WorldWideScience

Sample records for rule-based icd-9-cm coding

  1. Validation of ICD-9-CM coding algorithm for improved identification of hypoglycemia visits

    Directory of Open Access Journals (Sweden)

    Lieberman Rebecca M

    2008-04-01

    Full Text Available Abstract Background Accurate identification of hypoglycemia cases by International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM codes will help to describe epidemiology, monitor trends, and propose interventions for this important complication in patients with diabetes. Prior hypoglycemia studies utilized incomplete search strategies and may be methodologically flawed. We sought to validate a new ICD-9-CM coding algorithm for accurate identification of hypoglycemia visits. Methods This was a multicenter, retrospective cohort study using a structured medical record review at three academic emergency departments from July 1, 2005 to June 30, 2006. We prospectively derived a coding algorithm to identify hypoglycemia visits using ICD-9-CM codes (250.3, 250.8, 251.0, 251.1, 251.2, 270.3, 775.0, 775.6, and 962.3. We confirmed hypoglycemia cases by chart review identified by candidate ICD-9-CM codes during the study period. The case definition for hypoglycemia was documented blood glucose 3.9 mmol/l or emergency physician charted diagnosis of hypoglycemia. We evaluated individual components and calculated the positive predictive value. Results We reviewed 636 charts identified by the candidate ICD-9-CM codes and confirmed 436 (64% cases of hypoglycemia by chart review. Diabetes with other specified manifestations (250.8, often excluded in prior hypoglycemia analyses, identified 83% of hypoglycemia visits, and unspecified hypoglycemia (251.2 identified 13% of hypoglycemia visits. The absence of any predetermined co-diagnosis codes improved the positive predictive value of code 250.8 from 62% to 92%, while excluding only 10 (2% true hypoglycemia visits. Although prior analyses included only the first-listed ICD-9 code, more than one-quarter of identified hypoglycemia visits were outside this primary diagnosis field. Overall, the proposed algorithm had 89% positive predictive value (95% confidence interval, 86–92 for

  2. Leveraging the NLM map from SNOMED CT to ICD-10-CM to facilitate adoption of ICD-10-CM.

    Science.gov (United States)

    Cartagena, F Phil; Schaeffer, Molly; Rifai, Dorothy; Doroshenko, Victoria; Goldberg, Howard S

    2015-05-01

    Develop and test web services to retrieve and identify the most precise ICD-10-CM code(s) for a given clinical encounter. Facilitate creation of user interfaces that 1) provide an initial shortlist of candidate codes, ideally visible on a single screen; and 2) enable code refinement. To satisfy our high-level use cases, the analysis and design process involved reviewing available maps and crosswalks, designing the rule adjudication framework, determining necessary metadata, retrieving related codes, and iteratively improving the code refinement algorithm. The Partners ICD-10-CM Search and Mapping Services (PI-10 Services) are SOAP web services written using Microsoft's.NET 4.0 Framework, Windows Communications Framework, and SQL Server 2012. The services cover 96% of the Partners problem list subset of SNOMED CT codes that map to ICD-10-CM codes and can return up to 76% of the 69,823 billable ICD-10-CM codes prior to creation of custom mapping rules. We consider ways to increase 1) the coverage ratio of the Partners problem list subset of SNOMED CT codes and 2) the upper bound of returnable ICD-10-CM codes by creating custom mapping rules. Future work will investigate the utility of the transitive closure of SNOMED CT codes and other methods to assist in custom rule creation and, ultimately, to provide more complete coverage of ICD-10-CM codes. ICD-10-CM will be easier for clinicians to manage if applications display short lists of candidate codes from which clinicians can subsequently select a code for further refinement. The PI-10 Services support ICD-10 migration by implementing this paradigm and enabling users to consistently and accurately find the best ICD-10-CM code(s) without translation from ICD-9-CM. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Design, development and first validation of a transcoding system from ICD-9-CM to ICD-10 in the IT.DRG Italian project.

    Science.gov (United States)

    Della Mea, Vincenzo; Vuattolo, Omar; Frattura, Lucilla; Munari, Flavia; Verdini, Eleonora; Zanier, Loris; Arcangeli, Laura; Carle, Flavia

    2015-01-01

    In Italy, ICD-9-CM is currently used for coding health conditions at hospital discharge, but ICD-10 is being introduced thanks to the IT-DRG Project. In this project, one needed component is a set of transcoding rules and associated tools for easing coders work in the transition. The present paper illustrates design and development of those transcoding rules, and their preliminary testing on a subset of Italian hospital discharge data.

  4. Chiari malformation Type I surgery in pediatric patients. Part 1: validation of an ICD-9-CM code search algorithm.

    Science.gov (United States)

    Ladner, Travis R; Greenberg, Jacob K; Guerrero, Nicole; Olsen, Margaret A; Shannon, Chevis N; Yarbrough, Chester K; Piccirillo, Jay F; Anderson, Richard C E; Feldstein, Neil A; Wellons, John C; Smyth, Matthew D; Park, Tae Sung; Limbrick, David D

    2016-05-01

    OBJECTIVE Administrative billing data may facilitate large-scale assessments of treatment outcomes for pediatric Chiari malformation Type I (CM-I). Validated International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) code algorithms for identifying CM-I surgery are critical prerequisites for such studies but are currently only available for adults. The objective of this study was to validate two ICD-9-CM code algorithms using hospital billing data to identify pediatric patients undergoing CM-I decompression surgery. METHODS The authors retrospectively analyzed the validity of two ICD-9-CM code algorithms for identifying pediatric CM-I decompression surgery performed at 3 academic medical centers between 2001 and 2013. Algorithm 1 included any discharge diagnosis code of 348.4 (CM-I), as well as a procedure code of 01.24 (cranial decompression) or 03.09 (spinal decompression or laminectomy). Algorithm 2 restricted this group to the subset of patients with a primary discharge diagnosis of 348.4. The positive predictive value (PPV) and sensitivity of each algorithm were calculated. RESULTS Among 625 first-time admissions identified by Algorithm 1, the overall PPV for CM-I decompression was 92%. Among the 581 admissions identified by Algorithm 2, the PPV was 97%. The PPV for Algorithm 1 was lower in one center (84%) compared with the other centers (93%-94%), whereas the PPV of Algorithm 2 remained high (96%-98%) across all subgroups. The sensitivity of Algorithms 1 (91%) and 2 (89%) was very good and remained so across subgroups (82%-97%). CONCLUSIONS An ICD-9-CM algorithm requiring a primary diagnosis of CM-I has excellent PPV and very good sensitivity for identifying CM-I decompression surgery in pediatric patients. These results establish a basis for utilizing administrative billing data to assess pediatric CM-I treatment outcomes.

  5. Uncommon combinations of ICD10-PCS or ICD-9-CM operative procedure codes account for most inpatient surgery at half of Texas hospitals.

    Science.gov (United States)

    O'Neill, Liam; Dexter, Franklin; Park, Sae-Hwan; Epstein, Richard H

    2017-09-01

    Recently, there has been interest in activity-based cost accounting for inpatient surgical procedures to facilitate "value based" analyses. Research 10-20years ago, performed using data from 3 large teaching hospitals, found that activity-based cost accounting was practical and useful for modeling surgeons and subspecialties, but inaccurate for individual procedures. We hypothesized that these older results would apply to hundreds of hospitals, currently evaluable using administrative databases. Observational study. State of Texas hospital discharge abstract data for 1st quarter of 2016, 4th quarter of 2015, 1st quarter of 2015, and 4th quarter of 2014. Discharged from an acute care hospital in Texas with at least 1 major therapeutic ("operative") procedure. Counts of discharges for each procedure or combination of procedures, classified by ICD-10-PCS or ICD-9-CM. At the average hospital, most surgical discharges were for procedures performed at most once a month at the hospital (54%, 95% confidence interval [CI] 51% to 55%). At the average hospital, approximately 90% of procedures were performed at most once a month at the hospital (93%, CI 93% to 94%). The percentages were insensitive to the quarter of the year. The percentages were 3% to 6% greater with ICD-10-PCS than for the superseded ICD 9 CM. There are many different procedure codes, and many different combinations of codes, relative to the number of different hospital discharges. Since most procedures at most hospitals are performed no more than once a month, activity-based cost accounting with a sample size sufficient to be useful is impractical for the vast majority of procedures, in contrast to analysis by surgeon and/or subspecialty. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.

