x N hard coatings were successfully deposited by R.F. reactive magnetron co-sputtering in an Ar/N2 gas mixture using chromium and aluminium targets on 316L stainless steel substrates. Crystallographic orientations associated to the Cr 1-x Al x N FCC based in the conjugate complex of CrN and w-AlN phases, with ao=4.18Å lattice parameter for the ternary Cr 1-x Al x N compound were identified by X-Ray diffraction. The thickness and roughness of the deposited coatings are 1.00±0.05nm and 2.65±0.6nm, respectively. The mechanical properties were determined by nanoindentation leading to a hardness of 27.8±2.6GPa and elastic modulus of 346GPa. The corrosion resistance of the coated 316L/Cr 1-x Al x N system under simulated body fluid (SBF, Hank’s solution) was determined via electrochemical impedance spectroscopy. A reduction in the corrosion rate of 99% in relation to uncoated 316L stainless steel substrate was found by Tafel. Thus, these coatings seem to be excellent candidates to be used in biomedical applications. (paper)

  3. Structural, thermal and photomagnetic properties of spin crossover [Fe(bpp)2]2+ salts bearing [Cr(L)(ox)2]- anions.

    Science.gov (United States)

    Clemente-León, Miguel; Coronado, Eugenio; Giménez-López, M Carmen; Romero, Francisco M; Asthana, Saket; Desplanches, Cédric; Létard, Jean-François

    2009-10-14

    This paper is divided into two parts: in the first part, the influence of solvate molecules on the magnetic properties of spin crossover salts of [Fe(bpp)(2)][Cr(L)(ox)(2)]ClO(4) x nS (bpp = 2,6-bis(pyrazol-3yl)pyridine; L = 2,2'-bipyridine (bpy) or 1,10-phenanthroline (phen); ox = oxalate dianion; S = solvent) is analyzed. The second part is devoted to the photomagnetic properties of the previously reported [Fe(bpp)(2)][Cr(L)(ox)(2)](2) family of compounds. The study describes the crystal structure, differential scanning calorimetry (DSC) and magnetic properties of [Fe(bpp)(2)][Cr(bpy)(ox)(2)]ClO(4) x EtOH x 4 H(2)O (1) and [Fe(bpp)(2)][Cr(phen)(ox)(2)]ClO(4) x 1.5 EtOH x 4 H(2)O (2). Both salts are high-spin (HS) compounds. Desolvation of 1 yields a material exhibiting a gradual spin crossover that involves 50% of the Fe(2+) cations. Rehydration of this desolvated salt induces a significant increase in the low-spin (LS) population. Desolvation of 2 affords a material showing a more abrupt spin crossover with thermal hysteresis (T(1/2)(increasing) = 286 K and T(1/2)(decreasing) = 273 K). This material is not very sensitive to rehydration. The anhydrous compounds [Fe(bpp)(2)][Cr(bpy)(ox)(2)](2) (3) and [Fe(bpp)(2)][Cr(phen)(ox)(2)](2) (4) display some quantitative photomagnetic conversion with T(LIESST) values of 41 and 51 K, respectively. Kinetic parameters governing the photo-induced HS-LS relaxation process have been determined and used to reproduce the T(LIESST) curves.

  4. Blocking S1P interaction with S1P1 receptor by a novel competitive S1P1-selective antagonist inhibits angiogenesis

    International Nuclear Information System (INIS)

    Fujii, Yasuyuki; Ueda, Yasuji; Ohtake, Hidenori; Ono, Naoya; Takayama, Tetsuo; Nakazawa, Kiyoshi; Igarashi, Yasuyuki; Goitsuka, Ryo

    2012-01-01

    Highlights: ► The effect of a newly developed S1P 1 -selective antagonist on angiogenic responses. ► S1P 1 is a critical component of VEGF-related angiogenic responses. ► S1P 1 -selective antagonist showed in vitro activity to inhibit angiogenesis. ► S1P 1 -selective antagonist showed in vivo activity to inhibit angiogenesis. ► The efficacy of S1P 1 -selective antagonist for anti-cancer therapies. -- Abstract: Sphingosine 1-phosphate receptor type 1 (S1P 1 ) was shown to be essential for vascular maturation during embryonic development and it has been demonstrated that substantial crosstalk exists between S1P 1 and other pro-angiogenic growth factors, such as vascular endothelial growth factor (VEGF) and basic fibroblast growth factor. We developed a novel S1P 1 -selective antagonist, TASP0277308, which is structurally unrelated to S1P as well as previously described S1P 1 antagonists. TASP0277308 inhibited S1P- as well as VEGF-induced cellular responses, including migration and proliferation of human umbilical vein endothelial cells. Furthermore, TASP0277308 effectively blocked a VEGF-induced tube formation in vitro and significantly suppressed tumor cell-induced angiogenesis in vivo. These findings revealed that S1P 1 is a critical component of VEGF-related angiogenic responses and also provide evidence for the efficacy of TASP0277308 for anti-cancer therapies.

  5. Structure and magnetic properties of Gd2Co17-xCr x (1.17 ≤ x ≤ 3.0) compounds

    International Nuclear Information System (INIS)

    Fuquan, B.; Tegus, O.; Dagula, W.; Brueck, E.; Klaasse, J.C.P.; Buschow, K.H.J.

    2007-01-01

    The structure and magnetic properties of Gd 2 Co 17-x Cr x (1.17 ≤ x ≤ 3.0) compounds have been investigated by means of X-ray diffraction (XRD) and magnetization measurements. The powder X-ray diffraction patterns show that all samples crystallize as a single phase with the rhombohedral Th 2 Zn 17 -type structure. The lattice parameters a and the unit cell volume V increases slightly with increasing Cr content, but the c parameter varies in a less simple way with increasing Cr content. The X-ray diffraction patterns of the magnetically aligned samples show that all compounds investigated have uniaxial anisotropy. Spin reorientation phenomena occur in all of the compounds. The Curie temperature T C , the spin reorientation temperature T sr , the spontaneous magnetization M 0 and the saturation magnetization M s decrease with the increasing Cr content. The anisotropy constant K 1 and the anisotropy field B a of the compounds at room temperature reach a maximum for x = 1.76. The M 0 and M s increase with increasing temperature from 5 K to 300 K. The easy-axis anisotropy of all compounds changes to easy-plane anisotropy at low temperatures and the spin reorientation phenomena are more pronounced for low Cr concentration

  6. The mercury chromates Hg6Cr2O9 and Hg6Cr2O10-Preparation and crystal structures, and thermal behaviour of Hg6Cr2O9

    International Nuclear Information System (INIS)

    Weil, Matthias; Stoeger, Berthold

    2006-01-01

    The basic mercury(I) chromate(VI), Hg 6 Cr 2 O 9 (=2Hg 2 CrO 4 .Hg 2 O), has been obtained under hydrothermal conditions (200deg. C, 5 days) in the form of orange needles as a by-product from reacting elemental mercury and K 2 Cr 2 O 7 . Hydrothermal treatment of microcrystalline Hg 6 Cr 2 O 9 in demineralised water at 200deg. C for 3 days led to crystal growth of red crystals of the basic mercury(I, II) chromate(VI), Hg 6 Cr 2 O 10 (=2Hg 2 CrO 4 .2HgO). The crystal structures were solved and refined from single crystal X-ray data sets. Hg 6 Cr 2 O 9 : space group P2 1 2 1 2 1 , Z=4, a=7.3573(12), b=8.0336(13), c=20.281(3)A, 3492 structure factors, 109 parameters, R[F 2 >2σ(F 2 )]=0.0371, wR(F 2 all)=0.0517; Hg 6 Cr 2 O 10 : space group Pca2 1 , Z=4, a=11.4745(15), b=9.4359(12), c=10.3517(14)A, 3249 structure factors, 114 parameters, R[F 2 >2σ(F 2 )]=0.0398, wR(F 2 all)=0.0625. Both crystal structures are made up of an intricate mercury-oxygen network, subdivided into single building blocks [O-Hg-Hg-O] for the mercurous compound, and [O-Hg-Hg-O] and [O-Hg-O] for the mixed-valent compound. Hg 6 Cr 2 O 9 contains three different Hg 2 2+ dumbbells, whereas Hg 6 Cr 2 O 10 contains two different Hg 2 2+ dumbbells and two Hg 2+ cations. The Hg I -Hg I distances are characteristic and range between 2.5031(15) and 2.5286(9)A. All Hg 2 2+ groups exhibit an unsymmetrical oxygen environment. The oxygen coordination of the Hg 2+ cations is nearly linear with two tightly bonded O atoms at distances around 2.07A. For both structures, the chromate(VI) anions reside in the vacancies of the Hg-O network and deviate only slightly from the ideal tetrahedral geometry with average Cr-O distances of ca. 1.66A. Upon heating at temperatures above 385deg. C, Hg 6 Cr 2 O 9 decomposes in a four-step mechanism with Cr 2 O 3 as the end-product at temperatures above 620 deg. C

  7. Adsorption of 1,2-dichlorobenzene and 1,2,4-trichlorobenzene in nano- and microsized crystals of MIL-101(Cr): static and dynamic gravimetric studies.

    Science.gov (United States)

    Bullot, Laetitia; Vieira-Sellaï, Ludivine; Chaplais, Gérald; Simon-Masseron, Angélique; Daou, Toufic Jean; Patarin, Joël; Fiani, Emmanuel

    2017-12-01

    This work aims to highlight the promising adsorption capacity and kinetic of (poly)chlorobenzene pollutants in the hybrid MIL-101(Cr) type material for technological uses in industrial waste exhaust decontamination. The influence of the MIL-101(Cr) crystal size (nano- and microcrystals) on the adsorption behavior was studied in static and dynamic modes. For this purpose, crystals of MIL-101(Cr) in nano- and micrometric sizes were synthesized and fully characterized. Their sorption properties regarding 1,2-dichlorobenzene were examined using gravimetric method in dynamic (p/p° = 0.5) and static (p/p° = 1) modes at room temperature. 1,2,4-trichlorobenzene adsorption was only performed under static mode because of its too low vapor pressure. 1,2-dichlorobenzene and 1,2,4-trichlorobenzene were used to mimic 2,3-dichlorodibenzo-p-dioxin and 1,2,3,4-tetrachlorodibenzo-p-dioxin, respectively, and more largely dioxin compounds. Adsorptions of these probes were successfully carried out in nano- and microcrystals of MIL-101(Cr). Indeed, in static mode (p/p° = 1) and at room temperature, nanocrystals adsorb 2266 molecules of 1,2-dichlorobenzene and 2093 molecules of 1,2,4-trichlorobenzene per unit cell, whereas microcrystals adsorb 1871 molecules of 1,2-dichlorobenzene and 1631 molecules of 1,2,4-trichlorobenzene per unit cell. In dynamic mode, the 1,2-dichlorobenzene adsorbed amounts are substantially similar to those obtained in static mode. However, the adsorption kinetics are different because of a different scheme of diffusivity of the adsorbate between the two modes. To the best of our knowledge, these adsorption capacities of MIL-101(Cr) as adsorbent for polychlorobenzenes trapping have never been referenced. MIL-101(Cr) appears as a promising material for technological uses in industrial waste exhaust decontamination.

  8. Radioprotective effect of low doses of 2-(1-naphthylmethyl)-2-imidazoline alone or associated with phosphorothioates

    International Nuclear Information System (INIS)

    Laval, J.D.; Roman, V.; Fatome, M.; Laduranty, J.; Miginiac, L.; Lion, C.; Sentenac-Roumanou, H.

    1993-01-01

    In the mouse, the intraperitoneal injection of 2-(1-naphthylmethyl)-2-imidazoline has a radioprotective effect even at low doses. Its association with S-[2-(3-aminopropyl)aminoethyl] phosphorothioate (WR 2721) or S-[3-(3-methylaminopropyl)-aminopropyl]phosphorothioate (WR 151327) at low doses led to an enhancement of their respective radioprotective activities without any apparent side effects. These results strengthen the interest of this non-sulphur compound as a radioprotector

  9. A highly sensitive and selective detection of Cr(VI) and ascorbic acid based on nitrogen-doped carbon dots.

    Science.gov (United States)

    Zhang, Yuhua; Fang, Xian; Zhao, Hong; Li, Zengxi

    2018-05-01

    A highly sensitive and selective detection of hexavalent chromium (Cr(VI)) and ascorbic acid (AA) was proposed using nitrogen-doped carbon dots (N-CDs). In the absence of AA, the quantitative detection of Cr(VI) was realized through Cr(VI) acting as a quencher to quench the fluorescence of N-CDs by inner filter effect (IFE) and static quenching effect. Under the optimal conditions, the linear range for Cr(VI) detection was from 0.01 to 250μM with a detection limit of 5nM (S/N = 3). In the presence of AA, the fluorescence intensity could be rapidly enhanced compared with the fluorescence of N-CDs/Cr(VI) system since Cr(VI) can be reduced into trivalent chromium (Cr(III)) by AA. And a wide linear range for AA detection was obtained from 1 to 750μM. The detection limit was 0.3μM (S/N = 3). More importantly, this method can be successfully applied to the detection of Cr(VI) in real water samples, and AA in vitamins C tablets and human serum sample. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Al2 O3:Cr,Ni: a possible thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato; Ibarra S, Angel

    1996-01-01

    Results from a study on the thermoluminescent (Tl) emission from Al 2 O 3 :Cr,Ni are presented. The measurements were obtained for evaluation of the Al 2 O 3 :Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and β - ). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al 2 O 3 :Cr,Ni properties indicate that it could be used as a dosemeter. (author)

  11. Magnetic and transport properties of Cu1.05Cr0.89 Mg0.05O2 and Cu0.96Cr0.95 Mg0.05Mn0.04O2 films

    International Nuclear Information System (INIS)

    Xu Qingyu; Schmidt, Heidemarie; Zhou Shengqiang; Potzger, Kay; Helm, Manfred; Hochmuth, Holger; Lorenz, Michael; Meinecke, Christoph; Grundmann, Marius

    2008-01-01

    We prepared conductive, polycrystalline or amorphous Cu 1.05 Cr 0.89 Mg 0.05 O 2 films on a-plane sapphire substrates by pulsed laser deposition under different O 2 partial pressure and substrate temperature. Hall measurements were performed to study the majority carrier type in these films. Polycrystalline Cu 1.05 Cr 0.89 Mg 0.05 O 2 is n-type conducting at 290 K, while in amorphous Cu 1.05 Cr 0.89 Mg 0.05 O 2 the type of majority charge carriers changes from electrons to holes at around 270 K. Interestingly, the structure has little influence on the magnetic properties of the films. A clear antiferromagnetic to paramagnetic transition was observed in both polycrystalline and amorphous Cu 1.05 Cr 0.89 Mg 0.05 O 2 films at 25 K. Similar electrical properties to Cu 1.05 Cr 0.89 Mg 0.05 O 2 film were observed for Cu 0.96 Cr 0.95 Mg 0.05 Mn 0.04 O 2 in dependence on the structure, while only paramagnetic without antiferromagnetic ordering was observed down to 5 K. Large negative magnetoresistance of 27% at 20 K was observed at 6 T in amorphous Cu 1.05 Cr 0.89 Mg 0.05 O 2 film

  12. Modeling Tolerance Development for the Effect on Heart Rate of the Selective S1P1 Receptor Modulator Ponesimod.

    Science.gov (United States)

    Lott, Dominik; Lehr, Thorsten; Dingemanse, Jasper; Krause, Andreas

    2017-09-15

    Ponesimod is a selective sphingosine-1-phosphate-1 (S1P 1 ) receptor modulator currently under investigation for the treatment of multiple sclerosis. S1P receptor modulators reduce heart rate following treatment initiation. This effect disappears with repeated dosing, enabling development of innovative uptitration regimens to optimize patient safety. There are currently no published pharmacokinetic/pharmacodynamic models describing the heart rate reduction of S1P receptor modulators in humans. The model developed here provides quantification of this effect for ponesimod. A direct-effect I max model with estimated maximum reduction of 45%, tolerance development, and circadian variation best described this effect. The pooled data from nine clinical studies enabled characterization of interindividual variability. The model was used to simulate different treatment regimens to compare the effect of high initial doses vs. gradual uptitration with respect to the occurrence of bradycardia. The results indicate a better safety profile when using gradual uptitration. The model allows studying dosing regimens not clinically tested in silico. © 2017 American Society for Clinical Pharmacology and Therapeutics.

  13. Al{sub 2} O{sub 3}:Cr,Ni: a possible thermoluminescent dosemeter; Al{sub 2} O{sub 3}: Cr, Ni un posible dosimetro termoluminiscente

    Energy Technology Data Exchange (ETDEWEB)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Ibarra S, Angel [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain). Seccion Materiales para Fusion

    1997-12-31

    Results from a study on the thermoluminescent (Tl) emission from Al{sub 2} O{sub 3}:Cr,Ni are presented. The measurements were obtained for evaluation of the Al{sub 2} O{sub 3}:Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and {beta}{sup -}). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al{sub 2} O{sub 3}:Cr,Ni properties indicate that it could be used as a dosemeter. (author). 5 refs., 4 figs.

  14. New antiferromagnetic semiconductor CuCr1.5Sb0.5S4

    International Nuclear Information System (INIS)

    Kesler, Ya.A.; Koroleva, L.I.; Mikheev, M.G.; Odintsov, A.G.; Filimonov, D.S.

    1993-01-01

    New halcogenide compound with spinel-antiferromagnetic semiconductor CuCr 1.5 Sb 0.5 S 4 are obtained and studied for the first time. Magnetic properties of this compound, namely, magnetization linear dependence, maximum on PHI(T) curve in the low-temperature area and realization of the Curie-Weis law for paramagnetic susceptibility with negative paramagnetic temperature testiby to the fact that this compound is antiferromagnetic

  15. Review of time-dependent fatigue behavior and life prediction for 2 1/4 Cr-1 Mo steel

    International Nuclear Information System (INIS)

    Booker, M.K.; Majumdar, S.

    1982-01-01

    Available data on creep-fatigue life and fracture behavior of 2 1/4 Cr-1 Mo steel are reviewed. Whereas creep-fatigue interaction is important for Type 304 stainless steel, oxidation effects appear to dominate the time-dependent fatigue behavior of 2 1/4 Cr-1 Mo steel. Four of the currently available predictive methods - the Linear Damage Rule, Frequency Separation Equation, Strain Range Partitioning Equation, and Damage Rate Equation - are evaluated for their predictive capability. Variations in the parameters for the various predictive methods with temperature, heat of material, heat treatment, and environment are investigated. Relative trends in the lives predicted by the various methods as functions of test duration, waveshape, etc., are discussed. The predictive methods will need modification in order to account for oxidation and aging effects in the 2 1/4 Cr-1 Mo steel. Future tests that will emphasize the difference between the various predictive methods are proposed

  16. Characterization of Cr-O cermet solar selective coatings deposited by using direct-current magnetron sputtering technology

    International Nuclear Information System (INIS)

    Lee, Kil Dong

    2006-01-01

    Cr-O (Cr-CrO) cermet solar selective coatings with a double cermet layer film structure were prepared by using a special direct-current (dc) magnetron sputtering technology. The typical film structure from the surface to the bottom substrate was an Al 2 O 3 anti-reflection layer on a double Cr-O cermet layer on an Al metal infrared reflection layer. The deposited Cr-O cermet solar selective coating had an absorptance of α = 0.93 - 0.95 and an emittance of ε = 0.09 - 0.10(100 .deg. C). The absorption layers of the Cr-O cermet coatings deposited on glass and silicon substrates were identified as being amorphous by using X-ray diffraction (XRD). Atomic force microscopy (AFM) showed that Cr-O cermet layers were very smooth and that their grain sizes were very small. The result of thermal stability test showed that the Cr-O cermet solar selective coating was stable for use at temperatures of under 400 .deg. C.

  17. SU-F-T-299: An Experimental 2D Computed Radiography (CR) Dosimeter for IMRT. Are In-Field Measurements Affected by the Low Energy Photon Overresponse?

    Energy Technology Data Exchange (ETDEWEB)

    Crijns, W [University Hospital Leuven, Leuven (Belgium); Vandenbroucke, D; Leblans, P [Agfa Healthcare N.V., Mortsel (Belgium); Depuydt, T

    2016-06-15

    Purpose: Computed Radiography (CR) dosimetry could offer film dosimetry resolution and flexibility but with reusability and instantaneous processing. For an experimental CR-plate, designed for radiotherapy (Zeff=18), CR’s typical out-of-field over-response to low energy photons was previously reduced to 8%. The present work assesses the impact of the residual over-response when open-fields are combined or when intensity modulated fields are used. Methods: Agfa Healthcare’s experimental CRplate was scanned and erased 4min after each irradiation using a flying-spot CR-15-X-engine based reader, which was adapted for radiotherapy dosimetry. A CR-plate specific calibration and uniformity correction was used.For open-fields two abutting half beams (5×10cm{sup 2}) captured out-offield and in-field doses in a single image. Additionally, both half beams were measured individually as well as a 3×18Gy open-field SBRT-lung treatment. For intensity modulated fields standard test patterns (Chair and Pyramid) and a clinical 5×5Gy rectal VMAT plan were captured. All measurements were compared to the corresponding dose calculations. Results: For open-fields the out-of-field overdose was clearly larger than the in-field overdose (10% vs. 4%). The sum of the individual measurements corresponded well with the combined measurement (dose difference, ΔD<−2.2%). The SBRT case had no overdose in the high dose region; ΔD=−5.6%±3.3%, the deviation was attributed to CR-fading effects (−0.3%/min) which were not corrected for.Compared to open-fields, intensity modulated deliveries had a further increased over-response out-offield (ΔD=+58% to +125% [Chair] +43% [Pyramid]), due to the increased amount of low energy photons for IMRT. However, this effect was not measured in-field where even decreased dose signals were observed (ΔD=−0.3% to +2.25% [Chair], −4.5% to −0.1% [Pyramid]). The rectal VMAT treatment had a dose difference +2.4%±6.0%. The in-field deviations were

  18. Detection of Hydrogen Sulphide Gas Sensor Based Nanostructured Ba2CrMoO6 Thick Films

    Directory of Open Access Journals (Sweden)

    A. V. Kadu

    2007-11-01

    Full Text Available Nanocrystalline pure and doped Ba2CrMoO6, having an average crystallite size of 40 nm were synthesized by the sol-gel citrate method. Structural and gas-sensing characteristics were performed by using X-ray diffraction (XRD and sensitivity measurements. The gas sensing properties to reducing gases like Hydrogen sulphide (H2S, liquefied petroleum gas (LPG, carbon monoxide (CO and hydrogen gas (H2 were also discussed. The maximum sensitivity was obtained for 5 wt % Ni doped Ba2CrMoO6 at an operating temperature 250oC for H2S gas. Pd incorporation over 5 wt% Ni doped Ba2CrMoO6 improved the sensitivity, selectivity, response time, and reduced the operating temperature from 250 to 200oC of the sensor for H2S gas. This sensor also shows good satiability.

  19. Synthesis of surface Cr (VI)-imprinted magnetic nanoparticles for selective dispersive solid-phase extraction and determination of Cr (VI) in water samples.

    Science.gov (United States)

    Qi, Xue; Gao, Shuang; Ding, Guosheng; Tang, An-Na

    2017-01-01

    A facile, rapid and selective magnetic dispersed solid-phase extraction (dSPE) method for the extraction and enrichment of Cr (VI) prior to flame atomic absorption spectrometry (AAS) was introduced. For highly selective and efficient extraction, magnetic Cr (VI)-imprinted nanoparticles (Fe 3 O 4 @ Cr (VI) IIPs) were prepared by hyphenating surface ion-imprinted with sol-gel techniques. In the preparation process, chromate (Cr(VI)) was used as the template ion; vinylimidazole and 3-aminopropyltriethoxysilane were selected as organic functional monomer and co-monomer respectively. Another reagent, methacryloxypropyltrimethoxysilane was adopted as coupling agent to form the stable covalent bonding between organic and inorganic phases. The effects of various parameters on the extraction efficiency, such as pH of sample solution, the amount of adsorbent, extraction time, the type and concentration of eluent were systematically investigated. Furthermore, the thermodynamic and kinetic properties of the adsorption process were studied to explore the internal adsorption mechanism. Under optimized conditions, the preconcentration factor, limit of detection and linear range of the established dSPE-AAS method for Cr (VI) were found to be 98, 0.29μgL -1 and 4-140μgL -1 , respectively. The developed method was also successfully applied to the analysis of Cr (VI) in different water samples with satisfactory results, proving its reliability and feasibility in real sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Microstructure and properties of nitrogen ion implantation/AlN/CrAlN/MoS{sub 2}-phenolic resin duplex coatings on magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Zhiwen [University of Science and Technology Liaoning, Anshan 114051 (China); Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714 (China); Chen, Qiang, E-mail: 2009chenqiang@163.com [Southwest Technique and Engineering Research Institute, Chongqing 400039 (China); Chen, Tian [Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714 (China); Gao, Xu; Yu, Xiaoguang; Song, Hua; Feng, Yongjun [University of Science and Technology Liaoning, Anshan 114051 (China)

    2015-06-15

    The novel nitrogen ion implantation/AlN/CrAlN/MoS{sub 2}-phenolic resin duplex coatings are fabricated on the AM60 magnesium alloys. The microstructure, tribological and electrochemical properties of the duplex coatings are characterized by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, nano-indenter, electrochemical corrosion and wear tester. These studies reveal that the MoS{sub 2}-phenolic resin coating has a two-phase microstructure crystalline MoS{sub 2} particles embedded in the amorphous phenolic resin matrix. The single-layer MoS{sub 2}-phenolic resin enhances the corrosion resistance of magnesium alloys, but shows poor wear resistance due to the low substrate's load bearing capacity. The addition of nitrogen ion implantation/AlN/CrAlN interlayer in the MoS{sub 2}-phenolic resin/substrate system greatly enhances the substrate's load bearing capacity. The AlN/CrAlN/MoS{sub 2}-phenolic resin duplex coating with a high load bearing capacity demonstrates super wear resistance (i.e., long wear life and low friction coefficient). In addition, the nitrogen ion implantation/AlN interlayer greatly depresses the effect of galvanic corrosion because its potential is close to that of the magnesium alloys, but the nitrogen ion implantation/AlN/CrAlN interlayer is inefficient in reducing the galvanic corrosion due to the large potential difference between the CrN phase and the substrate. As a result, the nitrogen ion implantation/AlN/MoS{sub 2}-phenolic resin duplex coating shows a better corrosion resistance compared to the nitrogen ion implantation/AlN/CrAlN/MoS{sub 2}-phenolic resin. - Highlights: • Ion implantation/AlN/CrAlN/MoS{sub 2}-phenolic resin duplex coatings were presented. • Ion implantation/AlN/CrAlN interlayer greatly enhanced the load bearing capacity. • Ion implantation/AlN interlayer greatly depressed the effect of galvanic corrosion. • The

  1. Magnetic phase diagram of Co(Cr1-xA lx) 2O4 (x = 0.0-1.0)

    Science.gov (United States)

    Padam, R.; Sarkar, T.; Mathieu, R.; Thota, S.; Pal, D.

    2017-08-01

    We report the role of Al substitution in the magnetic properties of spinel CoCr2O4 by means of temperature dependent dc and ac magnetization and heat capacity measurements. Various compositions (0.0 ≤ x ≤ 1.0) of polycrystalline Co(Cr1-xAlx)2O4 samples have been prepared by sol-gel processing and their crystal structure was investigated by X-ray diffraction which was found to crystallize in the normal cubic spinel structure. For x ≤ 0.1, the system exhibits multiple magnetic orderings (long range ferrimagnetic ordering TC, spin-spiral ordering TS, and lock-in transition TL), similar to that of the parent compound, CoCr2O4. However, all the compositions between x = 0.1 and 0.5 exhibit long range ferrimagnetic ordering below TC and also a short range order at low temperature. Spin-glass like ordering was noticed between x = 0.6 and 0.8 due to the diluted B-site occupancy, whereas the end compound CoAl2O4 (x = 1.0) shows antiferromagnetic behavior. On the basis of these results, we propose a magnetic phase diagram for the Co(Cr1-xAlx)2O4 series as a function of the Al content (x) and measuring temperature (T).

  2. Low-Dose Radiation Therapy (2 Gy × 2) in the Treatment of Orbital Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Fasola, Carolina E. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Jones, Jennifer C. [Vaccine Branch, Center for Cancer Research, National Cancer Institute, Bethesda, Maryland (United States); Huang, Derek D. [Department of Internal Medicine, University of California-Los Angeles Olive View, Sylmar, California (United States); Le, Quynh-Thu; Hoppe, Richard T. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Donaldson, Sarah S., E-mail: sarah2@stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California (United States)

    2013-08-01

    Purpose: Low-dose radiation has become increasingly used in the management of indolent non-Hodgkin lymphoma (NHL), but has not been studied specifically for cases of ocular adnexal involvement. The objective of this study is to investigate the effectiveness of low-dose radiation in the treatment of NHL of the ocular adnexa. Methods and Materials: We reviewed the records of 20 NHL patients with 27 sites of ocular adnexal involvement treated with low-dose radiation consisting of 2 successive fractions of 2 Gy at our institution between 2005 and 2011. The primary endpoint of this study is freedom from local relapse (FFLR). Results: At a median follow-up time of 26 months (range 7-92), the overall response rate for the 27 treated sites was 96%, with a complete response (CR) rate of 85% (n=23) and a partial response rate of 11% (n=3). Among all treated sites with CR, the 2-year FFLR was 100%, with no in-treatment field relapses. The 2-year freedom from regional relapse rate was 96% with 1 case of relapse within the ipsilateral orbit (outside of the treatment field). This patient underwent additional treatment with low-dose radiation of 4 Gy to the area of relapse achieving a CR and no evidence of disease at an additional 42 months of follow-up. Orbital radiation was well tolerated with only mild acute side effects (dry eye, conjunctivitis, transient periorbital edema) in 30% of treated sites without any reports of long-term toxicity. Conclusions: Low-dose radiation with 2 Gy × 2 is effective and well tolerated in the treatment of indolent NHL of the ocular adnexa with high response rates and durable local control with the option of reirradiation in the case of locoregional relapse.

  3. Low-Dose Radiation Therapy (2 Gy × 2) in the Treatment of Orbital Lymphoma

    International Nuclear Information System (INIS)

    Fasola, Carolina E.; Jones, Jennifer C.; Huang, Derek D.; Le, Quynh-Thu; Hoppe, Richard T.; Donaldson, Sarah S.

    2013-01-01

    Purpose: Low-dose radiation has become increasingly used in the management of indolent non-Hodgkin lymphoma (NHL), but has not been studied specifically for cases of ocular adnexal involvement. The objective of this study is to investigate the effectiveness of low-dose radiation in the treatment of NHL of the ocular adnexa. Methods and Materials: We reviewed the records of 20 NHL patients with 27 sites of ocular adnexal involvement treated with low-dose radiation consisting of 2 successive fractions of 2 Gy at our institution between 2005 and 2011. The primary endpoint of this study is freedom from local relapse (FFLR). Results: At a median follow-up time of 26 months (range 7-92), the overall response rate for the 27 treated sites was 96%, with a complete response (CR) rate of 85% (n=23) and a partial response rate of 11% (n=3). Among all treated sites with CR, the 2-year FFLR was 100%, with no in-treatment field relapses. The 2-year freedom from regional relapse rate was 96% with 1 case of relapse within the ipsilateral orbit (outside of the treatment field). This patient underwent additional treatment with low-dose radiation of 4 Gy to the area of relapse achieving a CR and no evidence of disease at an additional 42 months of follow-up. Orbital radiation was well tolerated with only mild acute side effects (dry eye, conjunctivitis, transient periorbital edema) in 30% of treated sites without any reports of long-term toxicity. Conclusions: Low-dose radiation with 2 Gy × 2 is effective and well tolerated in the treatment of indolent NHL of the ocular adnexa with high response rates and durable local control with the option of reirradiation in the case of locoregional relapse

  4. Corrosion critique of the 2 1/4 Cr--1 Mo steel for LMFBR steam generation system applications

    International Nuclear Information System (INIS)

    Zima, G.E.

    1977-07-01

    The unstabilized ferritic steel of nominal composition, 2 1 / 4 Cr-1Mo, has been proposed for critical structural assignments in LMFBR powerplants, specifically: the tubing, tubesheet and shell of the evaporator and superheater components. The interest in this steel has been based on a presumably favorable general corrosion property spectrum, acceptable mechanical properties and fabricability, and certain economies associated with the low alloy content. This report is an attempt at a general corrosion assessment for the 2 1 / 4 Cr-1Mo steel and an identification of corrosion problem areas potential to this steel from the sodium and water/steam systems of the proposed working environment. There is a considerable area of uncertainty in the sodium-side response of 2 1 / 4 Cr-1Mo steel, centered in the loss and redisposition of carbon during long-term exposure to sodium of various impurity backgrounds. It is submitted that present evidence relating to the water/steam-side corrosion behavior of the 2 1 / 4 Cr-1Mo steel, under nominal and conceivable perturbed environmental conditions, constitutes the principal concern for the proposed LMFBR powerplant applications of this steel. It is suggested that this unfavorable corrosion aspect represents an inherent limitation of the low alloy content of this steel, probably largely independent of melting and processing recourses, and it is a sufficient basis to question the incentive for a continuation of the collateral studies of this steel for the proposed LMFBR steam generation system assignments

  5. Sphingosine-1-Phosphate (S1P) Lyase Inhibition Causes Increased Cardiac S1P Levels and Bradycardia in Rats.

    Science.gov (United States)

    Harris, Christopher M; Mittelstadt, Scott; Banfor, Patricia; Bousquet, Peter; Duignan, David B; Gintant, Gary; Hart, Michelle; Kim, Youngjae; Segreti, Jason

    2016-10-01

    Inhibition of the sphingosine-1-phosphate (S1P)-catabolizing enzyme S1P lyase (S1PL) elevates the native ligand of S1P receptors and provides an alternative mechanism for immune suppression to synthetic S1P receptor agonists. S1PL inhibition is reported to preferentially elevate S1P in lymphoid organs. Tissue selectivity could potentially differentiate S1PL inhibitors from S1P receptor agonists, the use of which also results in bradycardia, atrioventricular block, and hypertension. But it is unknown if S1PL inhibition would also modulate cardiac S1P levels or cardiovascular function. The S1PL inhibitor 6-[(2R)-4-(4-benzyl-7-chlorophthalazin-1-yl)-2-methylpiperazin-1-yl]pyridine-3-carbonitrile was used to determine the relationship in rats between drug concentration, S1P levels in select tissues, and circulating lymphocytes. Repeated oral doses of the S1PL inhibitor fully depleted circulating lymphocytes after 3 to 4 days of treatment in rats. Full lymphopenia corresponded to increased levels of S1P of 100- to 1000-fold in lymph nodes, 3-fold in blood (but with no change in plasma), and 9-fold in cardiac tissue. Repeated oral dosing of the S1PL inhibitor in telemeterized, conscious rats resulted in significant bradycardia within 48 hours of drug treatment, comparable in magnitude to the bradycardia induced by 3 mg/kg fingolimod. These results suggest that S1PL inhibition modulates cardiac function and does not provide immune suppression with an improved cardiovascular safety profile over fingolimod in rats. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  6. Magnetic interactions in HoCr{sub 1-x}Fe{sub x}O{sub 3} (x = 0, 0.2) investigated by neutron powder diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinzhi, E-mail: liuxinzhi1984.cn@163.com [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China); Hao, Lijie; Ma, Xiaobai [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China); Wang, Chin-Wei [Neutron Group, National Synchrotron Radiation Research Center, Hsinchu 30077, Taiwan (China); Klose, Frank [Australian Nuclear Science and Technology Organization, Lucas Heights, New South Wales 2234 (Australia); Department of Physics and Materials Science, The City University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Liu, Yuntao, E-mail: ytliu@ciae.ac.cn [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China); Sun, Kai; Li, Yuqing [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China); Chen, Dongfeng, E-mail: dongfeng@ciae.ac.cn [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China)

    2017-07-01

    Highlights: • The temperature dependent magnetism of HoCr{sub 1-x}Fe{sub x}O{sub 3} (x = 0, 0.2) were investigated by neutron diffraction. • Cr{sup 3+} moment follows a mean field theory while Ho{sup 3+} follows a spin 1/2 model. • An magneto-elastic strain was observed accompanying with the ordering of Cr{sup 3+}. - Abstract: The temperature dependent magnetism of Fe-doped rare earth orthochromite HoCr{sub 1-x}Fe{sub x}O{sub 3}(x = 0, 0.2) was investigated by neutron powder diffraction. It is found that the magnetism of Cr(Fe){sup 3+} can be well understood within mean field theory, while the ordering of Ho{sup 3+} was induced by the Cr(Fe){sup 3+} sublattice and can be satisfyingly described by an effective S = 1/2 model. The absences of both the most common G{sub x}F{sub z} configuration of Cr{sup 3+} and the ordering of Ho{sup 3+} caused by Ho-Ho interaction evidence a strong Ho{sup 3+}-Cr{sup 3+} interaction which dominates this system. On the other hand, a remarkable magnetoelastic strain was observed accompanying the Cr(Fe){sup 3+} ordering. An analysis based on the equation of state with a Grüneisen approximation was performed and revealed magnetic origin of this strain.

  7. Development of a real-time dose monitor with Cr-doped Gd.sub.3./sub.Ga.sub.5./sub.O.sub.12./sub. infrared scintillator

    Czech Academy of Sciences Publication Activity Database

    Kurosawa, S.; Yamaji, A.; Kochurikhin, V.V.; Ivanov, M.; Pejchal, Jan; Murakami, R.; Shoji, Y.; Ohashi, Y.; Yokota, Y.; Kamada, K.; Yoshikawa, A.

    2017-01-01

    Roč. 106, Nov (2017), s. 187-191 ISSN 1350-4487 Institutional support: RVO:68378271 Keywords : scintillator * infrared * Cr:Gd3Ga5O12 * dose monitor Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.442, year: 2016

  8. Study of half-metallic ferromagnetism and elastic properties of Cd{sub 1-x}Cr{sub x}Z (Z=S, Se)

    Energy Technology Data Exchange (ETDEWEB)

    Rani, Anita [Guru Nanak College for Girls, Sri Muktsar Sahib, Punjab (India); Kumar, Ranjan [Panjab University Chandigarh, Department of Physics, Chandigarh (India)

    2016-12-15

    We have studied the structural, electronic and magnetic properties of Cd{sub 1-x}Cr{sub x}S and Cd{sub 1-x}Cr{sub x}Se diluted magnetic semiconductors in zinc blende (B3) phase at x = 0.25, 0.125 and 0.0625. The calculations have been performed using DFT (density functional theory) as implemented in SIESTA code using LDA (local density approximation) as exchange-correlation (XC) potential. Study of band structures and DOS (density of states) shows HMF (half-metallic ferromagnetic) nature of Cd{sub 1-x}Cr{sub x}S and Cd{sub 1-x}Cr{sub x}Se alloys. The calculated values of s-d exchange constant Nα and p-d exchange constant Nβ show the magnetic behavior of these compounds. Moreover, both DMSs retain their half-metallic nature at 0.25, 0.125 and 0.0625 concentrations with 100% spin polarization at Fermi level (E{sub F}). Total magnetic moment of these compounds is due to 3d states of Cr atom and also existence of small induced magnetic moment on other non-magnetic atoms as well. HM robustness is also calculated as a function of lattice constants. (orig.)

  9. Photocatalytic applications of Cr{sub 2}S{sub 3} synthesized from single and multi-source precursors

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Wajid [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Badshah, Amin, E-mail: aminbadshah@qau.edu.pk [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Hussain, Raja Azadar; Imtiaz-ud-Din [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Aleem, Muhammad Adeel [The Pakistan Institute of Engineering and Applied Sciences (PIEAS) (Pakistan); Bahadur, Ali [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Iqbal, Shahid [School of Chemistry and Chemical Engineering, University of Chinese Academy of Sciences, Beijing, 100049 (China); Farooq, Muhammad Umar; Ali, Hassan [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan)

    2017-06-15

    Most of the material research work is pertinent to the synthesis of transition-metal sulfides nanoparticles but here the studies are limited to the synthesis of chromium sulfide. However, the preparation method, presented in this work, may be extended to other metal chalcogenides nanoparticles for various potential applications. The ligand (precursor), 1-(2-chloro-4-nitrophenyl)-3,3-chlorobenzoyl and Cr{sub 2}S{sub 3} have been synthesized initially from single source precursor and then from multi source precursors. The target was to alter the morphologies of nanomaterial while altering the synthetic route and that was successfully achieved. Chromium sulfide nano-rods were synthesized using single source precursors while nanoparticles were fabricated using multi source precursors. Characterization were carried out through {sup 1}H and {sup 13}C NMR, scanning electron microscopy (SEM), transmission electron microscopy (TEM), powder X-ray diffraction microscopy (PXRD), energy dispersive X-ray spectroscopy (EDX), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and high resolution transmission electron microscopy (HRTEM). Our objective is to change the morphologies by changing the synthetic route so that is why further applications were done only for multi-source product, denying single source product. The metal sulfides nanoparticles exhibit higher activity than their bulk material for the photocatalytic degradation of organic dyes under visible-light irradiation. So, photocatalytic activity was successfully achieved under direct sunlight against five different cationic and anionic organic dyes including malachite green (MG), methylene blue (MB), rhodamine B (RhB), methyl violet (MV) and methyl orange (MO). These organic dyes MV, MG, MB, and RB were almost diminished or decolorized by Cr{sub 2}S{sub 3} within 110, 90, 100, and 130, minutes, respectively expect MO. - Highlights: • Synthesis of Cr{sub 2}S{sub 3} from single and multisource precursors is

  10. Low-dose aspirin, non-steroidal anti-inflammatory drugs, selective COX-2 inhibitors and breast cancer recurrence

    DEFF Research Database (Denmark)

    Cronin-Fenton, Deirdre P; Heide-Jørgensen, Uffe; Ahern, Thomas P

    2016-01-01

    BACKGROUND: Aspirin, nonsteroidal anti-inflammatory drugs (NSAIDs), and selective COX-2 inhibitors may improve outcomes in breast cancer patients. We investigated the association of aspirin, NSAIDs, and use of selective COX-2 inhibitors with breast cancer recurrence. METHODS: We identified incident...... stage I-III Danish breast cancer patients in the Danish Breast Cancer Cooperative Group registry, who were diagnosed during 1996-2008. Prescriptions for aspirin (>99% low-dose aspirin), NSAIDs, and selective COX-2 inhibitors were ascertained from the National Prescription Registry. Follow-up began....... RESULTS: We identified 34,188 breast cancer patients with 233,130 person-years of follow-up. Median follow-up was 7.1 years; 5,325 patients developed recurrent disease. Use of aspirin, NSAIDs, or selective COX-2 inhibitors was not associated with the rate of recurrence (HRadjusted aspirin = 1.0, 95% CI...

  11. The influence of heating rate on reheat-cracking in a commercial 2 1/4Cr1Mo steel

    International Nuclear Information System (INIS)

    Hippsley, C.A.

    1983-03-01

    The effects of elevated heating rate on stress-relief cracking in a commercial 2 1/4 Cr1Mo steel have been investigated. A SEN bend-specimen stress-relaxation test was used to assess reheat cracking susceptibility and fracture mechanisms for an initial post-weld heating rate of 1000 Kh - 1 . Two factors controlling the influence of heating rate on the final severity of cracking were identified, i.e. the rate of stress-relaxation with respect to temperature, and the time available for crack-growth. The factors were found to counteract each other, but in the case of commercial 2 1/4 Cr1Mo steel, the crack-growth factor outweighed the relaxation factor, resulting in a reduction in the propensity to stress-relief cracking at the elevated heating rate. However, by reference to the results of a separate investigation concerning A508/2 MnMoNiCr steel it was demonstrated that the balance between these two factors may be reversed in other alloy systems, with the consequence that reheat cracking is exacerbated by increasing the initial heating rate. A computer model was addressed to the stress-relaxation test conditions using data from the commercial 2 1/4 Cr1Mo steel. The model predictions exhibited reasonable agreement with experimental test results for both 100 Kh - 1 and 1000 Kh - 1 heating rates. (author)

  12. Does NGAL reduce costs? A cost analysis of urine NGAL (uNGAL) & serum creatinine (sCr) for acute kidney injury (AKI) diagnosis.

    Science.gov (United States)

    Parikh, Amay; Rizzo, John A; Canetta, Pietro; Forster, Catherine; Sise, Meghan; Maarouf, Omar; Singer, Eugenia; Elger, Antje; Elitok, Saban; Schmidt-Ott, Kai; Barasch, Jonathon; Nickolas, Thomas L

    2017-01-01

    Urine neutrophil gelatinase-associated lipocalin (uNGAL) is a sensitive and specific diagnostic test for acute kidney injury (AKI) in the Emergency Department (ED), but its economic impact has not been investigated. We hypothesized that uNGAL used in combination with serum creatinine (sCr) would reduce costs in the management of AKI in patients presenting to the ED in comparison to using sCr alone. A cost simulation model was developed for clinical algorithms to diagnose AKI based on sCr alone vs. uNGAL plus sCr (uNGAL+sCr). A cost minimization analysis was performed to determine total expected costs for patients with AKI. uNGAL test characteristics were validated with eight-hundred forty-nine patients with sCr1.5 from a completed study of 1635 patients recruited from EDs at two U.S. hospitals from 2007-8. Biomarker test, AKI work-up, and diagnostic imaging costs were incorporated. For a hypothetical cohort of 10,000 patients, the model predicted that the expected costs were $900 per patient (pp) in the sCr arm and $950 in the uNGAL+sCr arm. uNGAL+sCr resulted in 1,578 fewer patients with delayed diagnosis and treatment than sCr alone (2,013 vs. 436 pts) at center 1 and 1,973 fewer patients with delayed diagnosis and treatment than sCr alone at center 2 (2,227 vs. 254 patients). Although initial evaluation costs at each center were $50 pp higher in with uNGAL+sCr, total costs declined by $408 pp at Center 1 and by $522 pp at Center 2 due to expected reduced delays in diagnosis and treatment. Sensitivity analyses confirmed savings with uNGAL + sCr for a range of cost inputs. Using uNGAL with sCr as a clinical diagnostic test for AKI may improve patient management and reduce expected costs. Any cost savings would likely result from avoiding delays in diagnosis and treatment and from avoidance of unnecessary testing in patients given a false positive AKI diagnosis by use of sCr alone.

  13. Does NGAL reduce costs? A cost analysis of urine NGAL (uNGAL & serum creatinine (sCr for acute kidney injury (AKI diagnosis.

    Directory of Open Access Journals (Sweden)

    Amay Parikh

    Full Text Available Urine neutrophil gelatinase-associated lipocalin (uNGAL is a sensitive and specific diagnostic test for acute kidney injury (AKI in the Emergency Department (ED, but its economic impact has not been investigated. We hypothesized that uNGAL used in combination with serum creatinine (sCr would reduce costs in the management of AKI in patients presenting to the ED in comparison to using sCr alone.A cost simulation model was developed for clinical algorithms to diagnose AKI based on sCr alone vs. uNGAL plus sCr (uNGAL+sCr. A cost minimization analysis was performed to determine total expected costs for patients with AKI. uNGAL test characteristics were validated with eight-hundred forty-nine patients with sCr1.5 from a completed study of 1635 patients recruited from EDs at two U.S. hospitals from 2007-8. Biomarker test, AKI work-up, and diagnostic imaging costs were incorporated.For a hypothetical cohort of 10,000 patients, the model predicted that the expected costs were $900 per patient (pp in the sCr arm and $950 in the uNGAL+sCr arm. uNGAL+sCr resulted in 1,578 fewer patients with delayed diagnosis and treatment than sCr alone (2,013 vs. 436 pts at center 1 and 1,973 fewer patients with delayed diagnosis and treatment than sCr alone at center 2 (2,227 vs. 254 patients. Although initial evaluation costs at each center were $50 pp higher in with uNGAL+sCr, total costs declined by $408 pp at Center 1 and by $522 pp at Center 2 due to expected reduced delays in diagnosis and treatment. Sensitivity analyses confirmed savings with uNGAL + sCr for a range of cost inputs.Using uNGAL with sCr as a clinical diagnostic test for AKI may improve patient management and reduce expected costs. Any cost savings would likely result from avoiding delays in diagnosis and treatment and from avoidance of unnecessary testing in patients given a false positive AKI diagnosis by use of sCr alone.

  14. Dose distribution perturbation due to a Co-Cr-Mo prosthesis; Perturbacion introducida en la distribucion de dosis por una protesis de Co-Cr-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-07-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  15. Unified calculations of the optical band positions and EPR g factors for NaCrS2 crystal

    International Nuclear Information System (INIS)

    Mei, Yang; Zheng, Wen-Chen; Zhang, Lin

    2014-01-01

    Six optical band positions and EPR g factors g || , g ⊥ for the trigonal Cr 3+ octahedral clusters in NaCrS 2 crystal are calculated together through the complete diagonalization (of energy matrix) method based on the two-spin–orbit-parameter model, where besides the contribution due to the spin–orbit parameter of central d n ion in the conventional crystal-field theory, the contribution due to the spin–orbit parameter of ligand ion via the covalence effect is also considered. In the calculations, the crystal-field parameters B kl are obtained from the superposition model with the structural data of Cr 3+ octahedral clusters in NaCrS 2 crystal measured exactly by the X-ray diffraction method. The calculated optical and EPR spectral data are in a reasonable agreement with the observed values. So, the reliability of the superposition model in the studies of crystal-field parameters for d n ions in crystals is confirmed, and the complete diagonalization (of energy matrix) method based on the two-spin–orbit-model is effective in the unified calculations of optical and EPR spectral data for d n ions in crystals. - Highlights: • Six optical band positions and g factors g || , g ⊥ of NaCrS 2 are calculated together. • Calculation is using the complete diagonalization (of energy matrix) method. • The diagonalization method is based on the two-spin–orbit-parameter model. • Reliability of superposition model in the studies of CF parameters is confirmed

  16. Blocking S1P interaction with S1P{sub 1} receptor by a novel competitive S1P{sub 1}-selective antagonist inhibits angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Yasuyuki, E-mail: y.fujii@po.rd.taisho.co.jp [Department of Molecular Function and Pharmacology Laboratories, Taisho Pharmaceutical Co. Ltd., 1-403 Saitama, Saitama 331-9530 (Japan); Ueda, Yasuji; Ohtake, Hidenori; Ono, Naoya; Takayama, Tetsuo; Nakazawa, Kiyoshi [Department of Molecular Function and Pharmacology Laboratories, Taisho Pharmaceutical Co. Ltd., 1-403 Saitama, Saitama 331-9530 (Japan); Igarashi, Yasuyuki [Laboratory of Biomembrane and Biofunctional Chemistry, Hokkaido University, Sapporo, Hokkaido 060-0812 (Japan); Goitsuka, Ryo [Division of Development and Aging, Research Institute for Biological Sciences, Tokyo University of Science, Noda, Chiba 278-0022 (Japan)

    2012-03-23

    Highlights: Black-Right-Pointing-Pointer The effect of a newly developed S1P{sub 1}-selective antagonist on angiogenic responses. Black-Right-Pointing-Pointer S1P{sub 1} is a critical component of VEGF-related angiogenic responses. Black-Right-Pointing-Pointer S1P{sub 1}-selective antagonist showed in vitro activity to inhibit angiogenesis. Black-Right-Pointing-Pointer S1P{sub 1}-selective antagonist showed in vivo activity to inhibit angiogenesis. Black-Right-Pointing-Pointer The efficacy of S1P{sub 1}-selective antagonist for anti-cancer therapies. -- Abstract: Sphingosine 1-phosphate receptor type 1 (S1P{sub 1}) was shown to be essential for vascular maturation during embryonic development and it has been demonstrated that substantial crosstalk exists between S1P{sub 1} and other pro-angiogenic growth factors, such as vascular endothelial growth factor (VEGF) and basic fibroblast growth factor. We developed a novel S1P{sub 1}-selective antagonist, TASP0277308, which is structurally unrelated to S1P as well as previously described S1P{sub 1} antagonists. TASP0277308 inhibited S1P- as well as VEGF-induced cellular responses, including migration and proliferation of human umbilical vein endothelial cells. Furthermore, TASP0277308 effectively blocked a VEGF-induced tube formation in vitro and significantly suppressed tumor cell-induced angiogenesis in vivo. These findings revealed that S1P{sub 1} is a critical component of VEGF-related angiogenic responses and also provide evidence for the efficacy of TASP0277308 for anti-cancer therapies.

  17. Biliary excretion and distribution of 51Cr(III) and 51Cr(VI) in rats

    International Nuclear Information System (INIS)

    Cikrt, M.; Bencko, V.

    1979-01-01

    The biliary excretion and distribution of 51 Cr after intravenous administration of 51 Cr(III) ( 51 CrCl 3 ) or 51 Cr(VI) (Na 2 51 CrO 4 .4H 2 O) were studied in rats. The cumulative biliary excretion of 51 Cr 24 hrs after the injection was significantly higher after administration of 51 Cr(VI) than of 51 Cr(III) (3.51+-0.7% and 0.51+-0.05% of administered dose, respectively). This difference was especially due to a higher rate of biliary excretion of 51 Cr in the first hours after 51 Cr(VI) administration. The excretion of 51 Cr via feces was also higher after administration of 51 Cr(VI) (7.35+-0.45%) of administered dose, as against 4.23+-0.23% after 51 Cr(III). On the other hand, no significant difference in urinary excretion of 51 Cr was found. Statistically significant differences were also observed in the distribution of 51 Cr in the organism after administration of both valence states of the metal. (author)

  18. Pancreatic stellate cells and CX3CR1: occurrence in normal pancreas and acute and chronic pancreatitis and effect of their activation by a CX3CR1 agonist.

    Science.gov (United States)

    Uchida, Masahiko; Ito, Tetsuhide; Nakamura, Taichi; Hijioka, Masayuki; Igarashi, Hisato; Oono, Takamasa; Kato, Masaki; Nakamura, Kazuhiko; Suzuki, Koichi; Takayanagi, Ryoichi; Jensen, Robert T

    2014-07-01

    Numerous studies suggest important roles of the chemokine, fractalkine (CX3CL1), in acute/chronic pancreatitis; however, the possible mechanisms of the effects are unclear. Pancreatic stellate cells (PSCs) can play important roles in pancreatitis, secreting inflammatory cytokines/chemokines, as well as proliferation. Therefore, we investigated CX3CL1 receptor (CX3CR1) occurrence in normal pancreas and pancreatitis (acute/chronic) tissues and the effects of CX3CL1 on activated PSCs. CX3CR1 expression/localization in normal pancreas and pancreatitis (acute/chronic) tissues was evaluated with immunohistochemical analysis. CX3CR1 expression and effects of CX3CL1 on activated PSCs were examined with real-time polymerase chain reaction, BrdU (5-bromo-2-deoxyuridine) assays, and Western blotting. In normal pancreas, acinar cells expressed CX3CR1 within granule-like formations in the cytoplasm, whereas in acute/chronic pancreatitis, acinar, ductal, and activated PSCs expressed CX3CR1 on cell membranes. With activation of normal PSCs, CX3CR1 is increased. CX3CL1 activated multiple signaling cascades in PSCs. CX3CL1 did not induce inflammatory genes expression in activated PSCs, but induced proliferation. CX3CR1s are expressed in normal pancreas. Expression is increased in acute/chronic pancreatitis, and the CX3CR1s are activated. CX3CL1 induces proliferation of activated PSCs without increasing release of inflammatory mediators. These results suggest that CX3CR1 activation of PSCs could be important in their effects in pancreatitis, especially to PSC proliferation in pancreatitis where CX3CL1 levels are elevated.

  19. Data of evolutionary structure change: 1CR9H-1RUPH [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available 1CR9H-1RUPH 1CR9 1RUP H H KVKLQQSGAELVRSGASVKLSCTASGFNIKDY-YIQWVK...ine> TYR CA 299 TRP CA 347 1RUP... H 1RUPH YCAGLLWYDGGAGS...2550649642944336 1 1RUP H 1RUPH GYINY-SGFTS s

  20. Crystal structure of Cr-bearing Mg3BeAl8O16, a new polytype of magnesiotaaffeite-2N′2S

    Directory of Open Access Journals (Sweden)

    Thomas Malcherek

    2016-07-01

    Full Text Available The crystal structure of a new polytype of magnesiotaaffeite-2N′2S, ideally Mg3BeAl8O16 (trimagnesium beryllium octaaluminium hexadecaoxide, is described in space-group symmetry P-3m1. It has been identified in a fragment of a mineral sample from Burma (Myanmar. The new polytype is composed of two Mg2Al4O8 (S- and two BeMgAl4O8 (N′-modules in a stacking sequence N′SSN′′ which differs from the N′SN′S-stacking sequence of the known magnesiotaaffeite-2N′2S polytype. The crystal structure can be derived from a close-packed arrangement of O atoms and is discussed with regard to its polytypism and its Cr3+ chromophore content.

  1. Development of expression vectors for Escherichia coli based on the pCR2 replicon

    Directory of Open Access Journals (Sweden)

    Deb J K

    2007-05-01

    Full Text Available Abstract Background Recent developments in metabolic engineering and the need for expanded compatibility required for co-expression studies, underscore the importance of developing new plasmid vectors with properties such as stability and compatibility. Results We utilized the pCR2 replicon of Corynebacterium renale, which harbours multiple plasmids, for constructing a range of expression vectors. Different antibiotic-resistance markers were introduced and the vectors were found to be 100% stable over a large number of generations in the absence of selection pressure. Compatibility of this plasmid was studied with different Escherichia coli plasmid replicons viz. pMB1 and p15A. It was observed that pCR2 was able to coexist with these E.coli plasmids for 60 generations in the absence of selection pressure. Soluble intracellular production was checked by expressing GFP under the lac promoter in an expression plasmid pCR2GFP. Also high level production of human IFNγ was obtained by cloning the h-IFNγ under a T7 promoter in the expression plasmid pCR2-IFNγ and using a dual plasmid heat shock system for expression. Repeated sub-culturing in the absence of selection pressure for six days did not lead to any fall in the production levels post induction, for both GFP and h-IFNγ, demonstrating that pCR2 is a useful plasmid in terms of stability and compatibility. Conclusion We have constructed a series of expression vectors based on the pCR2 replicon and demonstrated its high stability and sustained expression capacity, in the absence of selection pressure which will make it an efficient tool for metabolic engineering and co-expression studies, as well as for scale up of expression.

  2. Helions at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2010-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent, for isotropic exposure of an adult male and an adult female to helions ( 3 He 2+ ) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Calculations were performed using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms modified to allow calculation of effective dose using tissues and tissue weighting factors from either the 1990 or 2007 recommendations of the International Commission on Radiological Protection (ICRP), and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 2%. The greatest difference, 62%, occurred at 100 MeV. Published by Oxford Univ. Press on behalf of the U.S. Government 2010. (authors)

  3. Microglia and Aging: The Role of the TREM2–DAP12 and CX3CL1-CX3CR1 Axes

    Directory of Open Access Journals (Sweden)

    Carmen Mecca

    2018-01-01

    Full Text Available Depending on the species, microglial cells represent 5–20% of glial cells in the adult brain. As the innate immune effector of the brain, microglia are involved in several functions: regulation of inflammation, synaptic connectivity, programmed cell death, wiring and circuitry formation, phagocytosis of cell debris, and synaptic pruning and sculpting of postnatal neural circuits. Moreover, microglia contribute to some neurodevelopmental disorders such as Nasu-Hakola disease (NHD, and to aged-associated neurodegenerative diseases, such as Alzheimer’s disease (AD, Parkinson’s disease (PD, and others. There is evidence that human and rodent microglia may become senescent. This event determines alterations in the microglia activation status, associated with a chronic inflammation phenotype and with the loss of neuroprotective functions that lead to a greater susceptibility to the neurodegenerative diseases of aging. In the central nervous system (CNS, Triggering Receptor Expressed on Myeloid Cells 2-DNAX activation protein 12 (TREM2-DAP12 is a signaling complex expressed exclusively in microglia. As a microglial surface receptor, TREM2 interacts with DAP12 to initiate signal transduction pathways that promote microglial cell activation, phagocytosis, and microglial cell survival. Defective TREM2-DAP12 functions play a central role in the pathogenesis of several diseases. The CX3CL1 (fractalkine-CX3CR1 signaling represents the most important communication channel between neurons and microglia. The expression of CX3CL1 in neurons and of its receptor CX3CR1 in microglia determines a specific interaction, playing fundamental roles in the regulation of the maturation and function of these cells. Here, we review the role of the TREM2-DAP12 and CX3CL1-CX3CR1 axes in aged microglia and the involvement of these pathways in physiological CNS aging and in age-associated neurodegenerative diseases.

  4. Phase stability predictions of Cr1−x, Mx)2(Al1−y, Ay)(C1−z, Xz) (M = Ti, Hf, Zr; A = Si, X = B)

    International Nuclear Information System (INIS)

    Shang, Lin; Music, Denis; Baben, Moritz to; Schneider, Jochen M

    2014-01-01

    The phase stability of (Cr 1−x , M x ) 2 (Al 1−y , A y )(C 1−z , X z ) (M = Ti, Hf, Zr; A = Si, X = B, space group P6 3 /mmc, prototype Cr 2 AlC) was studied using ab initio calculations. Based on the energy of mixing data as well as the density of states (DOS) analysis, (Cr 1−x , Zr x ) 2 AlC and (Cr 1−x , Hf x ) 2 AlC are predicted to be unstable, whereas (Cr 1−x , Ti x ) 2 AlC, Cr 2 (Al 1−y , Si y )C and Cr 2 Al(C 1−z , B z ) are predicted to be stable or metastable. The density of states analysis reveals that small differences in the position of the Fermi level alters the phase stability: (Cr 1−x , Zr x ) 2 AlC and (Cr 1−x , Hf x ) 2 AlC are predicted to be unstable or metastable as the Fermi level lies at a peak position. While the Cr dominated DOS for (Cr 1−x , Ti x ) 2 AlC plateaus at the Fermi level indicating stability. Implications of these results for the vapour phase condensation of self-healing Cr 2 AlC based materials are discussed. (paper)

  5. Carbon transfer between 2 1/4 Cr 1 Mo alloy and austenitic steels (experiments in anisothermal loops)

    International Nuclear Information System (INIS)

    Baque, P.; Besson, M.; Champeix, L.; Donati, J.R.; Oberlin, C.; Saint-Paul, P.

    1976-01-01

    Studies on carbon transfer between the ferritic steel 2 1/4 Cr 1 Mo and the austenitic steels 316L and 321H have shown that there is not any measurable carbon transfer in the operating conditions of the secondary circuit of PHENIX (475 deg C was the maximal temperature of the 2 1/4 Cr 1 Mo steel). A significant carbon transfer has been observed between the ferritic steel and the 316L steel when the 321H was replaced by the 2 1/4 Cr 1 Mo steel in the same thermohydraulic conditions (the ferritic steel was then used up to 545 deg C). This experiment has demonstrated the importance of the temperature and the initial carbon content of the ferritic steel as parameters in the decarburization process. It appears that decarburization may not be sensitive to the thermohydraulic conditions at least in the range investigated in those experiments. In the other hand the 316L steel is observed to have been carburized, the degree of carburization remaining appreciably constant and independent on the temperature between 400 deg C and 550 deg C [fr

  6. High temperature corrosion behavior of different grain size specimens of 2.25 Cr-1 Mo steel in SO2+O2 environment

    International Nuclear Information System (INIS)

    Ghosh, D.; Mitra, S.K.

    2011-01-01

    The investigation is primarily aimed at the high temperature corrosion behavior of different grain sizes of 2.25 Cr-1 Mo steel at SO 2 +O 2 (mixed oxidation and sulfidation). The various grain sizes (18 μm,26 μm, 48 μm, and 72 μm) are obtained by different annealing treatment. Isothermal corrosion studies are carried out in different grain size specimens at 973K for 8 hours. The corrosion growth rate and the reaction kinetics are studied by weight gain method. The external scales of the post corroded specimen are studied in Scanning Electron Microscope (SEM) to examine the corrosion products morphology on the scale. X-ray mapping analysis of the different elements (Fe, O, Cr and S) is carried out by Energy Dispersive Spectroscopy (EDS) attached with SEM. The X-ray Diffraction Analysis (XRD) is also carried out to identify the corrosion products in the external scale. Finally, it is concluded that that the corrosion rate of 2.25 Cr-1 Mo steel strongly depend on grain sizes of the specimens. The corrosion rate increases with the decreases of grain size. The finer grain (18 μm) show higher corrosion rate than the coarse grains (72 μm). The weight gain kinetics follows the parabolic growth rate which further indicates that the corrosion process is diffusion controlled. The scale analysis shows the thicker scale and extensive scale cracking and spallations in case of finer grain size specimen (18 μm), whereas the coarse grain specimen (72 μm) shows compact and adherent layer. The XRD analysis shows that the corrosion products consist of mixtures of iron oxides( Fe 3 O 4 and Fe 2 O 3 ) and iron sulfides (FeS). The details mechanism of the corrosion is discussed to explain the difference in corrosion rate for different grain sizes. (author)

  7. Susceptibility of 2 1/4 Cr-1Mo steel to liquid metal induced embrittlement by lithium-lead solutions

    International Nuclear Information System (INIS)

    Eberhard, B.A.; Edwards, G.R.

    1984-08-01

    An investigation has been conducted on the liquid metal induced embrittlement susceptibility of 2 1/4Cr-1Mo steel exposed to lithium and 1a/o lead-lithium at temperatures between 190 0 C and 525 0 C. This research was part of an ongoing effort to evaluate the compatibility of liquid lithium solutions with potential fusion reactor containment materials. Of particular interest was the microstructure present in a weld heat-affected zone, a microstructure known to be highly susceptible to corrosive attack by liquid lead-lithium solutions. Embrittlement susceptibility was determined by conducting tension tests on 2 1/4Cr-1Mo steel exposed to an inert environment as well as to a lead-lithium liquid and observing the change in tensile behavior. The 2 1/4Cr-1Mo steel was also given a base plate heat treatment to observe its embrittlement susceptibility to 1a/o lead-lithium. The base plate microstructure was severely embrittled at temperatures less than 500 0 C. Tempering the base plate was effective in restoring adequate ductility to the steel

  8. Microstructure and wear behaviors of laser clad NiCr/Cr3C2-WS2 high temperature self-lubricating wear-resistant composite coating

    Science.gov (United States)

    Yang, Mao-Sheng; Liu, Xiu-Bo; Fan, Ji-Wei; He, Xiang-Ming; Shi, Shi-Hong; Fu, Ge-Yan; Wang, Ming-Di; Chen, Shu-Fa

    2012-02-01

    The high temperature self-lubricating wear-resistant NiCr/Cr3C2-30%WS2 coating and wear-resistant NiCr/Cr3C2 coating were fabricated on 0Cr18Ni9 austenitic stainless steel by laser cladding. Phase constitutions and microstructures were investigated, and the tribological properties were evaluated using a ball-on-disc wear tester under dry sliding condition at room-temperature (17 °C), 300 °C and 600 °C, respectively. Results indicated that the laser clad NiCr/Cr3C2 coating consisted of Cr7C3 primary phase and γ-(Fe,Ni)/Cr7C3 eutectic colony, while the coating added with WS2 was mainly composed of Cr7C3 and (Cr,W)C carbides, with the lubricating WS2 and CrS sulfides as the minor phases. The wear tests showed that the friction coefficients of two coatings both decrease with the increasing temperature, while the both wear rates increase. The friction coefficient of laser clad NiCr/Cr3C2-30%WS2 is lower than the coating without WS2 whatever at room-temperature, 300 °C, 600 °C, but its wear rate is only lower at 300 °C. It is considered that the laser clad NiCr/Cr3C2-30%WS2 composite coating has good combination of anti-wear and friction-reducing capabilities at room-temperature up to 300 °C.

