WorldWideScience

Sample records for rupture ct-guided intervention

  1. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  2. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  3. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  4. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  5. CT guided interventional therapy for hypertensive cerebral hemorrhage

    International Nuclear Information System (INIS)

    Lin Bo; Duan Bing

    2009-01-01

    Objective: To discuss the curative effect of CT-guided puncture and drainage in treating hypertensive cerebral hemorrhage. Methods: Adjusting the suitable point and direction of puncture according to the form and size of the haematoma and patient's status, the haematoma was eliminated by minimally invasive puncture and drainage guided under CT layer image in 40 cases of hypertensive cerebral hemorrhage. Results: Modality rate of treatment group was 12.5% (5/40), and is much lower than control group, which was 45% (13/30) (P<0.01). When asscess the Activities of Daily Living (ADL) after 6 months follow-up, the ADL1-ADL3 scale in treatment group was 27 cases (70%), and was much higher than that in control group, which was 29.4% (5/17), (P < 0.05). Conclusion: Minimal invasive therapy of cerebral hemorrhage has great superiority in elimination most part of the hematoma such as simple, accurate location, low cost, safe and effective, and is worthy of recommendation clinically. (authors)

  6. Percutaneous CT-guided interventional procedures in musculoskeletal system (our experience)

    Energy Technology Data Exchange (ETDEWEB)

    Thanos, Loukas E-mail: loutharad@yahoo.com; Mylona, Sophia; Kalioras, Vasilios; Pomoni, Maria; Batakis, Nikolaos

    2004-06-01

    Percutaneous interventional procedures include a broad spectrum of minimal invasive techniques, which are a useful diagnostic and therapeutic tool. In this study we present our experience in CT-guided percutaneous musculoskeletal biopsies, drainages of musculoskeletal abscesses, facet and sacroiliac joint injection and radiofrequency thermal ablation of painful metastases or osteoid osteomas.

  7. Prospective evaluation of the radiologist's hand dose in CT-guided interventions

    International Nuclear Information System (INIS)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J.; Kropf, S.; Nekolla, E.A.; Wieners, G.

    2013-01-01

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  8. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    Science.gov (United States)

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  9. CT-guided interventions in children; Computertomografisch gesteuerte Interventionen bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2007-06-15

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  10. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  11. PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan

    Energy Technology Data Exchange (ETDEWEB)

    Wong, K.; Rahill, J.; Cleary, K. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Petrillo, S.; Earl-Graef, D. [Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Banovac, F.; Levy, E. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Shekhar, R. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    2007-06-15

    Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

  12. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  13. Application of Real-Time 3D Navigation System in CT-Guided Percutaneous Interventional Procedures: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Priya Bhattacharji

    2017-01-01

    Full Text Available Introduction. To evaluate the accuracy of a quantitative 3D navigation system for CT-guided interventional procedures in a two-part study. Materials and Methods. Twenty-two procedures were performed in abdominal and thoracic phantoms. Accuracies of the 3D anatomy map registration and navigation were evaluated. Time used for the navigated procedures was recorded. In the IRB approved clinical evaluation, 21 patients scheduled for CT-guided thoracic and hepatic biopsy and ablations were recruited. CT-guided procedures were performed without following the 3D navigation display. Accuracy of navigation as well as workflow fitness of the system was evaluated. Results. In phantoms, the average 3D anatomy map registration error was 1.79 mm. The average navigated needle placement accuracy for one-pass and two-pass procedures, respectively, was 2.0±0.7 mm and 2.8±1.1 mm in the liver and 2.7±1.7 mm and 3.0±1.4 mm in the lung. The average accuracy of the 3D navigation system in human subjects was 4.6 mm ± 3.1 for all procedures. The system fits the existing workflow of CT-guided interventions with minimum impact. Conclusion. A 3D navigation system can be performed along the existing workflow and has the potential to navigate precision needle placement in CT-guided interventional procedures.

  14. Prospective evaluation of the radiologist's hand dose in CT-guided interventions; Prospektive Evaluation der Handdosis des Radiologen im Rahmen von CT-gestuetzten Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Kropf, S. [Magdeburg Univ. (Germany). Dept. of Biometry and Medical Informatics; Nekolla, E.A. [The Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Radiation Protection and Health; Wieners, G. [Charite CVC, Berlin (Germany). Dept. of Radiology

    2013-11-15

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  15. A gesture-controlled projection display for CT-guided interventions.

    Science.gov (United States)

    Mewes, A; Saalfeld, P; Riabikin, O; Skalej, M; Hansen, C

    2016-01-01

    The interaction with interventional imaging systems within a sterile environment is a challenging task for physicians. Direct physician-machine interaction during an intervention is rather limited because of sterility and workspace restrictions. We present a gesture-controlled projection display that enables a direct and natural physician-machine interaction during computed tomography (CT)-based interventions. Therefore, a graphical user interface is projected on a radiation shield located in front of the physician. Hand gestures in front of this display are captured and classified using a leap motion controller. We propose a gesture set to control basic functions of intervention software such as gestures for 2D image exploration, 3D object manipulation and selection. Our methods were evaluated in a clinically oriented user study with 12 participants. The results of the performed user study confirm that the display and the underlying interaction concept are accepted by clinical users. The recognition of the gestures is robust, although there is potential for improvements. The gesture training times are less than 10 min, but vary heavily between the participants of the study. The developed gestures are connected logically to the intervention software and intuitive to use. The proposed gesture-controlled projection display counters current thinking, namely it gives the radiologist complete control of the intervention software. It opens new possibilities for direct physician-machine interaction during CT-based interventions and is well suited to become an integral part of future interventional suites.

  16. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  17. Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures

    International Nuclear Information System (INIS)

    Pereira, M. F.; Alves, J. G.; Sarmento, S.; Santos, J. A. M.; Sousa, M. J.; Gouvea, M.; Oliveira, A. D.; Cardoso, J. V.; Santos, L. M.

    2011-01-01

    A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The H p (10) dose values received above the lead apron (ranged 0.20-0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. H p (0.07) values to the hand (ranged 36.30-0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy. (authors)

  18. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  19. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    International Nuclear Information System (INIS)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H.; Wiemann, Christian; Guenther, Rolf W.; Kyriakou, Yiannis; Kalender, Willi A.; Schmitz-Rode, Thomas

    2010-01-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  20. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Nagel, Markus; Elfring, Robert; Schmitz-Rode, Thomas; Gronloh, Nina; Guenther, Rolf W.; Mahnken, Andreas H.

    2009-01-01

    An electromagnetic-based tracking and navigation system was evaluated for interventional radiology. The electromagnetic tracking system (CAPPA IRAD EMT, CASinnovations, Erlangen, Germany) was used for real-time monitoring of punctures of the lumbar facet joints and intervertebral disks in a spine phantom, three pig cadavers and three anaesthesized pigs. Therefore, pre-interventional computed tomography (CT) datasets were transferred to the navigation system and puncture trajectories were planned. A coaxial needle was advanced along the trajectories while the position of the needle tip was monitored in real time. After puncture tracts were marked with pieces of wire another CT examination was performed and distances between wires and anatomical targets were measured. Performing punctures of the facet joints mean needle positioning errors were 0.4 ± 0.8 mm in the spine phantom, 2.8 ± 2.1 mm ex vivo and 3.0 ± 2.0 mm in vivo with mean length of the puncture tract of 54.0 ± 10.4 mm (phantom), 51.6 ± 12.6 mm (ex vivo) and 50.9 ± 17.6 mm (in vivo). At first attempt, intervertebral discs were successfully punctured in 15/15 in the phantom study, in 12/15 in the ex-vivo study and 14/15 in the in-vivo study, respectively. Immobilization of the patient and optimal positioning of the field generator are essential to achieve a high accuracy of needle placement in a clinical CT setting. (orig.)

  1. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H. [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Wiemann, Christian; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Kyriakou, Yiannis; Kalender, Willi A. [Friedrich-Alexander University of Erlangen-Nuremberg, Institute for Medical Physics, Erlangen (Germany); Schmitz-Rode, Thomas [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany)

    2010-11-15

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 {+-} 0.9 mm (phantom) and 0.6 {+-} 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 {+-} 1.2 mm (phantom) and 0.5 {+-} 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 {+-} 0.9 mm and 1.0 {+-} 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 {+-} 17.3 s vs. 20.8 {+-} 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 {+-} 5.1 s vs. 28.6 {+-} 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 {+-} 9.0 s vs. 23.6 {+-} 7.2 s, p = 0.001) and IVD punctures (43.9 {+-} 16.1 s vs. 31.1 {+-} 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  2. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments.

    Science.gov (United States)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Wiemann, Christian; Kyriakou, Yiannis; Kalender, Willi A; Günther, Rolf W; Schmitz-Rode, Thomas; Mahnken, Andreas H

    2010-11-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures.

  3. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    International Nuclear Information System (INIS)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo; Anile, Marco; Venuta, Federico; Vitolo, Domenico; Saba, Luca; Longo, Flavia

    2015-01-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  4. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    Energy Technology Data Exchange (ETDEWEB)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Radiology - Sapienza, Rome (Italy); Anile, Marco; Venuta, Federico [University of Rome, Department of Thoracic Surgery - Sapienza, Rome (Italy); Vitolo, Domenico [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Pathology - Sapienza, Rome (Italy); Saba, Luca [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Monserrato (Italy); Longo, Flavia [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Oncology - Sapienza, Rome (Italy)

    2015-05-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  5. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  6. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  7. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems

    International Nuclear Information System (INIS)

    Schulz, T.; Roettger, S.; Bahner-Heyne, E.J.; Kluge, G.

    2009-01-01

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  8. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  9. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  10. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  11. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Gevargez, A.; Schirp, S.; Braun, M. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); Groenemeyer, D. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); EFMT Development and Research Center for Microtherapy, Bochum (Germany)

    2002-06-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  12. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    International Nuclear Information System (INIS)

    Gevargez, A.; Schirp, S.; Braun, M.; Groenemeyer, D.

    2002-01-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  13. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  14. Interventional treatment of un-ruptured tubal pregnancy

    International Nuclear Information System (INIS)

    Shan Hong; Ma Zhuang; Jiang Zaibo; Yan Ying; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Chen Hanwei

    2000-01-01

    Objective: To discuss some concept about interventional treatment of tubal pregnancy. Methods: The procedure of trans-vaginal tubal intra-gestational SAC injection (IGSI) or percutaneous intra-utero-arterial infusion (IUAI) was selected for treatment of 40 patients with un-ruptured tubal pregnancy. Methotrexate (MTX), Rosch-Thurmoud fallopian tube catheterization set, and the general angiographic catheters of 4.1-5.0 F were used for the procedure. Ultrasound and urine beta-hCG were the main indexes monitoring the therapeutic effects. Results: 12 of 40 patients underwent a total of 15 IGSI. Of these, 3 patients required a second injection; 28 of 40 cases were treated with IUAI. The total successful rate of termination of ectopic pregnancy was 97.5%, the mean resolution time for reduction of beta-hCG concentration was 11.7 days (range 4-28), the range of menstruation recovery time was 7-45 days. Conclusion: The interventional therapy for tubal pregnancy will be more widely applied, on the basis of a better understanding about the pathology, characteristics of embryonic sac development and blood supply, the regular change of concentration of serum and urine hCG in tubal pregnancy

  15. Anterolateral papillary muscle rupture after intervention of the right coronary artery.

    Science.gov (United States)

    Morris, Liam; Desai, Anand; Akkus, Nuri Ilker

    2015-11-01

    Rupture of the anterolateral papillary muscle following a right coronary artery occlusion is extremely rare, and when complicated by a right ventricular infarction, can be fatal. The literature on optimal management of this complication is limited. We present an unusual case of anterolateral papillary muscle rupture following intervention of the right coronary artery. Published by Elsevier España.

  16. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  17. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F.; Bretschneider, T.; Hartwig, T.; Disch, A.C.

    2014-01-01

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  18. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  19. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  20. Rupture

    CERN Multimedia

    Association du personnel

    2006-01-01

    Our Director-General is indifferent to the tradition of concertation foreseen in our statutes and is "culturally" unable to associate the Staff Association with problem-solving in staff matters. He drags his heels as long as possible before entering into negotiations, presents "often misleading" solutions at the last minute which he only accepts to change once a power struggle has been established. Faced with this rupture and despite its commitment to concertation between gentlemen. The results of the poll in which the staff is invited to participate this week. We therefore need your support to state our claims to the Governing Bodies. The Staff Association proposes a new medium of communication and thus hopes to show that it is ready for future negotiations. The pages devoted to the Staff Association are presented in a more informative, reactive and factual manner and in line with the evolution of the social situation at CERN. We want to establish strong and continuous ties between the members of CERN and ou...

  1. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  2. Pericardial Tamponade Following CT-Guided Lung Biopsy

    International Nuclear Information System (INIS)

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-01-01

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  3. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  4. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    International Nuclear Information System (INIS)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A.; Akbar, M.

    2016-01-01

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  5. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    Energy Technology Data Exchange (ETDEWEB)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A. [Heidelberg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology; Akbar, M. [Heidelberg Univ. (Germany). Dept. of Orthopaedic Surgery and Rehabilitation Medicine

    2016-12-15

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  6. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  7. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  8. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  9. Automatic path proposal computation for CT-guided percutaneous liver biopsy.

    Science.gov (United States)

    Helck, A; Schumann, C; Aumann, J; Thierfelder, K; Strobl, F F; Braunagel, M; Niethammer, M; Clevert, D A; Hoffmann, R T; Reiser, M; Sandner, T; Trumm, C

    2016-12-01

    To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.

  10. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  11. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  12. Interventional therapy for acute myocardial infarction associated with postinfarction ventricular septal rupture: report of 6 cases

    International Nuclear Information System (INIS)

    Zhou Ling; Xie Dujiang; Dong Jing; Wu Chengquan; Tian Nailiang; Li Xiaobo; Wang Rong; Chen Shaoliang

    2014-01-01

    Objective: To evaluate the curative effect of interventional therapy in treating acute myocardial infarction (AMI) associated with postinfarction ventricular septal rupture (VSR). Methods: Transcatheter closure was performed in 6 patients with VSR which was caused by AMI. Percutaneous coronary intervention (PCI) was also carried out according to patient's clinical condition. The results were analyzed. Results: The interval between the occurrence of VSR and the performance of transcatheter closure ranged from 3 to 30 days. Of the six patients, transcatheter closure failed in two, who died from cardiogenic shock during hospitalization. The remaining 4 patients experienced a successful transcatheter closure procedure, and their cardiac function was improved during the follow-up period lasting for 0.5-4 years. Conclusion: Interventional transcatheter treatment is safe and feasible for acute myocardial infarction complicated by postinfarction ventricular septal rupture. (authors)

  13. CT-guided percutaneous treatment of solitary pyogenic splenic abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Pombo, F. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Suarez, I. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Marini, M. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Arrojo, L. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Echaniz, A. [Dept. of Internal Medicine, Hospital Juan Canalejo, La Coruna (Spain)

    1991-08-01

    Six patients with solitary pyogenic splenic abscesses treated by CT-guided percutaneous drainage (by catheter or needle), are presented. There were 3 unilocular, purely intrasplenic abscesses and 3 complex lesions with loculations and perisplenic involvement. Percutaneous drainage and intravenous antibiotics were curative in 4 patients. In the other 2, who had multiloculated abscesses, despite initially successful drainage, splenectomy was performed because of intractable left upper quadrant pain in one case and persistent fever and drainage of pus after 30 days in the other. These patients also developed large, sterile left pleural effusions. Solitary pyogenic splenic abscesses - particularly if uniloculated - can be effectively treated by CT-guided percutaneous drainage. (orig.)

  14. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  15. Simple and inexpensive method for CT-guided stereotaxy

    Energy Technology Data Exchange (ETDEWEB)

    Wester, K; Sortland, O; Hauglie-Hanssen, E

    1981-01-01

    A simple and inexpensive method for CT-guided stereotaxy is described. The method requires neither sophisticated computer programs nor additional stereotactic equipment, such as special head holders for the CT, and can be easily obtained without technical assistance. The method is designed to yield the vertical coordinates.

  16. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  17. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems; Vergleich zweier Navigationshilfen fuer CT-gesteuerte Interventionen unter besonderer Beruecksichtigung der Nutzungseigenschaften der verwendeten Systeme

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, T. [Inst. fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Jena (Germany); Roettger, S. [Klinik fuer Nuklearmedizin, Medizinische Hochschule Hannover (Germany); Bahner-Heyne, E.J.; Kluge, G. [Inst. fuer Psychologie und Arbeitswissenschaft, FG Arbeits-, Ingenieur- und Organisationspsychologie, TU Berlin (Germany)

    2009-06-15

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  18. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  19. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  20. CT-guided intratumoral gene therapy in non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Heussel, C.P.; Thelen, M.; Schuler, M.; Huber, C.; Weymarn, A. von; Bongartz, G.; Rochlitz, C.

    1999-01-01

    The objective of this study was to prove the principle of CT-guided gene therapy by intratumoral injection of a tumor suppressor gene as an alternative treatment approach of incurable non-small-cell lung cancer. In a prospective clinical phase I trial six patients with non-small-cell lung cancer and a mutation of the tumor suppressor gene p53 were treated by CT-guided intratumoral gene therapy. Ten milliliters of a vector solution (replication-defective adenovirus with complete wild-type p53 cDNA) were injected under CT guidance. In four cases the vector solution was completely applied to the tumor center, whereas in two cases 2 ml aliquots were injected into different tumor areas. For the procedure the scan room had been approved as a biosafety cabinet. Gene transfer was assessed by reverse transcription and polymerase chain reaction in biopsy specimens obtained under CT guidance 24-48 h after therapy. Potential therapeutic efficacy was evaluated on day 28 after treatment using spiral CT. The CT-guided gene therapy was easily performed in all six patients without intervention-related complications. Besides flu-like symptoms, no significant adverse effects of gene therapy were noted. Three of the four patients with central injection exhibited gene transfer in the posttreatment biopsy. Gene transfer could not be proven in the two patients with multiple 2 ml injections. After 28 days, four of the six patients showed stable disease at the treated tumor site, whereas other tumor manifestations progressed. Computed tomography-guided injections are an adequate and easy-to-perform procedure for intratumoral gene therapy. (orig.)

  1. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  2. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  3. Spinal CT-guided injections. Clinical applications-limitations

    International Nuclear Information System (INIS)

    Stamatakis, V.; Vlachou, I.; Petrocheilou, G.; Safarika, V.; Geroukis, I.; Petinelli, A.; Stathopoulou, S.; Kokkinis, C.

    2012-01-01

    Full text: Introduction: Chronic spinal pain is an important health issue with serious social and financial consequences. Thus, application of minimal invasive procedures is a popular technique for immediate relief of pain. Objectives and tasks: Our purpose is to present CT guided intraspinal injection of pharmaceutical agents for the relief of persistent pain. Material and methods: Chronic localized or radicular spinal pain may be treated safely and efficiently with injection of various pharmaceutical agents (local anesthetic, opioid analgesic and steroids or combination of these). The possible sites of infiltration include: a) intervertebral joints (facets), b) sacroiliac joints, c)perineural infiltration of the affected nerve roots and d) the epidural space. We will mention the patients choice criteria (combination of clinical symptoms and specific pain evaluation questionnaire) as they are reported in the international bibliography. Finally, we will discuss the repeatability criteria of the method as well as its limitations. Results: CT-guided pharmaceutical agents injection for the relief of persistent spinal pain have an advantage against other methods because of the precision and safety that they offer to the localization and diagnosis of the pain cause. Conclusion: Small complications percentage and satisfactory results have made CT-guided spinal injections a popular technique for chronic back pain relief. In order to apply these techniques the good knowledge of the method, its possibilities and limitations is necessary

  4. Nursing care for patients with local recurrent rectal cancer after CT-guided 125I seed implantation therapy

    International Nuclear Information System (INIS)

    Yuan Li; Wei Fan; Ren Caifeng; Tu Mingmei; Qian Guixiang

    2010-01-01

    Objective: To discuss the nursing care strategy for patients with local recurrent rectal cancer who has been treated with CT-guided 125 I seed implantation therapy. Methods: Twenty patients with local recurrent rectal cancer received a series of nursing interventions, including comfort care and pain care. The clinical results were observed and analyzed. Results: The therapy was smoothly accomplished in all patients. The pain was remarkably relived and the anxiety was alleviated. No displacement of implanted 125 I seed occurred. Conclusion: For patients with local recurrent rectal cancer occurred after CT-guided 125 I seed implantation therapy, careful nursing can effectively relieve the pain and anxiety feeling,and the living quality can also be markedly improved. (authors)

  5. Bilateral CT-guided percutaneous cordotomy for cancer pain relief

    International Nuclear Information System (INIS)

    Yegul, I.; Erhan, E.

    2003-01-01

    AIM: CT-guided percutaneous cordotomy is a useful procedure for treating unilateral cancer pain, however, bilateral cordotomy can be required on some occasions. We evaluated the effectiveness and complications of bilateral cordotomy. MATERIALS AND METHODS: Two hundred and thirty-four patients who suffered from unilateral cancer pain underwent CT-guided percutaneous cordotomy. The procedure was repeated in 22 patients, and nine patients had bilateral cordotomy. Effectiveness and complications were recorded after each procedure. RESULTS: Of nine patents (three women and six men) having bilateral percutaneous cordotomy in our study, four patients had mirror pain after the first procedure. In the remaining five patients the contralateral pain was due to new pain sites. The pain scores before and after the first procedure were 9.3 (range 7-10) and 1.2 (range 0-3), respectively. After the first procedure complete or satisfactory pain relief was achieved in all patients. The duration between the two procedures ranged from 7-243 days (mean 59.8 days). The pain scores before and after the second procedure were 8.4 (range 5-10) and 1.6 (range 0-4), respectively. After the second procedure complete or satisfactory pain relief was reported in all patients. There were no complications in four patients. One patient developed transient motor deficit after the first procedure. Other complications (nausea/vomiting, headache, ipsilateral neck pain, postcordotomy dysesthesia) were mild and transient. CONCLUSION: CT-guided percutaneous cordotomy is a useful procedure for the treatment of severe unilateral cancer pain syndromes. The procedure can be repeated on the other side at least 1 week later. These results show that the success on the second side appears to be similar to the first side with low complication rate for both procedures

  6. Bilateral CT-guided percutaneous cordotomy for cancer pain relief

    Energy Technology Data Exchange (ETDEWEB)

    Yegul, I. E-mail: iyegul@med.ege.edu.tr; Erhan, E. E-mail: elvanerhan@yahoo.com

    2003-11-01

    AIM: CT-guided percutaneous cordotomy is a useful procedure for treating unilateral cancer pain, however, bilateral cordotomy can be required on some occasions. We evaluated the effectiveness and complications of bilateral cordotomy. MATERIALS AND METHODS: Two hundred and thirty-four patients who suffered from unilateral cancer pain underwent CT-guided percutaneous cordotomy. The procedure was repeated in 22 patients, and nine patients had bilateral cordotomy. Effectiveness and complications were recorded after each procedure. RESULTS: Of nine patents (three women and six men) having bilateral percutaneous cordotomy in our study, four patients had mirror pain after the first procedure. In the remaining five patients the contralateral pain was due to new pain sites. The pain scores before and after the first procedure were 9.3 (range 7-10) and 1.2 (range 0-3), respectively. After the first procedure complete or satisfactory pain relief was achieved in all patients. The duration between the two procedures ranged from 7-243 days (mean 59.8 days). The pain scores before and after the second procedure were 8.4 (range 5-10) and 1.6 (range 0-4), respectively. After the second procedure complete or satisfactory pain relief was reported in all patients. There were no complications in four patients. One patient developed transient motor deficit after the first procedure. Other complications (nausea/vomiting, headache, ipsilateral neck pain, postcordotomy dysesthesia) were mild and transient. CONCLUSION: CT-guided percutaneous cordotomy is a useful procedure for the treatment of severe unilateral cancer pain syndromes. The procedure can be repeated on the other side at least 1 week later. These results show that the success on the second side appears to be similar to the first side with low complication rate for both procedures.

  7. CT-guided conformal cryoablation for peripheral NSCLC: Initial experience

    International Nuclear Information System (INIS)

    Zhang, Xiao; Tian, Jinlin; Zhao, Lei; Wu, Bin; Kacher, Daniel S.; Ma, Xuyang; Liu, Shurong; Ren, Chao; Xiao, Yue-Yong

    2012-01-01

    Purpose: To study the feasibility of CT-guided and monitored percutaneous conformal cryoablation of Non-Small Cell Lung Cancer for patients who are not suitable for surgical resection. Materials and method: CT-guided percutaneous conformal cryoablation was performed on 46 patients with peripheral Non-Small Cell Lung Cancer. Patients with tumor sizes less than 3 cm in diameter were treated with double-needle clamping cryoablation, while the patients with 3–5 cm tumor sizes were treated with multiple-needle conformal cryoablation. CT was used to monitor the extent of cryoablation during the procedures. At month 1, 3, 6, 12, and 24 post-procedure, enhanced CT scans and/or PET-CT scans were performed to evaluate the impact of the therapy. Results: The average tumor CT values were 32 ± 10 HU and −21 ± 8 HU before and after cryoablation, respectively. The largest diameters of the lesions at month 1, 3, 6, 12, and 24 post-procedure were 2.63 ± 0.56 cm, 1.93 ± 0.51 cm, 1.55 ± 0.39 cm, 1.43 ± 0.40 cm, and 1.38 ± 0.38 cm, respectively, in patients with tumor diameter less than 3 cm, and 3.63 ± 0.39 cm, 2.98 ± 0.31 cm, 2.62 ± 0.32 cm, 2.54 ± 0.34 cm, and 2.56 ± 0.37 cm respectively in patients with the tumor diameters between 3 and 5 cm. At the 24th month, there were 36 cases of complete response (83.7%), 7 cases of partial response (16.3%), and no cases of stable disease or progressive disease. 3 patients died due to multiple metastases. Conclusion: CT-guided percutaneous conformal cryoablation is a safe, effective, and minimally invasive therapeutic method for peripheral lung cancer.

  8. CT guided stereotaxy based on scout view imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wester, K; Kjartansson, O; Bakke, S J

    1987-05-01

    A simple and inexpensive method for CT guided sterotaxy is described. The method requires no extra equipment in the interface between the computer tomograph and the stereotaxic frame, and could therefore easily be adopted in most neurosurgical units. With this method, information from the transaxial CT sections is transferred manually via the scout view image to the operation theater skull X-rays, and thereby to the stereotaxic frame. The method has proved to be sufficiently accurate for all current non-functional stereotaxic procedures in our department during 30 months of testing.

  9. CT guided stereotaxy based on scout view imaging

    International Nuclear Information System (INIS)

    Wester, K.; Kjartansson, O.; Bakke, S.J.; Rikshospitalet, Oslo

    1987-01-01

    A simple and inexpensive method for CT guided sterotaxy is described. The method requires no extra equipment in the interface between the computer tomograph and the stereotaxic frame, and could therefore easily be adopted in most neurosurgical units. With this method, information from the transaxial CT sections is transferred manually via the scout view image to the operation theater skull X-rays, and thereby to the stereotaxic frame. The method has proved to be sufficiently accurate for all current non-functional stereotaxic procedures in our department during 30 months of testing. (orig.)

  10. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  11. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  12. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Born, Christopher T. [Temple University Hospital/Temple Children' s Hospital, Temple Sports Medicine, Marlton, NJ (United States); Grudziak, Jan S. [Children' s Hospital of Pittsburgh, Department of Orthopedic Surgery, Pittsburgh, PA (United States); Towbin, Richard B.

    2004-12-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  13. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    International Nuclear Information System (INIS)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D.; Born, Christopher T.; Grudziak, Jan S.; Towbin, Richard B.

    2004-01-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  14. CT-guided suprascapular nerve blocks: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A. [Department of Medical Imaging, Victoria House Private Hospital, 316 Malvern Road, Prahran 3181, Melbourne, Victoria (Australia)

    2004-05-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean ({+-}SEM) pain score of 7.0 ({+-}0.4) to 3.5 ({+-}0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% ({+-}4.9, P<0.001) and 16.8% ({+-}4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  15. The results of CT-guided periradicular pain control

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Arlinghaus, J.

    1997-01-01

    The effectiveness of CT-guided periradicular pain therapy was studied. Material and method: 55 patients with lumbar and/or radicular pain were treated by periradicular injections of 40 ml triamcinolon, in some cases combined with injection of the facets of the lumbar vertebrae. 36 patients had chronic symptoms; in 7, these were acute, and 12 patients complained of renewed disc symptoms following previous disc surgery. Approximately 4 months after the conclusion of treatment, the patients were requested to complete a questionnaire giving information on the course and after-effects of treatment. The questionnaire was repeated after 5 months. Results: 55% of patients were free of symptoms or had had some improvement at the time of the questionnaire; 30% reported temporary improvement, and in 15% there was no change compared with the pre-treatment symptoms. At the time of the second questionnaire, the proportion of patients who had derived benefit from the treatment was somewhat lower. 49% reported that they were pain-free or improved, while temporary improvement was reported by 36% of patients. Conclusion: CT-guided periradicular pain therapy is a valuable procedure in patients in whom conservative measures prove ineffective, and when surgery is not indicated. However, only about half the treated patients maintain permanent improvement. (orig.) [de

  16. CT-guided suprascapular nerve blocks: a pilot study

    International Nuclear Information System (INIS)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A.

    2004-01-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean (±SEM) pain score of 7.0 (±0.4) to 3.5 (±0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% (±4.9, P<0.001) and 16.8% (±4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  17. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules.

    Science.gov (United States)

    Lendeckel, Derik; Kromrey, Marie-Luise; Ittermann, Till; Schäfer, Sophia; Mensel, Birger; Kühn, Jens-Peter

    2017-01-01

    Pneumothoraces are the most frequently occurring complications of CT-guided percutaneous transthoracic pulmonary biopsies (PTPB). The aim of this study was to evaluate the influence of pre-diagnostic lung emphysema on the incidence and extent of pneumothoraces and to establish a risk stratification for the evaluation of the pre-procedure complication probability. CT-guided PTPB of 100 pre-selected patients (mean age 67.1±12.8 years) were retrospectively enrolled from a single center database of 235 PTPB performed between 2012-2014. Patients were grouped according to pneumothorax appearance directly after PTPB (group I: without pneumothorax, n = 50; group II: with pneumothorax, n = 50). Group II was further divided according to post-interventional treatment (group IIa: chest tube placement, n = 24; group IIb: conservative therapy, n = 26). For each patient pre-diagnostic percentage of emphysema was quantified using CT density analysis. Emphysema stages were compared between groups using bivariate analyses and multinomial logistic regression analyses. Emphysema percentage was significantly associated with the occurrence of post-interventional pneumothorax (p = 0.006). Adjusted for potential confounders (age, gender, lesion size and length of interventional pathway) the study yielded an OR of 1.07 (p = 0.042). Absolute risk of pneumothorax increased from 43.4% at an emphysema rate of 5% to 73.8% at 25%. No differences could be seen in patients with pneumothorax between percentage of emphysema and mode of therapy (p = 0.721). The rate of lung emphysema is proportionally related to the incidence of pneumothorax after CT-guided PTPB and allows pre-interventional risk stratification. There is no association between stage of emphysema and post-interventional requirement of chest tube placement.

  18. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  19. CT-guided stereotactic evacuation of hypertensive intracerebral hematomas

    International Nuclear Information System (INIS)

    Hondo, Hideki

    1983-01-01

    Computerized tomography (CT) is now effective not only for definite diagnosis and location of intracerebral hematomas but also for coordination of the center of a hematoma. CT-guided stereotactic evacuation of hypertensive intracerebral hematoma was performed in 51 cases: 34 of basal ganglionic hematoma with or without ventricular perforation, 11 of subcortical hematoma, 3 of thalamic hematoma and 3 of cerebellar hematoma. Three dimensional CT images or biplane CT images were taken to determine the coordinates of the target point, which was the center of the hematoma. Then, a silicon tube (O.D. 3.5 phi, I.D. 2.1 phi) was inserted into the center of the hematoma through a burr-hole under local anesthesia, and the liquid or solid hematoma was aspirated as completely as possible with a syringe. Urokinase (6,000 I.U./5 ml saline) was administered through this silicon tube every 6 or 12 hours for several days until the hematoma had drained out competely. The silicon tube was taken out when repeated CT scanning revealed no hematoma. The results of clinical follow-ups indicated that this procedure is as good as, or rather better than conventional microsurgery with evacuation of hematoma under direct vision. Moreover this CT-guided stereotactic approach for evacuation of the hematoma has the following advantages: 1) the procedure is simple and safe, 2) operation can be performed under local anesthesia, and 3) the hematoma is drained out completely with the aid of urokinase. This surgery seems indicated as an emergency treatment for high-age or high risk patients and also as a routine surgery for intracerebral hematomas in patients showing no herination signs. (author)

  20. CT-guided percutaneous neurolysis methods. State of the art and first results

    International Nuclear Information System (INIS)

    Schneider, B.; Richter, G.M.; Roeren, T.; Kauffmann, G.W.

    1996-01-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [de

  1. CT-guided percutaneous conformal cryoablation for lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yueyong, Xiao; Bin, Wu; Xiao, Zhang; Hongjun, Li; Da, Yu; Jie, Li; Jun, Li [Department of Radiology, PLA General Hospital, Beijing (China)

    2010-02-15

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  2. CT-guided percutaneous conformal cryoablation for lung carcinoma

    International Nuclear Information System (INIS)

    Xiao Yueyong; Wu Bin; Zhang Xiao; Li Hongjun; Yu Da; Li Jie; Li Jun

    2010-01-01

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  3. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  4. CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections

    International Nuclear Information System (INIS)

    Marano, I.; Mainenti, P.P.; Selva, G.; Cannavale, M.; Sodano, A.

    1999-01-01

    The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections [it

  5. [Predictive factors of complications during CT-guided transthoracic biopsy].

    Science.gov (United States)

    Fontaine-Delaruelle, C; Souquet, P-J; Gamondes, D; Pradat, E; de Leusse, A; Ferretti, G R; Couraud, S

    2017-04-01

    CT-guided transthoracic core-needle biopsy (TTNB) is frequently used for the diagnosis of lung nodules. The aim of this study is to describe TTNBs' complications and to investigate predictive factors of complications. All consecutive TTNBs performed in three centers between 2006 and 2012 were included. Binary logistic regression was used for multivariate analysis. Overall, 970 TTNBs were performed in 929 patients. The complication rate was 34% (life-threatening complication in 6%). The most frequent complications were pneumothorax (29% included 4% which required chest-tube) and hemoptysis (5%). The mortality rate was 0.1% (n=1). In multivariate analysis, predictive factor for a complication was small target size (AOR=0.984; 95% CI [0.976-0.992]; P<0.001). This predictive factor was also found for occurrence of life-threatening complication (AOR=0.982; [0.965-0.999]; P=0.037), of pneumothorax (AOR=0.987; [0.978-0.995]; P=0.002) and of hemoptysis (AOR=0.973; [0.951-0.997]; P=0.024). One complication occurred in one-third of TTNBs. The proportion of life-threatening complication was 6%. A small lesion size was predictive of complication occurrence. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. CT-guided stereotactic operation for hypertensive intracerebral hematoma

    International Nuclear Information System (INIS)

    Takahashi, Shinichiro; Sonobe, Makoto; Koshu, Keiji; Kusunose, Mutsuo; Tsumura, Kotaro

    1989-01-01

    CT-guided stereotactic operation was performed in 55 patients with hypertensive intracerebral hematoma. Location of the hematoma was putamen in 28 cases, thalamus in 14 cases, subcortical area in 9 cases, cerebellum in 3 cases and pons in one case. Ages ranged from 36 to 85 years (mean 59.5). The mean timing of the surgery after bleeding was 4.2 days. The estimated volume of the hematoma on CT was 8 ml to 57 ml in putaminal, 9 ml to 40 ml in thalamic, 18 ml to 77 ml in subcortical, 17 ml to 26 ml in cerebellar and 5 ml in pontine hemorrhage. Aspiration rate at surgery was 60.4% in putaminal, 37.9% in thalamic, 41.7% in subcortical, 45.2% in cerebellar and 30% in pontine hemorrhage. In addition, we evaluated ADL at 6 months postoperatively in patients with putaminal and thalamic hamorrhage. It is concluded that stereotactic operation is advisable in those cases with 10 to 50 ml hematoma volumes in putamen or thalamus. On the other hand, in cases with over 50ml volume, hematoma should be evacuated by craniotomy. (author)

  7. CT guided stereotactic evacuation of hypertensive and traumatic intracerebral hematomas

    International Nuclear Information System (INIS)

    Hondo, Hideki; Matsumoto, Keizo

    1983-01-01

    Recent advancement of CT system provides not only definite diagnosis and location of intracerebral hematoma but also coordinates of the center of the hematoma. Trials of stereotactic evacuation of the hematoma have been reported by some authors in the cases of subacute or chronic stages of hypertensive intracerebral hemorrhage. In this series, similar surgery has been performed in 33 cases of hypertensive intracerebral hematoma including 22 cases in acute stage, and 2 cases of traumatic hematoma. Clinical outcomes were investigated and the results were considered to be equivalent or rather better in the conventional microsurgery with evacuation of hematoma under direct vision. However, there still remained controversial problems in the cases of threatened herniation signs, because in these cases regular surgery with total evacuation of the hematoma at one time might have been preferable. The benefits of this CT guided stereotactic approach for the evacuation of the hematoma were thought to be as follow: 1) the procedure is simple and safe, 2) operation is readily performed under local anesthesia, and 3) the hematoma was drained out totally by means of urokinase activity. It is our impression that this surgery not only is indicated as emergency treatment for the patients of high-age or in high risk, but also can institute as a routine surgery for the intracerebral hematomas in patients showing no herniation sign. (J.P.N.)

  8. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  9. Clinical investigation of CT-guided ozone-blowing and fumigation ...

    African Journals Online (AJOL)

    Clinical investigation of CT-guided ozone-blowing and fumigation therapy for the chronic ... African Journal of Biotechnology ... In control group, seven patients were completely cured in 45 days after being treated by traditional surgery.