    Science.gov (United States)

    Weems, Shelley; Heller, Pamela; Fenton, Susan H

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.

  7. A Tale of Two Disability Coding Systems: The Veterans Administration Schedule for Rating Disabilities (VASRD) vs. Diagnostic Coding Using the International Classification of Diseases, 9th Edition, Clinical Modification (ICD-9-CM)

    Science.gov (United States)

    2008-01-01

    of ear and other sense organ disability cases with a disability-related CRO hospital record (N=234). Sickle - cell anemia was the most common...Hemic and Lymphatic Systems VASRD Group, 1984-1999. ICD-9-CM code (number and title) Frequency Percent of total* 282.6 Sickle - Cell Anemia 14...heterogeneous, and ICD-9-CM conditions linked to this VASRD include conditions that may be experienced by men and women. For example, 2 abdominal pain was

  8. 77 FR 8877 - ICD-9-CM Coordination and Maintenance (C&M) Committee Meeting

    Science.gov (United States)

    2012-02-15

    ...), Classifications and Public Health Data Standards Staff, announces the following meeting. Name: ICD-9-CM... proposed modifications to the International Classification of Diseases, Ninth-Revision, Clinical... Infusion of Glucarpidase ICD-10 Updates: ICD-10 MS-DRG Update ICD-10 HAC Translation List Impact of ICD-10...

  9. The Tragedy of the Implementation of ICD-10-CM as ICD-10: Is the Cart Before the Horse or Is There a Tragic Paradox of Misinformation and Ignorance?

    Science.gov (United States)

    Manchikanti, Laxmaiah; Kaye, Alan D; Singh, Vijay; Boswell, Mark V

    2015-01-01

    The forced implementation of ICD-10-CM (International Classification of Diseases, Tenth Revision, Clinical Modification) codes that are specific to the United States, scheduled for implementation October 1, 2015, which is vastly different from ICD-10 (International Classification of Diseases, Tenth Revision), implemented worldwide, which has 14,400 codes, compared to ICD-10-CM with 144,000 codes to be implemented in the United States is a major concern to practicing U.S. physicians and a bonanza for health IT and hospital industry. This implementation is based on a liberal interpretation of the Health Insurance Portability and Accountability Act (HIPAA), which requires an update to ICD-9-CM (International Classification of Diseases, Ninth Revision, Clinical Modification) and says nothing about ICD-10 or beyond. On June 29, 2015, the Supreme Court ruled that the Environmental Protection Agency unreasonably interpreted the Clean Air Act when it decided to set limits on the emissions of toxic pollutants from power plants, without first considering the costs on the industry. Thus, to do so is applicable to the medical industry with the Centers for Medicare and Medicaid Services (CMS) unreasonably interpreting HIPAA and imposing existent extensive regulations without considering the cost. In the United States, ICD-10-CM with a 10-fold increase in the number of codes has resulted in a system which has become so complicated that it no longer compares with any other country. Moreover, most WHO members use the ICD-10 system (not ICD-10-CM) only to record mortality in 138 countries or morbidity in 99 countries. Currently, only 10 countries employ ICD-10 (not ICD-10-CM) in the reimbursement process, 6 of which have a single payer health care system. Development of ICD-10-CM is managed by 4 non-physician groups, known as cooperating parties. They include the Centers for Disease Control and Prevention (CDC), CMS, the American Hospital Association (AHA), and the American Health

  10. Metrics and tools for consistent cohort discovery and financial analyses post-transition to ICD-10-CM.

    Science.gov (United States)

    Boyd, Andrew D; Li, Jianrong John; Kenost, Colleen; Joese, Binoy; Yang, Young Min; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A

    2015-05-01

    In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as "convoluted" by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: "identity" (reciprocal), "class-to-subclass," "subclass-to-class," "convoluted," or "no mapping." These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible.Web portal: http://www.lussierlab.org/transition-to-ICD9CM/Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  11. Validation of ICD-9 Codes for Stable Miscarriage in the Emergency Department.

    Science.gov (United States)

    Quinley, Kelly E; Falck, Ailsa; Kallan, Michael J; Datner, Elizabeth M; Carr, Brendan G; Schreiber, Courtney A

    2015-07-01

    International Classification of Disease, Ninth Revision (ICD-9) diagnosis codes have not been validated for identifying cases of missed abortion where a pregnancy is no longer viable but the cervical os remains closed. Our goal was to assess whether ICD-9 code "632" for missed abortion has high sensitivity and positive predictive value (PPV) in identifying patients in the emergency department (ED) with cases of stable early pregnancy failure (EPF). We studied females ages 13-50 years presenting to the ED of an urban academic medical center. We approached our analysis from two perspectives, evaluating both the sensitivity and PPV of ICD-9 code "632" in identifying patients with stable EPF. All patients with chief complaints "pregnant and bleeding" or "pregnant and cramping" over a 12-month period were identified. We randomly reviewed two months of patient visits and calculated the sensitivity of ICD-9 code "632" for true cases of stable miscarriage. To establish the PPV of ICD-9 code "632" for capturing missed abortions, we identified patients whose visits from the same time period were assigned ICD-9 code "632," and identified those with actual cases of stable EPF. We reviewed 310 patient records (17.6% of 1,762 sampled). Thirteen of 31 patient records assigned ICD-9 code for missed abortion correctly identified cases of stable EPF (sensitivity=41.9%), and 140 of the 142 patients without EPF were not assigned the ICD-9 code "632"(specificity=98.6%). Of the 52 eligible patients identified by ICD-9 code "632," 39 cases met the criteria for stable EPF (PPV=75.0%). ICD-9 code "632" has low sensitivity for identifying stable EPF, but its high specificity and moderately high PPV are valuable for studying cases of stable EPF in epidemiologic studies using administrative data.

  12. A comparison of two methods for retrieving ICD-9-CM data: the effect of using an ontology-based method for handling terminology changes.

    Science.gov (United States)

    Yu, Alexander C; Cimino, James J

    2011-04-01

    Most existing controlled terminologies can be characterized as collections of terms, wherein the terms are arranged in a simple list or organized in a hierarchy. These kinds of terminologies are considered useful for standardizing terms and encoding data and are currently used in many existing information systems. However, they suffer from a number of limitations that make data reuse difficult. Relatively recently, it has been proposed that formal ontological methods can be applied to some of the problems of terminological design. Biomedical ontologies organize concepts (embodiments of knowledge about biomedical reality) whereas terminologies organize terms (what is used to code patient data at a certain point in time, based on the particular terminology version). However, the application of these methods to existing terminologies is not straightforward. The use of these terminologies is firmly entrenched in many systems, and what might seem to be a simple option of replacing these terminologies is not possible. Moreover, these terminologies evolve over time in order to suit the needs of users. Any methodology must therefore take these constraints into consideration, hence the need for formal methods of managing changes. Along these lines, we have developed a formal representation of the concept-term relation, around which we have also developed a methodology for management of terminology changes. The objective of this study was to determine whether our methodology would result in improved retrieval of data. Comparison of two methods for retrieving data encoded with terms from the International Classification of Diseases (ICD-9-CM), based on their recall when retrieving data for ICD-9-CM terms whose codes had changed but which had retained their original meaning (code change). Recall and interclass correlation coefficient. Statistically significant differences were detected (pontology-based ICD-9-CM data retrieval method that takes into account the effects of

  13. Issues in Developing a Surveillance Case Definition for Nonfatal Suicide Attempt and Intentional Self-harm Using International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM) Coded Data.

