  1. Method’s and Test Stand for Electronic PID Controller

    Directory of Open Access Journals (Sweden)

    Cristian Paul Chioncel

    2009-01-01

    Full Text Available The paper presents method’s and a testing stand for electronic controller using for this a signal generator and a digital oscilloscope respectively the virtual instrumentation and the signal acquisitions from the controllers input and output through an data acquisition board and an PC on that Lab View program runs.

  2. PELE-IC test problems

    International Nuclear Information System (INIS)

    Gong, E.Y.; Alexander, E.E.; McMaster, W.H.; Quinones, D.F.

    1979-01-01

    This report provides prospective users of the Lawrence Livermore Laboratory (LLL) fluid-structure interaction computer code, PELE-IC, a variety of test problems for verifying the code on CDC 7600 computer systems at facilities external to the LLL environment. The test problems have been successfully run on CDC 7600 computers at the LLL and Lawrence Berkeley Laboratory (LBL) computer centers

  3. Generic test platform for representative tests of safety I/C systems - 15546

    International Nuclear Information System (INIS)

    Fourestie, B.; Kuck, H.; Richter, J.; Rieche, S.; Waitz, M.

    2015-01-01

    In compliance with the IEC 61513 safety Instrumentation and Control (I/C) systems must be successfully validated in their final configuration prior to installation on site and commissioning. However the contingent need for modifications during system validation activities or subsequently during the commissioning phase may entail long and costly re-engineering of the I/C systems. With the view to ease these possible modifications, a Generic Test Platform has been developed by AREVA which allows combining a real I/C system subpart with an emulation server. This platform provides a faithful representation of the I/C System allowing crediting the validation test results carried out on this platform. (authors)

  4. Multi-Purpose Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Multi-Purpose Test Stand is used for a wide variety of tests. The Stand is designed to be rotated through a range of fixed yaw positions to allow engines to be...

  5. The Stimulus test stand

    International Nuclear Information System (INIS)

    Christofek, L.; Rapidis, P.; Reinhard, A.; Fermilab

    2005-01-01

    The Stimulus Test Stand was originally constructed and assembled for testing the SVX2 ASIC readout and then upgraded for SVX3 ASIC prototyping and testing. We have modified this system for SVX4 ASIC [1] prototype testing. We described the individual components below. Additional details for other hardware for SVX4 testing can be found in reference [2]. We provide a description of the Stimulus Test Stand used for prototype testing of the SVX4 chip

  6. Industry-Oriented Laboratory Development for Mixed-Signal IC Test Education

    Science.gov (United States)

    Hu, J.; Haffner, M.; Yoder, S.; Scott, M.; Reehal, G.; Ismail, M.

    2010-01-01

    The semiconductor industry is lacking qualified integrated circuit (IC) test engineers to serve in the field of mixed-signal electronics. The absence of mixed-signal IC test education at the collegiate level is cited as one of the main sources for this problem. In response to this situation, the Department of Electrical and Computer Engineering at…

  7. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  8. Prediction of fracture toughness K/sub Ic/ of steel from Charpy impact test results

    Energy Technology Data Exchange (ETDEWEB)

    Iwadate, Tadao; Tanaka, Yasuhiko; Takemata, Hiroyuki; Terashima, Shuhei

    1986-08-01

    This paper presents a method to predict the fracture toughness K/sub Ic/ and/or K/sub Id/ of steels using their Charpy impact test results and tensile properties. The fracture toughness, Charpy impact and tensile properties of 2 1/4 Cr-1Mo, ASTM A508 Cl.1, A508 Cl.2 A508 Cl.3 and A533 Gr.B Cl.1 steels were measured and analysed on the basis of the excess temperature (test temperature minus FATT) and Rolfe-Novak correlation. The relationship between K/sub Ic//K/sub Ic-us/ and the excess temperature, where K/sub Ic-us/ is the upper-shelf fracture toughness K/sub Ic/ predicted by Rolfe-Novak correlation, discloses that the K/sub Ic/ transition curves of several steels are representable by only one trend curve of K/sub Ic//K/sub Ic-us/ or K/sub Id//K/sub Id-us/ versus excess temperature relation. This curve is denoted as a ''master curve''. By using this curve, the fracture toughness of steel can be predicted using Charpy impact and tensile test results. By taking account of the scattering of both the fracture toughness and Charpy impact test results, the confidence limits of the master curve were also determined. Another approach to develop more general procedure of predicting the fracture toughness K/sub Ic/ is also discussed.

  9. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  10. Shallow foundation model tests in Europe

    Czech Academy of Sciences Publication Activity Database

    Feda, Jaroslav; Simonini, P.; Arslan, U.; Georgiodis, M.; Laue, J.; Pinto, I.

    1999-01-01

    Roč. 2, č. 4 (1999), s. 447-475 ISSN 1436-6517. [Int. Conf. on Soil - Structure Interaction in Urban Civ. Engineering. Darmstadt, 08.10.1999-09.10.1999] R&D Projects: GA MŠk OC C7.10 Keywords : shallow foundations * model tests * sandy subsoil * bearing capacity * settlement Subject RIV: JM - Building Engineering

  11. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  12. Variable Attitude Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Variable Attitude Test Stand designed and built for testing of the V-22 tilt rotor aircraft propulsion system, is used to evaluate the effect of aircraft flight...

  13. Stand for testing the electrical race car engine

    Science.gov (United States)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  14. A cryogenic test stand for full length SSC magnets with superfluid capability

    International Nuclear Information System (INIS)

    Peterson, T.J.; Mazur, P.O.

    1989-02-01

    The Fermilab Magnet Test Facility performs testing of the full scale SSC magnets on test stands capable of simulating the cryogenic environment of the SSC main ring. One of these test stands, Stand 5, also has the ability to operate the magnet under test at temperatures from 1.8K to 4.5K with either supercritical helium or subcooled liquid, providing at least 25 Watts of refrigeration. At least 50 g/s flow is available from 2.3K to 4.5K, whereas superfluid operation occurs with zero flow. Cooldown time from 4.5K to 1.8K is 1.5 hours. A maximum current capability of 10,000 amps is provided, as is instrumentation to monitor and control the cryogenic conditions. This paper describes the cryogenic design of this test stand. 8 refs., 6 figs

  15. Performance of 3.9 GHz SRF cavities at Fermilab's ILCTA_MDB nhorizontal test stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; Hocker, Andy; /Fermilab

    2008-08-01

    Fermilab is building a cryomodule containing four 3.9 GHz superconducting radio frequency (SRF) cavities for the Free electron LASer in Hamburg (FLASH) facility at the Deutsches Elektronen-SYnchrotron (DESY) laboratory. Before assembling the cavities into the cryomodule, each individual cavity is tested at Fermilab's Horizontal Test Stand (HTS). The HTS provides the capability to test fully-dressed SRF cavities at 1.8 K with high-power pulsed RF in order to verify that the cavities achieve performance requirements under these conditions. The performance at the HTS of the 3.9 GHz cavities built for FLASH is presented here.

  16. High-voltage test stand at Livermore

    International Nuclear Information System (INIS)

    Smith, M.E.

    1977-01-01

    This paper describes the present design and future capability of the high-voltage test stand for neutral-beam sources at Lawrence Livermore Laboratory. The stand's immediate use will be for testing the full-scale sources (120 kV, 65 A) for the Tokamak Fusion Test Reactor. It will then be used to test parts of the sustaining source system (80 kV, 85 A) being designed for the Magnetic Fusion Test Facility. Following that will be an intensive effort to develop beams of up to 200 kV at 20 A by accelerating negative ions. The design of the test stand features a 5-MVA power supply feeding a vacuum tetrode that is used as a switch and regulator. The 500-kW arc supply and the 100-kW filament supply for the neutral-beam source are battery powered, thus eliminating one or two costly isolation transformers

  17. TESTING OF THE TRUTH IN ANDREI PLATONOV’S TALE THE FOUNDATION PIT

    Directory of Open Access Journals (Sweden)

    Marina Vladimirovna Zavarkina

    2014-11-01

    Full Text Available Analyzing the manuscript of Andrei Platonov’s tale The Foundation Pit and his early journalism the author traces the evolution of Platonov’s views on the problem of the search for the truth. Analysis of the dynamic transcription of the The Foundation Pit manuscript enabled to show that by the end of the 1920s Platonov had abandoned rationalistic interpretations of the concept of «truth», including in its "Bogdanov’s edition". Platonov increasingly questioned the capabilities of socialist science, based on materialism, to fi nd out the truth about the world, and changed his views on work as the only method of learning the truth. He departed from the materialistic concept of learning and shifted towards the religious and philosophical tradition: in the end the formula of P. Florensky "truth-estina (to be in existence" is getting more and more essential and it is outlined a shift of the concept of “truth” from a cognitive-materialistic category (“invent” / “to do” truth to an ontological and moral category.

  18. Men and IC

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  19. General IC Symptoms

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  20. F-1 Engine for Saturn V Undergoing a Static Test

    Science.gov (United States)

    1964-01-01

    The flame and exhaust from the test firing of an F-1 engine blast out from the Saturn S-IB Static Test Stand in the east test area of the Marshall Space Flight Center. A Cluster of five F-1 engines, located in the S-IC (first) stage of the Saturn V vehicle, provided over 7,500,000 pounds of thrust to launch the giant rocket. The towering 363-foot Saturn V was a multistage, multiengine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  1. Assembly and installation of the large coil test facility test stand

    International Nuclear Information System (INIS)

    Queen, C.C. Jr.

    1983-01-01

    The Large Coil Test Facility (LCTF) was built to test six tokamak-type superconducting coils, with three to be designed and built by US industrial teams and three provided by Japan, Switzerland, and Euratom under an international agreement. The facility is designed to test these coils in an environment which simulates that of a tokamak. The heart of this facility is the test stand, which is made up of four major assemblies: the Gravity Base Assembly, the Bucking Post Assembly, the Torque Ring Assembly, and the Pulse Coil Assembly. This paper provides a detailed review of the assembly and installation of the test stand components and the handling and installation of the first coil into the test stand

  2. SSRL photocathode RF gun test stand

    International Nuclear Information System (INIS)

    Hernandez, M.; Baltay, M.; Boyce, A.

    1995-01-01

    A photocathode RF gun test stand designed for the production and study of high brightness electron beams will be constructed at SSRL. The beam will be generated from a laser driven third generation photocathode RF gun being developed in collaboration with BNL, LBL, and UCLA. The 3-5 [MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section, in order to achieve the desired low emittance beam, emittance compensation with solenoidal focusing will be employed

  3. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Science.gov (United States)

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  4. THE 30-S CHAIR STAND TEST AND HABITUAL MOBILITY PREDICT REHABILITATION NEEDS AFTER ACUTE ADMISSION

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Nørgaard, Birgitte; Backer Mogensen, Christian

    2016-01-01

    that no approval is needed. Purpose The study aimed to evaluate if the 30 Second Chair Stand test (30s-CST) combined with other variables was able to predict rehabilitation needs among acutely admitted elderly patient. Low physical ability were defined as a 30s-CST–score ≤ 8 one month after admission......Relevance: Responding to Changing Population Needs. The elderly population is growing and represents an increasing proportion of elderly admitted to a short stay unit in an emergency department (ED). One month after admission a fifth of the elderly patients have low physical ability and therefore...... were included if oriented in time and place, able to sit on a chair and have a 30s-CST–score ≤ 8. Baseline data were collected within the first 48 hours of admission and the 30s-CST again one month after admission. All risk factors are identified in the literature. The 30s-CST is used at community...

  5. A Cryogenic Test Stand for Large Superconducting Solenoid Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Rabehl, R. [Fermilab; Carcagno, R. [Fermilab; Nogiec, J. [Fermilab; Orris, D. [Fermilab; Soyars, W. [Fermilab; Sylvester, C. [Fermilab

    2013-01-01

    A new test stand for testing large superconducting solenoid magnets at the Fermilab Central Helium Liquifier (CHL) has been designed, and operated. This test stand has been used to test a coupling coil for the Muon Ionization Cooling Experiment (MICE), and future uses include solenoids for the Fermilab mu2e experiment. This paper describes the test stand design and operation including controlled cool-down and warm-up. Overviews of the process controls system and the quench management system are also included.

  6. Performance review of an indigenously developed high power test stand built for the Indian S-band 5 MW pulsed klystron development

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Baxy, D.; Mulchandani, J.; Hannurkar, P.R.; Joshi, L.M.

    2003-01-01

    CAT took up development of 5 MW S-Band klystrons indigenously in collaboration with CEERI Pilani. The development of klystron prototype is completed. These klystrons are very crucial devices, for energizing the 10-20 MeV electron accelerators, which are developed in the country for various industrial, medical and scientific applications. A test station has been developed indigenously at CAT for these klystrons. It consists of a 12 MW peak power 130 kV klystron pulse modulator, a 1 : 10 pulse transformer, 130 kV high voltage deck having high voltage pulse divider, pulse current transformer as well indigenously built klystron socket, filament supplies, klystron support structure and pulse transformer oil tank. After development/rigorous testing the test stand was shifted to CEERI and was installed and commissioned there by CAT. Gun collector test module and prototypes of the 5 MW klystron were tested, aged and conditioned at high power using this test stand. The details of the system / test results are discussed

  7. IC Treatment: Surgical Procedures

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  8. IC: Frequently Asked Questions

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  9. Isopropyl alcohol tank installed at A-3 Test Stand

    Science.gov (United States)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  10. Separation of traveling and standing waves in a finite dispersive string with partial or continuous viscoelastic foundation

    Science.gov (United States)

    Cheng, Xiangle; Blanchard, Antoine; Tan, Chin An; Lu, Huancai; Bergman, Lawrence A.; McFarland, D. Michael; Vakakis, Alexander F.

    2017-12-01

    The free and forced vibrations of a linear string with a local spring-damper on a partial elastic foundation, as well as a linear string on a viscoelastic foundation conceptualized as a continuous distribution of springs and dampers, are studied in this paper. Exact, analytical results are obtained for the free and forced response to a harmonic excitation applied at one end of the string. Relations between mode complexity and energy confinement with the dispersion in the string system are examined for the steady-state forced vibration, and numerical methods are applied to simulate the transient evolution of energy propagation. Eigenvalue loci veering and normal mode localization are observed for weakly coupled subsystems, when the foundation stiffness is sufficiently large, for both the spatially symmetric and asymmetric systems. The forced vibration results show that nonproportional damping-induced mode complexity, for which there are co-existing regions of purely traveling waves and standing waves, is attainable for the dispersive string system. However, this wave transition phenomenon depends strongly on the location of the attached discrete spring-damper relative to the foundation and whether the excitation frequency Ω is above or below the cutoff frequency ωc. When Ωcontrol strategies.

  11. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  12. Reliability and sensitivity to change of the timed standing balance test in children with down syndrome

    Directory of Open Access Journals (Sweden)

    Vencita Priyanka Aranha

    2016-01-01

    Full Text Available Objective: To estimate the reliability and sensitivity to change of the timed standing balance test in children with Down syndrome (DS. Methods: It was a nonblinded, comparison study with a convenience sample of subjects consisting of children with DS (n = 9 aged 8–17 years. The main outcome measure was standing balance which was assessed using timed standing balance test, the time required to maintain in four conditions, eyes open static, eyes closed static, eyes open dynamic, and eyes closed dynamic. Results: Relative reliability was excellent for all four conditions with an Interclass Correlation Coefficient (ICC ranging from 0.91 to 0.93. The variation between repeated measurements for each condition was minimal with standard error of measurement (SEM of 0.21–0.59 s, suggestive of excellent absolute reliability. The sensitivity to change as measured by smallest real change (SRC was 1.27 s for eyes open static, 1.63 s for eyes closed static, 0.58 s for eyes open dynamic, and 0.61 s for eyes closed static. Conclusions: Timed standing balance test is an easy to administer test and sensitive to change with strong absolute and relative reliabilities, an important first step in establishing its utility as a clinical balance measure in children with DS.

  13. CENTRIFUGAL VIBRATION TEST OF RC PILE FOUNDATION

    Science.gov (United States)

    Higuchi, Shunichi; Tsutsumiuchi, Takahiro; Otsuka, Rinna; Ito, Koji; Ejiri, Joji

    It is necessary that nonlinear responses of structures are clarified by soil-structure interaction analysis for the purpose of evaluating the seismic performances of underground structure or foundation structure. In this research, centrifuge shake table tests of reinforced concrete pile foundation installed in the liquefied ground were conducted. Then, finite element analyses for the tests were conducted to confirm an applicability of the analytical method by comparing the experimental results and analytical results.

  14. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    Directory of Open Access Journals (Sweden)

    Paula F. S. Silva

    2014-04-01

    Full Text Available BACKGROUND: Subjects with neurological disease (ND usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. OBJECTIVE: To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. METHOD: A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. RESULTS: Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99 for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99 for stroke and inter-rater reliability (ICC=0.99 for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77, and the feasibility and safety were good for subjects with Alzheimer's disease. CONCLUSIONS: The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement

  15. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    Science.gov (United States)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  16. Problem solving in foundation engineering using foundationPro

    CERN Document Server

    Yamin, Mohammad

    2016-01-01

    This book is at once a supplement to traditional foundation engineering textbooks and an independent problem-solving learning tool. The book is written primarily for university students majoring in civil or construction engineering taking foundation analysis and design courses to encourage them to solve design problems. Its main aim is to stimulate problem solving capability and foster self-directed learning. It also explains the use of the foundationPro software, available at no cost, and includes a set of foundation engineering applications. Taking a unique approach, Dr. Yamin summarizes the general step-by-step procedure to solve various foundation engineering problems, illustrates traditional applications of these steps with longhand solutions, and presents the foundationPro solutions. The special structure of the book allows it to be used in undergraduate and graduate foundation design and analysis courses in civil and construction engineering. The book stands as valuable resource for students, faculty, ...

  17. A high voltage test stand for electron gun qualification for LINACs

    International Nuclear Information System (INIS)

    Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2011-01-01

    An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

  18. Test Stand for Linear Induction Accelerator Optimization

    International Nuclear Information System (INIS)

    Ong, M; DeHope, B; Griffin, K; Goerz, D; Kihara, R; Vogtlin, G; Zentler, J M; Scarpetti, R

    2003-01-01

    Lawrence Livermore National Laboratory has designed and constructed a test stand to improve the voltage regulation in our Flash X-Ray (FXR) accelerator cell. The goal is to create a more mono-energetic electron beam that will create an x-ray source with a smaller spot size. Studying the interaction of the beam and pulse-power system with the accelerator cell will improve the design of high-current accelerators at Livermore and elsewhere. On the test stand, a standard FXR cell is driven by a flexible pulse-power system and the beam current is simulated with a switched center conductor. The test stand is fully instrumented with high-speed digitizers to document the effect of impedance mismatches when the cell is operated under various full-voltage conditions. A time-domain reflectometry technique was also developed to characterize the beam and cell interactions by measuring the impedance of the accelerator and pulse-power component. Computer models are being developed in parallel with the testing program to validate the measurements and evaluate different design changes. Both 3D transient electromagnetic and circuit models are being used

  19. Constitutional Law--State Action--Charitable Foundations--Racial Discrimination--Tax Exemption May be State Action under Civil Rights Act.--Jackson v. Statler Foundation, 496 F.2d 623 (2nd Cir. 1974), cert. denied, 43 U.S.L.W. 3452 (U.S. Feb. 14, 1975)

    Science.gov (United States)

    Wolf, Sara Straight

    1975-01-01

    The author argues that if the positive values which private foundations can provide are to continue, the finding of state action in the granting of tax exemptions to private foundations cannot be permitted to stand. Other existing methods for disallowing tax exemptions for foundations dedicated to invidiously discriminatory practices are…

  20. A Cryogenic Test Stand for LHC Quadrupole Magnets

    International Nuclear Information System (INIS)

    Carcagno, R.H.; Huang, Y.; Orris, D.F.; Peterson, T.J.; Rabehl, R.J.

    2004-01-01

    A new test stand for testing LHC interaction region (IR) quadrupole magnets at the Fermilab Magnet Test Facility has been designed and operated. The test stand uses a double bath system with a lambda plate to provide the magnet with a stagnant bath of pressurized He II at 1.9 K and 0.13 MPa. A cryostated magnet 0.91 m in diameter and up to 13 m in length can be accommodated. This paper describes the system design and operation. Issues related to both 4.5 K and 1.9 K operations and magnet quenching are highlighted. An overview of the data acquisition and cryogenics controls systems is also included

  1. Software Testing An ISTQB-ISEB Foundation Guide

    CERN Document Server

    Hambling, Brian; Morgan, Peter; Samaroo, Angelina; Thompson, Geoff; Williams, Peter

    2010-01-01

    This practical guide provides insight into software testing, explaining the basics of the testing process and how to perform effective tests. It provides an overview of different techniques and how to apply them. It is the bestselling official textbook of the ISTQB - ISEB Foundation Certificate in Software Testing, updated to the 2010 syllabus.

  2. HISTRAP [Heavy Ion Storage Ring for Atomic Physics] vacuum test stand for pressures of 10-12 Torr

    International Nuclear Information System (INIS)

    Johnson, J.W.; Atkins, W.H.; Dowling, D.T.; McConnell, J.W.; Milner, W.T.; Olsen, D.K.

    1988-01-01

    HISTRAP, Heavy Ion Storage Ring for Atomic Physics, is a proposed synchrotron/cooler/storage ring accelerator optimized for advanced atomic physics research. The ring has a circumference of 46.8 m, a bore diameter of about 15 cm, and requires a vacuum of 10 -12 Torr in order to decelerate highly-charged very-heavy ions down to low energies. To be able to test components and procedures to achieve this pressure, a test stand approximately modeling one-sixteenth of the ring vacuum chamber has been built. The 3.5-m-long test stand has been fabricated from 10-cm-diameter components, with 316LN stainless steel flanges. Prior to assembly, these components were vacuum fired at 950/degree/C at a pressure of 10 -4 Torr. The test stand is bakeable in situ at 300/degree/C. Pumping is achieved with two 750-L/s titanium sublimator pumps and one 60-L/s ion pump. Pressure is measured with two extractor ion gauges and a 10 -14 PP RGA. The roughing for the test stand consists of cryosorption pumps followed by a cryopump. A pressure of 4 x 10 -12 Torr has been achieved. 7 refs., 5 figs

  3. Note on a simple test method for estimaing J/sub Ic/

    International Nuclear Information System (INIS)

    Whipple, T.A.; McHenry, H.I.

    1980-01-01

    Fracture toughness testing is generally a time-consuming and expensive procedure; therefore, there has been a significant amount of effort directed toward developing an inexpensive and rapid method of estimating the fracture toughness of materials. In this paper, a simple method for estimating J/sub Ic/ through the use of small, notched, bend bars is evaluated. The test only involves the measurement of the energy necessary to fracture the sample. Initial tests on Fe-18Cr-3Ni-13Mn and 304L stainless steel at 76 and 4 0 K have yielded results consistent with other fracture toughness tests, for materials in the low- to medium-toughness range

  4. Application of advanced non-destructive testing for testing the integrity of concrete foundations

    International Nuclear Information System (INIS)

    Nguyen Le Son; Nguyen Phuoc Lan; Pham The Hung; Vu Huy Thuc

    2004-01-01

    Solid foundations are integral important part of any structures. Obtaining accurate and timely information on the integrity of structural foundations is essential for project progress and success. Cross-hole sonic method has been widely accepted for quality assurance and quality control on projects with deep foundations, and to assess the integrity of other civil engineering structures. Under the framework of the basic VAEC project (2003) and project VIE/8/013, the Cross-hole sonic method (CHM) was evaluated at Center for Nuclear Techniques, Hochiminh City (CNT). Background information on principle and general description of the method as is typically applied in the evaluation of deep foundations are also summarized. A suitable experimental model of the shaft foundations was prepared, where the artificial defects can be controlled for the Cross-hole sonic logging was conducted by measuring the propagation time of ultrasonic signals between two probes in vertical holes in a shaft. The purpose of the test program is to evaluate the ability of the cross-hole sonic method to identify the defects present in the experimental model, to evaluate the capabilities of the method and the equipped system Cs-97, to improve the presentation of test results to meet requirements for interpreting the quality of drilled shafts by processing the data of Cs-97. The cross-hole sonic testing program is describe. Summarizes the results and analysis of the cross-hole sonic logging are presented to highlight both the applicability and limitations of the method. The cross-hole sonic logging evaluation is a valuable non-destructive method in assessing the integrity of deep foundations. The cross-hole sonic logging tests successfully determined the location and extent of the built-in defects on experimental model shaft. Minimum sizes of defects can be detected were about ≥ 10 cm Cs-97. Effects of the directions, detectable sizes and natures of defects were studied. The apparent velocities

  5. Jsub(Ic)-testing of A-533 B - statistical evaluation of some different testing techniques

    International Nuclear Information System (INIS)

    Nilsson, F.

    1978-01-01

    The purpose of the present study was to compare statistically some different methods for the evaluation of fracture toughness of the nuclear reactor material A-533 B. Since linear elastic fracture mechanics is not applicable to this material at the interesting temperature (275 0 C), the so-called Jsub(Ic) testing method was employed. Two main difficulties are inherent in this type of testing. The first one is to determine the quantity J as a function of the deflection of the three-point bend specimens used. Three different techniques were used, the first two based on the experimentally observed input of energy to the specimen and the third employing finite element calculations. The second main problem is to determine the point when crack growth begins. For this, two methods were used, a direct electrical method and the indirect R-curve method. A total of forty specimens were tested at two laboratories. No statistically significant different results were obtained from the respective laboratories. The three methods of calculating J yielded somewhat different results, although the discrepancy was small. Also the two methods of determination of the growth initiation point yielded consistent results. The R-curve method, however, exhibited a larger uncertainty as measured by the standard deviation. The resulting Jsub(Ic) value also agreed well with earlier presented results. The relative standard deviation was of the order of 25%, which is quite small for this type of experiment. (author)

  6. Taxation of Foreign Foundations in Light of EU Law

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2016-01-01

    a) The article analyses why it is necessary to consider European law when national tax law is to test whether a foundation (i.e., an independent institution) domiciled in another EU/EEA country can be considered as an independent tax subject. In Denmark the qualification for tax purposes...... of a foreign foundation has so far been decided on the basis purely of national tax law. The article argues that it is necessary to consider European law in the testing because it creates a restriction on the freedom of establishment and capital movement if the foundation is not approved as the ‘beneficial...... owner’ of the income received by the foundation. Such restriction must be able to be justified on the grounds of compelling reasons, suitability and proportionality. b) There has been a long-standing tradition in Denmark and undoubtedly also in many other member states, for tax law to be sceptic...

  7. Advanced Laboratory Setup for Testing Offshore Foundations

    DEFF Research Database (Denmark)

    Nielsen, Søren Dam; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    2016-01-01

    This paper describes a test setup for testing small-scale offshore foundations under realistic conditions of high pore-water pressure and high impact loads. The actuator, used for loading has enough capacity to apply sufficient force and displacement to achieve both drained and undrained failure ...

  8. Stand for visual ultrasonic testing of spent fuel

    International Nuclear Information System (INIS)

    Czajkowski, W.; Borek-Kruszewska, E.

    2001-01-01

    A stand for visual and ultrasonic testing of spent fuel, constructed under Strategic Governmental Programme for management of spent fuel and radioactive waste, is presented in the paper. The stand, named 'STEND-1', built up at the Institute of Atomic Energy in Swjerk, is appointed for underwater visual testing of spent fuel elements type MR6 and WWR by means of TV-CCD camera and image processing system and for ultrasonic scanning of external surface of these elements by means of video scan immersion transducer and straight UHT connector. 'STEND-1' is built using flexible in use, high-tensile, anodized aluminum profiles. All the profiles feature longitudinal grooves to accommodate connecting elements and for the attachment of accessories at any position. They are also characterised by straight-through core bores for use with standard fastening elements and to accommodate accessory components. Stand, equipped with automatic control and processing system based on personal computer, may be manually or automatically controlled. Control system of movements of the camera in the vertical axis and rotational movement of spent fuel element permits to fix chosen location of fuel element with accuracy better than 0.1 mm. High resolution of ultrasonic method allows to record damages of outer surface of order 0.1 mm. The results of visual testing of spent fuel are recorded on video tape and then may be stored on the hard disc of the personal computer and presented in shape of photo or picture. Only selected damage surfaces of spent fuel elements are tested by means of ultrasonic scanning. All possibilities of the stand and results of visual testing of spent fuel type WWR are presented in the paper. (author)

  9. Data acquisition system for PLT Neutral Beam Test Stand

    International Nuclear Information System (INIS)

    Francis, J.E. Jr.; Hammons, C.E.

    1977-01-01

    The PLT Neutral Beam Test Stand at Oak Ridge National Laboratory was constructed to test and condition powerful neutral beam sources for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors the beam characteristics and power output to determine if the beam is operating at its design specifications. The high speed of the computer system is utilized to provide near-real-time analysis of experimental data. The analysis of the data is presented as numerical tabulation and graphic display

  10. Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

    Science.gov (United States)

    Dempsey, Paula J.; Branning, Jeremy; Wade, Damiel R.; Bolander, Nathan

    2010-01-01

    The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

  11. How well does the 30-second Chair Stand Test predict rehabilitation needs?

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Nørgaard, Birgitte; Backer Mogensen, Christian

    of functional decline. The 30-Second Chair Stand Test (30s-CST) is recommended by the Danish Health and Medicines Authority for screening of functional decline in elderly citizens living in their own home. However, its validity with hospitalized patients is undocumented, and it is unclear whether loss...... performance, e) patient-related data. Both patients and health professionals will contribute to the face validity assessment. Results The results will be available by the end of 2014. Conclusions Face validations of 30s-CST and DEMMI are relevant as validated tests for short-term hospitalized patients...

  12. IC Associated Conditions

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Click to learn more about these and ...

  13. Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John L.; Morris, Jonathan A.; Turowski, Mark P.; Franzl, Richard

    2010-01-01

    This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

  14. Cryogenics for a vertical test stand facility for testing superconducting radio frequency cavities at RRCAT

    International Nuclear Information System (INIS)

    Gupta, Prabhat Kumar; Kumar, Manoj; Kush, P.K.

    2015-01-01

    Vertical Test Stand (VTS) Facility is located in a newly constructed building of Cryo-Engineering and Cryo-Module Development Division (CCDD). This test facility is one of the important facilities to develop SCRF technologies for superconducting accelerators like Indian Spallation Neutron Source. VTS has to be used for regular testing of the Superconducting Radio Frequency (SRF) Niobium cavities at nominal frequency of 1.3 GHz/ 650 MHz at 4 K / 2 K liquid helium (LHe) bath temperatures. Testing of these cavities at 2 K evaluates cavity processing methods, procedures and would also serve as a pre-qualification test for cavity to test it in horizontal cryostat, called horizontal test stand, with other cavity components such as tuner and helium vessel. Cryogenic technologies play a major role in these cavity testing facilities. Achieving and maintaining a stable temperature of 2 K in these test stands on regular and reliable basis is a challenging task and require broad range of cryogenic expertise, large scale system level understanding and many in-house technological and process developments. Furthermore this test stand will handle large amount of liquid helium. Therefore, an appropriately designed infrastructure is required to handle such large amount of helium gas generated during the operation of VTS .This paper describes the different cryogenic design aspects, initial cryogenic operation results and different cryogenic safety aspects. (author)

  15. SEM probe of IC radiation sensitivity

    Science.gov (United States)

    Gauthier, M. K.; Stanley, A. G.

    1979-01-01

    Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.

  16. Dynamical Competition of IC-Industry Clustering from Taiwan to China

    Science.gov (United States)

    Tsai, Bi-Huei; Tsai, Kuo-Hui

    2009-08-01

    Most studies employ qualitative approach to explore the industrial clusters; however, few research has objectively quantified the evolutions of industry clustering. The purpose of this paper is to quantitatively analyze clustering among IC design, IC manufacturing as well as IC packaging and testing industries by using the foreign direct investment (FDI) data. The Lotka-Volterra system equations are first adopted here to capture the competition or cooperation among such three industries, thus explaining their clustering inclinations. The results indicate that the evolution of FDI into China for IC design industry significantly inspire the subsequent FDI of IC manufacturing as well as IC packaging and testing industries. Since IC design industry lie in the upstream stage of IC production, the middle-stream IC manufacturing and downstream IC packing and testing enterprises tend to cluster together with IC design firms, in order to sustain a steady business. Finally, Taiwan IC industry's FDI amount into China is predicted to cumulatively increase, which supports the industrial clustering tendency for Taiwan IC industry. Particularly, the FDI prediction of Lotka-Volterra model performs superior to that of the conventional Bass model after the forecast accuracy of these two models are compared. The prediction ability is dramatically improved as the industrial mutualism among each IC production stage is taken into account.

  17. Engineering design of vertical test stand cryostat

    International Nuclear Information System (INIS)

    Suhane, S.K.; Sharma, N.K.; Raghavendra, S.; Joshi, S.C.; Das, S.; Kush, P.K.; Sahni, V.C.; Gupta, P.D.; Sylvester, C.; Rabehl, R.; Ozelis, J.

    2011-01-01

    Under Indian Institutions and Fermilab collaboration, Raja Ramanna Centre for Advanced Technology and Fermi National Accelerator Laboratory are jointly developing 2K Vertical Test Stand (VTS) cryostats for testing SCRF cavities at 2K. The VTS cryostat has been designed for a large testing aperture of 86.36 cm for testing of 325 MHz Spoke resonators, 650 MHz and 1.3 GHz multi-cell SCRF cavities for Fermilab's Project-X. Units will be installed at Fermilab and RRCAT and used to test cavities for Project-X. A VTS cryostat comprises of liquid helium (LHe) vessel with internal magnetic shield, top insert plate equipped with cavity support stand and radiation shield, liquid nitrogen (LN 2 ) shield and vacuum vessel with external magnetic shield. The engineering design and analysis of VTS cryostat has been carried out using ASME B and PV Code and Finite Element Analysis. Design of internal and external magnetic shields was performed to limit the magnetic field inside LHe vessel at the cavity surface 2 shield has been performed to check the effectiveness of LN 2 cooling and for compliance with ASME piping code allowable stresses.

  18. Releveling and behavior of strap-retrofitted damaged test foundations exposed to mine subsidence

    International Nuclear Information System (INIS)

    Marino, G.G.

    1997-01-01

    Test foundation walls were constructed in an area of planned subsidence. These crawl space-sized block bearing walls were located in the tension zone of a longwall panel. The test walls were 1.2 m (40 ft) long and were vertically loaded on top with soil binds to simulate the weight of a house. As the longwall proceeded past these test foundations, subsidence movements damaged the test structures. These damaged foundations were then structurally and aesthetically repaired by using a steel strap retrofit and applying a cementitious surface coating. The repaired test foundations underwent significant subsequent subsidence as an adjacent longwall was mined beneath. The response of the repaired foundation is summarized in this paper. The steel straps were also used to relevel another set of the test foundations after they were tilted and damaged by subsidence. First, the straps were applied to the block bearing walls, and then wall jacks were used to lift the upper portion of the walls to a level position. This releveling procedure is outlined with the results

  19. Complex Adaptive Systems of Systems (CASoS) engineering and foundations for global design.

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, Nancy S.; Finley, Patrick D.; Beyeler, Walter Eugene; Brown, Theresa Jean; Linebarger, John Michael; Moore, Thomas W.; Glass, Robert John, Jr.; Maffitt, S. Louise; Mitchell, Michael David; Ames, Arlo Leroy

    2012-01-01

    Complex Adaptive Systems of Systems, or CASoS, are vastly complex ecological, sociological, economic and/or technical systems which must be recognized and reckoned with to design a secure future for the nation and the world. Design within CASoS requires the fostering of a new discipline, CASoS Engineering, and the building of capability to support it. Towards this primary objective, we created the Phoenix Pilot as a crucible from which systemization of the new discipline could emerge. Using a wide range of applications, Phoenix has begun building both theoretical foundations and capability for: the integration of Applications to continuously build common understanding and capability; a Framework for defining problems, designing and testing solutions, and actualizing these solutions within the CASoS of interest; and an engineering Environment required for 'the doing' of CASoS Engineering. In a secondary objective, we applied CASoS Engineering principles to begin to build a foundation for design in context of Global CASoS

  20. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  1. 2.5 Gb/s laser-driver GaAS IC

    DEFF Research Database (Denmark)

    Riishøj, Jesper

    1993-01-01

    A laser-diode driver GaAs IC incorporating an optional NRZ/RZ (non-return-to-zero/return-to-zero) conversion facility, having ECL (emitter-coupled logic) and SCFL (source-coupled FET logic)-compatible inputs and providing a 0-60-mA adjustable output current into a 50-Ω/5-V termination at bit rates...... obtained. To verify laser driving performance a back-to-back optical-fiber transmission experiment was performed, giving good optical eye diagrams at 2.5 Gb/s. The electrooptical interplay between laser-diode driver and laser-diode has been demonstrated using SPICE simulations...... up to 2 Gb/s NRZ and maintaining a clear eye opening of 50 mA at 2.5 Gb/s NRZ bit rate has been designed, using a commercial 1-μm gate-length (Fτ=12 GHz) GaAs MESFET foundry service. The high maximum output current is obtained by implementing the output driver as a cascode differential amplifier...

  2. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    Science.gov (United States)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  3. K/sub Ic/ and J/sub Ic/ of Westerly granite: effects of thickness and in-plane dimensions

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Lutz, T.J.

    1978-01-01

    An investigation is described in which tensile properties, fracture toughness, and critical J integral are measured for Westerly granite, a rock that is widely used in rock mechanics studies. This was primarily a parameter sensitivity study in which the effects of specimen dimensions and testing techniques were assessed. It is hoped that this study will aid in establishing tentative standards and guidelines for fracture toughness testing of rock as well as indicate the feasibility of using a J integral fracture criterion for this material. ASTM standard specimen configurations of the compact and bend types were tested with compact specimens ranging in width from W = 25.4 mm to W = 406.4 mm (0.5T to 8T) and with thickness ranging from 13 mm to 100 mm. A series of 4T compact specimens were tested to assess the effects of thickness and fatigue precracking. Techniques are described that enable several values of K/sub Ic/, a complete J vs crack growth curve, and a J/sub Ic/ value to be obtained from each sample. Direct-pull tension tests on shaped specimens of Westerly granite are described which indicate a high degree of nonlinear, inelastic behavior. This fact raises questions about the use of LEFM, but the J/sub Ic/ data presented appear to validate the K/sub Ic/ measurements

  4. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. The authors will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and a Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 microm resolution, for scanning wires and slits has begun

  5. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. We will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 μm resolution, for scanning wires and slits has begun. (author)

  6. Set-up and Test Procedure for Suction Installation and Uninstallation of Bucket Foundation

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna

    This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use of......) and loading frame used for those tests have been already used for axially static and cyclic loading of piles (Thomassen, 2015a) and for axially static and cyclic loading of bucket foundation (Vaitkunaite et al., 2015).......This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use...... of suction under the bucket lid or by applying additional force through the hydraulic piston, forcing the bucket to penetrate into the soil. Tests for uninstallation are performed also with the use of water pressure, as a reverse process to the suction installation. Both installation and uninstallation tests...

  7. Cryomdoule Test Stand Reduced-Magnetic Support Design at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Chandrasekaran, Saravan Kumar [Fermilab; Crawford, Anthony [Fermilab; Harms, Elvin [Fermilab; Leibfritz, Jerry [Fermilab; Wu, Genfa [Fermilab

    2016-06-01

    In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be 2.7 x 10¹⁰. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.

  8. The Implications Related to Different IC, Different Projects and Different Thinking Addressing the Common Core of IC

    DEFF Research Database (Denmark)

    Lindgren, Peter; Saghaug, Kristin Margrethe

    2009-01-01

    challenge the development of IC: - The IC at the organizational level seems to diminish when innovation gets highly dispersed and is operated outside the core of the organization - The attractiveness of the organization to different ICA, which is one fundament to sustainable and successful innovation, seems...... to fall when the IC at the organizational core level diminishes The objective of this paper is therefore to understand 1) How the IC at the organizational core level may continue to be developed, when at the same time innovation is taking place in dispersed groups and projects. 2) How to motivate...... the different ICA´s to bring learning and knowledge back to the core with the purpose to develop IC at the organizational core level....

  9. J-2 Engine ready to go into test stand

    Science.gov (United States)

    1965-01-01

    Two technicians watch carefully as cables prepare to lift a J-2 engine into a test stand. The J-2 powered the second stage and the third stage of the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  10. Using GIFTS on the Cray-1 for the large coil test facility test: stand design analysis

    International Nuclear Information System (INIS)

    Baudry, T.V.; Gray, W.H.

    1981-06-01

    The GIFTS finite element program has been used extensively throughout the Large Coil Test Facility (LCTF) test stand design analysis. Effective use has been made of GIFTS both as a preprocessor to other finite element programs and as a complete structural analysis package. The LCTF test stand design involved stress analysis ranging from simple textbook-type problems to very complicated three-dimensional structural problems. Two areas of the design analysis are discussed

  11. Stand development and reliability tests of the thermal monitoring means for NPP

    International Nuclear Information System (INIS)

    Nalivaev, V.I.; Nikul'shin, V.S.; Kichigin, A.B.; Dirin, V.F.

    2003-01-01

    The paper is devoted to the reliability tests of thermoelectric thermometers and resistance thermometers during their operation in the nominal mode. Five stands Reliability are developed and operate for realization of tests of all manufactured thermal converters. delivered at NPP. Description of all stands are presented [ru

  12. Pile foundation response in liquefiable soil deposit during strong earthquakes. ; Centrifugal test for pile foundation model and correlation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Y.; Miura, K. (Kajima Corp., Tokyo (Japan)); Scott, R.; Hushmand, B. (California Inst. of Technology, California, CA (United States))

    1992-09-30

    For the purpose of studying the pile foundation response in liquefiable soil deposit during earthquakes, a centrifugal loading system is employed which can reproduce the stress conditions of the soil in the actual ground, and earthquake wave vibration tests are performed in dry and saturated sand layers using a pile foundation model equipped with 4 piles. In addition, the result of the tests is analyzed by simulation using an analytic method for which effective stress is taken into consideration to investigate the effectiveness of this analytical model. It is clarified from the result of the experiments that the bending moment of the pile and the response characteristics of the foundation in the pile foundation response in saturated sand are greatly affected by the longer period of acceleration wave form of the ground and the increase in the ground displacement due to excess pore water pressure buildup. It is shown that the analytical model of the pile foundation/ground system is appropriate, and that this analytical method is effective in evaluating the seismic response of the pile foundation in nonlinear liquefiable soil. 23 refs., 21 figs., 3 tabs.

  13. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    Science.gov (United States)

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  14. Test Procedure for Axially Loaded Bucket Foundations in Sand (Large Yellow Box)

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina

    This is a practical guide for preparing the soil, running a CPT test, installing a scaled bucket foundation model and running a test in the large yellow sand box cos(Kristina) in the geotechnical laboratory at Aalborg University. The test procedure is used for the examination of statically...... and cyclically axially loaded bucket foundation model In dense sand. The foundation model in scale of approximately 1:10 compared to the prototype size. The guide describes the step-by-step procedure for tests with and without surface pressure. A detailed description of test setup using the large yellow sand box...... for a monopile testing was provided by Thomassen (2015a), procedure for monopile testing can be found in Thomassen (2015b), while safety instructions were given by Vaitkunaite et al. (2014)....

  15. PENGARUH IC TERHADAP KINERJA KEUANGAN PERUSAHAAN PERBANKAN PERIODE 2005-2007

    Directory of Open Access Journals (Sweden)

    Subkhan -

    2012-03-01

    Full Text Available Tujuan dari penelitian ini adalah untuk meneliti pengaruh intellectual capital (IC perusahaan pada kinerja keuangan mereka. Penelitian ini menggunakan Public Framework dan data dari 57 sektor perbankan Indonesia yang tercatat antara tahun 2005 dan 2007 pada Indonesian Stock Exchange. Penelitian ini menggunakan partial least square (PLS untuk menganalisis data. 3 elemen IC dan kinerja perusahaan dites dalam penelitian ini. Hasilnya memperlihatkan bahwa IC dan kinerja keuangan mempunyai pengaruh yang signifikan, VACA mempunyai pengaruh yang signifikan terhadap kinerja keuangan, VAHU mempuyai pengaruh yang signifikan  terhadap kinerja keuangan, dan STVA mempunyai pengaruh yang signifikan terhadap kinerja keuangan. Abstract The objective of this study is to investigate the influence of firm’s intellectual capital (IC on their financial performance. This paper uses Public Framework and data from 57 Indonesian banking sectors listed between 2005 and 2007 on the Indonesian Stock Exchange. This study uses partial least square (PLS for data analysis. Three elements of IC and company performances are tested by this study. The results show that IC and financial performance have significant influence, VACA has significant influence to financial performance, VAHU has significant influence to financial performance, and STVA has significant influence to financial performance.Keywords: intellectual capital; financial performance

  16. Recent Progress in Planetary Laboratory Astrophysics achieved with NASA Ames' COSmIC Facility

    Science.gov (United States)

    Salama, Farid; Sciamma-O'Brien, Ella; Bejaoui, Salma

    2016-10-01

    We describe the characteristics and the capabilities of the laboratory facility, COSmIC, that was developed at NASA Ames to generate, process and analyze interstellar, circumstellar and planetary analogs in the laboratory [1]. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate various space environments such as planetary atmospheres. COSmIC integrates a variety of state-of-the-art instruments that allow forming, processing and monitoring simulated space conditions for planetary, circumstellar and interstellar materials in the laboratory. The COSmIC experimental setup is composed of a Pulsed Discharge Nozzle (PDN) expansion, that generates a plasma in the stream of a free supersonic jet expansion, coupled to two high-sensitivity, complementary in situ diagnostics: a Cavity Ring Down Spectroscopy (CRDS) and laser induced fluorescence (LIF) systems for photonic detection [2, 3], and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection [4].Recent results obtained using COSmIC will be highlighted. In particular, the progress that has been achieved in an on-going study investigating the formation and the characterization of laboratory analogs of Titan's aerosols generated from gas-phase molecular precursors [5] will be presented. Plans for future laboratory experiments on planetary molecules and aerosols in the growing field of planetary laboratory astrophysics will also be addressed, as well as the implications of studies underway for astronomical observations.References: [1] Salama F., in Organic Matter in Space, IAU S251, Kwok & Sandford eds, CUP, S251, 4, 357 (2008).[2] Biennier L., Salama, F., Allamandola L., & Scherer J., J. Chem. Phys., 118, 7863 (2003)[3] Tan X, & Salama F., J. Chem. Phys. 122, 84318 (2005)[4] Ricketts C., Contreras C., Walker, R., Salama F., Int. J. Mass Spec, 300

  17. Software testing an ISTQB-BCS certified tester foundation guide

    CERN Document Server

    Hambling, Brian; Samaroo, Angelina; Thompson, Geoff; Williams, Peter; Hambling, Brian

    2015-01-01

    This practical guide provides insight into software testing, explaining the basics of the testing process and how to perform effective tests. It provides an overview of different techniques and how to apply them. It is the best-selling official textbook of the ISTQB-BCS Certified Tester Foundation Level.

  18. Setting the Foundation for Transforming the U.S. Energy System

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Jon M.; Virden, Jud W.; Walton, Terry L.; Brog, Terrence K.; Stiles, Dennis L.; Alderson, Karis P.; Melland, Jodi C.; Hobbs, Lori L.; Martinez, Sam J.; Quadrel, Marilyn J.; Quinn, Rod K.

    2008-12-29

    Setting the Foundation for Transforming the U.S. Energy System: Three Federal Action Plans for Near- and Long-term Success is a short document written for the incoming U.S. Federal Administration's Transistion Team. The document represents what we believe to be foundational elements of a broad campaign to make rapid progress towards these goals for the longterm transformation necessary to meet our national economic, security, and environmental goals. The three immediate action plans include: * Creating Tomorrow’s Electricity Infrastructure * Decarbonizing the Energy Economy *Enabling Science-Based Policy

  19. Using the Climbing Drum Peel (CDP) Test to Obtain a G(sub IC) value for Core/Facesheet Bonds

    Science.gov (United States)

    Nettles, A. T.; Gregory, Elizabeth D.; Jackson, Justin R.

    2006-01-01

    A method of measuring the Mode I fracture toughness of core/facesheet bonds in sandwich Structures is desired, particularly with the widespread use of models that need this data as input. This study examined if a critical strain energy release rate, G(sub IC), can be obtained from the climbing drum peel (CDP) test. The CDP test is relatively simple to perform and does not rely on measuring small crack lengths such as required by the double cantilever beam (DCB) test. Simple energy methods were used to calculate G(sub IC) from CDP test data on composite facesheets bonded to a honeycomb core. Facesheet thicknesses from 2 to 5 plies were tested to examine the upper and lower bounds on facesheet thickness requirements. Results from the study suggest that the CDP test, with certain provisions, can be used to find the GIG value of a core/facesheet bond.

  20. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability...

  1. Mobile test stand for evaluation of electric power plants for unmanned aircraft

    Directory of Open Access Journals (Sweden)

    Serbezov Vladimir

    2017-01-01

    Full Text Available The absence of accurate performance data is a common problem with most civilian unmanned aerial vehicle (UAV power plant producers. The reasons for this are the small size of most of the manufacturers and the high price of precise wind tunnel testing and computer simulations. To overcome this problem at Dronamics Ltd., with support from the Department of Aeronautics of TU-Sofia, a mobile test stand for evaluation of electric power plants for unmanned aircraft was developed. The stand may be used statically, or may be installed on the roof of an automobile. The measurement system of the stand is based on popular hardware that is used in radio controlled models and in general automation. The verification of the measurement system is performed by comparing static test results with data published by the manufacturer of the tested electric motor. Tests were carried out with 2 different types of propellers and the results were compared with published results for common propellers as well as with results of theoretical studies. The results are satisfactory for practical applications. The use of this type of test stands can be a cheap and effective alternative for research and development start-up companies like Dronamics.

  2. Beam Extraction for 1-MV Electrostatic Accelerator at the 300 kV Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Yu-Seok [Dongguk University, Seoul (Korea, Republic of); Kwon, Hyeok-Jung; Cho, Yong-Sub [KOMAC, Gyeongju (Korea, Republic of)

    2015-05-15

    The Korea Multipurpose Accelerator Complex (KOMAC) has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz RF power, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. A beam extraction experiment for the test stand was performed, and the beam current was measured using a faraday cup in the chamber. A beam extraction results for the RF ion source will be presented. Beam extraction from the RF ion source of the test stand is verified by measuring the beam current with a faraday cup in the chamber. Thus far NI Labview, PLC and faraday cup have been used to measure the beam current. The OPC server is useful for monitoring the PLC values. The average beam current of (a), (b) and (c) shown in figure 2 are 110.241µA, 105.8597µA and 103.5278µA respectively.

  3. Pilot Field Test: Use of a Compression Garment During a Stand Test After Long-Duration Space Flight

    Science.gov (United States)

    Laurie, S. S.; Stenger, M. B.; Phillips, T. R.; Lee, S. M. C.; Cerisano, J.; Kofman, I.; Reschke, M.

    2016-01-01

    Orthostatic intolerance (OI) is a concern for astronauts returning from long-duration space flight. One countermeasure that has been used to protect against OI after short-duration bed rest and space flight is the use of lower body and abdominal compression garments. However, since the end of the Space Shuttle era we have not been able to test crewmembers during the first 24 hours after landing on Earth. NASA's Pilot Field Test provided us the opportunity to test cardiovascular responses of crewmembers wearing the Russian Kentavr compression garment during a stand test at multiple time points throughout the first 24 hours after landing. HYPOTHESIS We hypothesized that the Kentavr compression garment would prevent an increase in heart rate (HR) >15 bpm during a 3.5-min stand test. METHODS: The Pilot Field Test was conducted up to 3 times during the first 24 hours after crewmembers returned to Earth: (1) either in a tent adjacent to the Soyuz landing site in Kazakhstan (approx.1 hr) or after transportation to the Karaganda airport (approx. 4 hr); (2) during a refueling stop in Scotland (approx.12 hr); and (3) upon return to NASA Johnson Space Center (JSC) (approx.24 hr). We measured HR and arterial pressure (finger photoplethysmography) for 2 min while the crewmember was prone and throughout 3.5 min of quiet standing. Eleven crewmembers consented to participate; however, 2 felt too ill to start the test and 1 stopped 30 sec into the stand portion of the test. Of the remaining 8 crewmembers, 2 did not wear the Russian Kentavr compression garment. Because of inclement weather at the landing site, 5 crewmembers were flown by helicopter to the Karaganda airport before initial testing and received intravenous saline before completing the stand test. One of these crewmembers wore only the portion of the Russian Kentavr compression garment that covered the lower leg and thus lacked thigh and abdominal compression. All crewmembers continued wearing the Russian Kentavr

  4. Optimisation of the test policy of stand-by systems

    International Nuclear Information System (INIS)

    Signoret, J.P.; Muron, O.; Cohen, G.