  10. CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Pitton, Michael Bernhard; Herber, Sascha; Koch, Ulrike; Oberholzer, Katja; Dueber, Christoph [Johannes Gutenberg-University of Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Drees, Philip [University Hospital, Johannes Gutenberg-University of Mainz, Department of Orthopedic Surgery, Mainz (Germany)

    2008-11-15

    The aim of this study was to analyze the technical results, the extraosseous cement leakages, and the complications in our first 500 vertebroplasty procedures. Patients with osteoporotic vertebral compression fractures or osteolytic lesions caused by malignant tumors were treated with CT-guided vertebroplasty. The technical results were documented with CT, and the extraosseous cement leakages and periinterventional clinical complications were analyzed as well as secondary fractures during follow-up. Since 2002, 500 vertebroplasty procedures have been performed on 251 patients (82 male, 169 female, age 71.5 {+-} 9.8 years) suffering from osteoporotic compression fractures (n = 217) and/or malignant tumour infiltration (n = 34). The number of vertebrae treated per patient was 1.96 {+-} 1.29 (range 1-10); the numbers of interventions per patient and interventions per vertebra were 1.33 {+-} 0.75 (range 1-6) and 1.01 {+-} 0.10, respectively. The amount of PMMA cement was 4.5 {+-} 1.9 ml and decreased during the 5-year period of investigation. The procedure-related 30-day mortality was 0.4% (1 of 251 patients) due to pulmonary embolism in this case. The procedure-related morbidity was 2.8% (7/251), including one acute coronary syndrome beginning 12 h after the procedure and one missing patellar reflex in a patients with a cement leak near the neuroformen because of osteolytic destruction of the respective pedicle. Additionally, one patient developed a medullary conus syndrome after a fall during the night after vertebroplasty, two patients reached an inadequate depth of conscious sedation, and two cases had additional fractures (one pedicle fracture, one rib fracture). The overall CT-based cement leak rate was 55.4% and included leakages predominantly into intervertebral disc spaces (25.2%), epidural vein plexus (16.0%), through the posterior wall (2.6%), into the neuroforamen (1.6%), into paravertebral vessels (7.2%), and combinations of these and others. During follow

  11. CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures

    International Nuclear Information System (INIS)

    Pitton, Michael Bernhard; Herber, Sascha; Koch, Ulrike; Oberholzer, Katja; Dueber, Christoph; Drees, Philip

    2008-01-01

    The aim of this study was to analyze the technical results, the extraosseous cement leakages, and the complications in our first 500 vertebroplasty procedures. Patients with osteoporotic vertebral compression fractures or osteolytic lesions caused by malignant tumors were treated with CT-guided vertebroplasty. The technical results were documented with CT, and the extraosseous cement leakages and periinterventional clinical complications were analyzed as well as secondary fractures during follow-up. Since 2002, 500 vertebroplasty procedures have been performed on 251 patients (82 male, 169 female, age 71.5 ± 9.8 years) suffering from osteoporotic compression fractures (n = 217) and/or malignant tumour infiltration (n = 34). The number of vertebrae treated per patient was 1.96 ± 1.29 (range 1-10); the numbers of interventions per patient and interventions per vertebra were 1.33 ± 0.75 (range 1-6) and 1.01 ± 0.10, respectively. The amount of PMMA cement was 4.5 ± 1.9 ml and decreased during the 5-year period of investigation. The procedure-related 30-day mortality was 0.4% (1 of 251 patients) due to pulmonary embolism in this case. The procedure-related morbidity was 2.8% (7/251), including one acute coronary syndrome beginning 12 h after the procedure and one missing patellar reflex in a patients with a cement leak near the neuroformen because of osteolytic destruction of the respective pedicle. Additionally, one patient developed a medullary conus syndrome after a fall during the night after vertebroplasty, two patients reached an inadequate depth of conscious sedation, and two cases had additional fractures (one pedicle fracture, one rib fracture). The overall CT-based cement leak rate was 55.4% and included leakages predominantly into intervertebral disc spaces (25.2%), epidural vein plexus (16.0%), through the posterior wall (2.6%), into the neuroforamen (1.6%), into paravertebral vessels (7.2%), and combinations of these and others. During follow-up (15

  12. CT guided stereotactic evacuation for hypertensive intracerebral hematoma

    International Nuclear Information System (INIS)

    Nakajima, Hideo

    1990-01-01

    Sixty-one cases of hypertensive intracerebral hematoma were evacuated by CT guided stereotactic method. The operation was performed in the CT room under general anesthesia using the KOMAI-NAKAJIMA STEREOTACTIC DEVICE. This instrument has a micromanipulater that can be used for various kinds of stereotactic procedures. Three dimensional position of the target point (aspiration point of the hematoma) was determined on the film obtained from CT scanning of the patient in the stereotactic system. If the hematoma was small, the target point was enough to be one point at the center of the hematoma, but in case of the large hematoma, several target points were given according to the shape of hematoma. The probe, ordinarily a steel tube 4 mm in outer diameter, was inserted through brain to the target point and the hematoma was aspirated through a silicon tube connected to a vacuum system. Among 61 cases examined, 30 cases of thalamic hemorrhage were operated upon and 36 cases were not operated. They were classified according to the volume of hematoma into 3 groups as follows: A=less than 10 ml, B=11-25 ml, C=more than 25 ml. The operated cases were compared with the non operated cases on the improvement of consciousness in each group. In the A group, the operated patients in the level I recovered more slowly than the non operated patients, but in the level II patients, this was reversed. In the B group, the operated patients improved more quickly except the level I patients. In the C group, almost all of non operated patients died. Thus, this operation was very useful in improving consciousness of level II or III patients independent of hematoma volume. It accelerated the recovery of motor function in the level I. This non inversive technique is considered effective for the removal of deep intracerebral hematoma. (author)

  13. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  14. CT-guided diagnostic interventions for classification of focal hepatic lesions: A comparison of 14 G- and 18 G-large bore cutting needles; CT-gesteuerte perkutane Biopsien zur Klassifizierung von fokalen Leberlaesionen: Vergleich zwischen 14 G- und 18 G-Stanzbiopsienadeln

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Piroth, W.; Staatz, G.; Adam, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1999-07-01

    Purpose: Analysis and comparison of CT-guided 14- and 18-gauge cutting needle biopsies to accurately assess focal liver disease. Methods: The data of 272 CT-guided biopsies in 268 patients were evaluated retrospectively with regard to sensitivity, specificity and complication rate of the chosen needle caliber in differentiating between benign and malignant disease as well as in the ability to determine specific cell types in the various disorders. A 14-gauge (G) needle was used in 101 (37.1%) cases, in 18-g needle biopsy was performed in 171 (62.9%) cases. The Fisher exact test was employed for statistical analysis. Results: Cutting needle biopsy yielded sufficient histologic material in 267 of 272 (98.2%) cases. Correct diagnosis of malignancy was established in 178 of 191 (93.2%) lesions, 73 of 76 (96.1%) disorders were accurately defined as benign, resulting in an overall value of 94.0% (251 of 267). Of these 251 biopsies a definite histological diagnosis could be determined in 90.6% of the cases employing a 14 G needle and in 90.3% using an 18-g needle. The sensitivity, specificity and rate of complications were 94.8%, 92.0%%, 3.0% for the 14-g needle and 92.7%, 97.6%, 0.6% for the 18-g needle, respectively. There were no statistically significant differences with regard to the needle size. Conclusions: CT-guided biopsy of hepatic lesions with the 18-g biopsy needle is of equivalent diagnostic accuracy when compared with the 14-g needle. (orig.) [Deutsch] Ziel: Analyse und Vergleich CT-gesteuerter Fein- und Grobstanzbiopsien zur definitiven Abklaerung unklarer fokaler Leberveraenderungen. Methoden: Die Daten von insgesamt 272 CT-gefuehrten Punktionen an 268 Patienten wurden retrospektiv hinsichtlich Sensitivitaet, Spezifitaet und Komplikationsrate zur Dignitaetsbestimmung und Faehigkeit zur artdiagnostischen Einordnung unter Beruecksichtigung der Groesse der gewaehlten Punktionsnadel ueberprueft und ausgewertet. In 101 (37,1%) Faellen wurde eine 14 Gauge (G

  15. Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

    Directory of Open Access Journals (Sweden)

    Artner J

    2012-08-01

    Full Text Available Juraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique.Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections.Study design: Comparative study with technical considerations.Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided.Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels.Conclusion: Radiation dose of CT-guided SI joint injections can be

  16. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  17. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  18. Percutaneous CT-guided cryoablation of the dorsal penile nerve for treatment of symptomatic premature ejaculation.

    Science.gov (United States)

    David Prologo, J; Snyder, Laura L; Cherullo, Edward; Passalacqua, Matthew; Pirasteh, Ali; Corn, David

    2013-02-01

    To evaluate expansion of image-guided interventional cryoablation techniques usually employed for pain management to address the feasibility, safety, and efficacy of treatment for a urologic condition with otherwise limited treatment options, premature ejaculation (PE). Prospective institutional review board approval was obtained, and 24 subjects with PE were enrolled. All patients underwent unilateral percutaneous computed tomography-guided cryoablation of the dorsal penile nerve (DPN). Postprocedural intravaginal ejaculatory latency times (IELTs) and PE Profile (PEP) results served as outcome variables. In addition, subjects were asked whether they would have the procedure done again based on their experience at the 180- and 360-day marks. The technical success rate was 100%. Baseline average IELT was 54.7 seconds ± 7.8 (n = 24), which increased to a maximum of 256 seconds ± 104 (n = 11; P = .241) by day 7 and decreased to 182.5 seconds ± 87.8 (n = 6; P = .0342) by day 90. The mean IELT remained at 182.5 seconds ± 27.6 at day 180 (n = 23; PIELTs significantly improved at 180 and 360 days, and 83% of subjects reported that they would undergo the procedure again if given the same opportunity. There were no procedure-related complications. CT-guided percutaneous unilateral cryoablation of the DPN is a feasible, safe, single-day outpatient procedure for the treatment of symptomatic PE. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  19. CT-guided high-dose-rate brachytherapy of unresectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Collettini, Federico; Schreiber, Nadja; Schnapauff, Dirk; Denecke, Timm; Hamm, Bernd; Gebauer, Bernhard; Wust, Peter; Schott, Eckart

    2015-01-01

    The purpose of the present study was to evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) in patients with unresectable hepatocellular carcinoma (HCC). Over a 6-year period, 98 patients with 212 unresectable HCC underwent CT-HDRBT applying a 192 Ir source at our institution. Magnetic resonance imaging (MRI) follow-up was performed 6 weeks after the intervention and then every 3 months. The primary endpoint was local tumor control (LTC); secondary endpoints included progression-free survival (PFS) and overall survival (OS). Patients were available for MRI evaluation for a mean follow-up of 23.1 months (range 4-64 months; median 20 months). Mean tumor diameter was 5 cm (range 1.8-12 cm). Eighteen of 212 (8.5 %) tumors showed local progression after a mean LTC of 21.1 months. In all, 67 patients (68.4 %) experienced distant tumor progression. The mean PFS was 15.2 months. Forty-six patients died during the follow-up period. Median OS was 29.2 months. Actuarial 1-, 2-, and 3-year OS rates were 80, 62, and 46 %, respectively. CT-HDRBT is an effective therapy to attain local tumor control in patients with unresectable HCC. Prospective randomized studies comparing CT-HDRBT with the standard treatments like Radiofrequency ablation (RFA) and chemoembolization (TACE) are mandatory. (orig.) [de

  20. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  1. CT-Guided Drainage of Pericardial Effusion after Open Cardiac Surgery.

    Science.gov (United States)

    Nour-Eldin, Nour-Eldin Abdelrehim; Alsubhi, Mohammed; Gruber-Rouh, Tatjana; Vogl, Thomas J; Kaltenbach, Benjamin; Soliman, Hazem Hamed; Hassan, Wael Eman; Abolyazid, Sherif Maher; Naguib, Nagy N

    2017-08-01

    This study was designed to evaluate the safety and efficacy of CT-guided drainage of the pericardial effusion in patients after cardiac surgery. The study included 128 consecutive patients (82 males, 46 females; mean age 66.6 years, SD: 4.2) complicated by pericardial effusion or hemopericardium after cardiac surgeries between June 2008 and June 2016. The medical indication for therapeutic pericardiocentesis in all patients was hemodynamic instability caused by pericardial effusion. The treatment criteria for intervention were evidence of pericardial tamponade with ejection fraction (EF) effusion was 260 ml (range 80-900 ml; standard deviation [SD]: ±70). Directly after pericardiocentesis, there was a significant improvement of the ejection fraction to 40-55% (mean: 45%; SD: ±5; p effusion drainage was 10%. The drainage was applied anteriorly (preventricular) in 39 of 128 (30.5%), retroventricularly in 33 of 128 (25.8%), and infracardiac in 56 of 128 (43.8%). Recurrence rate of pericardial effusion after removal of drains was 4.7% (67/128). Complete drainage was achieved in retroventricular and infracardiac positioning of the catheter (p effusion is a minimally invasive technique for the release of the tamponade effect of the effusion and improvement of cardiac output.

  2. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    International Nuclear Information System (INIS)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P.; Sun, H.H.; Jiang, Y.H.

    2011-01-01

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  3. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P. (Dept. of Spinal Surgery, Xian Red Cross Hospital, Xian Shaanxi (China)), email: zqpddn1@gmail.com; Sun, H.H. (Dept. of Orthopaedic, Tangdu Hospital, Fourth Military Medical Univ., Xian Shaanxi (China)); Jiang, Y.H. (Dept. of Radiology, Xian Red Cross Hospital, Xian Shaanxi (China))

    2011-11-15

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  4. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  5. The contribution of CT-guided transthoracic lung biopsy to the diagnosis of organising pneumonia.

    Science.gov (United States)

    Metzger, F; Pernet, D; Manzoni, P; Ranfaing, E; Dalphin, J-C

    2010-09-01

    Organising pneumonia is a pulmonary disease with variable clinical and radiological features and with many differential diagnoses. Diagnosis is based on histology obtained by either transbronchial or surgical lung biopsy but these techniques have several disadvantages. The aim of this study was to evaluate the diagnostic yield of CT-guided transthoracic lung biopsy in organising pneumonia and to compare it to the usual diagnostic tools. Six cases of organising pneumonia diagnosed with CT-guided lung biopsy are reported and discussed. The role of CT-guided lung biopsy in the diagnosis of organising pneumonia was also reviewed in the literature. CT-guided transthoracic lung biopsies provided a higher rate of adequate samples than transbronchial biopsies (92-100% versus 77-86%). The samples were larger, which reduced the risks of misdiagnosis and increased the diagnostic yield (88-97% versus 26-55% in pulmonary nodules and 42-100% versus 66-75% in diffuse pulmonary disease). Complications were rare and generally not serious. CT-guided transthoracic lung biopsy may be considered in place of transbronchial biopsy in the diagnosis of organising pneumonia. Surgical lung biopsy remains the gold standard method for diagnosis. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  6. A study on CT-guided stereotactic technique for functional neurosurgery

    International Nuclear Information System (INIS)

    Uetsuhara, Koichi; Asakura, Tetsuhiko; Hirahara, Kazuho; Gondo, Masazumi; Oda, Hiroshige

    1987-01-01

    Recently, CT-guided stereotactic surgery has become of major interest, and some authors have discussed its potential in functional neurosurgery. The following is a comparative study of the CT-guided stereotactic technique and the conventional roentogenographic stereotactic technique. The Brown-Roberts-Wells apparatus was used for both types of procedures. 37 stereotactic procedures were performed on 35 patients under local anesthesia; 16 for stereotactic biopsy and 21 for stereotactic functional neurosurgery. Target points for stereotactic biopsy were determined by the CT-guided technique and target points for functional neurosurgery were determined by the conventional roentogenographic technique. The correlation with the position of target point determined by both techniques was investigated in the 21 functional neurosurgical procedures. On these occasions the authors used the reformatted horizontal and sagittal CT through the anterior and posterior commissure to determine the position of target point by the CT-guided technique. Results: It was found that the AC-PC line crossed with Reid's base line at angle of 11 ± 1 deg, and therefore it is important to obtain a CT images including AC-PC line at this angle. When applying the CT guided stereotactic procedure for functional surgery, it should be known that there could be a discrepancy within 2 mm from the conventional target determination. (author)

  7. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  8. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  9. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  10. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  11. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  12. CT guided celiac plexus and splanchnic nerve neurolysis : the modified anterior approach

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Ym, Seong Hee; Lee, Jin Hee

    1997-01-01

    Since it was first described by Kappis, celiac plexus neurolysis (CPN) has been performed under fluoroscopic guidance by anesthetists or surgeons for the relief of intractable pain caused by upper abdominal malignancy. Recently, however, several groups have reported a computed tomography (CT)-guided technique that increased the safety of the blocking procedure and improved its results. The authors present a new technique CT-guided celiac plexus and splanchic nerve block, to be used simultaneously with a modified anterior approach. Using CT to guide needle tip placement, an anterior approach that permitted direct neurolysis of the celiac ganglia and splanchnic nerve was developed

  13. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus [Beaumont Hospital, Department of Radiology (Ireland)

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  14. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  15. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  16. Therapeutic impact of CT-guided percutaneous catheter drainage in treatment of deep tissue abscesses

    International Nuclear Information System (INIS)

    Asai, Nobuhiro; Ohkuni, Yoshihiro; Kaneko, Norihiro; Aoshima, Masahiro; Yamazaki, Ikuo; Kawamura, Yasutaka

    2013-01-01

    Combination therapy of CT-guided percutaneous drainage and antibiotics is the first-line treatment for abscesses. Its effectiveness has been demonstrated. However, the therapeutic impact of this procedure for infection treatment has never been reported. We retrospectively analyzed all 47 patients who received CT-guided percutaneous drainage for infection treatment. Patients' characteristics, pathogens isolated, antibiotics administered, technical and clinical outcomes, complications related to this procedure and therapeutic impacts were investigated. Patients were 26 males and 21 females. The mean age was 63.5 years (±18.7). The diseases targeted were 19 retroperitoneal abscesses, 18 intraabdominal abscesses, three pelvic abscesses, and seven others. As for technical outcomes, all of the 54 procedures (100%) were successful. As for clinical outcomes, 44 (93.6%) were cured and three patients (6.4%) died. No complications related to this procedure were found in this study. A total of 42 patients (88%) had a change in the management of their infection as a result of CT-guided percutaneous drainage, such as selection and discontinuation of antibiotics. In conclusion, CT-guided percutaneous drainage is a safe and favorable procedure in the treatment of deep tissue abscesses. Therapeutic impact of these procedures helped physicians make a rational decision for antibiotics selection. (author)

  17. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  18. A case of transitional cell carcinoma associated with pericalyceal diverticulum diagnosed by CT guided percutaneous cystgraphy

    International Nuclear Information System (INIS)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira; Anno, Hirofumi; Hujita, Tamio

    1983-01-01

    Computed tomography (CT) performed on a 42-year-old male patient with a chief complaint of hematuria revealed a renal cyst with a thickened and irregularly shaped wall. CT with contrast medium injected into the cyst by puncture under CT guide detected tumors on the cystic wall preoperatively. (Ueda, J.)

  19. Stress-induced osteolysis of distal clavicle: imaging patterns and treatment using CT-guided injection

    Energy Technology Data Exchange (ETDEWEB)

    Sopov, V.; Groshar, D. [Dept. of Nuclear Medicine, Technion-Israel Inst. of Technology, Haifa (Israel); Fuchs, D. [Dept. of Orthopaedics, Technion-Israel Inst. of Technology, Haifa (Israel); Bar-Meir, E. [Dept. of Radiology, Technion-Israel Inst. of Technology, Haifa (Israel)

    2001-02-01

    Osteolysis of distal clavicle (ODC) may occur in patients who experience repeated stress or microtrauma to the shoulder. This entity has clinical and radiological findings similar to post-traumatic ODC. We describe a case of successful treatment of stress-induced ODC with CT-guided injection of corticosteroid and anesthetic drug into the acromioclavicular joint. (orig.)

  20. Stress-induced osteolysis of distal clavicle: imaging patterns and treatment using CT-guided injection

    International Nuclear Information System (INIS)

    Sopov, V.; Groshar, D.; Fuchs, D.; Bar-Meir, E.

    2001-01-01

    Osteolysis of distal clavicle (ODC) may occur in patients who experience repeated stress or microtrauma to the shoulder. This entity has clinical and radiological findings similar to post-traumatic ODC. We describe a case of successful treatment of stress-induced ODC with CT-guided injection of corticosteroid and anesthetic drug into the acromioclavicular joint. (orig.)

  1. Therapeutic impact of CT-guided percutaneous catheter drainage in treatment of deep tissue abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Nobuhiro; Ohkuni, Yoshihiro; Kaneko, Norihiro; Aoshima, Masahiro; Yamazaki, Ikuo; Kawamura, Yasutaka, E-mail: nobuhiro0204@hotmail.com [Kameda Medical Center, Chiba (Japan)

    2013-03-15

    Combination therapy of CT-guided percutaneous drainage and antibiotics is the first-line treatment for abscesses. Its effectiveness has been demonstrated. However, the therapeutic impact of this procedure for infection treatment has never been reported. We retrospectively analyzed all 47 patients who received CT-guided percutaneous drainage for infection treatment. Patients' characteristics, pathogens isolated, antibiotics administered, technical and clinical outcomes, complications related to this procedure and therapeutic impacts were investigated. Patients were 26 males and 21 females. The mean age was 63.5 years ({+-}18.7). The diseases targeted were 19 retroperitoneal abscesses, 18 intraabdominal abscesses, three pelvic abscesses, and seven others. As for technical outcomes, all of the 54 procedures (100%) were successful. As for clinical outcomes, 44 (93.6%) were cured and three patients (6.4%) died. No complications related to this procedure were found in this study. A total of 42 patients (88%) had a change in the management of their infection as a result of CT-guided percutaneous drainage, such as selection and discontinuation of antibiotics. In conclusion, CT-guided percutaneous drainage is a safe and favorable procedure in the treatment of deep tissue abscesses. Therapeutic impact of these procedures helped physicians make a rational decision for antibiotics selection. (author)

  2. Impact of delineation uncertainties on dose to organs at risk in CT-guided intracavitary brachytherapy.

    LENUS (Irish Health Repository)

    Duane, Frances K

    2014-08-07

    This study quantifies the inter- and intraobserver variations in contouring the organs at risk (OARs) in CT-guided brachytherapy (BT) for the treatment of cervical carcinoma. The dosimetric consequences are reported in accordance with the current Gynecological Groupe Européen de Curiethérapie\\/European Society for Therapeutic Radiology and Oncology guidelines.

  3. Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety

    Directory of Open Access Journals (Sweden)

    Artner Juraj

    2012-08-01

    Full Text Available Abstract Background Image guided spinal injections are successfully used in the management of low back pain and sciatica. The main benefit of CT-guided injections is the safe, fast and precise needle placement, but the radiation exposure remains a serious concern. The purpose of the study was to test a new institutional low-dose protocol for CT-guided periradicular injections in lumbar spine to reduce radiation exposure while increasing accuracy and safety for the patients. Methods We performed a retrospective analysis of a prospective database during a 4-month period (Oct-Dec 2011 at a German University hospital using a newly established low-dose-CT-protocol for periradicular injections in patients suffering from lumbar disc herniation and nerve root entrapment. Inclusion criteria were acute or chronic nerve root irritation due to lumbar disc hernia, age over 18, compliance and informed consent. Excluded were patients suffering from severe obesity (BMI > 30, coagulopathy, allergy to injected substances, infection and non-compliant patients. Outcome parameters consisted of the measured dose length product (mGycm2, the amount of scans, age, gender, BMI and the peri-interventional complications. The results were compared to 50 patients, treated in the standard-interventional CT-protocol for spinal injections, performed in June-Oct 2011, who met the above mentioned inclusion criteria. Results A total amount of 100 patients were enrolled in the study. A significant radiation dose reduction (average 85.31% was achieved using the institutional low-dose protocol compared to standard intervention mode in CT-guided periradicular injections in lumbar spine. Using the low-dose protocol did not increase the complications rate in the analyzed cohort. Conclusions Low-dose-CT-protocols for lumbar perineural injections significantly reduce the exposure to radiation of non-obese patients without an increase of complications. This increases long-time patient

  4. The cost-effectiveness of CT-guided sacroiliac joint injections: a measure of QALY gained.

    Science.gov (United States)

    Bydon, Mohamad; Macki, Mohamed; De la Garza-Ramos, Rafael; Youssef, Mina; Gokaslan, Ziya L; Meleka, Sherif; Bydon, Ali

    2014-10-01

    The purpose of this study is to estimate the total cost and the quality of life years (QALY) gained for computer tomography (CT)-guided sacroiliac joint (SIJ) injections. The cost per QALY gained for the procedure is the primary end-point of this study. In our 1-year prospective institutional study, we gathered 30 patients undergoing CT-guided SIJ injections for degenerative changes at the SIJ space. Patient-reported outcomes included both the US population-based EQ-5D (EuroQol) index score and the EQ-visual analog scale (VAS). The EQ-5D is based on mobility, self-care, usual activities, pain/discomfort, and anxiety depression. Utility expenditures were based on hospital charges at our institution. All 30 patients had one pre-injection physician visit followed by 43 initial injections (13 bilateral). Each patient underwent one CT scan, and three patients required additional plain films. In the 1 year following the injections, 26 physician visits were documented. Five patients required repeat CT-guided injections. Total 1-year cost for all 30 patients was $34 874·00. Mean decrease in EQ-VAS was 0·60 (P  =  0·187). The mean 1-year gain of 0·58 EQ-5D QALY reached statistical significance (P sacroiliac injections was $2004·29. In one of the first cost analyses of CT-guided sacroiliac injections, we found that the procedure improves pain and activities of daily living. The cost per QALY gained by CT-guided sacroiliac injections falls well below the threshold cost of 1 QALY, suggesting that the procedure is strongly cost-effective.

  5. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  6. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  7. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  8. Clinical experience of quantex coordinate software for CT guided stereotactic surgery

    International Nuclear Information System (INIS)

    Yabashi, Toshitake; Ichikawa, Hideo; Yasuda, Eisuke; Tsuruta, Hatsuo; Ishikawa, Yoshihisa; Kimura, Tokuji; Kanamori, Isao

    1991-01-01

    Recently, Quantex Coordinate Software was newly developed for CT-guided stereotactic surgery. We have the opportunity of using this software in 6 cases with intracerebral hematoma for evacuation and 2 cases with brain tumor for needle biopsy by using CT-guided stereotactic surgery. The followings are the features with a little clinical experience. One of the biggest features is that this software can simulate the best expected route of the puncture needle from burr hole to target point before inserting. Also compared with CT 9000 series Software, it has many new functions for more advanced hardware as well as advance standard software. Two cases of intracerebral hematoma for evacuation and 1 case of a brain tumor for a biopsy were carried out using this software mainly as a simulation. In all cases, this software proved to be very useful. (author)

  9. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  10. Complications of CT guided lumbar sympathicolysis: own experience and review of literature

    International Nuclear Information System (INIS)

    Ernst, S.; Heindel, W.; Fischbach, R.; Langen, H.J.; Krahe, T.; Gawenda, M.; Neubauer, S.

    1998-01-01

    Aim: To review the complications of CT guided lumbar sympathicolysis (CTLS) on the basis of our own experience and the available literature. Methods: 241 CTLS were performed by a standard technique according to Haaga's method. Clinical follow-up revealed 4 serious complications; these were analysed and compared with published cases. Results: Amongst our patients there were three fibrotic ureter stenoses and one retroperitoneal abscess. Analysis of the serious complications described in the literature indicates that introduction of CT guided lumbar sympathicolysis has reduced the severity and frequency of complications as compared with surgical and 'blind' procedures. With CTLS, no deaths due to the procedure have been reported in the literature. The results indicate that damage to the ureters can be caused by substances used for the neurolysis. (orig./MG) [de

  11. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  12. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  13. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  14. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  15. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  16. Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma

    Energy Technology Data Exchange (ETDEWEB)

    Lassalle, Louis; Campagna, R.; Corcos, G.; Feydy, A. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service de Radiologie Osteo-Articulaire, Paris (France); Babinet, A. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service de Chirurgie Orthopedique, Paris (France); Larousserie, F. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service d' Anatomo-Pathologie, Paris (France); Stephanazzi, J. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service d' Anesthesie, Paris (France)

    2017-07-15

    To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up. (orig.)

  17. Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma

    International Nuclear Information System (INIS)

    Lassalle, Louis; Campagna, R.; Corcos, G.; Feydy, A.; Babinet, A.; Larousserie, F.; Stephanazzi, J.

    2017-01-01

    To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up. (orig.)

  18. Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma.

    Science.gov (United States)

    Lassalle, Louis; Campagna, R; Corcos, G; Babinet, A; Larousserie, F; Stephanazzi, J; Feydy, A

    2017-07-01

    To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up.

  19. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  20. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  1. CT-guided percutaneous radiofrequency ablation of hepatic malignancies located in unusual regions under general anesthesia

    International Nuclear Information System (INIS)

    Pan Jie; Chen Shaohui; Lu Xin; Mao Yilei; Sang Xinting; Chen Fang; Li Yumei; Huang Yuguang; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility of CT-guided percutaneous radiofrequency ablation (RFA) of liver malignancies located in unusual regions under general anesthesia, and to assess its clinical value. Methods: Eighteen patients with a total of 26 malignant hepatic lesions were enrolled in this study. The lesions were located at diaphragmatic surface, hepatic hilum, hepatic subcapsular site,side of inferior vena cava, side of gallbladder or near by colon. Transcatheter arterial chemoembolization was performed in all patients, which was followed by CT-guided percutaneous RFA under general anesthesia. The time used for puncturing and the time used for putting the needles to the scheduled sites were recorded. A follow-up for 115 months was conducted. The complications and the therapeutic results were observed. Results: For all patients,the procedure of puncture and needle placement was completed in 1-3 minutes. A total of 35 RFA procedures were conducted for 26 lesions. No severe complications occurred. Complete necrosis was observed in 20 tumors and partial necrosis in 6 tumors. Conclusion: The result of this study indicates that CT-guided percutaneous RFA under general anesthesia is a feasible technique for the treatment of liver malignancies located at unusual regions. This technique is very helpful for reducing the manipulating difficulty and lowing the complication risk of RFA procedures. (authors)

  2. Percutaneous CT-guided cryoablation for the treatment of refractory pudendal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Prologo, J.D.; Williams, Roger [Emory University Hospital, Department of Radiology and Imaging Sciences Division of Interventional Radiology and Image-Guided Medicine, Atlanta, GA (United States); Lin, Roger C. [University Hospitals Case Medical Center, Department of Radiology, Cleveland, OH (United States); Corn, David [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States)

    2015-05-01

    To evaluate the safety and efficacy of percutaneous CT-guided cryoablation of the pudendal nerve for the treatment of refractory pudendal neuralgia. Eleven patients were selected to undergo percutaneous CT-guided cryoablation of the pudendal nerve based on established diagnostic criteria. Brief Pain Inventory questionnaires were administered prior to the procedure, during the immediate 24 h post procedure, and 45 days and 6 months following the procedure. Prior to treatment, the average level of pain on a scale from 0 (no pain) to 10 (worst pain imaginable) was 7.6, with pain described as ''burning'' (80%), ''pulling'' (37.5%), ''crushing'' (50%), ''pressure'' (84.5%), ''throbbing'' (50%), ''knife-life'' (52%), and ''other'' (60%). At 24 h, 45 days, and 6 months post-treatment, pain intensity dropped to 2.6, 3.5, and 3.1, respectively (p < 0.005). There were no procedure-related complications. CT-guided percutaneous cryoablation may represent a safe and efficacious option for selected patients with refractory pudendal neuralgia. (orig.)

  3. Use of Low-Fidelity Simulation Laboratory Training for Teaching Radiology Residents CT-Guided Procedures.

    Science.gov (United States)

    Picard, Melissa; Nelson, Rachel; Roebel, John; Collins, Heather; Anderson, M Bret

    2016-11-01

    To determine the benefit of the addition of low-fidelity simulation-based training to the standard didactic-based training in teaching radiology residents common CT-guided procedures. This was a prospective study involving 24 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by low-fidelity simulation-based training on three common CT-guided procedures: random liver biopsy, lung nodule biopsy, and drain placement. Baseline knowledge, confidence, and performance assessments were obtained after the didactic session and before the simulation training session. Approximately 2 months later, all residents participated in a simulation-based training session covering all three of these procedures. Knowledge, confidence, and performance data were obtained afterward. These assessments covered topics related to preprocedure workup, intraprocedure steps, and postprocedure management. Knowledge data were collected based on a 15-question assessment. Confidence data were obtained based on a 5-point Likert-like scale. Performance data were obtained based on successful completion of predefined critical steps. There was significant improvement in knowledge (P = .005), confidence (P simulation-based training to the standard didactic curriculum for all procedures. This study suggests that the addition of low-fidelity simulation-based training to a standard didactic-based curriculum is beneficial in improving resident knowledge, confidence, and tested performance of common CT-guided procedures. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  5. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  6. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  7. CT-guided biopsy: diagnostic relevance, therapeutic consequences and economic aspects

    International Nuclear Information System (INIS)

    Schwarzenberg, H.; Mueller-Huelsbeck, S.; Link, J.; Brossmann, J.; Fahl, M.; Quirin, A.; Heller, M.

    1996-01-01

    Purpose: To evaluate the diagnostic and clinical relevance and therapeutic consequences of CT-guided biopsy with regard to economic aspects. Methods: 213 CT-guided biopsies in 190 were evaluated. All information regarding patient referral, reason for request, body region, underlying diagnosis, and clinical consequences were registered over a period of 22.2±9.4 month. Results: Patient referral to biopsy was mainly from the departments of surgery, internal medicine, and radiotherapy with the question of tumor and metastasis. Less than 5% of biopsies were performed in outpatients. Main regions were the lung (39%), the abdomen (35%), and the skeleton (11%). Biopsy and surgical histology corresponded in 73%. Largest diagnosis groups were benign unspecific tissues or other benign lesions in 24%. As a result of CTP no further procedures necessary in 22.5%. Follow-up studies or conservative treatment were indicated in 11.3%. Surgical procedures were needed in only 15.5%. There was only one complication requiring therapy. Conclusion: CT-guided biopsy is a safe procedure, which helps to avoid unnecessary cost-intensive diagnostics and surgical treatment. If CTP is performed early and in outpatients residence time in the hospital is reduced and thus money is saved. (orig.) [de

  8. CT-guided corticosteroid injection for solitary eosinophilic granuloma of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Rimondi, Eugenio; Rossi, Giuseppe [Istituto Ortopedico Rizzoli, University of Bologna, Department of Radiology and Interventional Angiographic Radiology, Bologna (Italy); Mavrogenis, Andreas F. [Istituto Ortopedico Rizzoli, University of Bologna, Department of Orthopedics, Bologna (Italy); Istituto Ortopedico Rizzoli, University of Bologna, Department of Orthopaedics, Orthopaedic Oncology Service, Bologna (Italy); Ussia, Giuseppe; Angelini, Andrea [Istituto Ortopedico Rizzoli, University of Bologna, Department of Orthopedics, Bologna (Italy); Ruggieri, Pietro [Istituto Ortopedico Rizzoli, University of Bologna, Department of Orthopedics, Bologna (Italy); Istituto Ortopedico Rizzoli, University of Bologna, Department of Orthopaedics, Bologna (Italy)

    2011-06-15

    To evaluate the clinical and imaging outcome of patients with symptomatic eosinophilic granuloma of the spine treated with CT-guided intralesional methylprednisolone injection after biopsy. Patients (n =19) with symptomatic solitary eosinophilic granuloma of the spine treated by CT-guided intralesional methylprednisolone injection were retrospectively studied. There were 12 males and seven females with a mean age of 17 years (range, 3-43 years). The mean follow-up was 6 years (median, 4 years; range, 0.5-19 years). Spinal location included the cervical (two patients), thoracic (seven patients), lumbar spine (eight patients), and the sacrum (two patients). Vertebra plana was observed in two patients. All patients had biopsies before treatment. Complete resolution of pain and healing of the lesion was observed in 17 patients (89.5%); none of these patients had recurrence at the latest examination. Reconstitution of the T1 and L1 vertebra plana was observed in both patients. Two patients initially diagnosed and treated for a solitary eosinophilic granuloma had constant pain after the procedure; in these patients, 6 and 12 months after the procedure, respectively, imaging showed multifocal disease and systemic therapy was administered. Complications related to the procedure were not observed. General anesthesia was administered in two patients because of intolerable pain during the procedure. In view of the benign clinical course of eosinophilic granuloma, in patients with symptomatic lesions, CT-guided intralesional corticosteroid injection is a safe and effective outpatient treatment with a low complication rate. (orig.)

  9. CT-guided periradicular therapy in cervical and lumbar radicular syndromes

    International Nuclear Information System (INIS)

    Nian Dingfang; Zhou Jun; Li Wenhua; Cao Qingxuan; Xia Baosu; Apitzsch, D.E.

    2007-01-01

    Objective: To evaluate the effectiveness of CT-guided periradicular therapy (PRT) in cervical and lumber radicular syndromes. Methods: Seventy two cases of cervical and lumbar radicular syndromes were treated by CT-guided PRT. During PRT, 10-20 mg of Triamhexal and 3-4 ml of Carbostesin 0.25%(Bupivacainhydrochlorid) were injected into the space around the corresponding spinal root, once a week, all together six times as a course. Results: Four hundreds and forty six PRT procedures were carried out in 72 patients having a successful puncture and a satisfying spread of Triamhexal and Carbostesin around the spinal nerve root space for every time. After 6 to 24 months follow up, 62 patients showed a significant pain reduction or complete disappearance. Moderate improvement was not noted in 6 and no improvement in 4. The effective rate was 94.4% without any correlative complication. Conclusions: CT-guided PRT is an effective, easy and safe procedure to treat patients with refractory cervical or lumbar radicular pain syndromes. (authors)

  10. CT-guided cervical interlaminar epidural steroid injection for cervical radiculopathy

    International Nuclear Information System (INIS)

    Chen Wei; Wu Chungen; Wu Chaoxian; Cheng Yongde

    2009-01-01

    Objective: To evaluate the safety and effectiveness of CT-guided cervical interlaminar epidural steroid injection for the treatment of cervical radiculopathy. Methods: CT-guided cervical interlaminar epidural steroid injection was performed in 32 patients with cervical radioculopathy, encountered during the period of Dec. 2006 to June 2008, as the patients failed to respond to the conservative treatment in 2 weeks. The clinical data and the imaging findings were retrospectively analyzed. Before and after the procedure, visual analogue scale (VAS) and Odom criteria were used to evaluate the pain of the patient. Results: Three months after the injection, improvement judged by Odom criteria was seen in 28 patients (87.5%), and the mean pain relief value of VAS was 5.88 ± 1.10. No significant difference in effective rate and in VAS score (P>0.05) was found between protrusion group and degenerative group, between the group with the course over 6 months and the group with the course below 6 months, also between the group receiving one injection and the group receiving the second injection. Conclusion: CT-guided fine needle (23 gauge) puncture epidural steroid (Decadron) 'target spot' injection is an ideal alternative for the treatment of cervical radiculopathy, especially for the patients who fails to respond to the conservative treatment. (authors)

  11. Activity-based cost analysis of hepatic tumor ablation using CT-guided high-dose rate brachytherapy or CT-guided radiofrequency ablation in hepatocellular carcinoma.

    Science.gov (United States)

    Schnapauff, D; Collettini, F; Steffen, I; Wieners, G; Hamm, B; Gebauer, B; Maurer, M H

    2016-02-25

    To analyse and compare the costs of hepatic tumor ablation with computed tomography (CT)-guided high-dose rate brachytherapy (CT-HDRBT) and CT-guided radiofrequency ablation (CT-RFA) as two alternative minimally invasive treatment options of hepatocellular carcinoma (HCC). An activity based process model was created determining working steps and required staff of CT-RFA and CT-HDRBT. Prorated costs of equipment use (purchase, depreciation, and maintenance), costs of staff, and expenditure for disposables were identified in a sample of 20 patients (10 treated by CT-RFA and 10 by CT-HDRBT) and compared. A sensitivity and break even analysis was performed to analyse the dependence of costs on the number of patients treated annually with both methods. Costs of CT-RFA were nearly stable with mean overall costs of approximately 1909 €, 1847 €, 1816 € and 1801 € per patient when treating 25, 50, 100 or 200 patients annually, as the main factor influencing the costs of this procedure was the single-use RFA probe. Mean costs of CT-HDRBT decreased significantly per patient ablation with a rising number of patients treated annually, with prorated costs of 3442 €, 1962 €, 1222 € and 852 € when treating 25, 50, 100 or 200 patients, due to low costs of single-use disposables compared to high annual fix-costs which proportionally decreased per patient with a higher number of patients treated annually. A break-even between both methods was reached when treating at least 55 patients annually. Although CT-HDRBT is a more complex procedure with more staff involved, it can be performed at lower costs per patient from the perspective of the medical provider when treating more than 55 patients compared to CT-RFA, mainly due to lower costs for disposables and a decreasing percentage of fixed costs with an increasing number of treatments.

  12. Ruptured eardrum

    Science.gov (United States)

    ... eardrum ruptures. After the rupture, you may have: Drainage from the ear (drainage may be clear, pus, or bloody) Ear noise/ ... doctor to see the eardrum. Audiology testing can measure how much hearing has been lost. Treatment You ...