  9. Prolonging survival of corneal transplantation by selective sphingosine-1-phosphate receptor 1 agonist.

    Directory of Open Access Journals (Sweden)

    Min Gao

    Full Text Available Corneal transplantation is the most used therapy for eye disorders. Although the cornea is somewhat an immune privileged organ, immune rejection is still the major problem that reduces the success rate. Therefore, effective chemical drugs that regulate immunoreactions are needed to improve the outcome of corneal transplantations. Here, a sphingosine-1-phosphate receptor 1 (S1P1 selective agonist was systematically evaluated in mouse allogeneic corneal transplantation and compared with the commonly used immunosuppressive agents. Compared with CsA and the non-selective sphingosine 1-phosphate (S1P receptor agonist FTY720, the S1P1 selective agonist can prolong the survival corneal transplantation for more than 30 days with a low immune response. More importantly, the optimal dose of the S1P1 selective agonist was much less than non-selective S1P receptor agonist FTY720, which would reduce the dose-dependent toxicity in drug application. Then we analyzed the mechanisms of the selected S1P1 selective agonist on the immunosuppression. The results shown that the S1P1 selective agonist could regulate the distribution of the immune cells with less CD4+ T cells and enhanced Treg cells in the allograft, moreover the expression of anti-inflammatory cytokines TGF-β1 and IL-10 unregulated which can reduce the immunoreactions. These findings suggest that S1P1 selective agonist may be a more appropriate immunosuppressive compound to effectively prolong mouse allogeneic corneal grafts survival.

  10. Global radiation damage at 300 and 260 K with dose rates approaching 1 MGy s{sup −1}

    Energy Technology Data Exchange (ETDEWEB)

    Warkentin, Matthew; Badeau, Ryan; Hopkins, Jesse B. [Cornell University, Ithaca, NY 14853 (United States); Mulichak, Anne M.; Keefe, Lisa J. [Argonne National Laboratory, Argonne, IL 60439 (United States); Thorne, Robert E., E-mail: ret6@cornell.edu [Cornell University, Ithaca, NY 14853 (United States)

    2012-02-01

    Approximately half of global radiation damage to thaumatin crystals can be outrun at 260 K if data are collected in less than 1 s. Global radiation damage to 19 thaumatin crystals has been measured using dose rates from 3 to 680 kGy s{sup −1}. At room temperature damage per unit dose appears to be roughly independent of dose rate, suggesting that the timescales for important damage processes are less than ∼1 s. However, at T = 260 K approximately half of the global damage manifested at dose rates of ∼10 kGy s{sup −1} can be outrun by collecting data at 680 kGy s{sup −1}. Appreciable sample-to-sample variability in global radiation sensitivity at fixed dose rate is observed. This variability cannot be accounted for by errors in dose calculation, crystal slippage or the size of the data sets in the assay.

  11. Randomized Trial of 2 Versus 1 Dose of Measles Vaccine

    DEFF Research Database (Denmark)

    Brønd, Marie; Martins, Cesario L; Byberg, Stine

    2018-01-01

    Background: Two doses of measles vaccine (MV) might reduce the nonmeasles mortality rate more than 1 dose of MV does. The effect of 2 versus 1 dose on morbidity has not been examined. Within a randomized trial of the effect of 2 doses versus 1 dose of MV on mortality in Guinea-Bissau, we investig...

  12. X-ray fluorescence analysis of Cr6+ component in mixtures of Cr2O3 and K2CrO4

    International Nuclear Information System (INIS)

    Tochio, Tatsunori; Sakakura, Shusuke; Oohashi, Hirofumi

    2010-01-01

    X-ray fluorescence analysis using Cr K α spectra was applied to the determination of the mixing ratio of Cr 6+ to (Cr 6+ + Cr 3+ ) in several mixtures of K 2 CrO 4 and Cr 2 O 3 . Because the powder of K 2 CrO 4 contained large particles that were more than 50 μm in diameter, it was ground between a pestle and a mortar for about 8 h. The coarse particles still remaining were removed by using a sieve with 325-mesh (44 μm) in order to reduce the difference in absorption effects between emissions from Cr 6+ and those from Cr 3+ . The mixing ratio, K 2 CrO 4 /(K 2 CrO 4 + Cr 2 O 3 ), of the five mixtures investigated is 0.50, 0.40, 0.20, 0.10, and 0.05 in weight, respectively. Each spectrum obtained was analyzed by decomposing it into two reference spectra, those of the two pure materials, K 2 CrO 4 and Cr 2 O 3 , with a constant background. The results for the mixtures containing K 2 CrO 4 of more than 20 wt% are that the relative deviation from the true value is less than ∼5%. On the other hand, when the content of K 2 CrO 4 decreases to less than 10 wt%, the relative deviation gets so large as 20 - 25%. The error coming from a peak separation of spectrum involved in our results were estimated by applying our method to five sets of data for each mixture computationally generated, taking into account the uncertainty in total counts of real measurements. (author)

  13. X-ray fluorescence analysis of Cr(6+) component in mixtures of Cr(2)O(3) and K(2)CrO(4).

    Science.gov (United States)

    Tochio, Tatsunori; Sakakura, Shusuke; Oohashi, Hirofumi; Mizota, Hirohisa; Zou, Yanhui; Ito, Yoshiaki; Fukushima, Sei; Tanuma, Shigeo; Shoji, Takashi; Fujimura, Hajime; Yamashita, Michiru

    2010-01-01

    X-ray fluorescence analysis using Cr K(alpha) spectra was applied to the determination of the mixing ratio of Cr(6+) to (Cr(6+) + Cr(3+)) in several mixtures of K(2)CrO(4) and Cr(2)O(3). Because the powder of K(2)CrO(4) contained large particles that were more than 50 microm in diameter, it was ground between a pestle and a mortar for about 8 h. The coarse particles still remaining were removed by using a sieve with 325-mesh (44 microm) in order to reduce the difference in absorption effects between emissions from Cr(6+) and those from Cr(3+). The mixing ratio, K(2)CrO(4)/(K(2)CrO(4) + Cr(2)O(3)), of the five mixtures investigated is 0.50, 0.40, 0.20, 0.10, and 0.05 in weight, respectively. Each spectrum obtained was analyzed by decomposing it into two reference spectra, those of the two pure materials, K(2)CrO(4) and Cr(2)O(3), with a constant background. The results for the mixtures containing K(2)CrO(4) of more than 20 wt% are that the relative deviation from the true value is less than approximately 5%. On the other hand, when the content of K(2)CrO(4) decreases to less than 10 wt%, the relative deviation gets so large as 20 - 25%. The error coming from a peak separation of spectrum involved in our results were estimated by applying our method to five sets of data for each mixture computationally generated, taking into account the uncertainty in total counts of real measurements.

  14. Dose reduction and cost-benefit analysis at Japan`s Tokai No. 2 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Humamoto, Hisao; Suzuki, Seishiro; Taniguchi, Kazufumi [Japan Atomic Power Co., Otemachi (Japan)

    1995-03-01

    In the Tokai No. 2 power plant of the Japan Atomic Power Company, about 80% of the annual dose equivalent is received during periodic maintenance outages. A project group for dose reduction was organized at the company`s headquarters in 1986; in 1988, they proposed a five-year program to reduce by half the collective dose of 4 person-Sv per normal outage work. To achieve the target dose value, some dose-reduction measures were undertaken, namely, permanent radiation shielding, decontamination, automatic, operating machines, and ALARA organization. As the result, the collective dose from normal outage work was 1.6 person-Sv in 1992, which was less than the initial target value.

  15. Hexavalent chromium-induced apoptosis of granulosa cells involves selective sub-cellular translocation of Bcl-2 members, ERK1/2 and p53

    International Nuclear Information System (INIS)

    Banu, Sakhila K.; Stanley, Jone A.; Lee, JeHoon; Stephen, Sam D.; Arosh, Joe A.; Hoyer, Patricia B.; Burghardt, Robert C.

    2011-01-01

    Hexavalent chromium (CrVI) has been widely used in industries throughout the world. Increased usage of CrVI and atmospheric emission of CrVI from catalytic converters of automobiles, and its improper disposal causes various health hazards including female infertility. Recently we have reported that lactational exposure to CrVI induced a delay/arrest in follicular development at the secondary follicular stage. In order to investigate the underlying mechanism, primary cultures of rat granulosa cells were treated with 10 μM potassium dichromate (CrVI) for 12 and 24 h, with or without vitamin C pre-treatment for 24 h. The effects of CrVI on intrinsic apoptotic pathway(s) were investigated. Our data indicated that CrVI: (i) induced DNA fragmentation and increased apoptosis, (ii) increased cytochrome c release from the mitochondria to cytosol, (iii) downregulated anti-apoptotic Bcl-2, Bcl-XL, HSP70 and HSP90; upregulated pro-apoptotic BAX and BAD, (iv) altered translocation of Bcl-2, Bcl-XL, BAX, BAD, HSP70 and HSP90 to the mitochondria, (v) upregulated p-ERK and p-JNK, and selectively translocated p-ERK to the mitochondria and nucleus, (vi) activated caspase-3 and PARP, and (vii) increased phosphorylation of p53 at ser-6, ser-9, ser-15, ser-20, ser-37, ser-46 and ser-392, increased p53 transcriptional activation, and downregulated MDM-2. Vitamin C pre-treatment mitigated CrVI effects on apoptosis and related pathways. Our study, for the first time provides a clear insight into the effect of CrVI on multiple pathways that lead to apoptosis of granulosa cells which could be mitigated by vitamin C.

  16. Structural, magnetic, and dielectric properties of multiferroic Co1-xMgxCr2O4 nanoparticles

    Science.gov (United States)

    Kamran, M.; Ullah, A.; Rahman, S.; Tahir, A.; Nadeem, K.; Anis ur Rehman, M.; Hussain, S.

    2017-07-01

    We examined the structural, magnetic, and dielectric properties of Co1-xMgxCr2O4 nanoparticles with composition x = 0, 0.2, 0.4, 0.5, 0.6, 0.8 and 1 in detail. X-ray diffraction (XRD) revealed normal spinel structure for all the samples. Rietveld refinement fitting results of the XRD showed no impurity phases which signifies the formation of single phase Co1-xMgxCr2O4 nanoparticles. The average crystallite size showed a peak behaviour with maxima at x = 0.6. Raman and Fourier transform infrared (FTIR) spectroscopy also confirmed the formation of single phase normal spinel for all the samples and exhibited dominant vibrational changes for x ≥ 0.6. For x = 0 (CoCr2O4), zero field cooled/field cooled (ZFC/FC) magnetization curves showed paramagnetic (PM) to ferrimagnetic (FiM) transition at Tc = 97 K and a conical spiral magnetic order at Ts = 30 K. The end members CoCr2O4 (x = 0) and MgCr2O4 (x = 1) are FiM and antiferromagnetic (AFM), respectively. Tc and Ts showed decreasing trend with increasing x, followed by an additional AFM transition at TN = 15 K for x = 0.6. The system finally stabilized and changed to highly frustrated AFM structure at x = 1 due to formation of pure MgCr2O4. High field FC curves (5T) depicted nearly no effect on spiral magnetic state, which is attributed to strong exchange B-B magnetic interactions at low temperatures. Dielectric parameters showed a non-monotonous behaviour with Mg concentration and were explained with the help of Maxwell-Wagner model and Koop's theory. Dielectric properties were improved for nanoparticles with x = 0.6 and is attributed to their larger average crystallite size. In summary, Mg doping has significantly affects the structural, magnetic, and dielectric properties of CoCr2O4 nanoparticles, which can be attributed to variations in local magnetic exchange interactions and variation in average crystallite size of these chromite nanoparticles.

  17. MCR2S unstructured mesh capabilities for use in shutdown dose rate analysis

    International Nuclear Information System (INIS)

    Eade, T.; Stonell, D.; Turner, A.

    2015-01-01

    Highlights: • Advancements in shutdown dose rate calculations will be needed as fusion moves from experimental reactors to full scale demonstration reactors in order to ensure the safety of personnel. • The MCR2S shutdown dose rate tool has been modified to allow shutdown dose rates calculations using an unstructured mesh. • The unstructured mesh capability of MCR2S was used on three shutdown dose rate models, a simple sphere, the ITER computational benchmark and the DEMO computational benchmark. • The results showed a reasonable agreement between an unstructured mesh approach and the CSG approach and highlighted the need to carefully choose the unstructured mesh resolution. - Abstract: As nuclear fusion progresses towards a sustainable energy source and the power of tokamak devices increases, a greater understanding of the radiation fields will be required. As well as on-load radiation fields, off-load or shutdown radiation field are an important consideration for the safety and economic viability of a commercial fusion reactor. Previously codes such as MCR2S have been written in order to predict the shutdown dose rates within, and in regions surrounding, a fusion reactor. MCR2S utilises a constructive solid geometry (CSG) model and a superimposed structured mesh to calculate 3-D maps of the shutdown dose rate. A new approach to MCR2S calculations is proposed and implemented using a single unstructured mesh to replace both the CSG model and the superimposed structured mesh. This new MCR2S approach has been demonstrated on three models of increasing complexity. These models were: a sphere, the ITER computational shutdown dose rate benchmark and the DEMO computational shutdown dose rate benchmark. In each case the results were compared to MCR2S calculations performed using MCR2S with CSG geometry and a superimposed structured mesh. It was concluded that the results from the unstructured mesh implementation of MCR2S compared well to the CSG structured mesh

  18. Preparation of fluorinated Cr2O3 hexagonal prism and catalytic performance for the dehydrofluorination of 1,1-difluoroethane to vinyl fluoride

    Science.gov (United States)

    Han, Wenfeng; Li, Xiaojuan; Tang, Haodong; Wang, Zhikun; Xi, Miao; Li, Ying; Liu, Huazhang

    2015-09-01

    A Cr2O3 hexagonal prism structure synthesized via the reaction of aqueous CrCl3 solution with NaBH4 solution at room temperature followed by calcination of the precipitate in N2 atmosphere at 500 °C is investigated as an efficient catalyst for dehydrofluorination of 1,1-difluoroethane producing vinyl fluoride. With the assistance of scanning electron microscopy, transmission electron microscopy, and high-resolution transmission electron microscopy, experimental results revealed that the uniform hexagonal prism has a prism length of 285 ± 43 nm and width of 233 ± 33 nm. It is in the form of loose and net-like aggregation of nano-Cr2O3 with diameter less than 3-5 nm with polycrystalline structure. NH3 temperature programmed desorption and chlorodifluoromethane dismutation experiments confirm the existence of relatively abundant and strong acidic sites. As a catalyst for dehydrofluorination of 1,1-difluoroethane, compared with commercial Cr2O3, much higher activity and stability were observed due to the evolution of CrO x F y species and much higher surface area and mesoporous structure. No significant morphology changes or sintering of the catalyst are observed after 70-h reaction. Compared with the commercial Cr2O3, we suggest that the much smaller size of Cr2O3 crystalline which possesses higher surface energy, lower strength, and more abundant Lewis acidity and the formation of CrO x F y during reaction over hexagonal prism catalyst probably contributes to the activity and stability difference between these two catalysts.

  19. Experimental Charge Density Study of Trichromium Linear Metal String Complex – Cr3(dpa)4Cl2

    DEFF Research Database (Denmark)

    Wu, Lai-Chin; Cheng, Ming-Chuan; Thomsen, Maja Krüger

    An experimental and theoretical charge density study, based on Bader’s Quantum Theory: Atoms in Molecule (QTAIM), on a trichromium metal string complex, Cr3(dpa)4Cl2(C2H5OC2H5)x(CH2Cl2)1-x (1, dpa- = bis(2-pyridyl)amido)) is performed. The structure and multipole model of 1 are performed by using...... experimental X-ray diffraction data which are collected at both 100 K using conventional X-ray source (DS1) and 15 K using synchrotron source (DS2). The three chromium metal string is bridged by four dpa- ligands. These tri-chromium metal ions are bonded to each other and terminated by two Cl- ions on the both...... ends, forming a [Cl(1)Cr(1)Cr(2)Cr(3)Cl(2)] linear string. Each Cr atoms are coordinated by four N atoms of each dpa- ligand. This metal string is slightly unsymmetrical at both data sets. The bond distance, from DS1 (DS2), of Cr(1)Cr(2), 2.3480(2) (2.3669(1)) Å, is 0.03 (0.003) Å shorter than Cr...

  20. Effect of hydrostatic pressure on the structural and electronic properties of Cd{sub 0.75}Cr{sub 0.25}S

    Energy Technology Data Exchange (ETDEWEB)

    Rani, Anita [Guru Nanak College for Girls, Sri Muktsar Sahib Punjab-152026 (India); Kaur, Kulwinder; Kumar, Ranjan [Department of Physics, Panjab University Chandigarh-160014 (India); Dhiman, Shobna [Department of Applied Science, PEC, University of Technology, Chandigarh-160011 (India)

    2016-05-23

    In this paper we present the results obtained from first principle calculations of the effect of hydrostatic pressure on the structural and electronic properties of Cd{sub 1-x}Cr{sub x}S diluted magnetic semiconductor in Zinc Blende (B3) phase at x=0.25. High pressure behavior of Cd{sub 1-x}Cr{sub x}S has been investigated between 0 GPa to 100 GPa The calculations have been performed using Density functional theory as implemented in the Spanish Initiative for Electronic Simulations with Thousands of Atoms code using local density approximation as exchange-correlation (XC) potential. Calculated electronic band structures of Cd{sub 1-x}Cr{sub x}S are discussed in terms of contribution of Cr 3d{sup 5} 4s{sup 1}, Cd 4d{sup 10} 5s{sup 2}, S 3s{sup 2} 3p{sup 4} orbital’s. Study of band structures shows half-metallic ferromagnetic nature of Cd{sub 0.75}Cr{sub 0.25}S with 100% spin polarization. Under application of external pressure, the valence band and conduction band are shifted upward which leads to modification of electronic structure.

  1. Numerical simulation of Cr2N age-precipitation in high nitrogen stainless steels

    International Nuclear Information System (INIS)

    Dai, Q.X.; Yuan, Z.Z.; Luo, X.M.; Cheng, X.N.

    2004-01-01

    At the temperature raging from 700 to 950 deg. C, the Cr 2 N age-precipitation in high nitrogen austenitic stainless steels Fe24Mn18Cr3Ni0.62N was investigated in this paper. A qualitative mathematical model of Cr 2 N age-precipitation, ln t S = f (Me,1/T), was established based on the thermodynamics and kinetics and phase transformation theories. Satisfactory results were obtained by means of the test of artificial neural network. This mathematical model can be applied to the calculation design and predication of Cr 2 N age-precipitation in high nitrogen stainless steels

  2. Hierarchical Cr_2O_3@OPC composites with octahedral shape for rechargeable nonaqueous lithium-oxygen batteries

    International Nuclear Information System (INIS)

    Gan, Yongqing; Lai, Yanqing; Zhang, Zhian; Chen, Wei; Du, Ke; Li, Jie

    2016-01-01

    The development of catalyst materials is the most significant issue that hinders the practical applications of Li-O_2 batteries. Herein we show the design and synthesis of the hierarchical chromic oxide-octahedral porous carbon (Cr_2O_3@OPC) composites catalyst with octahedral shape that derived from Cr-based metal-organic frameworks (MIL-101(Cr)) precursor. When applied as cathode catalysts in rechargeable Li-O_2 batteries, the electrode with Cr_2O_3@OPC composites catalyst exhibits a low charge and discharge over-potential, high discharge capacity and excellent cycling stability. What's more, the electrode with Cr_2O_3@OPC composite shows a discharge capacity up to ∼4800 mAh g_(_c_a_t_a_l_y_s_t _+ _c_a_r_b_o_n_)"−"1 at a current density of 0.1 mA cm"−"2, and exhibits a very stable discharge voltage plateau of 2.7 V and a charge voltage plateau of ∼3.9 V. With the addition of Cr_2O_3@OPC composite, the Li-O_2 batteries can obtain good cycle performance over 50 cycles at a fixed capacity of 800 mAh g_(_c_a_t_a_l_y_s_t _+ _c_a_r_b_o_n_)"−"1. These results indicating that the Cr_2O_3@OPC composite derived from MIL-101(Cr) would be a promising catalyst for Li-O_2 batteries. - Highlights: • The Cr_2O_3@C composites were prepared by the pyrolysis of Cr-MIL-101. • The Cr_2O_3@C composites possess octahedral shape consisted of Cr_2O_3@C nanoparticle. • The Cr_2O_3@C composites have mesoporous structure with large specific area. • The Cr_2O_3@C composites have an excellent intrinsic electrocatalytic activity. • The Cr_2O_3@C electrode exhibits great cycling performance.

  3. Visible light-responded C, N and S co-doped anatase TiO{sub 2} for photocatalytic reduction of Cr(VI)

    Energy Technology Data Exchange (ETDEWEB)

    Lei, X.F., E-mail: leixuefei69@163.com [School of Resources and Materials, Northeastern University at Qinhuangdao, Qinhuangdao 066004 (China); Institute of Metallurgical Resource and Environmental Engineering, Northeastern University, Shenyang 110819 (China); Liaoning Key Laboratory of Metallurgical Resource Recycling Science, Shenyang 110819 (China); Liaoning Engineering and Technology Research Center of Boron Resource, Comprehensive, Utilization, Shenyang 110819 (China); Liaoning Provincial Universities Key Laboratory of Boron Resource Ecological, Utilization, Technology and Boron Materials, Shenyang 110819 (China); Xue, X.X.; Yang, H. [Institute of Metallurgical Resource and Environmental Engineering, Northeastern University, Shenyang 110819 (China); Liaoning Key Laboratory of Metallurgical Resource Recycling Science, Shenyang 110819 (China); Liaoning Engineering and Technology Research Center of Boron Resource, Comprehensive, Utilization, Shenyang 110819 (China); Liaoning Provincial Universities Key Laboratory of Boron Resource Ecological, Utilization, Technology and Boron Materials, Shenyang 110819 (China); Chen, C.; Li, X.; Pei, J.X.; Niu, M.C.; Yang, Y.T.; Gao, X.Y. [School of Resources and Materials, Northeastern University at Qinhuangdao, Qinhuangdao 066004 (China)

    2015-10-15

    The (C, N and S) co-doped TiO{sub 2} (TH-TiO{sub 2}) samples were synthesized by a sol-gel method calcined at 500 °C, employing butyl titanate as the titanium source and thiourea as the dopant. The structures of TH-TiO{sub 2} samples were characterized by X-ray diffraction (XRD), Transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS), UV–vis diffuse reflectance spectra (DRS), photoluminescence (PL) spectroscopy, Thermo gravimetry and differential thermal analysis (TG-DTA), Scanning electron microscopy (SEM) and nitrogen adsorption–desorption isotherms. The photocatalytic activities were checked through the photocatalytic reduction of Cr(VI) as a model compound under visible light irradiation. The results showed that the thiourea content played an important role on the microstructure and photocatalytic activity of the samples. According to XPS results, (C, N and S) atoms were successfully co-doped into the nanostructures of TH-TiO{sub 2} samples. TH-TiO{sub 2} samples with thiourea: Ti molar ratio of 1.5 exhibits higher photocatalytic activity than that of the other samples under visible light irradiation, which can be attributed to the synergic effect of the pure anatase structure, the higher light absorption characteristics in visible regions, separation efficiency of electron–hole pairs, the specific surface area and the optimum (C, N and S) content. - Graphical abstract: (C, N and S) co-doped TiO{sub 2} samples show good photocatalytic activity for Cr (VI) reduction under visible light irradiation. - Highlights: • (C, N and S) co-doping in TH-TiO{sub 2} samples can promote the formation of the pure anatase structure. • (C, N and S) atoms were successfully co-doped into the nanostructures of TH-TiO{sub 2} samples. • The band gap energy of TH-TiO{sub 2} samples reduced after (C, N and S) co-doping. • (C, N and S) co-doped TiO{sub 2} samples were effective for the photocatalytic reduction of Cr(VI) under visible light

  4. Implications of the quadratic cell survival curve and human skin radiation ''tolerance doses'' on fractionation and superfractionation dose selection

    International Nuclear Information System (INIS)

    Douglas, B.G.

    1982-01-01

    An analysis of early published multifraction orthovoltage human acute skin irradiation tolerance isoeffect doses is presented. It indicates that human acute skin radiation reactions may result from the repetition, with each dose fraction, of a cell survival curve of the form: S = e/sup -(αD + βD 2 )/). The analysis also shows no need for an independent proliferation related time factor for skin, for daily treatments of six weeks or less in duration. The value obtained for the constant β/α for orthovoltage irradiation from these data is 2.9 x 10 -3 rad -1 for the cell line determining acute skin tolerance. A radiation isoeffect relationship, based on the quadratic cell survival curve, is introduced for human skin. This relationship has some advantages over the nominal standard dose (NSD). First, its use is not restricted to tolerance level reactions. Second, a modification of the relationship, which is also introduced, may be employed in the selection of doses per treatment when irradiation dose fractions are administered at short intervals where repair of sublethal injury is incomplete

  5. Controllable one-pot synthesis of various one-dimensional Bi2S3 nanostructures and their enhanced visible-light-driven photocatalytic reduction of Cr(VI)

    International Nuclear Information System (INIS)

    Hu, Enlai; Gao, Xuehui; Etogo, Atangana; Xie, Yunlong; Zhong, Yijun; Hu, Yong

    2014-01-01

    Highlights: • 1D Bi 2 S 3 nanostructures were prepared by a facile ethanol-assisted one-pot reaction. • The size and morphology of the products can be conveniently varied. • The sulfur source plays a crucial role in determining the morphologies of products. • 1D Bi 2 S 3 nanostructures exhibit enhanced photocatalytic reduction of Cr(VI). • Bi 2 S 3 nanowires exhibit the highest photoreduction activity among three samples. - Abstract: One-dimensional (1D) Bi 2 S 3 nanostructures with various morphologies, including nanowires, nanorods, and nanotubes, have been successfully synthesized through a facile ethanol-assisted one-pot reaction. It is found that the size, morphology and structure of the products can be conveniently varied or controlled by simply adjusting the volume ratio of ethanol and water in the reaction system. Further experimental results indicate that sulfur source also plays the other crucial role in determining the product morphology. The synthetic strategy developed in this work is highly efficient in producing 1D Bi 2 S 3 nanostructures with high quality and large quantity. Photocatalysis experiments show the as-prepared 1D Bi 2 S 3 nanostructures possess significantly enhanced photocatalytic reduction of Cr(VI) when exposed to visible light irradiation. Especially, Bi 2 S 3 nanowires exhibit the highest photocatalytic activity and can be used repeatedly after washed with dilute HCl

  6. Preparation of fluorinated Cr2O3 hexagonal prism and catalytic performance for the dehydrofluorination of 1,1-difluoroethane to vinyl fluoride

    International Nuclear Information System (INIS)

    Han, Wenfeng; Li, Xiaojuan; Tang, Haodong; Wang, Zhikun; Xi, Miao; Li, Ying; Liu, Huazhang

    2015-01-01

    A Cr 2 O 3 hexagonal prism structure synthesized via the reaction of aqueous CrCl 3 solution with NaBH 4 solution at room temperature followed by calcination of the precipitate in N 2 atmosphere at 500 °C is investigated as an efficient catalyst for dehydrofluorination of 1,1-difluoroethane producing vinyl fluoride. With the assistance of scanning electron microscopy, transmission electron microscopy, and high-resolution transmission electron microscopy, experimental results revealed that the uniform hexagonal prism has a prism length of 285 ± 43 nm and width of 233 ± 33 nm. It is in the form of loose and net-like aggregation of nano-Cr 2 O 3 with diameter less than 3–5 nm with polycrystalline structure. NH 3 temperature programmed desorption and chlorodifluoromethane dismutation experiments confirm the existence of relatively abundant and strong acidic sites. As a catalyst for dehydrofluorination of 1,1-difluoroethane, compared with commercial Cr 2 O 3 , much higher activity and stability were observed due to the evolution of CrO x F y species and much higher surface area and mesoporous structure. No significant morphology changes or sintering of the catalyst are observed after 70-h reaction. Compared with the commercial Cr 2 O 3 , we suggest that the much smaller size of Cr 2 O 3 crystalline which possesses higher surface energy, lower strength, and more abundant Lewis acidity and the formation of CrO x F y during reaction over hexagonal prism catalyst probably contributes to the activity and stability difference between these two catalysts.

  7. The clinically-tested S1P receptor agonists, FTY720 and BAF312, demonstrate subtype-specific bradycardia (S1P₁ and hypertension (S1P₃ in rat.

    Directory of Open Access Journals (Sweden)

    Ryan M Fryer

    Full Text Available Sphingosine-1-phospate (S1P and S1P receptor agonists elicit mechanism-based effects on cardiovascular function in vivo. Indeed, FTY720 (non-selective S1P(X receptor agonist produces modest hypertension in patients (2-3 mmHg in 1-yr trial as well as acute bradycardia independent of changes in blood pressure. However, the precise receptor subtypes responsible is controversial, likely dependent upon the cardiovascular response in question (e.g. bradycardia, hypertension, and perhaps even species-dependent since functional differences in rodent, rabbit, and human have been suggested. Thus, we characterized the S1P receptor subtype specificity for each compound in vitro and, in vivo, the cardiovascular effects of FTY720 and the more selective S1P₁,₅ agonist, BAF312, were tested during acute i.v. infusion in anesthetized rats and after oral administration for 10 days in telemetry-instrumented conscious rats. Acute i.v. infusion of FTY720 (0.1, 0.3, 1.0 mg/kg/20 min or BAF312 (0.5, 1.5, 5.0 mg/kg/20 min elicited acute bradycardia in anesthetized rats demonstrating an S1P₁ mediated mechanism-of-action. However, while FTY720 (0.5, 1.5, 5.0 mg/kg/d elicited dose-dependent hypertension after multiple days of oral administration in rat at clinically relevant plasma concentrations (24-hr mean blood pressure = 8.4, 12.8, 16.2 mmHg above baseline vs. 3 mmHg in vehicle controls, BAF312 (0.3, 3.0, 30.0 mg/kg/d had no significant effect on blood pressure at any dose tested suggesting that hypertension produced by FTY720 is mediated S1P₃ receptors. In summary, in vitro selectivity results in combination with studies performed in anesthetized and conscious rats administered two clinically tested S1P agonists, FTY720 or BAF312, suggest that S1P₁ receptors mediate bradycardia while hypertension is mediated by S1P₃ receptor activation.

  8. The structure, magnetism, and electrical-transport properties of the Heusler alloys Co2Cr1-xFexAl (x=0.2-0.6)

    International Nuclear Information System (INIS)

    Zhang Ming; Wolf, Anne L.; Zhang, L.; Tegus, O.; Brueck, Ekkes; Wu Guangheng; Boer, Frank R. de

    2005-01-01

    We synthesize the polycrystalline Heusler compounds Co 2 Cr 1-x Fe x Al (x=0.2-0.6). The x-ray diffraction patterns show A2 structure rather than L2 1 structure. The magnetic moment and the Curie temperature increase with increasing x. The electrical resistivity characterizes the Co 2 Cr 1-x Fe x Al compounds to be not typical metals and the temperature dependence of the resistivity changes from metallic to semiconductinglike behavior with increasing Cr concentrations. We attribute the fact, which we observe for most of the compounds smaller magnetic moments than the theoretical values and the low magnetoresistance in these alloys, to the considerably high level of Co-(Cr, Fe)-type disorder

  9. The irradiation hardening of Ni-Mo-Cr and Ni-W-Cr alloy under Xe26+ ion irradiation

    Science.gov (United States)

    Chen, Huaican; Hai, Yang; Liu, Renduo; Jiang, Li; Ye, Xiang-xi; Li, Jianjian; Xue, Wandong; Wang, Wanxia; Tang, Ming; Yan, Long; Yin, Wen; Zhou, Xingtai

    2018-04-01

    The irradiation hardening of Ni-Mo-Cr and Ni-W-Cr alloy was investigated. 7 MeV Xe26+ ion irradiation was performed at room temperature and 650 °C with peak damage dose from 0.05 to 10 dpa. With the increase of damage dose, the hardness of Ni-Mo-Cr and Ni-W-Cr alloy increases, and reaches saturation at damage dose1 dpa. Moreover, the damage dose dependence of hardness in both alloys can be described by the Makin and Minter's equation, where the effective critical volume of obstacles can be used to represent irradiation hardening resistance of the alloys. Our results also show that Ni-W-Cr alloy has better irradiation hardening resistance than Ni-Mo-Cr alloy. This is ascribed to the fact that the W, instead of Mo in the alloy, can suppress the formation of defects under ion irradiation.

  10. RASCAL Version 2.1 workbook. Volume 2, Revision 2

    International Nuclear Information System (INIS)

    Athey, G.F.; Sjoreen, A.L.; McKenna, T.J.

    1994-12-01

    The Radiological Assessment System for Consequence Analysis, Version 2.1 (RASCAL 2.1) was developed for use by the NRC personnel who respond to radiological emergencies. This workbook complements the RASCAL 2.1 User's guide (NUREG/CR-5247, Vol. 1, Rev. 2). The workbook contains exercises designed to familiarize the user with the computer-based tools of RASCAL through hands-on problem solving. The workbook contains four major sections. The first is a RASCAL familiarization exercise to acquaint the user with the operation of the forms, menus, online help, and documentation. The latter three sections contain exercises in using the three tools of RASCAL Version 2.1: DECAY, FM-DOSE, and ST-DOSE. A discussion section describing how the tools could be used to solve the problems follows each set of exercises

  11. Toxic effect of Cr(VI) in presence of n-TiO2 and n-Al2O3 particles towards freshwater microalgae.

    Science.gov (United States)

    Dalai, Swayamprava; Pakrashi, Sunandan; Bhuvaneshwari, M; Iswarya, V; Chandrasekaran, N; Mukherjee, Amitava

    2014-01-01

    The reactivity and toxicity of the soluble toxicants in the presence of the engineered nanomaterials is not well explored. In this study, the probable effects of TiO2 and Al2O3 nanoparticles (n-TiO2, n-Al2O3) on the toxicity of Cr(VI) were assessed with the dominant freshwater algae, Scenedesmus obliquus, in a low range of exposure concentrations (0.05, 0.5 and 1μg/mL). In the presence of 0.05μg/mL n-TiO2, the toxicity of Cr(VI) decreased considerably, which was presumably due to the Cr(VI) adsorption on the nanoparticle surface leading to its aggregation and precipitation. The elevated n-TiO2 concentrations (0.5 and 1μg/mL) did not significantly influence Cr(VI) bio-availability, and a dose dependent toxicity of Cr(VI) was observed. On the other hand, n-Al2O3 did not have any significant effect on the Cr(VI) toxicity. The microscopic observations presented additional information on the morphological changes of the algal cells in the presence of the binary toxicants. The generation of reactive oxygen species (ROS) suggested contribution of oxidative stress on toxicity and LDH release confirmed membrane permeability of algal cells upon stress. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Characterizing and improving the toughness of thick-sectioned 2 1/4 Cr-1 Mo electroslag weldments

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, G.R.; Frost, R.H.

    1980-09-01

    Efforts to improve the toughness of electroslag weldments consisted of four endeavors: process control, changes caused in 2 1/4 Cr-1 Mo steel by electroslag welding and post-weld heat treatment, electrochemical reactions during the electroslag welding, and toughness testing.

  13. Reversal of rocuronium-induced (1.2 mg kg-1) profound neuromuscular block by accidental high dose of sugammadex (40 mg kg-1).

    NARCIS (Netherlands)

    Molina, A.L.; Boer, H.D. de; Klimek, M.; Heeringa, M.; Klein, J.

    2007-01-01

    Sugammadex is the first selective relaxant binding agent and reverses rocuronium-induced neuromuscular block. A case is reported in which a patient accidentally received a high dose of sugammadex (40 mg kg-1) to reverse a rocuronium-induced (1.2 mg kg-1) profound neuromuscular block. A fast and

  14. YSZ-based sensor using Cr-Fe-based spinel-oxide electrodes for selective detection of CO.

    Science.gov (United States)

    Anggraini, Sri Ayu; Fujio, Yuki; Ikeda, Hiroshi; Miura, Norio

    2017-08-22

    A selective carbon monoxide (CO) sensor was developed by the use of both of CuCrFeO 4 and CoCrFeO 4 as the sensing electrode (SE) for yttria-stabilized zirconia (YSZ)-based potentiometric sensor. The sensing-characteristic examinations of the YSZ-based sensors using each of spinel oxides as the single-SE sensor showed that CuCrFeO 4 -SE had the ability to detect CO, hydrocarbons and NO x gases, while CoCrFeO 4 -SE was sensitive to hydrocarbons and NO x gases. Thus, when both SEs were paired as a combined-SEs sensor, the resulting sensor could generate a selective response to CO at 450 °C under humid conditions. The sensor was also capable of detecting CO in the concentration range of 20-700 ppm. Its sensing mechanism that was examined via polarization-curve measurements was confirmed to be based on mixed-potential model. The CO response generated by the combined-SEs sensor was unaffected by the change of water vapor concentration in the range of 1.3-11.5 vol% H 2 O. Additionally, the sensing performance was stable during 13 days tested. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  16. Gas6 Promotes Inflammatory (CCR2hiCX3CR1lo) Monocyte Recruitment in Venous Thrombosis.

    Science.gov (United States)

    Laurance, Sandrine; Bertin, François-René; Ebrahimian, Talin; Kassim, Yusra; Rys, Ryan N; Lehoux, Stéphanie; Lemarié, Catherine A; Blostein, Mark D

    2017-07-01

    Coagulation and inflammation are inter-related. Gas6 (growth arrest-specific 6) promotes venous thrombosis and participates to inflammation through endothelial-innate immune cell interactions. Innate immune cells can provide the initiating stimulus for venous thrombus development. We hypothesize that Gas6 promotes monocyte recruitment during venous thrombosis. Deep venous thrombosis was induced in wild-type and Gas6-deficient (-/-) mice using 5% FeCl 3 and flow reduction in the inferior vena cava. Total monocyte depletion was achieved by injection of clodronate before deep venous thrombosis. Inflammatory monocytes were depleted using an anti-C-C chemokine receptor type 2 (CCR2) antibody. Similarly, injection of an anti-chemokine ligand 2 (CCL2) antibody induced CCL2 depletion. Flow cytometry and immunofluorescence were used to characterize the monocytes recruited to the thrombus. In vivo, absence of Gas6 was associated with a reduction of monocyte recruitment in both deep venous thrombosis models. Global monocyte depletion by clodronate leads to smaller thrombi in wild-type mice. Compared with wild type, the thrombi from Gas6 -/- mice contain less inflammatory (CCR2 hi CX 3 CR1 lo ) monocytes, consistent with a Gas6-dependent recruitment of this monocyte subset. Correspondingly, selective depletion of CCR2 hi CX 3 CR1 lo monocytes reduced the formation of venous thrombi in wild-type mice demonstrating a predominant role of the inflammatory monocytes in thrombosis. In vitro, the expression of both CCR2 and CCL2 were Gas6 dependent in monocytes and endothelial cells, respectively, impacting monocyte migration. Moreover, Gas6-dependent CCL2 expression and monocyte migration were mediated via JNK (c-Jun N-terminal kinase). This study demonstrates that Gas6 specifically promotes the recruitment of inflammatory CCR2 hi CX 3 CR1 lo monocytes through the regulation of both CCR2 and CCL2 during deep venous thrombosis. © 2017 American Heart Association, Inc.

  17. Phase relations in the systems M2MoO4-Cr2(MoO4)3-Zr(MoO4)2 (M=Li, Na, or Rb)

    International Nuclear Information System (INIS)

    Bazarov, B.G.; Chimitova, O.D.; Bazarova, Ts.T.; Arkhincheeva, S.I.; Bazarova, Zh.G.

    2008-01-01

    Phase equilibria in the systems M 2 MoO 4 -Cr 2 (MoO 4 ) 3 -Zr(MoO 4 ) 2 (M=Li, Na, or Rb) were investigated by X-ray powder diffraction analysis, DTA, and IR spectroscopy. The subsolidus structure of the phase diagrams of the systems under study was established. Two phases are formed in the Rb 2 MoO 4 -Cr 2 (MoO 4 ) 3 -Zr(MoO 4 ) 2 system with the molar ratios of the starting components equal to 5:1:1 (S 2 ) and 1:1:1 (S 1 ). Proceeding from isostructural character of Rb 5 FeHf(MoO 4 ) 6 and S 2 , the unit cell parameters are determined for S 2 [ru

  18. Structural relaxation and colour in the spinel-magnesiochromite (MgAl2O4-MgCr2O4) and gahnite-zincochromite (ZnAl2O4-ZnCr2O4) solid solution series

    Science.gov (United States)

    Hålenius, U.; Andreozzi, G. B.; Skogby, H.

    2009-04-01

    Recent studies on binary mineral solid solution series utilising synchrotron based x-ray absorption spectroscopies have indicated strong structural relaxation. For instance, it has been suggested that the real Cr-O bond distances remain nearly constant (relaxation parameter (ɛ) of 0.85, where ɛ=1 equals full relaxation) over the entire compositional range of the MgAl2O4-MgCr2O4 series (Juhin et al. 2007). In the present study we have measured room temperature optical absorption spectra of synthetic single crystals of the ZnAl2-2xCr2xO4 (0.03?x?1) and MgAl2-2xCr2xO4(0.02?x?1) series with the aim to explore the real architecture of the structure and in particular the Cr-O distance as function of composition. Our crystals were synthesized by means of flux-growth methods under atmospheric pressure and temperature profiles resulting in an estimated cation ordering temperature of ca 850 °C. Crystals close to the spinel (sensu stricto) and gahnite end-member compositions were faintly red in colour. With increasing Cr-content the crystals become more intensely red-coloured and at the higher Cr-contents there is a distinct shift towards a dark greenish colouration. These colour changes are reflected in the measured optical spectra by the position and intensity of the two spin-allowed electronic d-d transitions in octahedrally coordinated Cr3+ at ca 18000 (4A2g -4T2g (4F) transition) and 25000 cm-1(4A2g -4T1g (4F) transition). The energy of the first transition (?1-band) is ca 1200 cm-1 lower in magnesiochromite than in weakly Cr-doped spinel (x=0.02) and ca 1400 cm-1 lower in zincochromite than in gahnite with the lowest Cr-content (x=0.03). Concomitantly the energy of the second transition (?2-band) decreases with increasing Cr-content in both series by ca. 1800 cm-1. From the position of the ?1-band, a decrease in crystal field splitting, 10Dq, for six-coordinated Cr3+ with increasing Cr-content in the MgAl2-2xCr2xO4 and ZnAl2-2xCr2xO4 series of 6.5 and 7

  19. Recyclable colorimetric sensor of Cr3 + and Pb2 + ions simultaneously using a zwitterionic amino acid modified gold nanoparticles

    Science.gov (United States)

    Sang, Fuming; Li, Xin; Zhang, Zhizhou; Liu, Jia; Chen, Guofu

    2018-03-01

    In this work, a rapid, simple and sensitive colorimetric sensor for simultaneous (or respective) detection of Cr3 + and Pb2 + using tyrosine functionalized gold nanoparticles (AuNPsTyr) has been developed. Tyrosine, a natural and zwitterionic amino acid, could be as a reducing and capping agent to synthesise AuNPs and allow for the simultaneous and selective detection of Cr3 + and Pb2 +. Upon the addition of Cr3 + or Pb2 + (a combination of them), the color of AuNPsTyr solution changes from red to blue grey and the characteristic surface plasmon resonance (SPR) band is red-shifted to 580 nm due to the aggregation of AuNPs. Interestingly, the aggregated AuNPsTyr can be regnerated and recycled by removing Pb2 + and Cr3 +. Even after 3 rounds, AuNPsTyr show almost the same A580 nm / A520 nm value for the assays of Pb2 + and Cr3 +, indicating the good recyclability of the colorimetric sensor. The responding time (within 1 min) and sensitivity of the colorimetric sensor are largely improved after the addition of 0.1 M NaCl. Moreover, the AuNPsTyr aggregated by Cr3 + or Pb2 + (a combination of them) show excellent selectivity compared to other metal ions (Cr3 +, Pb2 +, Fe2 +,Cu2 +,Zn2 +,Cr6 +,Ni2 +,Co2 +,Hg2 +,Mn2 +,Mg2 +,Ca2 +,Cd2 +). More importantly, the developed sensor manifests good stability at room temperature for 3 months, which has been successfully used to determine Cr3 + and Pb2 + in the real water samples with a high sensitivity.

  20. Solid solutions on the base of CuCr2Se4 and CUsUb(1/2)Insub(1/2)Crsub(2)Sesub(4)

    International Nuclear Information System (INIS)

    Smirnov, S.G.; Rozantsev, A.V.; Kesler, Ya.A.; Gordeev, I.V.; Tret'yakov, Yu.D.

    1983-01-01

    The CuCr 2 Se 4 interaction with Cusub(1/2)Insub(1/2)Crsub(2)Sesub(4) for determining the fields of solid solutions existence and studying their crystallochemical properties is investigated. Solid solutions of the (1-x)Cusub(1/2)Insub(1/2)Crsub(2)Sesub(4)xxCuCrsub(2)Sesub(4) are prepared, two limited regions of solid solutions of spinel type at 0 <= x <= 0.2 and 0.8 <= x <= 1 are determined. X-ray radiography investigation of synthesized solid solutions is carried out. It has been found that at 0 <= x <= 0.2 solid solutions are crystallized in the ordered spinel structure F anti 43m

  1. Effect of Cr doping on structural and magnetic properties of ZnS nanoparticles

    International Nuclear Information System (INIS)

    Virpal,; Singh, Jasvir; Sharma, Sandeep; Singh, Ravi Chand

    2016-01-01

    The structural, optical and magnetic properties of pure and Cr doped ZnS nanoparticles were studied at room temperature. X-ray diffraction analysis confirmed the absence of any mixed phase and the cubic structure of ZnS in pure and Cr doped ZnS nanoparticles. Fourier transfer infrared spectra confirmed the Zn-S stretching bond at 664 cm"−"1 of ZnS in all prepared nanoparticles. The UV-Visible absorption spectra showed blue shift which became even more pronounced in Cr doped ZnS nanoparticles. However, at relatively higher Cr concentrations a slower red shift was shown by the doped nanoparticles. This phenomenon is attributed to sp-d exchange interaction that becomes prevalent at higher doping concentrations. Further, magnetic hysteresis measurements showed that Cr doped ZnS nanoparticles exhibited ferromagnetic behavior at room temperature.

  2. Fuel effect on solution combustion synthesis of Co(Cr,Al)2O4 pigments; Efecto del combustible en la síntesis de pigmentos Co(Cr,Al)2O4 por combustión de una disolución

    Energy Technology Data Exchange (ETDEWEB)

    Gilabert, J.; Palacios, M.D.; Sanz, V.; Mestre, S.

    2017-11-01

    The fuel effect on the synthesis of a ceramic pigment with a composition CoCr22ΨAl2ΨO4 (0≤Ψ≤1) by means of solution combustion synthesis process (SCS) has been studied. Three different fuels were selected to carry out the synthesis (urea, glycine and hexamethylentetramine (HMT)). Highly foamy pigments with very low density were obtained. Fd-3m spinel-type structure was obtained in all the experiments. Nevertheless, crystallinity and crystallite size of the spinels show significant differences with composition and fuel. The use of glycine along with the chromium-richest composition favours ion rearrangement to obtain the most ordered structure. Lattice parameter does not seem to be affected by fuel, although it evolves with Ψ according to Vegard's law. Colouring power in a transparent glaze shows important variations with composition. On the other hand, fuel effect presents a rather low influence since practically the same shades are obtained. However, it exerts certain effect on luminosity (L*). [Spanish] Se ha estudiado el efecto del combustible en la síntesis de pigmentos cerámicos tipo CoCr2-2ΨAl2ΨO4 (0≤Ψ≤1), obtenidos mediante síntesis por combustión de una disolución. Se seleccionaron 3 tipos de combustible diferentes: urea, glicina y hexametilentetramina. Todos los pigmentos obtenidos presentaron una textura altamente esponjosa y con muy baja densidad. Las estructuras cristalinas desarrolladas en todos los casos fueron tipo espinela Fd-3m. Sin embargo, tanto la cristalinidad como el tamaño de cristalito presentaron diferencias significativas dependiendo de la composición y del combustible utilizado. El uso de glicina, junto con las composiciones más ricas en cromo, favorece la reorganización de los iones para obtener estructuras más ordenadas y con mayor cristalinidad. El parámetro de red no parece verse afectado por el combustible, aunque sí evoluciona con Ψ de acuerdo con la Ley de Vegard. El poder colorante desarrollado

  3. Behaviour of nonlinear dynamic susceptibility above the Curie point in the cubic ferromagnetics CdCr2S4 and CdCr2Se4

    International Nuclear Information System (INIS)

    Luzyanin, I.D.; Khavronin, V.P.

    1984-01-01

    Results are presented of an experimental investigation of the behaviour of the nonlinear dynamic susceptibility in the phase transition region the cubic, weakly anisotropic ferromagnetics CdCr 2 S 4 and CdCr 2 Se 4 . It is shown that above the Curie point Tsub(C) two temperature regions, a scaling and anomalous, can be distinguished which involve critical phenomena of different nature. In the scaling region which corresponds to 4πchisub(0)) < or approximately 25, the behaviour found for the linear and nonlinear susceptibilities are in satisfactory agreement with the theoretical predictions based on similarity considerations. The anomalous region is directly adjacent to Tsub(C). In this region phenomena are observed which are not consistent with current concepts regarding the nature of second order phase transitions e.g. hysteresis with respect to magnetic field, a ''residual'' second order signal which persists a long time after switching off of the external stationary field and an anomalous behavioUr of the susceptibility at low frequencies. The resemblence of the phenomena observed in the anomalous region with those occurring in spin glasses is noted

  4. Chemokine receptors CXCR2 and CX3CR1 differentially regulate functional responses of bone-marrow endothelial progenitors during atherosclerotic plaque regression

    Science.gov (United States)

    Herlea-Pana, Oana; Yao, Longbiao; Heuser-Baker, Janet; Wang, Qiongxin; Wang, Qilong; Georgescu, Constantin; Zou, Ming-Hui; Barlic-Dicen, Jana

    2015-01-01

    Aims Atherosclerosis manifests itself as arterial plaques, which lead to heart attacks or stroke. Treatments supporting plaque regression are therefore aggressively pursued. Studies conducted in models in which hypercholesterolaemia is reversible, such as the Reversa mouse model we have employed in the current studies, will be instrumental for the development of such interventions. Using this model, we have shown that advanced atherosclerosis regression occurs when lipid lowering is used in combination with bone-marrow endothelial progenitor cell (EPC) treatment. However, it remains unclear how EPCs home to regressing plaques and how they augment atherosclerosis reversal. Here we identify molecules that support functional responses of EPCs during plaque resolution. Methods and results Chemokines CXCL1 and CX3CL1 were detected in the vascular wall of atheroregressing Reversa mice, and their cognate receptors CXCR2 and CX3CR1 were observed on adoptively transferred EPCs in circulation. We tested whether CXCL1–CXCR2 and CX3CL1–CX3CR1 axes regulate functional responses of EPCs during plaque reversal. We show that pharmacological inhibition of CXCR2 or CX3CR1, or genetic inactivation of these two chemokine receptors interfered with EPC-mediated advanced atherosclerosis regression. We also demonstrate that CXCR2 directs EPCs to regressing plaques while CX3CR1 controls a paracrine function(s) of these cells. Conclusion CXCR2 and CX3CR1 differentially regulate EPC functional responses during atheroregression. Our study improves understanding of how chemokines and chemokine receptors regulate plaque resolution, which could determine the effectiveness of interventions reducing complications of atherosclerosis. PMID:25765938

  5. Assessment of dose to patients undergoing computed radiography and film screen x-ray examinations in some Khartoum Hospitals

    International Nuclear Information System (INIS)

    Mohamed Khair, Haiffa Daffa Allah Mustafa

    2015-12-01

    Medical ionizing radiation sources give by far the largest contribution to the population dose from man made sources and most of the contribution comes from diagnostic x-rays. The optimization principle of radiation protection requires the minimization of radiation dose to patients while acquiring diagnostic quality images in radiology. In radiography, the extent of patient dose reduction is limited by the characteristics of the system used and the quality (or penetrating ability) of the x-ray beam. In this study, the entrance surface air kerma doses (ESA Ks) to patients undergoing 7 selected x-ray examinations were estimated. The study was conducted in eight hospitals in Khartoum State, comprising nine x-ray units and a total of 1200 patients were involved. Four of the hospitals involved in this study use computed radiography (CR) technology while the other four use film screen (FS) technology. The selected examinations were, abdomen (AP), chest (PA), pelvis (AP), skull (AP/PA), skull (LAT), thoracic spine (AP) and thoracic spine (LAT). The entrance surface air kerma was calculated by two methods, utilizing software CAL Dose X-3.5 and a mathematical model. Average ESAK values calculated using the two methods for hospitals using (CR) technology in mGy were 2.99 and 2.98, 0.34 and 0.31, 2.79 and 2.58, 0.76 and 0.71, 0.94 and 0.79, 3.4 and 3,2 and 5.9 and 5.03, for the above mentioned selected investigations respectively. And average ESAK values calculated using two methods for hospital using FS technology in mGy were found 4.98 and 4.19, 0.37 and 0.34, 4.15 and 3.95, 2.2 and 2. 1.3 and 1.1, 3.9 and 3.9, 9.4 and 8.3 for the above mentioned selected investigations respectively. Average ESAK values obtained by two methods for FS were higher values than the obtained by CR by 37 and 29%, 50 and 25%, 8%, 32 and 34%, 65 and 64%, 27 and 28%, 12% and 73% and 39% for the above mentioned selected investigations, respectively. This shows that CR technique allows diagnostically

  6. Chromium resistance characteristics of Cr(VI) resistance genes ChrA and ChrB in Serratia sp. S2.

    Science.gov (United States)

    He, Yuan; Dong, Lanlan; Zhou, Simin; Jia, Yan; Gu, Ruijia; Bai, Qunhua; Gao, Jieying; Li, Yingli; Xiao, Hong

    2018-08-15

    To find an efficient chromium (VI) resistance system, with a highly efficient, economical, safe, and environmentally friendly chromium-removing strain, ChrA, ChrB, and ChrAB fragments of the chromium (VI) resistance gene in Serratia sp. S2 were cloned, and their prokaryotic expression vectors were constructed and transformed into E. coli BL21. The anti-chromium (VI) capacity and characteristics of engineered bacteria, role of ChrA and ChrB genes in the anti-chromium (VI) processes, and the mechanism of chromium metabolism, were explored. The PCR technique was used to amplify ChrA, ChrB, and ChrAB genes from the Serratia sp. S2 genome. ChrA, ChrB, and ChrAB genes were connected to the prokaryotic expression vector pET-28a and transferred into E. coli BL21 for prokaryotic expression. Cr-absorption and Cr-efflux ability of the engineered strains were determined. The effects of respiratory inhibitors and oxygenated anions on Cr-efflux of ChrA and ChrB engineered strains were explored. ChrA, ChrB, and ChrAB engineered strains were constructed successfully; there was no significant difference between the control strain and the ChrB engineered strain for Cr-metabolism (P > 0.05). Cr-absorption and Cr-efflux of ChrA and ChrAB engineered strains were significantly stronger than the control strain (P < 0.05). Oxyanions (sulfate and molybdate) and inhibitors (valinomycin and CN - ) could significantly inhibit the Cr-efflux capacities of ChrA and ChrAB engineered strains (P < 0.05), while NADPH could significantly promote such capacities (P < 0.05). The Cr-transporter, encoded by ChrA gene, confer the ability to pump out intracellular Cr on ChrA and ChrAB engineered strains. The ChrB gene plays a positive regulatory role in ChrA gene regulation. The Cr-metabolism ability of the ChrAB engineered strain is stronger than the ChrA engineered strain. ChrA and ChrAB genes in the Cr-resistance system may involve a variety of mechanisms, such as sulfate ion channel and

  7. Changes induced in a ZnS:Cr-based electroluminescent waveguide structure by intrinsic near-infrared laser radiation

    International Nuclear Information System (INIS)

    Vlasenko, N. A.; Oleksenko, P. F.; Mukhlyo, M. A.; Veligura, L. I.

    2013-01-01

    The causes of changes that occur in a thin-film electroluminescent metal-insulator-semiconductor-insulator-metal waveguide structure based on ZnS:Cr (Cr concentration of ∼4 × 10 20 cm −3 ) upon lasing (λ ≈ 2.6 μm) and that induce lasing cessation are studied. It is established that lasing ceases because of light-scattering inhomogeneities formed in the structure and, hence, optical losses enhance. The origin of the inhomogeneities and the causes of their formation are clarified by studying the surface topology and the crystal structure of constituent layers of the samples before and after lasing. The studies are performed by means of atomic force microscopy and X-ray radiography. It is shown that a substantial increase in the sizes of grains on the surface of the structure is the manifestation of changes induced in the ZnS:Cr film by recrystallization. Recrystallization is initiated by local heating by absorbed laser radiation in existing Cr clusters and quickened by a strong electric field (>1 MV cm −1 ). The changes observed in the ZnS:Cr film are as follows: the textured growth of ZnS crystallites, an increase in the content of Cr clusters, and the appearance of some CrS and a rather high ZnO content. Some ways for improving the stability of lasing in the ZnS:Cr-based waveguide structures are proposed

  8. Mechanical properties of irradiated 9Cr-2WVTa steel

    International Nuclear Information System (INIS)

    Klueh, R.L.; Alexander, D.J.; Rieth, M.

    1998-01-01

    An Fe-9Cr-2W-0.25V-0.07Ta-0.1C (9Cr-2WVTa) steel has excellent strength and impact toughness before and after irradiation in the Fast Flux Test Facility and the High Flux Reactor (HFR). The ductile-brittle transition temperature (DBTT) increased only 32 C after 28 dpa at 365 C in FFTF, compared to a shift of ∼60 C for a 9Cr-2WV steel--the same as the 9Cr-2WVTa steel but without tantalum. This difference occurred despite the two steels having similar tensile but without tantalum. This difference occurred despite the two steels having similar tensile properties before and after irradiation. The 9Cr-2WVTa steel has a smaller prior-austenite grain size, but otherwise microstructures are similar before irradiation and show similar changes during irradiation. The irradiation behavior of the 9Cr-2WVTa steel differs from the 9Cr-2WV steel and other similar steels in two ways: (1) the shift in DBTT of the 9Cr-2WVTa steel irradiated in FFTF does not saturate with fluence by ∼28 dpa, whereas for the 9Cr-2WV steel and most similar steels, saturation occurs at <10 dpa, and (2) the shift in DBTT for 9Cr-2WVTa steel irradiated in FFTF and HFR increased with irradiation temperature, whereas it decreased for the 9Cr-2WV steel, as it does for most similar steels. The improved properties of the 9Cr-2WVTa steel and the differences with other steels were attributed to tantalum in solution

  9. Microstructure and temperature coefficient of resistance of thin cermet resistor films deposited from CrSi2-Cr-SiC targets by S-gun magnetron

    International Nuclear Information System (INIS)

    Felmetsger, Valery V.

    2010-01-01

    Technological solutions for producing nanoscale cermet resistor films with sheet resistances above 1000 Ω/□ and low temperature coefficients of resistance (TCR) have been investigated. 2-40 nm thick cermet films were sputter deposited from CrSi 2 -Cr-SiC targets by a dual cathode dc S-gun magnetron. In addition to studying film resistance versus temperature, the nanofilm structural features and composition were analyzed using scanning electron microscopy, atomic force microscopy, high-resolution transmission electron microscopy, energy-dispersive x-ray spectroscopy, and electron energy loss spectroscopy. This study has revealed that all cermet resistor films deposited at ambient and elevated temperatures were amorphous. The atomic ratio of Si to Cr in these films was about 2 to 1. The film TCR displayed a significant increase when the deposited film thickness was reduced below 2.5 nm. An optimized sputter process consisting of wafer degassing, cermet film deposition at elevated temperature with rf substrate bias, and a double annealing in vacuum, consisting of in situ annealing following the film sputtering and an additional annealing following the exposure of the wafers to air, has been found to be very effective for the film thermal stabilization and for fine tuning the film TCR. Cermet films with thicknesses in the range of 2.5-4 nm deposited using this technique had sheet resistances ranging from 1800 to 1200 Ω/□ and TCR values from -50 ppm/ deg. C to near zero, respectively. A possible mechanism responsible for the high efficiency of annealing the cermet films in vacuum (after preliminary exposure to air), resulting in resistance stabilization and TCR reduction, is also discussed.

  10. On the sintering behaviour of steel bonded TiC-Cr3C2 and TiC-Cr3C2-WC mixed carbides

    International Nuclear Information System (INIS)

    Stojanov, L.G.; Exner, H.E.

    1978-01-01

    Powder mixtures of TiC+Cr 3 C 2 and TiC+Cr 3 C 2 + WC were hot pressed to nearly full density. The lattice parameter of the resulting cubic mixed crystal decreases linearly with increasing additions of Cr 3 C 2 and (Cr 3 C 2 +WC 1:1). Microhardness increases with Cr 3 C 2 content up to 20 wt.%. By addition of WC, microhardness is increased further and reaches a maximum value of approx. 38 000 MN/m 2 for 20 wt.% Cr 3 C 2 and 20 wt.% WC. From these solid solutions powder compositions of Ferro-TiC type were produced by milling with 55 wt.% Fe and 0.4 wt.% C. The sintering behaviour of these powders was studied in a vacuum dilatometer. The pronounced increase of shrinkage by Cr 3 C 2 and higher amounts of Cr 3 C 2 +WC dissolved in TiC previous to binder phase melting is attributed to the increased solubility of the carbide in solid iron. Presintering at 700 0 C in hydrogen has a negative influence on sintering activity and requires much higher temperatures for complete densification during subsequent vacuum sintering. (orig.) [de

  11. Neuronal Cx3cr1 Deficiency Protects against Amyloid β-Induced Neurotoxicity

    Science.gov (United States)

    Dworzak, Jenny; Renvoisé, Benoît; Habchi, Johnny; Yates, Emma V.; Combadière, Christophe; Knowles, Tuomas P.; Dobson, Christopher M.; Blackstone, Craig; Paulsen, Ole; Murphy, Philip M.

    2015-01-01

    Cx3cr1, the receptor for the chemokine Cx3cl1 (fractalkine), has been implicated in the progression and severity of Alzheimer’s disease-like pathology in mice, but the underlying mechanisms remain unclear. A complicating factor is that Cx3cr1 has been demonstrated in both neurons and microglia. Here, we have dissected the differences between neuronal and microglial Cx3cr1, specifically by comparing direct amyloid-β-induced toxicity in cultured, mature, microglia-depleted hippocampal neurons from wild-type and Cx3cr1-/- mice. Wild-type neurons expressed both Cx3cl1 and Cx3cr1 and released Cx3cl1 in response to amyloid-β. Knockout of neuronal Cx3cr1 abated amyloid-β-induced lactate dehydrogenase release. Furthermore, amyloid-β differentially induced depression of pre- and postsynaptic components of miniature excitatory postsynaptic currents, in a peptide conformation-dependent manner. Knockout of neuronal Cx3cr1 abated effects of both amyloid-β conformational states, which were differentiable by aggregation kinetics and peptide morphology. We obtained similar results after both acute and chronic treatment of cultured neurons with the Cx3cr1 antagonist F1. Thus, neuronal Cx3cr1 may impact Alzheimer’s disease-like pathology by modulating conformational state-dependent amyloid-β-induced synaptotoxicity. PMID:26038823

  12. Compositional and structural properties of pulsed laser-deposited ZnS:Cr films

    Science.gov (United States)

    Nematollahi, Mohammadreza; Yang, Xiaodong; Seim, Eivind; Vullum, Per Erik; Holmestad, Randi; Gibson, Ursula J.; Reenaas, Turid W.

    2016-02-01

    We present the properties of Cr-doped zinc sulfide (ZnS:Cr) films deposited on Si(100) by pulsed laser deposition. The films are studied for solar cell applications, and to obtain a high absorption, a high Cr content (2.0-5.0 at.%) is used. It is determined by energy-dispersive X-ray spectroscopy that Cr is relatively uniformly distributed, and that local Cr increases correspond to Zn decreases. The results indicate that most Cr atoms substitute Zn sites. Consistently, electron energy loss and X-ray photoelectron spectroscopy showed that the films contain mainly Cr2+ ions. Structural analysis showed that the films are polycrystalline and textured. The films with ~4 % Cr are mainly grown along the hexagonal [001] direction in wurtzite phase. The average lateral grain size decreases with increasing Cr content, and at a given Cr content, increases with increasing growth temperature.

  13. Cr2O3 nanoparticle-functionalized WO3 nanorods for ethanol gas sensors

    Science.gov (United States)

    Choi, Seungbok; Bonyani, Maryam; Sun, Gun-Joo; Lee, Jae Kyung; Hyun, Soong Keun; Lee, Chongmu

    2018-02-01

    Pristine WO3 nanorods and Cr2O3-functionalized WO3 nanorods were synthesized by the thermal evaporation of WO3 powder in an oxidizing atmosphere, followed by spin-coating of the nanowires with Cr2O3 nanoparticles and thermal annealing in an oxidizing atmosphere. Scanning electron microscopy was used to examine the morphological features and X-ray diffraction was used to study the crystallinity and phase formation of the synthesized nanorods. Gas sensing tests were performed at different temperatures in the presence of test gases (ethanol, acetone, CO, benzene and toluene). The Cr2O3-functionalized WO3 nanorods sensor showed a stronger response to these gases relative to the pristine WO3 nanorod sensor. In particular, the response of the Cr2O3-functionalized WO3 nanorods sensor to 200 ppm ethanol gas was 5.58, which is approximately 4.4 times higher that of the pristine WO3 nanorods sensor. Furthermore, the Cr2O3-functionalized WO3 nanorods sensor had a shorter response and recovery time. The pristine WO3 nanorods had no selectivity toward ethanol gas, whereas the Cr2O3-functionalized WO3 nanorods sensor showed good selectivity toward ethanol. The gas sensing mechanism of the Cr2O3-functionalized WO3 nanorods sensor toward ethanol is discussed in detail.

  14. Fractographic examination of HT-9 and 9Cr-1Mo Charpy specimens irradiated in the AD-2 test

    International Nuclear Information System (INIS)

    Gelles, D.S.; Hu, W.L.