    1980-09-01

    In a nuclear power plant there are several systems which are on stand-by position as, for instance, safety systems. These stand-by systems have to be ready to start as soon as any situation for which they have be designed occurs. A test policy is then necessary in order to know the state of such a system and repair the possible failures. The tests are normally performed at regular intervals of time according to a scheduled sequence. We have already shown during the 'IIIeme Congres National de Fiabilite' held in Perros-Guirec in 1976 how it is possible in this case to find the optimum test interval leading to the best mean availability of the system. It is, in fact, possible, to improve that by considering that if the test interval is fixed 'a priori' this does not allow to take into account information we have on the system state every time [fr

  5. Could situational judgement tests be used for selection into dental foundation training?

    Science.gov (United States)

    Patterson, F; Ashworth, V; Mehra, S; Falcon, H

    2012-07-13

    To pilot and evaluate a machine-markable situational judgement test (SJT) designed to select candidates into UK dental foundation training. Single centre pilot study. UK postgraduate deanery in 2010. Seventy-four candidates attending interview for dental foundation training in Oxford and Wessex Deaneries volunteered to complete the situational judgement test. The situational judgement test was developed to assess relevant professional attributes for dentistry (for example, empathy and integrity) in a machine-markable format. Test content was developed by subject matter experts working with experienced psychometricians. Evaluation of psychometric properties of the pilot situational judgement test (for example, reliability, validity and fairness). Scores in the dental foundation training selection process (short-listing and interviews) were used to examine criterion-related validity. Candidates completed an evaluation questionnaire to examine candidate reactions and face validity of the new test. Forty-six candidates were female and 28 male; mean age was 23.5-years-old (range 22-32). Situational judgement test scores were normally distributed and the test showed good internal reliability when corrected for test length (α = 0.74). Situational judgement test scores positively correlated with the management, leadership and professionalism interview (N = 50; r = 0.43, p fair. This initial pilot study suggests that a situational judgement test is an appropriate and innovative method to measure professional attributes (eg empathy and integrity) for selection into foundation training. Further research will explore the long-term predictive validity of the situational judgement test once candidates have entered training.

  6. Development of socketed foundations for S3X5.7 posts.

    Science.gov (United States)

    2015-04-01

    The objective of this study was to develop a socketed foundation for use with the S3x5.7 (S76x8.5) weak : post. The design focused on cylindrical, reinforced concrete foundations with a steel tube placed in the center for : use as the socket. The fou...

  7. New Medium-Scale Laboratory Testing of Bucket Foundation Capacity in Sand

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    2014-01-01

    This article presents a new testing rig for axially loaded bucket foundations. The medium-scale physical model gives the ability to examine the influence of axial tensile, compressive as well as cyclic loading on bucket foundations subjected to various levels of overburden stress. The properties...

  8. Development of brain injury criteria (BrIC).

    Science.gov (United States)

    Takhounts, Erik G; Craig, Matthew J; Moorhouse, Kevin; McFadden, Joe; Hasija, Vikas

    2013-11-01

    Rotational motion of the head as a mechanism for brain injury was proposed back in the 1940s. Since then a multitude of research studies by various institutions were conducted to confirm/reject this hypothesis. Most of the studies were conducted on animals and concluded that rotational kinematics experienced by the animal's head may cause axonal deformations large enough to induce their functional deficit. Other studies utilized physical and mathematical models of human and animal heads to derive brain injury criteria based on deformation/pressure histories computed from their models. This study differs from the previous research in the following ways: first, it uses two different detailed mathematical models of human head (SIMon and GHBMC), each validated against various human brain response datasets; then establishes physical (strain and stress based) injury criteria for various types of brain injury based on scaled animal injury data; and finally, uses Anthropomorphic Test Devices (ATDs) (Hybrid III 50th Male, Hybrid III 5th Female, THOR 50th Male, ES-2re, SID-IIs, WorldSID 50th Male, and WorldSID 5th Female) test data (NCAP, pendulum, and frontal offset tests) to establish a kinematically based brain injury criterion (BrIC) for all ATDs. Similar procedures were applied to college football data where thousands of head impacts were recorded using a six degrees of freedom (6 DOF) instrumented helmet system. Since animal injury data used in derivation of BrIC were predominantly for diffuse axonal injury (DAI) type, which is currently an AIS 4+ injury, cumulative strain damage measure (CSDM) and maximum principal strain (MPS) were used to derive risk curves for AIS 4+ anatomic brain injuries. The AIS 1+, 2+, 3+, and 5+ risk curves for CSDM and MPS were then computed using the ratios between corresponding risk curves for head injury criterion (HIC) at a 50% risk. The risk curves for BrIC were then obtained from CSDM and MPS risk curves using the linear relationship

  9. THE COMPLEX OF STANDS FOR TESTING THE AIR CUSHION CHASSIS OF AIRCRAFT AND VEHICLES

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available This article deals with a set of stands made in NIMK TSAGI for testing and creating the air cushion chassis for the aircraft and vehicles. It allows to fully embrace the process of developing and constructing the air cushion chassis for air- craft and solve problems relating to peculiarities of such aircraft on the takeoff, landing and movement in the elementary prepared and unprepared soil runways, flat terrain and water areas. The complex includes: the experimental installation to study aeroelasticity phenomena of the chassis in the extending and retracting process with simulation of aircraft and ekran- oplane takeoff and landing modes in the air flow, including the wind tunnels; the experimental stand with vertical screen for testing of ekranoplane models in T-5 wind tunnel of NIMC TsAGI, permitting to simultaneously vary the model’s posi- tion relatively to the screen, roll, pitch (angle of attack, and banking; mobile experimental stand with contact crawler gear, for experimental determination and comparative evaluation of the chassis with different patterns of formation and air cush- ion fences for all-year-round testing in natural conditions at elementary-prepared and unprepared sites and water areas. Based on mathematical simulation of flow past in the wind tunnel the possibility of use booth stand with vertical screen and experimental installation to study aeroelasticity phenomena of the chassis for experimental studies, respectively, by defini- tion of the aerodynamic characteristics of forces and moments of the air cushion aircraft and ekranoplanes models and the research of phenomena of aeroelasticity of flexible fencing is substantiated.

  10. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  11. Construction of a test stand for the measurement of the light output uniformity of CALIFA crystals

    Energy Technology Data Exchange (ETDEWEB)

    Susenburger, Markus; Ignatov, Alexander; Kroell, Thorsten [Technische Universitaet Darmstadt, Darmstadt (Germany)

    2016-07-01

    Currently, the Facility for Antiproton and Ion Research (FAIR) at GSI in Darmstadt is under construction. One experiment at GSI and FAIR is called Reactions with Relativistic Radioactive Beams (R{sup 3}B). A key component of the R{sup 3}B is the CALorimeter for In Flight detection of γ-rays and light charged pArticles (CALIFA), which will surround the R{sup 3}B target chamber and will be capable of the detection of γ-rays in a wide energy range from 100 keV to 30 MeV as well as of light charged particles. CALIFA is built out of two parts, the so called CALIFA barrel and CALIFA endcap. The barrel consists of 1952 CsI(Tl) detector crystals which have to fulfill several specifications. One of these specifications is the uniformity of the light output. Depending on the location of the deposited energy, the crystal's light output varies due to optical focusing effects. This behavior can be manipulated by lapping the crystal's surface. The aim of this work is the development of a test stand which will check if the crystals match the requirements according to the light output uniformity. Because of the large number of crystals needed to be tested, the stand automates the test procedure, which guarantees comparable test measurement for all crystals. The development and construction of this stand is reported.

  12. Is Rorty’s Neopragmatism the “Real” Foundation of Medical Ethics: a Search for Foundational Principles

    Science.gov (United States)

    Branch, William T

    2006-01-01

    Principlism, the predominate approach to bioethics, has no foundational principles. This absence of foundations reflects the general intellectual climate of postmodern relativism. Even America’s foremost public philosopher, Richard Rorty, whose pragmatism might suggest a philosophy of commonsense, seems to be swimming in the postmodern swamp. Alternatively, principlism’s architects, Beauchamp and Childress, suggest a constantly evolving reflective equilibrium with some basis in common morality as a workable framework for twenty-first century bioethics. The flaw in their approach is failure to conform to real doctors’ and patients’ experiences. Real doctors adopt a scientific paradigm that assumes an objective reality. Patients experience real suffering and seek effective cures, treatments, palliation and solace. The foundation of medical ethics should be that doctors altruistically respond to their patients’ suffering using scientifically acceptable modalities. Compassion, caring, and respect for human dignity are needed as guides in addition to justice, beneficence, nonmaleficence and respect for autonomy. PMID:18528478

  13. Clock- and data-recovery IC with demultiplexer for a 2.5 Gb/s ATM physical layer controller

    DEFF Research Database (Denmark)

    Hansen, Flemming; Salama, C.A.T.

    1996-01-01

    A Clock- and Data-Recovery (CDR) IC for a Physical Layer Controller in an Asynchronous Transfer Mode (ATM) system operating at a bit rate of 2.488 Gb/s is presented. The circuit was designed and fabricated in a 0.8 μm BiCMOS process featuring 13 GHz fT bipolar transistors. Clock-recovery is accom......A Clock- and Data-Recovery (CDR) IC for a Physical Layer Controller in an Asynchronous Transfer Mode (ATM) system operating at a bit rate of 2.488 Gb/s is presented. The circuit was designed and fabricated in a 0.8 μm BiCMOS process featuring 13 GHz fT bipolar transistors. Clock...

  14. 1 MW, 352.2 MHz, CW and Pulsed RF test stand

    International Nuclear Information System (INIS)

    Badapanda, M.K.; Tripathi, Akhilesh; Upadhyay, Rinki; Tyagi, Rajiv; Hannurkar, P.R.

    2011-01-01

    A 1 MW, 352.2 MHz, RF test stand based on Thales make TH 2089 klystron amplifier is being developed at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore for characterization and qualification of RF components, cavities and related subsystems. Provision to vary RF power from 50 kW to 1 MW with adequate flexibility for testing wide range of HV components, RF components and cavities is incorporated in this test stand. The paper presents a brief detail of various power supplies like high voltage cathode bias power supply, modulating anode power supply, filament power supply, electromagnet power supplies and ion pump power supplies along with their interconnections for biasing TH 2089 klystron amplifier. A digital control and interlock system is being developed to realize proper sequence of operation of various power supplies and to monitor the status of crucial parameters in this test set up. This RF test stand will be a unique national facility, capable of providing both CW and pulse RF power for realizing reliable RF power sources for various projects including the development of high energy proton linac under ADSS program of the Department of Atomic Energy. (author)

  15. Construction, commissioning and initial operation of 2400W refrigerator and cold test stand for CDM testing

    International Nuclear Information System (INIS)

    Dubbs, J.D.; Kreinbrink, K.

    1994-01-01

    Air Products and CVI collaborated to design, construct and commission a refrigerator, test stands and integrated control system for the General Dynamics Collider Dipole Magnet Cold Test Facility (CTF) in Hammond, LA. The original project schedule required the cold test facility to be operational within 17 months of the notice to proceed. Midway through the project, changes in General Dynamics magnet testing requirements necessitated doubling the plant capacity, but the on stream date for the initial capacity increment could not be relaxed. The Air Products/CVI team had to adapt the project execution strategy to mitigate the schedule impact of the expansion in a cost effective manner without impacting system functionality, quality or safety. An equally challenging aspect of the job was that the (CTF) was being designed while several major systems that would interface with the CTF were being engineered. General Dynamics, Air Products and CVI had to work very closely to manage the interface issues. The teams efforts were very successful. The Hammond refrigerator/liquifier was started up on schedule. The first two test stands are currently being commissioned and will be on stream just six weeks later than the pre-expansion schedule target and all four test stands will be operational in time to support General Dynamics magnet testing requirements

  16. Large source test stand for H-(D-) ion source

    International Nuclear Information System (INIS)

    Larson, R.; McKenzie-Wilson, R.

    1981-01-01

    The Brookhaven National Laboratory Neutral Beam Group has constructed a large source test stand for testing of the various source modules under development. The first objective of the BNL program is to develop a source module capable of delivering 10A of H - (D - ) at 25 kV operating in the steady state mode with satisfactory gas and power efficiency. The large source test stand contains gas supply and vacuum pumping systems, source cooling systems, magnet power supplies and magnet cooling systems, two arc power supplies rated at 25 kW and 50 kW, a large battery driven power supply and an extractor electrode power supply. Figure 1 is a front view of the vacuum vessel showing the control racks with the 36'' vacuum valves and refrigerated baffles mounted behind. Figure 2 shows the rear view of the vessel with a BNL Mk V magnetron source mounted in the source aperture and also shows the cooled magnet coils. Currently two types of sources are under test: a large magnetron source and a hollow cathode discharge source

  17. F-15B ACTIVE test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the underside of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept. The twin-engine F-15 research aircraft is equipped with new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. They give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. Ground testing during the first two weeks of November 1995 went well, and flight tests began in March 1996. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  18. Preliminary I&C Design for LORELEI

    International Nuclear Information System (INIS)

    Korotkin, S.; Kaufman, Y.; Guttmann, E. B.; Levy, S.; Amidan, D.; Gdalyho, B.; Cahana, T.; Ellenbogen, A.; Arad, M.; Weiss, Y.; Sasson, A.; Ferry, L.; Bourrelly, F.; Cohen, Y.

    2014-01-01

    This document summarizes the preliminary I&C design for LORELEI experiment The preliminary design deals with considerations regarding appropriate safety and service instrumentation. The determined closed loop control rules for temperature and position will be implemented in the detailed design. The Computer Aided Operator Decisions System (CAODS) will be used for prediction of hot spot temperature and thickness of oxidation layer using Baker-Just correlation. The proposed hybrid simulation system comprising of both virtual and real hardware will be in-cooperated for LORELEI verification. It will perform both integration cold tests for a partial hardware loop and virtual tests for the final I&C design

  19. Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector

    Energy Technology Data Exchange (ETDEWEB)

    Bounds, John Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-05

    This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.

  20. Foundations of the AdS5 x S5 superstring: I

    International Nuclear Information System (INIS)

    Arutyunov, Gleb; Frolov, Sergey

    2009-01-01

    We review the recent advances towards finding the spectrum of the AdS 5 x S 5 superstring. We thoroughly explain the theoretical techniques which should be useful for the ultimate solution of the spectral problem. In certain cases our exposition is original and cannot be found in the existing literature. The present part I deals with foundations of classical string theory in AdS 5 x S 5 , light-cone perturbative quantization and the derivation of the exact light-cone world-sheet scattering matrix

  1. A search for extragalactic pulsars in the local group galaxies IC 10 and Barnard’s galaxy

    International Nuclear Information System (INIS)

    Al Noori, H; Roberts, M S E; Champion, D; McLaughlin, M; Ransom, Scott; Ray, P S

    2017-01-01

    As of today, more than 2500 pulsars have been found, nearly all in the Milky Way, with the exception of ∼28 pulsars in the Small and Large Magellanic Clouds. However, there have been few published attempts to search for pulsars deeper in our Galactic neighborhood. Two of the more promising Local Group galaxies are IC 10 and NGC 6822 (also known as Barnard’s Galaxy) due to their relatively high star formation rate and their proximity to our galaxy. IC 10 in particular, holds promise as it is the closest starburst galaxy to us and harbors an unusually high number of Wolf-Rayet stars, implying the presence of many neutron stars. We observed IC 10 and NGC 6822 at 820 MHz with the Green Bank Telescope for ∼15 and 5 hours respectively, and put a strong upper limit of 0.1 mJy on pulsars in either of the two galaxies. We also performed single pulse searches of both galaxies with no firm detections. (paper)

  2. Planned Experiments on the Princeton Advanced Test Stand

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.

    2010-11-01

    The Princeton Advanced Test Stand (PATS) device is an experimental facility based on the STS-100 high voltage test stand transferred from LBNL. It consists of a multicusp RF ion source, a pulsed extraction system capable of forming high-perveance 100keV ion beams, and a large six-foot-long vacuum with convenient access for beam diagnostics. This results in a flexible system for studying high perveance ion beams relevant to NDCX-I/II, including experiments on beam neutralization by ferroelectric plasma sources (FEPS) being developed at PPPL. Research on PATS will concern the basic physics of beam-plasma interactions, such as the effects of volume neutralization on beam emittance, as well as optimizing technology of the FEPS. PATS combines the advantage of an ion beam source and a large-volume plasma source in a chamber with ample access for diagnostics, resulting in a robust setup for investigating and improving relevant aspects of neutralized drift. There are also plans for running the ion source with strongly electro-negative gases such as chlorine, making it possible to extract positive or negative ion beams.

  3. INVESTIGATION OF STRAIN STATE OF BASE OF THE FRAGMENT’S MODEL OF THE PILE FOUNDATION DURING STAGED LOADING OF ITS ELEMENTS IN THE SOIL TANK

    Directory of Open Access Journals (Sweden)

    SEDIN V. L.

    2017-04-01

    Full Text Available Summary. Purpose. Changes of stress strain state of the fragment’s model of the pile foundation’s base depending on load sequence change should be investigated. Methodology. There are laboratory three test runs of the fragment’s model of the pile foundation carried out at the soil tank, unlike staged of loading and square of weight square on the soil under the plate raft with the including of pile. Results. There are laboratory confirmations of change of strain-stress state of pile foundation base depending on its elements’ load sequence change and confirmations of the influence of piles preloading on their settlement reduction. Originality. Carried out series of tests under the spatial invert with step-by-step loading of model elements of pile foundation fragments (the II and III test runs showed that such sequence of foundation load allows it to take heavier loads under the condition of the same values of settlement. The model of pile foundation’s fragment with additional loading of pile (III test run showed that such sequence of foundation load allows it to take heavier loads in comparison to the I test run. Practical value. Upon condition of staged including of all elements of the pile foundation, prestressed strain state (additional skin frictions, around the model of the pile, at some point, which facilitates the movement of the pile’s model, not connected with the plate. There are laboratory confirmations of dependencies that the more the weight square under the plate is, the greater the displacement of pile’s fragment. This effect can be useful for preloading piles in the real building, and to help align the piles' settling within the limits of the pile field, before the transfer of operational loads.

  4. Stand tests of the grader unit AKD-2

    Energy Technology Data Exchange (ETDEWEB)

    Kocheskhov, S.M.; Bagley, A.V.; Shalkov, A.V.

    1982-01-01

    Results are presented of stand tests of a static operating grader designed for unmanned extraction of deep beds with programmed control of the unit AKD-2 according to hypsometry of the seam occurrence. Malfunctions in a number of grader assemblies are revealed and eliminated. Parameters are defined which characterize the kinematics and dynamics of the grader mechanism.

  5. Project of a test stand for cyclotron ion sources

    International Nuclear Information System (INIS)

    Buettig, H.; Dietrich, J.; Merker, H.; Odrich, H.; Preusche, S.; Weissig, J.

    1978-10-01

    In the work the construction of a test stand for testing and optimization of ion sources of the Rossendorf cyclotron U-120 is represented. The design procedure and the construction of the electromagnet, the vacuum chamber with monant, the vacuum system, the power supply and the detecting system are demonstrated. The results of calculations of the motion of ions in the magnetic field are presented. (author)

  6. The foundation of the individual‘s moral value in business ethics

    OpenAIRE

    Kavaliauskas, Tomas

    2007-01-01

    In this article the author attempts to show that in contemporary business ethics discourse the individual‘s moral value is subordinated to the value system of the organization. The foundation of the individual‘s moral value in business ethics depends on the foundation of the organizational network. For this reason the article discusses the stakeholder theory where power relationships play a role. The individual is seen through the lens of instrumental and technological management. Hu...

  7. Beam Profile Measurement of 300 kV Ion Source Test Stand for 1 MV Electrostatic Accelerator

    International Nuclear Information System (INIS)

    Park, Sae-Hoon; Kim, Yu-Seok; Kim, Dae-Il; Kwon, Hyeok-Jung; Cho, Yong-Sub

    2015-01-01

    In this paper, RF ion source, test stand of the ion source and its test results are presented. Beam profile was measured at the downstream from the accelerating tube and at the beam dump by using BPM and wire scanner. The RF ion source of the test stand is verified by measuring the total beam current with a faraday cup in the chamber. The KOMAC (KOrea Multi-purpose Accelerator Complex) has been developing a 300 kV ion source test stand for a 1 MV electrostatic accelerator. An ion source and accelerating tube will be installed in a high pressure vessel. The ion source in a high pressure vessel requires high reliability. To confirm the stable operation of the ion source, a test stand was proposed and developed. The ion source will be tested at the test stand to verify its long-term operation conditions. The test stand consists of a 300 kV high voltage terminal, a battery for the ion source power, a 60 Hz inverter, a 200 MHz RF power, a 5 kV extraction power supply, a 300 kV accelerating tube, and a vacuum system. The beam profile monitor was installed at the downstream from the accelerating tube. Wire scanner and faraday-cup was installed at the end of the chamber

  8. Beam Profile Measurement of 300 kV Ion Source Test Stand for 1 MV Electrostatic Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Yu-Seok [Dongguk University, Gyeonju (Korea, Republic of); Kim, Dae-Il; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Multipurpose Accelerator Complex, Gyeongju (Korea, Republic of)

    2015-10-15

    In this paper, RF ion source, test stand of the ion source and its test results are presented. Beam profile was measured at the downstream from the accelerating tube and at the beam dump by using BPM and wire scanner. The RF ion source of the test stand is verified by measuring the total beam current with a faraday cup in the chamber. The KOMAC (KOrea Multi-purpose Accelerator Complex) has been developing a 300 kV ion source test stand for a 1 MV electrostatic accelerator. An ion source and accelerating tube will be installed in a high pressure vessel. The ion source in a high pressure vessel requires high reliability. To confirm the stable operation of the ion source, a test stand was proposed and developed. The ion source will be tested at the test stand to verify its long-term operation conditions. The test stand consists of a 300 kV high voltage terminal, a battery for the ion source power, a 60 Hz inverter, a 200 MHz RF power, a 5 kV extraction power supply, a 300 kV accelerating tube, and a vacuum system. The beam profile monitor was installed at the downstream from the accelerating tube. Wire scanner and faraday-cup was installed at the end of the chamber.

  9. Non-radioactive stand-in for radioactive contamination. I. Non-radioactive tests

    International Nuclear Information System (INIS)

    Rohe, M.J.; Rankin, W.N.; Postles, R.L.

    1985-01-01

    Candidate non-radioactive materials for use as a stand-in for radioactive contamination during application of a high-pressure, hot water decontamination were identified and evaluated. A stand-in for radioactive contamination is needed to evaluate the decontaminability of replacement canyon cranes at the manufacturers location where actual radioactive contamination cannot be used. This evaluation was conducted using high-pressure, hot-water at 420 psi, 190 0 F, and 20 gal/min through a 1/8-in.-diam nozzle, the decontamination technique preferred by SRP Separations Department for this application. A non-radioactive stand-in for radioactive contamination was desired that would be removed by direct blast stream contact but would remain intact on surfaces where direct contact does not occur. This memorandum describes identification of candidate non-radioactive stand-in materials and evaluation of these materials in screening tests and tests with high-pressure, hot-water blasting. The following non-radioactive materials were tested: carpenter's line chalk; typing correction fluid; dye penetrant developer; latex paint with attapulyite added; unaltered latex paint; gold enamel; layout fluid; and black enamel. Results show that blue layout fluid and gold enamel have similar adherence that is within the range expected for actual radioactive contamination. White latex paint has less adherence than expected for actual radioactive contamination. The film was removed at a rate of 2 . Black enamel has more adherence than expected from actual radioactive contamination. In these tests ASTM No. 2B surfaces were harder to clean than either ASTM No. 1 or electropolished surfaces which had similar cleaning properties. A 90 0 blast angle was more effective than a 45 0 blast angle. In these tests there was no discernible effect of blast distance between 1 and 3 ft

  10. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  11. PROPOSAL FOR BUILD A TEST STAND TO THE STUDY WATER RAM BASED ON THE RECOMMENDATIONS CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Dariusz GRYGO

    2016-05-01

    Full Text Available The main aim of this article was developed of a test stand to a study physics phenomena accruing at work in a ram water based on the construction recommendations. The experience gained by a number of attempts allowed to the developed construction recommendations that allowed to adjust the test stand to perform various studies of physics phenomena occurring at the work of water ram and easy adaptions to the new requirements. The article includes: the review of the test stands on which performed the study in the history and in the present times, description of the construction recommendations of the universal test stand and the proposal of the test stand developed based on the construction recommendations. Motivation to take up this issue follows from the interest of devices that work in an unconventional way, devices used a renewable energy that can be used in household e.g. to improve their energy balance, delivery water to houses, drinking water for animals, fields irrigation, etc. Analysis of the literature of the water ram, test stands and their performance shown that it is small and typically old development in popular science form. In times of intensive search new sources of renewable energy reactivation of this type equipment may be highly probable.

  12. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Yu-Seok [Dongguk Univ.., Gyeongju (Korea, Republic of)

    2014-10-15

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand.

  13. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    International Nuclear Information System (INIS)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub; Kim, Yu-Seok

    2014-01-01

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand

  14. Testing the Foundations of Relativity Using Cryogenic Optical Resonators

    Science.gov (United States)

    Müller, H.; Braxmaier, C.; Herrmann, S.; Pradl, O.; Lämmerzahl, C.; Mlynek, J.; Schiller, S.; Peters, A.

    We present a new generation of experiments using cryogenic optical resonators(COREs) to test the foundations of relativity. The experiments test the isotropy of the speed of light (Michelson-Morley experiment), the independece of the speed of light from the velocity of the laboratory (Kennedy-Thorndike experiments), and the gravitational redshift for clocks based on an electronic transition. Compared with the best previous results, our tests have already yielded improvements up to a factor of three. Future versions promise significant improvements.

  15. John S. Bell on the foundations of quantum mechanics

    CERN Document Server

    Bell, John S; Gottfried, Kurt; Veltman, Martinus J G

    2001-01-01

    This book is the most complete collection of John S Bell's research papers, review articles and lecture notes on the foundations of quantum mechanics. Some of this material has hitherto been difficult to access. The book also appears in a paperback edition, aimed at students and young researchers. This volume will be very useful to researchers in the foundations and applications of quantum mechanics. Contents: (1) On the Problem of Hidden Variables in Quantum Mechanics; (2) On the Einstein-Podolsky-Rosen Paradox; (3) The Moral Aspect of Quantum Mechanics; (4) Introduction to the Hidden-Variabl

  16. PDC IC WELD FAILURE EVALUATION AND RESOLUTION

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P.; Howard, S.; Maxwell, D.; Fiscus, J.

    2012-04-16

    During final preparations for start of the PDCF Inner Can (IC) qualification effort, welding was performed on an automated weld system known as the PICN. During the initial weld, using a pedigree canister and plug, a weld defect was observed. The defect resulted in a hole in the sidewall of the canister, and it was observed that the plug sidewall had not been consumed. This was a new type of failure not seen during development and production of legacy Bagless Transfer Cans (FB-Line/Hanford). Therefore, a team was assembled to determine the root cause and to determine if the process could be improved. After several brain storming sessions (MS and T, R and D Engineering, PDC Project), an evaluation matrix was established to direct this effort. The matrix identified numerous activities that could be taken and then prioritized those activities. This effort was limited by both time and resources (the number of canisters and plugs available for testing was limited). A discovery process was initiated to evaluate the Vendor's IC fabrication process relative to legacy processes. There were no significant findings, however, some information regarding forging/anneal processes could not be obtained. Evaluations were conducted to compare mechanical properties of the PDC canisters relative to the legacy canisters. Some differences were identified, but mechanical properties were determined to be consistent with legacy materials. A number of process changes were also evaluated. A heat treatment procedure was established that could reduce the magnetic characteristics to levels similar to the legacy materials. An in-situ arc annealing process was developed that resulted in improved weld characteristics for test articles. Also several tack welds configurations were addressed, it was found that increasing the number of tack welds (and changing the sequence) resulted in decreased can to plug gaps and a more stable weld for test articles. Incorporating all of the process

  17. 1+-n+ ECR ION SOURCE DEVELOPMENT TEST STAND

    International Nuclear Information System (INIS)

    Donald P. May

    2006-01-01

    A test stand for the investigation of 1+-n+ charge boosting using an ECR ion sources is currently being assembled at the Texas A and M Cyclotron Institute. The ultimate goal is to relate the charge-boosting of ions of stable species to possible charge-boosting of ions of radioactive species extracted from the diverse, low-charge-state ion sources developed for radioactive ion beams

  18. Commissioning and First Results from the Fermilab Cryomodule Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; et al.

    2017-05-01

    A new test stand dedicated to SRF cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

  19. Tandem Mirror Experiment-Upgrade neutral beam test stand: A powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), a test stand was assembled to develop electronics for the neutral beam system. In the first six months of test stand use the authors operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, the focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance and development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises the final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U. They have also used the test stand to perform a series of physics experiments, including: reducing gas flow through valve and arc chamber characterization, reducing impurities by titanium gettering, and reducing streaming gas using apertures and collisional gas dynamics

  20. Dynamic behaviour of raft and pile foundations tests and computational models. Pt. 1

    International Nuclear Information System (INIS)

    Betbeder, J.; Garnier, J.C.; Gauvain, J.; Jeandidier, C.

    1981-01-01

    Pile foundations are commonly used for many types of buildings where the bearing capacity of soil is poor. For nuclear power plants buildings, however, there seems to be a fairly general reluctancy to accept design on piles, as it is considered difficult to demonstrate the safety of these foundations with respect to earthquakes, due to the relative lack of validation of the currently available aseismic design methods. Being conscious that pile foundations might be worth considering for future nuclear sites in France and that the reliability of design methods should be backed by experimental data, ELECTRICITE DE FRANCE decided in 1978 to undertake a series of tests, aimed at assessing the validity of computational models for seismic behaviour of pile foundations and trying to define better models if necessary. These tests on reduced scale structure, including various types of raft and pile foundations and different kinds of dynamic excitation (harmonic, earthquake simulation, impulsive release of a static force) have been made at the NICE airport site. The present paper deals with the general description of the tests and the first part of interpretation work, limited to in-structure harmonic excitation and earthquake simulation tests analyzed by simple spring -dashpot analytical models. The two following papers (K5-6 and K5-7) are devoted to specialized topics in relation with the interpretation of tests, i-e ground motions analysis for earthquake simulation and research work on a new computational model. Although preliminary conclusions can be drawn from the results obtained so far, further work will be necessary to reach a conclusive assessment on this difficult subject. (orig.)

  1. Ethernet-based test stand for a CAN network

    Science.gov (United States)

    Ziebinski, Adam; Cupek, Rafal; Drewniak, Marek

    2017-11-01

    This paper presents a test stand for the CAN-based systems that are used in automotive systems. The authors propose applying an Ethernet-based test system that supports the virtualisation of a CAN network. The proposed solution has many advantages compared to classical test beds that are based on dedicated CAN-PC interfaces: it allows the physical constraints associated with the number of interfaces that can be simultaneously connected to a tested system to be avoided, which enables the test time for parallel tests to be shortened; the high speed of Ethernet transmission allows for more frequent sampling of the messages that are transmitted by a CAN network (as the authors show in the experiment results section) and the cost of the proposed solution is much lower than the traditional lab-based dedicated CAN interfaces for PCs.

  2. Transient SEU characterization of analog IC's for ESA's satellite

    International Nuclear Information System (INIS)

    Harboe-Soerensen, R.; Van Dooren, J.; Guerre, F.X.; Constans, H.; Berger, G.; Hajdas, W.

    1999-01-01

    Data analysis of four self switch-off power supply events in the SOHO satellite pointed strongly in the direction of being Cosmic Ray or Proton induced. Further analysis of the relevant power supply schematics identified a number of analog IC's capable of causing or contributing to such events. This paper concentrates on the testing aspects of these analog IC's and presents the results of a Single Event Effects (SEEs) test program. Ground testing, simulating the flight conditions, were carried out at both heavy ion and proton accelerators. (authors)

  3. Fiber Optic Telemetry System for LLL High-Voltage Test Stand

    International Nuclear Information System (INIS)

    Richter, J.P.

    1977-01-01

    This paper describes the Fiber Optic Telemetry System designed to operate in the hostile particle and electromagnetic radiation environment of the High Voltage Test Stand. It discusses system criteria, components, packaging, and performance. In all tests to date, the system exceeds its design goals with very comfortable margins. It is well advanced into the fabrication stages with all crucial components tested and only straightforward TTL (Transistor Transistor Logic) circuitry to be completed

  4. ATLAS RPC performance on a dedicated cosmic ray test-stand

    International Nuclear Information System (INIS)

    Liberti, B.; Aielli, G.; Camarri, P.; Cardarelli, R.; Corradi, M.; Di Ciaccio, A.; Di Stante, L.; Palummo, L.; Pastori, E.; Salamon, A.; Santonico, R.; Solfaroli, E.

    2008-01-01

    596 RPC chambers have been assembled in the ATLAS Muon Spectrometer, covering a 7300 m 2 sensitive area with 355.000 read out channels. 1116 RPC Units were produced and tested before integration and installation on the experiment [A. Aloisio et al., 'The trigger chambers of the ATLAS muon spectrometer: production and tests', Nuclear Instruments and Methods A535 (2004) 265-271]. 192 ATLAS RPCs, the Barrel Outer Large (BOL) units were tested in INFN Roma Tor Vergata test stand

  5. NASA Ames’ COSmIC Laboratory Astrophysics Facility: Recent Results and Progress

    Science.gov (United States)

    Salama, Farid; Sciamma-O'Brien, Ella; Bejaoui, Salma

    2018-06-01

    The COSmIC facility was developed at NASA Ames to study interstellar, circumstellar and planetary analogs in the laboratory [1, 2]. COSmIC stands for “Cosmic Simulation Chamber” and is dedicated to the study of molecules, ions and nanoparticles under the low temperature and high vacuum conditions that are required to simulate space environments. COSmIC integrates a variety of instruments that allow generating; processing and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle expansion that generates a plasma in a free supersonic jet expansion coupled to high-sensitivity, complementary in situ diagnostic tools, used for the detection and characterization of the species present in the expansion: a Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection, and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection [3, 4].Recent advances achieved in laboratory astrophysics using COSmIC will be presented, in particular in the domain of the diffuse interstellar bands (DIBs) [5, 6] and the monitoring, in the laboratory, of the formation of dust grains and aerosols from their gas-phase molecular precursors in environments as varied as circumstellar outflows [7] and planetary atmospheres [8, 9, 10]. Plans for future laboratory experiments on cosmic molecules and grains in the growing field of laboratory astrophysics (NIR-MIR CRDS, Laser Induced Fluorescence spectra of cosmic molecule analogs and the laser induced incandescence spectra of cosmic grain analogs) will also be addressed as well as the implications for astronomy.References: [1] Salama F., Proceed. IAU S251, Kwok & Sandford eds. CUP, 4, 357 (2008).[2] Salama F., et al., Proceed. IAU S332, Y. Aikawa, M. Cunningham, T. Millar, eds., CUP (2018)[3] Biennier L., et al., J. Chem. Phys., 118, 7863 (2003)[4] Ricketts C. et al. IJMS, 300, 26 (2011)[5] Salama F., et al., ApJ., 728, 154 (2011)[6] EDIBLES

  6. 10th December 2010 - German Delegation from the Novartis Foundation for Sustainable Development visiting the LHC superconducting magnet test hall with Technology Department S. Russenschuck and accompanied by Adviser for Life Sciences M. Dosanjh.

    CERN Multimedia

    Maximilien Brice

    2010-01-01

    10th December 2010 - German Delegation from the Novartis Foundation for Sustainable Development visiting the LHC superconducting magnet test hall with Technology Department S. Russenschuck and accompanied by Adviser for Life Sciences M. Dosanjh.

  7. The H I chronicles of little things BCDs II: The origin of IC 10's H I structure

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, Trisha; Simpson, Caroline E.; Pokhrel, Nau Raj [Department of Physics, Florida International University, 11200 SW 8th Street, CP 204, Miami, FL 33199 (United States); Elmegreen, Bruce G. [IBM T. J. Watson Research Center, PO Box 218, Yorktown Heights, New York 10598 (United States); Johnson, Megan [CSIRO Astronomy and Space Science P.O. Box 76, Epping, NSW 1710 Australia (Australia); Nidever, David L., E-mail: trisha.l.ashley@nasa.gov, E-mail: simpsonc@fiu.edu, E-mail: npokh001@fiu.edu, E-mail: bge@us.ibm.com, E-mail: megan.johnson@csiro.au, E-mail: dnidever@umich.edu [Department of Astronomy, University of Michigan Ann Arbor, MI, 48109 (United States)

    2014-12-01

    In this paper we analyze Very Large Array (VLA) telescope and Green Bank Telescope (GBT) atomic hydrogen (H I) data for the LITTLE THINGS (Local Irregulars That Trace Luminosity Extremes, The H I Nearby Galaxy Survey; https://science.nrao.edu/science/surveys/littlethings) blue compact dwarf galaxy IC 10. The VLA data allow us to study the detailed H I kinematics and morphology of IC 10 at high resolution while the GBT data allow us to search the surrounding area at high sensitivity for tenuous H I. IC 10's H I appears highly disturbed in both the VLA and GBT H I maps with a kinematically distinct northern H I extension, a kinematically distinct southern plume, and several spurs in the VLA data that do not follow the general kinematics of the main disk. We discuss three possible origins of its H I structure and kinematics in detail: a current interaction with a nearby companion, an advanced merger, and accretion of intergalactic medium. We find that IC 10 is most likely an advanced merger or a galaxy undergoing accretion.

  8. The H I chronicles of little things BCDs II: The origin of IC 10's H I structure

    International Nuclear Information System (INIS)

    Ashley, Trisha; Simpson, Caroline E.; Pokhrel, Nau Raj; Elmegreen, Bruce G.; Johnson, Megan; Nidever, David L.

    2014-01-01

    In this paper we analyze Very Large Array (VLA) telescope and Green Bank Telescope (GBT) atomic hydrogen (H I) data for the LITTLE THINGS (Local Irregulars That Trace Luminosity Extremes, The H I Nearby Galaxy Survey; https://science.nrao.edu/science/surveys/littlethings) blue compact dwarf galaxy IC 10. The VLA data allow us to study the detailed H I kinematics and morphology of IC 10 at high resolution while the GBT data allow us to search the surrounding area at high sensitivity for tenuous H I. IC 10's H I appears highly disturbed in both the VLA and GBT H I maps with a kinematically distinct northern H I extension, a kinematically distinct southern plume, and several spurs in the VLA data that do not follow the general kinematics of the main disk. We discuss three possible origins of its H I structure and kinematics in detail: a current interaction with a nearby companion, an advanced merger, and accretion of intergalactic medium. We find that IC 10 is most likely an advanced merger or a galaxy undergoing accretion.

  9. Make-up of injector test stand (ITS-1) and preliminary results with Model-I ion source

    International Nuclear Information System (INIS)

    Matsuda, S.; Ito, T.; Kondo, U.; Ohara, Y.; Oga, T.; Shibata, T.; Shirakata, H.; Sugawara, T.; Tanaka, S.

    Constitution of the 1-st injector test stand (ITS-1) in the Thermonuclear Division, JAERI, and the performance of the Model-I ion source are described. Heating a plasma by neutral beam injection is one of the promising means in the thermonuclear fusion devices. Purpose of the test stand is to develop the ion sources used in such injection systems. The test stand was completed in February 1975, which is capable of testing the ion sources up to 12 amps at 30 kV. A hydrogen ion beam of 5.5 amps at 25 kV was obtained in the Model-I ion source

  10. Children and IC

    Science.gov (United States)

    ... Cola, and Orange Crush, for example), Kool-Aid, chocolate, and many fruits, fruit juices and drinks (including ... Guideline IC Treatments IC Diet & Self Management Physical Therapy Antidepressants Antihistamines Pentosan Polysulfate Sodium Bladder Instillations Immunosuppresants ...

  11. Tandem mirror experiment-upgrade neutral beam test stand: a powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), we assembled a test stand to develop electronics for the neutral beam system. In the first six months of test stand use we operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, our focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance andd development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises our final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U

  12. Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC

    Science.gov (United States)

    1991-01-01

    The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.

  13. Design of a quadrotor flight test stand for system identification

    CSIR Research Space (South Africa)

    Beharie, MM

    2015-01-01

    Full Text Available This paper presents the design, development and construction of a flight test stand for a quadrotor UAV. As opposed to alternate forms of UAV, the power plant in the case of the quadrotor serves a dual purpose of control and propulsion. Since...

  14. Pregnancy and IC

    Science.gov (United States)

    ... have not already done so, try to identify foods, beverages, and supplements that are irritating to your bladder ... Other Medicines Over-the-counter Medicines Pain Management Management of IC ... Diet Food Diaries Least and Most Bothersome Foods IC-Friendly ...

  15. Testing Moral Foundation Theory: Are Specific Moral Emotions Elicited by Specific Moral Transgressions?

    Science.gov (United States)

    Landmann, Helen; Hess, Ursula

    2018-01-01

    Moral foundation theory posits that specific moral transgressions elicit specific moral emotions. To test this claim, participants (N = 195) were asked to rate their emotions in response to moral violation vignettes. We found that compassion and disgust were associated with care and purity respectively as predicted by moral foundation theory.…

  16. Z-2 Suit Support Stand and MKIII Suit Center of Gravity Test

    Science.gov (United States)

    Nguyen, Tuan Q.

    2014-01-01

    NASA's next generation spacesuits are the Z-Series suits, made for a range of possible exploration missions in the near future. The prototype Z-1 suit has been developed and assembled to incorporate new technologies that has never been utilized before in the Apollo suits and the Extravehicular Mobility Unit (EMU). NASA engineers tested the Z-1 suit extensively in order to developed design requirements for the new Z-2 suit. At the end of 2014, NASA will be receiving the new Z-2 suit to perform more testing and to further develop the new technologies of the suit. In order to do so, a suit support stand will be designed and fabricated to support the Z-2 suit during maintenance, sizing, and structural leakage testing. The Z-2 Suit Support Stand (Z2SSS) will be utilized for these purposes in the early testing stages of the Z-2 suit.

  17. A Stand-Class Growth and Yield Model for Mexico’s Northern Temperate, Mixed and Multiaged Forests

    Directory of Open Access Journals (Sweden)

    José Návar

    2014-12-01

    Full Text Available The aim of this research was to develop a stand-class growth and yield model based on the diameter growth dynamics of Pinus spp. and Quercus spp. of Mexico’s mixed temperate forests. Using a total of 2663 temporary, circular-sampling plots of 1000 m2 each, nine Weibull distribution techniques of parameter estimation were fitted to the diameter structures of pines and oaks. Statistical equations using stand attributes and the first three moments of the diameter distribution predicted and recovered the Weibull parameters. Using nearly 1200 and 100 harvested trees for pines and oaks, respectively, I developed the total height versus diameter at breast height relationship by fitting three non-linear functions. The Newnham model predicted stem taper and numerical integration was done to estimate merchantable timber volume for all trees in the stand for each diameter class. The independence of the diameter structures of pines and oaks was tested by regressing the Weibull parameters and projecting diameter structures. The model predicts diameter distributions transition from exponential (J inverse, logarithmic to well-balanced distributions with increasing mean stand diameter at breast height. Pine diameter distributions transition faster and the model predicts independent growth rates between pines and oaks. The stand-class growth and yield model must be completed with the diameter-age relationship for oaks in order to carry a full optimization procedure to find stand density and genera composition to maximize forest growth.

  18. Cryogenic System for the Cryomodule Test Stand at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    White, Michael J. [Fermilab; Hansen, Benjamin [Fermilab; Klebaner, Arkadiy [Fermilab

    2017-10-09

    This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9GHz cryomodules to be used in the Linac Coherent Light Source II (LCLSII), which is an upgrade to an existing accelerator at Stanford Linear Accelerator Laboratory (SLAC). This paper will focus on the cryogenic system that extends from the helium refrigeration plant to the CMTS cave. Topics covered will include component design, installation and commissioning progress, and operational plans. The paper will conclude with a description of the heat load measurement plan.

  19. Saturn V First Stage Leaves the Dynamic Test Stand

    Science.gov (United States)

    1967-01-01

    This photo shows the Saturn V first stage being lowered to the ground following a successful test to determine the effects of continual vibrations simulating the effects of an actual launch. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  20. HESTIA Commodities Exchange Pallet and Sounding Rocket Test Stand

    Science.gov (United States)

    Chaparro, Javier

    2013-01-01

    During my Spring 2016 internship, my two major contributions were the design of the Commodities Exchange Pallet and the design of a test stand for a 100 pounds-thrust sounding rocket. The Commodities Exchange Pallet is a prototype developed for the Human Exploration Spacecraft Testbed for Integration and Advancement (HESTIA) program. Under the HESTIA initiative the Commodities Exchange Pallet was developed as a method for demonstrating multi-system integration thru the transportation of In-Situ Resource Utilization produced oxygen and water to a human habitat. Ultimately, this prototype's performance will allow for future evaluation of integration, which may lead to the development of a flight capable pallet for future deep-space exploration missions. For HESTIA, my main task was to design the Commodities Exchange Pallet system to be used for completing an integration demonstration. Under the guidance of my mentor, I designed, both, the structural frame and fluid delivery system for the commodities pallet. The fluid delivery system includes a liquid-oxygen to gaseous-oxygen system, a water delivery system, and a carbon-dioxide compressors system. The structural frame is designed to meet safety and transportation requirements, as well as the ability to interface with the ER division's Portable Utility Pallet. The commodities pallet structure also includes independent instrumentation oxygen/water panels for operation and system monitoring. My major accomplishments for the commodities exchange pallet were the completion of the fluid delivery systems and the structural frame designs. In addition, parts selection was completed in order to expedite construction of the prototype, scheduled to begin in May of 2016. Once the commodities pallet is assembled and tested it is expected to complete a fully integrated transfer demonstration with the ISRU unit and the Environmental Control and Life Support System test chamber in September of 2016. In addition to the development of

  1. Foundations of Children's Self-Concepts about Everyday Activities: Identities and Comparative Contexts

    Science.gov (United States)

    Fisher, Laurel

    2014-01-01

    Children's motivations to engage in everyday activities draw on their experiences in thinking of oneself and the activities. In theory, these personal and social realities provide the complex foundations of self-concepts. The aim of this project was to define the foundations of children's self-concepts about everyday activities; to focus…

  2. Application of IC Card License for Road Transportation in Commercial Vehicles Supervision and Service

    Directory of Open Access Journals (Sweden)

    Li Weiwei

    2016-01-01

    Full Text Available IC card electronic license for road transport includes the IC card commercial vehicle’s certificate and IC card practitioner’s qualification certificate. In China, the IC card electronic license for road transport is the electronic ID card which must be carried by each commercial vehicles and practitioners. This paper briefly introduces the basic situation, data format and security keys architecture of IC card electronic license for road transportation of China. In order to strengthen the supervision and service of commercial vehicles, this paper puts forward the overall application framework of IC card electronic license for road transport. The application examples of IC card license in the supervision of passenger station, dangerous goods transport management, governance overload and logistics park and port area management are discussed. The practical application results show that the application of IC card electronic license for road transport is an important technical means to improve the supervision ability and service quality of the road transportation industry.

  3. Abundances of Planetary Nebulae IC 418, IC 2165 and NGC 5882

    NARCIS (Netherlands)

    Pottasch, [No Value; Bernard-Salas, J; Beintema, DA; Feibelman, WA

    The ISO and IUE spectra of the elliptical nebulae NGC 5882, IC 418 and IC 2165 are presented. These spectra are combined with the spectra in the visual wavelength region to obtain a complete, extinction corrected, spectrum. The chemical composition of the nebulae is then calculated and compared to

  4. Profiles of the N II 6584 A line over the giant H II regions IC 1318b and c, NGC 7000 and IC 5070. 2

    Energy Technology Data Exchange (ETDEWEB)

    Canto, J; Johnson, P G; Meaburn, J; Mikhail, J S; Terrett, D L; White, N J [Manchester Univ. (UK). Dept of Astronomy

    1979-06-01

    Previously (Paper I) large-scale splitting of the (N II) line was discovered over an area of IC 1318b. The motions of the ionized material have now been mapped over a much larger region of this nebula and also IC 1318c. The splitting reaches a maximum value of 53 km/s over the faintest regions of IC 1318b and occurs over an area approximately > 20 pc across. However, few split (N II) lines were found over IC 1318c, but the motions of this whole ionized and neutral complex have been shown to be closely related. Wind-driven flows along neutral and ionized shells are proposed to explain the observations. Similar measurements have also been made on either side of the dark lane separating NGC 7000 from IC 5070.

  5. Is the timed loaded standing test a valid measure of back muscle endurance in people with vertebral osteoporosis?

    Science.gov (United States)

    Newman, M; Newman, R; Hughes, T; Vadher, K; Barker, K L

    2018-04-01

    Timed loaded standing (TLS) is a suggested measure of back muscle endurance for people with vertebral osteoporosis. Surface electromyography revealed back muscles work harder and fatigue during TLS. The test end-point and total time were associated with back fatigue. The findings help demonstrate the concurrent validity of the TLS test. The TLS test is suggested as a measure of back muscle endurance for patients with vertebral osteoporosis. However, to date, no study has demonstrated that TLS does measure back extensor or erector spinae (ES) muscle endurance. We used surface electromyography (sEMG) to investigate the performance of the thoracic ES muscles during TLS. Thirty-six people with vertebral osteoporosis with a mean age of 71.6 (range 45-86) years participated. sEMG recordings were made of the ES at T3 and T12 bilaterally during quiet standing (QS) and TLS. The relative (%) change in sEMG amplitude between conditions was compared. Fatigue was evaluated by analysing the change in median frequency (MF) of the sEMG signal during TLS, and the correlation between maximal TLS time and rate of MF decline was examined. Activity in the ES increased significantly during TLS at all electrode locations. During TLS, the MF declined at a mean rate of -24.2% per minute (95% C.I. -26.5 to -21.9%). The MF slope and test time were strongly correlated (r 2  = 0.71), and at test end, the final MF dropped to an average 89% (95% C.I. 85 to 93%) of initial MF. Twenty-eight participants (78%) reported fatigue was the main reason for stopping, and for eight (22%), it was pain. This study demonstrates that TLS challenges the ES muscles in the thoracic region and results in ES fatigue. Endurance time and the point at which the TLS test ends are strongly related to ES fatigue.

  6. Measuring IC following a semi-qualitative approach: An integrated framework

    Directory of Open Access Journals (Sweden)

    Chiara Verbano

    2013-09-01

    Full Text Available Purpose: Considering the different IC measures adopted in literature, the advantages of adopting semi-qualitative measures, and the lack of an agreed system for IC evaluation, the purpose of the paper is to analyse literature on IC measurement following a semi-qualitative approach, with the final intent to build an IC measurement framework. Design/methodology/approach: A literature review on IC measurement system, following a semi-qualitative approach, has been conducted and analysed, in order to re-organize and synthesize all items used in previous researches. Findings: An integrated framework emerged from this research and it constitutes an IC  measurement system, created gathering and integrating different items previously adopted in literature. Each of these variables has been organized in categories belonging to one of the three main components of IC: human capital, internal structural capital and relational capital. Originality/value: This research provides an integrated tool for IC evaluation, fostering toward a well agreed measurement system that is still lacking in literature. This framework could be interesting  not only for the academic world, which in the last two decades reveals increasing attention to IC, but also for the management of the companies, that with IC measurement can increase awareness of the firm’s value and develop internal auditing system to support the management of these assets. Moreover, it could be a useful instrument for the communication of IC value to the external stakeholders, as customers, suppliers and especially shareholders, and to investors and financial analysts.

  7. Learning to Stand: The Acceptability and Feasibility of Introducing Standing Desks into College Classrooms

    Directory of Open Access Journals (Sweden)

    Roberto M. Benzo

    2016-08-01

    Full Text Available Prolonged sedentary behavior is an independent risk factor for multiple negative health outcomes. Evidence supports introducing standing desks into K-12 classrooms and work settings to reduce sitting time, but no studies have been conducted in the college classroom environment. The present study explored the acceptability and feasibility of introducing standing desks in college classrooms. A total of 993 students and 149 instructors completed a single online needs assessment survey. This cross-sectional study was conducted during the fall semester of 2015 at a large Midwestern University. The large majority of students (95% reported they would prefer the option to stand in class. Most students (82.7% reported they currently sit during their entire class time. Most students (76.6% and instructors (86.6% reported being in favor of introducing standing desks into college classrooms. More than half of students and instructors predicted having access to standing desks in class would improve student’s “physical health”, “attention”, and “restlessness”. Collectively, these findings support the acceptability of introducing standing desks in college classrooms. Future research is needed to test the feasibility, cost-effectiveness and efficacy of introducing standing desks in college classrooms. Such studies would be useful for informing institutional policies regarding classroom designs.