    Science.gov (United States)

    Hedegaard, Holly; Schoenbaum, Michael; Claassen, Cynthia; Crosby, Alex; Holland, Kristin; Proescholdbell, Scott

    2018-02-01

    Suicide and intentional self-harm are among the leading causes of death in the United States. To study this public health issue, epidemiologists and researchers often analyze data coded using the International Classification of Diseases (ICD). Prior to October 1, 2015, health care organizations and providers used the clinical modification of the Ninth Revision of ICD (ICD-9-CM) to report medical information in electronic claims data. The transition in October 2015 to use of the clinical modification of the Tenth Revision of ICD (ICD-10-CM) resulted in the need to update methods and selection criteria previously developed for ICD-9-CM coded data. This report provides guidance on the use of ICD-10-CM codes to identify cases of nonfatal suicide attempts and intentional self-harm in ICD-10-CM coded data sets. ICD-10-CM codes for nonfatal suicide attempts and intentional self-harm include: X71-X83, intentional self-harm due to drowning and submersion, firearms, explosive or thermal material, sharp or blunt objects, jumping from a high place, jumping or lying in front of a moving object, crashing of motor vehicle, and other specified means; T36-T50 with a 6th character of 2 (except for T36.9, T37.9, T39.9, T41.4, T42.7, T43.9, T45.9, T47.9, and T49.9, which are included if the 5th character is 2), intentional self-harm due to drug poisoning (overdose); T51-T65 with a 6th character of 2 (except for T51.9, T52.9, T53.9, T54.9, T56.9, T57.9, T58.0, T58.1, T58.9, T59.9, T60.9, T61.0, T61.1, T61.9, T62.9, T63.9, T64.0, T64.8, and T65.9, which are included if the 5th character is 2), intentional self-harm due to toxic effects of nonmedicinal substances; T71 with a 6th character of 2, intentional self-harm due to asphyxiation, suffocation, strangulation; and T14.91, Suicide attempt. Issues to consider when selecting records for nonfatal suicide attempts and intentional self-harm from ICD-10-CM coded administrative data sets are also discussed. All material appearing in this

  14. An administrative data merging solution for dealing with missing data in a clinical registry: adaptation from ICD-9 to ICD-10

    Directory of Open Access Journals (Sweden)

    Galbraith P Diane

    2008-01-01

    Full Text Available Abstract Background We have previously described a method for dealing with missing data in a prospective cardiac registry initiative. The method involves merging registry data to corresponding ICD-9-CM administrative data to fill in missing data 'holes'. Here, we describe the process of translating our data merging solution to ICD-10, and then validating its performance. Methods A multi-step translation process was undertaken to produce an ICD-10 algorithm, and merging was then implemented to produce complete datasets for 1995–2001 based on the ICD-9-CM coding algorithm, and for 2002–2005 based on the ICD-10 algorithm. We used cardiac registry data for patients undergoing cardiac catheterization in fiscal years 1995–2005. The corresponding administrative data records were coded in ICD-9-CM for 1995–2001 and in ICD-10 for 2002–2005. The resulting datasets were then evaluated for their ability to predict death at one year. Results The prevalence of the individual clinical risk factors increased gradually across years. There was, however, no evidence of either an abrupt drop or rise in prevalence of any of the risk factors. The performance of the new data merging model was comparable to that of our previously reported methodology: c-statistic = 0.788 (95% CI 0.775, 0.802 for the ICD-10 model versus c-statistic = 0.784 (95% CI 0.780, 0.790 for the ICD-9-CM model. The two models also exhibited similar goodness-of-fit. Conclusion The ICD-10 implementation of our data merging method performs as well as the previously-validated ICD-9-CM method. Such methodological research is an essential prerequisite for research with administrative data now that most health systems are transitioning to ICD-10.

  15. Exploration of ICD-9-CM Coding of Chronic Disease within the Elixhauser Comorbidity Measure in Patients with Chronic Heart Failure

    Science.gov (United States)

    Garvin, Jennifer Hornung; Redd, Andrew; Bolton, Dan; Graham, Pauline; Roche, Dominic; Groeneveld, Peter; Leecaster, Molly; Shen, Shuying; Weiner, Mark G.

    2013-01-01

    Introduction International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes capture comorbidities that can be used to risk adjust nonrandom patient groups. We explored the accuracy of capturing comorbidities associated with one risk adjustment method, the Elixhauser Comorbidity Measure (ECM), in patients with chronic heart failure (CHF) at one Veterans Affairs (VA) medical center. We explored potential reasons for the differences found between the original codes assigned and conditions found through retrospective review. Methods This descriptive, retrospective study used a cohort of patients discharged with a principal diagnosis coded as CHF from one VA medical center in 2003. One admission per patient was used in the study; with multiple admissions, only the first admission was analyzed. We compared the assignment of original codes assigned to conditions found in a retrospective, manual review of the medical record conducted by an investigator with coding expertise as well as by physicians. Members of the team experienced with assigning ICD-9-CM codes and VA coding processes developed themes related to systemic reasons why chronic conditions were not coded in VA records using applied thematic techniques. Results In the 181-patient cohort, 388 comorbid conditions were identified; 305 of these were chronic conditions, originally coded at the time of discharge with an average of 1.7 comorbidities related to the ECM per patient. The review by an investigator with coding expertise revealed a total of 937 comorbidities resulting in 618 chronic comorbid conditions with an average of 3.4 per patient; physician review found 872 total comorbidities with 562 chronic conditions (average 3.1 per patient). The agreement between the original and the retrospective coding review was 88 percent. The kappa statistic for the original and the retrospective coding review was 0.375 with a 95 percent confidence interval (CI) of 0.352 to 0.398. The kappa

  16. From Novice to Expert: Problem Solving in ICD-10-PCS Procedural Coding

    Science.gov (United States)

    Rousse, Justin Thomas

    2013-01-01

    The benefits of converting to ICD-10-CM/PCS have been well documented in recent years. One of the greatest challenges in the conversion, however, is how to train the workforce in the code sets. The International Classification of Diseases, Tenth Revision, Procedure Coding System (ICD-10-PCS) has been described as a language requiring higher-level reasoning skills because of the system's increased granularity. Training and problem-solving strategies required for correct procedural coding are unclear. The objective of this article is to propose that the acquisition of rule-based logic will need to be augmented with self-evaluative and critical thinking. Awareness of how this process works is helpful for established coders as well as for a new generation of coders who will master the complexities of the system. PMID:23861674

  17. Migration to the ICD-10 coding system: A primer for spine surgeons (Part 1).

    Science.gov (United States)

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    On 1 October 2015, a new federally mandated system goes into effect requiring the replacement of the International Classification of Disease-version 9-Clinical Modification (ICD-9-CM) with ICD-10-CM. These codes are required to be used for reimbursement and to substantiate medical necessity. ICD-10 is composite with as many as 141,000 codes, an increase of 712% when compared to ICD-9. Execution of the ICD-10 system will require significant changes in the clinical administrative and hospital-based practices. Through the transition, diminished productivity and practice revenue can be anticipated, the impacts of which the spine surgeon can minimizeby appropriate education and planning. The advantages of the new system include increased clarity and more accurate definitions reflecting patient condition, information relevant to ambulatory and managed care encounters, expanded injury codes, laterality, specificity, precise data for safety and compliance reporting, data mining for research, and finally, enabling pay-for-performance programs. The disadvantages include the cost per physician, training administrative staff, revenue loss during the learning curve, confusion, the need to upgrade hardware along with software, and overall expense to the healthcare system. With the deadline rapidly approaching, gaps in implementation result in delayed billing, delayed or diminished reimbursements, and absence of quality and outcomes data. It is thereby essential for spine surgeons to understand their role in transitioning to this new environment. Part I of this article discusses the background, coding changes, and costs as well as reviews the salient features of ICD-10 in spine surgery.

