Sample records for rupture life reliability

  1. Reliability assessment of creep rupture life for Gr. 91 steel

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Park, Jae-Young; Kim, Seon-Jin; Jang, Jinsung

    2013-01-01

    Highlights: • Statistical analysis of a number of creep rupture data based on Z parameter. • Determination of the constant C in LM parameter and long-term creep life prediction. • Generation of random variables for Z s and Z cr by Monte-Carlo simulation in a SCRI model. • Examples for design application were reasonably drawn from the viewpoints of reliability. - Abstract: This paper presents reliability assessment of the long-term creep life of Gr. 91 steel, which is a major structural material for high temperature structural components of Generation-IV reactor systems. A number of creep rupture data for Gr. 91 steel were collected through literature surveys, and the long-term creep life was predicted by Larson–Miller parameter. A “Z parameter” method was used to describe the magnitude of the deviation of the creep rupture data to a master curve. A “Service Condition-creep Rupture property Interference (SCRI) model” based on the Z parameter was used to simultaneously consider the scattering of the creep rupture data of materials and the fluctuations of service conditions in reliability assessment. A statistical analysis of the creep rupture data was conducted by the Z parameter. To carry out the SCRI model, a number of random variables for Z s describing service conditions and Z cr describing the dispersion of the creep rupture data were generated using a Monte-Carlo simulation technique. As examples for application, the creep rupture life under a certain service conditions of Gr. 91 steel was reasonably drawn from the viewpoints of reliability

  2. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  3. Reliability Evaluation on Creep Life Prediction of Alloy 617 for a Very High Temperature Reactor

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Hong, Sung-Deok; Kim, Yong-Wan; Park, Jae-Young; Kim, Seon-Jin

    2012-01-01

    This paper evaluates the reliability of creep rupture life under service conditions of Alloy 617, which is considered as one of the candidate materials for use in a very high temperature reactor (VHTR) system. A Z-parameter, which represents the deviation of creep rupture data from the master curve, was used for the reliability analysis of the creep rupture data of Alloy 617. A Service-condition Creep Rupture Interference (SCRI) model, which can consider both the scattering of the creep rupture data and the fluctuations of temperature and stress under any service conditions, was also used for evaluating the reliability of creep rupture life. The statistical analysis showed that the scattering of creep rupture data based on Z-parameter was supported by normal distribution. The values of reliability decreased rapidly with increasing amplitudes of temperature and stress fluctuations. The results established that the reliability decreased with an increasing service time.

  4. The Danish anal sphincter rupture questionnaire: Validity and reliability

    DEFF Research Database (Denmark)

    Due, Ulla; Ottesen, Marianne

    2008-01-01

    Objective. To revise, validate and test for reliability an anal sphincter rupture questionnaire in relation to construct, content and face validity. Setting and background. Since 1996 women with anal sphincter rupture (ASR) at one of the public university hospitals in Copenhagen, Denmark have bee...

  5. Reliability analysis for the creep rupture mode of failure

    International Nuclear Information System (INIS)

    Vaidyanathan, S.

    1975-01-01

    An analytical study has been carried out to relate the factors of safety employed in the design of a component to the probability of failure in the thermal creep rupture mode. The analysis considers the statistical variations in the operating temperature, stress and rupture time, and applies the life fraction damage criterion as the indicator of failure. Typical results for solution annealed type 304-stainless steel material for the temperature and stress variations expected in an LMFBR environment have been obtained. The analytical problem was solved by considering the joint distribution of the independent variables and deriving the distribution for the function associated with the probability of failure by integrating over proper regions as dictated by the deterministic design rule. This leads to a triple integral for the final probability of failure where the coefficients of variation associated with the temperature, stress and rupture time distributions can be specified by the user. The derivation is general, and can be used for time varying stress histories and the case of irradiated material where the rupture time varies with accumulated fluence. Example calculations applied to solution annealed type 304 stainless steel material have been carried out for an assumed coefficient of variation of 2% for temperature and 6% for stress. The results show that the probability of failure associated with dependent stress intensity limits specified in the ASME Boiler and Pressure Vessel Section III Code Case 1592 is less than 5x10 -8 . Rupture under thermal creep conditions is a highly complicated phenomenon. It is believed that the present study will help in quantizing the reliability to be expected with deterministic design factors of safety

  6. Validity and reliability of the Achilles tendon total rupture score.

    Science.gov (United States)

    Ganestam, Ann; Barfod, Kristoffer; Klit, Jakob; Troelsen, Anders

    2013-01-01

    The best treatment of acute Achilles tendon rupture remains debated. Patient-reported outcome measures have become cornerstones in treatment evaluations. The Achilles tendon total rupture score (ATRS) has been developed for this purpose but requires additional validation. The purpose of the present study was to validate a Danish translation of the ATRS. The ATRS was translated into Danish according to internationally adopted standards. Of 142 patients, 90 with previous rupture of the Achilles tendon participated in the validity study and 52 in the reliability study. The ATRS showed moderately strong correlations with the physical subscores of the Medical Outcomes Study 36-item Short-Form Health Survey (r = .70 to .75; p questionnaire (r = .71; p validity. For study and follow-up purposes, the ATRS seems reliable for comparisons of groups of patients. Its usability is limited for repeated assessment of individual patients. The development of analysis guidelines would be desirable. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. The Danish anal sphincter rupture questionnaire: Validity and reliability

    DEFF Research Database (Denmark)

    Due, Ulla; Ottesen, Marianne

    2008-01-01

    Objective. To revise, validate and test for reliability an anal sphincter rupture questionnaire in relation to construct, content and face validity. Setting and background. Since 1996 women with anal sphincter rupture (ASR) at one of the public university hospitals in Copenhagen, Denmark have been...... main questions but one. Two questions needed further explanation. Seven women made minor errors. Conclusion. The validated Danish questionnaire has a good construct, content and face validity. It is a well accepted, reliable, simple and clinically relevant screening tool. It reveals physical problems...... offered pelvic floor muscle examination and instruction by a specialist physiotherapist. In relation to that, a non-validated questionnaire about anal and urinary incontinence was to be answered six months after childbirth. Method. The original questionnaire was revised and a pilot test was performed...

  8. Reliability and validation of the Dutch Achilles tendon Total Rupture Score.

    Science.gov (United States)

    Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N

    2018-03-01

    Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.

  9. Composite Overwrap Pressure Vessels: Mechanics and Stress Rupture Lifing Philosophy

    Science.gov (United States)

    Thesken, John C.; Murthy, Pappu L. N.; Phoenix, Leigh

    2007-01-01

    The NASA Engineering and Safety Center (NESC) has been conducting an independent technical assessment to address safety concerns related to the known stress rupture failure mode of filament wound pressure vessels in use on Shuttle and the International Space Station. The Shuttle's Kevlar-49 fiber overwrapped tanks are of particular concern due to their long usage and the poorly understood stress rupture process in Kevlar-49 filaments. Existing long term data show that the rupture process is a function of stress, temperature and time. However due to the presence of load sharing liners and the complex manufacturing procedures, the state of actual fiber stress in flight hardware and test articles is not clearly known. Indeed non-conservative life predictions have been made where stress rupture data and lifing procedures have ignored the contribution of the liner in favor of applied pressure as the controlling load parameter. With the aid of analytical and finite element results, this paper examines the fundamental mechanical response of composite overwrapped pressure vessels including the influence of elastic-plastic liners and degraded/creeping overwrap properties. Graphical methods are presented describing the non-linear relationship of applied pressure to Kevlar-49 fiber stress/strain during manufacturing, operations and burst loadings. These are applied to experimental measurements made on a variety of vessel systems to demonstrate the correct calibration of fiber stress as a function of pressure. Applying this analysis to the actual qualification burst data for Shuttle flight hardware revealed that the nominal fiber stress at burst was in some cases 23% lower than what had previously been used to predict stress rupture life. These results motivate a detailed discussion of the appropriate stress rupture lifing philosophy for COPVs including the correct transference of stress rupture life data between dissimilar vessels and test articles.

  10. Validity and Reliability of the Achilles Tendon Total Rupture Score

    DEFF Research Database (Denmark)

    Ganestam, Ann; Barfod, Kristoffer; Klit, Jakob

    2013-01-01

    study was to validate a Danish translation of the ATRS. The ATRS was translated into Danish according to internationally adopted standards. Of 142 patients, 90 with previous rupture of the Achilles tendon participated in the validity study and 52 in the reliability study. The ATRS showed moderately......The best treatment of acute Achilles tendon rupture remains debated. Patient-reported outcome measures have become cornerstones in treatment evaluations. The Achilles tendon total rupture score (ATRS) has been developed for this purpose but requires additional validation. The purpose of the present...... = .07). The limits of agreement were ±18.53. A strong correlation was found between test and retest (intercorrelation coefficient .908); the standard error of measurement was 6.7, and the minimal detectable change was 18.5. The Danish version of the ATRS showed moderately strong criterion validity...

  11. Effect of heating method on stress-rupture life

    Science.gov (United States)

    Bizon, P. T.; Calfo, F. D.

    1977-01-01

    The effect of radiant(furnace), resistance(electric current), burner(hot gas stream), and a combination of resistance and burner heating on intermediate time (100 to 300 hr) stress-rupture life and reduction of area was evaluated. All heating methods were studied using the nickel-based alloy Udimet 700 while all but burner heating were evaluated with the cobalt-based alloy Mar-M 509. Limited test results of eight other superalloys were also included in this study. Resistance heated specimens had about 20 to 30 percent of the stress-rupture life of radiant heated specimens. The limited burner heating data showed about a 50 percent life reduction as compared to the radiant heated tests. A metallurgical examination gave no explanation for these reductions.

  12. New considerations on variability of creep rupture data and life prediction

    International Nuclear Information System (INIS)

    Kim, Seon Jin; Jeong, Won Taek; Kong, Yu Sik

    2009-01-01

    This paper deals with the variability analysis of short term creep rupture test data based on the previous creep rupture tests and the possibility of the creep life prediction. From creep tests performed by constant uniaxial stresses at 600, 650 and 700 .deg. C elevated temperature, in order to investigate the variability of short-term creep rupture data, the creep curves were analyzed for normalized creep strain divided by initial strain. There are some variability in thee creep rupture data. And, the difference between general creep curves and normalized creep curves were obtained. The effects of the creep rupture time and state steady creep rate on the Weibull distribution parameters were investigated. There were good relation between normal Weibull parameters and normalized Weibull parameters. Finally, the predicted creep life were compared with the Monkman-Grant model.

  13. New Considerations on Variability of Creep Rupture Data and Life Prediction

    International Nuclear Information System (INIS)

    Jung, Won Taek; Kong, Yu Sik; Kim, Seon Jin

    2009-01-01

    This paper deals with the variability analysis of short term creep rupture test data based on the previous creep rupture tests and the possibility of the creep life prediction. From creep tests performed by constant uniaxial stresses at 600, 650 and 700 .deg. C elevated temperature, in order to investigate the variability of short-term creep rupture data, the creep curves were analyzed for normalized creep strain divided by initial strain. There are some variability in the creep rupture data. And, the difference between general creep curves and normalized creep curves were obtained. The effects of the creep rupture time (RT) and steady state creep rate (SSCR) on the Weibull distribution parameters were investigated. There were good relation between normal Weibull parameters and normalized Weibull parameters. Finally, the predicted creep life were compared with the Monkman-Grant model

  14. Creep Rupture Life Prediction Based on Analysis of Large Creep Deformation

    Directory of Open Access Journals (Sweden)

    YE Wenming

    2016-08-01

    Full Text Available A creep rupture life prediction method for high temperature component was proposed. The method was based on a true stress-strain elastoplastic creep constitutive model and the large deformation finite element analysis method. This method firstly used the high-temperature tensile stress-strain curve expressed by true stress and strain and the creep curve to build materials' elastoplastic and creep constitutive model respectively, then used the large deformation finite element method to calculate the deformation response of high temperature component under a given load curve, finally the creep rupture life was determined according to the change trend of the responsive curve.The method was verified by durable test of TC11 titanium alloy notched specimens under 500 ℃, and was compared with the three creep rupture life prediction methods based on the small deformation analysis. Results show that the proposed method can accurately predict the high temperature creep response and long-term life of TC11 notched specimens, and the accuracy is better than that of the methods based on the average effective stress of notch ligament, the bone point stress and the fracture strain of the key point, which are all based on small deformation finite element analysis.

  15. Improvement of stress-rupture life of GTD-111 by second solution heat treatment

    International Nuclear Information System (INIS)

    Yang, Caixiong; Xu, Yulai; Zhang, Zixing; Nie, Heng; Xiao, Xueshan; Jia, Guoqing; Shen, Zhi

    2013-01-01

    Highlights: ► The second solution heat treatment promoted the solution of γ–γ′ eutectic into γ matrix. ► The volume fraction of γ′ increases significantly after adding the second solution heat treatment. ► The improved stress-rupture life is primarily due to the increased volume fraction of γ′ phase. -- Abstract: An added second solution heat treatment was conducted to investigate its effects on the microstructures and stress-rupture properties of GTD-111. The microstructures were analyzed by scanning electron microscope after each step of heat treatments. The stress-rupture life of GTD-111 dramatically increases from about 180 to 288 h at 871 °C/310 MPa after adding a second solution heat treatment. The added second solution heat treatment promoted the solution of γ–γ′ eutectic into γ matrix, and facilitated the nucleation and precipitate of the secondary γ′ particles. The distribution of γ′ phase becomes much denser, the width of γ matrix channel is also reduced, and the volume fraction of γ′ phase significantly increases from about 29.3% to 44.2%. The improved stress-rupture life is primarily due to the increased volume fraction of γ′ phase. The carbides mainly consist of MC and a small amount of M 23 C 6 , which may prevent the dislocation moving and/or grain boundary sliding, and further improve the stress-rupture properties of GTD-111.

  16. Prediction of creep-fatigue life by use of creep rupture ductility

    International Nuclear Information System (INIS)

    Yamaguchi, Koji; Suzuki, Naoyuki; Ijima, Kiyoshi; Kanazawa, Kenji

    1985-01-01

    It was clarified that tension strain hold reduced creep-fatigue life of many engineering materials in different degrees depending on material, temperature and test duration. However the reduction in the life due to holding for various durations could be correlated to the fraction of intergranular facets on fracture surfaces which was considered to be an index of the damage introduced during strain hold. This fraction of intergranular facets by creep-fatigue failure exhibited a direct relation to the creep rupture ductility of the material tested at the same temperature and for the same creep-fatigue life-time. From these results an empirical equation has been derived as follow; (Δ sub(epsilonsub(i)))/Dsub(c).(N sub(h sup(α))) = C, where Δ sub(epsilonsub(i)) is inelastic strain range, Dsub(c) is the creep rupture ductility for the same duration as creep-fatigue life time, Nsub(h) is the creep-fatigue life under tension strain hold conditions, and α and C are constants depending on the material and testing temperature. From the equation the life prediction is possible for a given inelastic strain range Δ sub(epsilonsub(i)) if the constants α and C, and Dsub(c) are known. The value of α was found to be 0.62 and 0.74 for various austenitic stainless steels and NCF800 at 600 0 C and 700 0 C, respectively, and 0.69 for 1 1/4Cr-1/2Mo steel at 600 0 C. The value of C was found to be 0.50 and 0.59 for various austenitic stainless steels and NCF800 at 600 0 C and 700 0 C, respectively, and 0.49 for 1 1/4Cr-1/2Mo steel at 600 0 C. The creep rupture ductility Dsub(c) is available in the NRIM Creep Data Sheets up to 10 5 h for multi-heats of many kinds of heat resistant alloys. (author)

  17. A method of creep rupture data extrapolation based on physical processes

    International Nuclear Information System (INIS)

    Leinster, M.G.

    2008-01-01

    There is a need for a reliable method to extrapolate generic creep rupture data to failure times in excess of the currently published times. A method based on well-understood and mathematically described physical processes is likely to be stable and reliable. Creep process descriptions have been developed based on accepted theory, to the extent that good fits with published data have been obtained. Methods have been developed to apply these descriptions to extrapolate creep rupture data to stresses below the published values. The relationship creep life parameter=f(ln(sinh(stress))) has been shown to be justifiable over the stress ranges of most interest, and gives realistic results at high temperatures and long times to failure. In the interests of continuity with past and present practice, the suggested method is intended to extend existing polynomial descriptions of life parameters at low stress. Where no polynomials exist, the method can be used to describe the behaviour of life parameters throughout the full range of a particular failure mode in the published data

  18. Rupture of primigravid uterus and recurrent rupture

    Directory of Open Access Journals (Sweden)

    Nahreen Akhtar

    2016-08-01

    Full Text Available Uterine rupture is a deadly obstetrical emergency endangering the life of both mother and fetus. In Bangladesh, majority of deliveries arc attended by unskilled traditional birth attendant and maternal mortality is still quite high. It is rare Ln developed country but unfortunately it is common in a developing country like Bangladesh. We report a case history of a patient age 32yrs from Daudkandi, Comilla admitted with H/0 previous two rupture uterus and repair with no living issue. We did caesarean section at her 31+ weeks of pregnancy when she developed Jabour pain. A baby of 1.4 kg was delivered. During cesarean section, focal rupture was noted in previous scar of rupture. Unfortunately the baby expired in neonatal ICU after 36 hours.

  19. Developing Reliable Life Support for Mars

    Science.gov (United States)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and

  20. Effect of cold works on creep-rupture life of type 316LN stainless steel

    International Nuclear Information System (INIS)

    Kim, W. G.; Han, C. H.; Ryu, W. S.

    2003-01-01

    Effect of cold works on creep-rupture life of the cold-worked type 316LN stainless steels, which are fabricated with the various reductions ; 0%(solution annealing), 20%, 30%, 40%, and 50%, was investigated. The creep-rupture time increased gradually up to 30% reduction, but it decreased inversely over 30% reduction. The longest rupture time exhibited at cold-worked reduction of 30%. The reason for this is that fine carbide precipitates are uniformly generated in grain boundary and the dislocations are pinned in the precipitates and the dislocations are sustained for a long time at high temperature. However, it is assumed that the higher cold-work reductions over 30% lead to excessive generation of deformation faults. The SEM fractrographs of the cold-worked specimens showed dense fracture micrographs, and they did not show intergranular structures in creep fracture mode. From this result, it is believed that the cold-worked specimens were superior in creep-rupture time to solution annealed ones

  1. Creep-rupture behavior of candidate Stirling engine iron supperalloys in high-pressure hydrogen. Volume 2: Hydrogen creep-rupture behavior

    Science.gov (United States)

    Bhattacharyya, S.; Peterman, W.; Hales, C.

    1984-01-01

    The creep rupture behavior of nine iron base and one cobalt base candidate Stirling engine alloys is evaluated. Rupture life, minimum creep rate, and time to 1% strain data are analyzed. The 3500 h rupture life stress and stress to obtain 1% strain in 3500 h are also estimated.

  2. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  3. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Frank, Michael, E-mail: michael.frank@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Pellerin, Olivier, E-mail: olivier@pellerin.as; Primio, Massimiliano Di, E-mail: massimiliano.di.primio@gmail.com; Angelopoulos, Georgios, E-mail: giorginos78@msn.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Boughenou, Marie-Fazia, E-mail: marie-fazia.boughenou@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Anesthesia and Surgical Intensive Care Unit (France); Pagny, Jean-Yves, E-mail: jean-yves.pagny@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Messas, Emmanuel, E-mail: emmanuel.messas@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France)

    2013-05-09

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture.

  4. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    International Nuclear Information System (INIS)

    Okada, Takuya; Frank, Michael; Pellerin, Olivier; Primio, Massimiliano Di; Angelopoulos, Georgios; Boughenou, Marie-Fazia; Pagny, Jean-Yves; Messas, Emmanuel; Sapoval, Marc

    2014-01-01

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture

  5. Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV Using Temperature and Pressure Acceleration

    Science.gov (United States)

    Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.

    2009-01-01

    Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.

  6. Predicting creep rupture from early strain data

    International Nuclear Information System (INIS)

    Holmstroem, Stefan; Auerkari, Pertti

    2009-01-01

    To extend creep life modelling from classical rupture modelling, a robust and effective parametric strain model has been developed. The model can reproduce with good accuracy all parts of the creep curve, economically utilising the available rupture models. The resulting combined model can also be used to predict rupture from the available strain data, and to further improve the rupture models. The methodology can utilise unfailed specimen data for life assessment at lower stress levels than what is possible from rupture data alone. Master curves for creep strain and rupture have been produced for oxygen-free phosphorus-doped (OFP) copper with a maximum testing time of 51,000 h. Values of time to specific strain at given stress (40-165 MPa) and temperature (125-350 deg. C) were fitted to the models in the strain range of 0.1-38%. With typical inhomogeneous multi-batch creep data, the combined strain and rupture modelling involves the steps of investigation of the data quality, extraction of elastic and creep strain response, rupture modelling, data set balancing and creep strain modelling. Finally, the master curves for strain and rupture are tested and validated for overall fitting efficiency. With the Wilshire equation as the basis for the rupture model, the strain model applies classical parametric principles with an Arrhenius type of thermal activation and a power law type of stress dependence for the strain rate. The strain model also assumes that the processes of primary and secondary creep can be reasonably correlated. The rupture model represents a clear improvement over previous models in the range of the test data. The creep strain information from interrupted and running tests were assessed together with the rupture data investigating the possibility of rupture model improvement towards lower stress levels by inverse utilisation of the combined rupture based strain model. The developed creep strain model together with the improved rupture model is

  7. Life-Threatening Retropharyngeal Hemorrhage Secondary to Rupture of the Inferior Thyroid Artery

    Directory of Open Access Journals (Sweden)

    Cristina G. Calogero

    2015-01-01

    Full Text Available Inferior thyroid artery (ITA rupture is rare and may progress to life-threatening conditions. We present a patient who visited the emergency department after an episode of syncope and dizziness in which he had a mechanical fall that resulted in abrasions and a hematoma to his left forehead. The patient presented with dysphagia and anterior neck swelling that progressed rapidly into airway compromise requiring endotracheal intubation. Emergent computed tomography revealed a large retropharyngeal hematoma, with active arterial extravasation that was thought to be arising from the thyrocervical trunk on the left. The hematoma measured approximately 6.7 cm transversely and 3.2 cm anteroposteriorly and extended from the level of the lower nasopharynx, down the neck into the retropharyngeal and danger space and into the mediastinum posterior to the esophagus, overall approximately 25 cm. The larynx was deviated anteriorly and there was esophageal compression. An emergent arteriogram and catheterization confirmed bleeding from branches of the ITA, and successful embolization was performed. It is important to recognize the ITA rupture as a potential etiology of an acute airway compromise. In emergent situations, while securing an airway is a priority, rapidly initiating diagnostic testing to confirm the diagnosis and arranging for arterial embolization can be life-saving.

  8. Splenic rupture following idiopathic rupture of the urinary bladder presenting as acute abdomen

    Directory of Open Access Journals (Sweden)

    Jurisic D

    2007-01-01

    Full Text Available Idiopathic rupture of the urinary bladder is an uncommon condition and represents less than 1% of all bladder rupture cases. In most of the cases the main etiological factor was heavy alcohol ingestion. A combined injury of the spleen and bladder is a very rare condition that is almost often associated with trauma and foreign bodies. In this paper we present the extremely rare clinical course of acute abdomen caused by a combined spontaneous intraperitoneal injury; spontaneous rupture of the urinary bladder and spleen. According to our opinion, spontaneous bladder rupture caused by bladder distension due to alcohol ingestion led to urinary ascites and abdominal distension. Finally, repeated minor abdominal blunt trauma during everyday life, to a moderately distended abdomen caused a spontaneous splenic rupture in the patient with abnormal coagulation studies.

  9. Effect of chemistry variations on the short-term rupture life and tensile properties of 20% cold-worked type 316 stainless steel

    International Nuclear Information System (INIS)

    Duncan, D.R.; Paxton, M.M.

    1977-01-01

    The effects of compositional variations on the rupture life of 20% cold-worked Type 316 stainless steel were investigated at 19-ksi (131-MPa) uniaxial tensile stress and at 1400 0 F (1033 K). Forty-nine different alloys were studied, with compositional variations from nominal in carbon, nitrogen, phosphorus, sulfur, boron, manganese, copper, silicon, molybdenum, cobalt, chromium and nickel. This alloy and cold-work level represents the duct and fuel cladding material choice for the first four core loadings of the Fast Flux Test Facility, a key element in the Liquid-Metal Fast Breeder Reactor Program. Tensile properties of four of the alloys were studied at temperatures from room temperature to 1600 0 F (1144 K). Boron, nitrogen, and molybdenum plus silicon additions significantly increased rupture life, while chromium and carbon additions decreased rupture life. Molybdenum plus silicon additions increased yield and ultimate strength and ductility at 1200 0 F (922 K) and below

  10. Proposition of Improved Methodology in Creep Life Extrapolation

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Park, Jae Young; Jang, Jin Sung

    2016-01-01

    To design SFRs for a 60-year operation, it is desirable to have the experimental creep-rupture data for Gr. 91 steel close to 20 y, or at least rupture lives significantly higher than 10"5 h. This requirement arises from the fact that, for the creep design, a factor of 3 times for extrapolation is considered to be appropriate. However, obtaining experimental data close to 20 y would be expensive and also take considerable time. Therefore, reliable creep life extrapolation techniques become necessary for a safe design life of 60 y. In addition, it is appropriate to obtain experimental longterm creep-rupture data in the range 10"5 ∼ 2x10"5 h to improve the reliability of extrapolation. In the present investigation, a new function of a hyperbolic sine ('sinh') form for a master curve in time-temperature parameter (TTP) methods, was proposed to accurately extrapolate the long-term creep rupture stress of Gr. 91 steel. Constant values used for each parametric equation were optimized on the basis of the creep rupture data. Average stress values predicted for up to 60 y were evaluated and compared with those of French Nuclear Design Code, RCC-MRx. The results showed that the master curve of the 'sinh' function was a wider acceptance with good flexibility in the low stress ranges beyond the experimental data. It was clarified clarified that the 'sinh' function was reasonable in creep life extrapolation compared with polynomial forms, which have been used conventionally until now.

  11. Proposition of Improved Methodology in Creep Life Extrapolation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Gon; Park, Jae Young; Jang, Jin Sung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    To design SFRs for a 60-year operation, it is desirable to have the experimental creep-rupture data for Gr. 91 steel close to 20 y, or at least rupture lives significantly higher than 10{sup 5} h. This requirement arises from the fact that, for the creep design, a factor of 3 times for extrapolation is considered to be appropriate. However, obtaining experimental data close to 20 y would be expensive and also take considerable time. Therefore, reliable creep life extrapolation techniques become necessary for a safe design life of 60 y. In addition, it is appropriate to obtain experimental longterm creep-rupture data in the range 10{sup 5} ∼ 2x10{sup 5} h to improve the reliability of extrapolation. In the present investigation, a new function of a hyperbolic sine ('sinh') form for a master curve in time-temperature parameter (TTP) methods, was proposed to accurately extrapolate the long-term creep rupture stress of Gr. 91 steel. Constant values used for each parametric equation were optimized on the basis of the creep rupture data. Average stress values predicted for up to 60 y were evaluated and compared with those of French Nuclear Design Code, RCC-MRx. The results showed that the master curve of the 'sinh' function was a wider acceptance with good flexibility in the low stress ranges beyond the experimental data. It was clarified clarified that the 'sinh' function was reasonable in creep life extrapolation compared with polynomial forms, which have been used conventionally until now.

  12. Traumatic Fundal Rupture of unscarred Uterus in a Primigravida ...

    African Journals Online (AJOL)

    Background: Uterine rupture is an infrequent but life threatening obstetric emergency. Rupture of previously scarred uterus is often encountered especially in multiparous women, but the traumatic rupture of an unscarred primigravid uterus as presented here is a relatively rare event. We report a case of rupture of an ...

  13. Effects on stress rupture life and tensile strength of tin additions to Inconel 718

    Science.gov (United States)

    Dreshfield, R. L.; Johnson, W.

    1982-01-01

    Because Inconel 718 represents a major use of columbium and a large potential source of columbium for aerospace alloys could be that of columbium derived from tin slags, the effects of tin additions to Inconel 718 at levels which might be typical of or exceed those anticipated if tin slag derived columbium were used as a melting stock were investigated. Tin was added to 15 pound Inconel 718 heats at levels varying from none added to approximately 10,000 ppm (1 wt%). Limited 1200 F stress rupture testing was performed at stresses from 68,000 to 115,000 psi and a few tensile tests were performed at room temperature, 800 and 1200 F. Additions of tin in excess of 800 ppm were detrimental to ductility and stress rupture life.

  14. Life cycle reliability assessment of new products—A Bayesian model updating approach

    International Nuclear Information System (INIS)

    Peng, Weiwen; Huang, Hong-Zhong; Li, Yanfeng; Zuo, Ming J.; Xie, Min

    2013-01-01

    The rapidly increasing pace and continuously evolving reliability requirements of new products have made life cycle reliability assessment of new products an imperative yet difficult work. While much work has been done to separately estimate reliability of new products in specific stages, a gap exists in carrying out life cycle reliability assessment throughout all life cycle stages. We present a Bayesian model updating approach (BMUA) for life cycle reliability assessment of new products. Novel features of this approach are the development of Bayesian information toolkits by separately including “reliability improvement factor” and “information fusion factor”, which allow the integration of subjective information in a specific life cycle stage and the transition of integrated information between adjacent life cycle stages. They lead to the unique characteristics of the BMUA in which information generated throughout life cycle stages are integrated coherently. To illustrate the approach, an application to the life cycle reliability assessment of a newly developed Gantry Machining Center is shown

  15. Reliability of COPVs Accounting for Margin of Safety on Design Burst

    Science.gov (United States)

    Murthy, Pappu L.N.

    2012-01-01

    In this paper, the stress rupture reliability of Carbon/Epoxy Composite Overwrapped Pressure Vessels (COPVs) is examined utilizing the classic Phoenix model and accounting for the differences between the design and the actual burst pressure, and the liner contribution effects. Stress rupture life primarily depends upon the fiber stress ratio which is defined as the ratio of stress in fibers at the maximum expected operating pressure to actual delivered fiber strength. The actual delivered fiber strength is calculated using the actual burst pressures of vessels established through burst tests. However, during the design phase the actual burst pressure is generally not known and to estimate the reliability of the vessels calculations are usually performed based upon the design burst pressure only. Since the design burst is lower than the actual burst, this process yields a much higher value for the stress ratio and consequently a conservative estimate for the reliability. Other complications arise due to the fact that the actual burst pressure and the liner contributions have inherent variability and therefore must be treated as random variables in order to compute the stress rupture reliability. Furthermore, the model parameters, which have to be established based on stress rupture tests of subscale vessels or coupons, have significant variability as well due to limited available data and hence must be properly accounted for. In this work an assessment of reliability of COPVs including both parameter uncertainties and physical variability inherent in liner and overwrap material behavior is made and estimates are provided in terms of degree of uncertainty in the actual burst pressure and the liner load sharing.

  16. Consistent creep and rupture properties for creep-fatigue evaluation

    International Nuclear Information System (INIS)

    Schultz, C.C.

    1978-01-01

    The currently accepted practice of using inconsistent representations of creep and rupture behaviors in the prediction of creep-fatigue life is shown to introduce a factor of safety beyond that specified in current ASME Code design rules for 304 stainless steel Class 1 nuclear components. Accurate predictions of creep-fatigue life for uniaxial tests on a given heat of material are obtained by using creep and rupture properties for that same heat of material. The use of a consistent representation of creep and rupture properties for a mininum strength heat is also shown to provide adequate predictions. The viability of using consistent properties (either actual or those of a minimum heat) to predict creep-fatigue life thus identifies significant design uses for the results of characterization tests and improved creep and rupture correlations

  17. Rupture of esophagus by compressed air.

    Science.gov (United States)

    Wu, Jie; Tan, Yuyong; Huo, Jirong

    2016-11-01

    Currently, beverages containing compressed air such as cola and champagne are widely used in our daily life. Improper ways to unscrew the bottle, usually by teeth, could lead to an injury, even a rupture of the esophagus. This letter to editor describes a case of esophageal rupture caused by compressed air.

  18. Consistent creep and rupture properties for creep-fatigue evaluation

    International Nuclear Information System (INIS)

    Schultz, C.C.

    1979-01-01

    The currently accepted practice of using inconsistent representations of creep and rupture behaviors in the prediction of creep-fatigue life is shown to introduce a factor of safety beyond that specified in current ASME Code design rules for 304 stainless steel Class 1 nuclear components. Accurate predictions of creep-fatigue life for uniaxial tests on a given heat of material are obtained by using creep and rupture properties for that same heat of material. The use of a consistent representation of creep and rupture properties for a minimum strength heat is also shown to provide reasonable predictions. The viability of using consistent properties (either actual or those of a minimum strength heat) to predict creep-fatigue life thus identifies significant design uses for the results of characterization tests and improved creep and rupture correlations. 12 refs

  19. Misdiagnosed Chest Pain: Spontaneous Esophageal Rupture

    Science.gov (United States)

    Inci, Sinan; Gundogdu, Fuat; Gungor, Hasan; Arslan, Sakir; Turkyilmaz, Atila; Eroglu, Atila

    2013-01-01

    Chest pain is one of themost common complaints expressed by patients presenting to the emergency department, and any initial evaluation should always consider life-threatening causes. Esophageal rupture is a serious condition with a highmortality rate. If diagnosed, successful therapy depends on the size of the rupture and the time elapsed between rupture and diagnosis.We report on a 41-year-old woman who presented to the emergency department complaining of left-sided chest pain for two hours. PMID:27122690

  20. LWR primary coolant pipe rupture test rig

    International Nuclear Information System (INIS)

    Yoshitoshi, Shyoji

    1978-01-01

    The rupture test rig for primary coolant pipes is constructed in the Japan Atomic Energy Research Institute to verify the reliability of the primary coolant pipes for both PWRs and BWRs. The planned test items consisted of reaction force test, restraint test, whip test, jet test and continuous release test. A pressure vessel of about 4 m 3 volume, a circulating pump, a pressurizer, a heater, an air cooler and the related instrumentation and control system are included in this test rig. The coolant test condition is 160 kg/cm 2 g, 325 deg C for PWR test, and 70 kg/cm 2 g, saturated water and steam for BWR test, 100 ton of test load for the ruptured pipe bore of 8B Schedule 160, and 20 lit/min. discharge during 20 h for continuous release of coolant. The maximum pit internal pressure was estimated for various pipe diameters and time under the PWR and BWR conditions. The spark rupturing device was adopted for the rupture mechanics in this test rig. The computer PANAFACOM U-300 is used for the data processing. This test rig is expected to operate in 1978 effectively for the improvement of reliability of LWR primary coolant pipes. (Nakai, Y.)

  1. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    International Nuclear Information System (INIS)

    Mondel, Prabath Kumar; Anand, Sunanda; Limaye, Uday S.

    2015-01-01

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described

  2. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Mondel, Prabath Kumar, E-mail: prabathmondel@gmail.com; Anand, Sunanda, E-mail: sunandaanand@gmail.com; Limaye, Uday S., E-mail: uslkem@gmail.com [Lilavati Hospital and Research Centre, Department of Interventional Neuroradiology (India)

    2015-08-15

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described.

  3. Reliability Growth in Space Life Support Systems

    Science.gov (United States)

    Jones, Harry W.

    2014-01-01

    A hardware system's failure rate often increases over time due to wear and aging, but not always. Some systems instead show reliability growth, a decreasing failure rate with time, due to effective failure analysis and remedial hardware upgrades. Reliability grows when failure causes are removed by improved design. A mathematical reliability growth model allows the reliability growth rate to be computed from the failure data. The space shuttle was extensively maintained, refurbished, and upgraded after each flight and it experienced significant reliability growth during its operational life. In contrast, the International Space Station (ISS) is much more difficult to maintain and upgrade and its failure rate has been constant over time. The ISS Carbon Dioxide Removal Assembly (CDRA) reliability has slightly decreased. Failures on ISS and with the ISS CDRA continue to be a challenge.

  4. Restoration of ankle joint, quality of life dynamics and assessment of achilles tendon rupture consequences

    Directory of Open Access Journals (Sweden)

    V.V. Vitomskyi

    2017-11-01

    Full Text Available Aim: to investigate the dynamics of restoration of the amplitude of motion in the ankle joint, the quality of life and to assess the effects of the breakdown of the Achilles tendon. Material: patients (n=59, of which n=30 – the main group and n=29 – the control group were examined at 4, 8 and 16 weeks after surgery. Indicators registered with the help of: goniometry; the Achilles tendon Total Rupture Score; the scale of an assessment of consequences and results of Leppilahti implications. Results: the decrease of the total amplitude of the motion in the ankle joint takes place due to the deficiency of the amplitude of the dorsal flexion. At the end of the study the dorsal flexion rates were significantly better among the patients of main group. In particular, its deficit was 3.2 ± 1.85° in the main group and 6.8 ± 2.06° in the control group. The final total score Me (25; 75 was also better according to the questionnaire of the Achilles tendon Total Rupture Score: 82 (78; 84 points against 74 (72; 77 points (p <0.01. An assessment of consequences according to the Leppilahti score was 83.8 ± 8.58 points in the main group and 70.7 ± 10.58 points in the control group (p <0.01. Conclusions: means of physical rehabilitation help recover the amplitude of movement in the ankle joint, improve the quality of life and the effects after the rupture of the Achilles tendon. The correct methodological approach and combination of tools further improves the results.

  5. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  6. Evolution of Machine Reliability and Life and Economics of Operational Use

    Directory of Open Access Journals (Sweden)

    Młynarski Stanisław

    2016-12-01

    Full Text Available The article presents new assumptions for reliability and life of machines, resulting from the development of technology. The innovative approach to reliability and life design as well as warranty duration planning is presented on an example of vehicle reliability characteristics. A new algorithm is proposed for the replacement of repairable objects costs by the price of life and reliability of new unrepairable ones. For the planning of the life of innovative machines, an effective method of technical progress rate determination is proposed. In conclusion, necessary modifications of machine and vehicle use systems, resulting from technology evolution and technical progress, are indicated. Finally, recommendations and directions of indispensable research in engineering and management of technical means of production are formulated.

  7. Validation of statistical models for creep rupture by parametric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, J., E-mail: john.bolton@uwclub.net [65, Fisher Ave., Rugby, Warks CV22 5HW (United Kingdom)

    2012-01-15

    Statistical analysis is an efficient method for the optimisation of any candidate mathematical model of creep rupture data, and for the comparative ranking of competing models. However, when a series of candidate models has been examined and the best of the series has been identified, there is no statistical criterion to determine whether a yet more accurate model might be devised. Hence there remains some uncertainty that the best of any series examined is sufficiently accurate to be considered reliable as a basis for extrapolation. This paper proposes that models should be validated primarily by parametric graphical comparison to rupture data and rupture gradient data. It proposes that no mathematical model should be considered reliable for extrapolation unless the visible divergence between model and data is so small as to leave no apparent scope for further reduction. This study is based on the data for a 12% Cr alloy steel used in BS PD6605:1998 to exemplify its recommended statistical analysis procedure. The models considered in this paper include a) a relatively simple model, b) the PD6605 recommended model and c) a more accurate model of somewhat greater complexity. - Highlights: Black-Right-Pointing-Pointer The paper discusses the validation of creep rupture models derived from statistical analysis. Black-Right-Pointing-Pointer It demonstrates that models can be satisfactorily validated by a visual-graphic comparison of models to data. Black-Right-Pointing-Pointer The method proposed utilises test data both as conventional rupture stress and as rupture stress gradient. Black-Right-Pointing-Pointer The approach is shown to be more reliable than a well-established and widely used method (BS PD6605).

  8. Composite Overwrap Pressure Vessels: Mechanics and Stress Rupture Lifting Philosophy

    Science.gov (United States)

    Thesken, John C.; Murthy, Pappu L. N.; Phoenix, S. L.

    2009-01-01

    The NASA Engineering and Safety Center (NESC) has been conducting an independent technical assessment to address safety concerns related to the known stress rupture failure mode of filament wound pressure vessels in use on Shuttle and the International Space Station. The Shuttle s Kevlar-49 (DuPont) fiber overwrapped tanks are of particular concern due to their long usage and the poorly understood stress rupture process in Kevlar-49 filaments. Existing long term data show that the rupture process is a function of stress, temperature and time. However due to the presence of load sharing liners and the complex manufacturing procedures, the state of actual fiber stress in flight hardware and test articles is not clearly known. Indeed nonconservative life predictions have been made where stress rupture data and lifing procedures have ignored the contribution of the liner in favor of applied pressure as the controlling load parameter. With the aid of analytical and finite element results, this paper examines the fundamental mechanical response of composite overwrapped pressure vessels including the influence of elastic plastic liners and degraded/creeping overwrap properties. Graphical methods are presented describing the non-linear relationship of applied pressure to Kevlar-49 fiber stress/strain during manufacturing, operations and burst loadings. These are applied to experimental measurements made on a variety of vessel systems to demonstrate the correct calibration of fiber stress as a function of pressure. Applying this analysis to the actual qualification burst data for Shuttle flight hardware revealed that the nominal fiber stress at burst was in some cases 23 percent lower than what had previously been used to predict stress rupture life. These results motivate a detailed discussion of the appropriate stress rupture lifing philosophy for COPVs including the correct transference of stress rupture life data between dissimilar vessels and test articles.

  9. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  10. Mathematical Methods in Survival Analysis, Reliability and Quality of Life

    CERN Document Server

    Huber, Catherine; Mesbah, Mounir

    2008-01-01

    Reliability and survival analysis are important applications of stochastic mathematics (probability, statistics and stochastic processes) that are usually covered separately in spite of the similarity of the involved mathematical theory. This title aims to redress this situation: it includes 21 chapters divided into four parts: Survival analysis, Reliability, Quality of life, and Related topics. Many of these chapters were presented at the European Seminar on Mathematical Methods for Survival Analysis, Reliability and Quality of Life in 2006.

  11. Technique for the residual life assessment of high temperature components based on creep-rupture testing on welded miniature specimens

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Guardamagna, C.; Moscotti, L.; Ranzani, L. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-06-01

    Following the present trend in the development of advanced methodologies for residual life assessment of high temperature components operating in power plants, particularly in non destructive methods, a testing technique has been set up at ENEL-CRAM based on creep-rupture testa in an argon on welded miniature specimens. Five experimental systems for creep-rupture tests in an argon atmosphere have been set up which include high accuracy systems, vacuum chambers and exrwnsometer devices. With the aim of establishing and validating the suitability of the experimental methodology, creep-rupture and interrupted creep testing programmes have been performed on miniature specimens (2 mm diameter and 10 mm gauge lenght). On the basis of experience gathered by various European research laboratories, a miniature specimen construction procedure has been developed using a laser welding technique for joining threaded heads to sample material. Low alloy ferritic steels, such as virgin 2.25CrlMo, 0.5Cr 0.5Mo 0.25V, and IN 738 superalloy miniature specimens have been investigated and the results, compared with those from standard specimens, show a regular trend in deformation vs time. Additional efforts to provide guidelines for material sampling from each plant component will be required in order to reduce uncertainties in residual life prediction.

  12. Evaluation of creep-fatigue life prediction methods for low-carbon/nitrogen-added SUS316

    International Nuclear Information System (INIS)

    Takahashi, Yukio

    1998-01-01

    Low-carbon/medium nitrogen 316 stainless steel called 316FR is a principal candidate for the high-temperature structural materials of a demonstration fast reactor plant. Because creep-fatigue damage is a dominant failure mechanism of the high-temperature materials subjected to thermal cycles, it is important to establish a reliable creep-fatigue life prediction method for this steel. Long-term creep tests and strain-controlled creep-fatigue tests have been conducted at various conditions for two different heats of the steel. In the constant load creep tests, both materials showed similar creep rupture strength but different ductility. The material with lower ductility exhibited shorter life under creep-fatigue loading conditions and correlation of creep-fatigue life with rupture ductility, rather than rupture strength, was made clear. Two kinds of creep-fatigue life prediction methods, i.e. time fraction rule and ductility exhaustion method were applied to predict the creep-fatigue life. Accurate description of stress relaxation behavior was achieved by an addition of 'viscous' strain to conventional creep strain and only the latter of which was assumed to contribute to creep damage in the application of ductility exhaustion method. The current version of the ductility exhaustion method was found to have very good accuracy in creep-fatigue life prediction, while the time fraction rule overpredicted creep-fatigue life as large as a factor of 30. To make a reliable estimation of the creep damage in actual components, use of ductility exhaustion method is strongly recommended. (author)

  13. Effect of Squareness of Initial γ' Precipitates on Creep-Rupture Life of a Ni-Base Single Crystal Superalloy at 760/982 °C

    Science.gov (United States)

    Shi, Zhenbin; Peng, Zhifang; Luo, Yushi; Xie, Hongji; Jin, Haipeng; Zhao, Yunsong; Mei, Qingsong

    2018-05-01

    An approach to determination of squareness of initial γ' precipitates (S 2D) is proposed to evaluate its effect on creep-rupture life (t r) of nickel-base single crystal (SC) superalloys. It is found that the 760/982 °C rupture life varied with the change in regional S 2D caused by redistribution of W when 1st-step aging temperature changed in full heat treatment on superalloy DD83 investigated. The longest creep-rupture life occurred at the highest value/the lowest difference in S 2D in the interdendritic regions/between the typical dendritic regions in DD83. It is also found that S 2D is a weighted function of the area fraction (F 2D), spacing (h), and size (d) of γ' precipitates and is closely related to t r in a series of SC superalloys. In addition, the variation of S 2D with F 2D (here, thermodynamic mole fraction is approximately expressed by F 2D) through lattice misfit (δ) in the SC superalloys with F 2D ranging from 60 to 75 pct is well correlated. Therefore, to reveal and to better understand these relationships and correlations may help to optimize the phase variables in order to achieve a long rupture life of SC superalloys. In addition, functions to reveal the interrelationships of F 2D, volume fraction (F 3D), S 2D, and cuboidness (S 3D) of initial γ' precipitates are derived considering their shape changes. All of these are hoped to be helpful in practical applications and in understanding the true meaning of the related variables.

  14. Definitive diagnosis of breast implant rupture using magnetic resonance imaging.

    Science.gov (United States)

    Ahn, C Y; Shaw, W W; Narayanan, K; Gorczyca, D P; Sinha, S; Debruhl, N D; Bassett, L W

    1993-09-01

    Breast implant rupture is an important complication of augmented and reconstructed breasts. Although several techniques such as mammography, xeromammography, ultrasound, thermography, and computed tomographic (CT) scanning have been proven to be useful to detect implant rupture, they have several disadvantages and lack specificity. In the current study, we have established magnetic resonance imaging (MRI) as a definitive, reliable, and reproducible technique to diagnose both intracapsular and extracapsular ruptures. The study was conducted in 100 symptomatic patients. Our imaging parameters were able to identify ruptures in implants with silicone shells. All the ruptures showed the presence of wavy lines, free-floating silicone shell within the gel ("free-floating loose-thread sign" or "linguine sign"). We had a 3.75 percent incidence of false-positive and false-negative results. The sensitivity for detection of silicone implant rupture was 76 percent, with a specificity of 97 percent. In addition, we also were able to identify the artifacts that may interfere with the definitive diagnosis of implant rupture.

  15. The stress rupture properties of austenitic steel weld metals

    International Nuclear Information System (INIS)

    Wood, D.S.

    Elevated temperature stress rupture data on Mo containing and Mo free austenitic weld metals have been collected from French, Dutch, German and UK sources and the results analysed. The stress rupture strength of Mo containing weld metal is significantly higher than that of Mo free weld metal. At 10,000h the rupture strength of Mo containing weld metal is higher than that of Type 316 steel whereas the Mo free weld metal is about 20% lower than that of Type 304 steel. Austenitic weld metal can give low stress rupture ductility values. It is concluded that there are insufficient data to permit reliable extrapolations to long times and it is recommended that long term tests are performed to overcome this situation

  16. Liver Hydatid Cyst with Transdiaphragmatic Rupture and Lung Hydatid Cyst Ruptured into Bronchi and Pleural Space

    International Nuclear Information System (INIS)

    Arıbaş, Bilgin Kadri; Dingil, Gürbüz; Köroğlu, Mert; Üngül, Ümit; Zaralı, Aliye Ceylan

    2011-01-01

    The aim of this case study is to present effectiveness of percutaneous drainage as a treatment option of ruptured lung and liver hydatid cysts. A 65-year-old male patient was admitted with complicated liver and lung hydatid cysts. A liver hydatid cyst had ruptured transdiaphragmatically, and a lung hydatid cyst had ruptured both into bronchi and pleural space. The patient could not undergo surgery because of decreased respiratory function. Both cysts were drained percutaneously using oral albendazole. Povidone–iodine was used to treat the liver cyst after closure of the diaphragmatic rupture. The drainage was considered successful, and the patient had no recurrence of signs and symptoms. Clinical, laboratory, and radiologic recovery was observed during 2.5 months of catheterization. The patient was asymptomatic after catheter drainage. No recurrence was detected during 86 months of follow-up. For inoperable patients with ruptured liver and lung hydatid cysts, percutaneous drainage with oral albendazole is an alternative treatment option to surgery. The percutaneous approach can be life-saving in such cases.

  17. Ultra Reliable Closed Loop Life Support for Long Space Missions

    Science.gov (United States)

    Jones, Harry W.; Ewert, Michael K.

    2010-01-01

    Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.

  18. A Case of Post Myocardial Infarction Papillary Muscle Rupture.

    Science.gov (United States)

    Anuwatworn, Amornpol; Milnes, Christopher; Kumar, Vishesh; Raizada, Amol; Nykamp, Verlyn; Stys, Adam

    2016-06-01

    Papillary muscle rupture is a rare, life-threatening post myocardial infarction mechanical complication. Without surgical intervention, prognosis is very poor. Clinicians need to recognize this complication early, as prompt therapy is crucial. We present a case of inferior ST elevation myocardial infarction complicated by posteromedial papillary muscle rupture resulting in severe acute mitral regurgitation (flail anterior mitral leaflet), acute pulmonary edema and cardiogenic shock. In our patient, a new mitral regurgitation murmur suggested this mechanical complication. Complete disruption of papillary muscle was visualized by transesophageal echocardiography. This case illustrates the importance of good physical examination for early diagnosis of papillary muscle rupture, so that life-saving treatment can be administered without delay.

  19. Characterize kinematic rupture history of large earthquakes with Multiple Haskell sources

    Science.gov (United States)

    Jia, Z.; Zhan, Z.

    2017-12-01

    Earthquakes are often regarded as continuous rupture along a single fault, but the occurrence of complex large events involving multiple faults and dynamic triggering challenges this view. Such rupture complexities cause difficulties in existing finite fault inversion algorithms, because they rely on specific parameterizations and regularizations to obtain physically meaningful solutions. Furthermore, it is difficult to assess reliability and uncertainty of obtained rupture models. Here we develop a Multi-Haskell Source (MHS) method to estimate rupture process of large earthquakes as a series of sub-events of varying location, timing and directivity. Each sub-event is characterized by a Haskell rupture model with uniform dislocation and constant unilateral rupture velocity. This flexible yet simple source parameterization allows us to constrain first-order rupture complexity of large earthquakes robustly. Additionally, relatively few parameters in the inverse problem yields improved uncertainty analysis based on Markov chain Monte Carlo sampling in a Bayesian framework. Synthetic tests and application of MHS method on real earthquakes show that our method can capture major features of large earthquake rupture process, and provide information for more detailed rupture history analysis.

  20. Developing Ultra Reliable Life Support for the Moon and Mars

    Science.gov (United States)

    Jones, Harry W.

    2009-01-01

    Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

  1. In-reactor creep rupture of 20% cold-worked AISI 316 stainless steel

    International Nuclear Information System (INIS)

    Lovell, A.J.; Chin, B.A.; Gilbert, E.R.

    1981-01-01

    Results of an experiment designed to measure in-reactor stress-to-rupture properties of 20% cold-worked AISI 316 stainless steel are reported. The in-reactor rupture data are compared with postirradiation and unirradiated test results. In-reactor rupture lives were found to exceed rupture predictions of postirradiation tests. This longer in-reactor rupture life is attributed to dynamic point defect generation which is absent during postirradiation testing. The in-reactor stress-to-rupture properties are shown to be equal to or greater than the unirradiated material stress-to-rupture properties for times up to 7000 h. (author)

  2. Creep Rupture Analysis and Life Estimation of 1.25Cr-0.5Mo, 2.25Cr-1Mo and Modified 9Cr-1Mo Steel: A Comparative Study

    Science.gov (United States)

    Roy, Prabir Kumar

    2018-04-01

    This paper highlights a comparative assessment of creep life of 1.25Cr-0.5Mo, 2.25Cr-1Mo and modified 9Cr-1Mo steels based on accelerated creep rupture tests. Creep rupture test data have been analysed and creep life of the above mentioned materials have been assessed using Larson Miller parameter at the stress levels of 60 and 42 MPa for different temperatures. Limiting steam temperatures for minimum design life of 105 h at 42 and 60 MPa for the above mentioned steels have also been calculated. Microstructural studies for the three above mentioned steels are also done.

  3. Anisotropic stress rupture properties of the nickel-base single crystal superalloy SRR99

    International Nuclear Information System (INIS)

    Han, G.M.; Yu, J.J.; Sun, Y.L.; Sun, X.F.; Hu, Z.Q.

    2010-01-01

    The influence of orientation on the stress rupture properties of a single crystal superalloy SRR99 was investigated at temperatures of 760 and 1040 deg. C. It is found that the creep anisotropic behaviour is pronounced at the lower temperature of 760 deg. C and the stress rupture life ranks in the order [0 0 1] > [1 1 1] > [0 1 1]. Despite the anisotropy of stress rupture life is evidently reduced at the higher temperature, the [1 1 1] orientation exhibits the longest life. At 760 deg. C, EBSD (electron back scattered diffraction) was adopted to measure the lattice rotation and the deduced results indicate that the dominant slip systems are {1 1 1} during stress rupture test. At 1040 deg. C, the ranking order of the stress rupture life is [1 1 1] > [0 0 1] > [0 1 1] and the single crystal close to [0 1 1] orientation still shows the poorest life. In the [0 0 1] and [1 1 1] samples, regular γ' raft structure is formed compared with [0 1 1] samples. Further observations made by TEM investigations reveal the underlying deformation mechanisms for crystals with orientations near [0 0 1], [0 1 1] and [1 1 1] under two test conditions.

  4. Traumatic diaphragmatic ruptures: clinical presentation, diagnosis and surgical approach in adults

    Directory of Open Access Journals (Sweden)

    Hofmann, Sabine

    2012-01-01

    Full Text Available Objective: Traumatic diaphragmatic injuries are rare, but potentially life-threatening due to herniation of abdominal organs into the pleural cavities. They can be easily overlooked on initial diagnostics and a high index of suspicion is required. The aim of this retrospective study was to analyze the clinical presentation, diagnostic methods and surgical management of patients with diaphragmatic rupture at our institution. Methods: A retrospective study was performed to analyze our experience with patients suffering from traumatic diaphragmatic rupture. Charts were reviewed for sex, age, side-location, concomitant injuries, time-to-diagnosis, diagnostic methods, surgical approach and outcome. Results: Fourteen patients (median age: 46 yrs, range 18–71, 9 male, 5 female with diaphragmatic injuries (left side: 10, right side: 4 were treated between July 2003 and September 2011. Mechanism of injury was a penetrating trauma (14%, blunt trauma (50% and others (36%. Associated abdominal injuries included spleen rupture (n=3, liver laceration (n=2, abdominal wall laceration (n=2 and gastric perforation (n=1. Computed tomography was the most sensitive diagnostic method. All patients underwent trans-abdominal repair of the diaphragmatic defect (direct suture: 10, prosthetic mesh insertion: 4. Associated abdominal procedures included splenectomy (n=3, liver packing (n=2, abdominal wall reconstruction (n=2 and partial gastric resection (n=1. Morbidity and hospital mortality rate were 36% and 0%, respectively. Median postoperative hospital stay was 17 days (range: 7–40 days. Conclusion: Morbidity and mortality of diaphragmatic ruptures are mainly determined by associated injuries or complications of diaphragmatic herniation like incarceration of viscera or lung failure. Early diagnosis helps to prevent severe complications. Spiral CT-scan is the most reliable tool for acute diagnosis of diaphragmatic rupture and associated visceral lacerations

  5. Abdominal wall abscess secondary to spontaneous rupture of pyogenic liver abscess

    Directory of Open Access Journals (Sweden)

    Maurizio Zizzo

    2016-01-01

    Conclusion: Pyogenic liver abscess is a serious and life-threatening illness. Abscess rupture might occur. Many authors consider this complication a surgical emergency, but the site of abscess rupture changes the clinical history of the disease: in case of free rupture into the peritoneum, emergency surgery is mandatory, while a rupture localized in neighboring tissues or organs can be successfully treated by a combination of systemic antibiotics and fine needle aspiration and/or percutaneous drainage of the abscess.

  6. Assessment of Creep Deformation, Damage, and Rupture Life of 304HCu Austenitic Stainless Steel Under Multiaxial State of Stress

    Science.gov (United States)

    Sahoo, K. C.; Goyal, Sunil; Parameswaran, P.; Ravi, S.; Laha, K.