  8. Field Performance of Recycled Plastic Foundation for Pipeline

    Science.gov (United States)

    Kim, Seongkyum; Lee, Kwanho

    2015-01-01

    The incidence of failure of embedded pipelines has increased in Korea due to the increasing applied load and the improper compaction of bedding and backfill materials. To overcome these problems, a prefabricated lightweight plastic foundation using recycled plastic was developed for sewer pipelines. A small scale laboratory chamber test and two field tests were conducted to verify its construction workability and performance. From the small scale laboratory chamber test, the applied loads at 2.5% and 5.0% of deformation were 3.45 kgf/cm2 and 5.85 kgf/cm2 for Case S1, and 4.42 kgf/cm2 and 6.43 kgf/cm2 for Case S2, respectively. From the first field test, the vertical deformation of the recycled plastic foundation (Case A2) was very small. According to the analysis based on the PE pipe deformation at the connection (CN) and at the center (CT), the pipe deformation at each part for Case A1 was larger than that for Case A2, which adopted the recycled lightweight plastic foundation. From the second field test, the measured maximum settlements of Case B1 and Case B2 were 1.05 cm and 0.54 cm, respectively. The use of a plastic foundation can reduce the settlement of an embedded pipeline and be an alternative construction method.

  9. Field Performance of Recycled Plastic Foundation for Pipeline

    Directory of Open Access Journals (Sweden)

    Seongkyum Kim

    2015-05-01

    Full Text Available The incidence of failure of embedded pipelines has increased in Korea due to the increasing applied load and the improper compaction of bedding and backfill materials. To overcome these problems, a prefabricated lightweight plastic foundation using recycled plastic was developed for sewer pipelines. A small scale laboratory chamber test and two field tests were conducted to verify its construction workability and performance. From the small scale laboratory chamber test, the applied loads at 2.5% and 5.0% of deformation were 3.45 kgf/cm2 and 5.85 kgf/cm2 for Case S1, and 4.42 kgf/cm2 and 6.43 kgf/cm2 for Case S2, respectively. From the first field test, the vertical deformation of the recycled plastic foundation (Case A2 was very small. According to the analysis based on the PE pipe deformation at the connection (CN and at the center (CT, the pipe deformation at each part for Case A1 was larger than that for Case A2, which adopted the recycled lightweight plastic foundation. From the second field test, the measured maximum settlements of Case B1 and Case B2 were 1.05 cm and 0.54 cm, respectively. The use of a plastic foundation can reduce the settlement of an embedded pipeline and be an alternative construction method.

  10. LAB3 Cosmic Ray Test Stand Analysis of Steel Stack Supports

    International Nuclear Information System (INIS)

    Cease, H.

    1998-01-01

    A cosmic ray test stand is being constructed at Lab 3. The stand consists of two stacks of steel plates one resting on top of the other. The top stack is composed of 6 plates of steel making an overall stack size of 34.5-inch x 40-inch x 99-inch. The bottom stack also has 6 layers of plate making an overall size of approximately 49.5-inch x 82-inch x 99-inch. The bottom stack is supported with three support legs. See drawing 3823.000ME-900428 for the individual plate orientation. The minimum support leg size and necessary welds between plates are determined.

  11. Standing down Straight: Jump Rhythm Technique's Rhythm-Driven, Community-Directed Approach to Dance Education

    Science.gov (United States)

    Siegenfeld, Billy

    2009-01-01

    "Standing down straight" means to stand on two feet with both stability and relaxation. Using standing down straight as the foundation of class work, Jump Rhythm Technique offers a fresh alternative to conventional systems of dance study. It bases its pedagogy on three behaviors: grounding the body so that it can move with power and efficiency,…

  12. The Second Stage of a Saturn V Ready For Test

    Science.gov (United States)

    1970-01-01

    This Saturn V S-II (second) stage is being lifted into position for a test at the Vehicle Assembly Building at the Kennedy Space Center. When the Saturn V booster stage (S-IC) burned out and dropped away, power for the Saturn was provided by the 82-foot-long and 33-foot-diameter S-II stage. Developed by the Space Division of North American Aviation under the direction of the Marshall Space Flight Center, the stage utilized five J-2 engines, each producing 200,000 pounds of thrust. The engines used liquid oxygen and liquid hydrogen as propellants. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  13. Introducing sit-stand desks increases classroom standing time among university students

    Directory of Open Access Journals (Sweden)

    Matthew Jerome

    2017-12-01

    Full Text Available Excessive sedentary behavior has been associated with many negative health outcomes. While an understudied health topic, there is evidence that university students are excessively sedentary. Sit-stand desks have been shown to reduce sedentary time among pre-university students (ages 5–18years and sedentary workers but have not been tested in university classrooms. This study tested the effects of introducing sit-stand desks into a university classroom on student's classroom sitting and standing behaviors. Using a cross-over design, students received access to both traditional seated desks and sit-stand desks for six weeks. Data were collected between September and December, 2016. We recruited 304 healthy undergraduate university students enrolled in one of two small (25 seats classrooms at a large Midwestern university during the fall of 2016. Average minutes of standing/hour/student, average percent class time spent standing, and the number of sit-stand transitions/student/hour were directly observed with video camera surveillance. Participants stood significantly more (p<0.001 when provided access to sit-stand desks (7.2min/h/student; 9.3% of class time spent standing compared to when they had access to seated desks (0.7min/h/student; 1.6% of class time spent standing but no differences were observed for the number of sit-stand transitions (p=0.47. Students reported high favorability for the sit-stand desks and improvements in several student engagement and affective outcomes while using the sit-stand desks. These findings support introducing sit-stand desks in university classrooms as an approach to reduce sedentary behaviors of university students. Keywords: Sedentary, University students, Sit-stand desk

  14. Static Test and Result Analysis on Different Types of Pile Composite Foundation in the Same Field

    Directory of Open Access Journals (Sweden)

    Zhao Tuo

    2015-01-01

    Full Text Available Combining with the situation of soil test site, the large scale experiment was studying about natural foundation, rammed soil-cement piles, CFG pile and gravel pil. A series of conclusions were given from p-s curve, the fitting curve, and the Angle of the stress ratio of pile-soil composite modulus. It has certain guiding significance for the design and construction of pile type, which is used in North China area.

  15. APPLICATION OF STEEL PIPE PILE LOADING TESTS TO DESIGN VERIFICATION OF FOUNDATION OF THE TOKYO GATE BRIDGE

    Science.gov (United States)

    Saitou, Yutaka; Kikuchi, Yoshiaki; Kusakabe, Osamu; Kiyomiya, Osamu; Yoneyama, Haruo; Kawakami, Taiji

    Steel sheet pipe pile foundations with large diameter steel pipe sheet pile were used for the foundation of the main pier of the Tokyo Gateway bridge. However, as for the large diameter steel pipe pile, the bearing mechanism including a pile tip plugging effect is still unclear due to lack of the practical examinations even though loading tests are performed on Trans-Tokyo Bay Highway. In the light of the foregoing problems, static pile loading tests both vertical and horizontal directions, a dynamic loading test, and cone penetration tests we re conducted for determining proper design parameters of the ground for the foundations. Design parameters were determined rationally based on the tests results. Rational design verification was obtained from this research.

  16. Simplified design of IC amplifiers

    CERN Document Server

    Lenk, John

    1996-01-01

    Simplified Design of IC Amplifiers has something for everyone involved in electronics. No matter what skill level, this book shows how to design and experiment with IC amplifiers. For experimenters, students, and serious hobbyists, this book provides sufficient information to design and build IC amplifier circuits from 'scratch'. For working engineers who design amplifier circuits or select IC amplifiers, the book provides a variety of circuit configurations to make designing easier.Provides basics for all phases of practical design.Covers the most popular forms for amplif

  17. A New 500-kV Ion Source Test Stand for HIF

    International Nuclear Information System (INIS)

    Sangster, T.C.; Ahle, L.E.; Halaxa, E.F.; Karpenko, V.P.; Oldaker, M. E.; Mitchell, J.W.; Beck, D.N.; Bieniosek, F.M.; Henestroza, E.; Kwan, J.W.

    2000-01-01

    One of the most challenging aspects of ion beam driven inertial fusion energy is the reliable and efficient generation of low emittance, high current ion beams. The primary ion source requirements include a rise time of order 1-msec, a pulse width of at least 20-msec, a flattop ripple of less than 0.1% and a repetition rate of at least 5-Hz. Naturally, at such a repetition rate, the duty cycle of the source must be greater than 108 pulses. Although these specifications do not appear to exceed the state-of-the-art for pulsed power, considerable effort remains to develop a suitable high current ion source. Therefore, we are constructing a 500-kV test stand specifically for studying various ion source concepts including surface, plasma and metal vapor arc. This paper will describe the test stand design specifications as well as the details of the various subsystems and components

  18. Introducing sit-stand desks increases classroom standing time among university students.

    Science.gov (United States)

    Jerome, Matthew; Janz, Kathleen F; Baquero, Barbara; Carr, Lucas J

    2017-12-01

    Excessive sedentary behavior has been associated with many negative health outcomes. While an understudied health topic, there is evidence that university students are excessively sedentary. Sit-stand desks have been shown to reduce sedentary time among pre-university students (ages 5-18 years) and sedentary workers but have not been tested in university classrooms. This study tested the effects of introducing sit-stand desks into a university classroom on student's classroom sitting and standing behaviors. Using a cross-over design, students received access to both traditional seated desks and sit-stand desks for six weeks. Data were collected between September and December, 2016. We recruited 304 healthy undergraduate university students enrolled in one of two small (25 seats) classrooms at a large Midwestern university during the fall of 2016. Average minutes of standing/hour/student, average percent class time spent standing, and the number of sit-stand transitions/student/hour were directly observed with video camera surveillance. Participants stood significantly more (p classrooms as an approach to reduce sedentary behaviors of university students.

  19. Guidance on the Stand Down, Mothball, and Reactivation of Ground Test Facilities

    Science.gov (United States)

    Volkman, Gregrey T.; Dunn, Steven C.

    2013-01-01

    The development of aerospace and aeronautics products typically requires three distinct types of testing resources across research, development, test, and evaluation: experimental ground testing, computational "testing" and development, and flight testing. Over the last twenty plus years, computational methods have replaced some physical experiments and this trend is continuing. The result is decreased utilization of ground test capabilities and, along with market forces, industry consolidation, and other factors, has resulted in the stand down and oftentimes closure of many ground test facilities. Ground test capabilities are (and very likely will continue to be for many years) required to verify computational results and to provide information for regimes where computational methods remain immature. Ground test capabilities are very costly to build and to maintain, so once constructed and operational it may be desirable to retain access to those capabilities even if not currently needed. One means of doing this while reducing ongoing sustainment costs is to stand down the facility into a "mothball" status - keeping it alive to bring it back when needed. Both NASA and the US Department of Defense have policies to accomplish the mothball of a facility, but with little detail. This paper offers a generic process to follow that can be tailored based on the needs of the owner and the applicable facility.

  20. Mechanical Design, Simulation, and Testing of Self-Aligning Gaussian Telescope and Stand for ITER LFS Reflectometer Diagnostic

    Science.gov (United States)

    Broughton, Rachel; Gomez, Michael; Zolfaghari, Ali; Morris, Lewis

    2016-10-01

    A self-aligning Gaussian telescope has been designed to compensate for the effect of movement in the ITER vacuum vessel on the transmission line. The purpose of the setup is to couple microwaves into and out of the vessel across the vacuum windows while allowing for both slow movements of the vessel, due to thermal growth, and rapid movements, due to vibrations and disruptions. Additionally, a test stand has been designed specifically to hold this telescope in order to imitate these movements. Consequently, this will allow for the assessment of the efficacy in applying the self-aligning Gaussian telescope approach. The motions of the test stand, as well as the stress on the telescope mechanism, have been virtually simulated using ANSYS workbench. A prototype of this test stand and self-aligning telescope will be built using a combination of custom machined parts and ordered parts. The completed mechanism will be tested at the lab in four different ways: slow single- and multi-direction movements, rapid multi-direction movement, functional laser alignment and self-aligning tests, and natural frequency tests. Once the prototype successfully passes all requirements, it will be tested with microwaves in the LFSR transmission line test stand at General Atomics. This work is supported by US DOE Contract No. DE-AC02-09CH11466.

  1. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain: What are the Clinical Implications of Pain During Testing?

    Science.gov (United States)

    Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian

    2016-05-01

    To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.

  2. A Test Stand for Ion Sources of Ultimate Reliability

    International Nuclear Information System (INIS)

    Enparantza, R.; Uriarte, L.; Romano, P.; Alonso, J.; Ariz, I.; Egiraun, M.; Bermejo, F. J.; Etxebarria, V.; Lucas, J.; Del Rio, J. M.; Letchford, A.; Faircloth, D.; Stockli, M.

    2009-01-01

    The rationale behind the ITUR project is to perform a comparison between different kinds of H - ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France).

  3. Shocked molecular hydrogen in the supernova remnant IC 443

    International Nuclear Information System (INIS)

    Burton, M.G.; Brand, P.W.J.L.; Webster, A.S.

    1988-01-01

    Emission from the υ = 1-0 S(1) line of molecular hydrogen has been mapped over a section of the supernova remnant IC 443. The emission originates in a sinuous ridge where the expanding shell of the SNR is interacting with a molecular cloud. The relative intensities of the 1-0 S(1), 1-0 S(0) and 2-1 S(1) lines at 2.1-2.2 μm were measured and found to be characteristic of shock-excitation of the gas. The ridge shows bright spots which are possibly density enhancements in the molecular cloud. The total luminosity of the molecular hydrogen lines in the mapped region is estimated to be about 1000 times the solar luminosity, making IC 443 one of the most luminous galactic molecular hydrogen sources yet detected. (author)

  4. LD to IC

    CERN Multimedia

    Association du personnel

    2010-01-01

    LC to IC – Publication of posts: Following the publication of new LD to IC posts, we regret that a large number of post descriptions are not available in both CERN official languages, English and French. Consequently, the Staff Association has decided to provide assistance to those who need it with the translation of one or more posts of interest. To do this, please contact the Staff Association secretariat, tel. 72819 or 72761 or 74224.

  5. Measurement by a cylinder test stand and tyre rolling resistance

    Directory of Open Access Journals (Sweden)

    A. Dávid

    2006-03-01

    Full Text Available Sometimes it is necessary to test how repair affects the properties of the car. These tests are carried out using a cylinder test stand. During the test the tyre is rolling between two cylinders of a small diameter. The question arises whether the rolling resistance of the tyre is the same as the rolling resistance when the wheel is rolling on the plane. If it is not the same what is the reliation between tyre resistances in these two cases? It is an important answer because the change of rolling resistance can affect consumption, the highest speed, engine power and other results of measurement. The paper gives the answer to these questions and describes the method of getting this information.

  6. Application of advanced non-destructive testing to evaluate the foundation depth of the existing structures

    International Nuclear Information System (INIS)

    Nguyen Le Son; Nguyen Phuoc Lan; Pham The Hung; Vu Huy Thuc; Phan Chanh Vu; Bui Xuan Huy; Tran Thanh Luan; Nguyen Kien Chinh; Le Danh Chuan

    2004-01-01

    The applications of Parallel Seismic Test to evaluate deep foundations of the existing structures are still new in Vietnam. Under the framework of the basic VAEC project (2003) and project VIE/8/013, the parallel seismic test method (PSM) was evaluated at Center for Nuclear Techniques, Hochiminh City. Background information on principle and general description of the method as it is typically applied in the evaluation of deep foundations are also summarized. A suitable test site was selected, where the foundation depths can be controlled for the parallel seismic tests were conducted by impacting the driven piles, and the travel times down the pile, through the soil, to a receiver located in an adjacent water-filled borehole were measured. The primary objective of the test program is to evaluated the accuracy of method in determining the pile length, to evaluate the capabilities of the method and the equipped system SPL-97, to define the type of material which comprises a deep foundation, the distance of the compression wave can travel through the adjacent soil before the signal attenuates beyond recognition and the ware velocities in the various soil strata encountered. The parallel seismic testing program is described and results are presented. Parallel seismic tests, as conventionally practiced, i.e. with short distance between a structure and an access hole, can be used to define the bottom of the piles, as well as to identify the material type from the computed velocity in the structural material. The conventional approach of using changes of slop of the plot versus first arrival to identify the bottom of a deep foundation works best when the piles are in a soil with uniform stiffness and the accuracy of the evaluated depths can be obtained about ± 0.5 m. Supplementing this approach of interpretation by the examining the amplitudes of the first arrival on a plot with the same scale for all records allows one to better interpret signals in more common

  7. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  8. The oiling of ICS

    International Nuclear Information System (INIS)

    Hunter, S.

    1993-01-01

    The incident command system (ICS) works for oil spills. It should be the industry standard and some will argue that it already is. But there are a number of temptations to fiddle with it. Fueling these inclinations is the fundamental difference between oil spills and natural disasters: Oil spills make the perpetrator fix the problem - under heavy oversight. Add to this difference the public outcry that attends oil spills and the dual role of government as both helper and prosecutor. From these conditions emerge adaptations of ICS which both weaken and strengthen it. The benefits of ICS are diminished by deputy incident commanders who block unified commanders from access to section chiefs, over-zealous crisis managers who displace command post decisions or its information office, separate press offices with party line slants, government law enforcement activity mixed into spill response, nonstandard operations terminology and structure involving open-quotes containment and clean upclose quotes or open-quotes salvage,close quotes and the commingling of public and private response funds. ICS's application to oil spill response is strengthened by the use of trained unified commanders, deputy incident commanders who operate as staff rather than line, crisis managers who support on-scene objectives, joint information centers, and heavy involvement of skilled, prepared environmental assessment teams in the planning section who generate priorities, strategies, and (operationally coordinated) tactics. Technically, not all these points constitute alterations of ICS, but most do and the others come close. This mixed bag of strengthening and weakening tweaks to oil spill ICS provides an opportunity to take a new look at this faithful friend to the crisis responder

  9. Second Stage (S-II) Arrives at Marshall Space Flight Center For Testing

    Science.gov (United States)

    2004-01-01

    The business end of a Second Stage (S-II) slowly emerges from the shipping container as workers prepare to transport the Saturn V component to the testing facility at MSFC. The Second Stage (S-II) underwent vibration and engine firing tests. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  10. Design of The Test Stand for Hydraulic Active Heave Compensation System

    Directory of Open Access Journals (Sweden)

    Jakubowski Arkadiusz

    2017-01-01

    Full Text Available The article presented here described the design of a test stand for hydraulic active heave compensation system. The simulation of sea waves is realized by the use of hydraulic cylinder. A hydraulic motor is used for sea waves compensation. The hydraulic cylinder and the hydraulic motor are controlled by electrohydraulic servo valves. For the measurements Authors used displacement sensor and incremental encoder. Control algorithm is implemented on the PLC. The performed tests included hydraulic actuator and hydraulic motor step responses.

  11. Genomic clustering and homology between HET-S and the NWD2 STAND protein in various fungal genomes.

    Directory of Open Access Journals (Sweden)

    Asen Daskalov

    Full Text Available BACKGROUND: Prions are infectious proteins propagating as self-perpetuating amyloid polymers. The [Het-s] prion of Podospora anserina is involved in a cell death process associated with non-self recognition. The prion forming domain (PFD of HET-s adopts a β-solenoid amyloid structure characterized by the two fold repetition of an elementary triangular motif. [Het-s] induces cell death when interacting with HET-S, an allelic variant of HET-s. When templated by [Het-s], HET-S undergoes a trans-conformation, relocates to the cell membrane and induces toxicity. METHODOLOGY/PRINCIPAL FINDINGS: Here, comparing HET-s homologs from different species, we devise a consensus for the HET-s elementary triangular motif. We use this motif to screen genomic databases and find a match to the N-terminus of NWD2, a STAND protein, encoded by the gene immediately adjacent to het-S. STAND proteins are signal transducing ATPases which undergo ligand-induced oligomerisation. Homology modelling predicts that the NWD2 N-terminal region adopts a HET-s-like fold. We propose that upon NWD2 oligomerisation, these N-terminal extensions adopt the β-solenoid fold and template HET-S to adopt the amyloid fold and trigger toxicity. We extend this model to a putative prion, the σ infectious element in Nectria haematococca, because the s locus controlling propagation of σ also encodes a STAND protein and displays analogous features. Comparative genomic analyses indicate evolutionary conservation of these STAND/prion-like gene pairs, identify a number of novel prion candidates and define, in addition to the HET-s PFD motif, two distinct, novel putative PFD-like motifs. CONCLUSIONS/SIGNIFICANCE: We suggest the existence, in the fungal kingdom, of a widespread and evolutionarily conserved mode of signal transduction based on the transmission of an amyloid-fold from a NOD-like STAND receptor protein to an effector protein.

  12. Virtual design and qualification of IC backend structures

    NARCIS (Netherlands)

    Silfhout, van R.B.R.; Sluis, van der O.; Driel, van W.D.; Janssen, J.H.J.; Zhang, G.Q.

    2006-01-01

    For Integrated Circuit (IC) wafer backend development, process developers have to design robust backend structures that guarantee both functionality and reliability during waferfab processes, packaging, qualification tests and lifetime. Figure 1 shows a simplified diagram for the design (and

  13. Steel shear strength of anchors with stand-off base plates.

    Science.gov (United States)

    2013-09-01

    Sign and signal structures are often connected to concrete foundations through a stand-off annular base plate with a double-nut anchor bolt connection, which leaves exposed anchor bolt lengths below leveling nuts used in these connections. Cantilever...

  14. Damping Estimation of a Prototype Bucket Foundation for Offshore Wind Turbines Identified by Full Scale Testing

    DEFF Research Database (Denmark)

    Damgaard, Mads; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2013-01-01

    -3.0 MW offshore wind turbine installed on a prototype bucket foundation. The foundation and the turbine tower are equipped with a monitoring system with 15 Kinemetrics force balance accelerometers and a Digitexx acquisition system. Using free vibration decays from “rotor-stop” tests and operational modal...

  15. Simulation of design dependent failure exposure levels for CMOS ICs

    International Nuclear Information System (INIS)

    Kaul, N.; Bhuva, B.L.; Rangavajjhala, V.; van der Molen, H.; Kerns, S.E.

    1990-01-01

    The total dose exposure of CMOS ICs introduces bias-dependent parameter shifts in individual devices. The bias dependency of individual parameter shifts of devices cause different designs to behave differently under identical testing conditions. This paper studies the effect of design and bias on the radiation tolerance of ICs and presents an automated design tool that produces different designs for a logic function, and presents important parameters of each design to circuit designer for trade off analysis

  16. Standing Up for Learning: A Pilot Investigation on the Neurocognitive Benefits of Stand-Biased School Desks

    Directory of Open Access Journals (Sweden)

    Ranjana K. Mehta

    2015-12-01

    Full Text Available Standing desks have proven to be effective and viable solutions to combat sedentary behavior among children during the school day in studies around the world. However, little is known regarding the potential of such interventions on cognitive outcomes in children over time. The purpose of this pilot study was to determine the neurocognitive benefits, i.e., improvements in executive functioning and working memory, of stand-biased desks and explore any associated changes in frontal brain function. 34 freshman high school students were recruited for neurocognitive testing at two time points during the school year: (1 in the fall semester and (2 in the spring semester (after 27.57 (1.63 weeks of continued exposure. Executive function and working memory was evaluated using a computerized neurocognitive test battery, and brain activation patterns of the prefrontal cortex were obtained using functional near infrared spectroscopy. Continued utilization of the stand-biased desks was associated with significant improvements in executive function and working memory capabilities. Changes in corresponding brain activation patterns were also observed. These findings provide the first preliminary evidence on the neurocognitive benefits of standing desks, which to date have focused largely on energy expenditure. Findings obtained here can drive future research with larger samples and multiple schools, with comparison groups that may in turn implicate the importance of stand-biased desks, as simple environmental changes in classrooms, on enhancing children’s cognitive functioning that drive their cognitive development and impact educational outcomes.

  17. Beam-Plasma Interaction Experiments on the Princeton Advanced Test Stand

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I. D.; Davidson, R. C.

    2011-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the fundamental physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a 100 keV ion beam source mounted on a six-foot-long vacuum chamber with numerous ports for diagnostic access. A 100 keV Ar+ beam is launched into a volumetric plasma, which is produced by a ferroelectric plasma source (FEPS). Beam diagnostics upstream and downstream of the FEPS allow for detailed studies of the effects that the plasma has on the beam. This setup is designed for studying the dependence of charge and current neutralization and beam emittance growth on the beam and plasma parameters. This work reports initial measurements of beam quality produced by the extraction electrodes that were recently installed on the PATS device. The transverse beam phase space is measured with double-slit emittance scanners, and the experimental results are compared to WARP simulations of the extraction system. This research is supported by the U.S. Department of Energy.

  18. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  19. Use of advanced commercial ICs (COTS) for space application

    International Nuclear Information System (INIS)

    Strobel, D.J.; Czajkowski, D.R.; Layton, P.; Shanken, S.

    1999-01-01

    A product line of space-qualified radiation-tolerant ICs based on a high-volume commercial-off-the-shelf (COTS) silicon has been developed. The basic results from over 300 lots of COTS silicon, assembled and screened to Class B and Class S requirements will be presented. Intelligent use of commercial ICs engineered to improve radiation performance, is effective in introducing advanced technology to new satellite systems. Space Electronics has introduced over 125 space-qualified microelectronics standard products, that are used on over 90 space projects. (authors)

  20. Backstage: the relationship between the Rockefeller Foundation and the World Health Organization, Part I: 1940s-1960s.

    Science.gov (United States)

    Birn, A-E

    2014-02-01

    In recent years, there has been a growing debate about what role foundations should play in global health governance generally, and particularly vis-à-vis the World Health Organization (WHO). Much of this discussion revolves around today's gargantuan philanthropy, the Bill and Melinda Gates Foundation, and its sway over the agenda and modus operandi of global health. Yet such pre-occupations are not new. The Rockefeller Foundation (RF), the unparalleled 20th century health philanthropy heavyweight, both profoundly shaped WHO and maintained long and complex relations with it, even as both institutions changed over time. This article examines the WHO-RF relationship from the 1940s to the 1960s, tracing its ebbs and flows, key moments, challenges, and quandaries, concluding with a reflection on the role of the Cold War in both fully institutionalizing the RF's dominant disease-control approach and limiting its smaller social medicine efforts, even as the RF's quotidian influence at WHO diminished. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  1. Some Remarks on Foundation Pile Testing Procedures

    Science.gov (United States)

    Rybak, Jarosław

    2017-10-01

    This work presents the review of pile capacity testing techniques. In an overview, the key points in pile designing are: determination of the appropriate computational schemes, reliable data on loads and the properties of structural materials (in particular, of the soil mass, which is marked by the greatest variability). The procedure of constructing a pile foundation should include: carrying out soil tests in the scope that ensures safe designing, selecting a piling technology that is relevant both to geotechnical conditions and expected loads, drafting a piling design together with the design of load tests, setting up a testing station for further load tests, static and/or dynamic tests of pile load capacity, preceded by supplementary soil tests when the conditions of test pile installation fail to comply with the design assumptions or when the pile length exceeds the depth of the previously investigated soil, making documentation of load capacity tests (with an additional correction of the piling design), the actual piling (ongoing analysis of pile driving logs and, if necessary, testing the piles’ integrity), drawing up the as-built documentation. Unfortunately, the design is corrected after the load test have been conducted only if the piles fail to show the designed bearing capacity. The designer is then obliged to revise the design assumptions on the basis of tests results. If the test results account for the a greater bearing capacity than necessary and it would be recommendable to limit the extent of the planned (i.e. set out in the contract) piling works, usually neither the contractor nor the designer, nor even the Construction Site Supervisor, acting for the benefit of the Investor, are willing to take on the responsibility for reducing the scope of the piling works. The necessity of conducting additional control tests before and during the implementation of the construction project is often treated by the investors as an attempt at extorting extra

  2. Mark Rein•Hagen’s Foundational Influence on 21st Century Vampiric Media

    DEFF Research Database (Denmark)

    Konzack, Lars

    2015-01-01

    Mark Rein•Hagen’s role-playing game Vampire: The Masquerade, set in the World of Darkness shared universe, is foundational to the 21st Century vampire. We aim to, through the cultural analysis of how ideas have been transferred from this role-playing game to other media, clearly demonstrate Mark...... Rein•Hagen’s cultural historical significance....

  3. The Reflective Foundation

    DEFF Research Database (Denmark)

    Lunde Jørgensen, Ida

    Private foundations and cultural philanthropy by élites is viewed with increasing skepticism in recent years, begging the question of the extent to which foundations reflect on their role vis a vis wider societal norms. Through the prism of the New Carlsberg Foundation, financed by the brewery...... Carlsberg A/S, the paper seeks to elucidate the way in which one culturally significant foundation from Denmark has reflected on - and legitimated - its work and investments at critical moments in the past decades. The paper indicates a foundation with a high degree of reflection on the wider societal...

  4. Irregular Dwarf Galaxy IC 1613

    Science.gov (United States)

    2005-01-01

    Ultraviolet image (left) and visual image (right) of the irregular dwarf galaxy IC 1613. Low surface brightness galaxies, such as IC 1613, are more easily detected in the ultraviolet because of the low background levels compared to visual wavelengths.

  5. Dead-time free pixel readout architecture for ATLAS front-end IC

    CERN Document Server

    Einsweiler, Kevin F; Kleinfelder, S A; Luo, L; Marchesini, R; Milgrome, O; Pengg, F X

    1999-01-01

    A low power sparse scan readout architecture has been developed for the ATLAS pixel front-end IC. The architecture supports a dual discriminator and extracts the time over threshold (TOT) information along with a 2-D spatial address $9 of the hits associating them with a unique 7-bit beam crossing number. The IC implements level-1 trigger filtering along with event building (grouping together all hits in a beam crossing) in the end of column (EOC) buffer. The $9 events are transmitted over a 40 MHz serial data link with the protocol supporting buffer overflow handling by appending error flags to events. This mixed-mode full custom IC is implemented in 0.8 mu HP process to meet the $9 requirements for the pixel readout in the ATLAS inner detector. The circuits have been tested and the IC provides dead-time-less ambiguity free readout at 40 MHz data rate.

  6. Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test.

    Science.gov (United States)

    Doheny, Emer P; Walsh, Cathal; Foran, Timothy; Greene, Barry R; Fan, Chie Wei; Cunningham, Clodagh; Kenny, Rose Anne

    2013-09-01

    The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 with a history of falls, performed four repetitions of the FTSS in their homes. A tri-axial accelerometer was attached to the lateral thigh and used to identify each sit-stand-sit phase and sit-stand and stand-sit transitions. A second tri-axial accelerometer, attached to the sternum, captured torso acceleration. The mean and variation of the root-mean-squared amplitude, jerk and spectral edge frequency of the acceleration during each section of the assessment were examined. The test-retest reliability of each feature was examined using intra-class correlation analysis, ICC(2,k). A model was developed to classify participants according to falls status. Only features with ICC>0.7 were considered during feature selection. Sequential forward feature selection within leave-one-out cross-validation resulted in a model including four reliable accelerometer-derived features, providing 74.4% classification accuracy, 80.0% specificity and 68.7% sensitivity. An alternative model using FTSS time alone resulted in significantly reduced classification performance. Results suggest that the described methodology could provide a robust and accurate falls risk assessment. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Bucket foundations under lateral cyclic loading

    DEFF Research Database (Denmark)

    Foglia, Aligi

    failure envelopes. A jacked installation test is successfully compared with existing models. Tests of bucket foundations under lateral loading applied at different loading rates are analysed. As expected, the bearing capacity of bucket foundations under transient lateral loading increases dramatically...... documents on bearing capacity and installation of bucket foundations are reviewed and the results from the models found in literature are compared to the experimental results obtained in the current study. Monotonic tests of bucket foundations under lateral loading until failure are compared with existing...

  8. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Nekouei Shahraki

    2015-12-01

    Full Text Available The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation of test-stands delivering high calibration quality in single-shot calibration of fisheye surround-view cameras. This incorporates important geometric features from bundle-block calibration, delivers very high (sub-pixel calibration accuracy, makes possible a very fast calibration procedure (few seconds, and realizes autonomous calibration via machines. We have used the geometrical shape of a Spherical Helix (Type: 3D Spherical Spiral with special geometrical characteristics, having a uniform radius which corresponds to the uniform motion. This geometrical feature was mechanically realized using three dimensional truncated icosahedrons which practically allow the implementation of a spherical helix on multiple surfaces. Furthermore the test-stand enables us to perform many other important optical tests such as stray-light testing, enabling us to evaluate the certain qualities of the camera optical module.

  9. Elevated voltage level I{sub DDQ} failure testing of integrated circuits

    Science.gov (United States)

    Righter, A.W.

    1996-05-21

    Burn in testing of static CMOS IC`s is eliminated by I{sub DDQ} testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip. 4 figs.

  10. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Mirarchi, D.; Redaelli, S.; Scandale, W. [CERN, European Organization for Nuclear Research, Geneva 23 (Switzerland); Hall, G. [Imperial College, Blackett Laboratory, London (United Kingdom)

    2017-06-15

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going. (orig.)

  11. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    International Nuclear Information System (INIS)

    Mirarchi, D.; Redaelli, S.; Scandale, W.; Hall, G.

    2017-01-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going. (orig.)

  12. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    Science.gov (United States)

    Mirarchi, D.; Hall, G.; Redaelli, S.; Scandale, W.

    2017-06-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going.

  13. The stripping foil test stand in the Linac4 transfer line

    CERN Document Server

    Weterings, W; Noulibos, R; Sillanoli, Y; van Trappen, P

    2015-01-01

    The 160 MeV H− beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H− charge-exchange injection system. It will include a stripping foil, to convert H− into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters.

  14. The stripping foil test stand in the Linac4 transfer line

    International Nuclear Information System (INIS)

    Weterings, W.; Bracco, C.; Noulibos, R.; Sillanoli, Y.; Trappen van, P.

    2015-01-01

    The 160 MeV H - beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H - charge-exchange injection system. It will include a stripping foil, to convert H - into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters. (author)

  15. Electronics system for the 150 kV negative ion test stand at BNL

    International Nuclear Information System (INIS)

    Larson, R.A.

    1977-01-01

    The 150 kV test stand at BNL is being used to investigate the extraction, acceleration and transport problems associated with the development of intense negative ion beams. The power supplies associated with these functions as well as the control and monitoring electronics are described

  16. An Improved Weise’s Rule for Efficient Estimation of Stand Quadratic Mean Diameter

    Directory of Open Access Journals (Sweden)

    Róbert Sedmák

    2015-07-01

    Full Text Available The main objective of this study was to explore the accuracy of Weise’s rule of thumb applied to an estimation of the quadratic mean diameter of a forest stand. Virtual stands of European beech (Fagus sylvatica L. across a range of structure types were stochastically generated and random sampling was simulated. We compared the bias and accuracy of stand quadratic mean diameter estimates, employing different ranks of measured stems from a set of the 10 trees nearest to the sampling point. We proposed several modifications of the original Weise’s rule based on the measurement and averaging of two different ranks centered to a target rank. In accordance with the original formulation of the empirical rule, we recommend the application of the measurement of the 6th stem in rank corresponding to the 55% sample percentile of diameter distribution, irrespective of mean diameter size and degree of diameter dispersion. The study also revealed that the application of appropriate two-measurement modifications of Weise’s method, the 4th and 8th ranks or 3rd and 9th ranks averaged to the 6th central rank, should be preferred over the classic one-measurement estimation. The modified versions are characterised by an improved accuracy (about 25% without statistically significant bias and measurement costs comparable to the classic Weise method.

  17. ‘e-Protocol’ and IC&T:Consequences for Public Ad-Ministration’s Staff Training

    Directory of Open Access Journals (Sweden)

    Oana IUCU

    2014-12-01

    Full Text Available The current research aims at providing the academic world with a new integrated and cross-disciplinary approach to Protocol and IT&ICT – consequences for administrative staff training. The need to upgrade and update the training programs for public administration’s staff according to IC&T requirements matches the prospective expert / professional’s framework of competences. A key observation is that the litera-ture in the feld of staff training for social and insti-tutional protocol within notorious training centers focuses more on the status-quo of the desirable competences and less on technology. By means of a rather refexive set of tools, we have tried to offer some support so as to digitize the social and institutional protocol, thus promoting some software packages designed by experts in both felds. Moreover, this software is likely to sustain both training and professional development pro-grams as well as effcient specialized procedures for promotion and simulation.

  18. Studies on the pathogenesis of Aleutian disease of mink. X. demonstration of immune complexes by the /sup 125/I-C 1 q binding test after experimental infection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Peddinghaus, R [Kali-Chemie Pharma G.m.b.H., Hannover (Germany, F.R.). Abt. fuer Experimentelle Pathologie; Meyer zu Schwabedissen, H [Medizinische Hochschule Hannover (Germany, F.R.). Abt. fuer Klinische Immunologie und Bluttransfusionswesen; Kalden, J R [Erlangen-Nuernberg Univ., Erlangen (Germany, F.R.). Inst. und Poliklinik fuer Klinische Immunologie; Trautwein, G; Ueberschaer, S [Tieraerztliche Hochschule Hannover (Germany, F.R.). Inst. fuer Pathologie

    1980-01-01

    Aleutian disease (AD) of mink most closely resembles systemic lupus erythematosus (SLE) in man; both are immune complex disease. In experimental AD serum immune complexes are determined by the /sup 125/J-C 1 q-binding test using human C 1 q. Mink (n = 12) infected intraperitoneally with Aleutian disease virus (ADV), grown in fetal mink kidney cells, developed during the course of infection a mean of /sup 125/I-C 1 q serum binding equivalent to 3.62 +- 1.68 mg./ml. aggr. HGG. (aggregated human immunoglobulin). Sera of mink (n = 8) which were infected with ADV grown in L-cells showed a less marked /sup 125/I-C 1 q binding with a mean equivalent to 2.52 +- 1.43 mg./ml. aggr. HGG. In contrast control animals (n = 8) treated with non-ADV-infected mink epidermal fibroblasts or Eagle's minimal essential medium substituted with fetal calf serum only bound /sup 125/I-C 1 q equivalent to 1.02 +- 0.99 mg./ml. aggr. HGG. In mink infected with ADV propagated in fetal mink kidney cells a constant increase in the /sup 125/I-C 1 q serum binding occurred from the 4th to the 7th and 13th week after ADV infection. Mink which were infected with ADV propagated in mouse L-cells exhibited a different pattern of the /sup 125/I-C 1 q serum binding capacity with a sharp increase from the 4th to the 7th week, followed by a decline towards the 13th week post infection. The serum /sup 125/I-C 1 q binding capacity of all experimental animal groups exhibited at different times of the experiment a significant correlation with the presence of hypergammaglobulinaemia and raised ADV-antibody titers. From the data obtained it appears that the /sup 125/I-C 1 q binding test, utilizing human C 1 q, is a suitable method for the detection of circulating serum immune complexes in mink during the course of ADV-infection.

  19. Wave Forces on Windturbine Foundations

    DEFF Research Database (Denmark)

    Larsen, Brian Juul; Frigaard, Peter

    A testprogramme has been performed to determine the wave forces on two types of foundations for an offshore windturbine. the tested foundation types are a monopile and cone. Furthermore the shaft of the cone has been tested....

  20. Task 4 - EMI/RFI Issues Potentially Impacting Electromagnetic Compatibility of I&C Systems (NRCHQ6014D0015)

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Richard Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ewing, Paul D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-05-01

    The U.S. Nuclear Regulatory Commission’s (NRC’s) regulations in Part 50, “Domestic Licensing of Production and Utilization Facilities,” of Title 10 of the Code of Federal Regulations (10 CFR Part 50) state that structures, systems, and components important to safety in a nuclear power plant are to be designed to accommodate the effects of environmental conditions (i.e., remain functional under all postulated service conditions) and that design control measures such as testing are to be used to check the adequacy of design. Regulatory Guide (RG) 1.180 was developed to provide guidance to licensees and applicants on methods acceptable to the NRC staff for complying with the NRC’s regulations on design, installation, and testing practices for addressing the effects of electromagnetic and radio-frequency interference (EMI/RFI) and power surges on safety-related instrumentation and control (I&C) systems. The first revision of RG 1.180 was issued in January 2000 and a second revision was issued in October 2003*. The second revision differed from the first revision in endorsing Military Standard (MIL-STD)-461E and the International Electrotechnical Commission (IEC) Standard (Std) 61000 series of EMI/RFI test methods, extending the guidance to cover signal line testing, incorporating frequency ranges where portable communications devices are experiencing increasing use, and relaxing the operating envelopes (test levels) when experience and confirmatory research warranted. It also offered exemptions from specific test criteria based on technical considerations such as plant conditions and the intended location of the safety-related I&C equipment. Since the last revision, new requirements have been identified, associated RGs have been created and updated, and additional industry guidance has been developed. Additionally, the operational environment has changed with the increase in wireless communication technology for both personal (smartphone) and industrial

  1. A Measurement System of Electric Signals on Standing Trees

    Directory of Open Access Journals (Sweden)

    Hao TIAN

    2014-01-01

    Full Text Available The standing tree electric signal (STES, defined as the electric potential difference between standing trees and the surrounding soil, can be utilized to reflect the biological nature of the trees. This signal should be measured precisely because it can also be collected and used as the electric power energy. In this paper, the automatic measurement system of standing tree biological electric signal based on MSP430 MCU. First of all, the basic structure of the presented system is introduced and it includes three modules: amplification module of the standing tree electric signal, the acquisition and processing of the signal module and the serial communication module. Then, the performances of the built system are respectively validated by the Poplar, Planetree, and Platanus in Beijing Forestry University. The result indicated that the relative error of this system is less than 2 %. The presented system can be considered as the foundation of the subsequent study on the mechanism of the biological electric signal and the application of the biological electric energy on standing trees.

  2. Optimization of a readout board for mass assembly and light yield measurements with a cosmic ray test stand

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Phi [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    We have built a readout board prototype, equipped with SiPMs, scintillators and readout electronics for an highly granular calorimeter. The design was optimized for mass assembly due to about 8 million channels in the final detector. The prototype showed good performance in several test beams and in a cosmic ray test stand, which was built to characterize the MIP response of these kinds of boards. We show an overview of the cosmic ray test stand and measurement results for the readout board and plans for an improved 2nd generation prototype.

  3. Simultaneous detection of three lily viruses using Triplex IC-RT-PCR.

    Science.gov (United States)

    Zhang, Yubao; Wang, Yajun; Xie, Zhongkui; Yang, Guo; Guo, Zhihong; Wang, Le

    2017-11-01

    Viruses commonly infecting lily (Lilium spp.) include: Lily symptomless virus (LSV), Cucumber mosaic virus (CMV) and Lily mottle virus (LMoV). These viruses usually co-infect lilies causing severe economic losses in terms of quantity and quality of flower and bulb production around the world. Reliable and precise detection systems need to be developed for virus identification. We describe the development of a triplex immunocapture (IC) reverse transcription (RT) polymerase chain reaction (PCR) assay for the simultaneous detection of LSV, CMV and LMoV. The triplex IC-RT-PCR was compared with a quadruplex RT-PCR assay. Relative to the quadruplex RT-PCR, the specificity of the triplex IC-RT-PCR system for LSV, CMV and LMoV was 100% for field samples. The sensitivity of the triplex IC-RT-PCR system was 99.4%, 81.4% and 98.7% for LSV, CMV and LMoV, respectively. Agreement (κ) between the results obtained from the two tests was 0.968, 0.844 and 0.984 for LSV, CMV and LMoV, respectively. This is the first report of the simultaneous detection of LSV, CMV and LMoV in a triplex IC-RT-PCR assay. In particular we believe this convenient and reliable triplex IC-RT-PCR method could be used routinely for large-scale field surveys or crop health monitoring of lily. Copyright © 2017. Published by Elsevier B.V.

  4. Use of reinforced soil foundation (RSF) to support shallow foundation : summary report.

    Science.gov (United States)

    2008-05-01

    This research study investigates the potential benefits of using reinforced soil foundations to improve the bearing capacity and reduce the settlement of shallow foundations on soils. To implement this objective, a total of 117 tests, including 38 la...

  5. Immunogenicity and safety of different injection routes and schedules of IC41, a Hepatitis C virus (HCV) peptide vaccine.

    Science.gov (United States)

    Firbas, Christa; Boehm, Thomas; Buerger, Vera; Schuller, Elisabeth; Sabarth, Nicolas; Jilma, Bernd; Klade, Christoph S

    2010-03-11

    An effective vaccine would be a significant progress in the management of chronic HCV infections. This study was designed to examine whether different application schedules and injection routes may enhance the immunogenicity of the HCV peptide vaccine IC41. In this randomized trial 54 healthy subjects received either subcutaneous (s.c.) or intradermal (i.d.) vaccinations weekly (16 injections) or every other week (8 injections). One group additionally received imiquimod, an activator of the toll-like receptor (TLR) 7. The T cell epitope-specific immune response to IC41 was assessed using [(3)H]-thymidine CD4+ T cell proliferation, interferon-gamma (IFN-gamma) CD8+ and CD4+ ELIspot and HLA-A*0201 fluorescence-activated cell sorting (FACS) tetramer-binding assays. More than 60% of vaccinees responded in the CD4+ T cell proliferation assay in all groups. An HLA-A*0201 FACS tetramer-binding assay and IFN-gamma CD8+ ELIspot class I response of more than 70% was induced in four and three groups, respectively. IC41 induced significant immunological responses in all groups with responder rates of up to 100%. Interestingly, topical imiquimod was not able to enhance immunogenicity but was associated with a lower immune response. Local injection site reactions were mostly transient. Intradermal injections caused more pronounced reactions compared to s.c., especially erythema and edema. Compared to a previous study intensified dosing and/or i.d. injections enhanced the response rates to the vaccine IC41 in three assays measuring T cell function. Immunization with IC41 was generally safe in this study. These results justify testing IC41 in further clinical trials with HCV-infected individuals.

  6. Bucket Foundation Response Under Various Displacement Rates

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2016-01-01

    in a multi-bucket foundation system. The foundation model is at a scale of approximately 1:20 prototype foundation size. The tests are performed in a pressure tank with the foundation model installed in dense sand. Based on the data, the conclusion is that the bucket foundation design in a storm case should......The present testing program aims at showing the pore pressure response around a bucket foundation skirt as well as the load and displacement change due to ten different displacement rates. Research findings are useful for a numerical model calibration focusing on the design of the upwind foundation...

  7. The origins of the research on the foundations of quantum mechanics (and other critical activities) in Italy during the 1970s

    Science.gov (United States)

    Baracca, Angelo; Bergia, Silvio; Del Santo, Flavio

    2017-02-01

    We present a reconstruction of the studies on the Foundations of Quantum Mechanics carried out in Italy at the turn of the 1960s. Actually, they preceded the revival of the interest of the American physicists towards the foundations of quantum mechanics around mid-1970s, recently reconstructed by David Kaiser in a book of 2011. An element common to both cases is the role played by the young generation, even though the respective motivations were quite different. In the US they reacted to research cuts after the war in Vietnam, and were inspired by the New Age mood. In Italy the dissatisfaction of the young generations was rooted in the student protests of 1968 and the subsequent labour and social fights, which challenged the role of scientists. The young generations of physicists searched for new scientific approaches and challenged their own scientific knowledge and role. The criticism to the foundations of quantum mechanics and the perspectives of submitting them to experimental tests were perceived as an innovative research field and this attitude was directly linked to the search for an innovative and radical approach in the history of science. All these initiatives gave rise to booming activity throughout the 1970s, contributing to influence the scientific attitude and the teaching approach.

  8. Wafer level 3-D ICs process technology

    CERN Document Server

    Tan, Chuan Seng; Reif, L Rafael

    2009-01-01

    This book focuses on foundry-based process technology that enables the fabrication of 3-D ICs. The core of the book discusses the technology platform for pre-packaging wafer lever 3-D ICs. However, this book does not include a detailed discussion of 3-D ICs design and 3-D packaging. This is an edited book based on chapters contributed by various experts in the field of wafer-level 3-D ICs process technology. They are from academia, research labs and industry.

  9. Analytical Analysis and Field Test Investigation of Consolidation for CCSG Pile Composite Foundation in Soft Clay

    Directory of Open Access Journals (Sweden)

    Jin Yu

    2013-01-01

    Full Text Available Low-grade concrete-cored sand-gravel (CCSG pile composite foundation is a new kind of composite foundation for thick and soft clay ground treatment. An analytical solution was derived for calculating the consolidation process of this composite foundation by considering coefficients of horizontal permeability in smear zone, the radial flow within the sand-gravel shell, and the impervious property of concrete-cored pile. The results show that Terzaghi’s one-dimensional consolidation solution and the consolidation analytical solution of ordinary composite foundation were special cases of this solution. Curves of the average consolidation degree of the composite foundation under various nondimensional parameters were observed using the program based on the theoretical formula. Meanwhile, a series of in situ measurements including the settlement of pile and soil, the pore water pressure, and the total stress under embankment load were obtained on the CCSG pile composite foundation on a section of Zhenjiang-Liyang highway. The analyzed results show that the new style composite foundation patent technology has many advantages such as small differential postconstruction settlement (differential is not good, small is, reliable quality, high bearing capacity, and stability. And the consolidation of composite foundation is largely affected by the nondimensional parameters. The analytical solution is finally verified with the actual measurement data.

  10. Use of a unipedal standing test to assess the ambulation reacquisition time during the early postoperative stage after hip fracture in elderly Japanese: prospective study.

    Science.gov (United States)

    Murata, Koichi; Sugitani, Shigeki; Yoshioka, Hiroki; Noguchi, Takashi; Aoto, Toshiyuki; Nakamura, Takashi

    2010-01-01

    The aim of this study was to predict the ambulation reacquisition time after hip fracture in elderly people using the unipedal standing test during the early postoperative stage. Patients with an intertrochanteric fracture treated with internal fixation (n = 35) and patients with a femoral neck fracture treated with hemiarthroplasty (n = 22) were included. A unipedal standing test using the nonoperated leg was performed on days 3 and 7 after the operation. Among the patients with an intertrochanteric fracture, those with a positive result on the unipedal standing test on postoperative day (POD) 3 attained gait with parallel guide bars (BG) and walker-assisted gait (WG) significantly earlier than did patients with a negative result on the unipedal standing test. Patients with a positive result on the unipedal standing test on POD 7 attained BG, WG, and cane-assisted gait (CG) significantly earlier than did patients with a negative test. Among patients with a femoral neck fracture, those with a positive unipedal standing test result on POD 3 attained BG, WG, and CG significantly earlier than did patients with a negative test. Those with a positive test result on POD 7 attained BG, WG, and CG significantly earlier than did patients with a negative test. The unipedal standing test given during the early postoperative stage is a good test for predicting the ambulation reacquisition time. Moreover, it gives information that can help determine the need for subacute rehabilitation and about discharge planning and health service provision.

  11. EVIDENCE FOR AN INTERACTION IN THE NEAREST STARBURSTING DWARF IRREGULAR GALAXY IC 10

    International Nuclear Information System (INIS)

    Nidever, David L.; Slater, Colin T.; Bell, Eric F.; Ashley, Trisha; Simpson, Caroline E.; Ott, Jürgen; Johnson, Megan; Stanimirović, Snežana; Putman, Mary; Majewski, Steven R.; Jütte, Eva; Oosterloo, Tom A.; Burton, W. Butler

    2013-01-01

    Using deep 21 cm H I data from the Green Bank Telescope we have detected an ≳18.3 kpc long gaseous extension associated with the starbursting dwarf galaxy IC 10. The newly found feature stretches 1.°3 to the northwest and has a large radial velocity gradient reaching to ∼65 km s –1 lower than the IC 10 systemic velocity. A region of higher column density at the end of the extension that possesses a coherent velocity gradient (∼10 km s –1 across ∼26') transverse to the extension suggests rotation and may be a satellite galaxy of IC 10. The H I mass of IC 10 is 9.5 × 10 7 (d/805 kpc) 2 M ☉ and the mass of the new extension is 7.1 × 10 5 (d/805 kpc) 2 M ☉ . An IC 10-M31 orbit using known radial velocity and proper motion values for IC 10 show that the H I extension is inconsistent with the trailing portion of the orbit so that an M31-tidal or ram pressure origin seems unlikely. We argue that the most plausible explanation for the new feature is that it is the result of a recent interaction (and possible late merger) with another dwarf galaxy. This interaction could not only have triggered the origin of the recent starburst in IC 10, but could also explain the existence of previously found counter-rotating H I gas in the periphery of the IC 10 which was interpreted as originating from primordial gas infall

  12. Assessing the organizational context for EBP implementation: the development and validity testing of the Implementation Climate Scale (ICS).