  18. Identifying priorities in methodological research using ICD-9-CM and ICD-10 administrative data: report from an international consortium

    Directory of Open Access Journals (Sweden)

    Ma Jin

    2006-06-01

    Full Text Available Abstract Background Health administrative data are frequently used for health services and population health research. Comparative research using these data has been facilitated by the use of a standard system for coding diagnoses, the International Classification of Diseases (ICD. Research using the data must deal with data quality and validity limitations which arise because the data are not created for research purposes. This paper presents a list of high-priority methodological areas for researchers using health administrative data. Methods A group of researchers and users of health administrative data from Canada, the United States, Switzerland, Australia, China and the United Kingdom came together in June 2005 in Banff, Canada to discuss and identify high-priority methodological research areas. The generation of ideas for research focussed not only on matters relating to the use of administrative data in health services and population health research, but also on the challenges created in transitioning from ICD-9 to ICD-10. After the brain-storming session, voting took place to rank-order the suggested projects. Participants were asked to rate the importance of each project from 1 (low priority to 10 (high priority. Average ranks were computed to prioritise the projects. Results Thirteen potential areas of research were identified, some of which represented preparatory work rather than research per se. The three most highly ranked priorities were the documentation of data fields in each country's hospital administrative data (average score 8.4, the translation of patient safety indicators from ICD-9 to ICD-10 (average score 8.0, and the development and validation of algorithms to verify the logic and internal consistency of coding in hospital abstract data (average score 7.0. Conclusion The group discussions resulted in a list of expert views on critical international priorities for future methodological research relating to health

  19. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations.

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-08-05

    With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Identification of ICD Codes Suggestive of Child Maltreatment

    Science.gov (United States)

    Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.

    2011-01-01

    Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…

  1. Use of ontology structure and Bayesian models to aid the crowdsourcing of ICD-11 sanctioning rules.

    Science.gov (United States)

    Lou, Yun; Tu, Samson W; Nyulas, Csongor; Tudorache, Tania; Chalmers, Robert J G; Musen, Mark A

    2017-04-01

    The International Classification of Diseases (ICD) is the de facto standard international classification for mortality reporting and for many epidemiological, clinical, and financial use cases. The next version of ICD, ICD-11, will be submitted for approval by the World Health Assembly in 2018. Unlike previous versions of ICD, where coders mostly select single codes from pre-enumerated disease and disorder codes, ICD-11 coding will allow extensive use of multiple codes to give more detailed disease descriptions. For example, "severe malignant neoplasms of left breast" may be coded using the combination of a "stem code" (e.g., code for malignant neoplasms of breast) with a variety of "extension codes" (e.g., codes for laterality and severity). The use of multiple codes (a process called post-coordination), while avoiding the pitfall of having to pre-enumerate vast number of possible disease and qualifier combinations, risks the creation of meaningless expressions that combine stem codes with inappropriate qualifiers. To prevent that from happening, "sanctioning rules" that define legal combinations are necessary. In this work, we developed a crowdsourcing method for obtaining sanctioning rules for the post-coordination of concepts in ICD-11. Our method utilized the hierarchical structures in the domain to improve the accuracy of the sanctioning rules and to lower the crowdsourcing cost. We used Bayesian networks to model crowd workers' skills, the accuracy of their responses, and our confidence in the acquired sanctioning rules. We applied reinforcement learning to develop an agent that constantly adjusted the confidence cutoffs during the crowdsourcing process to maximize the overall quality of sanctioning rules under a fixed budget. Finally, we performed formative evaluations using a skin-disease branch of the draft ICD-11 and demonstrated that the crowd-sourced sanctioning rules replicated those defined by an expert dermatologist with high precision and recall

  2. Comparison of ICD code-based diagnosis of obesity with measured obesity in children and the implications for health care cost estimates.

    Science.gov (United States)

    Kuhle, Stefan; Kirk, Sara F L; Ohinmaa, Arto; Veugelers, Paul J

    2011-12-21

    Administrative health databases are a valuable research tool to assess health care utilization at the population level. However, their use in obesity research limited due to the lack of data on body weight. A potential workaround is to use the ICD code of obesity to identify obese individuals. The objective of the current study was to investigate the sensitivity and specificity of an ICD code-based diagnosis of obesity from administrative health data relative to the gold standard measured BMI. Linkage of a population-based survey with anthropometric measures in elementary school children in 2003 with longitudinal administrative health data (physician visits and hospital discharges 1992-2006) from the Canadian province of Nova Scotia. Measured obesity was defined based on the CDC cut-offs applied to the measured BMI. An ICD code-based diagnosis obesity was defined as one or more ICD-9 (278) or ICD-10 code (E66-E68) of obesity from a physician visit or a hospital stay. Sensitivity and specificity were calculated and health care cost estimates based on measured obesity and ICD-based obesity were compared. The sensitivity of an ICD code-based obesity diagnosis was 7.4% using ICD codes between 2002 and 2004. Those correctly identified had a higher BMI and had higher health care utilization and costs. An ICD diagnosis of obesity in Canadian administrative health data grossly underestimates the true prevalence of childhood obesity and overestimates the health care cost differential between obese and non-obese children.

  3. Coding update of the SMFM definition of low risk for cesarean delivery from ICD-9-CM to ICD-10-CM.

    Science.gov (United States)

    Armstrong, Joanne; McDermott, Patricia; Saade, George R; Srinivas, Sindhu K

    2017-07-01

    In 2015, the Society for Maternal-Fetal Medicine developed a low risk for cesarean delivery definition based on administrative claims-based diagnosis codes described by the International Classification of Diseases, Ninth Revision, Clinical Modification. The Society for Maternal-Fetal Medicine definition is a clinical enrichment of 2 available measures from the Joint Commission and the Agency for Healthcare Research and Quality measures. The Society for Maternal-Fetal Medicine measure excludes diagnosis codes that represent clinically relevant risk factors that are absolute or relative contraindications to vaginal birth while retaining diagnosis codes such as labor disorders that are discretionary risk factors for cesarean delivery. The introduction of the International Statistical Classification of Diseases, 10th Revision, Clinical Modification in October 2015 expanded the number of available diagnosis codes and enabled a greater depth and breadth of clinical description. These coding improvements further enhance the clinical validity of the Society for Maternal-Fetal Medicine definition and its potential utility in tracking progress toward the goal of safely lowering the US cesarean delivery rate. This report updates the Society for Maternal-Fetal Medicine definition of low risk for cesarean delivery using International Statistical Classification of Diseases, 10th Revision, Clinical Modification coding. Copyright © 2017. Published by Elsevier Inc.

  4. Validity of International Classification of Diseases (ICD) coding for dengue infections in hospital discharge records in Malaysia.

    Science.gov (United States)

    Woon, Yuan-Liang; Lee, Keng-Yee; Mohd Anuar, Siti Fatimah Zahra; Goh, Pik-Pin; Lim, Teck-Onn

    2018-04-20

    Hospitalization due to dengue illness is an important measure of dengue morbidity. However, limited studies are based on administrative database because the validity of the diagnosis codes is unknown. We validated the International Classification of Diseases, 10th revision (ICD) diagnosis coding for dengue infections in the Malaysian Ministry of Health's (MOH) hospital discharge database. This validation study involves retrospective review of available hospital discharge records and hand-search medical records for years 2010 and 2013. We randomly selected 3219 hospital discharge records coded with dengue and non-dengue infections as their discharge diagnoses from the national hospital discharge database. We then randomly sampled 216 and 144 records for patients with and without codes for dengue respectively, in keeping with their relative frequency in the MOH database, for chart review. The ICD codes for dengue were validated against lab-based diagnostic standard (NS1 or IgM). The ICD-10-CM codes for dengue had a sensitivity of 94%, modest specificity of 83%, positive predictive value of 87% and negative predictive value 92%. These results were stable between 2010 and 2013. However, its specificity decreased substantially when patients manifested with bleeding or low platelet count. The diagnostic performance of the ICD codes for dengue in the MOH's hospital discharge database is adequate for use in health services research on dengue.