    1983-01-01

    Fracture surface topologies have been examined using scanning electron microscopy for 20 selected half sized Charpy impact specimens of HT-9 and Modified 9Cr-1Mo in order to provide improved understanding of fracture toughness degradation as a result of irradiation for Path E alloys. The specimen matrix included unirradiated specimens and specimens irradiated in EBR-II in the AD-2 experiment. Also, hardness measurements have been made on selected irradiated Charpy specimens. The results of examinations indicate that irradiation hardening due to G-phase formation at 390 0 C is responsible for the large shift in ductile-to-brittle transition temperature (DBTT) found in HT-9. Toughness degradation in HT-9 observed following higher temperature irradiations is attributed to precipitation at delta ferrite stringers. Reductions in toughness as a consequence of irradiation in Modified 9Cr-1Mo are attributed to in-reactor precipitation of (V,Nb)C and M 23 C 6 . It is shown that crack propagation rates for ductile and brittle failure modes can be measured, that they differ by over an order of magnitude and that unexpected multiple shifts in fracture mode from ductile to brittle failure can be attributed to the effect of delta ferrite stringers on crack propagation rates

  15. Does selective pleural irradiation of malignant pleural mesothelioma allow radiation dose escalation. A planning study

    International Nuclear Information System (INIS)

    Botticella, A.; Defraene, G.; Nackaerts, K.; Deroose, C.; Coolen, J.; Nafteux, P.; Vanstraelen, B.; Joosten, S.; Michiels, L.A.W.; Peeters, S.; Ruysscher, D. de

    2017-01-01

    After lung-sparing radiotherapy for malignant pleural mesothelioma (MPM), local failure at sites of previous gross disease represents the dominant form of failure. Our aim is to investigate if selective irradiation of the gross pleural disease only can allow dose escalation. In all, 12 consecutive stage I-IV MPM patients (6 left-sided and 6 right-sided) were retrospectively identified and included. A magnetic resonance imaging-based pleural gross tumor volume (GTV) was contoured. Two sets of planning target volumes (PTV) were generated for each patient: (1) a ''selective'' PTV (S-PTV), originating from a 5-mm isotropic expansion from the GTV and (2) an ''elective'' PTV (E-PTV), originating from a 5-mm isotropic expansion from the whole ipsilateral pleural space. Two sets of volumetric modulated arc therapy (VMAT) treatment plans were generated: a ''selective'' pleural irradiation plan (SPI plan) and an ''elective'' pleural irradiation plan (EPI plan, planned with a simultaneous integrated boost technique [SIB]). In the SPI plans, the average median dose to the S-PTV was 53.6 Gy (range 41-63.6 Gy). In 4 of 12 patients, it was possible to escalate the dose to the S-PTV to >58 Gy. In the EPI plans, the average median doses to the E-PTV and to the S-PTV were 48.6 Gy (range 38.5-58.7) and 49 Gy (range 38.6-59.5 Gy), respectively. No significant dose escalation was achievable. The omission of the elective irradiation of the whole ipsilateral pleural space allowed dose escalation from 49 Gy to more than 58 Gy in 4 of 12 chemonaive MPM patients. This strategy may form the basis for nonsurgical radical combined modality treatment of MPM. (orig.) [de

  16. SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Z; Hoerner, M; Lamoureux, R; Rill, L; Arreola, M [Univ Florida, Jacksonville Beach, FL (United States)

    2015-06-15

    Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations.

  17. SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

    International Nuclear Information System (INIS)

    Liu, Z; Hoerner, M; Lamoureux, R; Rill, L; Arreola, M

    2015-01-01

    Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations

  18. Hydrogen induced plastic damage in pressure vessel steel of 2.25Cr-1Mo

    International Nuclear Information System (INIS)

    Han, G.W.; Song, Y.J.

    1995-01-01

    2.25Cr-1Mo steel is generally employed as a hydrogenation reaction vessel material used at elevated temperature and in a hydrogen containing environment. During service of the reaction vessel, a large number of hydrogen atoms would enter its wall. When the reaction vessel is shutdown and the temperature reduces to about ambient temperature, the hydrogen atoms remaining in the wall would induce plastic damage in the steel. The mechanism of hydrogen induced plastic damage is different for various materials with different microstructures. Investigations have demonstrated that the hydrogen induced plastic damage in carbide annealed carbon steels is caused by hydrogen accelerating the initiating and growing of microvoids from the carbide particles. However, SEM examination on the fracture surface of hydrogen charged tensile specimen of 2.25Cr-1Mo steel show that a large number of fisheyes appear on the fracture surface. This indicates that hydrogen induced plastic damage in 2.25Cr-1Mo steel is related to the occurrence of fisheye cracks during plastic deformation. By means of micro-fracture mechanics to analyze fisheye crack occurrence from the first generation microvoid, the mechanism of hydrogen induced plastic damage in the pressure vessel steel is investigated

  19. Development of improved HP/IP rotor material 2% CrMoNiWV (23 CrMoNiWV 88)

    International Nuclear Information System (INIS)

    Wiemann, W.

    1989-01-01

    The new 2% CrMoNiWV steel has a sufficient strength level, a very good creep (rupture) behaviour and an excellent toughness behaviour for a creep resistant steel. Even after long time high temperature exposure the toughness degradation is so small that it is still better than this of best 1% CrMo(Ni)V steels. The fatigue behaviour is well comparable to this of 1% CrMo(Ni)V. The 2% CrMoNiWV steel has the capability to substitute the traditional 1% CrMo(Ni)V. (orig.) With 26 annexes

  20. Ca2Cr0.5Ga1.5O5—An extremely redox-stable brownmillerite phase

    International Nuclear Information System (INIS)

    Luo, Kun; Amano Patino, Midori; Hayward, Michael A.

    2015-01-01

    Investigation of the Ca 2 Cr x Ga 2−x O 5 compositional series reveals a maximum chromium solubility of 25%. The most chromium rich composition, Ca 2 Cr 0.5 Ga 1.5 O 5 , adopts a brownmillerite-type anion deficient perovskite structure described in space group Pnma (a=5.368 Å, b=14.547 Å, c=5.593 Å). Neutron powder diffraction data reveals rigorous B-site cation order, with all of the tetrahedral coordination sites occupied exclusively by gallium and the octahedral coordination sites occupied by gallium or chromium. Annealing studies reveals Ca 2 Cr 0.5 Ga 1.5 O 5 is stable in both oxidizing (100% O 2 ) and reducing (5% H 2 in N 2 ) conditions up to 800 °C, suggesting it could find application as a stable host lattice for fuel cell electrodes or electrolytes with suitable doping to enhance catalytic behaviour and/or anionic conductivity. - Graphical abstract: Ca 2 Cr 0.5 Ga 1.5 O 5 , adopts a brownmillerite-type anion deficient perovskite structure yet it is stable in both oxidizing (100% O 2 ) and reducing (5% H 2 in N 2 ) conditions up to 800 °C. - Highlights: • Anion deficient oxide stable to both oxidation and reduction up to 800 °C. • Cation-ordered brownmillerite structure determined by powder neutron diffraction. • Low solubility of Cr 3+ in framework due to spherical d 3 electron configuration

  1. Dose-dependent inhibition of CYP1A2, CYP2C19 and CYP2D6 by citalopram, fluoxetine, fluvoxamine and paroxetine

    DEFF Research Database (Denmark)

    Jeppesen, U; Gram, L F; Vistisen, K

    1996-01-01

    OBJECTIVE: The purpose of this pharmacokinetic study was to investigate the dose-dependent inhibition of model substrates for CYP2D6, CYP2C19 and CYP1A2 by four marketed selective serotonin reuptake inhibitors (SSRIs): citalopram, fluoxetine, fluvoxamine and paroxetine. METHODS: The study...

  2. Stabilization of MgCr2O4 spinel in slags of the
    SiO2-CaO-MgO-Cr2O3 system

    Directory of Open Access Journals (Sweden)

    Arredondo-Torres, V.

    2006-12-01

    Full Text Available El objetivo de este estudio es analizar el efecto del contenido de MgO y la basicidad de la escoria sobre la estabilidad de las especies mineralógicas del sistema de escoria SiO2-CaOMgO-
    Cr2O3. Se realizaron ensayos al equilibrio a 1600 °C bajo condiciones reductoras (pO2=10-9atm. El contenido de MgO fue de 0 a 12 % masa, el Cr2O3 de 10% y la basicidad de 1 y 1,5. También se realizó un análisis termodinámico para determinar las fases mineralógicas más estables en la escoria. Los resultados experimentales y calculados muestran que el Cr2O3 se encuentra principalmente ligado en una fase espinela MgCr2O4, incluso a bajos contenidos de MgO. Los resultados obtenidos por microscopia electrónica de barrido (MEB-EDS, muestran la evidencia de tres estructuras cristalinas: (A Octaedros, los cuales
    corresponden a la espinela MgCr2O4, (B Cristales alargados que corresponden a la formación de silicatos cálcicos y (C Matriz de silicatos cálcicos con impurezas de Mg y Cr que no cristalizaron por completo.

    El objetivo de este estudio es analizar el efecto del contenido de MgO y la basicidad de la escoria sobre la estabilidad de las especies mineralógicas del sistema de escoria SiO2-CaOMgO-Cr2O3. Se realizaron ensayos al equilibrio a 1600 °C bajo condiciones reductoras (pO2=10-9atm. El contenido de MgO fue de 0 a 12 % masa, el Cr2O3 de 10% y la basicidad de 1 y 1,5. También se realizó un análisis termodinámico para determinar las fases mineralógicas más estables en la escoria. Los resultados experimentales y calculados muestran que el Cr2O3 se encuentra principalmente ligado en una fase espinela MgCr2O4, incluso a bajos contenidos de MgO. Los resultados obtenidos por

  3. Effect of rosuvastatin dose-loading on serum sLox-1, hs-CRP, and postoperative prognosis in diabetic patients with acute coronary syndromes undergoing selected percutaneous coronary intervention (PCI).

    Science.gov (United States)

    Jiao, Yungen; Hu, Feng; Zhang, Zhengang; Gong, Kaizheng; Sun, Xiaoning; Li, Aihua; Liu, Naifeng

    2015-01-01

    To investigate the effect of rosuvastatin dose-loading on serum levels of lectin-like oxidized low-density lipoprotein receptor-1 (Lox-1) and high-sensitivity c-reactive protein (hs-CRP) and postoperative prognosis in patients with diabetes and non-ST segment elevation acute coronary syndromes (NSTEACS) undergoing selected percutaneous coronary intervention (PCI). A total of 72 patients with diabetes and NSTEACS were randomized to either the group treated with 20 mg rosuvastatin 12 hours prior to PCI with a second dose administered just before PCI (n = 33), or a control group treated with standard method according guideline (n = 39). Serum levels of sLox-1, hs-CRP, CK-MB, and cTnI were measured prior to PCI, and at 24 hours and 30 days after PCI. The 30-day incidence of major adverse cardiac events (MACE) was recorded in both groups. Compared to pre-PCI, serum levels of sLox-1 and hs-CRP of the two groups were increased at 24 hours after PCI (P PCI (P PCI, the levels of TC and LDL-C were not changed at 24 hours after PCI (P > 0.05) until 30 days after PCI (P PCI; the 30-day incidence of MACE occurred in 6.06% of patients in the loading-dose rosuvastatin-treated group and in 23.08% of patients in the control-treated group (P PCI, and also reduce the occurrence of MACE 30 days after PCI.

  4. Crystal structure, Raman scattering and magnetic properties of CuCr2-xZrxSe4 and CuCr2-xSnxSe4 selenospinels

    Science.gov (United States)

    Pinto, C.; Galdámez, A.; Barahona, P.; Moris, S.; Peña, O.

    2018-06-01

    Selenospinels, CuCr2-xMxSe4 (M = Zr and Sn), were synthesized via conventional solid-state reactions. The crystal structure of CuCr1.5Sn0.5Se4, CuCr1.7Sn0.3Se4, CuCr1.5Zr0.5Se4, and CuCr1.8Zr0.2Se4 were determined using single-crystal X-ray diffraction. All the phases crystallized in a cubic spinel-type structure. The chemical compositions of the single-crystals were examined using energy-dispersive X-ray analysis (EDS). Powder X-ray diffraction patterns of CuCr1.3Sn0.7Se4 and CuCr1.7Sn0.3Se4 were consistent with phases belonging to the Fd 3 bar m Space group. An analysis of the vibrational properties on the single-crystals was performed using Raman scattering measurements. The magnetic properties showed a spin glass behavior with increasing Sn content and ferromagnetic order for CuCr1.7Sn0.3Se4.

  5. Thermal fatigue strength estimation of 2.25Cr-1Mo steel under creep-fatigue interaction

    International Nuclear Information System (INIS)

    Kuwahara, Kazuo; Nitta, Akihito; Kitamura, Takayuki

    1980-01-01

    A 2-1/4Cr-1Mo steel is one of principal materials for high temperature equipments in nuclear and thermal power plants. The authors experimentally analyzed the high temperature fatigue strength and creep strength of a 2-1/4 Cr-1Mo steel main steam pipe which had been used in a thermal plant for operation up to 130,000 hours, and pointed out that the strain-range vs. life curves crossed each other due to the difference of temperature-strain phase in thermal fatigue. This suggests that it is difficult to estimate thermal fatigue life of steel materials having been subjected to different temperature-strain phase on the basis of isothermal low-cycle fatigue life at the upper limit temperature of thermal fatigue, and that it is urgently required to establish an appropriate method of evaluating thermal fatigue life. The authors attempted to prove that the strain range partitioning method used for the evaluation of thermal fatigue life in SUS 304 steels is applicable to this 2-1/4Cr-1Mo steel. Consequently, it was found that the thermal fatigue life could be estimated within a factor of 2.5 by the application of this method. (author)

  6. Doping effects on structural and magnetic properties of Heusler alloys Fe2Cr1-xCoxSi

    Science.gov (United States)

    Liu, Yifan; Ren, Lizhu; Zheng, Yuhong; He, Shikun; Liu, Yang; Yang, Ping; Yang, Hyunsoo; Teo, Kie Leong

    2018-05-01

    In this work, 30nm Fe2Cr1-xCoxSi (FCCS) magnetic films were deposited on Cr buffered MgO (100) substrates by sputtering. Fe2Cr0.5Co0.5Si exhibits the largest magnetization and optimal ordered L21 cubic structure at in-situ annealing temperature (Tia) of 450°C. The Co composition dependence of crystalline structures, surface morphology, defects, lattice distortions and their correlation with the magnetic properties are analyzed in detail. The Co-doped samples show in-plane M-H loops with magnetic squareness ratio of 1 and increasing anisotropy energy density with Co composition. Appropriate Co doping composition promotes L21 phase but higher Co composition converts L21 to B2 phase. Doping effect and lattice mismatch both are proved to increase the defect density. In addition, distortions of the FCCS lattice are found to be approximately linear with Co composition. The largest lattice distortion (c/a) is 0.969 for Fe2Cr0.25Co0.75Si and the smallest is 0.983 for Fe2CrSi. Our analyses suggest that these tetragonal distortions mainly induced by an elastic stress from Cr buffer account for the large in-plane anisotropy energy. This work paves the way for further tailoring the magnetic and structural properties of quaternary Heusler alloys.

  7. Fast neutron irradiation effects on CR-39 nuclear track detector for dosimetric applications

    International Nuclear Information System (INIS)

    Kader, M.H.

    2005-01-01

    The effect of neutron irradiation on the dosimetric properties of CR-39 solid-state nuclear track detector have been investigated. CR-39 samples were irradiated with neutrons of energies follow a Maxwellian distribution centered about 2 MeV. These samples were irradiated with different doses in the range 0.1-1 Sv. The background and track density were measured as a function of etching time. In addition, the dependence of sensitivity of CR-39 detector on the neutrons dose has been investigated. The results show that the Sensitivity started to increase at 0.4 Sv neutrons dose, so this sample were chosen to be a subject for further study to investigate the effect of gamma dose on its properties. The sample irradiated with 0.4 Sv were exposed to different doses of gamma rays at levels between 10 and 80 kGy. The effect of gamma doses on the bulk etching rate VB, the track diameter and the sensitivity of the CR-39 samples was investigated. The results show that the dosimetric properties of CR-39 SSNTD are greatly affected by both neutron and gamma irradiation

  8. Spin reorientation and magnetic anisotropy in Y2Co17-xCr x (x 1.17-3.0) compounds

    International Nuclear Information System (INIS)

    Fuquan, B.; Tegus, O.; Dagula, W.; Brueck, E.; Boer, F.R. de; Buschow, K.H.J.

    2005-01-01

    Spin reorientation transitions and magnetic anisotropy in Y 2 Co 17-x Cr x (x = 1.17-3.0) compounds have been investigated by means of X-ray diffraction and magnetization measurements. The powder X-ray diffraction patterns show that most samples crystallize as a single phase with the rhombohedral Th 2 Zn 17 -type structure. However, in the compound Y 2 Co 14 Cr 3 the Th 2 Zn 17 phase coexist with the hexagonal Th 2 Ni 17 -type phase. The lattice parameters a and c hardly change and the unit cell volume V increases slightly with increasing Cr content. The X-ray diffraction patterns of the aligned powder of the samples have confirmed that at room temperature the compound with x = 1.17 has planar anisotropy, but the compounds with x = 1.76, 2.34 and 3.00 have uniaxial anisotropy. Spin reorientation phenomena occur in all of the compounds. With increasing Cr content, the Curie temperature, the spin reorientation temperature, the spontaneous magnetization, and the anisotropy constant K 2 of the Y 2 Co 17-x Cr x (x = 1.17-3.0) compounds decrease strongly while the anisotropy constant K 1 increases in the range of x from 1.17 to 2.34 and then decreases in the range of x from 2.34 to 3.00

  9. Reduction and Simultaneous Removal of 99 Tc and Cr by Fe(OH) 2 (s) Mineral Transformation

    Energy Technology Data Exchange (ETDEWEB)

    Saslow, Sarah A. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Um, Wooyong [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Pearce, Carolyn I. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Engelhard, Mark H. [Environmental; Bowden, Mark E. [Environmental; Lukens, Wayne [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720, United States; Leavy, Ian I. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Riley, Brian J. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Kim, Dong-Sang [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Schweiger, Michael J. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, Washington 99354, United States; Kruger, Albert A. [United

    2017-07-17

    Technetium (Tc) remains a priority remediation concern due to persistent challenges, including rapid re-oxidation of immobilized Tc, and competing contaminants, e.g. Cr(VI), that inhibit targeted Tc reduction and incorporation into stable mineral phases. Here Fe(OH)2(s) is investigated as a comprehensive solution for overcoming these challenges, by serving as both the reductant, (Fe(II)), and immobilization agent to form Tc-incorporated magnetite (Fe3O4). Trace metal analysis suggests removal of Tc(VII) and Cr(VI) from solution occurs simultaneously; however, complete removal and reduction of Cr(VI) is achieved earlier than the removal/reduction of co-mingled Tc(VII). Bulk oxidation state analysis of the magnetite solid phase by XANES confirms that the majority of Tc is Tc(IV), which is corroborated by XPS. Furthermore, EXAFS results show successful Tc(IV) incorporation into magnetite octahedral sites without additional substitution of Cr or Tc into neighboring Fe octahedral sites. XPS analysis of Cr confirms reduction to Cr(III) and the formation of a Cr-incorporated spinel, Cr2O3, and Cr(OH)3 phases. Spinel (modeled as Fe3O4), goethite, and feroxyhyte are detected in all reacted solid phase samples analyzed by XRD, where Tc(IV) incorporation has little effect on the spinel lattice structure. In the presence of Cr(III) a spinel phase along the magnetite-chromite (Fe3O4-FeCr2O4) solid-solution line is formed.

  10. Uncertainties in contamination level and in doses after exposure to actinide aerosols

    International Nuclear Information System (INIS)

    Fritsch, P.; Berard, P.; Frank, D.; Ansoborlo, E.; Fottorino, R.; Challeton-Devatayre, C.; Miele, A.; Blanchin, N.; Raynaud, P.; Piechowski, J.

    2006-01-01

    A task group named 'Methodes Dosimetriques de Reference' (M.E.D.O.R.) has been created recently to provide didactic tools for dose estimation from bioassay data obtained after occupational exposure. This task group is focused on 1) application limits of the available models, 2) uncertainties in radionuclide biokinetics and in doses, and 3) identification of the main parameters involved in these uncertainties. First, uncertainties in biokinetics of 239 Pu (thoracic retention and excretion) and in doses have been estimated after acute inhalation of PuO 2 (A.M.A.D. 5μm, type S). This was performed either when the activity of the inhaled aerosol (case 1) or the thoracic retention on day 1 (case 2) could be measured. Variability assigned to the different parameters of the ICRP models was that previously reported. After simulation, a lognormal distribution of the results was observed so that uncertainties can be expressed as 95 % Confidence interval Ratio (C.R.=σ g 4 ). In case 1, most of the uncertainties were due to aerosol deposition and remained nearly constant for 1000 days after exposure (thoracic, faecal and urinary C.R. of 8, 6 -30 and 10, respectively). In contrast, in case 2, thoracic C.R. gradually increased from 1.5 to 5, faecal C.R. was similar to that of case 1 up to 20 days and then sharply decreased to about 3, whereas C.R. of urinary excretion remained similar to case 1 throughout the 1000 day period. Uncertainties in D.P.U.I. were much higher in case 1 (C.R.=7) than in case 2 (C.R.=2) and were both mainly due to the uncertainties in thoracic equivalent doses. Second, different bioassay data were analysed to verify if the observed results were within the C.R. previously calculated for case 2. Two cases are provided as examples which appeared out of this range. The first one corresponds to an acute exposure to PuO 2 aerosols which was followed for about 20 years. Fit analysis has shown a low value of the slow dissolution rate of the compound and an

  11. Study on structural and optical properties of α-(AlxCr1-x)2O3 (0 ≤ x ≤ 1) solid solutions

    Science.gov (United States)

    Jangir, Ravindra; Kumar, Dharmendra; Srihari, Velaga; Ganguli, Tapas

    2018-04-01

    We report on structural and optical properties for ternary α-(AlxCr1-x)2O3 (0 ≤ x ≤ 1) solid solutions synthesized by using solid sate reaction method. Single R-3c phase was obtained for the Aluminum composition of 0 ≤ x ≤ 1. Due to difference in the ionic radia of Al3+ and Cr3+, in plane lattice parameter showed deviation from the vegard's law. Optical absorption spectra for the solid solutions showed a blue shift of ˜ 0.5 eV in the optical gap. It has also been observed that Cr 3d level shifted towards the O 2p level in the valance band which indicates the enhancement of hybridization in the d and p levels, which is related to the delocalization of hole states, responsible for p-type conduction in wide band gap semiconductors. The results suggests that ternary α-(AlxCr1-x)2O3 (0 ≤ x ≤ 1) can be useful in the field of UV transparent electronics and UV photodetectors.

  12. Pengaruh jumlah Cr2O3 terhadap kelemasan kulit atasan sepatu dari kulit biawak finish natural

    Directory of Open Access Journals (Sweden)

    Mochtar Lutfie

    1996-12-01

    Full Text Available The study is aimed at detecting the amount of Cr2O3 in percent added in the tanning of lizard skins for natural finished shoe upper leather. The materials used in this study are 36 pieces of dry preservated lizard skins which are tanned to natural finished shoe upper leather, while the tanning agent used are Cr2O3 that added in veried amount as 0,5 %; 1,0 %; 1,5 % and 15 % Basyntan DLX. Using varian’s analysis, it is found that there is a significant difference in the softness of the leather caused by the amount of Cr2O3 added. The use of 1,5% Cr2O3 obviously shows the best result.

  13. Radiation induced environmental remediation of Cr(VI) heavy metal in aerated neutral solution under simulated industrial effluent

    Energy Technology Data Exchange (ETDEWEB)

    Djouider, Fathi; Aljohani, Mohammed S. [King Abdulaziz Univ., Jeddah (Saudi Arabia). Nuclear Engineering Dept.

    2017-08-01

    Cr(VI) compounds are major water contaminants in most industrial effluents, due to their carcinogenicity, while Cr(III) is an important element for human metabolism. In a previous work, we showed that Cr(VI) was radiolytically reduced to Cr(III) by the CO{sub 2}{sup -.} radical at pH 3 N{sub 2}O-saturated solution in the presence of formate. Here in the present work, this removal was investigated by steady state irradiation and pulse radiolysis in aerated solution at neutral pH, which is close to natural conditions in most wastewaters, where the reducing agent is the superoxide radical anion O{sub 2}{sup -.} The degradation of Cr(VI) increased linearly with the absorbed dose and was significantly enhanced by the added formate but not by the radiolitically produced hydrogen peroxide at this pH. The rate constant for this reduction was found to be 1.28 x 10{sup 8} M{sup -1} s{sup -1} and the absorption spectrum of Cr(V) transient species was obtained. A partial recovery of Cr(VI) is observed over a period of ca. 5 ms following a second order kinetics with a rate constant 8.0 x 10{sup 6} M{sup -1} s{sup -1}. These outcomes suggest that gamma-irradiation of Cr(VI)-contaminated wastewaters and industrial effluents in presence of formate can be simple, effective and economical means for the remediation of this major contaminant.

  14. Pancreatic stellate cells and CX3CR1: occurrence in normal pancreas, acute and chronic pancreatitis and effect of their activation by a CX3CR1 agonist

    Science.gov (United States)

    Uchida, Masahiko; Ito, Tetsuhide; Nakamura, Taichi; Hijioka, Masayuki; Igarashi, Hisato; Oono, Takamasa; Kato, Masaki; Nakamura, Kazuhiko; Suzuki, Koichi; Takayanagi, Ryoichi; Jensen, Robert T.

    2014-01-01

    Objectives Numerous studies suggest important roles of the chemokine, fractalkine (CX3CL1) in acute/chronic pancreatitis, however the possible mechanisms of the effects are unclear. Pancreatic stellate cells (PSCs) can play important roles in pancreatitis, secreting inflammatory cytokines/chemokines, as well as proliferation. Therefore, we investigated CX3CL1 receptor (CX3CR1) occurrence in normal pancreas and pancreatitis (acute/chronic) tissues, and the effects of CX3CL1 on activated-PSCs. Methods CX3CR1 expression/localization in normal pancreas and pancreatitis (acute/chronic) tissues were evaluated with immunohistochemical analysis. CX3CR1 expression and effects of CX3CL1 on activated-PSCs were examined with realtime-PCR, BrdU assays and Western Blotting. Results In normal pancreas, acinar cells expressed CX3CR1 within granule-like-formations in the cytoplasm, whereas in acute/chronic pancreatitis, acinar, ductal and activated-PSCs expressed CX3CR1 on cell membranes. With activation of normal PSCs, CX3CR1 is increased. CX3CL1 activated multiple signaling cascades in PSCs. CX3CL1, did not induce inflammatory-genes expression in activated-PSCs, but induced proliferation. Conclusions CX3CR1s are expressed in normal pancreas. Expression is increased in acute/chronic pancreatitis and the CX3CR1s are activated. CX3CL1 induces proliferation of activated-PSCs without increasing release of inflammatory-mediators. These results suggest that CX3CR1 activation of PSCs could be important in their effects in pancreatitis, especially to PSCs proliferation in pancreatitis where CX3CL1 levels are elevated. PMID:24681877

  15. High-pressure BaCrO_3 polytypes and the 5H–BaCrO_2_._8 phase

    International Nuclear Information System (INIS)

    Arévalo-López, Angel M.; Paul Attfield, J.

    2015-01-01

    Polytypism of BaCrO_3 perovskites has been investigated at 900–1100 °C and pressures up to 22 GPa. Hexagonal 5H, 4H, and 6H perovskites are observed with increasing pressure, and the cubic 3C perovskite (a=3.99503(1) Å) is observed in bulk form for the first time at 19–22 GPa. An oxygen-deficient material with limiting composition 5H–BaCrO_2_._8 is synthesised at 1200 °C under ambient pressure. This contains double tetrahedral Cr"4"+ layers and orders antiferromagnetically below 260 K with a (0 0 1/2) magnetic structure. - Graphical abstract: Hexagonal 5H, 4H, and 6H perovskites polytypes of BaCrO_3 are observed with increasing pressure and the cubic 3C perovskite is stabilised in bulk form for the first time at 19–22 GPa. Oxygen-deficient 5H–BaCrO_2_._8 synthesised at ambient pressure contains double tetrahedral Cr"4"+ layers and orders antiferromagnetically below 260 K with a (0 0 1/2) magnetic structure.

  16. Effects of ion irradiation on the residual stresses in Cr thin films

    International Nuclear Information System (INIS)

    Misra, A.; Fayeulle, S.; Kung, H.; Mitchell, T.E.; Nastasi, M.

    1998-01-01

    Cr films sputtered onto {100}thinspSi substrates at room temperature were found to be under residual tension, as revealed by wafer curvature measurements. A 150 nm thick Cr film was bombarded with 300 keV Ar ions after deposition. The intrinsic residual tensile stress increased slightly and then decreased with further increase in the ion dose. For ion doses >1x10 15 thinspions/cm 2 , the stress in the film became compressive and increased with increasing dose. Transmission electron microscopy revealed that the grain boundaries in as-deposited Cr have columnar porosity. A Cr film, ion irradiated to a dose of 5x10 15 thinspions/cm 2 , showed no grain boundary porosity. The changes in the residual stress during ion irradiation are explained by considering Ar incorporation in the film and the manner in which irradiation may change the interatomic distances and forces. copyright 1998 American Institute of Physics

  17. Enfoque del síndrome de astenia crónica

    Directory of Open Access Journals (Sweden)

    Pablo Young

    2010-06-01

    Full Text Available El término astenia deriva del griego (¢sqsneia, a: privación, sin, esthénos: vigor, fuerza, significa ausencia de fortaleza, vigor o fuerza. Es un síntoma difícil de definir, que implica un conjunto de sensaciones vagas, distintas para cada individuo. Es un motivo habitual de consulta representando hasta el 30% de la consulta ambulatoria. A su vez, la fatiga crónica representa del 1 al 10% de estos casos, y el 0.2- 0.7% del total pertenece al síndrome de fatiga crónica. Es importante saber diferenciar la astenia de la debilidad y de la disnea, ya que los pacientes habitualmente le dan el mismo significado. El factor tiempo en la astenia es útil para su caracterización. Se definió a la fatiga como prolongada cuando su duración es mayor a un mes y crónica cuando la misma supera los 6 meses. La sistematización de las entidades capaces de provocar astenia deberá guiar la búsqueda de síntomas y signos físicos, así como la indicación de estudios complementarios. La depresión es la causa más común de fatiga, representando aproximadamente la mitad de los casos. El tratamiento más efectivo de la astenia es solucionar la causa subyacente; no obstante hasta un 20% de los pacientes queda sin diagnóstico. El diagnóstico de síndrome de fatiga crónica es de exclusión y se deben usar los criterios del consenso internacional del año 1994¹. En cuanto a su tratamiento, existe evidencia a favor de utilizar ejercicio físico graduado y terapia cognitiva. La alta frecuencia del síntoma conlleva un enorme costo social y económico consumiendo recursos de manera desmesurada, por lo que es importante que los médicos estén familiarizados con este síntoma.

  18. cis-Thioindigo (TI) - a new ligand with accessible radical anion and dianion states. Strong magnetic coupling in the {[TI-(μ2-O),(μ-O)]Cp*Cr}2 dimers.

    Science.gov (United States)

    Konarev, Dmitri V; Khasanov, Salavat S; Shestakov, Alexander F; Fatalov, Alexey M; Batov, Mikhail S; Otsuka, Akihiro; Yamochi, Hideki; Kitagawa, Hiroshi; Lyubovskaya, Rimma N

    2017-10-24

    Reaction of decamethylchromocene (Cp* 2 Cr) with thioindigo (TI) yields a coordination complex {[TI-(μ 2 -O), (μ-O)]Cp*Cr} 2 ·C 6 H 14 (1) in which one Cp* ligand in Cp* 2 Cr is substituted by TI. TI adopts cis-conformation in 1 allowing the coordination of both carbonyl groups to chromium. Additionally, one oxygen atom of TI becomes a μ 2 -bridge for two chromium atoms to form {[TI-(μ 2 -O), (μ-O)]Cp*Cr} 2 dimers with a CrCr distance of 3.12 Å. According to magnetic data, diamagnetic TI 2- dianions and two Cr 3+ atoms with a high S = 3/2 spin state are present in a dimer allowing strong antiferromagnetic coupling between two Cr 3+ spins with an exchange interaction of -35.4 K and the decrease of molar magnetic susceptibility below 140 K. Paramagnetic TI˙ - radical anions with the S = 1/2 spin state have also been obtained and studied in crystalline {cryptand[2,2,2](Na + )}(TI˙ - ) (2) salt showing that both radical anion and dianion states are accessible for TI.

  19. Doses rate in contact with plastic syringes of 1, 2 and 5 mL for different beta and gamma emitting radionuclides

    International Nuclear Information System (INIS)

    Torres Berdeguez, Mirta; Ayra Pardo, Enrique; Falcon, Lazaro

    2008-01-01

    The objective of this paper is to calculate the dose rate in contact with plastic syringes of 1, 2 and 5 m L volume, unshielded and the dose rate in the same syringes after a lead or a Lucite shield of various thickness has been installed, depending on the emission of the radionuclide used. The radionuclides involved in the assessment were 32 P, 51 Cr, 90 Y, 99m Tc, 125 I, 131 I, 153 Sm, 186 Re, 188 Re, 169 Er and 177 Lu. The code used was the MCNP4C. The results are intended to be used by a Radiation Protection Officer wherever the radionuclides in question are handled to rapidly assess the dose in hands of the operators. (author)

  20. Application of 2-1/4 Cr-1 Mo as a structural material in saturated steam cycle LMFBR systems. Final report

    International Nuclear Information System (INIS)

    Licina, G.J.; Busboom, H.J.; Ring, P.J.; Roy, P.; Schmidt, C.G.; Spalaris, C.N.

    1982-02-01

    The suitability and incentives were examined for using 2-1/4Cr-1Mo steel as a structural material for the entire primary and secondary sodium systems in a 1000 MWe pool-type Liquid Metal Fast Breeder Reactor. The critical properties, advantages and disadvantages of 2-1/4Cr-1Mo, and data needed for design were described for each major component in the reactor. The relative importance of alloy properties to the successful use of ferritics in LMFBR was identified. Licensing issues, likely to surface if ferritic alloys were to be used for critical reactor components, were discussed

  1. Hot Deformation Behavior of 1Cr12Ni3Mo2VN Martensitic Stainless Steel

    Science.gov (United States)

    He, Xiaomao; Jiang, Peng; Zhou, Leyu; Chen, Chao; Deng, Xiaochun

    2017-08-01

    1Cr12Ni3Mo2VN is a new type of martensitic stainless steel for the last-stage blades of large-capacity nuclear and thermal power turbines. The deformation behavior of this steel was studied by thermal compression experiments that performed on a Gleeble-3500 thermal simulator at a temperature range of 850°C to 1200°C and a strain rate of 0.01s-1 to 20s-1. When the deformation was performed at high temperature and low strain rate, a necklace type of microstructures was observed, the plastic deformation mechanism is grain boundary slip and migration, when at low temperature and lower strain rate, the slip bands were observed, the mechanism is intracrystalline slips, and when at strain rate of 20s-1, twins were observed, the mechanism are slips and twins. The Arrhenius equation was applied to describe the constitutive equation of the flow stress. The accuracy of the equation was verified by using the experimental data and the correlation coefficient R2 = 0.9786, and the equation can provide reasonable data for the design and numerical simulation of the forging process.

  2. Antibacterial Effect of CrO and CoFe2O4 Nanoparticles upon Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Saber Imani

    2011-12-01

    Full Text Available Background & Objectives: The use of metal oxide nanoparticles can be effective to eliminate the bacterial infections, as an alternative to antibiotics. In this study, antibacterial properties of nonmaterials of CrO and CoFe2O4 are investigated against Staphylococcus aureus as a major and prevalent pathogenic bacterium to achieve sterile nano-containers. Materials & Methods: Different concentrations of CrO and CoFe2O4 nanoparticles, (0.2, 0.4, 0.6, 0.8, and 1% of each, were examined with respect to their optical density (OD culture separately. Different percentages of each nanoparticles were also examined together for the best antibacterial combination. Kinetics of Bactericidal of nanoparticles were calculated in two-hour periods and were compared with the power of other common antibiotics. Ratios of MIC/MBC were calculated by Micro dilution method, to demonstrate the bactericidal power of nanoparticles. Results: The best concentration of the nanoparticles with the highest effect of bactericidal was obtained in the presence of 1% concentration of CrO that the OD of S. aureus culture medium had reduced 4/6 times than the control group (p<0/001.Ratio of 70% CrO to 30% CoFe2O4 was the best of the Bacteriostatic properties that OD was reduced 3/3 times than the control group (p<0/05. Best kinetics of bactericidal with survival rate in the presence of 1% CrO and CoFe2O4 were obtained in 24 and 36 hours respectively. In critical concentration of 1% CrO and CoFe2O4 bactericidal power was about 67 and 56 % respectively. The MIC/MBC rate for CrO and CoFe2O4 was obtained 0/2 and 0/4 respectively. Conclusion: The results showed that CrO nanoparticle compared with CoFe2O4 has a higher bactericidal power for S. aureus infection. Therefore, by completion of these experiments and the use of metal oxide nanoparticles complex in sensitive environments such as food storage containers, etc. are suggested.

  3. The effects of minor alloy modifications and heat treatment on the microstructure and creep rupture behavior of 2.25Cr-1Mo Steel

    International Nuclear Information System (INIS)

    Todd, J.A.; Chung, D.W.; Parker, E.R.

    1983-01-01

    The effects of alloy additions on the microstructure of simulated cooled and tempered 2.25Cr-1Mo steels have been studied using transmission electron microscopy. Carbide precipitation sequences have been identified in the modification 3Cr-1Mo-1Mn-1Ni and compared to those in 2.25Cr-1Mo steels modified with Mn and Ni and also with Ti, V and B. The influence of minor compositional changes on the creep rupture behavior of 2.25Cr-1Mo steel has been studied at 500 C, 560 C, and 600 C. The most significant effect of alloy modifications on creep properties resulted from additions of Mn and Cr. Preliminary studies show that 1% Mn and 0.5Mn + 1Ni + 0.75Cr additions significantly reduce creep strength at all three temperatures for tests up to 2000 hours duration. The 3Cr-1Mo-1Mn-1Ni steel showed improvements in rupture ductility at all temperatures when compared with the base 2.25Cr-1Mo steel and the manganese-nickel modifications. Plots of the Larson-Miller parameter for both these modifications lay within the scatter band for commercial 2.25Cr-1Mo steels

  4. Age-specific inhalation radiation dose commitment factors for selected radionuclides

    International Nuclear Information System (INIS)

    Strenge, D.L.; Peloquin, R.A.; Baker, D.A.

    1982-08-01

    Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are 35 S, 36 Cl, 45 Ca, 67 Ga, 75 Se, 85 Sr, 109 Cd, 113 Sn, 125 I, 133 Ba, 170 Tm, 169 Yb, 182 Ta, 192 Ir, 198 Au, 201 Tl, 204 Tl, and 236 Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presented for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine

  5. Neoadjuvant concurrent chemoradiotherapy followed by definitive high-dose radiotherapy or surgery for operable thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Masao, Murakami; Yasumasa, Kuroda; Yosiaki, Okamoto; Koichi, Kono; Eisaku, Yoden; Fusako, Kusumi; Kiyoshi, Hajiro; Satoru, Matsusue; Hiroshi, Takeda

    1997-01-01

    Purpose: A prospective clinical trial was undertaken to investigate the feasibility of concurrent chemoradiotherapy for the esophageal carcinoma. Materials and Methods: Between June 1989 and May 1996, forty patients with operable squamous cell carcinoma of the thoracic esophagus (stage 0 to III: UICC 1987), aged 45 to 78 (mean:64), were enrolled in a study of neoadjuvant concurrent chemoradiotherapy followed by definitive high-dose radiotherapy (CRT group) or surgery (CRT-S group). Neoadjuvant chemoradiotherapy consisted of 44Gy in 40 fractions for 4 weeks (2.2Gy/2Fr./day) through 10MVX rays, with one or two courses of cisplatin (80-150mg/body, mean:90mg/m 2 , day 1, bolus injection) and 5-fluorouracil (500-1500mg/body/day, mean:600mg/m 2 , day 1-4, continuous infusion). After completion of neoadjuvant chemoradiotherapy, clinical complete response (CR) was observed in 16 patients, partial response (PR) in 22, and no change (NC) in 2. Thirty responding patients (CR:16, PR:14) entered in CRT group, and 10 non-responding patients (PR:8, NC:2) followed by surgery (CRT-S group). A cumulative median dose of 66Gy for Tis,T1 and 71Gy for T2-T4 tumor with/without high-dose-rate intraluminal brachytherapy, and one to three courses of chemotherapy were delivered in CRT group. Intraoperative radiotherapy for abdominal lymphatic system and postoperative supraclavicular irradiation were added in CRT-S group. Results: Clinical CR rate at the completion of treatment showed 90% in CRT group, and pathological CR rate 10% in CRT-S group. The overall median survival was 45 months, survival at 1, 2, 3 years being 100%, 72%, 56%, respectively. Loco-regional failure was observed in 7 patients (all in CRT group), distant failure in 6 (3 in CRT group, 3 in CRT-S group) and loco-regional with distant failure in 1 (CRT group). Four patients of loco-regional recurrence in CRT group were salvaged by surgery. Overall survival at 2-, 3-years for CRT vs. CRT-S group was 72%, 64% vs. (1(1)); 100

  6. Optical and EPR spectra of the thionitrosyl complex [Cr(OH2)5(NS)]2+

    DEFF Research Database (Denmark)

    Døssing, Anders Rørbæk; Dethlefsen, Johannes Wied

    2008-01-01

    . The optical data indicate that the NS ligand is a weaker p-acceptor than the NO ligand. The EPR parameters of [Cr(OH2)5(NS)]2+ were determined: giso, g¦ and g-: 1.96515, 1.92686(5) and 1.986860(8); Aiso(53Cr), A¦(53Cr) and A-(53Cr): 25.3´10-4, 38´10-4 and 18.5´10-4cm-1; Aiso(14N), A¦(14N) and A-(14N): 6...

  7. CX3CR1 is a modifying gene of survival and progression in amyotrophic lateral sclerosis.

    Directory of Open Access Journals (Sweden)

    Alan Lopez-Lopez

    Full Text Available The objective of this study was to investigate the association of functional variants of the human CX3CR1 gene (Fractalkine receptor with the risk of Amyotrophic Lateral Sclerosis (ALS, the survival and the progression rate of the disease symptoms in a Spanish ALS cohort. 187 ALS patients (142 sporadic [sALS] and 45 familial and 378 controls were recruited. We investigated CX3CR1 V249I (rs3732379 and T280M (rs3732378 genotypes and their haplotypes as predictors of survival, the progression rate of the symptoms (as measured by ALSFRS-R and FVC decline and the risk of suffering ALS disease. The results indicated that sALS patients with CX3CR1 249I/I or 249V/I genotypes presented a shorter survival time (42.27 ± 4.90 than patients with 249V/V genotype (67.65 ± 7.42; diff -25.49 months 95%CI [-42.79,-8.18]; p = 0.004; adj-p = 0.018. The survival time was shorter in sALS patients with spinal topography and CX3CR1 249I alleles (diff =  -29.78 months; 95%CI [-49.42,-10.14]; p = 0.003. The same effects were also observed in the spinal sALS patients with 249I-280M haplotype (diff =  -27.02 months; 95%CI [-49.57, -4.48]; p = 0.019. In the sALS group, the CX3CR1 249I variant was associated with a faster progression of the disease symptoms (OR = 2.58; 95IC% [1.32, 5.07]; p = 0.006; adj-p = 0.027. There was no evidence for association of these two CX3CR1 variants with ALS disease risk. The association evidenced herein is clinically relevant and indicates that CX3CR1 could be a disease-modifying gene in sALS. The progression rate of the disease's symptoms and the survival time is affected in patients with one or two copies of the CX3CR1 249I allele. The CX3CR1 is the most potent ALS survival genetic factor reported to date. These results reinforce the role of the immune system in ALS pathogenesis.

  8. Study report by the Committee of Actual Surbey for Radiation Doses in Digital Imaging

    International Nuclear Information System (INIS)

    Katakura, Toshihiko; Yasuhiko, Shigeru; Abe, Yoshihiro

    1995-01-01

    The aim of this questionnaire survey was to assess the reasonable radiation doses in computed radiography (CR). Questionnaires were sent to 430 facilities having CR apparatus, and 221 of these (51.3%) answered them. The conventional screen/film analog (S/F) imaging serves as control. Radiation doses of CR were smaller than or equal to those of S/F imaging. Estimated radiation doses were obtained from the skull, thoracic vertebrae, lumbar vertebrae, hip joint, leg joint, chest, abdomen, pediatric chest, pediatric hip joint, pediatric abdomen, salivary gland, renal pelvis, uterus, ovaries, and mammary glands. Exposure doses to the chest, which requires resolution, were increased. Reliability of S value was examined. S value varied greatly among CR systems. It was, however, considered to become an indicator for radiation doses in individual systems. Furthermore, image quality of CR imaging was compared with basic characteristics of S/F imaging (such as MTF, Wiener spectral value, and photographic density). MTF in CR was extremely low, as compared with HR-4/HR-S with moderate sensitivity. Wiener spectral value in CR was almost equal to that in S/F imaging at the same doses. (N.K.)

  9. 4-(2-Chloro-4-methoxy-5-methylphenyl)-N-[(1S)-2-cyclopropyl-1-(3-fluoro-4-methylphenyl)ethyl]5-methyl-N-(2-propynyl)-1,3-thiazol-2-amine hydrochloride (SSR125543A): a potent and selective corticotrophin-releasing factor(1) receptor antagonist. I. Biochemical and pharmacological characterization.

    Science.gov (United States)

    Gully, Danielle; Geslin, Michel; Serva, Laurence; Fontaine, Evelyne; Roger, Pierre; Lair, Christine; Darre, Valerie; Marcy, Claudine; Rouby, Pierre-Eric; Simiand, Jacques; Guitard, Josette; Gout, Georgette; Steinberg, Regis; Rodier, Daniel; Griebel, Guy; Soubrie, Philippe; Pascal, Marc; Pruss, Rebecca; Scatton, Bernard; Maffrand, Jean-Pierre; Le Fur, Gerard

    2002-04-01

    4-(2-Chloro-4-methoxy-5-methylphenyl)-N-[(1S)-2-cyclopropyl-1- (3-fluoro-4-methylphenyl)ethyl]5-methyl-N-(2-propynyl)-1,3-thiazol-2-amine hydrochloride (SSR125543A), a new 2-aminothiazole derivative, shows nanomolar affinity for human cloned or native corticotrophin-releasing factor (CRF)(1) receptors (pK(i) values of 8.73 and 9.08, respectively), and a 1000-fold selectivity for CRF(1) versus CRF(2 alpha) receptor and CRF binding protein. SSR125543A antagonizes CRF-induced stimulation of cAMP synthesis in human retinoblastoma Y 79 cells (IC(50) = 3.0 +/- 0.4 nM) and adrenocorticotropin hormone (ACTH) secretion in mouse pituitary tumor AtT-20 cells. SSR125543A is devoid of agonist activity in these models. Its brain penetration was demonstrated in rats by using an ex vivo [(125)I-Tyr(0)] ovine CRF binding assay. SSR125543A displaced radioligand binding to the CRF(1) receptor in the brain with an ID(50) of 6.5 mg/kg p.o. (duration of action >24 h). SSR125543A also inhibited the increase in plasma ACTH levels elicited in rats by i.v. CRF (4 microg/kg) injection (ID(50) = 1, 5, or 5 mg/kg i.v., i.p., and p.o., respectively); this effect lasted for more than 6 h when the drug was given orally at a dose of 30 mg/kg. SSR125543A (10 mg/kg p.o.) reduced by 73% the increase in plasma ACTH levels elicited by a 15-min restraint stress in rats. Moreover, SSR125543A (20 mg/kg i.p.) also antagonized the increase of hippocampal acetylcholine release induced by i.c.v. injection of 1 microg of CRF in rats. Finally, SSR125543A reduced forepaw treading induced by i.c.v. injection of 1 microg of CRF in gerbils (ID(50) = approximately 10 mg/kg p.o.). Altogether, these data indicate that SSR125543A is a potent, selective, and orally active CRF(1) receptor antagonist.

  10. Electronic, Magnetic, and Redox Properties of [MFe(3)S(4)] Clusters (M = Cd, Cu, Cr) in Pyrococcus furiosus Ferredoxin.

    Science.gov (United States)

    Staples, Christopher R.; Dhawan, Ish K.; Finnegan, Michael G.; Dwinell, Derek A.; Zhou, Zhi Hao; Huang, Heshu; Verhagen, Marc F. J. M.; Adams, Michael W. W.; Johnson, Michael K.

    1997-12-03

    The ground- and excited-state properties of heterometallic [CuFe(3)S(4)](2+,+), [CdFe(3)S(4)](2+,+), and [CrFe(3)S(4)](2+,+) cubane clusters assembled in Pyrococcus furiosus ferredoxin have been investigated by the combination of EPR and variable-temperature/variable-field magnetic circular dichroism (MCD) studies. The results indicate Cd(2+) incorporation into [Fe(3)S(4)](0,-) cluster fragments to yield S = 2 [CdFe(3)S(4)](2+) and S = (5)/(2) [CdFe(3)S(4)](+) clusters and Cu(+) incorporation into [Fe(3)S(4)](+,0) cluster fragments to yield S = (1)/(2) [CuFe(3)S(4)](2+) and S = 2 [CuFe(3)S(4)](+) clusters. This is the first report of the preparation of cubane type [CrFe(3)S(4)](2+,+) clusters, and the combination of EPR and MCD results indicates S = 0 and S = (3)/(2) ground states for the oxidized and reduced forms, respectively. Midpoint potentials for the [CdFe(3)S(4)](2+,+), [CrFe(3)S(4)](2+,+), and [CuFe(3)S(4)](2+,+) couples, E(m) = -470 +/- 15, -440 +/- 10, and +190 +/- 10 mV (vs NHE), respectively, were determined by EPR-monitored redox titrations or direct electrochemistry at a glassy carbon electrode. The trends in redox potential, ground-state spin, and electron delocalization of [MFe(3)S(4)](2+,+) clusters in P. furiosus ferredoxin are discussed as a function of heterometal (M = Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Tl).

  11. [Response of Nostoc flageliforme cell to Cu2+, Cr2+ and Pb2+ stress].

    Science.gov (United States)

    Guo, Jinying; Shi, Mingke; Zhao, Yanli; Ren, Guoyan; Yi, Junpeng; Niu, Leilei; Li, Juan

    2013-06-04

    This study aimed to investigate the effects of Cu2+, Cr2+ and Pb2+ stress on Nostoc flagelliforme cell. The response of Nostoc flagelliforme cell was analyzed under the stress. The modified BG11 culture medium containing different heavy metal ions of 0, 0.1, 1.0, 10, 100 mg/L was used to cultivate Nostoc flagelliforme cell at 25 degrees C and light intensity of 80 micromol/(m x s). Electrolyte leakage, the activities of superoxide dismutase, the content of malondialdehyde, proline, soluble protein and trehalose were analyzed. Under 1 - 100 mg/L Cu2+, Cr2+ and Pb2+ stress, electrolyte leakage and malondialdehyde contents in Nostoc flagelliforme cell were higher than those in the control group during heavy metal ions stress. Meanwhile, superoxide dismutase activity increased slightly under 10 mg/L, but was lower afterwards. The contents of proline, soluble protein and trehalose increased under 10 mg/L heavy metal ions stress, while declined under extreme heavy metal ions stress (100 mg/L). Nostoc flagelliforme cell has resistance to low heavy metal ions stress, but is damaged badly under extreme heavy metal ions stress.

  12. Void formation and helium effects in 9Cr-1MoVNb and 12Cr-1MoVW steels irradiated in HFIR and FFTF at 400/degree/C

    International Nuclear Information System (INIS)

    Maziasz, P.J.; Klueh, R.L.

    1988-01-01

    Martensitic/ferritic 9Cr-1MoVNb and 12Cr-1MoVW steels doped with up to 2 wt% Ni have up to 450 appm He after HFIR irradiation to /approximately/38 dpa, but only 5 appm He after 47 dpa in FFTF. No fine He bubbles and few or no larger voids were observable in any of these steels after FFTF irradiation at 407/degree/C. By contrast, many voids were found in the undoped steels (30-90 appm He) irradiated in HFIR at 400/degree/C, while voids plus many more fine He bubbles were found in the Ni-doped steels (400-450 appm He). Irradiation in both reactors at /approximately/400/degree/C produced significant changes in the as-tempered lath/subgrain boundary, dislocation, and precipitation structures that were sensitive to alloy composition, including doping with Ni. However, for each specific alloy the irradiation-produced changes were exactly the same comparing samples irradiated in FFTF and HFIR, particularly the Ni-doped steels. Therefore, the increased void formation appears solely due to the increased helium generation found in HFIR. While the levels of void swelling are relatively low after 37-39 dpa in HFIR (0.1-0.4%), details of the microstructural evolution suggest that void nucleation is still progressing, and swelling could increase with dose. The effect of helium on void swelling remains a valid concern for fusion application that requires higher dose experiments. 15 refs., 14 figs., 8 tabs

  13. Electronic and magnetic properties of 1T-HfS{sub 2} by doping transition-metal atoms

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xu, E-mail: zhaoxu@htu.cn [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang, Henan 453007 (China); Wang, Tianxing; Wang, Guangtao [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang, Henan 453007 (China); Dai, Xianqi [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang, Henan 453007 (China); Department of Physics, Zhengzhou Normal University, Zhengzhou, Henan 450044 (China); Xia, Congxin [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang, Henan 453007 (China); Yang, Lin [School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007 (China)

    2016-10-15

    Highlights: • Pristine 1T-HfS{sub 2} is a semiconductor with indirect gaps of 1.250 eV • Magnetism can be observed for V, Cr, Mn, Fe, Co, and Cu doping. • Strong p–d hybridization was found between TM 3d orbitals and S 3p orbitals. • V-doped 1T-HfS{sub 2} is ideal for spin injection. - Abstract: We explored the electronic and magnetic properties of 1T-HfS{sub 2} doped by transition metal (TM) atom using the first-principles calculation. We doped the transition metal atoms from the IIIB to VIB groups in nonmagnetic 1T-HfS{sub 2}. Numerical results show that the pristine 1T-HfS{sub 2} is a semiconductor with indirect gaps of 1.250 eV. Magnetism can be observed for V, Cr, Mn, Fe, Co, and Cu doping. The polarized charges mainly arise from the localized 3d electrons of the TM atom. The strong p–d hybridization was found between the 3d orbitals of TM and 3p orbitals of S. The substituted 1T-HfS{sub 2} can be a metal, semiconductor or half-metal. Analysis of the band structure and magnetic properties indicates that TM-doped HfS{sub 2} (TM = V, Fe, Cu) are promising systems to explore two-dimensional diluted magnetic semiconductors. The formation energy calculations also indicate that it is energetically favorable and relatively easier to incorporate transition metal atom into the HfS{sub 2} under S-rich experimental conditions. In contrast, V-doped HfS{sub 2} has relatively wide half-metallic gap and low formation energy. So V-doped 1T-HfS{sub 2} is ideal for spin injection, which is important for application in semiconductor spintronics.

  14. The Tribological Performance of CrMoN/MoS2 Solid Lubrication Coating on a Piston Ring

    Directory of Open Access Journals (Sweden)

    Yuelan Di

    2017-05-01

    Full Text Available In order to improve the tribological properties of an engine piston ring and enhance its service life, magnetron sputtering technology and low temperature ion sulphurizing treatment technology were used to prepare CrMoN/MoS2 solid lubricant coating on the surface of an engine piston ring. The morphologies and compositions of the surface and cross-section of the sulfuration layer were analyzed by field emission scanning electron microscopy (FESEM, and wear property under high load, high speed and high temperature conditions were tested by a SRV®4 friction and wear testing machine. The results show that the CrMoN/MoS2 composite coatings appear as a dense grain structure, and the coating is an ideal solid lubrication layer that possesses an excellent high temperature wear resistance, reducing the engine operating temperature abrasion effectively and prolonging the service life of the engine.

  15. Toxicological evaluation of the flavour ingredient N-(1-((4-amino-2,2-dioxido-1H-benzo[c][1,2,6]thiadiazin-5-yloxy-2-methylpropan-2-yl-2,6-dimethylisonicotinamide (S2218

    Directory of Open Access Journals (Sweden)

    Donald S. Karanewsky

    Full Text Available A toxicological evaluation of N-(1-((4-amino-2,2-dioxido-1H-benzo[c][1,2,6]thiadiazin-5-yloxy-2-methylpropan-2-yl-2,6-dimethylisonicotinamide (S2218; CAS 1622458-34-7, a flavour with modifying properties, was completed for the purpose of assessing its safety for use in food and beverage applications. S2218 exhibited minimal oxidative metabolism in vitro, and in rat pharmacokinetic studies, the compound was poorly orally bioavailable and rapidly eliminated. S2218 was not found to be mutagenic in an in vitro bacterial reverse mutation assay, and was found to be neither clastogenic nor aneugenic in an in vitro mammalian cell micronucleus assay. In subchronic oral toxicity studies in male and female rats, the NOAEL was 140 mg/kg bw/day (highest dose tested for S2218 sulfate salt (S8069 when administered as a food ad-mix for 13 consecutive weeks. Furthermore, S2218 sulfate salt demonstrated a lack of maternal toxicity, as well as adverse effects on fetal morphology at the highest dose tested, providing a NOAEL of 1000 mg/kg bw/day for both maternal toxicity and embryo/fetal development when administered orally during gestation to pregnant rats. Keywords: Flavours with modifying properties, S2218, FEMA GRAS, Subchronic toxicological evaluation, Genetic toxicological evaluation, Developmental toxicity evaluation

  16. Structure analysis of cation selective Cr-goethite as protective rust of weathering steel

    International Nuclear Information System (INIS)

    Konishi, Hiroyuki; Mizuki, Jun'ichiro; Yamashita, Masato; Uchida, Hitoshi

    2005-01-01

    We have performed extended X-ray absorption fine structure (EXAFS) analysis for artificial Cr-goethite to elucidate the local structure around Cr in Cr-goethite. The spectra were obtained using synchrotron radiation X-rays at the Photon Factory in Tsukuba. The first shell contributions were isolated by Fourier filtering EXAFS data, and the inverse Fourier transformed single-shell data were analyzed using a curve fitting method. The results show that Cr is coordinated with (7±1)O 2- ions. The protective characteristics of the Cr-goethite protective rust layer on weathering steel can be interpreted in terms of the O 2- coordination around Cr 3+ resulting in the creation of negative fixed charge in the Cr-goethite particles. (author)

  17. Pressure effect on magnetic and transport properties of FeCr{sub 2}S{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Y.M. [State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou 350002 (China); Tong, R. [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, Hefei 230031 (China); Yang, Z.R., E-mail: zryang@issp.ac.cn [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-10-15

    In this paper, the influence of chemical pressure caused by Se substituting and hydrostatic pressure on magnetic and transport properties of FeCr{sub 2}S{sub 4} have been investigated. In addition to a large irreversibility between zero-field-cooled (ZFC) and field-cooled (FC) magnetization under low magnetic field, FeCr{sub 2}S{sub 4} polycrystalline sample also shows a cusp-like anomaly around 70 K and a step-like transition around 9 K. With increasing Se content, ferrimagnetic transition temperature decreases, irreversibility between ZFC and FC magnetization increases. At the same time, both the step-like transition and the cusp-like anomaly in magnetization shift to a lower temperature and disappears gradually. All the above effects caused by Se substituting are in accord with the effects caused by applying hydrostatic pressure. Furthermore, we found magnetoresistance increases with increasing Se content, and attributed it to the stabilization of magnetic polarons. - Highlights: • Se doping makes the anomalies in magnetization shift toward lower temperatures. • Chemical pressure effects are in accord with hydrostatic pressure effects. • Magnetoresistance increases with increasing Se content.

  18. Structural, optical, and thermal properties of MAX-phase Cr2AlB2

    Science.gov (United States)

    Li, Xiao-Hong; Cui, Hong-Ling; Zhang, Rui-Zhou

    2018-04-01

    First-principles calculations of the structural, optical, and thermal properties of Cr2AlB2 are performed using the pseudopotential plane-wave method within the generalized gradient approximation (GGA). Calculation of the elastic constant and phonon dispersion indicates that Cr2AlB2 is mechanically and thermodynamically stable. Analysis of the band structure and density of states indicates that Cr2AlB2 is metallic. The thermal properties under increasing temperature and pressure are investigated using the quasi-harmonic Debye model. The results show that anharmonic effects on Cr2AlB2 are important at low temperature and high pressure. The calculated equilibrium primitive cell volume is 95.91 Å3 at T = 300 K, P = 0 GPa. The ability of Cr2AlB2 to resist volume changes becomes weaker with increasing temperature and stronger with increasing pressure. Analysis of optical properties of Cr2AlB2 shows that the static dielectric function of Cr2AlB2 is 53.1, and the refractive index n 0 is 7.3. If the incident light has a frequency exceeding 16.09 eV, which is the plasma frequency of Cr2AlB2, Cr2AlB2 changes from metallic to dielectric material.

  19. Evaluation of the CR{sub 3}C{sub 2}(NICR) coating deposited on S4400 with the HVOF process for PEM fuel flow plates; Evaluacion del recubrimiento CR{sub 3}C{sub 2}(NICR) depositado sobre S4400 por el proceso HVOF para placas de flujo de celdas de combustible PEM

    Energy Technology Data Exchange (ETDEWEB)

    Rendon Belmonte, M.; Perez Quiroz, J.T. [Instituto Mexicano del Transporte, Queretaro, Queretaro (Mexico)]. E-mail: marielarb17@hotmail.com; Porcayo Calderon, J. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Orozco, G. [Centro de Investigacion y Desarrollo Tecnologico en Electroquimica S. C., Queretaro, Queretaro (Mexico)

    2009-09-15

    This research studied the behavior of Cr{sub 3}C{sub 2}(NiCr) coating deposited on S4400 with the HVOF (High Velocity Oxygen-Fuel) thermal projection process. Coating was applied after the surface of the plate was prepared with ceramic granulated metal burst according to norm NACE No. 1/ SSPC-SP 5 and cleaned with acetone. The electrolyte used was an H{sub 2}SO{sub 4} 0,5 M + 2 ppm F{sup -} solution at ambient temperature. Mercury sulfate (Hg{sub 2}SO{sub 4}) electrode was used as the reference electrode and the counter electrode used was a graphite bar. To study the electrochemical behavior, polarization curves were generated with a sweep speed of 0.15 mV/s, according to norms ASTM G5 and ASTM G59. Before testing, the Ecorr was measured with a high impedance multimeter (10{sup 6}). The morphological aspect of the coating evaluated was analyzed with SEM (sweep electron microscopy). Based on the obtained icorr values of 1.7*10{sup -4} mA/cm{sup 2} for a period of 576 hours, we can state that this coating meets the criteria for resistance to corrosion required by the DOE (U.S. Department of Energy) for consideration of its use in PEM fuel cell flow plates. [Spanish] En esta investigacion se estudio el comportamiento del recubrimiento Cr{sub 3}C{sub 2}(NiCr), depositado sobre S4400 mediante el proceso de proyeccion termica HVOF (High Velocity Oxygen-Fuel). Previo a la aplicacion del recubrimiento, la placa fue preparada superficialmente mediante rafaga de granalla ceramica de acuerdo con la norma NACE No. 1/ SSPC-SP 5, limpiada con acetona y en esta condicion se procedio a la aplicacion del recubrimiento. El electrolito empleado fue una solucion de H{sub 2}SO{sub 4} 0,5 M + 2 ppm F{sup -} a temperatura ambiente, como electrodo de referencia se empleo un electrodo de sulfato mercuroso (Hg{sub 2}SO{sub 4}) y como contraelectrodo una barra de grafito. Para estudiar el comportamiento electroquimico se realizaron curvas de polarizacion con una velocidad de barrido de 0

  20. A first-principles study on the structural, mechanical, electronic and optical properties of the Cr2(AlxGe1−x)C alloys

    International Nuclear Information System (INIS)

    Zhao-Yong, Jiao; Shu-Hong, Ma; Xiao-Fen, Huang

    2014-01-01

    Highlights: • The structural, mechanical and optical properties of Cr 2 (Al x Ge 1−x )C are studied. • The sound velocity and the Debye temperatures for the Cr 2 (Al x Ge 1−x )C are predicted. • Results classify the Cr 2 (Al x Ge 1−x )C (x ⩽ 0.5) as ductile while (x = 0.75, 1) as brittle. • Cr 2 (Al x Ge 1−x )C are predicted to be promising good coating materials. -- Abstract: According to the new experimentally discovered Cr 2 (Al x Ge 1−x )C (x = 0, 0.25, 0.5, 0.75, 1) alloys, we have studied the structural, mechanical, electronic and optical properties based on the first-principles calculation. Obtained structural parameters and distortion parameters are in good agreement with experimental results. It is shown that all the considered compounds are elastically stable and present results classify the Cr 2 (Al x Ge 1−x )C (x ⩽ 0.5) alloys as ductile while the Cr 2 (Al 0.75 Ge 0.25 )C and Cr 2 AlC as brittle. Electronic and optical properties demonstrate that all the considered M 2 AX compounds have a metallic character, and they are predictive of promising good coating materials

  1. Effect of Cr-sources on performance of Li1.05Cr0.04Mn1.96O4 cathode materials prepared by slurry spray drying method

    International Nuclear Information System (INIS)

    Peng, Z.D.; Jiang, Q.L.; Du, K.; Wang, W.G.; Hu, G.R.; Liu, Y.X.

    2010-01-01

    The effect of Cr-sources on the performance of Li 1.05 Cr 0.04 Mn 1.96 O 4 prepared by slurry spray drying method was studied by adopting three different chromic compounds, Cr 2 O 3 , Cr 2 (SO 4 ) 3 and Cr(CH 3 COO) 3 , respectively. The prepared powder materials were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), laser particle size analyzer and Brunauer-Emmett-Teller (BET) specific surface area test. Electrochemical performances of these cathode materials were investigated by electrochemical impedance spectroscopy (EIS) and charge-discharge tests with Li/LiCr x Mn 2-x O 4 coin-type batteries. The results indicate that porous spherical particles with average particle size of about 24 μm can be obtained by slurry spray drying process. Using Cr(CH 3 COO) 3 as Cr-source resulted in the better mixing properties, which can make the as-prepared CA-Li 1.05 Cr 0.04 Mn 1.96 O 4 having smaller lattice parameter, smaller grain size and better structure stability, and consequently the obtained sample showed low charge transfer impedance and electrochemical polarization, and exhibited good electrochemical performance at elevated temperature.