    Science.gov (United States)

    Ehrhart, Mark G; Aarons, Gregory A; Farahnak, Lauren R

    2014-10-23

    Although the importance of the organizational environment for implementing evidence-based practices (EBP) has been widely recognized, there are limited options for measuring implementation climate in public sector health settings. The goal of this research was to develop and test a measure of EBP implementation climate that would both capture a broad range of issues important for effective EBP implementation and be of practical use to researchers and managers seeking to understand and improve the implementation of EBPs. Participants were 630 clinicians working in 128 work groups in 32 US-based mental health agencies. Items to measure climate for EBP implementation were developed based on past literature on implementation climate and other strategic climates and in consultation with experts on the implementation of EBPs in mental health settings. The sample was randomly split at the work group level of analysis; half of the sample was used for exploratory factor analysis (EFA), and the other half was used for confirmatory factor analysis (CFA). The entire sample was utilized for additional analyses assessing the reliability, support for level of aggregation, and construct-based evidence of validity. The EFA resulted in a final factor structure of six dimensions for the Implementation Climate Scale (ICS): 1) focus on EBP, 2) educational support for EBP, 3) recognition for EBP, 4) rewards for EBP, 5) selection for EBP, and 6) selection for openness. This structure was supported in the other half of the sample using CFA. Additional analyses supported the reliability and construct-based evidence of validity for the ICS, as well as the aggregation of the measure to the work group level. The ICS is a very brief (18 item) and pragmatic measure of a strategic climate for EBP implementation. It captures six dimensions of the organizational context that indicate to employees the extent to which their organization prioritizes and values the successful implementation of EBPs

  13. Advanced electromagnetism foundations, theory and applications

    CERN Document Server

    Barrett, Terence W

    1995-01-01

    Advanced Electromagnetism: Foundations, Theory and Applications treats what is conventionally called electromagnetism or Maxwell's theory within the context of gauge theory or Yang-Mills theory. A major theme of this book is that fields are not stand-alone entities but are defined by their boundary conditions. The book has practical relevance to efficient antenna design, the understanding of forces and stresses in high energy pulses, ring laser gyros, high speed computer logic elements, efficient transfer of power, parametric conversion, and many other devices and systems. Conventional electro

  14. Fastbus non-forced air-cooling tests

    International Nuclear Information System (INIS)

    Downing, R.W.

    1981-07-01

    Tests were conducted on a closed box with all walls at room temperature with heat test units positioned between the plates with small cardboard spacers. The rear of the test unit was taped closed, and no external air was allowed to flow through the box. Outside wall temperature was monitored for all tests. Tests were performed to test a possible method of conducting heat away from high powered I.C.'s in a closed chamber. The effect of a brass strip attached to the top of the I.C. and making mechanical contact with the wall of the box is tested. Tests show that some heatsinking technique is needed for I.C.'s of more than 3/4 watt dissipation. It is concluded that conventional air-cooled printed circuit boards can be effectively cooled by simply installing them in a cool-walled box. The chassis construction could also consist of card slots divided by water filled plates similar to refrigeration walls. Problems relating to wire-wrap modules are addressed

  15. First environmental data from the EUV engineering test stand

    Science.gov (United States)

    Klebanoff, Leonard E.; Malinowski, Michael E.; Grunow, Philip A.; Clift, W. Miles; Steinhaus, Chip; Leung, Alvin H.; Haney, Steven J.

    2001-08-01

    The first environmental data from the Engineering Test Stand (ETS) has been collected. Excellent control of high-mass hydrocarbons has been observed. This control is a result of extensive outgas testing of components and materials, vacuum compatible design of the ETS, careful cleaning of parts and pre-baking of cables and sub assemblies where possible, and clean assembly procedures. As a result of the hydrocarbon control, the residual ETS vacuum environment is rich in water vapor. Analysis of witness plate data indicates that the ETS environment does not pose a contamination risk to the optics in the absence of EUV irradiation. However, with EUV exposure, the water rich environment can lead to EUV- induced water oxidation of the Si-terminated Mo/Si optics. Added ethanol can prevent optic oxidation, allowing carbon growth via EUV cracking of low-level residual hydrocarbons to occur. The EUV environmental issues are understood, mitigation approaches have been validated, and EUV optic contamination appears to be manageable.

  16. Fall risk screening in the elderly: A comparison of the minimal chair height standing ability test and 5-repetition sit-to-stand test.

    Science.gov (United States)

    Reider, Nadia; Gaul, Catherine

    2016-01-01

    Successfully identifying older adults with a high risk of falling can be complicated, time consuming and not feasible in daily medical practice. This study compared the effectiveness of the Minimal Chair Height Standing Ability Test (MCHSAT) and 5-repetition sit-to-stand tst (5R-STS) as fall risk-screening instruments for the elderly. 167 community-dwelling older adults (mean age=83.6±7.3years) were interviewed for demographics, fall history, cognition, and mobility status. MCHSAT performance was assessed using a chair whose seat height was modifiable by increments of 5cm, starting at 47cm and lowering after each successful attempt. 5R-STS performance was assessed by recording the time it took to rise and sit back down five consecutive times from a chair of 47cm high. Operating Receiving Characteristic (ROC) curves and Area under the Curve (AUC) were calculated for each test as well as for sub-groups of participants classified based on medical comorbidities (e.g. cardiac disease/stroke, lower limb arthritis). The MCHSAT and 5R-STS were equally effective fall-risk screening instruments for the overall population (AUC (95% CI)=0.72 (0.63-0.82) and 0.73(0.64-0.81) respectively). The 5R-STS was more effective than the MCHSAT for participants suffering from lower limb arthritis (AUC (95% CI)=0.81(0.70-0.92) and 0.71(0.58-0.85) respectively) while the opposite was true for participants with a history of cardiac disease or stroke (AUC (95% CI)=0.59 (0.44-0.80) and 0.65 (0.47-0.84) respectively). Due to their simplicity and quick administration time, the MCHSAT and 5R-STS are equally suitable for implementation in clinical settings. Copyright © 2016. Published by Elsevier Ireland Ltd.

  17. Simulation of a class of hazardous situations in the ICS «INM RAS - Baltic Sea»

    Science.gov (United States)

    Zakharova, Natalia; Agoshkov, Valery; Aseev, Nikita; Parmuzin, Eugene; Sheloput, Tateana; Shutyaev, Victor

    2017-04-01

    Development of Informational Computational Systems (ICS) for data assimilation procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in mathematical modeling, theory of adjoint equations and optimal control, inverse problems, numerical methods theory, numerical algebra, scientific computing and processing of satellite data. In this work the results on the ICS development for PC-ICS "INM RAS - Baltic Sea" are presented. We discuss practical problems studied by ICS. The System includes numerical model of the Baltic Sea thermodynamics, the new oil spill model describing the propagation of a slick at the Sea surface (Agoshkov, Aseev et al., 2014) and the optimal ship route calculating block (Agoshkov, Zayachkovsky et al., 2014). The ICS is based on the INMOM numerical model of the Baltic Sea thermodynamics (Zalesny et al., 2013). It is possible to calculate main hydrodynamic parameters (temperature, salinity, velocities, sea level) using user-friendly interface of the ICS. The System includes data assimilation procedures (Agoshkov, 2003, Parmuzin, Agoshkov, 2012) and one can use the block of variational assimilation of the sea surface temperature in order to obtain main hydrodynamic parameters. Main possibilities of the ICS and several numerical experiments are presented in the work. By the problem of risk control is meant a problem of determination of optimal resources quantity which are necessary for decreasing the risk to some acceptable value. Mass of oil slick is chosen as a function of control. For the realization of the random variable the quadratic "functional of cost" is introduced. It comprises cleaning costs and deviation of damage of oil pollution from its acceptable value. The problem of minimization of this functional is solved based on the methods of optimal control and the theory of adjoint equations. The solution of this problem is

  18. Several foundational and information theoretic implications of Bell’s theorem

    Science.gov (United States)

    Kar, Guruprasad; Banik, Manik

    2016-08-01

    In 1935, Albert Einstein and two colleagues, Boris Podolsky and Nathan Rosen (EPR) developed a thought experiment to demonstrate what they felt was a lack of completeness in quantum mechanics (QM). EPR also postulated the existence of more fundamental theory where physical reality of any system would be completely described by the variables/states of that fundamental theory. This variable is commonly called hidden variable and the theory is called hidden variable theory (HVT). In 1964, John Bell proposed an empirically verifiable criterion to test for the existence of these HVTs. He derived an inequality, which must be satisfied by any theory that fulfill the conditions of locality and reality. He also showed that QM, as it violates this inequality, is incompatible with any local-realistic theory. Later it has been shown that Bell’s inequality (BI) can be derived from different set of assumptions and it also find applications in useful information theoretic protocols. In this review, we will discuss various foundational as well as information theoretic implications of BI. We will also discuss about some restricted nonlocal feature of quantum nonlocality and elaborate the role of Uncertainty principle and Complementarity principle in explaining this feature.

  19. The measurement of Ksub(IC) in single crystal SiC using the indentation method

    International Nuclear Information System (INIS)

    Henshall, J.L.; Brookes, C.A.

    1985-01-01

    The present work has concentrated on investigating the underlying fracture toughness behaviour of SiC single crystals. This material was chosen because of the commercial importance of the various polycrystalline forms of SiC and the relative ready availability of reasonably sized single crystals. This study has examined the feasibility of using the indentation technique to determine Ksub(IC) in SiC single crystals. This requires much more less complex experimentation and also affords the possibility of being able to use this method to study the orientation dependence of Ksub(IC) in a similar manner to that used to investigate anisotropy in indentation hardness behaviour. A single crystal of 6H-SiC was used for all the hardness and conventional Ksub(IC) results reported here. The particular polytype and orientation were determined using the Laue X-ray method. All the measurements were made under ambient conditions. Three-point bend tests, with a 6 mm span on single edge notched beams, SENB, orientated such that the plane of the notch was brace 112-bar0 brace and the crack propagation direction were used for the conventional Ksub(IC) tests. The hardness indentations were all made on one particular SENB test piece after it had been fractured. The results are discussed. (author)

  20. Dicty_cDB: FC-IC0102 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC-IC (Link to library) FC-IC0102 (Link to dictyBase) - - - Contig-U16527-1 FC-IC01...02F (Link to Original site) FC-IC0102F 434 - - - - - - Show FC-IC0102 Library FC-IC (Link to library) Clone ...ID FC-IC0102 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16527-1 Original site URL http://dict... (bits) Value N AB088483 |AB088483.1 Dictyostelium discoideum gene for gamete and mating-type specific prote...oducing significant alignments: (bits) Value AB088483_1( AB088483 |pid:none) Dictyostelium discoideum gmsA g

  1. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board.

    Directory of Open Access Journals (Sweden)

    Go Yamako

    Full Text Available Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20-88 years; male/female ratio, 226/277 without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual's mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland-Altman plot (bias = -3.1 [ms]-1, 95% limit of agreement: -11.0 to 3.9 [ms]-1. The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87. Furthermore, the test-retest reliability is substantial (intraclass correlation coefficient = 0.64. Thus, the proposed STS score will be useful to detect the early deterioration of motor performance.

  2. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board.

    Science.gov (United States)

    Yamako, Go; Chosa, Etsuo; Totoribe, Koji; Fukao, Yuu; Deng, Gang

    2017-01-01

    Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score) and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20-88 years; male/female ratio, 226/277) without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual's mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland-Altman plot (bias = -3.1 [ms]-1, 95% limit of agreement: -11.0 to 3.9 [ms]-1). The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87). Furthermore, the test-retest reliability is substantial (intraclass correlation coefficient = 0.64). Thus, the proposed STS score will be useful to detect the early deterioration of motor performance.

  3. Determining the size and concentration dependence of gold nanoparticles in vitro cytotoxicity (IC50) test using WST-1 assay

    International Nuclear Information System (INIS)

    Rosli, Nur Shafawati binti; Rahman, Azhar Abdul; Aziz, Azlan Abdul; Shamsuddin, Shaharum

    2015-01-01

    Gold nanoparticles (AuNPs) received a great deal of attention for biomedical applications, especially in diagnostic imaging and therapeutics. Even though AuNPs have potential benefits in biomedical applications, the impact of AuNPs on human and environmental health still remains unclear. The use of AuNPs which is a high-atomic-number materials, provide advantages in terms of radiation dose enhancement. However, before this can become a clinical reality, cytotoxicity of the AuNPs has to be carefully evaluated. Cytotoxicity test is a rapid, standardized test that is very sensitive to determine whether the nanoparticles produced are harmful or benign on cellular components. In this work the size and concentration dependence of AuNPs cytotoxicity in breast cancer cell lines (MCF-7) are tested by using WST-1 assay. The sizes of AuNPs tested were 13 nm, 50 nm, and 70 nm. The cells were seeded in the 96-well plate and were treated with different concentrations of AuNPs by serial dilution for each size of AuNPs. The high concentration of AuNPs exhibit lower cell viability compared to low concentration of AuNPs. We quantified the toxicity of AuNPs in MCF-7 cell lines by determining the IC 50 values in WST-1 assays. The IC 50 values (inhibitory concentrations that effected 50% growth inhibition) of 50 nm AuNPs is lower than 13 nm and 70 nm AuNPs. Mean that, 50nm AuNPs are more toxic to the MCF-7 cells compared to smaller and larger sizes AuNPs. The presented results clearly indicate that the cytotoxicity of AuNPs depend not only on the concentration, but also the size of the nanoparticles

  4. Test of four stand growth simulators for the northeastern United States

    Science.gov (United States)

    Thomas M. Schuler; David A. Marquis; Richard L. Ernst; Brian T. Simpson; Brian T. Simpson

    1993-01-01

    Evaluates SILVAH, FIBER, NE-TWIGS, and OAKSIM, simulators commonly used in the northeastern United States, by comparing predicted stand development with actual stand development records for periods ranging from 15 to 50 years. Results varied with stand parameter, forest type, projection length, and geographic area. Except in the spruce-fir forest type where FIBER...

  5. An experimental test of the causes of forest growth decline with stand age.

    Science.gov (United States)

    Michael G. Ryan; Dan Binkley; James H. Fownes; Christian Giardina; Randy S. Senock

    2004-01-01

    The decline in aboveground wood production after canopy closure in even-aged forest stands is a common pattern in forests, but clear evidence for the mechanism causing the decline is lacking. The problem is fundamental to forest biology, commercial forestry (the decline sets the rotation age), and to carbon storage in forests. We tested three hypotheses...

  6. Finite element modeling of a shaking table test to evaluate the dynamic behaviour of a soil-foundation system

    International Nuclear Information System (INIS)

    Abate, G.; Massimino, M. R.; Maugeri, M.

    2008-01-01

    The deep investigation of soil-foundation interaction behaviour during earthquakes represent one of the key-point for a right seismic design of structures, which can really behave well during earthquake, avoiding dangerous boundary conditions, such as weak foundations supporting the superstructures. The paper presents the results of the FEM modeling of a shaking table test involving a concrete shallow foundation resting on a Leighton Buzzard sand deposit. The numerical simulation is performed using a cap-hardening elasto-plastic constitutive model for the soil and specific soil-foundation contacts to allow slipping and up-lifting phenomena. Thanks to the comparison between experimental and numerical results, the power and the limits of the proposed numerical model are focused. Some aspects of the dynamic soil-foundation interaction are also pointed out

  7. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    Science.gov (United States)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  8. Tests for evaluation of pellets as foundation bed material KBP1003 - ASKAR

    International Nuclear Information System (INIS)

    Johnsson, Anna

    2011-12-01

    The reference design for the backfill of deposition tunnels, described in SKB (2010), include bentonite blocks, bentonite pellets and a foundation bed of bentonite pellets or granulate. The tunnel floor needs to be flat and have sufficient bearing capacity to make it possible to stack the backfill blocks according to the reference design. To achieve a flat foundation the tunnel floor will be covered with a bed of pellets or granulate made of bentonite clay. The bed can be either compacted or non compacted. Bed tests have been performed as a part of the project KBP1003 DP1 Design, which is a subproject of KBP1003 ASKAR. The main objectives for KBP1003 DP1 is to define all requirements for the backfill and its production and installation prior to start of the large scale tests, based on given perquisites. KBP1003 is based on the reference design for the backfill of deposition tunnels which was developed in 2010 (SKB 2010). The concept for installation and block design has been further developed during the project. A new dimension of the backfill blocks has been developed; the chosen dimension makes it possible to gain overlapping joints between the blocks by block stacking. The further developed concept is hereinafter referred to as the ASKAR-concept. The purpose of the performed bed tests was to define the bed requirements in the backfill installation to enable stable stacking of backfill blocks. The tests included stacking of blocks on different bed materials, on blasted and wire sawn floor, with and without concurrent water inflow. The bed tests was subdivided into four main parts: - block stacking on different bed compositions - block stacking on bed during water inflow - block stacking in a realistic test tunnel - block stacking on the upper part of the deposition hole and bevel

  9. Tests for evaluation of pellets as foundation bed material KBP1003 - ASKAR

    Energy Technology Data Exchange (ETDEWEB)

    Johnsson, Anna (ES-Konsult AB (Sweden))

    2011-12-15

    The reference design for the backfill of deposition tunnels, described in SKB (2010), include bentonite blocks, bentonite pellets and a foundation bed of bentonite pellets or granulate. The tunnel floor needs to be flat and have sufficient bearing capacity to make it possible to stack the backfill blocks according to the reference design. To achieve a flat foundation the tunnel floor will be covered with a bed of pellets or granulate made of bentonite clay. The bed can be either compacted or non compacted. Bed tests have been performed as a part of the project KBP1003 DP1 Design, which is a subproject of KBP1003 ASKAR. The main objectives for KBP1003 DP1 is to define all requirements for the backfill and its production and installation prior to start of the large scale tests, based on given perquisites. KBP1003 is based on the reference design for the backfill of deposition tunnels which was developed in 2010 (SKB 2010). The concept for installation and block design has been further developed during the project. A new dimension of the backfill blocks has been developed; the chosen dimension makes it possible to gain overlapping joints between the blocks by block stacking. The further developed concept is hereinafter referred to as the ASKAR-concept. The purpose of the performed bed tests was to define the bed requirements in the backfill installation to enable stable stacking of backfill blocks. The tests included stacking of blocks on different bed materials, on blasted and wire sawn floor, with and without concurrent water inflow. The bed tests was subdivided into four main parts: - block stacking on different bed compositions - block stacking on bed during water inflow - block stacking in a realistic test tunnel - block stacking on the upper part of the deposition hole and bevel

  10. Feasibility of automated foundational ontology interchangeability

    CSIR Research Space (South Africa)

    Khan, ZC

    2014-11-01

    Full Text Available the Source Domain Ontology (sOd), with the domain knowledge com- ponent of the source ontology, the Source Foundational Ontology (sOf ) that is the foundational ontology component of the source ontology that is to be interchanged, and any equivalence... or subsumption mappings between enti- ties in sOd and sOf . – The Target Ontology (tO) which has been interchanged, which comprises the Target Domain Ontology (tOd), with the domain knowledge component of the target ontology, and the Target Foundational Ontology...

  11. Effect of posterior tibial tendon dysfunction on unipedal standing balance test.

    Science.gov (United States)

    Kulig, Kornelia; Lee, Szu-Ping; Reischl, Stephen F; Noceti-DeWit, Lisa

    2015-01-01

    Foot pain and diminished functional capacity are characteristics of tibialis posterior tendon dysfunction (TPTD). This study tested the hypotheses that women with TPTD would have impaired performance of a unipedal standing balance test (USBT) and that balance performance would be related to the number of single limb heel raises (SLHR). Thirty-nine middle-aged women, 19 with early stage TPTD (stage I and II), were instructed to perform 2 tasks; a USBT and repeated SLHR. Balance success was defined as a 10-second stance. For those who were successful, center of pressure (COP) data in anterior-posterior (AP) and medial-lateral (ML) directions were recorded as a measure of postural sway. SLHR performance was divided into 3 bins (≤2; 3-9 and > 10 repetitions). The between-balance success on performing the SLHR test was analyzed using the Fisher's exact test (2 × 3). Independent t tests were used to compare between-group differences in postural sway. Relationship of postural sway to the number of heel raises was assessed using Spearman's rho. The success rate of the USBT was significantly lower in women with TPTD than the controls (47% vs 85%, P = .041). In addition, women with TPTD who completed the USBT exhibited increased AP COP displacement (14.0 ± 7.4 vs 8.4 ± 1.3 mm, P = .008), and a strong trend of increased ML COP displacement (8.3 ± 4.5 vs 6.1 ± 1.2 mm, P = .050). The success rate of USBT was correlated with the number of SLHR (P = .01). The AP and ML COP displacement were correlated with SLHR (r = -.538 and .495), respectively. Women with TPTD have difficulty in performing the USBT. Performance of the USBT and SLHR are highly correlated and predictive of each other. A unipedal balance test may be used as a proxy TPTD assessment tool to the heel raising test when pain prevents performance. Level III, case control study. © The Author(s) 2014.

  12. Instrumentation and control system for the AT-2 accelerator test stand

    International Nuclear Information System (INIS)

    Wadlinger, E.A.; Holtkamp, D.B.; Holt, H.D.

    1984-01-01

    A data-driven subroutine package, written for our accelerator test stand (ATS), is described. This flexible package permits the rapid writing and modifying of data acquisition, control, and analysis programs for the many diverse experiments performed on the ATS. These structurally simple and easy to maintain routines help to control administratively the integrity of the ATS through the use of the database. Our operating experience indicates that the original design goals have been met. We describe the subroutines, database, and our experiences with this system

  13. The study of fix composite panel and steel plates on testing stand

    Science.gov (United States)

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  14. Laser based beam diagnostic for the RAL Front End Test Stand (FETS)

    International Nuclear Information System (INIS)

    Gabor, C.; Lee, D. A.; Pozimski, J. K.; Letchford, A.

    2007-01-01

    For the diagnostic of high power particle beams, non-destructive measurement devices provide minimum influence on the beam and avoid various problems in connection with the high power density on surfaces. An H- ion beam offers the opportunity of non destructive beam diagnostics based on the effect of photo detachment. By the interaction of light with H- ions, the additional electron can be detached and a small number of neutrals will be produced. An additional magnetic dipole field can then be used to separate the detached electrons and neutrals from the ions. Using an integral detector the spatial distribution of the beam ion density can be derived, while the use of a spatial resolving detector enables to determine the phase space distribution. To investigate the measurement principle of the latter, a test stand was set up at the IAP in Frankfurt. This system will now be adopted to the requirements of the Front End Test Stand at CCLRC/ RAL. The aim of this FETS is to demonstrate a chopped H- beam of 60mA at 3MeV and 50pps with sufficiently high beam quality. The paper will present a detailed description of the proposed set up at RAL and discuss several results of simulations and experimental data gained in Frankfurt

  15. EQUIVOCATION IN THE FOUNDATIONS OF LEIBNIZ’S INFINITESIMAL FICTIONS

    Directory of Open Access Journals (Sweden)

    Tzuchien THO

    2012-11-01

    Full Text Available In this article, I address two different kinds of equivocations in reading Leibniz’s fictional infinite and infinitesimal. These equivocations form the background of a reductive reading of infinite and infinitesimal fictions either as ultimately finite or as something whose status can be taken together with any other mathematical object as such. The first equivocation is the association of a foundation of infinitesimals with their ontological status. I analyze this equivocation by criticizing the logicist influence on 20th century Anglophone reception of the syncategorematical infinite and infinitesimal. The second equivocation is the association of the rigor of mathematical demonstration with the problem of the admissibility of infinite or infinitesimal terms. I analyze this by looking at Leibniz’s constructive method and apagogic argument style in his quadrature method. In treating these equivocations, I critique some assumptions that underlie the reductive reading of Leibniz’s fictionalism concerning infinite and infinitesimals. In turn, I suggest that these infinitesimal “fictions” pointed to a problematic within Leibniz’s work that was conceived and reconsidered in Leibniz’s work from a range of different contexts and methods.Keywords: Leibniz, differential calculu

  16. Use of reinforced soil foundation (RSF) to support shallow foundation : summary report, November 2008.

    Science.gov (United States)

    2008-05-01

    This research study investigates the potential benefits of using reinforced soil foundations to improve the bearing : capacity and reduce the settlement of shallow foundations on soils. To implement this objective, a total of 117 : tests, including 3...

  17. Use of reinforced soil foundation (RSF) to support shallow foundation : final report, November 2008.

    Science.gov (United States)

    2008-11-01

    This research study aims at investigating the potential benefits of using reinforced soil foundations to improve the bearing capacity and reduce the settlement of shallow foundations on soils. To implement this objective, a total of 117 tests, includ...

  18. Static Behaviour of Bucket Foundations

    DEFF Research Database (Denmark)

    Larsen, Kim André

    One new foundation concept in relation to offshore wind turbines is bucket foundations. The concept is known from the oil and gas industry, though the load conditions here are significantly different. The bucket foundation can be used as monopod or e.g. tripod foundations for offshore wind turbines....... The monopod concept is investigated in this thesis, regarding the static behaviour from loads relevant to offshore wind turbines. The main issue in this concept is the rotational stiffness of the foundation and the combined capacity dominated by moments. The vertical bearing capacity of bucket foundations...... theory is proposed. The proposed expression applies to plane strain as well as axis-symmetric stress conditions for foundations with smooth or rough bases. A thorough experimental investigation of the static behaviour of bucket foundations subjected to combined loading is carried out. Laboratory tests...

  19. Radiation measurements during cavities conditioning on APS RF test stand

    International Nuclear Information System (INIS)

    Grudzien, D.M.; Kustom, R.L.; Moe, H.J.; Song, J.J.

    1993-01-01

    In order to determine the shielding structure around the Advanced Photon Source (APS) synchrotron and storage ring RF stations, the X-ray radiation has been measured in the near field and far field regions of the RF cavities during the normal conditioning process. Two cavity types, a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity, are used on the APS and are conditioned in the RF test stand. Vacuum measurements are also taken on a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity. The data will be compared with data on the five-cell cavities from CERN

  20. FinFET modeling for IC simulation and design

    CERN Document Server

    Hu, Chenming; Lu, Darsen D

    2015-01-01

    This book is the first to explain FinFET modeling for IC simulation and the industry standard - BSIM-CMG - describing the rush in demand for advancing the technology from planar to 3D architecture, as now enabled by the approved industry standard. The book gives a strong foundation on the physics and operation of FinFET, details aspects of the BSIM-CMG model such as surface potential, charge and current calculations, and includes a dedicated chapter on parameter extraction procedures, providing a step-by-step approach for the efficient extraction of model parameters. With this book you will learn: * Why you should use FinFET* The physics and operation of FinFET* Details of the FinFET standard model (BSIM-CMG)* Parameter extraction in BSIM-CMG* FinFET circuit design and simulation * Authored by the lead inventor and developer of FinFET, and developers of the BSIM-CM standard model, providing an experts' insight into the specifications of the standard* The first book on the industry-standard FinFET model - BSIM...

  1. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  2. Fluorescent screens and image processing for the APS linac test stand

    International Nuclear Information System (INIS)

    Berg, W.; Ko, K.

    1992-01-01

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image

  3. Performance studies of the vibration wire monitor on the test stand with low energy electron beam

    International Nuclear Information System (INIS)

    Okabe, Kota; Yoshimoto, Masahiro; Kinsho, Michikazu

    2015-01-01

    In the high intensity proton accelerator as the Japan Proton Accelerator Research Complex (J-PARC) accelerators, serious radiation and residual dose is induced by a small beam loss such a beam halo. Therefore, diagnostics of the beam halo formation is one of the most important issues to control the beam loss. For the beam halo monitor, the vibration wire monitor (VWM) has a potential for investigating the beam halo and weak beam scanning. The VWM has a wide dynamic range, high resolution and the VWM is not susceptible to secondary electrons and electric noises. We have studied the VWM features as a new beam-halo monitor on the test stand with low energy electron gun. The frequency shift of the irradiated vibration wire was confirmed about wire material and the electron beam profile measured by using the VWM was consistent with the results of the Faraday cup measurement. Also we calculated a temperature distribution on the vibration wire which is irradiated by the electron beam with the numerical simulation. The simulations have been fairly successful in reproducing the transient of the irradiated vibration wire frequency measured by test stand experiments. In this paper, we will report a result of performance evaluation for the VWM on the test stands and discuss the VWM for beam halo diagnostic. (author)

  4. Initial results for a 170 GHz high power ITER waveguide component test stand

    Science.gov (United States)

    Bigelow, Timothy; Barker, Alan; Dukes, Carl; Killough, Stephen; Kaufman, Michael; White, John; Bell, Gary; Hanson, Greg; Rasmussen, Dave

    2014-10-01

    A high power microwave test stand is being setup at ORNL to enable prototype testing of 170 GHz cw waveguide components being developed for the ITER ECH system. The ITER ECH system will utilize 63.5 mm diameter evacuated corrugated waveguide and will have 24 >150 m long runs. A 170 GHz 1 MW class gyrotron is being developed by Communications and Power Industries and is nearing completion. A HVDC power supply, water-cooling and control system has been partially tested in preparation for arrival of the gyrotron. The power supply and water-cooling system are being designed to operate for >3600 second pulses to simulate the operating conditions planned for the ITER ECH system. The gyrotron Gaussian beam output has a single mirror for focusing into a 63.5 mm corrugated waveguide in the vertical plane. The output beam and mirror are enclosed in an evacuated duct with absorber for stray radiation. Beam alignment with the waveguide is a critical task so a combination of mirror tilt adjustments and a bellows for offsets will be provided. Analysis of thermal patterns on thin witness plates will provide gyrotron mode purity and waveguide coupling efficiency data. Pre-prototype waveguide components and two dummy loads are available for initial operational testing of the gyrotron. ORNL is managed by UT-Battelle, LLC, for the U.S. Dept. of Energy under Contract DE-AC-05-00OR22725.

  5. Sapflow-Based Stand Transpiration in a Semiarid Natural Oak Forest on China’s Loess Plateau

    Directory of Open Access Journals (Sweden)

    Mei-Jie Yan

    2016-10-01

    Full Text Available The semi-arid region of China’s Loess Plateau is characterized by fragile ecosystems and a shortage of water resources. The major natural forest type in this region is the secondary forest with the flora dominated by the Liaodong oak (Quercus liaotungensis Koidz.. To understand its transpiration water use in relation to environmental factors, we applied Granier-type thermal dissipation probes to monitor stem sap flows of 21 sample trees, representing different classes of diameter at breast height in a permanent plot. The stem- and stand-scale transpiration values during the 2008–2010 growing seasons were estimated using measurements of sap flux densities and corresponding sapwood areas. The dominant factors affecting stand-scale transpiration varied with time scales. Daily stand transpiration correlated with daily solar radiation and daytime average vapor pressure deficit. Seasonal and interannual changes in stand transpiration were closely related to leaf area index (LAI values. No obvious relationship was observed between monthly stand transpiration and soil moisture or precipitation during the period, probably as a result of both the hysteretic effect of precipitation on transpiration, and changes in LAI throughout the growing season. Stand transpiration during the three growing seasons ranged from 75 to 106 mm, representing low to normal values for the semi-arid forest. The proportion of transpiration by oak trees in the stand was stable ranging from 60% to 66% and corresponded to their basal area proportion of approximately 59%. The results suggest that the natural forest consisting mainly of oak trees is in a formal stage of forest development that maintains a normal magnitude of annual water consumption.

  6. Determining the size and concentration dependence of gold nanoparticles in vitro cytotoxicity (IC{sub 50}) test using WST-1 assay

    Energy Technology Data Exchange (ETDEWEB)

    Rosli, Nur Shafawati binti; Rahman, Azhar Abdul [School of Physics, Universiti Sains Malaysia, 11800, Pulau Pinang (Malaysia); Aziz, Azlan Abdul [School of Physics, Universiti Sains Malaysia, 11800, Pulau Pinang (Malaysia); Nano-Biotechnology Research and Innovation (NanoBRI), Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, 11800, Pulau Pinang (Malaysia); Shamsuddin, Shaharum [Nano-Biotechnology Research and Innovation (NanoBRI), Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, 11800, Pulau Pinang (Malaysia); School of Health Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2015-04-24

    Gold nanoparticles (AuNPs) received a great deal of attention for biomedical applications, especially in diagnostic imaging and therapeutics. Even though AuNPs have potential benefits in biomedical applications, the impact of AuNPs on human and environmental health still remains unclear. The use of AuNPs which is a high-atomic-number materials, provide advantages in terms of radiation dose enhancement. However, before this can become a clinical reality, cytotoxicity of the AuNPs has to be carefully evaluated. Cytotoxicity test is a rapid, standardized test that is very sensitive to determine whether the nanoparticles produced are harmful or benign on cellular components. In this work the size and concentration dependence of AuNPs cytotoxicity in breast cancer cell lines (MCF-7) are tested by using WST-1 assay. The sizes of AuNPs tested were 13 nm, 50 nm, and 70 nm. The cells were seeded in the 96-well plate and were treated with different concentrations of AuNPs by serial dilution for each size of AuNPs. The high concentration of AuNPs exhibit lower cell viability compared to low concentration of AuNPs. We quantified the toxicity of AuNPs in MCF-7 cell lines by determining the IC{sub 50} values in WST-1 assays. The IC{sub 50} values (inhibitory concentrations that effected 50% growth inhibition) of 50 nm AuNPs is lower than 13 nm and 70 nm AuNPs. Mean that, 50nm AuNPs are more toxic to the MCF-7 cells compared to smaller and larger sizes AuNPs. The presented results clearly indicate that the cytotoxicity of AuNPs depend not only on the concentration, but also the size of the nanoparticles.

  7. Down force calibration stand test report

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The Down Force Calibration Stand was developed to provide an improved means of calibrating equipment used to apply, display and record Core Sample Truck (CST) down force. Originally, four springs were used in parallel to provide a system of resistance that allowed increasing force over increasing displacement. This spring system, though originally deemed adequate, was eventually found to be unstable laterally. For this reason, it was determined that a new method for resisting down force was needed

  8. LABA/LAMA combinations versus LAMA monotherapy or LABA/ICS in COPD: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Rodrigo GJ

    2017-03-01

    Full Text Available Gustavo J Rodrigo,1 David Price,2,3 Antonio Anzueto,4,5 Dave Singh,6 Pablo Altman,7 Giovanni Bader,8 Francesco Patalano,8 Robert Fogel,7 Konstantinos Kostikas8 1Departamento de Emergencia, Hospital Central de las Fuerzas Armadas, Montevideo, Uruguay; 2Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, Scotland, UK; 3Observational and Pragmatic Research Institute, Singapore; 4University of Texas Health Science Center, 5South Texas Veterans Health Care System, San Antonio, TX, USA; 6Medicines Evaluation Unit, National Institute for Health Research Respiratory and Allergy Clinical Research Facility, University Hospital of South Manchester NHS Foundation Trust, University of Manchester, Manchester, England, UK; 7Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA; 8Novartis Pharma AG, Basel, Switzerland Background: Randomized controlled trials (RCTs indicate that long-acting bronchodilator combinations, such as β2-agonist (LABA/muscarinic antagonist (LAMA, have favorable efficacy compared with commonly used COPD treatments. The objective of this analysis was to compare the efficacy and safety of LABA/LAMA with LAMA or LABA/inhaled corticosteroid (ICS in adults with stable moderate-to-very-severe COPD. Methods: This systematic review and meta-analysis (PubMed/MEDLINE, Embase, Cochrane Library and clinical trial/manufacturer databases included RCTs comparing ≥12 weeks’ LABA/LAMA treatment with LAMA and/or LABA/ICS (approved doses only. Eligible studies were independently selected by two authors using predefined data fields; the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed. Results: Eighteen studies (23 trials were eligible (N=20,185. LABA/LAMA significantly improved trough forced expiratory volume in 1 second (FEV1 from baseline to week 12 versus both LAMA and LABA/ICS (0.07 L and 0.08 L, P<0.0001, with patients more likely to achieve clinically

  9. Few-layer MoS2-anchored graphene aerogel paper for free-standing electrode materials.

    Science.gov (United States)

    Lee, Wee Siang Vincent; Peng, Erwin; Loh, Tamie Ai Jia; Huang, Xiaolei; Xue, Jun Min

    2016-04-21

    To reduce the reliance on polymeric binders, conductive additives, and metallic current collectors during the electrode preparation process, as well as to assess the true performance of lithium ion battery (LIB) anodes, a free-standing electrode has to be meticulously designed. Graphene aerogel is a popular scaffolding material that has been widely used with embedded nanoparticles for application in LIB anodes. However, the current graphene aerogel/nanoparticle composite systems still involve decomposition into powder and the addition of additives during electrode preparation because of the thick aerogel structure. To further enhance the capacity of the system, MoS2 was anchored onto a graphene aerogel paper and the composite was used directly as an LIB anode. The resultant additive-free MoS2/graphene aerogel paper composite exhibited long cyclic performance with 101.1% retention after 700 cycles, which demonstrates the importance of free-standing electrodes in enhancing cyclic stability.

  10. VizieR Online Data Catalog: Optical & Spitzer photometry in IC 1805 (Sung+, 2017)

    Science.gov (United States)

    Sung, H.; Bessell, M. S.; Chun, M.-Y.; Yi, J.; Naze, Y.; Lim, B.; Karimov, R.; Rauw, G.; Park, B.-G.; Hur, H.

    2017-06-01

    For a study of the IMF and the star-formation history of the young open cluster IC 1805, we obtained deep wide-field VRI and Hα images of IC 1805 using the CFH12K mosaic CCD camera of the CFHT on 2002 January 6 and 7. We also observed several regions in IC 1805, for a study of the reddening and massive star content, using the SITe 2000x800 CCD (Maidanak 2k CCD) and standard UBVRI filters of the AZT-22 1.5m telescope at the Maidanak Astronomical Observatory in Uzbekistan on 2003 August 18 and 2004 december 25,30. Later, we obtained additional images of the central region of IC 1805 with the Fairchild 486 CCD (SNUCam) and UBVI and Hα filters of the AZT-22 telescope on 2007 October 7 and 2009 January 19. The Spitzer mapping observations were performed on 2006 September 20 under program ID 20052 (PI: S. Wolff). For complete photometry of stars in the CFH12K FOV in 3.6 and 4.5um, we also downloaded and reduced the GLIMPSE360 data (AOR: 38753280, 38763264, 38769408, 38799104, 38798592, 38784512, PI: B. A. Whitney). MIPS scans of IC 1805 were obtained on 2005 August 31 and 2005 September 2 (PID 3234, PI: J. S. Greeves). The Chandra X-ray Observatory Observations of IC 1805 (ObsID: 7033, PI: L. Townley) were made on 2006 November 25. The total exposure time was about 79ks. The properties of 647 X-ray sources were published in Townsley+ (2014,J/ApJS/213/1). We searched for the optical and MIR counterparts of these X-ray sources with a matching radius of up to 1.5". (4 data files).

  11. Predictive Cutoff Values of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for Disability Incidence in Older People Dwelling in the Community.

    Science.gov (United States)

    Makizako, Hyuma; Shimada, Hiroyuki; Doi, Takehiko; Tsutsumimoto, Kota; Nakakubo, Sho; Hotta, Ryo; Suzuki, Takao

    2017-04-01

    Lower extremity functioning is important for maintaining activity in elderly people. Optimal cutoff points for standard measurements of lower extremity functioning would help identify elderly people who are not disabled but have a high risk of developing disability. The purposes of this study were: (1) to determine the optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability and (2) to examine the impact of poor performance on both tests on the prediction of the risk of disability in elderly people dwelling in the community. This was a prospective cohort study. A population of 4,335 elderly people dwelling in the community (mean age = 71.7 years; 51.6% women) participated in baseline assessments. Participants were monitored for 2 years for the development of disability. During the 2-year follow-up period, 161 participants (3.7%) developed disability. The optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability were greater than or equal to 10 seconds and greater than or equal to 9 seconds, respectively. Participants with poor performance on the Five-Times Sit-to-Stand Test (hazard ratio = 1.88; 95% CI = 1.11-3.20), the Timed "Up & Go" Test (hazard ratio = 2.24; 95% CI = 1.42-3.53), or both tests (hazard ratio = 2.78; 95% CI = 1.78-4.33) at the baseline assessment had a significantly higher risk of developing disability than participants who had better lower extremity functioning. All participants had good initial functioning and participated in assessments on their own. Causes of disability were not assessed. Assessments of lower extremity functioning with the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test, especially poor performance on both tests, were good predictors of future disability in elderly people dwelling in the community. © 2017 American Physical Therapy Association

  12. Conceptualising Intellectual Capital (IC) as Language Game and Power

    DEFF Research Database (Denmark)

    Jørgensen, Kenneth Mølbjerg

    2006-01-01

    Intellectual Capital (IC) can be viewed as knowledge about knowledge, knowledge creation and how such processes might be leveraged into value. Developing a critical understanding of IC requires a historical and contextual understanding of how IC has emerged and how IC is used. This paper, drawing...... this process of social construction. The paper concludes by proposing some methodological guidelines for conducting critical genealogical research on intellectual capital....

  13. A foundation for foundation phase teacher education: Making wise educational judgements

    Directory of Open Access Journals (Sweden)

    Karin Murris

    2014-12-01

    Full Text Available We start our paper with a critical exploration of the current ‘back to basics’ approach in South African foundation phase teacher education with its emphasis on strengthening the teaching of subject knowledge. We claim that such a proposal first demands an answer to the question ‘what is foundational in foundation phase teaching?’ We propose an answer in three stages. First we argue that teacher education should be concerned not only with schooling or qualification (knowledge, skills and dispositions and socialisation, but, drawing on Gert Biesta’s work, also with subjectification (educating the person towards the ability to make wise educational judgements. Secondly, these three aims of education lead to five core principles, and we finish by showing how these principles inform our storied, thinking and multimodal/semiotic curriculum. Our answer to our leading question is that pedagogical ‘know-how’ and views of ‘child’ and ‘childhood’ constitute the subject knowledge that is foundational in the foundation phase curriculum.

  14. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    International Nuclear Information System (INIS)

    2011-01-01

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

  15. High Peak Power Test and Evaluation of S-band Waveguide Switches

    Science.gov (United States)

    Nassiri, A.; Grelick, A.; Kustom, R. L.; White, M.

    1997-05-01

    The injector and source of particles for the Advanced Photon Source is a 2856-MHz S-band electron-positron linear accelerator (linac) which produces electrons with energies up to 650 MeV or positrons with energies up to 450 MeV. To improve the linac rf system availability, an additional modulator-klystron subsystem is being constructed to provide a switchable hot spare unit for each of the five exsisting S-band transmitters. The switching of the transmitters will require the use of SF6-pressurized S-band waveguide switches at a peak operating power of 35 MW. Such rf switches have been successfully operated at other accelerator facilities but at lower peak powers. A test stand has been set up at the Stanford Linear Accelerator Center (SLAC) Klystron Factory to conduct tests comparing the power handling characteristics of two WR-284 and one WR-340 switches. Test results are presented and their implications for the design of the switching system are discussed.

  16. Observation of a H- Beam at the CERN Linac 4 Test Stand using a Pepper-pot

    CERN Document Server

    Delerue, N; Midttun, O; Scrivens, R; Tsesmelis, E

    2010-01-01

    Pepper-pot based transverse emittance measurement has the advantage of providing a fast (single shot) measurement with a relatively simple hardware. We report on the installation of a pepper-pot at the CERN Linac 4 test stand.

  17. A robust free-standing MoS_2/poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) film for supercapacitor applications

    International Nuclear Information System (INIS)

    Ge, Yu; Jalili, Rouhollah; Wang, Caiyun; Zheng, Tian; Chao, Yunfeng; Wallace, Gordon G.

    2017-01-01

    Graphical abstract: MoS_2/PEDOT:PSS hybrid film with high robustness and flexibility demonstrated an excellent capacitive performance in the form of an all-solid-state supercapacitor. - Highlights: • A robust free-standing MoS_2/PEDOT:PSS film has been prepared via a simple vacuum filtration method. • MoS_2/PEDOT hybrid film displays remarkably improved mechanical robustness and flexibility. • MoS_2/PEDOT electrode exhibits high volumetric capacitance and good cycling stability in aqueous electrolyte. • Flexible MoS_2/PEDOT electrode can retain its capacitive performance over 1000 bending cycles in an all-solid-state supercapacitor. - Abstract: Two-dimensional molybdenum disulfide (MoS_2) is a promising energy storage material due to its high surface area and unique electronic structure. Free-standing flexible MoS_2-based electrode is of importance for use in flexible energy storage devices, whereas there are limited reports available. In this work we developed a robust hybrid film, MoS_2 incorporated with highly conductive poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). This free-standing film possesses excellent mechanical properties with a fracture strength of 18.0 MPa and a Young’s modulus of 2.0 GPa. It can deliver a large volumetric capacitance of 141.4 F cm"−"3, a high volumetric energy density of 4.9 mWh cm"−"3, and a capacitance retention rate of 98.6% after 5000 charge/discharge cycles. This film has demonstrated its application in an all-solid-state bendable supercapacitor as well.

  18. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Forced vibration tests of a model foundation on rock ground

    International Nuclear Information System (INIS)

    Kisaki, N.; Siota, M.; Yamada, M.; Ikeda, A.; Tsuchiya, H.; Kitazawa, K.; Kuwabara, Y.; Ogiwara, Y.

    1983-01-01

    The response of very stiff structures, such as nuclear reactor buildings, to earthquake ground motion is significantly affected by radiation damping due to the soil-structure interaction. The radiation damping can be computed by vibration admittance theory or dynamical ground compliance theory. In order to apply the values derived from these theories to the practical problems, comparative studies between theoretical results and experimental results concerning the soil-structure interaction, especially if the ground is rock, are urgently needed. However, experimental results for rock are less easily obtained than theoretical ones. The purpose of this paper is to describe the harmonic excitation tests of a model foundation on rock and to describe the results of comparative studies. (orig./HP)

  20. Cryogenic infrastructure for Fermilab's ILC vertical cavity test facility

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Ginsburg, C.; Huang, Y.; Norris, B.; Ozelis, J.; Peterson, T.; Poloubotko, V.; Rabehl, R.; Sylvester, C.; Wong, M.; /Fermilab

    2006-06-01

    Fermilab is building a Vertical Cavity Test Facility (VCTF) to provide for R&D and pre-production testing of bare 9-cell, 1.3-GHz superconducting RF (SRF) cavities for the International Linear Collider (ILC) program. This facility is located in the existing Industrial Building 1 (IB1) where the Magnet Test Facility (MTF) also resides. Helium and nitrogen cryogenics are shared between the VCTF and MTF including the existing 1500-W at 4.5-K helium refrigerator with vacuum pumping for super-fluid operation (125-W capacity at 2-K). The VCTF is being constructed in multiple phases. The first phase is scheduled for completion in mid 2007, and includes modifications to the IB1 cryogenic infrastructure to allow helium cooling to be directed to either the VCTF or MTF as scheduling demands require. At this stage, the VCTF consists of one Vertical Test Stand (VTS) cryostat for the testing of one cavity in a 2-K helium bath. Planning is underway to provide a total of three Vertical Test Stands at VCTF, each capable of accommodating two cavities. Cryogenic infrastructure improvements necessary to support these additional VCTF test stands include a dedicated ambient temperature vacuum pump, a new helium purification skid, and the addition of helium gas storage. This paper describes the system design and initial cryogenic operation results for the first VCTF phase, and outlines future cryogenic infrastructure upgrade plans for expanding to three Vertical Test Stands.

  1. The 1-min sit-to-stand test--A simple functional capacity test in cystic fibrosis?

    Science.gov (United States)

    Radtke, Thomas; Puhan, Milo A; Hebestreit, Helge; Kriemler, Susi

    2016-03-01

    We aimed to assess the measurement properties and the minimal important difference (MID) of the 1-min sit-to-stand (STS) test in cystic fibrosis (CF). Patients with CF were tested during a pulmonary rehabilitation program. Five STS tests were performed during the program; two tests at the beginning (STS0 and STS1) and three tests at the end (STS2a-2c). Exercise capacity, pulmonary function, and health-related quality of life (HRQoL) and patient-reported health status were measured at the beginning and end of the program. We calculated overall mean, standard deviation, coefficient of variation (CV), and intraclass correlation coefficient (ICC) of the STS test. The MID was calculated using anchor-based and distributional methods. Fourteen participants (8 female, mean age 30.4±6.1years) were included. STS test performance increased significantly from STS0 to STS1 indicative of a learning effect. Test-retest reliability for the subsequent STS2a-2c tests was excellent (ICC 0.98, 95% CI 0.96-0.99). The estimated MID for the STS test was 5 repetitions. STS test performance was responsive to change (effect size of 0.97) and correlated with exercise capacity (r=0.63-0.73) and with the physical functioning HRQoL scale (r=0.72). The 1-min STS test appears to be a reliable, valid, and feasible test to measure functional capacity in patients with CF. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  2. S-band 45 MW peak power test facility at RRCAT

    International Nuclear Information System (INIS)

    Wanmode, A. Yashwant; Reddy, Sivananda; Mulchandani, J.; Mohania, Praveen; Shrivastava, B. Purushottam

    2015-01-01

    RRCAT is engaged in the design and development of high energy electron LINAC as future injectors for the Booster Synchrotron for Indus-1 and Indus-2 SRS. The high energy LINAC will need microwave power over 30 MW depending on the number of structures to be energized. In order to have advance preparations for this development a 45 MW S-Band test facility has been designed and developed at RRCAT. The test stand is built around a 45 MW peak power S-band pulsed klystron, A conventional pulse forming network based modulator for klystron has been designed and developed. The WR-284 waveguide transmission system consisting of dual directional couplers, SF 6 gas pressurization unit, high power waveguide load and arc sensor has been developed and interfaced with the klystron. The klystron has been successfully tested up to 30 MW peak power at 2856 MHz on SF 6 pressurized waveguide line. A solid state S Band driver amplifier up to 1 kW output power was designed developed for driving the klystron. This paper describes the results of 30 MW peak power test of this facility. (author)

  3. Using a stand-level model to predict light absorption in stands with vertically and horizontally heterogeneous canopies

    Directory of Open Access Journals (Sweden)

    David I Forrester

    2014-09-01

    Full Text Available Background Forest ecosystem functioning is strongly influenced by the absorption of photosynthetically active radiation (APAR, and therefore, accurate predictions of APAR are critical for many process-based forest growth models. The Lambert-Beer law can be applied to estimate APAR for simple homogeneous canopies composed of one layer, one species, and no canopy gaps. However, the vertical and horizontal structure of forest canopies is rarely homogeneous. Detailed tree-level models can account for this heterogeneity but these often have high input and computational demands and work on finer temporal and spatial resolutions than required by stand-level growth models. The aim of this study was to test a stand-level light absorption model that can estimate APAR by individual species in mixed-species and multi-layered stands with any degree of canopy openness including open-grown trees to closed canopies. Methods The stand-level model was compared with a detailed tree-level model that has already been tested in mixed-species stands using empirical data. Both models were parameterised for five different forests, including a wide range of species compositions, species proportions, stand densities, crown architectures and canopy structures. Results The stand-level model performed well in all stands except in the stand where extinction coefficients were unusually variable and it appears unlikely that APAR could be predicted in such stands using (tree- or stand-level models that do not allow individuals of a given species to have different extinction coefficients, leaf-area density or analogous parameters. Conclusion This model is parameterised with species-specific information about extinction coefficients and mean crown length, diameter, height and leaf area. It could be used to examine light dynamics in complex canopies and in stand-level growth models.

  4. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  5. A study on seismic behavior of pile foundations of bridge abutment on liquefiable ground through shaking table tests

    Science.gov (United States)

    Nakata, Mitsuhiko; Tanimoto, Shunsuke; Ishida, Shuichi; Ohsumi, Michio; Hoshikuma, Jun-ichi

    2017-10-01

    There is risk of bridge foundations to be damaged by liquefaction-induced lateral spreading of ground. Once bridge foundations have been damaged, it takes a lot of time for restoration. Therefore, it is important to assess the seismic behavior of the foundations on liquefiable ground appropriately. In this study, shaking table tests of models on a scale of 1/10 were conducted at the large scale shaking table in Public Works Research Institute, Japan, to investigate the seismic behavior of pile-supported bridge abutment on liquefiable ground. The shaking table tests were conducted for three types of model. Two are models of existing bridge which was built without design for liquefaction and the other is a model of bridge which was designed based on the current Japanese design specifications for highway bridges. As a result, the bending strains of piles of the abutment which were designed based on the current design specifications were less than those of the existing bridge.

  6. JAERI Fuel Cleanup System (J-FCU) stand-alone tritium test at the TSTA

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Hayashi, Takumi; Inoue, Masahiko

    1993-03-01

    JAERI designed, fabricated, and installed the JAERI Fuel Cleanup System (J-FCU) as a subsystem of simulated fusion fuel loop at the TSTA. The main function of the J-FCU is to purify and to recover hydrogen isotopes from simulated plasma exhaust while exhausting tritium free impurities. After a lot of deuterium tests, a first tritium test of the J-FCU was performed with one gram of tritium at the TSTA on June 1991. Main purpose of this test was to evaluate the total integrity and function of the J-FCU system with a DT mixture. Through this test, the J-FCU was operated well and its function with tritium was demonstrated. This report describes the detail test results of the J-FCU first tritium test and discuss its functions by stand-alone mode. Residual tritium inventory of the J-FCU system was also discussed. (author)

  7. F-15B ACTIVE with thrust vectoring nozzles on test stand

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the thrust stand being used for ground testing of a new thrust-vectoring concept involving two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could lead to significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace.

  8. Beam-Based Diagnostics of RF-Breakdown in the Two-Beam Test-Stand in CTF3

    CERN Document Server

    Johnson, M

    2007-01-01

    The general outline of a beam-based diagnostic method of RF-breakdown, using BPMs, at the two-beam test-stand in CTF3 is discussed. The basic components of the set-up and their functions in the diagnostic are described. Estimations of the expected error in the measured parameters are performed.