    2018-03-01

    The role of the multiaxial state of stress on creep deformation and rupture behavior of 304HCu austenitic stainless steel was assessed by performing creep rupture tests on both smooth and notched specimens of the steel. The multiaxial state of stress was introduced by incorporating circumferential U-notches of different root radii ranging from 0.25 to 5.00 mm on the smooth specimens of the steel. Creep tests were carried out at 973 K over the stress range of 140 to 220 MPa. In the presence of notch, the creep rupture strength of the steel was found to increase with the associated decrease in rupture ductility. Over the investigated stress range and notch sharpness, the strengthening was found to increase drastically with notch sharpness and tended toward saturation. The fractographic studies revealed the mixed mode of failure consisting of transgranular dimples and intergranular creep cavitation for shallow notches, whereas the failure was predominantly intergranular for relatively sharper notches. Detailed finite element analysis of stress distribution across the notch throat plane on creep exposure was carried out to assess the creep failure of the material in the presence of notch. The reduction in von-Mises stress across the notch throat plane, which was greater for sharper notches, increased the creep rupture strength of the material. The variation in fracture behavior of the material in the presence of notch was elucidated based on the von-Mises, maximum principal, and hydrostatic stresses. Electron backscatter diffraction analysis of creep strain distribution across the notch revealed localized creep straining at the notch root for sharper notches. A master curve for predicting creep rupture life under the multiaxial state of stress was generated considering the representative stress having contributions from both the von-Mises and principal stress components of the stress field in the notch throat plane. Rupture ductility was also predicted based on the

  7. Improvement of creep-rupture properties by serrated grain boundaries in high-tungsten cobalt-base superalloys

    International Nuclear Information System (INIS)

    Tanaka, Manabu

    1993-01-01

    The improvement of creep-rupture properties by serrated grain boundaries was investigated using cobalt-base superalloys containing about 14 to 20 wt.% tungsten at 1089 and 1311 K. Serrated grain boundaries improved both the rupture life and the ductility, especially under lower stresses at 1089 K. The increase in rupture life was larger in the alloys containing a larger amount of W. Ductile grain boundary fracture surfaces, which involved dimple patterns and grain boundary ledges, were observed in the specimens with serrated grain boundaries whereas brittle grain boundary facets were observed in the specimens with normal straight grain boundaries ruptured at 1089 K. The strengthening by serrated grain boundaries was also effective at 1311 K, but there was little difference in rupture life between the specimens with serrated grain boundaries and those with straight grain boundaries under lower stresses, since serrated grain boundaries developed also in the specimens with straight grain boundaries according to grain boundary precipitates forming during creep at 1311 K. The increase in W content of the alloys led to the increase in rupture life of the specimens with serrated grain boundaries at 1089 and 1311 K. (orig.) [de

  8. A Critique of a Phenomenological Fiber Breakage Model for Stress Rupture of Composite Materials

    Science.gov (United States)

    Reeder, James R.

    2010-01-01

    Stress rupture is not a critical failure mode for most composite structures, but there are a few applications where it can be critical. One application where stress rupture can be a critical design issue is in Composite Overwrapped Pressure Vessels (COPV's), where the composite material is highly and uniformly loaded for long periods of time and where very high reliability is required. COPV's are normally required to be proof loaded before being put into service to insure strength, but it is feared that the proof load may cause damage that reduces the stress rupture reliability. Recently, a fiber breakage model was proposed specifically to estimate a reduced reliability due to proof loading. The fiber breakage model attempts to model physics believed to occur at the microscopic scale, but validation of the model has not occurred. In this paper, the fiber breakage model is re-derived while highlighting assumptions that were made during the derivation. Some of the assumptions are examined to assess their effect on the final predicted reliability.

  9. Creep life assessment of Mod.9Cr-1Mo steel. Pt. 1. Quantitative evaluation of microstructural damage in creep rupture specimens

    International Nuclear Information System (INIS)

    Sawada, Kota; Maruyama, Kouichi; Komine, Ryuji; Nagae, Yuji

    1997-03-01

    Several microstructural changes take place in a material during the course of creep. These changes can be a measure of creep life consumption. In this paper, microstructural changes in Mod.9Cr-1Mo steel were studied in order to examine their ability as the measure of creep life consumption. Macroscopic structural changes, such as void growth, rotation of lath structure toward the tensile axis and elongation of grains, are evident only in the necked portion of ruptured specimens. These macroscopic structural changes are not useful for creep life assessment. Lath width increases and dislocation density within lath decreases with increasing creep duration. These changes in dislocation substructure start in the early stage of creep life, and cause the increase of strain rate in the tertiary creep stage. The lath width and the dislocation density reach a stationary value before rupture. The stationary values are independent of temperature, and uniquely related to creep stress normalized by shear modulus. The extent of these microstructural changes are greater at lower stresses under which the material is practically used. These facts suggest that the lath width and the dislocation density within lath can be a useful measure of creep life consumption. Hardness of crept specimens is closely related to the lath width and the dislocation density within lath. The changes of these microstructural features can be evaluated by the measurement of hardness. (author)

  10. Effect of sodium on the creep-rupture behavior of type 304 stainless steel

    International Nuclear Information System (INIS)

    Natesan, K.; Chopra, O.K.; Kassner, T.F.

    1976-01-01

    Uniaxial creep-rupture data have been obtained for Type 304 stainless steel in the solution-annealed condition and after exposure to a flowing sodium environment at temperatures of 700, 650, and 600 0 C.The specimens were exposed to sodium for time periods between 120 and 5012 h to produce carbon penetration depths of approximately 0.010, 0.020, and 0.038 cm in the steel. Results showed that, as the depth of carbon penetration and the average carbon concentration in the steel increase, the rupture life increases and the minimum creep rate decreases. Creep correlations that relate rupture life, minimum creep rate, and time-to-tertiary creep were developed for the steel in both the solution-annealed and sodium-exposed conditions. Isochronous stress-creep strain curves and results on the calculations of the stress levels for 1 percent creep strain and long-term rupture life are also presented. 11 fig

  11. Validation and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women.

    Science.gov (United States)

    Abay, Halime; Kaplan, Sena

    2016-04-01

    There are a limited number of menopause-specific quality-of-life scales for the Turkish population. This study was conducted to evaluate the validity and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women. The study group was comprised of 250 postmenopausal women who applied to a training and research hospital's menopause clinic in Turkey. A survey form and the Turkish Utian quality-of-Life Scale were used to collect data, and the Turkish version of Short Form-36 was used to evaluate reliability with an equivalent form. Language-validity, content-validity, and construct-validity methods were used to assess the validity of the scale, and Cronbach's α coefficient calculation and the equivalent-form reliability methods were used to assess the reliability of the scale. The Turkish Utian Quality-of-Life Scale was determined to be a valid and reliable instrument for measuring the quality of life of postmenopausal women. Confirmatory factor analysis demonstrates that the instrument fits well with 23 items and a four-factor model. The Cronbach's α coefficient for the quality-of-life domains were as follows: 0.88 overall, 0.79 health, 0.78 emotional, 0.76 sexual, and 0.75 occupational. Reliability of the instrument was confirmed through significant correlations between scores on the Turkish version of the Utian Quality-of-Life Scale and the Turkish version of the Short Form-36 (r = 0.745, P measuring quality of life during menopause.

  12. Reliability and service life of wood structures and buildings

    Directory of Open Access Journals (Sweden)

    Zdeňka Havířová

    2005-01-01

    Full Text Available Service life of constructions and buildings of wood is dependent on temperature and moisture conditions in layers of the building cladding where the wood framework is built in. Temperature/moisture conditions or the corresponding equilibrium moisture content (EMC of the construction show considerable effects on the functional reliability of the whole building from the viewpoint of mechanical resistance and stability (ER1, energy savings and thermal protection (ER6 and hygiene, health and environment protection (ER3. To ensure the reliability of constructions and buildings for the period of their supposed service life a more profound analysis of constructions is necessary from the aspect of a global thermal/technical evaluation.

  13. Applications of majorization and Schur functions in reliability and life testing

    International Nuclear Information System (INIS)

    Proschan, F.

    1975-01-01

    This is an expository paper presenting basic definitions and properties of majorization and Schur functions, and displaying a variety of applications of these concepts in reliability prediction and modelling, and in reliability inference and life testing

  14. The extrapolation of creep rupture data by PD6605 - An independent case study

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, J., E-mail: john.bolton@uwclub.net [65 Fisher Avenue, Rugby, Warks CV22 5HW (United Kingdom)

    2011-04-15

    The worked example presented in BSI document PD6605-1:1998, to illustrate the selection, validation and extrapolation of a creep rupture model using statistical analysis, was independently examined. Alternative rupture models were formulated and analysed by the same statistical methods, and were shown to represent the test data more accurately than the original model. Median rupture lives extrapolated from the original and alternative models were found to diverge widely under some conditions of practical interest. The tests prescribed in PD6605 and employed to validate the original model were applied to the better of the alternative models. But the tests were unable to discriminate between the two, demonstrating that these tests fail to ensure reliability in extrapolation. The difficulties of determining when a model is sufficiently reliable for use in extrapolation are discussed and some proposals are made.

  15. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  16. Value of the quantity and distribution of subarachnoid haemorrhage on CT in the localization of ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Karttunen, A.I.; Jartti, P.H.; Haapea, M.; Ukkola, V.A.; Sajanti, J.

    2003-01-01

    Computed tomography (CT) is the 'gold standard' for detecting subarachnoid haemorrhage (SAH) and digital subtraction angiography (DSA) for visualising the vascular pathology. We studied retrospectively 180 patients with subarachnoid haemorrhage (SAH) who underwent first non-enhanced computed tomography (CT), then digital subtraction angiography (DSA) and finally operative aneurysm clipping. Our aim was to assess if the location of the ruptured aneurysm could be predicted on the basis of the quantity and distribution of haemorrhage on the initial CT scan. 180 patients with SAH were retrospectively studied. All the CT and DSA examinations were performed at the same hospital. CT was performed within 24 hours after the initial haemorrhage. DSA was performed alter the CT, within 48 hours after the initial haemorrhage. Two neuroradiologists, blind to the DSA results, analysed and scored independently the quantity and distribution of the haemorrhage and predicted the site of the ruptured aneurysm on the basis of the non-enhanced CT. DSA provided the location of the ruptured aneurysm. All the patients were operated upon, and the location of the ruptured aneurysm was determined. The overall reliability value (r,-value) between the two neuroradiologists for locating all ruptured aneurysms was 0.780. The corresponding value for the right MCA was 0.911, that for the left MCA 0.877 and that for the AcoA 0.736. Not all of the rc-values were calculated, either because the location of the rupture was constant or because the number of ruptures in the vessel was too small. Subarachnoid haemorrhage with a parenchymal hematoma is an excellent predictor of the site of the ruptured aneurysm with a statistical significance of p = 0.003. The quantity and pattern of the blood clot an CT within the day of onset of SAH is a reliable and quick cool for locating a ruptured MCA or AcoA aneurysm. It is not, however, reliable for locating other ruptured aneurysms. Subarachnoid haemorrhage with a

  17. Hemoperitoneum from corpus luteum rupture in patients with aplastic anemia.

    Science.gov (United States)

    Wang, Huaquan; Guo, Lifang; Shao, Zonghong

    2015-01-01

    Aplastic anemia is a rare hematopoietic stem-cell disorder that results in pancytopenia and hypocellular bone marrow. Women with aplastic anemia usually are at increased risk of corpus luteum rupture due to thrombocytopenia and infection. Here we report two cases had hemoperitoneum from corpus luteum rupture in patients with aplastic anemia in our center. Case 1 involved two episodes of hemoperitoneum resulting from rupture of the corpus luteum in a 23-year-old unmarried female with severe aplastic anemia. This patient was managed conservatively with platelet and packed red cell transfusion. Case 2 involved two episodes of hemoperitoneum resulting from rupture of the corpus luteum in a 33-year-old married patient with aplastic anemia. Emergency laparoscopy revealed massive hemoperitoneum. Bilateral salpingo-oophorectomy were performed successively with platelet and packed red cell transfusion. Hemoperitoneum resulting from a ruptured corpus luteum is a life-threatening condition in patients with aplastic anemia. Prompt and appropriate evaluation of corpus luteum rupture and emergent therapy are needed.

  18. Life-threatening rupture of a renal angiomyolipoma in a patient taking over-the-counter horse chestnut seed extract.

    LENUS (Irish Health Repository)

    Snow, Aisling

    2011-02-09

    BACKGROUND: Alternative medical therapies are increasingly being prescribed due to their good safety profile and perceived limited side effects. They are often unregulated and prescribed over the counter. One such medication is horse chestnut seed extract (HCSE), which is used for the treatment of chronic venous insufficiency and is known to affect blood coagulation. Angiomyolipoma (AML) is a benign fat-containing mesenchymal tumor of the kidney. It is often found incidentally and in most cases can be managed conservatively. Rupture of the kidney with hemorrhage is a well-known complication that may be serious and life-threatening. Known risk factors for hemorrhage include anticoagulation as well as pregnancy, increased size of the lesion, high lesion vascularity, and aneurysm formation within the tumor. OBJECTIVES: The aim is to raise awareness of potential HCSE-induced anticoagulation, including, as in the case presented, acute renal AML hemorrhage. CASE REPORT: The case of a patient taking HCSE for venous insufficiency is presented. The patient suffered a life-threatening rupture of the kidney in the presence of known renal AML. She underwent emergency embolization with a successful outcome. Because HCSE-containing products are thought to be generally safe in the treatment of chronic venous insufficiency, it is important to be mindful of their potential anticoagulant properties and, therefore, their relative contraindication both in patients taking other anticoagulants and those with known renal AML. CONCLUSION: We demonstrate a potentially life-threatening association between HSCE-containing products and renal AML, highlighting the risk associated with HSCE-induced anticoagulation.

  19. Creep-rupture behavior of iron superalloys in high-pressure hydrogen

    Science.gov (United States)

    Bhattacharyya, S.; Peterman, W.

    1984-01-01

    The creep-rupture properties of five iron-base and one cobalt-base high temperature alloys were investigated to assess the feasibility of using the alloys as construction materials in a Stirling engine. The alloys were heat treated and hardness measurements were taken. Typical microstructures of the alloys are shown. The creep-rupture properties of the alloys were determined at 760 and 815 C in 15.0 MPa H2 for 200 to 1000 hours. Plots of rupture life versus stress for the six superalloys are presented along with creep strain-time plots.

  20. Effects of phosphorus on the δ-Ni3Nb phase precipitation and the stress rupture properties in alloy 718

    International Nuclear Information System (INIS)

    Sun, W.R.; Guo, S.R.; Hu, Z.Q.; Park, N.K.; Yoo, Y.S.; Choe, S.J.

    1998-01-01

    The effects of phosphorus on the phase transformation and stress rupture properties of alloy 718 were investigated. The nucleation of δ-phase, which does not contain phosphorus, was suppressed by the enrichment of phosphorus at grain boundaries. A low level of phosphorus resulted in the formation of faults-containing film-like δ-phase along the grain boundaries, while a higher level of phosphorus favored the long lath-like δ-phase precipitation. Phosphorus greatly prolonged the stress rupture life of the alloy in the range of 0.0008-0.013 wt.%, while it reduced the stress rupture life in the range of 0.013-0.049 wt.%. The effect of phosphorus on the stress rupture properties was closely related to its interaction with oxygen. Phosphorus atoms, in the range of 0.0008-0.013 wt.%, enhanced the resistance to oxygen intrusion along the grain boundaries, protected the grain boundaries from decohesion by oxygen atoms and oxidation, and subsequently prolonged the rupture life of the alloy. The protection effect of P is clearly demonstrated by the phenomenon that the crack initiation site was shifted from the surface to the center in the stress-ruptured samples with increasing addition of P. Over 0.013 wt.%, the protection effect of phosphorus is excessive and phosphorus began to display its inherent effect of damaging the grain boundary strength: the stress rupture life of the alloy was reduced accordingly. Maximum stress rupture life was thus obtained at ∼0.013 wt.% P. (orig.)

  1. Creep rupture of structures subjected to variable loading and temperature

    International Nuclear Information System (INIS)

    Wojewodzki, W.

    1975-01-01

    The aim of the present paper is to show on the basis of equations and the analysis of creep mechanisms the possibilities of a description of the creep behavior of material under variable temperature and loading conditions. Also the influence of cyclic proportional loading and temperature gradient upon the rupture life and strains of a thick cylinder is investigated in detail. The obtained theoretical creep curves coincide with the experimental results for investigated steel in the temperature range from 500 0 C to 575 0 C. The constitutive equations together with the functions determined previously are applied to solve the problem of thick cylinder subjected to cyclic proportional pressure and temperature gradient. Numerical results for the thick steel cylinder are presented both in diagrammatical and tabular form. The obtained new results clearly show the significant influence of temperature gradient, cyclic temperature gradient, and cyclic pressure upon the stress redistribution, the magnitude of deformation, the propagation of the front damage and the rupture life. It was found that small temperature fluctuations at elevated temperature can shorten the rupture life very considerably. The introduced description of the creep rupture behavior of material under variable temperature and loading conditions together with the results for the thick cylinder indicate the possibilities of solutions of practical problems encountered in structural mechanics of reactor technology

  2. Cross-cultural adaptation and validation of Persian Achilles tendon Total Rupture Score.

    Science.gov (United States)

    Ansari, Noureddin Nakhostin; Naghdi, Soofia; Hasanvand, Sahar; Fakhari, Zahra; Kordi, Ramin; Nilsson-Helander, Katarina

    2016-04-01

    To cross-culturally adapt the Achilles tendon Total Rupture Score (ATRS) to Persian language and to preliminary evaluate the reliability and validity of a Persian ATRS. A cross-sectional and prospective cohort study was conducted to translate and cross-culturally adapt the ATRS to Persian language (ATRS-Persian) following steps described in guidelines. Thirty patients with total Achilles tendon rupture and 30 healthy subjects participated in this study. Psychometric properties of floor/ceiling effects (responsiveness), internal consistency reliability, test-retest reliability, standard error of measurement (SEM), smallest detectable change (SDC), construct validity, and discriminant validity were tested. Factor analysis was performed to determine the ATRS-Persian structure. There were no floor or ceiling effects that indicate the content and responsiveness of ATRS-Persian. Internal consistency was high (Cronbach's α 0.95). Item-total correlations exceeded acceptable standard of 0.3 for the all items (0.58-0.95). The test-retest reliability was excellent [(ICC)agreement 0.98]. SEM and SDC were 3.57 and 9.9, respectively. Construct validity was supported by a significant correlation between the ATRS-Persian total score and the Persian Foot and Ankle Outcome Score (PFAOS) total score and PFAOS subscales (r = 0.55-0.83). The ATRS-Persian significantly discriminated between patients and healthy subjects. Explanatory factor analysis revealed 1 component. The ATRS was cross-culturally adapted to Persian and demonstrated to be a reliable and valid instrument to measure functional outcomes in Persian patients with Achilles tendon rupture. II.

  3. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  4. A Reliability-Based Determination of Economic Life of Marine power plants

    International Nuclear Information System (INIS)

    Atua, K.

    1999-01-01

    The reliability-based life approach is utilized. Selective failure modes of marine power plants are used for illustration. A case study of the Egyptian Commercial Fleet owned by the Public Sector Company was analyzed and used to establish a demonstration of the expected economic life based on local operating and maintenance conditions. The data acquired is analyzed and failure trend is derived for each failure mode. Probabilistic techniques are used to randomly generate numbers and times of occurrence of different failure modes. The reliability analysis is performed on the life span expected by the manufacture to predict the total number of failures, dependent failures, and cost of failures. Total expenditure due to random failure and cost of scheduled maintenance together with the annual income are utilized (using the time value of money) to determine the economic life of the plant. Conclusions are derived and recommendations for the enhancement of this work in the future are made

  5. Reliability and extended-life potential of EBR-II

    International Nuclear Information System (INIS)

    King, R.W.

    1985-01-01

    Although the longlife potential of liquid-metal-cooled reactors (LMRs) has been only partially demonstrated, many factors point to the potential for exceptionally long life. EBR-II has the opportunity to become the first LMR to achieve an operational lifetime of 30 years or more. In 1984 a study of the extended-life potential of EBR-II identified the factors that contribute to the continued successful operation of EBR-II as a power reactor and experimental facility. Also identified were factors that could cause disruptions in the useful life of the facility. Although no factors were found that would inherently limit the life of EBR-II, measures were identified that could help ensure continued plant availability. These measures include the implementation of more effective surveillance, diagnostic, and control systems to complement the inherent safety and reliability features of EBR-II. An operating lifetime of well beyond 30 years is certainly feasible

  6. A Case of Ruptured Splenic Artery Aneurysm in Pregnancy

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Corey

    2014-01-01

    Full Text Available Background. Rupture of a splenic artery aneurysm is rare complication of pregnancy that is associated with a significant maternal and fetal mortality. Case. A multiparous female presented in the third trimester with hypotension, tachycardia, and altered mental status. A ruptured splenic artery aneurysm was discovered at the time of laparotomy and cesarean delivery. The patient made a full recovery following resection of the aneurysm. The neonate survived but suffered severe neurologic impairment. Conclusion. The diagnosis of ruptured splenic artery aneurysm should be considered in a pregnant woman presenting with signs of intra-abdominal hemorrhage. Early intervention by a multidisciplinary surgical team is key to preserving the life of the mother and fetus.

  7. Globe Rupture

    Directory of Open Access Journals (Sweden)

    Reid Honda

    2017-07-01

    Full Text Available History of present illness: A 46-year-old male presented to the emergency department (ED with severe left eye pain and decreased vision after tripping and striking the left side of his head on the corner of his wooden nightstand. The patient arrived as an inter-facility transfer for a suspected globe rupture with a protective eye covering in place; thus, further physical examination of the eye was not performed by the emergency physician in order to avoid further leakage of aqueous humor. Significant findings: The patient’s computed tomography (CT head demonstrated a deformed left globe, concerning for ruptured globe. The patient had hyperdense material in the posterior segment (see green arrow, consistent with vitreous hemorrhage. CT findings that are consistent with globe rupture may include a collapsed globe, intraocular air, or foreign bodies. Discussion: A globe rupture is a full-thickness defect in the cornea, sclera, or both.1 It is an ophthalmologic emergency. Globe ruptures are almost always secondary to direct perforation via a penetrating mechanism; however, it can occur due to blunt injury if the force generated creates sufficient intraocular pressure to tear the sclera.2 Globes most commonly rupture at the insertions of the intraocular muscles or at the limbus. They are associated with a high rate of concomitant orbital floor fractures.2,3 Possible physical examination findings include a shallow anterior chamber on slit-lamp exam, hyphema, and an irregular “teardrop” pupil. Additionally, a positive Seidel sign, which is performed by instilling fluorescein in the eye and then examining for a dark stream of aqueous humor, is indicative of a globe rupture.4 CT is often used to assess for globe rupture; finds of a foreign body, intraocular air, abnormal contour or volume of the globe, or disruption of the sclera suggest globe rupture.2 The sensitivity of CT scan for diagnosis of globe rupture is only 75%; thus, high clinical

  8. Spontaneous subserosal venous rupture overlying a uterine leiomyoma in a young woman.

    Science.gov (United States)

    Jenayah, Amel Achour; Saoudi, Sarah; Sferi, Nour; Skander, Rim; Marzouk, Sofiène Ben; Cherni, Abdallah; Sfar, Ezzeddine; Chelli, Dalenda; Boudaya, Fethia

    2017-01-01

    Uterine leiomyomas are very common tumors found in women. Rupture of veins on the surface of uterine leiomyoma is an unusual source of hemoperitoneum. It is an extremely uncommon gynaecological cause of hemoperitoneum. It is a life threatening emergency. We report a case of massive intraperitoneal hemorrhage due to rupture of vessels on the surface of subserous leiomyoma. A differential diagnosis of rupture of leiomyoma'ssurface vessel should be considered, while dealing with a case of hemoperitoneum with pelvic mass.

  9. Application of structural reliability and risk assessment to life prediction and life extension decision making

    International Nuclear Information System (INIS)

    Meyer, T.A.; Balkey, K.R.; Bishop, B.A.

    1987-01-01

    There can be numerous uncertainties involved in performing component life assessments. In addition, sufficient data may be unavailable to make a useful life prediction. Structural Reliability and Risk Assessment (SRRA) is primarily an analytical methodology or tool that quantifies the impact of uncertainties on the structural life of plant components and can address the lack of data in component life prediction. As a prelude to discussing the technical aspects of SRRA, a brief review of general component life prediction methods is first made so as to better develop an understanding of the role of SRRA in such evaluations. SRRA is then presented as it is applied in component life evaluations with example applications being discussed for both nuclear and non-nuclear components

  10. Time-variant flexural reliability of RC beams with externally bonded CFRP under combined fatigue-corrosion actions

    International Nuclear Information System (INIS)

    Bigaud, David; Ali, Osama

    2014-01-01

    Time-variant reliability analysis of RC highway bridges strengthened with carbon fibre reinforced polymer CFRP laminates under four possible competing damage modes (concrete crushing, steel rupture after yielding, CFRP rupture and FRP plate debonding) and three degradation factors is analyzed in terms of reliability index β using FORM. The first degradation factor is chloride-attack corrosion which induces reduction in steel area and concrete cover cracking at characteristic key times (corrosion initiation, severe surface cover cracking). The second degradation factor considered is fatigue which leads to damage in concrete and steel rebar. Interaction between corrosion and fatigue crack growth in steel reinforcing bars is implemented. The third degradation phenomenon is the CFRP properties deterioration due to aging. Considering these three degradation factors, the time-dependent flexural reliability profile of a typical simple 15 m-span intermediate girder of a RC highway bridge is constructed under various traffic volumes and under different corrosion environments. The bridge design options follow AASHTO-LRFD specifications. Results of the study have shown that the reliability is very sensitive to factors governing the corrosion. Concrete damage due to fatigue slightly affects reliability profile of non-strengthened section, while service life after strengthening is strongly related to fatigue damage in concrete. - Highlights: • We propose a method to follow the time-variant reliability of strengthened RC beams. • We consider multiple competing failure modes of CFRP strengthened RC beams. • We consider combined degradation mechanisms (corrosion, fatigue, ageing of CFRP)

  11. Multimodality Imaging-based Evaluation of Single-Lumen Silicone Breast Implants for Rupture.

    Science.gov (United States)

    Seiler, Stephen J; Sharma, Pooja B; Hayes, Jody C; Ganti, Ramapriya; Mootz, Ann R; Eads, Emily D; Teotia, Sumeet S; Evans, W Phil

    2017-01-01

    Breast implants are frequently encountered on breast imaging studies, and it is essential for any radiologist interpreting these studies to be able to correctly assess implant integrity. Ruptures of silicone gel-filled implants often occur without becoming clinically obvious and are incidentally detected at imaging. Early diagnosis of implant rupture is important because surgical removal of extracapsular silicone in the breast parenchyma and lymphatics is difficult. Conversely, misdiagnosis of rupture may prompt a patient to undergo unnecessary additional surgery to remove the implant. Mammography is the most common breast imaging examination performed and can readily depict extracapsular free silicone, although it is insensitive for detection of intracapsular implant rupture. Ultrasonography (US) can be used to assess the internal structure of the implant and may provide an economical method for initial implant assessment. Common US signs of intracapsular rupture include the "keyhole" or "noose" sign, subcapsular line sign, and "stepladder" sign; extracapsular silicone has a distinctive "snowstorm" or echogenic noise appearance. Magnetic resonance (MR) imaging is the most accurate and reliable means for assessment of implant rupture and is highly sensitive for detection of both intracapsular and extracapsular rupture. MR imaging findings of intracapsular rupture include the keyhole or noose sign, subcapsular line sign, and "linguine" sign, and silicone-selective MR imaging sequences are highly sensitive to small amounts of extracapsular silicone. © RSNA, 2017.

  12. Influence of composition on precipitation behavior and stress rupture properties in INCONEL RTM740 series superalloys

    Science.gov (United States)

    Casias, Andrea M.

    Increasing demands for energy efficiency and reduction in CO2 emissions have led to the development of advanced ultra-supercritical (AUSC) boilers. These boilers operate at temperatures of 760 °C and pressures of 35 MPa, providing efficiencies close to 50 pct. However, austenitic stainless steels typically used in boiler applications do not have sufficient creep or oxidation resistance. For this reason, nickel (Ni)-based superalloys, such as IN740, have been identified as potential materials for AUSC boiler tube components. However, IN740 is susceptible to heat-affected-zone liquation cracking in the base metal of heavy section weldments. To improve weldability, IN740H was developed. However, IN740H has lower stress rupture ductility compared to IN740. For this reason, two IN740H modifications have been produced by lowering carbon content and increasing boron content. In this study, IN740, IN740H, and the two modified IN740H alloys (modified 1 and 2) were produced with equiaxed grain sizes of 90 ìm (alloys IN740, IN740H, and IN740H modified 1 alloys) and 112 µm (IN740H modified 2 alloy). An aging study was performed at 800 °C on all alloys for 1, 3, 10, and 30 hours to assess precipitation behavior. Stress rupture tests were performed at 760 °C with the goal of attaining stress levels that would yield rupture at 1000 hours. The percent reduction in area was measured after failure as a measure of creep ductility. Light optical, scanning electron, and transmission electron microscopy were used in conjunction with X-ray diffraction to examine precipitation behavior of annealed, aged, and stress rupture tested samples. The amount and type of precipitation that occurred during aging prior to stress rupture testing or in-situ during stress rupture testing influenced damage development, stress rupture life, and ductility. In terms of stress rupture life, IN740H modified 2 performed the best followed by IN740H modified 1 and IN740, which performed similarly, and IN740

  13. Pseudodynamic Source Characterization for Strike-Slip Faulting Including Stress Heterogeneity and Super-Shear Ruptures

    KAUST Repository

    Mena, B.

    2012-08-08

    Reliable ground‐motion prediction for future earthquakes depends on the ability to simulate realistic earthquake source models. Though dynamic rupture calculations have recently become more popular, they are still computationally demanding. An alternative is to invoke the framework of pseudodynamic (PD) source characterizations that use simple relationships between kinematic and dynamic source parameters to build physically self‐consistent kinematic models. Based on the PD approach of Guatteri et al. (2004), we propose new relationships for PD models for moderate‐to‐large strike‐slip earthquakes that include local supershear rupture speed due to stress heterogeneities. We conduct dynamic rupture simulations using stochastic initial stress distributions to generate a suite of source models in the magnitude Mw 6–8. This set of models shows that local supershear rupture speed prevails for all earthquake sizes, and that the local rise‐time distribution is not controlled by the overall fault geometry, but rather by local stress changes on the faults. Based on these findings, we derive a new set of relations for the proposed PD source characterization that accounts for earthquake size, buried and surface ruptures, and includes local rise‐time variations and supershear rupture speed. By applying the proposed PD source characterization to several well‐recorded past earthquakes, we verify that significant improvements in fitting synthetic ground motion to observed ones is achieved when comparing our new approach with the model of Guatteri et al. (2004). The proposed PD methodology can be implemented into ground‐motion simulation tools for more physically reliable prediction of shaking in future earthquakes.

  14. Creep rupture properties under varying load/temperature conditions on a nickel-base heat-resistant alloy strengthened by boron addition

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Tanabe, Tatsuhiko; Nakajima, Hajime

    1994-01-01

    A series of constant load and temperature creep rupture tests and varying load and temperature creep rupture tests was carried out on Hastelloy XR whose boron content level is 60 mass ppm at 900 and 1000 C in order to examine the behavior of the alloy under varying load and temperature conditions. The life fraction rule completely fails in the prediction of the creep rupture life under varying load and temperature conditions though the rule shows good applicability for Hastelloy XR whose boron content level is below 10 mass ppm. The modified life fraction rule has been proposed based on the dependence of the creep rupture strength on the boron content level of the alloy. The modified rule successfully predicts the creep rupture life under the test conditions from 1000 to 900 C. The trend observed in the tests from 900 to 1000 C can be qualitatively explained by the mechanism that the oxide film which is formed during the prior exposure to 900 C plays the role of the protective barrier against the boron dissipation into the environment. (orig.)

  15. Consideration on evaluation of internal pressure creep rupture for tube with circumferential joint

    International Nuclear Information System (INIS)

    Nagato, Kotaro; Satoh, Keisuke

    1983-01-01

    The behavior of internal pressure creep rupture of the thin-walled cylinders with circumferential joints is affected by the combination of creep characteristics of parent materials and weld metals. In particular, the compatibility of the creep strain rate of parent materials and weld metals becomes an important controlling factor. The behavior of internal pressure creep of the welded parts in circumferential joint cylinders can be evaluated simply with the uniaxial creep data of parent materials and weld metals, considering it by approximately substituting with the creep behavior of a uniaxial longitudinal joint. The method of evaluation is, first, to analyze the breaking behavior of uniaxial longitudinal joints using the uniaxial creep characteristic values of parent materials and weld metals, and next, by combining the equation for the relation between the rupture times of uniaxial creep and internal pressure creep with the analyzed breaking behavior of uniaxial joints, the internal pressure creep rupture behavior of the cylinders with circumferential joints can be evaluated. The internal pressure creep behavior of the thin-walled cylinders with circumferential joints, their rupture life and the uniaxial creep rupture life of longitudinal joints, and the examination of Hastelloy X cylinders are reported. (Kako, I.)

  16. Analysis and computer program for rupture-risk prediction of abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Li Zhonghua

    2006-03-01

    Full Text Available Abstract Background Ruptured abdominal aortic aneurysms (AAAs are the 13th leading cause of death in the United States. While AAA rupture may occur without significant warning, its risk assessment is generally based on critical values of the maximum AAA diameter (>5 cm and AAA-growth rate (>0.5 cm/year. These criteria may be insufficient for reliable AAA-rupture risk assessment especially when predicting possible rupture of smaller AAAs. Methods Based on clinical evidence, eight biomechanical factors with associated weighting coefficients were determined and summed up in terms of a dimensionless, time-dependent severity parameter, SP(t. The most important factor is the maximum wall stress for which a semi-empirical correlation has been developed. Results The patient-specific SP(t indicates the risk level of AAA rupture and provides a threshold value when surgical intervention becomes necessary. The severity parameter was validated with four clinical cases and its application is demonstrated for two AAA cases. Conclusion As part of computational AAA-risk assessment and medical management, a patient-specific severity parameter 0

  17. Rupture of hepatocellular carcinoma following transcatheter arterial chemoembolization: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyo Jin; Lee, Byung Hoon; Hwang, Yoon Joon; Kim, Su Young; Lee, Ji Young [Ilsan Paik Hospital/Inje Univ. School of Medicine, Goyang (Korea, Republic of); Han, Yoon Hee [Seonam Hospital/Ewha Womans Univ. School of Medicine, Seoul (Korea, Republic of)

    2012-08-15

    Transcatheter arterial chemoembolization (TACE) is known to be an effective palliative treatment for unresectable hepatocellular carcinoma (HCC). Serious complications, such as neutropenic sepsis and hepatic decompensation, are well known. A HCC rupture following TACE is a rare complication; however, it can be life threatening if it occurs. In a 75 year old male patient who subsequently developed capsular rupture of the lipiodol laden mass and several free intraperitoneal chemoembolization agents with hemoperitoneum, we report a case of a ruptured HCC that superficially located arterial enhancing and early wash out mass in the right hepatic dome following TACE.

  18. Total rupture of hydatid cyst of liver in to common bile duct: a case report.

    Science.gov (United States)

    Robleh, Hassan; Yassine, Fahmi; Driss, Khaiz; Khalid, Elhattabi; Fatima-Zahra, Bensardi; Saad, Berrada; Rachid, Lefriyekh; Abdalaziz, Fadil; Najib, Zerouali Ouariti

    2014-01-01

    Rupture of hydatid liver cyst into biliary tree is frequent complications that involve the common hepatic duct, lobar biliary branches, the small intrahepatic bile ducts,but rarely rupture into common bile duct. The rupture of hydatid cyst is serious life threating event. The authors are reporting a case of total rupture of hydatid cyst of liver into common bile duct. A 50-year-old male patient who presented with acute cholangitis was diagnosed as a case of totally rupture of hydatid cyst on Abdominal CT Scan. Rupture of hydatid cyst of liver into common bile duct and the gallbladder was confirmed on surgery. Treated by cholecystectomy and T-tube drainage of Common bile duct.

  19. Mycotic Aneurysm of the Celiac Trunk: From Early CT Sign to Rupture

    International Nuclear Information System (INIS)

    Serafino, Gianpiero; Vroegindeweij, Dammis; Boks, Simone; Harst, Erwin van der

    2005-01-01

    We present a case of the rapid development and rupture of a mycotic celiac trunk aneurysm. Initiallyon multislice computed tomography (ms-CT) there was a normal celiac trunk with minimal haziness of the surrounding fat. Only 2 weeks later the patient went into hypovolemic shock due to a ruptured celiac aneurysm. Although aneurysms of the visceral arteries are rare, they are of major clinical importance as they carry a life-threatening risk of rupture. This case illustrates the use of ms-CT in detecting and evaluating visceral aneurysms, in order to prevent emergency operation

  20. Improvement of stress-rupture property by Cr addition in Ni-based single crystal superalloys

    International Nuclear Information System (INIS)

    Chen, J.Y.; Feng, Q.; Cao, L.M.; Sun, Z.Q.

    2011-01-01

    Research highlights: → Cr improved the stress-rupture life of single crystal superalloys significantly. → Cr increased the Re partitioning ratio and resulted in more negative misfit. → Mechanism for improving the stress-rupture life by Cr addition is addressed here. - Abstract: The effects of Cr addition on the microstructure and stress-rupture property have been investigated in three experimental Ni-based single crystal superalloys containing various levels of Cr addition (0-5.7 wt.%). The Re partitioning ratio increased and the lattice misfit became more negative with increasing the Cr addition in both dendrite core and interdendritic region. The changes of elemental partitioning behaviors and the lattice misfit show good agreement with the change of γ' morphology. Cr addition increased the stress-rupture life at 1100 deg. C/140 MPa significantly due to higher γ' volume fraction, more negative lattice misfit and a well rafting structure as well as less width of γ channels. High Cr addition (5.7 wt.%) increased the degree of Re and Cr supersaturation in the γ phase and promoted the formation of topologically close-packed (TCP) phases significantly under thermal exposure and creep deformation at 1100 deg. C.

  1. Reliability Centered Maintenance as a tool for plant life extension

    International Nuclear Information System (INIS)

    Elliott, J.O.; Mulay, J.N.; Nakahara, Y.

    1991-01-01

    Currently in the nuclear industry there is a growing interest in lowering the cost and complexity of maintenance activities while at the same time improving plant reliability and safety in an effort to prepare for the technical and regulatory challenges of life extension. This seemingly difficult task is being aided by the introduction of a maintenance philosophy developed originally by the airline industry and subsequently applied with great success both in that industry and the U.S. military services. Reliability Centered Maintenance (RCM), in its basic form, may be described as a consideration of reliability and maintenance problems from a systems level approach, allowing a focus on preservation of system function as the aim of a maintenance program optimized for both safety and economics. It is this systematic view of plant maintenance, with the emphasis on overall functions rather than individual parts and components which sets RCM apart from past nuclear plant maintenance philosophies. It is also the factor which makes application of RCM an ideal first step in development of strategies for life extension, both for aging plants, and for plants just beginning their first license term. (J.P.N.)

  2. Rupture disc

    International Nuclear Information System (INIS)

    Newton, R.G.

    1977-01-01

    The intermediate heat transport system for a sodium-cooled fast breeder reactor includes a device for rapidly draining the sodium therefrom should a sodium-water reaction occur within the system. This device includes a rupturable member in a drain line in the system and means for cutting a large opening therein and for positively removing the sheared-out portion from the opening cut in the rupturable member. According to the preferred embodiment of the invention the rupturable member includes a solid head seated in the end of the drain line having a rim extending peripherally therearound, the rim being clamped against the end of the drain line by a clamp ring having an interior shearing edge, the bottom of the rupturable member being convex and extending into the drain line. Means are provided to draw the rupturable member away from the drain line against the shearing edge to clear the drain line for outflow of sodium therethrough

  3. Creep rupture properties under varying load/temperature conditions on a nickel-base heat-resistant alloy strengthened by boron addition

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime; Tanabe, Tatsuhiko.

    1993-09-01

    A series of constant load and temperature creep rupture tests and varying load and temperature creep rupture tests was carried out on Hastelloy XR whose boron content level is 60 mass ppm at 900 and 1000degC in order to examine the behavior of the alloy under varying load and temperature conditions. The life fraction rule completely fails in the prediction of the creep rupture life under varying load and temperature conditions though the rule shows good applicability for Hastelloy XR whose boron content level is below 10 mass ppm. The modified life fraction rule has been proposed based on the dependence of the creep rupture strength on the born content level of the alloy. The modified rule successfully predicts the creep rupture life under the test conditions from 1000degC to 900degC. The trend observed in the tests from 900degC to 1000degC can be qualitatively explained by the mechanism that the oxide film which is formed during the prior exposure to 900degC plays the role of the protective barrier against the boron dissipation into the environment. (author)

  4. Intraoperative Physical Examination for Diagnosis of Interosseous Ligament Rupture-Cadaveric Study.

    Science.gov (United States)

    Kachooei, Amir Reza; Rivlin, Michael; Wu, Fei; Faghfouri, Aram; Eberlin, Kyle R; Ring, David

    2015-09-01

    To study the intraobserver and interobserver reliability of the diagnosis of interosseous ligament (IOL) rupture in a cadaver model. On 12 fresh frozen cadavers, radial heads were cut using an identical incision and osteotomy. After randomization, the soft tissues of the limbs were divided into 4 groups: both IOL and triangular fibrocartilage (TFCC) intact; IOL disruption but TFCC intact; both IOL and TFCC divided; and IOL intact but TFCC divided. All incisions had identical suturing. After standard instruction and demonstration of radius pull-push and radius lateral pull tests, 10 physician evaluators with different levels of experience examined the cadaver limbs in a standardized way (elbow at 90° with the forearm held in both supination and pronation) and were asked to classify them into one of the 4 groups. Next, the same examiners were asked to re-examine the limbs after randomly changing the order of examination. The interobserver reliability of agreement for the diagnosis of IOL injury (groups 2 and 3) was fair in both rounds of examination and the intraobserver reliability was moderate. The intra- and interobserver reliabilities of agreement for the 4 groups of injuries among the examiners were fair in both rounds of examination. The sensitivity, specificity, accuracy, positive, and negative predictive values were all around 70%. The likelihood of a positive test corresponding with the presence of IOL rupture (positive likelihood ratio) was 2.2. The likelihood of a negative test correctly diagnosing an intact IOL was 0.40. In cadavers, intraoperative tests had fair reliability and 70% accuracy for the diagnosis of IOL rupture using the push-pull and lateral pull maneuvers. The level of experience did not have any effect on the correct diagnosis of intact versus disrupted IOL. Although not common, some failure of surgeries for traumatic elbow fracture-dislocations is because of failure in timely diagnosis of IOL disruption. Copyright © 2015 American

  5. Microstructure-based assessment of creep rupture behaviour of cast-forged P91 steel

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Chandan, E-mail: chandanpy.1989@gmail.com [Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Uttrakhand 247667 (India); Mahapatra, M.M. [School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Odisha 751013 (India); Kumar, Pradeep; Vidyrathy, R.S. [Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Uttrakhand 247667 (India); Srivastava, A. [Senior Engineer, HEEP Section, BHEL Haridwar (India)

    2017-05-17

    The work presented in this study was performed with the intent to characterize the microstructure evolution for short term creep exposure of cast-forged P91 steel. The short-term creep test was performed at temperature range of 620–650 °C and stresses ranging from 120 to 200 MPa. To characterize the sample after creep exposure, field emission scanning electron microscopy (FESEM) with energy dispersive X-ray spectroscopy (EDS), optical microscope and micro-hardness testing were utilized. Creep tests were performed on round creep specimens. For low temperature service condition, longer creep life was obtained. The fracture surface of creep ruptured specimen were characterized by using the FESEM. The transgranular fracture mode was noticed in all the tests condition. The creep rupture life was found to be decreased with increase in applied stress. The maximum rupture life was measured about to be 3329.28 h for the sample exposed at 620 °C for 120 MPa. A negligible microstructural change was measured in gripping area compared to the gauge area (necking area) of crept sample. The laves phase formation was also noticed along the grain boundaries for creep exposure life of 3329.28 h.

  6. Microstructure-based assessment of creep rupture behaviour of cast-forged P91 steel

    International Nuclear Information System (INIS)

    Pandey, Chandan; Mahapatra, M.M.; Kumar, Pradeep; Vidyrathy, R.S.; Srivastava, A.

    2017-01-01

    The work presented in this study was performed with the intent to characterize the microstructure evolution for short term creep exposure of cast-forged P91 steel. The short-term creep test was performed at temperature range of 620–650 °C and stresses ranging from 120 to 200 MPa. To characterize the sample after creep exposure, field emission scanning electron microscopy (FESEM) with energy dispersive X-ray spectroscopy (EDS), optical microscope and micro-hardness testing were utilized. Creep tests were performed on round creep specimens. For low temperature service condition, longer creep life was obtained. The fracture surface of creep ruptured specimen were characterized by using the FESEM. The transgranular fracture mode was noticed in all the tests condition. The creep rupture life was found to be decreased with increase in applied stress. The maximum rupture life was measured about to be 3329.28 h for the sample exposed at 620 °C for 120 MPa. A negligible microstructural change was measured in gripping area compared to the gauge area (necking area) of crept sample. The laves phase formation was also noticed along the grain boundaries for creep exposure life of 3329.28 h.

  7. The Effect of Epoxy Molding Compound Floor Life to Reliability Performance and mold ability for QFN Package

    Science.gov (United States)

    Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak

    2017-09-01

    This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing

  8. Fetal membrane healing after spontaneous and iatrogenic membrane rupture: A review of current evidence

    OpenAIRE

    Devlieger, R.; Millar, L. K.; Bryant-Greenwood, G.; Lewi, L.; Deprest, J. A.

    2006-01-01

    In view of the important protective role of the fetal membranes, wound sealing, tissue regeneration, or wound healing could be life saving in cases of preterm premature rupture of the membranes. Although many investigators are studying the causes of preterm premature rupture of membranes, the emphasis has not been on the wound healing capacity of the fetal membranes. In this review, the relevant literature on the pathophysiologic condition that leads to preterm premature rupture of membranes ...

  9. Renal allograft rupture: US diagnosis

    International Nuclear Information System (INIS)

    Maklad, N.F.

    1987-01-01

    The US appearances in seven pathologically and/or surgically proved cases of renal allograft rupture are presented. These include a triangular or amorphous echogenic area in the cortex and medulla in a polar location, an echogenic band or wavy, branching anechoic lines in the hyperechoic region, a subcapsular hematoma, and an extrarenal hematoma in direct continuity with the echogenic area. Duplex Doppler examination in renal allograft rupture shows marked reduction of absence of the diastolic component of the velocity waveform in the arcuate and interlobar arteries, with reduction in amplitude of the systolic wave form. Correlation of the US appearances with gross and microscopic pathologic findings indicates that the echogenic area is due to an intrarenal hematoma, while the echogenic band represents the cortical laceration with adherent blood clots. The US-duplex Doppler examination should be the primary diagnostic modality in this life-threatening condition

  10. Inaccuracy of reference curves used in the structures design by creep rupture indices

    International Nuclear Information System (INIS)

    Couto, P.R.G.; Silveira, T.L. da; Monteiro, S.N.; Rio de Janeiro Univ.

    1980-01-01

    The majority of Project Codes considers explicity rupture as one of the critereas for the extinction of the life of structures which operate at high temperatures. The modifications of the materials deformation and fracture mechanisms, are discussed. Their effects on the creep rupture indices used on projects are also considered in terms of parametric methods. (Author) [pt

  11. Use of hospital discharge data to monitor uterine rupture--Massachusetts, 1990-1997.

    Science.gov (United States)

    2000-03-31

    Uterine rupture (UR), a potentially life-threatening condition for both mother and infant, occurs in vaginal birth after cesarean section (VBAC) (1-4). During 1990-1997, the proportion of vaginal deliveries among women who had previous cesarean sections (CS) in Massachusetts increased 50%, from 22.3% to 33.5% (5). Concern about a corresponding increase in UR prompted the Massachusetts Department of Public Health and CDC to initiate a state-wide investigation that included an assessment of the validity and reliability of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) (6), codes in hospital discharge data to identify UR cases. This report summarizes the results of the investigation, which indicate that ICD-9-CM codes related to UR, designed before increased concern about UR, lack adequate specificity for UR surveillance and have not been applied consistently over time.

  12. Complementary Ruptures of Surface Ruptures and Deep Asperity during the 2014 Northern Nagano, Japan, Earthquake (MW 6.3)

    Science.gov (United States)

    Asano, K.; Iwata, T.; Kubo, H.

    2015-12-01

    A thrust earthquake of MW 6.3 occurred along the northern part of the Itoigawa-Shizuoka Tectonic Line (ISTL) in the northern Nagano prefecture, central Japan, on November 22, 2014. This event was reported to be related to an active fault, the Kamishiro fault belonging to the ISTL (e.g., HERP, 2014). The surface rupture is observed along the Kamishiro fault (e.g., Lin et al., 2015; Okada et al., 2015). We estimated the kinematic source rupture process of this earthquake through the multiple time-window linear waveform inversion method (Hartzell and Heaton, 1983). We used velocity waveforms in 0.05-1 Hz from 12 strong motion stations of K-NET, KiK-net (NIED), JMA, and Nagano prefecture (SK-net, ERI). In order to enhance the reliability in Green's functions, we assumed one-dimensional velocity structure models different for the different stations, which were extracted from the nation-wide three-dimensional velocity structure model, Japan Integrated Velocity Structure Model (JIVSM, Koketsu et al., 2012). Considering the spatial distribution of aftershocks (Sakai et al., 2015) and surface ruptures, the assumed fault model consisted of two dip-bending fault segments with different dip angles between the northern and southern segments. The total length and width of the fault plane is 20 km and 13 km, relatively, and the fault model is divided into 260 subfaults of 1 km × 1 km in space and six smoothed ramp functions in time. An asperity or large slip area with a peak slip of 1.9 m was estimated in the lower plane of the northern segment in the approximate depth range of 4 to 8 km. The depth extent of this asperity is consistent with the seismogenic zone revealed by past studies (e.g., Panayotopoulos et al., 2014). In contrast, the slip in the southern segment is relatively concentrated in the shallow portion of the segment where the surface ruptures were found along the Kamishiro fault. The overall spatial rupture pattern of the source fault, in which the deep asperity

  13. Integrated Design Software Predicts the Creep Life of Monolithic Ceramic Components

    Science.gov (United States)

    1996-01-01

    Significant improvements in propulsion and power generation for the next century will require revolutionary advances in high-temperature materials and structural design. Advanced ceramics are candidate materials for these elevated-temperature applications. As design protocols emerge for these material systems, designers must be aware of several innate features, including the degrading ability of ceramics to carry sustained load. Usually, time-dependent failure in ceramics occurs because of two different, delayedfailure mechanisms: slow crack growth and creep rupture. Slow crack growth initiates at a preexisting flaw and continues until a critical crack length is reached, causing catastrophic failure. Creep rupture, on the other hand, occurs because of bulk damage in the material: void nucleation and coalescence that eventually leads to macrocracks which then propagate to failure. Successful application of advanced ceramics depends on proper characterization of material behavior and the use of an appropriate design methodology. The life of a ceramic component can be predicted with the NASA Lewis Research Center's Ceramics Analysis and Reliability Evaluation of Structures (CARES) integrated design programs. CARES/CREEP determines the expected life of a component under creep conditions, and CARES/LIFE predicts the component life due to fast fracture and subcritical crack growth. The previously developed CARES/LIFE program has been used in numerous industrial and Government applications.

  14. Importance of CT Imaging on Spontaneous Rupture of Renal Angiomyolipoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Fatma Gundogdu

    2016-02-01

    Full Text Available Renal angiomyolipomas have a high risk of rupture when they are large and associated with aneurysms. The most serious complication that may occur is life-threatening intratumoral bleeding. Immediate interventional therapies to stop bleeding are required. Herein, we report on a 16-year-old female patient with a retroperitoneal hematoma due to a spontaneous renal angiomyolipoma rupture by computed tomography.

  15. Ruptured eardrum

    Science.gov (United States)

    ... eardrum ruptures. After the rupture, you may have: Drainage from the ear (drainage may be clear, pus, or bloody) Ear noise/ ... doctor to see the eardrum. Audiology testing can measure how much hearing has been lost. Treatment You ...

  16. Dynamic response of INTOR/NET blankets after coolant tube rupture

    International Nuclear Information System (INIS)

    Klippel, H.T.

    1985-01-01

    The dynamic response of different water-cooled liquid Li 17 Pb 83 breeder blanket modules has been calculated to study the potential of these modules in case of coolant tube rupture. Numerical calculations with the code PISCES have been carried out taking into account the fluid-structure interaction and the elasto-plastic behaviour of the structural material. The results show that for inert coolant characteristics the proposed conceptual designs for NET and INTOR have sufficient resistance against coolant tube rupture but when taking into account energy release due to chemical reaction of water with LiPb-alloy up to doubling of the wall thickness has to be envisaged to guarantee structural reliability. (orig.)

  17. Harmony in Life Scale - Turkish version: Studies of validity and reliability

    Directory of Open Access Journals (Sweden)

    Seydi Ahmet Satici

    2017-11-01

    Full Text Available Abstract This article presents the adaptation and psychometric evaluation of the Turkish version of Harmony in Life Scale (Turkish-HiL. The present paper investigates (study 1; N 1 = 253 confirmatory factor analysis, measurement invariance; (study 2; N 2 = 231 concurrent validity; (study 3; N 3 = 260 convergent and known-group validities; (study 4; N t − t = 50 test-retest, Cronbach alpha, and composite reliabilities of the Turkish-HiL. In study 1, based on a confirmatory factor analysis, results confirmed that unidimensional-factor structure. The results suggested that the model demonstrated a configural and metric invariance across the gender groups. In study 2, Turkish-HiL significantly correlated with measures of satisfaction with life, subjective happiness, positive affect, and negative affect. In study 3, Turkish-HiL was predicted positively by flourishing, conversely, negatively predicted by depression, anxiety, and stress. Finally, in study 4, alpha, composite and test-retest reliabilities are acceptable. Overall, the scale presented here may prove useful for satisfactorily assessing, in Turkish, the harmony in life of the university students.

  18. Saved from a fatal flight: A ruptured splenic artery aneurysm in a pregnant woman

    Directory of Open Access Journals (Sweden)

    Anke C. Heitkamp

    2015-01-01

    Conclusion: In case of pregnant women with acute abdomen and hypovolemia, emergency physicians, surgeons, anesthesiologists, and gynecologists should be aware of the possibility of a ruptured SAA, apart from more common causes like placental abruption, placenta percreta, or uterine rupture. Early recognition and prompt multidisciplinary treatment might save the life of mother and child.

  19. Ruptured heterotopic pregnancy and subsequent vaginal delivery at ...

    African Journals Online (AJOL)

    Background: Heterotopic pregnancy is the co- existence of intrauterine and extrauterine gestation at the same time. The condition is life threatening when the ectopic pregnancy ruptures and it is unrecognized. Objective: To report the first successfully managed case of heterotopic pregnancy in a woman without obvious risk ...

  20. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  1. Pipeline integrity model-a formative approach towards reliability and life assessment

    International Nuclear Information System (INIS)

    Sayed, A.M.; Jaffery, M.A.

    2005-01-01

    Pipe forms an integral part of transmission medium in oil and gas industry. This holds true for both upstream and downstream segments of this global energy business. With the aging of this asset base, emphasis on its operational aspects has been under immense considerations from the operators and regulators sides. Moreover, the milieu of information area and enhancement in global trade has lifted the barriers on means to forge forward towards better utilization of resources. This has resulted in optimized solutions as priority for business and technical manager's world over. There is a paradigm shift from mere development of 'smart materials' to 'low life cycle cost material'. The force inducing this change is a rationale one: the recovery of development costs is no more a problem in a global community; rather it is the pay-off time which matters most to the materials end users. This means that decision makers are not evaluating just the price offered but are keen to judge the entire life cycle cost of a product. The integrity of pipe are affected by factors such as corrosion, fatigue-crack growth, stress-corrosion cracking, and mechanical damage. Extensive research in the area of reliability and life assessment has been carried out. A number of models concerning with the reliability issues of pipes have been developed and are being used by a number of pipeline operators worldwide. Yet, it is emphasised that there are no substitute for sound engineering judgment and allowance for factors of safety. The ability of a laid down pipe network to transport the intended fluid under pre-defined conditions for the entire project envisaged life, is referred to the reliability of system. The reliability is built into the product through extensive benchmarking against industry standard codes. The process of pipes construction for oil and gas service is regulated through American Petroleum Institute's Specification for Line Pipe. Subsequently, specific programs have been

  2. Toward tsunami early warning system in Indonesia by using rapid rupture durations estimation

    International Nuclear Information System (INIS)

    Madlazim

    2012-01-01

    Indonesia has Indonesian Tsunami Early Warning System (Ina-TEWS) since 2008. The Ina-TEWS has used automatic processing on hypocenter; Mwp, Mw (mB) and Mj. If earthquake occurred in Ocean, depth 7, then Ina-TEWS announce early warning that the earthquake can generate tsunami. However, the announcement of the Ina-TEWS is still not accuracy. Purposes of this research are to estimate earthquake rupture duration of large Indonesia earthquakes that occurred in Indian Ocean, Java, Timor sea, Banda sea, Arafura sea and Pasific ocean. We analyzed at least 330 vertical seismogram recorded by IRIS-DMC network using a direct procedure for rapid assessment of earthquake tsunami potential using simple measures on P-wave vertical seismograms on the velocity records, and the likelihood that the high-frequency, apparent rupture duration, T dur . T dur can be related to the critical parameters rupture length (L), depth (z), and shear modulus (μ) while T dur may be related to wide (W), slip (D), z or μ. Our analysis shows that the rupture duration has a stronger influence to generate tsunami than Mw and depth. The rupture duration gives more information on tsunami impact, Mo/μ, depth and size than Mw and other currently used discriminants. We show more information which known from the rupture durations. The longer rupture duration, the shallower source of the earthquake. For rupture duration greater than 50 s, the depth less than 50 km, Mw greater than 7, the longer rupture length, because T dur is proportional L and greater Mo/μ. Because Mo/μ is proportional L. So, with rupture duration information can be known information of the four parameters. We also suggest that tsunami potential is not directly related to the faulting type of source and for events that have rupture duration greater than 50 s, the earthquakes generated tsunami. With available real-time seismogram data, rapid calculation, rupture duration discriminant can be completed within 4–5 min after an earthquake

  3. The prediction of reliability and residual life of reactor pressure components

    International Nuclear Information System (INIS)

    Nemec, J.; Antalovsky, S.