  2. Treatment of selected primary gynecologic and pelvic malignancies with 241Americium

    International Nuclear Information System (INIS)

    Chung, Joyce Y.; Peschel, Richard E.; Kacinski, Barry; Nath, Ravinder; Pourang, Rauman; Roberts, Kenneth; Fischer, Diana; Chambers, Joseph; Schwartz, Peter E.; Wilson, Lynn

    1995-01-01

    Purpose: To evaluate the efficacy of encapsulated 241 Am in the treatment of primary gynecological malignancies and in previously irradiated patients with recurrent disease in the pelvis. Materials and Methods: Encapsulated 241 Am primarily emits 60keV photons which are effectively shielded by thin layers of high atomic number materials. Dose distributions in water are similar to those produced by Cs-137 photons but with a half-value layer that is considerably less. Cases of 28 patients (12-primary, 16-recurrent) who have been treated with 241 Am at the Yale University School of Medicine since 1986 were retrospectively reviewed. Data concerning dosimetry, disease site, prior treatment, recurrence, disease-free survival, overall survival, and complications were evaluated. Results: Median follow up for the 12 patients with primary gynecological tumors was 19 months (7mo-51mo). There were 6 vulvar, 3 vaginal, 2 cervical and 1 endometrial carcinomas. Median surface dose of 241 Am was 42.2 Gy (23.3Gy-106.6Gy). As part of their initial therapy 11 received pelvic external beam radiation therapy, 6 underwent surgery and 2 received other forms of intracavitary brachytherapy. Of these 12 patients, 11 achieved a complete response (CR) with the duration of CR ranging from 7 to 51 months. Actuarial disease-free survival at 3 years was 66% (S.E.=.16) and actuarial overall survival at 3 years was 91% (S.E.=.08). Median follow up for the 16 patients with recurrent pelvic malignancies was 72 months (20mo-99mo). There were 9 cases of endometrial, 3 vulvar, 3 colorectal, and 1 cervical carinomas. Fifteen of 16 received some form of surgery and radiotherapy prior to their treatment with 241 Am. Median surface dose of 241 Am was 40.3 (17.6Gy-141.7Gy). Of these 16 patients, 10 achieved a CR with the duration of CR ranging from 3 to 88 months. Actuarial disease-free survival at 5 years was 51% (S.E.=.16) and actuarial overall survival at 5 years was 43% (S.E.=.14). Complications were

  3. Selective inhibitory effects of (S)-9-(3-hydroxy-2-phosphonyl-methoxypropyl)adenine and 1-(2'-deoxy-2'-fluoro-ß-D-arabinofuranosyl)-5-iodouracil on seal herpesvirus (Phocid herpesvirus 1) infection in vitro.

    NARCIS (Netherlands)

    A.D.M.E. Osterhaus (Albert); J. Groen (Jan); E. de Clercq

    1987-01-01

    textabstractFrom a selection of 25 antiviral compounds with specific anti-herpes activity or broad-spectrum antiviral properties, two compounds, namely (S)-9-(3-hydroxy-2-phosphonyl-methoxypropyl)adenine and 1-(2'-deoxy-2'-fluoro-beta-D-arabinofuranosyl)-5-iodouracil, appeared particularly effective

  4. Comparing Cr, and N only doping with (Cr,N)-codoping for enhancing visible light reactivity of TiO2

    International Nuclear Information System (INIS)

    Li, Yuan; Wang, Wei; Qiu, Xiaofeng; Meyer, Harry M. III; Paranthaman, Mariappan Parans; Eres, Gyula; Zhang, Zhenyu; Gu, Baohua

    2011-01-01

    The photoreactivity of titania (TiO2) nanoclusters with varying levels of N or Cr-doping, or (Cr,N)-codoping, was systematically investigated using photodegradation of methyl orange in aqueous suspensions. The shifting of the TiO2 absorption edge into the visible spectral region that is primarily attributable to band gap narrowing was found to be a reliable metric for estimating the photoreactivity of the doped nanoclusters. Compared to the weak response with undoped and N-doped TiO2, Cr-doping and (Cr, N)-codoping were found to significantly enhance photodegradation of methyl orange under visible light. The initial reaction rates increase from about 0 to above 1.6 10-2 min-1 when the doping concentration of Cr in TiO2 increases from 0 to 5%. In stark contrast, under UV irradiation, doping is not only ineffective but detrimental to the photoreactivity, and all doping including N or Cr only and (Cr, N)-codoping were found to reduce photoreactivity.

  5. En route to the conductivity bottleneck in p-type CuCr1-xMxO2-ySy (M = Li, Mg)

    Science.gov (United States)

    Mandal, P.; Mazumder, N.; Akhtar, A. J.; Roy, R.; Chattopadhyay, K. K.

    2017-05-01

    We extend our material design concept [P. Mandal et al. J. Phys. D: Appl. Phys. 49, 275109, (2016); N. Mazumder et al. J. Phys. Chem. Lett. 4, 3539, (2013)] further aiming to overcome the conductivity bottleneck (1 Scm-1) in p-type transparent conducting oxide (TCO). In this work, we execute the strategy of simultaneous cationic-anionic hole doping in the prototype p-TCO CuCrO2. CuCr1-xMxO2-ySy (M = Li, Mg) is prepared by solid state heating at 1150 °C. Using Rietveld analysis, the presence of Mgcr•, Licr • and SO×areconfirmed and quantified. The diffuse reflectance (DR) spectra are acquired to determine the dominant optical gap (˜ 3.5 eV) and found to be affected little upon site selective hole doping. From temperature dependence (80 - 300 K) of DC conductivity (σdc), (Licr •+SO×)dopingcan be identified to be the more plausible alternative to reach the bottleneck threshold compared to (Mgcr •+SO×) albeit of smaller σdc at 300 K.

  6. The pure rotational spectrum of the CrS radical in its X  5Π(r) state.

    Science.gov (United States)

    Pulliam, R L; Ziurys, L M

    2010-11-07

    The pure rotational spectrum of the CrS radical has been measured in its ground X (5)Π(r) state using gas-phase millimeter/submillimeter direct absorption methods. The molecule was created by the reaction of chromium vapor, sublimed in a Broida-type oven, with hydrogen sulfide. Eleven rotational transitions were recorded for this free radical in the frequency range of 280-405 GHz; in most transitions, all five spin components were observed, and lambda-doubling was resolved in the Ω=0, 1, and 2 ladders. The data were fit with a Hund's case (a) Hamiltonian and rotational, spin-orbit, spin-spin, and lambda-doubling constants were established. Higher order spin and spin-orbit terms were essential in the analysis. The lambda-doubling constants indicate a nearby (5)Σ(+) state at an energy of ∼1500-2000 cm(-1). A bond length of 2.0781 Å was derived for CrS from the data, which is larger than the value of 2.0682 Å found for MnS by ∼0.01 Å. In contrast, the bond distance for MnO is greater than that of CrO by 0.03 Å, an illustration of the subtle differences between 3d oxide and sulfides. CrS is the second molecule in a (5)Π state that has been studied by rotational spectroscopy.

  7. Two novel penetrating coordination polymers based on flexible S-containing dicarboxylate acid with sensing properties towards Fe3+ and Cr2O72- ions

    Science.gov (United States)

    Chen, Zhiwei; Mi, Xiuna; Wang, Suna; Lu, Jing; Li, Yunwu; Li, Dacheng; Dou, Jianmin

    2018-05-01

    Two new coordination polymers (CPs), namely, {[Zn(L)(bpp)]·DMF}n (1) and {[Zn(L)(bpe)]·DMF}n (2) (L = 2,2'-[benzene-1,3-diylbis(methanediylsulfanediyl)]dibenzoic acid, bpp= 1,3-bis(4-pyridyl)propane, bpe = 1,2-Bis(4-pyridyl)ethylene, DMF = N,N-Dimethylformamide), have been solvothermally synthesized and fully characterized. Complex 1 displays a 2D→2D three-fold"false" interpenetrating structure while complex 2 possesses a novel 3-D 4-connected structure with fascinating self-penetrating moieties. The luminescence studies reveal that these complexes exhibited excellent selectivity for Fe3+ and Cr2O72- ions in DMF. The sensing mechanism was investigated through PXRD, XPS , EDS mapping measurements, and discussed in details.

  8. Microstructural control of Ti-46Al-7Nb-0.7Cr-0.2Ni-0.1Si alloy by heat treatment

    International Nuclear Information System (INIS)

    Hasegawa, Makoto; Nomura, Takuya; Haga, Hideki; Fukutomi, Hiroshi; Dlouhy, Ivo; Brno University of Technology

    2014-01-01

    The effects of holding temperature, time and cooling rate on the microstructure of Ti-46Al-7Nb-0.7Cr-0.2Ni-0.1Si (at.%) alloys are studied. Three kinds of segregations are found in the as-cast material. In back scattered electron images these segregations are observed as dark regions formed by the solidification process, bright regions with irregular shaped blocks and imaged regions of lighter contrast formed by the cooling process from β phase to α phase and from α phase to (β + γ) two phase or (α + β + γ) three phase, respectively. Addition of small amounts of Cr, Ni and Si to the Ti-45Al-7Nb alloy shifts the (β + γ) two phase state and (α + γ + β) three phase state to a lower Nb concentration range. While cooling from the α single phase state to the (β + γ) two phase or (α + β + γ) three phase states, sequential type phase transformation occurs. The amounts of Cr, Ni and Si are too small to induce the pearlitic mode of transformation. Therefore, the sequential mode of the ternary alloy containing Nb occurs. The microstructures change depending on the cooling rate from α? single phase region. Massive transformation occurs in the range of 300 K s -1 to 50 K s -1 . However, the α phase is partially retained at the cooling rate of 300 K s -1 . A fully lamellar structure appears at cooling rates lower than 10 K s -1 .

  9. Microstructural control of Ti-46Al-7Nb-0.7Cr-0.2Ni-0.1Si alloy by heat treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Makoto; Nomura, Takuya; Haga, Hideki; Fukutomi, Hiroshi [Yokohama National University (Japan). Div. of Materials Science and Chemical Engineering; Dlouhy, Ivo [Institute of Physics of Materials, Brno (Czech Republic); Brno University of Technology (Czech Republic). Inst. of Materials Science and Engineering

    2014-11-15

    The effects of holding temperature, time and cooling rate on the microstructure of Ti-46Al-7Nb-0.7Cr-0.2Ni-0.1Si (at.%) alloys are studied. Three kinds of segregations are found in the as-cast material. In back scattered electron images these segregations are observed as dark regions formed by the solidification process, bright regions with irregular shaped blocks and imaged regions of lighter contrast formed by the cooling process from β phase to α phase and from α phase to (β + γ) two phase or (α + β + γ) three phase, respectively. Addition of small amounts of Cr, Ni and Si to the Ti-45Al-7Nb alloy shifts the (β + γ) two phase state and (α + γ + β) three phase state to a lower Nb concentration range. While cooling from the α single phase state to the (β + γ) two phase or (α + β + γ) three phase states, sequential type phase transformation occurs. The amounts of Cr, Ni and Si are too small to induce the pearlitic mode of transformation. Therefore, the sequential mode of the ternary alloy containing Nb occurs. The microstructures change depending on the cooling rate from α? single phase region. Massive transformation occurs in the range of 300 K s{sup -1} to 50 K s{sup -1}. However, the α phase is partially retained at the cooling rate of 300 K s{sup -1}. A fully lamellar structure appears at cooling rates lower than 10 K s{sup -1}.

  10. Structure and magnetic properties of Cr nanoparticles and Cr2O3 nanoparticles

    International Nuclear Information System (INIS)

    Zhang, W.S.; Brueck, E.; Zhang, Z.D.; Tegus, O.; Li, W.F.; Si, P.Z.; Geng, D.Y.; Buschow, K.H.J.

    2005-01-01

    We have synthesized Cr nanoparticles by arc-discharge and Cr 2 O 3 nanoparticles by subsequent annealing the as-prepared Cr nanoparticles. The structure of these nanoparticles is studied by means of X-ray diffraction, X-ray photoelectron spectroscopy, and high-resolution transmission electron microscope. Most of the particles show a good crystal habit of well-defined cubic or orthorhombic shape, while some small particles show spherical shape. The as-prepared Cr nanoparticles have a BCC Cr core coated with a thin Cr 2 O 3 layer. Cr in the core of the particles heated at 873 K for 4 h is changed to Cr 2 O 3 . The results of magnetic measurements show that the Cr nanoparticles exhibit mainly antiferromagnetic properties, in addition to a weak-ferromagnetic component at lower fields. The weak-ferromagnetic component may be ascribed to uncompensated surface spins. For the field-cooled Cr 2 O 3 nanoparticles, an exchange bias is observed in the hysteresis loops, which can be interpreted as the exchange coupling between the uncompensated spins at the surface and the spins in the core of the Cr 2 O 3 nanoparticles

  11. [The measurement of thermal expansion coefficient of Co-Cr alloy fabricated by selective laser melting].

    Science.gov (United States)

    Tian, Xiao-mei; Zeng, Li; Wei, Bin; Huang, Yi-feng

    2015-12-01

    To investigate the thermal expansion coefficient of different processing parameters upon the Co-Cr alloy prepared by selective laser melting (SLM) technique, in order to provide technical support for clinical application of SLM technology. The heating curve of self-made Co-Cr alloy was protracted from room temperature to 980°C centigrade with DIL402PC thermal analysis instrument, keeping temperature rise rate and cooling rate at 5 K/min, and then the thermal expansion coefficient of 9 groups of Co-Cr alloy was measured from 20°C centigrade to 500°C centigrade and 600°C centigrade. The 9 groups thermal expansion coefficient values of Co-Cr alloy heated from 20°C centigrade to 500°C centigrade were 13.9×10(-6)/K,13.6×10(-6)/K,13.9×10(-6)/K,13.7×10(-6)/K,13.5×10(-6)/K,13.8×10(-6)/K,13.7×10(-6)/K,13.7×10(-6)/K,and 13.9×10(-6)/K, respectively; when heated from 20°C centigrade to 600°C centigrade, they were 14.2×10(-6)/K,13.9×10(-6)/K,13.8×10(-6)/K,14.0×10(-6)/K,14.1×10(-6)/K,14.1×10(-6)/K,13.9×10(-6)/K,14.2×10(-6)/K, and 13.7×10(-6)/K, respectively. The results showed that the Co-Cr alloy has good matching with the VITA VMK 95 porcelain powder and can meet the requirement of clinic use.

  12. Activity of Aniline Methylation over Fe-Cu-Cr Ternary Spinel Systems

    Directory of Open Access Journals (Sweden)

    Reni George

    2014-03-01

    Full Text Available A series of spinels having thegeneral formula CuCr2-xFexO4 with x=0.25,0.75, 1.25, 1.75 were prepared by co-precipitation method. The catalysts werecharacterized by various physico-chemical methods like XRD, BET, UV-DRS, SEM,EDX, TPD etc. The reaction of aniline with methanol was studied in a fixed-bedreactor system as a potential source for the production of various methylanilines. It was observed that systems possessing low ‘x’ values are highlyselective and active for N-monoalkylation of aniline leading toN-methylaniline. Reaction parameters were properly varied to optimize thereaction conditions for obtaining N-methylaniline selectively and in betteryield. Among the systems CuCr1.75Fe0.25O4 isremarkable due to its very high activity and excellent stability. Under theoptimized conditions N-methylaniline selectivity exceeded 91%. CuCr1.25Fe0.75O4gives better conversion than CuCr1.75Fe0.25O4in CuCr2-xFexO4 series. The Lewis acid sitesof the catalysts are mainly responsible for the good catalytic performance. © 2014 BCREC UNDIP. All rights reservedSubmitted: 18th July 2013; Revised: 5th November 2013; Accepted: 1st December 2013[How to Cite: George, R., George, K., Sugunan, S. (2014. Activity of Aniline Methylation over Fe-Cu-Cr Ternary Spinel Systems. Bulletin of Chemical Reaction Engineering & Catalysis, 9 (1: 39-44. (doi:10.9767/bcrec.9.1.5169.39-44][Permalink/DOI: http://dx.doi.org/10.9767/bcrec.9.1.5169.39-44] 

  13. Study of surfaces and interfaces in CdS-Cu2S and (Cd sub(x) Zn sub(1-x))S-Cu2S solar cells

    International Nuclear Information System (INIS)

    Dhere, N.G.; Dhere, R.G.; Bloss, W.H.; Schock, H.W.; Bauer, E.; Cyris, P.

    1983-01-01

    Auger microprobe was used for the analysis of interfaces and surfaces in several stages involved in the preparation of solar cells, in order to study the origin of adhesion problems and to study the formation of CdS-Cu 2 S barrier by the wet method. The detachment of the first CdS and (Cd sub(x) Zn sub(1-x))S films, during the dip process, was attributed to the contamination of Cr-Ag metallic substrates by existing chlorine from the environment next to the sea, due to long film stocking, by degasified species from the evaporating material and by the ejection of particles together with CdS vapour during deposition. The formation of conical mounds on the surface and of the CdS-Cu 2 S barrier at aproximatelly 3000 A depth in the dipped samples were observed. The migration of copper towards surface direction and the formation of a superficial thin layer of copper oxide after treatment in H 2 plasma and air heating, were also verified. (C.L.B.) [pt

  14. Structural, magnetic and transport properties of Pb{sub 2}Cr{sub 1+x}Mo{sub 1−x}O{sub 6} (−1≤x≤1/3)

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H.F. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); School of Mathematics and Physics, University of Science and Technology, Beijing 100083 (China); Cao, L.P. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Song, Y.J. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); School of Mathematics and Physics, University of Science and Technology, Beijing 100083 (China); Feng, S.M.; Shen, X. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Ni, X.D. [School of Mathematics and Physics, University of Science and Technology, Beijing 100083 (China); Yao, Y.; Wang, Y.G. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Wang, R.M. [School of Mathematics and Physics, University of Science and Technology, Beijing 100083 (China); Jin, C.Q. [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Yu, R.C., E-mail: rcyu@aphy.iphy.ac.cn [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049 (China)

    2017-02-15

    Pb{sub 2}Cr{sub 1+x}Mo{sub 1-x}O{sub 6} (−1≤x≤1/3) samples were synthesized via a high pressure and high temperature route. X-ray diffraction results suggest the samples crystallize in a disordered double perovskite structure (Pm-3m). X-ray photoemission spectroscopy results confirm the presence of Mo{sup 4+} for x=−1 and Mo{sup 6+} for x=1/3. The measured magnetic and electrical properties exhibit systematic change with increasing x. - Highlights: • A series of Pb{sub 2}Cr{sub 1+x}Mo{sub 1−x}O{sub 6} samples were synthesized under high pressure. • Magnetic and electrical properties of the series samples were investigated. • Valence states of Cr and Mo were determined through the analyses of XRD and XPS results. • Ground state of PbMoO{sub 3} were determined through the transport study and first-principles calculations.

  15. Modification of tribology and high-temperature behavior of Ti-48Al-2Cr-2Nb intermetallic alloy by laser cladding

    International Nuclear Information System (INIS)

    Liu Xiubo; Wang Huaming

    2006-01-01

    In order to improve the tribology and high-temperature oxidation properties of the Ti-48Al-2Cr-2Nb intermetallic alloy simultaneously, mixed NiCr-Cr 3 C 2 precursor powders had been investigated for laser cladding treatment to modify wear and high-temperature oxidation resistance of the material. The alloy samples were pre-placed with NiCr-80, 50 and 20%Cr 3 C 2 (wt.%), respectively, and laser treated at the same parameters, i.e., laser output power 2.8 kW, beam scanning speed 2.0 mm/s, beam dimension 1 mm x 18 mm. The treated samples underwent tests of microhardness, wear and high-temperature oxidation. The results showed that laser cladding with different constitution of mixed precursor NiCr-Cr 3 C 2 powders improved surface hardness in all cases. Laser cladding with NiCr-50%Cr 3 C 2 resulted in the best modification of tribology and high-temperature oxidation behavior. X-ray diffraction (XRD), optical microscope (OM), scanning electron microscopy (SEM) and energy-dispersive spectrometer (EDS) analyses indicated that the formation of reinforced Cr 7 C 3 , TiC and both continuous and dense Al 2 O 3 , Cr 2 O 3 oxide scales were supposed to be responsible for the modification of the relevant properties. As a result, the present work had laid beneficial surface engineering foundation for TiAl alloy applied as future light weight and high-temperature structural candidate materials

  16. Neutron diffraction studies of the Na-ion battery electrode materials NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Yahia, H. Ben [Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, P.O. Box 5825 Doha (Qatar); Essehli, R., E-mail: ressehli@qf.org.qa [Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, P.O. Box 5825 Doha (Qatar); Avdeev, M. [Australian Nuclear Science and Technology Organisation, New Illawarra Road, Lucas Heights NSW 2234 (Australia); Park, J-B.; Sun, Y-K. [Department of Energy Engineering Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Al-Maadeed, M.A. [Center for Advanced Materials (CAM), Qatar University, 2713 Doha (Qatar); Belharouak, I., E-mail: ibelharouak@qf.org.qa [Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, P.O. Box 5825 Doha (Qatar)

    2016-06-15

    The new compounds NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} were synthesized by sol-gel method and their crystal structures were determined by using neutron powder diffraction data. These compounds were characterized by galvanometric cycling and cyclic voltammetry. NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} crystallize with a stuffed α-CrPO{sub 4}-type structure. The structure consists of a 3D-framework made of octahedra and tetrahedra that are sharing corners and/or edges generating channels along [100] and [010], in which the sodium atoms are located. Of significance, in the structures of NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} a statistical disorder Ni{sup 2+}/Cr{sup 3+} was observed on both the 8g and 4a atomic positions, whereas in NaCoCr{sub 2}(PO{sub 4}){sub 3} the statistical disorder Co{sup 2+}/Cr{sup 3+} was only observed on the 8g atomic position. When tested as negative electrode materials, NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} delivered specific capacities of 352, 385, and 368 mA h g{sup −1}, respectively, which attests to the electrochemical activity of sodium in these compounds. - Highlights: • NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} were synthesized by sol-gel method. • The crystal structures were determined by using neutron powder diffraction data. • The three compounds crystallize with a stuffed α-CrPO{sub 4}-type structure. • The three compounds were tested as anodes in sodium-ion batteries. • Relatively high specific capacities were obtained for these compounds.

  17. Magnetic properties and phase stability of half-metal-type Co2Cr1-xFexGa alloys

    International Nuclear Information System (INIS)

    Kobayashi, K.; Umetsu, R.Y.; Fujita, A.; Oikawa, K.; Kainuma, R.; Fukamichi, K.; Ishida, K.

    2005-01-01

    The magnetic properties and phase stability of half-metal-type Co 2 Cr 1-x Fe x Ga alloys were investigated by differential scanning calorimetry (DSC), in a superconducting quantum interference device (SQUID) magnetometer and in a vibrating sample magnetometer (VSM), and by transmission electron microscopy (TEM). It was found that the L2 1 -type single-phase is obtainable for the entire concentration of x and that the value of the saturation magnetic moment M s at 4.2K in the lower composition range of x is in agreement with the generalized Slater-Pauling line, while it is rather larger than the generalized Slater-Pauling line above x=0.6. The Curie temperature T c monotonically increases, whereas the transition temperature from the L2 1 - to B2-type phase T t B2/L2 1 is almost constant at 1082+/-13K with increasing x

  18. Treatment of selected primary gynecologic and pelvic malignancies with {sup 241}Americium

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Joyce Y; Peschel, Richard E; Kacinski, Barry; Nath, Ravinder; Pourang, Rauman; Roberts, Kenneth; Fischer, Diana; Chambers, Joseph; Schwartz, Peter E; Wilson, Lynn

    1995-07-01

    Purpose: To evaluate the efficacy of encapsulated {sup 241}Am in the treatment of primary gynecological malignancies and in previously irradiated patients with recurrent disease in the pelvis. Materials and Methods: Encapsulated {sup 241}Am primarily emits 60keV photons which are effectively shielded by thin layers of high atomic number materials. Dose distributions in water are similar to those produced by Cs-137 photons but with a half-value layer that is considerably less. Cases of 28 patients (12-primary, 16-recurrent) who have been treated with {sup 241}Am at the Yale University School of Medicine since 1986 were retrospectively reviewed. Data concerning dosimetry, disease site, prior treatment, recurrence, disease-free survival, overall survival, and complications were evaluated. Results: Median follow up for the 12 patients with primary gynecological tumors was 19 months (7mo-51mo). There were 6 vulvar, 3 vaginal, 2 cervical and 1 endometrial carcinomas. Median surface dose of {sup 241}Am was 42.2 Gy (23.3Gy-106.6Gy). As part of their initial therapy 11 received pelvic external beam radiation therapy, 6 underwent surgery and 2 received other forms of intracavitary brachytherapy. Of these 12 patients, 11 achieved a complete response (CR) with the duration of CR ranging from 7 to 51 months. Actuarial disease-free survival at 3 years was 66% (S.E.=.16) and actuarial overall survival at 3 years was 91% (S.E.=.08). Median follow up for the 16 patients with recurrent pelvic malignancies was 72 months (20mo-99mo). There were 9 cases of endometrial, 3 vulvar, 3 colorectal, and 1 cervical carinomas. Fifteen of 16 received some form of surgery and radiotherapy prior to their treatment with {sup 241}Am. Median surface dose of {sup 241}Am was 40.3 (17.6Gy-141.7Gy). Of these 16 patients, 10 achieved a CR with the duration of CR ranging from 3 to 88 months. Actuarial disease-free survival at 5 years was 51% (S.E.=.16) and actuarial overall survival at 5 years was 43% (S

  19. Structural, thermal, and magnetic study of solvation processes in spin-crossover [Fe(bpp)(2)][Cr(L)(ox)(2)](2).nH(2)O complexes.

    Science.gov (United States)

    Clemente-León, Miguel; Coronado, Eugenio; Giménez-López, M Carmen; Romero, Francisco M

    2007-12-24

    The influence of lattice water in the magnetic properties of spin-crossover [Fe(bpp)2]X2.nH2O salts [bpp = 2,6-bis(pyrazol-3-yl)pyridine] is well-documented. In most cases, it stabilizes the low-spin state compared to the anhydrous compound. In other cases, it is rather the contrary. Unraveling this mystery implies the study of the microscopic changes that accompany the loss of water. This might be difficult from an experimental point of view. Our strategy is to focus on some salts that undergo a nonreversible dehydration-hydration process without loss of crystallinity. By comparison of the structural and magnetic properties of original and rehydrated samples, several rules concerning the role of water at the microscopic level can be deduced. This paper reports on the crystal structure, thermal studies, and magnetic properties of [Fe(bpp)2][Cr(bpy)(ox)2]2.2H2O (1), [Fe(bpp)2][Cr(phen)(ox)2]2.0.5H2O.0.5MeOH (2), and [Fe(bpp)2][Cr(phen)(ox)2]2.5.5H2O.2.5MeOH (3). Salt 1 contains both high-spin (HS) and low-spin (LS) Fe2+ cations in a 1:1 ratio. Dehydration yields the anhydrous spin-crossover compound with T1/2 downward arrow = 353 K and T1/2 upward arrow = 369 K. Rehydration affords the dihydrate [Fe(bpp)2][Cr(bpy)(ox)2]2.2H2O (1r) with 100% HS Fe2+ sites. Salt 2 also contains both HS and LS Fe2+ cations in a 1:1 ratio. Dehydration yields the anhydrous spin-crossover compound with T1/2 downward arrow = 343 K and T1/2 upward arrow = 348 K. Rehydration affords [Fe(bpp)2][Cr(phen)(ox)2]2.0.5H2O (2r) with 72% Fe2+ sites in the LS configuration. The structural, magnetic, and thermal properties of these rehydrated compounds 1r and 2r are also discussed. Finally, 1 has been dehydrated and resolvated with MeOH to give [Fe(bpp)2][Cr(bpy)(ox)2]2.MeOH (1s) with 33% HS Fe2+ sites. The influence of the guest solvent in the Fe2+ spin state can anticipate the future applications of these compounds in solvent sensing.

  20. Phase II study of tailored S-1 monotherapy with a 1-week interval after a 2-week dosing period in elderly patients with advanced non-small cell lung cancer.

    Science.gov (United States)

    Goto, Hisatsugu; Okano, Yoshio; Machida, Hisanori; Hatakeyama, Nobuo; Ogushi, Fumitaka; Haku, Takashi; Kanematsu, Takanori; Urata, Tomoyuki; Kakiuchi, Soji; Hanibuchi, Masaki; Sone, Saburo; Nishioka, Yasuhiko

    2018-01-01

    S-1 is an oral fluoropyrimidine that is active in the treatment of non-small cell lung cancer (NSCLC); however, an optimal treatment schedule and appropriate dose adjustments of S-1 in elderly patients have not yet been established. We conducted a phase II trial to evaluate the efficacy and safety of a 2-week S-1 monotherapy treatment followed by a 1-week interval as a first-line treatment of elderly NSCLC patients, by adjusting the dose based on the individual creatinine clearance (Ccr) and body surface area (BSA). The primary endpoint was the disease control rate. Forty patients were enrolled. The disease control and response rates were 89.5% (95% confidence interval [CI] = 79.8-99.2) and 7.9% (95% CI = 0.0-16.4), respectively. The median progression-free survival and overall survival times were 4.4 months (95% CI = 4.2-8.5) and 17.0 months (95% CI = 11.2-18.7), respectively. Neutropenia, anorexia, hyponatremia, hypokalemia, and pneumonia of grade ≥ 3 occurred in 5.0%, 7.5%, 5.0%, 2.5%, and 2.5% of patients, respectively. Among the patient-reported outcomes, most of the individual factors in the patients' quality of life, including upper intestine-related symptoms improved with the treatment, except for dyspnea, which slightly albeit continuously worsened throughout the study. In elderly patients with previously untreated advanced NSCLC, a 2-week S-1 monotherapy treatment, tailored to both the Ccr and BSA, with a 1-week interval was well tolerated and demonstrated promising efficacy. This study was registered at the University Hospital Medical Information Network (UMIN) Center (ID: UMIN000002035), Japan. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  1. Accumulation and distribution patterns of trivalent 51Cr in rats

    International Nuclear Information System (INIS)

    Zimakov, I.E.; Sin'kov, V.I.; Zakharova, L.L.

    1986-01-01

    The effect of stable isotope of trivalent chromium on the behaviour of its radioactive isotope 54 Cr in the feed-animal food chain is studied. It is shown that the doses of stable chromium of 5 mg/kg and less practically exert no influence on the regularities of 51 Cr behaviour in the organism animals statistically the reliable effect on the Cr 51 level in separate organs and tissues of animals is noted at the doses of stable isotope carrier of 20 and 40 mg/kg. To establish the stable carrier effect f 1 and f 2 their values have been compared in case of 51 Cr single intake without carrier and with stable isotope carrier in the amount of 50 mg/kg. In the last case for kidneys the Ff 2 value decreased and became 0.04 whereas for the spleen practically remained the same

  2. Electron transport in all-Heusler Co2CrSi/Cu2CrAl/Co2CrSi device, based on ab-initio NEGF calculations

    Science.gov (United States)

    Mikaeilzadeh, L.; Pirgholi, M.; Tavana, A.

    2018-05-01

    Based on the ab-initio non-equilibrium Green's function (NEGF) formalism based on the density functional theory (DFT), we have studied the electron transport in the all-Heusler device Co2CrSi/Cu2CrAl/Co2CrSi. Results show that the calculated transmission spectra is very sensitive to the structural parameters and the interface. Also, we obtain a range for the thickness of the spacer layer for which the MR effect is optimum. Calculations also show a perfect GMR effect in this device.

  3. Annealing effect on the structural and optical properties of Cr/α-Cr2O3 monodispersed particles based solar absorbers

    International Nuclear Information System (INIS)

    Khamlich, S.; McCrindle, R.; Nuru, Z.Y.; Cingo, N.; Maaza, M.

    2013-01-01

    Graphical abstract: A cost-effective and environmentally friendly green chemical method, the so-called aqueous chemical growth (ACG) method, was used to deposit chromium/alpha-chromium(III) oxide, Cr/α-Cr 2 O 3 , monodispersed particles, for solar absorbers applications. Highlights: ► Cr/α-Cr 2 O 3 have been deposited by the aqueous chemical growth (ACG) method. ► High temperature annealing affects the optical selectivity of the deposited particles. ► Oxygen diffusion to the interface at high temperature results in the oxidization of the substrate. - Abstract: A cost-effective and environmentally friendly green chemical method, the so-called aqueous chemical growth (ACG) method, was used to deposit chromium/alpha-chromium(III) oxide, Cr/α-Cr 2 O 3 , monodispersed particles, for solar absorbers applications. The deposited particles were annealed at various temperatures in a hydrogen atmosphere for 2 h to study the annealing temperature dependence of the structural, chemical and optical properties of the particles grown on tantalum substrates. The deposited Cr/α-Cr 2 O 3 was characterized by X-ray diffraction (XRD), attenuated total reflection (ATR), scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), and diffuse reflectance UV–vis–NIR spectroscopy. The XRD and ATR analysis indicated that by increasing annealing temperature, the particles crystallinity was improved and Ta 2 O 5 was formed around 600 °C, due to the fast oxygen diffusion from the deposited α-Cr 2 O 3 toward the tantalum substrate. The optical measurements show that samples annealed at 400 and 500 °C exhibit the targeted high absorbing optical characteristics of “Black chrome”, while those annealed below 400 °C and above 500 °C show a significant low absorptivity and high emissivity.

  4. Effect of Chromium on Corrosion Behavior of P110 Steels in CO2-H2S Environment with High Pressure and High Temperature

    Directory of Open Access Journals (Sweden)

    Jianbo Sun

    2016-03-01

    Full Text Available The novel Cr-containing low alloy steels have exhibited good corrosion resistance in CO2 environment, mainly owing to the formation of Cr-enriched corrosion film. In order to evaluate whether it is applicable to the CO2 and H2S coexistence conditions, the corrosion behavior of low-chromium steels in CO2-H2S environment with high pressure and high temperature was investigated using weight loss measurement and surface characterization. The results showed that P110 steel suffered localized corrosion and both 3Cr-P110 and 5Cr-P110 steels exhibited general corrosion. However, the corrosion rate of 5Cr-P110 was the highest among them. The corrosion process of the steels was simultaneously governed by CO2 and H2S. The outer scales on the three steels mainly consisted of FeS1−x crystals, whereas the inner scales on Cr-containing steels comprised of amorphous FeS1−x, Cr(OH3 and FeCO3, in contrast with the amorphous FeS1−x and FeCO3 mixture film of P110 steel. The more chromium the steel contains, the more chromium compounds the corrosion products contain. The addition of chromium in steels increases the uniformity of the Cr-enriched corrosion scales, eliminates the localized corrosion, but cannot decrease the general corrosion rates. The formation of FeS1−x may interfere with Cr-enriched corrosion scales and lowering the corrosion performance of 3Cr-P110 and 5Cr-P110 steels.

  5. Effect of Chromium on Corrosion Behavior of P110 Steels in CO2-H2S Environment with High Pressure and High Temperature

    Science.gov (United States)

    Sun, Jianbo; Sun, Chong; Lin, Xueqiang; Cheng, Xiangkun; Liu, Huifeng

    2016-01-01

    The novel Cr-containing low alloy steels have exhibited good corrosion resistance in CO2 environment, mainly owing to the formation of Cr-enriched corrosion film. In order to evaluate whether it is applicable to the CO2 and H2S coexistence conditions, the corrosion behavior of low-chromium steels in CO2-H2S environment with high pressure and high temperature was investigated using weight loss measurement and surface characterization. The results showed that P110 steel suffered localized corrosion and both 3Cr-P110 and 5Cr-P110 steels exhibited general corrosion. However, the corrosion rate of 5Cr-P110 was the highest among them. The corrosion process of the steels was simultaneously governed by CO2 and H2S. The outer scales on the three steels mainly consisted of FeS1−x crystals, whereas the inner scales on Cr-containing steels comprised of amorphous FeS1−x, Cr(OH)3 and FeCO3, in contrast with the amorphous FeS1−x and FeCO3 mixture film of P110 steel. The more chromium the steel contains, the more chromium compounds the corrosion products contain. The addition of chromium in steels increases the uniformity of the Cr-enriched corrosion scales, eliminates the localized corrosion, but cannot decrease the general corrosion rates. The formation of FeS1−x may interfere with Cr-enriched corrosion scales and lowering the corrosion performance of 3Cr-P110 and 5Cr-P110 steels. PMID:28773328

  6. Magnetodielectric effect in CoCr2-XFeXO4

    International Nuclear Information System (INIS)

    Bao Huixin; Yang Sen; Ren Xiaobing

    2011-01-01

    Conventional multiferroics show the multiferroic behaviors below two successive transitions (a ferroelectric transition and a ferromagnetic transition). In the present study, we report the magneto-dielectric (MD) effect (both in-plane and out-of-plane) in CoCr 2-X Fe X O 4 which undergoes only a ferromagnetic transition. We found the MD effect in the pure ferromagnetic phase (T S C ) of CoCr 2 O 4 . And such MD effect is temperature dependent. The magnitude of the MD effect gradually decreases with approaching Curie temperature (T C ) and finally becomes zero at T C . With doping Fe into CoCr 2 O 4 , we found the magnitude of MD effect increases and the MD effect exists in a wider temperature region because T C increases and T S decrease with doping Fe. Our results show the coupling between the ferromagnetic and ferroelectric orders. It suggests that both the ferromagnetic and ferroelectric properties originate from the same transition.

  7. Gastric and renal effects of COX-2 selective and non-selective NSAIDs in rats receiving low-dose aspirin therapy

    Directory of Open Access Journals (Sweden)

    Marcella Goetz MORO

    Full Text Available Abstract The consumption of low-dose aspirin (LDA to prevent cardiovascular disease continues to increase worldwide. Consequently, the number of chronic LDA users seeking dental procedures that require complementary acute anti-inflammatory medication has also grown. Considering the lack of literature evaluating this interaction, we analyzed the gastric and renal effects caused by a selective COX-2 inhibitor (etoricoxib and a non-selective COX-2 inhibitor (ibuprofen nonsteroidal anti-inflammatory drug (NSAID in rats receiving chronic LDA therapy. Male Wistar rats were divided into six experimental groups (carboxymethylcellulose (CMC - vehicle; LDA; LDA + ibuprofen; ibuprofen; LDA + etoricoxib; and etoricoxib and submitted to long-term LDA therapy with a subsequent NSAID administration for three days by gavage. After the experimental period, we analyzed gastric and renal tissues and quantified serum creatinine levels. The concomitant use of LDA with either NSAID induced the highest levels of gastric damage when compared to the CMC group (F = 20.26, p 0.05. These results suggest that even the acute use of an NSAID (regardless of COX-2 selectivity can induce gastric damage when combined with the long-term use of low-dose aspirin in an animal model. Additional studies, including clinical assessments, are thus needed to clarify this interaction, and clinicians should be careful of prescribing NSAIDs to patients using LDA.

  8. Crystal structure and magnetic properties of the Cr-doped spiral antiferromagnet BiMnFe2O6

    International Nuclear Information System (INIS)

    Batuk, Dmitry; De Dobbelaere, Christopher; Tsirlin, Alexander A.; Abakumov, Artem M.; Hardy, An; Van Bael, Marlies K.; Greenblatt, Martha; Hadermann, Joke

    2013-01-01

    Graphical abstract: - Highlights: • The substitution of Cr for Mn in BiMnFe 2 O 6 is possible by the solution–gel method. • The BiCr x Mn 1−x Fe 2 O 6 solid solution is obtained for the x values up to 0.3. • Increasing Cr content lowers the temperature of the antiferromagnetic ordering. - Abstract: We report the Cr 3+ for Mn 3+ substitution in the BiMnFe 2 O 6 structure. The BiCr x Mn 1−x Fe 2 O 6 solid solution is obtained by the solution–gel synthesis technique for the x values up to 0.3. The crystal structure investigation using a combination of X-ray powder diffraction and transmission electron microscopy demonstrates that the compounds retain the parent BiMnFe 2 O 6 structure (for x = 0.3, a = 5.02010(6)Å, b = 7.06594(7)Å, c = 12.6174(1)Å, S.G. Pbcm, R I = 0.036, R P = 0.011) with only a slight decrease in the cell parameters associated with the Cr 3+ for Mn 3+ substitution. Magnetic susceptibility measurements suggest strong similarities in the magnetic behavior of BiCr x Mn 1−x Fe 2 O 6 (x = 0.2; 0.3) and parent BiMnFe 2 O 6 . Only T N slightly decreases upon Cr doping that indicates a very subtle influence of Cr 3+ cations on the magnetic properties at the available substitution rates

  9. Effects of the Cr2O3 Content on the Viscosity of CaO-SiO2-10 Pct Al2O3-Cr2O3 Quaternary Slag

    Science.gov (United States)

    Wu, Tuo; Zhang, Yanling; Yuan, Fang; An, Zhuoqing

    2018-04-01

    The present study experimentally investigates the effect of Cr2O3 on the viscosity of molten slags. The viscosities of CaO-SiO2-10 pct Al2O3-Cr2O3 quaternary slags with two different binary basicities (R, basic slag with R = 1.2 and acidic slag with R = 0.8) were measured by the rotating cylindrical method from 1813 K to 1953 K (1540 °C to 1680 °C). The results showed that the viscosity of both types of slag decreased as the Cr2O3 content increased, but the viscosity of acidic slags exhibited a greater decrease. The slags showed good Newtonian behavior at such high temperatures. Cr2O3 could act as a network modifier to simplify the Si-O-Si tetrahedral structure, as verified by the Raman spectral analysis, which was consistent with the decreasing trend of viscosity. The activation energy of viscous flow decreased slightly with increasing Cr2O3, but increasing the basicity seemed to be more effective in decreasing the viscosity than adding Cr2O3.

  10. In silico CrNF, a half-metallic ferromagnetic nitride–fluoride mimicking CrO2

    International Nuclear Information System (INIS)

    Matar, Samir F.

    2014-01-01

    Isoelectronic with CrO 2 , CrNF is proposed in silico based on rutile derived structures with DFT computations. The ground state structure defined from cohesive energies is of MgUO 4 -type, characterized by short covalent Cr–N and long ionic Cr–F distances. Like CrO 2 it is a half-metallic ferromagnet with M=2 μ B /FU integer magnetization with reduced band gap at minority spins. Major difference of magnetic response to pressure characterizes CrNF as a soft ferromagnet versus hard magnetic CrO 2 . The chemical bonding properties point to prevailing covalent Cr–N versus ionic Cr–F bonding. Different synthesis routes are examined. - Highlights: • DFT identification of CrNF is based on isoelectronicity and rutile derivatives. • Similarly to CrO 2 , CrNF is a half-metallic ferromagnet with reduced band gap. • Strong pressure dependence of magnetization of CrNF oppositely to CrO 2 . • Covalent Cr–N bonding prevails in spite of the presence of ionic Cr–F. • Cohesive energies favor the synthesis for which protocols are proposed

  11. Interaction of complement-solubilized immune complexes with CR1 receptors on human erythrocytes. The binding reaction

    DEFF Research Database (Denmark)

    Jepsen, H H; Svehag, S E; Jarlbaek, L

    1986-01-01

    showed no binding. IC solubilized in 50% human serum in the presence of autologous RBC bound rapidly to RBC-CR1, with maximal binding within less than 1 min at 37 degrees C. Release of CR1-bound IC under these conditions occurred slowly, requiring more than 30 min. Only binding of 'partially' solubilized...... of an intact classical pathway in preparing the IC for binding to RBC-CR1. C-solubilized IC could be absorbed to solid-phase conglutinin or antibody to C3c and C4c, and these ligands were able to inhibit the binding of solubilized IC to RBC. Heparin also exerted a marked, dose-dependent inhibitory effect...

  12. Effects of water vapor on protectiveness of Cr2O3 scale at 1073 K

    Science.gov (United States)

    Arifin, S. K.; Hamid, M.; Berahim, A. N.; Ani, M. H.

    2018-01-01

    Fe-Cr alloy is commonly being used as boiler tube’s material. It is subjected to prolonged exposure to water vapor oxidation. The ability to withstand high temperature corrosion can normally be attributed to the formation of a dense and slow growing Cr-rich-oxide scale known as chromia, Cr2O3 scale. However, oxidation may limit the alloy’s service lifetime due to decreasing of its protectiveness capability. This paper is to presents an experimental study of thermo gravimetric and Fourier transform infrared analysis of Cr2O3 at 1073 K in dry and humid environment. Samples were used from commercially available Cr2O3 powder. It was cold-pressed into pellet shape of 12 mm diameter and 3 mm thick with hydraulic press for 40 min at 48 MPa. It then sintered at 1173 K in inert gas environment for 8 h. The samples are cooled and placed in 5 mm diameter platinum pan. It is subjected to reaction in dry and wet environment at 1073 K by applying 100%-Ar and Ar-5%H2 gas. Each reaction period is 48 h utilizing Thermo Gravimetric Analyzer, TGA to quantify the mass changes. After the reaction, the samples then characterized with Fourier Transform Infrared Spectroscopy, FT-IR and Field Emission Electron Scanning Microscopy, FE-SEM. The TGA result shows mass decreasing ratio of Cr2O3 in wet (PH2O = 9.5x105Pa) and dry environment is at a factor of 1.2 while parabolic rate at 1.4. FT-IR results confirmed that water vapor significantly broaden the peaks, thus promotes the volatilization of Cr2O3 in wet sample. FESEM shows mostly packed and intact in dry while in wet sample, slightly porous particle arrangement compare to dry. It is concluded that water vapor species decreased Cr2O3 protectiveness capability.

  13. Relaxation of magnetization in spinel CuCrZrS4

    International Nuclear Information System (INIS)

    Ito, Masakazu; Furuta, Tatsuya; Terada, Norio; Ebisu, Shuji; Nagata, Shoichi

    2012-01-01

    We studied time t dependence of magnetization M(t) of thiospinel CuCrZrS 4 which has a spin-glass freezing. The relaxation of M is observed below T f ≃6K and shows a logarithmic time dependence. This means that a relaxation time τ of CuCrZrS 4 is distributed in a wide time range. Randomness of an arrangement of the Cr and Zr ions in CuCrZrS 4 probably gives rise to a distribution of τ. Temperature T dependence of magnetic viscosity β(T) is understood by a conventional after-effect model with a box-type distribution function of τ.

  14. Hydrogen storage study on Ti2CrV and ZrFe1.8V0.2 composite system

    International Nuclear Information System (INIS)

    Banerjee, S.; Kumar, A.; Pillai, C.G.S.; Sudarsan, V.

    2012-01-01

    Ti 2 CrV is reported to have one of the highest hydrogen storage capacities (more than 4 wt. %) among the bcc phase transition metal alloys. It has been found from the earlier study that Ti 2 CrV alloy shows quite good hydrogen absorption property but the desorption temperature is on the higher side. The in-situ temperature programmed desorption profile shows that the hydrogen desorption starts from 120℃ and the desorption peak comes at 180℃, which is slightly high for the vehicular application. On the other hand ZrFe 1.8 V 0.2 Laves phase alloy has low hydrogen absorption capacity, but at the room temperature it can desorp all its hydrogen. The pressure composition isotherm of ZrFe 1.8 V 0.2 alloy generated during the experiment shows the typical characteristics of the room temperature reversible hydride. The in-situ temperature programmed desorption shows that the hydride can desorb all the hydrogen below room temperature

  15. Effects of alloying and temperature on the high-temperature oxidation of Cr-Cr{sub 2}Nb

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, P.F.; DeVan, J.H. [Oak Ridge National Lab., TN (United States); Carson, L.J. [Lincoln Univ., PA (United States)

    1993-06-01

    Effects of alloying additions and temperature on isothermal and cyclic oxidation resistance of Cr-Cr{sub 2}Nb alloys were examined for air exposures. An isothermal exposure temperature of 1100C led to rapid reaction of binary Cr-12 at.% Nb as manifested a high oxidation rate and nonprotective behavior. Generally parabolic kinetics, complicated by some isothermal scale cracking, were observed at 900--1000C. Scale damage was exacerbated by thermal cycling. The addition of 8 at.% Al to Cr-12 at.% Nb did not effect cyclic oxidation resistance, but there was some evidence that scale adherence on Cr-6 at.% Nb-8 at.% Al was better than that for binary Cr-6 at.% Nb. Alloying additions of Al (up to 18 at.%) or Re (2 at.%) did not improve the isothermal oxidation resistance of Cr-12 at.% Nb. However, the tendency for scale damage during both isothermal and thermal cycling exposures suggests that alloying additions that specifically improve scale plasticity or modify growth stresses could be effective for Cr-Nb alloys. 10 refs, 9 figs, 1 tab.

  16. Uncertainties in contamination level and in doses after exposure to actinide aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Fritsch, P.; Berard, P.; Frank, D.; Ansoborlo, E.; Fottorino, R.; Challeton-Devatayre, C.; Miele, A.; Blanchin, N.; Raynaud, P.; Piechowski, J. [CEA Cadarache, MEDOR, A. Miele, SST, 13 - Saint Paul lez Durance (France)

    2006-07-01

    A task group named 'Methodes Dosimetriques de Reference' (M.E.D.O.R.) has been created recently to provide didactic tools for dose estimation from bioassay data obtained after occupational exposure. This task group is focused on 1) application limits of the available models, 2) uncertainties in radionuclide biokinetics and in doses, and 3) identification of the main parameters involved in these uncertainties. First, uncertainties in biokinetics of {sup 239}Pu (thoracic retention and excretion) and in doses have been estimated after acute inhalation of PuO{sub 2} (A.M.A.D. 5{mu}m, type S). This was performed either when the activity of the inhaled aerosol (case 1) or the thoracic retention on day 1 (case 2) could be measured. Variability assigned to the different parameters of the ICRP models was that previously reported. After simulation, a lognormal distribution of the results was observed so that uncertainties can be expressed as 95 % Confidence interval Ratio (C.R.={sigma}{sub g}{sup 4}). In case 1, most of the uncertainties were due to aerosol deposition and remained nearly constant for 1000 days after exposure (thoracic, faecal and urinary C.R. of 8, 6 -30 and 10, respectively). In contrast, in case 2, thoracic C.R. gradually increased from 1.5 to 5, faecal C.R. was similar to that of case 1 up to 20 days and then sharply decreased to about 3, whereas C.R. of urinary excretion remained similar to case 1 throughout the 1000 day period. Uncertainties in D.P.U.I. were much higher in case 1 (C.R.=7) than in case 2 (C.R.=2) and were both mainly due to the uncertainties in thoracic equivalent doses. Second, different bioassay data were analysed to verify if the observed results were within the C.R. previously calculated for case 2. Two cases are provided as examples which appeared out of this range. The first one corresponds to an acute exposure to PuO{sub 2} aerosols which was followed for about 20 years. Fit analysis has shown a low value of the slow

  17. Seguridad de la terapia de interferón alfa 2b recombinante más ribavirina en la hepatitis crónica C

    Directory of Open Access Journals (Sweden)

    Yoan Antonio Sánchez Rodríguez

    2011-03-01

    Full Text Available INTRODUCCIÓN: la hepatitis crónica C ha adquirido rango de pandemia. El virus de la hepatitis C se ha convertido en la causa principal de hepatitis crónica, cirrosis hepática, hepatocarcinoma, y trasplante de hígado a nivel mundial. OBJETIVO: identificar los efectos adversos asociados a la terapia combinada interferón alfa 2b recombinante más ribavirina durante la evolución del tratamiento y hasta 8 semanas después de finalizado, así como los principales efectos asociados a salidas temporales o definitivas de esta terapia. MÉTODOS: estudio de farmacovigilancia cuya serie estuvo conformada por 122 pacientes con hepatitis crónica C atendidos en el Instituto de Gastroenterología desde mayo de 2001 hasta mayo de 2006. Se utilizó interferón alfa 2b recombinante (3 millones de unidades 3 veces por semana más ribavirina (1 000 o 1 200 mg diarios en dependencia del peso corporal durante 48 semanas. RESULTADOS: el 88,5 % del total de casos presentó efectos adversos; de ellos el 79,5 % correspondió al síndrome seudogripal, seguido de manifestaciones hematológicas, neuropsiquiátricas, gastrointestinales, entre otras menos frecuentes. El 6,6 % de la serie presentó salidas temporales del tratamiento por efecto adverso distinto de la anemia y 4 pacientes, salidas definitivas del estudio, tres por anemia hemolítica severa y uno con hipertiroidismo no controlable. CONCLUSIONES: la terapia combinada interferón alfa 2b recombinante más ribavirina resulta segura, donde el mayor número de casos presentó síndrome seudogripal como efecto adverso más frecuente. Las manifestaciones hematológicas asociadas a las salidas definitivas del estudio permitieron recomendar seguimiento estricto de la hemoglobina y profundizar en el diagnóstico y tratamiento de los principales efectos adversos presentes en otros sistemas y asociados a esta terapia.

  18. Preliminary Microstructural and Microscratch Results of Ni-Cr-Fe and Cr3C2-NiCr Coatings on Magnesium Substrate

    Science.gov (United States)

    Istrate, B.; Munteanu, C.; Lupescu, S.; Benchea, M.; Vizureanu, P.

    2017-06-01

    Thermal coatings have a large scale application in aerospace and automotive field, as barriers improving wear mechanical characteristics and corrosion resistance. In present research, there have been used two types of coatings, Ni-Cr-Fe, respectively Cr3C2-NiCr which were deposited on magnesium based alloys (pure magnesium and Mg-30Y master alloy). There have been investigated the microstructural aspects through scanning electronic microscopy and XRD analysis and also a series of mechanical characteristics through microscratch and indentation determinations. The results revealed the formation of some adherent layers resistant to the penetration of the metallic indenter, the coatings did not suffer major damages. Microstructural analysis highlighted the formation of Cr3C2, Cr7C3, Cr3Ni2, Cr7Ni3, FeNi3, Cr-Ni phases. Also, the apparent coefficient of friction for Ni-Cr-Fe coatings presents superior values than Cr3C2-NiCr coatings.

  19. Contribution of semen trait selection, artificial insemination technique, and semen dose to the profitability of pig production systems: A simulation study.

    Science.gov (United States)

    Gonzalez-Pena, Dianelys; Knox, Robert V; Rodriguez-Zas, Sandra L

    2016-01-15

    The economic impact of selection for semen traits on pig production systems and potential interaction with artificial insemination (AI) technique and semen dose remains partially understood. The objectives of this study were to compare the financial indicators (gross return, net profit, cost) in a three-tier pig production system under one of two selection strategies: a traditional strategy including nine paternal and maternal traits (S9) and an advanced strategy that adds four semen traits (S13). Maternal traits included the number of pigs born alive, litter birth weight, adjusted 21-day litter weight, and the number of pigs at 21 days, and paternal traits included days to 113.5 kg, back fat, average daily gain, feed efficiency, and carcass lean percentage. The four semen traits included volume, concentration, progressive motility of spermatozoa, and abnormal spermatozoa. Simultaneously, the impact of two AI techniques and a range of fresh refrigerated semen doses including cervical AI with 3 × 10(9) (CAI3) and 2 × 10(9) (CAI2) sperm cells/dose, and intrauterine AI with 1.5 × 10(9) (IUI1.5), 0.75 × 10(9) (IUI0.75), and 0.5 × 10(9) (IUI0.5) sperm cells/dose were evaluated. These factors were also evaluated using a range of farrowing rates (60%-90%), litter sizes (8-14 live-born pigs), and a selected semen collection frequency. The financial impact of the factors was assessed through simulation of a three-way crossbreeding system (maternal nucleus lines A and B and paternal nucleus line C) using ZPLAN. The highest return on investment (profit/cost) of boars was observed at 2.33 collections/wk (three periods of 24 hours between collections). Under this schedule, a significant (P profit. The highest gross return was obtained under S13 with IUI0.75 and IUI0.5. The net profit of S13 was 34.37% higher than the traditional S9 (P profit favored IUI0.5 with relative differences of 4.13%, 2.41%, 1.72%, and 0.43% compared to CAI3, CAI2, IUI1.5, and IUI0

  20. Mechanism-based screen for G1/S checkpoint activators identifies a selective activator of EIF2AK3/PERK signalling.

    Science.gov (United States)

    Stockwell, Simon R; Platt, Georgina; Barrie, S Elaine; Zoumpoulidou, Georgia; Te Poele, Robert H; Aherne, G Wynne; Wilson, Stuart C; Sheldrake, Peter; McDonald, Edward; Venet, Mathilde; Soudy, Christelle; Elustondo, Frédéric; Rigoreau, Laurent; Blagg, Julian; Workman, Paul; Garrett, Michelle D; Mittnacht, Sibylle

    2012-01-01

    Human cancers often contain genetic alterations that disable G1/S checkpoint control and loss of this checkpoint is thought to critically contribute to cancer generation by permitting inappropriate proliferation and distorting fate-driven cell cycle exit. The identification of cell permeable small molecules that activate the G1/S checkpoint may therefore represent a broadly applicable and clinically effective strategy for the treatment of cancer. Here we describe the identification of several novel small molecules that trigger G1/S checkpoint activation and characterise the mechanism of action for one, CCT020312, in detail. Transcriptional profiling by cDNA microarray combined with reverse genetics revealed phosphorylation of the eukaryotic initiation factor 2-alpha (EIF2A) through the eukaryotic translation initiation factor 2-alpha kinase 3 (EIF2AK3/PERK) as the mechanism of action of this compound. While EIF2AK3/PERK activation classically follows endoplasmic reticulum (ER) stress signalling that sets off a range of different cellular responses, CCT020312 does not trigger these other cellular responses but instead selectively elicits EIF2AK3/PERK signalling. Phosphorylation of EIF2A by EIF2A kinases is a known means to block protein translation and hence restriction point transit in G1, but further supports apoptosis in specific contexts. Significantly, EIF2AK3/PERK signalling has previously been linked to the resistance of cancer cells to multiple anticancer chemotherapeutic agents, including drugs that target the ubiquitin/proteasome pathway and taxanes. Consistent with such findings CCT020312 sensitizes cancer cells with defective taxane-induced EIF2A phosphorylation to paclitaxel treatment. Our work therefore identifies CCT020312 as a novel small molecule chemical tool for the selective activation of EIF2A-mediated translation control with utility for proof-of-concept applications in EIF2A-centered therapeutic approaches, and as a chemical starting point for

  1. Selection of dominant radionuclides for Phase 1 of the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.

    1991-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at Hanford since their inception in 1944. A vital step in the estimation of radiation doses is the determination of the source term,'' that is, the quantities of radionuclides that were released to the environment from the various Hanford operations. Hanford operations have at various times involved hundreds of different radionuclides, some in relatively large quantities. Those radionuclides present in the largest quantities, although significant from an operational handling point of view, may not necessarily have been those of greatest concern for offsite radiation dose. This report documents the selection of the dominant radionuclides (those that may have resulted in the largest portion of the received doses) in the source term for Phase 1 of the HEDR Project, that is, for atmospheric releases from 1944 through 1947 and for surface water releases from 1964 through 1966. 15 refs., 3 figs., 10 tabs.

  2. Wear behavior of 2-1/4 Cr-1Mo tubing against alloy 718 tube-support material in sodium-cooled steam generators

    International Nuclear Information System (INIS)

    Wilson, W.L.

    1983-05-01

    A series of prototypic steam generator 2-1/4 Cr-1 Mo tube/alloy 718 tube support plate wear tests were conducted in direct support of the Westinghouse Nuclear Components Division -- Breeder Reactor Components Project Large Scale steam Generator design. The initial objective was to verify the acceptable wear behavior of softer, ''over-aged'' alloy 718 support plate material. For all interfaces under all test conditions, resultant wear damage was adhesive in nature with varying amounts of 2-1/4 Cr-1 Mo tube material being adhesively transferred to the alloy 718 tube supports. Maximum tube wear depths exceeded the initially established design allowable limit of 127 μm (.005 in.) at 17 of the 18 interfaces tested. A decrease in contact stresses produced acceptable tube wear depths below a readjusted maximum design allowable value of 381 μm (.015 in.). Additional conservatisms associated with the simulation of a 40-year lifetime of rubbing in a one-week laboratory test provided further confidence that the 381 μm maximum tube wear allowance would not be exceeded in service. Softer, ''over-aged'' alloy 718 material was found to produce slightly less wear damage on 2-1/4 Cr-1 Mo tubing than fully age hardened material. Also, air formed oxide films on the alloy 718 reduced initial tube wear and delayed the onset of adhesive surface damage. However, at high surface stress levels, these films were not sufficiently stable to provide adequate long term protection from adhesive wear. The results of the present work and those of previous test programs suggest that the successful in-sodium tribological performance of 2-1/4 Cr-1 Mo/alloy 718 rubbing couples is dependent upon the presence of lubricative surface films, such as oxides and/or surface reaction or deposition products. 11 refs., 13 figs., 4 tabs

  3. Spectrum Band Selection in Delay-QoS Constrained Cognitive Radio Networks

    KAUST Repository

    Yang, Yuli

    2014-01-01

    In this paper, a cognitive radio (CR) network with multiple spectrum bands available for secondary users (SUs) is considered. For the SU\\'s active spectrum-band selection, two criteria are developed. One is to select the band with the highest secondary channel power gain, and the other is to select the band with the lowest interference channel power gain to primary users (PUs). With the quality-of-service (QoS) requirement concerning delay, the effective capacity (EC) behaviors over secondary links are investigated for both criteria under two spectrum-sharing constraints. To begin by presenting full benefits in these criteria, the constraint imposed on the secondary transmitter (ST) is the average interference limitation to PUs only. Furthermore, taking into account the ST\\'s battery/energy budget, the ST is imposed by joint constraints on its average interference to PUs, as well as on its own average transmit power. For either constraint, we formulate the ST\\'s optimal transmit power allocation to maximize the SU\\'s EC with both band-selection criteria and, correspondingly, obtain the secondary\\'s power allocation and maximum EC in closed forms. Numerical results demonstrated subsequently substantiate the validity of our derivations and provide a powerful tool for the spectrum-band selection in CR networks with multiple bands available. © 1967-2012 IEEE.

  4. Thermal expansion of Cr2xFe2-2xMo3O12, Al2xFe2-2xMo3O12 and Al2xCr2-2xMo3O12 solid solutions

    International Nuclear Information System (INIS)

    Ari, M.; Jardim, P.M.; Marinkovic, B.A.; Rizzo, F.; Ferreira, F.F.

    2008-01-01

    The transition temperature from monoclinic to orthorhombic and the thermal expansion of the orthorhombic phase were investigated for three systems of the family A 2 M 3 O 12 : Cr 2x Fe 2-2x Mo 3 O 12 , Al 2x Fe 2-2x Mo 3 O 12 and Al 2x Cr 2-2x Mo 3 O 12 . It was possible to obtain a single-phase solid solution in all studied samples (x=0, 0.1, 0.3, 0.5, 0.7, 0.9 and 1). A linear relationship between the transition temperature and the fraction of A 3+ cations (x) was observed for each system. In all orthorhombic solid solutions studied here the observed thermal expansion was anisotropic. These anisotropic thermal expansion properties of crystallographic axes a, b and c result in a low positive or near-zero overall linear coefficient of thermal expansion (α l =α V /3). The relationship between the size of A 3+ cations in A 2 M 3 O 12 and the coefficient of thermal expansion is discussed. Near-zero thermal expansion of Cr 2 Mo 3 O 12 is explained by the behavior of Cr-O and Mo-O bond distances, Cr-Mo non-bond distances and Cr-O-Mo bond angles with increasing temperature, estimated by Rietveld analysis of synchrotron X-ray powder diffraction data. - Graphical abstract: In this figure, all published overall linear coefficients of thermal expansion for orthorhombic A 2 M 3 O 12 family obtained through diffraction methods as a function of A 3+ cation radii size, together with dilatometric results, are plotted. Our results indicate that Cr 2 Mo 3 O 12 does not exactly follow the established relationship

  5. Biochemical and single-molecule analyses of the RNA silencing suppressing activity of CrPV-1A.

    Science.gov (United States)

    Watanabe, Mariko; Iwakawa, Hiro-Oki; Tadakuma, Hisashi; Tomari, Yukihide

    2017-10-13

    Viruses often encode viral silencing suppressors (VSSs) to counteract the hosts' RNA silencing activity. The cricket paralysis virus 1A protein (CrPV-1A) is a unique VSS that binds to a specific Argonaute protein (Ago)-the core of the RNA-induced silencing complex (RISC)-in insects to suppress its target cleavage reaction. However, the precise molecular mechanism of CrPV-1A action remains unclear. Here we utilized biochemical and single-molecule imaging approaches to analyze the effect of CrPV-1A during target recognition and cleavage by Drosophila Ago2-RISC. Our results suggest that CrPV-1A obstructs the initial target searching by Ago2-RISC via base pairing in the seed region. The combination of biochemistry and single-molecule imaging may help to pave the way for mechanistic understanding of VSSs with diverse functions. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Hot Corrosion Behavior of Bare, Cr3C2-(NiCr) and Cr3C2-(NiCr) + 0.2wt.%Zr Coated SuperNi 718 at 900 °C

    Science.gov (United States)

    Mudgal, Deepa; Singh, Surendra; Prakash, Satya

    2015-01-01

    Corrosion in incinerators, power plants, and chemical industries are frequently encountered due to the presence of salts containing sodium, sulphur, and chlorine. To obviate this problem, bare and coated alloys were tested under environments simulating the conditions present inside incinerators and power plants. 0.2 wt.% zirconium powder was incorporated in the Cr3C2-(NiCr) coating powder. The original powder and Zr containing powder was sprayed on Superni 718 alloy by D-gun technique. The bare and coated alloys were tested under Na2SO4 + K2SO4 + NaCl + KCl and Na2SO4 + NaCl environment. The corrosion rate of specimens was monitored using weight change measurements. Characterization of the corrosion products has been done using FE-SEM/EDS and XRD techniques. Bare and coated alloys showed very good corrosion resistance under given molten salt environments. Addition of 0.2wt.%Zr in Cr3C2-25%(NiCr) coating further greatly reduced the oxidation rate as well as improved the adherence of oxide scale to the coating surface during the time of corrosion.

  7. Molecular mapping of the Pinus monticola Cr2 gene using AFLP and SCAR markers

    Directory of Open Access Journals (Sweden)

    A.K.M. Ekramoddoullah

    2013-12-01

    Full Text Available White pine blister rust (WPBR, caused by Cronartium ribicola, is a devastating disease in five-needle pines. Genetic resistance is an important component of integrated strategies to control WPBR. The major resistance gene Cr2, discovered by Kinloch etal.(1999, is also effective against British Columbia (BC isolates of WPBR (Hunt et al. 2004. Pyramiding Cr2 gene with other resistancegenes is being pursued as a strategy in BC white pine breeding. To facilitate this strategy, we have recently identified a few RAPD markerslinked to Cr2 at one side (Liu et al. 2006. The objective of the present study was to identify amplified fragment length polymorphism(AFLP markers linked to both sides of Cr2 for its more precise apping. Use of the AFLP technique combined with bulked segregant analysis (BSA and haploid segregation analysis allowed the identification of five AFLP markers. Of these five AFLP markers in the Cr2 linkage, markers EacccMccgat-365, EactgMcccac- 290, and EacagEacag-750 werelinked in coupling and EacagMcccag-160r and EacccMccgat-180r in repulsion. Following cloning and sequencing of the AFLP andRAPD markers, specific PCR primers were designed and used in the amplification of sequence characterized amplified region(SCAR markers at both sides of Cr2. EacccMccgat- 365 and RAPD marker U570-843 reported previously were converted into SCARmarkers. These two SCARs segregated in a 1:1 (presence:absence ratio and the scoring cosegregated with their respective AFLP orRAPD marker. The SCAR marker EacccMccgat- 365-scar was positioned at 3.1 Kosambi cM from one side of Cr2 and U570-843-scarlocalized at 1.4 Kosambi cM from other side. Both SCAR markers can be useful in breeding programs with marker-assisted selection procedureto screen for resistance. This study represents the first report of the development of PCR-based sequence-specific markers linkedto blister rust resistance in five-needle pines. These findings may

  8. Cosmic ray LET spectra and doses on board Cosmos-2044 biosatellite

    International Nuclear Information System (INIS)

    Dudkin, V.E.; Kovalev, E.E.; Potapov, Yu.V.