  9. The Design and Construction Process of a Test Stand for Casting the Power Steering’S Housing with the Use of the Pdcpd Material

    Science.gov (United States)

    Sobek, M.; Baier, A.; Grabowski, Ł.

    2018-01-01

    The use of new technologies and materials in various industries is a natural process that is directly related to the very high rate of development of these technologies. Certain industries decide to much faster introduce new technologies and materials. One of such branches is the automotive industry, whose representatives are very energetically looking for both financial savings and savings resulting from the vehicles mass reduction. An economically justified approach to construction materials is leading the search for new solutions and materials. The use of a modern material such as the two-component PDCPD composite shows hitherto unknown possibilities of producing subassemblies of many different constructions. The possibility of using a modern composite material with parameters comparable to that of metals and significantly lighter, can be an excellent alternative in the selection of materials for many parts of motor vehicles. The potentiality of precise casting of tolerated surfaces will allow to reduce the operations related to machining process, which is an indispensable part of the production process of elements that are cast of metal. This article describes the process of designing and building a test stand for precise positioning of power steering gear components at the stage of casting their housing. The article presents the principle of operation of the test stand and the process of preparation for the casting and the cast itself will be rudely described. Due to the implementation of research as part of a research project with an industrial partner, the article will only describe some operations. This is related to the confidentiality of the project.

  10. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  11. Stand and within-stand factors influencing Golden-winged Warbler use of regenerating stands in the central Appalachian Mountains

    Directory of Open Access Journals (Sweden)

    Marja H. Bakermans

    2015-06-01

    Full Text Available The Golden-winged Warbler (Vermivora chrysoptera is currently being considered for protected status under the U.S. Endangered Species Act. The creation of breeding habitat in the Appalachian Mountains is considered a conservation priority for this songbird, which is dependent on extensively forested landscapes with adequate availability of young forest. We modeled abundance of Golden-winged Warbler males in regenerating harvested forest stands that were 0-17 years postharvest at both mid-Appalachian and northeast Pennsylvania regional scales using stand and within-stand characteristics of 222 regenerating stands, 2010-2011. Variables that were most influential at the mid-Appalachian scale were different than those in the northeast region. Across the mid-Appalachian ecoregion, the proportion of young forest cover, i.e., shrub/scrub cover, within 1 km of regenerating stands best explained abundance of Golden-winged Warblers. Golden-winged Warbler response was best explained by a concave quadratic relationship in which abundance was highest with 5-15% land in young forest cover. We also found evidence that the amount of herbaceous cover, i.e., the amount of grasses and forbs, within a regenerating stand positively influenced abundance of Golden-winged Warblers. In northeastern Pennsylvania, where young forest cover is found in high proportions, the distance to the nearest regenerating stand best explained variation in abundance of Golden-winged Warblers. Abundance of Golden-winged Warblers was 1500 m away. When modeling within-stand features in the northeast region, many of the models were closely ranked, indicating that multiple variables likely explained Golden-winged Warbler response to within-stand conditions. Based on our findings, we have proposed several management guidelines for land managers interested in creating breeding habitat for Golden-winged Warblers using commercial timber operations. For example, we recommend when managing for

  12. Extracción de cobre desde soluciones clorhídricas con LIX 860N-IC y LIX 84-IC

    Directory of Open Access Journals (Sweden)

    Navarro, Carlos María

    2001-08-01

    Full Text Available In this work, the extraction of copper from chloride solutions with two hydroxyoximes: 5- nonylsalicylaldoxime (LIX 860N-IC and 2-hydroxy-5-nonylacetophenona oxime (LIX 84-IC is discussed. The results showed that an increase in the acidity and an increase in the total concentration of chloride ions in the aqueous phase decreased significantly the extraction of copper as well as the extraction of iron for both extractants. This effect of the chloride ions can be explained by the formation of a series of chloro complexes of Cu(II and Fe(III in the aqueous phase. The effect of initial pH and total chloride concentration on the extraction of chloride by the organic phase suggests that LIX 860N-IC, and to a lesser extent LIX 84-IC, extract small amounts of the cationic complex, CuCl+. An increase in the concentration of chloride ions also produced a small decrease in the rate of copper extraction with both hydroxyoximes.

    En este trabajo se discute el estudio de la extracción de cobre desde soluciones clorhídricas con dos hidroxioximas: 5-nonilsalicilaldoxima (LIX 860N-IC, y 2-hidroxi-5 nonilacetofenona oxima (LIX 84-IC. Los resultados indicaron que al aumentar la acidez o aumentar la concentración de cloruro en la fase acuosa se produce una significativa disminución en la extracción de cobre y hierro con ambas hidroxioximas. Este efecto del ion cloruro se explica por la formación de varios clorocomplejos de Cu(II y Fe(III en la solución acuosa. El efecto del pH y la concentración total de cloruro en la extracción de cloruro sugiere que el LIX 860N-IC, y en menor grado el LIX 84-IC extraen pequeñas cantidades del catión monovalente, CuCl+. Se determinó también que un aumento en la concentración de cloruro en la solución acuosa produce una leve disminución en la velocidad de extracción del cobre con ambas hidroxioximas.

  13. Number of test trials needed for performance stability and interrater reliability of the one leg stand test in patients with a major non-traumatic lower limb amputation

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Nielsen, Anni Østergaard; Madsen Topp, Ulla

    2014-01-01

    Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST in patie......Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST...... in patients with a major non-traumatic lower limb amputation, and (3) to provide a test procedure....

  14. A remotely-controlled locomotive IC driven by electrolytic bubbles and wireless powering.

    Science.gov (United States)

    Hsieh, Jian-Yu; Kuo, Po-Hung; Huang, Yi-Chun; Huang, Yu-Jie; Tsai, Rong-Da; Wang, Tao; Chiu, Hung-Wei; Wang, Yao-Hung; Lu, Shey-Shi

    2014-12-01

    A batteryless remotely-controlled locomotive IC utilizing electrolytic bubbles as propelling force is realized in 0.35 μm CMOS technology. Without any external components, such as magnets and on-board coils, the bare IC is wirelessly powered and controlled by a 10 MHz ASK modulated signal with RS232 control commands to execute movement in four moving directions and with two speeds. The receiving coil and electrolysis electrodes are all integrated on the locomotive chip. The experiment successfully demonstrated that the bare IC moved on the surface of an electrolyte with a speed up to 0.3 mm/s and change moving directions according to the commands. The total power consumptions of the chip are 207.4 μW and 180 μ W while the output electrolysis voltages are 2 V and 1.3 V, respectively.

  15. The influence of CdS intermediate layer on CdSe/CdS co-sensitized free-standing TiO2 nanotube solar cells

    Science.gov (United States)

    Ren, Xuefeng; Yu, Libo; Li, Zhen; Song, Hai; Wang, Qingyun

    2018-01-01

    We build CdSe quantum dots (QDs) sensitized TiO2 NT solar cells (CdSe/TiO2 solar cells) by successive ionic layer adsorption reaction (SILAR) method on free-standing translucent TiO2 nanotube (NT) film. The best power conversion efficiency (PCE) 0.74% is obtained with CdSe/TiO2 NT solar cells, however, it is very low. Hence, we introduced the CdS QDs layer located between CdSe QDs and TiO2 NT to achieve an enhanced photovoltaic performance. The J-V test results indicated that the insert of CdS intermediate layer yield a significant improvement of PCE to 2.52%. Combining experimental and theoretical analysis, we find that the effects caused by a translucent TiO2 nanotube film, a better lattices match between CdS and TiO2, and a new formed stepwise band edges structure not only improve the light harvesting efficiency but also increase the driving force of electrons, leading to the improvement of photovoltaic performance.

  16. Exploring physical and chemical factors influencing the properties of recombinant prion protein and the real-time quaking-induced conversion (RT-QuIC) assay.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David

    2014-01-01

    Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.

  17. First Stage Acceptance Test

    Science.gov (United States)

    1960-01-01

    This photograph shows the intense smoke and fire created by the five F-1 engines from a test firing of the Saturn V first stage (S-1C) in the S-1C test stand at the Marshall Space Flight Center. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  18. Validity and Responsiveness to Change of the 30-Second Chair-Stand Test in Older Adults Admitted to an Emergency Department

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Mogensen, Christian B; Nørgaard, Birgitte

    2017-01-01

    BACKGROUND AND PURPOSE: Few physical performance measurement tools are validated for acutely admitted older adults, and for this reason we aimed to examine the validity and responsiveness to change of the 30-second Chair-Stand Test (30s-CST) used to assess physical performance in older adults...... in bathing, dressing, cooking, cleaning, and shopping. Concurrent validity of the 30s-CST compared with the de Morton Mobility Index (DEMMI) on physical performance of acutely admitted older adults was examined with 156 patients. The analysis of concurrent validity included the entire DEMMI and 2 subsets...... of DEMMI: "DEMMI walking" and "DEMMI dynamic balance." The responsiveness to change in the 30s-CST compared with DEMMI was examined with 117 patients. All patients were classified as having either low physical performance (30s-CST ≤8) or high physical performance (30s-CST >8); these groups were used...

  19. Three dimensional periodic foundations for base seismic isolation

    International Nuclear Information System (INIS)

    Yan, Y; Mo, Y L; Cheng, Z; Shi, Z; Menq, F; Tang, Y

    2015-01-01

    Based on the concept of phononic crystals, periodic foundations made of periodic materials are investigated in this paper. The periodic foundations can provide low frequency band gaps, which cover the main frequency ranges of seismic waves. Therefore, the periodic foundations are able to protect the upper structures during earthquake events. In this paper, the basic theory of three dimensional periodic foundations is studied and the finite element method was used to conduct the sensitivity study. A simplified three-dimensional periodic foundation with a superstructure was tested in the field and the feasibility of three dimensional periodic foundations was proved. The test results showed that the response of the upper structure with the three dimensional periodic foundation was reduced under excitation waves with the main frequency falling in the attenuation zones. The finite element analysis results are consistent with the experimental data, indicating that three dimensional periodic foundations are a feasible way of reducing seismic vibrations. (paper)

  20. Experimental study on embedment effect of foundation, 2

    International Nuclear Information System (INIS)

    Ohtomo, Keizo; Toma, Junichi; Hashimoto, Koichi; Hanada, Kazutake; Ueshima, Teruyuki; Yajima, Hiroshi

    1986-01-01

    In order to make clear the dynamic behavior of a embeded foundation on the quarternary ground experimentally, a series of forced vibration tests and seismic observation on both the small foundation (4 x 4 x 3 m) and the embeded form larger scale foundation of the shaking table (16 x 16 x 7.7 m) were conducted at the same site. The purposes this study are evaluating the dynamic behavior and the characteristics of dynamic stiffness and damping of the larger foundation based on forced vibration tests, and applying them to the dynamic response analysis of variable embedded foundations. In this report, the authors first examine frequency dependent property and its theoretical tendency of dynamic stiffness and damping surrounding table foundation. And then, consider an applicability and point of discussion related with the some theories which influence the embedment effect, in contrast with the experimental datum of the model foundation are past studies on a embedment effect (JPDR, Large-Scale Foundation in Tadotsu). (author)

  1. Saturn V Second Stage (S-II) Ready for Static Test

    Science.gov (United States)

    1965-01-01

    Two workers are dwarfed by the five J-2 engines of the Saturn V second stage (S-II) as they make final inspections prior to a static test firing by North American Space Division. These five hydrogen -fueled engines produced one million pounds of thrust, and placed the Apollo spacecraft into earth orbit before departing for the moon. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  2. CONDUCTING AND ANALYZING THE RESULTS OF THE EXPERIMENTAL BOX TEST OF RETAINING WALL MODELS WITHOUT PILES AND ON THE PILE FOUNDATION

    Directory of Open Access Journals (Sweden)

    M. A. Lisnevskyi

    2015-08-01

    Full Text Available Purpose. Taking into consideration that the bearing capacity of the foundation may be insufficient, in the study it is assumed that pile foundation can be used to reduce the impact of the construction of new retaining structures on roads and railways near the existing buildings or in areas of dense urban development and ensure the stability of the foundation. To reduce the volume of excavation it is necessary to choose the economic structure of the retaining wall. To do this, one should explore stress-strain state (SSS of the retaining walls, to develop methods to improve their strength and stability, as well as to choose the most appropriate method of their analysis. Methodology. In the design of retaining walls foundation mat and piles are considered as independent elements. Since the combined effect of the retaining wall, piles and foundation mat as well as the effect of soil or rock foundation on the structure are considered not fully, so there are some limitations in the existing design techniques. To achieve the purpose the box tests of retaining walls models without piles and with piles for studying their interaction with the surrounding soil massif were conducted. Findings. Laboratory simulation of complex systems «surrounding soil – retaining wall – pile» was carried out and on the basis of the box test results were analyzed strains and its main parameters of the stress-strain state. Analysis of the results showed that the structure of a retaining wall with piles is steady and stable. Originality. So far, in Ukraine has not been carried out similar experimental box tests with models of retaining walls in such combinations. In the article has been presented unique photos and test results, as well as their analysis. Practical value. Using the methodology of experimental tests of the retaining wall models with piles and without them gives a wider opportunity to study stress-strain state of such structures.

  3. A GRB and Broad-lined Type Ic Supernova from a Single Central Engine

    Science.gov (United States)

    Barnes, Jennifer; Duffell, Paul C.; Liu, Yuqian; Modjaz, Maryam; Bianco, Federica B.; Kasen, Daniel; MacFadyen, Andrew I.

    2018-06-01

    Unusually high velocities (≳0.1c) and correspondingly high kinetic energies have been observed in a subset of Type Ic supernovae (so-called “broad-lined Ic” supernovae; SNe Ic-BL), prompting a search for a central engine model capable of generating such energetic explosions. A clue to the explosion mechanism may lie in the fact that all supernovae that accompany long-duration gamma-ray bursts (GRBs) belong to the SN Ic-BL class. Using a combination of two-dimensional relativistic hydrodynamics and radiation transport calculations, we demonstrate that the central engine responsible for long GRBs can also trigger an SN Ic-BL. We find that a reasonable GRB engine injected into a stripped Wolf–Rayet progenitor produces a relativistic jet with energy ∼1051 erg, as well as an SN whose synthetic light curves and spectra are fully consistent with observed SNe Ic-BL during the photospheric phase. As a result of the jet’s asymmetric energy injection, the SN spectra and light curves depend on viewing angle. The impact of viewing angle on the spectrum is particularly pronounced at early times, while the viewing-angle dependence for the light curves (∼10% variation in bolometric luminosity) persists throughout the photospheric phase.

  4. 3D Integration of MEMS and IC: Design, technology and simulations

    OpenAIRE

    Schjølberg-Henriksen, Kari

    2009-01-01

    * 3D integration: Opportunities and trends* e-CUBES: Tire pressure monitoring system (TPMS)* Package design including thermo-mechanical modeling* Technology development* Sensor packaging concept* Gold stud bump bonding* Device characterization and testing* Summary and outlook 3D Integration of MEMS and IC: Design, technology and simulations

  5. Evaluation of Dynamic Behavior of Pile Foundations for Interim Storage Facilities Through Geotechnical Centrifuge Tests

    International Nuclear Information System (INIS)

    Shizuo Tsurumaki; Hiroyuki Watanabe; Akira Tateishi; Kenichi Horikoshi; Shunichi Suzuki

    2002-01-01

    In Japan, there is a possibility that interim storage facilities for recycled nuclear fuel resources may be constructed on quaternary layers, rather than on hard rock. In such a case, the storage facilities need to be supported by pile foundations or spread foundations to meet the required safety level. The authors have conducted a series of experimental studies on the dynamic behavior of storage facilities supported by pile foundations. A centrifuge modeling technique was used to satisfy the required similitude between the reduced size model and the prototype. The centrifuge allows a high confining stress level equivalent to prototype deep soils to be generated (which is considered necessary for examining complex pile-soil interactions) as the soil strength and the deformation are highly dependent on the confining stress. The soil conditions were set at as experimental variables, and the results are compared. Since 2000, the Nuclear Power Engineering Corporation (NUPEC) has been conducting these research tests under the auspices on the Ministry of Economy, Trade and Industry of Japan. (authors)

  6. Desain dan Implementasi Virtual Laboratory Materi Osilator Analog berbasis IC OP-AMP

    Directory of Open Access Journals (Sweden)

    SYIFAUL FUADA

    2016-08-01

    Full Text Available ABSTRAK Laboratorium virtual merupakan salah satu platform laboratorium modern yang dapat mendukung kegiatan praktikum yang berjalan secara tradisional (Hand-on Laboratory.Penelitian ini bertujuan untuk mendesain dan mengimplementasikan Virtual Laboratory pada materi pembangkit sinyal dengan subtopik: Wien Bridge sebagai osilator RC, Hartley dan Colpitts sebagai osilator LC dan Astable Multivibrator sebagai osilator relaksasi,yang dibangun berbasis IC Operational Amplifier (OP-AMP.Jenis penelitian ini merupakan R&Dyang terdiri dari enam tahapan, yaitu:konsep, desain, pengumpulan bahan, pembuatan, pengujian dan pendistribusian. Aplikasi perangkat lunak berbasis dekstop ini telah diuji secara fungsional dengan 6 (enam aspek parameter yakni:uji polaritas kapastor; uji wiring; uji mode frekuensi dan mode perioda pada alat ukur frequency generator; uji specific decission pada trainer kit osilator hartley dan colpitts; uji kesesuaian antara frekuensi ouput dari masing-masing osilator dengan perhitungan teorema dan hasil percobaan sesungguhnya; dan uji kualitas media. Hasil secara keseluruhan telah sesuai dengan ekspektasi didalam story board. Kata kunci: IC OP-AMP, Osilator analog, Laboratorium virtual ABSTRACT The Virtual Laboratory is as one of modern laboratory platform which able to supportthe hand-on worklab. The goal of this research are for designing and implementing a Virtual Laboratory of signal generator material with subtopics i.e. the Wien Bridge as an RC oscillator, the Hartley and Colpitts as LC oscillator and the astable multivibrator as relaxation oscillator which assembled based on Operational Amplifier Integrated Circuit (OP-AMP.This research is R&D type which consists of six stages, i.e. concept, design, materials collection, assembling, testing and distribution. This desktop-based software application has been functionally tested with six aspect of parameters such as: capacitor polarity testing; wiring testing; testing of frequency

  7. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Wearable Sensor Use for Assessing Standing Balance and Walking Stability in People with Parkinson’s Disease: A Systematic Review

    Science.gov (United States)

    Hubble, Ryan P.; Naughton, Geraldine A.; Silburn, Peter A.; Cole, Michael H.

    2015-01-01

    Background Postural instability and gait disability threaten the independence and well-being of people with Parkinson’s disease and increase the risk of falls and fall-related injuries. Prospective research has shown that commonly-used clinical assessments of balance and walking lack the sensitivity to accurately and consistently identify those people with Parkinson’s disease who are at a higher risk of falling. Wearable sensors provide a portable and affordable alternative for researchers and clinicians who are seeking to objectively assess movements and falls risk in the clinical setting. However, no consensus currently exists on the optimal placements for sensors and the best outcome measures to use for assessing standing balance and walking stability in Parkinson’s disease patients. Hence, this systematic review aimed to examine the available literature to establish the best sensor types, locations and outcomes to assess standing balance and walking stability in this population. Methods Papers listed in three electronic databases were searched by title and abstract to identify articles measuring standing balance or walking stability with any kind of wearable sensor among adults diagnosed with PD. To be eligible for inclusion, papers were required to be full-text articles published in English between January 1994 and December 2014 that assessed measures of standing balance or walking stability with wearable sensors in people with PD. Articles were excluded if they; i) did not use any form of wearable sensor to measure variables associated with standing balance or walking stability; ii) did not include a control group or control condition; iii) were an abstract and/or included in the proceedings of a conference; or iv) were a review article or case study. The targeted search of the three electronic databases identified 340 articles that were potentially eligible for inclusion, but following title, abstract and full-text review only 26 articles were deemed

  9. Geotechnical zoning of urban foundations: Avilés case study (N Spain)

    Science.gov (United States)

    María Díaz-Díaz, Luis; Arias, Daniel; López-Fernández, Carlos; Pando, Luis

    2014-05-01

    The purpose of this paper is to carry out a geotechnical evaluation of the underground within an urban setting in relation to types of foundations, and particularly at expansion zones. The ultimate aim is to produce a foundation zonation map at the scale 1:10,000. Furthermore, a general methodology that way be extrapolated to other cities is proposed. This work focused on the city of Aviles like a case study; a medium-sized city which has significant industrial and port areas and singular equipment in its surroundings. This city is located in the Spanish north coast and spread out on both flanks of the Avilés stuary. This means that there are an important development of recent deposits that implies different geotechnical units with a highly variable behavior, generally poor. In contrast, the bedrock is more homogenous, formed by Permo-Triassic red clay and marl. Locally there are also outcrops of carbonates and conglomeratic Jurassic levels. Also, on the whole area is important to note the presence of heterogeneous anthropic deposits along the whole area as a consequence, mainly, of an intense industrial activity. Permo-Triassic clayey and marly materials imply special engineering issues in foundations as a consequence of their composition (likely weathering, presence of gypsum, low bearing capacity). Moreover, recent deposits (marine and alluvial origin) show different geotechnical behaviors depending on their geometry and grain size. Hence, many areas of the city are especially problematic when designing and implementing foundations. The methodology followed in this study consisted in elaborating a geological-geotechnical exhaustive survey of the urban underground on a scale of 1/10.000. Based on this, a multi criteria analysis of the identified geotechnical units was carried out taking into consideration all the lithological, geomorphological, hidrogeological and geotechnical aspects. Taken into account all of these criteria, a number of areas are defined based

  10. Assessment of Muscle Fatigue Associated with Prolonged Standing in the Workplace

    Science.gov (United States)

    Omar, Abdul Rahman; Saman, Alias Mohd; Othman, Ibrahim

    2012-01-01

    Objectives The objectives of this study were to determine the psychological fatigue and analyze muscle activity of production workers who are performing processes jobs while standing for prolonged time periods. Methods The psychological fatigue experienced by the workers was obtained through questionnaire surveys. Meanwhile, muscle activity has been analyzed using surface electromyography (sEMG) measurement. Lower extremities muscles include: erector spinae, tibialis anterior, and gastrocnemius were concurrently measured for more than five hours of standing. Twenty male production workers in a metal stamping company participated as subjects in this study. The subjects were required to undergo questionnaire surveys and sEMG measurement. Results Results of the questionnaire surveys found that all subjects experienced psychological fatigue due to prolonged standing jobs. Similarly, muscle fatigue has been identified through sEMG measurement. Based on the non-parametric statistical test using the Spearman's rank order correlation, the left erector spinae obtained a moderate positive correlation and statistically significant (rs = 0.552, p fatigue and to muscle fatigue among the production workers. PMID:22953228

  11. Radon measurements at IC-09 well of Chingshui geothermal field (Taiwan): A case study

    International Nuclear Information System (INIS)

    Chen, Y.; Kuo, T.; Fan, K.; Liang, H.; Tsai, C.; Chiang, C.; Su, C.

    2011-01-01

    Radon concentration was monitored during the flow tests of well IC-09 at the Chingshui geothermal field. The radon concentration was found to increase from 54 ± 29 to 983 ± 65 Bq/m 3 as a step function of production time, or cumulative production. The observed radon behavior can be explained by a radial composite model with the carbonate scales deposited in the skin zone near the well. The radius of skin zone near well IC-09 can be estimated with radon data at about 20 m using a plug flow model. Monitoring natural radon during the well flow tests is a helpful tracer to diagnose the formation damage near the well.

  12. A comparison of estimation methods for fitting Weibull, Johnson's SB and beta functions to Pinus pinaster, Pinus radiata and Pinus sylvestris stands in northwest Spain

    Energy Technology Data Exchange (ETDEWEB)

    Gorgoseo, J. J.; Rojo, A.; Camara-Obregon, A.; Dieguez-Aranda, U.

    2012-07-01

    The purpose of this study was to compare the accuracy of the Weibull, Johnson's SB and beta distributions, fitted with some of the most usual methods and with different fixed values for the location parameters, for describing diameter distributions in even-aged stands of Pinus pinaster, Pinus radiata and Pinus sylvestris in northwest Spain. A total of 155 permanent plots in Pinus sylvestris stands throughout Galicia, 183 plots in Pinus pinaster stands throughout Galicia and Asturias and 325 plots in Pinus radiata stands in both regions were measured to describe the diameter distributions. Parameters of the Weibull function were estimated by Moments and Maximum Likelihood approaches, those of Johnson's SB function by Conditional Maximum Likelihood and by Knoebel and Burkhart's method, and those of the beta function with the method based on the moments of the distribution. The beta and the Johnson's SB functions were slightly superior to Weibull function for Pinus pinaster stands; the Johnson's SB and beta functions were more accurate in the best fits for Pinus radiata stands, and the best results of the Weibull and the Johnson's SB functions were slightly superior to beta function for Pinus sylvestris stands. However, the three functions are suitable for this stands with an appropriate value of the location parameter and estimation of parameters method. (Author) 44 refs.

  13. Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.

    Science.gov (United States)

    1981-06-04

    suction return connection port will require the operator to secuire same from a squatting position. The present stowage arrangement on the test stand... SPC FC sample~~~ Iepal" -a *Tpoa _______Rate 7 eo3,t Sq,’ TPc owe te - U Enciosure ULeeds & Northrup N’AFC- 92- 1 0 Typical Plumbing Connections for

  14. Experimental and theoretical analysis of integrated circuit (IC) chips on flexible substrates subjected to bending

    Science.gov (United States)

    Chen, Ying; Yuan, Jianghong; Zhang, Yingchao; Huang, Yonggang; Feng, Xue

    2017-10-01

    The interfacial failure of integrated circuit (IC) chips integrated on flexible substrates under bending deformation has been studied theoretically and experimentally. A compressive buckling test is used to impose the bending deformation onto the interface between the IC chip and the flexible substrate quantitatively, after which the failed interface is investigated using scanning electron microscopy. A theoretical model is established based on the beam theory and a bi-layer interface model, from which an analytical expression of the critical curvature in relation to the interfacial failure is obtained. The relationships between the critical curvature, the material, and the geometric parameters of the device are discussed in detail, providing guidance for future optimization flexible circuits based on IC chips.

  15. Nasal and skin delivery of IC31(®)-adjuvanted recombinant HSV-2 gD protein confers protection against genital herpes.

    Science.gov (United States)

    Wizel, Benjamin; Persson, Josefine; Thörn, Karolina; Nagy, Eszter; Harandi, Ali M

    2012-06-19

    Genital herpes caused by herpes simplex virus type 2 (HSV-2) remains the leading cause of genital ulcers worldwide. Given the disappointing results of the recent genital herpes vaccine trials in humans, development of novel vaccine strategies capable of eliciting protective mucosal and systemic immune responses to HSV-2 is urgently required. Here we tested the ability of the adjuvant IC31(®) in combination with HSV-2 glycoprotein D (gD) used through intranasal (i.n.), intradermal (i.d.), or subcutaneous (s.c.) immunization routes for induction of protective immunity against genital herpes infection in C57BL/6 mice. Immunization with gD plus IC31(®) through all three routes of immunization developed elevated gD-specific serum antibody responses with HSV-2 neutralizing activity. Whereas the skin routes promoted the induction of a mixed IgG2c/IgG1 isotype profile, the i.n. route only elicited IgG1 antibodies. All immunization routes were able to induce gD-specific IgG antibody responses in the vaginas of mice immunized with IC31(®)-adjuvanted gD. Although specific lymphoproliferative responses were observed in splenocytes from mice of most groups vaccinated with IC31(®)-adjuvanted gD, only i.d. immunization resulted in a significant splenic IFN-γ response. Further, immunization with gD plus IC31(®) conferred 80-100% protection against an otherwise lethal vaginal HSV-2 challenge with amelioration of viral replication and disease severity in the vagina. These results warrant further exploration of IC31(®) for induction of protective immunity against genital herpes and other sexually transmitted infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Testing two novel stump-lifting heads in a final felling Norway spruce stand

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, K. (Metsaeteho Oy, Helsinki (Finland)), Email: kalle.karha@metsateho.fi; Mutikainen, A. (TTS Research, Rajamaeki (Finland)), Email: arto.mutikainen@tts.fi

    2009-07-01

    The use of stump and root wood chips has increased very rapidly in the 21st century in Finland: in the year 2000, the total consumption of stump wood chips for energy generation was 10 GWh, while in 2008 it was around 1.2 TWh. Metsaeteho Oy and TTS Research tested two new stump-lifting devices for lifting stumps in a final felling Norway spruce (picea abies) stand. In the time study with the Vaekevae Stump Processor lifting head, the productivity of stump lifting was 7,5 m3 / E{sub 0}-hour when lifting spruce stumps with a diameter of 30 cm from clayey soil, and 8.3 m3 /E{sub 0}-hour when lifting spruce stumps from sandy soil. When lifting stumps with a diameter of 40 cm, the stump-lifting productivity was 9.0 m3 /E{sub 0}-h (clay) and 10,5 m3 / E{sub 0}-h (sand). The results of this relatively restricted test indicated that the Vaekevae Stump Processor is s reliable and effective stump-lifting head that enables the harvesting of high-quality stump raw material for energy generation. The stump lifting productivity of the other lifting head (Jaervinen) was lower than that of the Vaekevae Strump Processor. Some development suggestions for the Jaervinen lifting head were presented and discussed. (orig.)

  17. Compatible growth models and stand density diagrams

    International Nuclear Information System (INIS)

    Smith, N.J.; Brand, D.G.

    1988-01-01

    This paper discusses a stand average growth model based on the self-thinning rule developed and used to generate stand density diagrams. Procedures involved in testing are described and results are included

  18. Model test on partial expansion in stratified subsidence during foundation pit dewatering

    Science.gov (United States)

    Wang, Jianxiu; Deng, Yansheng; Ma, Ruiqiang; Liu, Xiaotian; Guo, Qingfeng; Liu, Shaoli; Shao, Yule; Wu, Linbo; Zhou, Jie; Yang, Tianliang; Wang, Hanmei; Huang, Xinlei

    2018-02-01

    Partial expansion was observed in stratified subsidence during foundation pit dewatering. However, the phenomenon was suspected to be an error because the compression of layers is known to occur when subsidence occurs. A slice of the subsidence cone induced by drawdown was selected as the prototype. Model tests were performed to investigate the phenomenon. The underlying confined aquifer was generated as a movable rigid plate with a hinge at one end. The overlying layers were simulated with remolded materials collected from a construction site. Model tests performed under the conceptual model indicated that partial expansion occurred in stratified settlements under coordination deformation and consolidation conditions. During foundation pit dewatering, rapid drawdown resulted in rapid subsidence in the dewatered confined aquifer. The rapidly subsiding confined aquifer top was the bottom deformation boundary of the overlying layers. Non-coordination deformation was observed at the top and bottom of the subsiding overlying layers. The subsidence of overlying layers was larger at the bottom than at the top. The layers expanded and became thicker. The phenomenon was verified using numerical simulation method based on finite difference method. Compared with numerical simulation results, the boundary effect of the physical tests was obvious in the observation point close to the movable endpoint. The tensile stress of the overlying soil layers induced by the underlying settlement of dewatered confined aquifer contributed to the expansion phenomenon. The partial expansion of overlying soil layers was defined as inversed rebound. The inversed rebound was induced by inversed coordination deformation. Compression was induced by the consolidation in the overlying soil layers because of drainage. Partial expansion occurred when the expansion exceeded the compression. Considering the inversed rebound, traditional layer-wise summation method for calculating subsidence should be

  19. Monitoring System for Slope Stability under Rainfall by using MEMS Acceleration Sensor IC tags

    International Nuclear Information System (INIS)

    Murakami, S; Dairaku, A; Komine, H; Saito, O; Sakai, N; Isizawa, T; Maruyama, I

    2013-01-01

    Real-time warning system for slope failure under rainfall is available to disaster prevention and mitigation. Monitoring of multi-point and wireless measurements is effective because it is difficult to conclude the most dangerous part in a slope. The purpose of this study is to propose a method of monitoring system with multi-point and wireless measurements for a slope stability using MEMS acceleration sensor IC tags. MEMS acceleration sensor IC tag is an acceleration sensor microminiaturized by a technology of Micro Electro Mechanical Systems on board IC tag. Especially, low cost of the sensor will yield to the realization of the system. In order to investigate the applicability of the proposed system, a large-scale model test of artificial slope subjected to rainfall has been performed. MEMS acceleration sensor IC tags has been located on the slope and ground acceleration caused by forced vibration has been measured until the model slope collapses. The experimental results show that the MEMS acceleration sensor IC tag is comfortably available under rainfall, the characteristics of ground accelerations varies with changing the condition of the slope subjected to rainfall, and the proposed method can be applied to a real-time monitoring system for slope failure under rainfall.

  20. High technology at 'General Turbo', DH 12/13 balance-over speed testing stand

    International Nuclear Information System (INIS)

    Nuta, Florian Nicolae; Vasiliu, Dinu; Mauna, Traian

    2005-01-01

    'General Turbo' activity started in 1970 including building the balancing and over speed stand. DH 12/13 is the latest up-to-date facility of this type, the best one of the five in Europe, and was commissioned in 2004. The facility was especially built to be used for Romanian Nuclear Power Plant rotor testing and also for thermal very big rotors. The paper underlines the main attributes and the components of the facility DH 12/13 based on the Schenck technology. (authors)

  1. DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II

    Science.gov (United States)

    2017-01-13

    electric AC motor , and the two outputs of the axle are coupled using speed increasing gear boxes and absorbed by an identically sized AC motor ...work using the stationary axle efficiency test stand was completed using hardware representative of light and medium duty tactical wheeled vehicles ... vehicle results. However for the results to be applicable to real world field use , the driving cycle being replicated should be representative of real

  2. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    Science.gov (United States)

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r  = 0.446, p  Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  3. Forest volume-to-biomass models and estimates of mass for live and standing dead trees of U.S. forests.

    Science.gov (United States)

    James E. Smith; Linda S. Heath; Jennifer C. Jenkins

    2003-01-01

    Includes methods and equations for nationally consistent estimates of tree-mass density at the stand level (Mg/ha) as predicted by growing-stock volumes reported by the USDA Forest Service for forests of the conterminous United States. Developed for use in FORCARB, a carbon budget model for U.S. forests, the equations also are useful for converting plot-, stand- and...

  4. HI observations of the irregular galaxy IC 10

    International Nuclear Information System (INIS)

    Shostak, G.S.; Woerden, H. van

    1983-01-01

    The authors have made radio synthesis observations of the galaxy IC 10 with resolutions of 30 arcsec and 8 km/sec in the neutral hydrogen line using the Westerbork telescope. These confirm Shostak's (1974) result that, in the central region of IC 10, the velocity gradient is opposite to that later measured by single-dish in the outer regions. The suggestion by Cohen (1979) that the velocity gradient reversal is due to IC 10 being nearly face-on and warped is consistent with the new data. (Auth.)

  5. Are the General Medical Council's Tests of Competence fair to long standing doctors? A retrospective cohort study.

    Science.gov (United States)

    Mehdizadeh, Leila; Sturrock, Alison; Dacre, Jane

    2015-04-21

    The General Medical Council's Fitness to Practise investigations may involve a test of competence for doctors with performance concerns. Concern has been raised about the suitability of the test format for doctors who qualified before the introduction of Single Best Answer and Objective Structured Clinical Examination assessments, both of which form the test of competence. This study explored whether the examination formats used in the tests of competence are fair to long standing doctors who have undergone fitness to practise investigation. A retrospective cohort design was used to determine an association between year of primary medical qualification and doctors' test of competence performance. Performance of 95 general practitioners under investigation was compared with a group of 376 volunteer doctors. We analysed performance on knowledge test, OSCE overall, and three individual OSCE stations using Spearman's correlation and regression models. Doctors under investigation performed worse on all test outcomes compared to the comparison group. Qualification year correlated positively with performance on all outcomes except for physical examination (e.g. knowledge test r = 0.48, p fitness to practise investigation performed less well on the test of competence than their more recently qualified peers under investigation. The performance of the comparator group tended to stay consistent irrespective of year qualified. Our results suggest that the test format does not disadvantage early qualified doctors. We discuss findings in relation to the GMC's fitness to practise procedures and suggest alternative explanations for the poorer performance of long standing doctors under investigation.

  6. Bio-medical CMOS ICs

    CERN Document Server

    Yoo, Hoi-Jun

    2011-01-01

    This book is based on a graduate course entitled, Ubiquitous Healthcare Circuits and Systems, that was given by one of the editors. It includes an introduction and overview to biomedical ICs and provides information on the current trends in research.

  7. Design, building and testing of a stand alone fuel cell hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Segura, F.; Duran, E.; Andujar, J.M. [Department of Electronic, Computer Science and Automatic Engineering, University of Huelva (Spain)

    2009-08-01

    This paper designs, sizes, builds and tests a stand alone fuel cell hybrid system made up of a fuel cell stack and a battery bank. This system has been sized to supply a typical telecommunication load profile, but moreover, the system can supply other profiles. For this purpose, a modular low cost electronic load bank has been designed and built. This load bank allows the power demand to be chosen by selecting different solid state relays. Moreover, a virtual instrument based on NI Labview {sup registered} has been designed to select the load power demand from the computer. (author)

  8. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  9. Droplets bouncing on a standing wave field

    Science.gov (United States)

    Pucci, Giuseppe; Tambasco, Lucas; Harris, Daniel; Bush, John

    2017-11-01

    A liquid bath subject to a vertical vibration becomes unstable to standing surface waves at a critical vibrational acceleration known as the Faraday threshold. We examine the behavior of a millimetric droplet bouncing on the surface of a quasi-one-dimensional fluid channel above the Faraday threshold. We identify a sequence of bifurcations that occurs as the vibrational acceleration is increased progressively, ultimately leading to the erratic, diffusive motion of the droplet along the length of the channel. A simple theoretical model is presented. This work was supported by the US National Science Foundation through Grants CMMI-1333242 and DMS-1614043.

  10. Droplet-Wall/Film Impact in IC Engine Applications

    Science.gov (United States)

    2017-08-14

    Report: Droplet-Wall/ Film Impact in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) The views, opinions and/or findings...Participants: RPPR Final Report as of 12-Oct-2017 Agreement Number: W911NF-16-1-0449 Organization: Princeton University Title: Droplet-Wall/ Film Impact...droplets impacting a wet surface under various film thickness, which plays a critical role in controlling the efficiency of applications such as those

  11. Moral Rationality and Intuition: An Exploration of Relationships between the Defining Issues Test and the Moral Foundations Questionnaire

    Science.gov (United States)

    Glover, Rebecca J.; Natesan, Prathiba; Wang, Jie; Rohr, Danielle; McAfee-Etheridge, Lauri; Booker, Dana D.; Bishop, James; Lee, David; Kildare, Cory; Wu, Minwei

    2014-01-01

    Explorations of relationships between Haidt's Moral Foundations Questionnaire (MFQ) and indices of moral decision-making assessed by the Defining Issues Test have been limited to correlational analyses. This study used Harm, Fairness, Ingroup, Authority and Purity to predict overall moral judgment and individual Defining Issues Test-2 (DIT-2)…

  12. Self-standing paper based anodes prepared from siliconcarbonitride-MoS2 composite for Li-ion battery applications

    Science.gov (United States)

    David, Lamuel; Singh, Gurpreet

    2013-03-01

    We study synthesis of free-standing polymer derived SiCN/ MoS2 composite paper anode for Li-ion battery application. This was achieved following a two-step approach: First, polysilazane was interfaced with exfoliated MoS2 nanosheets which upon pyrolysis resulted in SiCN/MoS2 composite. Second, dispersion of SiCN/MoS2 in isopropanol was vacuum filtered resulting in formation of a self-standing composite paper. Physical and chemical characterization of the composite was carried out by use of electron microscopy, Fourier transform infrared spectroscopy (FT-IR) and Thermo-gravimetric analysis (TGA). FT-IR data indicated complete conversion of polysilazane precursor to SiCN ceramic, while electron microscopy confirmed layered structure of the paper. Thermo-gravimetric analysis showed enhanced thermodynamic stability of the composite paper up to 800 °C. Electrochemical analysis of SiCN/MoS2 composite paper anodes showed that Li-ion can reversible intercalate in the voltage range of 0-2.5 V with a first cycle discharge capacity of 770 mAh/g at a current density of 100 mA/g.

  13. Lateral loading test of full-scaled pile foundation focused on ultimate behavior; Shukyoku kyodo ni chakumokushita jitsubutsudai kui kiso no suihei saika shiken

    Energy Technology Data Exchange (ETDEWEB)

    Kosa, K. [Hanshin Expressway Public Corp., Osaka (Japan); Suzuki, N. [CTI Engineering Co. Ltd., Tokyo (Japan); Kimura, M. [Kyoto University, Kyoto (Japan); Kimura, Y. [Public Works Research Institute, Tsukuba (Japan); Morita, Y. [Kiso-Jiban Consultants Co. Ltd., Tokyo (Japan)

    1998-06-21

    Lateral loading test of full-scaled pile foundation was made up to the ultimate limit state to establish a limit state design method for pile foundations. A full-scaled 3-by-3 pile group driven as bridge foundation was used for the test. A surface reclaimed layer is nearly 13cm in thickness. The lateral unidirectional loading test was repeatedly carried out by using 6 hydraulic jacks at 30MN in maximum load capacity and 50cm in maximum allowable deformation. The test and analysis results are as follows. In a range of 0-40% in pile head displacement/pile diameter ratio, a load-carrying capacity increased gradually. The yield point of a load-displacement curve agreed with the point at which a reinforcing bar of a pile body reaches analytical yield stress. Bending moment of a pile body and shear stress of a pile head increased in the order of back, middle and front rows. It was confirmed that a framework analysis method considering the non-linearity of a pile body and bedrock is also applicable to full-scaled pile group foundations. 17 refs., 32 figs., 3 tabs.

  14. National Headache Foundation

    Science.gov (United States)

    ... Headache Topic Sheets (Spanish) Headache FAQ NHF Webinars Education Modules MigrainePro™ Children’s Headache Disorders New Perspectives on Caffeine and Headache War Veterans Health Resource Initiative National Headache Foundation Brochures ...

  15. Nanometer CMOS ICs from basics to ASICs

    CERN Document Server

    J M Veendrick, Harry

    2017-01-01

    This textbook provides a comprehensive, fully-updated introduction to the essentials of nanometer CMOS integrated circuits. It includes aspects of scaling to even beyond 12nm CMOS technologies and designs. It clearly describes the fundamental CMOS operating principles and presents substantial insight into the various aspects of design implementation and application. Coverage includes all associated disciplines of nanometer CMOS ICs, including physics, lithography, technology, design, memories, VLSI, power consumption, variability, reliability and signal integrity, testing, yield, failure analysis, packaging, scaling trends and road blocks. The text is based upon in-house Philips, NXP Semiconductors, Applied Materials, ASML, IMEC, ST-Ericsson, TSMC, etc., courseware, which, to date, has been completed by more than 4500 engineers working in a large variety of related disciplines: architecture, design, test, fabrication process, packaging, failure analysis and software.

  16. Current status of ITER I&C system as integration begins

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William, E-mail: william.davis@iter.org [ITER Organisation, Route de Vinon-sur Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Wallander, Anders [ITER Organisation, Route de Vinon-sur Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Yonekawa, Izuru [Nippon Advanced Technology Ltd., 3129-45 Hibara Muramatsu, Tokai, Naka-gun, Ibaraki 319-1112 (Japan)

    2016-11-15

    Highlights: • The ITER I&C system is organisationally complicated and technically challenging. • Standard technologies for the ITER I&C systems have been selected. • Supply of non-standard technologies will cause serious issues. • Differing levels of design maturity of plant I&C systems is a serious challenge. • Systems are in the final stages of design and are being delivered to site. - Abstract: The ITER I&C system is organisationally complicated and technically challenging, and integrating its many sub-systems into a single coherent system is critical for the ITER project to meet its objectives. This paper explains the integration risks being faced now and anticipated in the near future. Standardisation initiatives by the ITER central team to mitigate these risks are described. The paper also presents the architecture of the ITER I&C system, the current status of design and manufacture key developments made in recent years, and the current and future activities of the central I&C teams. Finally, a short description is given of the plant I&C systems that will be delivered to ITER in the near future.

  17. El contenido de los mensajes icónicos: El discurso icónico como totalidad (2)

    OpenAIRE

    Dr. Raymond Colle

    1999-01-01

    En el capítulo anterior, hemos hablado de los códigos icónicos de modo general, por cuanto tienen algunas características comunes, en particular el uso de figuras como factores de los significantes. Sin embargo, como lo hemos señalado al final, no todos se construyen ni articulan de la misma manera. Tal como las lenguas son muchas y los códigos lingüísticos se rigen por diferentes reglas -aunque sobre la base de fonemas unidos secuencialmente-, los códigos icónicos son también variados y regi...

  18. The effect of a hybrid assistive limb® on sit-to-stand and standing patterns of stroke patients

    Science.gov (United States)

    Kasai, Rie; Takeda, Sunao

    2016-01-01

    [Purpose] The Hybrid Assistive Limb® (HAL®) robot suit is a powered exoskeleton that can assist a user’s lower limb movement. The purpose of this study was to assess the effectiveness of HAL® in stroke rehabilitation, focusing on the change of the sit-to-stand (STS) movement pattern and standing posture. [Subjects and Methods] Five stroke patients participated in this study. Single leg HAL® was attached to each subject’s paretic lower limb. The subjects performed STS three times both with and without HAL® use. A tri-axial accelerometer was used to assess the STS movement pattern. Forward-tilt angle (FTA) and the time required for STS were measured with and without HAL® use. Surface electromyography (EMG) of STS and standing were recorded to assess the vastus medialis muscle activities of the paretic limb. [Results] The average FTA without HAL® use was 35° and it improved to 43° with HAL® use. The time required for STS was longer for all subjects with HAL® use (without HAL® use: 3.42 s, with HAL® use: 5.11 s). The integrated EMGs of HAL® use compared to those without HAL®, were 83.6% and 66.3% for STS and standing, respectively. [Conclusion] HAL® may be effective in improving STS and standing patterns of stroke patients. PMID:27390416

  19. Seismic design method of free standing rack

    International Nuclear Information System (INIS)

    Taniguchi, Katsuhiko; Okuno, Daisaku; Iwasaki, Akihisa; Nekomoto, Yoshitsugu; Matsuoka, Toshihiro

    2013-01-01

    For high earthquake resistance and ease of installation, free standing racks which are not anchored to the pool floor or walls has been adopted in many countries. Under the earthquake, the response of the free standing rack is highly nonlinear and involves a complex combination of motions (sliding, rocking, twisting, and turning) and impacts between the fuel assemblies and the fuel cell walls, rack-to-rack, and the pit floor and rack pedestals. We carried out seismic experiments on the full-scale rack model in water and dry conditions to obtain the fundamental data about free standing rack (sliding, rocking and turning motions). We have developed the nonlinear dynamic analysis method to predict seismic response for the free standing rack utilizing the full-scale test result and verified the analysis evaluation method of the rack by comparison of test result. (author)

  20. A CENSUS OF YOUNG STARS AND BROWN DWARFS IN IC 348 AND NGC 1333

    Energy Technology Data Exchange (ETDEWEB)

    Luhman, K. L.; Esplin, T. L. [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Loutrel, N. P., E-mail: kluhman@astro.psu.edu [Department of Physics, Montana State University, Bozeman, MT 59715 (United States)

    2016-08-10

    We have obtained optical and near-infrared spectra of candidate members of the star-forming clusters IC 348 and NGC 1333. We classify 100 and 42 candidates as new members of the clusters, respectively, which brings the total numbers of known members to 478 and 203. We also have performed spectroscopy on a large majority of the previously known members of NGC 1333 in order to provide spectral classifications that are measured with the same scheme that has been applied to IC 348 in previous studies. The new census of members is nearly complete for K {sub s}< 16.8 at A {sub J}< 1.5 in IC 348 and for K {sub s}< 16.2 at A {sub J}< 3 in NGC 1333, which correspond to masses of ≳0.01 M {sub ⊙} for ages of 3 Myr according to theoretical evolutionary models. The faintest known members extend below these completeness limits and appear to have masses of ∼0.005 M {sub ⊙}. In extinction-limited samples of cluster members, NGC 1333 exhibits a higher abundance of objects at lower masses than IC 348. It would be surprising if the initial mass functions of these clusters differ significantly given their similar stellar densities and formation environments. Instead, it is possible that average extinctions are lower for less massive members of star-forming clusters, in which case extinction-limited samples could be biased in favor of low-mass objects in the more heavily embedded clusters like NGC 1333. In the Hertzsprung–Russell diagram, the median sequences of IC 348 and NGC 1333 coincide with each other for the adopted distances of 300 and 235 pc, which would suggest that they have similar ages. However, NGC 1333 is widely believed to be younger than IC 348 based on its higher abundance of disks and protostars and its greater obscuration. Errors in the adopted distances may be responsible for this discrepancy.

  1. Heat Loss Testing of Schott's 2008 PTR70 Parabolic Trough Receiver

    Energy Technology Data Exchange (ETDEWEB)

    Burkholder, Frank [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kutscher, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2009-05-01

    Two Schott 2008 model year PTR70 HCEs were tested on NREL's heat loss test stand from 100 - 500 deg C in 50 deg C increments. Absorber emittance was determined from the laboratory testing so that the performance of the HCEs could be modeled in a parabolic trough collector. Collector/HCE simulation results for many different field operation conditions were used to create heat loss correlationcoefficients for Excelergy and SAM. SAM estimates that the decreased emittance of the 2008 PTR70 will decrease the LCOE for parabolic trough power plants by 0.5 cents/kWh and increase the electricity generated by 5% relative to previous PTR70s. These conclusions assume that the 2008 PTR70 is supplied at the same cost and with the same optical performance as earlier PTR70 models.

  2. IMMEDIATE CONSTITUENT ANALYSIS (IC analysis DİREKT BİLEŞENLER ANALİZİ

    Directory of Open Access Journals (Sweden)

    Muzaffer MALKOÇ

    2011-06-01

    Full Text Available IC analysis is a method of sentence analysis first explicitly introduced by American linguist Leonard Bloomfield in his book, Language, in 1933, though the underlying principle is common both to the traditional practice of parsing and to many modern systems of grammatical analysis. In IC analysis, a sentence is divided up into major divisions or immediate constituents, and these constituents are in turn divided into further immediate constituents. This process continues until irreducible constituents are reached, i.e., until each constituent consists of only a word or meaningful part of a word. The important tests used to analyze the sentences are deletion, permutation, transformation, and substitution tests.The end result of an IC analysis is often presented in a visual diagrammatic form that reveals the hierarchical immediate constituent structure of a sentence Direkt bileşenler analiz metodu Amerikalı dil bilimci Leonard Bloomfield tarafından 1933 yılında sentaks alanında başlatılmış, daha sonraki yıllarda fonetik ve morfoloji alanlarında da uygulanmıştır. Bu analiz metodunun amacı tümce veya kelime gruplarının parçalanması ve tasnif edilmesi işleminden ibarettir. Tümcelerin parçalanması en küçük dil birimine kadar kademe kademe yapılmalı ve bileşenlerin sınıflandırılmasında ise ana öbeğe veya ana gövdeye daha yakın olan unsurlar ile ikincil öğeler analizin amacına uygun olarak belirtilmelidir. Bu işlemler yapılırken Yok Etme Testi, Yer Değiştirme Testi, Dönüştürme Testi, Yerine Koyma Testi gibi metotlardan faydalanılır. Bu prensipler çerçevesinde yapılan analizin sonuçları hiyerarşik yapıları göstermek için bir grafikle özetlenir

  3. Integrated System Health Management (ISHM) for Test Stand and J-2X Engine: Core Implementation

    Science.gov (United States)

    Figueroa, Jorge F.; Schmalzel, John L.; Aguilar, Robert; Shwabacher, Mark; Morris, Jon

    2008-01-01

    ISHM capability enables a system to detect anomalies, determine causes and effects, predict future anomalies, and provides an integrated awareness of the health of the system to users (operators, customers, management, etc.). NASA Stennis Space Center, NASA Ames Research Center, and Pratt & Whitney Rocketdyne have implemented a core ISHM capability that encompasses the A1 Test Stand and the J-2X Engine. The implementation incorporates all aspects of ISHM; from anomaly detection (e.g. leaks) to root-cause-analysis based on failure mode and effects analysis (FMEA), to a user interface for an integrated visualization of the health of the system (Test Stand and Engine). The implementation provides a low functional capability level (FCL) in that it is populated with few algorithms and approaches for anomaly detection, and root-cause trees from a limited FMEA effort. However, it is a demonstration of a credible ISHM capability, and it is inherently designed for continuous and systematic augmentation of the capability. The ISHM capability is grounded on an integrating software environment used to create an ISHM model of the system. The ISHM model follows an object-oriented approach: includes all elements of the system (from schematics) and provides for compartmentalized storage of information associated with each element. For instance, a sensor object contains a transducer electronic data sheet (TEDS) with information that might be used by algorithms and approaches for anomaly detection, diagnostics, etc. Similarly, a component, such as a tank, contains a Component Electronic Data Sheet (CEDS). Each element also includes a Health Electronic Data Sheet (HEDS) that contains health-related information such as anomalies and health state. Some practical aspects of the implementation include: (1) near real-time data flow from the test stand data acquisition system through the ISHM model, for near real-time detection of anomalies and diagnostics, (2) insertion of the J-2X

  4. U.S. uranium supply to the research and test reactor community

    International Nuclear Information System (INIS)

    Parker, Elaine M.