  5. Coding algorithms for identifying patients with cirrhosis and hepatitis B or C virus using administrative data.

    Science.gov (United States)

    Niu, Bolin; Forde, Kimberly A; Goldberg, David S

    2015-01-01

    Despite the use of administrative data to perform epidemiological and cost-effectiveness research on patients with hepatitis B or C virus (HBV, HCV), there are no data outside of the Veterans Health Administration validating whether International Classification of Disease, Ninth Revision, Clinical Modification (ICD-9-CM) codes can accurately identify cirrhotic patients with HBV or HCV. The validation of such algorithms is necessary for future epidemiological studies. We evaluated the positive predictive value (PPV) of ICD-9-CM codes for identifying chronic HBV or HCV among cirrhotic patients within the University of Pennsylvania Health System, a large network that includes a tertiary care referral center, a community-based hospital, and multiple outpatient practices across southeastern Pennsylvania and southern New Jersey. We reviewed a random sample of 200 cirrhotic patients with ICD-9-CM codes for HCV and 150 cirrhotic patients with ICD-9-CM codes for HBV. The PPV of 1 inpatient or 2 outpatient HCV codes was 88.0% (168/191, 95% CI: 82.5-92.2%), while the PPV of 1 inpatient or 2 outpatient HBV codes was 81.3% (113/139, 95% CI: 73.8-87.4%). Several variations of the primary coding algorithm were evaluated to determine if different combinations of inpatient and/or outpatient ICD-9-CM codes could increase the PPV of the coding algorithm. ICD-9-CM codes can identify chronic HBV or HCV in cirrhotic patients with a high PPV and can be used in future epidemiologic studies to examine disease burden and the proper allocation of resources. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Diagnosis-based and external cause-based criteria to identify adverse drug reactions in hospital ICD-coded data: application to an Australia population-based study

    Directory of Open Access Journals (Sweden)

    Wei Du

    2017-04-01

    Full Text Available Objectives: External cause International Classification of Diseases (ICD codes are commonly used to ascertain adverse drug reactions (ADRs related to hospitalisation. We quantified ascertainment of ADR-related hospitalisation using external cause codes and additional ICD-based hospital diagnosis codes. Methods: We reviewed the scientific literature to identify different ICD-based criteria for ADR-related hospitalisations, developed algorithms to capture ADRs based on candidate hospital ICD-10 diagnoses and external cause codes (Y40–Y59, and incorporated previously published causality ratings estimating the probability that a specific diagnosis was ADR related. We applied the algorithms to the NSW Admitted Patient Data Collection records of 45 and Up Study participants (2011–2013. Results: Of 493 442 hospitalisations among 267 153 study participants during 2011–2013, 18.8% (n = 92 953 had hospital diagnosis codes that were potentially ADR related; 1.1% (n = 5305 had high/very high–probability ADR-related diagnosis codes (causality ratings: A1 and A2; and 2.0% (n = 10 039 had ADR-related external cause codes. Overall, 2.2% (n = 11 082 of cases were classified as including an ADR-based hospitalisation on either external cause codes or high/very high–probability ADR-related diagnosis codes. Hence, adding high/very high–probability ADR-related hospitalisation codes to standard external cause codes alone (Y40–Y59 increased the number of hospitalisations classified as having an ADR-related diagnosis by 10.4%. Only 6.7% of cases with high-probability ADR-related mental symptoms were captured by external cause codes. Conclusion: Selective use of high-probability ADR-related hospital diagnosis codes in addition to external cause codes yielded a modest increase in hospitalised ADR incidence, which is of potential clinical significance. Clinically validated combinations of diagnosis codes could potentially further enhance capture.

  7. Insurance billing and coding.

    Science.gov (United States)

    Napier, Rebecca H; Bruelheide, Lori S; Demann, Eric T K; Haug, Richard H

    2008-07-01

    The purpose of this article is to highlight the importance of understanding various numeric and alpha-numeric codes for accurately billing dental and medically related services to private pay or third-party insurance carriers. In the United States, common dental terminology (CDT) codes are most commonly used by dentists to submit claims, whereas current procedural terminology (CPT) and International Classification of Diseases, Ninth Revision, Clinical Modification (ICD.9.CM) codes are more commonly used by physicians to bill for their services. The CPT and ICD.9.CM coding systems complement each other in that CPT codes provide the procedure and service information and ICD.9.CM codes provide the reason or rationale for a particular procedure or service. These codes are more commonly used for "medical necessity" determinations, and general dentists and specialists who routinely perform care, including trauma-related care, biopsies, and dental treatment as a result of or in anticipation of a cancer-related treatment, are likely to use these codes. Claim submissions for care provided can be completed electronically or by means of paper forms.

  8. Diabetes Mellitus Coding Training for Family Practice Residents.

    Science.gov (United States)

    Urse, Geraldine N

    2015-07-01

    Although physicians regularly use numeric coding systems such as the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) to describe patient encounters, coding errors are common. One of the most complicated diagnoses to code is diabetes mellitus. The ICD-9-CM currently has 39 separate codes for diabetes mellitus; this number will be expanded to more than 50 with the introduction of ICD-10-CM in October 2015. To assess the effect of a 1-hour focused presentation on ICD-9-CM codes on diabetes mellitus coding. A 1-hour focused lecture on the correct use of diabetes mellitus codes for patient visits was presented to family practice residents at Doctors Hospital Family Practice in Columbus, Ohio. To assess resident knowledge of the topic, a pretest and posttest were given to residents before and after the lecture, respectively. Medical records of all patients with diabetes mellitus who were cared for at the hospital 6 weeks before and 6 weeks after the lecture were reviewed and compared for the use of diabetes mellitus ICD-9 codes. Eighteen residents attended the lecture and completed the pretest and posttest. The mean (SD) percentage of correct answers was 72.8% (17.1%) for the pretest and 84.4% (14.6%) for the posttest, for an improvement of 11.6 percentage points (P≤.035). The percentage of total available codes used did not substantially change from before to after the lecture, but the use of the generic ICD-9-CM code for diabetes mellitus type II controlled (250.00) declined (58 of 176 [33%] to 102 of 393 [26%]) and the use of other codes increased, indicating a greater variety in codes used after the focused lecture. After a focused lecture on diabetes mellitus coding, resident coding knowledge improved. Review of medical record data did not reveal an overall change in the number of diabetic codes used after the lecture but did reveal a greater variety in the codes used.

  9. Case-Mix for Performance Management: A Risk Algorithm Based on ICD-10-CM.

    Science.gov (United States)

    Gao, Jian; Moran, Eileen; Almenoff, Peter L

    2018-06-01

    Accurate risk adjustment is the key to a reliable comparison of cost and quality performance among providers and hospitals. However, the existing case-mix algorithms based on age, sex, and diagnoses can only explain up to 50% of the cost variation. More accurate risk adjustment is desired for provider performance assessment and improvement. To develop a case-mix algorithm that hospitals and payers can use to measure and compare cost and quality performance of their providers. All 6,048,895 patients with valid diagnoses and cost recorded in the US Veterans health care system in fiscal year 2016 were included in this study. The dependent variable was total cost at the patient level, and the explanatory variables were age, sex, and comorbidities represented by 762 clinically homogeneous groups, which were created by expanding the 283 categories from Clinical Classifications Software based on ICD-10-CM codes. The split-sample method was used to assess model overfitting and coefficient stability. The predictive power of the algorithms was ascertained by comparing the R, mean absolute percentage error, root mean square error, predictive ratios, and c-statistics. The expansion of the Clinical Classifications Software categories resulted in higher predictive power. The R reached 0.72 and 0.52 for the transformed and raw scale cost, respectively. The case-mix algorithm we developed based on age, sex, and diagnoses outperformed the existing case-mix models reported in the literature. The method developed in this study can be used by other health systems to produce tailored risk models for their specific purpose.