    1992-01-01

    Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (∼ 20 g cm -2 shielding) and outside (1 g cm -2 ) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d -1 , respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d -1 . The effects of the flight parameters on the total fluence of, and on the dose from, the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of the CR flux is discussed. (author)

  9. Options for radiation dose optimisation in pelvic digital radiography: A phantom study

    International Nuclear Information System (INIS)

    Manning-Stanley, Anthony S.; Ward, Anthony J.; England, Andrew

    2012-01-01

    Purpose: To investigate the effects of phantom orientation and AEC chamber selection on radiation dose and image quality (IQ) for digital radiography (DR) examinations of the pelvis. Methods: A phantom study was conducted using a DR detector, utilising all AEC chamber combinations. Current recommended orientation (Cr-AEC) was with the outer AEC chambers cranially orientated. mAs (given), source-to-skin distance and kV p data facilitated entrance surface dose and effective dose calculations. Six anatomical areas were blindly graded by two observers (3-point scale) for IQ. Statistical differences in radiation dose were determined using the paired Student’s t-test. IQ data was analysed for inter-observer variability (ICC) and statistical differences (Wilcoxon test). Results: Switching phantom orientation (caudally orientated outer AEC chambers: Ca-AEC) reduced mean radiation dose by 36.8%, (p < 0.001). A minor reduction in median IQ (15.5 vs. 15) was seen (p < 0.001). One Ca-AEC orientated image (1.6%) had all anatomical areas graded ‘inadequate’ by at least one observer; all other images were considered ‘adequate’ for all areas. In the Ca-AEC orientation, at least a 44% dose reduction was achievable (p < 0.001) when only the outer AEC chambers were used. In the Cr-AEC orientation, at least 11% dose reduction was achieved (p < 0.001); here the central chamber was used alone, or in combination. IQ scores fell, but remained ‘adequate’. Conclusion: Switching pelvic orientation relative to AEC chamber position can optimise radiation dose during pelvic radiography. AEC chamber position should be clearly marked on equipment to facilitate this. AEC selection should be an active process.

  10. Enthalpy increment measurements of NaCrO2 using a high temperature Calvet calorimeter

    International Nuclear Information System (INIS)

    Iyer, V.S.; Jayanthi, K.; Ramarao, G.A.; Venugopal, V.; Sood, D.D.

    1991-01-01

    Enthalpy increment measurements on NaCrO 2 (s) were carried out in the temperature range 323 to 839 K using a high temperature Calvet micro calorimeter. The enthalpy increment values were least-squares fitted with temperature with the constraint that (Hdeg T - Hdeg 298 ) at 298.18 K equals zero, and can be given by: (Hdeg T - Hdeg 298 ) J/mol) ± 336 = -23515 + 75.364T(K) + 0.01256T 2 (K) (323 to 839 K). The first differential of the above equation with temperature gives the constant pressure molar heat capacity of NaCrO 2 (s), which is given by: Cdeg p (NaCrO 2 , s, T) (J/K mol) = 75.364 + 0.02512T(K). The thermal properties of NaCrO 2 (s) were calculated using the molar heat capacities from the present study and Sdeg(298 K) from the literature. (orig.)

  11. Magnetic properties of CuFe{sub 1−x}Cr{sub x}O{sub 2} nanoparticles surrounded by amorphous SiO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Mori, K.; Hachisu, M.; Yamazaki, T.; Ichiyanagi, Y., E-mail: yuko@ynu.ac.jp [Department of Physics, Graduate School of Engineering, Yokohama National University, Yokohama 240-8501 (Japan)

    2015-05-07

    CuFe{sub 1−x}Cr{sub x}O{sub 2} (0 ≤ x ≤ 1.0) nanoparticles surrounded by amorphous SiO{sub 2} with an average diameter of 30–50 nm were synthesized using a wet chemical method. The annealing temperatures were controlled to yield various sizes of single-phase CuFe{sub 1−x}Cr{sub x}O{sub 2} nanoparticles. CuFeO{sub 2} bulk crystal is known to have a multiferroic delafossite structure with two Néel temperatures of 11 and 14 K; however, the transition temperature shifted higher as the Cr–ion doping level increased. In addition, the lattice constants decreased in accordance with increased Cr-ion doping, which was confirmed by X-ray diffraction measurements. The magnetization curves showed weak ferromagnetic behavior and no coercivity was observed. Hence, frustration in the triangular lattice of the delafossite structure can be released by Cr–ion doping and higher magnetization can be expected. A fine structure analysis through X-ray absorption fine structure measurements was also conducted. It was found that the structure of the Cu ion is similar to that of Cu{sub 2}O, and the c axis of the CuFe{sub 1−x}Cr{sub x}O{sub 2} should be shortened by the Cr–ion doping.

  12. Hierarchical Cr{sub 2}O{sub 3}@OPC composites with octahedral shape for rechargeable nonaqueous lithium-oxygen batteries

    Energy Technology Data Exchange (ETDEWEB)

    Gan, Yongqing; Lai, Yanqing; Zhang, Zhian, E-mail: zhangzhian@csu.edu.cn; Chen, Wei; Du, Ke; Li, Jie

    2016-04-25

    The development of catalyst materials is the most significant issue that hinders the practical applications of Li-O{sub 2} batteries. Herein we show the design and synthesis of the hierarchical chromic oxide-octahedral porous carbon (Cr{sub 2}O{sub 3}@OPC) composites catalyst with octahedral shape that derived from Cr-based metal-organic frameworks (MIL-101(Cr)) precursor. When applied as cathode catalysts in rechargeable Li-O{sub 2} batteries, the electrode with Cr{sub 2}O{sub 3}@OPC composites catalyst exhibits a low charge and discharge over-potential, high discharge capacity and excellent cycling stability. What's more, the electrode with Cr{sub 2}O{sub 3}@OPC composite shows a discharge capacity up to ∼4800 mAh g{sub (catalyst} {sub +} {sub carbon)}{sup −1} at a current density of 0.1 mA cm{sup −2}, and exhibits a very stable discharge voltage plateau of 2.7 V and a charge voltage plateau of ∼3.9 V. With the addition of Cr{sub 2}O{sub 3}@OPC composite, the Li-O{sub 2} batteries can obtain good cycle performance over 50 cycles at a fixed capacity of 800 mAh g{sub (catalyst} {sub +} {sub carbon)}{sup −1}. These results indicating that the Cr{sub 2}O{sub 3}@OPC composite derived from MIL-101(Cr) would be a promising catalyst for Li-O{sub 2} batteries. - Highlights: • The Cr{sub 2}O{sub 3}@C composites were prepared by the pyrolysis of Cr-MIL-101. • The Cr{sub 2}O{sub 3}@C composites possess octahedral shape consisted of Cr{sub 2}O{sub 3}@C nanoparticle. • The Cr{sub 2}O{sub 3}@C composites have mesoporous structure with large specific area. • The Cr{sub 2}O{sub 3}@C composites have an excellent intrinsic electrocatalytic activity. • The Cr{sub 2}O{sub 3}@C electrode exhibits great cycling performance.

  13. Development of Cr3C2-25(Ni20Cr) nanostructured coatings

    International Nuclear Information System (INIS)

    Cunha, Cecilio Alvares da

    2012-01-01

    This study is divided in two parts. The first part is about the preparation of nanostructured Cr 3 C 2 -25(Ni20Cr) powders by high energy milling followed by characterization of the milled and the as received powder. Analyses of some of the data obtained were done using a theoretical approach. The second part of this study is about the preparation and characterization of coatings prepared with the nanostructured as well as the as received Cr 3 C 2 -25(Ni20Cr) powders. The high temperature erosion-oxidation (E-O) behavior of the coatings prepared with the two types of powders has been compared based on a technological approach. The average crystallite size of the Cr 3 C 2 -25(Ni20Cr) powder decreased rapidly from 145 nm to 50 nm in the initial stages of milling and thereafter decreased slowly to a steady state value of around 10 nm with further increase in milling time. This steady state corresponds to the beginning of a dynamic recovery process. The maximum lattice strain (ε = 1,17%) was observed in powders milled for 16 hours, and this powders critical crystallite size was 28 nm. In contrast, the lattice parameter attained a minimum for powders milled for 16 hours. Upon reaching the critical crystallite size, the dislocation density attained a steady state regime and all plastic deformation introduced in the material there after was in the form of events occurring at the grain boundaries, due mainly to grain boundary sliding. The deformation energy stored in the crystal lattice of the Cr 3 C 2 -25(Ni20Cr) powders milled for different times was determined from enthalpy variation measurements. These results indicated that the maximum enthalpy variation (δH = 722 mcal) also occurred for powders milled for 16 hours. In a similar manner, the maximum specific heat variation (δC p = 0,278 cal/gK) occurred for powders milled for 16 hours. The following mechanical properties of Cr 3 C 2 -25(Ni20Cr) coatings prepared using the HVOF thermal spray process were determined

  14. MgO–CaO–Cr2O3 composition as a novel refractory brick: Use of Cr2O3 nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Ghasemi-Kahrizsangi, S.; Dehsheikh, H.G.; Boroujerdnia, M.

    2017-07-01

    At this study the effect of Cr2O3 nanoparticles (up to 3wt.%) on the physical and mechanical properties of MgO–CaO refractory composition with emphasis on the hydration resistance improvement have been investigated. Specimens pressed at 90MPa then were sintered at 1650°C for 5h in an electric furnace. Properties such as bulk density, apparent porosity, cold crushing strength and hydration resistance were examined. The crystalline phases and microstructure characteristics of sintered specimens were studied by X-ray diffraction (XRD) and scanning electron microscopy (SEM/EDS), respectively. Results shown that add of the 1.5wt.% Cr2O3 nanoparticles have the best results i.e. increased the bulk density (3.41g/cm3), cold crushing strength (848kg/cm2), hydration resistance (1.5%) and decreased apparent porosity (5.58%), respectively. The mechanism of specimens hydration resistance improvement are: (i) decreasing the amount of free CaO and MgO with converted to high hydration resistance phases such as CaCr2O4 and MgCr2O4 phases, (ii) promotion of the densification as well as (iii) modification of the microstructure. (Author)

  15. Hot corrosion of Co-Cr, Co-Cr-Al, and Ni-Cr alloys in the temperature range of 700-750 deg C

    Science.gov (United States)

    Chiang, K. T.; Meier, G. H.

    1980-01-01

    The effect of SO3 pressure in the gas phase on the Na2SO4 induced hot corrosion of Co-Cr, Ni-Cr, and Co-Cr-Al alloys was studied in the temperature range 700 to 750 C. The degradation of the Co-Cr and Ni-Cr alloys was found to be associated with the formation of liquid mixed sulfates (CoSO4-Na2SO4 or NiSO4-Na2SO4) which provided a selective dissolution of the Co or Ni and a subsequent sulfidation oxidation mode of attack which prevented the maintenance of a protective Cr2O3 film. A clear mechanism was not developed for the degradation of Co-Cr-Al alloys. A pitting corrosion morphology was induced by a number of different mechanisms.

  16. Selective sampling and measurement of Cr (VI) in water with polyquaternary ammonium salt as a binding agent in diffusive gradients in thin-films technique.

    Science.gov (United States)

    Chen, Hong; Zhang, Yang-Yang; Zhong, Ke-Li; Guo, Lian-Wen; Gu, Jia-Li; Bo, Le; Zhang, Meng-Han; Li, Jian-Rong

    2014-04-30

    A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3-12 and ionic strength from 1 × 10(-3) to 1 molL(-1). DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively. Compared with diphenylcarbazide spectrophotometric method (DPC), the measurement of Cr (VI) with PQAS DGT was agreement with that of DPC method in the industrial wastewater. PQAS-DGT device had been successfully deployed in local freshwater. The concentrations of Cr (VI) determined by PQAS DGT coupled with GFAAS in Nuer River, Ling River and North Lake were 0.73 ± 0.09 μg L(-1), 0.50 ± 0.07 μg L(-1) and 0.61 ± 0.07 μg L(-1), respectively. The results indicate that PQAS DGT device can be used for the selective sampling and measurement Cr (VI) in water and its detection limit is lower than that of DPC method. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Near-infrared spectrophotometry of eight 3CR radiogalaxies: the first detections of [O III]500.7 and [S III]953.2 emission lines in galaxies with z > 1

    International Nuclear Information System (INIS)

    Rawlings, Steve; Lacy, Mark

    1991-01-01

    We present the results of near-IR spectrophotometry of eight 3CR radiogalaxies with redshifts in the range 0.256≤z≤1.575. The narrow [O III]500.7 emission line was detected in 3C13 (z = 1.351), and the narrow [S III]953.2 emission line in 3C79 (z = 0.256), in the northern near-IR knot of 3C356 (z = 1.079) and marginally in 3C368 (z=1.132). We show that narrow-line emission can sometimes account for a substantial fraction of the broad-band near-IR flux arising from the substructures of high-z radiogalaxies, but that this fraction is strongly dependent on, and therefore a valuable probe of, physical conditions within the substructures. (author)

  18. Cell- and stage-specific chromatin structure across the Complement receptor 2 (CR2/CD21) promoter coincide with CBF1 and C/EBP-beta binding in B cells.

    Science.gov (United States)

    Cruickshank, Mark N; Fenwick, Emily; Karimi, Mahdad; Abraham, Lawrence J; Ulgiati, Daniela

    2009-08-01

    Stringent developmental transcription requires multiple transcription factor (TF) binding sites, cell-specific expression of signaling molecules, TFs and co-regulators and appropriate chromatin structure. During B-lymphopoiesis, human Complement receptor 2 (CR2/CD21) is detected on immature and mature B cells but not on B cell precursors and plasma cells. We examined cell- and stage-specific human CR2 gene regulation using cell lines modeling B-lymphopoiesis. Chromatin accessibility assays revealed a region between -409 and -262 with enhanced accessibility in mature B cells and pre-B cells, compared to either non-lymphoid or plasma cell-types, however, accessibility near the transcription start site (TSS) was elevated only in CR2-expressing B cells. A correlation between histone acetylation and CR2 expression was observed, while histone H3K4 dimethylation was enriched near the TSS in both CR2-expressing B cells and non-expressing pre-B cells. Candidate sites within the CR2 promoter were identified which could regulate chromatin, including a matrix attachment region associated with CDP, SATB1/BRIGHT and CEBP-beta sites as well as two CBF1 sites. ChIP assays verified that both CBF1 and C/EBP-beta bind the CR2 promoter in B cells raising the possibility that these factors facilitate or respond to alterations in chromatin structure to control the timing and/or level of CR2 transcription.

  19. Microstructure and Properties of Plasma-Sprayed Mixture of Cr2O3 and TiO2

    Czech Academy of Sciences Publication Activity Database

    Ctibor, Pavel; Píš, I.; Kotlan, J.; Pala, Zdeněk; Štengl, Václav; Homola, P.

    2013-01-01

    Roč. 22, č. 7 (2013), s. 1163-1169 ISSN 1059-9630 Institutional support: RVO:61389021 ; RVO:61388980 Keywords : bandgap * Cr2O3 * photocatalysis * resistivity * spectroscopy * TiO2 Subject RIV: BL - Plasma and Gas Discharge Physics; CA - Inorganic Chemistry (UACH-T) Impact factor: 1.491, year: 2013 http://link.springer.com/article/10.1007%2Fs11666-013-9969-9

  20. Gas Sensing Properties of Pure and Cr Activated WO3 Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    V. B. GAIKWAD

    2010-09-01

    Full Text Available Thick films of WO3 (Tungsten Oxide were prepared by screen-printing techniques. The surfaces of the films were modified by dipping them into an aqueous solution of Chromium Oxide (CrO3 for different intervals of time, followed by firing at 550 oC for 30 min. The gas sensing performance of the pure and Cr2O3-modified films was tested for various gases at different temperatures. The unmodified films showed response to H2S, ethanol and cigar smoke. However Cr2O3- modified films suppresses gas sensing response to all gases except H2S. The surface modification, using dipping process, altered the adsorbate-adsorbent interactions, which gave the specific selectivity and enhanced sensitivity to H2S gas. The gas response, selectivity, thermal stability and recovery time of the sensor were measured and presented. The role played by surface chromium species to improve gas sensing performance is discussed.

  1. Study on the metabolism of physiological amounts of Cr(III) intragastrical administration in normal rats using activable enriched stable isotope Cr-50 compound as a tracer

    International Nuclear Information System (INIS)

    Feng, W.Y.; Ding, W.J.; Qian, Q.F.; Chai, Z.F.

    1998-01-01

    In order to study the metabolism of physiological amounts of 51 Cr (10μg/100 g of body wt.) intragastrically administered in rats, the activable enriched stable isotope Cr-50 compound Cr 2 O 3 was used as a tracer. The absorption and distribution of 51 Cr(III) in rats with time were studied. Significant 51 Cr contents were found in all the organs and tissues of interest. The kidney, liver and bone contain higher amounts of 51 Cr than others. The fact that specific activities of 51 Cr are notably high in kidney, bone, spleen and pancreas and decrease gradually with time suggests that there are tighter binding of chromium in these organs. The excretion of 51 Cr at various time intervals was also studied. Almost totally intragastrically administered dose was excreted in the feces. The increased urinary excretion of 51 Cr with time indicates that the urine-chromium is the metabolic derivative of organism. In view of the tissues distribution and excretion, it can be concluded that no more than 1% of the dose was absorbed from the gastrointestinal tract. (author)

  2. Selective removal of Cr(VI) from aqueous solution by polypyrrole/2,5-diaminobenzene sulfonic acid composite

    CSIR Research Space (South Africa)

    Kera, Nazia H

    2016-08-01

    Full Text Available and morphology of the composite were investigated by ATR-FTIR, FE-SEM, EDX, TGA, XRD and XPS studies. The adsorption of Cr(VI) by PPy/DABSA composite was highly pH dependent and optimum removal was achieved at pH 2. Adsorption of Cr(VI) was confirmed by EDX...

  3. Successful Outcome of Low-Dose S-1 Used to Treat Buccal Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Kazuyuki Yusa

    2017-01-01

    Full Text Available This case report describes an 86-year-old woman with dormant right buccal squamous cell carcinoma who was able to maintain a reasonable quality of life after being treated with oral low-dose S-1 (80 mg/day. The treatment regimen started in April 2014 and consisted of two weeks of S-1 followed by a one-week interval. The patient remains on this regimen while maintaining her quality of life and she has been under follow-up as an outpatient for 36 months. The outcomes for this patient indicated that low-dose S-1 is a valid anticancer therapy that may help maintain quality of life for some patients with incurable or dormant cancers.

  4. AEC testing in a CR environment

    International Nuclear Information System (INIS)

    McLeod, R.

    2004-01-01

    Full text: Testing of x-ray machine automatic exposure control (AEC) functionality for varying kVp and patient thickness is a fundamental health physics check. Current test protocols tend to be based on testing in a film environment using film optical density as the measure of conformance. With the move into the digital x-ray image age with the use of computed radiography (CR) and digital radiography (DR) equipment and its associated image storage and retrieval system (PACS) a new AEC testing protocol is required. All CR systems provide a dose assessment tool (called Exposure Index or EI by Kodak) that could be used as a surrogate for optical density. However this work aims to derive an efficient means of assessing the functioning of the AEC of x-ray machines in a CR environment using dose measurement alone. This would eliminate the need to process the many image plates normally required for AEC testing in order to obtain and analyse the exposure measure from the CR system. The EI, and other brand's equivalents, is calibrated for a given condition (for Kodak 80kVp 0.5mmCu + 1mmAl). In order to use dose measurement alone the relationship between EI and dose must be known for varying kVp and patient thicknesses (represented by a perspex phantom). This will depend on the response of the CR plate to varying beam energies. This was assessed using a series of paired exposures at various kVp and perspex thicknesses. In the first exposure of each pair a Kodak CR plate was used, processed in the normal way, and the EI noted. In a second identical exposure an Innovision 35050A pancake ionization chamber was placed in the bucky tray within a specially modified film cassette and the dose measured. Over the 50-125kVp range of clinical use the kV response of the Kodak PSP's shown below is essentially flat for a set dose to the image plate and filtered using the standard Kodak method of 0.5mmCu + 1mmAl. Similar data will be presented showing this relationship using a perspex

  5. Electrochemical probings of Li1+xVS2

    International Nuclear Information System (INIS)

    Gupta, Asha; Mullins, C. Buddie; Goodenough, John B.

    2012-01-01

    Re-investigation of Li insertion into the layers of Li 1+x V 1−y M y S 2 (M = Cr, Ni and y = 0 and 0.1, x ≤ 0.8) reveals that the transformation of Li from octahedral to tetrahedral sites in Li 1+x VS 2 leads to a 1.0 V stabilization V(III)/V(II) plateau at 0.1C rate. Substitution of 10 mol% Ni for V to form Li 1+x V 0.9 Ni 0.1 S 2 increases the voltage on Li insertion by 0.1–0.2 V compared to nominal LiVS 2 , but it leads to an overall decrease in the capacity. An irreversible capacity loss on the initial charge/discharge cycle is the result of formation of an SEI layer at and below 1 V versus lithium. 10 mol% substitution of Cr for V (i.e. Li 1+x V 0.9 Cr 0.1 S 2 ) has no effect on the voltage, but it increases the capacity fade as the discharge/charge cycles progress.

  6. Efeito do citrato e taurina em meio CR2aa no desenvolvimento de embriões bovinos fecundados in vitro Effect of citrate and taurine added to CR2aa medium on the development of in vitro-fertilized bovine embryos

    Directory of Open Access Journals (Sweden)

    L.S.A. Camargo

    2009-02-01

    Full Text Available Avaliou-se o efeito do citrato em meio CR2aa suplementado com soro fetal bovino (SFB ou livre de proteínas séricas e sua associação com taurina no desenvolvimento de embriões bovinos fecundados in vitro. Embriões foram cultivados em CR2aa contendo 0, 0,5, 1,0 e 3,0mM citrato, suplementado com 10% SFB (experimento 1 ou com álcool polivinil (PVA; experimento 2. No terceiro experimento, embriões foram cultivados em meio com 0,5mM citrato, ou 7mM taurina, ou com a associação de ambos, suplementado com SFB. Os cultivos foram realizados com células do cumulus em ambiente a 38,8ºC com 5% de CO2 em ar atmosférico. Melhora no desenvolvimento embrionário foi observado no cultivo de embriões em CR2aa com 0,5 e 1,0mM citrato na ausência de SFB (P0,05 a produção de embriões ou o número de células. Citrato em meio CR2aa pode ser uma alternativa para cultivo embrionário em condições atmosféricas com 5% de CO2 em ar na ausência de proteína sérica.The effect of citrate added to CR2aa medium supplemented with fetal calf serum (FCS or serum-proteinfree and its association with taurine on the development of in vitro-fertilized bovine embryos was evaluated. Embryos were cultured with 0, 0.5, 1.0, and 3.0mM citrate, in CR2aa supplemented with 10% FCS (experiment 1, or polyvinyl alcohol (PVA; experiment 2. In experiment 3, embryos were cultured with 0.5mM citrate, 7.0mM taurine or with association of both, in medium supplemented with FCS. Embryo culture was performed with cumulus cells at 38.8ºC in 5% CO2 under air for all experiments. Positive effect on embryo development was only observed with 0.5 and 1.0mM citrate in FCS-free CR2aa (P0.05 embryo rate nor total cell number. Citrate in CR2aa medium can be an alternative for serumfree embryo culture under 5% CO2 in air, absence of serum protein.

  7. Structural and magnetic properties of (Co1-xNix)Cr2O4 (x = 0.5, 0.25) nanoparticles

    Science.gov (United States)

    Mohanty, P.; Prinsloo, A. R. E.; Doyle, B. P.; Carleschi, E.; Sheppard, C. J.

    2018-05-01

    Nanoparticles of (Co1-xNix)Cr2O4, with x = 0.5 and 0.25, were prepared utilizing the sol-gel technique, in order to investigate the effect of Ni substitution at the Co site. The crystal structure of the prepared samples was identified using X-ray diffraction. Transmission electron microscopy images indicate a non-uniform distribution in particle sizes. Temperature dependent magnetization measurements as a function of probing field demonstrate different magnetic transition temperatures to that of both the parent compounds. The magnetization as a function of applied magnetic field shows a wasp-waist like feature for (Co0.5Ni0.5)Cr2O4 nanoparticles measured at 10 K, which is absent in both NiCr2O4 and CoCr2O4. This feature diminished for other measurement temperatures below the Curie temperature and was also absent at all temperatures for the (Co0.75Ni0.25)Cr2O4 nanoparticles. X-ray photoemission spectroscopy results show that the Ni cations prefers the 3+ and Co the 2+ oxidation states, while that of Cr was found to be 3+. However, mixed oxidation states were observed for Ni and Co in both samples, which can influence the magnetic properties.

  8. TLR4-dependent internalization of CX3CR1 aggravates sepsis-induced immunoparalysis.

    Science.gov (United States)

    Ge, Xin-Yu; Fang, Shang-Ping; Zhou, Miao; Luo, Jing; Wei, Juan; Wen, Xue-Ping; Yan, Xiao-Di; Zou, Zui

    2016-01-01

    Sepsis, the most severe manifestation of infection, poses a major challenge to health-care systems around the world. Limited ability to clean and remove the pathogen renders difficulty in septic patients to recover from the phase of immunoparalysis. The present study found the vital role of CX3CR1 internalization on sepsis-induced immunoparalysis. A mouse model with cecal ligation and puncture (CLP) and cell model with lipopolysaccharides (LPS) were employed to explore the relationship between CX3CR1 internalization and septic immunoparalysis. Immunoparalysis model in mice was established 4 days after CLP with significantly decreased proinflammatory cytokines. Flow cytometry analysis found a decreased surface expression of CX3CR1 during immunoparalysis, which was associated with reduced mRNA level and increased internalization of CX3CR1. G-protein coupled receptor kinase 2 (GRK2) and β-arrestin2 were significantly increased during septic immunoparalysis and involved in the internalization of CX3CR1. TLR4 -/- or TLR4 inhibitor-treated macrophages exhibited an inhibited expression of GRK2 and β-arrestin2, along with reduced internalization of CX3CR1. Moreover, the knockdown of GRK2 and β-arrestin2 inhibited the internalization of CX3CR1 and led to a higher response on the second hit, which was associated with an increased activation of NF-κB. The critical association between internalization of CX3CR1 and immunosuppression in sepsis may provide a novel reference for clinical therapeutics.

  9. Pharmacokinetic/Pharmacodynamic Modelling of Receptor Internalization with CRTH2 Antagonists to Optimize Dose Selection.

    Science.gov (United States)

    Krause, Andreas; Zisowsky, Jochen; Strasser, Daniel S; Gehin, Martine; Sidharta, Patricia N; Groenen, Peter M A; Dingemanse, Jasper

    2016-07-01

    The chemoattractant receptor-homologous molecule expressed on T helper-2 cells (CRTH2) is a G-protein-coupled receptor for prostaglandin D2 (PGD2), a key mediator in inflammatory disorders. Two selective and potent CRTH2 antagonists currently in clinical development, ACT-453859 and setipiprant, were compared with respect to their (predicted) clinical efficacy. Population pharmacokinetic (PK) and pharmacodynamic (PD) models were developed to characterize how plasma concentrations (PK) of ACT-453859, its active metabolite ACT-463036 and setipiprant related to their effect on blocking PGD2-induced internalization of CRTH2 on eosinophils (PD). Simulations were used to identify doses and dosing regimens leading to 90 % of maximum blockade of CRTH2 internalization at trough. A combined concentration of ACT-453859 and its metabolite ACT-463036, with weights proportional to potency (based on an eosinophil shape change assay), enabled good characterization of the PD effect. The modelling and simulation results facilitated decision making by suggesting an ACT-453859 dose of 400 mg once daily (or 100 mg twice daily) for clinically relevant CRTH2 antagonism. Pharmacometric quantification demonstrated that CRTH2 internalization is a useful new biomarker to study CRTH2 antagonism. Ninety percent of maximum blockade of CRTH2 internalization at trough is suggested as a quantitative PD target in clinical studies.

  10. Cu{sup 2+}, Co{sup 2+} and Cr{sup 3+} doping of a calcium phosphate cement influences materials properties and response of human mesenchymal stromal cells

    Energy Technology Data Exchange (ETDEWEB)

    Schamel, Martha [Department for Functional Materials in Medicine and Dentistry, University of Würzburg, Pleicherwall 2, 97070 Würzburg (Germany); Bernhardt, Anne; Quade, Mandy; Würkner, Claudia [Centre for Translational Bone, Joint and Soft Tissue Research, University Hospital Carl Gustav Carus and Faculty of Medicine of Technische Universität Dresden, Fetscherstraße 74, 01307 Dresden (Germany); Gbureck, Uwe; Moseke, Claus [Department for Functional Materials in Medicine and Dentistry, University of Würzburg, Pleicherwall 2, 97070 Würzburg (Germany); Gelinsky, Michael [Centre for Translational Bone, Joint and Soft Tissue Research, University Hospital Carl Gustav Carus and Faculty of Medicine of Technische Universität Dresden, Fetscherstraße 74, 01307 Dresden (Germany); Lode, Anja, E-mail: anja.lode@tu-dresden.de [Centre for Translational Bone, Joint and Soft Tissue Research, University Hospital Carl Gustav Carus and Faculty of Medicine of Technische Universität Dresden, Fetscherstraße 74, 01307 Dresden (Germany)

    2017-04-01

    The application of biologically active metal ions to stimulate cellular reactions is a promising strategy to accelerate bone defect healing. Brushite-forming calcium phosphate cements were modified with low doses of Cu{sup 2+}, Co{sup 2+} and Cr{sup 3+}. The modified cements released the metal ions in vitro in concentrations which were shown to be non-toxic for cells. The release kinetics correlated with the solubility of the respective metal phosphates: 17–45 wt.-% of Co{sup 2+} and Cu{sup 2+}, but < 1 wt.-% of Cr{sup 3+} were released within 28 days. Moreover, metal ion doping led to alterations in the exchange of calcium and phosphate ions with cell culture medium. In case of cements modified with 50 mmol Cr{sup 3+}/mol β-tricalcium phosphate (β-TCP), XRD and SEM analyses revealed a significant amount of monetite and a changed morphology of the cement matrix. Cell culture experiments with human mesenchymal stromal cells indicated that the observed cell response is not only influenced by the released metal ions but also by changed cement properties. A positive effect of modifications with 50 mmol Cr{sup 3+} or 10 mmol Cu{sup 2+} per mol β-TCP on cell behaviour was observed in indirect and direct culture. Modification with Co{sup 2+} resulted in a clear suppression of cell proliferation and osteogenic differentiation. In conclusion, metal ion doping of the cement influences cellular activities in addition to the effect of released metal ions by changing properties of the ceramic matrix. - Highlights: • A brushite-forming calcium phosphate cement was modified by doping with bioactive Cu{sup 2+}, Co{sup 2+} and Cr{sup 3+} ions. • The metal ions were integrated in the cement matrix, setting was not affected. • The modified cements released the metal ions in doses non-toxic for cells. • Modification with Cr{sup 3+} ions enhanced the biocompatibility of the cement.

  11. Selective sampling and measurement of Cr (VI) in water with polyquaternary ammonium salt as a binding agent in diffusive gradients in thin-films technique

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hong, E-mail: redastar@163.com [College of Chemistry, Chemical Engineering and Food Safety, Bohai University (China); Research Institute of Food Science, Bohai University (China); Food Safety Key Lab of Liaoning Province, Jinzhou 121013 (China); Zhang, Yang-Yang; Zhong, Ke-Li; Guo, Lian-Wen [College of Chemistry, Chemical Engineering and Food Safety, Bohai University (China); Research Institute of Food Science, Bohai University (China); Food Safety Key Lab of Liaoning Province, Jinzhou 121013 (China); Gu, Jia-Li [College of Chemistry, Chemical Engineering and Food Safety, Bohai University (China); Bo, Le; Zhang, Meng-Han [College of Chemistry, Chemical Engineering and Food Safety, Bohai University (China); Research Institute of Food Science, Bohai University (China); Food Safety Key Lab of Liaoning Province, Jinzhou 121013 (China); Li, Jian-Rong, E-mail: lijianrong@zjgsu.edu.cn [College of Chemistry, Chemical Engineering and Food Safety, Bohai University (China); Research Institute of Food Science, Bohai University (China); Food Safety Key Lab of Liaoning Province, Jinzhou 121013 (China)

    2014-04-01

    Graphical abstract: - Highlights: • We develop a new DGT device for in situ sampling Cr (VI) in water. • Polyquaternary ammonium salt (PQAS) was used as binding agent of DGT device. • Cr (VI) can be accumulated in the PQAS binding phase whereas Cr (III) cannot. • The DGT performance was independent of pH 3–12 and ionic strength 1 × 10{sup −3}–1 mol L{sup −1}. - Abstract: A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3–12 and ionic strength from 1 × 10{sup −3} to 1 mol L{sup −1}. DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively. Compared with diphenylcarbazide spectrophotometric method (DPC), the measurement of Cr (VI) with PQAS DGT was agreement with that of DPC method in the industrial wastewater. PQAS-DGT device had been successfully deployed in local freshwater. The concentrations of Cr (VI) determined by PQAS DGT coupled with GFAAS in Nuer River, Ling River and North Lake were 0.73 ± 0.09 μg L{sup −1}, 0.50 ± 0.07 μg L{sup −1} and 0.61 ± 0.07 μg L{sup −1}, respectively. The results indicate that PQAS DGT device can be used for the selective sampling and measurement Cr (VI) in water and its detection limit is lower than that of DPC method.

  12. Selective sampling and measurement of Cr (VI) in water with polyquaternary ammonium salt as a binding agent in diffusive gradients in thin-films technique

    International Nuclear Information System (INIS)

    Chen, Hong; Zhang, Yang-Yang; Zhong, Ke-Li; Guo, Lian-Wen; Gu, Jia-Li; Bo, Le; Zhang, Meng-Han; Li, Jian-Rong

    2014-01-01

    Graphical abstract: - Highlights: • We develop a new DGT device for in situ sampling Cr (VI) in water. • Polyquaternary ammonium salt (PQAS) was used as binding agent of DGT device. • Cr (VI) can be accumulated in the PQAS binding phase whereas Cr (III) cannot. • The DGT performance was independent of pH 3–12 and ionic strength 1 × 10 −3 –1 mol L −1 . - Abstract: A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3–12 and ionic strength from 1 × 10 −3 to 1 mol L −1 . DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively. Compared with diphenylcarbazide spectrophotometric method (DPC), the measurement of Cr (VI) with PQAS DGT was agreement with that of DPC method in the industrial wastewater. PQAS-DGT device had been successfully deployed in local freshwater. The concentrations of Cr (VI) determined by PQAS DGT coupled with GFAAS in Nuer River, Ling River and North Lake were 0.73 ± 0.09 μg L −1 , 0.50 ± 0.07 μg L −1 and 0.61 ± 0.07 μg L −1 , respectively. The results indicate that PQAS DGT device can be used for the selective sampling and measurement Cr (VI) in water and its detection limit is lower than that of DPC method

  13. (51Cr)EDTA intestinal permeability in children with cow's milk intolerance

    Energy Technology Data Exchange (ETDEWEB)

    Schrander, J.J.; Unsalan-Hooyen, R.W.; Forget, P.P.; Jansen, J. (Academic Hospital Maastricht (Netherlands))

    1990-02-01

    Making use of ({sup 51}Cr)EDTA as a permeability marker, we measured intestinal permeability in a group of 20 children with proven cow's milk intolerance (CMI), a group of 17 children with similar complaints where CMI was excluded (sick controls), and a group of 12 control children. ({sup 51}Cr)EDTA test results (mean +/- SD) were 6.85 +/- 3.64%, 3.42 +/- 0.94%, and 2.61 +/- 0.67% in the group with CMI, the sick control, and the control group, respectively. When compared to both control groups, patients with cow's milk intolerance (CMI) showed a significantly increased small bowel permeability. We conclude that the ({sup 51}Cr)EDTA test can be helpful for the diagnosis of cow's milk intolerance.

  14. Fast Neutron Dosimetry Using CR-39 Nuclear Track Detector

    International Nuclear Information System (INIS)

    ZAKI, M.; ABDEL-NABY, A.; MORSY, A.

    2010-01-01

    Measurement of the neutron dose in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In the present study, a method for the measurement of neutron dose using the UV-Vis spectra of CR-39 plastic track detector was investigated. A set of CR-39 plastic detectors was exposed to 252 Cf neutron source, which had the yield of 0.68x10 8 /s, and neutron dose equivalent rate 1m apart from the source is equal to 3.8 mrem/h. The samples were etched for 10 h in 6.25 N NaOH at 70 o C. The absorbance of the etched samples was measured using UV-visible spectrophotometer as a function of neutron dose. It was observed that there was a linear relationship between the optical absorption of these detectors and neutron dose. This means that the exposure dose of neutron can be determined by knowing the optical absorption of the sample. These results were compared with previous study. It was found that there was a matching and good agreement with their investigations.

  15. Elevated-temperature tensile properties of 2 1/4 Cr-1 Mo steel irradiated in the EBR-II, AD-2 experiment

    International Nuclear Information System (INIS)

    Klueh, R.L.; Vitek, J.M.

    1984-01-01

    The effect of irradiated on the tensile properties of 2 1/4 Cr-1 Mo steel was determined for specimens irradiation in EBR-II at 390 to 550 0 C. Unirradiated control specimens and specimens aged for 5000 h at the irradiation temperatures were also tested. Irradiation to approximately 9 dpa at 390 0 C increased the strength and decreased the ductility compared with the unirradiated and aged specimens. Softening occurred in samples irradiated and tested at 450, 500, and 550 0 C

  16. Modifications in the optical and thermal properties of a CR-39 polymeric detector induced by high doses of γ-radiation

    Science.gov (United States)

    Saad, A. F.; Ibraheim, Mona H.; Nwara, Aya M.; Kandil, S. A.

    2018-04-01

    Effects of γ-radiation on the optical and thermal properties of a poly allyl diglycol carbonate (PADC), a form of CR-39, polymer have been investigated. CR-39 detectors were exposed to γ-rays at very high doses ranging from 5.0 × 105 to 3.0 × 106 Gy. The induced changes were analyzed using ultraviolet-visible spectroscopy (UV-VIS) in absorbance mode, and thermogravimetric analysis (TGA). The UV-visible spectra of the virgin and γ-irradiated CR-39 polymer detectors displayed a significant decreasing trend in their optical energy band gaps for indirect transitions, whereas for the direct ones showed a little change. This drop in the energy band gap with increasing dose is discussed on the basis of the gamma irradiation induced modifications in the CR-39 polymeric detector. The TGA thermograms show that the weight loss rate increased with increase in dose, which may be due to the disordered system via scission followed by crosslinking in the irradiated polymer detector. The TGA thermograms also indicated that the CR-39 detector decomposed in three/four stages for the virgin and irradiated samples. The activation energy for thermal decomposition was determined using a type of Arrhenius equation based on the TGA experimental results. These experimental results so obtained can be well used in radiation dosimetry.

  17. 53Cr NMR study of CuCrO2 multiferroic

    Science.gov (United States)

    Smol'nikov, A. G.; Ogloblichev, V. V.; Verkhovskii, S. V.; Mikhalev, K. N.; Yakubovskii, A. Yu.; Kumagai, K.; Furukawa, Y.; Sadykov, A. F.; Piskunov, Yu. V.; Gerashchenko, A. P.; Barilo, S. N.; Shiryaev, S. V.

    2015-11-01

    The magnetically ordered phase of the CuCrO2 single crystal has been studied by the nuclear magnetic resonance (NMR) method on 53Cr nuclei in the absence of an external magnetic field. The 53Cr NMR spectrum is observed in the frequency range νres = 61-66 MHz. The shape of the spectrum depends on the delay tdel between pulses in the pulse sequence τπ/2- t del-τπ- t del-echo. The spin-spin and spin-lattice relaxation times have been measured. Components of the electric field gradient, hyperfine fields, and the magnetic moment on chromium atoms have been estimated.

  18. Systematic overview of preoperative (neoadjuvant) chemoradiotherapy trials in oesophageal cancer: Evidence of a radiation and chemotherapy dose response

    International Nuclear Information System (INIS)

    Geh, J. Ian; Bond, Simon J.; Bentzen, Soren M.; Glynne-Jones, Robert

    2006-01-01

    Background and purpose: Numerous trials have shown that pathological complete response (pCR) following preoperative chemoradiotherapy (CRT) and surgery for oesophageal cancer is associated with improved survival. However, different radiotherapy doses and fractionations and chemotherapy drugs, doses and scheduling were used, which may account for the differences in observed pCR and survival rates. A dose-response relationship may exist between radiotherapy and chemotherapy dose and pCR. Patients and methods: Trials using a single radiotherapy and chemotherapy regimen (5FU, cisplatin or mitomycin C-based) and providing information on patient numbers, age, resection and pCR rates were eligible. The endpoint used was pCR and the covariates analysed were prescribed radiotherapy dose, radiotherapy dosexdose per fraction, radiotherapy treatment time, prescribed chemotherapy (5FU, cisplatin and mitomycin C) dose and median age of patients within the trial. The model used was a multivariate logistic regression. Results: Twenty-six trials were included (1335 patients) in which 311 patients (24%) achieved pCR. The probability of pCR improved with increasing dose of radiotherapy (P=0.006), 5FU (P=0.003) and cisplatin (P=0.018). Increasing radiotherapy treatment time (P=0.035) and increasing median age (P=0.019) reduced the probability of pCR. The estimated α/β ratio of oesophageal cancer was 4.9 Gy (95% confidence interval (CI) 1.5-17 Gy) and the estimated radiotherapy dose lost per day was 0.59 Gy (95% CI 0.18-0.99 Gy). One gram per square metre of 5FU was estimated to be equivalent to 1.9 Gy (95% CI 0.8-5.2 Gy) of radiation and 100 mg/m 2 of cisplatin was estimated to be equivalent to 7.2 Gy (95% CI 2.1-28 Gy). Mitomycin C dose did not appear to influence pCR rates (P=0.60). Conclusions: There was evidence of a dose-response relationship between increasing protocol prescribed radiotherapy, 5FU and cisplatin dose and pCR. Additional significant factors were radiotherapy

  19. Morphological and structural characterization of CrO2/Cr2O3 films grown by Laser-CVD

    International Nuclear Information System (INIS)

    Sousa, P.M.; Silvestre, A.J.; Popovici, N.; Conde, O.

    2005-01-01

    This work reports on the synthesis of chromium (III, IV) oxides films by KrF laser-assisted CVD. Films were deposited onto sapphire substrates at room temperature by the photodissociation of Cr(CO) 6 in dynamic atmospheres containing oxygen and argon. A study of the processing parameters has shown that partial pressure ratio of O 2 to Cr(CO) 6 and laser fluence are the prominent parameters that have to be accurately controlled in order to co-deposit both the crystalline oxide phases. Films consistent with such a two-phase system were synthesised for a laser fluence of 75 mJ cm -2 and a partial pressure ratio of about 1

  20. Humidity Sensitivity of MgCr2O4-TiO2-LiO2 Ceramics Sensor Prepared by Sol-Gel Routes

    Directory of Open Access Journals (Sweden)

    H. Y. He

    2010-05-01

    Full Text Available 79.5MgCr2O4–19.5TiO2–Li2O porous ceramics were investigated as a humidity sensor. The sensors obtain by a cold isostatic pressing and sintering of the fine MgCr2O4 and TiO2 and LiCO3 powders. The MgCr2O4 and TiO2 powders were respectively synthesized by sol-gel methods. The effects of sintering temperature on the humidity sensitivity of sensors were studied by measuring electrical resistance in different conditions of relative humidity (R.H. at 27 °C. The results indicated that the calcining temperature obviously affected the resistance variation of the sensor in range of 11.3-84.7 % RH. The resistance variation was small at the calcining temperature of 600 oC for 2 h. With increasing calcining temperature, the resistance variation increased to 5.4×104% and 7.0×104 % at 800 oC and 1000 oC for 2 h, but decreased to 3.1×104 % at 1200 oC for 2 h respectively. The response times are 25 s and 35 s respectively for humidity adsorption and humidity desorption between 11.3 %RH and 84.7 %RH.

  1. Evaluation of 2 1/4 Cr-1 Mo steel for liquid lithium containment. II. Effects of post-weld heat treatment and niobium content. Annual report, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, T.L.; Edwards, G.R.

    1979-01-01

    The lithium corrosion resistance of the regular grade of 2 1/4 Cr-1 Mo steel can be vastly improved with a proper postweld heat treatment, but even greater improvements are needed. Results indicate that if weldments were tempered sufficiently long at 760C to remove all Mo/sub 2/C from the microstructure, even greater resistance to attack by low nitrogen lithium could be achieved. Corrosion tests should eventually be performed on regular grade 2 1/4 Cr-1 Mo steel weldments which have been given a long-term (> 25 h) post-weld temper at 760C. Lithium corrosion resistance of regular grade 2 1/4 Cr-1 Mo steel may also be improved by employing a quench and temper heat treatment. Quenched microstructures have more homogenous distribution of carbides than isothermally annealed microstructures, and if properly tempered, should provide excellent lithium corrosion resistance. Furthermore, the toughness of such a lower bainite microstructure should be better than that of the ferrite-bainitic microstructure created by an isothermal anneal. Numerous parameters, all potentially deleterious to the lithium corrosion resistance of 2 1/4 Cr-1 Mo steel, remain to be investigated; two such variables are velocity effects and lead content in the lithium.

  2. Evaluation of 2 1/4 Cr-1 Mo steel for liquid lithium containment. II. Effects of post-weld heat treatment and niobium content. Annual report, 1979

    International Nuclear Information System (INIS)

    Anderson, T.L.; Edwards, G.R.

    1979-01-01

    The lithium corrosion resistance of the regular grade of 2 1/4 Cr-1 Mo steel can be vastly improved with a proper postweld heat treatment, but even greater improvements are needed. Results indicate that if weldments were tempered sufficiently long at 760C to remove all Mo 2 C from the microstructure, even greater resistance to attack by low nitrogen lithium could be achieved. Corrosion tests should eventually be performed on regular grade 2 1/4 Cr-1 Mo steel weldments which have been given a long-term (> 25 h) post-weld temper at 760C. Lithium corrosion resistance of regular grade 2 1/4 Cr-1 Mo steel may also be improved by employing a quench and temper heat treatment. Quenched microstructures have more homogenous distribution of carbides than isothermally annealed microstructures, and if properly tempered, should provide excellent lithium corrosion resistance. Furthermore, the toughness of such a lower bainite microstructure should be better than that of the ferrite-bainitic microstructure created by an isothermal anneal. Numerous parameters, all potentially deleterious to the lithium corrosion resistance of 2 1/4 Cr-1 Mo steel, remain to be investigated; two such variables are velocity effects and lead content in the lithium

  3. MgO–CaO–Cr2O3 composition as a novel refractory brick: Use of Cr2O3 nanoparticles

    Directory of Open Access Journals (Sweden)

    Salman Ghasemi-Kahrizsangi

    2017-03-01

    Full Text Available At this study the effect of Cr2O3 nanoparticles (up to 3 wt.% on the physical and mechanical properties of MgO–CaO refractory composition with emphasis on the hydration resistance improvement have been investigated. Specimens pressed at 90 MPa then were sintered at 1650 °C for 5 h in an electric furnace. Properties such as bulk density, apparent porosity, cold crushing strength and hydration resistance were examined. The crystalline phases and microstructure characteristics of sintered specimens were studied by X-ray diffraction (XRD and scanning electron microscopy (SEM/EDS, respectively. Results shown that add of the 1.5 wt.% Cr2O3 nanoparticles have the best results i.e. increased the bulk density (3.41 g/cm3, cold crushing strength (848 kg/cm2, hydration resistance (1.5% and decreased apparent porosity (5.58%, respectively. The mechanism of specimens hydration resistance improvement are: (i decreasing the amount of free CaO and MgO with converted to high hydration resistance phases such as CaCr2O4 and MgCr2O4 phases, (ii promotion of the densification as well as (iii modification of the microstructure.

  4. Identification of the 1s2s2p 4P5/2-->1s22s 2S1/2 magnetic quadrupole inner-shell satellite line in the Ar16+ K-shell x-ray spectrum

    Science.gov (United States)

    Beiersdorfer, P.; Bitter, M.; Hey, D.; Reed, K. J.

    2002-09-01

    We have identified the dipole-forbidden 1s2s2p 4P5/2-->1s22s 2S1/2 transition in lithiumlike Ar15+ in high-resolution K-shell x-ray emission spectra recorded at the Livermore EBIT-II electron-beam ion trap and the Princeton National Spherical Tokamak Experiment. Unlike other Ar15+ satellite lines, which can be excited by dielectronic recombination, the line is exclusively excited by electron-impact excitation. Its predicted radiative rate is comparable to that of the well-known 1s2p 3P1-->1s2 1S0 magnetic quadrupole transition in heliumlike Ar16+. As a result, it can also only be observed in low-density plasma. We present calculations of the electron-impact excitation cross sections of the innershell excited Ar15+ satellite lines, including the magnetic sublevels needed for calculating the linear line polarization. We compare these calculations to the relative magnitudes of the observed 1s2s2p-->1s22s transitions and find good agreement, confirming the identification of the lithiumlike 1s2s2p 4P5/2-->1s22s 2S1/2 magnetic quadrupole line.

  5. Development of Cr{sub 3}C{sub 2}-25(Ni20Cr) nanostructured coatings; Desenvolvimento de revestimentos nanostruturados de Cr{sub 3}C{sub 2}-25(Ni20Cr)

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Cecilio Alvares da

    2012-07-01

    This study is divided in two parts. The first part is about the preparation of nanostructured Cr{sub 3}C{sub 2}-25(Ni20Cr) powders by high energy milling followed by characterization of the milled and the as received powder. Analyses of some of the data obtained were done using a theoretical approach. The second part of this study is about the preparation and characterization of coatings prepared with the nanostructured as well as the as received Cr{sub 3}C{sub 2}-25(Ni20Cr) powders. The high temperature erosion-oxidation (E-O) behavior of the coatings prepared with the two types of powders has been compared based on a technological approach. The average crystallite size of the Cr{sub 3}C{sub 2}-25(Ni20Cr) powder decreased rapidly from 145 nm to 50 nm in the initial stages of milling and thereafter decreased slowly to a steady state value of around 10 nm with further increase in milling time. This steady state corresponds to the beginning of a dynamic recovery process. The maximum lattice strain ({epsilon} = 1,17%) was observed in powders milled for 16 hours, and this powders critical crystallite size was 28 nm. In contrast, the lattice parameter attained a minimum for powders milled for 16 hours. Upon reaching the critical crystallite size, the dislocation density attained a steady state regime and all plastic deformation introduced in the material there after was in the form of events occurring at the grain boundaries, due mainly to grain boundary sliding. The deformation energy stored in the crystal lattice of the Cr{sub 3}C{sub 2}-25(Ni20Cr) powders milled for different times was determined from enthalpy variation measurements. These results indicated that the maximum enthalpy variation ({delta}H = 722 mcal) also occurred for powders milled for 16 hours. In a similar manner, the maximum specific heat variation ({delta}C{sub p} = 0,278 cal/gK) occurred for powders milled for 16 hours. The following mechanical properties of Cr{sub 3}C{sub 2}-25(Ni20Cr) coatings

  6. Structural, optical and ferromagnetic properties of Cr doped TiO2 nanoparticles

    International Nuclear Information System (INIS)

    Choudhury, Biswajit; Choudhury, Amarjyoti

    2013-01-01

    Graphical abstract: Doping of Cr 3+ distorts the lattice of TiO 2 , generate oxygen vacancies and create d-band states in the mid band gap of TiO 2 . Incorporation of Cr 3+ also imparts magnetism in non-magnetic TiO 2 by undergoing coupling with the neighboring oxygen vacancies. -- Highlights: • Incorporation of Cr 3+ increases the concentration of oxygen vacancies in TiO 2 nanoparticles. • Doped TiO 2 nanoparticles contain absorption peaks corresponding to d–d transition of Cr 3+ into TiO 2 . • Pure and doped TiO 2 nanoparticles contain emission peaks related to oxygen vacancies. • Pure TiO 2 shows diamagnetism while Cr doped TiO 2 shows ferromagnetism. • The ferromagnetism is due to the interaction of Cr 3+ ions via oxygen vacancies. -- Abstract: Cr doped TiO 2 nanoparticles are prepared with three different concentrations of chromium, 1.5%, 3.0% and 4.5 mol% respectively. Doping decreases the crystallinity and increases the width of the X-ray diffraction peak. The Raman active E g peak of TiO 2 nanoparticles become asymmetric and shifted to higher energy on doping of 4.5% chromium. Electron paramagnetic resonance spectra reveal the presence of Cr 3+ in the host TiO 2 matrix. The absorption spectra of Cr doped TiO 2 nanoparticles contain absorption peaks corresponding to d–d transition of Cr 3+ in octahedral coordination. Most of the visible emission peaks are due to the electrons trapped in the oxygen vacancy centers. Undoped TiO 2 nanoparticles show diamagnetism at room temperature while all chromium doped samples show ferromagnetism. The magnetization of the doped samples increases at 1.5% and 3.0% and decreases at 4.5%. The ferromagnetism arises owing to the interaction of the neighboring Cr 3+ ions via oxygen vacancies. The decrease of magnetization at the highest doping is possibly due to the antiferromagnetic interactions of Cr 3+ pairs or due to Cr 3+ -O 2− -Cr 3+ superexchange interaction in the lattice

  7. Modelling Cr(VI) removal by a combined carbon-activated sludge system

    International Nuclear Information System (INIS)

    Orozco, A. Micaela Ferro; Contreras, Edgardo M.; Zaritzky, Noemi E.

    2008-01-01

    The combined carbon-activated sludge process has been proposed as an alternative to protect the biomass against toxic substances in wastewaters; however, the information about the effect of powdered-activated carbon (PAC) addition in activated sludge reactors for the treatment of wastewaters containing Cr(VI) is limited. The objectives of the present study were: (a) to evaluate the removal of hexavalent chromium by (i) activated sludge microorganisms in aerobic batch reactors, (ii) powdered-activated carbon, and (iii) the combined action of powdered-activated carbon and biomass; (b) to propose mathematical models that interpret the experimental results. Different Cr(VI) removal systems were tested: (S1) biomass (activated sludge), (S2) PAC, and (S3) the combined activated carbon-biomass system. A Monod-based mathematical model was used to describe the kinetics of Cr(VI) removal in the system S1. A first-order kinetics with respect to Cr(VI) and PAC respectively, was proposed to model the removal of Cr(VI) in the system S2. Cr(VI) removal in the combined carbon-biomass system (S3) was faster than both Cr(VI) removal using PAC or activated sludge individually. Results showed that the removal of Cr(VI) using the activated carbon-biomass system (S3) was adequately described by combining the kinetic equations proposed for the systems S1 and S2

  8. Chromium isotope variations (δ53/52Cr) in mantle-derived sources and their weathering products: Implications for environmental studies and the evolution of δ53/52Cr in the Earth’s mantle over geologic time

    Science.gov (United States)

    Farkaš, Juraj; Chrastný, Vladislav; Novák, Martin; Čadkova, Eva; Pašava, Jan; Chakrabarti, Ramananda; Jacobsen, Stein B.; Ackerman, Lukáš; Bullen, Thomas D.

    2013-12-01

    Here we report chromium isotope compositions, expressed as δ53/52Cr in per mil (‰) relative to NIST 979, measured in selected Cr-rich minerals and rocks formed by the primary magmatic as well as the secondary metamorphic and weathering processes. The main objectives of this study were: (i) to further constrain the isotope composition of the Earth’s mantle Cr inventory and its possible variation during geological history, based on the analysis of globally distributed and stratigraphically constrained mantle-derived chromites; and (ii) to investigate the magnitude and systematics of Cr isotope fractionation during oxidative weathering and secondary alteration (i.e., hydration, serpentinization) of the magmatic Cr sources. Specifically, we analyzed δ53/52Cr in a set of globally distributed mantle-derived chromites (FeMgCr2O4, n = 30) collected from various locations in Europe, Asia, Africa and South America, and our results confirm that a chromite-hosted Earth’s mantle Cr inventory is uniform at -0.079 ± 0.129‰ (2SD), which we named here as a ‘canonical’ mantle δ53/52Cr signature. Furthermore our dataset of stratigraphically constrained chromites, whose crystallization ages cover most of the Earth’s geological history, indicate that the bulk Cr isotope composition of the chromite-hosted mantle inventory has remained uniform, within about ±0.100‰, since at least the Early Archean times (∼3500 million years ago, Ma). To investigate the systematics of Cr isotope fractionation associated with alteration processes we analyzed a number of secondary Cr-rich minerals and variably altered ultramafic rocks (i.e., serpentinized harzburgites, lherzolites) that revealed large positive δ53/52Cr anomalies that are systematically shifted to higher values with an increasing degree of alteration and serpentinization. The degree of aqueous alteration and serpentinization was quantified by the abundances of fluid-mobile (Rb, K) elements, and by the Loss On

  9. Pathophysiological Consequences of a Break in S1P1-Dependent Homeostasis of Vascular Permeability Revealed by S1P1 Competitive Antagonism.

    Science.gov (United States)

    Bigaud, Marc; Dincer, Zuhal; Bollbuck, Birgit; Dawson, Janet; Beckmann, Nicolau; Beerli, Christian; Fishli-Cavelti, Gina; Nahler, Michaela; Angst, Daniela; Janser, Philipp; Otto, Heike; Rosner, Elisabeth; Hersperger, Rene; Bruns, Christian; Quancard, Jean

    2016-01-01

    Homeostasis of vascular barriers depends upon sphingosine 1-phosphate (S1P) signaling via the S1P1 receptor. Accordingly, S1P1 competitive antagonism is known to reduce vascular barrier integrity with still unclear pathophysiological consequences. This was explored in the present study using NIBR-0213, a potent and selective S1P1 competitive antagonist. NIBR-0213 was tolerated at the efficacious oral dose of 30 mg/kg BID in the rat adjuvant-induced arthritis (AiA) model, with no sign of labored breathing. However, it induced dose-dependent acute vascular pulmonary leakage and pleural effusion that fully resolved within 3-4 days, as evidenced by MRI monitoring. At the supra-maximal oral dose of 300 mg/kg QD, NIBR-0213 impaired lung function (with increased breathing rate and reduced tidal volume) within the first 24 hrs. Two weeks of NIBR-0213 oral dosing at 30, 100 and 300 mg/kg QD induced moderate pulmonary changes, characterized by alveolar wall thickening, macrophage accumulation, fibrosis, micro-hemorrhage, edema and necrosis. In addition to this picture of chronic inflammation, perivascular edema and myofiber degeneration observed in the heart were also indicative of vascular leakage and its consequences. Overall, these observations suggest that, in the rat, the lung is the main target organ for the S1P1 competitive antagonism-induced acute vascular leakage, which appears first as transient and asymptomatic but could lead, upon chronic dosing, to lung remodeling with functional impairments. Hence, this not only raises the question of organ specificity in the homeostasis of vascular barriers, but also provides insight into the pre-clinical evaluation of a potential safety window for S1P1 competitive antagonists as drug candidates.

  10. First-principles study on half-metallic zinc-blende CrS and its (001) surface

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Bin, E-mail: hnsqxb@163.com [Department of Mathematics and Information Sciences, North China university of Water Resources and Electric Power, Zhengzhou 450011 (China); Chen, Leiming [Zhengzhou Institute of Aeronautical Industry Management, Zhengzhou, 450015 (China)

    2016-11-01

    Half-metallic magnets with complete (100%) spin polarization have attracted growing interest due to the potential in spintronic applications. In this paper, we use the first-principles calculations to explain the seeming contradiction between the recent experimental ferromagnetism (Demper et al., 2012 [22]) and the previous theoretical antiferromagnetic ground state for half-metallic zinc-blende CrS, and the experimental ferromagnetism of zinc-blende CrS arises from the substrate effect. We also show that both Cr- and S-terminated (001) surfaces of CrS preserve the bulk half-metallicity. The calculated surface energy indicates that the S-terminated (001) surface is more stable than the Cr-terminated (001) surface within the whole effective Cr chemical potentials, and thus the S-terminated (001) surface is more likely than the Cr-terminated (001) surface when the CrS thin films are grown on ZnSe substrate.

  11. Study of the oxidation of Fe-Cr alloys at high temperatures; Estudo da oxidacao de ligas Fe-Cr a altas temperaturas

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J.F.; Sabioni, A.C.S. [Universidade Federal de Ouro Preto (LDM/DF/UFOP), MG (Brazil). Dept. de Fisica. Lab. de Difusao em Materiais; Trindade, V.B. [Universidade Federal de Ouro Preto (DEMM/UFOP), MG (Brazil). Dept. de Engenharia Metalurgica e de Materiais; Ji, V. [Laboratoire d' Etude des Materiaux Hors-Equilibre (LEMHE), Orsay (France)

    2010-07-01

    The high temperature oxidation behavior of Fe-1.5%Cr, Fe-5.0%Cr, Fe-10%Cr and Fe- 15%Cr model alloys were investigated from 700 to 850 deg C, in air atmosphere. The oxidation treatments were performed in a thermobalance with a sensitivity of 1{mu}g. The oxide films grown by oxidation of the alloys were characterized by scanning electronic microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The oxide films are Fe-Cr spinels with variable composition depending on the alloy composition. For all conditions studied, the oxidation kinetics of these alloys follow a parabolic law. The comparison of the oxidation rates of the four alloys, at 700 deg C, shows that the parabolic oxidation constants decrease from 1.96x10{sup -9}g{sup 2}.cm{sup -4}.s{sup -1}, for the alloy Fe-1.5% Cr, to 1.18 x 10-14g{sup 2}.cm{sup -4}.s{sup -1} for the alloy Fe-15% Cr. Comparative analysis of the oxidation behavior of the Fe-10%Cr and Fe-15%Cr alloys, between 700 and 850 deg C, shows that the oxidation rates of these alloys are comparable to 800 deg C, above this temperature the Fe-10%Cr alloy shows lower resistance to oxidation. (author)

  12. Impact properties of 2 1/4 Cr--1 Mo steel after ten years EBR-II service

    International Nuclear Information System (INIS)

    Shields, J.A.; Server, W.L.; Sheckherd, J.W.; Longua, K.J.

    1976-01-01

    The material studied in this investigation was obtained from a 2 1 / 4 Cr--1 Mo steel superheated steam line which had been in service for approximately 90,000 hours. Of that 90,000 hours, approximately 40,000 hours were at a temperature of approximately 820 0 F and a pressure of 1250 psi, and 35,000 hours were at a temperature of 500 0 F and 1250 psi. The results of optical metallography and instrumented impact testing performed on the materials are presented

  13. Efficient Pd@MIL-101(Cr) hetero-catalysts for 2-butyne-1,4-diol hydrogenation exhibiting high selectivity

    KAUST Repository

    Yin, Dongdong; Li, Chuang; Ren, Hangxing; Shekhah, Osama; Liu, Jinxuan; Liang, Changhai

    2017-01-01

    Pd@MIL-101(Cr) hetero-catalysts have been successfully prepared using the metal-organic chemical vapour deposition (MOCVD) approach, by choosing [Pd(η-CH)(η-CH)] as a volatile precursor, and the hydrothermally stable metal-organic framework, MIL-101

  14. Synthesis and structural stability of Cr-doped Li2MnSiO4/C cathode materials by solid-state method

    Science.gov (United States)

    Cheng, Hong-Mei; Zhao, Shi-Xi; Wu, Xia; Zhao, Jian-Wei; Wei, Lei; Nan, Ce-Wen

    2018-03-01

    The crystal structure of the Li2MnSiO4 cathode material would collapse during the charge and discharge process because of that the Mn-O coordination polyhedron changed from [MnO4] into [MnO6] in the process of Mn+2 to Mn+4, but the Cr element could remain [CrO4] crystal ligand from Cr+2 to Cr+4, so Cr element substitution was used to improve the structural stability of the Li2MnSiO4 cathode material. In this work, Li2Mn1-xCrxSiO4/C nanocomposites were synthesized by solid-state method. XRD, SEM and TEM observations show that the as-prepared Li2Mn1-xCrxSiO4/C materials presents an orthorhombic crystal structure (S.G. Pmn21), the particle size of Li2Mn1-xCrxSiO4/C powder ranges from 50 to 100 nm. The XRD and XPS results indicate that Cr+2 is successfully doped into Li2MnSiO4 lattice and has well compatibility with Li2MnSiO4. The electrochemical results display that Li2Mn92.5%Cr7.5%SiO4/C exhibits significantly enhanced cycle stability and discharge capability. The initial discharge capacity of the Li2Mn92.5%Cr7.5%SiO4/C sample is 255 mAh g-1, and the discharge capacity was still about 60 mAh g-1 after 50 cycles. Furthermore, the XRD patterns, TEM images and Raman analysis reveal that the Cr doping enhances the structural stability of Li2Mn1-xCrxSiO4/C and improves the electrochemical activity of the cathode. Thus, the Li2Mn92.5%Cr7.5%SiO4/C have shown potential applications for lithium ion batteries.

  15. New carbazole-based Schiff base: Colorimetric chemosensor for Fe{sup 3+} and fluorescent turn-on chemosensor for Fe{sup 3+} and Cr{sup 3+}

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Weiju; Yang, Lianlian; Fang, Min; Wu, Zhenyu; Zhang, Qing; Yin, Fangfang; Huang, Qiang; Li, Cun, E-mail: cun_li@126.com

    2015-02-15

    Two novel carbazole-based Schiff-bases L1 and L2 have been synthesized and characterized by {sup 1}H NMR, {sup 13}C NMR, FT-IR spectroscopy and elemental analysis. L1 can selectively detect Fe{sup 3+} by UV–vis spectroscopy and Fe{sup 3+}/Cr{sup 3+} by fluorescent spectroscopy in CH{sub 3}CN among various metal ions. The addition of Fe{sup 3+} ions to a L1 solution results in a significant blue-shift from 410 nm to 378 nm accompanied with color change from yellowish green to colorless. Upon excitation at 380 nm, the addition of Fe{sup 3+} or Cr{sup 3+} causes a 13-fold or 11-fold fluorescence enhancement. The binding stoichiometry ratio of L1–Fe{sup 3+} and L1Cr{sup 3+} is recognized as 2:1 by the method of Job's plot, and the possible binding mode of the system also proposes. The results indicate that L1 is an ideal chemosensor for Fe{sup 3+} and Cr{sup 3+} recognition. However, L2 without hydroxyl in ortho imino group cannot selectively recognize the tasted metal ions, indicating that the introduction of the appropriate coordination binding site to receptor can improve efficiently the selectivity of chemosensor. - Highlights: • We designed and synthesized two new carbazole-based Schiff bases L1 and L2. • L1 could selectively recognize Fe{sup 3+} but L2 could not, which suggested that increase recognition site helped to improve the selectivity of probe. • L1 not only could serve as a highly selective visual chemosensor for Fe{sup 3+} ion without the aid of any instruments, but also could be used as a fluorescent chemosensor for Fe{sup 3+} and Cr{sup 3+}.