  13. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  14. Prospective pilot study of CT-guided microwave ablation in the treatment of osteoid osteomas

    International Nuclear Information System (INIS)

    Prud'homme, Clara; Nueffer, Jean-Philippe; Runge, Michel; Dubut, Jonathan; Kastler, Bruno; Aubry, Sebastien

    2017-01-01

    The aims of this work were to assess the feasibility and efficacy of CT-guided microwave ablation (MWA) in the treatment of osteoid osteomas (OOs). Thirteen consecutive patients (range 11-31 years old) presenting with OO were prospectively included and treated by CT-guided MWA. Power and duration of MWA were both recorded. The patient's pain was assessed using a numeric pain rating scale (NRS), and side effects were recorded during procedures, after 1 day, 7 days and 1 month. The nidus vascularization and the volume of necrosis induced by MWA were assessed using contrast-enhanced MRI. Success was defined as the complete relief of the patient's pain 1 month after the first procedure, associated with necrosis of the nidus on follow-up MRI. The success rate was up to 92.3% (12/13). At 1 day, 7 days and 1 month, the median NRSs were respectively 5 [interquartile range (IQR) 2-5], 0 (IQR 0-1) and 0 (IQR 0-0). Side effects observed were one partial and self-resolving lesion of a sensory branch of the radial nerve and two skin burns. The median power of the MWA used was 60 W (IQR 50-60) with a 1.5-min duration (IQR 1-2), leading to MWA-induced necrosis measuring on average 23 x 15 x 16 mm. CT-guided MWA of OO has a success rate that appears to be almost similar to that of laser or radiofrequency ablation, but care must be taken to prevent nerve or skin lesions. (orig.)

  15. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  16. Prospective pilot study of CT-guided microwave ablation in the treatment of osteoid osteomas

    Energy Technology Data Exchange (ETDEWEB)

    Prud' homme, Clara; Nueffer, Jean-Philippe; Runge, Michel; Dubut, Jonathan [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Kastler, Bruno [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); I4S Laboratory, INSERM EA4268, University of Franche-Comte, Besancon (France); Aubry, Sebastien [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Nanomedecine Laboratory, INSERM EA4662, University of Franche-Comte, Besancon (France)

    2017-03-15

    The aims of this work were to assess the feasibility and efficacy of CT-guided microwave ablation (MWA) in the treatment of osteoid osteomas (OOs). Thirteen consecutive patients (range 11-31 years old) presenting with OO were prospectively included and treated by CT-guided MWA. Power and duration of MWA were both recorded. The patient's pain was assessed using a numeric pain rating scale (NRS), and side effects were recorded during procedures, after 1 day, 7 days and 1 month. The nidus vascularization and the volume of necrosis induced by MWA were assessed using contrast-enhanced MRI. Success was defined as the complete relief of the patient's pain 1 month after the first procedure, associated with necrosis of the nidus on follow-up MRI. The success rate was up to 92.3% (12/13). At 1 day, 7 days and 1 month, the median NRSs were respectively 5 [interquartile range (IQR) 2-5], 0 (IQR 0-1) and 0 (IQR 0-0). Side effects observed were one partial and self-resolving lesion of a sensory branch of the radial nerve and two skin burns. The median power of the MWA used was 60 W (IQR 50-60) with a 1.5-min duration (IQR 1-2), leading to MWA-induced necrosis measuring on average 23 x 15 x 16 mm. CT-guided MWA of OO has a success rate that appears to be almost similar to that of laser or radiofrequency ablation, but care must be taken to prevent nerve or skin lesions. (orig.)

  17. Simple localization of peripheral pulmonary nodules - CT-guided percutaneous hook-wire localization

    International Nuclear Information System (INIS)

    Poretti, F.P.; Vorwerk, D.; Brunner, E.

    2002-01-01

    Background: Video-assisted thoracoscopic surgery (VATS) is an alternative approach to small intrapulmonary nodules, if transbronchial or percutaneous biopsy have failed. We investigated the feasibility and effectiveness of the percutaneous CT-guided placement of hook-wires to localize such nodules before video-assisted thoracoscopy. Subjects and Methods: 19 patients with new by diagnosed intrapulmonary nodules underwent CT-guided hook-wire localization by application of a X-Reidy-Set (Cook, Inc., Bjaeverskov, Denmark). The average age of the patient was 63 years (range: 19-80 years), the mean distance between the nodule and the pleura visceral was 7.58 mm (range: 0-25 mm) and the mean diameter was 11.58 mm (range: 5-25 mm). After localization, the patients underwent a VATS resection of the lesion within a mean time of 30 min (range 10-48 min). Results: In all cases, resection of the nodules was successful. In 4 older patients the marking was complicated by poor cooperability. At the end of manipulation the end of the hook was distanced from the nodule. But also in these cases, resection was successfully performed. 8 patients developed an asymptomatic pneumothorax: 5 of them in a minor (max. 1.5 cm rim), three of them in a moderate (max. 3 cm rim) dimension. In 4 patients, in whom the tumor was hit directly by the needle, local bleeding occurred. In one case, haemoptoe was present. In no patient did a dislocation of the hookwire-system occur. Conclusion: CT-guided placement of a hook-wire system is a simple and reasonable procedure which facilitates safe VATS resection of small pulmonary nodules. (orig.) [de

  18. The factor analysis of the incidence of pneumothorax after CT-guided transthoracic needle aspiration biopsy

    International Nuclear Information System (INIS)

    Zhong Tao; Yu Hongguang; Wang Yong; Yang Sifu; Wang Xiaoxuan

    2007-01-01

    Objective: To analyze the impact of multiple factors on the incidence of pneumothorax associated with CT-guided transthoracic needle aspiration biopsy. Methods: The sign of pneumothorax after 162 cases (lesion diameter from 1 cm to 6 cm) CT-guided transthoracic needle aspiration biopsy was observed and its relationship with multivariate factors were analyzed by multivariate logistic regression model. Results: Thirty-two cases presented pneumothorax accounting for 19. 8%. Single variate analysis showed that the sign of pneumothorax related to intercurrent COPD, distance from lesion and chest wall, needle dwelling time and lesion diameter. 67 patients of intercurrent COPD with postoperative pneumothorax occurred in 22 cases (32.8%); With respect to those having lesions close to the chest wall (48 cases), and the cases with the distance between the chest wall and lesions less than 2 cm (55 cases) and greater than 2 cm (59 cases), the postoperative pneumothorax occurred in 0, 14 (25.5%), 18 (30.5%) cases respectively; For those patients with needle in the chest residence time of less than 10 minutes (82 cases), 10-20 minutes (51 cases), more than 20 minutes (28 cases) after the occurrence of pneumothorax were 8 (9.6%), 10(19.6%), 14 (50%) cases respectively; In contrast, those with lesion diameter less than 2 cm (65 cases), 2-4 cm(52 cases), more than 4cm(45 cases) were 19 (29.2%), 8 (15.4%) and 5 (11.1% ) respectively. The multivariate logistic regression analysis showed that the prior three factor's were risk factors of pneumothorax (OR=4.652, 4.030, 2.855 respectively). Conclusions: To avoid the pneumothorax, caution must be taken with respect to CT-guided transthoracic needle aspiration biopsy, patients with intercurrent COPD, long distance between lesion and chest wall, and smaller lesion diameter. For operation the needle dwell time within thorax should be minimized. (authors)

  19. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  20. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  1. CT-Guided, Ethanol Sympatholysis for Primary Axillary–Palmar Hyperhidrosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsitskari, Maria, E-mail: mariadote@hotmail.com [American Medical Center, Vascular & Interventional Radiology (Cyprus); Friehs, Gerhard, E-mail: gerhardf@amc.com.cy; Zerris, Vassilis, E-mail: vassilisz@amc.com.cy [American Medical Center, Neurosurgery (Cyprus); Georgiades, Christos, E-mail: g-christos@hotmail.com [Johns Hopkins Hospital, Vascular & Interventional Radiology (United States)

    2016-12-15

    PurposePrimary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis.Materials and MethodsNine consecutive patients with axillary–palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinical visits; mean follow-up was 12 months (6–26 months). Descriptive statistics was used to report the outcomes.ResultsOne procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner’s or compensatory hyperhidrosis were observed.ConclusionsCT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.

  2. Clinical application of CT-guided radiofrequency ablation for the treatment of metastatic bone neoplasms

    International Nuclear Information System (INIS)

    Gong Ju; Lu Zhijun; Wang Zhongmin; Zhang Liyun; Zheng Yunfeng; Chen Kemin

    2009-01-01

    Objective: To investigate the clinical efficacy of CT-guided radiofrequency ablation (RFA) for the treatment of metastatic bone neoplasms. Methods: Under intravenous aneaesthesia, CT- guided RFA was performed in 20 patients with metastatic bone tumor. The degree of pain was evaluated at 24 hours, 3 and 6 months after the operation by brief pain inventory (BPI). Results: All patients were followed up for 6 months and survived so far. The average peak pain score before the operation was 8.1 (6-10), which decreased significantly to 6.1, 4.6, 3.3 and 3.0 at 24 hours, 1, 3 and 6 months after the operation respectively (P<0.001). The mean pain score before the operation was 6.3, which decreased significantly to 4.0, 2.3, 2.13 and 1.9 at 24 hours, 1, 3 and 6 months after the operation respectively (P<0.001). After RFA treatment, the KPS scores of all patients increased while the CT values of the bone lesions decreased. No major complications occurred both during and after the operation. One patient with vertebral lamina destruction suffered from lower limb hypoesthesia after RFA procedure, and the lower limb sensation was restored within 48 hours after the injection of prednisone was employed. Conclusion: CT-guided radiofisequency ablation is a safe, effective, minimally-invasive and up-to-date technique for the treatment of metastatic bone neoplasms with excellent anti-pain effect, its short-term response is sure and reliable. (authors)

  3. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    International Nuclear Information System (INIS)

    Datir, A.; Connell, D.

    2010-01-01

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT-guided

  4. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    Energy Technology Data Exchange (ETDEWEB)

    Datir, A., E-mail: apdatir@gmail.co [Jackson Memorial Hospital, Miami, FL (United States); Connell, D. [Royal National Orthopaedic Hospital NHS Trust, Stanmore, Middlesex (United Kingdom)

    2010-01-15

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT-guided

  5. Development of the robot system to assist CT-guided brain surgery

    International Nuclear Information System (INIS)

    Koyama, H.; Funakubo, H.; Komeda, T.; Uchida, T.; Takakura, K.

    1999-01-01

    The robot technology was introduced into the stereotactic neurosurgery for application to biopsy, blind surgery, and functional neurosurgery. The authors have developed a newly designed the robot system to assist CT-guided brain surgery, designed to allow a biopsy needle to reach the targget such as a cerebral tumor within a brain automatically on the basis of the X,Y, and Z coordinates obtained by CT scanner. In this paper we describe construction of the robot, the control of the robot by CT image, robot simulation, and investigated a phantom experiment using CT image. (author)

  6. Treatment of osteoid osteoma using CT-guided radiofrequency ablation versus MR-guided laser ablation: A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Gebauer, B.; Wieners, G.; De Bucourt, M.; Renz, D.M.; Hamm, B.; Streitparth, F.

    2012-01-01

    Objective: To compare the costs of CT-guided radiofrequency ablation (RFA) and MR-guided laser ablation (LA) for minimally invasive percutaneous treatment of osteoid osteoma. Materials and methods: Between November 2005 and October 2011, 20 patients (14 males, 6 females, mean age 20.3 ± 9.1 years) underwent CT-guided RFA and 24 patients (18 males, 6 females; mean age, 23.8 ± 13.8 years) MR-guided LA (open 1.0 Tesla, Panorama HFO, Philips, Best, Netherlands) for osteoid osteoma diagnosed on the basis of clinical presentation and imaging findings. Prorated costs of equipment use (purchase, depreciation, and maintenance), staff costs, and expenditure for disposables were identified for CT-guided RFA and MR-guided LA procedures. Results: The average total costs per patient were EUR 1762 for CT-guided RFA and EUR 1417 for MR-guided LA. These were (RFA/LA) EUR 92/260 for equipment use, EUR 149/208 for staff, and EUR 870/300 for disposables. Conclusion: MR-guided LA is less expensive than CT-guided RFA for minimally invasive percutaneous ablation of osteoid osteoma. The higher costs of RFA are primarily due to the higher price of the disposable RFA probes.

  7. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  8. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  9. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  10. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-01-01

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  11. CT-guided percutaneous laser disk decompression for cervical and lumbar disk hernia

    International Nuclear Information System (INIS)

    Shimizu, Kanichiro; Koyama, Tutomu; Harada, Junta; Abe, Toshiaki

    2008-01-01

    Percutaneous laser disk decompression under X-ray fluoroscopy was first reported in 1987 for minimally invasive therapy of lumbar disk hernia. In patients with disk hernia, laser vaporizes a small portion of the intervertebral disk thereby reducing the volume and pressure of the affected disk. We present the efficacy and safety of this procedure, and analysis of fair or poor response cases. In our study, 226 cases of lumbar disk hernia and 7 cases of cervical disk hernia were treated under CT guided PLDD. Japan Orthopedic Association (JOA) score and Mac-Nab criteria were investigated to evaluate the response to treatment. Improvement ratio based on the JOA score was calculated as follows. Overall success rate was 91.6% in cases lumber disk hernia, and 100% in cases of cervical disk hernia. We experienced two cases with two cases with postoperative complication. Both cases were treated conservatively. The majority of acute cases and post operative cases were reported to be 'good' on Mac-Nab criteria. Cases of fair or poor response on Mac-Nab criteria were lateral type, foraminal stenosis or large disk hernia. CT-guided PLDD is a safe and accurate procedure. The overall success rate can be increased by carefully selecting patients. (author)

  12. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  13. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  14. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  16. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com [Matsuyama Shimin Hospital, Department of Radiology (Japan); Watanabe, Ryouhei; Koyano, Yasuhiro [Matsuyama Shimin Hospital, Department of Surgery (Japan); Sugata, Shigenori; Takeda, Yukie [Ehime Prefectural Imabari Hospital, Department of Radiology (Japan); Nakamura, Seiji; Akamune, Akihisa [Matsuyama Shimin Hospital, Department of Radiology (Japan); Tsuda, Takaharu; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology (Japan)

    2017-04-15

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  17. A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves; Bitencourt, Almir G. V.; Barbosa, Paula N. V.; Almeida, Maria Fernanda A.; Zurstrassen, Charles E. [AC Camargo Cancer Center, Department of Imaging (Brazil); Coimbra, Felipe J. F.; Costa, Wilson L. da [AC Camargo Cancer Center, Department of Abdominal Surgery (Brazil); Chojniak, Rubens [AC Camargo Cancer Center, Department of Imaging (Brazil)

    2017-05-15

    PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. After placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.

  18. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  19. Trans-sphenoidal treatment of postsurgical cerebrospinal fluid fistula: CT-guided closure

    International Nuclear Information System (INIS)

    Floris, R.; Salvatore, C.; Simonetti, G.

    1998-01-01

    Cerebrospinal fluid (CSF) leakage after trans-sphenoidal surgery is a troublesome complication with a risk of meningitis and pneumocephalus. We suggest CT-guided intrasphenoidal injection of fibrin sealant through a 12-gauge needle as a simple alternative to surgical management of CSF fistulae. We treated eight patients, operated via the trans-sphenoidal route (five pituitary adenomas, three craniopharyngiomas), for a postoperative CSF leak by CT-guided intrasphenoidal injection of fibrin sealant alone in three cases and fibrin sealant and autologous blood in 5. CT was obtained 10 days after the procedure in all cases. In four patients, the CSF leak was closed successfully at the first attempt. The procedure was repeated on the four remaining patients because only a reduction in leakage was obtained at the first attempt. This procedure preserves olfaction and avoids the risk of frontal lobe damage. It could therefore represent the treatment of choice in many cases of anterior cranial fossa postsurgical CSF leaks. (orig.) (orig.)

  20. Evaluation of the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica

    International Nuclear Information System (INIS)

    Tong Guohai; Wang Wei; Chen Wei; Chen Kemin

    2005-01-01

    Objective: To evaluate the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica. Methods: CT-guided epidural steroid injection was performed in 180 patients with sciatica from May 1998 to March 2004, and all patients had failure to previous conservative treatment. Visual analogue scale was used to evaluate the pain of the patient before and after the treatment. Results: Follow-up was taken for 112 cases during 1-6 years after the treatment, 89 patients (79.5%) had successful long-term outcome and 80 patients (71.4%) were satisfied. Conclusions: CT-guided epidural steroid injection can reduce low back pain and radical pain. It should be preferentially considered as the first choice when conservative treatments are failed. (authors)

  1. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com; Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp; Suzuki, Michiko, E-mail: mamimichiko@me.com [Iwate Medical University School of Medicine, Department of Radiology (Japan); Sone, Miyuki, E-mail: msone@me.com [National Cancer Center Hospital, Department of Diagnostic Radiology (Japan); Tanaka, Ryoichi, E-mail: rtanaka@iwate-med.ac.jp; Nakasato, Tatsuhiko, E-mail: nakasato@iwate-med.ac.jp; Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Iwate Medical University School of Medicine, Department of Radiology (Japan)

    2016-02-15

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

  2. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    International Nuclear Information System (INIS)

    Tamura, Akio; Kato, Kenichi; Suzuki, Michiko; Sone, Miyuki; Tanaka, Ryoichi; Nakasato, Tatsuhiko; Ehara, Shigeru

    2016-01-01

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC

  3. Interventional Radiology Management of a Ruptured Lumbar Artery Pseudoaneurysm after Cryoablation and Vertebroplasty of a Lumbar Metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Aldo Victor; Arrigoni, Francesco, E-mail: arrigoni.francesco@gmail.com [Ospedale San Salvatore, Department of Radiology (Italy); Bruno, Federico [University of L’Aquila, Department of Biotechnological and Applied Clinical Sciences (Italy); Carducci, Sergio; Varrassi, Marco; Zugaro, Luigi [Ospedale San Salvatore, Department of Radiology (Italy); Barile, Antonio; Masciocchi, Carlo [University of L’Aquila, Department of Biotechnological and Applied Clinical Sciences (Italy)

    2017-05-15

    We describe the management of a complication (a lumbar artery pseudoaneurysm and its rupture) after combined procedure (cryoablation and vertebroplasty) on a lumbar (L2) metastasis from renal cell carcinoma. Review of the literature is also presented with discussion about the measures to be taken to prevent these types of complications.

  4. Interventional and surgical treatment of a hemothorax caused by a ruptured vertebral artery in a patient with neurofibromatosis type I

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hoon; Kim, Dong Hun; Kim, Dong Hyun; Seo, Hong Joo [Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2014-04-15

    We report a case of a massive hemothorax arising from a ruptured vertebral artery aneurysm in a patient with neurofibromatosis type 1 suffering from sudden onset of dyspnea. The vertebral artery aneurysm was treated with endovascular coil embolization. Then, an open thoracotomy was performed to evacuate the hematoma.

  5. Extrapeural locating method: significance in CT-guided transthoracic pulmonary biopsy

    International Nuclear Information System (INIS)

    Tang Guangjian; Wang Rengui; Liu Jianxin; Sun Jingtao

    2008-01-01

    Objective: To evaluate the usefulness of extrapleural locating method in CT-guided transthoracic pulmonary biopsy to prevent or reduce the size of peumothorax. Methods: One hundred and fifteen cases of CT-guided transthoracic pulmonary biopsy with the pulmonary lesions not in direct contact with the pleura were selected. Of 115 cases, 46 were performed with extrapleural locating method (EPL) and 69 cases with lesion edge locating method (LEL). Taking the maximum distance between the partial and visceral pleura (MPVD) measured on the CT image after the procedure as the index of the volume of pneumothorax. The incidence and volume of pneumothorax of both groups were compared and statistically analysed with R x C Chi-Square test. The retention time of the biopsy needle in the lung parenchyma of the two group was documented and the average time was calculated in each group. Results: The incidence of pneumothorax was 45.7% (21/46), median 0.4 cm with EPL group, and 66.7% (46/69) and median 0.3cm with LEL group. When the distance between the lesion and pleura was equal or smaller than 2 cm (≤2cm), the incidence of pneumothorax was 39.4% (13/33) with EPL group and 73.2% (30/41) with LEL group, and the difference of incidence and volume of the pneumothorax between two groups was statistically significant(χ 2 =9.981, P=0.019). When the distance was larger than 2 cm (>2 cm), the incidence and volume of pneumothorax between two groups were not significant statistically. The average retention time of the biopsy needle in the lung parenchyma was (7.2 ± 1.8) s with EPL group and (58.3 ± 11.6) s with LEL group. Conclusion: The extrapleural locating method can reduce effectively the retention time of the biopsy needle in the lung parenchyma and the incidence and volume of pneumothorax in CT-guided transthoracic pulmonary biopsy. (authors)

  6. Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy

    Science.gov (United States)

    Zeng, L-C; Du, Y; Yang, H-F; Xie, M-G; Liao, H-Q; Zhang, Y-D; Li, L; Wang, Q; Hu, L

    2015-01-01

    Objective: To evaluate the efficacy of aspiration in an opposite position to deal with pneumothorax after CT-guided lung biopsy. Methods: A retrospective study was developed involving 210 patients with pneumothorax who had undergone CT-guided percutaneous core biopsies from January 2012 to March 2014 for various pulmonary lesions. Asymptomatic patients with minimal pneumothorax were treated conservatively. Simple manual aspiration was performed for symptomatic patients with minimal pneumothorax and for all patients with moderate to large pneumothorax. An opposite position aspiration was performed when simple manual aspiration failed. The efficacy of simple manual aspiration and the opposite position aspiration was observed. Results: Among 210 patients with pneumothorax, 128 (61.0%) asymptomatic patients with minimal pneumothorax were treated conservatively. The remaining 82 were treated with attempted simple manual aspiration. Out of these 82 patients, simple manual aspiration was successful in 58 (70.7%, 58/82) cases. The complete and partial regression rates were 17.2% (10/58) and 82.8% (48/58), respectively. In the other 24 patients (29.3%, 24/82), simple aspiration technique was ineffective. An opposite position (from prone to supine or vice versa) was applied, and a new biopsy puncture site was chosen for reaspiration. This procedure was successful in 22 patients but not in 2 patients who had to have a chest tube insertion. The complete and partial regression rates were 25.0% (6/24) and 66.7% (16/24), respectively. Applying the new method, the total effective rate of aspiration improved significantly from 70.7% (58/82) to 97.6% (80/82). Conclusion: The opposite position aspiration can be safe, effective and minimally invasive treatment for CT-guided lung biopsy-induced pneumothorax thus reducing the use of chest tube significantly. Advances in knowledge: (1) Opposite position aspiration can elevate the success rate of aspiration significantly (from 70.7% to 97

  7. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  8. CT-guided percutaneous vertebroplasty for the treatment of metastases in the cervical spine

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Zhentang; Zuo Changjing; Shao Chenwei; Chen Wei; Lv Taozhen; Dong Aisheng

    2009-01-01

    Objective: To assess the clinical efficacy and complications of CT-guided percutaneous vertebroplasty in the treatment of metastases of the cervical spine, and to discuss the proper needle path for different cervical vertebra. Methods: CT-guided percutaneous vertebroplasty was performed in 17 patients with cervical vertebral metastatic neoplasm, and the results of the treatment were retrospectively analyzed. Close observation was carded out after the procedure and a follow-up of 3-17 months was conducted. A comparison of the visual analogue pain scale (VAS) and Frankel's classification between pre-and post- operation was made. The occurrence of complications was recorded. The optimal needle path was summarized. Results: (1) The successful puncture was achieved in all 17 cases. The needle pathway included: the front of carotid sheath (n=4), between carotid sheath and vertebral artery (n=11) and behind the vertebral artery and carotid sheath (n=2). (2) Before the procedure the VAS was 7.24 ± 1.01, and at the time of one hour, one week and three months after the procedure it was decreased to 3.24 ± 1.09, 2.40 ± 0.80 and 1.82 ± 0.53 respectively. Wilcoxon signed-rank test showed that the difference in VAS between pre-and post- operation was statistically significant (T=76.5, P 2 =4.52, P=0.033 and P<0.05 when Kruskal-Wallis test was adopted. (3) CT scanning immediately after the procedure showed that slight leakage of cement to the adjacent disc, epidural fat, parosteal tissue or to the needle path occurred in 35.3% with no serious complications. In a follow-up period of 3-17 months, the metastatic lesions remained stable in 14 cases (82.4%). Conclusion: (1) The optimal needle path for upper cervical vertebrae is posterolateral transpedicular approach while for the lower cervical vertebrae it is more reasonable to puncture via the front carotid sheath or between carotid sheath and vertebral artery. Nevertheless, the puncture pathway should be devised individually

  9. Rupture disc

    International Nuclear Information System (INIS)

    Newton, R.G.

    1977-01-01

    The intermediate heat transport system for a sodium-cooled fast breeder reactor includes a device for rapidly draining the sodium therefrom should a sodium-water reaction occur within the system. This device includes a rupturable member in a drain line in the system and means for cutting a large opening therein and for positively removing the sheared-out portion from the opening cut in the rupturable member. According to the preferred embodiment of the invention the rupturable member includes a solid head seated in the end of the drain line having a rim extending peripherally therearound, the rim being clamped against the end of the drain line by a clamp ring having an interior shearing edge, the bottom of the rupturable member being convex and extending into the drain line. Means are provided to draw the rupturable member away from the drain line against the shearing edge to clear the drain line for outflow of sodium therethrough

  10. 18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Imperiale, Alessio, E-mail: alessio.imperiale@chru-strasbourg.fr; Namer, Izzie Jacques, E-mail: izzie.jacques.namer@chru-strasbourg.fr [Hôpital de Hautepierre (Hôpitaux Universitaires de Strasbourg, HUS), Department of Biophysics and Nuclear Medicine (France); Bachellier, Philippe, E-mail: philippe.bachellier@chru-strasbourg.fr [Hôpital de Hautepierre (Hôpitaux Universitaires de Strasbourg, HUS), Hepato-Pancreato-Biliary Surgery and Liver Transplantation (France); Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2016-09-15

    AimTo review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs).Materials and MethodsThree patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; <3 cm) on 18F-FDOPA PET/CT; poor lesion visualisation on US, CT, and MR; and ongoing symptoms. Procedures were performed in an interventional PET/CT scanner under general anaesthesia using a split-dose protocol. Lesion characteristics, procedural duration and technical success (accurate probe placement and post-procedural ablation-zone photopaenia), complications, patient and operator dose, and clinical outcomes were evaluated.ResultsThirteen liver metastases (mean size 11.4 mm, range 8–16) were treated in three patients (two presented with “carcinoid syndrome”). Technical success was 100 % with a mean procedural duration of 173.3 min (range 90–210) and no immediate complications. Mean patient dose was 2844 mGy·cm (range 2104–3686). Operator and radiographer doses were acceptable other than the operator’s right hand in the first case (149 µSv); this normalised in the second case. There was no local tumour or extra-hepatic disease progression at mid-term follow-up (mean 12.6 months; range 6–20); however, two cases progressed with new liver metastases at different sites. There was 100 % clinical success (n = 2) in resolving carcinoid syndrome symptoms.Conclusion18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.

  11. CT-guided fixation of sacral fractures and sacrolilac joint disruptions

    International Nuclear Information System (INIS)

    Nelson, D.W.; Duwelius, P.

    1990-01-01

    Placement of sacral fixation screws at surgery is performed blindly (ie, by palpation). The authors of this paper employed CT to localize the screw between the neutral foramina and anterior sacral cortex and to decrease the morbidity associated with general anesthesia and surgery. Six patients underwent CT-guided sacral fixation performed by means of the 7.0 mm A0 cannulated screw system. All patients had reducible vertical sacral fractures or sacroiliac joint disruptions. Following placement of an epidural catheter for anesthesia, patients were scanned in the prone or decubitus position. Measurements for placement of the guide pin were made from the preliminary scans. Following CT confirmation of satisfactory guide pin placement across the fracture, the screw track was drilled, the screw length was determined, and the fixation screw was placed in position. A CT scan was obtained to evaluate the final position of the screw

  12. Application of electronic endoscopy and CT-guided stereotactic aspiration to intracerebral hematoma

    International Nuclear Information System (INIS)

    Kusaka, Masahiko

    1991-01-01

    According to the development of computer technology and operative instruments, stereotactic neurosurgery became more precise, and extended as its indication. CT-guided stereotactic aspiration of intracerebral hematoma is superior operative procedure with rare complications. Using Stereotactic Aqua-Stream and Aspirator at the same time, hematoma was removed sufficiently. However, stereotactic neurosurgery had a major weak points, it was a blind operation. An endoscope (FVS-1000, M and M Co.) and SASA (Marui Medical Co.) were applied in 5 cases of intracerebral hematoma. In physiological saline, the endoscope had 32.9 deg angle of visual field, 1 mm - 25 mm depth of vision, and 16 pair/mm resolution. It was excellent ability for neurosurgery. Using for clinical cases, the bloody fluid in the hematoma cavity disturbed visibility. It was a difficult problem. Influence of bloody fluid concentration to depth of vision and resolution was investigated, and method of making clear visibility was described. (author)

  13. Clinical evaluation of CT-guided stereotaxic evacuation of hypertensive intracerebral hematomas

    International Nuclear Information System (INIS)

    Kimura, Masato; Yoshinaga, Shiya; Nakayama, Yoshiya; Hirakawa, Toshihiko; Tanaka, Akira; Tomonaga, Masamichi

    1989-01-01

    The clinical results of CT-guided stereotaxic evacuation of hypertensive intracerebral hematomas which had been done in our department during the last 16 months were evaluated. They included 18 cases; 8 of thalamic, 9 of putaminal and one of cerebellar hematoma. The patients were 11 males and 7 females, with an average age of 57. The time interval from oneset to surgery was 1-21 days, 9.5 days on average. The hematoma volume estimated on a CT scan was 6-35 ml and the average rate of hematoma removal by surgery was 75%. Intraoperative monitoring with ultrasonography and postoperative infusion of Urokinase increased the removal rate. In 14 cases, the mental ability and motor function improved within days after surgery and rehabilitation was started within a short period. However, the recovery in aged people was generally poor. Rebleeding occurred postoperatively in one case, necessitating a subsequent craniotomy. (author)

  14. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  15. CT-guided percutaneous acetic acid injection therapy for liver metastasis

    International Nuclear Information System (INIS)

    Yu Tongfu; Wang Dehang; Zhuang Zhenwu; Li Linxun; Shi Haibin

    2002-01-01

    Objective: To evaluate the efficacy of CT-guided percutaneous acetic acid injection (PAI) for liver metastasis. Methods: Thirty-five cases (40 lesions) with liver metastasis were treated with PAI. 4-10 ml of 30% acetic acid with 1 ml contrast media was injected into every lesion. PAI was performed twice a week, and repeated for 2 to 3 weeks. Results: The tumors shrunk in 23 lesions, and remained unchanged in 12 lesions. The efficiency was 87.5%. All cases were followed up for 3 months to 3 years. One year survival rates was 62.9% (22 cases), 2 years 40.0% (14 cases), and 3 years 22.9% (8 cases). Conclusion: PAI was an effective therapy for liver metastasis

  16. Cerebellar and brainstem infarction as a complication of CT-guided transforaminal cervical nerve root block

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, S. [The Royal National Orthopaedic Hospital NHS Trust, London (United Kingdom); Berman, J. [The Royal National Orthopaedic Hospital NHS Trust, Anaesthetic Department, London (United Kingdom); Connell, David A. [The Royal National Orthopaedic Hospital NHS Trust, Department of Radiology, London (United Kingdom)

    2007-05-15

    A 60-year-old man with a 4-year history of intractable neck pain and radicular pain in the C5 nerve root distribution presented to our department for a CT-guided transforaminal left C5 nerve root block. He had had a similar procedure on the right 2 months previously, and had significant improvement of his symptoms with considerable pain relief. On this occasion he was again accepted for the procedure after the risks and potential complications had been explained. Under CT guidance, a 25G spinal needle was introduced and after confirmation of the position of the needle, steroid was injected. Immediately the patient became unresponsive, and later developed a MR-proven infarct affecting the left vertebral artery (VA) territory. This is the first report of a major complication of a cervical root injection under CT guidance reported in the literature. We present this case report and the literature review of the potential complications of this procedure. (orig.)

  17. Brachial Plexus Injury from CT-Guided RF Ablation Under General Anesthesia

    International Nuclear Information System (INIS)

    Shankar, Sridhar; Sonnenberg, Eric van; Silverman, Stuart G.; Tuncali, Kemal; Flanagan, Hugh L.; Whang, Edward E.

    2005-01-01

    Brachial plexus injury in a patient under general anesthesia (GA) is not uncommon, despite careful positioning and, particularly, awareness of the possibility. The mechanism of injury is stretching and compression of the brachial plexus over a prolonged period. Positioning the patient within the computed tomography (CT) gantry for abdominal or chest procedures can simulate a surgical procedure, particularly when GA is used. The potential for brachial plexus injury is increased if the case is prolonged and the patient's arms are raised above the head to avoid CT image degradation from streak artifacts. We report a case of profound brachial plexus palsy following a CT-guided radiofrequency ablation procedure under GA. Fortunately, the patient recovered completely. We emphasize the mechanism of injury and detail measures to combat this problem, such that radiologists are aware of this potentially serious complication

  18. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  19. Cerebellar and brainstem infarction as a complication of CT-guided transforaminal cervical nerve root block

    International Nuclear Information System (INIS)

    Suresh, S.; Berman, J.; Connell, David A.

    2007-01-01

    A 60-year-old man with a 4-year history of intractable neck pain and radicular pain in the C5 nerve root distribution presented to our department for a CT-guided transforaminal left C5 nerve root block. He had had a similar procedure on the right 2 months previously, and had significant improvement of his symptoms with considerable pain relief. On this occasion he was again accepted for the procedure after the risks and potential complications had been explained. Under CT guidance, a 25G spinal needle was introduced and after confirmation of the position of the needle, steroid was injected. Immediately the patient became unresponsive, and later developed a MR-proven infarct affecting the left vertebral artery (VA) territory. This is the first report of a major complication of a cervical root injection under CT guidance reported in the literature. We present this case report and the literature review of the potential complications of this procedure. (orig.)

  20. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  1. CT-guided percutaneous cryoablation of osteoid osteoma in children: an initial study

    International Nuclear Information System (INIS)

    Wu, Bin; Xiao, Yue-Yong; Zhang, Xiao; Zhao, Lei; Carrino, John A.

    2011-01-01

    The purpose of this study was to evaluate the safety and efficacy of CT-guided percutaneous cryoablation for osteoid osteoma in children. This study was approved by the institutional ethics committee. From January 2007 to July 2008, six children (four boys, two girls, mean age 12.6 years old) with osteoid osteoma were treated with CT-guided percutaneous cryoablation. The procedures were carried out under conscious sedation and local anesthesia. CT guidance was used for procedural planning, instrument guidance, and monitoring. An argon-based cryoablation system was used. Each cryoablation included two freezing-thawing cycles. Follow-up was performed to assess technical and clinical outcome for a minimum of 12 months. A visual analog scale (VAS) was used to assess severity of pain pre- and post-procedure, and mean VAS for the group was compared pre- and post-procedure with a t-test. The mean clinical follow-up period was 28.7 months (ranging from 18 to 36 months). Cryoablation was technically and clinically successful for all patients. No major immediate or delayed complications were observed. Significant pain relief (P <0.05) was observed in all patients after operation. Mean VAS were 6.57 ± 0.55 pre-procedure and 0.57 ± 0.10 1 month post-procedure. Patients were allowed to fully bear their weight and function without limitation within 3 days after the procedure. Pain recurrence was not observed in any patient. Percutaneous cryoablation is safe and effective for the treatment of osteoid osteomas in children. Notably, this procedure can be accomplished without general anesthesia. (orig.)

  2. Treatment of aneurysmal bone cysts by percutaneous CT-guided injection of calcitonin and steroid

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Kattapuram, Susan V.; Huang, Ambrose J.; Simeone, F.J.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital, Department of Radiology Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States)

    2017-01-15

    To determine the efficacy and safety of percutaneous calcitonin and steroid injection in the treatment of aneurysmal bone cysts (ABCs). Our study was IRB-approved and HIPAA-compliant. We reviewed pre- and post-procedural imaging studies and medical records of all CT-guided percutaneous injections of ABCs with calcitonin and steroid performed at our institution between 2003 and 2015. Treatment success based on imaging was categorized as substantial (51-100 %), partial (1-50 %), or none (0 %) by comparing radiographs of the lesion before and after treatment. Our study group comprised 9 patients (7 female, 2 male; mean age 19 ± 5 (range 12-25) years). ABCs were located in the pubis (n = 3), femur (n = 2), and humerus/scapula/ilium/sacrum (n = 1 for each). One patient did not have any clinical or imaging follow-up. For the other 8 patients, clinical and imaging follow-up ranged from 1 to 93 months (mean 16 ± 29 months). One patient had two injections, and 1 patient had three injections. Six out of eight patients (75 %) had complete symptomatic relief and 2 patients (25 %) had partial symptomatic relief after initial injection. Imaging follow-up revealed substantial imaging response in 4 out of 8 patients (50 %). There was a partial imaging response in 2 patients (25 %) and no imaging response in 2 out of 8 patients (25 %), and all 4 of these patients had local recurrence. There were no complications. Percutaneous CT-guided injection of ABCs with calcitonin and steroid is a safe and effective treatment. Lack of imaging response may necessitate more aggressive treatment to minimize local recurrence. (orig.)

  3. CT-guided celiac plexus block with absolute alcohol : the anterior approach

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Jang, Young Ik; Kim, Jeong Hoi; Ym, Seong Hee; Lee, Jin Hee; Han, Young Min; Kim, Chong Soo; Choi, Ki Chul

    1997-01-01

    To evaluate the safety and efficacy of CT-guided celiac plexus block (CPB) using an anterior approach, and to determine the role of CT in this procedure. CPB was attempted in 15 patients(10 men and 5 women;mean age, 62.3 years) with intractable upper abdominal pain due to terminal malignancy of the pancreas, liver, bowel,and kidney. To permit an anterior approach, patients lied supine on the CT scan table during the procedure. One or two 21-guage needles were placed just anterior to the diaphragmatic crus at or between the levels of the celiac and superior mesenteric arteries and 10-40ml of 99.9% alcohol was injected. Pain relief following the procedure was assessed and pain was graded on a visual analogue scale (VAS) from 0 to 10. There were no technical failures and no neurologic or hemorrhagic complications. Abdominal pain during alcohol injection occurred in all patients, and transient hypotension in three. One patient with recurrent cancer of the pancreatic head died of sepsis five days after the procedure;the cause of sepsis was difficult to determine, but there was thought to be a biliary source of infection. Two days after block, 13 of 15 procedures(86.7%) had produced at least partial pain relief;in 12 patients, relief was good. With CT guidance, more directed positioning of the needle is possible, allowing alcohol to be deposited in specific ganglion areas. CT-guided celiac plexus block using an anterior approach was an easy and effective way of reducing intractable upper abdominal pain due to terminal malignancies. CT guidance allowed precise needle placement and a safer procedure

  4. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  5. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  6. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  7. CT-guided interstitial 125I seed implantation for intractable pelvic recurrence of rectal carcinomas

    International Nuclear Information System (INIS)

    Lin Zhenwen; Chu Hong; Kong Jian; Dou Yongchong

    2011-01-01

    Objective: To evaluate the therapeutic effect and safety of CT-guided interstitial 125 I seed implantation in treating intractable pelvic recurrence of rectal carcinomas. Methods: During the period from April 2010 to September 2010 CT-guided interstitial 125 I seed implantation was carried out in 11 patients with pelvic recurrence of rectal carcinoma which developed after the patients had received comprehensive treatments such as surgical resection, chemotherapy and/or radiotherapy. The clinical data were retrospectively analyzed. The clinical symptoms, the tumor size and the quality of life (QOL) before the treatment and at two and six months after the treatment were recorded, and the complications were observed. The results were compared. All the patients were followed up for six months. Results: At two and six months after the treatment, the improvement rate of the clinical symptoms was 100.0% (11/11) and 90.9% (10/11) respectively, while the effective reduction of the tumor size was 90.9% (10/11) and 81.8% (9/11) respectively. At two and six months after the treatment the QOL score was (56.0±3.66) and (54.4±5.41) respectively, both of which were higher than the QOL score determined before the treatment (42.5±6.93), the difference between them was statistically significant (P 125 I seed implantation has satisfactory short-term effect. This treatment is also quite safe and effective for patients who are unbearable to external radiation therapy due to the tissue dose restriction. (authors)

  8. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  9. CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection

    International Nuclear Information System (INIS)

    Klass, Darren; Marshall, Tom; Toms, Andoni

    2009-01-01

    Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heated to 90 C for 2 min for two cycles by using a Cosman SMK TC-10 RF electrode. This was preceded by a bolus of room temperature sterile water (10 ml) injected through a 26G curved spinal needle into the exit foramen and adjacent epidural space for neuroprotection. The age of the patient, sex, lesion location, biopsy results and complications were recorded. All the biopsies (n = 7) demonstrated histological features of osteoid osteoma. All the procedures were technically successful. Clinical success was assessed up to 3 years post procedure. There was an 85% clinical success rate (6 of the 7 patients), with recurrence of a lesion at 6 months, necessitating a repeat procedure (successful). CT-guided percutaneous RF ablation of spinal osteoid osteoma preceded by bolus of sterile water, injected through a spinal needle into the exit foramen and adjacent epidural space for neuroprotection, is a safe and effective procedure. (orig.)