    2002-01-01

    From the 1950s through the early 1990s, the U.S. Department of Energy (DOE) was the primary supplier of low enriched uranium (LEU) and highly enriched uranium (HEU) to research and test reactors worldwide. The formerly called Y-12 Plant in Oak Ridge, Tennessee, was put into operational stand down in 1994 due to inadequate safety documentation. This paper will discuss the re-start of the Y-12 Plant and its current capabilities. Additionally, the paper will address recent changes within the DOE, with the creation of the National Nuclear Security Administration (NNSA). It will show how the change to NNSA and an organizational re-alignment has improved efficiencies. NNSA is committed to operate its sales program so that it is complementary to, and in support of, the Reduced Enrichment for Research and Test Reactors (RERTR) and Foreign Research Reactor Spent Nuclear Fuel (FRR SNF) Return Programs. The NNSA is committed to provide an assurance of competitively-priced, high-quality uranium supply to the research and test reactor community under long-term contracts. This paper will discuss some of NNSA's recent successes in long-term contracting and meeting deliveries. (author)

  5. Electron Storage Ring Development for ICS Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loewen, Roderick [Lyncean Technologies, Inc., Palo Alto, CA (United States)

    2015-09-30

    There is an increasing world-wide interest in compact light sources based on Inverse Compton Scattering. Development of these types of light sources includes leveraging the investment in accelerator technology first developed at DOE National Laboratories. Although these types of light sources cannot replace the larger user-supported synchrotron facilities, they offer attractive alternatives for many x-ray science applications. Fundamental research at the SLAC National Laboratory in the 1990’s led to the idea of using laser-electron storage rings as a mechanism to generate x-rays with many properties of the larger synchrotron light facilities. This research led to a commercial spin-off of this technology. The SBIR project goal is to understand and improve the performance of the electron storage ring system of the commercially available Compact Light Source. The knowledge gained from studying a low-energy electron storage ring may also benefit other Inverse Compton Scattering (ICS) source development. Better electron storage ring performance is one of the key technologies necessary to extend the utility and breadth of applications of the CLS or related ICS sources. This grant includes a subcontract with SLAC for technical personnel and resources for modeling, feedback development, and related accelerator physics studies.

  6. Confirmation test on the dynamic interaction between a model reactor-building foundation and ground in the Sendai Nuclear Power Station

    International Nuclear Information System (INIS)

    Umezu, Hideo; Kisaki, Noboru; Shiota, Mutsumi

    1982-01-01

    On the site of unit 2 (planned) in the Sendai Nuclear Power Station, a model reactor-building foundation of reinforced concrete with diameter of 12 m and height of 5 m was installed. With a vibration generator, its forced vibration tests were carried out in October to December, 1980. Valuable data were able to be obtained on the dynamic interaction between the model foundation and the ground, and also the outlook for the application of theories in hard base rock was obtained. (1) The resonance frequency of the model foundation in horizontal vibration was 35 Hz in both NS and EW directions. (2) Remarkable difference was not observed in the horizontal vibration behavior between NS and EW directions, so that there is not anisotropy in the ground. (3) The model foundation was deformed nearly as a rigid body. (J.P.N.)

  7. Relationships between Charpy impact shelf energies and upper shelf Ksub(IC) values for reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Witt, F.J.

    1983-01-01

    Charpy shelf data and lower bound estimates of Ksub(IC) shelf data for the same steels and test temperatures are given. Included are some typical reactor pressure vessel steels as well as some less tough or degraded steels. The data were evaluated with shelf estimates of Ksub(IC) up to and exceeding 550 MPa√m. It is shown that the high shelf fracture toughness representative of tough reactor pressure vessel steels may be obtained from a knowledge of the Charpy shelf energies. The toughness transition may be obtained either by testing small fracture toughness specimens or by Charpy energy indexing. (U.K.)

  8. Optical transceiver ICs based on 3D die-stacking of opto-electronic devices

    NARCIS (Netherlands)

    Duan, P.; Raz, O.; Smalbrugge, B.E.; Plassche, van de K.L.; Dorren, H.J.S.

    2013-01-01

    Wafer scale fabrication of the 3D stacked transceivers is discussed. Uniform open eye patterns at 10 Gb/s/channel of both 3D stacked transmitter and receiver ICs indicates that the interconnection technology is robust.

  9. Definition of intercultural competence (IC) in undergraduate students at a private university in the USA: A mixed-methods study.

    Science.gov (United States)

    Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne; Kedzior, Karina Karolina

    2018-01-01

    Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the

  10. The role of forest stand structure as biodiversity indicator

    DEFF Research Database (Denmark)

    Gao, Tian; Hedblom, Marcus; Emilsson, Tobias

    2014-01-01

    be achieved if indicators are derived from existing data. In this study, a model for classifying forest stand structures was developed and tested as an indicator of overall plant species diversity at stand level. The model combines four stand structure parameters: canopy coverage, age of canopy trees, tree...... species composition and canopy stratification. Using data from the National Inventory of Landscapes in Sweden and General Linear Mixed Model, plant species diversity (Shannon diversity index, SHDI) and composition (Sørensen-Dice index, SDI) were tested between 26 different stand structure types and nine...... soil classes. The results showed that mature stands with a stratified canopy had the highest plant species diversity across the soil classes, particularly if they comprised mixed coniferous and broadleaved species with a semi-open canopy. In contrast, young (...

  11. A study on special test stand of automatic and manual descent control in presence of simulated g-load effect

    Science.gov (United States)

    Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav

    The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.

  12. Professional Team Foundation Server 2010

    CERN Document Server

    Blankenship, Ed; Holliday, Grant; Keller, Brian

    2011-01-01

    Authoritative guide to TFS 2010 from a dream team of Microsoft insiders and MVPs!Microsoft Visual Studio Team Foundation Server (TFS) has evolved until it is now an essential tool for Microsoft?s Application Lifestyle Management suite of productivity tools, enabling collaboration within and among software development teams. By 2011, TFS will replace Microsoft?s leading source control system, VisualSourceSafe, resulting in an even greater demand for information about it. Professional Team Foundation Server 2010, written by an accomplished team of Microsoft insiders and Microsoft MVPs, provides

  13. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem

    OpenAIRE

    Muller , Antoine; Pontonnier , Charles; Dumont , Georges

    2018-01-01

    International audience; The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions – two polynomial criteria and a min/max criterion – were tested on a planar musculoskeletal model. The MusIC method provides a computation frequenc...

  14. Fertilizing of mixed stands in a smoke-damaged region of the Erzgebirge range

    Energy Technology Data Exchange (ETDEWEB)

    Trillmich, H D

    1969-01-01

    Three mixed stands established in a S.E. German area of chronic pollution (no lichens were found in the stands) in 1933 to 1941 responded positively to fertilizers (PKCaMg in 1938 to 1942 and NPKCaMg in 1960 to 1964). Scots Pine responded less than Norway Spruce, Larch, and Beech, and differences between species affected stand structure. Tests on Scots Pine and Norway Spruce showed better color, weight, length and number of needles, compared with untreated controls, but only in Pine was there an increase in the number of older needles. Analyses of Spruce needles showed increases in nutrient contents vs. untreated controls (which showed no deficiencies, except perhaps of N). 11 references, 12 tables.

  15. Dynamic scour protection for off-shore wind turbine foundations. Edge scour tests and results

    Energy Technology Data Exchange (ETDEWEB)

    Kularatne, K.A.S.R.; Sumer, B.M.; Fredsoee, J.

    2002-07-01

    Sufficient protection cover for the foundation of offshore wind turbines is an essential part in maintaining the stability of the structure. In addition to the danger caused by the flow conditions existing in the sea, a sudden change in the bed topography would definitely cause a greater risk on the stability of a structure. A movement of a sand bank close to the structure could be one of the common examples of that kind. Therefore, the main objective of the present study is to investigate the scour process at the tip of a scour protection for an offshore wind turbine foundation under a steady uniform flow parallel to the structure, while a sand bank is moving close by. The physical model of a scour protection for an offshore wind turbine foundation, which forms basis for this report, was constructed in the 23m long, 2m wide and 0.5m deep steady flow fume of ISVA, Technical University of Denmark. The processes of scouring and settlement of stones mainly close to the tip of the protection layer were monitored under number of different flow and bottom conditions such as flow velocity (Shields parameter), slope of the sand bank, number of scour protection layers and different lateral slopes of the sand bank. All the tests were conducted under live-bed conditions. After 10 different tests, the following conclusions were reached: 1. Formation of horseshoe vortex in front of the scour protection layer and the contraction of streamlines due to the obstruction caused by the scour protection were identified as the major mechanisms of scour causing instability of stones, 2. When a lateral slope was present, on top of the two major mechanisms the scouring originated from the toe of the lateral slope too apparently propagated towards the joint between the sand bed and the scour protection, 3. The maximum scour depth normalized by the stone size (S/D) found increase with the Shields parameter but for higher values of Shields parameter it becomes pronounced, 4. The slope of the

  16. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Science.gov (United States)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  17. Optimization of the stand for test of hybrid rocket engines of solid fuel

    Directory of Open Access Journals (Sweden)

    Zolotorev Nikolay

    2017-01-01

    Full Text Available In the paper the laboratory experimental stand of the hybrid rocket engine of solid fuel to study ballistic parameters of the engine at burning of high-energy materials in flow of hot gas is presented. Mixture of air with nitrogen with a specified content of active oxygen is used as a gaseous oxidizer. The experimental stand has modular design and consists of system of gas supply, system of heating of gas, system for monitoring gas parameters, to which a load cell with a model engine was connected. The modular design of the stand allows to change its configuration under specific objective. This experimental stand allows to conduct a wide range of the pilot studies at interaction of a hot stream of gas with samples high-energy materials.

  18. Monopod bucket foundations under cyclic lateral loading

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo

    on bucket foundations under lateral cyclic loading. The test setup is described in detail and a comprehensive experimental campaign is presented. The foundation is subjected to cyclic overturning moment, cyclic horizontal loading and constant vertical loading, acting on the same plane for thousands...

  19. Simulated stand tests and centrifuge training to prevent orthostatic intolerance on Earth, moon, and Mars.

    Science.gov (United States)

    Coats, Brandon W; Sharp, M Keith

    2010-03-01

    One proposed method to overcome postflight orthostatic intolerance is for astronauts to undergo inflight centrifugation. Cardiovascular responses were compared between centrifuge and gravitational conditions using a seven-compartment cardiovascular model. Vascular resistance, heart rate, and stroke volume values were adopted from literature, while compartmental volumes and compliances were derived from impedance plethysmography of subjects (n=8) riding on a centrifuge. Three different models were developed to represent the typical male subject who completed a 10-min postflight stand test ("male finisher"), "non-finishing male" and "female" (all non-finishers). A sensitivity analysis found that both cardiac output and arterial pressure were most sensitive to total blood volume. Simulated stand tests showed that female astronauts were more susceptible to orthostatic intolerance due to lower initial blood pressure and higher pressure threshold for presyncope. Rates of blood volume loss by capillary filtration were found to be equivalent in female and male non-finishers, but four times smaller in male finishers. For equivalent times to presyncope during centrifugation as those during constant gravity, lower G forces at the level of the heart were required. Centrifuge G levels to match other cardiovascular parameters varied depending on the parameter, centrifuge arm length, and the gravity level being matched.

  20. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  1. Centrifuge Testing and Seismic Response Analysis for Uplift Behavior of Spread Foundation Structures on Rock

    Directory of Open Access Journals (Sweden)

    Takuya Suzuki

    2016-09-01

    Full Text Available The uplift behavior of structures subjected to severe seismic motion has not been clarified. This paper presents experimental and analytical studies conducted for clarifying this problem of spread foundation structures on rock. First, centrifugal loading tests are conducted to determine the uplift behavior of these structures, and the uplift behavior of these structures is confirmed. Then, simulation analyses are performed using a three-dimensional FE model and the accuracy of these analyses is confirmed. A comparison between test and analyses results clarified the important analytical conditions required for maintaining analysis precision and the limit of analysis precision.

  2. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  3. Evaluating the philosophical foundation of 2013 Curriculum

    Directory of Open Access Journals (Sweden)

    M. Mardiana

    2017-12-01

    Full Text Available The study was to: (1 identify the interpretation toward the philosophical foundation of 2013 Curriculum; and (2 evaluate the philosophical foundation of 2013 Curriculum. In order to achieve these objectives, the researchers implemented the method of philosophy interpretation, namely a method that might discover an individual’s paradigm through the texts or the articles that he or she composed. Furthermore, in order to evaluate the philosophical foundation of 2013 Curriculum the researchers implemented certain criteria and this effort was supported by the expert interview. The data were analyzed by means of hermeneutic method, namely the presence of a relationship among the three elements namely text, interpreter and reader. The conclusions of the study then were as follows: (1 the interpretation toward the philosophical foundation of 2013 Curriculum contained six points namely: (a establishing and developing the nation’s attitude and civilization or the nation’s character, (b developing the curriculum based on the nation’s culture, (c referring to the fact that education had been a process of developing the learning participants’ potentials, (d referring to the fact that education had been based on the nation’s culture and experience in the past, (e referring to the fact that education had been basis of the nation’s life continuity and (f Referring to the fact that education had been adjusted to the life of the learning participants as an individual, a society member and a citizen; (2 the six philosophical reasons namely: (a perennialism, (b essentialism, (c progressivism, (d pragmatism, (e existentialism and (f reconstructionism; (3 the following evaluation results: (a the philosophical foundation of 2013 Curriculum based on the interpretation results had provided clear educational objectives and functions, (b the philosophical foundation of 2013 Curriculum had been in accordance to facts, (c the philosophical foundation of 2013

  4. The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, T.; Kashiwagi, S.; Nakano, S.; Takasago, T.; Abiko, S.; Shiroyama, Y.; Hayashi, M.; Ito, H. (Yamaguchi Univ. School of Medicine (Japan). Dept. of Neurosurgery)

    1991-06-01

    Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced CRC or reduced CBF with reduced CRC are criteria for selection of candidates for bypass surgery. We conclude that Xe-CT with the Diamox test is a useful and simple method for evaluating cerebral hemodynamics. Preoperative grouping with a combination of preoperative resting rCBF and preoperative rCRC is useful for predicting the effect of EC-IC bypass surgery. (orig.).

  5. Metabolic syndrome in people with a long-standing spinal cord injury: associations with physical activity and capacity.

    Science.gov (United States)

    de Groot, Sonja; Adriaansen, Jacinthe J; Tepper, Marga; Snoek, Govert J; van der Woude, Lucas H V; Post, Marcel W M

    2016-11-01

    This study investigated (i) the prevalence of the metabolic syndrome (MetS) in people with a long-standing spinal cord injury (SCI); (ii) whether personal or lesion characteristics are determinants of the MetS; and (iii) the association with physical activity or peak aerobic capacity on the MetS. In a cross-sectional study, persons with SCI (N = 223; time since injury of ≥10 years) were tested. The individual components of the MetS were assessed together with the physical activity measured by the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD), while peak aerobic capacity was tested during a graded wheelchair exercise test on a treadmill. Thirty-nine percent of the participants had MetS. In a multivariate logistic regression analyses and after performing a backward regression analysis, only age and education were significant determinants of the MetS. A 10-year increase in age leads to a 1.5 times more chance to have the MetS. Furthermore, people with a low education will multiply the relative risk of MetS compared with people with high education by almost 2. With and without correcting for confounders, no significant relationship was found between PASIPD or peak aerobic capacity and the MetS. It can be concluded that the prevalence of the MetS is high (39%) in people with a long-standing SCI but is comparable to the general Dutch population. Older people and those with a lower education level are most at risk for the MetS. Physical activity and peak aerobic fitness were not related to the MetS in this group with a long-standing SCI.

  6. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  7. Adopting De Novo Programming Approach on IC Design Service Firms Resources Integration

    Directory of Open Access Journals (Sweden)

    James K. C. Chen

    2014-01-01

    Full Text Available The semiconductor industry has very important position in computer industry, ICT field, and new electronic technology developing. The IC design service is one of key factor of semiconductor industry development. There are more than 365 IC design service firms have been established around Hsinchu Science Park in Taiwan. Building an efficient planning model for IC design service firm resources integrating is very interest issue. This study aims to construct a planning model for IC design service firm implementation resources integration. This study uses the De Novo programming as an approach of criteria alternative to achieve optimal resource allocation on IC design firm. Results show the IC design service firm should conduct open innovation concept and utilizes design outsourcing obtains cost down and enhance IC design service business performance. This plan model of De Novo programming is not only for IC design service firm and also can apply to the other industrial implementation strategic alliance/integrating resource. This plan model is a universal model for the others industries field.

  8. Apparatus and method for defect testing of integrated circuits

    Science.gov (United States)

    Cole, Jr., Edward I.; Soden, Jerry M.

    2000-01-01

    An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.

  9. RESEARCH OF THE FOUNDATION CONSOLIDATED BY DIFFERENT-SIZED HORIZONTAL ELEMENTS

    Directory of Open Access Journals (Sweden)

    Isakova Elena Aleksandrovna

    2016-05-01

    Full Text Available The article is dedicated to the problem of geotechnics. The problems of the weak soil base are topical. Also there sometimes happen severe accidents of soil mass. A great number of such emergencies is of a progressive character, when a local crash leads to the crash of the whole construction. Tarring the soil with epoxy can ensure geotechnical safety of the basis. That’s why the improvement of this method is needed in order to reduce yielding of the base, create ground water cutoff or create building hoisting. In the article new structural solutions for reduction of settlement are presented. The authors suggest using the manufactured plane elements containing epoxy. Such elements have different sizes and lie underneath the foundation. Similar structural scheme can be used to reduce soil settlement. The authors carried out two series of plate-bearing model tests with manufactured plane epoxy elements. In the first series of tests the biggest element was closer to the foundation, the smallest element was closer to the biggest element. In the second series of tests the smallest element was closer to the foundation, the biggest element was closer to the smallest element. After the end of plate-bearing model tests the authors received values of the base settlement and the dependency diagrams “base settlement-soil pressure”. The new structural solution for reducing soil settlement proved to be effective. Settlement of base decreased sevenfold.

  10. Test work of sand compaction pile method on coal ash soil foundation. Sekitanbai jiban ni okeru sand compaction pile koho no shiken seko

    Energy Technology Data Exchange (ETDEWEB)

    Goto, K.; Maeda, S.; Shibata, T. (The Kansai Electric Power Co. Inc., Osaka (Japan))

    1992-01-25

    As an electric power supply source after the 1990 {prime}s, Nos. 5 and 6 units are additionally being constructed by Kansai Electric Power in its Himeji Power Station No.1 which is an exclusively LNG burning power station. The additional construction site of those units is of soil foundation reclaimed with coal ash which was used residual product in the existing No.1 through No.4 units. As a result of soil foundation survey, the coal ash layer and sand layer were known to be of material to be possibly liquidized at the time of earthquake. As measures against the liquidization, application was basically made of a sand compaction pile (SCP) method which is economical and abundant in record. However, that method was so short of record in the coal ash layer that its evaluation was difficult in soil reforming effect. Therefore, its applicability was evaluated by a work test on the site, which resulted in a confirmation that the coal ash as well as the sand can be sufficiently reformed by the SCP method. Started in September, 1991, the additional construction of Nos. 5 and 6 units in Himeji Power Station No.1 uses a 1.5m pitch SCP method to reform the soil foundation. 3 refs., 10 figs., 1 tab.

  11. The stand prototype of minimum power NRE reactor

    International Nuclear Information System (INIS)

    Belogurov, A.I.; Grigorenko, L.N.; Mamontov, Yu.I.; Rachuk, V.S.; Stukalov, A.I.; Konyukhov, G.V.

    1995-01-01

    For ensuring of full-scale development of nuclear rocket engine (NRE) reactor was created stand prototype (reactor IRGIT?) The main differences of its are as follows: 1) Fasteners of technologies channels contents fuel assemblies in bottom are worked out the split. It is provides possibility a distance channels change without disassembly of reactor stand prototype from stand; 2) Cooling of the vessels, the moderator, the reflector and the barrel actuate is carried out by hydrogen; 3) The lower bottom modified for organization the hydrogen efflux in the form a reactor jet; 4) Radiation defence is introduced as part of stand prototype for ensuring of serviceability of stand accessories and tests routine service; 5) Each technology channels is provided of critical nozzle; 6) Control, regulation and defence of reactor has being carried out on stand system

  12. The front end test stand high performance H- ion source at Rutherford Appleton Laboratory.

    Science.gov (United States)

    Faircloth, D C; Lawrie, S; Letchford, A P; Gabor, C; Wise, P; Whitehead, M; Wood, T; Westall, M; Findlay, D; Perkins, M; Savage, P J; Lee, D A; Pozimski, J K

    2010-02-01

    The aim of the front end test stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a 60 mA Penning Surface Plasma Ion Source, a three solenoid low energy beam transport, a 3 MeV radio frequency quadrupole, a chopper, and a comprehensive suite of diagnostics. This paper details the design and initial performance of the ion source and the laser profile measurement system. Beam current, profile, and emittance measurements are shown for different operating conditions.

  13. ICS logging solution for network-based attacks using Gumistix technology

    Science.gov (United States)

    Otis, Jeremy R.; Berman, Dustin; Butts, Jonathan; Lopez, Juan

    2013-05-01

    Industrial Control Systems (ICS) monitor and control operations associated with the national critical infrastructure (e.g., electric power grid, oil and gas pipelines and water treatment facilities). These systems rely on technologies and architectures that were designed for system reliability and availability. Security associated with ICS was never an inherent concern, primarily due to the protections afforded by network isolation. However, a trend in ICS operations is to migrate to commercial networks via TCP/IP in order to leverage commodity benefits and cost savings. As a result, system vulnerabilities are now exposed to the online community. Indeed, recent research has demonstrated that many exposed ICS devices are being discovered using readily available applications (e.g., ShodanHQ search engine and Google-esque queries). Due to the lack of security and logging capabilities for ICS, most knowledge about attacks are derived from real world incidents after an attack has already been carried out and the damage has been done. This research provides a method for introducing sensors into the ICS environment that collect information about network-based attacks. The sensors are developed using an inexpensive Gumstix platform that can be deployed and incorporated with production systems. Data obtained from the sensors provide insight into attack tactics (e.g., port scans, Nessus scans, Metasploit modules, and zero-day exploits) and characteristics (e.g., attack origin, frequency, and level of persistence). Findings enable security professionals to draw an accurate, real-time awareness of the threats against ICS devices and help shift the security posture from reactionary to preventative.

  14. Practical research of free standing rack. Seismic experiment study on full scale free standing rack

    International Nuclear Information System (INIS)

    Iwasaki, Akihisa; Nekomoto, Yoshitsugu; Morita, Hideyuki; Taniguchi, Katsuhiko; Okuno, Daisaku; Matsuoka, Toshihiro; Chigusa, Naoki

    2015-01-01

    The spent fuel taken out of a plant reactor is temporarily stored in a spent fuel rack. This fuel will often have to be stored in the rack for long periods before it can be moved to a reprocessing facility. Therefore, the spent fuel rack must have a high tolerance against big seismic loads. The free standing spent fuel rack has been developed as the optimal equipment meeting these requirements. It can be placed on the spent fuel pool floor without fixation to any support structure. Response of the free standing rack is reduced by the effect of the water and friction force on the spent fuel pool floor. For nuclear plant safety, it is necessary to understand the free standing rack behavior under earthquake in pools to verify the design of free standing racks and peripheral components. Several tests on a shaking table have been conducted on full-scale one free standing rack in air and in water, and sliding and rocking have been measured. The rack response is very complex and the study necessitates to take into account the sliding, the rocking, the effect of the water and of the arrangement of the fuel assemblies inside. (author)

  15. A test of high-dose verbenone for stand-level protection of lodgepole and whitebark pine from mountain pine beetle (Coleoptera: Curculionidae: Scolytinae) attacks

    Science.gov (United States)

    B. J. Bentz; S. Kegley; K. Gibson; R. Their

    2005-01-01

    The effcacy of verbenone as a stand-level protectant against mountain pine beetle, Dendroctonus ponderosae Hopkins, attacks was tested in lodgepole and whitebark pine stands at five geographically separated sites, including three consecutive years at one site. Forty and 20 high-dose pouches, with a verbenone emission rate up to 50 mg/d per pouch, were spaced in a grid...

  16. Pengaruh Pengungkapan Intellectual Capital (IC dan Economic Value Added (EVA terhadap Harga Saham Perusahaan Manufaktur yang terdaftar di BEI

    Directory of Open Access Journals (Sweden)

    Achmad Fauzi

    2015-07-01

    Full Text Available This study aims at finding out if The Influence of Intellectual Capital (ICand Economic Value Added (EVA on Stock Price of Manufacturing Companies listed on the Indonesia Stock Exchange (BEI in 2012. The hypothesis of this study is : There is Influence of Intellectual Capital (IC and Economic Value Added (EVA on Stock Price of Manufacturing Company listed on the Indonesia Stock Exchange (BEI in 2012. The method used is the author of the survey method with a quantitative approach . This study population is the entire manufacturing companies listed on the Stock Exchange in 2012 his sampling technique is random sampling as many as 36 samples .. Correlation Coefficient significance test ( Test A of 0.512 , indicating that there is a middle relationship between IC and EVA on Stock Price. The results of the coefficient of determination ( R2 Test stated that R2 is 0.262 or 26.2% . This shows that the percentage contribution of the effect of independent variables ( IC and EVA on the dependent variable ( stock price of 26.2 % . Or variations of the independent variables used in the model ( IC and EVA are able to explain 26.2% of variation in the dependent variable ( stock price . While the remaining 73.8 % are influenced or explained by other variables not included in this research model .

  17. Seismic performance of an existing bridge with scoured caisson foundation

    Science.gov (United States)

    Chang, Kuo-Chun; Sung, Yu-Chi; Liu, Kuang-Yen; Wang, Ping-Hsiung; Lee, Zheng-Kuan; Lee, Lu-Sheng; Witarto

    2014-08-01

    This paper presents in-situ seismic performance tests of a bridge before its demolition due to accumulated scouring problem. The tests were conducted on three single columns and one caisson-type foundation. The three single columns were 1.8 m in diameter, reinforced by 30-D32 longitudinal reinforcements and laterally hooped by D16 reinforcements with spacing of 20 cm. The column height is 9.54 m, 10.59 m and 10.37 m for Column P2, P3, and P4, respectively. Column P2 had no exposed foundation and was subjected to pseudo-dynamic tests with peak ground acceleration of 0.32 g first, followed by one cyclic loading test. Column P3 was the benchmark specimen with exposed length of 1.2 m on its foundation. The exposed length for Column P4 was excavated to 4 m, approximately 1/3 of the foundation length, to study the effect of the scouring problem to the column performance. Both Column P3 and Column P4 were subjected to cyclic loading tests. Based on the test results, due to the large dimension of the caisson foundation and the well graded gravel soil type that provided large lateral resistance, the seismic performance among the three columns had only minor differences. Lateral push tests were also conducted on the caisson foundation at Column P5. The caisson was 12 m long and had circular cross-sections whose diameters were 5 m in the upper portion and 4 m in the lower portion. An analytical model to simulate the test results was developed in the OpenSees platform. The analytical model comprised nonlinear flexural elements as well as nonlinear soil springs. The analytical results closely followed the experimental test results. A parametric study to predict the behavior of the bridge column with different ground motions and different levels of scouring on the foundation are also discussed.

  18. Preliminary optimal configuration on free standing hybrid riser

    Directory of Open Access Journals (Sweden)

    Kyoung-Su Kim

    2018-05-01

    Full Text Available Free Standing Hybrid Riser (FSHR is comprised of vertical steel risers and Flexible Jumpers (FJ. They are jointly connected to a submerged Buoyancy Can (BC. There are several factors that have influence on the behavior of FSHR such as the span distance between an offshore platform and a foundation, BC up-lift force, BC submerged location and FJ length.An optimization method through a parametric study is presented. Firstly, descriptions for the overall arrangement and characteristics of FSHR are introduced. Secondly, a flowchart for optimization of FSHR is suggested. Following that, it is described how to select reasonable ranges for a parametric study and determine each of optimal configuration options. Lastly, numerical analysis based on this procedure is performed through a case study. In conclusion, the relation among those parameters is analyzed and non-dimensional parametric ranges on optimal arrangements are suggested. Additionally, strength analysis is performed with variation in the configuration. Keywords: Free standing hybrid riser, Hybrid riser system, Buoyancy can, Flexible jumper, Deepwater, Multi-body dynamics

  19. Association of unipedal standing time and bone mineral density in community-dwelling Japanese women.

    Science.gov (United States)

    Sakai, A; Toba, N; Takeda, M; Suzuki, M; Abe, Y; Aoyagi, K; Nakamura, T

    2009-05-01

    Bone mineral density (BMD) and physical performance of the lower extremities decrease with age. In community-dwelling Japanese women, unipedal standing time, timed up and go test, and age are associated with BMD while in women aged 70 years and over, unipedal standing time is associated with BMD. The aim of this study was to clarify whether unipedal standing time is significantly associated with BMD in community-dwelling women. The subjects were 90 community-dwelling Japanese women aged 54.7 years. BMD of the second metacarpal bone was measured by computed X-ray densitometry. We measured unipedal standing time as well as timed up and go test to assess physical performance of the lower extremities. Unipedal standing time decreased with increased age. Timed up and go test significantly correlated with age. Low BMD was significantly associated with old age, short unipedal standing time, and long timed up and go test. Stepwise regression analysis revealed that age, unipedal standing time, and timed up and go test were significant factors associated with BMD. In 21 participants aged 70 years and over, body weight and unipedal standing time, but not age, were significantly associated with BMD. BMD and physical performance of the lower extremities decrease with older age. Unipedal standing time, timed up and go test, and age are associated with BMD in community-dwelling Japanese women. In women aged 70 years and over, unipedal standing time is significantly associated with BMD.

  20. Development of grouped icEEG for the study of cognitive processing

    Directory of Open Access Journals (Sweden)

    Cihan Mehmet Kadipasaoglu

    2015-07-01

    Full Text Available Invasive intracranial EEG (icEEG offers a unique opportunity to study human cognitive networks at an unmatched spatiotemporal resolution. To date, the contributions of icEEG have been limited to the individual-level analyses or cohorts whose data are not integrated in any way. Here we discuss how grouped approaches to icEEG overcome challenges related to sparse-sampling, correct for individual variations in response and provide statistically valid models of brain activity in a population. By the generation of whole-brain activity maps, grouped icEEG enables the study of intra and interregional dynamics between distributed cortical substrates exhibiting task-dependent activity. In this fashion, grouped icEEG analyses can provide significant advances in understanding the mechanisms by which cortical networks give rise to cognitive functions.

  1. Boosting Belligerence: How the July 7, 2005, London Bombings Affected Liberals' Moral Foundations and Prejudice.

    Science.gov (United States)

    Van de Vyver, Julie; Houston, Diane M; Abrams, Dominic; Vasiljevic, Milica

    2016-02-01

    Major terrorist events, such as the recent attacks in Ankara, Sinai, and Paris, can have profound effects on a nation's values, attitudes, and prejudices. Yet psychological evidence testing the impact of such events via data collected immediately before and after an attack is understandably rare. In the present research, we tested the independent and joint effects of threat (the July 7, 2005, London bombings) and political ideology on endorsement of moral foundations and prejudices among two nationally representative samples (combined N = 2,031) about 6 weeks before and 1 month after the London bombings. After the bombings, there was greater endorsement of the in-group foundation, lower endorsement of the fairness-reciprocity foundation, and stronger prejudices toward Muslims and immigrants. The differences in both the endorsement of the foundations and the prejudices were larger among people with a liberal orientation than among those with a conservative orientation. Furthermore, the changes in endorsement of moral foundations among liberals explained their increases in prejudice. The results highlight the value of psychological theory and research for understanding societal changes in attitudes and prejudices after major terrorist events. © The Author(s) 2015.

  2. Extreme low-power mixed signal IC design

    CERN Document Server

    Tajalli, Armin

    2010-01-01

    This book describes a completely novel class of techniques for designing ultra-low-power integrated circuits (ICs). In many applications such as battery operated systems and battery-less (energy-scavenging) systems, power dissipation is a critical parameter. As a result, there is a growing demand for reducing the power (energy) consumption in ICs to extremely low levels, not achievable by using classical ""subthreshold CMOS"" techniques. This book introduces a new family of ""subthreshold circuits"" called ""source-coupled circuits"". This family of circuits can be used for implementing digita

  3. Design Developing of IC- Model Using VHDL

    International Nuclear Information System (INIS)

    Inzar-Anas

    2005-01-01

    In present, the electronic design required to become simple, small and flexible. The physical dimension of IC and number of pin can be significantly reduced while the flexibility and compatibility of IC was not change. Implementation of VHDL(VHSIC Hardware Description Language) seem as a great progress in the design of digital circuit. By using this language designing of model can be more simple, flexible and efficient. This paper was purposed to introduce VHDL and its features. Sample in modeling to illustrate the advantage of VHDL will also be described. (author)

  4. Sensitivity Study on Availability of I&C Components Using Bayesian Network

    Directory of Open Access Journals (Sweden)

    Rahman Khalil Ur

    2013-01-01

    Full Text Available The objective of this study is to find out the impact of instrumentation and control (I&C components on the availability of I&C systems in terms of sensitivity analysis using Bayesian network. The analysis has been performed on I&C architecture of reactor protection system. The analysis results would be applied to develop I&C architecture which will meet the desire reliability features and save cost. RPS architecture unavailability P(x=0 and availability P(x=1 were estimated to 6.1276E-05 and 9.9994E-01 for failure (0 and perfect (1 states, respectively. The impact of I&C components on overall system risk has been studied in terms of risk achievement worth (RAW and risk reduction worth (RRW. It is found that circuit breaker failure (TCB, bi-stable processor (BP, sensor transmitter (TR, and pressure transmitter (PT have high impact on risk. The study concludes and recommends that circuit breaker bi-stable processor should be given more consideration while designing I&C architecture.

  5. Post-test analysis of PIPER-ONE PO-IC-2 experiment by RELAP5/MOD3 codes

    International Nuclear Information System (INIS)

    Bovalini, R.; D'Auria, F.; Galassi, G.M.; Mazzini, M.

    1996-11-01

    RELAP5/MOD3.1 was applied to the PO-IC-2 experiment performed in PIPER-ONE facility, which has been modified to reproduce typical isolation condenser thermal-hydraulic conditions. RELAP5 is a well known code widely used at the University of Pisa during the past seven years. RELAP5/MOD3.1 was the latest version of the code made available by the Idaho National Engineering Laboratory at the time of the reported study. PIPER-ONE is an experimental facility simulating a General Electric BWR-6 with volume and height scaling ratios of 1/2,200 and 1./1, respectively. In the frame of the present activity a once-through heat exchanger immersed in a pool of ambient temperature water, installed approximately 10 m above the core, was utilized to reproduce qualitatively the phenomenologies expected for the Isolation Condenser in the simplified BWR (SBWR). The PO-IC-2 experiment is the flood up of the PO-SD-8 and has been designed to solve some of the problems encountered in the analysis of the PO-SD-8 experiment. A very wide analysis is presented hereafter including the use of different code versions

  6. Novel automatic phase lock determination for superconducting cavity tests at vertical test stand at RRCAT

    International Nuclear Information System (INIS)

    Singh, Kunver Adarsh Pratap; Mohania, Praveen; Rajput, Vikas; Baxy, Deodatta; Shrivastava, Purushottam

    2015-01-01

    RRCAT has developed a Vertical Test Stand (VTS) which is used to test the Nb superconducting cavities under cryogenic conditions. In the VTS, RF cavity is characterized for its quality factor variation vs the accelerating gradient. The RF system is an essential part of the VTS which is required to provide stable RF power to the cavity in terms of amplitude, frequency and phase. RF system of VTS consists of several modules including the LLRF system. The LLRF system consists of the 'Frequency Control Module' which controls the input frequency to the SCRF cavity. Due to high quality factor, bandwidth of the cavity is less than 1 Hz. Even slight mechanical vibrations (microphonics) causes change in cavity resonance frequency resulting in total reflection of incident power. A PLL based frequency tracking module has been used to track the resonant frequency of RF cavity. This module changes RF source frequency according to change in Cavity resonance frequency. A novel method using a LabView based computer program has been developed which changes the phase of input RF signal using IQ modulator and monitors the transmitted power, incident and reflected power. The program plots the graph between phase and ratio of transmitted power to incident/reflected power and gives optimum locking phase for operation which has resulted in significant saving in the overall process time for the tests of the cavities in VTS. (author)

  7. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem.

    Science.gov (United States)

    Muller, A; Pontonnier, C; Dumont, G

    2018-02-01

    The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions - two polynomial criteria and a min/max criterion - were tested on a planar musculoskeletal model. The MusIC method provides a computation frequency approximately 10 times higher compared to a classical optimization problem with a relative mean error of 4% on cost function evaluation.

  8. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  9. Prion seeding activities of mouse scrapie strains with divergent PrPSc protease sensitivities and amyloid plaque content using RT-QuIC and eQuIC.

    Directory of Open Access Journals (Sweden)

    Sarah Vascellari

    Full Text Available Different transmissible spongiform encephalopathy (TSE-associated forms of prion protein (e.g. PrP(Sc can vary markedly in ultrastructure and biochemical characteristics, but each is propagated in the host. PrP(Sc propagation involves conversion from its normal isoform, PrP(C, by a seeded or templated polymerization mechanism. Such a mechanism is also the basis of the RT-QuIC and eQuIC prion assays which use recombinant PrP (rPrP(Sen as a substrate. These ultrasensitive detection assays have been developed for TSE prions of several host species and sample tissues, but not for murine models which are central to TSE pathogenesis research. Here we have adapted RT-QuIC and eQuIC to various murine prions and evaluated how seeding activity depends on glycophosphatidylinositol (GPI anchoring and the abundance of amyloid plaques and protease-resistant PrP(Sc (PrP(Res. Scrapie brain dilutions up to 10(-8 and 10(-13 were detected by RT-QuIC and eQuIC, respectively. Comparisons of scrapie-affected wild-type mice and transgenic mice expressing GPI anchorless PrP showed that, although similar concentrations of seeding activity accumulated in brain, the heavily amyloid-laden anchorless mouse tissue seeded more rapid reactions. Next we compared seeding activities in the brains of mice with similar infectivity titers, but widely divergent PrP(Res levels. For this purpose we compared the 263K and 139A scrapie strains in transgenic mice expressing P101L PrP(C. Although the brains of 263K-affected mice had little immunoblot-detectable PrP(Res, RT-QuIC indicated that seeding activity was comparable to that associated with a high-PrP(Res strain, 139A. Thus, in this comparison, RT-QuIC seeding activity correlated more closely with infectivity than with PrP(Res levels. We also found that eQuIC, which incorporates a PrP(Sc immunoprecipitation step, detected seeding activity in plasma from wild-type and anchorless PrP transgenic mice inoculated with 22L, 79A and/or RML

  10. A sum-over-paths algorithm for third-order impulse-response moment extraction within RC IC-interconnect networks

    Science.gov (United States)

    Wojcik, E. A.; Ni, D.; Lam, T. M.; Le Coz, Y. L.

    2015-07-01

    We have created the first stochastic SoP (Sum-over-Paths) algorithm to extract third-order impulse-response (IR) moment within RC IC interconnects. It employs a newly discovered Feynman SoP Postulate. Importantly, our algorithm maintains computational efficiency and full parallelism. Our approach begins with generation of s-domain nodal-voltage equations. We then perform a Taylor-series expansion of the circuit transfer function. These expansions yield transition diagrams involving mathematical coupling constants, or weight factors, in integral powers of complex frequency s. Our SoP Postulate enables stochastic evaluation of path sums within the circuit transition diagram to order s3-corresponding to the order of IR moment (m3) we seek here. We furnish, for the first time, an informal algebraic proof independently validating our SoP Postulate and algorithm. We list, as well, detailed procedural steps, suitable for coding, that define an efficient stochastic algorithm for m3 IR extraction. Origins of the algorithm's statistical "capacitor-number cubed" correction and "double-counting" weight factors are explained, for completeness. Our algorithm was coded and successfully tested against exact analytical solutions for 3-, 5-, and 10-stage RC lines. We achieved better than 0.65% 1-σ error convergence, after only 10K statistical samples, in less than 1 s of 2-GHz Pentium® execution time. These results continue to suggest that stochastic SoP algorithms may find useful application in circuit analysis of massively coupled networks, such as those encountered in high-end digital IC-interconnect CAD.

  11. ON-LINE MONITORING OF I&C TRANSMITTERS AND SENSORS FOR CALIBRATION VERIFICATION AND RESPONSE TIME TESTING WAS SUCCESSFULLY IMPLEMENTED AT ATR

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, Phillip A.; O' Hagan, Ryan; Shumaker, Brent; Hashemian, H. M.

    2017-03-01

    The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.

  12. System reduction for nanoscale IC design

    CERN Document Server

    2017-01-01

    This book describes the computational challenges posed by the progression toward nanoscale electronic devices and increasingly short design cycles in the microelectronics industry, and proposes methods of model reduction which facilitate circuit and device simulation for specific tasks in the design cycle. The goal is to develop and compare methods for system reduction in the design of high dimensional nanoelectronic ICs, and to test these methods in the practice of semiconductor development. Six chapters describe the challenges for numerical simulation of nanoelectronic circuits and suggest model reduction methods for constituting equations. These include linear and nonlinear differential equations tailored to circuit equations and drift diffusion equations for semiconductor devices. The performance of these methods is illustrated with numerical experiments using real-world data. Readers will benefit from an up-to-date overview of the latest model reduction methods in computational nanoelectronics.

  13. Seismic isolation of two dimensional periodic foundations

    International Nuclear Information System (INIS)

    Yan, Y.; Mo, Y. L.; Laskar, A.; Cheng, Z.; Shi, Z.; Menq, F.; Tang, Y.

    2014-01-01

    Phononic crystal is now used to control acoustic waves. When the crystal goes to a larger scale, it is called periodic structure. The band gaps of the periodic structure can be reduced to range from 0.5 Hz to 50 Hz. Therefore, the periodic structure has potential applications in seismic wave reflection. In civil engineering, the periodic structure can be served as the foundation of upper structure. This type of foundation consisting of periodic structure is called periodic foundation. When the frequency of seismic waves falls into the band gaps of the periodic foundation, the seismic wave can be blocked. Field experiments of a scaled two dimensional (2D) periodic foundation with an upper structure were conducted to verify the band gap effects. Test results showed the 2D periodic foundation can effectively reduce the response of the upper structure for excitations with frequencies within the frequency band gaps. When the experimental and the finite element analysis results are compared, they agree well with each other, indicating that 2D periodic foundation is a feasible way of reducing seismic vibrations.

  14. F-15B ACTIVE with thrust vectoring nozzles on test stand at sunrise

    Science.gov (United States)

    1995-01-01

    This November 13, 1995, photograph of the F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) at NASA's Dryden Flight Research Center, Edwards, California, shows the aircraft on a test stand at sunrise. Not shown in this photograph are the aircraft's two new Pratt & Whitney nozzles that can turn up to 20 degrees in any direction. These nozzles give the aircraft thrust control in the pitch (up and down) and yaw (left and right) directions. This will reduce drag and increase fuel economy or range as compared with conventional aerodynamic controls, which increase the retarding forces (drag) acting upon the aircraft. These tests could result in significant performance increases for military and commercial aircraft. The research program is the product of a collaborative effort by NASA, the Air Force's Wright Laboratory, Pratt & Whitney, and McDonnell Douglas Aerospace. The aircraft was originally built as an F-15B (Serial #71-0290).

  15. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    Science.gov (United States)

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  16. Reliability and fatigue characteristics of a standing hip isometric endurance protocol.

    Science.gov (United States)

    Mutchler, Jessica A; Weinhandl, Joshua T; Hoch, Matthew C; Van Lunen, Bonnie L

    2015-08-01

    Muscle fatigue is a common consideration when evaluating and rehabilitating athletic injuries. The presence of muscular fatigue has been previously determined by quantifying median frequency (MF) through a power spectral analysis on EMG signals collected throughout an endurance task. Research has not yet determined if a prolonged isometric test in a standing position generates muscular fatigue of the hip. The purpose of this study was to determine the reliability and fatigue characteristics of a standing hip isometric endurance test. Twenty healthy participants completed one 60-s Maximum Voluntary Isometric Contraction of standing hip flexion, extension, adduction, and abduction. MF of the participants' dominant limb rectus femoris (RF), biceps femoris (BF), gluteus maximus (GMax), gluteus medius (GMed) and adductor longus (ADD) was determined via surface electromyography during two sessions, 30-min apart. Reliability values (ICC2,1) were moderate-to-excellent for all time intervals of each action (FlexionRF: >0.80; ExtensionBF: >0.89; ExtensionGMax: >0.60; AdductionADD: >0.78; AbductionGMed: >0.60) and MF significantly decreased over time for all actions. Results suggest the endurance test is a reliable technique to generate muscular fatigue for hip flexion, extension, adduction and abduction. It can be used as a time efficient fatigue protocol specific to the RF, BF, GMax, ADD and GMed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Children's Brain Tumor Foundation

    Science.gov (United States)

    ... 2 Family Donate Volunteer Justin's Hope Fund Children’s Brain Tumor Foundation, A non-profit organization, was founded ... and the long term outlook for children with brain and spinal cord tumors through research, support, education, ...

  18. The 1-min sit-to-stand test in cystic fibrosis - Insights into cardiorespiratory responses.

    Science.gov (United States)

    Radtke, Thomas; Hebestreit, Helge; Puhan, Milo A; Kriemler, Susi

    2017-11-01

    We aimed to characterize the cardiopulmonary response during a 1-min sit-to-stand (STS) test and compare peak exercise cardiorespiratory variables to a maximal cardiopulmonary exercise test (CPET) in cystic fibrosis (CF). We further aimed to assess the validity of the STS power index (Power STS ) as a measure of exercise capacity. Fifteen adult CF patients performed spirometry, CPET and the 1-min STS test with respiratory gas analysis. Peak-exercise cardiorespiratory variables during the 1-min STS test correlated strongly (r=0.69-0.98) with those measured during the CPET. Oxygen uptake, carbon dioxide production, heart rate, ventilation, and tidal volume at peak exercise were 24%, 26%, 9%, 10% and 21% lower in the 1-min STS test, while respiratory frequencies were 14% higher. Power STS showed strong to very strong correlations with CPET-derived absolute peak oxygen uptake and maximal workload. The 1-min STS test elicits a substantial but lower cardiorespiratory response compared to a maximal cycle ergometry CPET. While Power STS and STS repetitions are both valid outcome measures of functional capacity, STS repetitions are clinically more practical. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  19. Catalog of Realizations for DXCCII using Commercially Available ICs and Applications

    Directory of Open Access Journals (Sweden)

    S. Maheshwari

    2012-04-01

    Full Text Available This paper presents fifteen distinct practical realizations for dual-X second generation current conveyor (DXCCII using commercially available integrated circuits. Detailed comparisons and results are presented to verify the utility of proposed realizations. The catalog of proposed realizations is a first attempt and is expected to be useful for testing newly developed circuits based on dual-X second generation current conveyor. Each of the first fourteen proposed realizations uses four ICs. One three IC based implementation is further given making the total count fifteen. Some additional features are also explored which further enhance the versatility of DXCCII. The paper further presents a novel and compact quadrature oscillator to verify the applicability of the proposed realizations. Single resistance control of the frequency of oscillation is also demonstrated by employing the new gain-variable DXCCII. Experimental results are also included along with simulation results to validate the proposed theory and its practical significance.

  20. Commercialization of an S-band standing-wave electron accelerator for industrial applications

    Science.gov (United States)

    Moon, Jin-Hyeok; Kwak, Gyeong-Il; Han, Jae-Ik; Lee, Gyu-Baek; Jeon, Seong-Hwan; Kim, Jae-Young; Hwang, Cheol-Bin; Lee, Gi-Yong; Kim, Young-Man; Park, Sung-Ju

    2016-09-01

    An electron accelerator system has been developed for use in industrial, as well as possible medical, applications. Based on our experiences achieved during prototype system development and various electron beam acceleration tests, we have built a stable and compact system for sales purposes. We have integrated a self-developed accelerating cavity, an E-gun pulse driver, a radio-frequency (RF) power system, a vacuum system, a cooling system, etc. into a frame with a size of 1800 × 1000 × 1500 mm3. The accelerating structure is a side-coupled standing-wave type operating in the π/2 mode (tuned to~3 GHz). The RF power is provided by using a magnetron driven by a solid-state modulator. The electron gun is a triode type with a dispenser cathode (diameter of 11 mm). The system is capable of delivering a maximum 900-W average electron beam power with tight focusing at the target. Until now, we have performed various electron beam tests and X-ray beam tests after having built the system, have completed the beam assessment for commercializations, and have been preparing full-fledged sales activity. This article reports on our system development processes and on some of our early test results for commercializations.

  1. RF-Breakdown kicks at the CTF3 two-beam test stand

    CERN Document Server

    Palaia, Andrea; Muranaka, Tomoko; Ruber, Roger; Ziemann, V; Farabolini, W

    2012-01-01

    The measurement of the effects of RF-breakdown on the beam in CLIC prototype accelerator structures is one of the key aspects of the CLIC two-beam acceleration scheme being addressed at the Two-beam Test Stand (TBTS) at CTF3. RF-breakdown can randomly cause energy loss and transverse kicks to the beam. Transverse kicks have been measured by means of a screen intercepting the beam after the accelerator structure. In correspondence of a RFbreakdown we detect a double beam spot which we interpret as a sudden change of the beam trajectory within a single beam pulse. To time-resolve such effect, the TBTS has been equipped with five inductive Beam Position Monitors (BPMs) and a spectrometer line to measure both relative changes of the beam trajectory and energy losses. Here we discuss the methodology used and we present the latest results of such measurements

  2. System integration and performance of the EUV engineering test stand

    International Nuclear Information System (INIS)

    Tichenor, Daniel A.; Ray-Chaudhuri, Avijit K.; Replogle, William C.; Stulen, Richard H.; Kubiak, Glenn D.; Rockett, Paul D.; Klebanoff, Leonard E.; Jefferson, Karen L.; Leung, Alvin H.; Wronosky, John B.; Hale, Layton C.; Chapman, Henry N.; Taylor, John S.; Folta, James A.; Montcalm, Claude; Soufli, Regina; Spiller, Eberhard; Blaedel, Kenneth; Sommargren, Gary E.; Sweeney, Donald W.; Naulleau, Patrick; Goldberg, Kenneth A.; Gullikson, Eric M.; Bokor, Jeffrey; Batson, Phillip J.; Attwood, David T.; Jackson, Keith H.; Hector, Scott D.; Gwyn, Charles W.; Yan, Pei-Yang; Yan, P.

    2001-01-01

    The Engineering Test Stand (ETS) is a developmental lithography tool designed to demonstrate full-field EUV imaging and provide data for commercial-tool development. In the first phase of integration, currently in progress, the ETS is configured using a developmental projection system, while fabrication of an improved projection system proceeds in parallel. The optics in the second projection system have been fabricated to tighter specifications for improved resolution and reduced flare. The projection system is a 4-mirror, 4x-reduction, ring-field design having a numeral aperture of 0.1, which supports 70 nm resolution at a k 1 of 0.52. The illuminator produces 13.4 nm radiation from a laser-produced plasma, directs the radiation onto an arc-shaped field of view, and provides an effective fill factor at the pupil plane of 0.7. The ETS is designed for full-field images in step-and-scan mode using vacuum-compatible, magnetically levitated, scanning stages. This paper describes system performance observed during the first phase of integration, including static resist images of 100 nm isolated and dense features

  3. Mismatch and noise in modern IC processes

    CERN Document Server

    Marshall, Andrew

    2009-01-01

    Component variability, mismatch, and various noise effects are major contributors to design limitations in most modern IC processes. Mismatch and Noise in Modern IC Processes examines these related effects and how they affect the building block circuits of modern integrated circuits, from the perspective of a circuit designer.Variability usually refers to a large scale variation that can occur on a wafer to wafer and lot to lot basis, and over long distances on a wafer. This phenomenon is well understood and the effects of variability are included in most integrated circuit design with the use

  4. 30 CFR 57.22209 - Auxiliary fans (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary fans (I-C mines). 57.22209 Section 57... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22209 Auxiliary fans (I-C mines). Electric auxiliary fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18...