  16. Elevated-Temperature Corrosion of CoCrCuFeNiAl0.5Bx High-Entropy Alloys in Simulated Syngas Containing H2S

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, Omer N; Nielsen, Benjamin C; Hawk, Jeffrey A

    2013-08-01

    High-entropy alloys are formed by synthesizing five or more principal elements in equimolar or near equimolar concentrations. Microstructure of the CoCrCuFeNiAl{sub 0.5}B{sub x} (x = 0, 0.2, 0.6, 1) high-entropy alloys under investigation is composed of a mixture of disordered bcc and fcc phases and borides. These alloys were tested gravimetrically for their corrosion resistance in simulated syngas containing 0, 0.01, 0.1, and 1 % H{sub 2}S at 500 °C. The exposed coupons were characterized using XRD and SEM. No significant corrosion was detected at 500 °C in syngas containing 0 and 0.01 % H{sub 2}S while significant corrosion was observed in syngas containing 0.1 and 1 % H{sub 2}S. Cu{sub 1.96}S was the primary sulfide in the external corrosion scale on the low-boron high-entropy alloys, whereas FeCo{sub 4}Ni{sub 4}S{sub 8} on the high-boron high-entropy alloys. Multi-phase Cu-rich regions in the low-B high-entropy alloys were vulnerable to corrosive attack.

  17. Dose control during decommissioning stage 1.2 of decommissioning SGHWR facility

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, M.J. [AEA Technology (United Kingdom)

    1995-12-31

    Dose control during decommissioning stage 1.2 of the SGHWR facility, i.e preparation for an extended period of care and maintenance, is discussed. The method of control of dose uptake is described and also the systems of dose uptake review, the use of dose restraint objections and other tools for limitation of dose uptake. Dose uptake data are presented for periods of maintenance shutdowns. Finally the option of chemical clearing of the circuit following shutdown is considered. (UK).

  18. Removal of Cr(VI Ions from Aqueous Solutions Using Nickel Ferrite Nanoparticles: Kinetic and Equilibrium Study

    Directory of Open Access Journals (Sweden)

    Raziyeh Zandi Pak

    2017-01-01

    Full Text Available Background & Aims of the Study: Heavy metals are the most important and main pollutants because of their accumulation and high toxicity even at very low dose and cause serious hazards to ecological system as well as human health. Thus, their removal has been challenged from drinking water and industrial waters with different technologies. The purpose of this work is to investigate the removal of Cr(VI from aqueous solutions. Materials & Methods: NiFe2O4 nanoparticles was prepared by the co-precipitation method and then applied for adsorption of Cr(VI ions from water. Characterization of nanoparticles was carried out via TEM, EDX, XRD and BET analysis. Various physico-chemical parameters like the effect of contact time, pH and adsorbent dose were studied, using batch process to optimize conditions for maximum adsorption. Results: The results demonstrated that the size of the NiFe2O4 nanoparticles was about 12 nm and had selectivity for Cr(VI adsorption. Also, adsorption process was found to be fast with equilibrium time of 55 min. Optimum pH was found to be 3. Maximum adsorption capacity (qm as calculated from Langmuir isotherm was found to be 294.1 mg g-1. Analysis of adsorption kinetics indicated better applicability of pseudo-second-order kinetic model. Conclusions: The results of this study represented that the synthesized NiFe2O4 nanoparticles could be useful for the simultaneous removal of anionic ions from wastewaters.

  19. Stimulant effects of adenosine antagonists on operant behavior: differential actions of selective A2A and A1 antagonists

    Science.gov (United States)

    Randall, Patrick A.; Nunes, Eric J.; Janniere, Simone L.; Stopper, Colin M.; Farrar, Andrew M.; Sager, Thomas N.; Baqi, Younis; Hockemeyer, Jörg; Müller, Christa E.

    2012-01-01

    Rationale Adenosine A2A antagonists can reverse many of the behavioral effects of dopamine antagonists, including actions on instrumental behavior. However, little is known about the effects of selective adenosine antagonists on operant behavior when these drugs are administered alone. Objective The present studies were undertaken to investigate the potential for rate-dependent stimulant effects of both selective and nonselective adenosine antagonists. Methods Six drugs were tested: two nonselective adenosine antagonists (caffeine and theophylline), two adenosine A1 antagonists (DPCPX and CPT), and two adenosine A2A antagonists (istradefylline (KW6002) and MSX-3). Two schedules of reinforcement were employed; a fixed interval 240-s (FI-240 sec) schedule was used to generate low baseline rates of responding and a fixed ratio 20 (FR20) schedule generated high rates. Results Caffeine and theophylline produced rate-dependent effects on lever pressing, increasing responding on the FI-240 sec schedule but decreasing responding on the FR20 schedule. The A2A antagonists MSX-3 and istradefylline increased FI-240 sec lever pressing but did not suppress FR20 lever pressing in the dose range tested. In fact, there was a tendency for istradefylline to increase FR20 responding at a moderate dose. A1 antagonists failed to increase lever pressing rate, but DPCPX decreased FR20 responding at higher doses. Conclusions These results suggest that adenosine A2A antagonists enhance operant response rates, but A1 antagonists do not. The involvement of adenosine A2A receptors in regulating aspects of instrumental response output and behavioral activation may have implications for the treatment of effort-related psychiatric dysfunctions, such as psychomotor slowing and anergia in depression. PMID:21347642

  20. CrWSKP1, an SKP1-like Gene, Is Involved in the Self-Incompatibility Reaction of "Wuzishatangju" (Citrus reticulata Blanco).

    Science.gov (United States)

    Li, Peng; Miao, Hongxia; Ma, Yuewen; Wang, Lu; Hu, Guibing; Ye, Zixing; Zhao, Jietang; Qin, Yonghua

    2015-09-09

    Plant S-phase kinase-associated protein 1 (SKP1) genes play crucial roles in plant development and differentiation. However, the role of SKP1 in citrus is unclear. Herein, we described a novel SKP1-like gene, designated as CrWSKP1, from "Wuzishatangju" (Citrus reticulata Blanco). The cDNA sequence of CrWSKP1 is 779 base pairs (bp) and contains an open reading frame (ORF) of 477 bp. The genomic sequence of the CrWSKP1 gene is 1296 bp with two exons and one intron. CrWSKP1 has high identity with SKP1-like genes from other plant species within two conserved regions. Approximately 85% of pollen tubes of self-pollinated CrWSKP1 transgenic tobaccos became twisted at four days after self-pollination. Pollen tube numbers of self-pollinated CrWSKP1 transformants entering into ovules were significantly fewer than that of the control. Seed number of self-pollinated CrWSKP1 transformants was significantly reduced. These results suggested that the CrWSKP1 is involved in the self-incompatibility (SI) reaction of "Wuzishatangju".

  1. High-Temperature Corrosion of T92 Steel in N{sub 2}/H{sub 2}O/H{sub 2}S-Mixed Gas

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yuke; Kim, Min Jung; Park, Soon Yong; Abro, M. Ali; Yadav, Poonam; Lee, Dong Bok [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-06-15

    The ASTM T92 steel was corroded at 600 ℃ and 800 ℃ at 1 atm of N{sub 2}/3.1%H{sub 2}O/2.42%H{sub 2}S-mixed gas. The formed scales were thick and fragile. They consisted primarily of the outer FeS scale and the inner (FeS, FeCr{sub 2}S{sub 4})-mixed scale containing a small amount of the Cr{sub 2}O{sub 3} scale. This indicated that corrosion occurred mainly via sulfidation rather than oxidation due to the H{sub 2}S gas. Since FeS was present throughout the whole scale, T92 steel was non-protective, displaying high corrosion rates.

  2. Deuterons at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2011-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to deuterons ( 2 H + ) in the energy range 10 MeV -1 TeV (0.01-1000 GeV). Coefficients were calculated using the Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of the effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Coefficients for the equivalent and effective dose incorporated a radiation weighting factor of 2. At 15 of 19 energies for which coefficients for the effective dose were calculated, coefficients based on ICRP 1990 and 2007 recommendations differed by < 3 %. The greatest difference, 47 %, occurred at 30 MeV. (authors)

  3. Black Cr/α-Cr2O3 nanoparticles based solar absorbers

    International Nuclear Information System (INIS)

    Khamlich, S.; Nemraoui, O.; Mongwaketsi, N.; McCrindle, R.; Cingo, N.; Maaza, M.

    2012-01-01

    Monodisperse spherical core–shell particles of Cr/α-Cr 2 O 3 with high adhesion were successfully coated on rough copper substrates by a simple self-assembly-like method for the use in solar thermal absorbers. The structure and morphology of the core-shell particles of Cr/α-Cr 2 O 3 were effectively controlled by deposition temperature and the pH of the initial precursor solution. Their characterizations were carried out with X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry and attenuated total reflection, as well as UV–vis diffuse reflectance spectroscopy. The samples aged for more than 40 h at 75 °C exhibit the targeted high absorbing optical characteristic “Black chrome” while those aged for ≤40 h show a significant high UV–vis diffuse reflectance “green color”.

  4. Tensile flow behaviour of 2.25Cr-1Mo ferritic steel base metal an simulated heat affected zone structures of 2.25 Cr-1Mo weld joint

    International Nuclear Information System (INIS)

    Laha, K.; Chandravathi, K.S.; Rao, K.B.S.; Mannan, S. L.; Sastry, D.H.

    1999-01-01

    Tensile tests in the temperature range 298 to 873 K have been performed on 2.25Cr-1Mo base metal and simulated heat affected zone (HAZ) structures of its weld joint, namely coarse grain bainite, fine grain bainite and intercritical structure. Tensile flow behaviour of all the microstructural conditions could be adequately described by the Hollomon equation (σ = K 1 ε n1 ) at higher (>623 K) temperatures. Deviation from the Hollomon equation was observed at low strains and lower ( 1 ε n1 + exp (K 2 + n 2 ε), was found to describe the flow curve. In general, the flow parameters n 1 , K 1 , n 2 and K 2 were found to decrease with increase in temperature except in the intermediate temperature range (423 to 623 K). Peaks/plateaus were observed in their variation with temperature in the intermediate temperature range coinciding with the occurrence of serrated flow in the load-elongation curve. The n 1 value increased and the K 1 value decreased with the type of microstructure in the order: coarse grain bainite, fine grain bainite, base metal and intercritical structure. The variation of n 1 with microstructure has been rationalized on the basis of mean free path (MFP) of dislocations which is directly related to the inter-particle spacing. Larger MFP of dislocations lead to higher strain hardening exponents n 1 . (orig.)

  5. Electron spin resonance study of a-Cr2O3 and Cr2O3·nH2O quasi-spherical nanoparticles

    CSIR Research Space (South Africa)

    Khamlich, S

    2011-12-01

    Full Text Available The quasi-spherical nanoparticles of hydrated Cr2O3 · nH2O, and crystalline -Cr2O3, have been synthesized by reduction of the first row (3d) transition metal complex of K2Cr2O7. The temperaturedependence of electron spin resonance (ESR) spectrum...

  6. Spin correlations in the pyrochlore slab compounds Ba2Sn2Ga10-7pZnCr7pO22

    International Nuclear Information System (INIS)

    Bonnet, P; Payen, C; Mutka, H; Danot, M; Fabritchnyi, P; Stewart, J R; Mellergaard, A; Ritter, C

    2004-01-01

    The low-temperature properties of a diluted antiferromagnetic pyrochlore slab of S = 3/2 spins are investigated through a study of the frustrated oxides Ba 2 Sn 2 Ga 10-7p ZnCr 7p O 22 (p>0.85). Powder neutron diffraction and 119 Sn Moessbauer absorption show no evidence of long-range magnetic order above 1.5 K. As in SrCr 9q Ga 12-9q O 19 , diffuse magnetic scattering, indicative of short range spin-spin correlations, is observed at low temperature. The dependence of the low-temperature sub-Curie bulk susceptibility to weak site depletion is the inverse of that observed in SrCr 9q Ga 12-9q O 19

  7. Selective agonists at group II metabotropic glutamate receptors: synthesis, stereochemistry, and molecular pharmacology of (S)- and (R)-2-amino-4-(4-hydroxy[1,2,5]thiadiazol-3-yl)butyric acid

    DEFF Research Database (Denmark)

    Clausen, Rasmus P; Bräuner-Osborne, Hans; Greenwood, Jeremy R

    2002-01-01

    Homologation of analogues of the central excitatory neurotransmitter glutamic acid (Glu), in which the distal carboxy group has been bioisosterically replaced by acidic heterocyclic units, has previously provided subtype selective ligands for metabotropic Glu receptors (mGluRs). The (S......)-form of the 1,2,5-thiadiazol-3-ol Glu analogue, 2-amino-3-(4-hydroxy[1,2,5]thiadiazol-3-yl)propionic acid (TDPA, 6), is an 2-amino-3-(3-hydroxy-5-methyl-4-isoxazolyl)propionic acid (AMPA) receptor agonist, which in addition stereospecifically activates group I mGluRs. We have now synthesized the (S)- and (R......)-forms of 2-amino-4-(4-hydroxy[1,2,5]thiadiazol-3-yl)butyric acid (homo-TDPA, 7) and shown that whereas neither enantiomer interacts with AMPA receptors, (S)- and (R)-7 appear to be selective and equipotent agonists at group II mGluRs as represented by the mGluR2 subtype. The activities of (S)- and (R)-7...

  8. Spin flip at unelastic scattering of protons with energy near 6 NeV o 50Cr and 52Cr nuclei

    International Nuclear Information System (INIS)

    Andronov, Yu.F.; Chubinskij, O.V.; Vinogradov, L.I.; Ehl'-Ashri, F.I.; Gustova, L.V.

    1978-01-01

    Angular S(Q) and energy S(E) dependences spin flip probability S were studied in inelastic scattering of protons with excitation of the 2 1 + states of 50 Cr (Q=-0.782 MeV) and 52 Cr (Q=-1.434 MeV) energy range from 5.6 to 5.95 MeV. In particular, it is elucidated how strongly the behaviour of the spin flip probability depends upon the energy and angle of scattering at Esub(p) approximately 6 MeV for 50 Cr and 52 Cr. Thereby some additional information on specific features of the mechanism of inelastic sccattering by th nuclei is obtained. Measurements were carried out simultaneously in two proton detection channels at scattering angles differing by 30 deg. For targets use was made of self-sustaining enriched foils (87% 50 Cr and 99% 52 Cr). The angular and energy dependences of the spin flip probabilities for 50 Cr and 52 Cr are shown to be rather different: for 52 Cr has a relatively slight energy dependence in the range of a resonance observed in the excitation function; for 50 Cr the behaviour of S(E) undergoes sharp changes. The experimetnal values of S(Q) for sup(50, 52)Cr differ rather strongly from the calculations made on the statistical model and depend considerably upon the scattering angle

  9. Soft zone formation in dissimilar welds between two Cr-Mo steels

    International Nuclear Information System (INIS)

    Albert, S.K.; Gill, T.P.S.; Tyagi, A.K.; Mannan, S.L.; Rodriguez, P.; Kulkarni, S.D.

    1997-01-01

    Two dissimilar weldments between 9Cr-1Mo and 2.25Cr-1Mo ferritic steels have been characterized for their microstructural stability during various postweld heat treatments (PWHTs). The samples for the investigation were extracted from bead-on-plate weldments made by depositing 2.25Cr-1Mo weld metal on 9Cr-1Mo base plate and vice versa. Subsequent application of PWHT resulted in the formation of a soft zone in the low Cr ferritic steel weld or base plate. A carbide-rich hard zone, adjoining the soft zone, was also detected in the high Cr side of the weldment. Unmixed zones in the weld metal provided additional soft and hard zones in the weld metals. The migration of carbon from low-Cr steel to high-Cr steel, driven by the carbon activity gradient, has been shown to be responsible for the formation of soft and hard zones. A carbon activity diagram for 2.25Cr-1Mo/9Cr-1Mo weldments has been proposed to aid in the selection of welding consumables for reducing or preventing the soft zone formation

  10. Mesorad dose assessment model. Volume 1. Technical basis

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Bander, T.J.; Athey, G.F.; Ramsdell, J.V.

    1986-03-01

    MESORAD is a dose assessment model for emergency response applications. Using release data for as many as 50 radionuclides, the model calculates: (1) external doses resulting from exposure to radiation emitted by radionuclides contained in elevated or deposited material; (2) internal dose commitment resulting from inhalation; and (3) total whole-body doses. External doses from airborne material are calculated using semi-infinite and finite cloud approximations. At each stage in model execution, the appropriate approximation is selected after considering the cloud dimensions. Atmospheric processes are represented in MESORAD by a combination of Lagrangian puff and Gaussian plume dispersion models, a source depletion (deposition velocity) dry deposition model, and a wet deposition model using washout coefficients based on precipitation rates

  11. Matrix isolation and theoretical study of the photochemical reactions of C{sub 2}H{sub 3}Br and 1,2-C{sub 2}H{sub 2}Br{sub 2} with CrO{sub 2}Cl{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, Christine E. [Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221 (United States); Goldberg, Nicola [Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221 (United States); Klein-Riffle, Evan T. [Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221 (United States); Kronberg, Jon K. [Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221 (United States); Ault, Bruce S. [Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221 (United States)], E-mail: bruce.ault@uc.edu

    2006-08-01

    The matrix-isolation technique has been combined with infrared spectroscopy and theoretical calculations to characterize the products of the photochemical reactions of C{sub 2}H{sub 3}Br and 1,2-C{sub 2}H{sub 2}Br{sub 2} with CrO{sub 2}Cl{sub 2}. For these systems, oxygen-atom transfer occurred upon visible-near ultraviolet irradiation, yielding bromoacetaldehyde and CrOCl{sub 2} in the former case and bromoacetyl bromide and CrCl{sub 2}O in the latter. For each system, the products were formed in the same matrix cage and strongly interacted to form a distinct molecular complex. No evidence was obtained for the acetyl bromide derivative in the C{sub 2}H{sub 3}Br system, indicating the occurrence of oxygen-atom attack at the less substituted carbon of vinyl bromide, nor was any evidence obtained for the formation of a possible five-membered metallocycle. Two different modes of interaction were explored computationally: {eta}{sup 1} (end-on) to the oxygen atom and {eta}{sup 2} (side-on) to the C=O bond. Theoretical calculations indicated that the {eta}{sup 1} complex of CH{sub 2}BrCHO-CrCl{sub 2}O was 13 kcal mol{sup -1} more stable than the {eta}{sup 2} complex at the B3LYP/6-311++G(d,2p) level of theory. The binding energy of the {eta}{sup 1} complex was found to be 21 kcal mol{sup -1}, compared to 8 kcal mol{sup -1} for the {eta}{sup 2} complex at this level of theory.

  12. Effect of cold work on decarburization of 2.25Cr-1Mo steel in high temperature sodium

    International Nuclear Information System (INIS)

    Aoki, Norichika; Yoshida, Eiichi; Wada, Yusaku.

    1994-01-01

    It is known that the mechanical properties of a 2.25Cr-1Mo steel deteriorated due to the decarburization during immersion in the melt sodium at high temperatures. In low-alloy steel as well as a 2.25Cr-1Mo steel, precipitation reactions of carbides are known to be accelerated by cold working and aging. Thus, it may be expected that cold working and aging effectively suppress the decarburization of the mechanical properties of a 2.25Cr-1Mo steel because the decarburization will be restrained owing to fixation of carbon as precipitates of the carbides. In the present article, effects of cold-working and heat treatments on the kinetics of the decarburization of a 2.25Cr-1Mo steel has been studied experimentally. The annealed, cold-rolled, and normalized and tempered specimens were immersed in the melt of sodium at 500, 600 and 700degC for 425, 437 and 432h, respectively. On the basis of the observations obtained from these specimens, the experiment was also carried out at 450, 500 and 550degC for 2270 and 5465h. The microstructures before and after the immersion were observed with optical and scanning electron microscopes. An average concentration of carbon in each specimen was analyzed by an inert gas fusion method. The carbides extracted from the specimens were identified by X-ray diffraction. At immersion temperatures of 450 and 500degC, a 10% reduction of the decarburization in thickness by cold-working is sufficiently effective for retardation of the decarburization at both 2270 and 5465h. Whereas, at 550degC, more than 30% reduction in thickness by cold-working is needed for it at 2270h but even 80% reduction in thickness by cold-working causes merely slight retardation of the decarburization at 5465h. (author)

  13. Response of duplex Cr(N)/S and Cr(C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions.

    Science.gov (United States)

    Sun, Y; Dearnley, P A; Mallia, Bertram

    2017-08-01

    Two duplex coatings, Cr(N)/S and Cr(C)/S, were deposited on 316 L stainless steel by magnetron sputtering. The effectiveness of these duplex coatings in improving the tribocorrosion behavior of medical alloys under elastic contact conditions has been demonstrated in a recent publication. The present work focused on the response of these duplex coatings to tribocorrosion under plastic contact conditions. Tribocorrosion tests were conducted in 0.89% NaCl solution at 37°C at an initial contact pressure of 740 MPa and under unidirectional sliding conditions for sliding duration up to 24 h. The results showed that during sliding in the corrosive solution, the duplex coatings were plastically deformed into the substrate to a depth about 1 μm. The Cr(C)/S duplex coating had sufficient ductility to accommodate the deformation without cracking, such that it was worn through gradually, leading to the gradual increase in open circuit potential (OCP) and coefficient of friction (COF). On the other hand, the Cr(N)/S duplex coating suffered from cracking at all tested potentials, leading to coating blistering after prolonged sliding at OCP and stable pit formation in the substrate beneath the coating at applied anodic potentials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1503-1513, 2017. © 2016 Wiley Periodicals, Inc.

  14. Synthesis and crystal structures of two α-bromoamides, (2'R,1S,2S)-N(2-bromopropanoyl)-2-amino-1-phenylpropane-1,3-diol and (2'S,5S,6S)-N(2-bromopropanoyl)-5-amino-6-phenyl-2-oxo-1,3,2-dioxathiane

    International Nuclear Information System (INIS)

    English, R.B.; Liddell, R.J.; Whiteley, C.G.

    1987-01-01

    One pair of diastereomeric bromoamides, (2'R,1S,2S)- and (2'S,1S,2S)-N(2-bromopropanoyl)-2-amino-1-phenylpropane-1,3-diol have been synthesized from ethyl 2-bromopropionate and an optically active amino-diol. The crystal structures of both were determined from single-crystal X-ray analyses. Both compounds are orthorhombic with space group P2 1 2 1 2 1 with Z = 4 in a unit cell of dimensions a 22,124(5),b 12,812(5), and c 4,886(5)A and a 15,510(5), b 9,707(5), and c 9,457(5)A. The proton chemical shifts of the groups attached to the asymmetric centre C(2'), and consequently, the identification of the configuration of the molecules, were resolved with the help of high-resolution nuclear magnetic resonance

  15. Effect of Gamma Rays on Fast Neutron Registration in CR-39

    CERN Document Server

    Kobzev, A P; El-Halem, A A; Abdul-Ghaphar, U S; Salama, T A

    2002-01-01

    A set of CR-39 plastic detectors with front PE radiator was exposed to Am-Be neutron source, which has an emission rate of 0.86\\cdot 10^{7} sec^{-1}, and the neutron dose equivalent rate 1 m apart from the source is equal to 11 mrem/hr. Another set of samples was irradiated by a neutron dose of 4 rem, then exposed to different gamma-ray doses using ^{60}Co source. It was found that the track density grows with the increase of neutron dose and etching time. It was also found that the bulk etching rate V_{B}, the track diameter and the sensitivity of the CR-39 plastic detector with respect to the neutron irradiation increased with increasing gamma-ray dose in the range 1?10 Mrad. These results show that CR-39 can be considered as a promising fast neutron dosimeter and gamma-ray dosimeter.

  16. Hydrogen storage in TiCr1.2(FeV)x BCC solid solutions

    International Nuclear Information System (INIS)

    Santos, Sydney F.; Huot, Jacques

    2009-01-01

    The Ti-V-based BCC solid solutions have been considered attractive candidates for hydrogen storage due to their relatively large hydrogen absorbing capacities near room temperature. In spite of this, improvements of some issues should be achieved to allow the technological applications of these alloys. Higher reversible hydrogen storage capacity, decreasing the hysteresis of PCI curves, and decrease in the cost of the raw materials are needed. In the case of vanadium-rich BCC solid solutions, which usually have large hydrogen storage capacities, the search for raw materials with lower cost is mandatory since pure vanadium is quite expensive. Recently, the substitutions of vanadium in these alloys have been tried and some interesting results were achieved by replacing vanadium by commercial ferrovanadium (FeV) alloy. In the present work, this approach was also adopted and TiCr 1.2 (FeV) x alloy series was investigated. The XRD patterns showed the co-existence of a BCC solid solution and a C14 Laves phase in these alloys. SEM analysis showed the alloys consisted of dendritic microstructure and C14 colonies. The amount of C14 phase increases when the amount of (FeV) decreases in these alloys. Concerning the hydrogen storage, the best results were obtained for the TiCr 1.2 (FeV) 0.4 alloy, which achieved 2.79 mass% of hydrogen storage capacity and 1.36 mass% of reversible hydrogen storage capacity

  17. Effect of heat treatments on precipitate microstructure and mechanical properties of CuCrZr alloy

    OpenAIRE

    Singh, B.N; Edwards, D.J.; Tähtinen, S.

    2004-01-01

    A number of specimens of CuCrZr alloy was prime aged and then overaged at 600oC for 1, 2 and 4 hours and for 4 hours at 700 and 850oC. After different heat treatments, both the precipitate microstructure and mechanical properties were characterized.Mechanical properties were determined at 50 and 300oC. Some selected specimens in the prime aged as well as overaged conditions were irradiated in the BR-2 reactor at Mol at 60 and 300oC to a displacement dose level of ~0.3 dpa. Irradiated specimen...

  18. Selective Flow-Injection Quantification of Ultra-trace Amounts of Cr(VI) via On-line Complexation and Preconcentration with APDC Followed by Determination by Electrothermal Atomic Absorption Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Hansen, Elo Harald

    1998-01-01

    A rapid, sensitive and selective time-based flow injection (FI) preconcentration procedure is described for the determination of ultra-trace amounts of Cr(VI) via on-line reaction with ammonium pyrrolidine dithiocarbamate (APDC) and formation of the Cr(VI)-PDC complex. The preconcentration...... to direct introduction of 55 mu l samples, yielding a detection limit (3 sigma) of 4.2 ng l(-1). The sample frequency was 21.2 samples per hour. The proposed method was evaluated by analyzing drinking water, a NIST Cr(VI)-reference material and synthetic sea water. A major contribution to successful...

  19. Improved wavelengths for the 1s2s3S1-1s2p3P0,2 transitions in helium-like Si12+

    International Nuclear Information System (INIS)

    Armour, I.A.; Myers, E.G.; Silver, J.D.; Traebert, E.; Oxford Univ.

    1979-01-01

    The wavelengths of the 1s2s 3 S 1 -1s2p 3 P 0 , 2 transitions in He-like Si 12+ have been remaesured to be 87.86 +- 0.01 nm and 81.48 +- 0.01 nm. The use of Rydberg lines for the calibration of fast beam spectra is discussed. (orig.)

  20. Spectral Analysis of CO2 Corrosion Product Scales on 13Cr Tubing Steel

    International Nuclear Information System (INIS)

    Guan-fa, Lin; Zhen-quan, Bai; Yao-rong, Feng; Xun-yuan, Xu

    2008-01-01

    CO 2 corrosion product scales formed on 13 Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the paper. The surface and cross-section profiles of the scales were observed by scanning electron microscopy (SEM), the chemical compositions of the scales were analyzed using energy dispersion analyzer of X-ray (EDAX), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) to confirm the corrosion mechanism of the 13 Cr steel in the simulated CO 2 corrosion environment. The results show that the corrosion scales are formed by the way of fashion corrosion, consist mainly of four elements, i.e. Fe, Cr, C and O, and with a double-layer structure, in which the surface layer is constituted of bulky and incompact crystals of FeCO 3 , and the inner layer is composed of compact fine FeCO 3 crystals and amorphous Cr(OH) 3 . Because of the characteristics of compactness and ionic permeating selectivity of the inner layer of the corrosion product scales, 13 Cr steel is more resistant in CO 2 corrosion environment

  1. Selected Properties And Tribological Wear Alloys Co-Cr-Mo And Co-Cr-Mo-W Used In Dental Prosthetics

    Directory of Open Access Journals (Sweden)

    Augustyn-Pieniążek J.

    2015-09-01

    Full Text Available The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.

  2. New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater

    International Nuclear Information System (INIS)

    Uygun, Murat; Feyzioğlu, Esra; Özçalışkan, Emir; Caka, Müşerref; Ergen, Aygen; Akgöl, Sinan; Denizli, Adil

    2013-01-01

    The purpose of this study was to prepare a novel ion-imprinted nanoparticle to remove Cr(VI) ions from waste water. For this, Cr(VI) ions were complexed with 2-methacryloylamido histidine (MAH) and then Cr(VI)-imprinted poly(HEMAH) nanoparticles were synthesized by surfactant-free emulsion polymerization technique. The templates, Cr(VI) ions, were removed from the nanoparticles using 0.1 M of HNO 3 solution. The specific surface area of the Cr(VI)-imprinted poly(HEMAH) nanoparticles was found to be 1,397.85 m 2 /g, and the particle size was calculated as 155.3 nm. These Cr(VI)-imprinted nanoparticles were used for the adsorption/desorption of Cr(VI) ions from its aqueous solutions. The effects of initial Cr(VI) concentration and medium pH on the Cr(VI) adsorption capacity were also studied. The maximum adsorbed amount of Cr(VI) on the imprinted nanoparticles was found to be 3,830.58 mg/g nanoparticle in pH 4.0. In order to investigate the selectivity of the imprinted nanoparticle, adsorption studies were repeated using Cr(III) ions. The selectivity results demonstrated that Cr(VI)-imprinted poly(HEMAH) nanoparticles showed high affinity for the Cr(VI) ions than Cr(III). The Cr(VI)-imprinted nanoparticles were used several times without decreasing their Cr(VI) adsorption capacities

  3. New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater

    Science.gov (United States)

    Uygun, Murat; Feyzioğlu, Esra; Özçalışkan, Emir; Caka, Müşerref; Ergen, Aygen; Akgöl, Sinan; Denizli, Adil

    2013-08-01

    The purpose of this study was to prepare a novel ion-imprinted nanoparticle to remove Cr(VI) ions from waste water. For this, Cr(VI) ions were complexed with 2-methacryloylamido histidine (MAH) and then Cr(VI)-imprinted poly(HEMAH) nanoparticles were synthesized by surfactant-free emulsion polymerization technique. The templates, Cr(VI) ions, were removed from the nanoparticles using 0.1 M of HNO3 solution. The specific surface area of the Cr(VI)-imprinted poly(HEMAH) nanoparticles was found to be 1,397.85 m2/g, and the particle size was calculated as 155.3 nm. These Cr(VI)-imprinted nanoparticles were used for the adsorption/desorption of Cr(VI) ions from its aqueous solutions. The effects of initial Cr(VI) concentration and medium pH on the Cr(VI) adsorption capacity were also studied. The maximum adsorbed amount of Cr(VI) on the imprinted nanoparticles was found to be 3,830.58 mg/g nanoparticle in pH 4.0. In order to investigate the selectivity of the imprinted nanoparticle, adsorption studies were repeated using Cr(III) ions. The selectivity results demonstrated that Cr(VI)-imprinted poly(HEMAH) nanoparticles showed high affinity for the Cr(VI) ions than Cr(III). The Cr(VI)-imprinted nanoparticles were used several times without decreasing their Cr(VI) adsorption capacities.

  4. New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Uygun, Murat, E-mail: muygun@adu.edu.tr [Adnan Menderes University, Kocarl Latin-Small-Letter-Dotless-I Vocational and Training School (Turkey); Feyzioglu, Esra; Oezcal Latin-Small-Letter-Dotless-I skan, Emir; Caka, Mueserref; Ergen, Aygen; Akgoel, Sinan [Ege University, Department of Biochemistry, Faculty of Science (Turkey); Denizli, Adil [Hacettepe University, Department of Chemistry, Faculty of Science (Turkey)

    2013-08-15

    The purpose of this study was to prepare a novel ion-imprinted nanoparticle to remove Cr(VI) ions from waste water. For this, Cr(VI) ions were complexed with 2-methacryloylamido histidine (MAH) and then Cr(VI)-imprinted poly(HEMAH) nanoparticles were synthesized by surfactant-free emulsion polymerization technique. The templates, Cr(VI) ions, were removed from the nanoparticles using 0.1 M of HNO{sub 3} solution. The specific surface area of the Cr(VI)-imprinted poly(HEMAH) nanoparticles was found to be 1,397.85 m{sup 2}/g, and the particle size was calculated as 155.3 nm. These Cr(VI)-imprinted nanoparticles were used for the adsorption/desorption of Cr(VI) ions from its aqueous solutions. The effects of initial Cr(VI) concentration and medium pH on the Cr(VI) adsorption capacity were also studied. The maximum adsorbed amount of Cr(VI) on the imprinted nanoparticles was found to be 3,830.58 mg/g nanoparticle in pH 4.0. In order to investigate the selectivity of the imprinted nanoparticle, adsorption studies were repeated using Cr(III) ions. The selectivity results demonstrated that Cr(VI)-imprinted poly(HEMAH) nanoparticles showed high affinity for the Cr(VI) ions than Cr(III). The Cr(VI)-imprinted nanoparticles were used several times without decreasing their Cr(VI) adsorption capacities.

  5. Crystal structure and magnetic properties of the Cr-doped spiral antiferromagnet BiMnFe{sub 2}O{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Batuk, Dmitry, E-mail: Dmitry.batuk@ua.ac.be [Electron Microscopy for Materials Research (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020, Antwerp (Belgium); De Dobbelaere, Christopher [Inorganic and Physical Chemistry Group, Hasselt University, Institute for Materials Research, Agoralaan Building D, B-3590, Diepenbeek (Belgium); Tsirlin, Alexander A. [National Institute of Chemical Physics and Biophysics, 12618, Tallinn (Estonia); Abakumov, Artem M. [Electron Microscopy for Materials Research (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020, Antwerp (Belgium); Hardy, An; Van Bael, Marlies K. [Inorganic and Physical Chemistry Group, Hasselt University, Institute for Materials Research, Agoralaan Building D, B-3590, Diepenbeek (Belgium); IMEC vzw, Division IMOMEC, Agoralaan Building D, B-3590, Diepenbeek (Belgium); Greenblatt, Martha [Department of Chemistry and Chemical Biology, Rutgers, State University of New Jersey, 610 Taylor Road, Piscataway, New Jersey, 08854-8087 (United States); Hadermann, Joke [Electron Microscopy for Materials Research (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020, Antwerp (Belgium)

    2013-09-01

    Graphical abstract: - Highlights: • The substitution of Cr for Mn in BiMnFe{sub 2}O{sub 6} is possible by the solution–gel method. • The BiCr{sub x}Mn{sub 1−x}Fe{sub 2}O{sub 6} solid solution is obtained for the x values up to 0.3. • Increasing Cr content lowers the temperature of the antiferromagnetic ordering. - Abstract: We report the Cr{sup 3+} for Mn{sup 3+} substitution in the BiMnFe{sub 2}O{sub 6} structure. The BiCr{sub x}Mn{sub 1−x}Fe{sub 2}O{sub 6} solid solution is obtained by the solution–gel synthesis technique for the x values up to 0.3. The crystal structure investigation using a combination of X-ray powder diffraction and transmission electron microscopy demonstrates that the compounds retain the parent BiMnFe{sub 2}O{sub 6} structure (for x = 0.3, a = 5.02010(6)Å, b = 7.06594(7)Å, c = 12.6174(1)Å, S.G. Pbcm, R{sub I} = 0.036, R{sub P} = 0.011) with only a slight decrease in the cell parameters associated with the Cr{sup 3+} for Mn{sup 3+} substitution. Magnetic susceptibility measurements suggest strong similarities in the magnetic behavior of BiCr{sub x}Mn{sub 1−x}Fe{sub 2}O{sub 6} (x = 0.2; 0.3) and parent BiMnFe{sub 2}O{sub 6}. Only T{sub N} slightly decreases upon Cr doping that indicates a very subtle influence of Cr{sup 3+} cations on the magnetic properties at the available substitution rates.

  6. Characterization of transparent superconductivity Fe-doped CuCrO{sub 2} delafossite oxide

    Energy Technology Data Exchange (ETDEWEB)

    Taddee, Chutirat [Materials Science and Nanotechnology Program, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Kamwanna, Teerasak, E-mail: teekam@kku.ac.th [Department of Physics, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Nanotec-KKU Center of Excellence on Advanced Nanomaterials for Energy Production and Storage, Khon Kaen 40002 (Thailand); Integrated Nanotechnology Research Center (INRC), Khon Kaen University, Khon Kaen 40002 (Thailand); Amornkitbamrung, Vittaya [Department of Physics, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Nanotec-KKU Center of Excellence on Advanced Nanomaterials for Energy Production and Storage, Khon Kaen 40002 (Thailand); Integrated Nanotechnology Research Center (INRC), Khon Kaen University, Khon Kaen 40002 (Thailand)

    2016-09-01

    Graphical abstract: - Highlights: • Effect of Fe substitution on the physical properties in CuCrO{sub 2} is studied. • The substitution of Cr{sup 3+} by Fe{sup 3+} produces a mixed effect on the magnetic properties. • CuCr{sub 1−x}Fe{sub x}O{sub 2} delafossite oxides show transparent superconductivity. - Abstract: Delafossite CuCr{sub 1−x}Fe{sub x}O{sub 2} (0.0 ≤ x ≤ 0.15) semiconductors were synthesized using a self-combustion urea nitrate process. The effects of Fe concentration on its microstructural, optical, magnetic, and electrical properties were investigated. X-ray diffraction (XRD) analysis results revealed the delafossite structure in all the samples. The lattice spacing of CuCr{sub 1−x}Fe{sub x}O{sub 2} slightly increased with increasing substitution of Fe at the Cr sites. The optical properties measured at room temperature using UV–visible spectroscopy showed a weak absorbability in the visible light and near IR regions. The corresponding direct optical band gap was about 3.61 eV, exhibiting transparency in the visible region. The magnetic hysteresis loop measurements showed that the Fe-doped CuCrO{sub 2} samples exhibited ferromagnetic behavior at room temperature. This indicated that the substitution of Fe{sup 3+} for Cr{sup 3+} produced a mixed effect on the magnetic properties of CuCrO{sub 2} delafossite oxide. The temperature dependent resistivity measurements clearly revealed the presence of superconductivity in the CuCr{sub 1−x}Fe{sub x}O{sub 2} with a superconducting transition up to 118 K.

  7. Separation of Cr(III) from Cr(VI) by Triton X-100 cerium(IV) phosphate as a surface active ion exchanger

    International Nuclear Information System (INIS)

    El-Azony, K.M.; Ismail Aydia, M.; El-Mohty, A.A.

    2011-01-01

    Triton X-100 cerium(IV) phosphate (TX-100CeP) was synthesized and characterized by using IR, X-ray, TGA/DT and the elemental analysis. The chemical stability of TX-100CeP versus the different concentrations of HCl acid was studied before and after its exposure to the radiation dose (30 K Gray). The effect of HCl concentration on separation of Cr(III) from Cr(VI) by using TX-100CeP as surface active ion exchanger was also studied. A novel method was achieved for the quantifying of Cr(III) and Cr(VI) ions by using the high-performance liquid chromatography (HPLC) at wavelength 650 nm, a stationary phase consists of reversed phase column (Nucleosil phenyl column; 250 x 4.6 mm, 5 μm), and a mobile phase consists of 0.001 M di-(2-ethylhexyl) phosphoric acid (DEHPA) in methanol:water (70:30 v/v). The retention times were 7.0 and 8.5 min, for the Cr(III) and Cr(VI), respectively. The exchange capacity of Cr(III) was quantified (2.1 meq/g) onto the TX-100CeP. (author)

  8. Mechanical and microstructural behavior of oxide dispersion strengthened 8Cr-2W and 8Cr-1W steels during creep deformation

    Energy Technology Data Exchange (ETDEWEB)

    Shinozuka, K.; Tamura, M.; Esaka, H. [National Defense Academy, Dept. MS and E, Kanagawa (Japan); Shiba, K.; Nakamura, K. [Japan Atomic Energy Agency, Tokai-mura, Naga-gun, Ibaraki-ken (Japan)

    2007-07-01

    Full text of publication follows: Oxide dispersion strengthened (ODS) steel is a promising candidate for fusion reactor material because of excellent mechanical properties. However, the ODS steel exhibits some defects, such as mechanical anisotropy and little elongation . To reveal details of these defects, we investigated correlations between mechanical and microstructural behavior of ODS ferritic steels during creep deformation at high temperature. The materials used in this study are two kinds of hot rolled ODS steels: Fe-8Cr-2W-0.2V-0.1Ta-0.2Ti-0.4Y{sub 2}O{sub 3} (J1) and Fe-8Cr-1W-0.2Ti-0.4Y{sub 2}O{sub 3} (J2). Creep tests was carried out on specimens sampling along both the rolling direction and the cross direction at 670, 700 and 730 deg. C. Microstructural analyses were made on the normalized and tempered condition by using OM, SEM, TEM and XRD. Creep ruptured and interrupted specimens were also investigated. Both J1 and J2 existed two phases, namely martensite and {delta}-ferrite which was elongated in the rolling direction. Y-Ti complex oxide particles were finely dispersed in martensite and {delta}- ferrite phases. Results of creep tests indicated that the time-to-rupture of specimens of J1 were much longer than J2, and the time-to-rupture of specimens sampling along the rolling direction were longer than cross direction. Accordingly, J1 sampling along hot rolling direction was the strongest, for instance, the time-to-rupture was 11400 h at 700 deg. C and 162 MPa. All specimens indicated that elongation was less than 1.3 % and the rupture occurred at steady state creep region from creep curves. Internal cracks were propagated in martensite phase along elongated {delta}-ferrite phase in the direction of hot rolling. On the other hand, {delta}-ferrite phases seemed to prevent combining cracks. These results suggest that elongated {delta}-ferrite and internal clacks in martensite strongly affect on the anisotropy and little elongation of creep. (authors)

  9. Electron concentration and phase stability in NbCr2-based Laves phase alloys

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J.H.; Liaw, P.K. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Materials Science and Engineering; Liu, C.T. [Oak Ridge National Lab., TN (United States). Metals and Ceramics Div.

    1997-05-12

    Phase stability in NbCr{sub 2}-based transition-metal Laves phases was studied, based on the data reported for binary X-Cr, Nb-X, and ternary Nb-Cr-X phase diagrams. It was shown that when the atomic size ratios are kept identical, the average electron concentration factor, e/a, is the dominating factor in controlling the phase stability of NbCr{sub 2}-based transition-metal Laves phases. The e/a ratios for different Laves polytypes were determined as followed: with e/a < 5.76, the C15 structure is stabilized; at an e/a range of 5.88--7.53, the C14 structure is stabilized; with e/a > 7.65, the C15 structure is stabilized again. A further increase in the electron concentration factor (e/a > 8) leads to the disordering of the alloy. The electron concentration effect on the phase stability of Mg-based Laves phases and transition-metal A{sub 3}B intermetallic compounds is also reviewed and compared with the present observations in transition-metal Laves phases. In order to verify the e/a/phase stability relationship experimentally, additions of Cu (with e/a = 11) were selected to replace Cr in the NbCr{sub 2} Laves phase. Experimental results for the ternary Nb-Cr-Cu system are reported and discussed in terms of the correlation between the e/a ratio and phase stability in NbCr{sub 2}-based Laves phases. A new phase was found, which has an average composition of Nb-47Cr-3Cu. Within the solubility limit, the electron concentration and phase stability relationship is obeyed in the Nb-Cr-Cu system.

  10. Evaluation of ferritic alloy Fe-2 1/4Cr-1Mo after neutron irradiation: Microstructural development

    International Nuclear Information System (INIS)

    Gelles, D.S.

    1986-10-01

    As part of a program to provide a data base on the bainitic alloy Fe-2-1/4-1Mo for fusion energy applications, microstructural examinations are reported for nine specimen conditions for 2-1/4Cr-1Mo steel which had been irradiated by fast neutrons over the temperature range 390 to 510 0 C. Void swelling is found following irradiation at 400 0 C to 480 0 C. Concurrently dislocation structure and precipitation developed. Peak void swelling, void density, dislocation density and precipitate number density formed at the lowest temperature, approximately 400 0 C, whereas mean void size, and mean precipitate size increased with increasing irradiation temperature. The examination results are used to provide interpretation of in-reactor creep, density change and post irradiation tensile behavior

  11. Mechanical and physical properties of 2 1/4 Cr--1 Mo steel in support of CRBRP steam generator design

    International Nuclear Information System (INIS)

    Brinkman, C.R.; Williams, R.K.; Klueh, R.L.; Hebble, T.L.

    1975-01-01

    Mechanical and physical property tests on annealed 2 1 / 4 Cr-1 Mo steel were conducted in an effort to define behavior in support of the design of the Clinch River Breeder Reactor Plant (CRBRP) steam generator design. Interim empirical expressions and/or data are reported from the results of tensile, creep, fatigue, creep-fatigue, subcritical crack growth, thermal conductivity, thermal diffusivity, and thermal expansion tests and analysis. These expressions cover behavior, where appropriate, over a range of temperatures from 25 to as high as 700 0 C. Comparisons between thermal conductivity and diffusivity values and those found in the American Society of Mechanical Engineers (ASME) Code indicated that the new values were significantly higher than those found presently in the Code. The importance and complexity of obtaining valid mechanical and physical properties for the Clinch River Breeder Reactor Plant (CRBRP) steam generator are discussed. (U.S.)

  12. Modification of chemical, optical and structural properties of Bayfol CR-6-2 using gamma and neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shehata, Mohamed M.; Radwan, Samh I.; Hassan, Amin [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Centre; Waly, Sayed A. [Atomic Energy Authority, Cairo (Egypt). Second Research Reactor; Badawy, Zaynab M. [Atomic Energy Authority, Cairo (Egypt). Experimental Nuclear Physics Dept.

    2016-08-01

    The effects of gamma and neutron irradiations on the chemical, optical and structural properties of Bayfol CR-6-2 were investigated. The samples were irradiated by γ-rays from a {sup 60}Co source at various doses ranging between 16 and 900 kGy at room temperature in atmospheric air. For neutrons, an Am-Be neutron facility was used for the sample irradiation in thermal mode which had an activity of 185 GBq. Samples were irradiated with different doses of neutrons ranging from 15.7 to 564.2 mGy. The changes induced were analyzed using UV-Vis and Fourier transform infrared (FTIR) spectrometry. The results demonstrated an occurrence of oxidative degradation, resulting in the formation of carbonyl groups at 1700 cm{sup -1}. Simultaneous thermo-gravimetric investigation (TGA) has been performed on the samples of 0.3 mm thickness. The results obtained indicate that cross-linking predominates at small neutron doses and main chain scission happens at higher doses.

  13. Application of a Novel Dose-Uncertainty Model for Dose-Uncertainty Analysis in Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Jin Hosang; Palta, Jatinder R.; Kim, You-Hyun; Kim, Siyong

    2010-01-01

    Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT). Methods and Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty-based plan evaluation tools were introduced: confidence-weighted dose-volume histogram, confidence-weighted dose distribution, and dose-uncertainty-volume histogram. Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose. Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans.

  14. Seguridad de la terapia de interferón alfa 2b recombinante más ribavirina en la hepatitis crónica C

    OpenAIRE

    Sánchez Rodríguez, Yoan Antonio; Arús Soler, Enrique; López Saura, Pedro; Nodarse Cuní, Hugo

    2011-01-01

    INTRODUCCIÓN: la hepatitis crónica C ha adquirido rango de pandemia. El virus de la hepatitis C se ha convertido en la causa principal de hepatitis crónica, cirrosis hepática, hepatocarcinoma, y trasplante de hígado a nivel mundial. OBJETIVO: identificar los efectos adversos asociados a la terapia combinada interferón alfa 2b recombinante más ribavirina durante la evolución del tratamiento y hasta 8 semanas después de finalizado, así como los principales efectos asociados a salidas temporales...

  15. Influence of Selective Laser Melting Processing Parameters of Co-Cr-W Powders on the Roughness of Exterior Surfaces

    Science.gov (United States)

    Baciu, M. A.; Baciu, E. R.; Bejinariu, C.; Toma, S. L.; Danila, A.; Baciu, C.

    2018-06-01

    Selective Laser Melting (SLM) represents an Additive Manufacturing method widely used in medical practice, mainly in dental medicine. The powder of 59% Co, 25% Cr, 2.5% W alloy (Starbond CoS Powder 55, S&S Scheftner C, Germany) was processed (SLM) on a Realizer SLM 50 device (SLM Solution, Germany). After laser processing and simple sanding with Al2O3 or two-phase sanding (Al2O3 and glass balls), measurements of surface roughness were conducted. This paper presents the influences exercised by laser power (P = 60 W, 80 W and 100 W), the scanning speed (vscan = 333 mm/s, 500 mm/s and 1000 mm/s) and exposure time (te = 20 µs, 40 µs and 60 µs) on the roughness of surfaces obtained by SLM processing. Based on the experimental results obtained for roughness (Ra), some recommendations regarding the choice of favorable combinations among the values of technological parameters under study in order to obtain the surface quality necessary for subsequent applications of the processed parts (SLM) have been made.

  16. Application of double-spike isotope dilution for the accurate determination of Cr(III), Cr(VI) and total Cr in yeast.

    Science.gov (United States)

    Yang, Lu; Ciceri, Elena; Mester, Zoltán; Sturgeon, Ralph E

    2006-11-01

    A method is presented for the simultaneous determination of Cr(III) and Cr(VI) in yeast using species-specific double-spike isotope dilution (SSDSID) with anion-exchange liquid chromatography (LC) separation and sector field inductively coupled plasma mass spectrometric (SF-ICP-MS) detection. Total Cr is quantitated using ID SF-ICP-MS. Samples were digested on a hot plate at 95+/-2 degrees C for 6 h in an alkaline solution of 0.5 M NaOH and 0.28 M Na2CO3 for the determination of Cr(III) and Cr(VI), whereas microwave-assisted decomposition with HNO3 and H2O2 was used for the determination of total Cr. Concentrations of 2,014+/-16, 1,952+/-103 and 76+/-48 mg kg-1 (one standard deviation, n=4, 3, 3), respectively were obtained for total Cr, Cr(III) and Cr(VI) in the yeast sample. Significant oxidation of Cr(III) to Cr(VI) (24.2+/-7.6% Cr(III) oxidized, n=3) and reduction of Cr(VI) to Cr(III) (37.6+/-6.5% Cr(VI) reduced, n=3) occurred during alkaline extraction and subsequent chromatographic separation at pH 7. Despite this significant bidirectional redox transformation, quantitative recoveries for both Cr(III) and Cr(VI) were achieved using the SSDSID method. In addition, mass balance between total Cr and the sum of Cr(III) and Cr(VI) concentrations was achieved. Method detection limits of 0.3, 2 and 30 mg kg-1 were obtained for total Cr, Cr(VI) and Cr(III), respectively, based on a 0.2-g sub-sample.

  17. Humidity sensitive electrical responce of K2CrO4 doped ZnCr2O4 ceramic sensors

    International Nuclear Information System (INIS)

    Kavasoglu, N.

    2005-01-01

    The effects of the addition of various percentages of potassium chromate as a sintering aid on the response to air moisture of ZnCr 2 O 4 ceramic body along with its crystalline structure and surface morphology were studied. The fired ceramic body, which proved to be mainly constructed from about 1μm sized ZnCr 2 O 4 spinel grains, was porous. The humidity sensing behaviour of the sensors reveals that the electrical conduction is due mainly to protonic and is controlled through the thin layers of water, adsorbed on the surface of the grains, with charge transfer to the electrodes. Only the material containing 20% K 2 CrO 4 in ZnCr 2 O 4 exhibited an exponential behaviour to humidity, which shows about three orders change in the d.c. resistance over the relative humidity in the range between 25 and 90%. The addition of CuO resulted in an increase in the conductivity but had a deleterious effect on the humidity. Based on a.c. impedance measurements, an equivalent circuit associated with a net work of RC parallel circuit in series with constant phase elements (CPEs) has been suggested. It can be therefore assumed that such equivalent circuit model of the sensor under moderate moist condition indicates the charge transport processes mediated by proton hopping and diffusion. A homemade prototype of such a humidity sensor has also been successfully demonstrated in door

  18. Ion irradiation effects on high purity bcc Fe and model FeCr alloys

    International Nuclear Information System (INIS)

    Bhattacharya, Arunodaya

    2014-01-01

    FeCr binary alloys are a simple representative of the reduced activation ferritic/martensitic (F-M) steels, which are currently the most promising candidates as structural materials for the sodium cooled fast reactors (SFR) and future fusion systems. However, the impact of Cr on the evolution of the irradiated microstructure in these materials is not well understood in these materials. Moreover, particularly for fusion applications, the radiation damage scenario is expected to be complicated further by the presence of large quantities of He produced by the nuclear transmutation (∼ 10 appm He/dpa). Within this context, an elaborate ion irradiation study was performed at 500 C on a wide variety of high purity FeCr alloys (with Cr content ranging from ∼ 3 wt.% to 14 wt.%) and a bcc Fe, to probe in detail the influence of Cr and He on the evolution of microstructure. The irradiations were performed using Fe self-ions, in single beam mode and in dual beam mode (damage by Fe ions and co-implantation of He), to separate ballistic damage effect from the impact of simultaneous He injection. Three different dose ranges were studied: high dose (157 dpa, 17 appm He/dpa for the dual beam case), intermediate dose (45 dpa, 57 appm He/dpa for dual beam case) and in-situ low dose (0.33 dpa, 3030 appm He/dpa for the dual beam case). The experiments were performed at the JANNuS triple beam facility and dual beam in situ irradiation facility at CEA-Saclay and CSNSM, Orsay respectively. The microstructure was principally characterized by conventional TEM, APT and EDS in STEM mode. The main results are as follows: 1) A comparison of the cavity microstructure in high dose irradiated Fe revealed strong swelling reduction by the addition of He. It was achieved by a drastic reduction in cavity sizes and an increased number density. This behaviour was observed all along the damage depth, up to the damage peak. 2) Cavity microstructure was also studied in the dual beam high dose

  19. Performance evaluation of domestic prototype dose area product meter SFT-1

    International Nuclear Information System (INIS)

    Lee, Ho Sun; Han, Seong Gyu; Roh, Young Roh; Lim, Hyun Jong; Kim, Jung Min; Kim, Jong Uk; Chae, Hyun Sik; Yoon, Yong Su

    2016-01-01

    The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R and BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product. Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatabilit y coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria

  20. The calculation of 131I dose in second treatment for Graves' disease and the selection of patients

    International Nuclear Information System (INIS)

    Yang Jisheng; Wang Qiang; Hu Mingzao; Zuo Lei; Peng Xiaoyan

    2001-01-01

    Objective: To improve the method of 131 I dose calculation in second treatment for Graves' disease (GD) and to make a criterion for selection of patients. Methods: From 87 GD patients not recovered more than half a year after 131 I treatment, authors selected 41 cases (group A) whose thyroid weight were ≥30 g and gave them second 131 I treatment. The absorbed dose (d 2 ) of 131 I was calculated by the formula we designed: (m 1 /m 2 ):d 1 =(m 2 /m 3 ): d 2 ; i.e. d 2 (Gy) = d 1 m 2 2 /m 1 m 3 . The total dose (D) was calculated by the classical formula: D(37 KBq or μ Ci)= d 2 x 8 x m 2 (g)/1.6 x max. uptake % of 131 I x T 1/2eff (days). m 1 and m 2 was the thyroid weight before and after the first 131 I treatment respectively, m 3 was the pre-estimated thyroid weight after the second treatment, d 1 was the unit dose of the first treatment. Results were compared with 97 patients (group B) who had received second 131 I treatment before using this calculation method. The resting 46 cases (group C) whose thyroid weight were 131 I treatment of group A was 73.2% (30/41 cases), it was remarkably higher than that of group B (19.6%), but the early-permanent hypothyroidism rate was lower in group A. The recovery rate of group C was 91.3% (42/46 case) in two years (averaged 8.8 months). Conclusion: The calculating method can make the dose of second 131 I treatment for GD relatively optimal. Thyroid weight ≥30 g can be used as the main criterion for selection of patients 131 I treatment. Patients whose thyroid weight 131 I treatment and the therapeutic effect was poor

  1. Does selective pleural irradiation of malignant pleural mesothelioma allow radiation dose escalation. A planning study

    Energy Technology Data Exchange (ETDEWEB)

    Botticella, A.; Defraene, G. [KU Leuven - University of Leuven, Department of Oncology, Experimental Radiation Oncology, Leuven (Belgium); Nackaerts, K. [KU Leuven - University of Leuven, University Hospitals Leuven, Department of Respiratory Medicine, Leuven (Belgium); Deroose, C. [KU Leuven - University of Leuven, University Hospitals Leuven, Nuclear Medicine, Leuven (Belgium); Coolen, J. [KU Leuven - University of Leuven, University Hospitals Leuven, Radiology Department, Leuven (Belgium); Nafteux, P. [University Hospitals Leuven, Department of Thoracic Surgery, Leuven (Belgium); Vanstraelen, B. [University Hospitals Leuven, Department of Radiation Oncology, Leuven (Belgium); Joosten, S.; Michiels, L.A.W. [Fontys University of Applied Science, Institute Paramedical Studies, Medical Imaging and Radiotherapeutic Techniques, Eindhoven (Netherlands); Peeters, S. [KU Leuven - University of Leuven, Department of Oncology, Experimental Radiation Oncology, Leuven (Belgium); University Hospitals Leuven, Department of Radiation Oncology, Leuven (Belgium); Ruysscher, D. de [KU Leuven - University of Leuven, Department of Oncology, Experimental Radiation Oncology, Leuven (Belgium); Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Department of Radiation Oncology (MAASTRO Clinic), Maastricht (Netherlands)

    2017-04-15

    After lung-sparing radiotherapy for malignant pleural mesothelioma (MPM), local failure at sites of previous gross disease represents the dominant form of failure. Our aim is to investigate if selective irradiation of the gross pleural disease only can allow dose escalation. In all, 12 consecutive stage I-IV MPM patients (6 left-sided and 6 right-sided) were retrospectively identified and included. A magnetic resonance imaging-based pleural gross tumor volume (GTV) was contoured. Two sets of planning target volumes (PTV) were generated for each patient: (1) a ''selective'' PTV (S-PTV), originating from a 5-mm isotropic expansion from the GTV and (2) an ''elective'' PTV (E-PTV), originating from a 5-mm isotropic expansion from the whole ipsilateral pleural space. Two sets of volumetric modulated arc therapy (VMAT) treatment plans were generated: a ''selective'' pleural irradiation plan (SPI plan) and an ''elective'' pleural irradiation plan (EPI plan, planned with a simultaneous integrated boost technique [SIB]). In the SPI plans, the average median dose to the S-PTV was 53.6 Gy (range 41-63.6 Gy). In 4 of 12 patients, it was possible to escalate the dose to the S-PTV to >58 Gy. In the EPI plans, the average median doses to the E-PTV and to the S-PTV were 48.6 Gy (range 38.5-58.7) and 49 Gy (range 38.6-59.5 Gy), respectively. No significant dose escalation was achievable. The omission of the elective irradiation of the whole ipsilateral pleural space allowed dose escalation from 49 Gy to more than 58 Gy in 4 of 12 chemonaive MPM patients. This strategy may form the basis for nonsurgical radical combined modality treatment of MPM. (orig.) [German] Beim malignen Pleuramesotheliom (MPM) ist nach lungenschonender Radiotherapie das lokale Scheitern an Stellen eines frueheren, sichtbaren Tumors die dominierende Form des Scheiterns. Unser Ziel ist es, zu untersuchen, ob die selektive

  2. Absorbed dose profiles for 32P, 90Y, 188Re, 177Lu, 51Cr, 153Sm and 169Er: radionuclides used in radiosynoviortheses treatment

    International Nuclear Information System (INIS)

    Torres, M.; Ayra, E.; Albuerne, O.; Delgado, M.

    2008-01-01

    The remarkable advances in the design and synthesis of radiopharmaceuticals has created the opportunity of generating new agents for the treatment of radiosynoviortheses (RSV) which exhibit a minimum leakage from the synovial joint reducing, this way, the non desired absorbed doses to non target organs such as liver, spleen, kidney. Nowadays, the variety of beta emitters used in RSV ranges between 0.34 MeV - 0.33 mm penetration in tissue ( 169 Er) and 2.27 MeV - 3.6 mm penetration in tissue ( 90 Y). The half life of these isotopes goes from 2.3 hours ( 165 Dy) to 27.8 days ( 51 Cr). The selection criterion on which radionuclide should be used, in modern clinics, depends on which joints are to be treated. Thus, the smaller the joint, the lowest should be the energy of the beta emitted and the penetration in soft tissue of these particles. This leads to the use of fixed radionuclides and doses for each kind of joint. In the Isotopes Centre, we've been carrying on studies for the development of radiopharmaceuticals for the radiosynoviortheses treatment and focused our attention in the following radionuclides: 32 P, 90 Y, 188 Re, 177 Lu, 51 Cr, 153 Sm and 169 Er. The main objective of this paper was to obtain the absorbed dose profiles for radionuclides of frequent or potential use in radiosynoviortheses. These profiles reveal the absorbed dose imparted per unit activity of injected radionuclide (Gy/h*MBq) in the synovial membrane and the articular cartilage. The researched radionuclides were those previously mentioned. Also were calculated the therapeutic range of each radionuclides in synovial tissue. The therapeutic range is defined as the deepness at which the absorbed dose equals the 10 % of the maximum dose deposited in the synovial surface. This range determines the synovial thickness that can be sufficiently irradiated and thus successfully treated. The synovial membrane model consisted on a cylinder with the source uniformly distributed in its volume. This

  3. Structural, magnetic and magnetocaloric properties of La{sub 0.7}Ca{sub 0.2}Sr{sub 0.1}Mn{sub 1−x}Cr{sub x}O{sub 3} compounds with x = 0, 0.05 and 0.1

    Energy Technology Data Exchange (ETDEWEB)

    Dhahri, Ah., E-mail: dhahri.ahmad@outlook.fr [Laboratoire de Physique Appliquée, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Jemmali, M. [Laboratoire des Sciences des Matériaux et de l’Environnement, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Taibi, K. [Département SDM, FGMGP/USTHB, 16311 (Algeria); Dhahri, E. [Laboratoire de Physique Appliquée, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Hlil, E.K. [Institut Néel, CNRS et Université J. Fourier, BP 166, 38042 Grenoble (France)

    2015-01-05

    Highlights: • The samples crystallize in the rhombohedral structure with the R3{sup ¯}c space group. • Enhancement of T{sub C} for the rhombohedral samples. • The relative cooling power increases with Cr-doping. • All samples exhibit a large magnetocaloric effect. • High values of the magnetoresistance in all samples. - Abstract: Structural, magnetic and magnetocaloric properties of La{sub 0.7}Sr{sub 0.1}Ca{sub 0.2}Mn{sub 1−x}Cr{sub x}O{sub 3} compounds with x = 0, 0.05 and 0.1 have been investigated to shed light on Cr-doping influence. X-ray diffraction studies show that all samples crystallize in the rhombohedral symmetry with R3{sup ¯}c space group. Rietveld refinement structure shows that the insertion of Cr in Mn network modifies the structural parameters such as the volume, Mn–O–Mn angles and the Mn–O bond length. The substitution of Mn by Cr decreases the 2p-3d hybridization between O and Mn ions, reduces the bandwidth and increases the electron–phonon coupling. The investigation of magnetic and magnetocaloric properties reveals that the samples exhibit a paramagnetic(PM)–ferromagnetic (FM) transition with decreasing Curie temperature (T{sub C}) from 294 K to 255 K when Cr doping level increases. The magnetic entropy change (ΔS{sub M}{sup max}) also decreases from 6.20 J kg{sup −1} K{sup −1} for x = 0 to3.80 J kg{sup −1} K{sup −1} for x = 0.1, while the relative cooling power (RCP) increases from 234.5 to 240 J kg{sup −1}, respectively, under a magnetic field of 5 T. These outcomes suggest that Mn-site Cr doping inhibits the enhancement of the magnetocaloric effect in some perovskite manganites. This is explained by the weakening of the ferromagnetic double-exchange interaction between Mn{sup 3+} and Mn{sup 4+} ions.

  4. Structure and magnetic properties of Co{sub 2}(Cr{sub 1−x}Fe{sub x})Al, (0 ≤ x ≤ 1) Heusler alloys prepared by mechanical alloying

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Yogesh, E-mail: 123209001_yogesh@manit.ac.in [Department of Materials Science & Metallurgical Engineering, Ceramic & Powder Metallurgy Laboratory, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh 462003 (India); Vajpai, Sanjay Kumar, E-mail: vajpaisk@gmail.com [Department of Materials Science & Metallurgical Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh 462003 (India); Srivastava, Sanjay, E-mail: s.srivastava.msme@gmail.com [Department of Materials Science & Metallurgical Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh 462003 (India)

    2017-07-01

    Highlights: • A series of nanocrystalline Co{sub 2}(Cr{sub 1−x}Fe{sub x})Al Heusler alloy by powder metallurgy. • Effect of substitution of Fe for Cr on the microstructure and magnetic properties. • Increasing amounts of B2 type disordered structure with increasing Fe content. • Enhanced Ms, Mr, Hc, and Tc with increasing Fe content. • Relative magnetic anisotropy decreased with increasing Fe content. - Abstract: In the present study, a series of nanocrystalline Co{sub 2}(Cr{sub 1−x}Fe{sub x})Al Heusler alloy powders were successfully prepared by high energy ball milling and the effect of substitution of Fe for Cr on the microstructure and magnetic properties was investigated in detail. The Co{sub 2}CrAl alloy powder consisted of only A2 type disordered structure whereas the substitution of Cr by Fe led to the appearance of increasing amounts of B2 type disordered structure along with A2 type structure. All the Co{sub 2}(Cr{sub 1−x}Fe{sub x})Al Heusler alloy powders demonstrated high spontaneous magnetization together with a very small hysteresis losses. The saturation magnetization, remanence, coercivity, and Curie temperature increased with increasing Fe content. The increasing magnetization with increasing Fe content was attributed to the replacement of antiferromagnetic Cr by strongly ferromagnetic Fe and an increasing amounts of relatively more ordered, atomically as well as ferromagnetically, B2 structure as compared to that of A2 phase. The increment in remanence and coercivity with increasing Fe content were associated with the variation in microstructural characteristics, such as grain size, lattice defects, and the presence of small amounts of magnetic/nonmagnetic secondary phases. The increment in Curie temperature with increasing Fe content was attributed to the enhancement of d-d exchange interaction due to the possible occupancy of vacant sites by Fe atoms. All the Heusler alloys indicated extremely low magnetic anisotropy and the

  5. Phase formation in Na2MoO4 - MgMoO4 - Cr2(MoO4)3 system

    International Nuclear Information System (INIS)

    Kotova, I.Yu.; Kozhevnikova, N.M.