  10. Globe Rupture

    Directory of Open Access Journals (Sweden)

    Reid Honda

    2017-07-01

    Full Text Available History of present illness: A 46-year-old male presented to the emergency department (ED with severe left eye pain and decreased vision after tripping and striking the left side of his head on the corner of his wooden nightstand. The patient arrived as an inter-facility transfer for a suspected globe rupture with a protective eye covering in place; thus, further physical examination of the eye was not performed by the emergency physician in order to avoid further leakage of aqueous humor. Significant findings: The patient’s computed tomography (CT head demonstrated a deformed left globe, concerning for ruptured globe. The patient had hyperdense material in the posterior segment (see green arrow, consistent with vitreous hemorrhage. CT findings that are consistent with globe rupture may include a collapsed globe, intraocular air, or foreign bodies. Discussion: A globe rupture is a full-thickness defect in the cornea, sclera, or both.1 It is an ophthalmologic emergency. Globe ruptures are almost always secondary to direct perforation via a penetrating mechanism; however, it can occur due to blunt injury if the force generated creates sufficient intraocular pressure to tear the sclera.2 Globes most commonly rupture at the insertions of the intraocular muscles or at the limbus. They are associated with a high rate of concomitant orbital floor fractures.2,3 Possible physical examination findings include a shallow anterior chamber on slit-lamp exam, hyphema, and an irregular “teardrop” pupil. Additionally, a positive Seidel sign, which is performed by instilling fluorescein in the eye and then examining for a dark stream of aqueous humor, is indicative of a globe rupture.4 CT is often used to assess for globe rupture; finds of a foreign body, intraocular air, abnormal contour or volume of the globe, or disruption of the sclera suggest globe rupture.2 The sensitivity of CT scan for diagnosis of globe rupture is only 75%; thus, high clinical

  11. CT-guided radioactive 125I-seed implantation for the treatment of pancreatic carcinoma: a clinical observation of 19 cases

    International Nuclear Information System (INIS)

    Lu Jian; Zheng Yunfeng; Zhang Huan; Wang Zhongmin; Chen Kemin

    2010-01-01

    Objective: To explore the dynamic changes of serum tumor markers after CT-guided radioactive 125 I-seed implantation treatment in patients with pancreatic carcinoma and to assess the therapeutic effectiveness of 125 I-seed implantation. Methods: CT-guided radioactive 125 I-seed implantation was performed in 19 patients with unresectable advanced pancreatic cancer. Treatment planning system was used to reconstruct 3-dimentional images of the tumor, and the quantity and distribution of 125 I-seeds to be implanted were thus determined. Under CT guidance 125 I-seeds were embedded into pancreatic cancer. Before and after the 125 I-seed implantation the levels of serum tumor markers, including CEA, CA19-9 and CA50, were determined by using radioimmunoassay method. The clinical effects were observed and the therapeutic results were statistically analyzed. Results: The pain stared to be relieved 2 to 5 days after implantation. The total effective rate (CR + PR) at one and three months after treatment was 68.42% (13 /19) and 63.16% (12 /19) respectively. One month after 125 I-seed implantation, the levels of serum CEA, CA19-9 and CA50 were significantly different to that determined before implantation in all cases (P 125 I-seed implantation is a safe and effective interventional treatment for advanced pancreatic cancer with reliable short-term result and remarkable pain-relieving effect. Moreover, this therapy can significantly lower the levels of many serum tumor markers, which play some suggestive roles in evaluating the clinical curativeness. (authors)

  12. Complications in CT-guided, semi-automatic coaxial core biopsy of potentially malignant pulmonary lesions; Komplikationen bei CT-gesteuerter, koaxialer Stanzbiopsie malignomverdaechtiger Lungenherde in halbautomatischer Technik

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R. [Klinik Loewenstein (Germany). Dept. of Radiology; Seebacher, G.; Enderes, B.; Kugler, G.; Graeter, T.P. [Klinik Loewenstein (Germany). Dept. of Thoracic and Vascular Surgery; Fischer, J.R. [Klinik Loewenstein (Germany). Dept. of Oncology

    2015-08-15

    Histological verification of pulmonary lesions is important to ensure correct treatment. Computed tomographic (CT) transthoracic core biopsy is a well-established procedure for this. Comparison of available studies is difficult though, as technical and patient characteristics vary. Using a standardized biopsy technique, we evaluated our results for CT-guided coaxial core biopsy in a semi-automatic technique. Within 2 years, 664 consecutive transpulmonary biopsies were analyzed retrospectively. All interventions were performed using a 17/18G semi-automatic core biopsy system (4 to 8 specimens). The incidence of complications and technical and patient-dependent risk factors were evaluated. Comparing the histology with the final diagnosis, the sensitivity was 96.3 %, and the specificity was 100 %. 24 procedures were not diagnostic. In all others immunohistological staining was possible. The main complication was pneumothorax (PT, 21.7 %), with chest tube insertion in 6 % of the procedures (n = 40). Bleeding without therapeutic consequences was seen in 43 patients. There was no patient mortality. The rate of PT with chest tube insertion was 9.6 % in emphysema patients and 2.8 % without emphysema (p = 0.001). Smokers with emphysema had a 5 times higher risk of developing PT (p = 0.001). Correlation of tumor size or biopsy angle and the risk of PT was not significant. The risk of developing a PT was associated with an increasing intrapulmonary depth of the lesion (p = 0.001). CT-guided, semiautomatic coaxial core biopsy of the lung is a safe diagnostic procedure. The rate of major complications is low, and the sensitivity and specificity of the procedure are high. Smokers with emphysema are at a significantly higher risk of developing pneumothorax and should be monitored accordingly.

  13. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  14. Ruptured Spleen

    Science.gov (United States)

    ... be caused by various underlying problems, such as mononucleosis and other infections, liver disease, and blood cancers. ... cause a ruptured spleen. For instance, people with mononucleosis — a viral infection that can cause an enlarged ...

  15. CT-guided stereotaxic implantation of Ommaya reservoir for cystic brain tumor

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Nobukazu; Niizuma, Hiroshi; Johkura, Hidefumi; Katoh, Seiya; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-02-01

    We report the use of CT-guided stereotaxic system to implant Ommaya reservoir in 26 patients with cystic brain tumors consisting of 16 gliomas, 3 craniopharyngiomas, 3 metastatic brain tumors and 5 other and unknown pathologies, on the way of their biopsy. The entire procedure was carried out in the CT room using Leksell's CT stereotaxic system. In 24 cases with supratentorial tumors, it was at the option of the operator to take any approach such as frontal, posterior temporal and parietal approaches. Especially in 3 cases of craniopharyngioma, we inserted the tube into their cyst directly so that the ventricle should not be open to the cyst. Also in cases of a pontine glioma and a C-P angle metastatic tumor, we used retromastoid approach to the posterior fossa by making patient's heads turned about 30 to 40 deg to contralateral side of the approach, with slight flexion of the neck. Minimal bleeding occurred during operation in one case, however, it showed no clinical symptoms. Advantages of this method are as follows: Operative invasion is minimal; The surgeon can check the course of the cannula and position of the tip of Ommaya tube even at operation, and can modify it, if necessary.

  16. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  17. CT-guided stereotaxic implantation of Ommaya reservoir for cystic brain tumor

    International Nuclear Information System (INIS)

    Nakasato, Nobukazu; Niizuma, Hiroshi; Johkura, Hidefumi; Katoh, Seiya; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    We report the use of CT-guided stereotaxic system to implant Ommaya reservoir in 26 patients with cystic brain tumors consisting of 16 gliomas, 3 craniopharyngiomas, 3 metastatic brain tumors and 5 other and unknown pathologies, on the way of their biopsy. The entire procedure was carried out in the CT room using Leksell's CT stereotaxic system. In 24 cases with supratentorial tumors, it was at the option of the operator to take any approach such as frontal, posterior temporal and parietal approaches. Especially in 3 cases of craniopharyngioma, we inserted the tube into their cyst directly so that the ventricle should not be open to the cyst. Also in cases of a pontine glioma and a C-P angle metastatic tumor, we used retromastoid approach to the posterior fossa by making patient's heads turned about 30 to 40 deg to contralateral side of the approach, with slight flexion of the neck. Minimal bleeding occurred during operation in one case, however, it showed no clinical symptoms. Advantages of this method are as follows: Operative invasion is minimal; The surgeon can check the course of the cannula and position of the tip of Ommaya tube even at operation, and can modify it, if necessary. (author)

  18. CT-guided iodine-125 seed permanent implantation for recurrent head and neck cancers

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yu L; Meng, Na; Wang, Jun J; Jiang, Ping [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China); Yuan, Hui SH; Liu, Chen [Department of Radiology, Peking University Third Hospital, Beijing, 100191 (China); Qu, Ang; Yang, Rui J [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China)

    2010-07-30

    To investigate the feasibility, and safety of {sup 125}I seed permanent implantation for recurrent head and neck carcinoma under CT-guidance. A retrospective study on 14 patients with recurrent head and neck cancers undergone {sup 125}I seed implantation with different seed activities. The post-plan showed that the actuarial D90 of {sup 125}I seeds ranged from 90 to 218 Gy (median, 157.5 Gy). The follow-up was 3 to 60 months (median, 13 months). The median local control was 18 months (95% CI, 6.1-29.9 months), and the 1-, 2-, 3-, and 5- year local controls were 52%, 39%, 39%, and 39%, respectively. The 1-, 2-, 3-, and 5- survival rates were 65%, 39%, 39% and 39%, respectively, with a median survival time of 20 months (95% CI, 8.7-31.3 months). Of all patients, 28.6% (4/14) died of local recurrence, 7.1% (1/14) died of metastases, one patient died of hepatocirrhosis, and 8 patients are still alive to the date of data analysis. CT-guided {sup 125}I seed implantation is feasible and safe as a salvage or palliative treatment for patients with recurrent head and neck cancers.

  19. The experimental study of CT-guided hepatocyte growth factor gene therapy for cerebral ischemic diseases

    International Nuclear Information System (INIS)

    Zhang Xiaobo; Jin Zhengyu; Li Mingli; Wang Renzhi; Li Guilin; Kong Yanguo; Wang Jianming; Gao Shan; Guan Hongzhi; Wang Detian; Luo Yufeng

    2006-01-01

    Objectives: To investigate the feasibility of CT guided hepatocyte growth factor (HGF) gene therapy for cerebral ischemic diseases. Methods: Human HGF cDNA was ligated to pIRES 2 -EGFP vector. The recombinant plasmid was transfected into the penumbra tissue with liposome, guided by CT perfusion images. After seven days of transfer with recombinant plasmid, the cut sections of rat brain tissues of the treated and control groups were analyzed including immunohistochemistry, vessel count, cerebral blood flow and infarct volume etc. in order to investigate HGF gene expression and biological effect. Results: Enzymatic digestion and electrophoresis confirmed that HGF fragments had been correctly cloned into the space between the BamH I and Sal I sites of pIRES 2 -EGFP. After 7 days of HGF gene transfection, expression of HGF in transfected neurocytes of treated group was observed with immunohistochemistry. The number of vessels in penumbra tissues transfected with HGF vectors and the CBF measured by perfusion CT all were significantly increased than those of the controls (P 2 -EGFP-HGF complexes can transfect the penumbra tissues and definitely express HGF protein. The HGF gene products can stimulate angiogenesis, promote collateral circulation formation and reduce infarct volume in vivo and therefore is beneficial to the treatment of cerebral ischemia. (authors)

  20. CT-guided radiolabelled aerosol studies for assessing pulmonary impairment in children with bronchiectasis

    International Nuclear Information System (INIS)

    Pifferi, M.; Baldini, M.; Caramella, D.; Bartolozzi, C.; Di Mauro, M.; Cangiotti, A.M.

    2000-01-01

    Objective. To determine whether CT-guided mucociliary clearance studies allow differentiation between bronchiectasis associated with primary ciliary dyskinesia (PCD) and those unrelated to congenital or genetically transmitted defects. Materials and methods. Fifteen children aged 4-18 years with a CT diagnosis of bronchiectasis were included in the study. Six had PCD, while in nine cases no congenital disorder was demonstrated. Results. CT showed bronchiectasis in 26 (29 %) of 90 lung regions. Radiolabelled aerosol studies were conducted globally for each lung and on the regions affected by bronchiectasis. Global half-time of activity (t 1/2 ) values of patients with PCD were significantly higher (P 1/2 values. Patients with bronchiectasis unrelated to congenital disorders showed significantly higher regional t 1/2 values in the affected regions with respect to the corresponding global pulmonary t 1/2 (P < 0.06). Conclusions. The combination of morphological CT information with functional data concerning the clearance of radiolabelled aerosol adds to our understanding of pulmonary impairment in children with bronchiectasis. In particular, regional studies allow the recognition of different mucociliary clearance patterns in bronchiectasis associated with PCD and those unrelated to congenital or genetically transmitted defects. (orig.)

  1. Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

    International Nuclear Information System (INIS)

    Permpongkosol, Sompol; Link, Richard E.; Kavoussi, Louis R.; Solomon, Stephen B.

    2008-01-01

    During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0 o and sub-0 o C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0 o C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage

  2. CT-guided unilateral thalamotomy with macroelectrode mapping for the treatment of Parkinson's disease

    International Nuclear Information System (INIS)

    Valalik, I.; Julow, J.; Sagi, S; Solymosi, D.

    2001-01-01

    Objective. To evaluate the effect of unilateral thalamotomy in patients with Parkinson's disease. Methods. The junction of the ventralis oralis posterior and ventralis intermedius nuclei targeted under CT-guidance, and confirmed by impedance recording and macrostimulation. Results. At the 6-month assessment the tremor has been completely abolished in 37 patients (82.2 %), and reduced in 6 patients (13.3 %). The unified Parkinson's disease rating scale tremor score decreased by 92.5 %, rigidity improved by 65.9 %. Axial symptoms and bradykinesia showed smaller improvement. The levodopa and anti-cholinergic medication significantly reduced. An improvement in the quality of life measured by the Parkinson's disease questionnaire (PDQ-39) has been observed. The dimensions of mobility, activities of daily living, emotional well being, and Stigma were significantly (P < 0.05) better, other changes were not significant. The single index improved from 47.8 ± 7.8 to 28.9 ± 6.3. Transient complications noted in 9 patients (20 %), mild persistent morbidity observed in 3 patients (6.7 %). At the 1, 2 and 3-year follow-up neither contralateral tremor, rigidity, nor bradykinesia progression was statistically significant. Conclusions. CT-guided thalamotomy with macro-electrode mapping provides a safe, effective and long lasting control of tremor and rigidity, reduces the need for medication, and improves the quality of life. (author)

  3. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  4. CT-guided percutaneous ethanol injection in the treatment of thyroid adenoma

    International Nuclear Information System (INIS)

    Zheng Jiasheng; Zhao Xia; Cui Xiongwei; Li Hua

    2001-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous ethanol injection (CT-PEI) in the treatment of thyroid adenoma. Methods: Fifty-four patients with 73 nodules were included in the study. Thyroid adenoma was confirmed by pathology. The serum level T3, T4 and TSH were normal in all cases. CT-PEI (0.3-2.5 ml ethanol/cm 3 nodular tissue) was given for 115 times (mean 1.58 +- 0.78 times/nodule). Results: Complete cure was observed in 37 nodules (50.7%). In 28 nodules (38.3%) volume reduction was greater than 80%. A significant nodule reduction (50%-80%) was observed in 7 nodules. Only 1 (1.4%) nodule volume reduction was 28.9%. Apart from 1 case of transient dysphonia and 2 cases of mild pain and burning sensation, no side effect was observed. Conclusion: CT-PEI is a safe and effective therapeutic procedure with few side effects for thyroid adenoma

  5. CT-Guided Biopsy in Suspected Spondylodiscitis--The Association of Paravertebral Inflammation with Microbial Pathogen Detection.

    Directory of Open Access Journals (Sweden)

    Daniel Spira

    Full Text Available To search for imaging characteristics distinguishing patients with successful from those with futile microbiological pathogen detection by CT-guided biopsy in suspected spondylodiscitis.34 consecutive patients with suspected spondylodiscitis underwent CT-guided biopsy for pathogen detection. MR-images were assessed for inflammatory infiltration of disks, adjacent vertebrae, epidural and paravertebral space. CT-images were reviewed for arrosion of adjacent end plates and reduced disk height. Biopsy samples were sent for microbiological examination in 34/34 patients, and for additional histological analysis in 28/34 patients.Paravertebral infiltration was present in all 10/10 patients with positive microbiology and occurred in only 12/24 patients with negative microbiology, resulting in a sensitivity of 100% and a specificity of 50% for pathogen detection. Despite its limited sensitivities, epidural infiltration and paravertebral abscesses showed considerably higher specificities of 83.3% and 90.9%, respectively. Paravertebral infiltration was more extensive in patients with positive as compared to negative microbiology (p = 0.002. Even though sensitivities for pathogen detection were also high in case of vertebral and disk infiltration, or end plate arrosion, specificities remained below 10%.Inflammatory infiltration of the paravertebral space indicated successful pathogen detection by CT-guided biopsy. Specificity was increased by the additional occurrence of epidural infiltration or paravertebral abscesses.

  6. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    Science.gov (United States)

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (Pstrategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  7. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  8. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  9. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell [Guy' s and St. Thomas' Hospitals, Department of Radiology, London (United Kingdom)

    2014-07-15

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  10. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Groezinger, Gerd; Maurer, Michael; Grosse, Ulrich; Horger, Marius; Nikolaou, Konstantin; Syha, Roland [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lauer, Ulrich M. [University of Tuebingen, Internal Medicine I, Department of Gastroenterology, Hepatology and Infectious disease, Tuebingen (Germany)

    2016-12-15

    Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. (orig.)

  11. [Clinical value of CT-guided high frequency-induced thermotherapy as a treatment for intrahepatic cholangiocarcinoma].

    Science.gov (United States)

    Fan, Wei-Jun; Zhang, Liang; Gu, Yang-Kui; Wang, Li-Gang; Ouyang, Yu-Shu

    2008-07-01

    To evaluate the therapeutic effect of CT-guided high frequency-induced thermotherapy (HiTT) for intrahepatic cholangiocarcinoma. Seventeen patients of intrahepatic cholangiocarcinoma with 21 lesions underwent comprehensive treatment with HiTT as the principle approach. As to the patients with obstructive jaundice, percutaneous trans-hepatic cholangial drainage (PTCD) or bile duct endoprosthesis placement was performed first to improve the liver function, then HiTT was performed; and patients without obstructive jaundice underwent CT-guided HiTT directly, 1-2 weeks later, chemotherapy was given for 4 - 6 courses. CT scan 1 week after HiTT showed a short-term achievement rate of 100% (17/17), and the single puncture in situ ablation rate was 76.1% (16/21). The average life span in the near future was 13.5 months. The adverse effects included topo-bleeding, pain after procedure, liver function damage, defervescence, etc. All the patients recovered after symptomatic treatment. The clinical value of CT-guided HiTT for intrahepatic cholangiocarcinoma is obvious.

  12. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    International Nuclear Information System (INIS)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell

    2014-01-01

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  13. Design and validation of a CT-guided robotic system for lung cancer brachytherapy.

    Science.gov (United States)

    Dou, Huaisu; Jiang, Shan; Yang, Zhiyong; Sun, Luqing; Ma, Xiaodong; Huo, Bin

    2017-09-01

    Currently, lung brachytherapy in clinical setting is a complex procedure. Operation accuracy depends on accurate positioning of the template; however, it is difficult to guarantee the positioning accuracy manually. Application of robotic-assisted systems can simplify the procedure and improve the manual positioning accuracy. Therefore, a novel CT-guided robotic system was developed to assist the lung cancer brachytherapy. A four degree-of-freedom (DOF) robot, controlled by a lung brachytherapy treatment planning system (TPS) software, was designed and manufactured to assist the template positioning. Target position of the template can be obtained from the treatment plan, thus the robot is driven to the target position automatically. The robotic system was validated in both the laboratory and the CT environment. In laboratory environment, a 3D laser tracker and an inertial measurement unit (IMU) were used to measure the mechanical accuracy in air, which includes positioning accuracy and position repeatability. Working reliability was also validated in this procedure by observing the response reliability and calculating the position repeatability. Imaging artifacts and accuracy of the robot registration were validated in the CT environment by using an artificial phantom with fiducial markers. CT images were obtained and used to test the image artifact and calculate the registration accuracy. Phantom experiments were conducted to test the accuracy of needle insertion by using a transparent hydrogel phantom with a high imitation artificial phantom. Also, the efficiency was validated in this procedure by comparing time costs in manual positioning with robotic positioning under the same experimental conditions. The robotic system achieved the positioning accuracy of 0.28 ± 0.25 mm and the position repeatability of 0.09 ± 0.11 mm. Experimental results showed that the robot was CT-compatible and responded reliably to the control commands. The mean registration accuracy

  14. The role of CT-guided percutaneous drainage of loculated air collections: an institutional experience.

    Science.gov (United States)

    Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A

    2015-10-01

    The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.

  15. Clinical Outcomes of Patients Receiving Integrated PET/CT-Guided Radiotherapy for Head and Neck Carcinoma

    International Nuclear Information System (INIS)

    Vernon, Matthew R.; Maheshwari, Mohit; Schultz, Christopher J.; Michel, Michelle A.; Wong, Stuart J.; Campbell, Bruce H.; Massey, Becky L.; Wilson, J. Frank; Wang Dian

    2008-01-01

    Purpose: We previously reported the advantages of 18 F-fluorodeoxyglucose-positron emission tomography (PET) fused with CT for radiotherapy planning over CT alone in head and neck carcinoma (HNC). The purpose of this study was to evaluate clinical outcomes and the predictive value of PET for patients receiving PET/CT-guided definitive radiotherapy with or without chemotherapy. Methods and Materials: From December 2002 to August 2006, 42 patients received PET/CT imaging as part of staging and radiotherapy planning. Clinical outcomes including locoregional recurrence, distant metastasis, death, and treatment-related toxicities were collected retrospectively and analyzed for disease-free and overall survival and cumulative incidence of recurrence. Results: Median follow-up from initiation of treatment was 32 months. Overall survival and disease-free survival were 82.8% and 71.0%, respectively, at 2 years, and 74.1% and 66.9% at 3 years. Of the 42 patients, seven recurrences were identified (three LR, one DM, three both LR and DM). Mean time to recurrence was 9.4 months. Cumulative risk of recurrence was 18.7%. The maximum standard uptake volume (SUV) of primary tumor, adenopathy, or both on PET did not correlate with recurrence, with mean values of 12.0 for treatment failures vs. 11.7 for all patients. Toxicities identified in those patients receiving intensity modulated radiation therapy were also evaluated. Conclusions: A high level of disease control combined with favorable toxicity profiles was achieved in a cohort of HNC patients receiving PET/CT fusion guided radiotherapy plus/minus chemotherapy. Maximum SUV of primary tumor and/or adenopathy was not predictive of risk of disease recurrence

  16. CT-guided radiofrequency ablation of osteoid osteoma using a multi-tined expandable electrode system.

    Science.gov (United States)

    Costanzo, Alessandro; Sandri, Andrea; Regis, Dario; Trivellin, Giacomo; Pierantoni, Silvia; Samaila, Elena; Magnan, Bruno

    2017-10-18

    Radiofrequency ablation (RFA) is the gold standard for the treatment of symptomatic osteoid osteoma (OO) as RFA yields both a high success and low complication rate. It has been widely utilized over the years, but recurrences of OO after this treatment have been documented. These recurrences may be the result of various factors, including incomplete tumor ablation, and are significantly higher in lesions greater than 10 mm. Thus, the need to induce thermal ablation in a wider area led us to use a Multi-Tined Expandable Electrode System (MTEES). In this study we examined the efficacy and safety of RFA using a MTEES in symptomatic OO. Between January 2005 and June 2007, 16 patients with symptomatic OO were treated by CT-guided percutaneous RFA using a MTEES. The diameter of OO ranged from 6 to 15 mm (mean 10±2.6 mm). Patients were evaluated for clinical outcomes, complications and recurrence. Pain evaluation was assessed preoperatively, 2 weeks postoperatively and at last follow-up. Clinical follow-up was available for all patients at a mean of 84.3 months (range 73-96 months). Mean preoperative VAS score was 7.4 (range 5-9), two weeks after the procedure mean VAS score was 0.3 (range 0-1) with a mean change of -7.06 points (p<0.0001). At the last follow-up a complete relief from pain has been observed in all patients. No major and minor complications were observed nor recurrences. RFA using a MTEES has been effective, safe and reliable for the treatment of OOs. This system, by increasing the size of the necrosis, could be a viable alternative to the single needle electrode in lesions larger than 10 mm, reducing the risk of recurrence.

  17. Clinical efficacy of CT-guided 125I seed implantation therapy for advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Wang Zhongmin; Lu Jian; Gong Ju; Zheng Yunfeng; Zhang Liyun; Huang Gang; Chen Kemin

    2009-01-01

    Objective: To discuss the clinical efficacy of CT-guided radioactive 125 I seed implantation treatment for unresectable pancreatic cancer. Methods: Forty patients with inoperable pancreatic cancer were enrolled in this study, including 25 males and 15 females with an median age of 69 years (38-89 years). Treatment planning system (TPS) was used to reconstruct 3-dimensional images of pancreatic tumor and to define the quantity and distribution of 125 I seeds. The radioactivity of 125 I seeds was 0.5 - 0.8 mCi / seed. The seeds were implanted into pancreatic tumor under CT guidance at intervals of 1 cm and were kept away from vessels, pancreatic duct and other adjacent important organs. The tumor matched peripheral dose (MPD) was 60-140 Gy. The median amount of implanted 125 I seeds was 36 (18-68) in number. CT scan was performed immediately after the procedure to check the quality of the seeds. In addition, 10 patients received concurrent chemotherapy with arterial infusion of gemcitabin and 5-fluororacil (5-Fu) for 3 to 4 therapeutic courses. Results: The median diameter of the tumors was 4.9 cm. The follow-up period was 2 to 28 months. After the treatment the refractory pain was significantly relieved (P 125 I seed implantation is a safe, effective and minimally-invasive brachytherapy for unresectable pancreatic cancer with reliable short-term efficacy. It has an excellent anti-pain effect. The curative results can be further improved when chemotherapy is employed together. However, its long-term efficacy needs to be observed. (authors)

  18. CT -guided sclerotherapy for simple renal cysts: Value of ethanol concentration monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jin Hong; Du, Yong; Li, Yang; Yang, Han Feng; Xu, Xiao Xue; Zheng, Hou Jun [The Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2014-02-15

    The aim of our study was to evaluate the differences between sclerotherapy with and without ethanol concentration monitoring for the treatment of simple renal cysts. Sixty-seven patients with 70 simple renal cysts were randomly assigned to two groups in a 12-month prospective controlled trial. One group (group A) was treated with computed tomography (CT)-guided sclerotherapy without ethanol concentration monitoring (33 patients with 35 cysts), whereas the other group (group B) had ethanol concentration monitoring (34 patients with 35 cysts) during the procedure. Treatment outcomes between the two groups were compared 12 months later with follow-up ultrasound examination. After the 12-month follow-up period, the overall success rate was 74.3% in group A and 94.3% in group B (p = 0.022). The mean cyst size before and after treatment was 8.6 ± 2.0 cm and 2.3 ± 2.9 cm, respectively, in group A, and 8.4 ± 1.7 cm and 0.8 ± 1.9 cm, respectively, in group B. The final size of the cysts in group B was significantly smaller than that in group A (p = 0.015). The likelihood of treatment with ethanol concentration monitoring being successful was approximately 16 times higher than without ethanol concentration monitoring (p = 0.026; odds ratio = 15.7; 95% confidence interval: 1.38-179.49). There were no major complications in either group. Monitoring of Hounsfield units (HU) of ethanol by CT is an effective method in the treatment of simple renal cysts with ethanol sclerotherapy. The ethanol sclerotherapy procedure can be terminated at the point of clear fluid aspiration because the HU (-190) of CT scan corresponds to it.

  19. Percutaneous CT-guided radiofrequency ablation of solitary small renal masses. A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, C.C.; Fischer, S.; Strunk, H.; Meyer, C.; Thomas, D.; Willinek, W.A.; Schild, H. [Univ. Bonn (Germany). Dept. of Radiology; Hauser, S. [Univ. Bonn (Germany). Dept. of Urology; Nadal, J. [Univ. Bonn (Germany). Inst. for Medical Biometry; Wilhelm, K. [Johanniter Hospital Bonn (Germany). Dept. of Radiology

    2015-07-15

    To analyze the outcome of patients undergoing percutaneous CT-guided radiofrequency ablation (RFA) of small renal masses (SRM) at a single center during a ten-year time period. Patient records of renal RFAs (07/2003 - 11/2013) were reviewed. Indications were SRM suspicious of malignancy on imaging and one of the following: severe comorbidity; old age; solitary kidney; impaired renal function; patient wish. Biopsy was performed at the time of RFA. Patients were excluded if no follow-up was available. Patient and procedural characteristics were recorded. Survival rates were calculated using the Kaplan-Meier's method and compared with log-rank or cox tests. 38 patients (16 females, mean age 70.0 years [range 52 - 87]) presenting with a solitary SRM were included in the study. Biopsy showed malignancy in 29 patients; 9 had benign tumors. 26 patients suffered from cardiovascular, respiratory or hepatic comorbidities. Technical success (complete ablation on first follow-up) was achieved in 95 % of cases. Two major complications (bowel perforation; hematothorax) occurred. The 3- and 7-year overall survival (OS) [any cause] rates were 73.4 ± 0.8 % and 50.3 ± 1.0 %, respectively (mean follow-up 54.6 months, range 1 - 127). 4 recurrences and 2 metastases were observed. The presence of comorbidities was the only independent predictor of OS. There was no difference in survival between patients with benign and malignant tumors. RFA of SRM is successful in a large percentage of cases with a low complication rate and durable local control. As RFA is typically performed in multimorbid patients, overall survival seems to depend primarily on comorbidities rather than cancer progression.

  20. Study of CT-guided iodine-125 implantation in the treatment of rabbit VX2 tumor

    International Nuclear Information System (INIS)

    He Kewu; Gao Bin; Li Jiajia

    2008-01-01

    Objective: To evaluate the effect of CT-guided iodine-125 seed( 125 I) implantation to rabbit model VX2 tumor cell apoptosis. Methods: VX2 tumor cells were implanted into muscle of 40 rabbits legs, 3 weeks later, as the diameter of tumor reached 2 cm available for test. Randomly selected the sampling tumor on one leg of rabbit as for the test team and tumor on the contralateral leg as for control team. Under CT guidance, 125 I seeds were implanted into 20 tumor lesions of the test team, and hollow seeds were implanted into 20 tumor lesions of the control team. Instantly, 72 h, 1, 2, 3 w after operation, percutaneous tumor tissue sampling was done 0.5-1.0 cm and 1.0-1.5 cm away from seed implanted site under CT guidance; and apoptosis was investigated by FCM. Results: Instantly, 72 h, 1, 2, 3 w after treatment with iodine-125 ( 125 I) implantation, the tissue sampling away from seed 0.5-1.0 cm showed the apoptosis rates of control team and test team were respectively as follows: (5.43±0.67)% and (5.48±0.66)%, (P>0.05), (5.45±0.58)% and (11.60±0.87)%, (P O.05)of the control team and test team. Conclusions: 125 I seeds implantation can induce tumor cell apoptosis, beginning at 72 h and reached peak at 2 w and kept the high level here afterword. The apoptosis rate descended rapidly along with the increase of distance away from the 125 I seedling. (authors)

  1. MRI study for CT-guided stereotactic aspiration of intracerebral hematoma

    International Nuclear Information System (INIS)

    Takahashi, Toshie; Okada, Hitoshi; Kaneko, Uichi; Nishino, Akiko; Ueno, Shinji; Owada, Yuji.

    1994-01-01

    Twenty-five patients with acute hypertensive intracerebral hematomas, diagnosed by computed tomography (CT), underwent CT-guided stereotactic aspiration. Magnetic resonance (MR) images were obtained immediately before aspiration, using T 1 -weighted (TR=500 msec, TE=15 msec) and T 2 -weighted (TR=2500 msec, TE=120 msec) sequences and a 0.5 Tesla MR system. On the basis of the MR images the hematomas were divided into peripheral, central, and core segments. The signal intensities were divided into seven grades based on the comparison with white matter. The sequential changes in each segment on the MR images were evaluated, and the ratio of hematoma removal vs. size of residual hematoma was assessed by preoperative MR imaging and pre-and post-operative CT. The hematomas were located in the putamen in 13 cases, the thalamus in 8, combined in 2, and subcortex in 2. The hematomas, targeted in their centers, were evacuated by the aspiration procedure alone, 1 to 12 days after onset (day 0=day of onset). The results were as follows : 1) The proportion of hematomas removed was high after day 4. 2) Sequential T 1 -weighted images showed that the peripheral segments gradually increased in signal intensity, appearing as high-intensity rings that gradually filled and could be easily aspirated. 3) In those cases in which sequential T 2 -weighted images showed the central segments gradually increasing in signal intensity, the hematomas were easily aspirated if the signal was either iso-intense or hyper-intense. 4) Several hematomas had a core that appeared as a high intensity signal on T1-weighted images and as a low intensity signal on T 2 -weighted images; these hematomas could not be aspirated. (author)

  2. Initial experience of Fag-PET/CT guided Imr of head-and-neck carcinoma

    International Nuclear Information System (INIS)

    Wang Dian; Schultz, Christopher J.; Jursinic, Paul A.; Bialkowski, Mirek; Zhu, X. Ronald; Brown, W. Douglas; Rand, Scott D.; Michel, Michelle A.; Campbell, Bruce H.; Wong, Stuart; Li, X. Allen; Wilson, J. Frank

    2006-01-01

    Purpose: The purpose of this study is to evaluate the impact of 18 F-fluorodeoxyglucose positron emission tomography (Fag-PET) fused with planning computed tomography (CT) on tumor localization, which guided intensity-modulated radiotherapy (Imr) of patients with head-and-neck carcinoma. Methods and Materials: From October 2002 through April 2005, we performed Fag-PET/CT guided Imr for 28 patients with head-and-neck carcinoma. Patients were immobilized with face masks that were attached with five fiducial markers. Fag-PET and planning CT scans were performed on the same flattop table in one session and were then fused. Target volumes and critical organs were contoured, and Imr plans were generated based on the fused images. Results: All 28 patients had abnormal increased uptake in Fag-PET/CT scans. PET/CT resulted in CT-based staging changes in 16 of 28 (57%) patients. PET/CT fusions were successfully performed and were found to be accurate with the use of the two commercial planning systems. Volume analysis revealed that the PET/CT-based gross target volumes (GTVs) were significantly different from those contoured from the CT scans alone in 14 of 16 patients. In addition, 16 of 28 patients who were followed for more than 6 months did not have any evidence of locoregional recurrence in the median time of 17 months. Conclusion: Fused images were found to be useful to delineate GTV required in IMRT planning. PET/CT should be considered for both initial staging and treatment planning in patients with head-and-neck carcinoma

  3. CT-guided radiofrequency ablation of osteoid osteoma using a novel battery-powered drill

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Collettini, Federico; Hamm, Bernd; Gebauer, Bernhard [Charite Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Joehrens, Korinna [Charite Universitaetsmedizin Berlin, Department of Pathology, Berlin (Germany)

    2015-05-01

    To evaluate the use of a novel battery-powered drill, enabling specimen requirement while drilling, in radiofrequency ablation of osteoid osteoma as an alternative to conventional orthopedic drills. Between 2009 and 2013, altogether 33 patients underwent CT-guided radiofrequency ablation of an osteoid osteoma at our institution. To access the nidus of the clinically and radiologically suspected osteoid osteoma, a channel was drilled using the OnControl Bone Marrow Biopsy System (OBM, Arrow OnControl, Teleflex, Shavano Park, TX, USA) and a biopsy was taken. Procedure time (i.e., drilling including local anesthesia), amount of scans (i.e., single-shot fluoroscopy), radiation exposure, and the results of biopsy were investigated and compared retrospectively to a classical approach using either a manual bone biopsy system or a conventional orthopedic drill (n = 10) after ethical review board approval. Drilling the tract into the nidus was performed without problems in 22 of the 23 OBM cases. Median procedure time was 7 min compared to 13 min using the classical approach (p < 0.001). Median amount CT scans, performed to control correct positioning of the drill was comparable with 26 compared to 24.5 (p = NS) scans. Histologically, the diagnosis of osteoid osteomas could be determined in all 17 cases where a biopsy was taken. Radiofrequency ablation could be performed without problems in any case. The use of the battery-powered drill was feasible and facilitated the access to the osteoid osteoma's nidus offering the possibility to extract a specimen in the same step. (orig.)

  4. Major complications of high-energy microwave ablation for percutaneous CT-guided treatment of lung malignancies: single-centre experience after 4 years

    International Nuclear Information System (INIS)

    Splatt, Alexander M.; Steinke, Karin

    2015-01-01

    To evaluate the rate of major complications related to percutaneous computed tomography (CT)-guided microwave ablation (MWA) of primary and secondary lung malignancies performed at our institution over a 4-year period. From May 2010 to September 2014, 70 MWAs were performed on 51 patients. All major intra- and post-procedural complications (as defined by the classification proposed by the Society of Interventional Radiology) were retrospectively analysed. The results were correlated with a systematic review of the available literature on MWA in the lung. Major complications were encountered in 14 out of 70 ablations (20%). Twenty-one separate major complications were encountered (some ablations lead to more than one major complication). One death occurred within 30 days of ablation, though the relationship to the procedure remains uncertain. Other major complications included: nine pneumothoraces requiring drain insertion (12.9%), four cases of large effusion requiring drainage (5.7%), two cases of significant pulmonary haemorrhage altering clinical management (2.9%), two infections (2.9%), one case of mechanical failure (1.4%), one chest wall burn (1.4%) and one case of pleural seeding (1.4%). Major complications were much more likely to occur if the nodule was located within 7 mm from the pleura. MWA of pulmonary tumours carries moderate risk; nevertheless, the usually manageable complications should not deter from undertaking a potentially curative therapy for poor surgical candidates.

  5. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  6. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  7. Renal Sympathetic Denervation by CT-Guided Ethanol Injection: A Phase II Pilot Trial of a Novel Technique

    International Nuclear Information System (INIS)

    Ricke, J.; Seidensticker, M.; Becker, S.; Schiefer, J.; Adamchic, I.; Lohfink, K.; Kandulski, M.; Heller, A.; Mertens, P. R.