    1978-01-01

    The paper deals with the problem of PWR pressure components reliability and residual life evaluation and prediction. A physical model of damage cumulation which serves as a theoretical basis for all considerations presents two major aspects. The first one describes the dependence of the degree of damage in the crack leading-edge in pressure components on the reactor system load-time history, i.e. on the number of transient loads. Both stages, fatigue crack initiation and growth through the wall until the critical length is reached, are investigated. The crack is supposed to initiate at the flaws in a strength weld joint or in the bimetallic weld of the base ferritic steel and the austenitic stainless overlay cladding. The growth rates of developed cracks are analysed in respect to different load-time histories. Important cyclic properties of some steels are derived from the low-cycle fatigue theory. The second aspect is the load-time history-dependent process of precipitation, deformation and radiation aging, characterized entirely by the critical crack-length value mentioned above. The fracture point, defined by the equation ''crack-length=critical value'' and hence the residual life, can be evaluated using this model and verified by in-service inspection. The physical model described is randomized by considering all the parameters of the model as random. Monte Carlo methods are applied and fatigue crack initiation and growth is simulated. This permits evaluation of the reliability and residual life of the component. The distributions of material and load-time history parameters are needed for such simulation. Both the deterministic and computer-simulated probabilistic predictions of reliability and residual life are verified by prior-to-failure sequential testing of data coming from in-service NDT periodical inspections. (author)

  4. Reliability of piping system components. Framework for estimating failure parameters from service data

    International Nuclear Information System (INIS)

    Nyman, R.; Hegedus, D.; Tomic, B.; Lydell, B.

    1997-12-01

    This report summarizes results and insights from the final phase of a R and D project on piping reliability sponsored by the Swedish Nuclear Power Inspectorate (SKI). The technical scope includes the development of an analysis framework for estimating piping reliability parameters from service data. The R and D has produced a large database on the operating experience with piping systems in commercial nuclear power plants worldwide. It covers the period 1970 to the present. The scope of the work emphasized pipe failures (i.e., flaws/cracks, leaks and ruptures) in light water reactors (LWRs). Pipe failures are rare events. A data reduction format was developed to ensure that homogenous data sets are prepared from scarce service data. This data reduction format distinguishes between reliability attributes and reliability influence factors. The quantitative results of the analysis of service data are in the form of conditional probabilities of pipe rupture given failures (flaws/cracks, leaks or ruptures) and frequencies of pipe failures. Finally, the R and D by SKI produced an analysis framework in support of practical applications of service data in PSA. This, multi-purpose framework, termed 'PFCA'-Pipe Failure Cause and Attribute- defines minimum requirements on piping reliability analysis. The application of service data should reflect the requirements of an application. Together with raw data summaries, this analysis framework enables the development of a prior and a posterior pipe rupture probability distribution. The framework supports LOCA frequency estimation, steam line break frequency estimation, as well as the development of strategies for optimized in-service inspection strategies

  5. Reliability of piping system components. Framework for estimating failure parameters from service data

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, R [Swedish Nuclear Power Inspectorate, Stockholm (Sweden); Hegedus, D; Tomic, B [ENCONET Consulting GesmbH, Vienna (Austria); Lydell, B [RSA Technologies, Vista, CA (United States)

    1997-12-01

    This report summarizes results and insights from the final phase of a R and D project on piping reliability sponsored by the Swedish Nuclear Power Inspectorate (SKI). The technical scope includes the development of an analysis framework for estimating piping reliability parameters from service data. The R and D has produced a large database on the operating experience with piping systems in commercial nuclear power plants worldwide. It covers the period 1970 to the present. The scope of the work emphasized pipe failures (i.e., flaws/cracks, leaks and ruptures) in light water reactors (LWRs). Pipe failures are rare events. A data reduction format was developed to ensure that homogenous data sets are prepared from scarce service data. This data reduction format distinguishes between reliability attributes and reliability influence factors. The quantitative results of the analysis of service data are in the form of conditional probabilities of pipe rupture given failures (flaws/cracks, leaks or ruptures) and frequencies of pipe failures. Finally, the R and D by SKI produced an analysis framework in support of practical applications of service data in PSA. This, multi-purpose framework, termed `PFCA`-Pipe Failure Cause and Attribute- defines minimum requirements on piping reliability analysis. The application of service data should reflect the requirements of an application. Together with raw data summaries, this analysis framework enables the development of a prior and a posterior pipe rupture probability distribution. The framework supports LOCA frequency estimation, steam line break frequency estimation, as well as the development of strategies for optimized in-service inspection strategies. 63 refs, 30 tabs, 22 figs.

  6. Slow rupture of frictional interfaces

    Science.gov (United States)

    Bar Sinai, Yohai; Brener, Efim A.; Bouchbinder, Eran

    2012-02-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not completely understood. We show that slow rupture is an intrinsic and robust property of simple non-monotonic rate-and-state friction laws. It is associated with a new velocity scale cmin, determined by the friction law, below which steady state rupture cannot propagate. We further show that rupture can occur in a continuum of states, spanning a wide range of velocities from cmin to elastic wave-speeds, and predict different properties for slow rupture and ordinary fast rupture. Our results are qualitatively consistent with recent high-resolution laboratory experiments and may provide a theoretical framework for understanding slow rupture phenomena along frictional interfaces.

  7. Global catalog of earthquake rupture velocities shows anticorrelation between stress drop and rupture velocity

    Science.gov (United States)

    Chounet, Agnès; Vallée, Martin; Causse, Mathieu; Courboulex, Françoise

    2018-05-01

    Application of the SCARDEC method provides the apparent source time functions together with seismic moment, depth, and focal mechanism, for most of the recent earthquakes with magnitude larger than 5.6-6. Using this large dataset, we have developed a method to systematically invert for the rupture direction and average rupture velocity Vr, when unilateral rupture propagation dominates. The approach is applied to all the shallow (z earthquakes of the catalog over the 1992-2015 time period. After a careful validation process, rupture properties for a catalog of 96 earthquakes are obtained. The subsequent analysis of this catalog provides several insights about the seismic rupture process. We first report that up-dip ruptures are more abundant than down-dip ruptures for shallow subduction interface earthquakes, which can be understood as a consequence of the material contrast between the slab and the overriding crust. Rupture velocities, which are searched without any a-priori up to the maximal P wave velocity (6000-8000 m/s), are found between 1200 m/s and 4500 m/s. This observation indicates that no earthquakes propagate over long distances with rupture velocity approaching the P wave velocity. Among the 23 ruptures faster than 3100 m/s, we observe both documented supershear ruptures (e.g. the 2001 Kunlun earthquake), and undocumented ruptures that very likely include a supershear phase. We also find that the correlation of Vr with the source duration scaled to the seismic moment (Ts) is very weak. This directly implies that both Ts and Vr are anticorrelated with the stress drop Δσ. This result has implications for the assessment of the peak ground acceleration (PGA) variability. As shown by Causse and Song (2015), an anticorrelation between Δσ and Vr significantly reduces the predicted PGA variability, and brings it closer to the observed variability.

  8. Surgical management of spontaneous ruptured hepatocellular adenoma

    Directory of Open Access Journals (Sweden)

    Marcelo Augusto Fontenelle Ribeiro Junior

    2009-01-01

    Full Text Available AIMS: Spontaneous ruptured hepatocellular adenoma (SRHA is a rare life-threatening condition that may require surgical treatment to control hemorrhaging and also stabilize the patient. We report a series of emergency surgeries performed at our institution for this condition. METHODS: We reviewed medical records and radiology files of 28 patients (from 1989 to 2006 with a proven diagnosis of hepatocellular adenoma (HA. Three (10.7% of 28 patients had spontaneous ruptured hepatocellular adenoma, two of which were associated with intrahepatic hemorrhage while one had intraperitoneal bleeding. Two patients were female and one was male. Both female patients had a background history of oral contraceptive use. Sudden abdominal pain associated with hemodynamic instability occurred in all patients who suffered from spontaneous ruptured hepatocellular adenoma. The mean age was 41.6 years old. The preoperative assessment included liver function tests, ultrasonography and computed tomography. RESULTS: The surgical approaches were as follows: right hemihepatectomy for controlling intraperitoneal bleeding, and right extended hepatectomy and non-anatomic resection of the liver for intrahepatic hemorrhage. There were no deaths, and the postoperative complications were bile leakage and wound infection (re-operation, as well as intraperitoneal abscess (re-operation and pleural effusion. CONCLUSION: Spontaneous ruptured hepatocellular adenoma may be treated by surgery for controlling hemorrhages and stabilizing the patient, and the decision to operate depends upon both the patient's condition and the expertise of the surgical team.

  9. The Quality of Life Scale (QOLS: Reliability, Validity, and Utilization

    Directory of Open Access Journals (Sweden)

    Anderson Kathryn L

    2003-10-01

    Full Text Available Abstract The Quality of Life Scale (QOLS, created originally by American psychologist John Flanagan in the 1970's, has been adapted for use in chronic illness groups. This paper reviews the development and psychometric testing of the QOLS. A descriptive review of the published literature was undertaken and findings summarized in the frequently asked questions format. Reliability, content and construct validity testing has been performed on the QOLS and a number of translations have been made. The QOLS has low to moderate correlations with physical health status and disease measures. However, content validity analysis indicates that the instrument measures domains that diverse patient groups with chronic illness define as quality of life. The QOLS is a valid instrument for measuring quality of life across patient groups and cultures and is conceptually distinct from health status or other causal indicators of quality of life.

  10. Remaining life prediction of I and C cables for reliability assessment of NPP systems

    International Nuclear Information System (INIS)

    Santhosh, T.V.; Ghosh, A.K.; Fernandes, B.G.

    2012-01-01

    Highlights: ► A framework for time dependent reliability prediction of I and C cables for use in PSA of NPP has been developed using stress–strength interference theory. ► The proposed methodology has been illustrated with the accelerated thermal aging data on a typical XLPE cable. ► The behavior of insulation resistance when the degradation process is linear or exponential has also been modeled. ► The reliability index or probability of failure obtained from this approach can be used in system reliability evaluation to account for cable aging for PSA of NPP. - Abstract: Instrumentation and control (I and C) cables are one of the most important components in nuclear power plants (NPPs) because they provide power to safety-related equipment and also to transmit signals to and from various controllers to perform safety operations. I and C cables in NPP are subjected to a variety of aging and degradation stressors that can produce immediate degradation or aging-related mechanisms causing the degradation of cable components over time. Although, there exits several life estimation techniques, currently there is no any standard methodology or an approach toward estimating the time dependent reliability of I and C cables that can be directly used in probabilistic safety assessment (PSA) applications. Hence, the objective of this study is to develop an approach to estimate and confirm the continued acceptable margin in cable insulation life over time subjected to aging. This paper presents a framework based on the structural reliability theory to quantify the life time of I and C cable subjecting to thermal aging. Since cross-linked polyethylene (XLPE) cables are extensively being used in Indian NPPs, the remaining life time evaluations have been carried out for a typical XLPE cable. However, the methodology can be extended to other cables such as polyvinyl chloride (PVC), ethylene propylene rubber (EPR), etc.

  11. Space Shuttle Rudder Speed Brake Actuator-A Case Study Probabilistic Fatigue Life and Reliability Analysis

    Science.gov (United States)

    Oswald, Fred B.; Savage, Michael; Zaretsky, Erwin V.

    2015-01-01

    The U.S. Space Shuttle fleet was originally intended to have a life of 100 flights for each vehicle, lasting over a 10-year period, with minimal scheduled maintenance or inspection. The first space shuttle flight was that of the Space Shuttle Columbia (OV-102), launched April 12, 1981. The disaster that destroyed Columbia occurred on its 28th flight, February 1, 2003, nearly 22 years after its first launch. In order to minimize risk of losing another Space Shuttle, a probabilistic life and reliability analysis was conducted for the Space Shuttle rudder/speed brake actuators to determine the number of flights the actuators could sustain. A life and reliability assessment of the actuator gears was performed in two stages: a contact stress fatigue model and a gear tooth bending fatigue model. For the contact stress analysis, the Lundberg-Palmgren bearing life theory was expanded to include gear-surface pitting for the actuator as a system. The mission spectrum of the Space Shuttle rudder/speed brake actuator was combined into equivalent effective hinge moment loads including an actuator input preload for the contact stress fatigue and tooth bending fatigue models. Gear system reliabilities are reported for both models and their combination. Reliability of the actuator bearings was analyzed separately, based on data provided by the actuator manufacturer. As a result of the analysis, the reliability of one half of a single actuator was calculated to be 98.6 percent for 12 flights. Accordingly, each actuator was subsequently limited to 12 flights before removal from service in the Space Shuttle.

  12. Reliability and service life of wood structures and buildings

    OpenAIRE

    Zdeňka Havířová; Pavel Kubů

    2005-01-01

    Service life of constructions and buildings of wood is dependent on temperature and moisture conditions in layers of the building cladding where the wood framework is built in. Temperature/moisture conditions or the corresponding equilibrium moisture content (EMC) of the construction show considerable effects on the functional reliability of the whole building from the viewpoint of mechanical resistance and stability (ER1), energy savings and thermal protection (ER6) and hygiene, health and e...

  13. Design prediction for long term stress rupture service of composite pressure vessels

    Science.gov (United States)

    Robinson, Ernest Y.

    1992-01-01

    Extensive stress rupture studies on glass composites and Kevlar composites were conducted by the Lawrence Radiation Laboratory beginning in the late 1960's and extending to about 8 years in some cases. Some of the data from these studies published over the years were incomplete or were tainted by spurious failures, such as grip slippage. Updated data sets were defined for both fiberglass and Kevlar composite stand test specimens. These updated data are analyzed in this report by a convenient form of the bivariate Weibull distribution, to establish a consistent set of design prediction charts that may be used as a conservative basis for predicting the stress rupture life of composite pressure vessels. The updated glass composite data exhibit an invariant Weibull modulus with lifetime. The data are analyzed in terms of homologous service load (referenced to the observed median strength). The equations relating life, homologous load, and probability are given, and corresponding design prediction charts are presented. A similar approach is taken for Kevlar composites, where the updated stand data do show a turndown tendency at long life accompanied by a corresponding change (increase) of the Weibull modulus. The turndown characteristic is not present in stress rupture test data of Kevlar pressure vessels. A modification of the stress rupture equations is presented to incorporate a latent, but limited, strength drop, and design prediction charts are presented that incorporate such behavior. The methods presented utilize Cartesian plots of the probability distributions (which are a more natural display for the design engineer), based on median normalized data that are independent of statistical parameters and are readily defined for any set of test data.

  14. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  15. Unusual case of pancreatic inflammatory myofibroblastic tumor associated with spontaneous splenic rupture

    Directory of Open Access Journals (Sweden)

    Hassan Fadi K

    2010-11-01

    Full Text Available Abstract Background Spontaneous splenic rupture considered a relatively rare but life threatening. The three commonest causes of spontaneous splenic rupture are malignant hematological diseases, viral infections and local inflammatory and neoplastic disorders. We describe a unique and unusual case of inflammatory myofibroblastic tumor of the tail of pancreas presented with massively enlarged spleen and spontaneous splenic rupture. Case presentation A 19 years old male patient with no significant past medical history presented to emergency room with abdominal pain and fatigue. Massively enlarged spleen was detected. Hypotension and rapid reduction of hemoglobin level necessitated urgent laparatomy. About 1.75 liters of blood were found in abdominal cavity. A large tumor arising from the tail of pancreas and local rupture of an enlarged spleen adjacent to the tumor were detected. Distal pancreatectomy and splenectomy were performed. To our knowledge, we report the first case of massively enlarged spleen that was complicated with spontaneous splenic rupture as a result of splenic congestion due to mechanical obstruction caused by an inflammatory myofibroblastic tumor of the tail of pancreas. A review of the literature is also presented. Conclusion Inflammatory myofibroblastic tumor of the tail of pancreas should be included in the differential diagnosis of the etiological causes of massively enlarged spleen and spontaneous splenic rupture.

  16. Strength and rupture-life transitions caused by secondary carbide precipitation in HT-9 during high-temperature low-rate mechanical testing

    International Nuclear Information System (INIS)

    DiMelfi, R.J.; Gruber, E.E.; Kramer, J.M.; Hughes, T.H.

    1992-01-01

    The martensitic-ferritic alloy HT-9 is slated for long-term use as a fuel-cladding material in the Integral Fast Reactor. Analysis of published high-temperature mechanical property data suggests that secondary carbide precipitation would occur during service life causing substantial strengthening of the as-heat-treated material. Aspects of the kinetics of this precipitation process are extracted from calculations of the back stress necessary to produce the observed strengthening effect under various creep loading conditions. The resulting Arrhenius factor is shown to agree quantitatively with shifts to higher strength of crept material in reference to the intrinsic strength of HT-9. The results of very low constant strain-rate high-temperature tensile tests on as-heat-treated HT-9 that focus on the transition in strength with precipitation will be presented and related to rupture-life

  17. Long-term Creep Life Prediction for Type 316LN Stainless Steel

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Ryu, Woo Seog; Kim, Sung Ho; Lee, Chan Bok

    2007-01-01

    Since Sodium Fast Cooled Reactor (SFR) components are designed to be use for more than 30 years at a high temperature of 550 .deg. C, one of the most important properties of these components is the long term creep behavior. To accurately predict the long-term creep life of the components, it is essential to achieve reliable long-term test data beyond their design life. But, it is difficult to actually obtain long duration data because it is time-consuming work. So far, a variety of time-temperature parameters (TTPs) have been developed to predict a long-term creep life from shorter-time tests at higher temperatures. Among them, the Larson-Miller, the Orr-Sherby-Dorn, the Manson-Harferd and the Manson-Succop parameters have been typically used. None of these parameters has an overwhelming preference, and they have certain inherent restrictions imposed on their data in the application of the TTPs parameters. Meanwhile, it has been reported that the Minimum Commitment Method (MCM) proposed by Manson and Ensign has a greater flexibility for a creep rupture analysis. Thus, the MCM will be useful as another approach. Until now, the applicability of the MCM has not been investigated for type 316LN SS because of insufficient creep data. In this paper, the MCM was applied to predict a long-term creep life of type 316LN stainless steel (SS). Lots of creep rupture data was collected through literature surveys and the experimental data of KAERI. Using the short-term experimental data for under 2,000 hours, a longer-time rupture above 105 hours was predicted by the MCM at temperatures from 550 .deg. C to 800 .deg. C

  18. The diagnosis of breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse; Conrad, Carsten

    2005-01-01

    participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture...... were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89...

  19. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo-Gon, E-mail: wgkim@kaeri.re.k [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Ekaputra, I.M.W.; Park, Jae-Young [Pukyong National University, Busan 608-739 (Korea, Republic of); Kim, Min-Hwan; Kim, Yong-Wan [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2016-09-15

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  20. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Ekaputra, I.M.W.; Park, Jae-Young; Kim, Min-Hwan; Kim, Yong-Wan

    2016-01-01

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  1. Traumatic rupture of a solitary splenic hydatid cyst: A case report

    Directory of Open Access Journals (Sweden)

    Moustafa Lakis

    2015-02-01

    Full Text Available Summary: The rupture of an Echinococcus granulosus hydatid cyst in the spleen due to trauma is a rare event. In this case report we describe the case of a 39-year-old Lebanese male victim of a motor vehicle accident with a ruptured solitary splenic hydatid cyst discovered by CT scan and excised during exploratory laparotomy.Echinococcosis or hydatid disease is a parasitic infestation by the Echinococcus genus of tapeworm. The eggs of E. granulosus, a species of Echinococcus, are fecal-orally transmitted to human hosts, most often from dog feces, and manifest as cystic lesions termed hydatid. E. granulosus most commonly affects the liver (75%, lungs (15%, and rarely the spleen (2–5% [1,2]. E. granulosus is particularly endemic to cattle rearing areas of the Middle East. Infected patients most commonly present with vague abdominal pain, as a result of mass effect or spontaneous rupture of the cyst. Nevertheless, patient presentation may be due to traumatic rupture of a hydatid cyst; however, this is very rare. Herein we report a case of traumatic rupture of a solitary splenic hydatid cyst in a 39-year-old male following a motor vehicle crash, managed following the Advanced Trauma Life Support (ATLS protocol. Keywords: Echinococcus, Hydatid, Trauma, Splenectomy, Cysts, Surgery

  2. Spontaneous rupture of ovarian cystadenocarcinoma: pre- and post-rupture computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Salvadori, Priscila Silveira; Atzingen, Augusto Castelli von; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Bomfim, Lucas Novais [Universidade Tiradentes (UNIT), Maceio, AL, (Brazil)

    2015-09-15

    Epithelial ovarian tumors are the most common malignant ovarian neoplasms and, in most cases, eventual rupture of such tumors is associated with a surgical procedure. The authors report the case of a 54-year-old woman who presented with spontaneous rupture of ovarian cystadenocarcinoma documented by computed tomography, both before and after the event. In such cases, a post-rupture staging tends to be less favorable, compromising the prognosis. (author)

  3. Life Satisfaction Questionnaire (Lisat-9): Reliability and Validity for Patients with Acquired Brain Injury

    Science.gov (United States)

    Boonstra, Anne M.; Reneman, Michiel F.; Stewart, Roy E.; Balk, Gerlof A.

    2012-01-01

    The aim of this study was to determine the reliability and discriminant validity of the Dutch version of the life satisfaction questionnaire (Lisat-9 DV) to assess patients with an acquired brain injury. The reliability study used a test-retest design, and the validity study used a cross-sectional design. The setting was the general rehabilitation…

  4. Uncertainty analysis for probabilistic steam generators tube rupture in LBB applications

    Energy Technology Data Exchange (ETDEWEB)

    Durbec, V.; Pitner, P.; Pages, D. [Electricite de France, 78 - Chatou (France). Research and Development Div.; Riffard, T. [Electricite de France, 69 - Villeurbanne (France). Engineering and Construction Div.; Flesch, B. [Electricite de France, 92 - Paris la Defense (France). Generation and Transmission Div.

    1997-10-01

    Steam Generators (SG) of Pressurized Water Reactors have experienced world wide various types of tube degradations, mainly from stress corrosion cracking; because of this damage, primary-secondary leakage or tube rupture can occur. Safety against the risk of tube rupture is achieved through a combination of periodic in-service inspections (eddy current testing), surveillance of leaks during operation (leak before break concept) and tube plugging. In order to optimize the tube bundle SG maintenance, Electricite de France has developed a specific software named COMPROMIS. The model, based on probabilistic fracture mechanics makes it possible to quantify the influence of in service inspections and maintenance work on the risk of a SG Tube Rupture (SGTR), taking all significant parameters into account as random variables (initial defect size distribution, reliability of non-destructive examinations, crack initiation and propagation, critical sizes, leak before risk of break, etc...). This paper focuses on the leak rate calculation module and presents a sensitivity study of the influence of the leak before break on the conditional failure probability. (author) 8 refs.

  5. Uncertainty analysis for probabilistic steam generators tube rupture in LBB applications

    International Nuclear Information System (INIS)

    Durbec, V.; Pitner, P.; Pages, D.; Riffard, T.; Flesch, B.

    1997-10-01

    Steam Generators (SG) of Pressurized Water Reactors have experienced world wide various types of tube degradations, mainly from stress corrosion cracking; because of this damage, primary-secondary leakage or tube rupture can occur. Safety against the risk of tube rupture is achieved through a combination of periodic in-service inspections (eddy current testing), surveillance of leaks during operation (leak before break concept) and tube plugging. In order to optimize the tube bundle SG maintenance, Electricite de France has developed a specific software named COMPROMIS. The model, based on probabilistic fracture mechanics makes it possible to quantify the influence of in service inspections and maintenance work on the risk of a SG Tube Rupture (SGTR), taking all significant parameters into account as random variables (initial defect size distribution, reliability of non-destructive examinations, crack initiation and propagation, critical sizes, leak before risk of break, etc...). This paper focuses on the leak rate calculation module and presents a sensitivity study of the influence of the leak before break on the conditional failure probability. (author)

  6. Accelerated life testing and reliability of high K multilayer ceramic capacitors

    Science.gov (United States)

    Minford, W. J.

    1981-01-01

    The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

  7. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  8. Reliability and Validity of the Multidimensional Scale of Life Skills in Late Childhood

    Directory of Open Access Journals (Sweden)

    Minoru Takakura

    2013-04-01

    Full Text Available This study investigated the reliability and validity of the Multidimensional Scale of Life Skills in Late Childhood, an instrument designed to measure a concept similar to “zest for living” in late childhood. A total of 1,888 elementary school students in the 4th, 5th, and 6th grades residing in urban and suburban areas as well as in remote islands of 3 prefectures (Okinawa, Kagoshima, and Nagasaki were surveyed. On the basis of our analysis, 24 items and seven factors were extracted. These factors are problem-solving/synthesis, relationship with friends, personal manners, decision-making and future planning, self-learning, collecting and using information, and leadership. Cronbach’s alpha reliability coefficients were computed for each subscale and ranged from 0.71 to 0.87. Test-retest reliability coefficient values ranged from 0.68 to 0.79. To examine the construct validity of the scales, a goodness-of-fit model was determined by confirmatory factor analysis, and satisfactory values were found (GFI = 0.952, AGFI = 0.937, CFI = 0.966, RMSEA = 0.016. The validity of the goodness-of-fit model and the reliability of the scales indicate that the Multidimensional Scale of Life Skills in Late Childhood is an effective assessment tool.

  9. The reliability of the repair weld joints of aged high temperature components in fossil power boilers

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, Hiroyuki [Science Univ. of Tokyo (Japan); Ohtani, Ryuichi [Kyoto Univ. (Japan); Fujii, Kazuya [Japan Power Engineering and Inspection Corp., Tokyo (Japan); Yokoyama, Tomomitsu; Nishimura, Nobuhiko [Mitsubishi Heavy Industries Ltd., Tokyo (Japan); Suzuki, Komei [Japan Steel Works Ltd., Tokyo (Japan)

    1998-11-01

    It is of fundamental engineering importance to be able to give reliable assessments of the effective service life of the critical components used within fossil power plants, particularly for those operating for prolonged periods. It is common practice for such assessments to have been estimated using destructive tests, typically the stress rupture test, this having been recognized as one of the most reliable evaluation methods available. Its only drawback is that it often does not permit the component to be in use following the sampling of the test specimen without repairing. The current piece of work focuses on the reliability of the repair welds of components for specimens taken from fossil power plants, having been in service for prolonged periods. Several such repairs to welds have been made to an old power boiler, in particular to a superheater header which is fabricated from 2.25Cr-1Mo steel. Under close examination the repairs to the girth weldment showed susceptibilities of weld cracking, similar to that observed in as-manufactured material. Within the repaired region of the welded joint the microstructure, tensile properties and toughness seemed to be unaffected. The hardness attained its minimum value within the heat affected zone, HAZ of the repair weld, overlapping that of original girth weld HAZ. Furthermore, the stress rupture strength achieved its minimum value at the same position taking on the same value as the strength associated with the aged girth welded joint. (orig.)

  10. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  11. Unique case of esophageal rupture after a fall from height

    Directory of Open Access Journals (Sweden)

    van Berge Henegouwen Mark I

    2009-12-01

    Full Text Available Abstract Background Traumatic ruptures of the esophagus are relatively rare. This condition is associated with high morbidity and mortality. Most traumatic ruptures occur after motor vehicle accidents. Case Presentation We describe a unique case of a 23 year old woman that presented at our trauma resuscitation room after a fall from 8 meters. During physical examination there were no clinical signs of life-threatening injuries. She did however have a massive amount of subcutaneous emphysema of the chest and neck and pneumomediastinum. Flexible laryngoscopy revealed a lesion in the upper esophagus just below the level of the upper esophageal sphincter. Despite preventive administration of intravenous antibiotics and nutrition via a nasogastric tube, the patient developed a cervical abscess, which drained spontaneously. Normal diet was gradually resumed after 2.5 weeks and the patient was discharged in a reasonable condition 3 weeks after the accident. Conclusions This case report presents a high cervical esophageal rupture without associated local injuries after a fall from height.

  12. Comparison between arthroscopy and magnetic resonance studies of rupture of the anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Torregrosa, A.; Higueras, V.; Marti-Bonmati, L.; Casillas, C.; Sanfeliu, M.

    1999-01-01

    To compare the reliability of magnetic resonance (MR) in the diagnosis of rupture of the anterior cruciate ligament (ACL) with that of arthroscopy in a large series of patients. A series of 149 patients underwent arthroscopy and MR study of the knee. The condition of the ACL was classified as normal, partial rupture (increased signal in the ligament with integral hypointense fibers) or complete rupture (complete interruption or failure to visualize the ligament). The agreement (kappa), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. MR images of ACL were normal in 114 of 116 normal cases; partial rupture was observed in 4 cases (versus 3 in arthroscopy) and complete rupture in 31 (versus 30 in arthroscopy). The agreement was excellent (kappa: 0.93; p < 0.001). For the diagnosis of normal ACL, the sensitivity of MR was 1, the specificity 0.98, the PPV 0.94 and the NPV 1. For the diagnosis of partial rupture, the sensitivity was 0.67, the specificity 0.98, the PPV 0.50 and the NPV 0.99. For complete rupture, the sensitivity was 0.97, the specificity 0.98, the PPV 0.94 and the NPV 0.99. The high sensitivity and specificity of MR observed in the diagnosis of integral ACL is somewhat reduced in cases of complete rupture and even lower in cases of partial rupture. It is important to differentiate the degree of rupture since the therapeutic management of the patient differs. (Author) 18 refs

  13. Hepatic rupture in preeclampsia

    International Nuclear Information System (INIS)

    Winer-Muram, H.T.; Muram, D.; Salazar, J.; Massie, J.D.

    1985-01-01

    The diagnosis of hepatic rupture in patients with pregnancy-induced hypertension (preeclampsia and eclampsia) is rarely made preoperatively. Diagnostic imaging can be utilized in some patients to confirm the preoperative diagnosis. Since hematoma formation precedes hepatic rupture, then, when diagnostic modalities such as sonography and computed tomography identify patients with hematomas, these patients are at risk of rupture, and should be hospitalized until the hematomas resolve

  14. Spontaneous liver rupture in pregnancy complicating HELLP syndrome: case report

    Directory of Open Access Journals (Sweden)

    Sariyeh Golmahammadlou

    2014-10-01

    Conclusion: Spontaneous liver rupture associated with HELLP syndrome is a rare and life-threatening complication of pregnancy. Unruptured liver hematoma is also a rare condition during pregnancy with a very difficult diagnosis. Using clinical diagnostic tests such as CT scan or MRI would be helpful to improve clinical outcomes.

  15. Influence of flowing sodium on creep deformation and rupture behaviour of 316L(N) austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Laha, K.; Mathew, M.D. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Vijayaraghavan, S.; Shanmugavel, M.; Rajan, K.K. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Jayakumar, T. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2012-08-15

    The influence of flowing sodium on creep deformation and rupture behaviour of AISI 316L(N) austenitic stainless steel has been investigated at 873 K over a stress range of 235-305 MPa. The results were compared with those obtained from testing in air environment. The steady state creep rates of the material were not influenced appreciably by the testing environments. The time to onset of tertiary stage of creep deformation was delayed in sodium environment. The creep-rupture lives of the material increased in sodium environment, which became more pronounced at lower applied stresses. The increase in rupture life of the material in flowing sodium was accompanied by an increase in rupture ductility. The creep damage on specimen surface as well as inside the specimen was less in specimen tested in sodium. SEM fractographic investigation revealed predominantly transgranular dimple failure for the specimen tested in sodium, whereas predominantly intergranular creep failure was observed in the air tested specimens. Almost no oxidation was observed in the specimens creep tested in the sodium environment. Absence of oxidation and less creep damage cavitation extended the secondary state in liquid sodium tests and lead to increase in creep rupture life and ductility of the material as compared to in air.

  16. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Herborn, Christoph U. [Institute of Diagnostic Radiology, University Hospital, Zuerich (Switzerland); Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45128 Essen (Germany); Marincek, Borut; Erfmann, Daniel; Kubik-Huch, Rahel A. [Institute of Diagnostic Radiology, University Hospital, Zuerich (Switzerland); Meuli-Simmen, Claudia; Wedler, Volker [Department of Surgery, Clinic for Reconstructive Surgery, University Hospital, Zurich (Switzerland); Bode-Lesniewska, Beate [Department of Pathology, University Hospital, Zurich (Switzerland)

    2002-09-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction. (orig.)

  17. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy

    International Nuclear Information System (INIS)

    Herborn, Christoph U.; Marincek, Borut; Erfmann, Daniel; Kubik-Huch, Rahel A.; Meuli-Simmen, Claudia; Wedler, Volker; Bode-Lesniewska, Beate

    2002-01-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction. (orig.)

  18. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy.

    Science.gov (United States)

    Herborn, Christoph U; Marincek, Borut; Erfmann, Daniel; Meuli-Simmen, Claudia; Wedler, Volker; Bode-Lesniewska, Beate; Kubik-Huch, Rahel A

    2002-09-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction.

  19. Life Cycle Management for Equipments in Nuclear Plants Based on Reliability

    International Nuclear Information System (INIS)

    Wang Dalin; Sun Jinlong

    2012-01-01

    Life cycle management model based on reliability includes two parts: obtaining failure rate function and founding cost-oriented model to solve. It is actually a single objective programming whose optimal solution is the most economical replacement period. Parameters of failure rate function are estimated by Weibull process fitting with the method of maximum likelihood. The objective function of the model is life-cost function where the dependent variable is replacement period T, with the constraints of failure rate or availability. After foundation of LCM model, we solve it to find the optimal replacement period for the equipments. (author)

  20. Assessing reliability and useful life of containers for disposal of irradiated fuel waste

    International Nuclear Information System (INIS)

    Doubt, G.

    1984-06-01

    Metal containers for fuel waste isolation are to be designed to last at least 500 years to provide a redundant barrier during the decay period of the high activity components of the waste. To meet the long-life requirement, containers must have a very low failure rate during the design mission, a low incidence of 'juvenile failures' due to undetected defects, and resistance to progressive deterioration from environmental processes. This paper summarizes studies to determine: (1) precedent for low failure rates and relevance to container longevity; (b) the likelihood of initial defects perforating the container before or shortly after emplacement, and estimates of material defect distribution; (c) the utility of reliability analysis techniques for estimating reliability and life of fuel waste containers; (d) other approaches to estimating container longevity and failure versus time distribution

  1. A Note on the Score Reliability for the Satisfaction with Life Scale: An RG Study

    Science.gov (United States)

    Vassar, Matt

    2008-01-01

    The purpose of the present study was to meta-analytically investigate the score reliability for the Satisfaction With Life Scale. Four-hundred and sixteen articles using the measure were located through electronic database searches and then separated to identify studies which had calculated reliability estimates from their own data. Sixty-two…

  2. TURKISH VERSION QUALITY OF LIFE IN ESSENTIAL TREMOR QUESTIONNAIRE (QUEST): VALIDITY AND RELIABILITY STUDY.

    Science.gov (United States)

    Güler, Sibel; Turan, F Nesrin

    2015-09-30

    Our aim was to translate the Quality of Life in Essential Tremor Questionnaire (QUEST) advanced by Troster (2005) and to analyse the validity and reliability of this questionnaire. Two hundred twelve consecutive patients with essential tremor (ET) and forty-three control subjects were included in the study. Permission for the translation and validation of the QUEST scale was obtained. The translation was performed according to the guidelines provided by the publisher. After the translation, the final version of the scale was administered to both groups to determine its reliability and validity. The QUEST Physical, Psychosocial, communication, Hobbies/leisure and Work/finance scores were 0.967, 0.968, 0.933, 0.964 and 0.925, respectively. There were good correlations between each of the QUEST scores that were indicative of good internal consistency. Additionally, we observed that all of the QUEST scores were most strongly related to the right and left arms (p=0.0001). However, we observed that all of the QUEST scores were weakly related to the voice, head and right leg (p=0.0001). These findings support the notion that the Turkish version of the Quality of Life in Essential Tremor (QUEST) questionnaire is a valid and reliable tool for the assessment of the quality of life of patients with ET.

  3. Endometriosis-related spontaneous diaphragmatic rupture.

    Science.gov (United States)

    Triponez, Frédéric; Alifano, Marco; Bobbio, Antonio; Regnard, Jean-François

    2010-10-01

    Non-traumatic, spontaneous diaphragmatic rupture is a rare event whose pathophysiology is not known. We report the case of endometriosis-related spontaneous rupture of the right diaphragm with intrathoracic herniation of the liver, gallbladder and colon. We hypothesize that the invasiveness of endometriotic tissue caused diaphragm fragility, which finally lead to its complete rupture without traumatic event. The treatment consisted of a classical management of diaphragmatic rupture, with excision of the endometriotic nodule followed by medical ovarian suppression for six months.

  4. Real-Time Detection of Rupture Development: Earthquake Early Warning Using P Waves From Growing Ruptures

    Science.gov (United States)

    Kodera, Yuki

    2018-01-01

    Large earthquakes with long rupture durations emit P wave energy throughout the rupture period. Incorporating late-onset P waves into earthquake early warning (EEW) algorithms could contribute to robust predictions of strong ground motion. Here I describe a technique to detect in real time P waves from growing ruptures to improve the timeliness of an EEW algorithm based on seismic wavefield estimation. The proposed P wave detector, which employs a simple polarization analysis, successfully detected P waves from strong motion generation areas of the 2011 Mw 9.0 Tohoku-oki earthquake rupture. An analysis using 23 large (M ≥ 7) events from Japan confirmed that seismic intensity predictions based on the P wave detector significantly increased lead times without appreciably decreasing the prediction accuracy. P waves from growing ruptures, being one of the fastest carriers of information on ongoing rupture development, have the potential to improve the performance of EEW systems.

  5. Rupture of Al matrix in U-Mo/Al dispersion fuel by fission induced creep

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gwan Yoon; Sohn, Dong Seong [UNIST, Daejeon (Korea, Republic of); Kim, Yeon Soo [Argonne National Laboratory, Argonnge (United States); Lee, Kyu Hong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This phenomenon was found specifically in the dispersion fuel plate with Si addition in the Al matrix to suppress interaction layer (IL) formation between UMo and Al. It is known that the stresses induced by fission induced swelling in U-Mo fuel particles are relieved by creep deformation of the IL, surrounding the fuel particles, that has a much higher creep rate than the Al matrix. Thus, when IL growth is suppressed, the stress is instead exerted on the Al matrix. The observed rupture in the Al matrix is believed to be caused when the stress exceeded the rupture strength of the Al matrix. In this study, the possibility of creep rupture of the Al matrix between the neighboring U-Mo fuel particles was examined using the ABAQUS finite element analysis (FEA) tool. The predicted rupture time for a plate was much shorter than its irradiation life indicating a rupture during the irradiation. The higher stress leads Al matrix to early creep rupture in this plate for which the Al matrix with lower creep strain rate does not effectively relieve the stress caused by the swelling of the U-Mo fuel particles. For the other plate, no rupture was predicted for the given irradiation condition. The effect of creeping of the continuous phase on the state of stress is significant.

  6. The effect of tube rupture location on the consequences of multiple steam generator tube rupture event

    International Nuclear Information System (INIS)

    Jeong, Ji Hwan; Kweon, Young Chul

    2002-01-01

    A multiple steam generator tube rupture (MSGTR) event has never occurred in the commercial operation of nuclear reactors while single steam generator tube rupture (SGTR) events are reported to occur every 2 years. As there has been no occurrence of a MSGTR event, the understanding of transients and consequences of this event is very limited. In this study, a postulated MSGTR event in an advanced power reactor 1400 (APR 1400) is analyzed using the thermal-hydraulic system code, MARS1.4. The APR 1400 is a two-loop, 3893 MWt, PWR proposed to be built in 2010. The present study aims to understand the effects of rupture location in heat transfer tubes following a MSGTR event. The effects of five tube rupture locations are compared with each other. The comparison shows that the response of APR1400 allows the shortest time for operator action following a tube rupture in the vicinity of the hot-leg side tube sheet and allows the longest time following a tube rupture at the tube top. The MSSV lift time for rupture at the tube-top is evaluated as 24.5% larger than that for rupture at the hot-leg side tube sheet

  7. Creep Deformation and Rupture Behavior of Single- and Dual-Pass 316LN Stainless-Steel-Activated TIG Weld Joints

    Science.gov (United States)

    Vijayanand, V. D.; Vasudevan, M.; Ganesan, V.; Parameswaran, P.; Laha, K.; Bhaduri, A. K.

    2016-06-01

    Creep deformation and rupture behavior of single-pass and dual-pass 316LN stainless steel (SS) weld joints fabricated by an autogenous activated tungsten inert gas welding process have been assessed by performing metallography, hardness, and conventional and impression creep tests. The fusion zone of the single-pass joint consisted of columnar zones adjacent to base metals with a central equiaxed zone, which have been modified extensively by the thermal cycle of the second pass in the dual-pass joint. The equiaxed zone in the single-pass joint, as well as in the second pass of the dual-pass joint, displayed the lowest hardness in the joints. In the dual-pass joint, the equiaxed zone of the first pass had hardness comparable to the columnar zone. The hardness variations in the joints influenced the creep deformation. The equiaxed and columnar zone in the first pass of the dual-pass joint was more creep resistant than that of the second pass. Both joints possessed lower creep rupture life than the base metal. However, the creep rupture life of the dual-pass joint was about twofolds more than that of the single-pass joint. Creep failure in the single-pass joint occurred in the central equiaxed fusion zone, whereas creep cavitation that originated in the second pass was blocked at the weld pass interface. The additional interface and strength variation between two passes in the dual-pass joint provides more restraint to creep deformation and crack propagation in the fusion zone, resulting in an increase in the creep rupture life of the dual-pass joint over the single-pass joint. Furthermore, the differences in content, morphology, and distribution of delta ferrite in the fusion zone of the joints favors more creep cavitation resistance in the dual-pass joint over the single-pass joint with the enhancement of creep rupture life.

  8. Analysis and Application of Reliability

    International Nuclear Information System (INIS)

    Jeong, Hae Seong; Park, Dong Ho; Kim, Jae Ju

    1999-05-01

    This book tells of analysis and application of reliability, which includes definition, importance and historical background of reliability, function of reliability and failure rate, life distribution and assumption of reliability, reliability of unrepaired system, reliability of repairable system, sampling test of reliability, failure analysis like failure analysis by FEMA and FTA, and cases, accelerated life testing such as basic conception, acceleration and acceleration factor, and analysis of accelerated life testing data, maintenance policy about alternation and inspection.

  9. Parametric and semiparametric models with applications to reliability, survival analysis, and quality of life

    CERN Document Server

    Nikulin, M; Mesbah, M; Limnios, N

    2004-01-01

    Parametric and semiparametric models are tools with a wide range of applications to reliability, survival analysis, and quality of life. This self-contained volume examines these tools in survey articles written by experts currently working on the development and evaluation of models and methods. While a number of chapters deal with general theory, several explore more specific connections and recent results in "real-world" reliability theory, survival analysis, and related fields.

  10. Technical report on the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1993-05-01

    Japan Atomic Energy Research Institute (JAERI) conducts Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan (STA) under the auspices of the special account law for electric power development promotion. The purpose of these tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the light water reactor power plants. The tests with large experimental facilities had ended already in 1990. Presently piping reliability analysis by the probabilistic fracture mechanics method is being done. Until now annual reports concerning the proving tests were produced and submitted to STA, whereas this report summarizes the test results done during these 16 years. Objectives of the piping reliability proving tests are to prove that the primary piping of the light water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location even if it ruptured suddenly. To attain these objectives (i) pipe fatigue tests, (ii) unstable pipe fracture tests, (iii) pipe rupture tests and also the analyses by computer codes were done. After carrying out these tests, it is verified that the piping is reliable throughout the service period. The authors of this report are T. Isozaki, K. Shibata, S. Ueda, R. Kurihara, K. Onizawa and A. Kohsaka. The parts they wrote are shown in contents. (author)

  11. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  12. Rupture of the Pitáycachi Fault in the 1887 Mw 7.5 Sonora, Mexico earthquake (southern Basin-and-Range Province): Rupture kinematics and epicenter inferred from rupture branching patterns

    Science.gov (United States)

    Suter, Max

    2015-01-01

    During the 3 May 1887 Mw 7.5 Sonora earthquake (surface rupture end-to-end length: 101.8 km), an array of three north-south striking Basin-and-Range Province faults (from north to south Pitáycachi, Teras, and Otates) slipped sequentially along the western margin of the Sierra Madre Occidental Plateau. This detailed field survey of the 1887 earthquake rupture zone along the Pitáycachi fault includes mapping the rupture scarp and measurements of surface deformation. The surface rupture has an endpoint-to-endpoint length of ≥41.0 km, dips 70°W, and is characterized by normal left-lateral extension. The maximum surface offset is 487 cm and the mean offset 260 cm. The rupture trace shows a complex pattern of second-order segmentation. However, this segmentation is not expressed in the 1887 along-rupture surface offset profile, which indicates that the secondary segments are linked at depth into a single coherent fault surface. The Pitáycachi surface rupture shows a well-developed bipolar branching pattern suggesting that the rupture originated in its central part, where the polarity of the rupture bifurcations changes. Most likely the rupture first propagated bilaterally along the Pitáycachi fault. The southern rupture front likely jumped across a step over to the Teras fault and from there across a major relay zone to the Otates fault. Branching probably resulted from the lateral propagation of the rupture after breaching the seismogenic part of the crust, given that the much shorter ruptures of the Otates and Teras segments did not develop branches.

  13. Biomechanical rupture risk assessment of abdominal aortic aneurysms based on a novel probabilistic rupture risk index.

    Science.gov (United States)

    Polzer, Stanislav; Gasser, T Christian

    2015-12-06

    A rupture risk assessment is critical to the clinical treatment of abdominal aortic aneurysm (AAA) patients. The biomechanical AAA rupture risk assessment quantitatively integrates many known AAA rupture risk factors but the variability of risk predictions due to model input uncertainties remains a challenging limitation. This study derives a probabilistic rupture risk index (PRRI). Specifically, the uncertainties in AAA wall thickness and wall strength were considered, and wall stress was predicted with a state-of-the-art deterministic biomechanical model. The discriminative power of PRRI was tested in a diameter-matched cohort of ruptured (n = 7) and intact (n = 7) AAAs and compared to alternative risk assessment methods. Computed PRRI at 1.5 mean arterial pressure was significantly (p = 0.041) higher in ruptured AAAs (20.21(s.d. 14.15%)) than in intact AAAs (3.71(s.d. 5.77)%). PRRI showed a high sensitivity and specificity (discriminative power of 0.837) to discriminate between ruptured and intact AAA cases. The underlying statistical representation of stochastic data of wall thickness, wall strength and peak wall stress had only negligible effects on PRRI computations. Uncertainties in AAA wall stress predictions, the wide range of reported wall strength and the stochastic nature of failure motivate a probabilistic rupture risk assessment. Advanced AAA biomechanical modelling paired with a probabilistic rupture index definition as known from engineering risk assessment seems to be superior to a purely deterministic approach. © 2015 The Author(s).

  14. Effect of Environment on Stress-Rupture Behavior of a Carbon Fiber-Reinforced Silicon Carbide (C/SiC) Ceramic Matrix Composite

    Science.gov (United States)

    Verrilli, Michael J.; Opila, Elizabeth J.; Calomino, Anthony; Kiser, J. Douglas

    2002-01-01

    Stress-rupture tests were conducted in air, vacuum, and steam-containing environments to identify the failure modes and degradation mechanisms of a carbon fiber-reinforced silicon carbide (C/SiC) composite at two temperatures, 600 and 1200 C. Stress-rupture lives in air and steam containing environments (50 - 80% steam with argon) are similar for a composite stress of 69 MPa at 1200 C. Lives of specimens tested in a 20% steam/argon environment were about twice as long. For tests conducted at 600 C, composite life in 20% steam/argon was 20 times longer than life in air. Thermogravimetric analysis of the carbon fibers was conducted under similar conditions to the stress-rupture tests. The oxidation rate of the fibers in the various environments correlated with the composite stress-rupture lives. Examination of the failed specimens indicated that oxidation of the carbon fibers was the primary damage mode for specimens tested in air and steam environments at both temperatures.

  15. Does the Lever Sign Test Have Added Value for Diagnosing Anterior Cruciate Ligament Ruptures?

    Science.gov (United States)

    Lichtenberg, Miranda C.; Koster, Christiaan H.; Teunissen, Lennart P.J.; Oosterveld, Frits G.J.; Harmsen, Annelieke M.K.; Haverkamp, Daniel; Hoornenborg, Daniel; Berg, Robert P.; Bloemers, Frank W.; Faber, Irene R.

    2018-01-01

    Background: Diagnosing an anterior cruciate ligament (ACL) rupture based on a physical examination remains a challenge for both surgeons and physical therapists. The lever sign test was developed to overcome the practical limitations of other tests and to optimize diagnosis. An evaluation of the measurement properties of the lever sign test is needed to make adequate interpretations in practice. Purpose: To evaluate the reliability and diagnostic value of the lever sign test. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: A total of 94 patients were recruited between November 2014 and July 2016. Patients were included if they were at least 16 years old, suffered from knee trauma, and had indications for knee arthroscopic surgery. Lever sign, anterior drawer, Lachman, and pivot-shift test outcomes were examined by an orthopaedic/trauma surgeon and a physical therapist. A test-retest design was used to investigate interrater reliability. Moreover, the lever sign test outcomes, alone and in combination with the other diagnostic tests, were compared with arthroscopic results, which served as the gold standard for the test’s diagnostic value. Results: The lever sign test and pivot-shift test had kappa values exceeding 0.80 for interrater reliability. The kappa values for the anterior drawer test and Lachman test were 0.80 and 0.77, respectively. The lever sign test showed the highest specificity (100%) and the lowest sensitivity (39%) when compared with the other 3 tests. Moreover, its positive and negative predictive values were 100% and 65%, respectively, while an accuracy of 71% was calculated. Clustering the lever sign test parallel with the other 3 tests resulted in the highest accuracy of 91%. Conclusion: The lever sign test appears to have high interrater reliability and is the most specific test, showing a maximal positive predictive value. A positive lever sign test result indicates an ACL rupture. These results support the added value

  16. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  17. Splenic rupture and intracranial haemorrhage in a haemophilic neonate: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Ibrahim Adamu

    2012-01-01

    Full Text Available Splenic rupture and intracranial haemorrhage are life-threatening conditions infrequently encountered in neonates without history of birth trauma. External manifestations of birth trauma; namely, capput succadeneum and cephalhematoma, when present raise suspicions for more serious intracranial or visceral damage. Rupture of normal spleen without an obvious source of trauma in haemophilic neonate is a rare event. The concurrence of both conditions and the unusual presentation make this case a rare one that is seldom encountered in the literature. Additionally, when splenic rupture occurs, the consensus is to employ all non-operative techniques aimed at salvaging the spleen, thus avoiding the immune-compromised state associated with splenectomy. However, in this case, we present a 3-day-old male with family history of haemophilia A, who was diagnosed with splenic rupture and bilateral subdural haematomas and underwent splenectomy, albeit with post-operative complications, in light of haemodynamic instability and high ongoing transfusion requirements.

  18. A summary of methods of predicting reliability life of nuclear equipment with small samples

    International Nuclear Information System (INIS)

    Liao Weixian

    2000-03-01

    Some of nuclear equipment are manufactured in small batch, e.g., 1-3 sets. Their service life may be very difficult to determine experimentally in view of economy and technology. The method combining theoretical analysis with material tests to predict the life of equipment is put forward, based on that equipment consists of parts or elements which are made of different materials. The whole life of an equipment part consists of the crack forming life (i.e., the fatigue life or the damage accumulation life) and the crack extension life. Methods of predicting machine life has systematically summarized with the emphasis on those which use theoretical analysis to substitute large scale prototype experiments. Meanwhile, methods and steps of predicting reliability life have been described by taking into consideration of randomness of various variables and parameters in engineering. Finally, the latest advance and trends of machine life prediction are discussed

  19. Assessment of the residual time to rupture of fuel pins after reactor core disturbances using the Lebensanteil rule

    International Nuclear Information System (INIS)

    Schaefer, L.; Wassilew, C.

    1992-01-01

    An important aspect of disturbances in the reactor core is the way in which they affect the service life of fuel rod cladding tubes. This factor also determines whether and how long the reactor core can be continued in operation, i.e., matters of safety and economy are involved. Potential disturbances of the reactor core affect the fuel rod cladding tubes as increases in temperature and, sometimes, as mechanical stresess for limited periods of time. As thermomechanical stresses acting on a cladding tube also give rise to creep events which may limit the service life of fuel elements, it is important to know how much creep life or time to rupture is consumed in the course of a core disturbance, and what the residual life is. For this purpose, the times to rupture before and during the accident must be added up and the balance calculated. As a rule of computation, the Lebensanteil rule is used in its form expressing the time to rupture of creeping solids. The simulation of accidents with unirradiated cladding tubes revealed a drastic decrease of the residual time to rupture in those cases in which the cladding material had recrystallized. On the other hand, because of its structural stability, irradiated material turned out to be almost insensitive even under extremely severe accident conditions. The materials data so far available are sufficient for useful estimates. Presuming one of the damage accumulating processes of the creeping cladding material is predominant, there are no further validity limiting ranges concerning kind of accident, loading condition, cladding material and so on. (orig.)

  20. Long-time rupture strength and creep behaviour of welded joints on heat-resistant CrMoV steels with 1 and 12% chrome

    International Nuclear Information System (INIS)

    Maier, G.; Maile, K.; Theofel, H.

    1985-01-01

    Power plant components in the creep range are damaged frequently in the weld joint zones. The investigation concentrated therefore on the reliability of the information supplied by tests on small- and large-size samples. Creep rupture tests of dissimilar welded joints (1% with 12% chrome) with variations of heat input and weld metal have been conducted. At creep rupture times of about 10 4 h all joints failed in the outside heat affected zone of the weaker base metal. Large-size samples, proved in comparison at same stresses, showed distinctly longer times to rupture. (orig.) [de

  1. Acute appendiceal abscess and atraumatic splenic rupture: A case of dual pathology.

    Science.gov (United States)

    Ananthavarathan, Piriyankan; Patel, Kamlesh; Doran, Catherine; Suggett, Nigel

    2016-01-01

    Atraumatic splenic rupture is a rare surgical emergency that is often attributed to neoplastic or infectious causes. Rarely, it has been identified to also occur in the setting of an acute severe sepsis and in cases of pelvic or splenic abscess formation post-appendicectomy. However, to our knowledge, the co-presentation of acute appendiceal abscess and splenic rupture has not been previously described. We present the case of a 67-year old male with decompensating haemorrhagic shock secondary to atraumatic splenic rupture on a background of an inadequately treated complicated appendicitis originally managed as diverticulitis with antibiotics in the community. Intra-operatively, in addition to a de-gloved, ruptured spleen; an acutely inflamed appendiceal abscess was also identified. A concomitant splenectomy, washout and appendicectomy and was therefore performed. Histopathological examination revealed a normal spleen with a stripped capsular layer. Mucosal ulceration, transmural inflammation and serositis of the appendix appeared to be consistent with acute appendicitis. Our case demonstrates how inadequately treated sepsis may predispose to an acute presentation of splenic rupture with associated haemorrhagic shock; which may initially be interpreted as septic shock. However, we demonstrate how insults such as sepsis and haemorrhagic shock may co-exist warranting careful consideration of possible dual pathologies in complex presentations which may be life-threatening. While the causal relationship between acute appendicitis and atraumatic spontaneous splenic rupture remains unclear, our case considers and highlights the importance of considering dual pathology in patients presenting in the acute setting. Copyright © 2016. Published by Elsevier Ltd.

  2. A Chinese version of the City of Hope Quality of Life-Ostomy Questionnaire: validity and reliability assessment.

    Science.gov (United States)

    Gao, Wenjun; Yuan, Changrong; Wang, Jichuan; Du, Jiarui; Wu, Huiqiao; Qian, Xiaojie; Hinds, Pamela S

    2013-01-01

    The City of Hope Quality of Life-Ostomy Questionnaire is a widely accepted scale to assess quality of life in ostomy patients. However, the validity and reliability of the Chinese version (C-COH) have not been studied. The objective of the study was to assess the validity and reliability of the C-COH among ostomy patients sampled from Shanghai from August 2010 to June 2011. Content validity was examined based on the reviews of a panel of 10 experts; test-retest was conducted to assess the item reliabilities of the scale; a pilot sample (n = 274) was selected to explore the factorial structure of the C-COH using exploratory factor analysis; a validation sample (n = 370) was selected to confirm the findings from the exploratory study using confirmatory factor analysis (CFA). Statistical package SPSS version 16.0 was used for the exploratory factor analysis, and Amos 17.0 was used for the CFA. The C-COH was developed by modifying 1 item and excluding 11 items from the original scale. Four factors/subscales (physical well-being, psychological well-being, social well-being, and spiritual well-being) were identified and confirmed in the C-COH The scale reliabilities estimated from the CFA results for the 4 subscales were 0.860, 0.885, 0.864, and 0.686, respectively. Findings support the reliability and validity of the C-COH. The C-COH could be a useful measure of the level of quality of life among Chinese patients with a stoma and may provide important intervention implications for healthcare providers to help improve the life quality of patients with a stoma.

  3. Evaluation of creep rupture property of high strength ferritic/martensitic steel (PNC-FMS)

    International Nuclear Information System (INIS)

    Uehira, Akihiro; Mizuno, Tomoyasu; Ukai, Shigeharu; Yoshida, Eiichi

    1999-04-01

    High Strength Ferritic/Martensitic Steel (PNC-FMS : 11Cr-0.5Mo-2W,Nb,V), developed by JNC, is one of the candidate materials for the long-life core of large-scale fast breeder reactor. The material design base standard (tentative) of PNC-FMS was established and the creep rupture strength reduction factor in the standard was determined in 1992. This factor was based on only evaluation of decarburization effect on tensile strength after sodium exposure. In this study, creep rupture properties of PNC-FMS under out of pile sodium exposure and in pile were evaluated, using recent test results as well as previous ones. The evaluation results are summarized as follows : a. Decarburization rate constant of pressurized tubes under sodium exposure is identical with stress free specimens. b. In case of the same decarburization content under out of pile sodium exposure, creep strength tends to decrease more significantly than tensile strength. c. Creep strength under out of pile sodium exposure showed significant decrease in high temperature and long exposure time, but in pile (MOTA) creep strength showed little decrease. A new creep rupture strength reduction factor, which is the ratio of creep rupture strength under sodium exposure or in pile to in air, was made by correlating the creep rupture strength. This new method directly using the ratio of creep rupture strength was evaluated and discussed from the viewpoint of design applicability, compared with the conventional method based on decarburization effect on tensile strength. (author)

  4. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    Michalak, Maciej; Żurada, Anna; Biernacki, Maciej; Zygmunt, Kozielec

    2010-01-01

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8 th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  5. Nondestructive Evaluation and Monitoring Results from COPV Accelerated Stress Rupture Testing, NASA White Sands Test Facility (WSTF)

    Science.gov (United States)

    Saulsberry Regor

    2010-01-01

    Develop and demonstrate NDE techniques for real-time characterization of CPVs and, where possible, identification of NDE capable of assessing stress rupture related strength degradation and/or making vessel life predictions (structural health monitoring or periodic inspection modes). Secondary: Provide the COPV user and materials community with quality carbon/epoxy (C/Ep) COPV stress rupture progression rate data. Aid in modeling, manufacturing, and application of COPVs for NASA spacecraft.