  10. Piloting a Collaborative Web-Based System for Testing ICD-11.

    Science.gov (United States)

    Donada, Marc; Kostanjsek, Nenad; Della Mea, Vincenzo; Celik, Can; Jakob, Robert

    2017-01-01

    The 11th revision of the International Classification of Diseases (ICD-11), for the first time in ICD history, deployed web-based collaboration of experts and ICT tools. To ensure that ICD-11 is working well, it needs to be systematically field tested in different settings, across the world. This will be done by means of a number of experiments. In order to support its implementation, a web-based system (ICDfit) has been designed and developed. The present paper illustrates the current prototype of the system and its technical testing. the system has been designed according to WHO requirements, and implemented using PHP and MySQL. Then, a preliminary technical test has been designed and run in January 2016, involving 8 users. They had to carry out double coding, that is, coding case summaries with both ICD-10 and ICD-11, and answering quick questions on the coding difficulty. the 8 users coded 632 cases each, spending an average of 163 seconds per case. While we found an issue in the mechanism used to record coding times, no further issues were found. the proposed system seems to be technically adequate for supporting future ICD-11 testing.

  11. Performance Measures of Diagnostic Codes for Detecting Opioid Overdose in the Emergency Department.

    Science.gov (United States)

    Rowe, Christopher; Vittinghoff, Eric; Santos, Glenn-Milo; Behar, Emily; Turner, Caitlin; Coffin, Phillip O

    2017-04-01

    Opioid overdose mortality has tripled in the United States since 2000 and opioids are responsible for more than half of all drug overdose deaths, which reached an all-time high in 2014. Opioid overdoses resulting in death, however, represent only a small fraction of all opioid overdose events and efforts to improve surveillance of this public health problem should include tracking nonfatal overdose events. International Classification of Disease (ICD) diagnosis codes, increasingly used for the surveillance of nonfatal drug overdose events, have not been rigorously assessed for validity in capturing overdose events. The present study aimed to validate the use of ICD, 9th revision, Clinical Modification (ICD-9-CM) codes in identifying opioid overdose events in the emergency department (ED) by examining multiple performance measures, including sensitivity and specificity. Data on ED visits from January 1, 2012, to December 31, 2014, including clinical determination of whether the visit constituted an opioid overdose event, were abstracted from electronic medical records for patients prescribed long-term opioids for pain from any of six safety net primary care clinics in San Francisco, California. Combinations of ICD-9-CM codes were validated in the detection of overdose events as determined by medical chart review. Both sensitivity and specificity of different combinations of ICD-9-CM codes were calculated. Unadjusted logistic regression models with robust standard errors and accounting for clustering by patient were used to explore whether overdose ED visits with certain characteristics were more or less likely to be assigned an opioid poisoning ICD-9-CM code by the documenting physician. Forty-four (1.4%) of 3,203 ED visits among 804 patients were determined to be opioid overdose events. Opioid-poisoning ICD-9-CM codes (E850.2-E850.2, 965.00-965.09) identified overdose ED visits with a sensitivity of 25.0% (95% confidence interval [CI] = 13.6% to 37.8%) and

  12. 77 FR 32975 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs)

    Science.gov (United States)

    2012-06-04

    ... on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) AGENCY: Agency for Healthcare Research and... workgroups, to be convened by AHRQ's contractor, on ICD-10-CM/PCS conversion of the AHRQ Quality Indicators..., please visit the AHRQ Web site at http://www.QUALITYindicators.AHRQ.gov . Specifically, each Workgroup on...

  13. Implementation and impact of ICD-10 (Part II).

    Science.gov (United States)

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    The transition from the International Classification of Disease-9(th) clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices.

  14. What diagnoses may make patients more seriously ill than they first appear? Mortality according to the Simple Clinical Score Risk Class at the time of admission compared to the observed mortality of different ICD9 codes identified on death or discharge.

    LENUS (Irish Health Repository)

    Kellett, John

    2009-01-01

    The Simple Clinical Score (SCS) determined at the time of admission places acutely ill general medical patients into one of five risk classes associated with an increasing risk of death within 30 days. The cohort of acute medical patient that the SCS was derived from had, on average, four combinations of 74 groupings of ICD9 codes. This paper reports the ICD9 codes associated with the different SCS risk classes and identifies those ICD9 codes with a greater observed mortality than that of other patients in the same SCS risk class.

  15. Fatal anaphylaxis registries data support changes in the who anaphylaxis mortality coding rules.

    Science.gov (United States)

    Tanno, Luciana Kase; Simons, F Estelle R; Annesi-Maesano, Isabella; Calderon, Moises A; Aymé, Ségolène; Demoly, Pascal

    2017-01-13

    Anaphylaxis is defined as a severe life-threatening generalized or systemic hypersensitivity reaction. The difficulty of coding anaphylaxis fatalities under the World Health Organization (WHO) International Classification of Diseases (ICD) system is recognized as an important reason for under-notification of anaphylaxis deaths. On current death certificates, a limited number of ICD codes are valid as underlying causes of death, and death certificates do not include the word anaphylaxis per se. In this review, we provide evidences supporting the need for changes in WHO mortality coding rules and call for addition of anaphylaxis as an underlying cause of death on international death certificates. This publication will be included in support of a formal request to the WHO as a formal request for this move taking the 11 th ICD revision.

  16. Accuracy of ICD-10 Coding System for Identifying Comorbidities and Infectious Conditions Using Data from a Thai University Hospital Administrative Database.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Wongkamhla, Thanyarak; Thamlikitkul, Visanu

    2016-04-01

    To determine the accuracy of International Statistical Classification of Disease and Related Health Problems, 10th Revision (ICD-10) coding system in identifying comorbidities and infectious conditions using data from a Thai university hospital administrative database. A retrospective cross-sectional study was conducted among patients hospitalized in six general medicine wards at Siriraj Hospital. ICD-10 code data was identified and retrieved directly from the hospital administrative database. Patient comorbidities were captured using the ICD-10 coding algorithm for the Charlson comorbidity index. Infectious conditions were captured using the groups of ICD-10 diagnostic codes that were carefully prepared by two independent infectious disease specialists. Accuracy of ICD-10 codes combined with microbiological dataf or diagnosis of urinary tract infection (UTI) and bloodstream infection (BSI) was evaluated. Clinical data gathered from chart review was considered the gold standard in this study. Between February 1 and May 31, 2013, a chart review of 546 hospitalization records was conducted. The mean age of hospitalized patients was 62.8 ± 17.8 years and 65.9% of patients were female. Median length of stay [range] was 10.0 [1.0-353.0] days and hospital mortality was 21.8%. Conditions with ICD-10 codes that had good sensitivity (90% or higher) were diabetes mellitus and HIV infection. Conditions with ICD-10 codes that had good specificity (90% or higher) were cerebrovascular disease, chronic lung disease, diabetes mellitus, cancer HIV infection, and all infectious conditions. By combining ICD-10 codes with microbiological results, sensitivity increased from 49.5 to 66%for UTI and from 78.3 to 92.8%for BS. The ICD-10 coding algorithm is reliable only in some selected conditions, including underlying diabetes mellitus and HIV infection. Combining microbiological results with ICD-10 codes increased sensitivity of ICD-10 codes for identifying BSI. Future research is

  17. International common-cause failure data exchange. ICDE general coding guidelines - Technical note

    International Nuclear Information System (INIS)

    Johanson, Gunnar; Werner, Wolfgang; Concepcion Capote, Marina; Kreuser, Albert; Rasmuson, Dale; Jonsson, Esther; Pereira Pagan, Begona; Tirira, Jorge; Morris, Ian; Morales, Rosa; Oxberry, Anna; Kreuser, Albert