  5. Identification of signals that facilitate isoform specific nucleolar localization of myosin IC

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, Ryan S.; Ihnatovych, Ivanna; Yunus, Sharifah Z.S.A.; Domaradzki, Tera [Department of Physiology and Biophysics, University at Buffalo—State University of New York, Buffalo, NY (United States); Hofmann, Wilma A., E-mail: whofmann@buffalo.edu [Department of Physiology and Biophysics, University at Buffalo—State University of New York, Buffalo, NY (United States)

    2013-05-01

    Myosin IC is a single headed member of the myosin superfamily that localizes to the cytoplasm and the nucleus, where it is involved in transcription by RNA polymerases I and II, intranuclear transport, and nuclear export. In mammalian cells, three isoforms of myosin IC are expressed that differ only in the addition of short isoform-specific N-terminal peptides. Despite the high sequence homology, the isoforms show differences in cellular distribution, in localization to nuclear substructures, and in their interaction with nuclear proteins through yet unknown mechanisms. In this study, we used EGFP-fusion constructs that express truncated or mutated versions of myosin IC isoforms to detect regions that are involved in isoform-specific localization. We identified two nucleolar localization signals (NoLS). One NoLS is located in the myosin IC isoform B specific N-terminal peptide, the second NoLS is located upstream of the neck region within the head domain. We demonstrate that both NoLS are functional and necessary for nucleolar localization of specifically myosin IC isoform B. Our data provide a first mechanistic explanation for the observed functional differences between the myosin IC isoforms and are an important step toward our understanding of the underlying mechanisms that regulate the various and distinct functions of myosin IC isoforms. - Highlights: ► Two NoLS have been identified in the myosin IC isoform B sequence. ► Both NoLS are necessary for myosin IC isoform B specific nucleolar localization. ► First mechanistic explanation of functional differences between the isoforms.

  6. Prototype bucket foundation for wind turbines

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten

    The first full scale prototype bucket foundation for wind turbines has been installed in October 2002 at Aalborg University offshore test facility in Frederikshavn, Denmark. The suction caisson and the wind turbine have been equipped with an online monitoring system, consisting of 15 accelerometers...... and a real-time data-acquisition system. The report concerns the in service performance of the wind turbine, with focus on estimation of the natural frequencies of the structure/foundation. The natural frequencies are initially estimated by means of experimental Output-only Modal analysis. The experimental...... estimates are then compared with numerical simulations of the suction caisson foundation and the wind turbine. The numerical model consists of a finite element section for the wind turbine tower and nacelle. The soil-structure interaction of the soil-foundation section is modelled by lumped-parameter models...

  7. StandsSIM-MD: a Management Driven forest SIMulator

    Energy Technology Data Exchange (ETDEWEB)

    Barreiro, S.; Rua, J.; Tomé, M.

    2016-07-01

    Aim of the study. The existing stand level forest simulators available in Portugal were not developed with the aim of including up-to-date model versions and were limited in terms of accounting for forest management. The simulators’ platform, sIMfLOR was recently created to implement different growth models with a common philosophy. The objective was developing one easily-updatable, user-friendly, forest management and climate change sensitive simulator capable of projecting growth for the main tree species in Portugal. Area of the study: Portugal. Material and methods: The new simulator was programmed in a modular form consisting of several modules. The growth module integrates different forest growth and yield models (empirical and process-based) for the main wood production tree species in Portugal (eucalypt, umbrella and maritime pines); whereas the management module drives the growth projections along the planning horizon according to a range of forest management approaches and climate (at present only available for eucalypt). Main results: The main result is the StandsSIM-MD Management Driven simulator that overcomes the limitations of the existing stand level simulators. It is a step forward when compared to the models currently available in the sIMfLOR platform covering more tree species, stand structures and stand compositions. It is focused on end-users and it is based on similar concepts regarding the generation of required inputs and generated outputs. Research highlights: Forest Management Driven simulations approach. Multiple Prescriptions-Per-Stand functionality. StandsSIM-MD can be used to support landowners decisions on stand forest management. StandsSIM-MD simulations at regional level can be combined with optimization routines. (Author)

  8. Testing as social practice

    DEFF Research Database (Denmark)

    Kousholt, Kristine

    2016-01-01

    In this article, the author challenges the implicit assumptions of tests as a neutral tool for measuring the individual’s learning achievement. Instead, testing is explored as a social practice which becomes part of children’s conduct of everyday life. The theoretical foundation for the analysis...

  9. Study on Mine Emergency Mechanism based on TARP and ICS

    Science.gov (United States)

    Xi, Jian; Wu, Zongzhi

    2018-01-01

    By analyzing the experiences and practices of mine emergency in China and abroad, especially the United States and Australia, normative principle, risk management principle and adaptability principle of constructing mine emergency mechanism based on Trigger Action Response Plans (TARP) and Incident Command System (ICS) are summarized. Classification method, framework, flow and subject of TARP and ICS which are suitable for the actual situation of domestic mine emergency are proposed. The system dynamics model of TARP and ICS is established. The parameters such as evacuation ratio, response rate, per capita emergency capability and entry rate of rescuers are set up. By simulating the operation process of TARP and ICS, the impact of these parameters on the emergency process are analyzed, which could provide a reference and basis for building emergency capacity, formulating emergency plans and setting up action plans in the emergency process.

  10. Prometheus Reactor I&C Software Development Methodology, for Action

    Energy Technology Data Exchange (ETDEWEB)

    T. Hamilton

    2005-07-30

    The purpose of this letter is to submit the Reactor Instrumentation and Control (I&C) software life cycle, development methodology, and programming language selections and rationale for project Prometheus to NR for approval. This letter also provides the draft Reactor I&C Software Development Process Manual and Reactor Module Software Development Plan to NR for information.

  11. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong, E-mail: amosrxd@163.com; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun [Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-108, Mianyang, Sichuan 621999 (China); Zhou, Xiu-Wen; Yang, Yi [Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-987, Mianyang, Sichuan 621999 (China)

    2015-07-15

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ∼10 MA, 70 ns rise-time (10%–90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132–300 tungsten wires with 5–10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (∼50 TW) and total radiated energy (∼500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  12. Minutes of Proceedings and Evidence of the Standing Committee on External Affairs and International Trade Respecting: Pursuant to Standing Order 108(2), consideration of nuclear dumping and testing in the Russian Arctic

    International Nuclear Information System (INIS)

    1993-01-01

    The Standing Committee on External Affairs and International Trade met to consider the nuclear dumping and testing in the Russian Arctic. Canada is concerned about the environmental effects of the radioactive waste to the marine environment. The safe dismantlement of nuclear weapons or reactors is of major concern

  13. Minutes of Proceedings and Evidence of the Standing Committee on External Affairs and International Trade Respecting: Pursuant to Standing Order 108(2), consideration of nuclear dumping and testing in the Russian Arctic

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Standing Committee on External Affairs and International Trade met to consider the nuclear dumping and testing in the Russian Arctic. Canada is concerned about the environmental effects of the radioactive waste to the marine environment. The safe dismantlement of nuclear weapons or reactors is of major concern.

  14. Building on a solid foundation: SAR and QSAR as a fundamental strategy to reduce animal testing.

    Science.gov (United States)

    Sullivan, K M; Manuppello, J R; Willett, C E

    2014-01-01

    The development of more efficient, ethical, and effective means of assessing the effects of chemicals on human health and the environment was a lifetime goal of Gilman Veith. His work has provided the foundation for the use of chemical structure for informing toxicological assessment by regulatory agencies the world over. Veith's scientific work influenced the early development of the SAR models in use today at the US Environmental Protection Agency. He was the driving force behind the Organisation for Economic Co-operation and Development QSAR Toolbox. Veith was one of a few early pioneers whose vision led to the linkage of chemical structure and biological activity as a means of predicting adverse apical outcomes (known as a mode of action, or an adverse outcome pathway approach), and he understood at an early stage the power that could be harnessed when combining computational and mechanistic biological approaches as a means of avoiding animal testing. Through the International QSAR Foundation he organized like-minded experts to develop non-animal methods and frameworks for the assessment of chemical hazard and risk for the benefit of public and environmental health. Avoiding animal testing was Gil's passion, and his work helped to initiate the paradigm shift in toxicology that is now rendering this feasible.

  15. Insuficiência cardíaca: comparação entre o teste de caminhada de seis minutos e o teste cardiopulmonar

    Directory of Open Access Journals (Sweden)

    Eduardo Elias Vieira de Carvalho

    2011-07-01

    Full Text Available FUNDAMENTO: A insuficiência cardíaca crônica (IC é uma síndrome complexa caracterizada pela redução do débito cardíaco em relação às necessidades metabólicas do organismo, bem como alterações metabólicas e do eixo neuro-hormonal. Sintomas como fadiga muscular e dispneia são notórios e os testes de esforço são amplamente utilizados para a avaliação da capacidade funcional, prognóstico e eficácia das intervenções terapêuticas nessa síndrome. OBJETIVO: Avaliar a reprodutibilidade do teste de caminhada de seis minutos (TC6' em pacientes com IC e correlacionar a magnitude das variáveis atingidas no pico do esforço do TC6' com as de um teste cardiopulmonar (TCP. MÉTODOS: Foram estudados 16 pacientes (12 homens e 4 mulheres com diagnóstico de IC CF I-II (NYHA. Os voluntários foram submetidos a dois testes TC6' (TC6'1 e TC6'2 com intervalo de 30 minutos entre eles; posteriormente realizaram um TCP máximo. RESULTADOS: Todas as variáveis obtidas nos dois TC6' mostraram-se significantes, com altas correlações: distância percorrida (DP (r = 0,93; p < 0,0001, frequência cardíaca (FC (r = 0,89; p < 0,0001, consumo de oxigênio (VO2 (r = 0,93; p < 0,0001 e escala de percepção de esforço (r = 0,85; p < 0,0001. Por sua vez, todas as variáveis analisadas no TC6' mostraram correlações moderadas e significantes com as variáveis obtidas no TCP, a saber: FC pico (r = 0,66; p = 0,005; VO2 (r = 0,57; p = 0,02 e VO2 no TCP e DP no TC6'2 (r = 0,70; p = 0,002. CONCLUSÃO: O TC6' foi reprodutível nesse grupo de pacientes com IC (NYHA - I-II e se correlacionou com o TCP. Sendo assim, apresenta-se como ferramenta de avaliação fidedigna, constituindo-se numa alternativa adequada, segura e de baixo custo para a prescrição de exercícios físicos aeróbicos em pacientes com IC.

  16. Effective shunt impedance comparison between s-band standing wave accelerators with on-axis and off-axis couplers

    International Nuclear Information System (INIS)

    Schriber, S.O.; Funk, L.W.; Hutcheon, R.M.

    1976-01-01

    The effective shunt impedances of a side-coupled S-band standing wave accelerating structure and a structure employing on-axis couplers have been compared by measuring the energy of accelerated electrons. Criteria for choosing an on-axis coupled structure compared to side-coupled and ''disk and washer'' accelerating structures are given. (author)

  17. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  18. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  19. Releasing of Sputtered Au Film by Dissolving Sacrificial Layer and Its Self-Standing on Perforated Substrate

    Science.gov (United States)

    Miyamoto, Yu; Fujii, Yuma; Yamano, Masafumi; Harigai, Toru; Suda, Yoshiyuki; Takikawa, Hirofumi; Nishiuchi, Mamiko; Sakaki, Hironao; Kondo, Kiminori

    2015-09-01

    Free-standing thin films such as diamond-like carbon (DLC) and gold (Au) have been attracted increasing interests as film targets used in the laser-driven ion acceleration experiment. One of the methods to make the free-standing thin film is to use a soluble sacrifice layer. In this study, the fabrication technique of self-standing Au thin film is presented. Gelatin, oblate, silk fibroin, and NaCl were examined as a. Au thin films were deposited by DC plasma sputtering on sacrifice layers. The gelatin and oblate were used as the sacrificial layer and the supporting substrate. Silk fibroin was coated on glass substrates by a spin coater. The NaCl sacrificial layers were deposited on flat Si substrates by the vacuum vapor deposition system. Sputtered Au thin films were released by immersing the substrates in purified water. Self-standing Au thin films were fabricated by scooping up the released Au thin film on a perforated substrate. The highest quality of the self-standing Au thin film was achieved by using NaCl sacrificial layer. This work was supported by JSPS KAKENHI Grant-in-Aid for Scientific Research and Toukai Foundation for Technology.

  20. Physical Modelling of Bucket Foundation Under Long-Term Cyclic Lateral Loading

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    Offshore wind farms are a promising renewable energy source. The monopod bucket foundation has the potential to become a reliable and cost-effective concept for offshore wind turbines. The bucket foundation must be designed by accounting for the cyclic loading which might endanger the turbine...... functioning. In this article a 1g physical model of bucket foundation under horizontal and moment cyclic loading is described. A testing program including four tests was carried out. Every test was conducted for at least 30000 cycles, each with different loading features. The capability of the model...

  1. Correlation between movement complexity during static standing and balance function in institutionalized older adults

    Directory of Open Access Journals (Sweden)

    Yamagata M

    2017-03-01

    Full Text Available Momoko Yamagata,1 Tome Ikezoe,1 Midori Kamiya,1 Mitsuhiro Masaki,2,3 Noriaki Ichihashi1 1Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, 2Department of Physical Therapy, 3Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan Purpose: Sample entropy (SampEn is an analysis to evaluate movement complexity of the center of pressure (COP. A lower value of SampEn indicates lower complexity of COP variability, that is, rigidity, and lower degrees of freedom. Previous studies reported the association of increased SampEn with improved standing balance ability in young subjects. However, no studies have examined these relationships among older adults. Thus, we aimed to investigate the relationship between SampEn and standing balance ability in older adults.Subjects and methods: The subjects were 33 institutionalized older adults (aged 82.2±6.5 years. COP during static standing was measured. The standard deviation (SD values of COP and SampEn in the sagittal and frontal planes were calculated using time series data. One-leg standing test (OLST, functional reach (FR test, and lateral reach (LR test were also measured to evaluate standing balance ability.Results: OLST, FR, and LR were 6.5±8.3 s, 19.8±5.9 cm, and 18.2±6.4 cm, respectively. Pearson correlation analysis revealed that SampEn in the sagittal plane significantly correlated with OLST (r=-0.35 and FR (r=-0.36. However, SampEn in the frontal plane and SD of COP in both sagittal and frontal planes had no relationship with any of the clinical balance tests.Conclusion: Lower SampEn implies rigidity for postural control. In the present study, it was found that lower SampEn in the sagittal plane was related to a higher balance function, which suggests that older adults utilized body rigidity to maintain postural stability as a compensative strategy. Keywords: older adults, posture, balance, standing, complexity

  2. Experimental Study on Vacuum Dynamic Consolidation Treatment of Soft Soil Foundation

    Science.gov (United States)

    Fu-lai, Ni; Xin, Wen; Xiao-bin, Zhang; Wei, Li

    2017-11-01

    In view of the deficiency of the saturated silt clay foundation reinforced by the dynamic consolidation method, combination the project of soft foundation treatment test area in Tangshan, the reaserch analysed indexes, included groundwater level, pore water pressure, settlement about soil layer and so on, by use of field tests and indoor geotechnical tests, The results showed that the whole reinforcement effect with vacuum dynamic compaction method to blow fill foundation is obvious, due to the result of vacuum precipitation, generally, the excess pore water pressure can be dissipated by 90% above in 2 days around and the effective compaction coefficient can reached more than 0.9,the research work in soft foundation treatment engineering provide a new method and thought to similar engineering.

  3. Corrective Action Investigation Plan for Corrective Action Unit 252: Area 25 Engine Test Stand 1 Decontamination Pad, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    1999-08-20

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit 252 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 252 consists of Corrective Action Site (CAS) 25-07-02, Engine Test Stand-1 (ETS-1) Decontamination Pad. Located in Area 25 at the intersection of Road H and Road K at the Nevada Test Site, ETS-1 was designed for use as a mobile radiation checkpoint and for vehicle decontamination. The CAS consists of a concrete decontamination pad with a drain, a gravel-filled sump, two concrete trailer pads, and utility boxes. Constructed in 1966, the ETS-1 facility was part of the Nuclear Rocket Development Station (NRDS) complex and used to test nuclear rockets. The ETS-1 Decontamination Pad and mobile radiation check point was built in 1968. The NRDS complex ceased primary operations in 1973. Based on site history, the focus of the field investigation activities will be to determine if any primary contaminants of potential concern (COPCs) (including radionuclides, total volatile organic compounds, total semivolatile organic compounds, total petroleum hydrocarbons as diesel-range organics, Resource Conservation and Recovery Act metals, total pesticides, and polychlorinated biphenyls) are present at this site. Vertical extent of migration of suspected vehicle decontamination effluent COPCs is expected to be less than 12 feet below ground surface. Lateral extent of migration of COPCs is expected to be limited to the sump area or near the northeast corner of the decontamination pad. Using a biased sampling approach, near-surface and subsurface sampling will be conducted at the suspected worst-case areas including the sump and soil near the northeast corner of the decontamination pad. The results of this field investigation will support a defensible e

  4. Free-standing 3D polyaniline-CNT/Ni-fiber hybrid electrodes for high-performance supercapacitors

    Science.gov (United States)

    Li, Yuan; Fang, Yuzhu; Liu, Hong; Wu, Xiaoming; Lu, Yong

    2012-04-01

    Free-standing 3D macroscopic polyaniline (PANi)-carbon nanotube (CNT)-nickel fiber hybrids have been developed, and they deliver high specific capacitance (725 F g-1 at 0.5 A g-1) and high energy density at high rates (~22 W h kg-1 at 2000 W kg-1, based on total electrode mass) with good cyclability.Free-standing 3D macroscopic polyaniline (PANi)-carbon nanotube (CNT)-nickel fiber hybrids have been developed, and they deliver high specific capacitance (725 F g-1 at 0.5 A g-1) and high energy density at high rates (~22 W h kg-1 at 2000 W kg-1, based on total electrode mass) with good cyclability. Electronic supplementary information (ESI) available: Experimental details on preparation, characterization, and electrochemical testing; Fig. S1-S8, Schemes S1 and S2. See DOI: 10.1039/c2nr30252g

  5. Simulation of SEU transients in CMOS ICs

    International Nuclear Information System (INIS)

    Kaul, N.; Bhuva, B.L.; Kerns, S.E.

    1991-01-01

    This paper reports that available analytical models of the number of single-event-induced errors (SEU) in combinational logic systems are not easily applicable to real integrated circuits (ICs). An efficient computer simulation algorithm set, SITA, predicts the vulnerability of data stored in and processed by complex combinational logic circuits to SEU. SITA is described in detail to allow researchers to incorporate it into their error analysis packages. Required simulation algorithms are based on approximate closed-form equations modeling individual device behavior in CMOS logic units. Device-level simulation is used to estimate the probability that ion-device interactions produce erroneous signals capable of propagating to a latch (or n output node), and logic-level simulation to predict the spread of such erroneous, latched information through the IC. Simulation results are compared to those from SPICE for several circuit and logic configurations. SITA results are comparable to this established circuit-level code, and SITA can analyze circuits with state-of-the-art device densities (which SPICE cannot). At all IC complexity levels, SITAS offers several factors of 10 savings in simulation time over SPICE

  6. The Search for Wolf-Rayet Stars in IC10

    Science.gov (United States)

    Tehrani, Katie; Crowther, Paul; Archer, Isabelle

    2017-11-01

    We present a deep imaging and spectroscopic survey of the Local Group starburst galaxy IC10 using Gemini North/GMOS to unveil the global Wolf-Rayet population. It has previously been suggested that for IC10 to follow the WC/WN versus metallicity dependence seen in other Local Group galaxies, a large WN population must remain undiscovered. Our search revealed 3 new WN stars, and 5 candidates awaiting confirmation, providing little evidence to support this claim. We also compute an updated nebular derived metallicity of log(O/H)+12=8.40 +/- 0.04 for the galaxy using the direct method. Inspection of IC10 WR average line luminosities show these stars are more similar to their LMC, rather than SMC counterparts.

  7. The on scene command and control system (OSC2) : an integrated incident command system (ICS) forms-database management system and oil spill trajectory and fates model

    International Nuclear Information System (INIS)

    Anderson, E.; Galagan, C.; Howlett, E.

    1998-01-01

    The On Scene Command and Control (OSC 2 ) system is an oil spill modeling tool which was developed to combine Incident Command System (ICS) forms, an underlying database, an integrated geographical information system (GIS) and an oil spill trajectory and fate model. The first use of the prototype OSC 2 system was at a PREP drill conducted at the U.S. Coast Guard Marine Safety Office, San Diego, in April 1998. The goal of the drill was to simulate a real-time response over a 36-hour period using the Unified Command System. The simulated spill was the result of a collision between two vessels inside San Diego Bay that caused the release of 2,000 barrels of fuel oil. The hardware component of the system which was tested included three notebook computers, two laser printers, and a poster printer. The field test was a success but it was not a rigorous test of the system's capabilities. The map display was useful in quickly setting up the ICS divisions and groups and in deploying resources. 6 refs., 1 tab., 5 figs

  8. Comparison Study on I&C System Architecture of the Third Generation NPP Between EPR 1600 and US-APWR 1700

    International Nuclear Information System (INIS)

    Nafi Feridian; Arief Heru Kuncoro

    2009-01-01

    In order to support government's programs on research and development of nuclear energy, so a comparative study has been conducted on I&C system architecture of the third generation Nuclear Power Plant (NPP) of EPR 1600 and US-APWR 1700. I&C system is one of supporting systems in nuclear power plant in such away that the nuclear reactor operation can be safely and control. This study compares parameters on main structure of I&C system architecture related with safety system of nuclear power plant operation.The methodology of this study are literature study, data collection, review and analysis. It can be concluded although the two system have some have similarities, both of them have implemented a modern digital and computerized I&C system architecture with high ability of safety level and suitable with American code standard. But in general, they have difference parameters, such as classification of safety-related and non safety-related group, control and monitoring system, supporting systems of defence in depth and also supporting systems of I&C safety. (author)

  9. Effect of foot placements during sit to stand transition on timed up and go test in stroke subjects: A cross sectional study.

    Science.gov (United States)

    Joshua, Abraham M; Karnad, Shreekanth D; Nayak, Akshatha; Suresh, B V; Mithra, Prasanna; Unnikrishnan, B

    2017-01-01

    Timed up and go (TUG) test is been used as a screening tool for the assessment of risk of falling in individuals following stroke. Though TUG test is a quick test, it has fair sensitivity compared to other tests. This study was carried out to obtain and compare test scores for different types of foot placements during sit to stand transition in stroke subjects. A Cross-sectional study with purposive sampling included 28 post stroke subjects who were able to walk 6 meter with or without assistance. Timed Up and Go test was carried out with four different types of foot placements and scores were recorded. The data were compared using Kruskal-Wallis One way analysis of variance and Wilcoxon signed ranks test. There were comparable differences between asymmetric 1 test strategy which involved affected extremity to be placed behind the unaffected and other test strategies (Z = -4.457,-3.848,-4.458; p = 0.000). The initial foot placements during sit to stand transition influenced the time taken to complete the test which was significantly higher in asymmetric 1 strategy, Incorporation of the initial foot placement mainly asymmetric 1 strategy into conventional TUG test would help in identifying accurately the subject's functional mobility and postural stability.

  10. The zero inflation of standing dead tree carbon stocks

    Science.gov (United States)

    Christopher W. Woodall; David W. MacFarlane

    2012-01-01

    Given the importance of standing dead trees in numerous forest ecosystem attributes/processes such as carbon (C) stocks, the USDA Forest Service’s Forest Inventory and Analysis (FIA) program began consistent nationwide sampling of standing dead trees in 1999. Modeled estimates of standing dead tree C stocks are currently used as the official C stock estimates for the...

  11. Mechanized systems for early stand tending in central and eastern Canada

    Energy Technology Data Exchange (ETDEWEB)

    Ryans, M.; St-Amour, M. [Forest Engineering Research Inst. of Canada, Pointe Claire, PQ (Canada)

    1996-12-31

    Machines are currently being used for early stand tending in central and eastern Canada, but account for only 1 to 2% of the annual total for mechanical treatments (including manual and motor-manual operations). Selective and non-selective systems are used, depending on the application and stand conditions. Plantation cleaning operations and precommercial thinning (spacing) of naturally regenerated and seeded stands have been mechanized. Selective methods, primarily for plantation cleaning, use equipment with specialized prime movers, booms and controls, and cutting heads. This paper describes the Canadian experience to date based on FERIC`s studies of successful and unsuccessful operations, and lists the key features of a machine suitable for use in selective treatments. Strip precommercial thinning is used in denser natural stands, but limited improvements in crop-tree growth occur unless a motor-manual follow-up releases crop trees in the leave strips. Most off-the-shelf brushcutting equipment is not optimal for this application, primarily because it is too wide to meet local spacing prescriptions. Some applications such as the spacing of older natural stands have proven difficult to mechanize. Technical, biological, operational , regulatory, economic and social constraints prevent wider use of mechanized systems. Nonetheless, some machines are in operational use, and mechanized plantation cleaning is tested in some regions as an alternative to herbicides. 11 refs, 2 figs, 1 tab

  12. Standing footprint diagnostic method

    Science.gov (United States)

    Fan, Y. F.; Fan, Y. B.; Li, Z. Y.; Newman, T.; Lv, C. S.; Fan, Y. Z.

    2013-10-01

    Center of pressure is commonly used to evaluate standing balance. Even though it is incomplete, no better evaluation method has been presented. We designed our experiment with three standing postures: standing with feet together, standing with feet shoulder width apart, and standing with feet slightly wider than shoulder width. Our platform-based pressure system collected the instantaneous plantar pressure (standing footprint). A physical quantity of instantaneous standing footprint principal axis was defined, and it was used to construct an index to evaluate standing balance. Comparison between results from our newly established index and those from the center of pressure index to evaluate the stability of different standing postures revealed that the standing footprint principal axis index could better respond to the standing posture change than the existing one. Analysis indicated that the insensitive response to the relative position between feet and to the standing posture change from the center of pressure could be better detected by the standing footprint principal axis index. This predicts a wide application of standing footprint principal axis index when evaluating standing balance.

  13. Kaiser Family Foundation - Content Search

    Data.gov (United States)

    U.S. Department of Health & Human Services — Chartpacks, chartbooks, factsheets, reports, and slide presentations bring Kaiser Family Foundation information to life, and can be easily incorporated into your...

  14. Take a Stand!

    DEFF Research Database (Denmark)

    Danquah, I. H.; Kloster, S.; Holtermann, A.

    2017-01-01

    workers in total) were cluster randomized for intervention or control. The intervention included the appointment of local ambassadors, management support, environmental changes, a lecture and a workshop. Sitting time was measured using an ActiGraph GT3X+ fixed on the thigh. Data were processed using Acti4......Background: Prolonged sitting time has been associated with adverse health outcomes. Interventions at work may contribute to reduced sitting. The objective was to test if a multicomponent work-based intervention can reduce sitting time and the number of prolonged sitting periods (> 30 min......), increase the number of sit-to-stand transitions and decrease waist circumference and body fat percentage among office workers. Primary outcomes were: change in sitting time, prolonged sitting periods and sit-to-stand transitions at followup 1 month later. Methods: At four workplaces, 19 offices (317...

  15. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    Energy Technology Data Exchange (ETDEWEB)

    Rovati, L; Bonaiuti, M [Dipartimento di Ingegneria dell' Informazione, Universita di Modena e Reggio Emilia, Modena (Italy); Bettarini, S [Dipartimento di Fisica, Universita di Pisa and INFN Pisa, Pisa (Italy); Bosisio, L [Dipartimento di Fisica, Universita di Trieste and INFN Trieste, Trieste (Italy); Dalla Betta, G-F; Tyzhnevyi, V [Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento e INFN Trento, Trento (Italy); Verzellesi, G [Dipartimento di Scienze e Metodi dell' Ingegneria, Universita di Modena e Reggio Emilia and INFN Trento, Reggio Emilia (Italy); Zorzi, N, E-mail: giovanni.verzellesi@unimore.i [Fondazione Bruno Kessler (FBK), Trento (Italy)

    2009-11-15

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  16. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    International Nuclear Information System (INIS)

    Rovati, L; Bonaiuti, M; Bettarini, S; Bosisio, L; Dalla Betta, G-F; Tyzhnevyi, V; Verzellesi, G; Zorzi, N

    2009-01-01

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  17. Practical Soil-Shallow Foundation Model for Nonlinear Structural Analysis

    Directory of Open Access Journals (Sweden)

    Moussa Leblouba

    2016-01-01

    Full Text Available Soil-shallow foundation interaction models that are incorporated into most structural analysis programs generally lack accuracy and efficiency or neglect some aspects of foundation behavior. For instance, soil-shallow foundation systems have been observed to show both small and large loops under increasing amplitude load reversals. This paper presents a practical macroelement model for soil-shallow foundation system and its stability under simultaneous horizontal and vertical loads. The model comprises three spring elements: nonlinear horizontal, nonlinear rotational, and linear vertical springs. The proposed macroelement model was verified using experimental test results from large-scale model foundations subjected to small and large cyclic loading cases.

  18. Campaign Seeks Buy-In for High School Reforms: "Stand Up" Aims to Rouse Public Support

    Science.gov (United States)

    Robelen, Erik W.

    2006-01-01

    Kicked off the week of April 10, 2006 with a big plug on "The Oprah Winfrey Show," a new campaign spearheaded by the Bill & Melinda Gates Foundation is aiming to drum up public action to address what its organizers see as a crisis in America's public high schools. The Stand Up campaign comes as high schools have emerged as a focus of public-policy…

  19. Evaluation of Thermal and Thermo-mechanical Behavior of Full-scale Energy Foundations

    Science.gov (United States)

    Murphy, Kyle D.

    heating). . The second case study evaluated the thermal and thermo-mechanical properties of eight full-scale energy foundations constructed as part of a new building at the U.S. Air Force Academy (USAFA). The foundations were constructed as part of this project, using lessons learned from the other case history in Denver. The foundations were designed so that the impact of 5 different heat exchanger configurations on the thermal response of the foundations could be assessed through evaluation of the temperatures of the heat exchanger fluids entering and exiting the foundations. The thermal response tests were analyzed using the infinite line source analysis to determine the apparent system thermal conductivity of four foundations. The heat exchange per unit meter was also assessed as a secondary measure of the thermal response of the foundations as the assumptions of the line source method are not fully satisfied. The thermal response tests were also compared to evaluate the impact of the run-out length from the heat pump to the location of the foundations, and to assess the role of different geometrical configurations of the heat exchangers within the foundations. A common conclusion from both studies is that the sum of the mechanical axial stresses and the thermal axial stresses are less than both the tensile and unconfined compressive strength of the concrete. Even if the foundations were fully restrained from moving by side friction and end restraints at the head and toe, the thermal axial stresses would be less than those set in most design regulations (0.33 f'c). The mobilized side shear stresses in both projects tended to increase with depth, and the magnitudes were consistent with the undrained shear strength of stiff soils. The thermal axial displacements estimated by integrating the thermal axial strain values were not sufficient to lead to angular distortions that would cause structural or aesthetic damage to the overlying structure or connecting utilities

  20. Refuge alternatives relief valve testing and design with updated test stand.

    Science.gov (United States)

    Lutz, T J; Bissert, P T; Homce, G T; Yonkey, J A

    2018-03-01

    Underground refuge alternatives require an air source to supply breathable air to the occupants. This requires pressure relief valves to prevent unsafe pressures from building up within the refuge alternative. The U.S. Mine Safety and Health Administration (MSHA) mandates that pressure relief valves prevent pressure from exceeding 1.25 kPa (0.18 psi), or as specified by the manufacturer, above mine atmospheric pressure when a fan or compressor is used for the air supply. The U.S. National Institute for Occupational Safety and Health (NIOSH) tested a variety of pressure relief valves using an instrumented test fixture consisting of data acquisition equipment, a centrifugal blower, ductwork and various sensors to determine if the subject pressure relief valves meet the MSHA requirement. Relief pressures and flow characteristics, including opening pressure and flow rate, were measured for five different pressure relief valves under a variety of conditions. The subject pressure relief valves included two off-the-shelf modified check valves, two check valves used in MSHA-approved built-in-place refuge alternatives, and a commercially available valve that was designed for a steel refuge alternative and is currently being used in some built-in-place refuge alternatives. The test results showed relief pressures ranging from 0.20 to 1.53 kPa (0.03 to 0.22 psi) and flow rates up to 19.3 m 3 /min (683 scfm). As tested, some of the pressure relief valves did not meet the 1.25 kPa (0.18 psi) relief specification.

  1. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  2. Corporate Foundations

    DEFF Research Database (Denmark)

    Herlin, Heidi; Thusgaard Pedersen, Janni

    2013-01-01

    action between business and NGOs through convening, translation, collaboration, and mediation. Our study provides valuable insights into the tri-part relationship of company foundation NGO by discussing the implications of corporate foundations taking an active role in the realm of corporate social...... responsibility (CSR). The paper hence illuminates the fascinating and overlooked role of corporate foundations as potential bridges between business and civil society. It also informs theory on boundary organizations by clarifying challenges and limits of such institutions.......This paper aims to explore the potential of Danish corporate foundations as boundary organizations facilitating relationships between their founding companies and non-governmental organizations (NGOs). Hitherto, research has been silent about the role of corporate foundations in relation to cross...

  3. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    Science.gov (United States)

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  4. Foundation Investigation for Ground Based Radar Project-Kwajalein Island, Marshall Islands

    Science.gov (United States)

    1990-04-01

    iL_ COPY MISCELLANEOUS PAPER GL-90-5 i iFOUNDATION INVESTIGATION FOR GROUND BASED RADAR PROJECT--KWAJALEIN ISLAND, MARSHALL ISLANDS by Donald E...C!assification) Foundatioa Investigation for Ground Based Radar Project -- Kwajalein Island, Marshall Islands 12. PERSONAL AUTHOR(S) Yule, Donald E...investigation for the Ground Based Radar Project -- Kwajalein Island, Marshall Islands , are presented.- eophysical tests comprised of surface refrac- tion

  5. Vacuum system design considerations of the Los Alamos Accelerator Test Stand (ATS)

    International Nuclear Information System (INIS)

    Wilson, N.G.

    1986-01-01

    The accelerator test stand (ATS), in operation at the Los Alamos National Laboratory, includes a hydrogen ion source, low- and high-energy beam-transport sections, and a 425-MHz radio-frequency quadrupole (RFQ) linear accelerator. A 425-MHz drift-tube linac (DTL) and a powered ''buncher'' matching section have been constructed and will be installed on the ATS. The vacuum systems required for the various sections of the ATS are designed to provide: (1) high gas-load capability, as required in the ion source, and (2) high-vacuum capability in the high-power, radio-frequency accelerator sections (where fast vacuum-system response time is of importance) through the use of distributed, differential pumping as a principal vacuum-system feature. This paper describes properties of accelerator materials, vacuum-systems engineering and analysis, vacuum equipment used, and ATS vacuum-system performance

  6. StandsSIM-MD: a Management Driven forest SIMulator

    Directory of Open Access Journals (Sweden)

    Susana Barreiro

    2016-07-01

    Full Text Available Aim of the study: The existing stand level forest simulators available in Portugal were not developed with the aim of including up-to-date model versions and were limited in terms of accounting for forest management. The simulators’ platform, sIMfLOR was recently created to implement different growth models with a common philosophy. The objective was developing one easily-updatable, user-friendly, forest management and climate change sensitive simulator capable of projecting growth for the main tree species in Portugal. Area of the study: Portugal. Material and methods: The new simulator was programmed in a modular form consisting of several modules. The growth module integrates different forest growth and yield models (empirical and process-based for the main wood production tree species in Portugal (eucalypt, umbrella and maritime pines; whereas the management module drives the growth projections along the planning horizon according to a range of forest management approaches and climate (at present only available for eucalypt. Main results: The main result is the StandsSIM-MD Management Driven simulator that overcomes the limitations of the existing stand level simulators. It is a step forward when compared to the models currently available in the sIMfLOR platform covering more tree species, stand structures and stand compositions. It is focused on end-users and it is based on similar concepts regarding the generation of required inputs and generated outputs. Research highlights: -          Forest Management Driven simulations approach -          Multiple Prescriptions-Per-Stand functionality -          StandsSIM-MD can be used to support landowners decisions on stand forest management -          StandsSIM-MD simulations at regional level can be combined with optimization routines Keywords: Forest simulator, Forest Management Approaches; StandsSIM-MD; forest management.

  7. Design verification enhancement of field programmable gate array-based safety-critical I&C system of nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ibrahim [Department of Nuclear Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do 17104 (Korea, Republic of); Jung, Jaecheon, E-mail: jcjung@kings.ac.kr [Department of Nuclear Power Plant Engineering, KEPCO International Nuclear Graduate School, 658-91 Haemaji-ro, Seosang-myeon, Ulju-gun, Ulsan 45014 (Korea, Republic of); Heo, Gyunyoung [Department of Nuclear Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do 17104 (Korea, Republic of)

    2017-06-15

    Highlights: • An enhanced, systematic and integrated design verification approach is proposed for V&V of FPGA-based I&C system of NPP. • RPS bistable fixed setpoint trip algorithm is designed, analyzed, verified and discussed using the proposed approaches. • The application of integrated verification approach simultaneously verified the entire design modules. • The applicability of the proposed V&V facilitated the design verification processes. - Abstract: Safety-critical instrumentation and control (I&C) system in nuclear power plant (NPP) implemented on programmable logic controllers (PLCs) plays a vital role in safe operation of the plant. The challenges such as fast obsolescence, the vulnerability to cyber-attack, and other related issues of software systems have currently led to the consideration of field programmable gate arrays (FPGAs) as an alternative to PLCs because of their advantages and hardware related benefits. However, safety analysis for FPGA-based I&C systems, and verification and validation (V&V) assessments still remain important issues to be resolved, which are now become a global research point of interests. In this work, we proposed a systematic design and verification strategies from start to ready-to-use in form of model-based approaches for FPGA-based reactor protection system (RPS) that can lead to the enhancement of the design verification and validation processes. The proposed methodology stages are requirement analysis, enhanced functional flow block diagram (EFFBD) models, finite state machine with data path (FSMD) models, hardware description language (HDL) code development, and design verifications. The design verification stage includes unit test – Very high speed integrated circuit Hardware Description Language (VHDL) test and modified condition decision coverage (MC/DC) test, module test – MATLAB/Simulink Co-simulation test, and integration test – FPGA hardware test beds. To prove the adequacy of the proposed

  8. Design verification enhancement of field programmable gate array-based safety-critical I&C system of nuclear power plant

    International Nuclear Information System (INIS)

    Ahmed, Ibrahim; Jung, Jaecheon; Heo, Gyunyoung

    2017-01-01

    Highlights: • An enhanced, systematic and integrated design verification approach is proposed for V&V of FPGA-based I&C system of NPP. • RPS bistable fixed setpoint trip algorithm is designed, analyzed, verified and discussed using the proposed approaches. • The application of integrated verification approach simultaneously verified the entire design modules. • The applicability of the proposed V&V facilitated the design verification processes. - Abstract: Safety-critical instrumentation and control (I&C) system in nuclear power plant (NPP) implemented on programmable logic controllers (PLCs) plays a vital role in safe operation of the plant. The challenges such as fast obsolescence, the vulnerability to cyber-attack, and other related issues of software systems have currently led to the consideration of field programmable gate arrays (FPGAs) as an alternative to PLCs because of their advantages and hardware related benefits. However, safety analysis for FPGA-based I&C systems, and verification and validation (V&V) assessments still remain important issues to be resolved, which are now become a global research point of interests. In this work, we proposed a systematic design and verification strategies from start to ready-to-use in form of model-based approaches for FPGA-based reactor protection system (RPS) that can lead to the enhancement of the design verification and validation processes. The proposed methodology stages are requirement analysis, enhanced functional flow block diagram (EFFBD) models, finite state machine with data path (FSMD) models, hardware description language (HDL) code development, and design verifications. The design verification stage includes unit test – Very high speed integrated circuit Hardware Description Language (VHDL) test and modified condition decision coverage (MC/DC) test, module test – MATLAB/Simulink Co-simulation test, and integration test – FPGA hardware test beds. To prove the adequacy of the proposed

  9. 30 CFR 57.22203 - Main fan operation (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main fan operation (I-C mines). 57.22203... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22203 Main fan operation (I-C mines). Main fans shall be operated continuously while ore production is in progress. ...

  10. Gravity where do we stand ?

    CERN Document Server

    Colpi, Monica; Gorini, Vittorio; Moschella, Ugo

    2016-01-01

    This book presents an overview of the current understanding of gravitation, with a focus on the current efforts to test its theories, especially general relativity. It shows how the quest for a deeper understanding, which would possibly incorporate gravity in the quantum realm, is more than ever an open field. The majority of the contributions deals with the manifold facets of “experimental gravitation”, but the book goes beyond this and covers a broad range of subjects from the foundations of gravitational theories to astrophysics and cosmology. The book is divided into three parts. The first part deals with foundations and Solar System tests. An introductory pedagogical chapter reviews first Newtonian gravitational theory, special relativity, the equivalence principle and the basics of general relativity. Then it focuses on approximation methods, mainly the post-Newtonian formalism and the relaxed Einstein equations, with a discussion on how they are used in treating experimental tests and in the proble...

  11. Financial Audit: Congressional Award Foundation's Fiscal Years 2007 and 2006 Financial Statements

    National Research Council Canada - National Science Library

    Sebastian, Steven J

    2008-01-01

    .... generally accepted accounting principles;, establishing, maintaining, and assessing the Foundation s internal control to provide reasonable assurance that the Foundation s control objectives are met...

  12. Role of the Frontal Cortex in Standing Postural Sway Tasks While Dual-Tasking: A Functional Near-Infrared Spectroscopy Study Examining Working Memory Capacity

    Directory of Open Access Journals (Sweden)

    Hiroyuki Fujita

    2016-01-01

    Full Text Available Posture control during a dual-task involves changing the distribution of attention resources between the cognitive and motor tasks and involves the frontal cortex working memory (WM. The present study aimed to better understand the impact of frontal lobe activity and WM capacity in postural control during a dual-task. High and low WM-span groups were compared using their reading span test scores. High and low WM capacity were compared based on cognitive and balance performance and hemoglobin oxygenation (oxyHb levels during standing during single (S-S, standing during dual (S-D, one leg standing during single (O-S, and one leg standing during dual (O-D tasks. For sway pass length, significant difference in only the O-D task was observed between both groups. oxyHb levels were markedly increased in the right dorsolateral prefrontal cortex and supplementary motor area in the high-span group during a dual-task. Therefore, WM capacity influenced the allocation of attentional resources and motor performance.

  13. Effect of Embedment on the Vertical Bearing Capacity of Bucket Foundations in Clay

    DEFF Research Database (Denmark)

    Barari, Amin; Ibsen, Lars Bo

    2011-01-01

    To evaluate the undrained behaviour of bucket foundations installed on Yoldia clay, 100 tests on bucket foundations subject to vertical and moment loadings were conducted at Aalborg university geotechnical centre. Bucket foundations are tubular steel foundations that are installed by sealing...

  14. IN-SYNC. III. THE DYNAMICAL STATE OF IC 348—A SUPER-VIRIAL VELOCITY DISPERSION AND A PUZZLING SIGN OF CONVERGENCE

    International Nuclear Information System (INIS)

    Cottaar, Michiel; Meyer, Michael R.; Covey, Kevin R.; Foster, Jonathan B.; Tan, Jonathan C.; Rio, Nicola da; Nidever, David L.; Chojnowski, S. Drew; Majewski, Steve; Skrutskie, Michael F.; Wilson, John C.; Zasowski, Gail; Flaherty, Kevin M.; Frinchaboy, Peter M.

    2015-01-01

    Most field stars will have encountered the highest stellar density and hence the largest number of interactions in their birth environment. Yet the stellar dynamics during this crucial phase are poorly understood. Here we analyze the radial velocities measured for 152 out of 380 observed stars in the 2–6 Myr old star cluster IC 348 as part of the SDSS-III APOGEE. The radial velocity distribution of these stars is fitted with one or two Gaussians, convolved with the measurement uncertainties including binary orbital motions. Including a second Gaussian improves the fit; the high-velocity outliers that are best fit by this second component may either (1) be contaminants from the nearby Perseus OB2 association, (2) be a halo of ejected or dispersing stars from IC 348, or (3) reflect that IC 348 has not relaxed to a Gaussian velocity distribution. We measure a velocity dispersion for IC 348 of 0.72 ± 0.07 km s −1 (or 0.64 ± 0.08 km s −1 if two Gaussians are fitted), which implies a supervirial state, unless the gas contributes more to the gravitational potential than expected. No evidence is found for a dependence of this velocity dispersion on distance from the cluster center or stellar mass. We also find that stars with lower extinction (in the front of the cloud) tend to be redshifted compared with stars with somewhat higher extinction (toward the back of the cloud). This data suggest that the stars in IC 348 are converging along the line of sight. We show that this correlation between radial velocity and extinction is unlikely to be spuriously caused by the small cluster rotation of 0.024 ± 0.013 km s −1 arcmin −1 or by correlations between the radial velocities of neighboring stars. This signature, if confirmed, will be the first detection of line of sight convergence in a star cluster. Possible scenarios for reconciling this convergence with IC 348's observed supervirial state include: (a) the cluster is fluctuating around a new virial

  15. Development of 20 kW input power coupler for 1.3 GHz ERL main linac. Component test at 30 kW IOT test stand

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Umemori, Kensei; Sakanaka, Shogo; Takahashi, Takeshi; Furuya, Takaaki; Shinoe, Kenji; Ishii, Atsushi; Nakamura, Norio; Sawamura, Masaru

    2009-01-01

    We started to develop an input coupler for a 1.3 GHz ERL superconducting cavity. Required input power is about 20 kW for the cavity acceleration field of 20 MV/m and the beam current of 100 mA in energy recovery operation. The input coupler is designed based on the STF-BL input coupler and some modifications are applied to the design for the CW 20 kW power operation. We fabricated input coupler components such as ceramic windows and bellows and carried out the high-power test of the components by using a 30 kW IOT power source and a test stand constructed for the highpower test. In this report, we mainly describe the results of the high-power test of ceramic window and bellows. (author)

  16. Age-Related Differences in Quality of Standing Balance Using a Composite Score

    NARCIS (Netherlands)

    Pasma, J.H.; Bijlsma, A.Y.; van der Bij, M.D.W.; Arendzen, J.H.; Meskers, C.G.M.; Maier, A.B.

    2014-01-01

    Background: Age-related differences in standing balance are not detected by testing the ability to maintain balance. Quality of standing balance might be more sensitive to detect age-related differences. Objective: To study age-related differences in quality of standing balance, center of pressure

  17. AGB stars as tracers to IC 1613 evolution.

    Science.gov (United States)

    Hashemi, S. A.; Javadi, A.; van Loon, J. Th.

    We are going to apply AGB stars to find star formation history for IC 1613 galaxy; this a new and simple method that works well for nearby galaxies. IC 1613 is a Local Group dwarf irregular galaxy that is located at distance of 750 kpc, a gas rich and isolated dwarf galaxy that has a low foreground extinction. We use the long period variable stars (LPVs) that represent the very final stage of evolution of stars with low and intermediate mass at the AGB phase and are very luminous and cool so that they emit maximum brightness in near-infrared bands. Thus near-infrared photometry with using stellar evolutionary models help us to convert brightness to birth mass and age and from this drive star formation history of the galaxy. We will use the luminosity distribution of the LPVs to reconstruct the star formation history-a method we have successfully applied in other Local Group galaxies. Our analysis shows that the IC 1613 has had a nearly constant star formation rate, without any dominant star formation episode.

  18. Comparação do teste modificado de fixação preferencial com o convencional em pacientes com estrabismo

    Directory of Open Access Journals (Sweden)

    Edson Procianoy

    2012-04-01

    Full Text Available OBJETIVO: Comparar a acurácia do teste de fixação preferencial quando o paciente olha e toca o objeto alvo ao invés de apenas olhá-lo, como convencionalmente descrito. MÉTODOS: Estudo piloto transversal e prospectivo, incluindo 40 pacientes estrábicos, com desvios maiores que 10 dioptrias prismáticas entre 7 e 30 anos. RESULTADOS: O teste modificado mostrou sensibilidade de 93% (IC 95%=68,53 -98,73% e especificidade de 77% (IC 95%=57,95 - 88,97%. O teste convencional apresentou sensibilidade de 93% (IC 95%=68,53 - 98,73% e especificidade 46% (IC 95%= 28,76 - 64,54%. CONCLUSÕES: Estes resultados sugerem que a modificação no teste de fixação preferencial, solicitando que o paciente toque o objeto alvo, possa reduzir os resultados falsos positivos do teste.

  19. Increasing the Value of Evaluation to Philanthropic Foundations

    Science.gov (United States)

    Greenwald, Howard P.

    2013-01-01

    This article synthesizes interview data from evaluation directors and top executives of philanthropic foundations on how evaluation might better advance their missions. In key informant interviews, respondents commented on the purposes of evaluation from the foundation's perspective, challenges to effective evaluation, and the means by which…

  20. A Herschel view of IC 1396 A: Unveiling the different sequences of star formation

    NARCIS (Netherlands)

    Sicilia-Aguilar, Aurora; Roccatagliata, Veronica; Getman, Konstantin; Henning, Thomas; Merín, Bruno; Eiroa, Carlos; Rivière-Marichalar, Pablo; Currie, Thayne

    Context. The IC 1396 A globule, located to the west of the young cluster Tr 37, is known to host many very young stars and protostars, and is also assumed to be a site of triggered star formation. Aims: Our aim is to test the triggering mechanisms and sequences leading to star formation in Tr 37 and

  1. Optimal Design, Reliability And Sensitivity Analysis Of Foundation Plate

    Directory of Open Access Journals (Sweden)

    Tvrdá Katarína

    2015-12-01

    Full Text Available This paper deals with the optimal design of thickness of a plate rested on Winkler’s foundation. First order method was used for the optimization, while maintaining different restrictive conditions. The aim is to obtain a minimum volume of the foundation plate. At the end some probabilistic and safety analysis of the deflection of the foundation using LHS Monte Carlo method are presented.

  2. Fracture toughness of silicon nitride thin films of different thicknesses as measured by bulge tests

    International Nuclear Information System (INIS)

    Merle, B.; Goeken, M.

    2011-01-01

    A bulge test setup was used to determine the fracture toughness of amorphous low-pressure chemical vapor deposited (LPCVD) silicon nitride films with various thicknesses in the range 40-108 nm. A crack-like slit was milled in the center of each free-standing film with a focused ion beam, and the membrane was deformed in the bulge test until failure occurred. The fracture toughness K IC was calculated from the pre-crack length and the stress at failure. It is shown that the membrane is in a transition state between pure plane-stress and plane-strain which, however, had a negligible influence on the measurement of the fracture toughness, because of the high brittleness of silicon nitride and its low Young's modulus over yield strength ratio. The fracture toughness K IC was found to be constant at 6.3 ± 0.4 MPa m 1/2 over the whole thickness range studied, which compares well with bulk values. This means that the fracture toughness, like the Young's modulus, is a size-independent quantity for LPCVD silicon nitride. This presumably holds true for all amorphous brittle ceramic materials.

  3. Design, development and testing of real time control and data acquisition system for R&D IC H&CD source

    Energy Technology Data Exchange (ETDEWEB)

    Rajnish, Kumar, E-mail: krajnish@iter-india.org [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Soni, Dipal; Verma, Sriprakash; Patel, Hriday; Trivedi, Rajesh; Singh, Raghuraj; Patel, Manoj; Mukherjee, Aparajita [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Makadia, Keyur [Optimized Solutions Pvt. Ltd., Ahmedabad, Gujarat (India)

    2016-11-15

    Highlights: • Application program of LCU is developed using LabVIEW™ to operate megawatt RF source. • PXI 6133 module is used for acquiring data with 1 MHz sampling frequency in trigger mode. • PXI 6255 is used for continuous acquisition with 1 KHz sampling frequency. • PXI 7841 R is used for hard wired fast protection function and for real time control loop. • Schneider PLC is used to develop sequence control system. - Abstract: One of the important auxiliary heating and current drive systems for ITER experiment is Ion Cyclotron Heating & Current Drive (IC H&CD) system. ITER requires 1 prototype and 8 independent RF Sources, each having capability to deliver constant output power of 2.5 MW at VSWR 2 in the frequency range of 35–65 MHz. To meet the ITER requirement, an R&D program has been launched to identify the final stage tube (Tetrode/Diacrode) for MW level RF amplifier, along with other critical components. Under this R&D program, single chain of RF cascaded amplifiers, consisting of low & high power RF sections, auxiliary power supply, Anode power supply and test bench simulating ITER requirement, are being developed. To ensure reliable and safe operation of the entire system, PLC/PXI based Local Control Unit (LCU) is developed. PLC based sequential control system is developed for sequential biasing of electrodes of high power vacuum tubes (Tetrode/Diacrode). To protect the RF Source against critical fault condition, local protection logic is developed using PXI-7841R, which will ensure fast shut off (<10 μs) of RF and power supplies. Constant and stable power output even with variable load condition (up to VSWR 2) is achieved by employing two real time feedback control loops-one for making constant output power and the other one for optimizing anode & screen grid dissipation. For fault/offline analysis, event based acquisition and logging functionality is provided that acquires and logs data at 1 μs sampling rate for 100 ms pre and post time

  4. National Patient Safety Foundation

    Science.gov (United States)

    ... News Member Testimonials Lifetime Members Stand Up for Patient Safety Welcome Stand Up Members Stand Up e-News ... PLS Webcast Archives Stand Up Templates and Logos Patient Safety Coalition Coalition Overview Coalition Member Roster Members-Only ...