  6. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  7. Effect of some thermomechanical variables on plastic flow and creep-rupture of type 304 stainless steel at 5930C

    International Nuclear Information System (INIS)

    Swindeman, R.W.

    1977-01-01

    As part of an effort to examine sources of variability in the creep-rupture behavior of type 304 stainless steel, specimens subjected to a variety of prior thermomechanical treatments were tested. Included were different reannealing temperatures, cooling rates, types of prior straining, and a 24-hr age at 816 0 C. Two product forms of a single heat (heat 9T2796) were involved, and most testing was at 593 0 C. For material with coarse grain size, reannealing temperature had no pronounced influence. However, slow cooling rates and the 816 0 C aging significantly extended the rupture life. On the other hand, cold working by an equivalent of 4% tensile strain had very little influence on rupture life. Slow cooling or aging increased rupture life as a result of greatly improved creep ductility. This finding is consistent with similar observations in the literature for this and other stainless steels, and is believed to be due to the development of coarse, beneficial carbides on grain boundaries before stressing. The creep response in the primary and secondary stages was influenced by nearly all the thermomechanical treatments, but the variability in the response at relatively high stresses was scarcely greater than the variability observed in multiple tests on specimens having a common thermomechanical history. 10 figures, 1 table

  8. Reliability of the Life Satisfaction Questionnaire to assess patients with chronic musculoskeletal pain

    NARCIS (Netherlands)

    Boonstra, Anne M.; Reneman, Michiel F.; Posthumus, Jitze B.; Stewart, Roy E.; Schiphorst Preuper, Henrica R.

    The aim of this study was to determine the reliability of the Life Satisfaction Questionnaire, Dutch version (LSQ-DV), to assess chronic pain patients. The study was designed as test-retest. The setting was the general rehabilitation centre. There were 51 patients over 18 years of age, suffering

  9. Epidemiological study of 183 patients with spontaneous rupture of cerebral aneurysm

    International Nuclear Information System (INIS)

    Antonova, D.; Tasheva, E.

    2015-01-01

    Cerebral vessels aneurysms represent a significant part of the cerebral vessels pathology. There is no extensive study on that in Bulgaria. We present a study of 183 patients with spontaneous rupture of cerebral aneurysm, diagnosed and treated in UMHATEM ‘Pirogov’, Sofia. We used clinical methods - data from subject history, analysis of the accompanying documentation, subject medical chart; imaging-diagnostics methods - CT, DSA and MRI; and statistical methods. A total of 183 patients with ruptured intracranial aneurysms were studied. 65% were females and 35% were men.The ration female/male is 1.86, The mean age of all patients is 53.1 ±10.1 years. The highest incidence of ruptured aneurysms is seen in the age group 50 to 59 years. Aneurysms of a. cerebri media and a. communicants anterior are the most frequent (63.4% in total); while the lest are those of a basilaris (4.9%). 88.5% of the aneurysms in the studied group are small, 9.8% are large and 1.6% are giant. Intracranial hematomas are seen in 13.1% of the patients with ruptured aneurysms. Most frequently hematomas are connected with a. cerebri media and a.communicants anterior (87.5% in total). Patients with multiple aneurysms are 11.5% in total, 85.7% of them with an aneurysm of a.cerebri media. The incidence of ruptured cerebral aneurysms is higher amongst female. Frequency in the fifth decade of life is the highest. Most often seen are the aneurysms of a. cerebri media and a. communicants anterior, and the least - those of a. basilaris. Intracranial hematomas most frequently are associated with ruptures of a. cerebri media and a. communicants anterior, in patients with multiple aneurysms the highest is the frequency of aneurysms of a. cerebri media. (authors)

  10. Rupture, waves and earthquakes.

    Science.gov (United States)

    Uenishi, Koji

    2017-01-01

    Normally, an earthquake is considered as a phenomenon of wave energy radiation by rupture (fracture) of solid Earth. However, the physics of dynamic process around seismic sources, which may play a crucial role in the occurrence of earthquakes and generation of strong waves, has not been fully understood yet. Instead, much of former investigation in seismology evaluated earthquake characteristics in terms of kinematics that does not directly treat such dynamic aspects and usually excludes the influence of high-frequency wave components over 1 Hz. There are countless valuable research outcomes obtained through this kinematics-based approach, but "extraordinary" phenomena that are difficult to be explained by this conventional description have been found, for instance, on the occasion of the 1995 Hyogo-ken Nanbu, Japan, earthquake, and more detailed study on rupture and wave dynamics, namely, possible mechanical characteristics of (1) rupture development around seismic sources, (2) earthquake-induced structural failures and (3) wave interaction that connects rupture (1) and failures (2), would be indispensable.

  11. The diagnostic value of the lactate level in the vaginal fluid for determining the premature rupture of membranes

    International Nuclear Information System (INIS)

    Ahmadi, M.; Rafaei, F.; Nazari, N.

    2013-01-01

    Objectives:To determine the diagnostic value of the lactate concentration in vaginal secretions in determining the premature rupture of membranes. Subjects and Methods:One hundred 100 pregnant women with single pregnancy of gestational age 20--41 weeks were divided to two groups of 50 each. One group comprised of women with premature rupture of membranes, and the other (control group) of women with intact membranes. To verify the premature rupture of membranes in both groups, the speculum, fern, and nitrazine tests were done. Lactate Pro manual instrument was used to measure the lactate levels in vaginal fluid via enzymatic staining which was displayed on the instrument's liquid crystal display after 60 seconds. Descriptive analytic statistics and SPSS 17 software were used to analyze the data. Results The lactate concentration of 4.6 mM in the vaginal fluid was diagnostic for premature rupture of membranes. It had a sensitivity of 96%, specificity of 98.8%, accuracy of 97%, positive predictive value of 97.9%, and negative predictive value of 96%. Conclusions:Testing lactate levels in the vaginal fluid is an easy, rapid and reliable method for the diagnosis of premature rupture of membranes in pregnancy. (author)

  12. A New Approach for Reliability Life Prediction of Rail Vehicle Axle by Considering Vibration Measurement

    Directory of Open Access Journals (Sweden)

    Meral Bayraktar

    2014-01-01

    Full Text Available The effect of vibration on the axle has been considered. Vibration measurements at different speeds have been performed on the axle of a running rail vehicle to figure out displacement, acceleration, time, and frequency response. Based on the experimental works, equivalent stress has been used to find out life of the axles for 90% and 10% reliability. Calculated life values of the rail vehicle axle have been compared with the real life data and it is found that the life of a vehicle axle taking into account the vibration effects is in good agreement with the real life of the axle.

  13. Slow rupture of frictional interfaces

    OpenAIRE

    Sinai, Yohai Bar; Brener, Efim A.; Bouchbinder, Eran

    2011-01-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not comple...

  14. Rupture of a pacemaker lead during the course of infective endocarditis.

    Science.gov (United States)

    Akgüllü, Çağdaş; Eryılmaz, Ufuk; Kurtoğlu, Tünay; Özpelit, Ebru

    2013-01-01

    A 23-year-old male who had a VDDR pacemaker implanted seven years ago due to sick sinus syndrome and recurrent syncope episodes was admitted with symptoms of dyspnea, fever, and tachycardia, which were present for a few days. He was suspected to be suffering from pneumonia and underwent computed tomography scanning of the thorax, which revealed widespread infiltration in the lung parenchyma and pulmonary emboli. Transthoracic echocardiography revealed an extremely mobile echogenic structure in the right atrium, which was determined to be the free portion of a ruptured pacemaker lead. There was an overlying thrombus and/or vegetation-like organized soft tissue within the right ventricle around the lead component. In this article, the rupture of a permanent pacemaker lead, which complicated the course of infective endocarditis associated with pulmonary embolism and pneumonia is reported. We hypothesize that the underlying mechanism for the rupture is soft tissue entrapment within the right ventricle. Unfortunately, this rare and life-threatening situation led to the death of our patient after the surgical removal of the device and its components.

  15. Validity and reliability of the novel thyroid-specific quality of life questionnaire, ThyPRO

    DEFF Research Database (Denmark)

    Watt, Torquil; Hegedus, Laszlo; Grønvold, Mogens

    2010-01-01

    Appropriate scale validity and internal consistency reliability have recently been documented for the new thyroid-specific quality of life (QoL) patient-reported outcome (PRO) measure for benign thyroid disorders, the ThyPRO. However, before clinical use, clinical validity and test...

  16. Radioactivity transport following steam generator tube rupture

    International Nuclear Information System (INIS)

    Hopenfeld, J.

    1985-03-01

    A review of the capabilities of the CITADEL computer code as well as plant experience to project radioactivity releases following a steam generator tube rupture in PWR's shows that certain experimental data are needed for reliable off-site dose predictions. This article defines five parameters which are the key for such predictions and discusses the functional dependence of these parameters on various operational variables. The above parameters can be used in conjunction with CITADEL or they can be inserted in the appropriate equations which then conveniently can be programmed as a subroutine in thermal-hydraulic system codes. A joint Westinghouse, Electric Power Research Institute and Nuclear Regulatory Commission Program aimed at obtaining the five parameters empirically is described

  17. Reliable tool life measurements in turning - an application to cutting fluid efficiency evaluation

    DEFF Research Database (Denmark)

    Axinte, Dragos A.; Belluco, Walter; De Chiffre, Leonardo

    2001-01-01

    The paper proposes a method to obtain reliable measurements of tool life in turning, discussing some aspects related to experimental procedure and measurement accuracy. The method (i) allows and experimental determination of the extended Taylor's equation, with a limited set of experiments and (ii......) provides efficiency evaluation. Six cutting oils, five of which formulated from vegetable basestock, were evaluated in turning. Experiments were run in a range of cutting parameters. according to a 2, 3-1 factorial design, machining AISI 316L stainless steel with coated carbide tools. Tool life...

  18. Material Parameters for Creep Rupture of Austenitic Stainless Steel Foils

    Science.gov (United States)

    Osman, H.; Borhana, A.; Tamin, M. N.

    2014-08-01

    Creep rupture properties of austenitic stainless steel foil, 347SS, used in compact recuperators have been evaluated at 700 °C in the stress range of 54-221 MPa to establish the baseline behavior for its extended use. Creep curves of the foil show that the primary creep stage is brief and creep life is dominated by tertiary creep deformation with rupture lives in the range of 10-2000 h. Results are compared with properties of bulk specimens tested at 98 and 162 MPa. Thin foil 347SS specimens were found to have higher creep rates and higher rupture ductility than their bulk specimen counterparts. Power law relationship was obtained between the minimum creep rate and the applied stress with stress exponent value, n = 5.7. The value of the stress exponent is indicative of the rate-controlling deformation mechanism associated with dislocation creep. Nucleation of voids mainly occurred at second-phase particles (chromium-rich M23C6 carbides) that are present in the metal matrix by decohesion of the particle-matrix interface. The improvement in strength is attributed to the precipitation of fine niobium carbides in the matrix that act as obstacles to the movement of dislocations.

  19. Rupture of an abdominal aortic aneurysm in a young man with Marfan Syndrome

    DEFF Research Database (Denmark)

    Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren

    2018-01-01

    Abdominal aortic aneurysms are very rare in Marfan syndrome. We present a case with a young non-smoking and normotensive male with Marfan syndrome, who developed an infrarenal abdominal aortic aneurysm that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock...

  20. Aortic ruptures in seat belt wearers.

    Science.gov (United States)

    Arajärvi, E; Santavirta, S; Tolonen, J

    1989-09-01

    Several investigations have indicated that rupture of the thoracic aorta is one of the leading causes of immediate death in victims of road traffic accidents. In Finland in 1983, 92% of front-seat passengers were seat belt wearers on highways and 82% in build-up areas. The mechanisms of rupture of the aorta have been intensively investigated, but the relationship between seat belt wearing and injury mechanisms leading to aortic rupture is still largely unknown. This study comprises 4169 fatally injured victims investigated by the Boards of Traffic Accident Investigation of Insurance Companies during the period 1972 to 1985. Chest injuries were recorded as the main cause of death in 1121 (26.9%) victims, 207 (5.0%) of those victims having worn a seat belt. Aortic ruptures were found at autopsy in 98 victims and the exact information of the location of the aortic tears was available in 68. For a control group, we analyzed 72 randomly chosen unbelted victims who had a fatal aortic rupture in similar accidents. The location of the aortic rupture in unbelted victims was more often in the ascending aorta, especially in drivers, whereas in seat belt wearers the distal descending aorta was statistically more often ruptured, especially in right-front passengers (p less than 0.05). The steering wheel predominated statistically as the part of the car estimated to have caused the injury in unbelted victims (37/72), and some interior part of the car was the most common cause of fatal thoracic impacts in seat belt wearers (48/68) (p less than 0.001). The mechanism of rupture of the aorta in the classic site just distal to the subclavian artery seems to be rapid deceleration, although complex body movements are also responsible in side impact collisions. The main mechanism leading to rupture of the ascending aorta seems to be severe blow to the bony thorax. This also often causes associated thoracic injuries, such as heart rupture and sternal fracture. Injuries in the ascending

  1. Reliability Based Optimal Design of Vertical Breakwaters Modelled as a Series System Failure

    DEFF Research Database (Denmark)

    Christiani, E.; Burcharth, H. F.; Sørensen, John Dalsgaard

    1996-01-01

    Reliability based design of monolithic vertical breakwaters is considered. Probabilistic models of important failure modes such as sliding and rupture failure in the rubble mound and the subsoil are described. Characterisation of the relevant stochastic parameters are presented, and relevant design...... variables are identified and an optimal system reliability formulation is presented. An illustrative example is given....

  2. Validity and reliability of the Portuguese-Brazilian version of the Quality of Life in Epilepsy Inventory-89.

    Science.gov (United States)

    Azevedo, Auro Mauro; Alonso, Neide Barreira; Vidal-Dourado, Marcos; Noffs, Maria Helena da Silva; Pascalicchio, Tatiana Frascarelli; Caboclo, Luís Otávio Sales Ferreira; Ciconelli, Rozana Mesquita; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2009-03-01

    The purpose of this article was to report the translation of the Quality of Life in Epilepsy Inventory-89 (QOLIE-89) into a Portuguese-Brazilian version and evaluate its reliability and validity. This study involved 105 outpatients: 54 patients with refractory temporal lobe epilepsy (TLE) with mesial temporal sclerosis (MTS) and 51 with juvenile myoclonic epilepsy (JME). Reliability and test-retest reliability were assessed. Relationships between QOLIE-89 domains and other questionnaires (Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, Neuropsychological Evaluation), and external measures such as demographic and clinical variables were analyzed to examine construct validity. Internal consistency (Cronbach's alpha=0.73-0.92) and test-retest reliability (intraclass correlation coefficient=0.60-0.84) for individual domains were acceptable. For construct validity, we verified high correlations between the QOLIE-89 and the Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, and Neuropsychological Evaluation. For clinical characteristics, the patients with juvenile myoclonic epilepsy had better quality-of-life scores on 11 of 17 QOLIE-89 subscales compared with patients with temporal lobe epilepsy (P<0.05). These results support the reliability and validity of the Portuguese-Brazilian translation of QOLIE-89.

  3. Ruptured cornual pregnancy

    International Nuclear Information System (INIS)

    Hussain, M.; Yasmeen, H.; Noorani, K.

    2003-01-01

    A case of ruptured cornual pregnancy is presented here. The patient presented with history of 30 weeks gestational amenorrhoea and pain in the lower abdomen and epigastrium for the last seven days. Ultrasound revealed a 29 weeks abdominal pregnancy with blood in the pelvic cavity. On laparotomy; there was a ruptured right cornual pregnancy, treated cornual resection and uterine repair. An alive male baby of one kg weight was delivered from the resected cornua of the uterus. (author)

  4. Evaluation of design, leak monitoring, dnd NDEA strategies to assure PBMR Helium pressure boundary reliability - HTR2008-58037

    International Nuclear Information System (INIS)

    Fleming, K. N.; Smit, K.

    2008-01-01

    This paper discusses the reliability and integrity management (RIM) strategies that have been applied in the design of the PBMR passive metallic components for the helium pressure boundary (HPB) to meet reliability targets and to evaluate what combination of strategies are needed to meet the targets. The strategies considered include deterministic design strategies to reduce or eliminate the potential for specific damage mechanisms, use of an on-line leak monitoring system and associated design provisions that provide a high degree of leak detection reliability, and periodic nondestructive examinations combined with repair and replacement strategies to reduce the probability that degradation would lead to pipe ruptures. The PBMR RIM program for passive metallic piping components uses a leak-before-break philosophy. A Markov model developed for use in LWR risk-informed in-service inspection evaluations was applied to investigate the impact of alternative RIM strategies and plant age assumptions on the pipe rupture frequencies as a function of rupture size. Some key results of this investigation are presented in this paper. (authors)

  5. Validity and reliability of the novel thyroid-specific quality of life questionnaire, ThyPRO

    DEFF Research Database (Denmark)

    Watt, Torquil; Hegedüs, Laszlo; Groenvold, Mogens

    2010-01-01

    Background Appropriate scale validity and internal consistency reliability have recently been documented for the new thyroid-specific quality of life (QoL) patient-reported outcome (PRO) measure for benign thyroid disorders, the ThyPRO. However, before clinical use, clinical validity and test......-retest reliability should be evaluated. Aim To investigate clinical ('known-groups') validity and test-retest reliability of the Danish version of the ThyPRO. Methods For each of the 13 ThyPRO scales, we defined groups expected to have high versus low scores ('known-groups'). The clinical validity (known......-groups validity) was evaluated by whether the ThyPRO scales could detect expected differences in a cross-sectional study of 907 thyroid patients. Test-retest reliability was evaluated by intra-class correlations of two responses to the ThyPRO 2 weeks apart in a subsample of 87 stable patients. Results On all 13...

  6. Spontaneous Rupture of the Bicornuate Uterus During 12th Week of Pregnancy

    Directory of Open Access Journals (Sweden)

    Tayfun Özçakır

    2011-12-01

    uterus bicornis was diagnosed. The fetus and placenta were found in the abdominal cavity. Spontaneous rupture of the pregnant uterus generally occurs in congenitally malformed uteri like unicornuate or bicornuate uterus with or without rudimentary communicating-noncommunicating horn. It can be life threatening and should be diagnosed and treated immediately.

  7. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Finite element reliability analysis of fatigue life

    International Nuclear Information System (INIS)

    Harkness, H.H.; Belytschko, T.; Liu, W.K.

    1992-01-01

    Fatigue reliability is addressed by the first-order reliability method combined with a finite element method. Two-dimensional finite element models of components with cracks in mode I are considered with crack growth treated by the Paris law. Probability density functions of the variables affecting fatigue are proposed to reflect a setting where nondestructive evaluation is used, and the Rosenblatt transformation is employed to treat non-Gaussian random variables. Comparisons of the first-order reliability results and Monte Carlo simulations suggest that the accuracy of the first-order reliability method is quite good in this setting. Results show that the upper portion of the initial crack length probability density function is crucial to reliability, which suggests that if nondestructive evaluation is used, the probability of detection curve plays a key role in reliability. (orig.)

  9. Rupture disc opening property for using pipe rupture test in JAERI

    International Nuclear Information System (INIS)

    Kato, Rokuro

    1983-03-01

    In the Mechanical Strength and Structure Lab of JAERI there are being performed pipe break tests which are a postulated instantaneous guillotine break of the primary coolant piping in nuclear power plants. The test being performed are pipe whip tests and jet discharging tests. The bursting of the rupture disc is initiated by an electrical arc and is concluded by the internal pressure. Because the time characteristics during the opening of the rupture disc affects the dynamic thrust force of the pipe, it is necessary to measure these time characteristics. However, it is difficult to measure the conditions during this continuous opening because at the same time of the opening the high temperature and high pressure water is flashing. Therefore, the rupture disc opening was postulated on the measuring of the effective opening characteristics with electric contraction terminals which were attached to the inner surface of the test pipe downstream of the rupture disc and were extended toward the pipe centerline in a ring whose area is about 60 % of the area of the pipe flow sectional area. The measurement voltage was recorded when the data recorder was started in sequence with the electrical arc release from a trigger signal. As a result, it is evident that under high temperature and high pressure water the effective opening time is delayed by a few milliseconds. (author)

  10. Splenic rupture masquerading ruptured ectopic pregnancy | Kigbu ...

    African Journals Online (AJOL)

    The classical triad of presentation of delayed menses, irregular vaginal bleeding and abdominal pain may not be encountered at all! Overwhelming features of abdominal pain, amenorrhea, pallor, abdominal tenderness, shifting dullness with positive pregnancy test gave a clinical diagnosis of ruptured ectopic pregnancy.

  11. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  12. A Rare Case of Second Trimester Uterine Rupture in Unscarred Uterus

    Directory of Open Access Journals (Sweden)

    Poonam Kashyap

    2017-11-01

    Full Text Available Second trimester uterine rupture is rare and presents with life threatening emergency. Few cases have been reported in literature. Most of the cases which have been reported are with the use of labor-induction agents in late termination of pregnancy. Others are involving any surgical procedures in placenta percreta or scarred uterus. The main contributory factors were scarred uterus and abnormal placentation. In this study, uterine rupture had occurred in unscarred uterus in non-laboring women in second trimester without any intervention which is very rare to found. The lack of index of high suspicion diverts attention to search for other non-gynecological causes. Our aim is to create awareness through this case study to avoid delay in diagnosis and timely management of such cases.

  13. System reliability of corroding pipelines

    International Nuclear Information System (INIS)

    Zhou Wenxing

    2010-01-01

    A methodology is presented in this paper to evaluate the time-dependent system reliability of a pipeline segment that contains multiple active corrosion defects and is subjected to stochastic internal pressure loading. The pipeline segment is modeled as a series system with three distinctive failure modes due to corrosion, namely small leak, large leak and rupture. The internal pressure is characterized as a simple discrete stochastic process that consists of a sequence of independent and identically distributed random variables each acting over a period of one year. The magnitude of a given sequence follows the annual maximum pressure distribution. The methodology is illustrated through a hypothetical example. Furthermore, the impact of the spatial variability of the pressure loading and pipe resistances associated with different defects on the system reliability is investigated. The analysis results suggest that the spatial variability of pipe properties has a negligible impact on the system reliability. On the other hand, the spatial variability of the internal pressure, initial defect sizes and defect growth rates can have a significant impact on the system reliability.

  14. Reliability of the Music in Everyday Life (MEL) Scale: A Parent-Report Assessment for Children on the Autism Spectrum.

    Science.gov (United States)

    Gottfried, Tali; Thompson, Grace; Elefant, Cochavit; Gold, Christian

    2018-06-07

    For young children on the autism spectrum, the inclusion of shared parent-child music activities in everyday life may provide additional opportunities for social interactions in the home. However, no psychometrically validated assessment exists to measure the extent of shared music activity within family or community contexts. This study aimed to develop and test the reliability of a self-report assessment to measure the use of Music in Everyday Life (MEL) by parents with young children on the autism spectrum. A total of 45 mothers of children with autism aged between 4 and 7 years completed the MEL questionnaire. Internal consistency and item-total correlation were examined. Analysis confirmed the reliability of two predetermined subscales: Music in Everyday Life-Joint Activities using Music (MEL-JAM) and Music in Everyday Life-Routine Activities using Music (MEL-RAM). Internal consistency (Cronbach's alpha 0.63 and 0.75) and positive item-total correlation (Pearson's r between .23 to .62 for MEL-JAM and between .30 to .67 for MEL-RAM) were demonstrated. The reliability of the MEL assessment to measure the use of music in everyday life by parents with their children with autism was confirmed, filling an important gap in the availability of assessment tools.

  15. Long-term results after repair of ruptured and non-ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kuzmanović Ilija B.

    2004-01-01

    Full Text Available INTRODUCTION Abdominal aortic aneurysm can be repaired by elective procedure while asymptomatic, or immediately when it is complicated - mostly due to rupture. Treating abdominal aneurysm electively, before it becomes urgent, has medical and economical reason. Today, the first month mortality after elective operations of the abdominal aorta aneurysm is less than 3%; on the other hand, significant mortality (25%-70% has been recorded in patients operated immediately because of rupture of the abdominal aneurysm. In addition, the costs of elective surgical treatment are significantly lower. OBJECTIVE The objective of this study is to compare long-term survival of patients that underwent elective or immediate repair of abdominal aortic aneurysm (due to rupture, and to find out the factors influencing the long-term survival of these patients. MATERIAL AND METHODS Through retrospective review of prospectively collected data of the Institute for Cardiovascular Diseases of Clinical Center of Serbia, Belgrade, 56 patients that had elective surgery and 35 patients that underwent urgent operation due to rupture of abdominal aneurysm were followed up. Only the patients that survived 30 postoperative days were included in this review, and were followed up (ranging from 2 to 126 months. Electively operated patients were followed during 58.82 months on the average (range 7 to 122, and urgently operated were followed over 52.26 months (range 2 to 126. There was no significant difference of the length of postoperative follow-up between these two groups. RESULTS During this period, out of electively operated and immediately operated patients, 27 and 22 cases died, respectively. There was no significant difference (p>0,05a of long-term survival between these two groups. Obesity and early postoperative complications significantly decreased long-term survival of both electively and immediately operated patients. Graft infection, ventral hernia, aneurysm of

  16. Forecasting magma-chamber rupture at Santorini volcano, Greece.

    Science.gov (United States)

    Browning, John; Drymoni, Kyriaki; Gudmundsson, Agust

    2015-10-28

    How much magma needs to be added to a shallow magma chamber to cause rupture, dyke injection, and a potential eruption? Models that yield reliable answers to this question are needed in order to facilitate eruption forecasting. Development of a long-lived shallow magma chamber requires periodic influx of magmas from a parental body at depth. This redistribution process does not necessarily cause an eruption but produces a net volume change that can be measured geodetically by inversion techniques. Using continuum-mechanics and fracture-mechanics principles, we calculate the amount of magma contained at shallow depth beneath Santorini volcano, Greece. We demonstrate through structural analysis of dykes exposed within the Santorini caldera, previously published data on the volume of recent eruptions, and geodetic measurements of the 2011-2012 unrest period, that the measured 0.02% increase in volume of Santorini's shallow magma chamber was associated with magmatic excess pressure increase of around 1.1 MPa. This excess pressure was high enough to bring the chamber roof close to rupture and dyke injection. For volcanoes with known typical extrusion and intrusion (dyke) volumes, the new methodology presented here makes it possible to forecast the conditions for magma-chamber failure and dyke injection at any geodetically well-monitored volcano.

  17. Creep-Fatigue Life Design with Various Stress and Temperature Conditions on the Basis of Lethargy Coefficient

    International Nuclear Information System (INIS)

    Park, Jung Eun; Yang, Sung Mo; Han, Jae Hee; Yu, Hyo Sun

    2011-01-01

    High temperature and stress are encounted in power plants and vehicle engines. Therefore, determination of the creep-fatigue life of a material is necessary prior to fabricating equipment. In this study, life design was determined on the basis of the lethargy coefficient for different temperatures, stress and rupture times. SP-Creep test data was compared with computed data. The SP-Creep test was performed to obtain the rupture time for X20CrMoV121 steel. The integration life equation was considered for three cases with various load, temperature and load-temperature. First, the lethargy coefficient was calculated by using the obtained rupture stress and the rupture time that were determined by carrying out the SP-Creep test. Next, life was predicted on the basis of the temperature condition. Finally, it was observed that life decreases considerably due to the coupling effect that results when fatigue and creep occur simultaneously

  18. Determination of Remaining Useful Life of Gas Turbine Blade

    Directory of Open Access Journals (Sweden)

    Meor Said Mior Azman

    2016-01-01

    Full Text Available The aim of this research is to determine the remaining useful life of gas turbine blade, using service-exposed turbine blades. This task is performed using Stress Rupture Test (SRT under accelerated test conditions where the applied stresses to the specimen is between 400 MPa to 600 MPa and the test temperature is 850°C. The study will focus on the creep behaviour of the 52000 hours service-exposed blades, complemented with creep-rupture modelling using JMatPro software and microstructure examination using optical microscope. The test specimens, made up of Ni-based superalloy of the first stage turbine blades, are machined based on International Standard (ISO 24. The results from the SRT will be analyzed using these two main equations – Larson-Miller Parameter and Life Fraction Rule. Based on the results of the remaining useful life analysis, the 52000h service-exposed blade has the condition to operate in the range of another 4751 hr to 18362 hr. The microstructure examinations shows traces of carbide precipitation that deteriorate the grain boundaries that occurs during creep process. Creep-rupture life modelling using JMatPro software has shown good agreement with the accelerated creep rupture test with minimal error.

  19. A Study on the Storage Reliability of LSINS Based on Step-stress Accelerated Life Test

    Directory of Open Access Journals (Sweden)

    Teng Fei

    2015-01-01

    Full Text Available Based on the step-stress accelerated life test and the laser strap-down inertial navigation system, this paper studies the accelerated life model and the test method, provides the likelihood function, the likelihood equation and the two-order derivative when the stress level is k, evaluates the effectiveness of the method with the simulation test model established by MATLAB, applies the research findings in the storage reliability study of the XX laser strap-down inertial navigation system, and puts forward an effective evaluation method of the storage life of the inertial navigation system.

  20. [Simultaneous Traumatic Rupture of Patellar Ligament and Contralateral Rupture of Quadriceps Femoris Muscle].

    Science.gov (United States)

    Hladký, V; Havlas, V

    2017-01-01

    Our paper presents a unique case of a 64-year-old patient after a fall, treated with oral antidiabetic drugs for type II diabetes mellitus. Following a series of examinations, a bilateral injury was diagnosed - patellar ligament tear on the right side and rupture of quadriceps femoris muscle on the left side. It is a rare injury, complicated by simultaneous involvement of both knee joints. The used therapy consisted of a bilateral surgery followed by gradual verticalisation, first with the support of a walking frame and later with the use of forearm crutches. During the final examination, the patient demonstrated full flexion at both knees, while an extension deficit of approx. 5 degrees was still present on the left side. The right knee X-ray showed a proper position of the patella after the removal of temporary tension band wire. Although the clinical results of operative treatment of both the patellar ligament rupture and rupture of quadriceps femoris muscle are in most cases good, early operative treatment, proper technique and post-operative rehabilitation are a prerequisite for success. Key words: knee injuries, patellar ligament, quadriceps muscle, rupture.

  1. Effect of Post-Weld Heat Treatment on Creep Rupture Properties of Grade 91 Steel Heavy Section Welds

    Energy Technology Data Exchange (ETDEWEB)

    Li, Leijun

    2012-11-02

    This project will conduct a systematic metallurgical study on the effect of post-weld heat treatment (PWHT) on the creep rupture properties of P91 heavy section welds. The objective is to develop a technical guide for selecting PWHT parameters, and to predict expected creep-rupture life based on the selection of heat treatment parameters. The project consists of four interdependent tasks: Experimentally and numerically characterize the temperature fields of typical post-weld heat treatment procedures for various weld and joint configurations to be used in Gen IV systems. Characterize the microstructure of various regions, including the weld fusion zone, coarse-grain heat-affected zone, and fine-grain heat affected zone, in the welds that underwent the various welding and PWHT thermal histories. Conduct creep and creep-rupture testing of coupons extracted from actual and physically simulated welds. Establish the relationship among PWHT parameters, thermal histories, microstructure, creep, and creep-rupture properties.

  2. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  3. Traumatic rupture of an intracranial dermoid cyst

    Directory of Open Access Journals (Sweden)

    Raksha Ramlakhan, BMedSc, MBBCh

    2015-01-01

    Full Text Available Intracranial dermoid cysts are congenital tumors of ectodermal origin. Rupture of these cysts can occur spontaneously, but rupture in association with trauma is reported infrequently. The diagnosis of rupture is made by the presence of lipid (cholesterol droplets in the subarachnoid spaces and ventricles. Nonenhanced CT of the head demonstrates multiple foci of low attenuation that correspond with hyperintense signal on T1-weighted MRI. We present a case of an adult patient with rupture of an intracranial dermoid cyst, precipitated by minor trauma.

  4. Arthroscintigraphy in suspected rotator cuff rupture

    International Nuclear Information System (INIS)

    Gratz, S.; Behr, T.; Becker, W.; Koester, G.; Vosshenrich, R.; Grabbe, E.

    1998-01-01

    Aim: In order to evaluate the diagnostic efficiency of arthroscintigraphy in suspected rotator cuff ruptures this new imaging procedure was performed 20 times in 17 patients with clinical signs of a rotator cuff lesion. The scintigraphic results were compared with sonography (n=20), contrast arthrography (n=20) and arthroscopy (n=10) of the shoulder joint. Methods: After performing a standard bone scintigraphy with intravenous application of 300 MBq 99m-Tc-methylene diphosphonate (MDP) for landmarking of the shoulder region arthroscintigraphy was performed after an intraarticular injection of 99m-Tc microcolloid (ALBU-RES 400 μCi/5 ml). The application was performed either in direct combination with contrast arthrography (n=10) or ultrasound conducted mixed with a local anesthetic (n=10). Findings at arthroscopical surgery (n=10) were used as the gold standard. Results: In case of complete rotator cuff rupture (n=5), arthroscintigraphy and radiographic arthrography were identical in 5/5. In one patient with advanced degenerative alterations of the shoulder joint radiographic arthrography incorrectly showed a complete rupture which was not seen by arthroscintigraphy and endoscopy. In 3 patients with incomplete rupture, 2/3 results were consistant. A difference was seen in one patient with a rotator cuff, that has been already revised in the past and that suffered of capsulitis and calcification. Conclusion: Arthroscinitgraphy is a sensitive technique for detection of rotator cuff ruptures. Because of the lower viscosity of the active compound, small ruptures can be easily detected, offering additional value over radiographic arthrography and ultrasound, especially for evaluation of incomplete cuff ruptures. (orig.) [de

  5. [Development and reliability evaluation of an instrument to measure health-related quality of life in independent elderly].

    Science.gov (United States)

    Lima, Maria José Barbosa de; Portela, Margareth Crisóstomo

    2010-08-01

    This study presents an instrument, the health-related quality of life (HRQOL) profile for independent elderly, to measure the health-related quality of life of the functionally independent elderly assisted in the outpatient setting, based on the adaptation of four validated scales: Short-Form Health Survey (SF-36), Duke-UNC Health Profile (DUHP), Sickness Impact Profile (SIP), and Nottingham Health Profile (NHP). The study also evaluates the instrument's reliability based on its use by two different observers with a 15-day interval. The instrument includes five dimensions (health perception, symptoms, physical function, psychological function, and social function) and 45 items. Reliability evaluation of the QUASI instrument was based on interviews with 142 elderly outpatients in the city of Rio de Janeiro, Brazil. Prevalence-adjusted kappa statistic was used to assess all 45 items. Correlation was also calculated between overall scores and scores on individual dimensions. In the reliability evaluation, 39 of the 45 items showed prevalence-adjusted kappa greater than 0.60.

  6. Neck curve polynomials in neck rupture model

    International Nuclear Information System (INIS)

    Kurniadi, Rizal; Perkasa, Yudha S.; Waris, Abdul

    2012-01-01

    The Neck Rupture Model is a model that explains the scission process which has smallest radius in liquid drop at certain position. Old fashion of rupture position is determined randomly so that has been called as Random Neck Rupture Model (RNRM). The neck curve polynomials have been employed in the Neck Rupture Model for calculation the fission yield of neutron induced fission reaction of 280 X 90 with changing of order of polynomials as well as temperature. The neck curve polynomials approximation shows the important effects in shaping of fission yield curve.

  7. The stochastic finite element methods with applications in geotechnics and rupture mechanics

    International Nuclear Information System (INIS)

    Baldeweck, Herve

    1999-01-01

    After having presented and classified the various stochastic finite elements methods, notably by distinguishing reliability methods (first order and second order reliability methods, response surfaces, Monte Carlo) and sensitivity methods (Monte Carlo, spectral development, perturbation, weighted integrals), the author of this research thesis presents basic tools needed for different theoretical developments: hazard representation and method of moments. He also presents the problem which is used all along this work to compare and assess the different sensitivity methods. Then, he reports the theoretical development of these sensitivity methods: the Monte Carlo method, the spectral development method, the perturbation method, and the quadrature method. This last one is a new one aimed at the assessment of statistical moments. The author highlights the relationships between reliability and sensitivity methods. In the third part, several applications and calculations are reported. Applications are in geotechnics (soil-structure interaction, calculation of soil stiffness, application in the field of geo-materials with the calculation of an underground gallery), and in rupture mechanics (international benchmark on the reliability of a nuclear reactor, non linear calculation of a cracked straight pipe, reliability calculation of a cracked plate with a Young modulus being a random field) [fr

  8. A reliability based stress-life evaluation of aluminium-graphite particulate composites

    International Nuclear Information System (INIS)

    Achutha, M.V.; Sridhara, B.K.; Abdul Budan, D.

    2008-01-01

    Fatigue tests were conducted on sand cast aluminium-graphite composite specimens on Rotating Beam Fatigue Testing Machine with three different stress levels. Aluminium-graphite (LM 25-5% graphite) composite was processed by closed mould sand casting method. Three-stress level fatigue test program was planned for carrying out fatigue experiments. Three different stress levels selected for fatigue experiments were a fraction of ultimate tensile strength. Statistical design of fatigue experiments was carried out to determine the sample size at each stress level. Experimental results are presented in the form of stress-life (S-N) curves and reliability-stress-life (R-S-N) curves, which are helpful for designers. The S-N curve of the aluminium-graphite composite was compared with its matrix alloy LM 25. Comparison revealed that the fatigue behaviour of the aluminium-graphite composite is superior to that of the matrix alloy

  9. Comparison between smaller ruptured intracranial aneurysm and larger un-ruptured intracranial aneurysm: gene expression profile analysis.

    Science.gov (United States)

    Li, Hao; Li, Haowen; Yue, Haiyan; Wang, Wen; Yu, Lanbing; ShuoWang; Cao, Yong; Zhao, Jizong

    2017-07-01

    As it grows in size, an intracranial aneurysm (IA) is prone to rupture. In this study, we compared two extreme groups of IAs, ruptured IAs (RIAs) smaller than 10 mm and un-ruptured IAs (UIAs) larger than 10 mm, to investigate the genes involved in the facilitation and prevention of IA rupture. The aneurismal walls of 6 smaller saccular RIAs (size smaller than 10 mm), 6 larger saccular UIAs (size larger than 10 mm) and 12 paired control arteries were obtained during surgery. The transcription profiles of these samples were studied by microarray analysis. RT-qPCR was used to confirm the expression of the genes of interest. In addition, functional group analysis of the differentially expressed genes was performed. Between smaller RIAs and larger UIAs, 101 genes and 179 genes were significantly over-expressed, respectively. In addition, functional group analysis demonstrated that the up-regulated genes in smaller RIAs mainly participated in the cellular response to metal ions and inorganic substances, while most of the up-regulated genes in larger UIAs were involved in inflammation and extracellular matrix (ECM) organization. Moreover, compared with control arteries, inflammation was up-regulated and muscle-related biological processes were down-regulated in both smaller RIAs and larger UIAs. The genes involved in the cellular response to metal ions and inorganic substances may facilitate the rupture of IAs. In addition, the healing process, involving inflammation and ECM organization, may protect IAs from rupture.

  10. Ruptured gastroepiploic artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Ahmad S. Ashrafi

    Full Text Available Introduction: Gastroepiploic artery aneurysms are extremely rare, with few reported cases in the literature. The risk of rupture however, is high and thus warrants attention. Presentation of case: Here we present a rare case of a women who presented to the emergency department in shock and was found to have a ruptured gastroepiploic artery aneurysm during surgical exploration. Suture ligation of the aneurysm was completed. Discussion: Although rare, gastroepiploic artery aneurysms have up to a 90% rate of rupture and therefore require intervention. A laparoscopic approach has been described however, in cases where rupture has occurred, urgent laparotomy and control of hemorrhage is needed. Conclusion: We describe a rare case of a ruptured gastroepiploic aneurysm that was successfully managed with urgent laparotomy and aneurysmal resection. Keywords: Gastroepiploic, Aneurysm, Hemorrhage, Case report

  11. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de fonctionnement et le

  12. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de

  13. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kral, P. [Nuclear Research Inst. Rez (Switzerland)

    1995-12-31

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.

  14. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kral, P [Nuclear Research Inst. Rez (Switzerland)

    1996-12-31

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.

  15. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    International Nuclear Information System (INIS)

    Kral, P.

    1995-01-01

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal 'MSH Rupture' leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS

  16. Comparing slow and fast rupture in laboratory experiments

    Science.gov (United States)

    Aben, F. M.; Brantut, N.; David, E.; Mitchell, T. M.

    2017-12-01

    During the brittle failure of rock, elastically stored energy is converted into a localized fracture plane and surrounding fracture damage, seismic radiation, and thermal energy. However, the partitioning of energy might vary with the rate of elastic energy release during failure. Here, we present the results of controlled (slow) and dynamic (fast) rupture experiments on dry Lanhélin granite and Westerly granite samples, performed under triaxial stress conditions at confining pressures of 50 and 100 MPa. During the tests, we measured sample shortening, axial load and local strains (with 2 pairs of strain gauges glued directly onto the sample). In addition, acoustic emissions (AEs) and changes in seismic velocities were monitored. The AE rate was used as an indicator to manually control the axial load on the sample to stabilize rupture in the quasi-static failure experiments. For the dynamic rupture experiments a constant strain rate of 10-5 s-1 was applied until sample failure. A third experiment, labeled semi-controlled rupture, involved controlled rupture up to a point where the rupture became unstable and the remaining elastic energy was released dynamically. All experiments were concluded after a macroscopic fracture had developed across the whole sample and frictional sliding commenced. Post-mortem samples were epoxied, cut and polished to reveal the macroscopic fracture and the surrounding damage zone. The samples failed with average rupture velocities varying from 5x10-6 m/s up to >> 0.1 m/s. The analyses of AE locations on the slow ruptures reveal that within Westerly granite samples - with a smaller grain size - fracture planes are disbanded in favor of other planes when a geometrical irregularity is encountered. For the coarser grained Lanhélin granite a single fracture plane is always formed, although irregularities are recognized as well. The semi-controlled experiments show that for both rock types the rupture can become unstable in response to these

  17. Ruptured Spleen

    Science.gov (United States)

    ... be caused by various underlying problems, such as mononucleosis and other infections, liver disease, and blood cancers. ... cause a ruptured spleen. For instance, people with mononucleosis — a viral infection that can cause an enlarged ...

  18. The Toronto outcome measure for craniofacial prosthetics: reliability and validity of a condition-specific quality-of-life instrument.

    Science.gov (United States)

    Anderson, James D; Johnston, Dennis A; Haugh, Gil S; Kiat-Amnuay, Sudarat; Gettleman, Lawrence

    2013-01-01

    The purpose of this study was to refine the Toronto Outcome Measure for Craniofacial Prosthetics (TOMCP), present evidence for its reliability and validity, and use the instrument to explore differences in quality of life between prostheses made with chlorinated polyethylene (CPE) (experimental) and silicone (control). As part of a multicenter prospective controlled randomized double-blind single-crossover clinical trial of the two materials, the TOMCP was administered at the start and end of two 4-month study arms, during which 42 patients wore prostheses made from one material then the other. Reliability was assessed at the crossover. To determine validity of the TOMCP, the Linear Analogue Self-Assessment (LASA-12) and the Short-Form 8 (SF-8) were also administered with the TOMCP. The TOMCP was reduced by removing items that were unreliable, had poorly distributed answers, showed increased internal consistency after their removal, or were too highly correlated with more than one other item. The tests of reliability and validity were then repeated. Finally, the reduced instrument was used to test for differences in quality of life between prostheses made of the two materials. The item reduction tactics pared the 52-item instrument down to 27 items. The correlations of both TOMCP versions with the LASA-12 and the SF-8 were found to be statistically significant, providing evidence of the validity of the TOMCP. The instrument revealed significantly better quality of life with silicone rather than CPE prostheses. Both versions of the TOMCP were found to be reliable and valid. The instrument was able to show differences in quality of life between two materials.

  19. Accuracy and Reliability in the Prediction of End-of-Life Performance of Solar Generators

    Science.gov (United States)

    Rapp, Etienne

    2008-09-01

    The end-of-life power analysis of solar arrays is calculated using a combination of arithmetic and root square sums of loss factors. These loss factors are sometimes linked to degradations, sometimes linked to uncertainties. The uncertainties of the degradations are taken into account considering contractual "worst cases". This paper will put the first stones for a move "metrological" evaluation of the probable performance associated with a standard uncertainty. The turn from silicon to triple junction solar cells induces some changes in the degradation parameters of solar arrays: * The triple junction cells are more sensitive to UV darkening than silicon ones. * The cell voltage is higher and the current is lower. Then the cell strings are shorter, and there are more strings in parallel. This induces some changes in the reliability analyses and risk management. * The failure modes and failure rates of these cells have to be compared and discussed. We try to define improved rules to design solar arrays for end of life performance, for a better knowledge of the margins and a better reliability.

  20. Laparoscopic Treatment of a Rare Right Diaphragmatic Rupture with Small Bowel Herniation after Blunt Thoracic Trauma

    Directory of Open Access Journals (Sweden)

    H. Hoffmann

    2010-01-01

    Full Text Available Blunt traumatic diaphragmatic rupture (BTDR is a life-threatening condition with an incidence from 0,8%–1,6% in blunt trauma, mostly located on the left side. The main prognostic factors are severe side injuries and the delay of diagnosis. We present a rare case of a 68-year-old female, with an isolated right diaphragm rupture. The diagnosis was done with a delay of 4 days by thoracic radiographs, which showed a herniation of small bowel into the right thoracic cavity. A reposition of the small bowel and a closure of the diaphragmatic defect by running suture were carried out laparoscopicly. Although large prospective studies concerning the outcome of laparoscopic approach to right BTDR are still missing, we could show, that laparoscopy can be performed safely in right traumatic diaphragm rupture.

  1. Estimation of residual life of boiler tubes using steamside oxide scale thickness

    International Nuclear Information System (INIS)

    Vikrant, K.S.N.; Ramareddy, G.V.; Pavan, A.H.V.; Singh, Kulvir

    2013-01-01

    In thermal power plants, remaining-life-estimation of boiler tubes is required at regular intervals for a safer and a better functionality of boilers. In this paper, a new method is proposed for the residual life estimation of service exposed boiler tubes using Non-Destructive Ultrasonic Oxide scale thickness measurements, average metal temperature and creep master curve. While steady state conduction heat transfer equations are solved to calculate the average metal temperature, creep master curve is generated from short term stress rupture data of rupture life less than 5000 h on a virgin material. In the present study, the residual life of T22 (2.25Cr-1Mo) service exposed Platen Superheater tube is estimated using two master creep curves, i.e. Larson-Miller Parametric (LMP) method of standard ASME T22 creep data and Wilshire approach of short term stress rupture data of T22. As the residual life is calculated from fundamental conduction heat transfer theory and creep rupture data, the proposed method can be applied for different grades of boiler materials. -- Highlights: ► Residual life is calculated from non-destructive oxide scale thickness, creep master curve and average metal temperature. ► A new method is proposed for calculating residual life using above parameters and from conduction heat transfer principles. ► The method can be applied to different boiler grades for estimating residual life and hence the method is generic

  2. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  3. Reliability and validity of the Malay translated version of diabetes quality of life for youth questionnaire

    Directory of Open Access Journals (Sweden)

    Jamaiyah H

    2013-05-01

    Full Text Available Introduction: Many studies reported poorer quality of life (QoL in youth with diabetes compared to healthy peers. One of the tools used is the Diabetes Quality of Life for Youth (DQoLY questionnaire in English. A validated instrument in Malay is needed to assess the perception of QoL among youth with diabetes in Malaysia. Objective: To translate the modified version, i.e., the DQoLY questionnaire,into Malay and determine its reliability and validity.Methods: Translation and back-translation were used. An expert panel reviewed the translated version for conceptual and content equivalence. The final version was then administered to youths with type 1 diabetes mellitus from the universities and Ministry of Health hospitals between August 2006 and September 2007. Reliability was analysed using Cronbach’s alpha, while validity was confirmed using concurrent validity (HbA1c and self-rated health score.Results: A total of 82 youths with type 1 diabetes (38 males aged 10-18 years were enrolled from eight hospitals. The reliability of overall questionnaire was 0.917, and the reliabilities of the three domains ranged from 0.832 to 0.867. HbA1c was positively correlated with worry (p=0.03. The self-rated health score was found to have significant negative correlation with the “satisfaction” (p=0.013 and “impact” (p=0.007 domains.Conclusion: The Malay translated version of DQoLY questionnaire was reliable and valid to be used among youths with type 2 diabetes in Malaysia.

  4. Spontaneous rupture of adrenal metastasis from hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chae Hun; Kim, Hyun Jin; Park, Soo Youn; Hwang, Seong Su; Choi, Hyun Joo [St. Vincent Hospital, Suwon (Korea, Republic of)

    2007-03-15

    Rupture of adrenal tumor from various primary origins is a rather rare event. We report here on a ruptured adrenal metastasis from hepatocellular carcinoma, and this ruptured metastasis was observed at the time of the initial diagnosis.

  5. Life cycle management for equipments in nuclear plants based on reliability and actual conditions

    International Nuclear Information System (INIS)

    Dalin, Wang; Jingquan, Liu; Peng, Liu

    2010-01-01

    Life cycle management model based on reliability includes two parts: obtaining failure rate function and founding cost-oriented model to solve. It is actually a single objective programming whose optimal solution is the most economical replacement period. Parameters of failure rate function are estimated by Weibull process fitting with the method of maximum likelihood. The objective function of the model is life-cost function where the dependent variable is replacement period T, with the constraints of failure rate or availability. After foundation of LCM model, we solve it to find the optimal replacement period for the equipments. (authors)

  6. Metrics for comparing dynamic earthquake rupture simulations

    Science.gov (United States)

    Barall, Michael; Harris, Ruth A.

    2014-01-01

    Earthquakes are complex events that involve a myriad of interactions among multiple geologic features and processes. One of the tools that is available to assist with their study is computer simulation, particularly dynamic rupture simulation. A dynamic rupture simulation is a numerical model of the physical processes that occur during an earthquake. Starting with the fault geometry, friction constitutive law, initial stress conditions, and assumptions about the condition and response of the near‐fault rocks, a dynamic earthquake rupture simulation calculates the evolution of fault slip and stress over time as part of the elastodynamic numerical solution (Ⓔ see the simulation description in the electronic supplement to this article). The complexity of the computations in a dynamic rupture simulation make it challenging to verify that the computer code is operating as intended, because there are no exact analytic solutions against which these codes’ results can be directly compared. One approach for checking if dynamic rupture computer codes are working satisfactorily is to compare each code’s results with the results of other dynamic rupture codes running the same earthquake simulation benchmark. To perform such a comparison consistently, it is necessary to have quantitative metrics. In this paper, we present a new method for quantitatively comparing the results of dynamic earthquake rupture computer simulation codes.

  7. Hepatic Rupture Induced by Spontaneous Intrahepatic Hematoma

    Directory of Open Access Journals (Sweden)

    Jin-bao Zhou

    2018-01-01

    Full Text Available The etiology of hepatic rupture is usually secondary to trauma, and hepatic rupture induced by spontaneous intrahepatic hematoma is clinically rare. We describe here a 61-year-old female patient who was transferred to our hospital with hepatic rupture induced by spontaneous intrahepatic hematoma. The patient had no history of trauma and had a history of systemic lupus erythematosus for five years, taking a daily dose of 5 mg prednisone for treatment. The patients experienced durative blunt acute right upper abdominal pain one day after satiation, which aggravated in two hours, accompanied by dizziness and sweating. Preoperative diagnosis was rupture of the liver mass. Laparotomy revealed 2500 mL fluid consisting of a mixture of blood and clot in the peritoneal cavity. A 3.5 cm × 2.5 cm rupture was discovered on the hepatic caudate lobe near the vena cava with active arterial bleeding, and a 5  × 6 cm hematoma was reached on the right posterior lobe of the liver. Abdominal computed tomography (CT and laparotomy revealed spontaneous rupture of intrahepatic hematoma with hemorrhagic shock. The patient was successfully managed by suturing the rupture of the hepatic caudate lobe and clearing part of the hematoma. The postoperative course was uneventful, and the patient was discharged after two weeks of hospitalization.

  8. Physical therapy in the conservative treatment for anterior cruciate ligament rupture followed by contralateral rupture: case report

    OpenAIRE

    Almeida, Gabriel Peixoto Leão; Arruda, Gilvan de Oliveira; Marques, Amélia Pasqual

    2014-01-01

    Although the surgical reconstruction be the obvious indication for the anterior cruciate ligament (ACL) lesion, there is no consensus on whether the results of surgery are superior to those obtained with nonsurgical management. The objective of this report was to describe a case of nonsurgical treatment for ACL rupture followed by a contralateral rupture. A 28-year-old female practitioner of muay-thai and handball suffered a non-contact ACL rupture in the left knee, and three months after the...

  9. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  10. The Identity Process in Times of Rupture: Narratives From the Egyptian Revolution

    Directory of Open Access Journals (Sweden)

    Sarah Hassan Awad

    2016-05-01

    Full Text Available This is a longitudinal study of the identity process through times of dramatic social change. Using a narrative psychological approach this research follows the life stories of five Egyptian bloggers as they write their stories on online blogs over the course of the three years following the 2011 revolution, at which time Egypt has witnessed major social and political changes. The aim is to understand the identity process of individuals as they develop and adapt through changing social contexts and how they create alternative social relations as they engage in prefigurative politics. The findings shed light on how ruptures trigger a process of reflexivity, adaptive learning, and sense-making that facilitates coping and the reconstruction of a positive identity after ruptures. It also suggests that the narration of the experience of rupture through storytelling creates a heightened sense of agency in individuals’ ability to create new meanings of their world in spite of the socio-cultural and political constraints. This study presents narratives as an informing methodological resource that connects identity process with social representations and emphasizes the value of storytelling as an integral part of the adaptation process.

  11. An Introduction To Reliability

    International Nuclear Information System (INIS)

    Park, Kyoung Su

    1993-08-01

    This book introduces reliability with definition of reliability, requirement of reliability, system of life cycle and reliability, reliability and failure rate such as summary, reliability characteristic, chance failure, failure rate which changes over time, failure mode, replacement, reliability in engineering design, reliability test over assumption of failure rate, and drawing of reliability data, prediction of system reliability, conservation of system, failure such as summary and failure relay and analysis of system safety.

  12. Use of ICD-10 codes to monitor uterine rupture

    DEFF Research Database (Denmark)

    Thisted, Dorthe L A; Mortensen, Laust Hvas; Hvidman, Lone

    2014-01-01

    OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine the vali......OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine...... uterine ruptures, the sensitivity and specificity of the codes for uterine rupture were 83.8% and 99.1%, respectively. CONCLUSION: During the study period the monitoring of uterine rupture in the MBR was inadequate....

  13. Simultaneous bilateral distal biceps tendon rupture during a preacher curl exercise: a case report.

    Science.gov (United States)

    Rokito, Andrew S; lofin, Ilya

    2008-01-01

    Complete rupture of the distal biceps tendon is a rare injury, the overwhelming majority occurring in the dominant arm of males during the fourth to sixth decades of life. Simultaneous bilateral rupture of the distal biceps tendon is an extremely rare occurrence, with only three cases reported in the literature. This unusual injury occurred in a recreational weightlifter during a preacher curl exercise. In this particular case, a 6-week delay in presentation necessitated a staged procedure in which a primary repair was feasible in one elbow, while reconstruction using allograft tissue was required in the contralateral elbow. Satisfactory results for both elbows were achieved, with return to weightlifting by one year following surgery.

  14. Linguine sign in musculoskeletal imaging: calf silicone implant rupture.

    Science.gov (United States)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E; Walker, Eric A

    2015-08-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition.

  15. Physics of Earthquake Rupture Propagation

    Science.gov (United States)

    Xu, Shiqing; Fukuyama, Eiichi; Sagy, Amir; Doan, Mai-Linh

    2018-05-01

    A comprehensive understanding of earthquake rupture propagation requires the study of not only the sudden release of elastic strain energy during co-seismic slip, but also of other processes that operate at a variety of spatiotemporal scales. For example, the accumulation of the elastic strain energy usually takes decades to hundreds of years, and rupture propagation and termination modify the bulk properties of the surrounding medium that can influence the behavior of future earthquakes. To share recent findings in the multiscale investigation of earthquake rupture propagation, we held a session entitled "Physics of Earthquake Rupture Propagation" during the 2016 American Geophysical Union (AGU) Fall Meeting in San Francisco. The session included 46 poster and 32 oral presentations, reporting observations of natural earthquakes, numerical and experimental simulations of earthquake ruptures, and studies of earthquake fault friction. These presentations and discussions during and after the session suggested a need to document more formally the research findings, particularly new observations and views different from conventional ones, complexities in fault zone properties and loading conditions, the diversity of fault slip modes and their interactions, the evaluation of observational and model uncertainties, and comparison between empirical and physics-based models. Therefore, we organize this Special Issue (SI) of Tectonophysics under the same title as our AGU session, hoping to inspire future investigations. Eighteen articles (marked with "this issue") are included in this SI and grouped into the following six categories.