    1998-01-01

    Interaction within Na 2 MoO 4 - MgMoO 4 - Cr 2 (MoO 4 ) 3 ternary system is studied by X ray phase and DTA methods. State diagram of NaCr(MoO 4 ) 2 - MgMoO 4 section is plotted. Production of ternary molybdates of Na 1-x Mg 1-x Cr 1+x (MoO 4 ) 3 , where 0 ≤ x ≤ 0.3, and NaMg 3 Cr(MoO 4 ) 5 composition is ascertained [ru

  6. Exposure dose estimation of nursing personnel and visitors following "1"2"5I brachytherapy

    International Nuclear Information System (INIS)

    Nakazato, Kazuhisa; Kikuchi, Hirosumi; Hotta, Harumi; Nishizawa, Kunihide

    2007-01-01

    An automated access management system to the controlled sickrooms for "1"2"5I brachytherapy was developed. The system consists of access control and video surveillance units. The patients implanted "1"2"5I seeds were isolated for about 20 h after surgery in the controlled sickrooms. The maximum doses and dose rates of the nurses and visitors were estimated by using the legal upper limit activity of 1,300 MBq, the measured longest staying time, and the shortest distance between the patients and individuals. Video analysis revealed activities of the nurses, patients, and visitors in the controlled sickroom, and relationships between the access frequency and staying time. The nurses' measured doses ranged from 1 to 3 μSv, and averaged 1.6 μSv. The nurses' maximum dose and dose rate were 16 μSv and 5.6 nSv·h"-"1·MBq"-"1. The visitors' maximum dose and dose rate were 6 μSv and 2.6 nSv·h"-"1·MBq"-"1. The nurses and visitors' exposure doses per patient were estimated to be negligible compared with the annual limit of the public. (author)

  7. A new turn-on fluorimetric method for the rapid speciation of Cr(III)/Cr(VI) species in tea samples with rhodamine-based fluorescent reagent

    Science.gov (United States)

    Özyol, Esra; Saçmacı, Şerife; Saçmacı, Mustafa; Ülgen, Ahmet

    2018-02-01

    A new fluorimetric method with rhodamine-based fluorescent agent was developed for the rapid speciation of Cr(III)/Cr(VI) in tea, soil and water samples. The system, which utilizes a fluorescent reagent, was used for the first time after synthesis/characterization of 3‧,6‧-bis(diethylamino)-2-{[(1E)-(2,4-dimethoxyphenyl)methylene] amino}spiro[isoindole-1,9‧-xanthen]-3(2H)-one (BDAS). The reagent responds instantaneously at room temperature in a 1:1 stoichiometric manner to the amount of Cr(III). The selectivity of this system for Cr(III) over other metal ions is remarkably high, and its sensitivity is below 0.01 mg L- 1 in aqueous solutions which enables a simplification without any pretreatment of the real sample. The method has a wide linear range of 0.1-10 mg L- 1 and a detection limit of 0.15 μg L- 1 for Cr(III) while the relative standard deviation was 0.1% for 0.1 mg L- 1 Cr(III) concentration. The results of detection and recovery experiments for Cr(III) in tea, soil and water were satisfactory, indicating that the method has better feasibility and application potential in the routine determination and speciation of Cr(III)/Cr(VI). The results of analysis of the certified reference material (INCT-TL-1 tea sample and CWW-TM-D waste water) are in good agreement with the certified value.

  8. Aluminothermic reduction of Cr2O3 contained in the ash of thermally treated leather waste

    Directory of Open Access Journals (Sweden)

    B. M. Wenzel

    2013-03-01

    Full Text Available In this study the viability of utilising ashes with high chromium oxide content, obtained by thermal treatment of footwear leather waste, in the production of low-carbon ferrochromium alloy (Fe-Cr-LC by aluminothermic reduction was investigated. The following key-factors were selected for process modelling: the quantity of aluminium (Al employed in the reaction, the iron amount added, the iron compound (Fe and/or Fe2O3 used, and the chromic acid addition. The process was investigated using a 2(4 full factorial design where the percentage of Cr2O3 reduced was used as the response. Variance analysis was employed to determine the significant effects and to validate the obtained model. The model was useful for finding the optimal operating conditions, including the maximisation of chromium conversion and the gross margin. Both resulted in similar process conditions, with 76.8±12.3% of chromium being reduced to the metallic phase, and 1.65±0.52 USD (kg ash-1 as the gross margin. The qualities of some alloys obtained were investigated by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy analysis (SEM/EDS. The results showed that the main problem for these alloys in a standard specification was the P and S content, suggesting that a pre-treatment is required.

  9. Characterization of Cr-doped Sb{sub 2}Te{sub 3} films and their application to phase-change memory

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qing; Xia, Yangyang; Zheng, Yonghui [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); University of the Chinese Academy of Sciences, Beijing, 100049 (China); Shanghai Key Laboratory of Nanofabrication Technology for Memory, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); Liu, Bo; Zhu, Min; Song, Sannian; Lv, Shilong; Cheng, Yan; Song, Zhitang; Feng, Songlin [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); Shanghai Key Laboratory of Nanofabrication Technology for Memory, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); Huo, Ruru [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); Shanghai Key Laboratory of Nanofabrication Technology for Memory, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050 (China); Shanghaitech University, Shanghai, 200031 (China)

    2015-08-15

    Phase-change memory (PCM) is regarded as one of the most promising candidates for the next-generation nonvolatile memory. Its storage medium, phase-change material, has attracted continuous exploration. Along the traditional GeTe-Sb{sub 2}Te{sub 3} tie line, the binary compound Sb{sub 2}Te{sub 3} is a high-speed phase-change material matrix. However, the low crystallization temperature prevents its practical application in PCM. Here, Cr is doped into Sb{sub 2}Te{sub 3}, called Cr-Sb{sub 2}Te{sub 3} (CST), to improve the thermal stability. We find that, with increase of the Cr concentration, grains are obviously refined. However, all the CST films exhibit a single hexagonal phase as Sb{sub 2}Te{sub 3} without phase separation. Also, the Cr helps to inhibit oxidation of Sb atoms. For the selected film CST{sub 1}0.5, the resistance ratio between amorphous and crystalline states is more than two orders of magnitude; the temperature for 10-year data retention is 120.8 C, which indicates better thermal stability than GST and pure Sb{sub 2}Te{sub 3}. PCM cells based on CST{sub 1}0.5 present small threshold current/voltage (4 μA/0.67 V). In addition, the cell can be operated by a low SET/RESET voltage pulse (1.1 V/2.4 V) with 50 ns width. Thus, Cr-Sb{sub 2}Te{sub 3} with suitable composition is a promising novel phase-change material used for PCM with high speed and good thermal stability performances. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium

    International Nuclear Information System (INIS)

    Zifoyda, Jackson M.; Challens, Cameron H.C.; Hsieh, Wen-Long

    2016-01-01

    When implementing Acuros XB (AXB) as a substitute for anisotropic analytic algorithm (AAA) in the Eclipse Treatment Planning System, one is faced with a dilemma of reporting either dose to medium, AXB-Dm or dose to water, AXB-Dw. To assist with decision making on selecting either AXB-Dm or AXB-Dw for dose reporting, a retrospective study of treated patients for head & neck (H&N), prostate, breast and lung is presented. Ten patients, previously treated using AAA plans, were selected for each site and re-planned with AXB-Dm and AXB-Dw. Re-planning was done with fixed monitor units (MU) as well as non-fixed MUs. Dose volume histograms (DVH) of targets and organs at risk (OAR), were analyzed in conjunction with ICRU-83 recommended dose reporting metrics. Additionally, comparisons of plan homogeneity indices (HI) and MUs were done to further highlight the differences between the algorithms. Results showed that, on average AAA overestimated dose to the target volume and OARs by less than 2.0 %. Comparisons between AXB-Dw and AXB-Dm, for all sites, also showed overall dose differences to be small (<1.5 %). However, in non-water biological media, dose differences between AXB-Dw and AXB-Dm, as large as 4.6 % were observed. AXB-Dw also tended to have unexpectedly high 3D maximum dose values (>135 % of prescription dose) for target volumes with high density materials. Homogeneity indices showed that AAA planning and optimization templates would need to be adjusted only for the H&N and Lung sites. MU comparison showed insignificant differences between AXB-Dw relative to AAA and between AXB-Dw relative to AXB-Dm. However AXB-Dm MUs relative to AAA, showed an average difference of about 1.3 % signifying an underdosage by AAA. In conclusion, when dose is reported as AXB-Dw, the effect that high density structures in the PTV has on the dose distribution should be carefully considered. As the results show overall small dose differences between the algorithms, when transitioning

  11. The origin of anisotropy and high density of states in the electronic structure of Cr2GeC by means of polarized soft x-ray spectroscopy and ab initio calculations

    Science.gov (United States)

    Magnuson, Martin; Mattesini, Maurizio; Bugnet, Matthieu; Eklund, Per

    2015-10-01

    The anisotropy in the electronic structure of the inherently nanolaminated ternary phase Cr2GeC is investigated by bulk-sensitive and element selective soft x-ray absorption/emission spectroscopy. The angle-resolved absorption/emission measurements reveal differences between the in-plane and out-of-plane bonding at the (0001) interfaces of Cr2GeC. The Cr L 2, 3, C K, and Ge M 1, M 2, 3 emission spectra are interpreted with first-principles density-functional theory (DFT) including core-to-valence dipole transition matrix elements. For the Ge 4s states, the x-ray emission measurements reveal two orders of magnitude higher intensity at the Fermi level than DFT within the General Gradient Approximation (GGA) predicts. We provide direct evidence of anisotropy in the electronic structure and the orbital occupation that should affect the thermal expansion coefficient and transport properties. As shown in this work, hybridization and redistribution of intensity from the shallow 3d core levels to the 4s valence band explain the large Ge density of states at the Fermi level.

  12. First-principles investigation of Cr-doped Fe2B: Structural, mechanical, electronic and magnetic properties

    Science.gov (United States)

    Wei, Xiang; Chen, Zhiguo; Zhong, Jue; Wang, Li; Wang, Yipeng; Shu, Zhongliang

    2018-06-01

    The structural, mechanical, electronic and magnetic properties of Fe8-xCrxB4 (x = 0, 0.25, 0.5, 1, 2, 3, 4, 5, 6, 7 and 8) have been investigated by first-principles calculation. It was found that the calculated structural parameters are well consistent with available experimental data. Moreover, all studied compounds are thermodynamically stable phases. On the whole, the moduli of the compounds firstly increase and then decrease with the increase of Cr concentration, whereas the variation of hardness exhibits more fluctuations. All Cr-doped Fe2B have better ductility than Fe2B except Fe2Cr6B4 and Fe5Cr3B4. Interestingly, Fe4Cr4B4 is of not only the slightly larger hardness, but also much better ductility than Fe2B. As the Cr concentration is lower than 20 wt%, the hardness of Cr-doped Fe2B slightly decreases with increasing Cr, whereas the sharply increased hardness of (Fe, Cr)2B in Fe-B alloys or boriding layer should be attributed to the multiple alloying effects resulting from Cr and the other alloying elements. The electronic structures revealed that the Fe-B and/or Cr-B bonds are mainly responsible for their mechanical properties, and the M-N (M = Fe or Cr, N = Fe or Cr) bonds in 〈2 2 0〉 and 〈1 1 3〉 orientations show covalent character. Additionally, the magnetic moments (Ms) of the compounds do not monotonically decrease with increasing Cr.

  13. Creep-fatigue behavior of 2 1/4Cr-1Mo steel at 5500C in air and vacuum

    International Nuclear Information System (INIS)

    Asayama, T.; Cheng, S.Z.; Asada, Y.; Mitsuhashi, S.; Tachibana, Y.

    1987-01-01

    Following studies on creep-fatigue behaviors of 304 steel at 650 0 C (Asada et al (1980) and Morishita et al (1984), (1985), (1987)), 2 1/4Cr-1Mo steel was studied on its creep-fatigue behaviors at 550 0 C in air and vacuum of 100 and 0.1 μPa. The present study intends to give a base for an evaluation of the environmental effect through obtaining a pure creep-fatigue behavior of this steel which is free from the environmental effect. In the previous studies on 304 steel, tests were conducted in three kinds of environment of air, 100 and 0.1 μPa vacuum. It seemed to be plausible that the 0.1 μPa vacuum shows the pure creep-fatigue behavior of 304 steel at 650 0 C which is almost completely free from the environment. A creep-fatigue life in 0.1 μPa vacuum is almost one order of magnitude higher than that in air. The 100 μPa vacuum suggested that the environmental effect of air still remains but is so small that a creep-fatigue life in 100 μPa is same to that in 0.1 μPa in some strain wave forms. The present study intends to examine if similar observations are obtained with 2 1/4Cr-1Mo steel at 550 0 C. This paper describes the analysis of the overstress and damages, in addition to a creep-fatigue result. (orig.GL)

  14. CR-39 nuclear track detector used for neutron dosimetry: system calibration

    International Nuclear Information System (INIS)

    Saint Martin, G.; Lopez, F.; Bernaola, Omar A.

    2009-01-01

    Stacks composed by 1 mm thickness CR-39 foils and polyethylene and PVC films were evaluated to be used as neutron dosemeters. Irradiations were made with a calibrated 241 Am-Be source in a dose range from 0 to 3.1 mSv and the etching conditions were optimized. The measurements of number of tracks per surface unit in the CR-39 detectors showed a good linear behaviour as a function of the dose. The minimum detectable dose equivalent (MDDE) was calculated. (author)

  15. Dose dependence of microstructural evolution and mechanical properties of neutron irradiated copper and copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Singh, B N; Edwards, D J; Horsewell, A; Toft, P

    1995-09-01

    The present investigation of the effects of neutron irradiation on microstructures and mechanical properties of copper alloys is a part of the ITER (International Thermonuclear Experimental Reactor) programme. Tensile specimens of the candidate alloys Cu-Al{sub 2}O{sub 3}, CuCrZr and CuNiBe were irradiated with fission neutrons in the DR-3 reactor at Risoe with a flux of 2.5 x 10{sup 17} n/m{sup 2}s (E > 1 MeV, i.e. a dose rate of {approx}5 x 10{sup -8} dpa/s) to fluences of 5 x 10{sup 22}, 5 x 10{sup 23} and 1 x 10{sup 24} n/m{sup 2} (E > 1 MeV, i.e. displacement doses of 0.01, 0.1 and 0.2 dpa) at 47 deg. C. The Cu-Al{sub 2}O{sub 3} (CuA125) specimens, were irradiated in the as-cold worked state. Tensile properties and Vickers hardness of both irradiated and unirradiated specimens were determined at 22 deg. C. Pre- and post-deformation microstructures of irradiated as well as unirradiated specimens were examined using a transmission electron microscope. The fractured surfaces of tensile tested specimens were investigated in a scanning electron microscope. The results show the following general trend: (a) that the CuNiBe alloy is stronger than CuCrZr as well as Cu Al{sub 2}O{sub 3}, (b) that even relatively low dose irradiations cause significant increase in the yield strength, but rather drastic decreases in the uniform elongation of CuCrZr and CuNiBe alloys and that the low dose irradiation of the cold-worked Cu-Al{sub 2}O{sub 3} alloy causes a decrease in the yield strength and an increase in the uniform elongation, at higher doses irradiation hardening occurs. The SEM examinations of the fractured surfaces demonstrate that both unirradiated and irradiated specimens fracture in a ductile manner. The lack of uniform elongation in the irradiated copper alloys may be understood in terms of difficulty in dislocation generation due to pinning of grown-in dislocation by defect clusters (loops) at or around them. (EG) 5 tabs., 18 ills., 13 refs.

  16. Dose dependence of microstructural evolution and mechanical properties of neutron irradiated copper and copper alloys

    International Nuclear Information System (INIS)

    Singh, B.N.; Edwards, D.J.; Horsewell, A.; Toft, P.

    1995-09-01

    The present investigation of the effects of neutron irradiation on microstructures and mechanical properties of copper alloys is a part of the ITER (International Thermonuclear Experimental Reactor) programme. Tensile specimens of the candidate alloys Cu-Al 2 O 3 , CuCrZr and CuNiBe were irradiated with fission neutrons in the DR-3 reactor at Risoe with a flux of 2.5 x 10 17 n/m 2 s (E > 1 MeV, i.e. a dose rate of ∼5 x 10 -8 dpa/s) to fluences of 5 x 10 22 , 5 x 10 23 and 1 x 10 24 n/m 2 (E > 1 MeV, i.e. displacement doses of 0.01, 0.1 and 0.2 dpa) at 47 deg. C. The Cu-Al 2 O 3 (CuA125) specimens, were irradiated in the as-cold worked state. Tensile properties and Vickers hardness of both irradiated and unirradiated specimens were determined at 22 deg. C. Pre- and post-deformation microstructures of irradiated as well as unirradiated specimens were examined using a transmission electron microscope. The fractured surfaces of tensile tested specimens were investigated in a scanning electron microscope. The results show the following general trend: (a) that the CuNiBe alloy is stronger than CuCrZr as well as Cu Al 2 O 3 , (b) that even relatively low dose irradiations cause significant increase in the yield strength, but rather drastic decreases in the uniform elongation of CuCrZr and CuNiBe alloys and that the low dose irradiation of the cold-worked Cu-Al 2 O 3 alloy causes a decrease in the yield strength and an increase in the uniform elongation, at higher doses irradiation hardening occurs. The SEM examinations of the fractured surfaces demonstrate that both unirradiated and irradiated specimens fracture in a ductile manner. The lack of uniform elongation in the irradiated copper alloys may be understood in terms of difficulty in dislocation generation due to pinning of grown-in dislocation by defect clusters (loops) at or around them. (EG) 5 tabs., 18 ills., 13 refs

  17. Biosorption of Cr (VI) ions from electroplating industrial effluent using immobilized Aspergillus niger biomass.

    Science.gov (United States)

    Chhikara, S; Dhankhar, R

    2008-09-01

    A fungus, Aspergillus niger was chemically treated with 0.1 M H2SO4 and 0.1 N NaOH to form biosorbent and it was immobilized in calcium alginate beads. The biosorption capacity of immobilized biosorbents for Cr (VI) was found to depend on pH, contact time, biosorbent dose and initial concentration of Cr (VI). The maximum uptake of Cr (VI) was 92.5, 95.9 and 98.4 mg respectively at a pH of 1.5 and with an increase in pH up to 10.5 the metal uptake decreased gradually up to 38.75, 50.19 and 65.28 mg respectively for acid treated, untreated and base treated fungal biosorbents. Increase in biosorbent dose up to 1 g of biomass and contact time up to 60 min resulted in an increase in biosorption from 19.6, 15.6 and 26.1 mg at a biosorbent dose of 0.1 g 100 ml(-1) to 92.45, 95.7 and 98.52 mg at a biosorbent dose of 1.0 g 100 ml(-1) and then further increase in adsorbent dose and contact time did not resulted in more Cr (VI) adsorption by per unit weight of biosorbent. The value of Kad (adsorption rate constant) revealed the pseudo-first order nature of biosorption. The percentage metal uptake by the biosorbent was found to decrease upto 62.33, 52.67 and 83.5 percent respectively for acid treated, untreated and base treated fungal biosorbents at the 300 mgl(-1) Cr (VI) ion concentration. The resulted data was found to fit well in Langmuir model of adsorption isotherm with a high value of correlation coefficient. The value of Qmax, b (Langmuir constants), R(L) (separation factor) and delta G (Gibb's free energy) revealed the favourable nature of adsorption. The biosorbed metal was eluted from the biosorbent by using 0.1 M H2SO4 as elutant. Immobilized biosorbent can be reused for five consecutive biosorption/desorption cycles without apparent loss of efficiency after its reconditioning. The biosorbent was found to perform well in the electroplating industrial effluent.

  18. Ca{sub 2}Cr{sub 0.5}Ga{sub 1.5}O{sub 5}—An extremely redox-stable brownmillerite phase

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Kun; Amano Patino, Midori; Hayward, Michael A., E-mail: michael.hayward@chem.ox.ac.uk

    2015-02-15

    Investigation of the Ca{sub 2}Cr{sub x}Ga{sub 2−x}O{sub 5} compositional series reveals a maximum chromium solubility of 25%. The most chromium rich composition, Ca{sub 2}Cr{sub 0.5}Ga{sub 1.5}O{sub 5}, adopts a brownmillerite-type anion deficient perovskite structure described in space group Pnma (a=5.368 Å, b=14.547 Å, c=5.593 Å). Neutron powder diffraction data reveals rigorous B-site cation order, with all of the tetrahedral coordination sites occupied exclusively by gallium and the octahedral coordination sites occupied by gallium or chromium. Annealing studies reveals Ca{sub 2}Cr{sub 0.5}Ga{sub 1.5}O{sub 5} is stable in both oxidizing (100% O{sub 2}) and reducing (5% H{sub 2} in N{sub 2}) conditions up to 800 °C, suggesting it could find application as a stable host lattice for fuel cell electrodes or electrolytes with suitable doping to enhance catalytic behaviour and/or anionic conductivity. - Graphical abstract: Ca{sub 2}Cr{sub 0.5}Ga{sub 1.5}O{sub 5}, adopts a brownmillerite-type anion deficient perovskite structure yet it is stable in both oxidizing (100% O{sub 2}) and reducing (5% H{sub 2} in N{sub 2}) conditions up to 800 °C. - Highlights: • Anion deficient oxide stable to both oxidation and reduction up to 800 °C. • Cation-ordered brownmillerite structure determined by powder neutron diffraction. • Low solubility of Cr{sup 3+} in framework due to spherical d{sup 3} electron configuration.

  19. Effect of low-dose (1 kGy) gamma radiation and selected phosphates on the microflora of vacuum-packaged ground pork

    International Nuclear Information System (INIS)

    Ehioba, R.M.

    1987-01-01

    The effects of low-dose (1 kGy) gamma radiation and selected phosphates on the microbiology of refrigerated, vacuum-packaged ground pork were studied. Low-dose gamma radiation reduced the numbers of naturally occurring mesophiles, psychrotrophs, and anaerobes. The effect of low-dose radiation on the populations of lactic acid bacteria was minimal. On storage of the irradiated vacuum-packaged ground pork at 5 0 C, there was a partial bacterial recovery, suggesting sublethal bacterial injury due to irradiation. When 10 7 CFU/g of meat is taken to be the level beyond which the meat would be considered spoiled, uninoculated, vacuum-packaged ground pork treated with 1 kGy (100 krad) of gamma radiation had 3.5 more days of shelf-life in terms of psychrotrophic total counts. In relation to anaerobic bacterial numbers, meat shelf-life was extended 2.5 days, while the shelf-life of meat was extended 1 day in terms of aerobic mesophilic bacteria. Irradiation prolonged shelf-life in inoculated (10 5 CFU/g) meat for 1.0-1.5 days. Addition of 0.4% sodium acid pyrophosphate (SAPP) contributed 2 additional days to inoculated, irradiated vacuum-packaged ground pork shelf-life. However, SAPP had no added effect on naturally occurring microflora. Irradiation greatly decreased the numbers of gram-negative microorganisms, resulting in predominance of the gram-positive, nonsporeforming Lactobacillus and coryneform bacteria

  20. Interaction of low-intensity nuclear radiation dose with the human blood: Using the new technique of CR-39NTDs for an in vitro study

    International Nuclear Information System (INIS)

    Ismail, Asaad H.; Jaafar, Mohamad S.

    2011-01-01

    Complete blood counts were analyzed for 30 samples of human blood with radiation dose rate ranging between 10 and 41 μSv/h using a Radium-226 source with different time of exposure. A new technique involving a nuclear track detector type CR-39(CR-39 NTDs) was used to estimate the alpha particle density incident on the blood samples. The results show that the ranges of alpha particle in blood samples and on the surface of CR-39NTDs vary exponentially with energy of alpha particles. This depends on the restricted energy loss and target density. Changes in the blood components due to irradiation occurred for different durations of irradiation, and the duration of irradiation that influenced the blood samples in this study was 6 min. The change in red blood cell (RBC) was negligible, so it is less affected than other blood components. In addition, most changes in the blood contents began at a low radiation dose (10.38-13.41 μSv/h). For the doses 13.41-21.77 μSv/h, platelet (PLT) counts increased rapidly and adversely with the RBC and white blood cell (WBC) due to chromosomal aberration. Besides, rapid PLT count reduction rapidly at high dose (42.1 μSv h) causes thrombocytopenia; in contrast, WBC increased, which is an indication of cancer caused due to increase in alpha particle dose. Generally, our results are in agreement with the essentials of blood content and the principles of biological radiation interaction.

  1. First-Principles Calculations for Chemical Reaction between Sodium Diethyldithiocarbamate and Transition-Metal (Cr) atom to Produce Cr(DDC)3 and Cr(DDC)2ODDC

    Science.gov (United States)

    Setiyanto, Henry; Muhida, Rifki; Kishi, Tomoya; Rempillo, Ofelia; Rahman, Mahmudur; Dipojono, Hermawan Kresno; Di\\ {n}o, Wilson Agerico; Matsumoto, Shigeno; Kasai, Hideaki

    2006-10-01

    We investigate the chemical reaction between a Cr transition-metal atom and sodium diethyldithiocarbamate (NaDDC), a complexing agent used to detect and extract Cr in human blood samples. Using density-functional-theory-based calculations, we determine their stable structures of Cr(DDC)2ODDC and Cr(DDC)3 complexes and obtain their dissociation energies. We found dissociation energies of -10.66 and -3.24 eV for Cr(DDC)2ODDC and Cr(DDC)3 complexes, respectively. Hence, on the basis of dissociation energies, we have verified that the reaction of NaDDC with Cr produces Cr(DDC)2ODDC as a major product.

  2. Dose commitments due to radioactive releases from nuclear power plant sites: Methodology and data base. Supplement 1

    Energy Technology Data Exchange (ETDEWEB)

    Baker, D.A. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-06-01

    This manual describes a dose assessment system used to estimate the population or collective dose commitments received via both airborne and waterborne pathways by persons living within a 2- to 80-kilometer region of a commercial operating power reactor for a specific year of effluent releases. Computer programs, data files, and utility routines are included which can be used in conjunction with an IBM or compatible personal computer to produce the required dose commitments and their statistical distributions. In addition, maximum individual airborne and waterborne dose commitments are estimated and compared to 10 CFR Part 50, Appendix 1, design objectives. This supplement is the last report in the NUREG/CR-2850 series.

  3. Dose commitments due to radioactive releases from nuclear power plant sites: Methodology and data base. Supplement 1

    International Nuclear Information System (INIS)

    Baker, D.A.

    1996-06-01

    This manual describes a dose assessment system used to estimate the population or collective dose commitments received via both airborne and waterborne pathways by persons living within a 2- to 80-kilometer region of a commercial operating power reactor for a specific year of effluent releases. Computer programs, data files, and utility routines are included which can be used in conjunction with an IBM or compatible personal computer to produce the required dose commitments and their statistical distributions. In addition, maximum individual airborne and waterborne dose commitments are estimated and compared to 10 CFR Part 50, Appendix 1, design objectives. This supplement is the last report in the NUREG/CR-2850 series

  4. Substitution and diffusion of Cr 2+ and Cr 3+ in synthetic forsterite and natural olivine at 1200–1500 °C and 1 bar

    Energy Technology Data Exchange (ETDEWEB)

    Jollands, M. C.; O' Neill, H. St. C.; Van Orman, J.; Berry, A. J.; Hermann, J.; Newville, M.; Lanzirotti, A.

    2018-01-01

    The diffusion and substitution mechanisms of Cr in forsterite were studied as a function of crystallographic orientation and the chemical potentials of all four components in the system MgO-SiO2-Cr-O. Oxygen fugacity (fO2) was varied over 15.4 log units at 1400 °C and was fixed at the iron-wüstite equilibrium for a temperature series (1200–1500 °C). The valence state changes of Cr along some diffusion profiles was also investigated using X-ray absorption near edge structure spectroscopy.

  5. Evaluation of ferritic alloy Fe-2-1/4Cr-1Mo after neutron irradiation - microstructure development

    International Nuclear Information System (INIS)

    Gelles, D.S.

    1984-05-01

    Microstructural examinations are reported for nine specimen conditions of 2-1/4Cr-1Mo steel which had been irradiated by fast neutrons over the temperature range 390 to 510 0 C. Two heats of material were involved, each with a different preirradiation heat treatment, one irradiated to a peak fluence of 5.1 x 10 22 n/cm 2 (E > 0.1 MeV) or 24 dpa and the other to 2.4 x 10 23 n/cm 2 (E > 0.1 MeV) or 116 dpa. Void swelling is found following irradiation at 400 0 C in both conditions and to 480 0 C in the higher fluence conditions. Concurrently dislocation structure and precipitation formed. Peak void swelling, void density, dislocation density and precipitate number density developed at the lowest temperature, approx. 400 0 C, whereas mean void size, and mean precipitate size increased with increasing irradiation temperature. The examination results are used to provide interpretation of in-reactor creep, density change and post irradiation tensile behavior

  6. Effects of Cr-N-ZrO 2 seed layer formed on glass substrates for longitudinal recording media

    Science.gov (United States)

    Suzuki, Hiroyuki; Djayaprawira, David D.; Takahashi, Yoshio; Ishikawa, Akira; Ono, Toshinori; Yahisa, Yotsuo

    1999-03-01

    Effects of Cr-N-ZrO 2 seed layer deposited on glass substrates before the deposition of C/Co-Cr-Pt/Cr-Ti layers for longitudinal recording media have been investigated. The product of v and Is, the activation volume and the saturation magnetization per unit volume, media noise Nd and S0/ Nd, which is the half value of peak-to-peak output voltage of an isolated pulse over Nd at 11.8 kFC/mm, are evaluated. We find that vIs is decreased by adding N and ZrO 2 to Cr seed layer. Nd is reduced as vIs decreases by adding nitrogen to the Cr seed layer. This is mainly due to the decreased grain sizes of both Cr-Ti underlayer and Co-Cr-Pt magnetic layer. The Nd is further reduced by the addition of ZrO 2 to the Cr-N seed layer. Highest S0/ Nd is achieved for the media with Cr-N-ZrO 2 seed layer. On the other hand, the media with Cr-ZrO 2 seed layer deposited without nitrogen show the higher Nd. Therefore the decrease of the grain size by addition of nitrogen into Ar is essential to reduce Nd, and the ZrO 2 addition to the Cr-N seed layer seems to enhance the effect of grain size reduction by nitrogen addition.

  7. Study of 2D MXene Cr{sub 2}C material for hydrogen storage using density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, A. [Department of Physics and National Centre for Nanosciences & Nanotechnology, University of Mumbai, Vidyanagari, Santacruz (E), Mumbai 400 098 (India); Dashora, Alpa, E-mail: dashoralpa@gmail.com [UM-DAE Centre for Excellence in Basic Sciences, Vidyanagari, Santacruz (E), Mumbai 400 098 (India); Patel, N. [Department of Physics and National Centre for Nanosciences & Nanotechnology, University of Mumbai, Vidyanagari, Santacruz (E), Mumbai 400 098 (India); Dipartimento di Fisica, Università degli Studi di Trento, I-38123 Povo, Trento (Italy); Miotello, A. [Dipartimento di Fisica, Università degli Studi di Trento, I-38123 Povo, Trento (Italy); Press, M.; Kothari, D.C. [Department of Physics and National Centre for Nanosciences & Nanotechnology, University of Mumbai, Vidyanagari, Santacruz (E), Mumbai 400 098 (India)

    2016-12-15

    Highlights: • First-principles studies showed that Cr{sub 2}C MXene can store 7.6 wt.% of H{sub 2}. • 6.4 wt.% H{sub 2} can be reversibly stored at ambient temperature. • Charge transfer between H and Cr is responsible for the reversible H{sub 2} adsorption. • H-atom on hollow site between three Cr atoms is the most stable site. - Abstract: Hydrogen storage capacity of 2D MXene Cr{sub 2}C has been studied using density functional theory. Possibility to adsorb H{sub 2} molecule on Cr{sub 2}C surface at various sites has been studied. Among the studied adsorption sites on Cr{sub 2}C surface, few sites were found suitable for chemisorption and physisorption of H{sub 2} molecules. Few of the studied sites are also found to be suitable for Kubas-type interaction, which is useful for reversible hydrogen storage at ambient conditions. Electronic structure calculations and charge transfer analysis have been done to understand the interactions of adsorbed hydrogen with the Cr{sub 2}C layer. It has been found that the total hydrogen storage capacity of Cr{sub 2}C is 7.6 wt.% in which 1.2 wt.% of H is due to the chemisorption, 3.2 wt.% is bonded with Kubas-interaction and remaining 3.2 wt.% is bonded through weak electrostatic interactions (with binding energy of 0.26 eV/H{sub 2} and charge transfer of 0.09 e{sup −} to H atom from Cr atom). Thus the reversible hydrogen storage capacity at ambient conditions (controlled by hydrogen bonded with energies ranging from 0.1 to 0.4 eV/H{sub 2}, in the present case through Kubas and weak electrostatic interactions) is 6.4 wt.% which is greater than the 2017 DoE recommended target value of 5.5 wt.%.

  8. Cr diffusion in MgAl2O4 synthetic spinels: preliminary results

    Science.gov (United States)

    Freda, C.; Celata, B.; Andreozzi, G.; Perinelli, C.; Misiti, V.

    2012-04-01

    preliminary data, we have estimated a diffusion coefficient of chromium (D) of 7.6·10-15 m2s-1.

  9. Interface Resistance between FeCr Interconnects and La0.85Sr0.15Mn1.1O3

    DEFF Research Database (Denmark)

    Mikkelsen, Lars; Neufeld, Kai; Hendriksen, Peter Vang

    2009-01-01

    The long term oxidation behaviour and the electrical interface resistance between FeCr interconnects and La0,85Sr0,15Mn1,1O3 plates was studied by a DC four-point method in air at 750{degree sign}C for 10000 h. The tested FeCr alloys were: Crofer 22 APU, Sanergy HT, Plansee IT10, Plansee IT11, an....... Low degradation rates of less than 1 mcm2/1000 h were measured on all interfaces. The microstructure analysis showed that a duplex Cr2O3-(Mn,Co,Cr)3O4 oxide scale with a thickness of 3-5 µm had evolved on the alloys....

  10. Optimization of CR-39 for fast neutron dosimetry applications

    International Nuclear Information System (INIS)

    Vilela, E.; Fantuzzi, E.; Giacomelli, G.; Giorgini, M.; Morelli, B.; Patrizii, L.; Serra, P.; Togo, V.

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: 241 Am-Be, 252 Cf and 238 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose

  11. 2-Amino-3-(3-hydroxy-1,2,5-thiadiazol-4-yl)propionic acid

    DEFF Research Database (Denmark)

    Johansen, Tommy N; Janin, Yves L; Nielsen, Birgitte

    2002-01-01

    In order to identify new subtype-selective (S)-glutamate (Glu) receptor ligands we have synthesized (RS)-2-amino-3-(3-hydroxy-1,2,5-thiadiazol-4-yl)propionic acid [(RS)-TDPA]. Resolution of (RS)-TDPA by chiral chromatography was performed using a Crownpac CR(+) column affording (R)- and (S......)-TDPA of high enantiomeric purity (enantiomeric excess=99.9%). An X-ray crystallographic analysis revealed that the early eluting enantiomer has R-configuration. Both enantiomers showed high affinity as well as high agonist activity at (RS)-2-amino-3-(3-hydroxy-5-methylisoxazol-4-yl)propionic acid (AMPA...... a remarkably low AMPA receptor stereoselectivity, (S)-TDPA showing the highest affinity and (R)-TDPA the most potent agonist activity. In addition, (S)-TDPA was shown to interact with synaptosomal Glu uptake sites displacing [(3)H](R)-aspartic acid (IC(50 ) approximately 390 microM). An enantiospecific...

  12. Ship-in-a-bottle CMPO in MIL-101(Cr) for selective uranium recovery from aqueous streams through adsorption

    Energy Technology Data Exchange (ETDEWEB)

    De Decker, Jeroen [Department of Inorganic and Physical Chemistry, Center for Ordered Materials, Organometallics, and Catalysis (COMOC), Ghent University, Krijgslaan 281-S3, 9000 Ghent (Belgium); Folens, Karel [Laboratory of Analytical Chemistry and Applied Ecochemistry, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); De Clercq, Jeriffa [Department of Materials, Textiles, and Chemical Engineering, Industrial Catalysis and Adsorption Technology (INCAT), Ghent University, Valentin, Vaerwyckweg 1, 9000 Ghent (Belgium); Meledina, Maria; Van Tendeloo, Gustaaf [EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Du Laing, Gijs [Laboratory of Analytical Chemistry and Applied Ecochemistry, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); Van Der Voort, Pascal, E-mail: pascal.vandervoort@ugent.be [Department of Inorganic and Physical Chemistry, Center for Ordered Materials, Organometallics, and Catalysis (COMOC), Ghent University, Krijgslaan 281-S3, 9000 Ghent (Belgium)

    2017-08-05

    Highlights: • Highly stable metal-organic framework, MIL-101(Cr), for uses in aqueous, acidic adsorption. • Uranium recovery from low concentration acidic solutions. • One-step ship-around-the-bottle synthetic approach to incorporate CMPO in MIL-101(Cr). • Highly selective U(VI) adsorbent in competition with a high variety of metals, incl. rare earths and transition metals. • Regenerable and reusable adsorbent via 0.1 M nitric acid stripping. - Abstract: Mesoporous MIL-101(Cr) is used as host for a ship-in-a-bottle type adsorbent for selective U(VI) recovery from aqueous environments. The acid-resistant cage-type MOF is built in-situ around N,N-Diisobutyl-2-(octylphenylphosphoryl)acetamide (CMPO), a sterically demanding ligand with high U(VI) affinity. This one-step procedure yields an adsorbent which is an ideal compromise between homogeneous and heterogeneous systems, where the ligand can act freely within the pores of MIL-101, without leaching, while the adsorbent is easy separable and reusable. The adsorbent was characterized by XRD, FTIR spectroscopy, nitrogen adsorption, XRF, ADF-STEM and EDX, to confirm and quantify the successful encapsulation of the CMPO in MIL-101, and the preservation of the host. Adsorption experiments with a central focus on U(VI) recovery were performed. Very high selectivity for U(VI) was observed, while competitive metal adsorption (rare earths, transition metals...) was almost negligible. The adsorption capacity was calculated at 5.32 mg U/g (pH 3) and 27.99 mg U/g (pH 4), by fitting equilibrium data to the Langmuir model. Adsorption kinetics correlated to the pseudo-second-order model, where more than 95% of maximum uptake is achieved within 375 min. The adsorbed U(VI) is easily recovered by desorption in 0.1 M HNO{sub 3}. Three adsorption/desorption cycles were performed.

  13. Ship-in-a-bottle CMPO in MIL-101(Cr) for selective uranium recovery from aqueous streams through adsorption

    International Nuclear Information System (INIS)

    De Decker, Jeroen; Folens, Karel; De Clercq, Jeriffa; Meledina, Maria; Van Tendeloo, Gustaaf; Du Laing, Gijs; Van Der Voort, Pascal

    2017-01-01

    Highlights: • Highly stable metal-organic framework, MIL-101(Cr), for uses in aqueous, acidic adsorption. • Uranium recovery from low concentration acidic solutions. • One-step ship-around-the-bottle synthetic approach to incorporate CMPO in MIL-101(Cr). • Highly selective U(VI) adsorbent in competition with a high variety of metals, incl. rare earths and transition metals. • Regenerable and reusable adsorbent via 0.1 M nitric acid stripping. - Abstract: Mesoporous MIL-101(Cr) is used as host for a ship-in-a-bottle type adsorbent for selective U(VI) recovery from aqueous environments. The acid-resistant cage-type MOF is built in-situ around N,N-Diisobutyl-2-(octylphenylphosphoryl)acetamide (CMPO), a sterically demanding ligand with high U(VI) affinity. This one-step procedure yields an adsorbent which is an ideal compromise between homogeneous and heterogeneous systems, where the ligand can act freely within the pores of MIL-101, without leaching, while the adsorbent is easy separable and reusable. The adsorbent was characterized by XRD, FTIR spectroscopy, nitrogen adsorption, XRF, ADF-STEM and EDX, to confirm and quantify the successful encapsulation of the CMPO in MIL-101, and the preservation of the host. Adsorption experiments with a central focus on U(VI) recovery were performed. Very high selectivity for U(VI) was observed, while competitive metal adsorption (rare earths, transition metals...) was almost negligible. The adsorption capacity was calculated at 5.32 mg U/g (pH 3) and 27.99 mg U/g (pH 4), by fitting equilibrium data to the Langmuir model. Adsorption kinetics correlated to the pseudo-second-order model, where more than 95% of maximum uptake is achieved within 375 min. The adsorbed U(VI) is easily recovered by desorption in 0.1 M HNO 3 . Three adsorption/desorption cycles were performed.

  14. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol.2

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  15. The spectrum of resistance in SR/CR mice: the critical role of chemoattraction in the cancer/leukocyte interaction.

    Science.gov (United States)

    Riedlinger, Gregory; Adams, Jonathan; Stehle, John R; Blanks, Michael J; Sanders, Anne M; Hicks, Amy M; Willingham, Mark C; Cui, Zheng

    2010-05-03

    Spontaneous regression/complete resistance (SR/CR) mice are a unique colony of mice that possess an inheritable, natural cancer resistance mediated primarily by innate cellular immunity. This resistance is effective against sarcoma 180 (S180) at exceptionally high doses and these mice remain healthy. In this study, we challenged SR/CR mice with additional lethal transplantable mouse cancer cell lines to determine their resistance spectrum. The ability of these transplantable cancer cell lines to induce leukocyte infiltration was quantified and the percentage of different populations of responding immune cells was determined using flow cytometry. In comparison to wild type (WT) mice, SR/CR mice showed significantly higher resistance to all cancer cell lines tested. However, SR/CR mice were more sensitive to MethA sarcoma (MethA), B16 melanoma (B16), LL/2 lung carcinoma (LL/2) and J774 lymphoma (J774) than to sarcoma 180 (S180) and EL-4 lymphoma (EL-4). Further mechanistic studies revealed that this lower resistance to MethA and LL/2 was due to the inability of these cancer cells to attract SR/CR leukocytes, leading to tumor cell escape from resistance mechanism. This escape mechanism was overcome by co-injection with S180, which could attract SR/CR leukocytes allowing the mice to resist higher doses of MethA and LL/2. S180-induced cell-free ascites fluid (CFAF) co-injection recapitulated the results obtained with live S180 cells, suggesting that this chemoattraction by cancer cells is mediated by diffusible molecules. We also tested for the first time whether SR/CR mice were able to resist additional cancer cell lines prior to S180 exposure. We found that SR/CR mice had an innate resistance against EL-4 and J774. Our results suggest that the cancer resistance in SR/CR mice is based on at least two separate processes: leukocyte migration/infiltration to the site of cancer cells and recognition of common surface properties on cancer cells. The infiltration of SR/CR

  16. The spectrum of resistance in SR/CR mice: the critical role of chemoattraction in the cancer/leukocyte interaction

    International Nuclear Information System (INIS)

    Riedlinger, Gregory; Adams, Jonathan; Stehle, John R Jr; Blanks, Michael J; Sanders, Anne M; Hicks, Amy M; Willingham, Mark C; Cui, Zheng

    2010-01-01

    Spontaneous regression/complete resistance (SR/CR) mice are a unique colony of mice that possess an inheritable, natural cancer resistance mediated primarily by innate cellular immunity. This resistance is effective against sarcoma 180 (S180) at exceptionally high doses and these mice remain healthy. In this study, we challenged SR/CR mice with additional lethal transplantable mouse cancer cell lines to determine their resistance spectrum. The ability of these transplantable cancer cell lines to induce leukocyte infiltration was quantified and the percentage of different populations of responding immune cells was determined using flow cytometry. In comparison to wild type (WT) mice, SR/CR mice showed significantly higher resistance to all cancer cell lines tested. However, SR/CR mice were more sensitive to MethA sarcoma (MethA), B16 melanoma (B16), LL/2 lung carcinoma (LL/2) and J774 lymphoma (J774) than to sarcoma 180 (S180) and EL-4 lymphoma (EL-4). Further mechanistic studies revealed that this lower resistance to MethA and LL/2 was due to the inability of these cancer cells to attract SR/CR leukocytes, leading to tumor cell escape from resistance mechanism. This escape mechanism was overcome by co-injection with S180, which could attract SR/CR leukocytes allowing the mice to resist higher doses of MethA and LL/2. S180-induced cell-free ascites fluid (CFAF) co-injection recapitulated the results obtained with live S180 cells, suggesting that this chemoattraction by cancer cells is mediated by diffusible molecules. We also tested for the first time whether SR/CR mice were able to resist additional cancer cell lines prior to S180 exposure. We found that SR/CR mice had an innate resistance against EL-4 and J774. Our results suggest that the cancer resistance in SR/CR mice is based on at least two separate processes: leukocyte migration/infiltration to the site of cancer cells and recognition of common surface properties on cancer cells. The infiltration of SR/CR

  17. Molecular beam and pulsed laser deposition of ZnS:Cr for intermediate band solar cells

    OpenAIRE

    Nematollahi, Mohammadreza; Yang, Xiaodong; Aas, Lars Martin Sandvik; Ghadyani, Zahra; Kildemo, Morten; Gibson, Ursula; Reenaas, Turid Worren

    2015-01-01

    We have investigated the structural and optical properties of Cr-doped ZnS (ZnS:Cr) thin films (0–7.5 at.% Cr) for use in intermediate band solar cells. The films were grown on Si(100) in molecular beam epitaxy (MBE) and pulsed laser deposition (PLD) equipments. Introducing Cr into ZnS resulted in Cr related subbandgap absorption, but also reduced the grain size. The sub-bandgap absorption increased with increasing Cr content, and with increasing growth temperature, but did not depend on the ...

  18. Effect of heat treatments on precipitate microstructure and mechanical properties of CuCrZr alloy

    DEFF Research Database (Denmark)

    Singh, B.N; Edwards, D.J.; Tähtinen, S.

    2004-01-01

    A number of specimens of CuCrZr alloy was prime aged and then overaged at 600oC for 1, 2 and 4 hours and for 4 hours at 700 and 850oC. After different heat treatments, both the precipitate microstructure and mechanical properties were characterized.Mechanical properties were determined at 50...... and 300oC. Some selected specimens in the prime aged as well as overaged conditions were irradiated in the BR-2 reactor at Mol at 60 and 300oC to a displacement dose level of ~0.3 dpa. Irradiated specimens weremechanically tested at 60 and 300oC. The post-deformation microstructure of the irradiated...

  19. Study of the oxidation of Fe-Cr alloys at high temperatures

    International Nuclear Information System (INIS)

    Carneiro, J.F.; Sabioni, A.C.S.

    2010-01-01

    The high temperature oxidation behavior of Fe-1.5%Cr, Fe-5.0%Cr, Fe-10%Cr and Fe- 15%Cr model alloys were investigated from 700 to 850 deg C, in air atmosphere. The oxidation treatments were performed in a thermobalance with a sensitivity of 1μg. The oxide films grown by oxidation of the alloys were characterized by scanning electronic microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The oxide films are Fe-Cr spinels with variable composition depending on the alloy composition. For all conditions studied, the oxidation kinetics of these alloys follow a parabolic law. The comparison of the oxidation rates of the four alloys, at 700 deg C, shows that the parabolic oxidation constants decrease from 1.96x10 -9 g 2 .cm -4 .s -1 , for the alloy Fe-1.5% Cr, to 1.18 x 10-14g 2 .cm -4 .s -1 for the alloy Fe-15% Cr. Comparative analysis of the oxidation behavior of the Fe-10%Cr and Fe-15%Cr alloys, between 700 and 850 deg C, shows that the oxidation rates of these alloys are comparable to 800 deg C, above this temperature the Fe-10%Cr alloy shows lower resistance to oxidation. (author)

  20. K4Nb6O17·4.5H2O: A novel dual functional material with quick photoreduction of Cr(VI) and high adsorptive capacity of Cr(III)

    International Nuclear Information System (INIS)

    Ma, Yuli; Liu, Xiaoqing; Li, Yang; Su, Yiguo; Chai, Zhanli; Wang, Xiaojing

    2014-01-01

    Graphical abstract: A well crystalline K 4 Nb 6 O 17 ·4.5H 2 O with a wide layer spacing possesses an excellent disposal performance for chromium species of Cr(VI) and Cr(III) as well as the superior recyclability due to its high stability and convenient regeneration process. - Highlights: • A nano-sheet K 4 Nb 6 O 17 ·4.5H 2 O with a large layer spacing was synthesized. • K 4 Nb 6 O 17 ·4.5H 2 O showed a superior photoreduction of Cr(VI) in an acidic solution. • The sample showed a high adsorption capacity of Cr(III) in a near neutral solution. • K 4 Nb 6 O 17 ·4.5H 2 O regenerated conveniently by immersing in a KOH solution. • A complete removal of chromium species was retained after recycling five times. - Abstract: A series of orthorhombic phase K 4 Nb 6 O 17 ·4.5H 2 O was synthesized via a hydrothermal approach. When presented in an acidic pH range, K 4 Nb 6 O 17 ·4.5H 2 O showed a strong ability in quick reduction from Cr(VI) to Cr(III). The resulted Cr(III) ions were removed by an effective adsorption through simply adjusting the solution pH from strong acidity to near neutrality, owing to the sample's unique nano-sheet structure with a wide layer spacing. The Cr(III) ions adsorbed onto samples were released again for reusing by eluting with 1 mol L −1 HCl solution, and K 4 Nb 6 O 17 ·4.5H 2 O regenerated by immersing in a KOH solution. The reduction efficiency of Cr(VI) was still up to 98% after irradiation for 60 min, and the removal efficiency of Cr(III) ions was as high as 83% even after five cycles. Therefore, K 4 Nb 6 O 17 ·4.5H 2 O is clearly demonstrated to be an excellent dual functional material with quick photoreduction of Cr(VI) and high adsorptive capacity of Cr(III). The relevant materials reported herein might be found various environment-related applications

  1. Radiation dose reduction for patients with extranodal NK/T-cell lymphoma with complete response after initial induction chemotherapy

    Directory of Open Access Journals (Sweden)

    Wang L

    2016-09-01

    Full Text Available Liang Wang,1,2,* Xi-wen Bi,1,3,* Zhong-jun Xia,1,2 Hui-qiang Huang,1,3 Wen-qi Jiang,1,3 Yu-jing Zhang1,4 1State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 2Department of Hematologic Oncology, 3Department of Medical Oncology, 4Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Previous studies have found that radiotherapy (RT dose less than 50 Gy resulted in inferior outcomes for early stage extranodal NK/T-cell lymphoma (ENKTL. Nowadays, induction chemotherapy (CT followed by RT consolidation is often used. For patients who get complete response (CR after CT, whether RT dose can be safely reduced or not remains unknown. This retrospective study compared the survival outcomes between patients who received higher dose (>50 Gy and lower dose (≤50 Gy RT after CR was attained by CT. One hundred and forty four patients of early stage ENKTL got CR after induction CT and received RT consolidation. Thirty-one patients received lower dose RT (median 46 Gy, range, 36–50 Gy, and 113 patients received higher dose RT (median 56 Gy, range, 52–66 Gy. In univariate survival analysis, age >60, local tumor invasion, and non-asparaginase-based CT were associated with inferior progression-free survival (PFS and overall survival (OS. However, there were no differences in PFS and OS between patients treated with higher and lower dose RT, which was confirmed in the multivariate survival analysis. Furthermore, reduced dose RT did not affect local control rate. Most common RT-related side effects were grade 1/2 mucositis and dermatitis, and the incidence rate of grade 3 mucositis or dermatitis was lower in patients treated with reduced dose RT (9.7% vs 15.0% for mucositis, and 6.5% vs 17.7% for dermatitis. In conclusion, this study found that RT dose could be safely reduced without

  2. Limits of dose escalation in lung cancer: a dose-volume histogram analysis comparing coplanar and non-coplanar techniques

    Energy Technology Data Exchange (ETDEWEB)

    Derycke, S; Van Duyse, B; Schelfhout, J; De Neve, W

    1995-12-01

    To evaluate the feasibility of dose escalation in radiotherapy of inoperable lung cancer, a dose-volume histogram analysis was performed comparing standard coplanar (2D) with non-coplanar (3D) beam arrangements on a non-selected group of 20 patients planned by Sherouse`s GRATISTM 3D-planning system. Serial CT-scanning was performed and 2 Target Volumes (Tvs) were defined. Gross Tumor Volume (GTV) defined a high-dose Target Volume (TV-1). GTV plus location of node stations with > 10% probability of invasion (Minet et al.) defined an intermediate-dose Target Volume (TV-2). However, nodal regions which are incompatible with cure were excluded from TV-2. These are ATS-regions 1, 8, 9 and 14 all left and right as well as heterolateral regions. For 3D-planning, Beam`s Eye View selected (by an experienced planner) beam arrangements were optimised using Superdot, a method of target dose-gradient annihilation developed by Sherouse. A second 3D-planning was performed using 4 beam incidences with maximal angular separation. The linac`s isocenter for the optimal arrangement was located at the geometrical center of gravity of a tetraheder, the tetraheder`s comers being the consecutive positions of the virtual source. This ideal beam arrangement was approximated as close as possible, taking into account technical limitations (patient-couch-gantry collisions). Criteria for tolerance were met if no points inside the spinal cord exceeded 50 Gy and if at least 50% of the lung volume received less than 20Gy. If dose regions below 50 Gy were judged acceptable at TV-2, 2D- as well as 3D-plans allow safe escalation to 80 Gy at TV-1. When TV-2 needed to be encompassed by isodose surfaces exceeding 50Gy, 3D-plans were necessary to limit dose at the spinal cord below tolerance. For large TVs dose is limited by lung tolerance for 3D-plans. An analysis (including NTCP-TCP as cost functions) of rival 3D-plans is being performed.

  3. Growth of Sr2CrReO6 epitaxial thin films by pulsed laser deposition

    International Nuclear Information System (INIS)

    Orna, J.; Morellon, L.; Algarabel, P.A.; Pardo, J.A.; Magen, C.; Varela, M.; Pennycook, S.J.; De Teresa, J.M.; Ibarra, M.R.

    2010-01-01

    We report the growth, structural, magnetic, and electrical transport properties of epitaxial Sr 2 CrReO 6 thin films. We have succeeded in depositing films with a high crystallinity and a relatively large cationic order in a narrow window of growth parameters. The epitaxy relationship is Sr 2 CrReO 6 (SCRO) (0 0 1) [1 0 0]-parallel SrTiO 3 (STO) (0 0 1) [1 1 0] as determined by high-resolution X-ray diffraction and scanning transmission electron microscopy (STEM). Typical values of saturation magnetization of M S (300 K)=1 μ B /f.u. and ρ (300 K)=2.8 mΩ cm have been obtained in good agreement with previous published results in sputtered epitaxial thin films. We estimate that the antisite defects concentration in our thin films is of the order of 14%, and the measured Curie temperature is T C =481(2) K. We believe these materials be of interest as electrodes in spintronic devices.

  4. Microwave dielectric properties and microstructure of Ba{sub 6−3x}Nd{sub 8+2x}Ti{sub 18−y}(Cr{sub 1/2}Nb{sub 1/2}){sub y}O{sub 54} ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xia [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Jianshe Road, Chengdu 610054 (China); Tang, Bin, E-mail: tangbin@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Jianshe Road, Chengdu 610054 (China); Liu, Jiaqin [Sichuan Special Equipment Inspection Institute, Dongfeng Road, Chengdu 610061 (China); Chen, Hetuo; Zhang, Shuren [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Jianshe Road, Chengdu 610054 (China)

    2015-10-15

    The microwave dielectric properties and the morphology of Ba{sub 6−3x}Nd{sub 8+2x}Ti{sub 18−y}(Cr{sub 1/2}Nb{sub 1/2}){sub y}O{sub 54} (x = 0.75, 0 ≤ y ≤ 3.0) ceramics prepared under different sintering conditions were investigated in this work. The effects of substitutions on the microstructure and microwave dielectric properties were discussed. The X-ray diffraction (XRD) patterns of the sintered samples revealed a single-phase formation BaNd{sub 2}Ti{sub 4}O{sub 12} with a tungsten bronze type structure in the system. The results of energy dispersive spectrometer (EDS) and lattice parameters calculated on XRD data could confirm the substitution at B-site. A small amount of substitutions improved quality factor value (Q × f) and the temperature coefficient of resonant frequency (τ{sub f}) but led to a decrease of the permittivity. The temperature coefficient of resonant frequency (τ{sub f}) was found to decrease with increasing substitutions because of the declination of tolerance factor (t). And the τ{sub f} could be adjusted from +62.4 ppm/°C to −7.3 ppm/°C with increment of substitutions. Finally, excellent dielectric properties were obtained as y was 0.5 sintered at 1400 °C for 2 h in air: ε{sub r} = 88.6, Q × f = 11486 GHz, τ{sub f} = +37.1 ppm/°C. - Graphical abstract: It was evident that the tendency of the τ{sub f} was consistent with the variation of tolerance factor (t). The τ{sub f} was much affected by the titling of Ti–O octahedral that bigger ionic radius of (Cr{sub 1/2}Nb{sub 1/2}){sup 4+} substituted for Ti{sup 4+} would significantly reduce the temperature coefficient of resonant frequency. - Highlights: • (Cr{sub 1/2}Nb{sub 1/2}){sup 4+} substitution for Ti{sup 4+} would low down the τ{sub f} of the samples. • The Cr{sup 3+} substitution for Ti{sup 4+} would promote the quality factor. • (Cr{sub 1/2}Nb{sub 1/2}){sup 4+} substitution for Ti{sup 4+} makes the permittivity maintain a high value. • The high Q × f

  5. Specific Reagent for Cr(III): Imaging Cellular Uptake of Cr(III) in Hct116 Cells and Theoretical Rationalization.

    Science.gov (United States)

    Ali, Firoj; Saha, Sukdeb; Maity, Arunava; Taye, Nandaraj; Si, Mrinal Kanti; Suresh, E; Ganguly, Bishwajit; Chattopadhyay, Samit; Das, Amitava

    2015-10-15

    A new rhodamine-based reagent (L1), trapped inside the micellar structure of biologically benign Triton-X 100, could be used for specific recognition of Cr(III) in aqueous buffer medium having physiological pH. This visible light excitable reagent on selective binding to Cr(III) resulted in a strong fluorescence turn-on response with a maximum at ∼583 nm and tail of that luminescence band extended until 650 nm, an optical response that is desired for avoiding the cellular autofluorescence. Interference studies confirm that other metal ions do not interfere with the detection process of Cr(III) in aqueous buffer medium having pH 7.2. To examine the nature of binding of Cr(III) to L1, various spectroscopic studies are performed with the model reagent L2, which tend to support Cr(III)-η(2)-olefin π-interactions involving two olefin bonds in molecular probe L1. Computational studies are also performed with another model reagent LM to examine the possibility of such Cr(III)-η(2)-olefin π-interactions. Presumably, polar functional groups of the model reagent LM upon coordination to the Cr(III) center effectively reduce the formal charge on the metal ion and this is further substantiated by results of the theoretical studies. This assembly is found to be cell membrane permeable and shows insignificant toxicity toward live colon cancer cells (Hct116). Confocal laser scanning microscopic studies further revealed that the reagent L1 could be used as an imaging reagent for detection of cellular uptake of Cr(III) in pure aqueous buffer medium by Hct116 cells. Examples of a specific reagent for paramagnetic Cr(III) with luminescence ON response are scanty in the contemporary literature. This ligand design helped us in achieving the turn on response by utilizing the conversion from spirolactam to an acyclic xanthene form on coordination to Cr(III).

  6. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-Xochimilco, 04960 Mexico D.F. (Mexico); Azorin N, J. [UAM-Iztapalapa, 09340 Mexico D.F. (Mexico); Diaz G, J.A.I. [CICATA, Unidad Legaria, Av. Legaria 694, 11599 mexico D.F. (Mexico); Arreola, M. [Department of Radiology, Shands Hospital at UF, PO Box 100374, Gainesville, FL 32610-0374 (United States)

    2006-07-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  7. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2006-01-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  8. Tg.rasH2 Mice and not CByB6F1 Mice Should Be Used for 28-Day Dose Range Finding Studies Prior to 26-Week Tg.rasH2 Carcinogenicity Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Belich, Jessica; Vidmar, Tom J; Elbekai, Reem H; McKeon, Marie; Brown, Caren

    Our recent retrospective analysis of data, collected from 29 Tg.rasH2 mouse carcinogenicity studies, determined how successful the strategy of choosing the high dose for the 26-week studies was based on the estimated maximum tolerated dose (EMTD) derived from earlier 28-day dose range finding (DRF) studies conducted in CByB6F1 mice. Our analysis demonstrated that the high doses applied at EMTD in the 26-week Tg.rasH2 studies failed to detect carcinogenic effects. To investigate why the dose selection process failed in the 26-week carcinogenicity studies, the initial body weights, terminal body weights, body weight gains, food consumption, and mortality from the first 4 weeks of 26-week studies with Tg.rasH2 mice were compared with 28-day DRF studies conducted with CByB6F1 mice. Both the 26-week and the earlier respective 28-day studies were conducted with the exact same vehicle, test article, and similar dose levels. The analysis of our results further emphasizes that the EMTD and subsequent lower doses, determined on the basis of the 28-day studies in CByB6F1 mice, may not be an accurate strategy for selecting appropriate dose levels for the 26-week carcinogenicity studies in Tg.rasH2 mice. Based on the analysis presented in this article, we propose that the Tg.rasH2 mice and not the CByB6F1 mice should be used in future DRF studies. The Tg.rasH2 mice demonstrate more toxicity than the CByB6F1 mice, possibly because of their smaller size compared to CByB6F1 mice. Also, the Tg.rasH2 males appear to be more sensitive than the female Tg.rasH2 mice.

  9. Metabolic Effects of CX3CR1 Deficiency in Diet-Induced Obese Mice.

    Directory of Open Access Journals (Sweden)

    Rachana Shah

    Full Text Available The fractalkine (CX3CL1-CX3CR1 chemokine system is associated with obesity-related inflammation and type 2 diabetes, but data on effects of Cx3cr1 deficiency on metabolic pathways is contradictory. We examined male C57BL/6 Cx3cr1-/- mice on chow and high-fat diet to determine the metabolic effects of Cx3cr1 deficiency. We found no difference in body weight and fat content or feeding and energy expenditure between Cx3cr1-/- and WT mice. Cx3cr1-/- mice had reduced glucose intolerance assessed by intraperitoneal glucose tolerance tests at chow and high-fat fed states, though there was no difference in glucose-stimulated insulin values. Cx3cr1-/- mice also had improved insulin sensitivity at hyperinsulinemic-euglycemic clamp, with higher glucose infusion rate, rate of disposal, and hepatic glucose production suppression compared to WT mice. Enhanced insulin signaling in response to acute intravenous insulin injection was demonstrated in Cx3cr1-/- by increased liver protein levels of phosphorylated AKT and GSK3β proteins. There were no differences in adipose tissue macrophage populations, circulating inflammatory monocytes, adipokines, lipids, or inflammatory markers. In conclusion, we demonstrate a moderate and reproducible protective effect of Cx3cr1 deficiency on glucose intolerance and insulin resistance.

  10. Investigation of equilibrium and kinetics of Cr(VI) adsorption by dried Bacillus cereus using response surface methodology.

    Science.gov (United States)

    Yang, Kai; Zhang, Jing; Yang, Tao; Wang, Hongyu

    2016-01-01

    In this study, response surface methodology (RSM) based on three-variable-five-level central composite rotatable design was used to analyze the effects of combined and individual operating parameters (biomass dose, initial concentration of Cr(VI) and pH) on the Cr(VI) adsorption capacity of dried Bacillus cereus. A quadratic polynomial equation was obtained to predict the adsorbed Cr(VI) amount. Analysis of variance showed that the effect of biomass dose was the key factor in the removal of Cr(VI). The maximum adsorbed Cr(VI) amount (30.93 mg g(-1)) was found at 165.30 mg L(-1), 2.96, and 3.01 g L(-1) for initial Cr(VI) concentration, pH, and biosorbent dosage, respectively. The surface chemical functional groups and microstructure of unloaded and Cr(VI)-loaded dried Bacillus cereus were identified by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), respectively. Besides, the results gained from these studies indicated that Langmuir isotherm and the second-order rate expression were suitable for the removal of Cr(VI) from wastewater. The results revealed RSM was an effective method for optimizing biosorption process, and dried Bacillus cereus had a remarkable performance on the removal of Cr(VI) from wastewater.

  11. Investigation of the γ-decay behavior of 52Cr with the γ 3 setup at HIγS

    Science.gov (United States)

    Wilhelmy, J.; Erbacher, P.; Gayer, U.; Isaak, J.; Löher, B.; Müscher, M.; Pickstone, S. G.; Pietralla, N.; Ries, P.; Romig, C.; Savran, D.; Spieker, M.; Tornow, W.; Werner, V.; Zilges, A.; Zweidinger, M.

    2018-02-01

    The γ-ray strength function is an important input parameter for the calculation of nucleosynthesis processes. To study the dipole response in more detail, the γ-decay behavior of the fp shell nucleus 52Cr was investigated with the high-efficiency γ 3 setup at the High Intensity γ-ray Source facility at TUNL in Durham, USA. The highly intense quasi mono-energetic γ-ray beam allows for excitations selective in multipolarity (J=1 and J=2) and energy. The γ 3 setup is a multi-detector array consisting of HPGe and LaBr3 detectors with high efficiency and enables the measurement of γ-γ coincidences. Experimental results of 52Cr will be presented and discussed in this contribution.

  12. [Cr(N)(acac)2]: A simple chromium nitride complex and its reactivity towards late transition metals

    DEFF Research Database (Denmark)

    Hedegaard, Erik Donovan; Schau-Magnussen, Magnus; Bendix, Jesper

    2011-01-01

    A new simple chromium(V) nitride complex, Cr(N)(acac)2 (1) has been prepared by nitrogen atom transfer. X-ray crystallography shows a short Cr-N bond at 1.5564(11) Å and equatorial Cr-O distances in the range 1.9387(9) – 1.9485(9) Å. 1 reacts as a p-backbonding ligand ......A new simple chromium(V) nitride complex, Cr(N)(acac)2 (1) has been prepared by nitrogen atom transfer. X-ray crystallography shows a short Cr-N bond at 1.5564(11) Å and equatorial Cr-O distances in the range 1.9387(9) – 1.9485(9) Å. 1 reacts as a p-backbonding ligand ...

  13. Intruder dose pathway analysis for the onsite disposal of radioactive wastes: The ONSITE/MAXI1 computer program

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Peloquin, R.A.; Napier, B.A.; Neuder, S.M.