    2016-01-01

    ObjectivesCT-guided ethanol-mediated renal sympathetic denervation in treatment of therapy-resistant hypertension was performed to assess patient safety and collect preliminary data on treatment efficacy.Materials and MethodsEleven patients with therapy-resistant hypertension (blood pressure of >160 mmHg despite three different antihypertensive drugs including a diuretic) and following screening for secondary causes were enrolled in a phase II single arm open label pilot trial of CT-guided neurolysis of sympathetic renal innervation. Primary endpoint was safety, and secondary endpoint was a decrease of the mean office as well as 24-h systolic blood pressure in follow-up. Follow-up visits at 4 weeks, 3, and 6 months included 24-h blood pressure assessments, office blood pressure, laboratory values, as well as full clinical and quality of life assessments.ResultsNo toxicities ≥3° occurred. Three patients exhibited worsened kidney function in follow-up analyses. When accounting all patients, office systolic blood pressure decreased significantly at all follow-up visits (maximal mean decrease −41.2 mmHg at 3 months). The mean 24-h systolic blood pressure values decreased significantly at 3 months, but not at 6 months (mean: −9.7 and −6.3 mmHg, respectively). Exclusion of five patients who had failed catheter-based endovascular denervation and/or were incompliant for antihypertensive drug intake revealed a more pronounced decrease of 24-h systolic blood pressure (mean: −18.3 and −15.2 mmHg at 3 and 6 months, p = 0.03 and 0.06).ConclusionCT-guided sympathetic denervation proved to be safe and applicable under various anatomical conditions with more renal arteries and such of small diameter

  8. Renal Sympathetic Denervation by CT-Guided Ethanol Injection: A Phase II Pilot Trial of a Novel Technique

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J., E-mail: jens.ricke@med.ovgu.de; Seidensticker, M.; Becker, S. [Otto-von-Guericke University Magdeburg, Department of Radiology and Nuclear Medicine, Universitätsklinikum Magdeburg AöR (Germany); Schiefer, J. [Universitätsklinikum Magdeburg AöR, Department of Nephrology and Hypertension, Diabetes and Endocrinology (Germany); Adamchic, I.; Lohfink, K. [Otto-von-Guericke University Magdeburg, Department of Radiology and Nuclear Medicine, Universitätsklinikum Magdeburg AöR (Germany); Kandulski, M.; Heller, A.; Mertens, P. R. [Universitätsklinikum Magdeburg AöR, Department of Nephrology and Hypertension, Diabetes and Endocrinology (Germany)

    2016-02-15

    ObjectivesCT-guided ethanol-mediated renal sympathetic denervation in treatment of therapy-resistant hypertension was performed to assess patient safety and collect preliminary data on treatment efficacy.Materials and MethodsEleven patients with therapy-resistant hypertension (blood pressure of >160 mmHg despite three different antihypertensive drugs including a diuretic) and following screening for secondary causes were enrolled in a phase II single arm open label pilot trial of CT-guided neurolysis of sympathetic renal innervation. Primary endpoint was safety, and secondary endpoint was a decrease of the mean office as well as 24-h systolic blood pressure in follow-up. Follow-up visits at 4 weeks, 3, and 6 months included 24-h blood pressure assessments, office blood pressure, laboratory values, as well as full clinical and quality of life assessments.ResultsNo toxicities ≥3° occurred. Three patients exhibited worsened kidney function in follow-up analyses. When accounting all patients, office systolic blood pressure decreased significantly at all follow-up visits (maximal mean decrease −41.2 mmHg at 3 months). The mean 24-h systolic blood pressure values decreased significantly at 3 months, but not at 6 months (mean: −9.7 and −6.3 mmHg, respectively). Exclusion of five patients who had failed catheter-based endovascular denervation and/or were incompliant for antihypertensive drug intake revealed a more pronounced decrease of 24-h systolic blood pressure (mean: −18.3 and −15.2 mmHg at 3 and 6 months, p = 0.03 and 0.06).ConclusionCT-guided sympathetic denervation proved to be safe and applicable under various anatomical conditions with more renal arteries and such of small diameter.

  9. In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

    International Nuclear Information System (INIS)

    Huh, Young June; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16 degree, 0.57±0.15 degree, respectively. However, for the two different angulations in each group, the 20 degree angulation showed a greater error in the deviation of the entry point than did the 10 degree angulation. The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

  10. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  11. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  12. A simplified CT-guided approach for greater occipital nerve infiltration in the management of occipital neuralgia.

    Science.gov (United States)

    Kastler, Adrian; Onana, Yannick; Comte, Alexandre; Attyé, Arnaud; Lajoie, Jean-Louis; Kastler, Bruno

    2015-08-01

    To evaluate the efficacy of a simplified CT-guided greater occipital nerve (GON) infiltration approach in the management of occipital neuralgia (ON). Local IRB approval was obtained and written informed consent was waived. Thirty three patients suffering from severe refractory ON who underwent a total of 37 CT-guided GON infiltrations were included between 2012 and 2014. GON infiltration was performed at the first bend of the GON, between the inferior obliqus capitis and semispinalis capitis muscles with local anaesthetics and cortivazol. Pain was evaluated via VAS scores. Clinical success was defined by pain relief greater than or equal to 50 % lasting for at least 3 months. The pre-procedure mean pain score was 8/10. Patients suffered from left GON neuralgia in 13 cases, right GON neuralgia in 16 cases and bilateral GON neuralgia in 4 cases. The clinical success rate was 86 %. In case of clinical success, the mean pain relief duration following the procedure was 9.16 months. Simplified CT-guided infiltration appears to be effective in managing refractory ON. With this technique, infiltration of the GON appears to be faster, technically easier and, therefore, safer compared with other previously described techniques. • Occipital neuralgia is a very painful and debilitating condition • GON infiltrations have been successful in the treatment of occipital neuralgia • This simplified technique presents a high efficacy rate with long-lasting pain relief • This infiltration technique does not require contrast media injection for pre-planning • GON infiltration at the first bend appears easier and safer.

  13. Cost-effectiveness analysis of PET-CT-guided management for locally advanced head and neck cancer.

    Science.gov (United States)

    Smith, A F; Hall, P S; Hulme, C T; Dunn, J A; McConkey, C C; Rahman, J K; McCabe, C; Mehanna, H

    2017-11-01

    A recent large United Kingdom (UK) clinical trial demonstrated that positron-emission tomography-computed tomography (PET-CT)-guided administration of neck dissection (ND) in patients with advanced head and neck cancer after primary chemo-radiotherapy treatment produces similar survival outcomes to planned ND (standard care) and is cost-effective over a short-term horizon. Further assessment of long-term outcomes is required to inform a robust adoption decision. Here we present results of a lifetime cost-effectiveness analysis of PET-CT-guided management from a UK secondary care perspective. Initial 6-month cost and health outcomes were derived from trial data; subsequent incidence of recurrence and mortality was simulated using a de novo Markov model. Health benefit was measured in quality-adjusted life years (QALYs) and costs reported in 2015 British pounds. Model parameters were derived from trial data and published literature. Sensitivity analyses were conducted to assess the impact of uncertainty and broader National Health Service (NHS) and personal social services (PSS) costs on the results. PET-CT management produced an average per-person lifetime cost saving of £1485 and an additional 0.13 QALYs. At a £20,000 willingness-to-pay per additional QALY threshold, there was a 75% probability that PET-CT was cost-effective, and the results remained cost-effective over the majority of sensitivity analyses. When adopting a broader NHS and PSS perspective, PET-CT management produced an average saving of £700 and had an 81% probability of being cost-effective. This analysis indicates that PET-CT-guided management is cost-effective in the long-term and supports the case for wide-scale adoption. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    International Nuclear Information System (INIS)

    Fukuda, Hozumi; Ibukuro, Kenji; Tsukiyama, Toshitaka; Ishii, Rei

    2004-01-01

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which were therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis

  15. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    International Nuclear Information System (INIS)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo

    2012-01-01

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  16. Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Kagel, Thomas; Nicolas, Volkmar [Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Bochum (Germany); Mueller, Klaus-Michael [Ruhr-University of Bochum, Institute of Pathology, BG Clinics Bergmannsheil, Bochum (Germany); Nuesslein, Thomas G.; Rieger, Christian H.L. [Ruhr-University of Bochum, Pediatric Hospital, Bochum (Germany)

    2005-07-01

    Children with chronic infectious interstitial lung disease often have to undergo open lung biopsy to establish a final diagnosis. Open lung biopsy is an invasive procedure with major potential complications. Transthoracic lung biopsy (TLB) guided by computed tomography (CT) is a less-invasive well-established procedure in adults. Detailing the role of low-dose CT-guided TLB in the enhanced diagnosis of chronic lung diseases related to infection in children. A group of 11 children (age 8 months to 16 years) underwent CT-guided TLB with a 20-gauge biopsy device. All investigations were done under general anaesthesia on a multidetector CT scanner (SOMATOM Volume Zoom, Siemens, Erlangen, Germany) using a low-dose protocol (single slices, 120 kV, 20 mAs). Specimens were processed by histopathological, bacteriological, and virological techniques. All biopsies were performed without major complications; one child developed a small pneumothorax that resolved spontaneously. A diagnosis could be obtained in 10 of the 11 patients. Biopsy specimens revealed chronic interstitial alveolitis in ten patients. In five patients Chlamydia pneumoniae PCR was positive, in three Mycoplasma pneumoniae PCR was positive, and in two Cytomegalovirus PCR was positive. The average effective dose was 0.83 mSv. Low-dose CT-guided TLB can be a helpful tool in investigating chronic infectious inflammatory processes in children with minimal radiation exposure. It should be considered prior to any open surgical procedure performed for biopsy alone. In our patient group no significant complication occurred. A disadvantage of the method is that it does not allow smaller airways and vessels to be assessed. (orig.)

  17. Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

    International Nuclear Information System (INIS)

    Sarma, Asha; Shyn, Paul B.; Vivian, Mark A.; Ng, Ju-Mei; Tuncali, Kemal; Lorch, Jorchen H.; Zaheer, Sarah N.; Gordon, Michael S.; Silverman, Stuart G.

    2015-01-01

    Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements

  18. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor.

    Science.gov (United States)

    Panizza, Pedro Sergio Brito; de Albuquerque Cavalcanti, Conrado Furtado; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; de Menezes, Marcos Roberto

    2016-02-01

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  19. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    International Nuclear Information System (INIS)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; Menezes, Marcos Roberto de

    2016-01-01

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones

  20. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil); Yamaguchi, Nise Hitomi [Instituto Avanços em Medicina (Brazil); Leite, Claudia Costa; Cerri, Giovanni Guido; Menezes, Marcos Roberto de, E-mail: marcos.menezes@hc.fm.usp.br [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil)

    2016-02-15

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  1. Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, Asha, E-mail: ashasarma@gmail.com; Shyn, Paul B., E-mail: pshyn@partners.org [Brigham and Women’s Hospital, Department of Radiology (United States); Vivian, Mark A. [University of Manitoba, Department of Radiology (Canada); Ng, Ju-Mei [Brigham and Women’s Hospital, Department of Anesthesiology (United States); Tuncali, Kemal [Brigham and Women’s Hospital, Department of Radiology (United States); Lorch, Jorchen H. [Dana Farber Cancer Institute, Department of Medicine (United States); Zaheer, Sarah N.; Gordon, Michael S. [Brigham and Women’s Hospital, Department of Endocrinology (United States); Silverman, Stuart G. [Brigham and Women’s Hospital, Department of Radiology (United States)

    2015-10-15

    Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements.

  2. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  3. Compared to controls, patients with ruptured aneurysm and surgical intervention show increase in symptoms of depression and lower cognitive performance, but their objective sleep is not affected.

    Science.gov (United States)

    Brand, Serge; Zimmerer, Stefan; Kalak, Nadeem; Planta, Sandra Von; Schwenzer-Zimmerer, Katja; Müller, Andreas Albert; Zeilhofer, Hans-Florian; Holsboer-Trachsler, Edith

    2015-02-01

    Patients with aneurysmal subarachnoid haemorrhage (aSAH) have impaired sleep and cognitive performance together with more difficulties in social and everyday life. Hypocortisolism has also been reported. However, a study assessing all dimensions between aSAH severity, objective and subjective sleep, cortisol secretion, cognitive performance and social and everyday life has not so far been performed. The aim of the present study was therefore two-fold: (1) to assess, in a sample of patients with aSAH, objective and subjective sleep, cognitive functioning, social skills and cortisol secretion concurrently, and (2) to compare patients on these variables with a control group. Twenty-one patients (17 females; mean age: 58.80 years) with ruptured aneurysm and surgical intervention and 21 (14 females; mean age: 58.90 years) age- and gender-matched controls took part in the study. Assessments covered objective sleep-EGG recordings, subjective sleep, salivary cortisol analysis, and psychological functioning including memory performance, mood, and emotion recognition. Compared to healthy controls, patients had lower scores for verbal memory performance and emotion recognition; they also reported more marked depressive symptoms and complained of poor sleep. However, no differences were found for objective sleep or cortisol secretion. Subjective and objective sleep, cortisol secretion and psychological functioning were unrelated. Findings indicate that patients with aSAH face psychological rather than physiological issues.

  4. CT-guided screw fixation of vertical sacral fractures in local anaesthesia using a standard CT; CT-kontrollierte Schraubenosteosynthese von vertikalen Frakturen des hinteren Beckenringes in Lokalanaesthesie

    Energy Technology Data Exchange (ETDEWEB)

    Reuther, G.; Dehne, I. [Thueringen-Klinik, Saalfeld (Germany). Radiologische Klinik; Roehner, U.; Will, T.; Petereit, U. [Thueringen-Klinik, Saalfeld (Germany). Orthopaedics and Trauma Surgery

    2014-12-15

    To evaluate time efficiency, radiation dose, precision and complications of percutaneous iliosacral screw placement under CT-guidance in local anaesthesia. Retrospective analysis of 143 interventions in 135 patients during a period of 42 months. Implant failures could be evaluated in 85/182 screws and bony healing or refracturing in 46/182 screws. A total of 182 iliosacral screw placements in 179 vertical sacral fractures (105 unilateral, 37 bilateral) took place in 135 patients. 166/179 of the sacral fractures were detected in Denis zone 1, 10 in Denis zone 2 and 3 in Denis zone 3. No screw misplacements including the simultaneous bilateral procedures were noted. The average time for a unilateral screw placement was 23 minutes (range: 14-52 minutes) and 35 minutes (range: 21-60 minutes) for simultaneous bilateral screwing. The dose length product was 365 mGy x cm (range: 162-1014 mGy x cm) for the unilateral and 470 mGy x cm (range: 270-1271 mGy x cm) for the bilateral procedure. 1 gluteal bleeding occurred as the only acute minor complication (0.7%). Fracture healing was verified with follow-up CTs in 42/46 sacral fractures after screw placement. Backing out occurred in 12/85 screws between 6 and 69 days after intervention. In 8 patients contralateral stress fractures were detected after unilateral screw placement between day 10 and 127 (average: 48 days). CT-guided iliosacral screw placement in sacral fractures is a safe tool providing a very high precision. The radiation dose is in the order of a diagnostic CT of the pelvis for both unilateral and bilateral screws. Contralateral stress fractures in unilateral screw placements have to be considered during the first weeks after intervention.

  5. CT-guided localization of small pulmonary nodules using adjacent microcoil implantation prior to video-assisted thoracoscopic surgical resection

    Energy Technology Data Exchange (ETDEWEB)

    Su, Tian-Hao; Jin, Long; He, Wen [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Fan, Yue-Feng [Xiamen University, Department of Interventional Therapy, The First Affiliated Hospital, Xiamen, Fujian (China); Hu, Li-Bao [Peking University People' s Hospital, Department of Radiology, Beijing (China)

    2015-09-15

    To describe and assess the localization of small peripheral pulmonary nodules prior to video-assisted thoracoscopic surgical (VATS) resection using the implantation of microcoils. Ninety-two patients with 101 pulmonary nodules underwent computed tomography (CT)-guided implantation of microcoils proximal to each nodule. Patients were randomly assigned to undergo entire microcoil or leaving-microcoil-end implantations. The complications and efficacy of the two implantation methods were evaluated. VATS resection of lung tissue containing each pulmonary lesion and microcoil were performed in the direction of the microcoil marker. Histopathological analysis was performed for the resected pulmonary lesions. CT-guided microcoil implantation was successful in 99/101 cases, and the placement of microcoils within 1 cm of the nodules was not disruptive. There was no difference in the complications and efficacy associated with the entire implantation method (performed for 51/99 nodules) versus the leaving-microcoil-end implantation method (performed for 48/99 nodules). All nodules were successfully removed using VATS resection. Asymptomatic pneumothorax occurred in 16 patients and mild pulmonary haemorrhage occurred in nine patients. However, none of these patients required further surgical treatment. Preoperative localization of small pulmonary nodules using a refined percutaneous microcoil implantation method was found to be safe and useful prior to VATS resection. (orig.)

  6. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  7. CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

    International Nuclear Information System (INIS)

    Kelogrigoris, M.; Sotiropoulou, E.; Stathopoulos, K.; Georgiadou, V.; Philippousis, P.; Thanos, L.

    2011-01-01

    This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26–52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

  8. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  9. CT-guided percutaneous gastrostomy: success rate, early and late complications; CT-gesteuerte perkutane Gastrostomie: Technischer Erfolg, Frueh- und Spaetkomplikationen

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk, A.; Voelk, M. [Radiologie, Bundeswehrkrankenhaus Ulm (Germany); Strotzer, M. [Radiologie, Klinikum Hohe Warte (Germany); Feuerbach, S.; Rogler, G. [Radiologie, Klinikum der Universitaet Regensburg (Germany); Seitz, J. [Radiologie, MVZ Dr. Neumaier und Kollegen (Germany)

    2007-04-15

    Purpose: Percutaneous endoscopic gastrostomy (PEG) and percutaneous radiologic gastrostomy (PRG) are the standard methods of ensuring long-term enteral food intake in patients with dysphagia caused by neoplasia or neurological disorders. High-grade obstructions of the upper digestive tract or inadequate transillumination can prevent PEG. CT-guided percutaneous gastrostomy (PG) represents a special technique for enabling gastrostomy in patients for whom the endoscopic method is impossible. The aim of this study was to evaluate the results and complications of CT-guided percutaneous gastrostomy. Materials and Methods: CT-guided PG was performed in 83 patients, mostly with malignancy of the upper respiratory or digestive tract. Medical records for these patients were reviewed, and the results and complications of the CT-guided PG were analyzed retrospectively. Complications were grouped into four categories: Major and minor complications as well as early and late complications. Results: In 95.2 % of all cases (79/83), CT-guided PG was successful in the first attempt. Within the first 3 days, 5 major complications including 4 tube dislocations and one case of peritonitis were found in 4/79 patients (5.1 %). One of these patients experienced two early major complications. Early minor complications, mainly local skin irritations and temporary stomachache, were observed in 31 patients (39.2 %). Three days after CT-guided PG, 4 cases of major complications were documented, yielding a total rate of major complications was 8.7 % (7/79). Hemorrhage requiring blood transfusion or perforation after gastrostomy was not observed. 29.1 % of the patients (23/79) experienced late minor complications. (orig.)

  10. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  11. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  12. CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

    International Nuclear Information System (INIS)

    Sommer, C. M.; Lemm, G.; Hohenstein, E.; Bellemann, N.; Stampfl, U.; Goezen, A. S.; Rassweiler, J.; Kauczor, H. U.; Radeleff, B. A.; Pereira, P. L.

    2013-01-01

    Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m 2 before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m 2 after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  13. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  14. CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Lemm, G.; Hohenstein, E. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany); Bellemann, N.; Stampfl, U. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Goezen, A. S.; Rassweiler, J. [Clinic for Urology, SLK Kliniken Heilbronn GmbH (Germany); Kauczor, H. U.; Radeleff, B. A. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Pereira, P. L. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany)

    2013-06-15

    Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 {+-} 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 {+-} 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 {+-} 13.6 min and 43.7 {+-} 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 {+-} 8.8 months, local recurrence-free survival was 14.4 {+-} 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 {+-} 16.6 ml/min/1.73 m{sup 2} before RF ablation vs. 47.2 {+-} 11.9 ml/min/1.73 m{sup 2} after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  15. PET/CT-guided treatment planning for paediatric cancer patients: a simulation study of proton and conventional photon therapy

    DEFF Research Database (Denmark)

    Kornerup, Josefine S.; Brodin, N. P.; Bjork-Eriksson, T.

    2015-01-01

    ) and estimated risk of secondary cancer (SC). RESULTS: Considerable deviations between CT- and PET/CT-guided target volumes were seen in 3 out of the 11 patients studied. However, averaging over the whole cohort, CT or PET/CT guidance introduced no significant difference in the shape or size of the target...... or decreasing irradiated volumes, suggesting that the long-term morbidity of RT in childhood would on average remain largely unaffected. ADVANCES IN KNOWLEDGE: (18)F-FDG PET-based RT planning does not systematically change NTCP or SC risk for paediatric cancer patients compared with CT only. 3 out of 11...... patients had a distinct change of target volumes when PET-guided planning was introduced. Dice and mismatch metrics are not sufficient to assess the consequences of target volume differences in the context of RT....

  16. CT guided biopsies as a part of the investigations in findings in the lung and thorax wall

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    was performed. Results: In 86 % of the biopsies, the tissue material was found sufficient. In 32 % of the biopsies there was a complication, mostly pneumothorax (30%), but in only 15 % of the 520 cases chest drainage was needed. There was one death in a known cancer patient with severe reduced lung and cardiac...... function. Patients with more than 10 cigarette pack years had a complication risk twice as high compared to patients with less pack years. We found that the risk of pneumothorax rises the further the lesion is from the skin surface, the smaller the lesions are and when the patient is biopsied in a lateral...... position. We found a higher risk of complications in females. Conclusion: CT guided biopsy is an excellent tool in the analysis of lesions in the lungs. This study clearly shows that the risk of developing a pneumothorax is significantly higher among smokers and former smokers with more than 10 pack years....

  17. Resolution of Postural Orthostatic Tachycardia Syndrome After CT-Guided, Percutaneous T2 Ethanol Ablation for Hyperhidrosis

    Energy Technology Data Exchange (ETDEWEB)

    Brock, Malcolm, E-mail: mabrock@jhmni.edu [Johns Hopkins University, Department of Thoracic Surgery, Center for Sweat Disorders (United States); Chung, Tae Hwan, E-mail: Tchang7@jhmi.edu [Johns Hopkins University, Physical Medicine and Rehabilitation (United States); Gaddam, Sathvika Reddy, E-mail: drsathvikareddy@yahoo.com; Kathait, Anjaneya Singh, E-mail: askathait@gmail.com [Johns Hopkins University, Vascular & Interventional Radiology (United States); Ober, Cecily, E-mail: ceober21@gmail.com [Johns Hopkins University, Department of Thoracic Surgery (United States); Georgiades, Christos, E-mail: cgeorgi@jhmi.edu [Johns Hopkins University, Vascular & Interventional Radiology (United States)

    2016-12-15

    Postural orthostatic tachycardia syndrome is characterized by orthostatic intolerance. Orthostasis (or other mild physical stress) triggers a cascade of inappropriate tachycardia, lightheadedness, palpitations, and often fainting. The underlying defect is sympathetic dysregulation of the heart, which receives its sympathetic tone from the cervical and upper thoracic sympathetic ganglia. Primary hyperhidrosis is also thought to be the result of sympathetic dysregulation. We present the case of a patient treated with CT-guided, percutaneous T2 EtOH sympatholysis for craniofacial hyperhidrosis. The patient also suffered from postural orthostatic tachycardia syndrome for many years and was unresponsive to treatment. Immediately after sympatholysis, the patient experienced resolution of both craniofacial hyperhidrosis and postural orthostatic tachycardia syndrome.

  18. The prevention and treatment of biliary complications occurred after CT-guided percutaneous radiofrequency ablation for hepatic neoplasms

    International Nuclear Information System (INIS)

    Li Jianjun; Zheng Jiasheng; Cui Xiongwei; Cui Shichang; Sun Bin

    2011-01-01

    Objective: To discuss the prevention and treatment of biliary complications occurred after CT-guided percutaneous radiofrequency ablation (RFA) for hepatic neoplasms. Methods: A total of 1136 patients, including 920 males and 216 females, with hepatic neoplasms were enrolled in this study. The hepatic tumors consisted of primary hepatocellular carcinoma (n=1037), hepatic metastasis (n=83) and hepatic cavernous hemangioma (n=16). The diameters of the tumors ranged from 0.5 to 16 cm. A total of 1944 RFA procedures were carried out in all patients. Results: Thirty-five patients developed biliary complication (35/1944, 1.80%). Twelve patients developed asymptomatic bile duct dilatation and no special treatment was given. Obstructive jaundice occurred in two patients and percutaneous transhepatic cholangiocholecystic drainage (PTCD) together with subsequent inner stent implantation had to be carried out. Eighteen patients developed biloma, and liver abscess formation secondary to biloma infection occurred in seven of them. Percutaneous transhepatic biloma drainage (PTBD) was adopted in all these patients. One patient suffered from obstructive jaundice complicated by biloma, and both PTCD and PTBD combined with inner stent implantation were simultaneously performed. One patient had the biloma secondary to obstructive jaundice, and PTCD followed by PTBD was conducted in turn. One patient developed obstructive jaundice secondary to biloma, and PTBD followed by PTCD was employed in turn. Conclusion: Obstructive jaundice and biloma are severe biliary complications occurred after CT-guided percutaneous radiofrequency ablation for hepatic tumors, and PTCD and/or PTBD should be carried out without delay to treat these complications. The clinical symptoms can be relieved, or even completely disappear, after treatment. (authors)

  19. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  20. Application of Intraoperative CT-Guided Navigation in Simultaneous Minimally Invasive Anterior and Posterior Surgery for Infectious Spondylitis

    Directory of Open Access Journals (Sweden)

    Meng-Huang Wu

    2017-01-01

    Full Text Available This study was aimed at evaluating the safety and efficacy of using intraoperative computed tomography- (iCT- guided navigation in simultaneous minimally invasive anterior and posterior surgery for infectious spondylitis. Nine patients with infectious spondylitis were enrolled in this study. The average operative time was 327.6 min (range, 210–490 and intraoperative blood loss was 407 cc (range, 50–1,200. The average duration of hospital stay was 48.9 days (range, 11–76. Out of a total of 54 pedicle screws employed, 53 screws (98.1% were placed accurately. A reduced visual analog scale on back pain (from 8.2 to 2.2 and Oswestry disability index (from 67.1% to 25.6% were found at the 2-year follow-up. All patients had achieved resolution of spinal infection with reduced average erythrocyte sedimentation rate (from 83.9 to 14.1 mm/hr and average C-reactive protein (from 54.4 to 4.8 mg/dL. Average kyphotic angle correction was 10.5° (range, 8.4°–12.6° postoperatively and 8.5° (range, 6.9°–10.1° after 2 years. In conclusion, the current iCT-guided navigation approach has been demonstrated to be an alternative method during simultaneous minimally invasive anterior and posterior surgery for infectious spondylitis. It can provide a good intraoperative orientation and visualization of anatomic structures and also a high pedicle screw placement accuracy in patient’s lateral decubitus position.

  1. Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm. A single-institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ying-Yueh [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); Chen, Chun-Ku [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China); National Yang-Ming University, Institute of Clinical Medicine, Taipei (China); Yeh, Yi-Chen [National Yang-Ming University, School of Medicine, Taipei (China); Taipei Veterans General Hospital, Department of Pathology and Laboratory Medicine, Taipei (China); Wu, Mei-Han [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China)

    2018-02-15

    This retrospective study evaluated the diagnostic yield and safety of CT-guided core biopsy of pulmonary nodules ≤8 mm. We determined the diagnostic yield and safety profile of CT-guided lung biopsies for 125 pulmonary nodules ≤8 mm. Pathological diagnoses were made by a combination of histopathological examination and imprint cytology. Results were compared with biopsy results for 134 pulmonary nodules >8 and ≤10 mm. Final diagnoses were established in 94 nodules ≤8 mm. The sensitivity, specificity and diagnostic accuracy of CT-guided core biopsy for nodules ≤8 mm were 87.1 % (61/70 nodules), 100 % (24/24) and 90.4 % (85/94), respectively. Diagnostic failure rates were comparable for nodules ≤8 mm and nodules >8 mm and ≤10 mm (9/94, 9.6 % and 7/111, 6.3 %, respectively, P=0.385). The rate of tube thoracostomy for nodules ≤8 mm was comparable to that for nodules >8 and ≤10 mm (1.6 % vs. 0.7 %, P=0.611). Nodules ≤6 mm had a higher non-diagnostic result rate of 15.4 % (6/39) than did nodules >8 and ≤10 mm (3.7 %, 5/134, P=0.017). CT-guided pulmonary biopsy is feasible for lung nodules ≤8 mm, especially those >6 mm, and has an acceptable diagnostic yield and safety profile. (orig.)

  2. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  3. Unresectable colorectal liver metastases. Percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT); Nicht resektable kolorektale Lebermetastasen. Perkutane Ablation mittels CT-gesteuerter Hochdosisbrachytherapie (CT-HDBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Lutter, A.; Schnapauff, D.; Denecke, T.; Gebauer, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Hildebrandt, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Oncology; Puhl, G. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of General, Visceral and Transplantation Surgery; Wust, P. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiation Oncology

    2014-06-15

    Purpose: To evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) of unresectable colorectal liver metastases (CRLMs). Materials and Methods: Retrospective analysis of all consecutive patients with unresectable CRLMs treated with CT-HDRBT between January 2008 and November 2012. Treatment was performed by CT-guided catheter placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed after 6 weeks and then every 3 months post-intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: 80 heavily pretreated patients with 179 metastases were available for MRI evaluation for a mean follow-up time of 16.9 months. The mean tumor diameter was 28.5 mm (range: 8 - 107 mm). No major complications were observed. A total of 23 (12.9%) local tumor progressions were observed. Lesions ≥ 4 cm in diameter showed significantly more local progression than smaller lesions (< 4 cm). 50 patients (62.5%) experienced systemic tumor progression. The median TTP was 6 months. 28 (43%) patients died during the follow-up period. The median OS after ablation was 18 months. Conclusion: CT-HDRBT is an effective technique for the treatment of unresectable CRLMs and warrants promising LTC rates compared to thermal ablative techniques. A combination with other local and systemic therapies should be evaluated in patients with lesions > 4 cm in diameter, in which higher progression rates are expected. (orig.)

  4. CT-guided percutaneous neurolysis methods. State of the art and first results; CT-gesteuerte Neurolysen. Stand der Technik und aktuelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Richter, G.M. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Roeren, T. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-09-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [Deutsch] Thorakale und lumbale Sympathikolyse sowie die Zoeliakusblockade

  5. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  6. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  7. Ruptured gastroepiploic artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Ahmad S. Ashrafi

    Full Text Available Introduction: Gastroepiploic artery aneurysms are extremely rare, with few reported cases in the literature. The risk of rupture however, is high and thus warrants attention. Presentation of case: Here we present a rare case of a women who presented to the emergency department in shock and was found to have a ruptured gastroepiploic artery aneurysm during surgical exploration. Suture ligation of the aneurysm was completed. Discussion: Although rare, gastroepiploic artery aneurysms have up to a 90% rate of rupture and therefore require intervention. A laparoscopic approach has been described however, in cases where rupture has occurred, urgent laparotomy and control of hemorrhage is needed. Conclusion: We describe a rare case of a ruptured gastroepiploic aneurysm that was successfully managed with urgent laparotomy and aneurysmal resection. Keywords: Gastroepiploic, Aneurysm, Hemorrhage, Case report

  8. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  9. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  10. CT-guided radiofrequency ablation of T1a renal cell carcinma in Korea; Mid-erm outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.

  11. CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of)

    2016-11-01

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.

  12. CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes

    International Nuclear Information System (INIS)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo

    2016-01-01

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m 2 (14.2–142.7 mL/min/1.73 m 2 ) and 72.0 mL/min/1.73 m 2 (7.2–112.6 mL/min/1.73 m 2 ), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes

  13. CT-Guided Lumbar Sympathectomy: Results and Analysis of Factors Influencing the Outcome

    International Nuclear Information System (INIS)

    Heindel, Walter; Ernst, Stefan; Manshausen, Gudrun; Gawenda, Michael; Siemens, Peter; Krahe, Thomas; Walter, Michael; Lackner, Klaus

    1998-01-01

    Purpose: To prospectively analyze the effectiveness of computed tomography-guided percutaneous lumbar sympathectomy (CTLS) in patients with peripheral arterial occlusive disease in relation to angiographic findings and vascular risk factors. Methods: Eighty-three patients were treated by CTLS. After clinical evaluation of the risk profile and diagnostic intraarterial digital subtraction arteriography, 14 patients underwent unilateral, and 69 bilateral one-level treatment. Follow-up studies took place on the day following the intervention, after 3 weeks, and after 3 months. Results: A total of 152 interventions were performed in 83 patients. After 3 months, clinical examination of 54 patients (5 patients had died, 24 were lost to follow-up) revealed improvement in 46% (25/54), no change in 39% (21/54), and worsening (amputation) in 15% (8/54). There was no significant statistical correlation among any of the analyzed factors (diabetes mellitus, arterial hypertension, smoking, hyperlipidemia, obesity, hyperuricemia, number of risk factors, ankle-arm index, and angiography score) and the outcome after CTLS. Three major complications occurred: one diabetic patient developed a retroperitoneal abscess 2 weeks after CTLS, and in two other patients ureteral strictures were detected 3 months and 2 years after CTLS, respectively. Conclusion: As no predictive criteria for clinical improvement in an individual patient could be identified, CTLS, as a safe procedure, should be employed on a large scale in patients who are unsuitable for treatment by angioplasty or revascularization

  14. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  15. CT-guided interstitial brachytherapy of hepatocellular carcinoma before liver transplantation: an equivalent alternative to transarterial chemoembolization?

    International Nuclear Information System (INIS)

    Denecke, Timm; Stelter, Lars; Schnapauff, Dirk; Steffen, Ingo; Gebauer, Bernhard; Lopez Haenninen, Enrique; Wust, Peter; Sinn, Bruno; Schott, Eckart; Seidensticker, Ricarda; Puhl, Gero; Neuhaus, Peter; Seehofer, Daniel

    2015-01-01

    Transarterial chemoembolization (TACE) is established as bridging therapy of HCC listed for transplantation (LT). CT-guided brachytherapy (CTB) has not been evaluated as a bridging concept. We compared CTB and TACE for bridging before LT in HCC patients. Twelve patients with HCC received LT after CTB (minimal tumour dose, 15-20 Gy). Patients were matched (CTB:TACE, 1:2) by sex, age, number and size of lesions, and underlying liver disease with patients who received TACE before transplantation. Study endpoints were extent of necrosis at histopathology and recurrence rate after OLT. There were no significant differences between the CTB and TACE groups regarding Child-Pugh category (p = 0.732), AFP (0.765), time on waiting list (p = 0.659), number (p = 0.698) and size (p = 0.853) of HCC lesions, fulfilment of Milan-criteria (p = 0.638), or previous liver-specific treatments. CTB achieved higher tumour necrosis rates than TACE (p = 0.018). The 1- and 3-year recurrence rate in the CTB group was 10 and 10 % vs. TACE, 14 and 30 % (p = 0.292). Our data show comparable or even better response and post-LT recurrence rates of CTB compared to TACE for treating HCC in patients prior to LT. CTB should be further evaluated as an alternative bridging modality, especially for patients not suited for TACE. (orig.)

  16. CT-guided thermoplastic assisted segmentectomy is an optimal breast conserving surgery for breast cancer with nipple discharge

    International Nuclear Information System (INIS)

    Makita, Masujiro; Gomi, Naoya; Tachikawa, Tomohiro

    2004-01-01

    Improvement of imaging by injecting contrast agents into the discharging duct and immobilizing the breast mound with a drape-type thermoplastic shell in breast conserving surgery was assessed by evaluating 96 cases of breast cancer patients with nipple discharge treated by partial mastectomy between April 1998 and August 2003. These patients were divided to three groups: Group A was treated by ordinary partial mastectomy or microdochectomy without new methods. Group B underwent contrast imaging without shell immobilization, and Group C received both shell immobilization and contrast imaging. The negative rates of surgical margins in Groups A, B and C were 19.0%, 17.2%, and 37.5%, respectively. The rates of negative ''lateral'' surgical margins in Groups A, B and C were 23.8%, 27.6%, and 50%, respectively. The rate of negative ''lateral'' surgical margins in Group C was significantly higher than that in Group A. Our findings suggest CT-guided thermoplastic assisted segmentectomy, adopting both ductography CT and immobilization by shell, is an optimal breast conserving surgery for breast cancer with nipple discharge. (author)

  17. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  18. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  19. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  20. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  1. Location of pulmonary modules prior to video thoracoscopic surgery by CT-guided hook wire placement: Preliminary study

    International Nuclear Information System (INIS)

    Ferreiras, J.; Salmeron, I.; Bustos Garcia de Castro, A.; Hernando, F.; Gomez, A.; Torres, A.

    1996-01-01

    Despite the efficacy of computerized tomography (CT) or radiologically-guided percutaneous biopsy and that offluoroscopically-guided trans bronchial biopsy in characterizing pulmonary nodules, it is not always possible to determine the etiology using these techniques, making it necessary to resort to thoracotomy. Recent developments in endoscopicsurgery equipment and the availability of advance video imaging technology have extended the indications for both diagnostic and therapeutic thoracoscopy. Thus, a number of procedures that previously could only be performed bymeans of thoracotomy, such as resection of peripheral pulmonary nodules, can nowbe carried out by means of video thoracoscopic (VT) surgery. Palpation orvisual location of pulmonary nodules by thoracoscopy is essential but is not always possible when the nodules measure less than 20 mm or when their location is not subpleural. In such cases, a procedure for their prior location is useful. In eight patients with pulmonary nodules who were to undergo subsequent VT surgery, the attempt was made to locate the nodules by CT-guided placementof a hook wire, similar to that employed in breast, and methylene blue injection. The hook wire was correctly introduced without significant complications in all eight cases. The eight nodules were successfully resected during the thoracoscopic procedure, in which the hook wire and methylene blue staining were of great assistance. In certain cases, the location of pulmonary nodules by means of CT-guidehook wire placement and methylene blue injection allows the video thoracoscopic resection of lesions of difficult access. (Author)

  2. CT-guided interstitial brachytherapy of hepatocellular carcinoma before liver transplantation: an equivalent alternative to transarterial chemoembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Timm; Stelter, Lars; Schnapauff, Dirk; Steffen, Ingo; Gebauer, Bernhard; Lopez Haenninen, Enrique; Wust, Peter [Universitaetsmedizin Berlin, Klinik fuer Radiologie, Charite, Berlin (Germany); Sinn, Bruno [Charite - Universitaetsmedizin Berlin, Institut fuer Pathologie, Berlin (Germany); Schott, Eckart [Charite 2 - Universitaetsmedizin Berlin, Medizinische Klinik m.S. Hepatologie und Gastroenterologie, Berlin (Germany); Seidensticker, Ricarda [Universitaetsklinikum der Otto-v.-Gericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); Puhl, Gero; Neuhaus, Peter; Seehofer, Daniel [Charite - Universitaetsmedizin Berlin, Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Berlin (Germany)

    2015-09-15

    Transarterial chemoembolization (TACE) is established as bridging therapy of HCC listed for transplantation (LT). CT-guided brachytherapy (CTB) has not been evaluated as a bridging concept. We compared CTB and TACE for bridging before LT in HCC patients. Twelve patients with HCC received LT after CTB (minimal tumour dose, 15-20 Gy). Patients were matched (CTB:TACE, 1:2) by sex, age, number and size of lesions, and underlying liver disease with patients who received TACE before transplantation. Study endpoints were extent of necrosis at histopathology and recurrence rate after OLT. There were no significant differences between the CTB and TACE groups regarding Child-Pugh category (p = 0.732), AFP (0.765), time on waiting list (p = 0.659), number (p = 0.698) and size (p = 0.853) of HCC lesions, fulfilment of Milan-criteria (p = 0.638), or previous liver-specific treatments. CTB achieved higher tumour necrosis rates than TACE (p = 0.018). The 1- and 3-year recurrence rate in the CTB group was 10 and 10 % vs. TACE, 14 and 30 % (p = 0.292). Our data show comparable or even better response and post-LT recurrence rates of CTB compared to TACE for treating HCC in patients prior to LT. CTB should be further evaluated as an alternative bridging modality, especially for patients not suited for TACE. (orig.)