  16. Acute Pectoralis Major Rupture Captured on Video

    Directory of Open Access Journals (Sweden)

    Alejandro Ordas Bayon

    2016-01-01

    Full Text Available Pectoralis major (PM ruptures are uncommon injuries, although they are becoming more frequent. We report a case of a PM rupture in a young male who presented with axillar pain and absence of the anterior axillary fold after he perceived a snap while lifting 200 kg in the bench press. Diagnosis of PM rupture was suspected clinically and confirmed with imaging studies. The patient was treated surgically, reinserting the tendon to the humerus with suture anchors. One-year follow-up showed excellent results. The patient was recording his training on video, so we can observe in detail the most common mechanism of injury of PM rupture.

  17. Spontaneous Splenic Rupture in Vascular Ehlers-Danlos Syndrome.

    Science.gov (United States)

    Batagini, Nayara Cioffi; Gornik, Heather; Kirksey, Lee

    2015-01-01

    Vascular Ehlers-Danlos Syndrome (VEDS) is a rare autosomal dominant collagen vascular disorder. Different from other Ehler-Danlos Syndrome subtypes, VEDS has poor prognosis due to severe fragility of connective tissues and association with life-threatening vascular and gastrointestinal complications. Spontaneous splenic rupture is a rare but hazardous complication related to this syndrome. To date, only 2 cases have been reported in the literature. Here we present another case of this uncommon complication, occurring in a 54-year-old woman in clinical follow-up for VEDS who presented with sudden onset of abdominal pain and hypotension. © The Author(s) 2015.

  18. The effects of Ta on the stress rupture properties and microstructural stability of a novel Ni-base superalloy for land-based high temperature applications

    International Nuclear Information System (INIS)

    Zheng, Liang; Zhang, Guoqing; Lee, Tung L.; Gorley, Michael J.; Wang, Yue; Xiao, Chengbo; Li, Zhou

    2014-01-01

    Highlights: • An equiaxed superalloy has high rupture life equivalent to single crystal alloy DD3. • Low Cr and high W superalloys possess good microstructrual stability at 850–1100 °C. • Tantalum promotes, strengthens and stabilizes the eutectic γ′ and MC carbides. • Excessive Ta leads to form harmful abnormal primary α and plate-like M 6 C phases. • Proper Ta can improve the stress rupture life at intermediate and high temperatures. - Abstract: A novel polycrystalline Ni-base superalloy was developed for land-based high temperature applications, such as isothermal forging dies and industrial gas turbines. The alloy possessed surprisingly high stress rupture life of 52 h at 1100 °C/118 MPa which is comparable to the first generation single crystal (SC) superalloy and exhibited good microstructural stability. The effects of Ta addition on the phase change, stress rupture properties and microstructural stability of the alloy were investigated. The results indicated that Ta is a γ′-former and promotes the formation of eutectic γ′. The alloys with ∼7 vol.% eutectic γ′ possess higher stress rupture life at 1100 °C/118 MPa than the alloys with higher ∼20 vol.% eutectic. However, ∼20 vol.% excessive eutectic phases will enhance the stress rupture life at intermediate temperature of 760 °C for 686 MPa but weaken high temperature stress rupture properties. The (Al + Ta) content over 14.4 at.% led to the formation of large amounts of eutectic γ′ and exceeded the solubility of W and Mo in the residue liquid pool, which then promoted the precipitation of primary α-(W,Mo) and M 6 C phases. Tantalum was also found as a strong MC carbides forming element. The order of ability to form monocarbide decreased from NbC to TaC to TiC. 6Al–0Ta (wt.%) alloys possessed good microstructural stability with no harmful topologically close-packed (TCP) phases being observed after thermal exposure at 850 °C/3000 h, 900 °C/1000 h. Only trace amounts of

  19. ACL Rupture in Collegiate Wrestler

    Directory of Open Access Journals (Sweden)

    Lindsay A. Palmer

    2016-05-01

    Full Text Available Objective: To educate others on unique Anterior Cruciate Ligament tears and percentage of usage of the ACL in normal daily function. Background: Patient is an eighteen year old male participating in wrestling and football at the time of the injury. Patient now only participates in wrestling. No previous knee or chronic injuries were reported prior to this injury. Patient was playing football during the time of injury. The patient stated that he planted his foot down and was tackled at the same time when the injury occurred. The patient felt his knee twist and buckle. Patient complained of clicking inside the knee and had minimal swelling. He also complained of it being difficult to bear weight at the time. The patient did not seek further treatment until two months after the injury occurred when he received an MRI. His MRI showed a positive finding for an Anterior Cruciate Ligament rupture. His previous Athletic Trainer could not find a positive diagnosis for the patient prior to the MRI. Differential Diagnosis: Possible meniscal or ACL injury. Treatment: Doctors officially diagnosed the injury as a complete rupture of the ACL. The patient did not receive surgery immediately. Doctors have stated that he only uses about 50% of his ACL on a daily basis compared to a normal person who uses about 95% of their ACL daily. Because of this, the patient played on his rupture for seven months before receiving surgery. He played a whole season of high school football and a whole season of wrestling his senior year with the ACL ruptured. The patient only used a brace for better comfort during the seven months. The patient then received reconstructive surgery to repair the rupture. A hamstring tendon graft was used to repair the ruptured ACL. Because a tendon was taken from the hamstring, patient experienced a tight ACL and hamstring of the left leg post-surgery. The patient participated in Physical Therapy for five months to strengthen and stretch the new

  20. Describing Soils: Calibration Tool for Teaching Soil Rupture Resistance

    Science.gov (United States)

    Seybold, C. A.; Harms, D. S.; Grossman, R. B.

    2009-01-01

    Rupture resistance is a measure of the strength of a soil to withstand an applied stress or resist deformation. In soil survey, during routine soil descriptions, rupture resistance is described for each horizon or layer in the soil profile. The lower portion of the rupture resistance classes are assigned based on rupture between thumb and…

  1. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    International Nuclear Information System (INIS)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E.; Walker, Eric A.

    2015-01-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  2. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    Energy Technology Data Exchange (ETDEWEB)

    Duryea, Dennis; Petscavage-Thomas, Jonelle [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Frauenhoffer, Elizabeth E. [Milton S. Hershey Medical Center, Department of Pathology, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Walker, Eric A. [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Uniformed Services University of the Health Sciences, Department of Radiology and Nuclear Medicine, Bethesda, MD, 20814 (United States)

    2015-08-15

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  3. Dynamic rupture simulation of the 2017 Mw 7.8 Kaikoura (New Zealand) earthquake: Is spontaneous multi-fault rupture expected?

    Science.gov (United States)

    Ando, R.; Kaneko, Y.

    2017-12-01

    The coseismic rupture of the 2016 Kaikoura earthquake propagated over the distance of 150 km along the NE-SW striking fault system in the northern South Island of New Zealand. The analysis of In-SAR, GPS and field observations (Hamling et al., 2017) revealed that the most of the rupture occurred along the previously mapped active faults, involving more than seven major fault segments. These fault segments, mostly dipping to northwest, are distributed in a quite complex manner, manifested by fault branching and step-over structures. Back-projection rupture imaging shows that the rupture appears to jump between three sub-parallel fault segments in sequence from the south to north (Kaiser et al., 2017). The rupture seems to be terminated on the Needles fault in Cook Strait. One of the main questions is whether this multi-fault rupture can be naturally explained with the physical basis. In order to understand the conditions responsible for the complex rupture process, we conduct fully dynamic rupture simulations that account for 3-D non-planar fault geometry embedded in an elastic half-space. The fault geometry is constrained by previous In-SAR observations and geological inferences. The regional stress field is constrained by the result of stress tensor inversion based on focal mechanisms (Balfour et al., 2005). The fault is governed by a relatively simple, slip-weakening friction law. For simplicity, the frictional parameters are uniformly distributed as there is no direct estimate of them except for a shallow portion of the Kekerengu fault (Kaneko et al., 2017). Our simulations show that the rupture can indeed propagate through the complex fault system once it is nucleated at the southernmost segment. The simulated slip distribution is quite heterogeneous, reflecting the nature of non-planar fault geometry, fault branching and step-over structures. We find that optimally oriented faults exhibit larger slip, which is consistent with the slip model of Hamling et al

  4. Uterine rupture without previous caesarean delivery

    DEFF Research Database (Denmark)

    Thisted, Dorthe L. A.; H. Mortensen, Laust; Krebs, Lone

    2015-01-01

    to uterine rupture when adjusted for parity, epidural analgesia and augmentation by oxytocin. CONCLUSION: Although uterine rupture is rare, its association with epidural analgesia and augmentation of labour with oxytocin in multipara should be considered. Thus, vigilance should be exercised when labour...

  5. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  6. Multi-Fault Rupture Scenarios in the Brawley Seismic Zone

    Science.gov (United States)

    Kyriakopoulos, C.; Oglesby, D. D.; Rockwell, T. K.; Meltzner, A. J.; Barall, M.

    2017-12-01

    Dynamic rupture complexity is strongly affected by both the geometric configuration of a network of faults and pre-stress conditions. Between those two, the geometric configuration is more likely to be anticipated prior to an event. An important factor in the unpredictability of the final rupture pattern of a group of faults is the time-dependent interaction between them. Dynamic rupture models provide a means to investigate this otherwise inscrutable processes. The Brawley Seismic Zone in Southern California is an area in which this approach might be important for inferring potential earthquake sizes and rupture patterns. Dynamic modeling can illuminate how the main faults in this area, the Southern San Andreas (SSAF) and Imperial faults, might interact with the intersecting cross faults, and how the cross faults may modulate rupture on the main faults. We perform 3D finite element modeling of potential earthquakes in this zone assuming an extended array of faults (Figure). Our results include a wide range of ruptures and fault behaviors depending on assumptions about nucleation location, geometric setup, pre-stress conditions, and locking depth. For example, in the majority of our models the cross faults do not strongly participate in the rupture process, giving the impression that they are not typically an aid or an obstacle to the rupture propagation. However, in some cases, particularly when rupture proceeds slowly on the main faults, the cross faults indeed can participate with significant slip, and can even cause rupture termination on one of the main faults. Furthermore, in a complex network of faults we should not preclude the possibility of a large event nucleating on a smaller fault (e.g. a cross fault) and eventually promoting rupture on the main structure. Recent examples include the 2010 Mw 7.1 Darfield (New Zealand) and Mw 7.2 El Mayor-Cucapah (Mexico) earthquakes, where rupture started on a smaller adjacent segment and later cascaded into a larger

  7. [Effects of posterior tibial slope on non-contact anterior cruciate ligament rupture and stability of anterior cruciate ligament rupture knee].

    Science.gov (United States)

    Yue, De-bo; E, Sen; Wang, Bai-liang; Wang, Wei-guo; Guo, Wan-shou; Zhang, Qi-dong

    2013-05-07

    To retrospectively explore the correlation between anterior cruciate ligament (ACL)-ruptured knees, stability of ACL-rupture knee and posterior tibial slope (PTS). From January 2008 to October 2012, 150 knees with ACL rupture underwent arthroscopic surgery for ACL reconstruction. A control group was established for subjects undergoing arthroscopic surgery without ACL rupture during the same period. PTS was measured on a digitalized lateral radiograph. Lachman and mechanized pivot shift tests were performed for assessing the stability of knee. There was significant difference (P = 0.007) in PTS angle between the patients with ACL rupture (9.5 ± 2.2 degrees) and the control group (6.6 ± 1.8 degrees). Only among females, increased slope of tibial plateau had effect on the Lachman test. There was a higher positive rate of pivot shift test in patients of increased posterior slope in the ACL rupture group. Increased posterior tibial slope (>6.6) appears to contribute to non-contact ACL injuries in females. And the changes of tibial slope have no effect upon the Lachman test. However, large changes in tibial slope affect pivot shift.

  8. Predictors of in-hospital mortality after mitral valve surgery for post-myocardial infarction papillary muscle rupture

    NARCIS (Netherlands)

    Bouma, Wobbe; Hamer, Inez J. Wijdh-den; Koene, Bart M.; Kuijpers, Michiel; Natour, Ehsan; Erasmus, Michiel E.; van der Horst, Iwan C. C.; Gorman, Joseph H.; Gorman, Robert C.; Mariani, Massimo A.

    2014-01-01

    Background: Papillary muscle rupture (PMR) is a rare, but often life-threatening mechanical complication of myocardial infarction (MI). Immediate surgical intervention is considered the optimal and most rational treatment for acute PMR, but carries high risks. At this point it is not entirely clear

  9. Spontaneous Splenic Rupture in Melanoma

    Directory of Open Access Journals (Sweden)

    Hadi Mirfazaelian

    2014-01-01

    Full Text Available Spontaneous rupture of spleen due to malignant melanoma is a rare situation, with only a few case reports in the literature. This study reports a previously healthy, 30-year-old man who came with chief complaint of acute abdominal pain to emergency room. On physical examination, abdominal tenderness and guarding were detected to be coincident with hypotension. Ultrasonography revealed mild splenomegaly with moderate free fluid in abdominopelvic cavity. Considering acute abdominal pain and hemodynamic instability, he underwent splenectomy with splenic rupture as the source of bleeding. Histologic examination showed diffuse infiltration by tumor. Immunohistochemical study (positive for S100, HMB45, and vimentin and negative for CK, CD10, CK20, CK7, CD30, LCA, EMA, and chromogranin confirmed metastatic malignant melanoma. On further questioning, there was a past history of a nasal dark skin lesion which was removed two years ago with no pathologic examination. Spontaneous (nontraumatic rupture of spleen is an uncommon situation and it happens very rarely due to neoplastic metastasis. Metastasis of malignant melanoma is one of the rare causes of the spontaneous rupture of spleen.

  10. Reliability and validity of the PHQ-9 for screening late-life depression in Chinese primary care.

    Science.gov (United States)

    Chen, Shulin; Chiu, Helen; Xu, Baihua; Ma, Yan; Jin, Tao; Wu, Manhua; Conwell, Yeates

    2010-11-01

    The aim of this study was to examine the reliability and validation of the 9-item Patient Health Questionnaire (PHQ-9) for late-life depression in Chinese primary care. In the primary care clinics (PCCs) of Hangzhou city, we recruited 364 older patients (aged ≥ 60) for the PHQ-9 screening. Then 77 of them were further interviewed with Structured Clinical Interview for DSM Disorders (SCID) for the diagnosis of major depression in late life. Statistic strategies for the feasibility, reliability, validity, and receiver operating characteristic curve were performed. The mean administration time was 7.5 min, and the Cronbach's α was 0.91. The optimal cut-off score of PHQ-9 ≥ 9 revealed a sensitivity of 0.86, specificity of 0.77, and positive likelihood ratio of 5.73. The area under the curve (AUC) in this study was 0.92 (SD = 0.02, 95% CI 0.88-0.96). The PHQ-2 also revealed good sensitivity (0.84) and specificity (0.90) at the cut-off point ≥ 3. The PHQ-9 performs well and has acceptable psychometric properties for screening of patients with late-life depression in Chinese primary care settings.

  11. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  12. The European Portuguese WHOQOL-OLD module and the new facet Family/Family life: reliability and validity studies.

    Science.gov (United States)

    Vilar, Manuela; Sousa, Liliana B; Simões, Mário R

    2016-09-01

    The aim of this study was to examine the psychometric properties of the European Portuguese version of the World Health Organization Quality of Life-Older Adults Module (WHOQOL-OLD). The European Portuguese WHOQOL-OLD includes a new identified facet, Family/Family life. A convenience sample of older adults was recruited (N = 921). The assessment protocol included demographics, self-perceived health, depressive symptoms (GDS-30), cognitive function (ACE-R), daily life activities (IAFAI), health status (SF-12) and QoL (WHOQOL-Bref, EUROHIS-QOL-8 and WHOQOL-OLD). The internal consistency was excellent for the total 24-item WHOQOL-OLD original version and also for the final 28-item European Portuguese WHOQOL-OLD version. The test-retest reliability for total scores was good. The construct validity of the European Portuguese WHOQOL-OLD was supported in the correlation matrix analysis. The results indicated good convergent/divergent validity. The WHOQOL-OLD scores differentiated groups of older adults who were healthy/unhealthy and without/mild/severe depressive symptoms. The new facet, Family/Family life, presented evidence of good reliability and validity parameters. Comparatively to international studies, the European Portuguese WHOQOL-OLD version showed similar and/or better psychometric properties. The new facet, Family/Family life, introduces cross-cultural specificity to the study of QoL of older adults and generally improves the psychometric robustness of the WHOQOL-OLD.

  13. RESEARCH ON REDUCING PREMATURITY RUPTURE OF MEMBRANE

    Directory of Open Access Journals (Sweden)

    Maria URSACHI (BOLOTA

    2016-12-01

    Full Text Available The membranes surrounding the amniotic cavity are composed from amnion and chorion, tightly adherent layers which are composed of several cell types, including epithelial cells, trophoblasts cells and mesenchyme cells, embedded in a collagenous matrix. They retain amniotic fluid, secret substances into the amniotic fluid, as well as to the uterus and protect the fetus against upward infections from urogenital tract. Normally, the membranes it breaks during labor. Premature rupture of the amniotic sac (PRAS is defined as rupture of membranes before the onset of labor. Premature rupture of the fetal membrane, which occurs before 37 weeks of gestation, usually, refers to preterm premature rupture of membranes. Despite advances in the care period, premature rupture of membranes and premature rupture of membranes preterm continue to be regarded as serious obstetric complications. On the term 8% - 10% of pregnant women have premature rupture of membranes; these women are at increased risk of intrauterine infections, where the interval between membrane rupture and expulsion is rolled-over. Premature rupture of membranes preterm occurs in approximately 1% of all pregnancies and is associated with 30% -40% of preterm births. Thus, it is important to identify the cause of pre-term birth (after less than 37 completed weeks of "gestation" and its complications, including respiratory distress syndrome, neonatal infection and intraventricular hemorrhage. Objectives: the development of the protocol of the clinical trial on patients with impending preterm birth, study clinical and statistical on the socio-demographic characteristics of patients with imminent preterm birth; clinical condition of patients and selection of cases that could benefit from the application of interventional therapy; preclinical investigation (biological and imaging of patients with imminent preterm birth; the modality therapy; clinical investigation of the effectiveness of short

  14. Quality of Life among Persons with HIV/AIDS in Iran: Internal Reliability and Validity of an International Instrument and Associated Factors

    Directory of Open Access Journals (Sweden)

    Pedram Razavi

    2012-01-01

    Full Text Available The purpose of this cross-sectional study on 191 HIV/AIDS patient was to prepare the first Persian translation of complete WHOQOL-HIV instrument, evaluate its reliability and validity, and apply it to determine quality of life and its associated factors in Tehran, Iran. Student's t-test was used to compare quality of life between groups. Mean Cronbach’s α of facets in all six domains of instrument were more than 0.6 indicating good reliability. Item/total corrected correlations coefficients had a lower limit of more than 0.5 in all facets except for association between energy and fatigue facet and physical domain. Compared to younger participants, patients older than 35 years had significantly lower scores in overall quality of life (P = 0.003, social relationships (P = 0.021, and spirituality/religion/personal beliefs (P = 0.024. Unemployed patients had significantly lower scores in overall quality of life (P = 0.01, level of independence (P = 0.004, and environment (P = 0.001 compared to employed participants. This study demonstrated that the standard, complete WHOQOL-HIV 120 instrument translated into Farsi and evaluated among Iranian participants provides a reliable and valid basis for future research on quality of life for HIV and other patients in Iran.

  15. The creep life of superheater and reheater tubes under varying pressure conditions in operational boilers

    International Nuclear Information System (INIS)

    Mizen, D.C.; Plastow, B.

    1975-01-01

    The first of each manufacturer's 500 MW boilers supplied to the CEGB (Central Electricity Generating Board) have been subjected to an extensive programme of tests for performance optimization and safe operation. Around 250 thermocouples on superheater and reheater tubes have in each case been monitored as part of the exercise. The readings are corrected and used to compute creep rupture damage based on internationally agreed stress rupture data and a simple cumulative damage concept. Comparison of the design creep rupture life and the cumulative life consumed has in several applications been invaluable in influencing operating procedures and arranging tube modifications or replacements, so that loss of generation by creep rupture failure is minimized. (author)

  16. Development of gamma-ray densitometer and measurement of void fraction in instantaneous pipe rupture under BWR LOCA condition

    International Nuclear Information System (INIS)

    Yano, Toshikazu

    1983-11-01

    In order to clarify the transient mass flow rate under the instantaneous pipe rupture condition, it is necessary to use a highly sensitive void meter. Therefore, a high-response gamma-ray densitometer was developed for the measurement of void fraction variation caused by flashing vaporization of the high-pressure and -temperature water under the instantaneous pipe rupture accident. The measurement of void fraction was performed in the pipe rupture test under the BWR LOCA condition with a 6-inch diameter pipe. Initial conditions of the water were 6.86 MPa in pressure and the saturation temperature. To prove the reliability and accuracy, a calibration test by falling acrylic void simulators and an air injection test into cold water filled in the pipe were also conducted. The following results are obtained in the pipe rupture test. (1) The cone slit method is very useful to increase the measuring accuracy. (2) It is clearly observed that the apparent increase of void fraction occurs after the rarefaction wave passes. (3) The first maximum of void fraction occurs with some delay time after break. The following minimum void fraction concurs with the maximum pressure in the pressure recovering phenomena and with the maximum blowdown thrust force. (author)

  17. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  18. Risk factors affecting chronic rupture of the plantar fascia.

    Science.gov (United States)

    Lee, Ho Seong; Choi, Young Rak; Kim, Sang Woo; Lee, Jin Yong; Seo, Jeong Ho; Jeong, Jae Jung

    2014-03-01

    Prior to 1994, plantar fascia ruptures were considered as an acute injury that occurred primarily in athletes. However, plantar fascia ruptures have recently been reported in the setting of preexisting plantar fasciitis. We analyzed risk factors causing plantar fascia rupture in the presence of preexisting plantar fasciitis. We retrospectively reviewed 286 patients with plantar fasciitis who were referred from private clinics between March 2004 and February 2008. Patients were divided into those with or without a plantar fascia rupture. There were 35 patients in the rupture group and 251 in the nonrupture group. The clinical characteristics and risk factors for plantar fascia rupture were compared between the 2 groups. We compared age, gender, the affected site, visual analog scale pain score, previous treatment regimen, body mass index, degree of ankle dorsiflexion, the use of steroid injections, the extent of activity, calcaneal pitch angle, the presence of a calcaneal spur, and heel alignment between the 2 groups. Of the assessed risk factors, only steroid injection was associated with the occurrence of a plantar fascia rupture. Among the 35 patients with a rupture, 33 had received steroid injections. The odds ratio of steroid injection was 33. Steroid injections for plantar fasciitis should be cautiously administered because of the higher risk for plantar fascia rupture. Level III, retrospective comparative study.

  19. Technical meeting on 'Primary coolant pipe rupture event in liquid metal cooled fast reactors'. Working material

    International Nuclear Information System (INIS)

    2003-01-01

    In Liquid Metal cooled Fast Reactors (LMFR) or in accelerator driven sub-critical systems (ADS) with LMFR like sub-critical cores, the primary coolant pipes (PCP) connect the primary coolant pumps to the grid plate. A rupture in one of these pipes could cause significant loss of coolant flow to the core with severe consequences. In loop type reactors, all primary pipelines are provided with double envelopes and inter-space coolant leak monitoring systems that permit leak detection before break. Thus, the PCP rupture event can be placed in the beyond design basis event (BDBE) category. Such an arrangement is difficult to incorporate for pool type reactors, and hence it could be argued that the PCP rupture event needs to be analysed in detail as a design basis event (DBE, category 4 event). The primary coolant pipes are made of ductile austenitic stainless steel material and operate at temperatures of the cold pool and at comparatively low pressures. For such low stressed piping with negligible creep and embrittlement effects, it is of interest to discuss under what design provisions, for pool type reactors, the guillotine rupture of PCP could be placed in the BDBE category. The topical Technical Meeting (TM) on 'Primary Coolant Pipe Rupture Event in Liquid Metal Cooled Reactors' was called to enable the specialists to present the philosophy and analyses applied on this topic in the various Member States for different LMFRs. The scope of the Technical Meeting was to provide a global forum for information exchange on the philosophy applied in the various participating Member States and the analyses performed for different LMFRs with regard to the primary coolant pipe rupture event. More specifically, the objectives of the Technical Meeting were to review the safety philosophy for the PCP rupture event in pool type LMFR, to assess the structural reliability of the PCP and the probability of rupture under different conditions (with/without in-service inspection), to

  20. The Persian Version of the "Life Satisfaction Scale": Construct Validity and Test-Re-Test Reliability among Iranian Older Adults.

    Science.gov (United States)

    Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari

    2018-03-01

    After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.

  1. Cognitive frames in psychology: demarcations and ruptures.

    Science.gov (United States)

    Yurevich, Andrey V

    2009-06-01

    As there seems to be a recurrent feeling of crisis in psychology, its present state is analyzed in this article. The author believes that in addition to the traditional manifestations that have dogged psychology since it emerged as an independent science some new features of the crisis have emerged. Three fundamental "ruptures" are identified: the "horizontal" rupture between various schools and trends, the "vertical" rupture between natural science and humanitarian psychology, and the "diagonal" rupture between academic research and applied practice of psychology. These manifestations of the crisis of psychology have recently been compounded by the crisis of its rationalistic foundations. This situation is described in terms of the cognitive systems in psychology which include meta-theories, paradigms, sociodigms and metadigms.

  2. Induced seismicity provides insight into why earthquake ruptures stop

    KAUST Repository

    Galis, Martin

    2017-12-21

    Injection-induced earthquakes pose a serious seismic hazard but also offer an opportunity to gain insight into earthquake physics. Currently used models relating the maximum magnitude of injection-induced earthquakes to injection parameters do not incorporate rupture physics. We develop theoretical estimates, validated by simulations, of the size of ruptures induced by localized pore-pressure perturbations and propagating on prestressed faults. Our model accounts for ruptures growing beyond the perturbed area and distinguishes self-arrested from runaway ruptures. We develop a theoretical scaling relation between the largest magnitude of self-arrested earthquakes and the injected volume and find it consistent with observed maximum magnitudes of injection-induced earthquakes over a broad range of injected volumes, suggesting that, although runaway ruptures are possible, most injection-induced events so far have been self-arrested ruptures.

  3. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    Science.gov (United States)

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria

  4. Challenging Friesian horse diseases : aortic rupture and megaesophagus

    NARCIS (Netherlands)

    Ploeg, M.

    2015-01-01

    Aortic rupture is quite rare in Warmblood horses and is best known as an acute and fatal rupture of the aortic root in older breeding stallions. It has now become clear that aortic rupture, which is diagnosed around an age of 4 years, is more frequent in the Friesian breed than in others. The high

  5. Primary coolant pipe rupture event in liquid metal cooled reactors. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2004-08-01

    In liquid-metal cooled fast reactors (LMFR) the primary coolant pipes (PCP) connect the primary coolant pumps to the grid plate. A rupture in one of these pipes could cause significant loss of coolant flow to the core with severe consequences. In loop type reactors, all primary pipelines are provided with double envelopes and inter-space coolant leak monitoring systems that permit leak detection before break. Thus, the PCP rupture event can be placed in the beyond design basis event (BDBE) category. Such an arrangement is difficult to incorporate for pool type reactors, and hence it could be argued that the PCP rupture event needs to be analysed in detail as a design basis event (DBE, category 4 event). However, the primary coolant pipes are made of ductile austenitic stainless steel material and operate at temperatures of the cold pool and at comparatively low pressures. For such low stressed piping with negligible creep and embrittlement effects, it is of interest to discuss under what design provisions, for pool type reactors, the guillotine rupture of PCP could be placed in the BDBE category. The topical Technical Meeting (TM) on Primary Coolant Pipe Rupture Event in Liquid Metal Cooled Reactors (Indira Gandhi Centre for Atomic Research, Kalpakkam, India, 13-17 January 2003) was called to enable the specialists to present the philosophy and analyses applied on this topic in the various Member States for different LMFRs. The scope of the technical meeting was to provide a global forum for information exchange on the philosophy applied in the various participating Member States and the analyses performed for different LMFRs with regard to the primary coolant pipe rupture event. More specifically, the objectives of the technical meeting were to review the safety philosophy for the PCP rupture event in pool type LMFR, to assess the structural reliability of the PCP and the probability of rupture under different conditions (with/without in-service inspection), to

  6. Pre-term Spontaneous Unscarred Uterine Rupture; A Case Report and Review

    OpenAIRE

    Shima Sheybani; Nahid Zirak; Razieh Poorandi; Elnaz Hosseini

    2014-01-01

    Introduction: Spontaneous uterine rupture, a life-threatening condition for both parturient and their fetus, often tends to occur during labour, particularly in those with a scarred uterus (rare in unscarred ones). The diagnosis must be born in mind in case of a pregnant woman presenting with shock, abdominal pain and diminished fetal heart rate. Any additional preoperative evaluation seems redundant as it only wastes golden surgical time. Case:The case we intend to present is a multigravi...

  7. Spontaneous rupture of the esophagus associated with intramural rupture caused by ingestion of weeding medicine (Lasso)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Keon; Park, Heung Il; Kwun, Chung Sik [Chun Nam University College of Medicine, Kwangju (Korea, Republic of)

    1975-06-15

    This is a report of a case of spontaneous rupture of the esophagus associated with intramural rupture caused by ingestion of weeding medicine for the purpose of suicide in a 27 year old Korean male whose chief complaints were dyspnea, epigastric pain, swallowing disturbance, and hoarseness for 3 days prior to admission. A review of literature is submitted.

  8. Spontaneous esophageal rupture - Boerhaave's syndrome: Clinical symptoms and radiographic findings

    International Nuclear Information System (INIS)

    Gaa, J.; Deininger, H.K.

    1989-01-01

    Spontaneous transmural rupture of the esophagus (Boerhaave's syndrome) is a life-threatening emergency. Prompt diagnosis is essential to a better prognosis, successful operative outcome and patient survival. The chest roentgenogram and the contrast esophagograms to follow are the most helpful diagnostic tests. The clinical manifestations are variable and may be misleading and thus delay accurate recognition. In our case report the major clinical features and radiological signs of Boerhaave's syndrome are described. The pathogenesis, characteristic clinical symptoms and the signs and radiological evaluation are reviewed. (orig.) [de

  9. Sodium component reliability data collection at CREDO

    International Nuclear Information System (INIS)

    Bott, T.F.; Haas, P.M.; Manning, J.J.

    1979-01-01

    The Centralized Reliability Data Organization (CREDO) has been established at Oak Ridge National Laboratory (ORNL) by the Department of Energy to provide a national center for collection, evaluation and dissemination of reliability data for advanced reactors. While the system is being developed and continuous data collection at the two U.S. reactor sites (EBR-II and FFTF) is being established, data on advanced reactor components which have been in use at U.S. test loops and experimental reactors have been collected and analyzed. Engineering, operating and event data on sodium valves, pumps, flow meters, rupture discs, heat exchangers and cold traps have been collected from more than a dozen sites. The results of analyses of the data performed to date are presented

  10. Ruptured rectal duplication with urogenital abnormality: Unusual presentation.

    Science.gov (United States)

    Solanki, Shailesh; Babu, M Narendra; Jadhav, Vinay; Shankar, Gowri; Santhanakrishnan, Ramesh

    2015-01-01

    Rectal duplication (RD) accounts for 5% of alimentary tract duplication. A varied presentation and associated anomalies have been described in the literature. Antenatal rupture of the RD is very rare. We present an unusual case of a ruptured RD associated with urogenital abnormalities in newborn male. We are discussing diagnosis, embryology, management and literature review of ruptured RD.

  11. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  12. Spontaneous Spleen Rupture in a Teenager: An Uncommon Cause of Acute Abdomen

    Directory of Open Access Journals (Sweden)

    Verroiotou Maria

    2013-01-01

    Full Text Available Spontaneous spleen rupture is a rare complication of infectious diseases and it can become a potentially life-threatening condition if not diagnosed in time. A 17-year-old Greek female presented to the ER due to acute abdominal pain, mainly of the left upper quadrant. She had no recent report of trauma. The patient was pale, her blood pressure was 90/70 mmHg, and her pulse was 120 b/min. Clinical examination of the abdomen revealed muscle contraction and resistance. The patient was submitted to an ultrasound of the upper abdomen and to a CT scanning of the abdomen that revealed an extended intraperitoneal hemorrhage due to spleen rupture. Due to the patient’s hemodynamic instability, she was taken to the operation room and splenectomy was performed. Following a series of laboratory examinations, the patient was diagnosed to be positive for current cytomegalovirus infection. The postoperative course was uneventful, and in a two year follow-up the patient is symptom-free. Spontaneous spleen rupture due to Cytomegalovirus infection is a rare clinical entity, described in few case reports in the world literature and should always be taken into consideration in differential diagnosis of acute abdomen, especially in adolescents with no recent report of trauma.

  13. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  14. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  15. Cyclic creep-rupture behavior of three high-temperature alloys.

    Science.gov (United States)

    Halford, G. R.

    1972-01-01

    Study of some important characteristics of the cyclic creep-rupture curves for the titanium alloy 6Al-2Sn-4Zr-2Mo at 900 and 1100 F (755 and 865 K), the cobalt-base alloy L-605 at 1180 F (910 K), and for two hardness levels of 316 stainless steel at 1300 F (980 K). The cyclic creep-rupture curve relates tensile stress and tensile time-to-rupture for strain-limited cyclic loading and has been found to be independent of the total strain range and the level of compressive stress employed in the cyclic creep-rupture tests. The cyclic creep-rupture curve was always found to be above and to the right of the conventional (constant load) monotonic creep-rupture curve by factors ranging from 2 to 10 in time-to-rupture. This factor tends to be greatest when the creep ductility is large. Cyclic creep acceleration was observed in every cyclic creep-rupture test conducted. The phenomenon was most pronounced at the highest stress levels and when the tensile and compressive stresses were completely reversed. In general, creep rates were found to be lower in compression than in tension for equal true stresses. The differences, however, were strongly material-dependent.

  16. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  17. Rupture of the urinary bladder after minimal trauma

    International Nuclear Information System (INIS)

    Myrseth, L.E.; Johansen, T.E.B.

    1991-01-01

    Rupture of the urinary bladder is a rare injury most often encountered after severe trauma and in conjunction with injuries to other organ systems. It may occur, however, without concomitant injury and also after minimal trauma. This diagnosis must be suspected in a patient with abdominal pain who is unable to void or who presents hematuria. The diagnosis is made by means of a retrograde cystogram using 350-400 ml contrast medium and supplemented by a drainage film. Intrapertioneal ruptures should be treated surgically by closure in layers, and drainage. Patients with extraperitoneal ruptures can safely be treated with simple catheter drainage until the rupture has healed, usually within 10-20 days. The authors report three cases of bladder rupture after minimal trauma and describe the state of the art of diagnosis and treatment of these injuries. 15 refs., 3 figs

  18. Computed tomography features and predictive findings of ruptured gastrointestinal stromal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Sil; Kim, Hyun Jin; Park, Seong Ho; Lee, Jong Seok; Kim, Ah Young; Ha, Hyun Kwon [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Songpa-Gu, Seoul (Korea, Republic of)

    2017-06-15

    To evaluate the CT features of ruptured GISTs and factors that might be predictive of rupture through comparison with CTs taken prior to rupture and CTs of non-ruptured GIST. Forty-nine patients with ruptured GIST and forty-nine patients with non-ruptured GIST matched by age, gender and location were included. Clinical data including pharmacotherapy were reviewed. The imaging features were analyzed. Prior CT obtained before rupture were evaluated. The most common location of ruptured GIST was small bowel with mean size of 12.1 cm. Ruptured GIST commonly showed wall defects, >40 % eccentric necrosis, lobulated shaped, air density in mass, pneumoperitoneum, peritonitis, hemoperitoneum and ascites (p < 0.001-0.030). Twenty-seven of 30 patients with follow up imaging received targeted therapy. During follow-up, thickness of the tumour wall decreased. Increase in size and progression of necrosis were common during targeted therapy (p = 0.017). Newly developed ascites, peritonitis and hemoperitoneum was more common (p < 0.001-0.036). Ruptured GISTs commonly demonstrate large size, >40 % eccentric necrosis, wall defects and lobulated shape. The progression of necrosis with increase in size and decreased wall thickness during targeted therapy may increase the risk of rupture. Rupture should be considered when newly developed peritonitis, hemoperitoneum, or ascites are noted during the follow-up. (orig.)

  19. Diaphragmatic rupture causing repeated vomiting in a combined abdominal and head injury patient: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Symeonidis Dimitrios

    2012-07-01

    Full Text Available Abstract Background Diaphragmatic rupture after blunt abdominal injury is a rare trauma condition. Delayed diagnosis is not uncommon especially in the emergency room setting. Associated injuries often shift diagnosis and treatment priorities towards other more life-threatening conditions. Case presentation We present a challenging case of a young male with combined abdominal and head trauma. Repeated episodes of vomiting dominated on clinical presentation that in the presence of a deep scalp laceration and facial bruising shifted differential diagnosis towards a traumatic brain injury. However, a computed tomography scan of the brain ruled out any intracranial pathology. Finally, a more meticulous investigation with additional imaging studies confirmed the presence of diaphragmatic rupture that justified the clinical symptoms. Conclusions The combination of diaphragmatic rupture with head injury creates a challenging trauma scenario. Increased level of suspicion is essential in order to diagnose timely diaphragmatic rupture in multiple trauma patients.

  20. Development of rupture discs for the FBTR

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, C.; Anandkumar, V.; Seetharaman, V.; Rajan, K.K.

    1984-01-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. Reverse buckling knife blade concept with austenitic stainless steel disc has been developed for the rupture disc assemblies required for Fast Breeder Test Reactor (FBTR). Hydroforming process without any die has been used for disc fabrication. One rupture disc assembly required for steam generator is undergoing sodium endurance test and has accumulated 4,500 hours. The present status of development work as demonstrated by room temperature experimental results as well as the scope for future work are discussed. (author)

  1. Hemoperitoneum due to ruptured paraumbilical vein in a cirrhotic patient with portal hypertension : treatment by means of coil embolization

    International Nuclear Information System (INIS)

    Lee, Jong Myeong; Kim, Hyung Lyul; Lee, Young Hwan; Lee, So Hyun; Kim, Jong Kun

    2000-01-01

    The paraumbilical vein is one of the anastomotic channels between the portal and systemic circulatory systems, and rupture of the intra-abdominal varix is an unusual complication of portal hypertension that can lead to life-threatening hemoperitoneum. We experienced a case of hemoperitoneum due to a ruptured paraumbilical vein revealed by ultrasonography (US), computed tomography (CT) and percutaneous transhepatic portography. The last mentioned demonstrated a dilated paraumbilical vein draining two branches of the left portal vein into the right external iliac vein, and we performed coil embolization at the site at which the presumed site of paraumbilical vein was presumed to cause hemoperitoneum. We describe this this unusual case of hemoperitoneum due to a ruptured paraumbilical vein in a known liver cirrhosis patient in whom portal hypertension was treated by means of coil embolization. (author)

  2. Bladder And Uterine Rupture At Vaginal Birth After Cesarean Section

    African Journals Online (AJOL)

    Rupture of the uterus is still a major obstetric problem in developing countries. The urinary bladder is often affected especially when a lower segment Caesarean scar ruptures. We present a case of bladder rupture associated with uterine rupture in a patient who was attempting vaginal delivery after two previous Caesarean ...

  3. Radionuclide diagnosis of splenic rupture in infectious mononucleosis

    International Nuclear Information System (INIS)

    Vezina, W.C.; Nicholson, R.L.; Cohen, P.; Chamberlain, M.J.

    1984-01-01

    Spontaneous splenic rupture is a rare but serious complication of infectious mononucleosis. Although radionuclide spleen imaging is a well accepted method for diagnosis of traumatic rupture, interpretation can be difficult in the setting of mononucleosis, as tears may be ill-defined and diagnosis hampered by inhomogeneous splenic uptake. Four proven cases of spontaneous rupture are presented, three of which illustrate these diagnostic problems

  4. Ruptured rectal duplication with urogenital abnormality: Unusual presentation

    Directory of Open Access Journals (Sweden)

    Shailesh Solanki

    2015-01-01

    Full Text Available Rectal duplication (RD accounts for 5% of alimentary tract duplication. A varied presentation and associated anomalies have been described in the literature. Antenatal rupture of the RD is very rare. We present an unusual case of a ruptured RD associated with urogenital abnormalities in newborn male. We are discussing diagnosis, embryology, management and literature review of ruptured RD.

  5. Axillary lymph nodes siliconoma in a woman with intracapsular implant rupture

    International Nuclear Information System (INIS)

    Plachkov, I.; Cvetankov, K.; Hadjidekov, G.

    2013-01-01

    Full text: Introduction: Siliconoma, or silicone granuloma is the migration of silicon particles in the axillary lymph nodes, muscle and other non- ruptured or intact silicone implant. The latter is a relatively rare finding, and usually occurs in patients with extracapsular rupture of silicone prosthesis and has a typical ultrasound image. We present a case of a young woman with bilateral silicone prostheses placed 5 years ago, where in the right axilla are enlarged, structurally altered lymph nodes in the clinical and ultrasonography studies. Subsequent magnetic resonance examination shows intracapsular rupture ipsilateral silicone prosthesis and migration of silicon particles in the axillary lymph nodes. What you will learn: In this case we present twenty-three year old woman who reported pain and ‘swelling’ in the right axilla. The patient is with bilateral silicone prosthesis, she is not febrile and not reported other illness. After physical examination enlarged and tender lymph nodes in the right axilla was found. Several structurally altered and enlarged lymph nodes were visualized by ultrasound. These lymph nodes are hypoechogenic with obliterated fatty hilus. Due to the suspicion of silicone ‘extravasation’ in axillary lymph nodes, a magnetic resonance study of both mammary glands was performed. The images show intracapsular rupture of the right prosthesis without reliable data on silicone gel outside the fibrous capsule. Discussion: Siliconoma is a complication after plastic surgery of the breast and can affect both the axillary lymph nodes, and other lymphatic chains and also muscle and lung. Most frequently it occurs at damage of the extracapsular silicone prostheses. More rarely siliconoma occurs in siliconoma intracapsular damage, as in the presented case or in a silicone gel microbleed. Conclusion: The presence of siliconoma in axillary lymph nodes is relatively rare complication in plastic surgery of the breast. Methods of imaging diagnostic

  6. Splenic rupture in infectious mononucleosis: A systematic review of published case reports.

    Science.gov (United States)

    Bartlett, A; Williams, R; Hilton, M

    2016-03-01

    Infectious mononucleosis (IM) is a common viral illness that predominantly causes sore throat, fever and cervical lymphadenopathy in adolescents and young adults. Although usually a benign, self-limiting disease, it is associated with a small risk of splenic rupture, which can be life-threatening. It is common practice therefore to advise avoiding vigorous physical activity for at least 4-6 weeks, however this is not based on controlled trials or national guidelines. We reviewed published case reports of splenic rupture occurring in the context of IM in an attempt to ascertain common factors that may predict who is at risk. A search of MEDLINE and EMBASE databases was performed for case reports or series published between 1984 and 2014. In total, 52 articles or abstracts reported 85 cases. Data was extracted and compiled into a Microsoft Excel(®) spreadsheet. The average patient age was 22 years, the majority (70%) being male. The average time between onset of IM symptoms and splenic rupture was 14 days, with a range up to 8 weeks. There was a preceding history of trauma reported in only 14%. Abdominal pain was the commonest presenting complaint of splenic rupture, being present in 88%. 32% were successfully managed non-operatively, whereas 67% underwent splenectomy. Overall mortality was 9%. From our data, it appears that men under 30 within 4 weeks of symptom onset are at highest risk of splenic rupture, therefore particular vigilance in this group is required. As cases have occurred up to 8 weeks after the onset of illness, we would recommend avoidance of sports, heavy lifting and vigorous activity for 8 weeks. Should the patient wish to return to high risk activities prior to this, an USS should be performed to ensure resolution of splenomegaly. The majority of cases reviewed had no preceding trauma, although previous studies have suggested this may be so minor as to go unnoticed by the patient. It is therefore prudent to warn patients about the symptoms of

  7. Spontaneous distal rupture of the plantar fascia.

    Science.gov (United States)

    Gitto, Salvatore; Draghi, Ferdinando

    2018-07-01

    Spontaneous ruptures of the plantar fascia are uncommon injuries. They typically occur at its calcaneal insertion and usually represent a complication of plantar fasciitis and local treatment with steroid injections. In contrast, distal ruptures commonly result from traumatic injuries. We describe the case of a spontaneous distal rupture of the plantar fascia in a 48-year-old woman with a low level of physical activity and no history of direct injury to the foot, plantar fasciitis, or steroid injections. © 2017 Wiley Periodicals, Inc.

  8. Ruptured Uterus At Afikpo, Southeast Nigeria. | Eze | Ebonyi Medical ...

    African Journals Online (AJOL)

    Context: Ruptured uterus is an obstetric catastrophe associated with high maternal and perinatal mortality. Objectives: To determine the incidence, causes, management and fetomaternal outcomes of ruptured uterus in Afikpo, Southeast Nigeria. Methods: Delivery records, theatre registers and case notes of all ruptured ...

  9. Location of Ruptured Bullae in Secondary Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Jinseok Choi

    2017-12-01

    Full Text Available Background: The surgical treatment of secondary spontaneous pneumothorax (SSP can be complicated by fragile lung parenchyma. The preoperative prediction of air leakage could help prevent intraoperative lung in-jury during manipulation of the lung. Common sites of bulla development and ruptured bullae were inves-tigated based on computed tomography (CT and intraoperative findings. Methods: The study enrolled 208 patients with SSP who underwent air leak control through video-assisted thoracoscopic surgery (VATS. We retrospectively reviewed the sites of bulla development on preoperative CT and the rupture sites during VATS. Results: Of the 135 cases of right-sided SSP, the most common rupture site was the apical segment (31.9%, followed by the azygoesophageal recess (27.4%. Of the 75 cases on the left side, the most com-mon rupture site was the apical segment (24.0%, followed by the anterior basal segment (17.3%. Conclusion: The azygoesophageal recess and parenchyma along the cardiac border were common sites of bul-la development and rupture. Studies of respiratory lung motion to measure the pleural pressure at the lung surface could help to determine the relationship between cardiogenic and diaphragmatic movement and bulla formation or rupture.

  10. Retrieving rupture history using waveform inversions in time sequence

    Science.gov (United States)

    Yi, L.; Xu, C.; Zhang, X.

    2017-12-01

    The rupture history of large earthquakes is generally regenerated using the waveform inversion through utilizing seismological waveform records. In the waveform inversion, based on the superposition principle, the rupture process is linearly parameterized. After discretizing the fault plane into sub-faults, the local source time function of each sub-fault is usually parameterized using the multi-time window method, e.g., mutual overlapped triangular functions. Then the forward waveform of each sub-fault is synthesized through convoluting the source time function with its Green function. According to the superposition principle, these forward waveforms generated from the fault plane are summarized in the recorded waveforms after aligning the arrival times. Then the slip history is retrieved using the waveform inversion method after the superposing of all forward waveforms for each correspond seismological waveform records. Apart from the isolation of these forward waveforms generated from each sub-fault, we also realize that these waveforms are gradually and sequentially superimposed in the recorded waveforms. Thus we proposed a idea that the rupture model is possibly detachable in sequent rupture times. According to the constrained waveform length method emphasized in our previous work, the length of inverted waveforms used in the waveform inversion is objectively constrained by the rupture velocity and rise time. And one essential prior condition is the predetermined fault plane that limits the duration of rupture time, which means the waveform inversion is restricted in a pre-set rupture duration time. Therefore, we proposed a strategy to inverse the rupture process sequentially using the progressively shift rupture times as the rupture front expanding in the fault plane. And we have designed a simulation inversion to test the feasibility of the method. Our test result shows the prospect of this idea that requiring furthermore investigation.

  11. Life Prediction on a T700 Carbon Fiber Reinforced Cylinder with Limited Accelerated Life Testing Data

    Directory of Open Access Journals (Sweden)

    Ma Xiaobing

    2015-01-01

    Full Text Available An accelerated life testing investigation was conducted on a composite cylinder that consists of aluminum alloy and T700 carbon fiber. The ultimate failure stress predictions of cylinders were obtained by the mixing rule and verified by the blasting static pressure method. Based on the stress prediction of cylinder under working conditions, the constant stress accelerated life test of the cylinder was designed. However, the failure data cannot be sufficiently obtained by the accelerated life test due to the time limitation. Therefore, most of the data presented to be high censored in high stress level and zero-failure data in low stress level. When using the traditional method for rupture life prediction, the results showed to be of lower confidence. In this study, the consistency of failure mechanism for carbon fiber and cylinder was analyzed firstly. According to the analysis result, the statistical test information of carbon fiber could be utilized for the accelerated model constitution. Then, rupture life prediction method for cylinder was proposed based on the accelerated life test data and carbon fiber test data. In this way, the life prediction accuracy of cylinder could be improved obviously, and the results showed that the accuracy of this method increased by 35%.

  12. The validity and reliability of Systemic Lupus Erythematosus Quality of Life Questionnaire (L-QoL) in a Turkish population.

    Science.gov (United States)

    Duruöz, M T; Unal, C; Toprak, C Sanal; Sezer, I; Yilmaz, F; Ulutatar, F; Atagündüz, P; Baklacioglu, H S

    2017-12-01

    Background Systemic lupus erythematosus (SLE) may have a profound impact on quality of life. There is increasing interest in measuring quality of life in lupus patients. The purpose of this study was to investigate the validity and reliability of SLE Quality of Life Questionnaire (L-QoL) in Turkish SLE patients. Methods SLE according to 2012 Systemic Lupus International Collaborating Clinics Classification Criteria were recruited into the study. Demographic data, clinical parameters and disease activity measured with the Systemic Lupus Erythematosus Disease Activity Index-2000 (SLEDAI-2K); were noted. Nottingham Health Profile and Health Assessment Questionnaire were filled out in addition to the Turkish L-QoL (LQoL-TR). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. Results The mean age of participants was 43.55 ± 14.33 years and the mean disease duration was 89.8 ± 92.1 months. The patients filled out LQoL-TR in 2.5 min. Strong correlation of LQoL-TR with all subgroups of the Nottingham Health Profile and the Health Assessment Questionnaire were established showing the convergent validity. The highest correlation was demonstrated with emotional reactions (rho = 0.72) and sleep component (rho = 0.65) of the Nottingham Health Profile scale ( p < 0.0001). Its poor and not significant correlation with nonfunctional parameters (age, disease duration, perceived general health, SLEDAI-2K) showed its discriminative properties. LQoL-TR demonstrated good internal reliability with a Cronbach's α of 0.93 and test-retest reliability with intraclass correlation coefficient of 0.87. Conclusion The LQoL-TR is a practical and useful tool which demonstrates good validity and reliability.

  13. Life Cycle Assessment for desalination: a review on methodology feasibility and reliability.

    Science.gov (United States)

    Zhou, Jin; Chang, Victor W-C; Fane, Anthony G

    2014-09-15

    As concerns of natural resource depletion and environmental degradation caused by desalination increase, research studies of the environmental sustainability of desalination are growing in importance. Life Cycle Assessment (LCA) is an ISO standardized method and is widely applied to evaluate the environmental performance of desalination. This study reviews more than 30 desalination LCA studies since 2000s and identifies two major issues in need of improvement. The first is feasibility, covering three elements that support the implementation of the LCA to desalination, including accounting methods, supporting databases, and life cycle impact assessment approaches. The second is reliability, addressing three essential aspects that drive uncertainty in results, including the incompleteness of the system boundary, the unrepresentativeness of the database, and the omission of uncertainty analysis. This work can serve as a preliminary LCA reference for desalination specialists, but will also strengthen LCA as an effective method to evaluate the environment footprint of desalination alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Metallurgical analysis of high pressure gas pipelines rupture

    International Nuclear Information System (INIS)

    Hasan, F.; Ahmed, F.

    2007-01-01

    On 6 July 2004, two parallel-running gas pipelines (18-inch and 24-inch diameters), in the main transmission network of SNGPL (a gas company in Pakistan) were ruptured. The ruptures occurred in the early hours of the morning about 8 miles downstream of the compressor station AC-4. The ruptures were indicated by the increased gas flow at the outlet of AC-4 (1), first at about 0648 hours and then again about 20 minutes later. The gas escaping from the ruptured lines had caught fire, and the flames had also 'affected' a third parallel-running pipeline of 30-inch diameter, lying next to the 24-inch line. The metallurgical examination of the two ruptured lines showed that the 24-inch line was ruptured with the help of an explosive device that had been placed on the underside of the pipe. An examination of the 18-inch line showed that this pipe had failed as a result of the heating of the pipe-wall, presumably, by the flame emanating from the 24-inch line. These two observations clearly suggested that the 24-inch line was the first to rupture (by explosives), and the fire following this rupture had heated the 18-inch pipe to a temperature where its yield strength was unable to support the inside gas pressure. The 20 minutes time interval between the two ruptures was obviously the time taken by the 18 inch pipe to be heated upto the level where it started to yield. The 30-inch line lying next to the 24-inch line was affected to the extent that its coating had been burnt-off over a length of about 40-50 feet. However, the pipe did not exhibit any signs of deshaping or deformation what-so-ever. A replica metallographic examination indicated that the microstructure of the pipe was not measurably affected by the heat. It was thus decided not to replace the affected part of the 30-inch pipe, but only to re-coat this affected portion. (author)

  15. On the unit rupture work of metals and alloys

    International Nuclear Information System (INIS)

    Verkhoturov, A.D.; Kovalenko, V.S.; Dyatel, V.P.

    1980-01-01

    Studied is the effect of the nature of the treated material treatment regimes on their unit rupture work at laser treatment in the regime of quasistationary evaporation. It is shown that the unit rupture work changes its values depending on the treatment regimes, coincidences between experimental and calculation values of unit rupture work are not being observed, especially for refractory metals of the 6th group and for solid alloys. Established are optimum regimes for determination of stable values of unit rupture work

  16. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Treatment Alternative for Irreparable Rotator Cuff Ruptures ...

    African Journals Online (AJOL)

    2016-09-03

    Sep 3, 2016 ... and such ruptures also lead to a pseudo-paralysis.[1,2]. Pain during daily ... 2) repairable rotator cuff rupture, as determined on MRI and during arthroscopy ..... functioning and lead to cosmetic deformities.[4]. Arthroplasty is a ...

  18. Reliability and acceptability of the Multiple Sclerosis Quality of Life-29 questionnaire in an English-speaking cohort.

    Science.gov (United States)

    Baker, Georgina; Nair, Krishnan Padmakumari Sivaraman; Baster, Kathleen; Rosato, Rosalba; Solari, Alessandra

    2018-05-01

    Multiple Sclerosis Quality-of-Life Questionnaire-54 (MSQoL-54) is a disease-specific instrument for assessing health-related quality of life (HRQoL). Due to the number of items, the time taken to complete it is long. A shorter 29-item version, Multiple Sclerosis Quality-of-Life Questionnaire-29 (MSQoL-29) is yet to be evaluated in English. To assess reliability and acceptability of English version of MSQoL-29. Among 100 participants with MS who first completed both MSQoL-54 and MSQoL-29, 91 completed MSQoL-29 after 4-8 weeks. We looked for internal consistency (Cronbach's alpha), acceptability, reliability (intraclass correlation coefficients (ICCs)) and agreement (Bland-Altman plots). ICCs were strongly positive between MSQoL-54 and MSQoL-29 (Physical Health Composite (PHC) -ICC = 0.914, confidence interval (CI) = 0.872-0.942; Mental Health Composite (MHC) - ICC = 0.875, CI = 0.814-0.916) and between the two MSQoL-29 (PHC - ICC = 0.970, CI = 0.955-0.980; MHC - ICC = 0.937, CI = 0.904-0.958). On Bland-Altman plots, the MSQoL-29 scores of 95% of participants during two visits were within the limits of agreement (LOAs). Time taken to complete MSQoL-29 was 7.2 ± 2.9 minutes and MSQoL-54 was 19.79 ± 5.4 minutes ( p = 0.0001). MSQoL-29 has good test-retest reliability in English-speaking population and was quicker to complete.

  19. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  20. Incidence of plantar fascia ruptures following corticosteroid injection.

    Science.gov (United States)

    Kim, Chul; Cashdollar, Michael R; Mendicino, Robert W; Catanzariti, Alan R; Fuge, LaDonna

    2010-12-01

    Plantar fasciitis is commonly treated with corticosteroid injections to decrease pain and inflammation. Therapeutic benefits often vary in terms of efficacy and duration. Rupture of the plantar fascia has been reported as a possible complication following corticosteroid injection. A retrospective chart review of 120 patients who received corticosteroid injection for plantar fasciitis was performed at the authors' institution to determine the incidence of plantar fascia rupture. The plantar fascia rupture was diagnosed clinically and confirmed with magnetic resonance imaging. Various factors were analyzed, including the number of injections, interval between injections, body mass index (BMI), and activity level. Four patients (2.4%) consequently experienced plantar fascia rupture following an average of 2.67 injections. The average BMI of these patients was 38.6 kg/m². The authors conclude that corticosteroid injection therapy appears to be a safe and effective form of nonoperative treatment with minimal complications and a relatively low incident of plantar fascia rupture.