    1987-02-01

    This document summarizes initial efforts to develop human-intrusion scenarios and a modified version of the MAXI computer program for potential use by the NRC in reviewing applications for onsite radioactive waste disposal. Supplement 1 of NUREG/CR-3620 (1986) summarized modifications and improvements to the ONSITE/MAXI1 software package. This document summarizes a modified version of the ONSITE/MAXI1 computer program. This modified version of the computer program operates on a personal computer and permits the user to optionally select radiation dose conversion factors published by the International Commission on Radiological Protection (ICRP) in their Publication No. 30 (ICRP 1979-1982) in place of those published by the ICRP in their Publication No. 2 (ICRP 1959) (as implemented in the previous versions of the ONSITE/MAXI1 computer program). The pathway-to-human models used in the computer program have not been changed from those described previously. Computer listings of the ONSITE/MAXI1 computer program and supporting data bases are included in the appendices of this document

  14. Lifetime exposure to low doses of lead in rats: effect on selected parameters of carbohydrate metabolism.

    Science.gov (United States)

    Nováková, Jaroslava; Lukačínová, Agnesa; Lovásová, Eva; Cimboláková, Iveta; Rácz, Oliver; Ništiar, František

    2015-05-01

    The aim of the study was to assess the effects of exposure to low doses of lead dissolved in drinking water (average daily dose of 2.2 mg kg(-1) day(-1)) on selected carbohydrate metabolism parameters in 20 wistar rats. Animals were divided into two groups - control (C) (group drinking clear water) and experimental group (Pb; group exposed to low doses of lead acetate in a concentration of 100 μmol l(-1) of drinking water). In this study, we studied the biochemical parameters (glucose, haemoglobin (Hb), glycated haemoglobin (HbA1c), lactate dehydrogenase (LDH) and amylase (AMS)) in rat blood. Glucose and Hb concentration and AMS activity decreased, LDH activity increased but HbA1c concentration levels did not change in rats exposed to lead. Our results well documented that lifetime exposure to lead affected carbohydrate metabolism of rats. Some parameters like concentration of Hb as well as activities of AMS and LDH are useful markers of intoxication of rats with lead. For the evaluation of results (e.g. AMS), not only the data at the end of the experiment should be taken into account but also the entire duration of trials (i.e. more time steps) that makes results more objective should be considered. © The Author(s) 2013.

  15. Phase I dose-finding study of S1 in combination with docetaxel and oxaliplatin (DOS) as first-line therapy in patients with advanced gastro-esophageal cancer

    DEFF Research Database (Denmark)

    Weber Vestermark, Lene; Jensen, H. A.; Schoennemann, K. R.

    2015-01-01

    -14) every 3 weeks for a maximum of 6 cycles followed by maintenance therapy with S-1 monotherapy (2 x 30 mg/m2/days 1-14) until progression. Toxicity was evaluated according to NCIC-CTC 4.0. DLT was defined as non-hematological toxicity grade > 3 or febrile neutropenia and evaluated after the first course...... was 67-years (49-75), median performance status was 1 (0-1). None of 3 patients at dose level 1 and 2 developed DLT. At dose level 3, 2/4 pts developed DLT (febrile neutropenia and febrile neutropenia with diarrhoea) and further inclusion at dose level 3 was halted. Five further patients at dose level 2...

  16. Effect of HTGR helium on fatigue and creep properties of 2 1/4Cr-1Mo steel

    International Nuclear Information System (INIS)

    Kurumaji, T.; Yamazaki, H.; Kudo, A.

    1982-01-01

    Low cycle fatigue and creep tests have been carried out on 2 1/4Cr-1Mo steel (candidate steel for VHTR reactor pressure vessel) in helium environment containing 200 approx. 300 μatm of H 2 , 100 approx. 150 μatm CO, 7 approx. 10 μatm CH 4 , 7 approx. 10 μatm CO 2 and 1 μatm H 2 O (JAERI B Helium). Fatigue life in helium environment was longer than that in air at 450 0 C. This results can be explained by supposing that oxidation at the crack tip causes the wedge effect to promote crack propagation in air. On the otherhand, creep rupture strength showed no significant difference in both helium and air. Equivalent creep rupture strength in both helium and air may be due to the fact that detrimental internal oxidation and carburization or decarburization hardly occur at 400 approx. 450 0 C

  17. Phase I/II trial of concurrent use of S-1 and radiation therapy for T2 glottic cancer

    International Nuclear Information System (INIS)

    Nakayama, Meijin; Hayakawa, Kazushige; Okamoto, Makito; Niibe, Yuzuru; Ishiyama, Hiromichi; Kotani, Shouko

    2010-01-01

    A Phase I/II study of S-1 combined radiation therapy was conducted in patients with Stage II (T2N0) glottic cancer. The purpose of the Phase I study was to identify the maximum tolerated dose, the recommended dose and the dose limiting toxicity. The objectives in the phase II study were to estimate the local control and the overall survival, and the incidence of adverse events. In Phase I, S-1 was administered orally in a split-course fashion as two doses of 40 mg/m 2 , for a total daily dose of 80 mg/m 2 . The course involved a 2-week rest after a 2-week administration (Level 1) and a 1-week rest after a 3-week administration (Level 2). Radiation therapy was administered in 2-Gy daily (total 60-Gy) standard fractionation. Seven patients were enrolled in the Phase I, and 19 in the Phase II study. Mucositis was the most common toxicity encountered. All 26 patients completed radiation therapy without delay. The overall response rate was 100% (26/26) with all patients showing a complete response. One patient developed a local recurrence 28 months after the treatment. The 3-year local control and overall survival rates were 94.7 and 85.4%, respectively (limited to 22 patients from Level 2). The use of S-1 at 80 mg/m 2 per day in a split-course with 1-week rest during the course of radiation therapy was safe and effective for Stage II glottic cancer. The treatment strategy employing orally available S-1 proved to be beneficial over the conventional injection of antitumor agents for maintaining the patients' quality of life. (author)

  18. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium.

    Science.gov (United States)

    Zifodya, Jackson M; Challens, Cameron H C; Hsieh, Wen-Long

    2016-06-01

    When implementing Acuros XB (AXB) as a substitute for anisotropic analytic algorithm (AAA) in the Eclipse Treatment Planning System, one is faced with a dilemma of reporting either dose to medium, AXB-Dm or dose to water, AXB-Dw. To assist with decision making on selecting either AXB-Dm or AXB-Dw for dose reporting, a retrospective study of treated patients for head & neck (H&N), prostate, breast and lung is presented. Ten patients, previously treated using AAA plans, were selected for each site and re-planned with AXB-Dm and AXB-Dw. Re-planning was done with fixed monitor units (MU) as well as non-fixed MUs. Dose volume histograms (DVH) of targets and organs at risk (OAR), were analyzed in conjunction with ICRU-83 recommended dose reporting metrics. Additionally, comparisons of plan homogeneity indices (HI) and MUs were done to further highlight the differences between the algorithms. Results showed that, on average AAA overestimated dose to the target volume and OARs by less than 2.0 %. Comparisons between AXB-Dw and AXB-Dm, for all sites, also showed overall dose differences to be small (135 % of prescription dose) for target volumes with high density materials. Homogeneity indices showed that AAA planning and optimization templates would need to be adjusted only for the H&N and Lung sites. MU comparison showed insignificant differences between AXB-Dw relative to AAA and between AXB-Dw relative to AXB-Dm. However AXB-Dm MUs relative to AAA, showed an average difference of about 1.3 % signifying an underdosage by AAA. In conclusion, when dose is reported as AXB-Dw, the effect that high density structures in the PTV has on the dose distribution should be carefully considered. As the results show overall small dose differences between the algorithms, when transitioning from AAA to AXB, no significant change to existing prescription protocols is expected. As most of the clinical experience is dose-to-water based and calibration protocols and clinical trials are

  19. Creep-rupture behavior of 2-1/4 Cr-1 Mo steel, Alloy 800H and Hastelloy Alloy X in a simulated HTGR helium environment

    International Nuclear Information System (INIS)

    Lai, G.Y.; Wolwowicz, R.J.

    1979-12-01

    Creep-rupture testing was conducted on 1 1/4 Cr-1 Mo steel, Alloy 800H and Hastelloy Alloy X in flowing helium containing nominal concentration of following gases: 1500 μatm H 2 , 450 μatm CO, 50 μatm CH 4 , 50 μatm H 2 O and 5 μatm CO 2 . This environment is believed to represent maximum permissible levels of impurities in the primary coolant for the steam-cycle system of a high-temperature gas-cooled reactor (HTGR) when it is operating continuously with a water and/or steam leak at technical specification limits. Two or three heats of material for each alloy were investigated. Tests were conducted at 482 0 C and 760 0 C (1200 0 F and 1400 0 F) for Alloy 800H, and at 760 0 C and 871 0 C (1400 0 F and 1600 0 F) for Hastelloy Alloy X for times up to 10,000 h. Selected tests were performed on same heat of material in both air and helium environments to make a direct comparison of creep-rupture behaviors between two environments. Metallurgical evaluation was performed on selected post test specimens with respect to gas-metal interactions which included oxidation, carburization and/or decarburization. Correlation between gaseous corrosion and creep-rupture behavior was attempted. Limited tests were also performed to investigate the specimen size effects on creep-rupture behavior in the helium environment

  20. High Rate Deposition of Thick CrN and Cr2N Coatings Using Modulated Pulse Power (MPP) Magnetron Sputtering

    Science.gov (United States)

    2010-12-01

    AISI 440C steel using a microtribometer (Center for Tribology , Inc) in an ambient air atmosphere without a lubricant (a relative humidity of 251...that the CTE for the 440 C stainless steel substrate is 10.2x10 -6 o C -1 [37],while the CTE values for the CrN and Cr2N coatings are 2.3x10 -6...increased scratch critical load (Fig. 12) as the coating thickness was increased. Since the coating is much harder than the stainless steel substrate

  1. Exploratory survey of image quality on CR digital mammography imaging systems in Mexico

    International Nuclear Information System (INIS)

    Gaona, E.; Rivera, T.; Arreola, M.; Franco, J.; Molina, N.; Alvarez, B.; Azorín, C.G.; Casian, G.

    2014-01-01

    The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation. - Highlights: • Radiation dose in CR digital mammography (CRDM) systems was determined. • Image quality related with dose in CR digital mammography (CRDM) systems was analysed. • Image processing artefacts were observed and correlated with dose. • Measured entrance dose by TL phosphors could be good parameter for radiation protection optimization in patient

  2. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  3. Preparation of (S)-1-Halo-2-octanols Using Ionic Liquids and Biocatalysts.

    Science.gov (United States)

    Oromí-Farrús, Mireia; Eras, Jordi; Sala, Núria; Torres, Mercè; Canela, Ramon

    2009-10-23

    Preparation of (S)-1-chloro-2-octanol and (S)-1-bromo-2-octanol was carried out by the enzymatic hydrolysis of halohydrin palmitates using biocatalysts. Halohydrin palmitates were prepared by various methods from palmitic acid and 1,2-octanediol. A tandem hydrolysis was carried out using lipases from Candida antarctica (Novozym 435), Rhizomucor miehei (Lipozyme IM), and "resting cells" from a Rhizopus oryzae strain that was not mycotoxigenic. The influence of the enzyme and the reaction medium on the selective hydrolysis of isomeric mixtures of halohydrin esters is described. Novozym 435 allowed preparation of (S)-1-chloro-2-octanol and (S)-1-bromo-2-octanol after 1-3 h of reaction at 40 degrees C in [BMIM][PF(6)].

  4. Site-specific functionalization for chemical speciation of Cr(III) and Cr(VI) using polyaniline impregnated nanocellulose composite: equilibrium, kinetic, and thermodynamic modeling

    Science.gov (United States)

    Jain, Priyanka; Varshney, Shilpa; Srivastava, Shalini

    2017-07-01

    Site-specific functionalizations are the emergent attention for the enhancement of sorption latent of heavy metals. Limited chemistry has been applied for the fabrication of diafunctionalized materials having potential to tether both environmentally stable oxidation states of chromium (Cr(III) and Cr(VI). Polyaniline impregnated nanocellulose composite (PANI-NCC) has been fabricated using click chemistry and explored for the removal of Cr(III) and Cr(VI) from hydrological environment. The structure, stability, morphology, particle size, surface area, hydrophilicity, and porosity of fabricated PANI-NCC were characterized comprehensively using analytical techniques and mathematical tools. The maximum sorption performance of PANI-NCC was procured for (Cr(III): 47.06 mg g-1; 94.12 %) and (Cr(VI): 48.92 mg g-1; 97.84 %) by equilibrating 0.5 g sorbent dose with 1000 mL of 25 mg L-1 chromium conc. at pH 6.5 and 2.5 for Cr(III) and Cr(VI), respectively. The sorption data showed a best fit to the Langmuir isotherm and pseudo-second-order kinetic model. The negative value of Δ G° (-8.59 and -11.16 kJ mol-1) and Δ H° (66.46 × 10-1 and 17.84 × 10-1 kJ mol-1), and positive value of Δ S° (26.66 and 31.46 J mol-1K-1) for Cr(III) and Cr(VI), respectively, reflect the spontaneous, feasibility, and exothermic nature of the sorption process. The application of fabricated PANI-NCC for removing both the forms of chromium in the presence of other heavy metals was also tested at laboratory and industrial waste water regime. These findings open up new avenues in the row of high performance, scalable, and economic nanobiomaterial for the remediation of both forms of chromium from water streams.

  5. Dose of rocuronium for rapid tracheal intubation following remifentanil 2 μg kg-1 and propofol 2 mg kg-1.

    Science.gov (United States)

    Oh, Ah-Young; Cho, Suk-Ju; Seo, Kwang-Suk; Ryu, Jung-Hee; Han, Sung-Hee; Hwang, Jung-Won

    2013-09-01

    Full relaxation is not mandatory for successful tracheal intubation. We tried to find the dose of rocuronium that gave acceptable intubation conditions in a rapid sequence intubation with remifentanil and propofol. A dose-finding study of rocuronium using a modified Dixon's up-and-down method. A single tertiary care teaching hospital. Patients undergoing elective surgery under general anaesthesia. After premedication with midazolam and glycopyrrolate, anaesthesia was induced using remifentanil 2 μg kg and propofol 2 mg kg, and a predetermined dose of rocuronium was administered. The dose of rocuronium was determined by a modified Dixon's up-and-down method starting from 0.8 mg kg with an interval of 0.1 or 0.05 mg kg. Intubation was performed 60 s after the start of the rocuronium injection. Intubation conditions were graded as excellent, good or poor. Excellent or good were regarded as clinically acceptable. A dose of rocuronium needed for acceptable intubation condition in 50% of patients (ED50) during rapid tracheal intubation after induction of anaesthesia with remifentanil and propofol. Twenty-eight patients were enrolled to obtain six crossovers. The ED50 of rocuronium was 0.20 mg kg (95% confidence interval, CI 0.17 to 0.23 mg kg) by a modified Dixon's up-and-down method. After induction of anaesthesia with remifentanil 2 μg kg and propofol 2 mg kg, the ED50 of rocuronium for acceptable intubation condition was 0.20 mg kg (95% CI, 0.17 to 0.23 mg kg) for rapid sequence intubation. Thus, we recommend that the intubation dose should be 0.8 mg kg. Clinical trial registration KCT0000094.

  6. Magnetic interaction reversal in watermelon nanostructured Cr-doped Fe nanoclusters

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Maninder; Dai, Qilin; Bowden, Mark; Engelhard, Mark; Wu, Yaqiao; Tang, Jinke; Qiang, You

    2013-01-01

    Cr-doped core-shell Fe/Fe-oxide nanoclusters (NCs) were synthesized at varied atomic percentages of Cr from 0 at. % to 8 at. %. The low concentrations of Cr (<10 at. %) were selected in order to inhibit the complete conversion of the Fe-oxide shell to Cr2O3 and the Fe core to FeCr alloy. The magnetic interaction in Fe/Fe-oxide NCs (rv25 nm) can be controlled by antiferromagnetic Cr-dopant. We report the origin of r-FeCr phase at very low Cr concentration (2 at. %) unlike in previous studies, and the interaction reversal from dipolar to exchange interaction in watermelon-like Cr-doped core-shell NCs. The giant magnetoresistance (GMR) effect,1,2 where an antiferromagnetic (AFM) exchange coupling exists between two ferromagnetic (FM) layers separated by a certain type of magnetic or non-magnetic spacer,3 has significant potential for application in the magnetic recording industry. Soon after the discovery of the GMR, the magnetic properties of multilayer systems (FeCr) became a subject of intensive study. The application of bulk iron-chromium (Fe-Cr) alloys has been of great interest, as these alloys exhibit favorable prop- erties including corrosion resistance, high strength, hardness, low oxidation rate, and strength retention at elevated temper- ature. However, the structural and magnetic properties of Cr-doped Fe nanoclusters (NCs) have not been investigated in-depth. Of all NCs, Fe-based clusters have unique magnetic properties as well as favorable catalytic characteristics in reactivity, selectivity, and durability.4 The incorporation of dopant of varied type and concentration in Fe can modify its chemical ordering, thereby optimizing its electrical, optical, and magnetic properties and opening up many new applications. The substitution of an Fe atom (1.24 A°) by a Cr atom (1.25 A° ) can easily modify the magnetic properties, since (i) the curie temperature (Tc ) of Fe is 1043 K, while Cr is an itinerant AFM with a bulk Neel temperature TN =311 K, and (ii) Fe

  7. Dual Selectivity Expressed in [2+2+1] Dynamic Clipping of Unsymmetrical [2]Catenanes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi

    2010-06-11

    A {pi}-templated dynamic [2+2+1] clipping protocol is established for the synthesis of [2]catenanes from two parts dialdehyde, two parts diamine and one part tetracationic cyclophane. It is further diversified for the selective formation of an unsymmetrical [2]catenane showing great translational selectivity by employing two different dialdehydes in a one-pot reaction. The dual selectivity and the dynamic nature are verified by {sup 1}H NMR spectroscopy, X-ray single crystal structural studies and exchange experiments.

  8. Handbook of selected organ doses for projections common in pediatric radiology

    International Nuclear Information System (INIS)

    Rosenstein, M.; Beck, T.J.; Warner, G.G.

    1979-05-01

    This handbook contains data from which absorbed dose (mrad) to selected organs can be estimated for common projections in pediatric radiology. The organ doses are for three reference patients: a newborn (0 to 6 months), a 1-year old child, and a 5-year old child. One intent of the handbook is to permit the user to evaluate the effect on organ dose to these reference pediatric patients as a function of certain changes in technical parameters used in or among facilities. A second intent is to permit a comparison to be made of organ doses as a function of age. This comparison can be extended to a reference adult by referring to the previous Handbook of Selected Organ Doses fo Projections Common in Diagnostic Radiology, FDA 76-8031. Assignment of organ doses to individual pediatric patients using the Handbook data is not recommended unless the physical characteristics of the patient closely correlate with one of the three reference pediatric patients given in Appendix A

  9. Magnetoelectric effect in Cr2O3 thin films

    Science.gov (United States)

    He, Xi; Wang, Yi; Sahoo, Sarbeswar; Binek, Christian

    2008-03-01

    Magnetoelectric materials experienced a recent revival as promising components of novel spintronic devices [1, 2, 3]. Since the magnetoelectric (ME) effect is relativistically small in traditional antiferromagnetic compounds like Cr2O3 (max. αzz 4ps/m ) and also cross- coupling between ferroic order parameters is typically small in the modern multiferroics, it is a challenge to electrically induce sufficient magnetization required for the envisioned device applications. A straightforward approach is to increase the electric field at constant voltage by reducing the thickness of the ME material to thin films of a few nm. Since magnetism is known to be affected by geometrical confinement thickness dependence of the ME effect in thin film Cr2O3 is expected. We grow (111) textured Cr2O3 films with various thicknesses below 500 nm and study the ME effect for various ME annealing conditions as a function of temperature with the help of Kerr-magnetometry. [1] P. Borisov et al. Phys. Rev. Lett. 94, 117203 (2005). [2] Ch. Binek, B.Doudin, J. Phys. Condens. Matter 17, L39 (2005). [3] R. Ramesh and Nicola A. Spaldin 2007 Nature Materials 6 21.

  10. Cerebral Cortex Regions Selectively Vulnerable to Radiation Dose-Dependent Atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Seibert, Tyler M.; Karunamuni, Roshan; Kaifi, Samar; Burkeen, Jeffrey; Connor, Michael [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Krishnan, Anitha Priya; White, Nathan S.; Farid, Nikdokht; Bartsch, Hauke [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Murzin, Vyacheslav [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Nguyen, Tanya T. [Department of Psychiatry, University of California, San Diego, La Jolla, California (United States); Moiseenko, Vitali [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Brewer, James B. [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Department of Neurosciences, University of California, San Diego, La Jolla, California (United States); McDonald, Carrie R. [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Department of Psychiatry, University of California, San Diego, La Jolla, California (United States); Dale, Anders M. [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Department of Psychiatry, University of California, San Diego, La Jolla, California (United States); Department of Neurosciences, University of California, San Diego, La Jolla, California (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States)

    2017-04-01

    Purpose and Objectives: Neurologic deficits after brain radiation therapy (RT) typically involve decline in higher-order cognitive functions such as attention and memory rather than sensory defects or paralysis. We sought to determine whether areas of the cortex critical to cognition are selectively vulnerable to radiation dose-dependent atrophy. Methods and Materials: We measured change in cortical thickness in 54 primary brain tumor patients who underwent fractionated, partial brain RT. The study patients underwent high-resolution, volumetric magnetic resonance imaging (T1-weighted; T2 fluid-attenuated inversion recovery, FLAIR) before RT and 1 year afterward. Semiautomated software was used to segment anatomic regions of the cerebral cortex for each patient. Cortical thickness was measured for each region before RT and 1 year afterward. Two higher-order cortical regions of interest (ROIs) were tested for association between radiation dose and cortical thinning: entorhinal (memory) and inferior parietal (attention/memory). For comparison, 2 primary cortex ROIs were also tested: pericalcarine (vision) and paracentral lobule (somatosensory/motor). Linear mixed-effects analyses were used to test all other cortical regions for significant radiation dose-dependent thickness change. Statistical significance was set at α = 0.05 using 2-tailed tests. Results: Cortical atrophy was significantly associated with radiation dose in the entorhinal (P=.01) and inferior parietal ROIs (P=.02). By contrast, no significant radiation dose-dependent effect was found in the primary cortex ROIs (pericalcarine and paracentral lobule). In the whole-cortex analysis, 9 regions showed significant radiation dose-dependent atrophy, including areas responsible for memory, attention, and executive function (P≤.002). Conclusions: Areas of cerebral cortex important for higher-order cognition may be most vulnerable to radiation-related atrophy. This is consistent with clinical observations

  11. Cerebral Cortex Regions Selectively Vulnerable to Radiation Dose-Dependent Atrophy

    International Nuclear Information System (INIS)

    Seibert, Tyler M.; Karunamuni, Roshan; Kaifi, Samar; Burkeen, Jeffrey; Connor, Michael; Krishnan, Anitha Priya; White, Nathan S.; Farid, Nikdokht; Bartsch, Hauke; Murzin, Vyacheslav; Nguyen, Tanya T.; Moiseenko, Vitali; Brewer, James B.; McDonald, Carrie R.; Dale, Anders M.; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose and Objectives: Neurologic deficits after brain radiation therapy (RT) typically involve decline in higher-order cognitive functions such as attention and memory rather than sensory defects or paralysis. We sought to determine whether areas of the cortex critical to cognition are selectively vulnerable to radiation dose-dependent atrophy. Methods and Materials: We measured change in cortical thickness in 54 primary brain tumor patients who underwent fractionated, partial brain RT. The study patients underwent high-resolution, volumetric magnetic resonance imaging (T1-weighted; T2 fluid-attenuated inversion recovery, FLAIR) before RT and 1 year afterward. Semiautomated software was used to segment anatomic regions of the cerebral cortex for each patient. Cortical thickness was measured for each region before RT and 1 year afterward. Two higher-order cortical regions of interest (ROIs) were tested for association between radiation dose and cortical thinning: entorhinal (memory) and inferior parietal (attention/memory). For comparison, 2 primary cortex ROIs were also tested: pericalcarine (vision) and paracentral lobule (somatosensory/motor). Linear mixed-effects analyses were used to test all other cortical regions for significant radiation dose-dependent thickness change. Statistical significance was set at α = 0.05 using 2-tailed tests. Results: Cortical atrophy was significantly associated with radiation dose in the entorhinal (P=.01) and inferior parietal ROIs (P=.02). By contrast, no significant radiation dose-dependent effect was found in the primary cortex ROIs (pericalcarine and paracentral lobule). In the whole-cortex analysis, 9 regions showed significant radiation dose-dependent atrophy, including areas responsible for memory, attention, and executive function (P≤.002). Conclusions: Areas of cerebral cortex important for higher-order cognition may be most vulnerable to radiation-related atrophy. This is consistent with clinical observations

  12. Electron impact excitation-autoionisation of the (2s2)1S, (2p2)1D and (2s2p)1P autoionising states of helium

    International Nuclear Information System (INIS)

    Samardzic, O.; Hurn, J.A.; Weigold, E.; Brunger, M.J.

    1994-01-01

    The electron impact excitation of the (2s 2 ) 1 S, (2p 2 ) 1 D and (2s2p) 1 P autoionising states of helium and their subsequent radiationless decay was studied by observation of the ejected electrons. The present work was carried out at an incident energy of 94.6 eV and for ejected electron scattering angles in the range 25-135 deg C. The lineshapes observed in the present ejected electron spectra are analysed using the Shore-Balashov parametrisation. As part of the analysis procedure, numerically rigorous confidence limits were determined for the derived parameters. No previous experimental or theoretical work has been undertaken at the incident energy of the present investigation but, where possible, the resulting parameters are qualitatively compared against the 80 eV results of other experiments and theory. 37 refs., 4 figs

  13. Selective Flow Injection Analysis of Ultra-trace Amounts of Cr(VI), Preconcentration of It by Solvent Extraction, and Determination by Electrothermal Atomic Absorption Spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Sturup, Stefan; Spliid, Henrik

    1999-01-01

    (IBMK). The Cr(VI) is complexed by reaction with ammonium pyrrolidine dithiocarbamate (APDC), and the non-charged Cr(VI)-PDC chelate formed is extracted into IBMK in a knotted reactor made from PTFE tubing. The organic extractant is separated from the aqueous phase by a gravity phase separator......(VI) was achieved after preconcentration for 99 s at a sample flow rate of 5.5 ml min-1, as compared to direct introduction of 55 mul of sample, yielding a detection limit (3sigma) of 3.3 ng l-1. The sampling frequency was 24.2 samples h-1. The proposed method was successfully evaluated by analyzing a NIST Cr...

  14. Adaptive response of spermatogenic cell apoptosis selectively induced by low dose X-ray irradiation in mice

    International Nuclear Information System (INIS)

    Liu Guangwei; Dong Lihua; Liu Yang; Lv Zhe; Liu Shuchun; Gong Shouliang

    2003-01-01

    Objective: The adaptive response of spermatogenic cell apoptosis induced by whole-body X-ray irradiation at low doses was studied in mice. Methods: Kunming male mice were irradiated with an inductive dose (D1:75 mGy) and/or a challenging dose (D2:1.0, 2.0 or 3.0 Gy). Different kinds of spermatogenic cells were separated using density gradient centrifugation and their apoptotic percentages were analysed using flow cytometry (FCM). Results: When the mice were irradiated with D1 6 h before irradiation with D2, the apoptotic percentages of the spermatogonia and spermatocytes declined rapidly as compared with those in the groups irradiated with D2 only, and those of spermatids and spermatozoa showed no significant changes. When the interval times between D1 and D2 was 3, 6, 12 or 24 h, the apoptotic percentages in spermatogonia and spermatocytes reduced early, significantly and continued for a longer duration after smaller D2(1.0 and 2.0 Gy) irradiation, while the apoptotic percentages did not change after larger D2(3.0 Gy) irradiation. Conclusion: The adaptive response of apoptosis in spermatogonia and spermatocytes could be selectively induced by low dose X-ray irradiation. The adaptive response could be closely related to the D2 dose and interval time between D1 and D2

  15. Competition of the Peierls relief and structural defects in damping the domain walls in [Mn left brace (R/S)-pn right brace]2[Mn left brace(R/S)-pn right brace2(H2O)][Cr(CN)6]2 ferrimagnet

    International Nuclear Information System (INIS)

    Talantsev, A.D.; Kollak, O.V.; Kirman, M.V.; Morgunov, R.B.

    2015-01-01

    The [ [Mn left brace (R/S)-pn right brace] 2 [Mn left brace(R/S)-pn right brace 2 (H 2 O)][Cr(CN) 6 ] 2 molecular ferrimagnet exhibits an inverse sequence of changes in the domain wall motion regimes with increasing temperature in alternative magnetic field of 0.04-1400 Hz frequency. Initiation of the relaxation regime on the background of creep indicates that there are two different systems of the domain walls damping. The threshold amplitude of the alternative magnetic field corresponds to the Peierls relief contribution to the domain wall dynamics as well as the defect contribution usually considered.

  16. A highly selective sorbent for removal of Cr(VI) from aqueous solutions based on Fe₃O₄/poly(methyl methacrylate) grafted Tragacanth gum nanocomposite: optimization by experimental design.

    Science.gov (United States)

    Sadeghi, Susan; Rad, Fatemeh Alavi; Moghaddam, Ali Zeraatkar

    2014-12-01

    In this work, poly(methyl methacrylate) grafted Tragacanth gum modified Fe3O4 magnetic nanoparticles (P(MMA)-g-TG-MNs) were developed for the selective removal of Cr(VI) species from aqueous solutions in the presence of Cr(III). The sorbent was characterized by Fourier transform infrared (FTIR) spectroscopy, transmission electron microscopy (TEM), a vibrating sample magnetometer (VSM), and thermo-gravimetric analysis (TGA). A screening study on operational variables was performed using a two-level full factorial design. Based on the analysis of variance (ANOVA) with 95% confidence limit, the significant variables were found. The central composite design (CCD) has also been employed for statistical modeling and analysis of the effects and interactions of significant variables dealing with the Cr(VI) uptake process by the developed sorbent. The predicted optimal conditions were situated at a pH of 5.5, contact time of 3.4 h, and 3.0 g L(-1) dose. The Langmuir, Freundlich, and Temkin isotherm models were used to describe the equilibrium sorption of Cr(VI) by the absorbent, and the Langmuir isotherm showed the best concordance as an equilibrium model. The adsorption process was followed by a pseudo-second-order kinetic model. Thermodynamic investigations showed that the biosorption process was spontaneous and exothermic. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Selective coupling of the S1P3 receptor subtype to S1P-mediated RhoA activation and cardioprotection.

    Science.gov (United States)

    Yung, Bryan S; Brand, Cameron S; Xiang, Sunny Y; Gray, Charles B B; Means, Christopher K; Rosen, Hugh; Chun, Jerold; Purcell, Nicole H; Brown, Joan Heller; Miyamoto, Shigeki

    2017-02-01

    Sphingosine-1-phosphate (S1P), a bioactive lysophospholipid, is generated and released at sites of tissue injury in the heart and can act on S1P 1 , S1P 2 , and S1P 3 receptor subtypes to affect cardiovascular responses. We established that S1P causes little phosphoinositide hydrolysis and does not induce hypertrophy indicating that it does not cause receptor coupling to G q . We previously demonstrated that S1P confers cardioprotection against ischemia/reperfusion by activating RhoA and its downstream effector PKD. The S1P receptor subtypes and G proteins that regulate RhoA activation and downstream responses in the heart have not been determined. Using siRNA or pertussis toxin to inhibit different G proteins in NRVMs we established that S1P regulates RhoA activation through Gα 13 but not Gα 12 , Gα q , or Gα i . Knockdown of the three major S1P receptors using siRNA demonstrated a requirement for S1P 3 in RhoA activation and subsequent phosphorylation of PKD, and this was confirmed in studies using isolated hearts from S1P 3 knockout (KO) mice. S1P treatment reduced infarct size induced by ischemia/reperfusion in Langendorff perfused wild-type (WT) hearts and this protection was abolished in the S1P 3 KO mouse heart. CYM-51736, an S1P 3 -specific agonist, also decreased infarct size after ischemia/reperfusion to a degree similar to that achieved by S1P. The finding that S1P 3 receptor- and Gα 13 -mediated RhoA activation is responsible for protection against ischemia/reperfusion suggests that selective targeting of S1P 3 receptors could provide therapeutic benefits in ischemic heart disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Exploring selectivity requirements for COX-2 versus COX-1 binding of 2-(5-phenyl-pyrazol-1-yl)-5-methanesulfonylpyridines using topological and physico-chemical parameters.

    Science.gov (United States)

    Chakraborty, Santanu; Sengupta, Chandana; Roy, Kunal

    2005-04-01

    Considering the current need for development of selective cyclooxygenase-2 (COX-2) inhibitors, an attempt has been made to explore physico-chemical requirements of 2-(5-phenyl-pyrazol-1-yl)-5-methanesulfonylpyridines for binding with COX-1 and COX-2 enzyme subtypes and also to explore the selectivity requirements. In this study, E-states of different common atoms of the molecules (calculated according to Kier & Hall), first order valence connectivity and physicochemical parameters (hydrophobicity pi, Hammett sigma and molar refractivity MR of different ring substituents) were used as independent variables along with suitable dummy parameters in the stepwise regression method. The best equation describing COX-1 binding affinity [n = 25, Q2 = 0.606, R(a)2 = 0.702, R2 = 0.752, R = 0.867, s = 0.447, F = 15.2 (df 4, 20)] suggests that the COX-1 binding affinity increases in the presence of a halogen substituent at R1 position and a p-alkoxy or p-methylthio substituent at R2 position. Furthermore, a difluoromethyl group is preferred over a trifluoromethyl group at R position for the COX-1 binding. The best equation describing COX-2 binding affinity [n = 32, Q2 = 0.622, R(a)2= 0.692, R2 = 0.732, R = 0.856, s = 0.265, F = 18.4 (df 4, 27)] shows that the COX-2 binding affinity increases with the presence of a halogen substituent at R1 position and increase of size of R2 substituents. However, it decreases in case of simultaneous presence of 3-chloro and 4-methoxy groups on the phenyl nucleus and in the presence of highly lipophilic R2 substituents. The best selectivity relation [n = 25, Q2 = 0.455, R(a)2 = 0.605, R2 = 0.670, R = 0.819, s = 0.423, F = 10.2 (df 4, 20)] suggests that the COX-2 selectivity decreases in the presence of p-alkoxy group and electron-withdrawing para substituents at R2 position. Again, a trifluoro group is conductive for the selectivity instead of a difluoromethyl group at R position. Furthermore, branching may also play significant role in

  19. Effect of Heat Treatment on the Properties of CoCrMo Alloy Manufactured by Selective Laser Melting

    Science.gov (United States)

    Guoqing, Zhang; Junxin, Li; Xiaoyu, Zhou; Jin, Li; Anmin, Wang

    2018-05-01

    To obtain medical implants with better mechanical properties, it is necessary to conduct studies on the heat treatment process of the selective laser melting (SLM) manufacturing parts. The differential scanning calorimetry method was used to study the heat treatment process of the phase transition of SLM CoCrMo alloy parts. The tensile properties were tested with a tensile test machine, the quantity of carbide precipitated after heat treatment was measured by energy-dispersive x-ray spectroscopy, and the tensile fracture morphology of the parts was investigated using SEM. The obtained results were: Mechanical properties in terms of elongation and tensile strength of CoCrMo alloy manufactured by SLM that had been heat-treated at 1200 °C for 2 h followed by cooling with water were not only higher than the national standard but also higher than the experimental results of the same batch of castings. The mechanism of fracture of parts manufactured by SLM without heat treatment was brittle fracture, whereas parts which had been heat-treated at 1200 °C for 2 h combined with water cooling and at 1200 °C for 1 h with furnace cooling suffered ductile fracture. This study provides the basis for defining the applications for which CoCrMo alloys manufactured by SLM are suitable within the field of medical implants.

  20. Morphology, deformation, and defect structures of TiCr2 in Ti-Cr alloys

    International Nuclear Information System (INIS)

    Chen, K.C.; Allen, S.M.; Livingston, J.D.

    1992-01-01

    The morphologies and defect structures of TiCr 2 in several Ti-Cr alloys have been examined by optical metallography, x-ray diffraction, and transmission electron microscopy (TEM), in order to explore the room-temperature deformability of the Laves phase TiCr 2 . The morphology of the Laves phase was found to be dependent upon alloy composition and annealing temperature. Samples deformed by compression have also been studied using TEM. Comparisons of microstructures before and after deformation suggest an increase in twin, stacking fault, and dislocation density within the Laves phase, indicating some but not extensive room-temperature deformability

  1. A fetal whole ovarian culture model for the evaluation of CrVI-induced developmental toxicity during germ cell nest breakdown

    Energy Technology Data Exchange (ETDEWEB)

    Stanley, Jone A.; Arosh, Joe A.; Burghardt, Robert C.; Banu, Sakhila K., E-mail: skbanu@cvm.tamu.edu

    2015-11-15

    Prenatal exposure to endocrine disrupting chemicals (EDCs), including bisphenol A, dioxin, pesticides, and cigarette smoke, has been linked to several ovarian diseases such as premature ovarian failure (POF) and early menopause in women. Hexavalent chromium (CrVI), one of the more toxic heavy metals, is widely used in more than 50 industries. As one of the world's leading producers of Cr compounds, the U.S. is facing growing challenges in protecting human health against adverse effects of CrVI. Our recent findings demonstrated that in vivo CrVI exposure during gestational period caused POF in F1 offspring. Our current research focus is three-fold: (i) to identify the effect of CrVI on critical windows of great vulnerability of fetal ovarian development; (ii) to understand the molecular mechanism of CrVI-induced POF; (iii) to identify potential intervention strategies to mitigate or inhibit CrVI effects. In order to accomplish these goals we used a fetal whole ovarian culture system. Fetuses were removed from the normal pregnant rats on gestational day 13.5. Fetal ovaries were cultured in vitro for 12 days, and treated with or without 0.1 ppm potassium dichromate (CrVI) from culture day 2–8, which recapitulated embryonic day 14.5–20.5, in vivo. Results showed that CrVI increased germ cell/oocyte apoptosis by increasing caspase 3, BAX, p53 and PUMA; decreasing BCL2, BMP15, GDF9 and cKIT; and altering cell cycle regulatory genes and proteins. This model system may serve as a potential tool for high throughput testing of various drugs and/or EDCs in particular to assess developmental toxicity of the ovary. - Highlights: • CrVI (0.1 ppm, a regulatory dose) increased germ cell apoptosis of fetal ovaries. • CrVI (0.1 ppm) increased pro-apoptotic proteins. • CrVI (0.1 ppm) decreased cyclins and CDK1 and cell survival proteins. • CrVI (0.1 ppm) increased oxidative stress during fetal ovarian development. • We propose fetal ovarian culture model for high

  2. ABILITY OF Phanerochaete chrysosporium AND Trametes versicolor TO REMOVE Zn2+, Cr3+, Pb2+ METAL IONS

    Directory of Open Access Journals (Sweden)

    Josué Solís Pacheco

    2015-07-01

    Full Text Available The use of fungal biomass as an alternative for removing heavy metals has become increasingly important in recent years, replacing conventional methods based on chemical physical processes. In this study, we evaluated the biosorption of Zn2+, Cr3+ and Pb2+, which were analyzed to determine their effect on growth kinetic parameters of Phanerochaete chrysosporium strain ATCC 32629 and Trametes versicolor ATCC 1267. Growth kinetics were performed in four liquid culture media: 1 Yeast Nitrogen Base (YNB used as control, 2 YNB medium plus Pb2+ (0.25, 1 and 2 mg L-1, 3 YNB medium plus Zn2+ (5, 10 and 20 mg L-1 and 4 YNB medium plus Cr3+ (0.5, 1 and 2 mg L-1. The flasks were incubated at 25 °C with shaking at 150 rpm. Metal concentrations were determined by inductively coupled plasma atomic emission spectroscopy (ICP-AES with prior acid digestion of the sample. The results demonstrated that Phanerochaete chrysosporium ATCC 32629 and Trametes versicolor ATCC 12679 are able to grow in the culture medium with Pb2+, Zn2+ and Cr3+ ions at different concentrations. However, P. chrysosporium ATCC 32629 showed greater adaptability and ability to adsorb Cr3+ in the culture medium at concentrations of 0.5 and 1 mg L-1, whereas T. versicolor ATCC 12679 was capable of Pb2+ biosorption at concentrations of 0.25, 1 and 2 mg L-1.

  3. Layered B-site cation ordering: A key factor in ferrimagnetism of Y{sub 2}MnCrO{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Lin [Department of Physics, University of Science and Technology of China, Hefei, Anhui (China); Yang, Lei [Collaborative Innovation Center for Magnetoelectric Industry, China Three Gorges University, Yichang, Hubei (China); Lee, Ming-Hsien; Lin, Tseh-Hsing [Department of Physics, Tamkang University, Taipei, Taiwan (China); Zhang, ZhongFeng; Xie, XiangNan [Department of Physics, University of Science and Technology of China, Hefei, Anhui (China); Zhu, Hong, E-mail: zhuh@ustc.edu.cn [Department of Physics, University of Science and Technology of China, Hefei, Anhui (China)

    2014-07-15

    Highlights: • Rietveld refinement and first-principles calculations are performed for Y{sub 2}MnCrO{sub 6}. • The layered B-site cation ordering is a more reliable structure for Y{sub 2}MnCrO{sub 6}. • Y{sub 2}MnCrO{sub 6} has an insulating ferrimagnetism (0 0 1)-ordered ground state. • The layered ordered pattern plays a key role for the ferrimagnetism in Y{sub 2}MnCrO{sub 6}. - Abstract: We report the Rietveld refinement of powder X-ray diffraction (XRD) pattern and first-principles calculations for the half-Cr{sup 3+} doped YMnO{sub 3} compound. The Rietveld refinement results suggest that the compound has a monoclinic structure with the Mn{sup 3+}/Cr{sup 3+} layers alternately stacking along the [0 0 1] direction. The first-principles calculations show that the structure with layered B-site cation ordering has the lowest total energy; meanwhile, the insulating ferrimagnetic state is more favored compared to the ferromagnetic state, which is in agreement with the reported experimental results. Based upon Goodenough’s model of semi-covalent exchange, we argue that the anisotropic magnetic couplings between the Mn{sup 3+}/Cr{sup 3+} cations ordered in layered pattern play an important role for the ferrimagnetism in the compound.

  4. Different roles of ROS and Nrf2 in Cr(VI)-induced inflammatory responses in normal and Cr(VI)-transformed cells

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Ram Vinod; Pratheeshkumar, Poyil; Son, Yong-Ok; Wang, Lei [Center for Research on Environmental Disease, University of Kentucky, 1095 VA Drive, Lexington, KY 40536 (United States); Department of Toxicology and Cancer Biology, College of Medicine, University of Kentucky, 1095 VA Drive, Lexington, KY 40536 (United States); Hitron, John Andrew [Center for Research on Environmental Disease, University of Kentucky, 1095 VA Drive, Lexington, KY 40536 (United States); Divya, Sasidharan Padmaja; Zhang, Zhuo [Department of Toxicology and Cancer Biology, College of Medicine, University of Kentucky, 1095 VA Drive, Lexington, KY 40536 (United States); Shi, Xianglin, E-mail: xshi5@email.uky.edu [Center for Research on Environmental Disease, University of Kentucky, 1095 VA Drive, Lexington, KY 40536 (United States)

    2016-09-15

    Hexavalent chromium (Cr(VI)) is classified as a human carcinogen. Cr(VI) has been associated with adenocarcinomas and squamous cell carcinoma of the lung. The present study shows that acute Cr(VI) treatment in human bronchial epithelial cells (BEAS-2B) increased inflammatory responses (TNF-α, COX-2, and NF-кB/p65) and expression of Nrf2. Cr(VI)-induced generation of reactive oxygen species (ROS) are responsible for increased inflammation. Despite the fact that Nrf2 is a master regulator of response to oxidative stress, silencing of Nrf2 in the acute Cr(VI) treatment had no effect on Cr(VI)-induced inflammation. In contrast, in Cr(VI)-transformed (CrT) cells, Nrf2 is constitutively activated. Knock-down of this protein resulted in decreased inflammation, while silencing of SOD2 and CAT had no effect in the expression of these inflammatory proteins. Results obtained from the knock-down of Nrf2 in CrT cells are very different from the results obtained in the acute Cr(VI) treatment. In BEAS-2B cells, knock-down of Nrf2 had no effect in the inflammation levels, while in CrT cells a decrease in the expression of inflammation markers was observed. These results indicate that before transformation, ROS plays a critical role while Nrf2 not in Cr(VI)-induced inflammation, whereas after transformation (CrT cells), Nrf2 is constitutively activated and this protein maintains inflammation while ROS not. Constitutively high levels of Nrf2 in CrT binds to the promoter regions of COX-2 and TNF-α, leading to increased inflammation. Collectively, our results demonstrate that before cell transformation ROS are important in Cr(VI)-induced inflammation and after transformation a constitutively high level of Nrf2 is important. - Highlights: • Cr(VI)-induced ROS increased inflammation, while Nrf2 had no effect. • In the CrT cells knock-down of Nrf2 resulted in decreased inflammation. • Mechanistic differences in regulating Cr(VI)-induced inflammation.

  5. Morphology, Structure and Nonstoichiometry of ZnCr2O4 Nanophased Powder

    Directory of Open Access Journals (Sweden)

    O. Milosevic

    2003-10-01

    Full Text Available It is well established that gas/humidity-sensing properties of spinels are markedly influenced by their stoichiometry and microstructure. In this work nucleation and spinel phase development in the Zn-Cr-O system were investigated from the viewpoint of structural and morphological phenomena occurred during nanophased particle synthesis through aerosol reaction. The aerosol was generated from nitrates precursor solution using ultrasonic atomizer operated at 1.7 MHz. The influence of different decomposition schedules on the particle chemical content and morphology was determined by adjusting the processing parameters (aerosol droplet density 3.9x106 droplets/cm3, droplet velocity 0.035m/s, max. temperature 900oC and residence times 3, 6 and 9s. A composite particle structure comprised of primary crystallites sized from 22 to 44nm is revealed by SEM and TEM analysis. XRD structural analysis (crystallite size, microstrains, unit cell and ionic occupancies is performed in accordance with procedure based on Koalariet-Xfit program. A certain degree of non-stochiometry is characteristic for all powders. Homogenous distribution of the constituting elements and Zn/Cr ratio of about 0.68 are proved by EDAX mapping analysis in 470nm sized as-prepared particles. After additional treatment at 1000oC octahedral crystals form with the (111 surface dominat. Evaluated spinel non-stochiometry (Zn/Cr=0.58 is a result of the ZnO dissolving (1.9%wt in the stoichiometric ZnCr2O4. Determination of the way by which the ZnO is incorporated into the spinel lattice is performed according to the procedure based on calculation of both formation and attachment energies.

  6. Electrooxidation of Cr/sup 3+/ at C/PbO/sub 2/

    International Nuclear Information System (INIS)

    Haque, I.U.; Khan, A.; Anwar, S.

    2006-01-01

    Pure and Cu/sup +2/-doped lead dioxide electrodes were prepared by electrodeposition of lead dioxide on carbon-based substrates using lead(II) nitrate bath at 1.5-1.75 V, pH 4-4,5, temperature 60-70 C, and current density 0.0125-0.0175 A/cm/sup 2/. Electrolyses of Cr/sup 3+/ solutions both in divided and undivided cells were used to investigate the electrocatalytic activity. Adhesion and stability of lead dioxide electrodes. Which can serve as industrial electrodes. UV-visible spectrophotometry was used for estimating conversion of Cr/sup 3+/ to Cr/sup 6+/. The electrocatalytic activity of lead dioxide was increased by the doping of copper (II) ions. (author)

  7. Loss in MCL-1 function sensitizes non-Hodgkin's lymphoma cell lines to the BCL-2-selective inhibitor venetoclax (ABT-199)

    International Nuclear Information System (INIS)

    Phillips, D C; Xiao, Y; Lam, L T; Litvinovich, E; Roberts-Rapp, L; Souers, A J; Leverson, J D

    2015-01-01

    As a population, non-Hodgkin's lymphoma (NHL) cell lines positive for the t(14;18) translocation and/or possessing elevated BCL2 copy number (CN; BCL2 High ) are exquisitely sensitive to navitoclax or the B-cell lymphoma protein-2 (BCL-2)-selective inhibitor venetoclax. Despite this, some BCL2 High cell lines remain resistant to either agent. Here we show that the MCL-1-specific inhibitor A-1210477 sensitizes these cell lines to navitoclax. Chemical segregation of this synergy with the BCL-2-selective inhibitor venetoclax or BCL-X L -selective inhibitor A-1155463 indicated that MCL-1 and BCL-2 are the two key anti-apoptotic targets for sensitization. Similarly, the CDK inhibitor flavopiridol downregulated MCL-1 expression and synergized with venetoclax in BCL2 High NHL cell lines to a similar extent as A-1210477. A-1210477 also synergized with navitoclax in the majority of BCL2 Low NHL cell lines. However, chemical segregation with venetoclax or A-1155463 revealed that synergy was driven by BCL-X L inhibition in this population. Collectively these data emphasize that BCL2 status is predictive of venetoclax potency in NHL not only as a single agent, but also in the adjuvant setting with anti-tumorigenic agents that inhibit MCL-1 function. These studies also potentially identify a patient population (BCL2 Low ) that could benefit from BCL-X L (navitoclax)-driven combination therapy

  8. The use of CR1aa for ovine in vitro embryo production

    Directory of Open Access Journals (Sweden)

    Yulnawati

    2006-06-01

    Full Text Available The aim of this study was to investigate the capacity of CR1aa as a simple medium for maturation, fertilization and culture of ovine embryo in vitro. Oocytes were collected by slicing method in Phosphate Buffer Saline (PBS supplemented with 5% Fetal Bovine Serum (FBS and 100 IU/ml penicillin streptomycin. Oocytes were matured in Tissue Culture Medium (TCM-199 as control or CR1aa as treatment medium. Both maturation medium were supplemented with 10% Fetal Bovine Serum (FBS, 10 IU/ml Follicle Stimulating Hormone (FSH, 10 IU/ml Luteinizing Hormone (LH, 1 μg/ml Estradiol and 100 IU/ml penicillin-streptomycin. Oocytes were incubated in 5% CO2 incubator, 38˚C for 24 h. Matured oocytes were fertilized in BO or CR1aa medium, supplemented with 2.5 mM caffeine benzoate and 20 mg /ml heparin. After 18 h in vitro fertilization, oocytes were cultured in TCM-199 or CR1aa medium, both supplemented with 5% FBS, 5 mg/ml insulin and 100 IU/ml penicillin streptomycin. Results showed that the highest maturation rate was found in TCM-199 medium (73.27% and significantly different (P0.05 between cleavage rate of ovine embryos in TCM-199 and CR1aa medium (39.45% vs 50.94%. In conclusion, optimum result on ovine in vitro embryo production can be achieved from a combination of TCM-199 as maturation medium and CR1aa as fertilization and culture medium.

  9. Emissions in potassium vapour under 4S1/2-7S1/2 two-photon nsec excitation

    International Nuclear Information System (INIS)

    Pentaris, D.; Chatzikyriakos, G.; Armyras, A.; Efthimiopoulos, T.

    2010-01-01

    The two-photon excitation of 4S 1/2 -7S 1/2 transition of potassium atoms is studied. Several coherent emissions and processes are possible, such as parametric four-wave (PFWM), parametric six-wave (PSWM) mixing and competition with the stimulated hyper Raman (SHRS) and the amplified spontaneous emission (ASE). The radiations at the transitions 6P 3/2,1/2 -4S 1/2 , 6S 1/2 -4P 3/2,1/2 and 5P 3/2,1/2 -4S 1/2 are emitted only in the forward direction (indicating a parametric process), while the radiation at the transition 4P 3/2,1/2 -4S 1/2 is emitted in the forward and in the backward direction, indicating an ASE process.

  10. Microstructural origins of high strength and high ductility in an AlCoCrFeNi2.1 eutectic high-entropy alloy

    International Nuclear Information System (INIS)

    Gao, Xuzhou; Lu, Yiping; Zhang, Bo; Liang, Ningning; Wu, Guanzhong; Sha, Gang; Liu, Jizi; Zhao, Yonghao

    2017-01-01

    Recent studies indicate that eutectic high-entropy alloys can simultaneously possess high strength and high ductility, which have potential applications in industrial fields. Nevertheless, microstructural origins of the excellent strength–ductility combination remain unclear. In this study, an AlCoCrFeNi 2.1 eutectic high-entropy alloy was prepared with face-centered cubic (FCC)(L1 2 )/body-centered-cubic (BCC)(B2) modulated lamellar structures and a remarkable combination of ultimate tensile strength (1351 MPa) and ductility (15.4%) using the classical casting technique. Post-deformation transmission electron microscopy revealed that the FCC(L1 2 ) phase was deformed in a matter of planar dislocation slip, with a slip system of {111} <110>, and stacking faults due to low stacking fault energy. Due to extreme solute drag, high densities of dislocations are distributed homogeneously at {111} slip plane. In the BCC(B2) phase, some dislocations exist on two {110} slip bands. The atom probe tomography analysis revealed a high density of Cr-enriched nano-precipitates, which strengthened the BCC(B2) phase by Orowan mechanisms. Fracture surface observation revealed a ductile fracture in the FCC(L1 2 ) phase and a brittle-like fracture in the BCC(B2) lamella. The underlying mechanism for the high strength and high ductility of AlCoCrFeNi 2.1 eutectic high-entropy alloy was finally analyzed based on the coupling between the ductile FCC(L1 2 ) and brittle BCC(B2) phases.

  11. Terapia com inibidor da ECA com dosagens relativamente altas e risco de agravamento renal na insuficiência cardíaca crônica ACE-inhibitor therapy at relatively high doses and risk of renal worsening in chronic heart failure

    Directory of Open Access Journals (Sweden)

    Renato De Vecchis

    2011-12-01

    : ACE-inhibitors "high" dose, age, basal LVEF, history of repeated intensive intravenous loop diuretic therapies (IV diur, diabetes, basal Cr, history of hypertension, systolic blood pressure < 100 mm Hg. RESULTS: 57 patients were recruited, of whom 15 were treated with ACE-inhibitor "high" dose. During a mean follow-up of 718 days, ARD occurred in 17 (29.8% patients. Only ACE-inhibitor "high" dose (HR: 12.4681 C.I.: 2.1614-71.9239 p=0.0050 and basal Cr (HR: 1.2344 C.I.: 1.0414-1.4632 p=0.0157 were shown to predict ARD. Moreover, ACE-inhibitor "high" doses were shown to fail to predict ARD in both CHF without IV diur and CHF with diabetes. CONCLUSION: In III NYHA class CHF, ACE-inhibitor "high" doses and a higher basal Cr predicted ARD. Nephrotoxicity related to ACE-inhibitor "high" doses was increased by IV diur, whereas it was not detected in CHF patients with diabetes.

  12. An electrochemical study of U(VI) and Cr(VI) in molten borates

    International Nuclear Information System (INIS)

    Brigaudeau, M.; Gregori de Pinochet, I. de

    1977-01-01

    The electrochemical reduction of U(VI) and Cr(VI), in molten Na 2 B 4 O 7 at 800 deg C was studied by means of linear sweep voltammetry, and chronopotentiometry. The reduction of U(VI) to U(V) proceeded reversibly at a platinum electrode. The diffusion coefficient for the U(VI) species at 800 deg C was 4.10 -7 cm 2 .s -1 . The activation energy of diffusion was (34,8 +- 0,8) kcal. mole -1 . Electrochemical studies of Cr(VI) at 800 0 C reveal a two-step reduction process at a platinum electrode. Only the voltammogram for the first step charge transfer process was studied. Analysis indicated that Cr(VI) is reversibly reduced to Cr(III) at a platinum electrode. The diffusion coefficient for Cr(VI) at 800 0 C is 1,9.10 -7 cm 2 .s -1 [fr

  13. Cr6+-containing phases in the system CaO-Al2O3-CrO42--H2O at 23 °C

    Science.gov (United States)

    Pöllmann, Herbert; Auer, Stephan

    2012-01-01

    Synthesis and investigation of lamellar calcium aluminium hydroxy salts was performed to study the incorporation of chromate ions in the interlayer of lamellar calcium aluminium hydroxy salts. Different AFm-phases (calcium aluminate hydrate with alumina, ferric oxide, mono-anion phase) containing chromate were synthesized. These AFm-phases belong to the group of layered double hydroxides (LDHs). 3CaO·Al2O3·CaCrO4·nH2O and C3A·1/2Ca(OH)2·1/2CaCrO4·12H2O were obtained as pure phases and their different distinct interlayer water contents and properties determined. Solid solution of chromate-containing phases and tetracalcium-aluminate-hydrate (TCAH) were studied. The uptake of chromate into TCAH from solutions was proven. Chromate contents in solution decrease to <0.2 mg/l.

  14. Non-linear dose-response of aluminium hydroxide adjuvant particles: Selective low dose neurotoxicity

    International Nuclear Information System (INIS)

    Crépeaux, Guillemette; Eidi, Housam; David, Marie-Odile; Baba-Amer, Yasmine; Tzavara, Eleni; Giros, Bruno; Authier, François-Jérôme; Exley, Christopher; Shaw, Christopher A.; Cadusseau, Josette

    2017-01-01

    Aluminium (Al) oxyhydroxide (Alhydrogel ® ), the main adjuvant licensed for human and animal vaccines, consists of primary nanoparticles that spontaneously agglomerate. Concerns about its safety emerged following recognition of its unexpectedly long-lasting biopersistence within immune cells in some individuals, and reports of chronic fatigue syndrome, cognitive dysfunction, myalgia, dysautonomia and autoimmune/inflammatory features temporally linked to multiple Al-containing vaccine administrations. Mouse experiments have documented its capture and slow transportation by monocyte-lineage cells from the injected muscle to lymphoid organs and eventually the brain. The present study aimed at evaluating mouse brain function and Al concentration 180 days after injection of various doses of Alhydrogel ® (200, 400 and 800 μg Al/kg of body weight) in the tibialis anterior muscle in adult female CD1 mice. Cognitive and motor performances were assessed by 8 validated tests, microglial activation by Iba-1 immunohistochemistry, and Al level by graphite furnace atomic absorption spectroscopy. An unusual neuro-toxicological pattern limited to a low dose of Alhydrogel ® was observed. Neurobehavioural changes, including decreased activity levels and altered anxiety-like behaviour, were observed compared to controls in animals exposed to 200 μg Al/kg but not at 400 and 800 μg Al/kg. Consistently, microglial number appeared increased in the ventral forebrain of the 200 μg Al/kg group. Cerebral Al levels were selectively increased in animals exposed to the lowest dose, while muscle granulomas had almost Completely disappeared at 6 months in these animals. We conclude that Alhydrogel ® injected at low dose in mouse muscle may selectively induce long-term Al cerebral accumulation and neurotoxic effects. To explain this unexpected result, an avenue that could be explored in the future relates to the adjuvant size since the injected suspensions corresponding to the lowest dose

  15. Ocular Hypotensive Response in Nonhuman Primates of (8R)-1-[(2S)-2-Aminopropyl]-8,9-dihydro-7H-pyrano[2,3-g]indazol-8-ol a Selective 5-HT2 Receptor Agonist.

    Science.gov (United States)

    May, Jesse A; Sharif, Najam A; McLaughlin, Marsha A; Chen, Hwang-Hsing; Severns, Bryon S; Kelly, Curtis R; Holt, William F; Young, Richard; Glennon, Richard A; Hellberg, Mark R; Dean, Thomas R

    2015-11-25

    Recently, it has been reported that 5-HT2 receptor agonists effectively reduce intraocular pressure (IOP) in a nonhuman primate model of glaucoma. Although 1-[(2S)-2-aminopropyl]indazol-6-ol (AL-34662) was shown to have good efficacy in this nonhuman primate model of ocular hypertension as well as a desirable physicochemical and permeability profile, subsequently identified cardiovascular side effects in multiple species precluded further clinical evaluation of this compound. Herein, we report selected structural modifications that resulted in the identification of (8R)-1-[(2S)-2-aminopropyl]-8,9-dihydro-7H-pyrano[2,3-g]indazol-8-ol (13), which displayed an acceptable profile to support advancement for further preclinical evaluation as a candidate for proof-of-concept studies in humans.

  16. Modelling Cr depletion under a growing Cr2O3 layer on austenitic stainless steel: the influence of grain boundary diffusion

    DEFF Research Database (Denmark)

    Hansson, Anette Nørgaard; Hattel, Jesper Henri; Dahl, Kristian Vinter

    2009-01-01

    according to a parabolic rate law as a consequence of rate limiting diffusion of Cr cations through the oxide layer; the retraction of the oxide/alloy interface associated with the removal of Cr atoms from the substrate is included in the calculations. Numerically, the movement of the oxide/alloy interface......The oxidation behaviour of austenitic stainless steels in the temperature range 723–1173K is strongly influenced by the grain size of the oxidizing alloy. In this work the evolution of the concentration profiles of Cr, Ni and Fe in the substrate below a growing Cr2O3 layer is simulated...... with a Fisher-type numerical model, which takes both volume and grain boundary diffusion into consideration. The model is based on a two-dimensional control volume-based solution of Fick’s 2nd law for multicomponent diffusion and includes crossterm diffusion coefficients. The oxide layer is assumed to grow...

  17. Thermodynamic modeling of La2O3-SrO-Mn2O3-Cr2O3 for solid oxide fuel cell applications

    DEFF Research Database (Denmark)

    Povoden-Karadeniz, E.; Chen, Ming; Ivas, Toni

    2012-01-01

    The thermodynamic La–Sr–Mn–Cr–O oxide database is obtained as an extension of thermodynamic descriptions of oxide subsystems using the calculation of phase diagrams approach. Concepts of the thermodynamic modeling of solid oxide phases are discussed. Gibbs energy functions of SrCrO4, Sr2.67Cr2O8......, Sr2CrO4, and SrCr2O4 are presented, and thermodynamic model parameters of La–Sr–Mn–Chromite perovskite are given. Experimental solid solubilities and nonstoichiometries in La1xSrxCrO3d and LaMn1xCrxO3d are reproduced by the model. The presented oxide database can be used for applied computational...... thermodynamics of traditional lanthanum manganite cathode with Cr-impurities. It represents the fundament for extensions to higher orders, aiming on thermodynamic calculations in noble symmetric solid oxide fuel cells...

  18. Thermochemistry of α-D-xylose(cr)

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Ribeiro da Silva, Maria D.M.C.; Lobo Ferreira, Ana I.M.C.; Shi, Quan; Woodfield, Brian F.; Goldberg, Robert N.

    2013-01-01

    Highlights: ► Well-characterized material. ► Oxygen bomb calorimetry. ► Heat capacities obtained by using a Physical Property Measurement System. ► Thermochemical Network Calculations. ► Accurate thermodynamic property values of a key biochemical substance. -- Abstract: The thermochemistry of α-D-xylose(cr) was studied by means of oxygen bomb calorimetry and a Physical Property Measurement System (PPMS) in zero magnetic field. The sample of α-D-xylose(cr) used in this study was one well-characterized by HPLC, Karl Fischer analysis, NMR, and by carbon dioxide analysis. The standard molar enthalpy of combustion was found to be Δ c H m o = −(2342.2 ± 0.8) kJ·mol −1 at T = 298.15 K and at the standard pressure p° = 0.1 MPa. The standard molar heat capacity for α-D-xylose(cr) was measured with the PPMS over the temperature range 1.9001 ⩽ T/K ⩽ 303.66. At T = 298.15 K, C p,m o = (178.1 ± 1.8) J·K −1 ·mol −1 . The values of C p,m o were fit as a function of T by using theoretical and empirical models for appropriate temperature ranges. The results of these fits were used to calculate values of C p,m o , the entropy increment Δ 0 T S m o , Δ 0 T H m o , and Φ m o =(Δ 0 T S m o -Δ 0 T H m o /T) from T = 0.5 K to T = 300 K. Derived quantities for α-D-xylose(cr) are the standard molar enthalpy of formation Δ f H m o = −(1054.5 ± 1.1) kJ·mol −1 , the third law standard molar entropy S m o = (175.3 ± 1.9) J·K −1 ·mol −1 , and the standard molar Gibbs energy of formation Δ f G m o = −(750.5 ± 1.0) kJ·mol −1 . A comparison of values of Δ c H m o and S m o for the five-carbon aldoses demonstrated a striking similarity in the values of these respective properties for α-D-xylose(cr), D-ribose(cr), and D-arabinose(cr). Thermochemical network calculations were performed that led to values of the standard formation properties at T = 298.15 K for a variety of biochemical substances: D-xylose(aq), D-xylose − (aq), D-xylose 2

  19. Effect of processing time delay on the dose response of Kodak EDR2 film.

    Science.gov (United States)

    Childress, Nathan L; Rosen, Isaac I

    2004-08-01

    Kodak EDR2 film is a widely used two-dimensional dosimeter for intensity modulated radiotherapy (IMRT) measurements. Our clinical use of EDR2 film for IMRT verifications revealed variations and uncertainties in dose response that were larger than expected, given that we perform film calibrations for every experimental measurement. We found that the length of time between film exposure and processing can affect the absolute dose response of EDR2 film by as much as 4%-6%. EDR2 films were exposed to 300 cGy using 6 and 18 MV 10 x 10 cm2 fields and then processed after time delays ranging from 2 min to 24 h. An ion chamber measured the relative dose for these film exposures. The ratio of optical density (OD) to dose stabilized after 3 h. Compared to its stable value, the film response was 4%-6% lower at 2 min and 1% lower at 1 h. The results of the 4 min and 1 h processing time delays were verified with a total of four different EDR2 film batches. The OD/dose response for XV2 films was consistent for time periods of 4 min and 1 h between exposure and processing. To investigate possible interactions of the processing time delay effect with dose, single EDR2 films were irradiated to eight different dose levels between 45 and 330 cGy using smaller 3 x 3 cm2 areas. These films were processed after time delays of 1, 3, and 6 h, using 6 and 18 MV photon qualities. The results at all dose levels were consistent, indicating that there is no change in the processing time delay effect for different doses. The difference in the time delay effect between the 6 and 18 MV measurements was negligible for all experiments. To rule out bias in selecting film regions for OD measurement, we compared the use of a specialized algorithm that systematically determines regions of interest inside the 10 x 10 cm2 exposure areas to manually selected regions of interest. There was a maximum difference of only 0.07% between the manually and automatically selected regions, indicating that the use of

  20. Analysis of CR1 Repeats in the Zebra Finch Genome

    Directory of Open Access Journals (Sweden)

    George E. Liu

    2013-06-01

    Full Text Available Most bird species have smaller genomes and fewer repeats than mammals. Chicken Repeat 1 (CR1 repeat is one of the most abundant families of repeats, ranging from ~133,000 to ~187,000 copies accounting for ~50 to ~80% of the interspersed repeats in the zebra finch and chicken genomes, respectively. CR1 repeats are believed to have arisen from the retrotransposition of a small number of master elements, which gave rise to multiple CR1 subfamilies in the chicken. In this study, we performed a global assessment of the divergence distributions, phylogenies, and consensus sequences of CR1 repeats in the zebra finch genome. We identified and validated 34 CR1 subfamilies and further analyzed the correlation between these subfamilies. We also discovered 4 novel lineage-specific CR1 subfamilies in the zebra finch when compared to the chicken genome. We built various evolutionary trees of these subfamilies and concluded that CR1 repeats may play an important role in reshaping the structure of bird genomes.