  3. Rupture of primigravid uterus and recurrent rupture

    Directory of Open Access Journals (Sweden)

    Nahreen Akhtar

    2016-08-01

    Full Text Available Uterine rupture is a deadly obstetrical emergency endangering the life of both mother and fetus. In Bangladesh, majority of deliveries arc attended by unskilled traditional birth attendant and maternal mortality is still quite high. It is rare Ln developed country but unfortunately it is common in a developing country like Bangladesh. We report a case history of a patient age 32yrs from Daudkandi, Comilla admitted with H/0 previous two rupture uterus and repair with no living issue. We did caesarean section at her 31+ weeks of pregnancy when she developed Jabour pain. A baby of 1.4 kg was delivered. During cesarean section, focal rupture was noted in previous scar of rupture. Unfortunately the baby expired in neonatal ICU after 36 hours.

  4. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  5. CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes for the treatment of intractable carcinomatous abdominal pain

    International Nuclear Information System (INIS)

    Xi Qian; Wang Peijun; Shang Mingyi; Ma Jun; Lu Ying; Huang Zongliang; Tang Junjun; Gao Xiaolong

    2010-01-01

    Objective: To evaluate CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes in treating intractable carcinomatous abdominal pain. Methods: A total of 104 patients with late stage cancers were enrolled in this study. All patients suffered from serious carcinomatous pain at upper abdomen and their retroperitoneal lymph nodes were extensively enlarged and fused, together with the involved celiac plexus, into a hard crumb. As the patients failed to respond to narcotic analgesics CT-guided ethanol nerve block therapy of celiac plexus was carried out by pushing the puncture needle through the fused lymphatic mass to celiac plexus site. The analgesic effects and complications were observed and the therapeutic results were evaluated. Results: The analgesic effective rate of ethanol nerve block therapy immediately after the procedure was 100%, and at 2 weeks, 1, 2, 3 and 4 months after the treatment it was 100%, 100%, 98.0%, 96.9% and 92.6%, respectively. No serious complications occurred during perioperative period. The living quality was markedly improved in all patients. Conclusion: For the treatment of intractable carcinomatous abdominal pain in patients with their celiac plexus being embedded in mass-like metastatic retroperitoneal lymph nodes CT-guided percutaneous ethanol nerve block therapy by pushing the puncture needle through the fused lymphatic mass to celiac plexus site is of great clinical value in relieving carcinomatous abdominal pain. (authors)

  6. Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach

    International Nuclear Information System (INIS)

    Kim, Young Kon; Kim, Chong Soo; Lee, Jeong Min; Chung, Gyung Ho; Chon, Su Bin

    2006-01-01

    Purpose: The purpose of this study was to determine the efficacy and safety of radiofrequency (RF) ablation for the treatment of hepatocellular carcinoma (HCC) in the hepatic dome with CT-guided extrathoracic transhepatic approach. Materials and methods: Fifteen patients with 15 HCCs (size range: 0.8-4 cm, mean size: 1.8 cm) in the hepatic dome were treated by RF ablation using cooled-tip electrodes and with CT-guided extrathoracic transhepatic approach. Therapeutic response of the tumor to RF ablation and procedure-related complications including hepatic injury, hemoperitoneum, and thermal injury of diaphragm were evaluated. Results: The average number of needle punctures to ensure the correct needle position in the targeted tumor was 3.7 (range: 1-6 punctures). The average ablation time was 14.7 min (range: 8-25 min). Complete necrosis without marginal recurrence after at least 13-month follow-up was attained in 13 tumors (86.7%). There were no major complications related to the procedures. Six patients had shoulder pain that lasted three days to two weeks after the procedures and their symptoms were resolved with conservative treatment. Conclusions: RF ablation using CT-guided extrathoracic transhepatic approach is an effective and safe technique for the treatment of HCC in the hepatic dome

  7. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  8. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  9. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong [Huazhong University of Science and Technology, Cancer Center, Union Hospital, Tongji Medical College, Wuhan (China)

    2017-08-15

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. (orig.)

  10. Hepatic rupture in preeclampsia

    International Nuclear Information System (INIS)

    Winer-Muram, H.T.; Muram, D.; Salazar, J.; Massie, J.D.

    1985-01-01

    The diagnosis of hepatic rupture in patients with pregnancy-induced hypertension (preeclampsia and eclampsia) is rarely made preoperatively. Diagnostic imaging can be utilized in some patients to confirm the preoperative diagnosis. Since hematoma formation precedes hepatic rupture, then, when diagnostic modalities such as sonography and computed tomography identify patients with hematomas, these patients are at risk of rupture, and should be hospitalized until the hematomas resolve

  11. CT-Guided Percutaneous Step-by-Step Radiofrequency Ablation for the Treatment of Carcinoma in the Caudate Lobe

    Science.gov (United States)

    Dong, Jun; Li, Wang; Zeng, Qi; Li, Sheng; Gong, Xiao; Shen, Lujun; Mao, Siyue; Dong, Annan; Wu, Peihong

    2015-01-01

    Abstract The location of the caudate lobe and its complex anatomy make caudate lobectomy and radiofrequency ablation (RFA) under ultrasound guidance technically challenging. The objective of the exploratory study was to introduce a novel modality of treatment of lesions in caudate lobe and discuss all details with our experiences to make this novel treatment modality repeatable and educational. The study enrolled 39 patients with liver caudate lobe tumor first diagnosed by computerized tomography (CT) or magnetic resonance imaging (MRI). After consultation of multi-disciplinary team, 7 patients with hepatic caudate lobe lesions were enrolled and accepted CT-guided percutaneous step-by-step RFA treatment. A total of 8 caudate lobe lesions of the 7 patients were treated by RFA in 6 cases and RFA combined with percutaneous ethanol injection (PEI) in 1 case. Median tumor diameter was 29 mm (range, 18–69 mm). A right approach was selected for 6 patients and a dorsal approach for 1 patient. Median operative time was 64 min (range, 59–102 min). Median blood loss was 10 mL (range, 8-16 mL) and mainly due to puncture injury. Median hospitalization time was 4 days (range, 2–5 days). All lesions were completely ablated (8/8; 100%) and no recurrence at the site of previous RFA was observed during median 8 months follow-up (range 3–11 months). No major or life-threatening complications or deaths occurred. In conclusion, percutaneous step-by-step RFA under CT guidance is a novel and effective minimally invasive therapy for hepatic caudate lobe lesions with well repeatability. PMID:26426638

  12. PET/CT-guided treatment planning for paediatric cancer patients: a simulation study of proton and conventional photon therapy

    Science.gov (United States)

    Brodin, N P; Björk-Eriksson, T; Birk Christensen, C; Kiil-Berthelsen, A; Aznar, M C; Hollensen, C; Markova, E; Munck af Rosenschöld, P

    2015-01-01

    Objective: To investigate the impact of including fluorine-18 fludeoxyglucose (18F-FDG) positron emission tomography (PET) scanning in the planning of paediatric radiotherapy (RT). Methods: Target volumes were first delineated without and subsequently re-delineated with access to 18F-FDG PET scan information, on duplicate CT sets. RT plans were generated for three-dimensional conformal photon RT (3DCRT) and intensity-modulated proton therapy (IMPT). The results were evaluated by comparison of target volumes, target dose coverage parameters, normal tissue complication probability (NTCP) and estimated risk of secondary cancer (SC). Results: Considerable deviations between CT- and PET/CT-guided target volumes were seen in 3 out of the 11 patients studied. However, averaging over the whole cohort, CT or PET/CT guidance introduced no significant difference in the shape or size of the target volumes, target dose coverage, irradiated volumes, estimated NTCP or SC risk, neither for IMPT nor 3DCRT. Conclusion: Our results imply that the inclusion of PET/CT scans in the RT planning process could have considerable impact for individual patients. There were no general trends of increasing or decreasing irradiated volumes, suggesting that the long-term morbidity of RT in childhood would on average remain largely unaffected. Advances in knowledge: 18F-FDG PET-based RT planning does not systematically change NTCP or SC risk for paediatric cancer patients compared with CT only. 3 out of 11 patients had a distinct change of target volumes when PET-guided planning was introduced. Dice and mismatch metrics are not sufficient to assess the consequences of target volume differences in the context of RT. PMID:25494657

  13. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  14. RESEARCH ON REDUCING PREMATURITY RUPTURE OF MEMBRANE

    Directory of Open Access Journals (Sweden)

    Maria URSACHI (BOLOTA

    2016-12-01

    Full Text Available The membranes surrounding the amniotic cavity are composed from amnion and chorion, tightly adherent layers which are composed of several cell types, including epithelial cells, trophoblasts cells and mesenchyme cells, embedded in a collagenous matrix. They retain amniotic fluid, secret substances into the amniotic fluid, as well as to the uterus and protect the fetus against upward infections from urogenital tract. Normally, the membranes it breaks during labor. Premature rupture of the amniotic sac (PRAS is defined as rupture of membranes before the onset of labor. Premature rupture of the fetal membrane, which occurs before 37 weeks of gestation, usually, refers to preterm premature rupture of membranes. Despite advances in the care period, premature rupture of membranes and premature rupture of membranes preterm continue to be regarded as serious obstetric complications. On the term 8% - 10% of pregnant women have premature rupture of membranes; these women are at increased risk of intrauterine infections, where the interval between membrane rupture and expulsion is rolled-over. Premature rupture of membranes preterm occurs in approximately 1% of all pregnancies and is associated with 30% -40% of preterm births. Thus, it is important to identify the cause of pre-term birth (after less than 37 completed weeks of "gestation" and its complications, including respiratory distress syndrome, neonatal infection and intraventricular hemorrhage. Objectives: the development of the protocol of the clinical trial on patients with impending preterm birth, study clinical and statistical on the socio-demographic characteristics of patients with imminent preterm birth; clinical condition of patients and selection of cases that could benefit from the application of interventional therapy; preclinical investigation (biological and imaging of patients with imminent preterm birth; the modality therapy; clinical investigation of the effectiveness of short

  15. Splenic rupture masquerading ruptured ectopic pregnancy | Kigbu ...

    African Journals Online (AJOL)

    The classical triad of presentation of delayed menses, irregular vaginal bleeding and abdominal pain may not be encountered at all! Overwhelming features of abdominal pain, amenorrhea, pallor, abdominal tenderness, shifting dullness with positive pregnancy test gave a clinical diagnosis of ruptured ectopic pregnancy.

  16. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  17. Efficacy of CT-guided biopsies of the spine in patients with spondylitis – an analysis of 164 procedures

    International Nuclear Information System (INIS)

    Heyer, Christoph M.; Brus, Lisa-Johanna; Peters, Soeren A.; Lemburg, Stefan P.

    2012-01-01

    Objective: To evaluate efficacy of CT-guided spinal biopsy (CTSB) in patients with spondylitis considering patient characteristics, technical issues, antibiotic therapy, histopathological, and microbiological findings. Materials and methods: All CTSB procedures performed between 1995 and 2009 in patients with proven spondylitis were re-evaluated. Patient sex and age, antibiotic treatment, biopsy approach, number of specimens, length of needle path, laboratory results (CRP, WBC), and histopathological/microbiological findings were documented and compared to the final diagnosis of spondylitis. Statistical analysis was performed using Chi-square test and Student's t-test. The p-value was set to 5%. Results: 164 CTSB procedures were performed in 159 patients (mean age 65 years, 60% men) in which spondylitis was histopathologically verified in 95%. Neither patient sex nor age, positioning, localization of the spinal lesion, bioptic approach, number of specimens, or depth of the needle showed significant impact on the rate of positive histopathological findings. A causative germ was identified in 40/127 biopsies (32%) with Staphylococcus aureus being identified in 50%. Tuberculous spondylitis was diagnosed in ten cases (6%). CRP significantly correlated with bacterial growth (13.3 ± 12.2 mg/dl versus 8.8 ± 7.6 mg/dl; p = .015) whereas administration of antibiotics did not show any significant impact on bacterial growth (29% versus 36% in patients without antibiotics; p = 0.428). Patients with histopathological signs of active spondylitis showed a significantly higher CRP (16.5 ± 15.8 mg/dl versus 8.9 ± 8.0 mg/dl, p < .001). Complication rate was 0.6% (one focal bleeding). Conclusion: CTSB of the spine in suspected spondylitis is an effective and safe procedure for establishing final histopathological diagnosis. However, microbiological yield is low regardless of technical issues and antibiotic therapy. Other than CRP values, laboratory investigations added little

  18. Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Feng; Ahunbay, Ergun; Lawton, Colleen; Allen Li, X., E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States)

    2014-03-15

    Purpose: To quantify interfractional anatomic variations and limitations of the current practice of image-guided radiation therapy (IGRT) for prostate-bed patients and to study dosimetric benefits of an online adaptive replanning scheme that addresses the interfractional variations. Methods: Contours for the targets and organs at risk (OARs) from daily diagnostic-quality CTs acquired with in-room CT (CTVision, Siemens) were generated by populating the planning contours using an autosegmentation tool based on deformable registration (ABAS, Elekta) with manual editing for ten prostate-bed patients treated with postoperative daily CT-guided IMRT. Dice similarity coefficient (DSC) obtained by maximizing the overlap of contours for a structure between the daily and plan contours was used to quantify the organ deformation between the plan and daily CTs. Three interfractional-variation-correction schemes, the current standard practice of IGRT repositioning, a previously developed online adaptive RT (ART), and the full reoptimization, were applied to these daily CTs and a number of dose-volume quantities for the targets and organs at risk were compared for their effectiveness to account for the interfractional variations. Results: Large interfractional organ deformations in prostate-bed irradiation were seen. The mean DSCs for CTV, rectum, and bladder were 86.6 ± 5.1% (range from 61% to 97%), 77.3% ± 7.4% (range from 55% to 90%), and 75.4% ± 11.2% (range from 46% to 96%), respectively. The fractional and cumulative dose-volume quantities for CTV and PTV: V100 (volume received at least 100% prescription dose), and rectum and bladder: V{sub 45Gy} and V{sub 60Gy} (volume received at least 45 or 60 Gy), were compared for the repositioning, adaptive, reoptimization, and original plans. The fractional and cumulative dosimetric results were nearly the same. The average cumulative CTV V100 were 88.0%, 98.4%, 99.2%, and 99.3% for the IGRT, ART, reoptimization, and original plans

  19. CT-guided percutaneous vertebroplasty combined with 125I-seed implantation for metastatic vertebral carcinoma involving the spinal canal: analysis of 23 cases

    International Nuclear Information System (INIS)

    Xie Xiaoxi; Lu Yinxiang; Ji Yong; Wang Xiaowei; Zhang Guodong

    2014-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous vertebroplasty (PVP) combined with 125 I-seed implantation for the treatment of metastatic vertebral carcinoma involving the spinal canal. Methods: A total of 28 involved vertebrae were detected in 23 patients with metastatic vertebral carcinoma. Each patient had 1-2 diseased vertebrae. The lesions included cervical vertebra (n=4), thoracic vertebra (n=13) and lumbar vertebra (n=11). Destroyed posterior vertebral wall was seen in all involved vertebrae. Thirteen vertebrae found in 12 patients showed involvement of the epidural space. According to treatment planning system (TPS) CT-guided implantation of 125 I seeds was carried out first for cervical lesions, which was followed by PVP. For the thoracic and lumbar lesions, unilateral or bilateral puncturing with several particle needles was employed to implant the 125 I seeds, then, PVP with bone cement injection was performed. The complications and the clinical efficacy were analyzed. Results: Successful operation was obtained in all patients. The number of implanted 125 I seeds ranged from 4 to 30 per vertebra, and the volume of injected bone cement was 1-6 ml per vertebra. After the operation the pain relief rate was 86.9% (n=20). The incidence of bone cement leakage was 17.8% (5/28). One patient had radicular pain caused by neuropore leakage, which was relieved after medication. No serious complications, such as spinal cord injury or radiation myelitis, occurred. Conclusion: CT-guided PVP combined with 125 I-seed implantation is effective and safe for the treatment of metastatic vertebral carcinoma involving the spinal canal. This therapy can effectively relieve the pain and control the deterioration of tumor, besides, the incidence of bone cement leakage is very low. (authors)

  20. Premature rupture of membranes

    Science.gov (United States)

    ... gov/ency/patientinstructions/000512.htm Premature rupture of membranes To use the sharing features on this page, ... water that surrounds your baby in the womb. Membranes or layers of tissue hold in this fluid. ...

  1. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  2. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  3. Spontaneous forniceal rupture: Can it be treated conservatively?

    Directory of Open Access Journals (Sweden)

    Ahmed Gaber Al-mujalhem

    2017-01-01

    Conclusion: Spontaneous forniceal rupture is more likely to occur with smaller distal ureteric stones. Conservative management is a valid option in non-complicated cases. Intervention should be reserved to complicated cases or cases with sizable urinoma.

  4. Ruptured cornual pregnancy

    International Nuclear Information System (INIS)

    Hussain, M.; Yasmeen, H.; Noorani, K.

    2003-01-01

    A case of ruptured cornual pregnancy is presented here. The patient presented with history of 30 weeks gestational amenorrhoea and pain in the lower abdomen and epigastrium for the last seven days. Ultrasound revealed a 29 weeks abdominal pregnancy with blood in the pelvic cavity. On laparotomy; there was a ruptured right cornual pregnancy, treated cornual resection and uterine repair. An alive male baby of one kg weight was delivered from the resected cornua of the uterus. (author)

  5. CT-guided injection of botulinic toxin for percutaneous therapy of piriformis muscle syndrome with preliminary MRI results about denervative process

    Energy Technology Data Exchange (ETDEWEB)

    Fanucci, E.; Masala, S.; Sodani, G.; Varrucciu, V.; Romagnoli, A.; Squillaci, E.; Simonetti, G. [Dept. of Radiology, Univ. of Rome (Italy)

    2001-12-01

    Piriformis muscle syndrome (PMS) is a cause of sciatica, leg or buttock pain and disability. The pain is usually increased by muscular contraction, palpation or prolonged sitting. The aim of our paper was to evaluate the feasibility of CT-guided percutaneous botulinic toxin (BTX) injection for the purpose of PMS treatment. Thirty patients suffering from PMS, suspected with clinical and electrophysiological criteria, after imaging examinations excluding other causes of sciatic pain, resulted positive at the lidocaine test and were treated by intramuscular injection of BTX type A under CT guidance. The follow-up (12 months) was performed with clinical examination in all cases and with MR 3 months after the procedure in 9 patients to evaluate the denervative process entity of the treated muscle. In 26 cases relief of symptoms was obtained after 5-7 days. In 4 patients an insufficient relief of pain justified a second percutaneous treatment which was clinically successful. No complications or side effects were recorded after BTX injection. The MR examination showed a signal intensity change of the treated muscle in 7 patients due to the denervative process of PM, whereas in the remaining 2 cases only an atrophy of the treated muscle was detected. Larger series are necessary to confirm these MRI preliminary results. The CT-guided BTX injection in the PMS is an emergent and feasible technique that obtains an excellent local therapeutic effect without risk of imprecise inoculation. (orig.)

  6. Prospective 1-year follow-up pilot study of CT-guided microwave ablation in the treatment of bone and soft-tissue malignant tumours

    Energy Technology Data Exchange (ETDEWEB)

    Aubry, Sebastien; Kastler, Bruno [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); University of Franche-Comte, I4S laboratory, INSERM EA4268, Besancon (France); Dubut, Jonathan; Nueffer, Jean-Philippe [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Chaigneau, Loic [University Hospital of Besancon, Department of Oncology, Besancon (France); Vidal, Chrystelle [University Hospital of Besancon, Clinical Investigation Center, INSERM CIT808, Besancon (France)

    2017-04-15

    The aims of this work were to assess the feasibility, efficacy, short-term outcome and safety of microwave ablation (MWA) in the treatment of malignant musculoskeletal tumours. Sixteen bone and soft-tissue malignant tumours were prospectively included and were treated by CT-guided MWA. The percentage and size of necrosis of the lesions were measured by contrast-enhanced MRI before the procedure and after 1, 3, 6 and 12 months. mRECIST criteria were used to assess tumour response. Procedural success was defined as ≥80 % necrosis. Patient pain (as assessed using a numeric visual scale (NVS)) and side effects were noted. Six osteolytic metastases, five osteoblastic metastases and five soft tissue sarcomas were treated. At 1 month, 40 % were treated completely, the percentage of necrosis was 85 ± 30.4 %, and the success rate was 80 %. At 3, 6 and 12 months the success rate was 80 %, 76.9 % and 63.6 %, respectively. At 12 months, four lesions (36.3 %) still had no recurrence. Mean NVS during the procedure was 3.5 ± 2.8. One patient had transitory sciatica without neurological deficit that was treated medically. CT-guided MWA of bone and soft-tissue malignant tumours is efficient, well tolerated and has good short-term anti-cancer effects. (orig.)

  7. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    Science.gov (United States)

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  8. CT-guided percutaneous laser disc decompression with Ceralas D, a diode laser with 980-nm wavelength and 200-μm fiber optics

    International Nuclear Information System (INIS)

    Gevargez, A.; Groenemeyer, D.W.H.; Czerwinski, F.

    2000-01-01

    The aim of this study was to evaluate the compact, portable Ceralas-D diode laser (CeramOptec; 980+30 nm wavelength, 200-μm optical fiber) concerning clinical usefulness, handling, and clinical results in the CT-guided treatment of herniated lumbar discs. The positioning of the canula in intradiscal space, the placement of the laser fiber into the disc through the lying canula, and the vaporization itself were carried out under CT-guidance. Due to the thin fiber optic, it was possible to use a thin 23-gauge canula. The laser procedure was performed in 0.1- to 1-s shots with 1-s pulse pause and 4-W power output. A total of 1650-2300 J was applied on each percutaneous laser disc decompression (PLDD). Results in 26 patients were established with a visual-analogue scale (VAS). On the follow-up examinations, 46% of the patients were absolutely pain free (>85% VAS) and fully active in everyday life after 4 postoperative weeks. Thirty-one percent of patients were relieved of the leg pain but had occasional back pain without sensorimotor impairment. Fifteen percent sensed a slight alleviation (>50% VAS) of the radiate pain. Eight percent did not experience radicular or pseudo-radicular pain alleviation (<25% VAS). Cerales-D proves to be an efficient tool for CT-guided PLDD on non-sequestered herniated lumbar discs. (orig.)

  9. CT-guided stellate ganglion blockade vs. radiofrequency neurolysis in the management of refractory type I complex regional pain syndrome of the upper limb

    Energy Technology Data Exchange (ETDEWEB)

    Kastler, Adrian [University Hospital CHU Gabriel Montpied, Radiology Department, Clermont-Ferrand (France); Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France); CHU Clermont-Ferrand, Hopital Gabriel Montpied, Clermont-Ferrand (France); Aubry, Sebastien; Kastler, Bruno [University Hospital CHU Jean Minjoz, Radiology and Interventional Pain Unit, Besancon (France); Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France); Sailley, Nicolas; Michalakis, Demosthene [University Hospital CHU Jean Minjoz, Radiology and Interventional Pain Unit, Besancon (France); Siliman, Gaye [University Hospital CHU St Jacques, Clinical Investigation Center, Besancon (France); Gory, Guillaume [Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France); Lajoie, Jean-Louis [University Hospital CHU Jean Minjoz, Pain evaluation and Management Unit, Besancon (France)

    2013-05-15

    To describe and evaluate the feasibility and efficacy of CT-guided radiofrequency neurolysis (RFN) vs. local blockade of the stellate ganglion in the management of chronic refractory type I complex regional pain syndrome (CRPS) of the upper limb. Sixty-seven patients were included in this retrospective study between 2000 and 2011. All suffered from chronic upper limb type I CRPS refractory to conventional pain therapies. Thirty-three patients underwent stellate ganglion blockade and 34 benefited from radiofrequency neurolysis of the stellate ganglion. CT guidance was used in both groups. The procedure was considered effective when pain relief was {>=}50 %, lasting for at least 2 years. Thirty-nine women (58.2 %) and 28 men (41.8 %) with a mean age of 49.5 years were included in the study. Univariate analysis performed on the blockade and RFN groups showed a significantly (P < 0.0001) higher success rate in the RFN group (67.6 %, 23/34) compared with the blockade group (21.2 %, 7/33) with an odds ratio of 7.76. CT-guided radiofrequency neurolysis of the stellate ganglion is a safe and successful treatment of chronic refractory type I CRPS of the upper limb. It appears to be more effective than stellate ganglion blockade. (orig.)

  10. Long-term results of CT-guided percutaneous radiofrequency ablation of inoperable patients with stage Ia non-small cell lung cancer: A retrospective cohort study.

    Science.gov (United States)

    Huang, Bing-Yang; Li, Xin-Min; Song, Xiao-Yong; Zhou, Jun-Jun; Shao, Zhuang; Yu, Zhi-Qi; Lin, Yi; Guo, Xin-Yu; Liu, Da-Jiang; Li, Lu

    2018-05-01

    This study was performed to retrospectively evaluate the 10-year overall survival (OS), progression-free survival (PFS), and local control rates of patients with inoperable stage Ia non-small cell lung cancer (NSCLC) who underwent computed tomography (CT)-guided radiofrequency ablation (RFA) in a single center. Fifty patients with inoperable NSCLC underwent RFA between 2004 and 2016. Thoracic surgeons evaluated the patients and performed RFA under CT guidance. Follow-up CT and positron emission tomography/CT scans were obtained. Local control rates and recurrence patterns were analyzed. Seventy-three lesions in 50 patients (M:F = 22:28; median age: 73 years; range: 52-82 years) were treated with CT-guided RFA. The mean lesion size was 2.2 cm (range: 1-3 cm). No procedure-related deaths occurred. Low-grade fever was the most common post-ablation complication, with an incidence rate of 36%. The 1-, 2-, 3-, 5-, and 10-year OS rates of patients with Ia NSCLC were 96.0%, 86.5%, 67.1%, 36.3%, and 1%, respectively, and the 1-, 2-, 3-, and 5-year PFS rates were 94.0%, 77.5%, 43.5%, and 10.8%, respectively. The most common pattern of recurrence was local, and 15 patients with recurrence were treated with repeat RFA. Tumor size Ia NSCLC. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  11. CT-guided radiofrequency ablation of osteoid osteoma and osteoblastoma: Clinical success and long-term follow up in 77 patients

    International Nuclear Information System (INIS)

    Rehnitz, Christoph; Sprengel, Simon David; Lehner, Burkhard; Ludwig, Karl; Omlor, Georg; Merle, Christian; Kauczor, Hans-Ulrich; Ewerbeck, Volker; Weber, Marc-André

    2012-01-01

    The purpose of this study was to retrospectively evaluate long-term success of CT-guided radiofrequency ablation (RFA) in patients with osteoid osteoma (OO) and osteoblastoma (OB) including tumors in critical locations. Eighty-one CT-guided RFA procedures were performed in 77 patients with OO (65 patients) and OB (12) including 6 spinal and 15 intra/periarticular tumors. Procedural techniques included multiple needle positions, three-dimensional access planning, as well as, thermal protection techniques. Long-term success was assessed using a questionnaire including, among others, several VAS (visual analogue scale) scores. All patients completed 3–6 months follow-up, overall response to the questionnaire was 64/77 (83.1%). Primary success rate was 74/77 (96.1%) of all patients. Retreatment with RFA in 3 patients resulted in a secondary success rate of 77/77 (100%). Long-term follow-up (mean, 38.5 months; range, 3–92) revealed a highly significant (p < 0.001) reduction of all assessed limitation scores reaching normal or almost normal values. One major complication, a cannula break leading to a secondary short hospital stay, occurred. In conclusion, RFA is a safe and effective long-lasting treatment of OO and OB. Advanced procedural techniques aid treating tumors in critical locations and in the coverage of larger tumors. Besides night pain, RFA also greatly improves other factors negatively affecting the quality of life.

  12. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Influence able and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique-Case Report, Systematic Literature Review, and a Technical Note

    International Nuclear Information System (INIS)

    Rott, G.; Boecker, F.

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influence able or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemo static valve.

  14. PET/CT-guided percutaneous liver mass biopsies and ablations: Targeting accuracy of a single 20 s breath-hold PET acquisition

    International Nuclear Information System (INIS)

    Shyn, P.B.; Tatli, S.; Sahni, V.A.; Sadow, C.A.; Forgione, K.; Mauri, G.; Morrison, P.R.; Catalano, P.J.; Silverman, S.G.

    2014-01-01

    Aim: To determine whether a single 20 s breath-hold positron-emission tomography (PET) acquisition obtained during combined PET/computed tomography (CT)-guided percutaneous liver biopsy or ablation procedures has the potential to target 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG)-avid liver masses as accurately as up to 180 s breath-hold PET acquisitions. Materials and methods: This retrospective study included 10 adult patients with 13 liver masses who underwent FDG PET/CT-guided percutaneous biopsies (n = 5) or ablations (n = 5). PET was acquired as nine sequential 20 s, monitored, same-level breath-hold frames and CT was acquired in one monitored breath-hold. Twenty, 40, 60, and 180 s PET datasets were reconstructed. Two blinded readers marked tumour centres on randomized PET and CT datasets. Three-dimensional spatial localization differences between PET datasets and either 180 s PET or CT were analysed using multiple regression analyses. Statistical tests were two-sided and p < 0.05 was considered significant. Results: Targeting differences between 20 s PET and 180 s PET ranged from 0.7–20.3 mm (mean 5.3 ± 4.4 mm; median 4.3) and were not statistically different from 40 or 60 s PET (p = 0.74 and 0.91, respectively). Targeting differences between 20 s PET and CT ranged from 1.4–36 mm (mean 9.6 ± 7.1 mm; median 8.2 mm) and were not statistically different from 40, 60, or 180 s PET (p = 0.84, 0.77, and 0.35, respectively). Conclusion: Single 20 s breath-hold PET acquisitions from PET/CT-guided percutaneous liver procedures have the potential to target FDG-avid liver masses with equivalent accuracy to 180 s summed, breath-hold PET acquisitions and may facilitate strategies that improve image registration and shorten procedure times

  15. Combined CT-guided radiofrequency ablation with systemic chemotherapy improves the survival for nasopharyngeal carcinoma with oligometastasis in liver: Propensity score matching analysis.

    Science.gov (United States)

    Li, Wang; Bai, Yutong; Wu, Ming; Shen, Lujun; Shi, Feng; Sun, Xuqi; Lin, Caijin; Chang, Boyang; Pan, Changchuan; Li, Zhiwen; Wu, Peihong

    2017-08-08

    The aim of this study was to retrospectively compare the treatment efficacy of systemic chemotherapy combined with sequential CT-guided radiofrequency ablation (Chemo-RFA) to chemotherapy alone (Chemo-only) in the management of nasopharyngeal carcinoma (NPC) with liver metastasis. Between 2003 and 2011, 328 NPC patients diagnosed with liver metastasis at Sun Yat-sen University Cancer Center were enrolled. One-to-one matched pairs between Chemo-RFA group with the Chemo-only group were generated using propensity score matching. The associations of treatment modality with overall survival (OS) and progression-free survival (PFS) were determined by Cox regression. Of the patients enrolled, 37 patients (11.8 %) received combined treatment, 291 (82.2) received chemotherapy alone. The patients in Chemo-RFA group were more frequently classified as lower number (≤3) of liver metastatic lesions (Poligometastasis in liver, and should be considered if the ablation is technically feasible.

  16. CT-guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver malignancies; CT-gesteuerte Brachytherapie. Eine neue perkutane Technik zur interstitiellen Ablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J.; Wust, P.; Stohlmann, A.; Beck, A.; Cho, C.H.; Pech, M.; Wieners, G.; Spors, B.; Werk, M.; Rosner, C.; Haenninen, E.L.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany)

    2004-05-01

    Purpose: to assess safety and efficacy of CT-guided brachytherapy of liver malignancies. Patients and methods: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a {sup 192}Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size {>=} 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. Results: the mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. Conclusion: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization. (orig.) [German] Ziel: Analyse der Sicherheit und Effektivitaet CT-gesteuerter Brachytherapie zur Ablation von Lebermalignomen. Patienten und Methodik: 21 Patienten mit 21 Lebermalignomen (19 Metastasen, zwei primaere Lebermalignome) wurden mit perkutaner, CT-gesteuerter interstitieller Brachytherapie mit {sup 192}Ir behandelt. Alle Patienten wiesen Umstaende auf, die eine bildgefuehrte thermische Ablation mit Radiofrequenz oder laserinduzierter Thermotherapie (LITT) einschraenkten

  17. CT-guided needle biopsy in the diagnosis of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue: a rare combination.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2015-01-01

    We represent a rare case of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT). The patient was a 66-year-old male presented with 1 month history of recurrent cough and hemoptysis. Chest CT showed solitary ground-glass opacity (GGO) in the upper lobe of the right lung and mediastinal lymph node enlargement in station 3p. A CT-guided transthoracic needle biopsy was performed. Tissue specimens of the GGO revealed a typical adenocarcinoma. Histopathologic diagnosis of mediastinal lymph node was extranodal marginal zone lymphoma of MALT. Because of its rarity, extranodal marginal zone lymphoma of MALT should be considered in the differential diagnosis when we encounter mediastinal lymphadenopathy in patients with lung adenocarcinoma.

  18. Rupture, waves and earthquakes.

    Science.gov (United States)

    Uenishi, Koji

    2017-01-01

    Normally, an earthquake is considered as a phenomenon of wave energy radiation by rupture (fracture) of solid Earth. However, the physics of dynamic process around seismic sources, which may play a crucial role in the occurrence of earthquakes and generation of strong waves, has not been fully understood yet. Instead, much of former investigation in seismology evaluated earthquake characteristics in terms of kinematics that does not directly treat such dynamic aspects and usually excludes the influence of high-frequency wave components over 1 Hz. There are countless valuable research outcomes obtained through this kinematics-based approach, but "extraordinary" phenomena that are difficult to be explained by this conventional description have been found, for instance, on the occasion of the 1995 Hyogo-ken Nanbu, Japan, earthquake, and more detailed study on rupture and wave dynamics, namely, possible mechanical characteristics of (1) rupture development around seismic sources, (2) earthquake-induced structural failures and (3) wave interaction that connects rupture (1) and failures (2), would be indispensable.

  19. Traumatic rupture of the aorta

    International Nuclear Information System (INIS)

    Dorfman, G.S.; Paolella, L.P.; Haas, R.A.; Lambiase, R.E.; Cronan, J.J.

    1988-01-01

    To evaluate the acceptability of digital subtraction angiography (DSA) in the evaluation of traumatic rupture of the aorta (TRA), the authors obtained 56 thoracic aortograms in 55 consecutive trauma patients, using both DSA and cut-film angiography (CFA). Both studies were ranked blindly and assigned scores for quality and diagnosis. Interobserver variance for DSA and CFA quality rankings was insignificant. CFA achieved significantly higher ranking for quality. In the 56 examinations, CFA demonstrated seven abnormalities that demanded intervention for follow-up angiography. DSA demonstrated only five of these and found no additional abnormalities. While this evaluation applies only to the particular digital system that the authors tested, they found that DSA, as compared with CFA, failed to demonstrate significant aortic injury. The confidence of diagnosis was significantly greater with CFA. Similar double-blind evaluation is mandatory at any trauma center prior to converting from CFA to DSA in the diagnosis of this life-threatening condition

  20. CT-guided percutaneous screw fixation plus cementoplasty in the treatment of painful bone metastases with fractures or a high risk of pathological fracture

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio; Ballicu, Nicola; Fele, Rosa Maria; Sotgia, Barbara; Melis, Luca [Oncological Hospital ' ' A. Businco' ' , Regional Referral Center for Oncologic Diseases, Division of Interventional Radiology, Department of Oncological Radiology, Cagliari (Italy); Fancellu, Alessandro [University of Sassari, Department of Clinical and Experimental Medicine, Sassari (Italy)

    2017-04-15

    To evaluate the feasibility and effectiveness of computed tomography (CT)-guided percutaneous screw fixation plus cementoplasty (PSFPC), for either treatment of painful metastatic fractures or prevention of pathological fractures, in patients who are not candidates for surgical stabilization. Twenty-seven patients with 34 metastatic bone lesions underwent CT-guided PSFPC. Bone metastases were located in the vertebral column, femur, and pelvis. The primary end point was the evaluation of feasibility and complications of the procedure, in addition to the length of hospital stay. Pain severity was estimated before treatment and 1 and 6 months after the procedure using the visual analog scale (VAS). Functional outcome was assessed by improved patient walking ability. All sessions were completed and well tolerated. There were no complications related to either incorrect positioning of the screws during bone fixation or leakage of cement. All patients were able to walk within 6 h after the procedure and the average length of hospital stay was 2 days. The mean VAS score decreased from 7.1 (range, 4-9) before treatment to 1.6 (range, 0-6), 1 month after treatment, and to 1.4 (range 0-6) 6 months after treatment. Neither loosening of the screws nor additional bone fractures occurred during a median follow-up of 6 months. Our results suggest that PSFPC might be a safe and effective procedure that allows the stabilization of the fracture and the prevention of pathological fractures with significant pain relief and good recovery of walking ability, although further studies are required to confirm this preliminary experience. (orig.)

  1. Diffusion-weighted imaging for pretreatment evaluation and prediction of treatment effect in patients undergoing CT-guided injection for lumbar disc herniation

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    To determine whether a change in apparent diffusion coefficient (ADC) value could predict early response to CT-guided Oxygen-Ozone (O 2 -O 3 ) injection therapy in patients with unilateral mono-radiculopathy due to lumbar disc herniation. A total of 52 patients with unilateral mono-radiculopathy received a single intradiscal (3 mL) and periganglionic (5 mL) injection of an O 2 -O 3 mixture. An ADC index of the involved side to the intact side was calculated using the following formula: pre-treatment ADC index = ([ADC involved side - ADC intact side] / ADC intact side) x 100. We analyzed the relationship between the pre-treatment Oswestry Disability Index (ODI) and the ADC index. In addition, the correlation between ODI recovery ratio and ADC index was investigated. The sensitivity and specificity of the ADC index for predicting response in O 2 -O 3 therapy was determined. Oswestry Disability Index and the ADC index was not significantly correlated (r = -0.125, p = 0.093). The ADC index and ODI recovery ratio was significantly correlated (r = 0.819, p < 0.001). When using 7.10 as the cut-off value, the ADC index obtained a sensitivity of 86.3% and a specificity of 82.9% for predicting successful response to therapy around the first month of follow-up. This preliminary study demonstrates that the patients with decreased ADC index tend to show poor improvement of clinical symptoms. The ADC index may be a useful indicator to predict early response to CT-guided O 2 -O 3 injection therapy in patients with unilateral mono-radiculopathy due to lumbar disc herniation

  2. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  3. Feasibility and clinical value of CT-guided {sup 125}I brachytherapy for metastatic soft tissue sarcoma after first-line chemotherapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Zhiqiang; Zhang, Yanling; Xiang, Zhanwang; Yan, Huzhen; Zhong, Zhihui; Gao, Fei; Zhang, Fujun [Sun Yat-Sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangzhou (China); Zhang, Tao [Guangzhou Medical University, Department of Interventional Radiology and Vascular Anomalies, Guangzhou Women and Children' s Medical Centre, Guangzhou (China)

    2018-03-15

    To evaluate the feasibility and usefulness of computed tomography (CT)-guided iodine{sup 125} ({sup 125}I) brachytherapy for patients with metastatic soft tissue sarcoma (STS) after first-line chemotherapy failure. We recruited 93 patients with metastatic STS who had received first-line chemotherapy 4-6 times but developed progressive disease, from January 2010 to July 2015; 45 patients who had combined {sup 125}I brachytherapy and second-line chemotherapy (Group A), and 48 patients who received second-line CT only (Group B). In Group A, 49 {sup 125}I seed implantation procedures were performed in 45 patients with 116 metastatic lesions; the primary success rate was 91.1% (41/45), without life-threatening complications. Local control rates at 3, 6, 12, 24 and 36 months were 71.1%, 62.2%, 46.7%, 28.9% and 11.1% for Group A, and 72.9%, 54.2%, 18.8%, 6.3% and 0% for Group B. Mean progression-free survival differed significantly (Group A: 7.1±1.3 months; Group B: 3.6 ±1.1 months; P<0.001; Cox proportional hazards regression analysis), but overall survival did not significantly differ (Group A: 16.9 ±5.1 months; Group B: 12.1 ± 4.8 months). Group A showed better symptom relief and quality of life than Group B. CT-guided {sup 125}I brachytherapy is a feasible and valuable treatment for patients with metastatic STS. (orig.)