    2004-01-01

    Several Member countries of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA) have established the International Common-Cause Failure Data Exchange Project (ICDE Project) to encourage multilateral co-operation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The objectives of the ICDE Project are to: a) Collect and analyse CCF events over the long term so as to better understand such events, their causes, and their prevention; b) Generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences; c) Establish a mechanism for the efficient feedback of experience gained in connection with CCF phenomena, including the development of defences against their occurrence, such as indicators for risk based inspections; and d) Record event attributes to facilitate quantification of CCF frequencies when so decided by the Project Working Group. The ICDE Project is envisaged to comprise all possible events of interest, including both complete and partial ICDE events. The ICDE Project will cover the key components of the main safety systems. Presently, the components listed below are included in the ICDE Project. Data have been collected for the six first components in the list: Centrifugal pumps, Diesel generators, Motor operated valves, Safety relief valves/power operated relief valves, Check valves, Batteries, Level measurement, Breakers, Control rod drive assemblies. Others will be added to this list later on. In this component coding guidelines, explanations on the ICDE General coding format are given. The guide reflects present experience with the data format and with the collected data. Further interpretations and clarifications will be added, should they become necessary. For each component analysed in the ICDE project, separate coding guidance is provided in the appendices

  18. Evaluating Open-Source Full-Text Search Engines for Matching ICD-10 Codes.

    Science.gov (United States)

    Jurcău, Daniel-Alexandru; Stoicu-Tivadar, Vasile

    2016-01-01

    This research presents the results of evaluating multiple free, open-source engines on matching ICD-10 diagnostic codes via full-text searches. The study investigates what it takes to get an accurate match when searching for a specific diagnostic code. For each code the evaluation starts by extracting the words that make up its text and continues with building full-text search queries from the combinations of these words. The queries are then run against all the ICD-10 codes until a match indicates the code in question as a match with the highest relative score. This method identifies the minimum number of words that must be provided in order for the search engines choose the desired entry. The engines analyzed include a popular Java-based full-text search engine, a lightweight engine written in JavaScript which can even execute on the user's browser, and two popular open-source relational database management systems.

  19. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation.

    Science.gov (United States)

    Dyers, Robin; Ward, Grant; Du Plooy, Shane; Fourie, Stephanus; Evans, Juliet; Mahomed, Hassan

    2017-05-24

    The proposed National Health Insurance policy for South Africa (SA) requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD) codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2) adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  20. Validity of Principal Diagnoses in Discharge Summaries and ICD-10 Coding Assessments Based on National Health Data of Thailand.

    Science.gov (United States)

    Sukanya, Chongthawonsatid

    2017-10-01

    This study examined the validity of the principal diagnoses on discharge summaries and coding assessments. Data were collected from the National Health Security Office (NHSO) of Thailand in 2015. In total, 118,971 medical records were audited. The sample was drawn from government hospitals and private hospitals covered by the Universal Coverage Scheme in Thailand. Hospitals and cases were selected using NHSO criteria. The validity of the principal diagnoses listed in the "Summary and Coding Assessment" forms was established by comparing data from the discharge summaries with data obtained from medical record reviews, and additionally, by comparing data from the coding assessments with data in the computerized ICD (the data base used for reimbursement-purposes). The summary assessments had low sensitivities (7.3%-37.9%), high specificities (97.2%-99.8%), low positive predictive values (9.2%-60.7%), and high negative predictive values (95.9%-99.3%). The coding assessments had low sensitivities (31.1%-69.4%), high specificities (99.0%-99.9%), moderate positive predictive values (43.8%-89.0%), and high negative predictive values (97.3%-99.5%). The discharge summaries and codings often contained mistakes, particularly the categories "Endocrine, nutritional, and metabolic diseases", "Symptoms, signs, and abnormal clinical and laboratory findings not elsewhere classified", "Factors influencing health status and contact with health services", and "Injury, poisoning, and certain other consequences of external causes". The validity of the principal diagnoses on the summary and coding assessment forms was found to be low. The training of physicians and coders must be strengthened to improve the validity of discharge summaries and codings.

  1. International Common Cause Failure Data Exchange (ICDE). General Coding Guidelines - Updated Version, October 2011

    International Nuclear Information System (INIS)

    Johanson, Gunnar; Werner, Wolfgang; Capote, Marina Concepcion; Kreuser, Albert

    2012-01-01

    Several OECD/NEA member countries have established the International Common-Cause Failure Data Exchange Project ('ICDE Project') to encourage multilateral cooperation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The objectives of the ICDE Project are to: a) Collect and analyse CCF events over the long term so as to better understand such events, their causes, and their prevention. b) Generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences. c) Establish a mechanism for the efficient feedback of experience gained in connection with CCF phenomena, including the development of defenses against their occurrence, such as indicators for risk based inspections. d) Record event attributes to facilitate quantification of CCF frequencies when so decided by the Project Working Group. The ICDE Project is envisaged to comprise all possible events of interest, including both complete and partial ICDE events. The ICDE Project will cover the key components of the main safety systems. Presently, the components listed below are included in the ICDE Project. Data have been collected for the six first components in the list: Centrifugal pumps, Diesel generators, Motor operated valves, Safety relief valves/power operated relief valves, Check valves, Batteries, Level measurement, Breakers, Control rod drive assemblies. Others will be added to this list later on. In this component coding guidelines, explanations on the ICDE general coding format are given. The guide reflects present experience with the data format and with the collected data. Further interpretations and clarifications will be added, should they become necessary. For each component analysed in the ICDE project, separate coding guidance is provided in the appendices ICDECG 01-06, specifying details relevant to the respective components

  2. 77 FR 40620 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) - Extension Date for...

    Science.gov (United States)

    2012-07-10

    ... on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) -- Extension Date for Nominations AGENCY... AHRQ QIs, please visit the AHRQ Web site at http://www.QUALITYindicators.AHRQ.gov . Specifically, each Workgroup on ICD-10-CM/PCS Conversion of Quality Indicators will consist of: --At least three individuals...

  3. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation

    Directory of Open Access Journals (Sweden)

    Robin Dyers

    2017-06-01

    Full Text Available Background. The proposed National Health Insurance policy for South Africa (SA requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. Objective. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. Methods. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. Results. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2 adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. Conclusion. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  4. Quality improvement of International Classification of Diseases, 9th revision, diagnosis coding in radiation oncology: single-institution prospective study at University of California, San Francisco.

    Science.gov (United States)

    Chen, Chien P; Braunstein, Steve; Mourad, Michelle; Hsu, I-Chow J; Haas-Kogan, Daphne; Roach, Mack; Fogh, Shannon E

    2015-01-01

    Accurate International Classification of Diseases (ICD) diagnosis coding is critical for patient care, billing purposes, and research endeavors. In this single-institution study, we evaluated our baseline ICD-9 (9th revision) diagnosis coding accuracy, identified the most common errors contributing to inaccurate coding, and implemented a multimodality strategy to improve radiation oncology coding. We prospectively studied ICD-9 coding accuracy in our radiation therapy--specific electronic medical record system. Baseline ICD-9 coding accuracy was obtained from chart review targeting ICD-9 coding accuracy of all patients treated at our institution between March and June of 2010. To improve performance an educational session highlighted common coding errors, and a user-friendly software tool, RadOnc ICD Search, version 1.0, for coding radiation oncology specific diagnoses was implemented. We then prospectively analyzed ICD-9 coding accuracy for all patients treated from July 2010 to June 2011, with the goal of maintaining 80% or higher coding accuracy. Data on coding accuracy were analyzed and fed back monthly to individual providers. Baseline coding accuracy for physicians was 463 of 661 (70%) cases. Only 46% of physicians had coding accuracy above 80%. The most common errors involved metastatic cases, whereby primary or secondary site ICD-9 codes were either incorrect or missing, and special procedures such as stereotactic radiosurgery cases. After implementing our project, overall coding accuracy rose to 92% (range, 86%-96%). The median accuracy for all physicians was 93% (range, 77%-100%) with only 1 attending having accuracy below 80%. Incorrect primary and secondary ICD-9 codes in metastatic cases showed the most significant improvement (10% vs 2% after intervention). Identifying common coding errors and implementing both education and systems changes led to significantly improved coding accuracy. This quality assurance project highlights the potential problem

  5. [Coding in general practice-Will the ICD-11 be a step forward?