  1. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  2. Vortex dynamics in ruptured and unruptured intracranial aneurysms

    Science.gov (United States)

    Trylesinski, Gabriel

    Intracranial aneurysms (IAs) are a potentially devastating pathological dilation of brain arteries that affect 1.5-5 % of the population. Causing around 500 000 deaths per year worldwide, their detection and treatment to prevent rupture is critical. Multiple recent studies have tried to find a hemodynamics predictor of aneurysm rupture, but concluded with distinct opposite trends using Wall Shear Stress (WSS) based parameters in different clinical datasets. Nevertheless, several research groups tend to converge for now on the fact that the flow patterns and flow dynamics of the ruptured aneurysms are complex and unstable. Following this idea, we investigated the vortex properties of both unruptured and ruptured cerebral aneurysms. A brief comparison of two Eulerian vortex visualization methods (Q-criterion and lambda 2 method) showed that these approaches gave similar results in our complex aneurysm geometries. We were then able to apply either one of them to a large dataset of 74 patient specific cases of intracranial aneurysms. Those real cases were obtained by 3D angiography, numerical reconstruction of the geometry, and then pulsatile CFD simulation before post-processing with the mentioned vortex visualization tools. First we tested the two Eulerian methods on a few cases to verify their implementation we made as well as compare them with each other. After that, the Q-criterion was selected as method of choice for its more obvious physical meaning (it shows the balance between two characteristics of the flow, its swirling and deformation). Using iso-surfaces of Q, we started by categorizing the patient-specific aneurysms based on the gross topology of the aneurysmal vortices. This approach being unfruitful, we found a new vortex-based characteristic property of ruptured aneurysms to stratify the rupture risk of IAs that we called the Wall-Kissing Vortices, or WKV. We observed that most ruptured aneurysms had a large amount of WKV, which appears to agree with

  3. Identification of the soluble form of tyrosine kinase receptor Axl as a potential biomarker for intracranial aneurysm rupture.

    Science.gov (United States)

    Xu, Jing; Ma, Feiqiang; Yan, Wei; Qiao, Sen; Xu, Shengquan; Li, Yi; Luo, Jianhong; Zhang, Jianmin; Jin, Jinghua

    2015-03-05

    Subarachnoid hemorrhage caused by a ruptured intracranial aneurysm (RIA) is a devastating condition with significant morbidity and mortality. Despite the fact that RIAs can be prevented by microsurgical clipping or endovascular coiling, there are no reliable means of effectively predicting IA patients at risk for rupture. The purpose of our study was to discover differentially-expressed glycoproteins in IAs with or without rupture as potential biomarkers to predict rupture. Forty age/gender-matched patients with RIA, unruptured IA (UIA), healthy controls (HCs) and disease controls (DCs) (discovery cohort, n = 10 per group) were recruited and a multiplex quantitative proteomic method, iTRAQ (isobaric Tagging for Relative and Absolute protein Quantification), was used to quantify relative changes in the lectin-purified glycoproteins in CSF from RIAs and UIAs compared to HCs and DCs. Then we verified the proteomic results in an independent set of samples (validation cohort, n = 20 per group) by enzyme-linked immunosorbent assay. Finally, we evaluated the specificity and sensitivity of the candidate marker with receiver operating characteristic (ROC) curve methods. The proteomic findings identified 294 proteins, 40 of which displayed quantitative changes unique to RIA, 13 to UIA, and 20 to IA. One of these proteins, receptor tyrosine kinase Axl, was significantly increased in RIA, as confirmed in CSF from the discovery cohort as well as in CSF and plasma from the validation cohort (p IA.

  4. Efficacy of early controlled motion of the ankle compared with no motion after non-operative treatment of an acute Achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Hansen, Maria Swennergren; Hølmich, Per

    2016-01-01

    controlled motion of the ankle in weeks 3-8 after rupture. The control group is immobilized. In total, 130 patients will be included from one big orthopedic center over a period of 2½ years. The primary outcome is the patient-reported Achilles tendon Total Rupture Score evaluated at 12 months post...... affects functional and patient-reported outcomes. METHODS/DESIGN: The study is performed as a blinded, randomized, controlled trial with patients allocated in a 1:1 ratio to one of two parallel groups. Patients aged from 18 to 70 years are eligible for inclusion. The intervention group performs early...... of acute Achilles tendon rupture in a randomized setup. The study uses the patient-reported outcome measure, the Achilles tendon Total Rupture Score, as the primary endpoint, as it is believed to be the best surrogate measure for the tendon's actual capability to function in everyday life. TRIAL...

  5. Spontaneous hepatic rupture in a bodybuilder: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Pietro Mascagni

    Full Text Available ABSTRACT This article is the first description of a spontaneous hepatic rupture in a young bodybuilder with a history of clenbuterol and ephedrine alkaloid use. The patient presented with a sudden mid-epigastric pain and vomiting. Hemoglobin levels decreased a few hours later and a computed tomography scan was performed which revealed a rupture of the right liver capsule and hemoperitoneum. Two attempts at transarterial embolization did not control the bleeding and a right hemihepatectomy was performed. The pathological report identified a hepatic adenoma, a capsular tear and diffuse peliosis hepatis. The patient was discharged in a good condition after eleven days. Spontaneous hepatic ruptures are rare and life-threatening and are usually described in association with tumors, connective tissue diseases and gestosis. This article is a review of the available literature with regard to this condition, with a focus on its relation to peliosis hepatis and banned substance used by body image fanatics. The present case highlights the challenging diagnosis of this potentially fatal liver complication in a healthy appearing male, the risk associated with the online trade of performance enhancing drugs and its relation with peliosis hepatis.

  6. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  7. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    -link capacitance in power electronic converter systems; wind turbine systems; smart control strategies for improved reliability of power electronics system; lifetime modelling; power module lifetime test and state monitoring; tools for performance and reliability analysis of power electronics systems; fault...... for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power...... electronic converter systems; anomaly detection and remaining-life prediction for power electronics; reliability of DC-link capacitors in power electronic converters; reliability of power electronics packaging; modeling for life-time prediction of power semiconductor modules; minimization of DC...

  8. Frequency, predisposing factors and fetomaternal outcome in uterine rupture

    International Nuclear Information System (INIS)

    Malik, H.S.

    2006-01-01

    To determine the frequency and to analyze the predisposing factors, maternal and fetal outcome of uterine rupture. All cases of ruptured uterus, who were either admitted with or who developed this complication in the hospital, were included in the study. Demographic data, details regarding the most probable predisposing factor, type of rupture, the management and maternal and fetal outcome were taken into consideration for analysis.During three years, total number of deliveries was 18668, and there were 103 cases of uterine rupture (0.55%).Out of these, only 13 (12.62%) patients were booked. Most of the patients presented between the ages of 26-30 years (42.71%). Majority of ruptures occurred in para 2-4 (44.66%). Fifty five cases (53.39%) had a previous caesarean section scar. In 68 (66.01%) cases, the tear was located in lower uterine segment. In 93 (90.29%) cases, anterior uterine wall was involved. Rupture was complete in 79 (76.69%)cases. Repair of uterus was done in 79 (76.69%) cases. Hysterectomy was performed in 24 (23.30%) cases. There were 8 (7.76% or 77.66/1000) maternal deaths and 85 (81.73% or 825 / 1000) perinatal deaths.This study confirms high frequency of such serious preventable obstetrical problem which can lead to high fetomaternal mortality. Rupture of caesarean section scar was the most common cause of uterine rupture found in this series. (author)

  9. Source properties of dynamic rupture pulses with off-fault plasticity

    KAUST Repository

    Gabriel, A.-A.

    2013-08-01

    Large dynamic stresses near earthquake rupture fronts may induce an inelastic response of the surrounding materials, leading to increased energy absorption that may affect dynamic rupture. We systematically investigate the effects of off-fault plastic energy dissipation in 2-D in-plane dynamic rupture simulations under velocity-and-state-dependent friction with severe weakening at high slip velocity. We find that plasticity does not alter the nature of the transitions between different rupture styles (decaying versus growing, pulse-like versus crack-like, and subshear versus supershear ruptures) but increases their required background stress and nucleation size. We systematically quantify the effect of amplitude and orientation of background shear stresses on the asymptotic properties of self-similar pulse-like ruptures: peak slip rate, rupture speed, healing front speed, slip gradient, and the relative contribution of plastic strain to seismic moment. Peak slip velocity and rupture speed remain bounded. From fracture mechanics arguments, we derive a nonlinear relation between their limiting values, appropriate also for crack-like and supershear ruptures. At low background stress, plasticity turns self-similar pulses into steady state pulses, for which plastic strain contributes significantly to the seismic moment. We find that the closeness to failure of the background stress state is an adequate predictor of rupture speed for relatively slow events. Our proposed relations between state of stress and earthquake source properties in the presence of off-fault plasticity may contribute to the improved interpretation of earthquake observations and to pseudodynamic source modeling for ground motion prediction.

  10. Traumatic rupture of the aorta

    International Nuclear Information System (INIS)

    Dorfman, G.S.; Paolella, L.P.; Haas, R.A.; Lambiase, R.E.; Cronan, J.J.

    1988-01-01

    To evaluate the acceptability of digital subtraction angiography (DSA) in the evaluation of traumatic rupture of the aorta (TRA), the authors obtained 56 thoracic aortograms in 55 consecutive trauma patients, using both DSA and cut-film angiography (CFA). Both studies were ranked blindly and assigned scores for quality and diagnosis. Interobserver variance for DSA and CFA quality rankings was insignificant. CFA achieved significantly higher ranking for quality. In the 56 examinations, CFA demonstrated seven abnormalities that demanded intervention for follow-up angiography. DSA demonstrated only five of these and found no additional abnormalities. While this evaluation applies only to the particular digital system that the authors tested, they found that DSA, as compared with CFA, failed to demonstrate significant aortic injury. The confidence of diagnosis was significantly greater with CFA. Similar double-blind evaluation is mandatory at any trauma center prior to converting from CFA to DSA in the diagnosis of this life-threatening condition

  11. Misdiagnosed Uterine Rupture of an Advanced Cornual Pregnancy

    Directory of Open Access Journals (Sweden)

    Christian Linus Hastrup Sant

    2012-01-01

    Full Text Available Cornual pregnancy is a diagnostic and therapeutic challenge with potential severe consequences if uterine rupture occurs with following massive intraabdominal bleeding. We report a case of a misdiagnosed ruptured cornual pregnancy occurring at 21 weeks of gestation. Ultrasound examination and computer tomography revealed no sign of abnormal pregnancy. The correct diagnosis was first made at emergency laparotomy. Uterine rupture should be considered in pregnant women presenting with abdominal pain and haemodynamic instability.

  12. Misdiagnosed uterine rupture of an advanced cornual pregnancy

    DEFF Research Database (Denmark)

    Sant, Christian Linus Hastrup; Andersen, Poul Erik

    2012-01-01

    Cornual pregnancy is a diagnostic and therapeutic challenge with potential severe consequences if uterine rupture occurs with following massive intraabdominal bleeding. We report a case of a misdiagnosed ruptured cornual pregnancy occurring at 21 weeks of gestation. Ultrasound examination...... and computer tomography revealed no sign of abnormal pregnancy. The correct diagnosis was first made at emergency laparotomy. Uterine rupture should be considered in pregnant women presenting with abdominal pain and haemodynamic instability....

  13. A study on the reliability evaluation of shot peened aluminium alloy using accelerated life test

    International Nuclear Information System (INIS)

    Nam, Ji Hun; Cheong, Seong Kyun; Kang, Min Woo

    2006-01-01

    In this paper, the concept of accelerated life test, which is a popular research field nowadays, is applied to the shot peened material. To predict the efficient and exact room temperature fatigue characteristics from the high temperature fatigue data, the adequate accelerated model is investigated. Ono type rotary bending fatigue tester and high temperature chamber were used for the experiment. Room temperature fatigue lives were predicted by applying accelerated models and doing reliability evaluation. Room temperature fatigue tests were accomplished to check the effectiveness of predicted data and the adequate accelerated life test models were presented by considering errors. Experimental result using Arrhenius model, fatigue limit obtain almost 5.45% of error, inverse power law has about 1.36% of error, so we found that inverse power law is applied well to temperature-life relative of shot peended material

  14. Spontaneous rupture of choledochal cyst: case report

    International Nuclear Information System (INIS)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young

    2002-01-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued

  15. Spontaneous rupture of choledochal cyst: case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young [Dong-a University College of Medicine, Pusan (Korea, Republic of)

    2002-11-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued.

  16. Ultrasonogram of tubal pregnancy: Unruptured or ruptured?

    International Nuclear Information System (INIS)

    Lee, Hee Jung; Kim, Jung Sik; Lee, Sung Moon; Kim, Hong; Woo, Seong Ku; Yeun, Seong Do; Lee, Doo Ryong

    1993-01-01

    To evaluate the usefulness of ultrasonography in the differentiation of the unruptured ones, we performed prospective ultrasonographic study in 56 patients with tubal pregnancy and subsequently correlated with the surgical (45 cases) and laparoscopic (11 cases) findings. The criterion for unruptured tubal pregnancy was the visualization of extra uterine gestational sac or a mass that was separated from the ipsilateral ovary. All cases were confirmed surgically or laparoscopically within 48 hours after sonographic examination. Forty five (80%)cases were proved as unruptured, tubal pregnancy, while 11 (20%) as ruptured one. Extra uterine gestational sac was seen in 31/45 (69%) in unruptured group and 2/11 (18%) in ruptured group. A mass separated from the ipsilateral ovary was seen in 7 unruptured tubal pregnancies and 2 ruptured pregnancies. A mass that was not separated from the ipsilateral ovary was seen in 13 cases. Seven of these were ruptured pregnancies, while 6 were unrupture dones. Using our criteria, the unruptured tubal pregnancy was diagnosed with a sensitivity of 84%, a specificity of 64%, an accuracy of 80%, a positive predictive value of 90% and a negative predictive value of 50%. We conclude that ultrasonography is useful in the differentiation of the unruptured tubal pregnancy from the ruptured one

  17. Radiologic findings of small bowel rupture due to blunt abdominal trauma

    International Nuclear Information System (INIS)

    Ha, Hyeon Kweun; Bahk, Yong Whee

    1987-01-01

    Bowel rupture due to blunt abdominal trauma is no longer rare, and is among the most challenging problems that confront the physicians and radiologists. It is frequently difficult to diagnose because the symptoms may be trivial during the early stage and masked by more obvious, but less lethal injuries. It is well known that the roentgen examination of the abdomen is also of little value to exclude bowel rupture because of infrequency of positive findings and free gas. The plain films of 23 cases of jejunal rupture and 8 cases of ileal rupture were evaluated to sort and diagnostic features of small bowel rupture caused by blunt abdominal trauma. 1. Free intraperitoneal gas was noted in 6 cases of jejunal rupture (26%) and 1 case of ileal rupture (13%), and definite radiological evidence of free intraperitoneal fluid was present in 16 cases of patients (52%). 2. The contour change of bowel loops such as tapering or indentation were seen in 11 cases of patients (36%), and local opacity along the mesenteric root axis was demonstrated in 19 cases of patients (61%). 3. Paralytic ileus was localized to LUQ in jejunal rupture and to mid-abdomen in ileal rupture, and gastric and transverse-colon distension with gas was noticeable especially in jejunal rupture

  18. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  19. [Development of social activities-related daily life satisfaction scale for the elderly and evaluation of its reliability and validity].

    Science.gov (United States)

    Okamoto, Hideaki

    2010-07-01

    The purpose of this study was to develop a Social Activities-Related Daily Life Satisfaction Scale specifically applicable to elderly people in communities and to evaluate its reliability and validity. Sixteen items were extracted from an initial pool and assessed for inclusion in the scale by correlation and exploratory factor analyses. To confirm validity, confirmatory factor analysis was conducted and correlation coefficients were calculated. In addition, t-tests were performed in order to generate scores of the subscale related to activity. To prove reliability, Cronbach's coefficient alpha values were calculated. Data for 755 older adults aged 65 to 84 years were obtained from a mail survey in Ichikawa City, Chiba Prefecture. Exploratory factor analyses indicated that four factors, "satisfaction with learning" (four items), "satisfaction with usefulness to others and society" (four items), "satisfaction with health and physical strength" (three items), and "satisfaction with friends" (three items) should be extracted. Confirmatory factor analysis for assessing the 14-item four-factor model showed high goodness of fit indices (GFI = 0.943, AGFI = 0.915, RMSEA = 0.068). Concurrent validity was established by comparing the score of the scale with five external variables (Activity and Daily Life Satisfaction Scale for the Elderly, Life Satisfaction Index K, etc). Student's t-tests revealed that each score of the subscale was positively associated with activity variable. The overall Cronbach's coefficient alpha for the scale was 0.919 and for its four subscales values ranged from 0.814 to 0.887. A Social Activities-Related Daily Life Satisfaction Scale was derived consisting of four subscales, "satisfaction with learning", "satisfaction with usefulness to others and society", "satisfaction with health and physical strength", and "satisfaction with friends". The results of the present study suggested that the Social Activities-Related Daily Life Satisfaction Scale

  20. Introduction to quality and reliability engineering

    CERN Document Server

    Jiang, Renyan

    2015-01-01

    This book presents the state-of-the-art in quality and reliability engineering from a product life cycle standpoint. Topics in reliability include reliability models, life data analysis and modeling, design for reliability and accelerated life testing, while topics in quality include design for quality, acceptance sampling and supplier selection, statistical process control, production tests such as screening and burn-in, warranty and maintenance. The book provides comprehensive insights into two closely related subjects, and includes a wealth of examples and problems to enhance reader comprehension and link theory and practice. All numerical examples can be easily solved using Microsoft Excel. The book is intended for senior undergraduate and post-graduate students in related engineering and management programs such as mechanical engineering, manufacturing engineering, industrial engineering and engineering management programs, as well as for researchers and engineers in the quality and reliability fields. D...

  1. Isolated gallbladder rupture following blunt abdominal injury

    African Journals Online (AJOL)

    2015-05-26

    May 26, 2015 ... Kaohsiung Medical University, Kaohsiung, Taiwan. Abstract. Isolated traumatic gallbladder rupture subsequent to blunt abdominal injury is rare. Most literatures on the subjects consist of case reports. We reported a rare case of isolated gallbladder rupture and discussed the possible predisposing factors to ...

  2. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  3. Plantar fascia rupture in a professional soccer player.

    Science.gov (United States)

    Suzue, Naoto; Iwame, Toshiyuki; Kato, Kenji; Takao, Shoichiro; Tateishi, Tomohiko; Takeda, Yoshitsugu; Hamada, Daisuke; Goto, Tomohiro; Takata, Yoichiro; Matsuura, Tetsuya; Sairyo, Koichi

    2014-01-01

    We report the case of a 29-year-old male professional soccer player who presented with symptoms of plantar fasciitis. His symptoms occurred with no remarkable triggers and gradually worsened despite conservative treatments including taping, use of insoles, and physical therapy. Local corticosteroid injection was given twice as a further intervention, but his plantar fascia partially ruptured 49 days after the second injection. He was treated conservatively with platelet-rich plasma, and magnetic resonance imaging showed regenerative change of the ruptured fascia. Five months after the rupture, he returned to his original level of training. If professional athletes find it difficult to refrain from athletic activity, as in the present case, the risk of rupture due to corticosteroid injection should not be overlooked.

  4. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  5. Traumatic rupture of the diaphragm: CT findings

    International Nuclear Information System (INIS)

    Cho, Sung Tae; Kim, Sung Jin; Cha, Sang Hoon; Park, Kil Sun; Kim, Jin Hee; Yim, Se Hwan

    1995-01-01

    The aim of this study was to assess the clinical utility of the known CT signs of the traumatic rupture of the diaphragm. CT scans and chest radiographs were retrospectively reviewed in 13 patients who had diaphragmatic rupture confirmed by surgery. On chest radiographs the elevation of the diaphragm was evaluated. On CT, 1) discontinuity of the diaphragm, 2) lack of depiction of the diaphragm surrounding the herniated intraabdominal organs (absent diaphragm sign), and 3) fat seen lateral to the diaphragm (fat sign) were evaluated. Chest radiographs showed the elevation of the diaphragm in 11 patients (85%). CT scan showed absent diaphragm sign in 11 patients (85%), discontinuity of the diaphragm in 8 (62%), and fat sign in 7 (54%). All of 12 patients who had the left diaphragmatic rupture had one or more of the above findings. Discontinuity of the diaphragm, absent diaphragm sign, and fat sign may be helpful CT findings in the diagnosis of the traumatic rupture of the left diaphragm

  6. Traumatic Gallbladder Rupture Treated by Laparoscopic Cholecystectomy

    Science.gov (United States)

    Egawa, Noriyuki; Ueda, Junji; Hiraki, Masatsugu; Ide, Takao; Inoue, Satoshi; Sakamoto, Yuichiro; Noshiro, Hirokazu

    2016-01-01

    Abstract Gallbladder rupture due to blunt abdominal injury is rare. There are few reports of traumatic gallbladder injury, and it is commonly associated with other concomitant visceral injuries. Therefore, it is difficult to diagnose traumatic gallbladder rupture preoperatively when it is caused by blunt abdominal injury. We report a patient who underwent laparoscopic cholecystectomy after an exact preoperative diagnosis of traumatic gallbladder rupture. A 43-year-old man was admitted to our hospital due to blunt abdominal trauma. The day after admission, abdominal pain and ascites increased and a muscular defense sign appeared. Percutaneous drainage of the ascites was performed, and the aspirated fluid was bloody and almost pure bile. He was diagnosed with gallbladder rupture by the cholangiography using the endoscopic retrograde cholangiopancreatography technique. Laparoscopic cholecystectomy was performed safely, and he promptly recovered. If accumulated fluids contain bile, endoscopic cholangiography is useful not only to diagnose gallbladder injury but also to determine the therapeutic strategy. PMID:27462188

  7. Traumatic Gallbladder Rupture Treated by Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Noriyuki Egawa

    2016-05-01

    Full Text Available Gallbladder rupture due to blunt abdominal injury is rare. There are few reports of traumatic gallbladder injury, and it is commonly associated with other concomitant visceral injuries. Therefore, it is difficult to diagnose traumatic gallbladder rupture preoperatively when it is caused by blunt abdominal injury. We report a patient who underwent laparoscopic cholecystectomy after an exact preoperative diagnosis of traumatic gallbladder rupture. A 43-year-old man was admitted to our hospital due to blunt abdominal trauma. The day after admission, abdominal pain and ascites increased and a muscular defense sign appeared. Percutaneous drainage of the ascites was performed, and the aspirated fluid was bloody and almost pure bile. He was diagnosed with gallbladder rupture by the cholangiography using the endoscopic retrograde cholangiopancreatography technique. Laparoscopic cholecystectomy was performed safely, and he promptly recovered. If accumulated fluids contain bile, endoscopic cholangiography is useful not only to diagnose gallbladder injury but also to determine the therapeutic strategy.

  8. Improving machinery reliability

    CERN Document Server

    Bloch, Heinz P

    1998-01-01

    This totally revised, updated and expanded edition provides proven techniques and procedures that extend machinery life, reduce maintenance costs, and achieve optimum machinery reliability. This essential text clearly describes the reliability improvement and failure avoidance steps practiced by best-of-class process plants in the U.S. and Europe.

  9. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  10. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  11. Development of a computer model to predict aortic rupture due to impact loading.

    Science.gov (United States)

    Shah, C S; Yang, K H; Hardy, W; Wang, H K; King, A I

    2001-11-01

    Aortic injuries during blunt thoracic impacts can lead to life threatening hemorrhagic shock and potential exsanguination. Experimental approaches designed to study the mechanism of aortic rupture such as the testing of cadavers is not only expensive and time consuming, but has also been relatively unsuccessful. The objective of this study was to develop a computer model and to use it to predict modes of loading that are most likely to produce aortic ruptures. Previously, a 3D finite element model of the human thorax was developed and validated against data obtained from lateral pendulum tests. The model included a detailed description of the heart, lungs, rib cage, sternum, spine, diaphragm, major blood vessels and intercostal muscles. However, the aorta was modeled as a hollow tube using shell elements with no fluid within, and its material properties were assumed to be linear and isotropic. In this study fluid elements representing blood have been incorporated into the model in order to simulate pressure changes inside the aorta due to impact. The current model was globally validated against experimental data published in the literature for both frontal and lateral pendulum impact tests. Simulations of the validated model for thoracic impacts from a number of directions indicate that the ligamentum arteriosum, subclavian artery, parietal pleura and pressure changes within the aorta are factors that could influence aortic rupture. The model suggests that a right-sided impact to the chest is potentially more hazardous with respect to aortic rupture than any other impact direction simulated in this study. The aortic isthmus was the most likely site of aortic rupture regardless of impact direction. The reader is cautioned that this model could only be validated on a global scale. Validation of the kinematics and dynamics of the aorta at the local level could not be done due to a lack of experimental data. It is hoped that this model will be used to design

  12. Validity and reliability of the Portuguese version of the quality of life in epilepsy inventory (QOLIE-31) for Brazil.

    Science.gov (United States)

    da Silva, Tatiana Indelicato; Ciconelli, Rozana Mesquita; Alonso, Neide Barreira; Azevedo, Auro Mauro; Westphal-Guitti, Ana Carolina; Pascalicchio, Tatiana Frascarelli; Marques, Carolina Mattos; Caboclo, Luís Otávio Sales Ferreira; Cramer, Joyce A; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2007-03-01

    We report the cultural adaptation and psychometric properties of the Quality of Life in Epilepsy-31 Inventory (QOLIE-31) for the Portuguese language and Brazilian culture. This study involved 150 outpatients: 50 presurgical patients with refractory temporal lobe epilepsy (TLE) related to mesial temporal sclerosis (MTS), 50 patients with juvenile myoclonic epilepsy (JME), and 50 seizure-free patients with TLE. They completed the QOLIE-31, Nottingham Health Profile (NHP), Beck Depression Inventory (BDI), and Adverse Events Profile (AEP) and underwent a neuropsychological evaluation (NE). Internal consistency reliability, interrater and test-retest reliability, and construct validity were assessed. QOLIE-31 mean scores were 33.1 (Social Function), 68.9 (Overall Quality of Life), 56.5 (Seizure Worry), 64.1 (Emotional Well-Being), 63.7 (Energy/Fatigue), 38.9 (Cognitive Function), and 49.7 (Medication Effects). Internal consistency was high (Cronbach's alpha), as were the associations between QOLIE-31 and the BDI, NHP, AEP, and NE. The Portuguese/Brazilian version of the QOLIE-31 inventory showed good reliability, validity, and construct validity.

  13. Surface rupture and vertical deformation associated with 20 May 2016 M6 Petermann Ranges earthquake, Northern Territory, Australia

    Science.gov (United States)

    Gold, Ryan; Clark, Dan; King, Tamarah; Quigley, Mark

    2017-04-01

    Surface-rupturing earthquakes in stable continental regions (SCRs) occur infrequently, though when they occur in heavily populated regions the damage and loss of life can be severe (e.g., 2001 Bhuj earthquake). Quantifying the surface-rupture characteristics of these low-probability events is therefore important, both to improve understanding of the on- and off-fault deformation field near the rupture trace and to provide additional constraints on earthquake magnitude to rupture length and displacement, which are critical inputs for seismic hazard calculations. This investigation focuses on the 24 August 2016 M6.0 Petermann Ranges earthquake, Northern Territory, Australia. We use 0.3-0.5 m high-resolution optical Worldview satellite imagery to map the trace of the surface rupture associated with the earthquake. From our mapping, we are able to trace the rupture over a length of 20 km, trending NW, and exhibiting apparent north-side-up motion. To quantify the magnitude of vertical surface deformation, we use stereo Worldview images processed using NASA Ames Stereo Pipeline software to generate pre- and post-earthquake digital terrain models with a spatial resolution of 1.5 to 2 m. The surface scarp is apparent in much of the post-event digital terrain model. Initial efforts to difference the pre- and post-event digital terrain models yield noisy results, though we detect vertical deformation of 0.2 to 0.6 m over length scales of 100 m to 1 km from the mapped trace of the rupture. Ongoing efforts to remove ramps and perform spatial smoothing will improve our understanding of the extent and pattern of vertical deformation. Additionally, we will compare our results with InSAR and field measurements obtained following the earthquake.

  14. CT classification and clinical significance of rupture globe

    International Nuclear Information System (INIS)

    Diao Jinzhong; Zhang Guixiang

    1998-01-01

    Purpose: To discuss CT appearances of the rupture globe, and CT classifications and their clinical significance. Materials and methods: Forty-nine rupture globes were verified; 79% patents were scanned within 24 hours. Axial plane scanning were done with 3 mm slice and 256 x 256 matrix. Bone and soft tissue conditions were adjusted to analyse the bone and globe structures. Results: CT showed that globe circle rupture in one point of 32%, two points of 20%, and multiple points of 28%. Thickening of globe circle was as follows: 5 mm in 10 globes, 6 mm in 24, and 7 mm in 9.20% injured globes were enlarged and 32% were contracted. 14 anterior chambers deepened more than 4 mm. 83% rupture globes also had intraglobe hemorrhage and 48% foreign bodies. 28% injured globes had exophthalmus, and 75% had injured parasinuses or orbits, or brain trauma. Conclusion: The authors classified the rupture globe into three types. Type III showed unrepaired that should ablate the injured globes, whereas type I and II had to repair and to debride

  15. Ruptured Massa Intermedia Secondary to Hydrocephalus.

    Science.gov (United States)

    El Damaty, Ahmed; Langner, Soenke; Schroeder, Henry W S

    2017-01-01

    We report a case of ruptured massa intermedia (MI) as a sequela of hydrocephalus. A single case report is presented describing the sequelae of tumor bed hematoma after a posterior fossa hemangioblastoma resection in which the patient bled 3 days after surgery, resulting in secondary hydrocephalus and subsequently dilatation of the third ventricle, which resulted in rupture of the MI. The patient was managed on emergency basis with an external ventricular drain then endoscopically with a third ventriculostomy and clot extraction. Absent MI is not uncommon in hydrocephalic patients, and it is assumed to be the result of rupture from acute dilatation of the third ventricle. Our case report proves this assumption and documents the presence and absence of the MI before and after developing hydrocephalus. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A comparison of pre-dropout and temporary rupture sessions in psychotherapy.

    Science.gov (United States)

    Gülüm, I Volkan; Soygüt, Gonca; Safran, Jeremy D

    2016-11-15

    Although numerous studies have investigated the relationship between the therapeutic alliance and dropout, most have focused on the relationship between alliance quality and psychotherapy outcomes. To compare sessions with therapeutic alliance ruptures and two sessions prior to treatment dropout (pre-dropout) in terms of rupture subtypes, psychotherapists' behavior, attitudes, and session content. We implemented quantitative methods to select the sessions and qualitative methods to analyze them. We analyzed 16 temporary rupture sessions from 12 therapist-patient dyads and 16 pre-dropout sessions from 8 different therapist-patient dyads. The sessions originate from clinical psychology Master's or Doctoral students under supervision in either cognitive behavioral or schema therapy. Pre-dropout sessions were considered unrepaired rupture sessions while rupture sessions were subsequently repaired. Results revealed apparent differences and similarities between the session types in positive and negative psychotherapist behaviors, content intensity, and the type and frequency of ruptures. We explored three new rupture subtypes: attributing positive developments to other sources, indirect speech, and sarcastic hostility. A striking implication is that the frequency of positive and negative psychotherapist behaviors, ruptures, and session content is more likely to decrease in the pre-dropout sessions than in the temporary rupture sessions.

  17. Double rupture disc experience

    International Nuclear Information System (INIS)

    1979-01-01

    Result of these observations, comparisons and evaluations can be summarized in the following list of concerns regarding the use of double rupture discs coupled to the liquid space of a steam generator that is subjected to a large leak sodium water reaction event. Single rupture disc show delayed collapse characteristics in LLTR Series I and double disc assemblies are presumed to be more complex with additional delay before opening to give pressure relief. Delayed failure increases pressures in the IHTS and must be adequately covered by design requirements. With CRBR design, the first disc may fail only partially reducing the loading on the second disc with the result that relief performance may not meet requirements

  18. Non‑bleeding Spontaneous Rupture of Hepatocellular Carcinoma

    African Journals Online (AJOL)

    split easily when the vascular load increases from hypertension or minor trauma is another hypothesis for of HCC ruptures.[6]. Abdominal pain is the only independent factor relating to rupture of HCC.[7] Doppler ultrasound and computer tomography (CT) scan are useful to exclude of hemoperitoneum and evaluation.

  19. Fault Branching and Long-Term Earthquake Rupture Scenario for Strike-Slip Earthquake

    Science.gov (United States)

    Klinger, Y.; CHOI, J. H.; Vallage, A.

    2017-12-01

    Careful examination of surface rupture for large continental strike-slip earthquakes reveals that for the majority of earthquakes, at least one major branch is involved in the rupture pattern. Often, branching might be either related to the location of the epicenter or located toward the end of the rupture, and possibly related to the stopping of the rupture. In this work, we examine large continental earthquakes that show significant branches at different scales and for which ground surface rupture has been mapped in great details. In each case, rupture conditions are described, including dynamic parameters, past earthquakes history, and regional stress orientation, to see if the dynamic stress field would a priori favor branching. In one case we show that rupture propagation and branching are directly impacted by preexisting geological structures. These structures serve as pathways for the rupture attempting to propagate out of its shear plane. At larger scale, we show that in some cases, rupturing a branch might be systematic, hampering possibilities for the development of a larger seismic rupture. Long-term geomorphology hints at the existence of a strong asperity in the zone where the rupture branched off the main fault. There, no evidence of throughgoing rupture could be seen along the main fault, while the branch is well connected to the main fault. This set of observations suggests that for specific configurations, some rupture scenarios involving systematic branching are more likely than others.

  20. Pancreatic Pseudocyst Ruptured due to Acute Intracystic Hemorrhage

    Directory of Open Access Journals (Sweden)

    Kunishige Okamura

    2017-12-01

    Full Text Available Rupture of pancreatic pseudocyst is one of the rare complications and usually results in high mortality. The present case was a rupture of pancreatic pseudocyst that could be treated by surgical intervention. A 74-year-old man developed abdominal pain, vomiting, and diarrhea, and he was diagnosed with cholecystitis and pneumonia. Three days later, acute pancreatitis occurred and computed tomography (CT showed slight hemorrhage in the cyst of the pancreatic tail. After another 10 days, CT showed pancreatic cyst ruptured due to intracystic hemorrhage. Endoscopic retrograde cholangiopancreatography revealed leakage of contrast agent from pancreatic tail cyst to enclosed abdominal cavity. His left hypochondrial pain was increasing, and CT showed rupture of the cyst of the pancreatic tail into the peritoneal cavity was increased in 10 days. CT showed also two left renal tumors. Therefore we performed distal pancreatectomy with concomitant resection of transverse colon and left kidney. We histopathologically diagnosed pancreatic pseudocyst ruptured due to intracystic hemorrhage and renal cell carcinoma. Despite postoperative paralytic ileus and fluid collection at pancreatic stump, they improved by conservative management and he could be discharged on postoperative day 29. He has achieved relapse-free survival for 6 months postoperatively. The mortality of pancreatic pseudocyst rupture is very high if some effective medical interventions cannot be performed. It should be necessary to plan appropriate treatment strategy depending on each patient.

  1. Steam generator tube rupture effects on a LOCA

    International Nuclear Information System (INIS)

    LaChance, J.L.

    1979-01-01

    A problem currently experienced in commercial operating pressurized water reactors (PWR) in the United States is the degradation of steam generator tubes. Safety questions have arisen concerning the effect of these degraded tubes rupturing during a postulated loss-of-coolant accident (LOCA). To determine the effect of a small number of tube ruptures on the behavior of a large PWR during a postulated LOCA, a series of computer simulations was performed. The primary concern of the study was to determine whether a small number (10 or less of steam generator tubes rupturing at the beginning surface temperatures. Additional reflood analyses were performed to determine the system behavior when from 10 to 60 tubes rupture at the beginning of core reflood. The FLOOD4 code was selected as being the most applicable code for use in this study after an extensive analysis of the capabilities of existing codes to perform simulations of a LOCA with concurrent steam generator tube ruptures. The results of the study indicate that the rupturing of 10 or less steam generator tubes in any of the steam generators during a 200% cold leg break will not result in a significant increase in the peak cladding temperature. However, because of the vaporization of the steam generator secondary water in the primary side of the steam generator, a significant increase in the core pressure occurs which retards the reflooding process

  2. Vascular type Ehlers-Danlos Syndrome with fatal spontaneous rupture of a right common iliac artery dissection: case report and review of literature

    Science.gov (United States)

    Abayazeed, Aly; Hayman, Emily; Moghadamfalahi, Mana; Cain, Darren

    2014-01-01

    Vascular Ehlers-Danlos Syndrome (previously Ehlers-Danlos IV) is a rare autosomal dominant collagen vascular disorder caused by a 2q31 COL3A1 gene mutation encoding pro-alpha1 chain of type III collagen (in contrast to classic Ehlers-Danlos, caused by a COL5A1 mutation). The vascular type accounts for less than 4% of all Ehlers-Danlos cases and usually has a poor prognosis due to life threatening vascular ruptures and difficult, frequently unsuccessful surgical and vascular interventions. In 70% of cases, vascular rupture or dissection, gastrointestinal perforation, or organ rupture is a presenting sign. We present a case of genetically proven vascular Ehlers-Danlos with fatal recurrent retroperitoneal hemorrhages secondary to a ruptured right common iliac artery dissection in a 30-year-old male. This case highlights the need to suspect collagen vascular disorders when a young adult presents with unexplained retroperitoneal hemorrhage, even without family history of such diseases. PMID:24967021

  3. The rupture process of the Manjil, Iran earthquake of 20 june 1990 and implications for intraplate strike-slip earthquakes

    Science.gov (United States)

    Choy, G.L.; Zednik, J.

    1997-01-01

    In terms of seismically radiated energy or moment release, the earthquake of 20 January 1990 in the Manjil Basin-Alborz Mountain region of Iran is the second largest strike-slip earthquake to have occurred in an intracontinental setting in the past decade. It caused enormous loss of life and the virtual destruction of several cities. Despite a very large meizoseismal area, the identification of the causative faults has been hampered by the lack of reliable earthquake locations and conflicting field reports of surface displacement. Using broadband data from global networks of digitally recording seismographs, we analyse broadband seismic waveforms to derive characteristics of the rupture process. Complexities in waveforms generated by the earthquake indicate that the main shock consisted of a tiny precursory subevent followed in the next 20 seconds by a series of four major subevents with depths ranging from 10 to 15 km. The focal mechanisms of the major subevents, which are predominantly strike-slip, have a common nodal plane striking about 285??-295??. Based on the coincidence of this strike with the dominant tectonic fabric of the region we presume that the EW striking planes are the fault planes. The first major subevent nucleated slightly south of the initial precursor. The second subevent occurred northwest of the initial precursor. The last two subevents moved progressively southeastward of the first subevent in a direction collinear with the predominant strike of the fault planes. The offsets in the relative locations and the temporal delays of the rupture subevents indicate heterogeneous distribution of fracture strength and the involvement of multiple faults. The spatial distribution of teleseismic aftershocks, which at first appears uncorrelated with meizoseismal contours, can be decomposed into stages. The initial activity, being within and on the periphery of the rupture zone, correlates in shape and length with meizoseismal lines. In the second stage

  4. Eccentric pressurized tube for measuring creep rupture

    International Nuclear Information System (INIS)

    Schwab, P.R.

    1981-01-01

    Creep rupture is a long term failure mode in structural materials that occurs at high temperatures and moderate stress levels. The deterioration of the material preceding rupture, termed creep damage, manifests itself in the formation of small cavities on grain boundaries. To measure creep damage, sometimes uniaxial tests are performed, sometimes density measurements are made, and sometimes the grain boundary cavities are measured by microscopy techniques. The purpose of the present research is to explore a new method of measuring creep rupture, which involves measuring the curvature of eccentric pressurized tubes. Theoretical investigations as well as the design, construction, and operation of an experimental apparatus are included in this research

  5. Analysis of Communication between Main Control Room Operators in Decision-making Process in Steam Generator Tube Rupture Accident

    International Nuclear Information System (INIS)

    Petkov, M.; Petkov, G.

    2006-01-01

    The paper presents an investigation results for Main Control Room operators' reliability by Performance Evaluation of Teamwork method, based on FSS-1000 training archives in KNPP in case of Steam Generator Tube Rupture accident. The advantages of operators' teamwork are shown: a) group decision-making vs. individual one: b) positive influence of crew initiated communication consisting of orders and reports that are required by instruction. (authors)

  6. Crystal plastic earthquakes in dolostones: from slow to fast ruptures.

    Science.gov (United States)

    Passelegue, F. X.; Aubry, J.; Nicolas, A.; Fondriest, M.; Schubnel, A.; Di Toro, G.

    2017-12-01

    Dolostone is the most dominant lithology of the seismogenic upper crust around the Mediterranean Sea. Understanding the internal mechanisms controlling fault friction is crucial for understanding seismicity along active faults. Displacement in such fault zones is frequently highlighted by highly reflective (mirror-like) slip surfaces, created by thin films of nanogranular fault rock. Using saw-cut dolostone samples coming from natural fault zones, we conducted stick-slip experiments under triaxial loading conditions at 30, 60 and 90 MPa confining pressure and temperature ranging from 30 to 100 degrees C. At 30 and 65 degrees C, only slow rupture was observed and the experimental fault exhibits frictional behaviour, i.e. a dependence of normal stress on peak shear stress. At 65 degrees C, a strengthening behaviour is observed after the main rupture, leading to a succession of slow rupture. At 100 degrees C, the macroscopic behaviour of the fault becomes ductile, and no dependence of pressure on the peak shear stress is observed. In addition, the increase of the confining pressure up to 60 and 90 MPa allow the transition from slow to fast rupture, highlighted by the records of acoustic activity and by dynamic stress drop occurring in a few tens of microseconds. Using strain gages located along the fault surface and acoustic transducers, we were able to measure the rupture velocities during slow and fast rupture. Slow ruptures propagated around 0.1 m/s, in agreement with natural observations. Fast ruptures propagated up to supershear velocities, i.e. faster than the shear wave speed (>3500 m/s). A complete study of the microstructures was realized before and after ruptures. Slow ruptures lead to the production of mirror-like surface driven by the production of nanograins due to dislocation processes. Fast ruptures induce the production of amorphous material along the fault surface, which may come from decarbonation and melting processes. We demonstrate that the

  7. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    Science.gov (United States)

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Modelling ground rupture due to groundwater withdrawal: applications to test cases in China and Mexico

    Science.gov (United States)

    Franceschini, A.; Teatini, P.; Janna, C.; Ferronato, M.; Gambolati, G.; Ye, S.; Carreón-Freyre, D.

    2015-11-01

    The stress variation induced by aquifer overdraft in sedimentary basins with shallow bedrock may cause rupture in the form of pre-existing fault activation or earth fissure generation. The process is causing major detrimental effects on a many areas in China and Mexico. Ruptures yield discontinuity in both displacement and stress field that classic continuous finite element (FE) models cannot address. Interface finite elements (IE), typically used in contact mechanics, may be of great help and are implemented herein to simulate the fault geomechanical behaviour. Two main approaches, i.e. Penalty and Lagrangian, are developed to enforce the contact condition on the element interface. The incorporation of IE incorporation into a three-dimensional (3-D) FE geomechanical simulator shows that the Lagrangian approach is numerically more robust and stable than the Penalty, thus providing more reliable solutions. Furthermore, the use of a Newton-Raphson scheme to deal with the non-linear elasto-plastic fault behaviour allows for quadratic convergence. The FE - IE model is applied to investigate the likely ground rupture in realistic 3-D geologic settings. The case studies are representative of the City of Wuxi in the Jiangsu Province (China), and of the City of Queretaro, Mexico, where significant land subsidence has been accompanied by the generation of several earth fissures jeopardizing the stability and integrity of the overland structures and infrastructure.

  9. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  10. The influence of Boron on creep-rupture behaviour of austenitic unstabilized and Nb-stabilized stainless steel X8CrNi 1613 in unirradiated and irradiated condition

    International Nuclear Information System (INIS)

    Sen, Susant Kumar.

    1976-10-01

    The present study deals with influence of boron on creep-rupture behaviour in unirradiated condition at 650 0 C along with precipitation behaviour, heat-treatment and recrystallization of unstabilized and stabilized steel. The results of creep-rupture tests on unirradiated specimens show that boron exerts a beneficial effect on the rupture life and ductility. Boron losses its beneficial effect on creep properties in unstabilized steel by prolong creeping. The magnitude of beneficial effect of Boron on creep properties depends upon the initial boron distribution which influences the number, size and distribution of the precipitates. Boron promotes the precipitation of type M 23 C 6 Carbides in the grain as well as at the grain boundary. Boron segregates in atomic form during slow cooling from austenitizing temperature. The recrystallization will be delayed by the presence of boron. The results of creep tests at 650 0 C shows that boron exerts a beneficial effect on creep life of irradiated steels. (orig./GSC) [de

  11. Rupture Complexity Promoted by Damaged Fault Zones in Earthquake Cycle Models

    Science.gov (United States)

    Idini, B.; Ampuero, J. P.

    2017-12-01

    Pulse-like ruptures tend to be more sensitive to stress heterogeneity than crack-like ones. For instance, a stress-barrier can more easily stop the propagation of a pulse than that of a crack. While crack-like ruptures tend to homogenize the stress field within their rupture area, pulse-like ruptures develop heterogeneous stress fields. This feature of pulse-like ruptures can potentially lead to complex seismicity with a wide range of magnitudes akin to the Gutenberg-Richter law. Previous models required a friction law with severe velocity-weakening to develop pulses and complex seismicity. Recent dynamic rupture simulations show that the presence of a damaged zone around a fault can induce pulse-like rupture, even under a simple slip-weakening friction law, although the mechanism depends strongly on initial stress conditions. Here we aim at testing if fault zone damage is a sufficient ingredient to generate complex seismicity. In particular, we investigate the effects of damaged fault zones on the emergence and sustainability of pulse-like ruptures throughout multiple earthquake cycles, regardless of initial conditions. We consider a fault bisecting a homogeneous low-rigidity layer (the damaged zone) embedded in an intact medium. We conduct a series of earthquake cycle simulations to investigate the effects of two fault zone properties: damage level D and thickness H. The simulations are based on classical rate-and-state friction, the quasi-dynamic approximation and the software QDYN (https://github.com/ydluo/qdyn). Selected fully-dynamic simulations are also performed with a spectral element method. Our numerical results show the development of complex rupture patterns in some damaged fault configurations, including events of different sizes, as well as pulse-like, multi-pulse and hybrid pulse-crack ruptures. We further apply elasto-static theory to assess how D and H affect ruptures with constant stress drop, in particular the flatness of their slip profile

  12. Long-term outcomes of percutaneous lumbar facet synovial cyst rupture

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Bos, Stijn A.; Torriani, Martin; Simeone, F.J.; Chang, Connie Y.; Pomerantz, Stuart R.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-01-15

    To evaluate the therapeutic value, safety, and long-term clinical outcomes of percutaneous lumbar facet synovial cyst (LFSC) rupture. Our study was institutional review board (IRB)-approved and Health Insurance Portability and Accountability Act (HIPAA)-compliant. The study group comprised 71 patients (44 women, mean age: 65 ± 17 years) who underwent CT- or fluoroscopy-guided percutaneous LFSC rupture. The technical success of LFSC rupture, the long-term clinical outcome, including repeat procedures or surgery, and imaging findings on MRI and CT were recorded. Seventy-nine LFSC ruptures were performed in 71 patients. CT guidance was used in 57 cases and fluoroscopy guidance in 22 cases. LFSC rupture was technically successful in 58 out of 79 cases (73 %). Mean injection volume for cyst rupture was 3.6 ± 2.2 mL and a combination of steroid and anesthetic was injected in all cases. Over a mean follow-up time of 44 months, 12 % of patients underwent repeat cyst rupture, and 46 % eventually underwent surgery, whereas the majority of patients (55 %) experienced symptomatic relief and did not undergo surgery. There was no significant association between a successful outcome and age, sex, level, or size of LFSC (p > 0.1). LFSCs with T2 hypointensity were more likely to require surgery (p = 0.02). There was one complication, a bacterial skin infection that completely resolved following antibiotic therapy. Percutaneous LFSC rupture is an effective and safe nonsurgical treatment option for LFSC. More than half of treated patients were able to avoid subsequent surgery. Therefore, percutaneous LFSC rupture should be considered before surgical intervention. (orig.)

  13. A support-operator method for 3-D rupture dynamics

    Science.gov (United States)

    Ely, Geoffrey P.; Day, Steven M.; Minster, Jean-Bernard

    2009-06-01

    We present a numerical method to simulate spontaneous shear crack propagation within a heterogeneous, 3-D, viscoelastic medium. Wave motions are computed on a logically rectangular hexahedral mesh, using the generalized finite-difference method of Support Operators (SOM). This approach enables modelling of non-planar surfaces and non-planar fault ruptures. Our implementation, the Support Operator Rupture Dynamics (SORD) code, is highly scalable, enabling large-scale, multiprocessors calculations. The fault surface is modelled by coupled double nodes, where rupture occurs as dictated by the local stress conditions and a frictional failure law. The method successfully performs test problems developed for the Southern California Earthquake Center (SCEC)/U.S. Geological Survey (USGS) dynamic earthquake rupture code validation exercise, showing good agreement with semi-analytical boundary integral method results. We undertake further dynamic rupture tests to quantify numerical errors introduced by shear deformations to the hexahedral mesh. We generate a family of meshes distorted by simple shearing, in the along-strike direction, up to a maximum of 73°. For SCEC/USGS validation problem number 3, grid-induced errors increase with mesh shear angle, with the logarithm of error approximately proportional to angle over the range tested. At 73°, rms misfits are about 10 per cent for peak slip rate, and 0.5 per cent for both rupture time and total slip, indicating that the method (which, up to now, we have applied mainly to near-vertical strike-slip faulting) is also capable of handling geometries appropriate to low-angle surface-rupturing thrust earthquakes. Additionally, we demonstrate non-planar rupture effects, by modifying the test geometry to include, respectively, cylindrical curvature and sharp kinks.

  14. Safety design guide for pipe rupture protection for CANDU 9

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new

  15. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  16. Laparoscopic splenectomy for spontaneous rupture of the spleen

    Directory of Open Access Journals (Sweden)

    Pinky M Thapar

    2016-01-01

    Full Text Available Laparoscopic splenectomy is a gold standard for management of planned benign splenic pathologies. Spontaneous rupture of the spleen (SRS leading to acute abdomen occurs in only 1% of all splenic ruptures. Laparoscopic splenectomy in traumatic and atraumatic rupture due to intra-splenic pathology is reported. We present the first reported case of laparoscopic splenectomy in a 23-year-old male who presented with hemoperitoneum due to idiopathic or SRS. The procedure was safely accomplished with slight modified technique and minimum usage of advanced gadgets.

  17. Endovascular Aneurysm Repair Using a Reverse Chimney Technique in a Patient With Marfan Syndrome and Contained Ruptured Chronic Type B Dissection

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Kalender, Guenay; Heuschmid, Martin; Syha, Roland; Mangold, Stefanie; Claussen, Claus D.; Brechtel, Klaus

    2011-01-01

    We report endovascular thoracic and abdominal aneurysm repair (EVAR) with reverse chimney technique in a patient with contained ruptured type B dissection. EVAR seems feasible as a bailout option in Marfan patients with acute life-threatening disease.

  18. Size ratio correlates with intracranial aneurysm rupture status: a prospective study.

    Science.gov (United States)

    Rahman, Maryam; Smietana, Janel; Hauck, Erik; Hoh, Brian; Hopkins, Nick; Siddiqui, Adnan; Levy, Elad I; Meng, Hui; Mocco, J

    2010-05-01

    The prediction of intracranial aneurysm (IA) rupture risk has generated significant controversy. The findings of the International Study of Unruptured Intracranial Aneurysms (ISUIA) that small anterior circulation aneurysms (IAs are small. These discrepancies have led to the search for better aneurysm parameters to predict rupture. We previously reported that size ratio (SR), IA size divided by parent vessel diameter, correlated strongly with IA rupture status (ruptured versus unruptured). These data were all collected retrospectively off 3-dimensional angiographic images. Therefore, we performed a blinded prospective collection and evaluation of SR data from 2-dimensional angiographic images for a consecutive series of patients with ruptured and unruptured IAs. We prospectively enrolled 40 consecutive patients presenting to a single institution with either ruptured IA or for first-time evaluation of an incidental IA. Blinded technologists acquired all measurements from 2-dimensional angiographic images. Aneurysm rupture status, location, IA maximum size, and parent vessel diameter were documented. The SR was calculated by dividing the aneurysm size (mm) by the average parent vessel size (mm). A 2-tailed Mann-Whitney test was performed to assess statistical significance between ruptured and unruptured groups. Fisher exact test was used to compare medical comorbidities between the ruptured and unruptured groups. Significant differences between the 2 groups were subsequently tested with logistic regression. SE and probability values are reported. Forty consecutive patients with 24 unruptured and 16 ruptured aneurysms met the inclusion criteria. No significant differences were found in age, gender, smoking status, or medical comorbidities between ruptured and unruptured groups. The average maximum size of the unruptured IAs (6.18 + or - 0.60 mm) was significantly smaller compared with the ruptured IAs (7.91 + or - 0.47 mm; P=0.03), and the unruptured group had

  19. Resolution of alliance ruptures: The special case of animal-assisted psychotherapy.

    Science.gov (United States)

    Zilcha-Mano, Sigal

    2017-01-01

    Many therapists regard alliance ruptures as one of the greatest challenges therapists face in the therapy room. Alliance ruptures has been previously defined as breakdowns in the process of negotiation of treatment tasks and goals and a deterioration in the affective bond between patient and therapist. Alliance ruptures have been found to predict premature termination of treatment and poor treatment outcomes. But ruptures can also present important opportunities for gaining insight and awareness and for facilitating therapeutic change. A process of rupture resolution may lead to beneficial outcomes and serve as a corrective emotional experience. The article describes unique processes of alliance rupture resolution inherent in animal-assisted psychotherapy (AAP). Building on Safran and Muran's model and on clinical examples, the article describes strategies for identifying ruptures in AAP and techniques for repairing them to facilitate a corrective experience in treatment. Implications for clinical practice and future research are discussed.

  20. End-stage dementia spark of life: reliability and validity of the "GATOS" questionnaire.

    Science.gov (United States)

    Tsoucalas, Gregory; Bourelia, Stamati; Kalogirou, Vaso; Giatsiou, Styliani; Mavrogiannaki, Eirini; Gatos, Georgios; Galanos, Antonis; Repana, Olga; Iliadou, Eleni; Antoniou, Antonis; Sgantzos, Markos; Gatos, Konstantinos

    2015-01-01

    Fl oor effects are present in most dementia assessment tools as dementia progresses and the in-depth assessment of patients considered more or less on vegetative state is questionable. To develop a questionnaire (the "Gatos Clinical Test-GCT") for the assessment of end-stage demented patients. Five hundred patients with dementia of various causes and an MMSE score between 0 and 2 were enrolled in the study. The GCT consists of 14 closed type questions rated on a Likert scale. The total score is used to evaluate patient's dementia. Various aspects of validity and reliability (including face, content and structural validity as well as test-retest reliability) were examined. Three subscales "Autonomy/Alertness", "Gnosias" and "Somatokinetic function" were defined, with a Cronbach equal to 0.851, 0.756 and 0.598 respectively. The GCT subscales and total score were statistically significant higher in patients with MMSE score 1 or 2 compared with those with MMSE score 0 (pGATOS" questionnaire is a valid and reliable test for patients with severe dementia, aiming at identification of those patients who could sustain some quality of life. It is a relatively short and easy to administer tool. As dementia prevalence is expected to rise further worldwide we believe that GCT could offer valuable services to health professionals, caregivers and patients.

  1. Shigella subverts the host recycling compartment to rupture its vacuole.

    Science.gov (United States)

    Mellouk, Nora; Weiner, Allon; Aulner, Nathalie; Schmitt, Christine; Elbaum, Michael; Shorte, Spencer L; Danckaert, Anne; Enninga, Jost

    2014-10-08

    Shigella enters epithlial cells via internalization into a vacuole. Subsequent vacuolar membrane rupture allows bacterial escape into the cytosol for replication and cell-to-cell spread. Bacterial effectors such as IpgD, a PI(4,5)P2 phosphatase that generates PI(5)P and alters host actin, facilitate this internalization. Here, we identify host proteins involved in Shigella uptake and vacuolar membrane rupture by high-content siRNA screening and subsequently focus on Rab11, a constituent of the recycling compartment. Rab11-positive vesicles are recruited to the invasion site before vacuolar rupture, and Rab11 knockdown dramatically decreases vacuolar membrane rupture. Additionally, Rab11 recruitment is absent and vacuolar rupture is delayed in the ipgD mutant that does not dephosphorylate PI(4,5)P₂ into PI(5)P. Ultrastructural analyses of Rab11-positive vesicles further reveal that ipgD mutant-containing vacuoles become confined in actin structures that likely contribute to delayed vacular rupture. These findings provide insight into the underlying molecular mechanism of vacuole progression and rupture during Shigella invasion. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. A method for simulating the release of natural gas from the rupture of high-pressure pipelines in any terrain.

    Science.gov (United States)

    Deng, Yajun; Hu, Hongbing; Yu, Bo; Sun, Dongliang; Hou, Lei; Liang, Yongtu

    2018-01-15

    The rupture of a high-pressure natural gas pipeline can pose a serious threat to human life and environment. In this research, a method has been proposed to simulate the release of natural gas from the rupture of high-pressure pipelines in any terrain. The process of gas releases from the rupture of a high-pressure pipeline is divided into three stages, namely the discharge, jet, and dispersion stages. Firstly, a discharge model is established to calculate the release rate of the orifice. Secondly, an improved jet model is proposed to obtain the parameters of the pseudo source. Thirdly, a fast-modeling method applicable to any terrain is introduced. Finally, based upon these three steps, a dispersion model, which can take any terrain into account, is established. Then, the dispersion scenarios of released gas in four different terrains are studied. Moreover, the effects of pipeline pressure, pipeline diameter, wind speed and concentration of hydrogen sulfide on the dispersion scenario in real terrain are systematically analyzed. The results provide significant guidance for risk assessment and contingency planning of a ruptured natural gas pipeline. Copyright © 2017. Published by Elsevier B.V.

  3. The Brief Multidimensional Students' Life Satisfaction Scale (BMSLSS): Reliability, validity, and gender invariance in an Indian adolescent sample.