  4. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Michael C.; Atwell, Thomas D.; King, Bernard F.; Welch, Timothy; Goenka, Ajit H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mynderse, Lance A. [Mayo Clinic, Department of Urology, Rochester, MN (United States)

    2017-08-15

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. (orig.)

  5. Diffusion-weighted imaging for pretreatment evaluation and prediction of treatment effect in patients undergoing CT-guided injection for lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Schuan Key Laboratory of Medical Imaging and Dept. of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-08-15

    To determine whether a change in apparent diffusion coefficient (ADC) value could predict early response to CT-guided Oxygen-Ozone (O{sub 2}-O{sub 3}) injection therapy in patients with unilateral mono-radiculopathy due to lumbar disc herniation. A total of 52 patients with unilateral mono-radiculopathy received a single intradiscal (3 mL) and periganglionic (5 mL) injection of an O{sub 2}-O{sub 3} mixture. An ADC index of the involved side to the intact side was calculated using the following formula: pre-treatment ADC index = ([ADC involved side - ADC intact side] / ADC intact side) x 100. We analyzed the relationship between the pre-treatment Oswestry Disability Index (ODI) and the ADC index. In addition, the correlation between ODI recovery ratio and ADC index was investigated. The sensitivity and specificity of the ADC index for predicting response in O{sub 2}-O{sub 3} therapy was determined. Oswestry Disability Index and the ADC index was not significantly correlated (r = -0.125, p = 0.093). The ADC index and ODI recovery ratio was significantly correlated (r = 0.819, p < 0.001). When using 7.10 as the cut-off value, the ADC index obtained a sensitivity of 86.3% and a specificity of 82.9% for predicting successful response to therapy around the first month of follow-up. This preliminary study demonstrates that the patients with decreased ADC index tend to show poor improvement of clinical symptoms. The ADC index may be a useful indicator to predict early response to CT-guided O{sub 2}-O{sub 3} injection therapy in patients with unilateral mono-radiculopathy due to lumbar disc herniation.

  6. Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

    Science.gov (United States)

    Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko

    2015-06-01

    Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid registration into routine clinical practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  7. CT-guided percutaneous intratumoral chemotherapy with a novel cisplatin/epinephrine injectable gel for the treatment of unresectable malignant liver tumors

    International Nuclear Information System (INIS)

    Engelmann, K.; Mack, M.G.; Straub, R.; Eichler, K.; Zangos, S.; Vogl, T.J.

    2000-01-01

    Purpose: To evaluate prospectively the volumetric changes of tumor and necrosis in unresectable malignant liver tumors and the clinical aspects after CT-guided direct intratumoral administration of a novel cisplatin/epinephrine injectable gel in a clinical phase II study. Patients and methods: 8 patients with 17 colorectal liver metastases with a mean volume of 42 ml were treated with a mean of 5.1 injections and 8 patients with 11 HCC nodules (mean volume of 22.1 ml) with a mean of 3.25 treatments with CT-guided local administration of a novel cisplatin/epinephrine gel. This method of administration provides a higher local and lower systemic drug concentration. Volumes of tumor and necrosis prior to and after treatment were measured by computer-generated volumetric analysis. Results: Contrast-enhanced studies verified pretherapeutic tumor necrosis with a value of 12.6% in the metastases and 0.6% in the HCC nodules. Intratumoral drug administration resulted in a necrotic volume of 110% in metastases and 128% in HCC versus the mean initial tumor volume, at least 4 treatments resulted in 122% necrosis in metastases and 130% in HCC. Local therapy control rate for the follow-up to 6 months was 38% and 83.3% for the group of metastases and HCC, respectively. Conclusions: Direct intratumoral injection of a novel cisplatin/epinephrine injectable gel results in an induction of a relevant necrosis in malignant liver tumors, with a substantially higher local therapy control rate for HCC compared to colorectal metastases. (orig.) [de

  8. Delayed ventricular septal rupture complicating acute inferior wall myocardial infarction

    OpenAIRE

    Cho, Jae Hyung; Sattiraju, Srinivasan; Mehta, Sanjay; Missov, Emil

    2013-01-01

    Background Ventricular septal rupture is a potentially fatal complication of acute myocardial infarction. Its incidence has declined with modern reperfusion therapy. In the era of percutaneous coronary interventions, it occurs a median of 18?24?hours after myocardial infarction and is most commonly associated with anterior myocardial infarction. We present a case of delayed ventricular septal rupture complicating acute inferior wall myocardial infarction. Case presentation A 53-year-old Cauca...

  9. Double rupture disc experience

    International Nuclear Information System (INIS)

    1979-01-01

    Result of these observations, comparisons and evaluations can be summarized in the following list of concerns regarding the use of double rupture discs coupled to the liquid space of a steam generator that is subjected to a large leak sodium water reaction event. Single rupture disc show delayed collapse characteristics in LLTR Series I and double disc assemblies are presumed to be more complex with additional delay before opening to give pressure relief. Delayed failure increases pressures in the IHTS and must be adequately covered by design requirements. With CRBR design, the first disc may fail only partially reducing the loading on the second disc with the result that relief performance may not meet requirements

  10. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo (Egypt); Alsubhi, Mohammed [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N. [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Alexandria University Hospital, Alexandria (Egypt); Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-10-15

    Purpose: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. Materials and methods: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. Results: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p = 0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p = 0.0003) in the non-coaxial group and 57.7% (41/71, p = 0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p = 0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion

  11. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    International Nuclear Information System (INIS)

    Nour-Eldin, Nour-Eldin A.; Alsubhi, Mohammed; Naguib, Nagy N.; Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    Purpose: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. Materials and methods: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. Results: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p = 0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p = 0.0003) in the non-coaxial group and 57.7% (41/71, p = 0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p = 0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion

  12. Ruptured liver abscess: Analysis of 50 cases

    Directory of Open Access Journals (Sweden)

    Mohit Bhatia

    2017-01-01

    Full Text Available Background: Liver abscess (pyogenic and amebic is frequently encountered clinical condition; however, it can result in lethal outcome if there is a delay in diagnosis and treatment. Despite modalities to diagnose the condition early, still ruptured liver abscess presents with a common cause of acute abdomen in surgical emergency. In developing countries, ruptured liver abscess is a common cause of mortality. For contained abscess, nonsurgical options are considered; however, for ruptured liver abscess, surgical intervention is considered necessary. Materials and Methods: This was a retrospective study carried in Safdarjung hospital, New Delhi, between 2015 and 2016. All patients with ruptured liver abscess (clear signs of peritonitis were included in this study, and those patients having other causes of peritonitis were excluded. A preformed protocol for management was followed for all the patients, and various parameters contributing to the illness and its prognosis were evaluated and assessed. Results: Out of the fifty patients assessed, male patients were mainly affected (86%. The most affected age group was 31–40 years (64% followed by 41–50 years (22%. Right hypochondrium pain was the most common presenting complaint. Nine patients (18% had presented with signs of toxemia. Only right lobe of the liver was affected the most in 44 patients (88%. Escherichia coli was the most common organism isolated in our study in 19 patients (38%. A total of 19 patients (38% had diabetes in our study and total of 13 patients had mortality in our study. Conclusion: Ruptured liver abscess most commonly involves the right lobe of the liver. Males are affected far higher than the females; probable cause believed to be higher alcohol consumption. Most common affected age group falls between 30 and 60 years of age. If prompt treatment is started in time, mortality involved with it is evitable.

  13. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  14. Does pain relief by CT-guided indirect cervical nerve root injection with local anesthetics and steroids predict pain relief after decompression surgery for cervical nerve root compression?

    Science.gov (United States)

    Antoniadis, Alexander; Dietrich, Tobias J; Farshad, Mazda

    2016-10-01

    The relationship of pain relief from a recently presented CT-guided indirect cervical nerve root injection with local anesthetics and steroids to surgical decompression as a treatment for single-level cervical radiculopathy is not clear. This retrospective study aimed to compare the immediate and 6-week post-injection effects to the short- and long-term outcomes after surgical decompression, specifically in regard to pain relief. Patients (n = 39, age 47 ± 10 years) who had undergone CT-guided indirect injection with local anesthetics and steroids as an initial treatment for single cervical nerve root radiculopathy and who subsequently needed surgical decompression were included retrospectively. Pain levels (VAS scores) were monitored before, immediately after, and 6 weeks after injection (n = 34), as well as 6 weeks (n = 38) and a mean of 25 months (SD ± 12) after surgical decompression (n = 36). Correlation analysis was performed to find potential associations of pain relief after injection and after surgery to investigate the predictive value of post-injection pain relief. There was no correlation between immediate pain relief after injection (-32 ± 27 %) and 6 weeks later (-7 ± 19 %), (r = -0.023, p = 0.900). There was an association by tendency between immediate pain relief after injection and post-surgical pain relief at 6 weeks (-82 ± 27 %), (r = 0.28, p = 0.08). Pain relief at follow-up remained high at -70 ± 21 % and was correlated with the immediate pain amelioration effect of the injection (r = 0.37, p = 0.032). Five out of seven patients who reported no pain relief from injection had a pain relief from surgery in excess of 50 %. The amount of immediate radiculopathic pain relief after indirect cervical nerve root injection is associated with the amount of pain relief achieved at long-term follow-up after surgical decompression of single-level cervical radiculopathy

  15. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  16. PET/CT-guided percutaneous biopsy of FDG-avid metastatic bone lesions in patients with advanced lung cancer: a safe and effective technique

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wei; Hao, Bing; Chen, Hao-jun; Zhao, Long; Luo, Zuo-ming; Wu, Hua; Sun, Long [The First Affiliated Hospital of Xiamen University, Department of Nuclear Medicine and Minnan PET Center, Xiamen Cancer Hospital, Xiamen (China)

    2017-01-15

    {sup 18}F-FDG PET/CT should be performed before a diagnostic biopsy site is chosen in patients with a high clinical suspicion of aggressive, advanced tumour. The aim of this study was to evaluate the safety and efficacy of {sup 18}F-FDG PET/CT in guiding biopsy of bone metastases in patients with advanced lung cancer. PET/CT-guided percutaneous core biopsies were performed in 51 consecutive patients with suspected lung cancer and {sup 18}F-FDG-avid bone lesions after whole-body {sup 18}F-FDG PET/CT scans. Generally, one tissue sample was obtained from each patient. The final diagnoses were established on the basis of the histology results. The histopathological and molecular testing results were systematically evaluated. A total of 53 samples were obtained for histological examination or molecular testing as a second biopsy was required in two patients in whom the pathological diagnosis was unclear following the first biopsy. The pathological diagnosis and lung cancer classification were confirmed in 48 patients. The epidermal growth factor receptor mutation status was determined in 23 biopsies, and the mutation rate was 30.4 % (7/23). The anaplastic lymphoma kinase mutation status was determined in 19 biopsies, and the mutation rate was 31.6 % (6/19). Two of the 51 biopsies were positive for non-Hodgkin's lymphoma and one was positive for metastatic renal cell carcinoma. The first-time diagnostic success rate of biopsy was 96.1 % (49/51) and the overall diagnostic success rate and sensitivity were 100 %. All 51 patients were eventually confirmed as having stage IV disease. No serious complications were encountered and the average biopsy time was 30 min. PET/CT-guided percutaneous biopsy of {sup 18}F-FDG-avid bone metastases is an effective and safe method that yields a high diagnostic success rate in the evaluation of hypermetabolic bone lesions in patients with suspected advanced lung cancer. (orig.)

  17. Steam generator tube rupture (SGTR) scenarios

    International Nuclear Information System (INIS)

    Auvinen, A.; Jokiniemi, J.K.; Laehde, A.; Routamo, T.; Lundstroem, P.; Tuomisto, H.; Dienstbier, J.; Guentay, S.; Suckow, D.; Dehbi, A.; Slootman, M.; Herranz, L.; Peyres, V.; Polo, J.

    2005-01-01

    The steam generator tube rupture (SGTR) scenarios project was carried out in the EU 5th framework programme in the field of nuclear safety during years 2000-2002. The first objective of the project was to generate a comprehensive database on fission product retention in a steam generator. The second objective was to verify and develop predictive models to support accident management interventions in steam generator tube rupture sequences, which either directly lead to severe accident conditions or are induced by other sequences leading to severe accidents. The models developed for fission product retention were to be included in severe accident codes. In addition, it was shown that existing models for turbulent deposition, which is the dominating deposition mechanism in dry conditions and at high flow rates, contain large uncertainties. The results of the project are applicable to various pressurised water reactors, including vertical steam generators (western PWR) and horizontal steam generators (VVER)

  18. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  19. Slow rupture of frictional interfaces

    OpenAIRE

    Sinai, Yohai Bar; Brener, Efim A.; Bouchbinder, Eran

    2011-01-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not comple...

  20. Pancreatic Pseudocyst Ruptured due to Acute Intracystic Hemorrhage

    Directory of Open Access Journals (Sweden)

    Kunishige Okamura

    2017-12-01

    Full Text Available Rupture of pancreatic pseudocyst is one of the rare complications and usually results in high mortality. The present case was a rupture of pancreatic pseudocyst that could be treated by surgical intervention. A 74-year-old man developed abdominal pain, vomiting, and diarrhea, and he was diagnosed with cholecystitis and pneumonia. Three days later, acute pancreatitis occurred and computed tomography (CT showed slight hemorrhage in the cyst of the pancreatic tail. After another 10 days, CT showed pancreatic cyst ruptured due to intracystic hemorrhage. Endoscopic retrograde cholangiopancreatography revealed leakage of contrast agent from pancreatic tail cyst to enclosed abdominal cavity. His left hypochondrial pain was increasing, and CT showed rupture of the cyst of the pancreatic tail into the peritoneal cavity was increased in 10 days. CT showed also two left renal tumors. Therefore we performed distal pancreatectomy with concomitant resection of transverse colon and left kidney. We histopathologically diagnosed pancreatic pseudocyst ruptured due to intracystic hemorrhage and renal cell carcinoma. Despite postoperative paralytic ileus and fluid collection at pancreatic stump, they improved by conservative management and he could be discharged on postoperative day 29. He has achieved relapse-free survival for 6 months postoperatively. The mortality of pancreatic pseudocyst rupture is very high if some effective medical interventions cannot be performed. It should be necessary to plan appropriate treatment strategy depending on each patient.

  1. Slow rupture of frictional interfaces

    Science.gov (United States)

    Bar Sinai, Yohai; Brener, Efim A.; Bouchbinder, Eran

    2012-02-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not completely understood. We show that slow rupture is an intrinsic and robust property of simple non-monotonic rate-and-state friction laws. It is associated with a new velocity scale cmin, determined by the friction law, below which steady state rupture cannot propagate. We further show that rupture can occur in a continuum of states, spanning a wide range of velocities from cmin to elastic wave-speeds, and predict different properties for slow rupture and ordinary fast rupture. Our results are qualitatively consistent with recent high-resolution laboratory experiments and may provide a theoretical framework for understanding slow rupture phenomena along frictional interfaces.

  2. Plantar fascia rupture in a professional soccer player.

    Science.gov (United States)

    Suzue, Naoto; Iwame, Toshiyuki; Kato, Kenji; Takao, Shoichiro; Tateishi, Tomohiko; Takeda, Yoshitsugu; Hamada, Daisuke; Goto, Tomohiro; Takata, Yoichiro; Matsuura, Tetsuya; Sairyo, Koichi

    2014-01-01

    We report the case of a 29-year-old male professional soccer player who presented with symptoms of plantar fasciitis. His symptoms occurred with no remarkable triggers and gradually worsened despite conservative treatments including taping, use of insoles, and physical therapy. Local corticosteroid injection was given twice as a further intervention, but his plantar fascia partially ruptured 49 days after the second injection. He was treated conservatively with platelet-rich plasma, and magnetic resonance imaging showed regenerative change of the ruptured fascia. Five months after the rupture, he returned to his original level of training. If professional athletes find it difficult to refrain from athletic activity, as in the present case, the risk of rupture due to corticosteroid injection should not be overlooked.

  3. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  4. Transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma located in the subphrenic region of liver

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    2000-01-01

    The purpose of this study is to evaluate the feasibility of transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma (HCC, 15 lesions) located in the subphrenic region and untreatable by ultrasonography-guided PEIT. The HCC was localized on Lipiodol CT image with a graduated grid system. We advanced a PEIT needle in a stepwise fashion, perpendicularly to the major axis of body through the lung with intermittent localization scans to position the tip of the needle in the lesion. Ethanol was injected with monitoring scans obtained after incremental volumes of injection, until perfusion was judged to be complete. A total of 20 CT-PEIT sessions were performed. The average number of needles passed from skin to liver in each CT-PEIT session was 2.7, the average volume of ethanol injected was 11.7 ml, and the average time required was 53.6 minutes. Complete perfusion of the lesion by ethanol was achieved in all lesions with only a single or double CT-PEIT procedure without severe complications. Local recurrence was detected in 3 to 15 followed up lesions for 14 months on average. In conclusion, transpulmonary CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC located in the subphrenic region. (author)

  5. Roentgeno-radiological examination for ruptures of the main bronchi and their consequences

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.; Kudryavtseva, N.F.; Nersesova, L.I.; Kon'kov, Eh.G.

    1981-01-01

    The results of roentgeno-radiological examination of patients with the main bronchial ruptures show the great diagnostic value of this method of examination. There are 6 types of clinical and x-ray syndromes to be distinguished: gaseous, hemorrhagic, compression, aspiration, ventilatory, perfusive. Both direct and indirect radiomorphological and radiofunctional features of the bronchial ruptures are distinguished. Post-traumatic bronchial stenoses, as well as the results of reconstructive interventions in bronchial ruptures and their consequences are discussed [ru

  6. Sacroiliitis in children with spondyloarthropathy: therapeutic effect of CT-guided intra-articular corticosteroid injection; Sakroiliitis bei Kinder mit Spondylarthropathie: Therapeutischer Effekt der CT-gestuetzten intraartikulaeren Kortikosteroid-Injektionen

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T.; Hermann, K.G.A.; Diekmann, F.; Hamm, B. [Humboldt-Universitaet, Berlin (Germany). Universitaetsklinikum Charite, Inst. fuer Radiologie; Biedermann, T. [HELIOS Klinikum Berlin (Germany). II. Klinik fuer Kinderheilkunde und Jugendmedizin, Abt. Kinderrheumatologie; Braun, J. [Rheumazentrum Ruhrgebiet, St. Josefs-Krankenhaus (Germany); Bollow, M. [Augusta-Krankenhaus, Bochum (Germany). Inst. fuer Radiologie

    2003-06-01

    Purpose: The prospective investigation of the therapeutic effect of CT-guided intra-articular corticosteroid injection into inflammatory sacroiliac (SI) joints compared to conventional treatment with nonsteroidal anti-inflammatory drugs (NSAIDS) in children with juvenile spondyloarthropathy (jSpA) and the determination of the role of dynamic magnetic resonance imaging (MRI) in establishing the indication and monitoring the therapy. Materials and Methods: The study comprises 89 children with known jSpA who were diagnosed by MRI to have a unilateral or bilateral sacroiliitis. Therapy with NSAIDS was initiated or continued in all 89 patients. Four weeks after the diagnostic MRI, two groups were distinguished according to the clinical response of NSAIDS, with group 1 consisting of 22 responders and group 2 of 56 non-responders. The patients of group 2 were treated with CT-guided intra-articular corticosteroid injection (low-dose injection) while the therapy with NSAIDS was continued. A total of 83 SI joints were punctured without complications, 27 bilaterally and 29 unilaterally. The indication for the intervention was based on inflammatory activity as determined by MRI. The therapy was monitored by clinical follow-up every 8 to 12 weeks over a period of 20 months. Follow-up by dynamic MRI was performed in all 56 children of group 2 and 15 of the 33 children of group 1 within 8{+-}4 months of the initial examination. Results: A total of 87.5% of the children in group 2 showed a statistically signficant decrease in their subjective complaints from 6.9{+-}3.4 to 1.8{+-}1.7 (p<0.05) as measured on a visual analog scale (VAS from 0 to 10). Improvement was seen as early as 1.5{+-}1.0 weeks after the intervention and lasted for a mean of 12{+-}6 months. The children in group 1 already showed similar improvement of the VAS from 6.8{+-}3.2 to 1.5{+-}1.4 (p<0.05) during the initial four weeks of NSAIDS therapy, with the improvement lasting for the 20-month observation period

  7. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  8. Blunt traumatic diaphragmatic rupture

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Nogueira

    2011-09-01

    Full Text Available Traumatic injury of the diaphragm ranges from 0.6 to 1.2% and rise up to 5%among patients who were victims of blunt trauma and underwent laparotomy.Clinical suspicion associated with radiological assessment contributes to earlydiagnosis. Isolated diaphragmatic injury has a good prognosis. Generallyworse outcomes are associated with other trauma injuries. Bilateral andright diaphragmatic lesions have worse prognosis. Multi detector computed tomography (MDCT scan of the chest and abdomen provides better diagnosticaccuracy using the possibility of image multiplanar reconstruction. Surgicalrepair via laparotomy and/ or thoracotomy in the acute phase of the injury hasa better outcome and avoids chronic complications of diaphragmatic hernia.The authors present the case of a young male patient, victim of blunt abdominaltrauma due to motor vehicle accident with rupture of the diaphragm, spleenand kidney injuries. The diagnosis was made by computed tomography of thethorax and abdomen and was confirmed during laparotomy.

  9. Tracker-on-C for cone-beam CT-guided surgery: evaluation of geometric accuracy and clinical applications

    Science.gov (United States)

    Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.

    2012-02-01

    -arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.

  10. Management of prelabor rupture of membranes at term. A randomized study

    DEFF Research Database (Denmark)

    Sperling, Lene; Schantz, A L; Wåhlin, A

    1993-01-01

    OBJECTIVE: To compare the rate of obstetric interventions, length of labor, and maternal morbidity in pregnancies with prelabor rupture of membranes at term after either early or late induction of labor in both primiparous and pluriparous women. DESIGN: Prospective, randomized study. SUBJECTS: 362...... primiparous and pluriparous (p rupture of membranes to delivery increased...

  11. Retrospective Review of Pectoralis Major Ruptures in Rodeo Steer Wrestlers

    Directory of Open Access Journals (Sweden)

    Breda H. F. Lau

    2013-01-01

    Full Text Available Background. Pectoralis major tendon ruptures have been reported in the literature as occupational injuries, accidental injuries, and sporting activities. Few cases have been reported with respect to rodeo activities. Purpose. To describe a series of PM tendon ruptures in professional steer wrestlers. Study Design. Case series, level of evidence, 4. Methods. A retrospective analysis of PM ruptures in a steer wrestling cohort was performed. Injury data between 1992 and 2008 were reviewed using medical records from the University of Calgary Sport Medicine Center. Results. Nine cases of pectoralis major ruptures in professional steer wrestlers were identified. Injuries occurred during the throwing phase of the steer or while breaking a fall. All athletes reported unexpected or abnormal behavior of the steer that contributed to the mechanism of injury. Seven cases were surgically repaired, while two cases opted for nonsurgical intervention. Eight cases reported successful return to competition following the injury. Conclusion. Steer wrestlers represent a unique cohort of PM rupture case studies. Steer wrestling is a demanding sport that involves throwing maneuvers that may predispose the muscle to rupture. All cases demonstrated good functional outcomes regardless of surgical or non-surgical treatment.

  12. Traumatic gastric rupture following blunt abdominal trauma: a case report about an atypical modality of presentation

    Directory of Open Access Journals (Sweden)

    Dario Giambelluca

    2017-04-01

    Full Text Available Gastric rupture following blunt abdominal trauma is a rare presentation with a reported incidence of 0.02-1.7% in current literature. Traumatic gastric rupture is usually associated with other visceral injuries, such as splenic lesions and fractures. Prompt diagnosis and early intervention reduce mortality and morbidity. History of a recent meal has been implicated in traumatic gastric rupture. We report a case of blunt abdominal trauma with an isolated gastric rupture after a motor vehicle accident, managed successfully without any post-operative morbidity and mortality.

  13. CT-Guided Microwave Ablation of 45 Renal Tumors: Analysis of Procedure Complexity Utilizing a Percutaneous Renal Ablation Complexity Scoring System.

    Science.gov (United States)

    Mansilla, Alberto V; Bivins, Eugene E; Contreras, Francisco; Hernandez, Manuel A; Kohler, Nathan; Pepe, Julie W

    2017-02-01

    To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors. Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30-89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2-4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor. Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9-46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ 2 = 12.073, df = 2, P = .002). The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  14. Performance of intra-procedural 18-fluorodeoxyglucose PET/CT-guided biopsies for lesions suspected of malignancy but poorly visualized with other modalities

    International Nuclear Information System (INIS)

    Cornelis, F.; Silk, M.; Takaki, H.; Durack, J.C.; Erinjeri, J.P.; Sofocleous, C.T.; Siegelbaum, R.H.; Maybody, M.; Solomon, S.B.; Schoder, H.

    2014-01-01

    We sought to evaluate the safety and the diagnostic success rate of percutaneous biopsies performed under intra-procedural 18 F-deoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) guidance for lesions difficult to see with conventional cross-sectional imaging. From 2011 to 2013, consecutive clinically indicated percutaneous PET/CT-guided biopsies of 106 masses (mean size, 3.3 cm; range, 0.7-15.9 cm; SD, 2.9 cm) in bones (n = 33), liver (n = 26), soft tissues (n = 18), lung (n = 15) and abdomen (n = 14) were reviewed. The biopsy procedures were performed following injection of a mean of 255 MBq (SD, 74) FDG. Mean maximal standardized uptake value (SUV) of lesions was 8.8 (SD, 6.3). A systematic review of the histopathological results and outcomes was performed. Biopsies were positive for malignancy in 76 cases (71.7 %, 76/106) and for benign tissue in 30 cases (28.3 %, 30/106). Immediate results were considered adequate for 100 PET/CT biopsies (94.3 %, 100/106) requiring no further exploration, and for the six others (5.7 %, 6/106) benign diagnoses were confirmed after surgery (n = 4) or follow-up (n = 2). The consequent overall sensitivity and the diagnostic success of biopsy were therefore 100 %. No significant differences in terms of detection of malignancy were observed between the different locations. Lesions > 2 cm or with SUV > 4 were not significantly more likely to be malignant. Complications occurred after four biopsies (3.7 %, 4/106). Intra-procedural PET/CT guidance appears as a safe and effective method and allows high diagnostic success of percutaneous biopsies for metabolically active lesions. (orig.)

  15. CT-guided {sup 125}I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei, E-mail: gaof@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Li, Chuanxing, E-mail: licx@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Gu, Yangkui, E-mail: guyk@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Huang, Jinhua, E-mail: huangjh@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Wu, Peihong, E-mail: vivian-link@163.com [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China)

    2013-02-15

    Objectives: To retrospectively evaluate effectiveness and safety of CT-guided {sup 125}I brachytherapy in 16 patients with mediastinal metastatic lymph nodes recurrence from esophageal carcinoma. Materials and methods: Sixteen metastatic lymph nodes in 16 patients were percutaneously treated in 19 {sup 125}I brachytherapy sessions. Each metastatic lymph node was treated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT or positron emission tomographic (PET) scans were reviewed and the treatment's effectiveness was evaluated. Results: Months are counted from the first time of {sup 125}I brachytherapy and the median duration of follow-up was 11 months (range, 5–16 months). The local control rates after 3, 6, 10 and 15 months were 75.0, 50.0, 42.9 and 33.3% respectively. At the time of writing, four patients are alive without evidence of recurrence at 16, 9, 16 and 9 months. The 4 patients presented good control of local tumor and no systemic recurrence, and survived throughout the follow-up period. The other 12 patients died of multiple hematogenous metastases 5–15 months after brachytherapy. A small amount of local hematoma occurred in 2 patients that involved applicator insertion through the lung. Two patients presented pneumothorax with pulmonary compression of 30 and 40% after the procedure and recovered after drainage. One patient had minor displacement of radioactive seeds. Severe complications such as massive bleeding and radiation pneumonitis did not occur. Conclusion: {sup 125}I radioactive seed implantation is effective and may be safely applied to mediastinal metastatic lymph nodes recurrence from esophageal carcinoma.

  16. Value of 18F-FDG PET/MRI for the outcome of CT-guided facet block therapy in cervical facet syndrome: initial results

    International Nuclear Information System (INIS)

    Sawixki, Lino M.; Schaarscjmidt, Benedikt M.; Heusch, Philipp; Buchbender, Christian; Antoch, Gerald; Rosenbaum-Krumme, Sandra; Bockisch, Andreas; Umutlu, Lale; Eicker, Sven O.; Floeth, Frank W.

    2017-01-01

    The aim of this study was to evaluate the ability of 18 F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ( 18 F-FDG PET/MRI) to detect PET-positive cervical facet arthropathy and identify patients who benefit from facet block therapy. Ten patients with cervical facet syndrome (mean age: 65 ± 12 years) underwent 18 F-FDG PET/MRI of the neck. Focal 18 F-FDG uptake in PET-positive facet joints served as target for computed tomography (CT)-guided facet blocks. In PET-negative patients, the target joint for facet block therapy was selected by current clinical standards considering the level of maximum facet arthrosis and pain. Neck pain was measured on visual analogue scale (VAS) before and after therapy. Bone marrow signal intensity (SI) ratio on turbo inversion recovery magnitude (TIRM) images and maximum standard uptake values (SUVmax) was calculated for each facet joint. Pearson's correlation coefficient (r) was calculated between bone marrow SI ratios on TIRM and SUVmax. 18 F-FDG PET/MRI detected PET-positive facet arthropathy in six patients. Patients with PET-positive facet arthropathy had significantly less pain compared with the pretreatment pain 3 h (P = 0.002), 4 weeks (P = 0.002) and 3 months (P = 0.026) after facet block therapy. Pain did not change significantly in patients with PET-negative facet arthropathy. TIRM SI ratio was higher in PET-positive facet arthropathy than in PET-negative facet arthropathy (P < 0.001). Correlation was strong between bone marrow SI ratio on TIRM images and SUVmax (r = 0.7; P < 0.001).

  17. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  18. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  19. The diagnosis of breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse; Conrad, Carsten

    2005-01-01

    participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture...... were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89...

  20. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  1. Ruptured Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Valentina Park

    2016-09-01

    Full Text Available History of present illness: A 21-year-old female presented with sudden onset suprapubic abdominal pain associated with dysuria. The patient also experienced near syncope during bowel movements three times three days ago without falling or losing consciousness. She denied fever, nausea, and vomiting. She stated that she was five weeks pregnant by last menstrual period. She had an ultrasound a few weeks before that showed no intrauterine pregnancy, but she had not followed up for additional testing. Significant findings: The patient’s serum beta-hCG was 5,637 mIU/mL. The transvaginal ultrasound showed an empty uterus with free fluid posteriorly in the pelvis and Pouch of Douglas (00:00. A 4.5 cm heterogeneous mass was visible in the left adnexa concerning for an ectopic pregnancy (00:10. Discussion: Ectopic pregnancies are a leading cause of maternal morbidity and mortality, as well as decreased fertility.1,2 Differentiating between an ectopic pregnancy and a normal early pregnancy may be difficult, since ultrasound and quantitative beta-hCG may show inconclusive results.3,4 Patients who have used fertility treatment may further complicate the picture because they are at risk for heterotypic pregnancies.5 Ectopic pregnancies most commonly implant in the fallopian tube, but may alternatively implant in the ovary, cervix, abdomen, or uterine cornua.4 Ultrasonography may show an empty uterus, adnexal mass, pelvic free fluid, or an extra-uterine gestational sac, yolk sac, and/or embryo.6 Treatment options for ectopic pregnancy include surgery or methotrexate.2,4 Some patients may be candidates for close outpatient surveillance if the diagnosis is unclear or in very limited cases for early, non-ruptured ectopic pregnancies.2,4

  2. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive: the APACH1 study.

    Science.gov (United States)

    Quak, Elske; Blanchard, David; Houdu, Benjamin; Le Roux, Yannick; Ciappuccini, Renaud; Lireux, Barbara; de Raucourt, Dominique; Grellard, Jean-Michel; Licaj, Idlir; Bardet, Stéphane; Reznik, Yves; Clarisse, Bénédicte; Aide, Nicolas

    2018-04-01

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients

  3. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive. The APACH1 study

    Energy Technology Data Exchange (ETDEWEB)

    Quak, Elske; Lireux, Barbara; Bardet, Stephane [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); Blanchard, David; Raucourt, Dominique de [Francois Baclesse Cancer Centre, Department of Head and Neck Surgery, Caen (France); Houdu, Benjamin [University Hospital, Department of Nuclear Medicine, Caen (France); Le Roux, Yannick [University Hospital, Department of General and Endocrine Surgery, Caen (France); Ciappuccini, Renaud [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); Caen University, INSERM 1086 ANTICIPE, Caen (France); Grellard, Jean-Michel; Licaj, Idlir; Clarisse, Benedicte [Francois Baclesse Cancer Centre, Department of Clinical Research, Caen (France); Reznik, Yves [University Hospital, Department of Endocrinology, Caen (France); Aide, Nicolas [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); University Hospital, Department of Nuclear Medicine, Caen (France); Caen University, INSERM 1086 ANTICIPE, Caen (France)

    2018-04-15

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary

  4. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

    Science.gov (United States)

    Bowen, S R; Nyflot, M J; Herrmann, C; Groh, C M; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-05-07

    of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.

  5. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    International Nuclear Information System (INIS)

    Bowen, S R; Nyflot, M J; Meyer, J; Sandison, G A; Herrmann, C; Groh, C M; Wollenweber, S D; Stearns, C W; Kinahan, P E

    2015-01-01

    planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery. (paper)

  6. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    Science.gov (United States)

    Bowen, S R; Nyflot, M J; Hermann, C; Groh, C; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-01-01

    magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery. PMID:25884892

  7. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive. The APACH1 study

    International Nuclear Information System (INIS)

    Quak, Elske; Lireux, Barbara; Bardet, Stephane; Blanchard, David; Raucourt, Dominique de; Houdu, Benjamin; Le Roux, Yannick; Ciappuccini, Renaud; Grellard, Jean-Michel; Licaj, Idlir; Clarisse, Benedicte; Reznik, Yves; Aide, Nicolas

    2018-01-01

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary

  8. A Case of Ruptured Splenic Artery Aneurysm in Pregnancy

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Corey

    2014-01-01

    Full Text Available Background. Rupture of a splenic artery aneurysm is rare complication of pregnancy that is associated with a significant maternal and fetal mortality. Case. A multiparous female presented in the third trimester with hypotension, tachycardia, and altered mental status. A ruptured splenic artery aneurysm was discovered at the time of laparotomy and cesarean delivery. The patient made a full recovery following resection of the aneurysm. The neonate survived but suffered severe neurologic impairment. Conclusion. The diagnosis of ruptured splenic artery aneurysm should be considered in a pregnant woman presenting with signs of intra-abdominal hemorrhage. Early intervention by a multidisciplinary surgical team is key to preserving the life of the mother and fetus.

  9. Transcervical intrapartum amnioinfusion for preterm premature rupture of the membranes.

    Science.gov (United States)

    Puertas, Alberto; Tirado, Pilar; Pérez, Isabel; López, María S; Montoya, Francisco; Cañizares, José M; Miranda, José A

    2007-03-01

    To investigate the effect of transcervical amnioinfusion on the management of labour and neonatal outcomes in preterm premature rupture of the membranes. This clinical trial included 86 patients with premature rupture of the membranes between weeks 27 and 35 of gestation. Patients were randomly assigned to receive amnioinfusion via a two-way catheter or to the control group. Clinical management was otherwise the same in both groups. Amnioinfusion decreased the frequency of variable decelerations in fetal heart rate (27.9% versus 53.5%, pamnioinfusion for preterm premature rupture of the membranes reduced the number of interventions needed because of nonreassuring fetal status, and improved neonatal gasometric values without increasing maternal or fetal morbidity.

  10. A Case of Post Myocardial Infarction Papillary Muscle Rupture.

    Science.gov (United States)

    Anuwatworn, Amornpol; Milnes, Christopher; Kumar, Vishesh; Raizada, Amol; Nykamp, Verlyn; Stys, Adam

    2016-06-01

    Papillary muscle rupture is a rare, life-threatening post myocardial infarction mechanical complication. Without surgical intervention, prognosis is very poor. Clinicians need to recognize this complication early, as prompt therapy is crucial. We present a case of inferior ST elevation myocardial infarction complicated by posteromedial papillary muscle rupture resulting in severe acute mitral regurgitation (flail anterior mitral leaflet), acute pulmonary edema and cardiogenic shock. In our patient, a new mitral regurgitation murmur suggested this mechanical complication. Complete disruption of papillary muscle was visualized by transesophageal echocardiography. This case illustrates the importance of good physical examination for early diagnosis of papillary muscle rupture, so that life-saving treatment can be administered without delay.

  11. Incidence of delayed complications following percutaneous CT-guided biopsy of bone and soft tissue lesions of the spine and extremities: A 2-year prospective study and analysis of risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Rosenthal, Daniel I. [Massachusetts General Hospital, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute of Technology Assessment, Boston, MA (United States)

    2013-01-15

    To prospectively evaluate the incidence of delayed complications (bleeding, pain, infection) following CT-guided biopsies of bone or soft tissue lesions and to identify risk factors that predispose to their occurrence. All adults presenting for CT-guided biopsy of a bone or soft tissue lesion were eligible for the study. Risk factors considered included patient gender and age, bone versus soft tissue, lesion location, lesion depth, anticoagulation, conscious sedation, coaxial biopsy technique, bleeding during the biopsy, dressing type and duration of placement, final diagnosis, needle gauge, number of passes, and number of days to follow-up. Outcomes measured included fever, pain, bruising/hematoma formation, and swelling and were collected by a follow-up phone call within 14 days of the biopsy. Fisher's exact test, the Wald Chi-square test, and univariate, multivariate, and stepwise logistic regression were performed to evaluate the influence of the risk factors on the outcomes. A total of 386 patients participated in the study. The rates of post-biopsy fever, pain, bruising, and swelling were 1.0, 16.1, 15.6, and 9.6 %, respectively. Anticoagulants were identified as a risk factor for fever. Increasing patient age was identified as a risk factor for pain. Female gender and lesion location were identified as risk factors for bruising. Increasing patient age and lesion location were identified as risk factors for swelling. Patient age, female gender, and lesion location are risk factors for delayed minor complications following CT-guided biopsy of a bone or soft tissue lesion. There were no major complications. None of the complications in this series altered patient management. (orig.)

  12. Incidence of delayed complications following percutaneous CT-guided biopsy of bone and soft tissue lesions of the spine and extremities: A 2-year prospective study and analysis of risk factors

    International Nuclear Information System (INIS)

    Huang, Ambrose J.; Rosenthal, Daniel I.; Halpern, Elkan F.

    2013-01-01

    To prospectively evaluate the incidence of delayed complications (bleeding, pain, infection) following CT-guided biopsies of bone or soft tissue lesions and to identify risk factors that predispose to their occurrence. All adults presenting for CT-guided biopsy of a bone or soft tissue lesion were eligible for the study. Risk factors considered included patient gender and age, bone versus soft tissue, lesion location, lesion depth, anticoagulation, conscious sedation, coaxial biopsy technique, bleeding during the biopsy, dressing type and duration of placement, final diagnosis, needle gauge, number of passes, and number of days to follow-up. Outcomes measured included fever, pain, bruising/hematoma formation, and swelling and were collected by a follow-up phone call within 14 days of the biopsy. Fisher's exact test, the Wald Chi-square test, and univariate, multivariate, and stepwise logistic regression were performed to evaluate the influence of the risk factors on the outcomes. A total of 386 patients participated in the study. The rates of post-biopsy fever, pain, bruising, and swelling were 1.0, 16.1, 15.6, and 9.6 %, respectively. Anticoagulants were identified as a risk factor for fever. Increasing patient age was identified as a risk factor for pain. Female gender and lesion location were identified as risk factors for bruising. Increasing patient age and lesion location were identified as risk factors for swelling. Patient age, female gender, and lesion location are risk factors for delayed minor complications following CT-guided biopsy of a bone or soft tissue lesion. There were no major complications. None of the complications in this series altered patient management. (orig.)