  5. Cold war, quantum foundations, and East-West collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Skaar-Jacobsen, Anja [Niels Bohr Archive, Copenhagen (Germany)

    2011-07-01

    It is well-known that the cultural cold war changed the ideological line in the Soviet Union from the late 1940s and that this had serious implications for the autonomy of research in genetics and quantum foundations in the East bloc. However, besides the more narrow concern from the point of view of research in quantum foundations, I suggest that the ideological impact on quantum foundations also constituted an obstacle for attempts by Western physicists to bring about a rapprochement between physics in the east and west in general. In connection with re-establishing East-West co-operation between physicists after Stalin's death in 1953 this obstacle needed to be cleared away. In my talk I discuss these issues and how the Institute for Theoretical Physics in Copenhagen came to be an important meeting place for physicists from the East and West from the mid-1950s.

  6. 30 CFR 57.22241 - Advance face boreholes (I-C mines).

    Science.gov (United States)

    2010-07-01

    ...) Boreholes shall be drilled in such a manner to insure that the advancing face will not accidently break into... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Advance face boreholes (I-C mines). 57.22241... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22241 Advance face boreholes (I-C mines...

  7. Cost-efficient foundation structures for large offshore wind farms

    International Nuclear Information System (INIS)

    Birch, C.; Gormsen, C.; Lyngesen, S.; Rasmussen, J. L.; Juhl, H.

    1997-01-01

    This paper presents the results of the development of a cost-efficient foundation for large (1.5 MW) offshore wind farms at water depth of 5 to 11 m. Previously, medium sized wind turbines (500 kW) in Denmark have been installed offshore at water depths of approximately 5 m on concrete gravity foundations. The installation of larger turbines at greater depth does, however, hold great promise in terms of wind environment and environmental considerations. The costs of a traditional gravity foundation at these increased water depths is expected to be prohibitive, and the aim of the project has been to reduce the foundations costs in general. This paper describes the theoretical basis for the geotechnical and structural design of three alternative concepts and presents an optimised layout of each based on a research and development project. The basis has been a wind farm consisting of 100 turbines. The R and D project has been undertaken by the consulting engineers Nellemann, Nielsen and Rauschenberger A/S (Gravity foundation), LICengineering A/S (Mono pile) and Ramboell (Tripod) in co-operation with the Danish utility engineering companies Elkraft and Elsamprojekt A/S. The project was partly financed by the participants and by the Danish Energy Agency through their 1996 Energy Research Programme (EFP-96). (au) 18 refs

  8. Mechanical design considerations of a standing wave s-band accelerator with on-axis couplers

    International Nuclear Information System (INIS)

    Hodge, S.B.; Funk, L.W.; Schriber, S.O.

    1976-01-01

    The mechanical design of S-band standing wave accelerator structures with on-axis coupling cells includes material selection, cavity design, segment production, rf tuning and brazing procedures. Pre-assembly tuning operations have been minimized by determining segment dimensions and tolerances so that segments can easily be fabricated in a near-finished condition by a commercial machining firm. Final tuning, if necessary, is easily achieved by removal of material from the cavity wall or drift tube nose. Considerations in choosing brazing procedures were vacuum integrity, resistivity of brazing alloy, joint thickness, alignment of the structure assembly and restriction of grain growth. (author)

  9. Teaching Development of Foundation Environmental Science Course Using Undergraduate Handbook of Buriram Rajabhat University

    Directory of Open Access Journals (Sweden)

    Kuntida Thammamrat

    2017-06-01

    Full Text Available The present study is an attempt to apply the handbook as a tool for teaching foundation of environmental science. The aims of this investigation were 1 to develop a course handbook that fills the standard criteria of 80/80 2 to compare mean derived from pretest and posttest scores 3 to compare student’s attitude toward environmental science from the pretest and posttest scores and 4 to compare student’s environmental scientific skills prior to and after using a study handbook. The key informants were 56 students drawn from 1st- year students of Environmental Science Department of Buriram Rajabhat University in 2558 (B.E academic year. Four instruments of data collection were constructed including 1 the course handbook 2 test of student’s basic knowledge on environmental science, 3 the test of student’s attitude toward environmental science, and 4 the test of student’s environmental scientific skills. The statistics analysis in this study comprised frequency percentage, mean, standard deviation and dependent t – test, which were of used for examining the hypothesis. The findings of this investigation revealed that 1 the efficiency of the handbook entitled “Foundation of environmental science” met the criteria of 80/80 in all aspects with value 83.93/91.81 2 the scores derived from student’s posttest is higher than pretest with .05 statistical significant difference 3 teaching through the handbook enhanced the level of student attitude toward environmental science with .05 statistical significant difference and 4 the environmental scientific skills of the students learning through the handbook are significantly higher than before, at .05 level.

  10. PENGARUH MEKANISME CORPORATE GOVERNANCE TERHADAP PENGUNGKAPAN INTELLECTUAL CAPITAL: PADA PERUSAHAAN IC INTENSIVE

    Directory of Open Access Journals (Sweden)

    Dista Amalia Arifah

    2012-12-01

    Full Text Available Intangible asset proxied by Intellectual Capital has important role to drive companies values creation. Although many companies have applied corporate governance mechanism in order to have IC disclosure recognition, most of them do not focus on Intellectual Capital disclosure yet. The aim of this study is to analyze the influence of corporate governance mechanisms consisting of size of the board commissioners, the independence level of independent commissioner, the activities of independent commissioners, and audit committee on the intellectual capital disclosures of the companies listed in BEI in 2009 using intensive ICs category with the adding of kontrol variables. This study will provide an illustration on how the mechanisms of corporate governance practices and IC disclosure become a value creation source for the company. There are a total of 176 companies categorized as IC intensive. Using a purposive sampling method, 45 companies were selected as samples. The 2009 annual reports of the companies are used as secondary data source of this research. Furthermore, to get ICs disclosure data content analysis technique was used both for quantity and quality terms. The results indicate that audit committee is the only corporate governance mechanism that significantly affects the level of IC disclosures.

  11. Unique structure of iC3b resolved at a resolution of 24 Å by 3D-electron microscopy.

    Science.gov (United States)

    Alcorlo, Martin; Martínez-Barricarte, Ruben; Fernández, Francisco J; Rodríguez-Gallego, César; Round, Adam; Vega, M Cristina; Harris, Claire L; de Cordoba, Santiago Rodríguez; Llorca, Oscar

    2011-08-09

    Activation of C3, deposition of C3b on the target surface, and subsequent amplification by formation of a C3-cleaving enzyme (C3-convertase; C3bBb) triggers the effector functions of complement that result in inflammation and cell lysis. Concurrently, surface-bound C3b is proteolyzed to iC3b by factor I and appropriate cofactors. iC3b then interacts with the complement receptors (CR) of the Ig superfamily, CR2 (CD21), CR3 (CD11b/CD18), and CR4 (CD11c/CD18) on leukocytes, down-modulating inflammation, enhancing B cell-mediated immunity, and targeting pathogens for clearance by phagocytosis. Using EM and small-angle X-ray scattering, we now present a medium-resolution structure of iC3b (24 Å). iC3b displays a unique conformation with structural features distinct from any other C3 fragment. The macroglobulin ring in iC3b is similar to that in C3b, whereas the TED (thioester-containing domain) domain and the remnants of the CUB (complement protein subcomponents C1r/C1s, urchin embryonic growth factor and bone morphogenetic protein 1) domain have moved to locations more similar to where they were in native C3. A consequence of this large conformational change is the disruption of the factor B binding site, which renders iC3b unable to assemble a C3-convertase. This structural model also justifies the decreased interaction between iC3b and complement regulators and the recognition of iC3b by the CR of the Ig superfamily, CR2, CR3, and CR4. These data further illustrate the extraordinary conformational versatility of C3 to accommodate a great diversity of functional activities.

  12. Comparison of fracture toughness (K{sub IC}) and strain energy release rate (G) of selected nuclear graphites

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Se-Hwan, E-mail: shchi@kaeri.re.kr

    2016-08-01

    The fracture behaviors of six nuclear graphite grades for a high-temperature gas-cooled reactor (HTGR), which differed in coke particle size and forming method, were characterized based on the ASTM standard graphite fracture toughness test method (ASTM D 7779-11) at room temperature. The G appeared to show good correlation with the fracture surface roughness and the G-Δa curves appeared to describe the fracture process well from crack initiation to failure. Comparison of the local (K{sub IC}) and gross (G{sub IC}, G-Δa) fracture parameters showed that the resistance to crack initiation and propagation was higher in the extruded or vibration molded medium particle size grades (PCEA, NBG-17, NBG-18: EVM group) than in the iso-molded fine particle size grades (IG-110, IG-430, NBG-25: IMF group). The ASTM may need to provide a guideline for G-Δa curve analysis. The K{sub IC} appeared to increase with specimen thickness (size).

  13. Improved Performance of Connected Foundations for Resilient Energy Transmission Infrastructure in Soft Soils

    Directory of Open Access Journals (Sweden)

    Doohyun Kyung

    2015-12-01

    Full Text Available The connected foundation is an effective structural type of foundation that can improve the sustainability of electrical transmission towers in soft soils to serve as a resilient energy supply system. In this study, the performance of electrical transmission towers reinforced with connected beams was investigated using a series of field load tests. Model transmission tower structures were manufactured and adopted into the tests. Based on the load capacity mobilization and failure mechanism, a criterion to define the load carrying capacity for connected foundation was proposed. It was found that the performance of connected foundation varies with the mechanical property of connection beam. The load capacity and differential settlement increased and decreased, respectively, with increasing connection beam stiffness. Such effect of connection beam was more pronounced as the height of load application point or tower height (zh increases. Based on the load test results, a design model was proposed that can be used to evaluate the sustainable performance and load carrying capacity of connected foundations. Field load tests with prototype transmission tower structure models were conducted to check and confirm the performance of connected foundation and the proposed design method.

  14. Adaptive plasticity model for bucket foundations

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Barari, Amin; Larsen, Kim A.

    2014-01-01

    Based on experimental investigations, the literature proposes different methods for modeling the behavior and capacity of foundations subjected to combined loading. Generally, two methods are used to predict the behavior of foundations: traditional approaches and hardening plasticity solutions......, potential, and failure surfaces are found to be dependent on the embedment ratio (i.e., ratio of skirt length to the diameter) and load path. For the models tested, associated flow is observed to be plausible in the radial planes, whereas nonassociated flow is observed in the planes along the V-axis....

  15. Drive Stands

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Systems Laboratory (ESL)houses numerous electrically driven drive stands. A drive stand consists of an electric motor driving a gearbox and a mounting...

  16. ALMA Maps of Dust and Warm Dense Gas Emission in the Starburst Galaxy IC 5179

    Science.gov (United States)

    Zhao, Yinghe; Lu, Nanyao; Díaz-Santos, Tanio; Xu, C. Kevin; Gao, Yu; Charmandaris, Vassilis; van der Werf, Paul; Zhang, Zhi-Yu; Cao, Chen

    2017-08-01

    We present our high-resolution (0.″15 × 0.″13, ˜34 pc) observations of the CO (6-5) line emission, which probes the warm and dense molecular gas, and the 434 μm dust continuum emission in the nuclear region of the starburst galaxy IC 5179, conducted with the Atacama Large Millimeter Array (ALMA). The CO (6-5) emission is spatially distributed in filamentary structures with many dense cores and shows a velocity field that is characteristic of a circumnuclear rotating gas disk, with 90% of the rotation speed arising within a radius of ≲150 pc. At the scale of our spatial resolution, the CO (6-5) and dust emission peaks do not always coincide, with their surface brightness ratio varying by a factor of ˜10. This result suggests that their excitation mechanisms are likely different, as further evidenced by the southwest to northeast spatial gradient of both CO-to-dust continuum ratio and Pa-α equivalent width. Within the nuclear region (radius ˜ 300 pc) and with a resolution of ˜34 pc, the CO line flux (dust flux density) detected in our ALMA observations is 180 ± 18 Jy km s-1 (71 ± 7 mJy), which accounts for 22% (2.4%) of the total value measured by Herschel. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc.

  17. Cold Climate Foundation Retrofit Energy Savings: The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, L. F.; Steigauf, B.

    2013-04-01

    A split simulation whole building energy/3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

  18. Cold Climate Foundation Retrofit Energy Savings. The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Steigauf, Brianna [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2013-04-01

    A split simulation whole building energy / 3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

  19. Instrument Control (iC) – An Open-Source Software to Automate Test Equipment

    Science.gov (United States)

    Pernstich, K. P.

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming. PMID:26900522

  20. SOCIAL ACTIVITY OF RUSSIAN ORTHODOX CHURCH IN 1990-2000S: CONCEPTUAL FOUNDATIONS AND EXPERIENCE OF REALIZATION

    OpenAIRE

    Мария Александровна Симонова

    2014-01-01

    This article deals with the essential characteristics of the social activities of the Russian Orthodox Church in the 1990-2000s. There are characterized priorities, shape, effective practice of social work and examined the conceptual foundations of the social activities of the Russian Orthodox Church. The analysis enables to establish the conceptual framework and the specifics of the social activities implementation of the Russian Orthodox Church. Particular attention is paid to the study of ...

  1. SHAKING TABLE TEST AND EFFECTIVE STRESS ANALYSIS ON SEISMIC PERFORMANCE WITH SEISMIC ISOLATION RUBBER TO THE INTERMEDIATE PART OF PILE FOUNDATION IN LIQUEFACTION

    Science.gov (United States)

    Uno, Kunihiko; Otsuka, Hisanori; Mitou, Masaaki

    The pile foundation is heavily damaged at the boundary division of the ground types, liquefied ground and non-liquefied ground, during an earthquake and there is a possibility of the collapse of the piles. In this study, we conduct a shaking table test and effective stress analysis of the influence of soil liquefaction and the seismic inertial force exerted on the pile foundation. When the intermediate part of the pile, there is at the boundary division, is subjected to section force, this part increases in size as compared to the pile head in certain instances. Further, we develop a seismic resistance method for a pile foundation in liquefaction using seismic isolation rubber and it is shown the middle part seismic isolation system is very effective.

  2. Free-standing optoelectronic graphene-CdS-graphene oxide composite paper produced by vacuum-assisted self-assembly

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yong-Feng [Chinese Academy of Sciences, Key Laboratory of Carbon Materials, Institute of Coal Chemistry, Taiyuan (China); Graduate University of Chinese Academy of Sciences, Beijing (China); Liu, Yan-Zhen; Shen, Wen-Zhong; Yang, Yong-Gang; Wang, Mao-Zhang [Chinese Academy of Sciences, Key Laboratory of Carbon Materials, Institute of Coal Chemistry, Taiyuan (China); Wen, Yue-Fang [Zhejiang University, Department of Chemical and Biological Engineering, Hangzhou (China)

    2012-03-15

    Free-standing optoelectronic graphene-CdS-graphene oxide (G-CdS-GO) composite papers were prepared by vacuum-assisted self-assembly. G-CdS hybrids were first prepared by a hydrothermal method and GO acts as a dispersant which makes it easier to disperse them to form relatively stable aqueous suspensions for fabricating paper. Transmission electron microscopy shows that CdS quantum dots (QDs) with an average size of approximately 1-2 nm were distributed uniformly on the graphene sheets. Photoluminescence measurements for the as-prepared G-CdS-GO composite paper showed that the surface defect related emissions of attached CdS QDs decrease and blue shift obviously due to the change in particle size and the interaction of the surface of the CdS QDs with both the GO and the graphene sheets. The resulting paper holds great potential for applications in thin film solar cells, sensors, diodes, and so on. (orig.)

  3. Commissioning and early operating experience with the Fermilab horizontal test facility

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Chase, B.; Harms, E.; Hocker, A.; Prieto, P.; Reid, J.; Rowe, A.; Theilacker, J.; Votava, M.; /Fermilab

    2007-10-01

    Fermilab has constructed a facility for testing dressed superconducting radiofrequency (RF) cavities at 1.8 K with high-power pulsed RF. This test stand was designed to test both 9-cell 1.3 GHz TESLA-style cavities and 9-cell 3.9 GHz cavities being built by Fermilab for DESY's TTF-FLASH facility. An overview of the test stand and a description of its initial commissioning is described here.

  4. The ambiguity of standing in standing devices: a qualitative interview study concerning children and parents experiences of the use of standing devices.

    Science.gov (United States)

    Nordström, Birgitta; Näslund, Annika; Ekenberg, Lilly; Zingmark, Karin

    2014-10-01

    The aim of this study was to describe children's and parents' experiences of the significance of standing in a standing device. Individual interviews were performed with six children/teenagers (aged 7-19 years) and 14 parents. The interviews were transcribed and analyzed using a qualitative content analysis. The analysis resulted in the major theme, the duality of uprightness and the related themes: (1) the instrumental dimension of standing; (2) the social dimension of standing; and (3) the ambivalent dimension of standing. Each of the themes comprised several subthemes. There is an inherent duality related to the use of a standing device. Standing in a standing device was seen as a treatment of body structures and functions, as well as a possible source of pain. Standing was considered to influence freedom in activities and participation both positively and negatively. The parents experienced that standing influenced other peoples' views of their child, while the children experienced standing as a way to extend the body and as something that gave them benefits in some activities. Physiotherapists working with children should take into account both the social and physical dimensions of using a standing device and consider both the child's and the parents' views.

  5. Development of an ASD IC for the Micro Pixel Chamber

    CERN Document Server

    Orito, R; Kubo, H; Miuchi, K; Nagayoshi, T; Okada, Y; Takada, A; Takeda, A; Tanimori, T; Ueno, M

    2004-01-01

    A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($\\mu$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $\\mu$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD...

  6. Orthopaedic research and education foundation and industry.

    Science.gov (United States)

    Wurth, Gene R; Sherr, Judy H; Coffman, Thomas M

    2003-07-01

    Members of orthopaedic industry commit a significant amount of funds each year to support research and education programs that are directly related to their product(s). In addition, industry supports organizations such as the Orthopaedic Research and Education Foundation. The relationship between the Orthopaedic Research and Education Foundation and industry began in the early 1980s. The support to the Orthopaedic Research and Education Foundation from industry primarily has come in the form of unrestricted grants. These grants best can be looked at as an investment rather than a contribution. This form of giving, once called corporate philanthropy is more accurately referred to as strategic philanthropy. Members of industry make these investments to enhance their reputations, build brand awareness, market their products and services, improve employee morale, increase customer loyalty, and establish strategic alliances. The specialty of orthopaedics is among the leaders in medicine in the amount of funding raised within the specialty for research and education programs. This is because of the amount of support from members of industry and the surgeons. During the past 15 years, 40% of the annual support to the Orthopaedic Research and Education Foundation has come from industry and the balance has come from surgeons and members of lay public. Future industry support of the Orthopaedic Research and Education Foundation and other organizations within the specialty of orthopaedics will be dependent on the continued demonstration of tangible returns in areas described.

  7. Converter-Modulator Design and Operations for the ILC L-band Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Reass, William A.; /Los Alamos; Burkhart, C.; Adolphsen, Chris E.; Beukers, T.; Cassel, R.; de Lira, A.; Papas, C.; Nguyen, M.; Went, R.; /SLAC; Anderson, David E.; /Oak

    2007-09-10

    To facilitate a rapid response to the International Linear Collider (ILC) L-band development program at SLAC, a spare converter-modulator was shipped from LANL. This modulator was to be a spare for the spallation neutron source (SNS) accelerator at ORNL. The ILC application requires a 33% higher peak output power (15 MW) and output current (120 Amp). This presents significant design challenges to modify the existing hardware and yet maintain switching parameters and thermal cycling within the semiconductor component ratings. To minimize IGBT commutation and free-wheeling diode currents, a different set of optimizations, as compared to the SNS design, were used to tune the resonant switching networks. Additional complexities arose as nanocrystalline cores with different performance characteristics (as compared to SNS), were used to fabricate the resonant 'boost' transformers. This paper will describe the electrical design, modeling efforts, and resulting electrical performance as implemented for the ILC L-band test stand.

  8. Motor SUS i životna sredina / IC engine and environment

    Directory of Open Access Journals (Sweden)

    Zoran Građin

    2002-03-01

    Full Text Available Ekološki pokreti u svetu su sve aktivniji, zbog stvarne ugroženosti Zemlje Mnogobrojni su oblici i izvori zagađenja, a jedan od najvećih su motori sa unutrašnjim sagorevanjem, za koje se pretpostavlja da će još dugo dominirati kao pogonski agregati u mnogim oblastima primene. U vezi s tim moguće je delovati u dva smera: zamenom konvencionalnih goriva alternativnim i konstrukcionim izmenama na motorima radi smanjenja emisije i potrošnje goriva. Jedna od mogućnosti konstrukcionog poboljšanja motora je i smanjenje mehaničkih gubitaka, koji kod današnjih konstrukcija još uvek imaju znatan udeo u gubicima, pogotovo na parcijalnim režimima. Treba naglasiti da kompleksni problemi smanjenja potrošnje goriva i emisije izduvnih gasova motora (vozila mogu da se reše samo spregom razvoja automobilske i naftne industrije. / Ecological trends and movements in the modern world grow stronger and more active, due to a real danger of Earth pollution. One of the main sources of pollution are IC engines and their influence on environment is significant. However, conventional combustion engines still are and will be dominant powering systems for numerous future applications. Two solutions are possible answers to this problem: first, the replacement of conventional fuels by alternative ones and second, modifications on the IC engine design in order to decrease fuel emission and consumption. One of the solutions for the improvement of IC engine design is the modification of engine parts or their design, with great influence on the decrease of mechanical losses, especially on partial rating. Therefore, it is important to say that complex problems of engine (automotive decrease of fuel consumption and exhaust gas emission can be solved only by simultaneous development of oil and engine (automotive industry.

  9. Foundations of modern theoretical physics

    International Nuclear Information System (INIS)

    Rayski, J.

    1983-01-01

    A critical survey of classical and quantum mechanics, special relativity, quantum field theory as well as the theory of elementary particles and the foundations of general relativity is given. An attempt of a unified field theory formulation is done. (A.S.)

  10. Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations

    Energy Technology Data Exchange (ETDEWEB)

    Huelman, P. [NorthernSTAR, St. Paul, MN (United States); Goldberg, L. [NorthernSTAR, St. Paul, MN (United States); Jacobson, R. [NorthernSTAR, St. Paul, MN (United States)

    2015-05-01

    Basements in climates 6 and 7 can account for a fraction of a home's total heat loss when fully conditioned. Such foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with it. Because below-grade basements are increasingly used for habitable space, cold foundation walls pose challenges for moisture contribution, energy use, and occupant comfort.

  11. Evolution of power plant foundations in Nova Scotia

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.T.; Larade, M.; Myette, R.; MacIvor, T. [Nova Scotia Power Inc., Halifax, NS (Canada)

    2009-07-01

    Many thermal steam plants in Nova Scotia, including the first 3 units Dartmouth's Tufts Cove Generating Station, were constructed on bedrock and near the sea for easy access to cooling water. Major equipment foundations such as turbine/condenser foundations, boiler feed pump foundations and fan foundations are concrete block foundations that are designed to withstand the heavy equipment and environmental loads imposed throughout the service-life of the plant. This paper discussed the rationale for choosing different types of foundations at the 5 power generating units at the Tufts Cove Generating Station. Due to the presence of boulders, pipe piles were installed in drilled holes in 1995 for the unit 2 precipitator foundation. In 2005, micro-piles were installed for unit 1 and 3 precipitators because they were relatively non-protrusive for the congested urban site that was full of buried structures and services. Similarly, for the unit 4 and 5 sound wall foundations, the high resistance capacities for both downward and uplift loads of the micro-piles embedded into the bedrock proved to be very valuable. These tall wall structures are subject to very high wind loads and were constructed at a geotechnically challenged site. Good geotechnical investigation and consultation was shown to be the basis for good design and construction of foundation works. It was concluded that the lessons learned at Tufts Cove can be applied to other similar foundation designs. 7 refs., 10 figs.

  12. Geotechnical Properties of Makurdi Shale and Effects on Foundations

    African Journals Online (AJOL)

    Geotechnical Properties of Makurdi Shale and Effects on Foundations. IO Agbede, P Smart ... Ten disturbed soil samples were collected from a third site of a proposed site for a light building and subjected to engineering classification tests. Based on the outcome of the second set of experiments, a foundation other than the ...

  13. Polar localization of PhoN2, a periplasmic virulence-associated factor of Shigella flexneri, is required for proper IcsA exposition at the old bacterial pole.

    Directory of Open Access Journals (Sweden)

    Daniela Scribano

    Full Text Available Proper protein localization is critical for bacterial virulence. PhoN2 is a virulence-associated ATP-diphosphohydrolase (apyrase involved in IcsA-mediated actin-based motility of S. flexneri. Herein, by analyzing a ΔphoN2 mutant of the S. flexneri strain M90T and by generating phoN2::HA fusions, we show that PhoN2, is a periplasmic protein that strictly localizes at the bacterial poles, with a strong preference for the old pole, the pole where IcsA is exposed, and that it is required for proper IcsA exposition. PhoN2-HA was found to be polarly localized both when phoN2::HA was ectopically expressed in a Escherichia coli K-12 strain and in a S. flexneri virulence plasmid-cured mutant, indicating a conserved mechanism of PhoN2 polar delivery across species and that neither IcsA nor the expression of other virulence-plasmid encoded genes are involved in this process. To assess whether PhoN2 and IcsA may interact, two-hybrid and cross-linking experiments were performed. While no evidence was found of a PhoN2-IcsA interaction, unexpectedly the outer membrane protein A (OmpA was shown to bind PhoN2-HA through its periplasmic-exposed C-terminal domain. Therefore, to identify PhoN2 domains involved in its periplasmic polar delivery as well as in the interaction with OmpA, a deletion and a set of specific amino acid substitutions were generated. Analysis of these mutants indicated that neither the (183PAPAP(187 motif of OmpA, nor the N-terminal polyproline (43PPPP(46 motif and the Y155 residue of PhoN2 are involved in this interaction while P45, P46 and Y155 residues were found to be critical for the correct folding and stability of the protein. The relative rapid degradation of these amino acid-substituted recombinant proteins was found to be due to unknown S. flexneri-specific protease(s. A model depicting how the PhoN2-OmpA interaction may contribute to proper polar IcsA exposition in S. flexneri is presented.

  14. Polar localization of PhoN2, a periplasmic virulence-associated factor of Shigella flexneri, is required for proper IcsA exposition at the old bacterial pole.

    Science.gov (United States)

    Scribano, Daniela; Petrucca, Andrea; Pompili, Monica; Ambrosi, Cecilia; Bruni, Elena; Zagaglia, Carlo; Prosseda, Gianni; Nencioni, Lucia; Casalino, Mariassunta; Polticelli, Fabio; Nicoletti, Mauro

    2014-01-01

    Proper protein localization is critical for bacterial virulence. PhoN2 is a virulence-associated ATP-diphosphohydrolase (apyrase) involved in IcsA-mediated actin-based motility of S. flexneri. Herein, by analyzing a ΔphoN2 mutant of the S. flexneri strain M90T and by generating phoN2::HA fusions, we show that PhoN2, is a periplasmic protein that strictly localizes at the bacterial poles, with a strong preference for the old pole, the pole where IcsA is exposed, and that it is required for proper IcsA exposition. PhoN2-HA was found to be polarly localized both when phoN2::HA was ectopically expressed in a Escherichia coli K-12 strain and in a S. flexneri virulence plasmid-cured mutant, indicating a conserved mechanism of PhoN2 polar delivery across species and that neither IcsA nor the expression of other virulence-plasmid encoded genes are involved in this process. To assess whether PhoN2 and IcsA may interact, two-hybrid and cross-linking experiments were performed. While no evidence was found of a PhoN2-IcsA interaction, unexpectedly the outer membrane protein A (OmpA) was shown to bind PhoN2-HA through its periplasmic-exposed C-terminal domain. Therefore, to identify PhoN2 domains involved in its periplasmic polar delivery as well as in the interaction with OmpA, a deletion and a set of specific amino acid substitutions were generated. Analysis of these mutants indicated that neither the (183)PAPAP(187) motif of OmpA, nor the N-terminal polyproline (43)PPPP(46) motif and the Y155 residue of PhoN2 are involved in this interaction while P45, P46 and Y155 residues were found to be critical for the correct folding and stability of the protein. The relative rapid degradation of these amino acid-substituted recombinant proteins was found to be due to unknown S. flexneri-specific protease(s). A model depicting how the PhoN2-OmpA interaction may contribute to proper polar IcsA exposition in S. flexneri is presented.

  15. Particularities of flat foundations for offshore wind power plants; Besonderheiten bei Flachgruendungen fuer Offshore-Windenergieanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Miehe, Alina; Hartwig, Udo [Ed. Zueblin AG, Stuttgart (Germany). Technologiezentrum Erneuerbare Energien, Zentrale Technik

    2012-07-01

    Interest in offshore wind energy installations has increased significantly in Germany and globally. In Germany only foundation structures secured by piles are currently being constructed. However, a gravity foundation has major advantages in particular because of the self-restoring effect. In this contribution the soil mechanical behaviour of a gravity foundation is described and the currently valid standards and regulations for the dimensioning of the foundation listed. It is clear that regulations for gravity foundations in particular still require development. With regard to the test foundation, which has already been described in detail in previous publications, there follows a brief description of the laboratory programme and a short summary of the latest test foundation results. (orig.)

  16. The integrated circuit IC EMP transient state disturbance effect experiment method investigates

    International Nuclear Information System (INIS)

    Li Xiaowei

    2004-01-01

    Transient state disturbance characteristic study on the integrated circuit, IC, need from its coupling path outset. Through cable (aerial) coupling, EMP converts to an pulse current voltage and results in the impact to the integrated circuit I/O orifice passing the cable. Aiming at the armament system construction feature, EMP effect to the integrated circuit, IC inside the system is analyzed. The integrated circuit, IC EMP effect experiment current injection method is investigated and a few experiments method is given. (authors)

  17. Implementation of a new Foundations Concept for Offshore Wind Farms

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo

    2008-01-01

    The foundation principles for the recent major offshore wind farm projects in Europe have been dominated by two types of foundation solutions, the gravitational foundation and the monopile. A fully operational 3.0 MW offshore wind turbine was installed on a prototype of the bucket foundation...... at the test field in Frederikshavn in December 2002. A five-year research and development project has proven the bucket foundation to be feasible in suitable soil conditions in water depth from near shore to approximately 40 meters. The bucket foundation design reduces the steel weight by half compared...... with a traditional monopile solution and the installation of the bucket foundation is much easier and does not require heavy installation equipment. In this paper the full-scale field installation of the prototype is described. A design procedure has been developed in cooperation with the certifying party in order...

  18. Moving from irrelevant intellectual capital (IC) reporting to value-relevant IC disclosures: key learning points from the Danish experience

    DEFF Research Database (Denmark)

    Schaper, Stefan; Nielsen, Christian; Roslender, Robin

    2017-01-01

    , largely informed by an accounting perspective, towards IC-related disclosures. Design/methodology/approach – The paper draws on data obtained from 21 semi-structured interviews with respondents in 16 companies. The respondents were contacted following a genealogical exercise carried out on the 102...... with a recognised reporting vehicle such as the annual report, were also encountered. Research limitations/implications – The implications of this study are that timely, value-relevant IC disclosures and compliant reporting, primarily for accountability purposes, have the potential to coexist. In addition...... to the usual limitations of a semi-structured interview research design, respondents’ difficulties in clearly recalling events during the project after some 10-12 years is a further potential limitation. Additionally, the use of internet-based communication channels for disclosure purposes was in its infancy...

  19. The experiences of mastery of stand-by energy demand; Les experiences de MDE stand by

    Energy Technology Data Exchange (ETDEWEB)

    Schilken, P

    2001-07-01

    In the residential sector of the OECD countries, the electricity losses of domestic appliances in stand-by position represent 1.5% of the total electricity consumption. This study belongs to the SAVE project (pilot campaign of municipal utilities for an improved rational use of energy). Its aim is to observe the policies and experiments implemented by municipalities and municipal energy companies for the abatement of the electricity consumptions of stand-by origin. A working group consisting of the German Stadtwerke and some international partners have debated the possible actions and documents for an efficient information of the public. This document presents the brochures and local actions of this program. (J.S.)

  20. Numerical simulation of installation of skirt foundations

    Energy Technology Data Exchange (ETDEWEB)

    Vangelsten, Bjoern Vidar

    1997-12-31

    Skirt foundation has been increasingly used for permanent offshore oil installations and anchors for drilling ships. Suction is commonly used in skirt foundation installing. If a large amount of suction is applied, the soil around the foundation may fail and the foundation become useless. This thesis studies failure due to high seepage gradients, aiming to provide a basis for reducing the risk of such failures. Skirt penetration model testing has shown that to solve the problem one must understand what is going on at the skirt tip during suction installation. A numerical model based on micro mechanics was developed as continuum hypothesis was seen to be unsuitable to describe the processes in the critical phases of the failure. The numerical model combines two-dimensional elliptical particles with the finite difference method for flow to model water flow in a granular material. The key idea is to formulate the permeability as a function of the porosity of the grain assembly and so obtain an interaction between the finite difference method on flow and the particle movement. A computer program, DYNELL, was developed and used to simulate: (1) weight penetration of a skirt wall, (2) combined suction and weight penetration of a skirt wall, and (3) critical gradient tests around a skirt wall to study failure mechanisms. The model calculations agree well with laboratory experiments. 16 refs., 124 figs., 21 tabs.

  1. Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems; TOPICAL

    International Nuclear Information System (INIS)

    DeBlasio, R.; Durand, S.; Hansen, R.; Hutchinson, P.; Kroposki, B.; McNutt, P.; Rosenthal, A.; Thomas, M.

    1999-01-01

    This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested

  2. Impact of Fibromyalgia in the Sit-to-Stand-to-Sit Performance Compared With Healthy Controls.

    Science.gov (United States)

    Collado-Mateo, Daniel; Adsuar, Jose C; Dominguez-Muñoz, Francisco J; Olivares, Pedro R; Gusi, Narcis

    2017-06-01

    Fibromyalgia is associated with a reduction in the ability to perform activities of daily living. Sit-to-stand-to-sit performance is one of the most common activities of daily living and often is evaluated by counting the number of repetitions of the 30-second chair-stand test. No study, however, has examined the performance over the 30 seconds of this test of female patients with fibromyalgia on a phase-by-phase basis. To evaluate the impact of fibromyalgia on performance of the 30-second chair-stand test and to analyze how the kinematic performance changed over the 30-second test period. A cross-sectional study. Local association of fibromyalgia. Fifteen females with fibromyalgia and nine healthy female controls. Participants performed the 30-second chair-stand test while wearing a motion capture device. Duration of each sit-to-stand-to-sit phase within the 30-second time limit was compared between groups using repeated measures analysis of variance. The association between duration of phases and scores from the revised version of the Fibromyalgia Impact Questionnaire was tested using bivariate correlations. The duration of impulse and sit-to-stand phases were gradually increased over the 30 seconds of the chair-stand test for women with fibromyalgia compared with healthy controls (P = .04 and P = .02, respectively). The mean duration of these 2 phases was associated with symptom duration and the function domain of the revised version of the Fibromyalgia Impact Questionnaire (P fibromyalgia and healthy controls. Since sit-to-stand from a chair is a common daily activity, women with fibromyalgia may require specific exercises to improve performance of this task. Not applicable. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Innovative Teaching of IC Design and Manufacture Using the Superchip Platform

    Science.gov (United States)

    Wilson, P. R.; Wilcock, R.; McNally, I.; Swabey, M.

    2010-01-01

    This paper describes how an intelligent chip architecture has allowed a large cohort of undergraduate (UG) students to be given effective practical insight into integrated circuit (IC) design by designing and manufacturing their own ICs. To achieve this, an efficient chip architecture, the "Superchip," was developed, which allows multiple student…

  4. Joule heating induced thermomigration failure in un-powered microbumps due to thermal crosstalk in 2.5D IC technology

    Energy Technology Data Exchange (ETDEWEB)

    Li, Menglu; Tu, K. N., E-mail: kntu@ucla.edu [Department of Materials Science and Engineering, UCLA, Los Angeles, California 90095-1595 (United States); Kim, Dong Wook; Gu, Sam [Qualcomm, San Diego, California 92121 (United States); Parkinson, Dilworth Y.; Barnard, Harold [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2016-08-21

    Thermal-crosstalk induced thermomigration failure in un-powered microbumps has been found in 2.5D integrated circuit (IC) circuit. In 2.5D IC, a Si interposer was used between a polymer substrate and a device chip which has transistors. The interposer has no transistors. If transistors are added to the interposer chip, it becomes 3D IC. In our test structure, there are two Si chips placed horizontally on a Si interposer. The vertical connections between the interposer and the Si chips are through microbumps. We powered one daisy chain of the microbumps under one Si chip; however, the un-powered microbumps in the neighboring chip are failed with big holes in the solder layer. We find that Joule heating from the powered microbumps is transferred horizontally to the bottom of the neighboring un-powered microbumps, and creates a large temperature gradient, in the order of 1000 °C/cm, through the un-powered microbumps in the neighboring chip, so the latter failed by thermomigration. In addition, we used synchrotron radiation tomography to compare three sets of microbumps in the test structure: microbumps under electromigration, microbumps under thermomigration, and microbumps under a constant temperature thermal annealing. The results show that the microbumps under thermomigration have the largest damage. Furthermore, simulation of temperature distribution in the test structure supports the finding of thermomigration.

  5. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  6. Tilt table standing for reducing spasticity after spinal cord injury.

    Science.gov (United States)

    Bohannon, R W

    1993-10-01

    A patient with a T12 spinal cord injury and intractable extensor spasms of the lower extremities participated in tilt table standing trial on 5 nonconsecutive days to determine if the intervention would affect his spasticity and spasms. Each day's standing trial was followed by an immediate reduction in lower extremity spasticity (measured using the modified Ashworth scale and pendulum testing). Standing was also accompanied by a reduction in spasms that lasted until the following morning. The reduction of spasms was particularly advantageous to the performance of car transfers. Tilt table standing merits further examination as a physical treatment of spasms that accompany central nervous system lesions.

  7. Purification, crystallization and preliminary X-ray analysis of aminoglycoside-2′′-phosphotransferase-Ic [APH(2′′)-Ic] from Enterococcus gallinarum

    International Nuclear Information System (INIS)

    Byrnes, Laura J.; Badarau, Adriana; Vakulenko, Sergei B.; Smith, Clyde A.

    2008-01-01

    APH(2′′)-Ic is an enzyme that is responsible for high-level gentamicin resistance in E. gallinarum isolates. Crystals of the wild-type enzyme and three mutants have been prepared and a complete X-ray diffraction data set was collected to 2.15 Å resolution from an F108L crystal. Bacterial resistance to aminoglycoside antibiotics is primarily the result of deactivation of the drugs. Three families of enzymes are responsible for this activity, with one such family being the aminoglycoside phosphotransferases (APHs). The gene encoding one of these enzymes, aminoglycoside-2′′-phosphotransferase-Ic [APH(2′′)-Ic] from Enterococcus gallinarum, has been cloned and the wild-type protein (comprising 308 amino-acid residues) and three mutants that showed elevated minimum inhibitory concentrations towards gentamicin (F108L, H258L and a double mutant F108L/H258L) were expressed in Escherichia coli and subsequently purified. All APH(2′′)-Ic variants were crystallized in the presence of 14–20%(w/v) PEG 4000, 0.25 M MgCl 2 , 0.1 M Tris–HCl pH 8.5 and 1 mM Mg 2 GTP. The crystals belong to the monoclinic space group C2, with one molecule in the asymmetric unit. The approximate unit-cell parameters are a = 82.4, b = 54.2, c = 77.0 Å, β = 108.8°. X-ray diffraction data were collected to approximately 2.15 Å resolution from an F108L crystal at beamline BL9-2 at SSRL, Stanford, California, USA

  8. Effect of embedment on the plastic behaviour of Bucket Foundations

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Barari, Amin; Larsen, Kim André

    2015-01-01

    studies have indicated the possibility of defining foundation response using plasticity theory. Results of multiple loading tests addressing the effect of embedment on the strain-hardening behavior of shallow bucket foundations under combined loading are reported. The kinematic mechanisms accompanying pre......-failure are presented. It is argued that the drained capacity of offshore bucket foundations and the ratio of plastic increments are largely influenced by embedment depth and the preload ratio V/Vpeak....

  9. Stand-Alone Containment Analysis of the Phébus FPT Tests with the ASTEC and the MELCOR Codes: The FPT-0 Test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2017-01-01

    Full Text Available The integral Phébus tests were probably one of the most important experimental campaigns performed to investigate the progression of severe accidents in light water reactors. In these tests, the degradation of a PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the results of such tests, numerical codes such as ASTEC and MELCOR have been developed to describe the evolution of a severe accident. After the termination of the experimental Phébus campaign, these two codes were furthermore expanded. Therefore, the aim of the present work is to reanalyze the first Phébus test (FPT-0 employing the updated ASTEC and MELCOR versions to ensure that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The analysis focuses on the stand-alone containment aspects of this test, and the paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products behavior. This paper is part of a series of publications covering the four executed Phébus tests employing a solid PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3.

  10. Wireless Concrete Strength Monitoring of Wind Turbine Foundations

    Directory of Open Access Journals (Sweden)

    Marcus Perry

    2017-12-01

    Full Text Available Wind turbine foundations are typically cast in place, leaving the concrete to mature under environmental conditions that vary in time and space. As a result, there is uncertainty around the concrete’s initial performance, and this can encourage both costly over-design and inaccurate prognoses of structural health. Here, we demonstrate the field application of a dense, wireless thermocouple network to monitor the strength development of an onshore, reinforced-concrete wind turbine foundation. Up-to-date methods in fly ash concrete strength and maturity modelling are used to estimate the distribution and evolution of foundation strength over 29 days of curing. Strength estimates are verified by core samples, extracted from the foundation base. In addition, an artificial neural network, trained using temperature data, is exploited to demonstrate that distributed concrete strengths can be estimated for foundations using only sparse thermocouple data. Our techniques provide a practical alternative to computational models, and could assist site operators in making more informed decisions about foundation design, construction, operation and maintenance.

  11. Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

    Energy Technology Data Exchange (ETDEWEB)

    Antoni, V.; Agostinetti, P.; Brombin, M.; Cervaro, V.; Delogu, R.; Fasolo, D.; Franchin, L.; Ghiraldelli, R.; Molon, F.; Pasqualotto, R.; Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; Tollin, M.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); De Muri, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); INFN-LNL, v.le dell' Università 2, I-35020, Legnaro (PD) Italy (Italy); Ikeda, K.; Kisaki, M.; Nakano, H.; Takeiri, Y.; Tsumori, K. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Muraro, A. [Istituto di Fisica del Plasma (IFP-CNR) – Via Cozzi 53, 20125, Milano (Italy)

    2015-04-08

    In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

  12. Planning for Plume Diagnostics for Ground Testing of J-2X Engines at the SSC

    Science.gov (United States)

    SaintCyr, William W.; Tejwani, Gopal D.; McVay, Gregory P.; Langford, Lester A.; SaintCyr, William W.

    2010-01-01

    John C. Stennis Space Center (SSC) is the premier test facility for liquid rocket engine development and certification for the National Aeronautics and Space Administration (NASA). Therefore, it is no surprise that the SSC will play the most prominent role in the engine development testing and certification for the J-2X engine. The Pratt & Whitney Rocketdyne J-2X engine has been selected by the Constellation Program to power the Ares I Upper Stage Element and the Ares V Earth Departure Stage in NASA s strategy of risk mitigation for hardware development by building on the Apollo program and other lessons learned to deliver a human-rated engine that is on an aggressive development schedule, with first demonstration flight in 2010 and human test flights in 2012. Accordingly, J-2X engine design, development, test, and evaluation is to build upon heritage hardware and apply valuable experience gained from past development and testing efforts. In order to leverage SSC s successful and innovative expertise in the plume diagnostics for the space shuttle main engine (SSME) health monitoring,1-10 this paper will present a blueprint for plume diagnostics for various proposed ground testing activities for J-2X at SSC. Complete description of the SSC s test facilities, supporting infrastructure, and test facilities is available in Ref. 11. The A-1 Test Stand is currently being prepared for testing the J-2X engine at sea level conditions. The A-2 Test Stand is currently being used for testing the SSME and may also be used for testing the J-2X engine at sea level conditions in the future. Very recently, ground-breaking ceremony for the new A-3 rocket engine test stand took place at SSC on August 23, 2007. A-3 is the first large - scale test stand to be built at the SSC since the A and B stands were constructed in the 1960s. The A-3 Test Stand will be used for testing J-2X engines under vacuum conditions simulating high altitude operation at approximately 30,480 m (100,000 ft

  13. Investigation of Redistribution of Pile Foundation Forces Under Successive Loading of Its Elements

    Science.gov (United States)

    Sedin, Vladimir; Bikus, Kateryna; Kovba, Vladislav

    2017-12-01

    Redistribution of pile foundation forces under successive loading of its elements was investigated under laboratory conditions. A segment of pile foundation model was taken for use in the case study. Load tests on the pile foundation model segment, without joining its elements (pile and plate, which turns into grillage) and based on different combinations of static loadings were conducted. This proved that the loading of a plate causes skin friction on some length of the pile side surface as well as providing additional loading and settlement. Test results have shown that application of successive elements enables the foundation to carry loads up to 13% higher than in the case of a standard pile foundation loading with the same settlement rates.

  14. Prediction of unknown deep foundation lengths using the Hilbert Huang Transform (HHT

    Directory of Open Access Journals (Sweden)

    Ahmed T.M. Farid

    2012-08-01

    Full Text Available Prediction of unknown deep foundation embedment depth is a great deal nowadays, especially in case of upgrading or rehabilitation of old structures. Many old bridges and marine or pier structures in the United States are established using deep foundations system of timber piles and their foundation records do not exist. Non-Destructive Testing (NDT or Non-Destructive Evaluation (NDE method for a great variety of materials and structures has become an integral part of many tests. However, the process of testing long piles, deeply embedded in the ground, is more complex than (NDT of the other structural materials. This paper summarizes some of the most common non-destructive test methods for deep foundations and presents a new method called the Hilbert Huang Transform (HHT. This Hilbert Huang Transform (HHT method is used now by a wide range in a different health monitoring of many systems. In this paper, some field tests on the timber Piles of one bridge at North Carolina was performed to verify the using the (HHT method for predicting the embedded depth of the unknown piles. Percentage of the accuracy achieved using HHT method for pile length compared to the actual pile length data was performed. Finally, a recommendation is presented for the limitation of using this new method as a new non-destructive method for deep foundations.

  15. Classification of fMRI independent components using IC-fingerprints and support vector machine classifiers.

    Science.gov (United States)

    De Martino, Federico; Gentile, Francesco; Esposito, Fabrizio; Balsi, Marco; Di Salle, Francesco; Goebel, Rainer; Formisano, Elia

    2007-01-01

    We present a general method for the classification of independent components (ICs) extracted from functional MRI (fMRI) data sets. The method consists of two steps. In the first step, each fMRI-IC is associated with an IC-fingerprint, i.e., a representation of the component in a multidimensional space of parameters. These parameters are post hoc estimates of global properties of the ICs and are largely independent of a specific experimental design and stimulus timing. In the second step a machine learning algorithm automatically separates the IC-fingerprints into six general classes after preliminary training performed on a small subset of expert-labeled components. We illustrate this approach in a multisubject fMRI study employing visual structure-from-motion stimuli encoding faces and control random shapes. We show that: (1) IC-fingerprints are a valuable tool for the inspection, characterization and selection of fMRI-ICs and (2) automatic classifications of fMRI-ICs in new subjects present a high correspondence with those obtained by expert visual inspection of the components. Importantly, our classification procedure highlights several neurophysiologically interesting processes. The most intriguing of which is reflected, with high intra- and inter-subject reproducibility, in one IC exhibiting a transiently task-related activation in the 'face' region of the primary sensorimotor cortex. This suggests that in addition to or as part of the mirror system, somatotopic regions of the sensorimotor cortex are involved in disambiguating the perception of a moving body part. Finally, we show that the same classification algorithm can be successfully applied, without re-training, to fMRI collected using acquisition parameters, stimulation modality and timing considerably different from those used for training.

  16. Studying Radiation Tolerant ICs for LHC

    CERN Multimedia

    Faccio, F; Snoeys, W; Campbell, M; Casas-cubillos, J; Gomes, P

    2002-01-01

    %title\\\\ \\\\In the recent years, intensive work has been carried out on the development of custom ICs for the readout electronics for LHC experiments. As far as radiation hardness is concerned, attention has been focussed on high total dose applications, mainly for the tracker systems. The dose foreseen in this inner region is estimated to be higher than 1~Mrad/year. In the framework of R&D projects (RD-9 and RD-20) and in the ATLAS and CMS experiments, the study of different radiation hard processes has been pursued and good contacts with the manufacturers have been established. The results of these studies have been discussed during the Microelectronics User Group (MUG) rad-hard meetings, and now some HEP groups are working to develop radiation hard ICs for the LHC experiments on some of the available rad-hard processes.\\\\ \\\\In addition, a lot of the standard commercial electronic components and ASICs which are planned to be installed near the LHC machine and in the detectors will receive total doses in ...

  17. Effect of information feedback on training standing up following stroke: a pilot feasibility study.

    Science.gov (United States)

    Stanton, Rosalyn; Ada, Louise; Dean, Catherine M; Preston, Elisabeth

    2016-12-01

    The ability to stand up is reduced following stroke. Traditional biofeedback is effective in improving the performance of lower limb activities. The aim of this study was to investigate the feasibility of and potential for information feedback from a simple inexpensive device to improve the ability to stand up from a chair in people following stroke. A single-group study with pre-post measures design was used. Twenty people with hemiplegic stroke in inpatient rehabilitation received 10 sessions over 2 weeks of information feedback about foot placement during training of standing up. Progression involved increasing repetitions, increasing difficulty and fading feedback. Feasibility was determined by adherence, time taken, acceptability and safety. Clinical outcomes were the time taken to stand up, quality and foot position measured using the 5-Times-Sit-To-Stand-Test and carryover into daily activities measured by covert observation. The study was feasible with 97% of sessions completed, taking 19 (SD 6) to 25 (SD 10) minutes. Participants understood (4.6/5), found useful (4.6/5), challenging (4.4/5) and would recommend (4.7/5) the training. The time to stand up 5 times decreased by 24 (95% CI -48 to -1) s, and the quality of standing improved by 1.0/10.0 (95% CI 0.2 to 1.8). Carryover of the correct foot placement occurred to real life, with the beginning foot position correct 2.1/3.0 (95% CI 1.6 to 2.6) and end foot position correct 1.8/3.0 (95% CI 1.2 to 2.4) occasions. The training is feasible and has the potential to improve the ability to stand up.

  18. Joachim Heinrich Campe’s Robinson the Younger: Universal Moral Foundations and Intercultural Relations

    Directory of Open Access Journals (Sweden)

    Claudia Nitschke

    2016-06-01

    Full Text Available In his adaptation of Robinson Crusoe, Campe sets out to examine the legitimacy of his contemporary social reality (in Europe in the broadest sense by tracing its origin back to the most basic roots conceivable. The experimental character of his book is emphasised and—to an extent—explicitly introduced through the frame narrative which constitutes Campe’s most important addition to Defoe’s story: Here the emergence of the rules and routines are extensively mooted by the father (who relates Robinson’s story as a framed narrative and his children who still have to internalise, grasp, and situate the moral rules around them and frequently offer divergent perspectives in the process. The frame narrative connects the moral “ontogeny” of the children to the “phylogenetics” of civilisation and suggests that both can be superimposed on one another. I will work with concepts that focus on the differentiation between “innate” moral characteristics and their social transformation on a cognitive, evolutionary level, from which Campe clearly deviates. However, his short-circuiting of the individual and the phylogeny leads to very similar specifications as laid out by, for instance, Moral Foundations Theory.

  19. ABIM Foundation

    Science.gov (United States)

    ... In conjunction with the… mailchi.mp View on Facebook ABIM Foundation shared Business Radio Powered by The Wharton School's post. 2 days ago View on Facebook ABIM Foundation 2 days ago The Android version ...

  20. Scour and Scour Protection for Windturbine Foundations

    DEFF Research Database (Denmark)

    Larsen, Brian Juul; Frigaard, Peter

    A test programme has been performed to determine the necessary scour protection around a various types of foundation for an offshore windturbine. Furthermore the unprotected scour depths have been investigated....