    Science.gov (United States)

    Hashim, Jayana; Areepattamannil, Shaljan

    2017-06-01

    This study examined the internal consistency reliability, factorial, convergent, discriminant, and predictive validity, as well as gender invariance of the Brief Multidimensional Students' Life Satisfaction Scale (BMSLSS; Seligson, Huebner, & Valois, 2003) in a sample of 445 adolescents (M age  = 16.04 years) hailing from the southernmost state of India, Kerala. The study also examined the test-retest reliability (n = 392) of the BMSLSS. The Cronbach's alpha coefficient suggested that the BMSLSS was reliable. Confirmatory factor analyses demonstrated the factorial validity of the BMSLSS. Bivariate correlational analyses provided support for the convergent, discriminant, and predictive validity of the BMSLSS. The test-retest reliability coefficient indicated the temporal stability of the BMSLSS. Finally, multi-group confirmatory factor analysis provided support for the gender invariance of the BMSLSS. Copyright © 2017 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  4. The diagnosis of breast implant rupture: MRI findings compared with findings at explantation

    International Nuclear Information System (INIS)

    Hoelmich, Lisbet R.; Vejborg, Ilse; Conrad, Carsten; Sletting, Susanne; McLaughlin, Joseph K.

    2005-01-01

    Study objective: The aim of this study was to evaluate the accuracy of Magnetic Resonance Imaging (MRI) as performed according to a strict study protocol in diagnosing rupture of silicone breast implants. Material and methods: The study population consisted of 64 women with 118 implants, who had participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture (intracapsular or extracapsular), possible rupture or intact implant was then obtained. Strict predetermined rupture criteria were applied as described in this report and findings at surgery were abstracted in a standardised manner and results compared. Results: At MRI, 66 implants were diagnosed as ruptured, nine as possibly ruptured and 43 as intact. Among the ruptured implants, 27 were categorized as extracapsular. At surgery, on average 297 days after the MRI, 65 of the 66 rupture diagnoses were confirmed, as were 20 of the cases with extracapsular silicone. Eight of the nine possibly ruptured implants were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89%, and a specificity of 97%. Correspondingly, the predictive value of a positive MRI examination was 99% and the predictive value of a negative MRI examination was 79%. Conclusions: We conclude that MRI is highly accurate for identification of silicone breast implant rupture, with a high sensitivity and specificity when evaluation of images are based on presence of well-defined rupture criteria

  5. Morphological parameters associated with ruptured posterior communicating aneurysms.

    Science.gov (United States)

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  6. Morphology parameters for intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui

    2008-08-01

    The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P 41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.

  7. Reliability Evaluation of a Concrete Crown Wall on a Rubble Mound Breakwater considering Sliding Failure, Overturning and Rupture Failure of the Foundation

    DEFF Research Database (Denmark)

    Christiani, E.; Sørensen, Jørgen S.; Burcharth, Hans F.

    1994-01-01

    and rupture failure in the rubble mound are taken into account. The method of probabilistic foundation stability analysis is presented by the example of a translation slip failure involving kinematically correct slip surfaces and failure zones in friction based soil. A conventional static quasi-static...

  8. Multi-Canister overpack necessity of the rupture disk

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The Multi-Canister Overpack (MCO) rupture disk precludes the MCO from pressurization above the design limit during transport from the K Basins to the Cold Vacuum Drying (CVD) Facility and prior to connection of the CVD process piping. Removal of the rupture disk from the MCO design would: (a) result in unacceptable dose consequences in the event a thermal runaway accident occurred; (b) increase residual risk; and (c) remove a degree of specificity from the dose calculations. The potential cost savings of removing the rupture disk from the MCO design is offset by the cost of design modifications, changes to hazard analyses and safety analyses, and changes to existing documentation. Retaining the rupture disk mitigates the consequences of MCO overpressurization, and considering the overall economic impacts to the SNF Project, is the most cost effective approach

  9. Right ventricular hydatid cyst ruptured to pericardium

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-01-01

    Full Text Available Cardiac hydatidosis is rare presentation of body hydatidosis. Incidence of cardiac involvements range from 5% to 5% of patients with hydatid disease. Most common site of hydatid cyst in heart is interventricular septum and left ventricular free wall. Right ventricular free wall involvement by cyst that ruptured to pericardial cavity is very rare presentation of hydatid cyst. Cardiac involvement may have serious consequences such as rupture to blood steam or pericardial cavity. Both the disease and its surgical treatment carry a high complication rate, including rupture leading to cardiac tamponade, anaphylaxis and also death. In the present report, a 43-year-old man with constrictive pericarditis secondary to a pericardial hydatid cyst is described.

  10. Reliability-based Assessment of Fatigue Life for Bridges

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2012-01-01

    The reliability level for bridges is discussed based on a comparison of the reliability levels proposed and used by e.g. JCSS, ISO, NKB and Eurocodes. The influence of reserve capacity by which failure of a specific detail does not lead to structural collapse is investigated. The results show...

  11. CT diagnosis of traumatic bronchial rupture in children

    International Nuclear Information System (INIS)

    Epelman, Monica; Ofer, Amos; Guralnik, Ludmila; Klein, Yoram; Best, Leal H.; Bentur, Lea; Traubici, Jeffrey

    2002-01-01

    Bronchial rupture is a rare and serious complication of blunt chest trauma in children. The diagnosis of this injury is challenging and requires a high degree of clinical suspicion. It is frequently associated with other severe injuries that may draw the focus of attention away from this potentially catastrophic but treatable injury. The radiographic findings of bronchial rupture have been reported in very few series. We report the findings in two children with bronchial rupture diagnosed by CT, in whom CT resulted in a significant change in patient management. (orig.)

  12. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  13. Rupture luminescence from natural fibers

    Science.gov (United States)

    Li, W.; Haneman, D.

    1999-12-01

    Fibers of cotton and wool, and samples of paper, have been ruptured in tension in vacuum and in air, and give detectable luminescence in the visible range. All have a common emission peak at around 2.0 eV, which is ascribed to the deexcitation of states excited by the rupture of organic chain molecule bonds. Rubber bands give stronger emission in air, but no emission in vacuum, suggesting the material breaks only at weak interchain bonds. Mohair, cat, and horse hair also give emission in air. The phenomena reveal effects that would occur widely in nature.

  14. Delayed rupture of common carotid artery following rugby tackle injury: a case report

    Directory of Open Access Journals (Sweden)

    Abbas Saleh

    2008-03-01

    Full Text Available Abstract Background Common Carotid Artery (CCA is an uncommon site of injury following a blunt trauma, its presentation with spontaneous delayed rupture is even more uncommon and a rugby tackle leading to CCA injury is a rare event. What makes this case unique and very rare is combination of all of the above. Case presentation Mr H. presented to the Emergency Department with an expanding neck haematoma and shortness of breath. He was promptly intubated and had contrast CT angiography of neck vessels which localized the bleeding spot on posteromedial aspect of his Right CCA. He underwent emergency surgery with repair of the defect and made an uneventful recovery post operatively. Conclusion Delayed post traumatic rupture of the CCA is an uncommon yet potentially life threatening condition which can be caused by unusual blunt injury mechanism. A high index of suspicion and low threshold for investigating carotid injuries in the setting of blunt trauma is likely to be beneficial.

  15. Spontaneous splenic rupture in Waldenstrom's macroglobulinemia: a case report

    Directory of Open Access Journals (Sweden)

    Charakidis Michail

    2010-09-01

    Full Text Available Abstract Introduction We report the case of a patient with Waldenstrom's macroglobulinemia complicated by spontaneous splenic rupture. Case presentation A 49-year-old Caucasian woman was referred to our emergency department by her general practitioner following a three-week history of malaise, night sweats, six kilograms of weight loss, intermittent nausea and vomiting, progressive upper abdominal pain and easy bruising. On the fourth day following her admission, she had a rapid clinical deterioration, with subsequent radiological investigations revealing a splenic rupture. Her morphology, biochemistry, flow cytometry and histology were strongly suggestive of Waldenstrom's macroglobulinemia. Conclusions Spontaneous splenic rupture is not an expected complication of low-grade lymphoplasmacytic lymphomas, such as Waldenstrom's macroglobulinemia. To the best of our knowledge, this is the only reported case of early spontaneous splenic rupture due to Waldenstrom's macroglobulinemia. Our case highlights that despite the typical disease course of low-grade hematological malignancies, signs and symptoms of imminent splenic rupture should be considered when formulating a clinical assessment.

  16. Validity and reliability of the patient assessment of constipation quality of life questionnaire for the Turkish population.

    Science.gov (United States)

    Bengi, Göksel; Yalçın, Mustafa; Akpınar, Hale; Keskinoğlu, Pembe; Ellidokuz, Hülya

    2015-07-01

    There are few specific evaluation forms for evaluating the quality of life among patients with chronic constipation. Our study aimed to determine the validity and reliability of the translated Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire for the Turkish population because evidence of its reliability and validity is required to justify its use in other studies and clinical practice. This study included 154 patients with constipation who were treated at the Department of Gastroenterology, Dokuz Eylül University Hospital between January and June 2012. The translated PAC-QOL questionnaire was completed by patients at the clinic and also at a 2-week follow-up to test its reliability. Cronbach's alpha coefficient (internal consistency) was 0.91 (good) for the translated PAC-QOL questionnaire. Time validity was evaluated using the intraclass correlation coefficient (ICC) method, and the ICC value for all questions was confirmed as 0.68 at the 2-week follow-up. The validity of the tool in the study group was evaluated using factor analysis, and the results were highly significant (Kaiser-Meyer-Olkin value: 0.857; Bartlett's test: p=0.001). Questions were categorized according to six factors based on the factor analysis, and these factors explained 65.1% of the total variation. For hypothesis verification of the tool, the correlation coefficient for PAC-QOL and PAC Symptoms (PAC-SYM) was r=0.577 (p<0.001), whereas the correlation coefficient for PAC-QOL and constipation severity score was r=0.457 (p<0.001). The PAC-QOL questionnaire was reliable, although not valid because of the limited sample group.

  17. Rupture of popliteal arterial aneurysm due to salmonella infection

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Oh, Hyung Woo; Kim, Dong Hyun; Byun, Joo Nam

    2006-01-01

    We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of the extremity that was performed before and after aneurysmal rupture showed the aneurysm's rapid evolution to rupture over a short period of time. We also review the pathogenesis, clinical presentation, diagnostic approach and management of salmonella aneurysms

  18. Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial

    Science.gov (United States)

    Braithwaite, Bruce; Cheshire, Nicholas J.; Greenhalgh, Roger M.; Grieve, Richard; Hassan, Tajek B.; Hinchliffe, Robert; Howell, Simon; Moore, Fionna; Nicholson, Anthony A.; Soong, Chee V.; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Heatley, Francine; Anjum, Aisha; Kalinowska, Gosia; Sweeting, Michael J.; Thompson, Simon G.; Gomes, Manuel; Grieve, Richard; Powell, Janet T.; Ashleigh, Ray; Gomes, Manuel; Greenhalgh, Roger M.; Grieve, Richard; Hinchliffe, Robert; Sweeting, Michael; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Roberts, Ian; Bell, Peter R. F.; Cheetham, Anne; Stephany, Jenny; Warlow, Charles; Lamont, Peter; Moss, Jonathan; Tijssen, Jan; Braithwaite, Bruce; Nicholson, Anthony A.; Thompson, Matthew; Ashleigh, Ray; Thompson, Luke; Cheshire, Nicholas J.; Boyle, Jonathan R.; Serracino-Inglott, Ferdinand; Thompson, Matt M.; Hinchliffe, Robert J.; Bell, Rachel; Wilson, Noel; Bown, Matt; Dennis, Martin; Davis, Meryl; Ashleigh, Ray; Howell, Simon; Wyatt, Michael G.; Valenti, Domenico; Bachoo, Paul; Walker, Paul; MacSweeney, Shane; Davies, Jonathan N.; Rittoo, Dynesh; Parvin, Simon D.; Yusuf, Waquar; Nice, Colin; Chetter, Ian; Howard, Adam; Chong, Patrick; Bhat, Raj; McLain, David; Gordon, Andrew; Lane, Ian; Hobbs, Simon; Pillay, Woolagasen; Rowlands, Timothy; El-Tahir, Amin; Asquith, John; Cavanagh, Steve; Dubois, Luc; Forbes, Thomas L.; Ashworth, Emily; Baker, Sara; Barakat, Hashem; Brady, Claire; Brown, Joanne; Bufton, Christine; Chance, Tina; Chrisopoulou, Angela; Cockell, Marie; Croucher, Andrea; Dabee, Leela; Dewhirst, Nikki; Evans, Jo; Gibson, Andy; Gorst, Siobhan; Gough, Moira; Graves, Lynne; Griffin, Michelle; Hatfield, Josie; Hogg, Florence; Howard, Susannah; Hughes, Cían; Metcalfe, David; Lapworth, Michelle; Massey, Ian; Novick, Teresa; Owen, Gareth; Parr, Noala; Pintar, David; Spencer, Sarah; Thomson, Claire; Thunder, Orla; Wallace, Tom; Ward, Sue; Wealleans, Vera; Wilson, Lesley; Woods, Janet; Zheng, Ting

    2015-01-01

    Aims To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. Methods and results This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI −0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). Conclusion An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. Clinical trial registration ISRCTN 48334791. PMID:25855369

  19. Unusual Cause of Acute Abdomen—Ruptured Retroperitoneal Paraganglioma

    OpenAIRE

    Kwok-Kay Yau; Wing-Tai Siu; Michael Ka-Wah Li

    2008-01-01

    Ruptured retroperitoneal paraganglioma is a rare cause of acute abdomen. Its clinical presentation and laparoscopic features have seldom been reported in the literature. Herein, we report a case of ruptured retroperitoneal paraganglioma that presented as acute abdomen, and its subsequent management.

  20. Delivery of placenta before baby in ruptured uterus | Ameh | Annals ...

    African Journals Online (AJOL)

    An unusual case of ruptured uterus characterized by spontaneous delivery of the placenta while the foetus is retained in the abdomen is presented. The management and prevention of ruptured uterus in Sub- Saharan Africa is discussed. Key Words: Delivery of placenta, ruptured uterus. Annals of African Medicine Vol.3(3) ...

  1. Ruptured uterus in Kano, Nigeria - study of risk factors | Omole ...

    African Journals Online (AJOL)

    This is a comparative prospective study of the risk factors for ruptured uterus in Aminu Kano Teaching Hospital, Kano, Nigeria, between 1st January 2000 and 31st December 2005. Forty six women with ruptured uterus (cases) were compared with two hundred and thirty women who delivered without ruptured uterus ...

  2. Rupture-control via T-Branches - now with precise indication of the rupture; Abrissueberwachung ueber T-Weichen mit Lokalisierung des Abrisses

    Energy Technology Data Exchange (ETDEWEB)

    Lentz, S. [Roetter Industrieelektronik GmbH, Kaiserslautern (Germany)

    2000-05-01

    In hierarchical monitoring systems, normally only the main line can be checked automatically for rupture of the sensor wire. During the AGFW lecture conference in 1998 in Essen, a solution was introduced, where through closing the branch lines with endpieces by the Roetter Industrieelektronik GmbH, the branch lines could be also monitored for ruptures automatically. This process has been further developed since then and now offers the possibility to directly indicate the ruptured branch and if there is more than one rupture, this can be indicated separately as well. (orig.) [German] In hierarchischen Ueberwachungssystemen kann ueblicherweise nur die Hauptleitung automatisch auf Abriss des Sensordrahtes geprueft werden. Bereits auf der AGFW Vortragstagung 1998 in Essen wurde eine Loesung vorgestellt, durch Abschluss der Abzweigleitungen mit Endstuecken von Roetter Industrieelektronik GmbH auch die Abzweigleitungen automatisch auf Abriss zu ueberwachen. Dieses Verfahren wurde praxisgerecht weiterentwickelt und bietet nun die Moeglichkeit, den vom Abriss betroffenen Abzweig direkt anzuzeigen, bei mehreren Abrissen ist jeder einzelne zuzuordnen. (orig.)

  3. The List of Threatening Experiences: the reliability and validity of a brief life events questionnaire.

    Science.gov (United States)

    Brugha, T S; Cragg, D

    1990-07-01

    During the 23 years since the original work of Holmes & Rahe, research into stressful life events on human subjects has tended towards the development of longer and more complex inventories. The List of Threatening Experiences (LTE) of Brugha et al., by virtue of its brevity, overcomes difficulties of clinical application. In a study of 50 psychiatric patients and informants, the questionnaire version of the list (LTE-Q) was shown to have high test-retest reliability, and good agreement with informant information. Concurrent validity, based on the criterion of independently rated adversity derived from a semistructured life events interview, making use of the Life Events and Difficulties Scales (LEDS) method developed by Brown & Harris, showed both high specificity and sensitivity. The LTE-Q is particularly recommended for use in psychiatric, psychological and social studies in which other intervening variables such as social support, coping, and cognitive variables are of interest, and resources do not allow for the use of extensive interview measures of stress.

  4. Splenic artery aneurysm rupture in pregnancy

    International Nuclear Information System (INIS)

    Khan, H.R.; Low, S.; Selinger, M.; Nelson, N.

    2004-01-01

    Rupture of a splenic artery aneurysm, commonly associated with pregnancy is a rare and catastrophic event. We report here a case of a patient in her second pregnancy who presented with a short history of left hypochondriac and epigastric pain, followed by collapse at 32 weeks gestation. Sudden fetal distress lead to emergency caesarean delivery when splenic artery aneurysm rupture was diagnosed. With timely involvement of multidisciplinary personnel both mother and baby survived and had an uneventful recovery. (author)

  5. Life time forecasting method upon occurrence of stress corrosion cracking of structure and test device therefor

    International Nuclear Information System (INIS)

    Anzai, Hideya; Kida, Toshitaka; Urayama, Yoshinao; Kikuchi, Eiji; Shimanuki, Sei; Kuniya, Jiro; Nakata, Kiyotomo; Izumitani, Masakiyo; Hattori, Shigeo.

    1993-01-01

    A load stress is applied to a metal piece made of a material identical with the constituent material of a structure and having the sensitivity enhanced to a predetermined level, and plurality of such pieces are immersed in a corrosive circumstance in this state. Then, the time from the immersion till the rupture thereof and the number of ruptured pieces of the metal pieces are detected while observing them. The relation with the probability of rupture is plotted on a paper to determine the life time for the occurrence of minimum stress corrosion creacks (SSC) of the metal pieces. Based on the relationship between the previously determined stress and the life time for the occurrence of minimum SSC, the ratio between the life time for the occurrence of minimum SSC relative to estimated stress applied to the structure and the life time for the occurrence of minimum SSC relative to the stress applied to the metal pieces is determined as a first SSC acceleration rate. The ratio between the time of occurrence for minimum SSC and the sensitivity is determined as a second SSC acceleration rate. The first and the second SSC acceleration rates are multiplied to estimate the time for the occurrence of SSC of the structure. Then, the life time for the occurrence of SSC for the equipments and structures can be recognized quantitatively, to prevent ruptures of actual equipments and extend the life time. (N.H.)

  6. Triceps Ruptures After Fluoroquinolone Antibiotics: A Report of 2 Cases.

    Science.gov (United States)

    Shybut, Theodore B; Puckett, Ernest R

    Rupture of the triceps brachii tendon is exceedingly rare, and surgical repair is generally indicated. Fluoroquinolone antibiotics have been implicated in tendon pathology, including tendon ruptures. Triceps rupture has not been previously reported in the setting of fluoroquinolone antibiotic therapy. We present 2 cases of triceps tendon rupture after treatment with fluoroquinolones. In both cases, triceps repair was performed with good outcomes. These cases highlight a risk of fluoroquinolone-induced tendinopathy to athletes. The sports medicine team should be aware of this risk and consider it when choosing antibiotics to treat athletes.

  7. Creep Rupture Properties for Base and Weld Metals of Alloy 617

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Kim, Min-Hwan; Park, Jae-Young; Ekaputra, I. M. W.

    2015-01-01

    The allowable deformation in the welds is also restricted to half the deformation permitted for the base metal, since the ductility of the welds at elevated temperatures is generally low. For a design use, the data of the tensile and creep properties for Alloy 617 WM should be sufficiently provided, and in particular, to develop a design code of Alloy 617 WM. However, the data for the WM are very rare and limited until now, although the data for the BM are available in the ASME draft code case, which was suspended at the end of the 1980s owing to a lack of support and interes. In this report, the creep data for Alloy 617 WM, which was fabricated by a gas tungsten arc welding (GTAW) procedure, were obtained by a series of creep tests at 800 .deg. C, and the creep properties of the WM were compared with those of the BM. The high-temperature creep properties for Alloy 617 WM, fabricated by a gas tungsten arc welding (GTAW) procedure, were investigated by a series of creep tests with different stress levels at 800 .deg. C, and the creep test data for the WM were compared with those of the BM. From the results, it was found that the WM had a slightly longer creep rupture life and lower creep rate than the BM, and a particularly lower rupture elongation. The lower creep rate in the WM was due to the lower rupture elongation than the BM

  8. Long-term functional outcome of bilateral spontaneous and simultaneous Achilles tendon ruptures.

    LENUS (Irish Health Repository)

    Ellanti, Prasad

    2012-10-01

    Bilateral simultaneous ruptures are rare comprising less than 1% of all Achilles tendon ruptures. Risk factors for bilateral ruptures include chronic diseases and medications such as corticosteroids and fluoroquinolones. There is little in the literature on the long-term functional outcome of bilateral Achilles tendon ruptures. This article present a series of 3 cases of simultaneous and spontaneous bilateral Achilles tendon ruptures with a minimum of 5-year follow up suggesting a good functional outcome.

  9. Laparoscopic uterine surgery as a risk factor for uterine rupture during pregnancy.

    Directory of Open Access Journals (Sweden)

    An-Shine Chao

    Full Text Available The incidence of uterine rupture through a previous cesarean scar (CS is declining as a result of a lower parity and fewer options for vaginal birth after cesarean. However, uterine ruptures attributable to other causes that traumatize the myometrium are on the rise. To determine whether changes in the causes of uterine rupture had occurred in recent years, we retrospective retrieved the clinical records of all singletons with uterine rupture observed in the delivery room of a Taiwanese tertiary obstetric center over a 15-year period. The overall uterine rupture rate was 3.8 per 10,000 deliveries. A total of 22 cases in 20 women (with two of them experiencing two episodes. Seven uterine ruptures occurred through a previous cesarean scar (CS ruptures, 32%, 13 through a non-cesarean scar (non-CS ruptures, 59%, whereas the remaining two (9% were in women who did not previously undergo any surgery. All of the 13 non-CS ruptures were identified in women with a history of laparoscopic procedures to the uterus. Specifically, 10 (76% occurred after a previous laparoscopic myomectomy, one (8% following a hysteroscopic myomectomy, and two (16% after a laparoscopic wedge resection of cornual ectopic pregnancy. Severe bleeding (blood loss >1500 mL requiring transfusions was more frequent in women who experienced non-CS compared with CS ruptures (10 versus 1 case, respectively, P = 0.024. Patients with a history of endoscopic uterine surgery should be aware of uterine rupture during pregnancy.

  10. Laparoscopic uterine surgery as a risk factor for uterine rupture during pregnancy.

    Science.gov (United States)

    Chao, An-Shine; Chang, Yao-Lung; Yang, Lan-Yan; Chao, Angel; Chang, Wei-Yang; Su, Sheng-Yuan; Wang, Chin-Jung

    2018-01-01

    The incidence of uterine rupture through a previous cesarean scar (CS) is declining as a result of a lower parity and fewer options for vaginal birth after cesarean. However, uterine ruptures attributable to other causes that traumatize the myometrium are on the rise. To determine whether changes in the causes of uterine rupture had occurred in recent years, we retrospective retrieved the clinical records of all singletons with uterine rupture observed in the delivery room of a Taiwanese tertiary obstetric center over a 15-year period. The overall uterine rupture rate was 3.8 per 10,000 deliveries. A total of 22 cases in 20 women (with two of them experiencing two episodes). Seven uterine ruptures occurred through a previous cesarean scar (CS ruptures, 32%), 13 through a non-cesarean scar (non-CS ruptures, 59%), whereas the remaining two (9%) were in women who did not previously undergo any surgery. All of the 13 non-CS ruptures were identified in women with a history of laparoscopic procedures to the uterus. Specifically, 10 (76%) occurred after a previous laparoscopic myomectomy, one (8%) following a hysteroscopic myomectomy, and two (16%) after a laparoscopic wedge resection of cornual ectopic pregnancy. Severe bleeding (blood loss >1500 mL) requiring transfusions was more frequent in women who experienced non-CS compared with CS ruptures (10 versus 1 case, respectively, P = 0.024). Patients with a history of endoscopic uterine surgery should be aware of uterine rupture during pregnancy.

  11. Laparoscopic uterine surgery as a risk factor for uterine rupture during pregnancy

    Science.gov (United States)

    Chao, An-Shine; Chang, Yao-Lung; Yang, Lan-Yan; Chao, Angel; Chang, Wei-Yang; Su, Sheng-Yuan

    2018-01-01

    The incidence of uterine rupture through a previous cesarean scar (CS) is declining as a result of a lower parity and fewer options for vaginal birth after cesarean. However, uterine ruptures attributable to other causes that traumatize the myometrium are on the rise. To determine whether changes in the causes of uterine rupture had occurred in recent years, we retrospective retrieved the clinical records of all singletons with uterine rupture observed in the delivery room of a Taiwanese tertiary obstetric center over a 15-year period. The overall uterine rupture rate was 3.8 per 10,000 deliveries. A total of 22 cases in 20 women (with two of them experiencing two episodes). Seven uterine ruptures occurred through a previous cesarean scar (CS ruptures, 32%), 13 through a non-cesarean scar (non-CS ruptures, 59%), whereas the remaining two (9%) were in women who did not previously undergo any surgery. All of the 13 non-CS ruptures were identified in women with a history of laparoscopic procedures to the uterus. Specifically, 10 (76%) occurred after a previous laparoscopic myomectomy, one (8%) following a hysteroscopic myomectomy, and two (16%) after a laparoscopic wedge resection of cornual ectopic pregnancy. Severe bleeding (blood loss >1500 mL) requiring transfusions was more frequent in women who experienced non-CS compared with CS ruptures (10 versus 1 case, respectively, P = 0.024). Patients with a history of endoscopic uterine surgery should be aware of uterine rupture during pregnancy. PMID:29787604

  12. Validity and reliability of a Nigerian-Yoruba version of the stroke-specific quality of life scale 2.0.

    Science.gov (United States)

    Odetunde, Marufat Oluyemisi; Akinpelu, Aderonke Omobonike; Odole, Adesola Christiana

    2017-10-19

    Psychometric evidence is necessary to establish scientific integrity and clinical usefulness of translations and cultural adaptations of the Stroke-Specific Quality of Life (SS-QoL) scale. However, the limited evidence on psychometrics of Yoruba version of SS-QoL 2.0 (SS-QoL(Y)) is a significant shortcoming. This study assessed the test-retest reliability, internal consistency, convergent, divergent, discriminant and known-group validity of the SS-QoL(Y). Yoruba version of the WHOQoL-BREF was used to test the convergent and divergent validity of the SS-QoL(Y) among 100 consenting stroke survivors. The WHOQoL-BREF and SS-QoL(Y) was administered randomly in order to eliminate bias. The test-retest reliability of the SS-QoL(Y) was carried out among 68 of the respondents within an interval of 7 days. All respondents were purposively recruited from selected secondary and tertiary health facilities in South-west Nigeria. Data were analysed using descriptive statistics of mean and standard deviation, and inferential statistics of Spearman correlation, Cronbach's alpha, Intra-class Correlation Coefficient (ICC), Independent t-test and One-way ANOVA. Alpha level was set at p validity of SS-QoL(Y) showed that items' r value ranged from 0.711 to 0.920 with their hypothesized domains. The scale demonstrated moderate to strong test-retest reliability with Intra-class correlation coefficient (ICC) for the domains and overall scores (r = 0.47 to 0.81) and moderate to high internal consistency (Cronbach's alpha =0.61 to 0.82) for domains scores. These correlations were also significant for the domains and overall scores (p validity, test-retest reliability and internal consistency of the Yoruba version of the Stroke Specific Quality of Life 2.0 are adequate while the convergent and divergent validity are low but acceptable. The SS-QoL(Y) is recommended for assessing health-related quality of life among Yoruba stroke survivors.

  13. Spontaneous Tricuspid Valve Chordal Rupture in Idiopathic Pulmonary Hypertension.

    Science.gov (United States)

    Rodrigues, Ana Clara Tude; Afonso, José E; Cordovil, Adriana; Monaco, Claudia; Piveta, Rafael; Cordovil, Rodrigo; Fischer, Claudio H; Vieira, Marcelo; Lira-Filho, Edgar; Morhy, Samira S

    2016-03-01

    Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed. © 2015, Wiley Periodicals, Inc.

  14. Amnioinfusion for preterm rupture of membranes.

    Science.gov (United States)

    Hofmeyr, G J

    2000-01-01

    Preterm rupture of membranes places a fetus at risk of cord compression and amnionitis. Amnioinfusion aims to prevent or relieve umbilical cord compression by infusing a solution into the uterine cavity. The objective of this review was to assess the effects of amnioinfusion for preterm rupture of membranes on maternal and perinatal outcomes. The Cochrane Pregnancy and Childbirth Group trials register and the Cochrane Controlled Trials Register were searched. Randomised trials of amnioinfusion compared to no amnioinfusion in women with preterm rupture of membranes. Eligibility and trial quality were assessed by the reviewer. One trial of 66 women was included. It had some methodological flaws. No significant differences between amnioinfusion and no amnioinfusion were detected for caesarean section (relative risk 0.32, 95% confidence interval 0.07 to 1.40); low Apgar scores (relative risk 0.28, 95% confidence interval 0.03 to 2.33) or neonatal death (relative risk 0.55, 95% confidence interval 0.05 to 5.77). In the amnioinfusion group, the number of severe fetal heart rate decelerations per hour during the first stage of labour were reduced (weighted mean difference -1.20, 95% confidence interval -1.83 to -0.57). These outcomes are consistent with those found in the Cochrane review on amnioinfusion for cord compression. There is not enough evidence concerning the use of amnioinfusion for preterm rupture of membranes.

  15. Premature rupture of membranes

    Science.gov (United States)

    ... gov/ency/patientinstructions/000512.htm Premature rupture of membranes To use the sharing features on this page, ... water that surrounds your baby in the womb. Membranes or layers of tissue hold in this fluid. ...

  16. Life prediction and mechanical reliability of NT551 silicon nitride

    Science.gov (United States)

    Andrews, Mark Jay

    551. For the same reasons, the predicted and actual fatigue performance did not correlate well. The results of this study should not be considered a limitation of the life prediction algorithm but emphasize the requirement that ceramics be homogeneous and strength-limiting flaws uniformly distributed as a perquisite for accurate life prediction and reliability analyses.

  17. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  18. Unusual Cause of Acute Abdomen—Ruptured Retroperitoneal Paraganglioma

    Directory of Open Access Journals (Sweden)

    Kwok-Kay Yau

    2008-01-01

    Full Text Available Ruptured retroperitoneal paraganglioma is a rare cause of acute abdomen. Its clinical presentation and laparoscopic features have seldom been reported in the literature. Herein, we report a case of ruptured retroperitoneal paraganglioma that presented as acute abdomen, and its subsequent management.

  19. Creep rupture behavior of welded Grade 91 steel

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Triratna [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Basirat, Mehdi [Department of Mechanical Engineering, University of Idaho, Moscow, ID 83844 (United States); Alsagabi, Sultan; Sittiho, Anumat [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Charit, Indrajit, E-mail: icharit@uidaho.edu [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Potirniche, Gabriel P. [Department of Mechanical Engineering, University of Idaho, Moscow, ID 83844 (United States)

    2016-07-04

    Creep rupture behavior of fusion welded Grade 91 steel was studied in the temperature range of 600 – 700 °C and at stresses of 50–200 MPa. The creep data were analyzed in terms of the Monkman-Grant relation and Larson-Miller parameter. The creep damage tolerance factor was used to identify the origin of creep damage. The creep damage was identified as the void growth in combination with microstructural degradation. The fracture surface morphology of the ruptured specimens was studied by scanning electron microscopy and deformed microstructure examined by transmission electron microscopy, to further elucidate the rupture mechanisms.

  20. Blunt cardiac rupture in a toddler

    Directory of Open Access Journals (Sweden)

    Peep Talving

    2016-08-01

    Full Text Available Blunt cardiac rupture is typically a fatal injury with overall mortality exceeding 90%. Most of the patients never reach the hospital alive. In pediatric patients, only 0.03% of cases following blunt trauma admissions have a cardiac injury. This report presents a rare survivor of 16-months old toddler injured in a domestic accident suffering a right atrial rupture repaired through a median sternotomy. To the best of our knowledge this is the youngest case reported in the literature.

  1. Creep strength and rupture ductility of creep strength enhanced ferritic steels

    Energy Technology Data Exchange (ETDEWEB)

    Kushima, Hideaki; Sawada, Kota; Kimura, Kazuhiro [National Inst. for Materials Science, Tsukuba, Ibaraki (Japan)

    2010-07-01

    Creep strength and rupture ductility of Creep Strength Enhanced Ferritic (CSEF) steels were investigated from a viewpoint of stress dependence in comparison with conventional low alloy ferritic creep resistant steels. Inflection of stress vs. time to rupture curve was observed at 50% of 0.2% offset yield stress for both CSEF and conventional ferritic steels. Creep rupture ductility tends to decrease with increase in creep exposure time, however, those of conventional low alloy steels indicate increase in the long-term. Creep rupture ductility of the ASME Grades 92 and 122 steels indicates drastic decrease with decrease in stress at 50% of 0.2% offset yield stress. Stress dependence of creep rupture ductility of the ASME Grades 92 and 122 steels is well described by stress ratio to 0.2% offset yield stress, regardless of temperature. Drop of creep rupture ductility is caused by inhomogeneous recovery at the vicinity of prior austenite grain boundary, and remarkable drop of creep rupture ductility of CSEF steels should be derived from those stabilized microstructure. (orig.)

  2. [Achilles tendon ruptures: 25 year's experience in sport-orthopedic treatment].

    Science.gov (United States)

    Majewski, M; Widmer, K H; Steinbrück, K

    2002-12-01

    From 1972 - 1996 570 Achilles tendon ruptures in 565 patients were treated in the Sportklinik Stuttgart. The 499 men and 66 women had an average age of 38 years. For the diagnosis of a Achilles tendon rupture Ultrasound and MRI are important procedures, but clinical history and examination are still the best methods to find an Achilles tendon rupture (100%). However,the Actiology of the Achilles tendon rupture is still controversial and cannot be answered by these methods. Opposed to the degenerative theory, biomechanical experiments show that any Achilles tendon can tear when the calf muscle is tensed before the tendon is quickly stretched. We found that 69.8% of the patients with Achilles tendon rupture had a real trauma. Regardless of that, the treatment of the ruptured Achilles tendon has considerably changed over the last ten years. Responsible for this development are the positive experiences at the field of sports medicine with minimally invasive methods and the early functional treatment after knee surgery. Since we use an early functional rehabilitation concept instead of plaster immobilisation, all methods to treat a ruptured Achilles tendon have been improved. 43.5% of the patients after plaster immobilisation and 28.8% of the patients after early functional rehabilitation had a subjectively felt force reduction. Other important selecting criteria are the risk factors related to treatment method. Minimal invasive percutaneous Achilles tendon repair is considerably better than conservative therapy with a high rate of re-rupture (9.8%) and better than the open surgical repair, which carries a higher risk of infection (2.2%)

  3. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  4. Rupture of the neck in nuclear fission

    International Nuclear Information System (INIS)

    Davies, K.T.R.; Managan, R.A.; Nix, J.R.; Sierk, A.J.

    1977-01-01

    We introduce a degree of freedom to describe the rupture of the neck in nuclear fission and calculate the point at which the neck ruptures as the nucleus descends dynamically from its fission saddle point. This is done by mentally slicing the system into two portions at its minimum neck radius and calculating the force required to separate the two portions while keeping their shapes fixed. This force is obtained by differentiating with respect to separation the sum of the Coulomb and nuclear interaction energies between the two portions. For nuclei throughout the Periodic Table we calculate this force along dynamical paths leading from the fission saddle point. The force is initially attractive but becomes repulsive when the neck reaches a critical size. For actinide nuclei the neck radius at which rupture occurs is about 2 fm. This increases the calculated translational kinetic energy of the fission fragments at infinity relative to that calculated for scission occurring at zero neck radius. With the effect of neck rupture taken into account, we calculate and compare with experimental results fission-fragment kinetic energies for two types of nuclear dissipation: ordinary two-body viscosity and one-body dissipation

  5. Influences of cyclic deformation on creep property and creep-fatigue life prediction considering them

    International Nuclear Information System (INIS)

    Takahashi, Yukio

    2009-01-01

    Evaluation of creep-fatigue is essential in design and life management of high-temperature components in power generation plants. Cyclic deformation may alter creep property of the materials and its consideration may improve predictability of creep-fatigue failure life. To understand them, creep tests were conducted for the materials subjected to cyclic loading and their creep rupture and deformation behaviors were compared with those of as-received materials. Both 316FR and modified 9Cr-1Mo steel were tested. (1) Creep rupture time and elongation generally tend to decrease with cyclic loading in both materials, and especially elongation of 316FR drastically decreases by being cyclically deformed. (2) Amount of primary creep deformation decreases by cyclic loading and the ways to improve its predictability were developed. (3) Use of creep rupture ductility after cyclic deformation, instead of that of as-received material, brought about clear improvement of life prediction in a modified ductility exhaustion approach. (author)

  6. Validity, reliability and understanding of the EORTC-C30 and EORTC-BR23, quality of life questionnaires specific for breast cancer

    Directory of Open Access Journals (Sweden)

    Fernanda Alessandra Silva Michels

    2013-06-01

    Full Text Available Objective: To validate and assess reliability and understanding of the EORTC–C30 quality of life questionnaire and its breast cancer specific module, the EORTC-BR23. Methods: This study was conducted at the AC Camargo Cancer Hospital, São Paulo, Brazil. A total of 100 women diagnosed with breast cancer were interviewed. Internal consistency, confirmatory factorial analysis, convergent validity, construct validity and degree of understanding were examined. Reliability was assessed by comparison of means at times 1 and 2, inter-class coefficient and Bland-Altman graphics. Results: Cronbach’s alpha ranged from 0.72 to 0.86 for the EORTC-C30 and from 0.78 to 0.83 for the EORTC-BR23 questionnaire. Most questions were confirmed in the confirmatory factorial analysis. In the construct validity analysis, the questionnaires were capable of differentiating patients with or without lymphedema, apart from the symptom scales of both questionnaires. Both questionnaires presented a significant correlation in most domains of the SF-36, in the convergent validity analysis. Only a few criticisms were reported concerning questions, and the mean grade of understanding was high (C30 = 4.91 and BR23 = 4.89. The questionnaires presented good rates of reliability, with the exception of the functional scale of the C30 and the symptom scale of the BR23. Conclusions: The EORTC-C30 and EORTC-BR23 quality of life questionnaires were validated, presented good rates of reliability and are easily understood, allowing them to be used in Brazil to assess quality of life among women with breast cancer.

  7. Four cases of spontaneous rupture of the urinary bladder

    International Nuclear Information System (INIS)

    Amano, Toshiyasu; Miwa, Sotaro; Takashima, Hiroshi; Takemae, Katsuro

    2002-01-01

    Between November 1997 and March 2001, 4 female patients from 44 to 65 years of age with a spontaneous rupture of the urinary bladder were analyzed. They complained of abdominal pain and had undergone an intra-pelvic gynecological operation (3 for uterine cancer, 1 for an ovarian cyst) several years before. The three with uterine cancer had also received radiation therapy. For their present condition, spontaneous urinary bladder rupture, their treatment was indwelling a urethral catheter. Two of them have had no recurrence of urinary bladder rupture after one month since having the urethral catheter indwelt. One, however, had to have the catheter re-indwelt due to unsuccessful suturing of the urinary bladder wall. The fourth patient had bilateral nephrostomy tubes due to severe radiation cystitis. Thus, one can infer that intra-pelvic gynecological operations and radiation therapy are major factors causing spontaneous urinary bladder rupture. While indwelling a urethral catheter may be effective for some patients with a spontaneous rupture of the urinary bladder, it may be very difficult to treat more complicated cases. (author)

  8. Radiologic analysis of the medical collateral ligament rupture

    International Nuclear Information System (INIS)

    Cho, Chung Che; Lee, Chang Jun; Kim, Kun Sang; Park, Soo Soung

    1979-01-01

    The medical collateral ligament rupture is the most common injury involving the knee joint ligaments. The ruptured medical collateral ligaments of 73 cases with clinical and surgical confirmations were radiologically analyzed. The results were obtained as follows: 1. The most risky age for tearing of the medical collateral ligament was third to fifth decades (50 cases of male and 23 of females). 2. The most common cause of the medical collateral ligament rupture was traffic accident (82.2%). 3. The mean distance of medial knee joint space was 7.9 ± 2.0 mm on the normal side and 13.7 ± 4.2 mm on the affected side. 4. The mean degree of knee joint space was 10.1 ± 2.5 on the normal side and 14.7 ± 3.8 on the affected side. 5. The fibula was the bone fractured most frequently in association with the medial collateral ligament rupture (30.6%).

  9. The transition of dynamic rupture styles in elastic media under velocity-weakening friction

    KAUST Repository

    Gabriel, A.-A.

    2012-09-01

    Although kinematic earthquake source inversions show dominantly pulse-like subshear rupture behavior, seismological observations, laboratory experiments and theoretical models indicate that earthquakes can operate with different rupture styles: either as pulses or cracks, that propagate at subshear or supershear speeds. The determination of rupture style and speed has important implications for ground motions and may inform about the state of stress and strength of active fault zones. We conduct 2D in-plane dynamic rupture simulations with a spectral element method to investigate the diversity of rupture styles on faults governed by velocity-and-state-dependent friction with dramatic velocity-weakening at high slip rate. Our rupture models are governed by uniform initial stresses, and are artificially initiated. We identify the conditions that lead to different rupture styles by investigating the transitions between decaying, steady state and growing pulses, cracks, sub-shear and super-shear ruptures as a function of background stress, nucleation size and characteristic velocity at the onset of severe weakening. Our models show that small changes of background stress or nucleation size may lead to dramatic changes of rupture style. We characterize the asymptotic properties of steady state and self-similar pulses as a function of background stress. We show that an earthquake may not be restricted to a single rupture style, but that complex rupture patterns may emerge that consist of multiple rupture fronts, possibly involving different styles and back-propagating fronts. We also demonstrate the possibility of a super-shear transition for pulse-like ruptures. Finally, we draw connections between our findings and recent seismological observations.

  10. The transition of dynamic rupture styles in elastic media under velocity-weakening friction

    KAUST Repository

    Gabriel, A.-A.; Ampuero, J.-P.; Dalguer, L. A.; Mai, Paul Martin

    2012-01-01

    Although kinematic earthquake source inversions show dominantly pulse-like subshear rupture behavior, seismological observations, laboratory experiments and theoretical models indicate that earthquakes can operate with different rupture styles: either as pulses or cracks, that propagate at subshear or supershear speeds. The determination of rupture style and speed has important implications for ground motions and may inform about the state of stress and strength of active fault zones. We conduct 2D in-plane dynamic rupture simulations with a spectral element method to investigate the diversity of rupture styles on faults governed by velocity-and-state-dependent friction with dramatic velocity-weakening at high slip rate. Our rupture models are governed by uniform initial stresses, and are artificially initiated. We identify the conditions that lead to different rupture styles by investigating the transitions between decaying, steady state and growing pulses, cracks, sub-shear and super-shear ruptures as a function of background stress, nucleation size and characteristic velocity at the onset of severe weakening. Our models show that small changes of background stress or nucleation size may lead to dramatic changes of rupture style. We characterize the asymptotic properties of steady state and self-similar pulses as a function of background stress. We show that an earthquake may not be restricted to a single rupture style, but that complex rupture patterns may emerge that consist of multiple rupture fronts, possibly involving different styles and back-propagating fronts. We also demonstrate the possibility of a super-shear transition for pulse-like ruptures. Finally, we draw connections between our findings and recent seismological observations.

  11. Experience and modeling of radioactivity transport following steam generator tube rupture

    International Nuclear Information System (INIS)

    Hopenfeld, J.

    1985-01-01

    A review of the capabilities of the CITADEL computer code as well as plant experience to project radioactivity releases following a steam generator tube rupture in pressurized-water reactors shows that certain experimental data are needed for reliable offsite dose predictions. This article defines five parameters that are the key for such predictions and discusses the functional dependence of these parameters on various operational variables. The above parameters can be used in conjuction with CITADEL or they can be inserted in the appropriate equations, which then can be programmed conveniently as a subroutine in thermal-hydraulic system codes. A joint Westinghouse Electric Corporation, Electric Power Research Institute, and Nuclear Regulatory Commission program aimed at obtaining the five parameters empirically is described

  12. Creep and rupture of an ODS alloy with high stress rupture ductility. [Oxide Dispersion Strengthened

    Science.gov (United States)

    Mcalarney, M. E.; Arsons, R. M.; Howson, T. E.; Tien, J. K.; Baranow, S.

    1982-01-01

    The creep and stress rupture properties of an oxide (Y2O3) dispersion strengthened nickel-base alloy, which also is strengthened by gamma-prime precipitates, was studied at 760 and 1093 C. At both temperatures, the alloy YDNiCrAl exhibits unusually high stress rupture ductility as measured by both elongation and reduction in area. Failure was transgranular, and different modes of failure were observed including crystallographic fracture at intermediate temperatures and tearing or necking almost to a chisel point at higher temperatures. While the rupture ductility was high, the creep strength of the alloy was low relative to conventional gamma prime strengthened superalloys in the intermediate temperature range and to ODS alloys in the higher temperature range. These findings are discussed with respect to the alloy composition; the strengthening oxide phases, which are inhomogeneously dispersed; the grain morphology, which is coarse and elongated and exhibits many included grains; and the second phase inclusion particles occurring at grain boundaries and in the matrix. The creep properties, in particular the high stress dependencies and high creep activation energies measured, are discussed with respect to the resisting stress model of creep in particle strengthened alloys.

  13. Reliability data collection on IC and VLSI devices tested under accelerated life conditions

    International Nuclear Information System (INIS)

    Barry, D.M.; Meniconi, M.

    1986-01-01

    As part of a more general investigation into the reliability and failure causes of semiconductor devices, statistical samples of integrated circuit devices (LM741C) and dynamic random access memory devices (TMS4116) were tested destructively to failure using elevated temperature as the accelerating stress. The devices were operated during the life test and the failure data generated were collected automatically using a multiple question-and-answer program and a process control computer. The failure data were modelled from the lognormal, inverse Gaussian and Weibull distribution using an Arrhenius reaction rate model. The failed devices were later decapsulated for failure cause determination. (orig./DG)

  14. Physiotherapy in patients with rupture LCA

    OpenAIRE

    Čížková, Karolína

    2012-01-01

    Author: Karolína Čížková Institution: Rehab clinic LF UK in Hradec Králové Topic of bachelor's thesis: Physiotherapy in patiens with rupture of ACL Supervisor: Mgr. Zuzana Hamarová Number of pages: 108 Number of annex: 11 Year of vindication 2012 Key words: ACL, knee, rupture of ACL, rehabilitation In general part of this bachelor's thesis is described anatomy, kinesiology and biomechanics of the knee joint, mostly anterior cruciate ligament. It contents causes of injury of anterior cruciate ...

  15. Spontaneous Pre-Labour Rupture of Membranes at Term ...

    African Journals Online (AJOL)

    BACKGROUND: Spontaneous pre-labour rupture of membranes (SPROM) at term is one of the most common complications of pregnancy. It is an important cause of perinatal morbidity and mortality, particularly because it is associated with a latency period from membrane rupture to delivery. OBJECTIVE: To compare the ...

  16. An Analysis of Surgical Treatment for the Spontaneous Rupture of Hepatocellular Carcinoma.

    Science.gov (United States)

    Sada, Haruki; Ohira, Masahiro; Kobayashi, Tsuyoshi; Tashiro, Hirotaka; Chayama, Kazuaki; Ohdan, Hideki

    2016-01-01

    The prognosis of spontaneous rupture of hepatocellular carcinoma (HCC) remains unclear. We investigated the prognosis of patients with ruptured HCC based on the treatments and prognostic factors associated with long-term survival. The prognoses of 64 consecutive patients treated for ruptured HCC from 1986 to 2013 were analyzed according to their methods of treatment. The prognostic factors of 16 surgical patients were identified, and their overall survival (OS) and recurrence rates were compared to 1,157 surgical patients who underwent surgery for non-ruptured HCC. The surgical outcomes were also compared using a propensity score matching method. Surgery was associated with a better OS. Curative resection was the only independent prognostic factor in surgical patients with ruptured HCC (p = 0.040). Although the OS of surgical patients with non-ruptured HCC was found to be significantly better than that of the patients with ruptured HCC, no significant difference in OS was observed after propensity score matching. A curative resection should be the objective of treatment, assuming the suitability of the patient's clinical condition. When the liver function reserve and tumor extension of patients with ruptured and non-ruptured HCC are similar, then their surgical outcomes may not be significantly different. © 2015 S. Karger AG, Basel.

  17. Multiple Tophaceous Gout of Hand with Extensor Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Haruki Tobimatsu

    2017-01-01

    Full Text Available A 45-year-old man presented with painless subcutaneous masses bilaterally on his hands and loss of motion or contracture of the fingers. Initially, drug therapy to reduce the serum uric acid was administered and was expected to reduce the tophi. However, during observation at the clinic, spontaneous rupture of an extensor tendon occurred, and surgical repair of the tendon and resection of the masses were performed. Surgical exploration of the right hand showed hypertrophic white-colored crystal deposits that both surrounded and invaded the extensor digitorum communis of the index finger, which was ruptured. Histopathologic examination of the specimen demonstrated findings consistent with gouty tophi. Tophaceous gout can induce a rupture of tendons during clinical observation, and surgical resection of the tophi might be needed to prevent ruptures.

  18. Rupture Dynamics and Ground Motion from Earthquakes in Heterogeneous Media

    Science.gov (United States)

    Bydlon, S.; Dunham, E. M.; Kozdon, J. E.

    2012-12-01

    Heterogeneities in the material properties of Earth's crust scatter propagating seismic waves. The effects of scattered waves are reflected in the seismic coda and depend on the relative strength of the heterogeneities, spatial arrangement, and distance from source to receiver. In the vicinity of the fault, scattered waves influence the rupture process by introducing fluctuations in the stresses driving propagating ruptures. Further variability in the rupture process is introduced by naturally occurring geometric complexity of fault surfaces, and the stress changes that accompany slip on rough surfaces. We have begun a modeling effort to better understand the origin of complexity in the earthquake source process, and to quantify the relative importance of source complexity and scattering along the propagation path in causing incoherence of high frequency ground motion. To do this we extended our two-dimensional high order finite difference rupture dynamics code to accommodate material heterogeneities. We generate synthetic heterogeneous media using Von Karman correlation functions and their associated power spectral density functions. We then nucleate ruptures on either flat or rough faults, which obey strongly rate-weakening friction laws. Preliminary results for flat faults with uniform frictional properties and initial stresses indicate that off-fault material heterogeneity alone can lead to a complex rupture process. Our simulations reveal the excitation of high frequency bursts of waves, which radiate energy away from the propagating rupture. The average rupture velocity is thus reduced relative to its value in simulations employing homogeneous material properties. In the coming months, we aim to more fully explore parameter space by varying the correlation length, Hurst exponent, and amplitude of medium heterogeneities, as well as the statistical properties characterizing fault roughness.

  19. Radiological features of 80 cases of diaphragmatic rupture

    International Nuclear Information System (INIS)

    Sullivan, M.; Lee, R.

    1989-01-01

    The films from 80 cases of diaphragmatic rupture in the dog and cat over a 10 year period were examined. The most common findings were loss of the cupola and masking of the cardiac shadow. Identification of the stomach or intestine in the thorax made the diagnosis straightforward. However, in some animals these organs were not visible and there was considerable accumulation of free pleural fluid. The use of barium contrast studies and post drainage films were unable to confirm the presence of a rupture in all cases with inconclusive plain film findings. The identification of a rupture was only made by exploratory surgery in these animals

  20. Recent advances in computational structural reliability analysis methods

    Science.gov (United States)

    Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.

    1993-10-01

    The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.

  1. Retrospective Review of Pectoralis Major Ruptures in Rodeo Steer Wrestlers

    Directory of Open Access Journals (Sweden)

    Breda H. F. Lau

    2013-01-01

    Full Text Available Background. Pectoralis major tendon ruptures have been reported in the literature as occupational injuries, accidental injuries, and sporting activities. Few cases have been reported with respect to rodeo activities. Purpose. To describe a series of PM tendon ruptures in professional steer wrestlers. Study Design. Case series, level of evidence, 4. Methods. A retrospective analysis of PM ruptures in a steer wrestling cohort was performed. Injury data between 1992 and 2008 were reviewed using medical records from the University of Calgary Sport Medicine Center. Results. Nine cases of pectoralis major ruptures in professional steer wrestlers were identified. Injuries occurred during the throwing phase of the steer or while breaking a fall. All athletes reported unexpected or abnormal behavior of the steer that contributed to the mechanism of injury. Seven cases were surgically repaired, while two cases opted for nonsurgical intervention. Eight cases reported successful return to competition following the injury. Conclusion. Steer wrestlers represent a unique cohort of PM rupture case studies. Steer wrestling is a demanding sport that involves throwing maneuvers that may predispose the muscle to rupture. All cases demonstrated good functional outcomes regardless of surgical or non-surgical treatment.

  2. Effects of botulinum toxin A injection on healing and tensile strength of ruptured rabbit Achilles tendons.

    Science.gov (United States)

    Tuzuner, Serdar; Özkan, Özlenen; Erin, Nuray; Özkaynak, Sibel; Cinpolat, An; Özkan, Ömer

    2015-04-01

    Tendon lacerations are most commonly managed with surgical repair. Postoperative complications such as adhesions and ruptures often occur with immobilization. Early postoperative mobilization is therefore advised to minimize complications and time required to return to daily life. The aim of this study was to evaluate whether botulinum neurotoxin type-A (BoNT-A) can be used to enhance healing and prevent rupture in mobilized animals with Achilles tenotomy. Twenty-seven rabbits were divided into 3 groups, namely, I, II, and III, after surgical 1-sided Achilles tenotomy and end-to-end repair. The control group for biomechanical comparisons consisted of randomly selected contralateral (unoperated) healthy Achilles tendons. Group I received BoNT-A (4 U/kg) injection into the calf muscles. One week later, electromyographical confirmation was performed to establish the effects of injection. Surgery was then performed. Animals in the second group (n = 9, group II) were immobilized with a cast postoperatively. The third group (n = 9, group III) was mobilized immediately with no cast or BoNT-A. Tendons were harvested and gap formation or ruptures as well as strength of the repaired tendon were assessed 6 weeks after surgery. Achilles tendons healed in all animals injected with BoNT-A, whereas all were ruptured in group III. All Achilles tendons of animals in groups I and II healed. However, group I repaired tendons were biomechanically equivalent to healthy tendons, whereas group II repaired tendons demonstrated significantly decreased tensile strength (P = 0.009). The present study suggests that local injection of BoNT-A can be used for treatment of tendon rupture and may replace the use of cast for immobilization. However, further studies are needed to determine whether BoNT-A injection can have a beneficial effect on the healing of tendon repairs in humans.

  3. Delayed primary realignment of posterior urethral rupture | Shittu ...

    African Journals Online (AJOL)

    The treatment of acute posterior urethral rupture is controversial. Twelve patients who presented with acute posterior urethral rupture over a five--year period were treated by delayed primary realignment of the injury. The technique of this procedure and the outcome are the subject of this presentation. Eight patients had ...

  4. Spontaneous calyceal rupture caused by a ureteral calculus ...

    African Journals Online (AJOL)

    Rupture of the urinary collecting system with perirenal and retroperitoneal extravasation of the urine is an unusual condition that is typically caused by ureteral-obstructing calculi. We report a case of calyceal rupture with urinoma formation, due to a stone in the distal ureter. The diagnosis was confirmed by computed ...

  5. Spontaneous calyceal rupture caused by a ureteral calculus

    African Journals Online (AJOL)

    A. Chaabouni

    Ureteral calculus;. CT;. Ureterel stent. Abstract. Rupture of the urinary collecting system with perirenal and retroperitoneal extravasation of the urine is an unusual condition that is typically caused by ureteral-obstructing calculi. We report a case of calyceal rupture with urinoma formation, due to a stone in the distal ureter.

  6. Recurrent spontaneous bladder rupture cured by conservative therapy. A case report

    International Nuclear Information System (INIS)

    Hagiwara, Noriyasu; Nishida, Yasuyuki; Fujimoto, Yoshinori; Isogai, Kazutoshi; Fujihiro, Shigeru; Deguchi, Takashi

    2002-01-01

    The patient was a 44-year-old woman, who had undergone radical hysterectomy and postoperative radiation therapy for cervical cancer at the age of 34 years old. In 1998, she was admitted to our hospital with chief complaints of acute abdominal pain and high fever. We made a diagnosis of spontaneous bladder rupture associated with neurogenic bladder dysfunction and radiation cystitis, based on findings of cystoscopy and cystography. She was cured by conservative therapy, including catheter drainage and antibacterial chemotherapy. Thereafter, she was managed with intermittent self-catheterization. In 2000, spontaneous bladder rupture recurred, but conservative therapy was effective again. A review of 12 cases of recurrent spontaneous bladder rupture in Japan, including the present case, suggests that proper management of urination for neurogenic bladder dysfunction may be necessary for prevention of recurrent rupture, when the impaired bladder is left after either successful conservative or surgical treatment of bladder rupture. Urinary diversion and augmentation cystoplasty should be considered for repeated rupture of the bladder. (author)

  7. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  8. Alliance Rupture and Resolution in Dialectical Behavior Therapy for Borderline Personality Disorder.