  13. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.

    Science.gov (United States)

    Nour-Eldin, Nour-Eldin A; Alsubhi, Mohammed; Emam, Ahmed; Lehnert, Thomas; Beeres, Martin; Jacobi, Volkmar; Gruber-Rouh, Tatjana; Scholtz, Jan-Erik; Vogl, Thomas J; Naguib, Nagy N

    2016-02-01

    To assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management. The study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann-Whitney U test and Fisher's exact tests were used for statistical analysis. p values pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7

  14. Physics of Earthquake Rupture Propagation

    Science.gov (United States)

    Xu, Shiqing; Fukuyama, Eiichi; Sagy, Amir; Doan, Mai-Linh

    2018-05-01

    A comprehensive understanding of earthquake rupture propagation requires the study of not only the sudden release of elastic strain energy during co-seismic slip, but also of other processes that operate at a variety of spatiotemporal scales. For example, the accumulation of the elastic strain energy usually takes decades to hundreds of years, and rupture propagation and termination modify the bulk properties of the surrounding medium that can influence the behavior of future earthquakes. To share recent findings in the multiscale investigation of earthquake rupture propagation, we held a session entitled "Physics of Earthquake Rupture Propagation" during the 2016 American Geophysical Union (AGU) Fall Meeting in San Francisco. The session included 46 poster and 32 oral presentations, reporting observations of natural earthquakes, numerical and experimental simulations of earthquake ruptures, and studies of earthquake fault friction. These presentations and discussions during and after the session suggested a need to document more formally the research findings, particularly new observations and views different from conventional ones, complexities in fault zone properties and loading conditions, the diversity of fault slip modes and their interactions, the evaluation of observational and model uncertainties, and comparison between empirical and physics-based models. Therefore, we organize this Special Issue (SI) of Tectonophysics under the same title as our AGU session, hoping to inspire future investigations. Eighteen articles (marked with "this issue") are included in this SI and grouped into the following six categories.

  15. Assessing the potential risk of rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Khan, S.; Verma, V.; Verma, S.; Polzer, S.; Jha, S.

    2015-01-01

    Abdominal aortic aneurysms (AAAs) involve complex interplays between inflammatory and biomechanical factors that can be elucidated with anatomical and functional imaging. Although AAA size has been well-established in the literature to correlate with risk of rupture (and subsequent need for vascular intervention), there are other less-well-known characteristics about AAAs that also contribute to higher risk of rupture. This review focuses on biomechanical, radiological, and epidemiological characteristics of AAAs that are associated with higher rupture risk. For clinicians, knowing and considering a wide variety of risk factors in addition to AAA size is important to initiate early and proper intervention for AAA repair. Although there is no official quantitative risk score of AAA rupture risk that takes other non-size-related variables into account, if clinicians are aware of these other parameters, it is hoped that intervention can be appropriately performed for higher-risk AAAs that have not met the size-threshold for elective repair

  16. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  17. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  18. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  19. Rupture luminescence from natural fibers

    Science.gov (United States)

    Li, W.; Haneman, D.

    1999-12-01

    Fibers of cotton and wool, and samples of paper, have been ruptured in tension in vacuum and in air, and give detectable luminescence in the visible range. All have a common emission peak at around 2.0 eV, which is ascribed to the deexcitation of states excited by the rupture of organic chain molecule bonds. Rubber bands give stronger emission in air, but no emission in vacuum, suggesting the material breaks only at weak interchain bonds. Mohair, cat, and horse hair also give emission in air. The phenomena reveal effects that would occur widely in nature.

  20. Atherosclerotic plaque rupture and thrombosis. Evolving concepts.

    Science.gov (United States)

    Fuster, V; Stein, B; Ambrose, J A; Badimon, L; Badimon, J J; Chesebro, J H

    1990-09-01

    Rupture of an atherosclerotic plaque associated with partial or complete thrombotic vessel occlusion is fundamental to the development of ischemic coronary syndromes. Plaques that produce only mild-to-moderate angiographic luminal stenosis are frequently those that undergo abrupt disruption, leading to unstable angina or acute myocardial infarction. Plaques with increased lipid content appear more prone to rupture, particularly when the lipid pool is localized eccentrically within the intima. Macrophages appear to play an important role in atherogenesis, perhaps by participating in the uptake and metabolism of lipoproteins, secretion of growth factors, and production of enzymes and toxic metabolites that may facilitate plaque rupture. In addition, the particular composition or configuration of a plaque and the hemodynamic forces to which it is exposed may determine its susceptibility to disruption. Exposure of collagen, lipids, and smooth muscle cells after plaque rupture leads to the activation of platelets and the coagulation cascade system. The resulting thrombus may lead to marked reduction in myocardial perfusion and the development of an unstable coronary syndrome, or it may become organized and incorporated into the diseased vessel, thus contributing to the progression of atherosclerosis. In unstable angina, plaque disruption leads to thrombosis, which is usually labile and results in only a transient reduction in myocardial perfusion. Release of vasoactive substances, arterial spasm, or increases in myocardial oxygen demand may contribute to ischemia. In acute myocardial infarction, plaque disruption results in a more persistent thrombotic vessel occlusion; the extent of necrosis depends on the size of the artery, the duration of occlusion, the presence of collateral flow, and the integrity of the fibrinolytic system. Thrombi that undergo lysis expose a highly thrombogenic surface to the circulating blood, which has the capacity of activating platelets and

  1. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  2. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  3. PREMATURE RUPTURE OF THE MEMBRANES*

    African Journals Online (AJOL)

    In patients presenting with premature rupture of the membranes there are two factors which influence the foetal morbidity and mortality. These factors are prema- turity and intra-uterine infection. The purpose of this analysis was to elucidate which factor carried the greater risk to the foetus. Recently there has been a spate of.

  4. Ruptured Cervical Anellrysm with Neurofibromatosis

    African Journals Online (AJOL)

    rupture of an aneurysm of a lateral branch of the right thyrocervical trunk in a patient suffering from diffuse neurofibromatosis. The operative findings are reported. s. Air. Med. ... system demonstrated decreased power in all muscles of the right shoulder girdle and arm, without sensory change. The cranial nerves were normal.

  5. Spontaneous Splenic Rupture in Melanoma

    Directory of Open Access Journals (Sweden)

    Hadi Mirfazaelian

    2014-01-01

    Full Text Available Spontaneous rupture of spleen due to malignant melanoma is a rare situation, with only a few case reports in the literature. This study reports a previously healthy, 30-year-old man who came with chief complaint of acute abdominal pain to emergency room. On physical examination, abdominal tenderness and guarding were detected to be coincident with hypotension. Ultrasonography revealed mild splenomegaly with moderate free fluid in abdominopelvic cavity. Considering acute abdominal pain and hemodynamic instability, he underwent splenectomy with splenic rupture as the source of bleeding. Histologic examination showed diffuse infiltration by tumor. Immunohistochemical study (positive for S100, HMB45, and vimentin and negative for CK, CD10, CK20, CK7, CD30, LCA, EMA, and chromogranin confirmed metastatic malignant melanoma. On further questioning, there was a past history of a nasal dark skin lesion which was removed two years ago with no pathologic examination. Spontaneous (nontraumatic rupture of spleen is an uncommon situation and it happens very rarely due to neoplastic metastasis. Metastasis of malignant melanoma is one of the rare causes of the spontaneous rupture of spleen.

  6. Endometriosis-related spontaneous diaphragmatic rupture.

    Science.gov (United States)

    Triponez, Frédéric; Alifano, Marco; Bobbio, Antonio; Regnard, Jean-François

    2010-10-01

    Non-traumatic, spontaneous diaphragmatic rupture is a rare event whose pathophysiology is not known. We report the case of endometriosis-related spontaneous rupture of the right diaphragm with intrathoracic herniation of the liver, gallbladder and colon. We hypothesize that the invasiveness of endometriotic tissue caused diaphragm fragility, which finally lead to its complete rupture without traumatic event. The treatment consisted of a classical management of diaphragmatic rupture, with excision of the endometriotic nodule followed by medical ovarian suppression for six months.

  7. ACL Rupture in Collegiate Wrestler

    Directory of Open Access Journals (Sweden)

    Lindsay A. Palmer

    2016-05-01

    Full Text Available Objective: To educate others on unique Anterior Cruciate Ligament tears and percentage of usage of the ACL in normal daily function. Background: Patient is an eighteen year old male participating in wrestling and football at the time of the injury. Patient now only participates in wrestling. No previous knee or chronic injuries were reported prior to this injury. Patient was playing football during the time of injury. The patient stated that he planted his foot down and was tackled at the same time when the injury occurred. The patient felt his knee twist and buckle. Patient complained of clicking inside the knee and had minimal swelling. He also complained of it being difficult to bear weight at the time. The patient did not seek further treatment until two months after the injury occurred when he received an MRI. His MRI showed a positive finding for an Anterior Cruciate Ligament rupture. His previous Athletic Trainer could not find a positive diagnosis for the patient prior to the MRI. Differential Diagnosis: Possible meniscal or ACL injury. Treatment: Doctors officially diagnosed the injury as a complete rupture of the ACL. The patient did not receive surgery immediately. Doctors have stated that he only uses about 50% of his ACL on a daily basis compared to a normal person who uses about 95% of their ACL daily. Because of this, the patient played on his rupture for seven months before receiving surgery. He played a whole season of high school football and a whole season of wrestling his senior year with the ACL ruptured. The patient only used a brace for better comfort during the seven months. The patient then received reconstructive surgery to repair the rupture. A hamstring tendon graft was used to repair the ruptured ACL. Because a tendon was taken from the hamstring, patient experienced a tight ACL and hamstring of the left leg post-surgery. The patient participated in Physical Therapy for five months to strengthen and stretch the new

  8. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  9. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  10. Importance of CT Imaging on Spontaneous Rupture of Renal Angiomyolipoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Fatma Gundogdu

    2016-02-01

    Full Text Available Renal angiomyolipomas have a high risk of rupture when they are large and associated with aneurysms. The most serious complication that may occur is life-threatening intratumoral bleeding. Immediate interventional therapies to stop bleeding are required. Herein, we report on a 16-year-old female patient with a retroperitoneal hematoma due to a spontaneous renal angiomyolipoma rupture by computed tomography.

  11. Preterm Delivery in the Setting of Left Calyceal Rupture

    Directory of Open Access Journals (Sweden)

    Brent Hanson

    2015-01-01

    Full Text Available Spontaneous rupture of the renal collecting system is a rare but serious complication of pregnancy. We report a case of nontraumatic left renal calyceal rupture in a pregnancy which ultimately progressed to preterm delivery. A 29-year-old primigravida with a remote history of urolithiasis presented with left flank pain, suprapubic pain, and signs of preterm labor at 33 weeks of gestation. The patient was believed to have urolithiasis, although initial renal ultrasound failed to demonstrate definitive calculi. After a temporary improvement in flank pain with medication, the patient experienced acute worsening of her left flank pain. Urology was consulted and further imaging was obtained. Magnetic resonance imaging (MRI was consistent with bilateral hydronephrosis and rupture of the left renal calyx. Given the patient’s worsening pain in the setting of left calyceal rupture, the urology team planned for placement of a left ureteral stent. However, before the patient could receive her stent, she progressed to active labor and delivered a viable female infant vaginally. Following delivery, the patient’s flank pain resolved rapidly and spontaneously, so no surgical intervention was performed. A summary of the literature and the details of this specific clinical situation are provided.

  12. Renal allograft rupture: US diagnosis

    International Nuclear Information System (INIS)

    Maklad, N.F.

    1987-01-01

    The US appearances in seven pathologically and/or surgically proved cases of renal allograft rupture are presented. These include a triangular or amorphous echogenic area in the cortex and medulla in a polar location, an echogenic band or wavy, branching anechoic lines in the hyperechoic region, a subcapsular hematoma, and an extrarenal hematoma in direct continuity with the echogenic area. Duplex Doppler examination in renal allograft rupture shows marked reduction of absence of the diastolic component of the velocity waveform in the arcuate and interlobar arteries, with reduction in amplitude of the systolic wave form. Correlation of the US appearances with gross and microscopic pathologic findings indicates that the echogenic area is due to an intrarenal hematoma, while the echogenic band represents the cortical laceration with adherent blood clots. The US-duplex Doppler examination should be the primary diagnostic modality in this life-threatening condition

  13. Achilles tendon rupture in badminton.

    Science.gov (United States)

    Kaalund, S; Lass, P; Høgsaa, B; Nøhr, M

    1989-01-01

    The typical badminton player with an Achilles tendon rupture is 36 years old and, despite limbering up, is injured at the rear line in a sudden forward movement. He resumes work within three months and has a slight lack of dorsiflexion in the ankle as the main complication. Most patients resume badminton within one year, but some finish their sports career, mainly due to fear of a new injury. The investigation discusses predisposing factors and prophylactic measures. PMID:2605439

  14. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com; Alsubhi, Mohammed, E-mail: mohammedal-subhi@yahoo.com; Emam, Ahmed, E-mail: morgan101002@hotmail.com; Lehnert, Thomas, E-mail: thomas.lehnert@kgu.de; Beeres, Martin, E-mail: beeres@gmx.net; Jacobi, Volkmar, E-mail: volkmar.jacobi@kgu.de; Gruber-Rouh, Tatjana, E-mail: tatjanagruber2004@yahoo.com; Scholtz, Jan-Erik, E-mail: janerikscholtz@gmail.com; Vogl, Thomas J., E-mail: t.vogl@em.uni-frankfurt.de; Naguib, Nagy N., E-mail: nagynnn@yahoo.com [Johan Wolfgang Goethe – University Hospital, Institute for Diagnostic and Interventional Radiology (Germany)

    2016-02-15

    PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both

  15. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

    International Nuclear Information System (INIS)

    Nour-Eldin, Nour-Eldin A.; Alsubhi, Mohammed; Emam, Ahmed; Lehnert, Thomas; Beeres, Martin; Jacobi, Volkmar; Gruber-Rouh, Tatjana; Scholtz, Jan-Erik; Vogl, Thomas J.; Naguib, Nagy N.

    2016-01-01

    PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both

  16. CT-guided core biopsy and percutaneous fiducial seed placement in the lung: Can these procedures be combined without an increase in complication rate or decrease in technical success?

    Energy Technology Data Exchange (ETDEWEB)

    Mendiratta-Lala, Mishal [Henry Ford Hospital, Department of Radiology, Abdominal Interventional Radiology, 2799 West Grand Blvd, Detroit, MI 48202 (United States); Sheiman, Robert, E-mail: rsheiman@bidmc.harvard.edu [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Brook, Olga R. [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Gourtsoyianni, Sofia [King' s College London, St Thomas’ Hospital, Lambeth Palace Road, SE1 7EH London (United Kingdom); Mahadevan, Anand [Beth Israel Deaconess Hospital, Radiation Oncology, One Deaconess Road, Boston, MA 02215 (United States); Siewert, Bettina [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States)

    2014-04-15

    Objective: To determine if concomitant CT-guided biopsy and percutaneous fiducial seed placement in the lung can be performed in a selective patient population without increased complication or decreased success rates compared to either procedure alone. Materials and methods: An IRB approved retrospective analysis of 285 consecutive patients that underwent CT-guided placement of fiducial seeds in the lung alone (N = 63), with concomitant core biopsy (N = 53) or only core biopsy (N = 169) was performed. Variables compared included: patient demographics, lesion size, depth from pleura, needle size, number of passes through pleura, number and size of core biopsies, number of seeds placed and technical success rates. Statistical analysis was performed using univariate and multivariate pair-wise comparisons. Results: A pathologic diagnosis of malignancy was confirmed in all cases undergoing seed placement alone and seed placement with concurrent biopsy, and in 144 of the biopsy alone lesions. On univariate analysis, major complication rates were similar for all three groups as were lesion size, depth, number of pleural passes, and technical success. Pair-wise comparisons of the remaining variables demonstrated a significant younger age and smaller needle size in the biopsy only group, and less minor complications in the fiducial only group. Overall there were 80/285 (28.1%) minor and 29/285 (10.2%) major complications. All major complications leading to admission consisted of either pneumothorax or hemothorax, while minor complications included asymptomatic stable or resolving pneumothoraces, transient hemoptysis or small hemothoraces. Conclusions: A combined procedure of percutaneous pulmonary core biopsy and stereotactic seed placement can be performed without additional risk of a major complication when compared to performing these separately.

  17. Management of Hepatic Rupture Diagnosed after an Emergency Cesarean Section

    Directory of Open Access Journals (Sweden)

    Gianluca Raffaello Damiani

    2014-01-01

    Full Text Available A careful management of hepatic capsular rupture, with massive hemoperitoneum which occurred 14 hours after an emergency cesarean section at 36 weeks of gestation, is meticulously reported. The grade of hepatic involvement varies from minor capsular laceration to extensive parenchymal rupture. Our management involved a combination of surgical interventions and aggressive supportive care. The patient was discharged after 53 days and 4 laparotomies and an unsuccessful attempt of superselective artery embolization. Ultrasound after 40 days from the last surgery showed uniform hepatic parenchyma free of focal lesions. Due to the rarity and the unpredictability nature of this devastating event we believe necessary to report our experience, reinforcing the importance of the postsurgery management.

  18. Percutaneous transgluteal drainage of pelvic abscesses in interventional radiology: A safe alternative to surgery.

    Science.gov (United States)

    Robert, B; Chivot, C; Rebibo, L; Sabbagh, C; Regimbeau, J-M; Yzet, T

    2016-02-01

    Interventional radiology plays an important role in the management of deep pelvic abscesses. Percutaneous drainage is currently considered as the first-line alternative to surgery. A transgluteal computed tomography (CT)-guided approach allows to access to deep infected collections avoiding many anatomical obstacles (vessels, nerves, bowel, bladder). The objective of this study was to assess the safety and efficacy of a transgluteal approach by reviewing our clinical experience. We reviewed medical records of patients having undergone percutaneous CT-guided transgluteal drainage for deep pelvic abscesses. We focused on the duration of catheter drainage, the complications related to the procedures and the rate of complete resolution. Between 2005 and 2013, 39patients (27women and 12men; mean age: 52.5) underwent transgluteal approach CT-guided percutaneous drainage of pelvis abscesses in our department. The origins of abscesses were postoperative complications in 34patients (87.2%) and infectious intra-abdominal disease in 5patients (12.8%). The mean duration of drainage was 8.3days (range: 3-33). Laboratory cultures were positive in 35patients (89.7%) and Escherichia coli was present in 71.4% of the positive samples. No major complication was observed. Drainage was successful in 38patients (97.4%). A transpiriformis approach was more significantly associated with intra-procedural pain (P=0.003). Percutaneous CT-guided drainage with a transgluteal approach is a safe, well-tolerated and effective alternative to surgery for deep pelvic abscesses. This approach should be considered as the first-line intention for the treatment of deep pelvic abscesses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Neck curve polynomials in neck rupture model

    International Nuclear Information System (INIS)

    Kurniadi, Rizal; Perkasa, Yudha S.; Waris, Abdul

    2012-01-01

    The Neck Rupture Model is a model that explains the scission process which has smallest radius in liquid drop at certain position. Old fashion of rupture position is determined randomly so that has been called as Random Neck Rupture Model (RNRM). The neck curve polynomials have been employed in the Neck Rupture Model for calculation the fission yield of neutron induced fission reaction of 280 X 90 with changing of order of polynomials as well as temperature. The neck curve polynomials approximation shows the important effects in shaping of fission yield curve.

  20. Acute Pectoralis Major Rupture Captured on Video

    Directory of Open Access Journals (Sweden)

    Alejandro Ordas Bayon

    2016-01-01

    Full Text Available Pectoralis major (PM ruptures are uncommon injuries, although they are becoming more frequent. We report a case of a PM rupture in a young male who presented with axillar pain and absence of the anterior axillary fold after he perceived a snap while lifting 200 kg in the bench press. Diagnosis of PM rupture was suspected clinically and confirmed with imaging studies. The patient was treated surgically, reinserting the tendon to the humerus with suture anchors. One-year follow-up showed excellent results. The patient was recording his training on video, so we can observe in detail the most common mechanism of injury of PM rupture.

  1. Traumatic rupture of an intracranial dermoid cyst

    Directory of Open Access Journals (Sweden)

    Raksha Ramlakhan, BMedSc, MBBCh

    2015-01-01

    Full Text Available Intracranial dermoid cysts are congenital tumors of ectodermal origin. Rupture of these cysts can occur spontaneously, but rupture in association with trauma is reported infrequently. The diagnosis of rupture is made by the presence of lipid (cholesterol droplets in the subarachnoid spaces and ventricles. Nonenhanced CT of the head demonstrates multiple foci of low attenuation that correspond with hyperintense signal on T1-weighted MRI. We present a case of an adult patient with rupture of an intracranial dermoid cyst, precipitated by minor trauma.

  2. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  3. Ruptured corpus luteal cyst: Prediction of clinical outcomes with CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok; Moon, Min Hoan; Woo, Hyun Sik; Sung, Chang Kyu; Jeon, Hye Won; Lee, Taek Sang [SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    To evaluate the determinant pretreatment CT findings that can predict surgical intervention for patients suffering from corpus luteal cyst rupture with hemoperitoneum. From January 2009 to December 2014, a total of 106 female patients (mean age, 26.1 years; range, 17–44 years) who visited the emergency room of our institute for acute abdominal pain and were subsequently diagnosed with ruptured corpus luteal cyst with hemoperitoneum were included in the retrospective study. The analysis of CT findings included cyst size, cyst shape, sentinel clot sign, ring of fire sign, hemoperitoneum depth, active bleeding in portal phase and attenuation of hemoperitoneum. The comparison of CT findings between the surgery and conservative management groups was performed with the Mann-Whitney U test or chi-square test. Logistic regression analysis was used to determine significant CT findings in predicting surgical intervention for a ruptured cyst. Comparative analysis revealed that the presence of active bleeding and the hemoperitoneum depth were significantly different between the surgery and conservative management groups and were confirmed as significant CT findings for predicting surgery, with adjusted odds ratio (ORs) of 3.773 and 1.318, respectively (p < 0.01). On the receiver-operating characteristic curve analysis for hemoperitoneum depth, the optimal cut-off value was 5.8 cm with 73.7% sensitivity and 58.6% specificity (Az = 0.711, p = 0.004). In cases with a hemoperitoneum depth > 5.8 cm and concurrent active bleeding, the OR for surgery increased to 5.786. The presence of active bleeding and the hemoperitoneum depth on a pretreatment CT scan can be predictive warning signs of surgery for a patient with a ruptured corpus luteal cyst with hemoperitoneum.

  4. Spontaneous and traumatic hepatic rupture: imaging findings and minimally invasive treatment

    International Nuclear Information System (INIS)

    Palacio, Glaucia Andrade e Silva; D'Ippolito, Giuseppe

    2003-01-01

    Spontaneous hepatic bleeding is a rare condition. Our aim was to describe the imaging findings and minimally invasive treatment using transcatheter arterial embolization in patients with spontaneous and traumatic hepatic rupture. Three patients presented acute hemoperitoneum dur to hepatic rupture caused by spontaneous rupture of hepatocellular carcinoma, HELLP syndrome and a blunt hepatic trauma. The patients were submitted to ultrasound and computed tomography of the abdomen and subsequently treated by transcatheter arterial embolization. All patients underwent helical computed tomography before and after treatments. Computed tomography played an important role in the evaluation and follow-up in the therapeutic intervention. Different types of liver injuries were identified. Transcatheter arterial embolization blocked arterial hemorrhage in the patients who were hemodynamically unstable. The conclusion was: transcatheter arterial embolization is an effective and well-tolerated treatment method for the management of hepatic rupture and computed tomography is an excellent method for the diagnosis and follow-up of these patients. (author)

  5. Case report: spontaneous rupture of spleen in patient with Plasmodium ovale malaria.

    Science.gov (United States)

    Lemmerer, Raphael; Unger, Manuel; Voßen, Matthias; Forstner, Christina; Jalili, Ahmad; Starzengruber, Peter; Werzowa, Johannes; Ramharter, Michael; Winkler, Stefan; Thalhammer, Florian

    2016-01-01

    Malaria may lead to spontaneous splenic rupture as a rare but potentially lethal complication. Most frequently, this has been reported in patients infected with Plasmodium falciparum and Plasmodium vivax, while other parasitic agents are less likely to be the cause.We report a 29-year-old British Caucasian, who after returning from a business trip in Democratic Republic Congo was diagnosed with tertian malaria caused by Plasmodium ovale.During his in-patient stay, the patient suffered a splenic rupture requiring immediate surgical intervention and splenectomy. Following this surgical intervention, there was an uneventful recovery, and the patient was discharged in a good general condition.

  6. Long-term outcomes of percutaneous lumbar facet synovial cyst rupture

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Bos, Stijn A.; Torriani, Martin; Simeone, F.J.; Chang, Connie Y.; Pomerantz, Stuart R.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-01-15

    To evaluate the therapeutic value, safety, and long-term clinical outcomes of percutaneous lumbar facet synovial cyst (LFSC) rupture. Our study was institutional review board (IRB)-approved and Health Insurance Portability and Accountability Act (HIPAA)-compliant. The study group comprised 71 patients (44 women, mean age: 65 ± 17 years) who underwent CT- or fluoroscopy-guided percutaneous LFSC rupture. The technical success of LFSC rupture, the long-term clinical outcome, including repeat procedures or surgery, and imaging findings on MRI and CT were recorded. Seventy-nine LFSC ruptures were performed in 71 patients. CT guidance was used in 57 cases and fluoroscopy guidance in 22 cases. LFSC rupture was technically successful in 58 out of 79 cases (73 %). Mean injection volume for cyst rupture was 3.6 ± 2.2 mL and a combination of steroid and anesthetic was injected in all cases. Over a mean follow-up time of 44 months, 12 % of patients underwent repeat cyst rupture, and 46 % eventually underwent surgery, whereas the majority of patients (55 %) experienced symptomatic relief and did not undergo surgery. There was no significant association between a successful outcome and age, sex, level, or size of LFSC (p > 0.1). LFSCs with T2 hypointensity were more likely to require surgery (p = 0.02). There was one complication, a bacterial skin infection that completely resolved following antibiotic therapy. Percutaneous LFSC rupture is an effective and safe nonsurgical treatment option for LFSC. More than half of treated patients were able to avoid subsequent surgery. Therefore, percutaneous LFSC rupture should be considered before surgical intervention. (orig.)

  7. Predicting creep rupture from early strain data

    International Nuclear Information System (INIS)

    Holmstroem, Stefan; Auerkari, Pertti

    2009-01-01

    To extend creep life modelling from classical rupture modelling, a robust and effective parametric strain model has been developed. The model can reproduce with good accuracy all parts of the creep curve, economically utilising the available rupture models. The resulting combined model can also be used to predict rupture from the available strain data, and to further improve the rupture models. The methodology can utilise unfailed specimen data for life assessment at lower stress levels than what is possible from rupture data alone. Master curves for creep strain and rupture have been produced for oxygen-free phosphorus-doped (OFP) copper with a maximum testing time of 51,000 h. Values of time to specific strain at given stress (40-165 MPa) and temperature (125-350 deg. C) were fitted to the models in the strain range of 0.1-38%. With typical inhomogeneous multi-batch creep data, the combined strain and rupture modelling involves the steps of investigation of the data quality, extraction of elastic and creep strain response, rupture modelling, data set balancing and creep strain modelling. Finally, the master curves for strain and rupture are tested and validated for overall fitting efficiency. With the Wilshire equation as the basis for the rupture model, the strain model applies classical parametric principles with an Arrhenius type of thermal activation and a power law type of stress dependence for the strain rate. The strain model also assumes that the processes of primary and secondary creep can be reasonably correlated. The rupture model represents a clear improvement over previous models in the range of the test data. The creep strain information from interrupted and running tests were assessed together with the rupture data investigating the possibility of rupture model improvement towards lower stress levels by inverse utilisation of the combined rupture based strain model. The developed creep strain model together with the improved rupture model is

  8. Pengaruh Pemijatan Perineum pada Primigravida terhadap Kejadian Ruptur Perineum saat Persalinan di Bidan Praktek Mandiri di Kota Bengkulu Tahun 2014

    Directory of Open Access Journals (Sweden)

    Wewet Savitri

    2015-01-01

    Independent Practice of Midwifery in the city of Bengkulu year 2014. This study was a quasi-experimental study with the method of post test only control group design. The study was conducted in independent practice of midwifery in Bengkulu city including subject of 28 primigravida with 36 weeks of gestation consisting of 14 intervention group and 14 control group. The study was done from March 10th untill may 10th 2014, then the data were analyzed with chi- square test. Perineal rupture in the intervention group after perineal massage performed only 21.4% while in the control group was 71.4%. this study showed that there was effect of perineal massage on the incidence of perineal rupture of primigravida (p<0.05. This study concludes that perineal massage in primigravida can effected the incidence of perineal rupture at delivery.Keywords: perineal massage, primigravida, perineal

  9. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  10. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  11. Rupture of esophagus by compressed air.

    Science.gov (United States)

    Wu, Jie; Tan, Yuyong; Huo, Jirong

    2016-11-01

    Currently, beverages containing compressed air such as cola and champagne are widely used in our daily life. Improper ways to unscrew the bottle, usually by teeth, could lead to an injury, even a rupture of the esophagus. This letter to editor describes a case of esophageal rupture caused by compressed air.

  12. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  13. Treatment Alternative for Irreparable Rotator Cuff Ruptures ...

    African Journals Online (AJOL)

    2016-09-03

    Sep 3, 2016 ... and such ruptures also lead to a pseudo-paralysis.[1,2]. Pain during daily ... 2) repairable rotator cuff rupture, as determined on MRI and during arthroscopy ..... functioning and lead to cosmetic deformities.[4]. Arthroplasty is a ...

  14. Uterine rupture without previous caesarean delivery

    DEFF Research Database (Denmark)

    Thisted, Dorthe L. A.; H. Mortensen, Laust; Krebs, Lone

    2015-01-01

    to uterine rupture when adjusted for parity, epidural analgesia and augmentation by oxytocin. CONCLUSION: Although uterine rupture is rare, its association with epidural analgesia and augmentation of labour with oxytocin in multipara should be considered. Thus, vigilance should be exercised when labour...

  15. Spontaneous rupture of choledochal cyst: case report

    International Nuclear Information System (INIS)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young

    2002-01-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued

  16. Isolated gallbladder rupture following blunt abdominal injury

    African Journals Online (AJOL)

    2015-05-26

    May 26, 2015 ... Kaohsiung Medical University, Kaohsiung, Taiwan. Abstract. Isolated traumatic gallbladder rupture subsequent to blunt abdominal injury is rare. Most literatures on the subjects consist of case reports. We reported a rare case of isolated gallbladder rupture and discussed the possible predisposing factors to ...

  17. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  18. Spontaneous rupture of choledochal cyst: case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young [Dong-a University College of Medicine, Pusan (Korea, Republic of)

    2002-11-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued.

  19. Spontaneous rupture of adrenal metastasis from hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chae Hun; Kim, Hyun Jin; Park, Soo Youn; Hwang, Seong Su; Choi, Hyun Joo [St. Vincent Hospital, Suwon (Korea, Republic of)

    2007-03-15

    Rupture of adrenal tumor from various primary origins is a rather rare event. We report here on a ruptured adrenal metastasis from hepatocellular carcinoma, and this ruptured metastasis was observed at the time of the initial diagnosis.

  20. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  2. Earthquake lights and rupture processes

    Directory of Open Access Journals (Sweden)

    T. V. Losseva

    2005-01-01

    Full Text Available A physical model of earthquake lights is proposed. It is suggested that the magnetic diffusion from the electric and magnetic fields source region is a dominant process, explaining rather high localization of the light flashes. A 3D numerical code allowing to take into account the arbitrary distribution of currents caused by ground motion, conductivity in the ground and at its surface, including the existence of sea water above the epicenter or (and near the ruptured segments of the fault have been developed. Simulations for the 1995 Kobe earthquake were conducted taking into account the existence of sea water with realistic geometry of shores. The results do not contradict the eyewitness reports and scarce measurements of the electric and magnetic fields at large distances from the epicenter.

  3. Rupture of the meniscofibular ligament

    Directory of Open Access Journals (Sweden)

    Poyanli Oguz

    2010-05-01

    Full Text Available Abstract The meniscofibular ligament is an anatomically defined ligament of the knee in humans. However, there are no data regarding the prognosis following injury to this ligament. Our case was a 42-year-old man who presented at our clinic with pain of the lateral side of his left knee. MRI of his left knee revealed the rupture of the meniscofibular ligament. The mechanism of injury was consistent with anatomical and mechanical studies of the meniscofibular ligament. The patient was treated conservatively for 1 year, but his pain did not resolve completely. A case series of patients with the same injury is required to establish an effective treatment for this rare injury.

  4. Isolated posterior capsular rupture following blunt head trauma

    Directory of Open Access Journals (Sweden)

    Mansour AM

    2014-11-01

    Full Text Available Ahmad M Mansour, Mahmoud O Jaroudi, Rola N Hamam, Fadi C Maalouf Department of Ophthalmology, American University of Beirut, Beirut, Lebanon Abstract: Closed-globe traumatic cataract is not uncommon in males in the pediatric age group. However, there is a relative paucity of literature on isolated posterior lens capsule rupture associated with closed-globe traumatic cataract. We report a case of a 6-year-old boy who presented with white cataract 1 day after blunt trauma to the forehead associated with posterior capsular rupture that was detected by B-scan ultrasonography preoperatively. No stigmata of trauma outside the posterior capsule could be detected by slit-lamp exam, funduscopy, and optical coherence tomography. Phacoemulsification with posterior chamber intraocular lens implant was performed 24 hours after trauma, with the patient achieving 6/6 visual acuity 1 week and 6 months after surgery. Our case is unique, being the youngest (amblyogenic age to be reported, with prompt surgical intervention, and with no signs of trauma outside the posterior capsule. Keywords: posterior capsule rupture, forehead trauma, traumatic cataract, pediatric cataract

  5. CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

    International Nuclear Information System (INIS)

    Sommer, C. M.; Fritz, S.; Vollherbst, D.; Zelzer, S.; Wachter, M. F.; Bellemann, N.; Gockner, T.; Mokry, T.; Schmitz, A.; Aulmann, S.; Stampfl, U.; Pereira, P.; Kauczor, H. U.; Werner, J.; Radeleff, B. A.

    2015-01-01

    PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm 3 , and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm 3 , and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver

  6. CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Fritz, S., E-mail: stefan.fritz@med.uni-heidelberg.de [University Hospital Heidelberg, Department of General Visceral and Transplantation Surgery (Germany); Vollherbst, D., E-mail: dominikvollherbst@web.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Zelzer, S., E-mail: s.zelzer@dkfz-heidelberg.de [German Cancer Research Center (dkfz), Medical and Biological Informatics (Germany); Wachter, M. F., E-mail: fredericwachter@googlemail.com; Bellemann, N., E-mail: nadine.bellemann@med.uni-heidelberg.de; Gockner, T., E-mail: theresa.gockner@med.uni-heidelberg.de; Mokry, T., E-mail: theresa.mokry@med.uni-heidelberg.de; Schmitz, A., E-mail: anne.schmitz@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Aulmann, S., E-mail: sebastian.aulmann@mail.com [University Hospital Heidelberg, Department of General Pathology (Germany); Stampfl, U., E-mail: ulrike.stampfl@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Pereira, P., E-mail: philippe.pereira@slk-kliniken.de [SLK Kliniken Heilbronn GmbH, Clinic for Radiology, Minimally-invasive Therapies and Nuclear Medicine (Germany); Kauczor, H. U., E-mail: hu.kauczor@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Werner, J., E-mail: jens.werner@med.uni-heidelberg.de [University Hospital Heidelberg, Department of General Visceral and Transplantation Surgery (Germany); Radeleff, B. A., E-mail: boris.radeleff@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2015-02-15

    PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm{sup 3}, and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm{sup 3}, and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.

  7. Successful medical management of a neonate with spontaneous splenic rupture and severe hemophilia A.

    Science.gov (United States)

    Badawy, Sherif M; Rossoff, Jenna; Yallapragada, Sushmita; Liem, Robert I; Sharathkumar, Anjali A

    2017-03-01

    Splenic rupture in neonates is a rare event, usually occurring in the setting of underlying predisposing conditions. Here, we present the case of a term neonate who presented with worsening anemia in the setting of known hemolytic disease during the newborn period and was later found to have a spontaneous splenic rupture. He was subsequently diagnosed with severe hemophilia A, and was managed medically with recombinant factor VIII replacement therapy without any surgical intervention. This is the first reported case of a neonate who had spontaneous splenic rupture and severe hemophilia A, and underwent successful medical treatment without any surgical intervention. Copyright © 2016 King Faisal Specialist Hospital & Research Centre. Published by Elsevier Ltd. All rights reserved.

  8. A recent advance in the assessment of creep rupture data

    International Nuclear Information System (INIS)

    Holdsworth, S.R.

    1999-01-01

    A new procedure for the assessment of creep rupture data has been developed in the UK. The methodology features a state-of-the-art statistical treatment with independent checks on the physical realism, goodness of fit and extrapolation repeatability/stability of the model equation established to best characterise the behaviour of the material under investigation. Software provides semi-automation to allow full advantage to be taken of modern desk top computing power, but with ample provision for expert-user intervention. The paper reviews the background knowledge which underpins the new procedure and illustrates the method of implementation. (orig.)

  9. Metrics for comparing dynamic earthquake rupture simulations

    Science.gov (United States)

    Barall, Michael; Harris, Ruth A.

    2014-01-01

    Earthquakes are complex events that involve a myriad of interactions among multiple geologic features and processes. One of the tools that is available to assist with their study is computer simulation, particularly dynamic rupture simulation. A dynamic rupture simulation is a numerical model of the physical processes that occur during an earthquake. Starting with the fault geometry, friction constitutive law, initial stress conditions, and assumptions about the condition and response of the near‐fault rocks, a dynamic earthquake rupture simulation calculates the evolution of fault slip and stress over time as part of the elastodynamic numerical solution (Ⓔ see the simulation description in the electronic supplement to this article). The complexity of the computations in a dynamic rupture simulation make it challenging to verify that the computer code is operating as intended, because there are no exact analytic solutions against which these codes’ results can be directly compared. One approach for checking if dynamic rupture computer codes are working satisfactorily is to compare each code’s results with the results of other dynamic rupture codes running the same earthquake simulation benchmark. To perform such a comparison consistently, it is necessary to have quantitative metrics. In this paper, we present a new method for quantitatively comparing the results of dynamic earthquake rupture computer simulation codes.

  10. Hepatic Rupture Induced by Spontaneous Intrahepatic Hematoma

    Directory of Open Access Journals (Sweden)

    Jin-bao Zhou

    2018-01-01

    Full Text Available The etiology of hepatic rupture is usually secondary to trauma, and hepatic rupture induced by spontaneous intrahepatic hematoma is clinically rare. We describe here a 61-year-old female patient who was transferred to our hospital with hepatic rupture induced by spontaneous intrahepatic hematoma. The patient had no history of trauma and had a history of systemic lupus erythematosus for five years, taking a daily dose of 5 mg prednisone for treatment. The patients experienced durative blunt acute right upper abdominal pain one day after satiation, which aggravated in two hours, accompanied by dizziness and sweating. Preoperative diagnosis was rupture of the liver mass. Laparotomy revealed 2500 mL fluid consisting of a mixture of blood and clot in the peritoneal cavity. A 3.5 cm × 2.5 cm