    Science.gov (United States)

    Boritz, Tali; Barnhart, Ryan; Eubanks, Catherine F; McMain, Shelley

    2018-01-01

    The aim of this exploratory study was to investigate alliance rupture and resolution processes in the early sessions of a sample of clients who underwent 1 year of standard dialectical behavior therapy (DBT) for borderline personality disorder (BPD). Participants were three recovered and three unrecovered clients drawn from the DBT arm of a randomized controlled trial that compared the clinical and cost-effectiveness of DBT and general psychiatric management. Alliance rupture and resolution processes were coded using the observer-based Rupture Resolution Rating Scale. Unrecovered clients evidenced a higher frequency of withdrawal ruptures than recovered clients. Withdrawal ruptures tended to persist for unrecovered clients despite the degree of resolution in the prior session, unlike for recovered clients, for whom the probability of withdrawal ruptures decreased as the degree of resolution increased. This study suggests that alliance rupture and resolution processes in early treatment differ between recovered and unrecovered clients in DBT for BPD.

  9. Application of probabilistic fracture mechanics to estimate the risk of rupture of PWR steam generator tubes

    International Nuclear Information System (INIS)

    Pitner, P.; Riffard, T.; Granger, B.

    1992-01-01

    This paper describes the COMPROMIS code developed by Electricite de France (EDF) to optimize the tube bundle maintenance of steam generators. The model, based on probabilistic fracture mechanics, makes it possible to quantify the influence of in-service inspections and maintenance work on the risk of an SG tube rupture, taking all significant parameters into account as random variables (initial defect size distribution, reliability of non-destructive detection and sizing, crack initiation and propagation, critical sizes, leak before risk of break, etc.). (authors). 5 refs., 8 figs., 3 tabs

  10. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms.

    Directory of Open Access Journals (Sweden)

    Nan Lv

    Full Text Available The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA aneurysms.In 129 PCoA aneurysms (85 ruptured, 44 unruptured, clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms.While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR, size ratio (SR, dome-to-neck ratio (DN, inflow angle (IA, normalized wall shear stress (NWSS and percentage of low wall shear stress area (LSA were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p < 0.001 and LSA (OR = 1.393, p = 0.041.Hemodynamics and morphology were related to rupture status of intracranial aneurysms. Higher IA and LSA were identified as discriminators for rupture status of PCoA aneurysms.

  11. Influence of fault steps on rupture termination of strike-slip earthquake faults

    Science.gov (United States)

    Li, Zhengfang; Zhou, Bengang

    2018-03-01

    A statistical analysis was completed on the rupture data of 29 historical strike-slip earthquakes across the world. The purpose of this study is to examine the effects of fault steps on the rupture termination of these events. The results show good correlations between the type and length of steps with the seismic rupture and a poor correlation between the step number and seismic rupture. For different magnitude intervals, the smallest widths of the fault steps (Lt) that can terminate the rupture propagation are variable: Lt = 3 km for Ms 6.5 6.9, Lt = 4 km for Ms 7.0 7.5, Lt = 6 km for Ms 7.5 8.0, and Lt = 8 km for Ms 8.0 8.5. The dilational fault step is easier to rupture through than the compression fault step. The smallest widths of the fault step for the rupture arrest can be used as an indicator to judge the scale of the rupture termination of seismic faults. This is helpful for research on fault segmentation, as well as estimating the magnitude of potential earthquakes, and is thus of significance for the assessment of seismic risks.

  12. Morphological characteristics associated with rupture risk of multiple intracranial aneurysms.

    Science.gov (United States)

    Wang, Guang-Xian; Liu, Lan-Lan; Wen, Li; Cao, Yun-Xing; Pei, Yu-Chun; Zhang, Dong

    2017-10-01

    To identify the morphological parameters that are related to intracranial aneurysms (IAs) rupture using a case-control model. A total of 107 patients with multiple IAs and aneurysmal subarachnoid hemorrhage between August 2011 and February 2017 were enrolled in this study. Characteristics of IAs location, shape, neck width, perpendicular height, depth, maximum size, flow angle, parent vessel diameter (PVD), aspect ratio (AR) and size ratio (SR) were evaluated using CT angiography. Multiple logistic regression analysis was used to identify the independent risk factors associated with IAs rupture. Receiver operating characteristic curve analysis was performed on the final model, and the optimal thresholds were obtained. IAs located in the internal carotid artery (ICA) was associated with a negative risk of rupture, whereas AR, SR1 (height/PVD) and SR2 (depth/PVD) were associated with increased risk of rupture. When SR was calculated differently, the odds ratio values of these factors were also different. The receiver operating characteristic curve showed that AR, SR1 and SR2 had cut-off values of 1.01, 1.48 and 1.40, respectively. SR3 (maximum size/PVD) was not associated with IAs rupture. IAs located in the ICA are associated with a negative risk of rupture, while high AR (>1.01), SR1 (>1.48) or SR2 (>1.40) are risk factors for multiple IAs rupture. Copyright © 2017 Hainan Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  13. Patient Assessment of Constipation Quality of Life Questionnaire: Translation, Cultural Adaptation, Reliability, and Validity of the Persian Version.

    Science.gov (United States)

    Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan

    2018-05-01

    The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.

  14. Reliability-based fatigue life estimation of shear riveted connections considering dependency of rivet hole failures

    Directory of Open Access Journals (Sweden)

    Leonetti* Davide

    2018-01-01

    Full Text Available Standards and guidelines for the fatigue design of riveted connections make use of a stress range-endurance (S-N curve based on the net section stress range regardless of the number and the position of the rivets. Almost all tests on which S-N curves are based, are performed with a minimum number of rivets. However, the number of rivets in a row is expected to increase the fail-safe behaviour of the connection, whereas the number of rows is supposed to decrease the theoretical stress concentration at the critical locations, and hence these aspects are not considered in the S-N curves. This paper presents a numerical model predicting the fatigue life of riveted connections by performing a system reliability analysis on a double cover plated riveted butt joint. The connection is considered in three geometries, with different number of rivets in a row and different number of rows. The stress state in the connection is evaluated using a finite element model in which the friction coefficient and the clamping force in the rivets are considered in a deterministic manner. The probability of failure is evaluated for the main plate, and fatigue failure is assumed to be originating at the sides of the rivet holes, the critical locations, or hot-spots. The notch stress approach is applied to assess the fatigue life, considered to be a stochastic quantity. Unlike other system reliability models available in the literature, the evaluation of the probability of failure takes into account the stochastic dependence between the failures at each critical location modelled as a parallel system, which means considering the change of the state of stress in the connection when a ligament between two rivets fails. A sensitivity study is performed to evaluate the effect of the pretension in the rivet and the friction coefficient on the fatigue life.

  15. Trivial trauma and delayed rupture of a normal spleen: a case report

    Directory of Open Access Journals (Sweden)

    Sowers Nicholas

    2011-12-01

    Full Text Available Abstract Introduction Although a majority of splenic ruptures present acutely with a known mechanism of injury, a minority of patients present days to weeks following trauma with a delayed rupture. Also uncommon is the atraumatic rupture, the vast majority of which occur in patients with underlying splenic pathology. A handful of cases of apparently spontaneous rupture of a normal spleen are reported; however, there is debate about whether these actually represent delayed ruptures following a history of trauma that is not elicited. Although a few cases of delayed rupture of the spleen following trivial trauma have been reported, the majority of these present evidence of an underlying disease process. We found only two such cases that documented a normal spleen and three cases where underlying splenic pathology was not reported. We review the literature and discuss the phenomenon of delayed rupture of the normal spleen following trivial trauma. Case presentation A 27-year-old Caucasian man with no underlying splenic pathology presented with splenic rupture one week after playfully wrestling with his partner. The patient did not present at the time of the injury and only recalled it upon repeated questioning after computed tomography diagnosis. Conclusions This case lends support to the theory that the normal spleen can rupture some time after trivial trauma, which seems like a more plausible explanation than rupture without cause. However, given the dearth of similar reports in the literature, the possibility remains that the association we have observed is not causational.

  16. Ruptured Tendons in Anabolic-Androgenic Steroid Users: A Cross-Sectional Cohort Study.

    Science.gov (United States)

    Kanayama, Gen; DeLuca, James; Meehan, William P; Hudson, James I; Isaacs, Stephanie; Baggish, Aaron; Weiner, Rory; Micheli, Lyle; Pope, Harrison G

    2015-11-01

    Accumulating case reports have described tendon rupture in men who use anabolic-androgenic steroids (AAS). However, no controlled study has assessed the history of tendon rupture in a large cohort of AAS users and comparison nonusers. Men reporting long-term AAS abuse would report an elevated lifetime incidence of tendon rupture compared with non-AAS-using bodybuilders. Cohort study; Level of evidence, 3. Medical histories were obtained from 142 experienced male bodybuilders aged 35 to 55 years recruited in the course of 2 studies. Of these men, 88 reported at least 2 years of cumulative lifetime AAS use, and 54 reported no history of AAS use. In men reporting a history of tendon rupture, the circumstances of the injury, prodromal symptoms, concomitant drug or alcohol use, and details of current and lifetime AAS use (if applicable) were recorded. Surgical records were obtained for most participants. Nineteen (22%) of the AAS users, but only 3 (6%) of the nonusers, reported at least 1 lifetime tendon rupture. The hazard ratio for a first ruptured tendon in AAS users versus nonusers was 9.0 (95% CI, 2.5-32.3; P weightlifting, with the majority occurring during other sports activities. Eight (26%) ruptures followed prodromal symptoms of nonspecific pain in the region. Virtually all ruptures were treated surgically, with complete or near-complete ultimate restoration of function. AAS abusers, compared with otherwise similar bodybuilders, showed a markedly increased risk of tendon ruptures, particularly upper-body tendon rupture. © 2015 The Author(s).

  17. Computing broadband accelerograms using kinematic rupture modeling

    International Nuclear Information System (INIS)

    Ruiz Paredes, J.A.

    2007-05-01

    In order to make the broadband kinematic rupture modeling more realistic with respect to dynamic modeling, physical constraints are added to the rupture parameters. To improve the slip velocity function (SVF) modeling, an evolution of the k -2 source model is proposed, which consists to decompose the slip as a sum of sub-events by band of k. This model yields to SVF close to the solution proposed by Kostrov for a crack, while preserving the spectral characteristics of the radiated wave field, i.e. a w 2 model with spectral amplitudes at high frequency scaled to the coefficient of directivity C d . To better control the directivity effects, a composite source description is combined with a scaling law defining the extent of the nucleation area for each sub-event. The resulting model allows to reduce the apparent coefficient of directivity to a fraction of C d , as well as to reproduce the standard deviation of the new empirical attenuation relationships proposed for Japan. To make source models more realistic, a variable rupture velocity in agreement with the physics of the rupture must be considered. The followed approach that is based on an analytical relation between the fracture energy, the slip and the rupture velocity, leads to higher values of the peak ground acceleration in the vicinity of the fault. Finally, to better account for the interaction of the wave field with the geological medium, a semi-empirical methodology is developed combining a composite source model with empirical Green functions, and is applied to the Yamaguchi, M w 5.9 earthquake. The modeled synthetics reproduce satisfactorily well the observed main characteristics of ground motions. (author)

  18. One stage resection of spontaneous rupture of hepatocellular carcinoma in the triangular ligament with diaphragm invasion: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Park Kwang-Kuk

    2012-09-01

    Full Text Available Abstract A spontaneous rupture of hepatocellular carcinoma (HCC can lead to extensive hemorrhage and is a rare but life-threatening event. A 58-year-old male patient with no history of trauma presented at our institution with severe epigastric pain and abdominal distension for 6 h. His blood pressure was a 60/40 mmHg, and pulse rate was 132/min. Abdominal contrast enhanced computed tomography (CT imaging revealed a ruptured mass under the left diaphragm and fluid collection in the upper abdomen, flanks and pelvic cavity. Exploratory laparotomy confirmed the presence of an active bleeding tumor in the triangular ligament invading into the diaphragm. The tumor was resected with an appropriate diaphragm margin. The resected tumor was 5 cm in diameter and pathologically identified as hepatocellular carcinoma with a negative surgical margin. This case report shows that ruptured hepatocellular carcinoma should be considered in the differential diagnosis of non-traumatic hemoperitoneum. And it is necessary to set a surgical plan for unpredictable HCC rupture with direct diaphragm invasion.

  19. Three-Dimensional Dynamic Rupture in Brittle Solids and the Volumetric Strain Criterion

    Science.gov (United States)

    Uenishi, K.; Yamachi, H.

    2017-12-01

    As pointed out by Uenishi (2016 AGU Fall Meeting), source dynamics of ordinary earthquakes is often studied in the framework of 3D rupture in brittle solids but our knowledge of mechanics of actual 3D rupture is limited. Typically, criteria derived from 1D frictional observations of sliding materials or post-failure behavior of solids are applied in seismic simulations, and although mode-I cracks are frequently encountered in earthquake-induced ground failures, rupture in tension is in most cases ignored. Even when it is included in analyses, the classical maximum principal tensile stress rupture criterion is repeatedly used. Our recent basic experiments of dynamic rupture of spherical or cylindrical monolithic brittle solids by applying high-voltage electric discharge impulses or impact loads have indicated generation of surprisingly simple and often flat rupture surfaces in 3D specimens even without the initial existence of planes of weakness. However, at the same time, the snapshots taken by a high-speed digital video camera have shown rather complicated histories of rupture development in these 3D solid materials, which seem to be difficult to be explained by, for example, the maximum principal stress criterion. Instead, a (tensile) volumetric strain criterion where the volumetric strain (dilatation or the first invariant of the strain tensor) is a decisive parameter for rupture seems more effective in computationally reproducing the multi-directionally propagating waves and rupture. In this study, we try to show the connection between this volumetric strain criterion and other classical rupture criteria or physical parameters employed in continuum mechanics, and indicate that the criterion has, to some degree, physical meanings. First, we mathematically illustrate that the criterion is equivalent to a criterion based on the mean normal stress, a crucial parameter in plasticity. Then, we mention the relation between the volumetric strain criterion and the

  20. Pancreatic rupture in four cats with high-rise syndrome.

    Science.gov (United States)

    Liehmann, Lea M; Dörner, Judith; Hittmair, Katharina M; Schwendenwein, Ilse; Reifinger, Martin; Dupré, Gilles

    2012-02-01

    Pancreatic trauma and rupture are rare after feline high-rise syndrome; however, should it happen, pancreatic enzymes will leak into the abdominal cavity and may cause pancreatic autodigestion and fatty tissue saponification. If not diagnosed and treated, it can ultimately lead to multiorgan failure and death. In this case series, 700 records of high-rise syndrome cats that presented between April 2001 and May 2006 were analysed, and four cats with pancreatic rupture were identified. Clinical signs, diagnosis using ultrasonography and lipase activity in blood and abdominal effusion, and treatment modalities are reported. Three cats underwent surgical abdominal exploration, one cat was euthanased. Rupture of the left pancreatic limb was confirmed in all cases. Two of the operated cats survived to date. High-rise syndrome can lead to abdominal trauma, including pancreatic rupture. A prompt diagnosis and surgical treatment should be considered.

  1. 24. MPA-seminar: safety and reliability of plant technology with special emphasis on integrity and life management. Vol. 2. Papers 28-63

    International Nuclear Information System (INIS)

    1999-01-01

    The second volume is dedicated to the safety and reliability of plant technology with special emphasis on the integrity and life management. The following topics are discussed: 1. Integrity of vessels, pipes and components. 2. Fracture mechanics. 3. Measures for the extension of service life, and 4. Online Monitoring. All 30 contributions are separately analyzed for this database. (orig.)

  2. Spontaneous atraumatic extensor pollicis longus rupture in the nonrheumatoid population.

    Science.gov (United States)

    Rada, Erin M; Shridharani, Sachin M; Lifchez, Scott D

    2013-01-01

    Extensor pollicis longus (EPL) tendon rupture is a well-described phenomenon in patients with rheumatoid arthritis. Mechanisms of EPL tendon rupture in the nonrheumatoid population have also been described and include traumatic rupture, repetitive motion strain, and steroid injection into the tendon. The operative records for patients undergoing extensor pollicis longus reconstruction by the senior author were reviewed. Patients with a history of trauma to the wrist or inflammatory arthropathy were excluded. We identified 3 patients who presented with spontaneous EPL tendon rupture. These patients reported no risk factors (as listed earlier) or inciting event. All 3 patients had some exposure to local steroids but this exposure was not at the site of subsequent tendon rupture. All patients were operatively repaired and went on to full recovery of EPL function. In patients with sudden loss of extension of the thumb interphalangeal joint, a thorough history of steroid exposure including local steroid exposure remote to the affected EPL tendon may be relevant.

  3. Dynamic earthquake rupture simulations on nonplanar faults embedded in 3D geometrically complex, heterogeneous elastic solids

    Energy Technology Data Exchange (ETDEWEB)

    Duru, Kenneth, E-mail: kduru@stanford.edu [Department of Geophysics, Stanford University, Stanford, CA (United States); Dunham, Eric M. [Department of Geophysics, Stanford University, Stanford, CA (United States); Institute for Computational and Mathematical Engineering, Stanford University, Stanford, CA (United States)

    2016-01-15

    Dynamic propagation of shear ruptures on a frictional interface in an elastic solid is a useful idealization of natural earthquakes. The conditions relating discontinuities in particle velocities across fault zones and tractions acting on the fault are often expressed as nonlinear friction laws. The corresponding initial boundary value problems are both numerically and computationally challenging. In addition, seismic waves generated by earthquake ruptures must be propagated for many wavelengths away from the fault. Therefore, reliable and efficient numerical simulations require both provably stable and high order accurate numerical methods. We present a high order accurate finite difference method for: a) enforcing nonlinear friction laws, in a consistent and provably stable manner, suitable for efficient explicit time integration; b) dynamic propagation of earthquake ruptures along nonplanar faults; and c) accurate propagation of seismic waves in heterogeneous media with free surface topography. We solve the first order form of the 3D elastic wave equation on a boundary-conforming curvilinear mesh, in terms of particle velocities and stresses that are collocated in space and time, using summation-by-parts (SBP) finite difference operators in space. Boundary and interface conditions are imposed weakly using penalties. By deriving semi-discrete energy estimates analogous to the continuous energy estimates we prove numerical stability. The finite difference stencils used in this paper are sixth order accurate in the interior and third order accurate close to the boundaries. However, the method is applicable to any spatial operator with a diagonal norm satisfying the SBP property. Time stepping is performed with a 4th order accurate explicit low storage Runge–Kutta scheme, thus yielding a globally fourth order accurate method in both space and time. We show numerical simulations on band limited self-similar fractal faults revealing the complexity of rupture

  4. Pressure tube rupture in a closed tank

    International Nuclear Information System (INIS)

    Khater, H.A.; Hadaller, G.I.; Stern, F.

    1985-06-01

    A study has been prepared on the feasibility of conducting pressure tube/calandria tube rupture tests in a closed tank, simulating a scaled-down calandria vessel. The study includes: i) a review of previous work, ii) an analytical investigation of the scaling problem of the calandria vessel and relevant in-core structures, iii) selection of a method for initiating pressure tube/calandria tube rupture, iv) a set of specifications for the test assembly, v) general arrangement drawings, vi) a proposal for a test matrix, vii) a survey and evaluation of existing facilities which could provide the required high pressure, temperature and fluid inventory, and viii) a cost estimate for the detailed design and construction, instrumentation, data acquisition and reduction, testing and reporting. The study concludes that it is both technically and practically feasible to conduct pressure tube rupture tests in a closed tank

  5. Bladder rupture caused by postpartum urinary retention.

    Science.gov (United States)

    Dueñas-García, Omar Felipe; Rico, Hugo; Gorbea-Sanchez, Viridiana; Herrerias-Canedo, Tomas

    2008-08-01

    Postpartum bladder rupture is an uncommon surgical emergency and a diagnostic challenge. A primigravida delivered a healthy newborn without complications at 39.4 weeks of gestation. The patient was admitted 80 hours postpartum with abdominal pain, oliguria, hematuria, and pain that worsened during the previous 4 hours. An inserted Foley catheter drained only a small amount of urine, and serum creatinine was elevated (3.5 mg/dL). A laparotomy was performed and revealed a 10-cm hole in the urinary bladder. The bladder was repaired and the patient was discharged 15 days after surgery. The follow-up cystoscopy revealed adequate healing of the bladder. Urinary retention can lead to serious complications, including bladder rupture. Postpartum bladder rupture due to urinary retention should be ruled out if there is a history of abdominal pain, oliguria, and elevated of serum creatinine.

  6. Creep rupture behavior of unidirectional advanced composites

    Science.gov (United States)

    Yeow, Y. T.

    1980-01-01

    A 'material modeling' methodology for predicting the creep rupture behavior of unidirectional advanced composites is proposed. In this approach the parameters (obtained from short-term tests) required to make the predictions are the three principal creep compliance master curves and their corresponding quasi-static strengths tested at room temperature (22 C). Using these parameters in conjunction with a failure criterion, creep rupture envelopes can be generated for any combination of in-plane loading conditions and ambient temperature. The analysis was validated experimentally for one composite system, the T300/934 graphite-epoxy system. This was done by performing short-term creep tests (to generate the principal creep compliance master curves with the time-temperature superposition principle) and relatively long-term creep rupture tensile tests of off-axis specimens at 180 C. Good to reasonable agreement between experimental and analytical results is observed.

  7. Viscoelastic characterization of carbon fiber-epoxy composites by creep and creep rupture tests

    International Nuclear Information System (INIS)

    Farina, Luis Claudio

    2009-01-01

    One of the main requirements for the use of fiber-reinforced polymer matrix composites in structural applications is the evaluation of their behavior during service life. The warranties of the integrity of these structural components demand a study of the time dependent behavior of these materials due to viscoelastic response of the polymeric matrix and of the countless possibilities of design configurations. In the present study, creep and creep rupture test in stress were performed in specimens of unidirectional carbon fiber-reinforced epoxy composites with fibers orientations of 60 degree and 90 degree, at temperatures of 25 and 70 degree C. The aim is the viscoelastic characterization of the material through the creep curves to some levels of constant tension during periods of 1000 h, the attainment of the creep rupture envelope by the creep rupture curves and the determination of the transition of the linear for non-linear behavior through isochronous curves. In addition, comparisons of creep compliance curves with a viscoelastic behavior prediction model based on Schapery equation were also performed. For the test, a modification was verified in the behavior of the material, regarding the resistance, stiffness and deformation, demonstrating that these properties were affected for the time and tension level, especially in work temperature above the ambient. The prediction model was capable to represent the creep behavior, however the determination of the equations terms should be considered, besides the variation of these with the applied tension and the elapsed time of test. (author)

  8. Spontaneous Rupture of Hepatocellular Carcinoma in a Young Patient with Fatal Outcome

    Directory of Open Access Journals (Sweden)

    David F. Pinal-García

    2018-01-01

    Full Text Available Spontaneous rupture of hepatocellular carcinoma (HCC is a potentially life-threatening complication. Diagnosis may be difficult, particularly in the absence of known liver cirrhosis or tumor. A 20-year-old male patient presented with progressive abdominal pain and shock. His past medical history was uneventful. Anemia, acute renal failure, and abnormal liver function test were demonstrated. Mild hepatomegaly, perihepatic and flank fluid, and multiple hypodense liver lesions suggestive of intrahepatic metastases or multifocal HCC were revealed by computed tomography. Two actively bleeding liver tumors and multiple tumors in a noncirrhotic liver were found. Hemostatic suture and perihepatic packing were performed. The patient remained in critical condition, with a fatal outcome 48 h later. Histopathologic analysis reported HCC and absence of cirrhotic changes. HCC spontaneous rupture incidence is reported between 2.3 and 26%. Median age is 65 years. No liver cirrhosis is found in one-third of patients, with a median age of 51 years. Sudden onset of abdominal pain and shock is observed in the majority of cases. An accurate preoperative diagnosis improves to 75% with ultrasound and computed tomography. Besides hemodynamic stabilization, there is no general agreement on the best treatment option. Transarterial embolization, surgical perihepatic packing, suture plication, and hepatic artery ligation are useful methods of hemostasis in unstable patients. Mortality has been reported from 16.5 to 100%. The histopathologic finding of HCC in a noncirrhotic liver represents a less frequent presentation. A case of spontaneous rupture of HCC carcinoma and a noncirrhotic liver in a young patient is herein reported.

  9. [Delayed rupture of the spleen in a multiply injured patient].

    Science.gov (United States)

    Lică, I; Venter, M D; Mehic, R; Marian, R; Ionescu, G

    1997-01-01

    The authors present a case of delayed rupture of the spleen in a polytraumatised patient. This entity was defined as a late occurrence of signs and symptoms attributed to splenic injury not detected by diagnostic computed tomographic scanning during the initial examination. The mechanisms in which the delayed rupture of the spleen occurs are discussed and the conclusion is that the delayed rupture of the spleen represent a real clinical entity.

  10. Rupture of a Solid Pseudopapillary Neoplasm of the pancreas

    Directory of Open Access Journals (Sweden)

    Barbara Rampersad

    2018-03-01

    Full Text Available An acute presentation of a spontaneously ruptured Solid-Pseudopapillary Neoplasm (SPN in an 8 year old female is discussed with a review of the world literature. Our literature search revealed 15 other cases of ruptured SPN and with this case the total is now 16. Notably, 12 patients were 16 years of age or less at presentation as in our case. Although rupture of a SPN is rarely reported it appears to be more probable in the pediatric patient. Additionally, larger tumor size and trauma may be contributing factors.

  11. Open splenectomy for Varicella zoster induced spontaneous splenic rupture

    Directory of Open Access Journals (Sweden)

    Mark Christopher Sykes

    2018-01-01

    Conclusion: Atraumatic splenic rupture should be considered as an important differential in those presenting with abdominal pain and peritonism without a history of preceding trauma. Haematological and infectious diagnoses should be sought to identify causation for the splenic rupture.

  12. Rapid Estimates of Rupture Extent for Large Earthquakes Using Aftershocks

    Science.gov (United States)

    Polet, J.; Thio, H. K.; Kremer, M.

    2009-12-01

    The spatial distribution of aftershocks is closely linked to the rupture extent of the mainshock that preceded them and a rapid analysis of aftershock patterns therefore has potential for use in near real-time estimates of earthquake impact. The correlation between aftershocks and slip distribution has frequently been used to estimate the fault dimensions of large historic earthquakes for which no, or insufficient, waveform data is available. With the advent of earthquake inversions that use seismic waveforms and geodetic data to constrain the slip distribution, the study of aftershocks has recently been largely focused on enhancing our understanding of the underlying mechanisms in a broader earthquake mechanics/dynamics framework. However, in a near real-time earthquake monitoring environment, in which aftershocks of large earthquakes are routinely detected and located, these data may also be effective in determining a fast estimate of the mainshock rupture area, which would aid in the rapid assessment of the impact of the earthquake. We have analyzed a considerable number of large recent earthquakes and their aftershock sequences and have developed an effective algorithm that determines the rupture extent of a mainshock from its aftershock distribution, in a fully automatic manner. The algorithm automatically removes outliers by spatial binning, and subsequently determines the best fitting “strike” of the rupture and its length by projecting the aftershock epicenters onto a set of lines that cross the mainshock epicenter with incremental azimuths. For strike-slip or large dip-slip events, for which the surface projection of the rupture is recti-linear, the calculated strike correlates well with the strike of the fault and the corresponding length, determined from the distribution of aftershocks projected onto the line, agrees well with the rupture length. In the case of a smaller dip-slip rupture with an aspect ratio closer to 1, the procedure gives a measure

  13. Plantar Fascia Rupture: Ultrasound to Facilitate Recognition.

    Science.gov (United States)

    Servey, Jessica T; Jonas, Christopher

    2018-01-01

    Plantar fascia rupture in the absence of previous diagnosis of plantar fasciitis, corticosteroid injection, or injury is a rare occurrence with only 7 case reports in the literature since 1978. This is a case of spontaneous plantar fascia rupture in a 38-year-old active-duty US military member with current considerations in musculoskeletal ultrasound, other radiologic imaging, treatment, and followup of this diagnosis. © Copyright 2018 by the American Board of Family Medicine.

  14. Spontaneous splenic rupture. Radiological findings in three cases

    International Nuclear Information System (INIS)

    Arenal, F.; Barrera, J.; Merino, S.; Pedrosa, C. S.

    1999-01-01

    Spontaneous splenic rupture not associated with previous trauma is an uncommon disease. It can appear in the course of multiple systemic diseases or over a normal splenic architecture, which is even more infrequent. An early diagnosis results mandatory, since it is a potentially fatal disease if it is not promptly diagnosed and managed. We present three cases of spontaneous splenic rupture (two sub capsular hematomas opened to peritoneum and a rupture of splenic parenchyma). One patient had infectious mononucleosis, other was in the acute phase of a chronic pancreatitis and the third one had a normal splenic architecture. We emphasize the importance of CT in the early diagnosis of this entity. (Author) 21 refs

  15. Uterine rupture: socio-demographic aspects, etiology and therapy at the University Clinic of Gynecology and Obstetrics of the National Donka Hospital in Conakry University Hospital, Guinea.

    Science.gov (United States)

    Diallo, M H; Baldé, I S; Mamy, M N; Diallo, B S; Baldé, O; Barry, A B; Keita, N

    2017-08-01

    Uterine rupture is an obstetric catastrophe that has become rare in developed countries. In developing countries, including Guinea, however, it remains a major concern of obstetricians. The objectives of this work were to calculate the frequency of uterine rupture in our département, describe the women's social and demographic characteristics, identify factors predisposing them to uterine rupture, describe its treatment, and assess maternal and fetal prognosis. Data for this descriptive study were collected in 2 phases, with a retrospective review of files covering the 3-year period from April 1, 2011, to March 31, 2014, followed by prospective data collection for the 6-month period from April 1 to September 30, 2014. This study of uterine rupture took place at the maternity unit of Donka National Hospital (CHU Conakry). We identified 98 cases of uterine rupture among 26 827 births, for a frequency of 0.36%. The women's mean age was 28.4 years (range: 16-43 years). The socio-demographic profile of the women admitted for uterine rupture was that of a housewife (50%), with two or three previous deliveries (41.84%), and who had no prenatal care (58.17%). Most of the ruptures took place in birthing centers, outlying maternity units, or during the journey to reach our reference department (87.16%). Most uterine ruptures were iatrogenic (69.38%) and occurred on an non cicatriciel uterus (62.24%). The rupture was most often complete. Most surgical treatment was conservative, by hysterorrhaphy (80.61%). Four women died, for a lethality rate of 4.80%. Almost all women were admitted without signs of fetal life. The role of uterine rupture in the obstetric activity in this service requires joint and urgent action by all stakeholders in the health system to combat this catastrophic complication that is evidence of a poor quality of obstetric care.

  16. Antibiotics after preterm premature rupture of the membranes.

    Science.gov (United States)

    Singh, Katherine; Mercer, Brian

    2011-06-01

    Preterm premature rupture of the membranes remains a common cause of preterm deliveries and neonatal morbidities. The goal of this study is to review the evidence with regard to the antibiotic treatment after preterm premature rupture of the membranes, long-term outcomes related to antibiotic treatment, and possible complications with treatment. Future research goals are also discussed.

  17. Aneurysmal rupture of the costo-cervical trunk in a patient with neurofibromatosis type 1: A case report.

    Science.gov (United States)

    Hoonjan, Bhupinder; Thayur, Nagendra; Abu-Own, Abdusalam

    2014-01-01

    Rupture of blood vessels associated with neurofibromatosis type 1 (NF-1) is a rare but life threatening complication. We report the first case of an aneurysmal rupture from the costocervical trunk in a NF-1 patient treated by endovascular embolisation. A 43 year-old gentleman with a past medical history of NF-1 presented with sudden onset left sided neck swelling. A computed tomography (CT) revealed a large cervical haematoma, which was causing airway compromise, requiring the patient to be intubated. Percutaneous embolisation of the bleeding vessel from the costo-cervical trunk was performed with successful haemostasis and no immediate complications. A repeat CT scan showed a reduction in the original cervical haematoma. However, six days post embolisation, the patient arrested with complete whiteout of the left hemithorax. CT angiography is the gold standard for diagnosis of an aneurysmal rupture in NF-1 patients, and percutaneous embolisation is the preferred modality in patients who are haemodynamically stable due to arterial fragility and high intra operative mortality rates. The increasing haemothorax could be explained by the original cervical haematoma draining down into the pleural space, or the possibility of a new second bleed. This is the first reported episode of bleeding from the costocervical trunk in NF-1 patients. Ruptured aneurysms require urgent CT angiography, if haemodynamically stable, and further input from the vascular surgeons and vascular radiologists. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Aneurysmal rupture of the costo-cervical trunk in a patient with neurofibromatosis type 1: A case report☆

    Science.gov (United States)

    Hoonjan, Bhupinder; Thayur, Nagendra; Abu-Own, Abdusalam

    2013-01-01

    INTRODUCTION Rupture of blood vessels associated with neurofibromatosis type 1 (NF-1) is a rare but life threatening complication. We report the first case of an aneurysmal rupture from the costocervical trunk in a NF-1 patient treated by endovascular embolisation. PRESENTATION OF CASE A 43 year-old gentleman with a past medical history of NF-1 presented with sudden onset left sided neck swelling. A computed tomography (CT) revealed a large cervical haematoma, which was causing airway compromise, requiring the patient to be intubated. Percutaneous embolisation of the bleeding vessel from the costo-cervical trunk was performed with successful haemostasis and no immediate complications. A repeat CT scan showed a reduction in the original cervical haematoma. However, six days post embolisation, the patient arrested with complete whiteout of the left hemithorax. DISCUSSION CT angiography is the gold standard for diagnosis of an aneurysmal rupture in NF-1 patients, and percutaneous embolisation is the preferred modality in patients who are haemodynamically stable due to arterial fragility and high intra operative mortality rates. The increasing haemothorax could be explained by the original cervical haematoma draining down into the pleural space, or the possibility of a new second bleed. CONCLUSION This is the first reported episode of bleeding from the costocervical trunk in NF-1 patients. Ruptured aneurysms require urgent CT angiography, if haemodynamically stable, and further input from the vascular surgeons and vascular radiologists. PMID:24463561

  19. Identification of fall risk predictors in daily life measurements: gait characteristics' reliability and association with self-reported fall history.

    Science.gov (United States)

    Rispens, Sietse M; van Schooten, Kimberley S; Pijnappels, Mirjam; Daffertshofer, Andreas; Beek, Peter J; van Dieën, Jaap H

    2015-01-01

    Background. Gait characteristics extracted from trunk accelerations during daily life locomotion are complementary to questionnaire- or laboratory-based gait and balance assessments and may help to improve fall risk prediction. Objective. The aim of this study was to identify gait characteristics that are associated with self-reported fall history and that can be reliably assessed based on ambulatory data collected during a single week. Methods. We analyzed 2 weeks of trunk acceleration data (DynaPort MoveMonitor, McRoberts) collected among 113 older adults (age range, 65-97 years). During episodes of locomotion, various gait characteristics were determined, including local dynamic stability, interstride variability, and several spectral features. For each characteristic, we performed a negative binomial regression analysis with the participants' self-reported number of falls in the preceding year as outcome. Reliability of gait characteristics was assessed in terms of intraclass correlations between both measurement weeks. Results. The percentages of spectral power below 0.7 Hz along the vertical and anteroposterior axes and below 10 Hz along the mediolateral axis, as well as local dynamic stability, local dynamic stability per stride, gait smoothness, and the amplitude and slope of the dominant frequency along the vertical axis, were associated with the number of falls in the preceding year and could be reliably assessed (all P 0.75). Conclusions. Daily life gait characteristics are associated with fall history in older adults and can be reliably estimated from a week of ambulatory trunk acceleration measurements. © The Author(s) 2014.

  20. Reliability Assessment of Concrete Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Middleton, C. R.

    This paper is partly based on research performed for the Highways Agency, London, UK under the project DPU/9/44 "Revision of Bridge Assessment Rules Based on Whole Life Performance: concrete bridges". It contains the details of a methodology which can be used to generate Whole Life (WL) reliability...... profiles. These WL reliability profiles may be used to establish revised rules for concrete bridges. This paper is to some extend based on Thoft-Christensen et. al. [1996], Thoft-Christensen [1996] et. al. and Thoft-Christensen [1996]....

  1. Shared and Distinct Rupture Discriminants of Small and Large Intracranial Aneurysms.

    Science.gov (United States)

    Varble, Nicole; Tutino, Vincent M; Yu, Jihnhee; Sonig, Ashish; Siddiqui, Adnan H; Davies, Jason M; Meng, Hui

    2018-04-01

    Many ruptured intracranial aneurysms (IAs) are small. Clinical presentations suggest that small and large IAs could have different phenotypes. It is unknown if small and large IAs have different characteristics that discriminate rupture. We analyzed morphological, hemodynamic, and clinical parameters of 413 retrospectively collected IAs (training cohort; 102 ruptured IAs). Hierarchal cluster analysis was performed to determine a size cutoff to dichotomize the IA population into small and large IAs. We applied multivariate logistic regression to build rupture discrimination models for small IAs, large IAs, and an aggregation of all IAs. We validated the ability of these 3 models to predict rupture status in a second, independently collected cohort of 129 IAs (testing cohort; 14 ruptured IAs). Hierarchal cluster analysis in the training cohort confirmed that small and large IAs are best separated at 5 mm based on morphological and hemodynamic features (area under the curve=0.81). For small IAs (IAs (area under the curve=0.84; 95% confidence interval, 0.78-0.88), whereas for large IAs (≥5 mm), the model included undulation index, low wall shear stress, previous subarachnoid hemorrhage, and IA location (area under the curve=0.87; 95% confidence interval, 0.82-0.93). The model for the aggregated training cohort retained all the parameters in the size-dichotomized models. Results in the testing cohort showed that the size-dichotomized rupture discrimination model had higher sensitivity (64% versus 29%) and accuracy (77% versus 74%), marginally higher area under the curve (0.75; 95% confidence interval, 0.61-0.88 versus 0.67; 95% confidence interval, 0.52-0.82), and similar specificity (78% versus 80%) compared with the aggregate-based model. Small (IAs have different hemodynamic and clinical, but not morphological, rupture discriminants. Size-dichotomized rupture discrimination models performed better than the aggregate model. © 2018 American Heart Association, Inc.

  2. Intrinsic, Transitional, and Extrinsic Morphological Factors Associated With Rupture of Intracranial Aneurysms.

    Science.gov (United States)

    Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose

    2015-09-01

    As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.

  3. Association of the route of blood flow channel through an intraluminal thrombus with the abdominal aortic aneurysm rupture in imaging diagnostics

    International Nuclear Information System (INIS)

    Wiernicki, I.; Gutowski, P.; Kownacki, L.; Polanowski, L.; Gorecka-Szyld, B.; Cyrylowski, L.

    2004-01-01

    The location of the abdominal aortic aneurysm (AAA) rupture probably influences the patient's morbidity and mortality. No reliable predictors for time and site of the rupture have been found to date. An opinion that intraluminal, parietal thrombus (PT) may play a protective role against the rupture predominates in recent reports. The aim of our study was to evaluate a route of blood flow channel (BFC) through intraluminal PT in AAA. In this prospective study, the thrombus morphology was evaluated in 103 patients with AAA, divided into three groups according to the aneurysm size: group 1 - patients with AAA 30 - 39 mm in maximal diameter, group 2: 40 - 49 mm, and group 3: more than 49 mm. All AAAs were examined with Doppler ultrasound, computed tomography, and magnetic resonance imaging. Anterior, medial, and posterior BFC was defined on the basis of calculated ratio of anterior wall PT thickness to posterior wall PT thickness. Anterior BFC predominates in AAA in group 1 - 39%, while its frequency in group 3 was 21%. Posterior BFC was significantly more frequent in group 3 - 67% than in group 1 - 24%. Both differences were statistically significant (p = 0.03). PT thickness increases in direct proportion to the size of AAA, and with this increase BFC in the thrombus most frequently shifts backward. A lack of PT or its trace may indicate a site of potential rupture of the weakened wall. Patients with AAA and a parietal route of BFC in the thrombus are of higher risk of rupture despite small aneurysm size. In qualification for surgery, the morphology of the thrombus should be considered, in addition to the maximal diameter of AAA. (author)

  4. Ectopic pregnancy with tubal rupture: an analysis of 80 cases

    International Nuclear Information System (INIS)

    Ashfaq, S.; Aziz, S.; Hasan, M.; Sultan, S.; Irfan, S.M.

    2017-01-01

    Ectopic pregnancy (EP) is a major problem in obstetrics as there is evidence of increasing incidence throughout the world. It is an important cause of maternal morbidity and mortality. In Pakistan, the care seeking behaviour among female is limited that makes female vulnerable to die due to complication of ectopic pregnancy. The aim of this study is to determine the frequency of tubal rupture in ectopic pregnancy in Pakistani patients. Method: In this cross-sectional study data pertaining to age, gestational age, parity and duration of presenting symptoms were collected and analysed. Result: 80 patients were diagnosed to have ectopic pregnancy. The frequency of tubal rupture was 91.25%. It is encountered significantly more often in women with age of 26 years. More tubal rupture is found in patient with low parity, in which the frequency of tubal rupture is up to 100% and decrease up to 78.6% with increasing parity up to four. Furthermore, it is noted that increase in gestational age from 8 weeks to 10 weeks caused an increase in frequency of tubal rupture from 80 to 100% respectively. It is also noted that earlier the patient presents the lesser is the frequency of tubal rupture, as compared to late presentation beyond 3-4 days which make frequency up to 95%. Conclusion: Tubal rupture is still common cause of maternal morbidity and mortality, and is still a major challenge in gynaecological practice. Creating awareness amongst midwives and GPs regarding early diagnosis can contribute to decrease the mortality, morbidity and fertility loss related to EP. (author)

  5. Some aspects of the interaction between systems- and structural reliability

    International Nuclear Information System (INIS)

    Schueller, G.K.; Schmitt, W.

    1979-01-01

    The purpose of this paper is to study the interaction between systems- and structural reliability analysis with reference to the design of structural components of LWR. Presently the evaluation of systems reliability is carried out apart from structural reliability analysis. Moreover, two basically different methodologies are used for analysis. While in systems analysis the simplified binary approach is still generally accepted, in structural reliability one has to resort to more sophisticated procedures to obtain realistic results. The interactive effect may be illustrated as follows: For example, the integrity of the primary circuit interacts with the integrity of the containment structure. This means that the probability of occurrence of the pipe rupture which may cause a LOCA and consequently leads to a build-up of temperature and pressure within the containment affects directly its structural reliability. The piping system, particularly the primary piping, in turn interacts with the protective system, which is part of the safety system. This piping structure is also subjected to various operational loading conditions. In a numerical example dealing with leakage probabilities of pipes it is shown how methods of structural reliability may be used to gain more insight in the estimation of failure rates of system components. (orig.)

  6. Ruptured popliteal cyst diagnosed by ultrasound before evaluation for deep vein thrombosis.

    Science.gov (United States)

    Kim, Joon Sung; Lim, Seong Hoon; Hong, Bo Young; Park, So Young

    2014-12-01

    Most popliteal cysts are asymptomatic. However, cysts may rupture, resulting in pain and swelling of the leg that could also arise from other diseases, including deep vein thrombosis, lymphedema, cellulitis, and tear of a muscle or tendon. Therefore, it is difficult to diagnose a ruptured popliteal cyst based on only a patient's history and physical examination. Musculoskeletal ultrasound has been regarded as a diagnostic tool for ruptured popliteal cyst. Here, we describe a patient who was rapidly diagnosed as ruptured popliteal cyst by ultrasonography. Therefore, ultrasound could be used to distinguish a ruptured popliteal cyst from other diseases in patients with painful swollen legs before evaluation for deep vein thrombosis.

  7. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  8. The Behçet's Disease Quality of Life: Reliability and Validity of the Korean Version

    Science.gov (United States)

    Yi, Sang Won; Kim, Ji-Hae; Lim, Ki-Young; Bang, Dongsik; Lee, Sungnack

    2008-01-01

    Purpose The Behçet's Disease Quality of Life (BD-QoL) is a BD-specific measure developed in the UK. The aim of this study was to adapt the BD-QoL for use in Korea. Patients and Methods The translation was based on the guidelines for cross-cultural adaptation. A total of 201 Korean patients with BD participated in this study. To evaluate the psychometric properties, internal consistency and test-retest reliability were used. Factor analysis was performed to examine the construct validity. To provide further evidence for validity, the correlation of BD-QoL with the Clinical Activity Form for Korean Patients with BD (BDCAF-K) and the Center for Epidemiologic Studies-Depression (CES-D) scales was assessed. Results The Korean version had high internal consistency (Cronbach's alpha, 0.93) and test-retest reliability (r = 0.835). Factor analysis of the questionnaire revealed one interpretable factor as a general health-related quality of life factor. The Korean version significantly correlated with scores of CES-D (r = 0.749, p= 0.000), self-rating scale of well-being over the past 28 days (r = 0.446, p= 0.000), and BDCAF-K score (r = 0.502, p = 0.000). Conclusion Adaptation of the BD-QoL for use in Korea was successful. Together with the BDCAF-K, it may be a valuable tool for assessing the influence of interventions in BD patients and outcome in clinical trials. PMID:18972588

  9. Analysis of independent failure assumptions on postulated secondary high energy line ruptures

    International Nuclear Information System (INIS)

    Hollingsworth, S.D.

    1977-01-01

    Postulated ruptures of the main steam piping in pressurized water reactors result in large amounts of steam being removed from the secondary system. Since the energy removal rate could be many times that of nominal design power, there may be a rapid cooldown of the primary coolant system and a positive addition of reactivity to the reactor core. The Westinghouse protection system design concept incorporates features that trip the reactor, isolate the main steamlines and provide for automatic alternate shutdown capability in the form of boric acid solution injection into the primary coolant system. At the most limiting time in life (end of life) the reactivity calculated to be inserted by the cooldown is sufficient to overcome the shutdown margin predicted to be available from control rods with the most reactive rod in the fully withdrawn position. Because the boron injected into the core may be delayed due to system responses, there is potential that the reactor core could return critical and return to power. The extremely adverse radial power distributions caused by the fully withdrawn control rod causes localized high power densities that could lead to reduced heat transfer capability (DNB). Because of the large amount of stored energy in the reactor coolant system at full power, the cooldown and subsequent return to power is more severe when calculated from a shutdown, hot zero power condition. It is shown that the protection system design has large margins to protect against adverse core effects following a steamline rupture

  10. Spontaneous Achilles tendon rupture in alkaptonuria

    Directory of Open Access Journals (Sweden)

    Omar A. Alajoulin

    2015-12-01

    Full Text Available Alkaptonuria (AKU is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA. Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis, early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  11. Spontaneous Achilles tendon rupture in alkaptonuria.

    Science.gov (United States)

    Alajoulin, Omar A; Alsbou, Mohammed S; Ja'afreh, Somayya O; Kalbouneh, Heba M

    2015-12-01

    Alkaptonuria (AKU) is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA). Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis), early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  12. Morphological and clinical risk factors for posterior communicating artery aneurysm rupture.

    Science.gov (United States)

    Matsukawa, Hidetoshi; Fujii, Motoharu; Akaike, Gensuke; Uemura, Akihiro; Takahashi, Osamu; Niimi, Yasunari; Shinoda, Masaki

    2014-01-01

    Recent studies have shown that posterior circulation aneurysms, specifically posterior communicating artery (PCoA) aneurysms, are more likely to rupture than other aneurysms. To date, few studies have investigated the factors contributing to PCoA aneurysm rupture. The authors aimed to identify morphological and clinical characteristics predisposing to PCoA aneurysm rupture. The authors retrospectively reviewed 134 consecutive patients with PCoA aneurysms managed at their facility between July 2003 and December 2012. The authors divided patients into groups of those with aneurysmal rupture (n = 39) and without aneurysmal rupture (n = 95) and compared morphological and clinical characteristics. Morphological characteristics were mainly evaluated by 3D CT angiography and included diameter of arteries (anterior cerebral artery, middle cerebral artery, and internal carotid artery), size of the aneurysm, dome-to-neck ratio, neck direction of the aneurysmal dome around the PCoA (medial, lateral, superior, inferior, and posterior), aneurysm bleb formation, whether the PCoA was fetal type, and the existence of other intracranial unruptured aneurysm(s). Patients with ruptured PCoA aneurysms were significantly younger (a higher proportion were PCoA aneurysms showed a lateral direction of the aneurysmal dome around the PCoA, had bleb formation, and the aneurysm was > 7 mm in diameter and/or the dome-to-neck ratio was > 2.0. Multivariate logistic regression analysis showed age PCoA (OR 6.7, p = 0.0001), and bleb formation (OR 11, p PCoA aneurysm rupture. The present results demonstrated that lateral projection of a PCoA aneurysm may be related to rupture.

  13. Ruptured liver abscess: Analysis of 50 cases

    Directory of Open Access Journals (Sweden)

    Mohit Bhatia

    2017-01-01

    Full Text Available Background: Liver abscess (pyogenic and amebic is frequently encountered clinical condition; however, it can result in lethal outcome if there is a delay in diagnosis and treatment. Despite modalities to diagnose the condition early, still ruptured liver abscess presents with a common cause of acute abdomen in surgical emergency. In developing countries, ruptured liver abscess is a common cause of mortality. For contained abscess, nonsurgical options are considered; however, for ruptured liver abscess, surgical intervention is considered necessary. Materials and Methods: This was a retrospective study carried in Safdarjung hospital, New Delhi, between 2015 and 2016. All patients with ruptured liver abscess (clear signs of peritonitis were included in this study, and those patients having other causes of peritonitis were excluded. A preformed protocol for management was followed for all the patients, and various parameters contributing to the illness and its prognosis were evaluated and assessed. Results: Out of the fifty patients assessed, male patients were mainly affected (86%. The most affected age group was 31–40 years (64% followed by 41–50 years (22%. Right hypochondrium pain was the most common presenting complaint. Nine patients (18% had presented with signs of toxemia. Only right lobe of the liver was affected the most in 44 patients (88%. Escherichia coli was the most common organism isolated in our study in 19 patients (38%. A total of 19 patients (38% had diabetes in our study and total of 13 patients had mortality in our study. Conclusion: Ruptured liver abscess most commonly involves the right lobe of the liver. Males are affected far higher than the females; probable cause believed to be higher alcohol consumption. Most common affected age group falls between 30 and 60 years of age. If prompt treatment is started in time, mortality involved with it is evitable.

  14. Extracorporeal membrane oxygenation (ECMO as salvage treatment for pulmonary Echinococcus granulosus infection with acute cyst rupture

    Directory of Open Access Journals (Sweden)

    Sören L. Becker

    2017-11-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO has been used successfully for the treatment of patients with respiratory failure due to severe infections. Although rare, parasites can also cause severe pulmonary disease. Tapeworms of the genus Echinococcus give rise to the development of cystic structures in the liver, lungs, and other organs. Acute cyst rupture leads to potentially life-threatening infection, and affected patients may deteriorate rapidly. The case of a young woman from Bulgaria who was admitted to hospital with severe dyspnoea, progressive chest pain, and haemoptysis is described. Computed tomography of the chest was pathognomonic for cystic echinococcosis with acute cyst rupture. Following deterioration on mechanical ventilation, she was cannulated for veno-venous ECMO. The patient’s condition improved considerably, and she was weaned successfully from ECMO and mechanical ventilation. Following lobectomy of the affected left lower lobe, the patient was discharged home in good condition. This appears to be the first report of the successful use of ECMO as salvage treatment for a severe manifestation of a helminthic disease. Due to recent migration to Western Europe, the number of patients presenting with respiratory failure due to pulmonary echinococcosis with cyst rupture is likely to increase. Keywords: Extracorporeal membrane oxygenation (ECMO, Infection, Echinococcosis, Echinococcus granulosus, Hydatid disease, Infection

  15. Reproducibility and Reliability of the Quality of Life Questionnaire in Patients With Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Rita Simone Lopes Moreira

    2016-03-01

    Full Text Available Abstract Background: Studies have shown the impact of atrial fibrillation (AF on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1, which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2, which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36 to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC. Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40 had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

  16. Special equipment for processing can-rupture measurements; Equipement specialise de traitement des mesures de rupture de gaines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J.; Phalippou, J.; Dumont, D.; Viellard, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Recent installations for detecting can-rupture in nuclear reactors use, in the measurement processing section, a digital computer, either completely or partially. The reliability of the system is limited by that of the computer, which represents a common point for the processing of data from the detector. In order to satisfy the demands imposed by safety considerations for the operation of the equipment it is necessary to consider the possibility of installing a second computer in certain cases. The use of a computer involves the presence as interface between the detection equipment and the computer itself, of sealers operating as integrators for the pulses produced by the detector. By adding a certain number of circuits to these sealers, it is possible to carry out the work now demanded of the computer, as far as the calculation is concerned. This reasoning has led us to a so-called 'decentralized' solution involving the construction of specialized equipment in the region of the prospector itself. We believe that this solution, apart from the reliability point of view, has definite economic advantages. In our solution, the common point in the processing of the data is now situated not in the zone of the production of results but further down, in the printing out of these results. Even in the case of an incident at the common point, the results are produced, exposed and compared to the alarm thresholds. In the case of a breakdown of the specialized equipment, the results from this prospector are no longer available but the others continue to operate. It seems that this solution is more reliable than that employing universal computers. By using an interchangeable drawer system (MULTIBLOC) it is possible to replace rapidly any of the specialized equipment which breaks down. The systematic use of integrated circuits (TTL) ensures an increased reliability of the equipment. (author) [French] Les installations recentes de detection de rupture de gaines

  17. Using Rasch Analysis to Evaluate the Reliability and Validity of the Swallowing Quality of Life Questionnaire: An Item Response Theory Approach.

    Science.gov (United States)

    Cordier, Reinie; Speyer, Renée; Schindler, Antonio; Michou, Emilia; Heijnen, Bas Joris; Baijens, Laura; Karaduman, Ayşe; Swan, Katina; Clavé, Pere; Joosten, Annette Veronica

    2018-02-01

    The Swallowing Quality of Life questionnaire (SWAL-QOL) is widely used clinically and in research to evaluate quality of life related to swallowing difficulties. It has been described as a valid and reliable tool, but was developed and tested using classic test theory. This study describes the reliability and validity of the SWAL-QOL using item response theory (IRT; Rasch analysis). SWAL-QOL data were gathered from 507 participants at risk of oropharyngeal dysphagia (OD) across four European countries. OD was confirmed in 75.7% of participants via videofluoroscopy and/or fiberoptic endoscopic evaluation, or a clinical diagnosis based on meeting selected criteria. Patients with esophageal dysphagia were excluded. Data were analysed using Rasch analysis. Item and person reliability was good for all the items combined. However, person reliability was poor for 8 subscales and item reliability was poor for one subscale. Eight subscales exhibited poor person separation and two exhibited poor item separation. Overall item and person fit statistics were acceptable. However, at an individual item fit level results indicated unpredictable item responses for 28 items, and item redundancy for 10 items. The item-person dimensionality map confirmed these findings. Results from the overall Rasch model fit and Principal Component Analysis were suggestive of a second dimension. For all the items combined, none of the item categories were 'category', 'threshold' or 'step' disordered; however, all subscales demonstrated category disordered functioning. Findings suggest an urgent need to further investigate the underlying structure of the SWAL-QOL and its psychometric characteristics using IRT.

  18. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  19. Nontraumatic spontaneous rupture of the kidney : etiology and CT findings

    International Nuclear Information System (INIS)

    Heo, Tae Haeng; Jeon, Hae Jeong; Shin, Hyun Joon; Kim, Bo Hyun; Cho, Kyoung Sik; Kim, Young Hwa; Kim, Seung Hyup; Park, Churl Min

    1997-01-01

    To evaluate the usefulness of CT scanning in determining the etiology of spontaneous rupture of the kidney We retrospectively analyzed the CT findings of spontaneous rupture of the kidney in eleven patients, Four were male and seven were female, and they were aged between 20 and 71 (mean, 46.6) years. Both pre- and post-contrast enhanced CT scanning was performed in all patients. Spontaneous renal rupture was induced in seven cases by neoplasms (three angiomyolipomas, three renal cell carcinomas, and one metastatic choriocarcinoma), in three cases by infection or inflammation (acute and chronic pyelonephritis, and renal abscess), and in one, by renal cyst. Common CT findings of rupture of the kidney were the accumulation of high density fluid in the perirenal and anterior pararenal space, and inhomogeneous irregular low density of renal parenchyma and the rupture site. Angiomyolipoma showed fat and an angiomatous component in the lesion, while acute and chronic pyelonephrities revealed thinning of the renal parenchyma and an irregular renal outline. Renal cell carcinoma showed a dense soft tissue mass in the parenchyma. Well-defined, round low-density lesions were noted in the case of renal cyst and renal abscess. CT is very useful in diagnosing and determining the etiology of non-traumatic spontaneous rupture of the kidney and plays an important role in the evaluation of emergency cases

  20. The Reliability of Turkish "Basic Life Support" and "Cardiac Massage" Videos Uploaded to Websites.

    Science.gov (United States)

    Elicabuk, Hayri; Yaylacı, Serpil; Yilmaz, Atakan; Hatipoglu, Celile; Kaya, F Gokhan; Serinken, Mustafa

    2016-02-01

    In this study, the reliability of Turkish cardiac massage and Basic Life Support (BLS) videos, which have already been downloaded from three website such as YouTube, Google, Yahoo following the publication of 2010 cardiopulmonary resuscitation (CPR) guideline and their suitability to the same guideline were researched. The videos uploaded to the three web-site to search videos on internet were queried by using the keywords "cardiac massage" and "basic life support". Videos that had been uploaded between January 2011 and July 2014 were analyzed and scored by two experienced emergency specialists. A total of 1126 videos were obtained. 1029 of the videos (91.4%) were excluded by researchers. 97 videos were detected to accord with study criteria. Despite most of the videos were found on Google website by keywords, the enormous part of videos proper to criteria were sourced from YouTube website (n=65, 67.0%). One fourth of the videos (24.7%) were observed to not be suitable for 2010 CPR guideline. AED usage was mentioned slightly in the videos (14.4%). Median score of the videos is 5 (IQR: 4-6). The rate and scores of the videos uploaded by official institution or association were significantly higher than others (p=0.007 and 0.006, respectively). Moreover, scores of the videos compatible with guidelines uploaded by official institution or association and medical personal were also found higher (p=0.001). Eventually, all the data obtained in this study support that Turkish videos were not reliable on the subject of BLS and cardiac massage. It is promising that videos with high follow-up rates also have been scored higher.