    Science.gov (United States)

    Kühlein, Thomas; Virtanen, Martti; Claus, Christoph; Popert, Uwe; van Boven, Kees

    2018-07-01

    Primary care physicians in Germany don't benefit from coding diagnoses-they are coding for the needs of others. For coding, they mostly are using either the thesaurus of the German Institute of Medical Documentation and Information (DIMDI) or self-made cheat-sheets. Coding quality is low but seems to be sufficient for the main use case of the resulting data, which is the morbidity adjusted risk compensation scheme that distributes financial resources between the many German health insurance companies.Neither the International Classification of Diseases and Health Related Problems (ICD-10) nor the German thesaurus as an interface terminology are adequate for coding in primary care. The ICD-11 itself will not recognizably be a step forward from the perspective of primary care. At least the browser database format will be advantageous. An implementation into the 182 different electronic health records (EHR) on the German market would probably standardize the coding process and make code finding easier. This method of coding would still be more cumbersome than the current coding with self-made cheat-sheets.The first steps towards a useful official cheat-sheet for primary care have been taken, awaiting implementation and evaluation. The International Classification of Primary Care (ICPC-2) already provides an adequate classification standard for primary care that can also be used in combination with ICD-10. A new version of ICPC (ICPC-3) is under development. As the ICPC-2 has already been integrated into the foundation layer of ICD-11 it might easily become the future standard for coding in primary care. Improving communication between the different EHR would make taking over codes from other healthcare providers possible. Another opportunity to improve the coding quality might be creating use cases for the resulting data for the primary care physicians themselves.

  6. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data

    Science.gov (United States)

    Jolley, Rachel J; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-01-01

    Objective Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. Setting and participants All adults (aged ≥18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Research design Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Measures Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. Conclusions This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. PMID:26700284

  7. Training and support to improve ICD coding quality: A controlled ...

    African Journals Online (AJOL)

    [1] In response to this challenge, the Western Cape Government: Health (WCGH) ... commit to costly, time-consuming accredited ICD coding courses, although ..... being blinded to the retrospective 'assignment' of patients to the intervention ...

  8. [Data coding in the Israeli healthcare system - do choices provide the answers to our system's needs?].

    Science.gov (United States)

    Zelingher, Julian; Ash, Nachman

    2013-05-01

    The IsraeLi healthcare system has undergone major processes for the adoption of health information technologies (HIT), and enjoys high Levels of utilization in hospital and ambulatory care. Coding is an essential infrastructure component of HIT, and ts purpose is to represent data in a simplified and common format, enhancing its manipulation by digital systems. Proper coding of data enables efficient identification, storage, retrieval and communication of data. UtiLization of uniform coding systems by different organizations enables data interoperability between them, facilitating communication and integrating data elements originating in different information systems from various organizations. Current needs in Israel for heaLth data coding include recording and reporting of diagnoses for hospitalized patients, outpatients and visitors of the Emergency Department, coding of procedures and operations, coding of pathology findings, reporting of discharge diagnoses and causes of death, billing codes, organizational data warehouses and national registries. New national projects for cLinicaL data integration, obligatory reporting of quality indicators and new Ministry of Health (MOH) requirements for HIT necessitate a high Level of interoperability that can be achieved only through the adoption of uniform coding. Additional pressures were introduced by the USA decision to stop the maintenance of the ICD-9-CM codes that are also used by Israeli healthcare, and the adoption of ICD-10-C and ICD-10-PCS as the main coding system for billing purpose. The USA has also mandated utilization of SNOMED-CT as the coding terminology for the ELectronic Health Record problem list, and for reporting quality indicators to the CMS. Hence, the Israeli MOH has recently decided that discharge diagnoses will be reported using ICD-10-CM codes, and SNOMED-CT will be used to code the cLinical information in the EHR. We reviewed the characteristics, strengths and weaknesses of these two coding

  9. Identifying clinically disruptive International Classification of Diseases 10th Revision Clinical Modification conversions to mitigate financial costs using an online tool.

    Science.gov (United States)

    Venepalli, Neeta K; Qamruzzaman, Yusuf; Li, Jianrong John; Lussier, Yves A; Boyd, Andrew D

    2014-03-01

    To quantify coding ambiguity in International Classification of Diseases Ninth Revision Clinical Modification conversions (ICD-9-CM) to ICD-10-CM mappings for hematology-oncology diagnoses within an Illinois Medicaid database and an academic cancer center database (University of Illinois Cancer Center [UICC]) with the goal of anticipating challenges during ICD-10-CM transition. One data set of ICD-9-CM diagnosis codes came from the 2010 Illinois Department of Medicaid, filtered for diagnoses generated by hematology-oncology providers. The other data set of ICD-9-CM diagnosis codes came from UICC. Using a translational methodology via the Motif Web portal ICD-9-CM conversion tool, ICD-9-CM to ICD-10-CM code conversions were graphically mapped and evaluated for clinical loss of information. The transition to ICD-10-CM led to significant information loss, affecting 8% of total Medicaid codes and 1% of UICC codes; 39 ICD-9-CM codes with information loss accounted for 2.9% of total Medicaid reimbursements and 5.3% of UICC billing charges. Prior work stated hematology-oncology would be the least affected medical specialty. However, information loss affecting 5% of billing costs could evaporate the operating margin of a practice. By identifying codes at risk for complex transitions, the analytic tools described can be replicated for oncology practices to forecast areas requiring additional training and resource allocation. In summary, complex transitions and diagnosis codes associated with information loss within clinical oncology require additional attention during the transition to ICD-10-CM.

  10. Transition to international classification of disease version 10, clinical modification: the impact on internal medicine and internal medicine subspecialties.

    Science.gov (United States)

    Caskey, Rachel N; Abutahoun, Angelos; Polick, Anne; Barnes, Michelle; Srivastava, Pavan; Boyd, Andrew D

    2018-05-04

    The US health care system uses diagnostic codes for billing and reimbursement as well as quality assessment and measuring clinical outcomes. The US transitioned to the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) on October, 2015. Little is known about the impact of ICD-10-CM on internal medicine and medicine subspecialists. We used a state-wide data set from Illinois Medicaid specified for Internal Medicine providers and subspecialists. A total of 3191 ICD-9-CM codes were used for 51,078 patient encounters, for a total cost of US $26,022,022 for all internal medicine. We categorized all of the ICD-9-CM codes based on the complexity of mapping to ICD-10-CM as codes with complex mapping could result in billing or administrative errors during the transition. Codes found to have complex mapping and frequently used codes (n = 295) were analyzed for clinical accuracy of mapping to ICD-10-CM. Each subspecialty was analyzed for complexity of codes used and proportion of reimbursement associated with complex codes. Twenty-five percent of internal medicine codes have convoluted mapping to ICD-10-CM, which represent 22% of Illinois Medicaid patients, and 30% of reimbursements. Rheumatology and Endocrinology had the greatest proportion of visits and reimbursement associated with complex codes. We found 14.5% of ICD-9-CM codes used by internists, when mapped to ICD-10-CM, resulted in potential clinical inaccuracies. We identified that 43% of diagnostic codes evaluated and used by internists and that account for 14% of internal medicine reimbursements are associated with codes which could result in administrative errors.

  11. Using Administrative Mental Health Indicators in Heart Failure Outcomes Research: Comparison of Clinical Records and International Classification of Disease Coding.

    Science.gov (United States)

    Bender, Miriam; Smith, Tyler C

    2016-01-01

    Use of mental indication in health outcomes research is of growing interest to researchers. This study, as part of a larger research program, quantified agreement between administrative International Classification of Disease (ICD-9) coding for, and "gold standard" clinician documentation of, mental health issues (MHIs) in hospitalized heart failure (HF) patients to determine the validity of mental health administrative data for use in HF outcomes research. A 13% random sample (n = 504) was selected from all unique patients (n = 3,769) hospitalized with a primary HF diagnosis at 4 San Diego County community hospitals during 2009-2012. MHI was defined as ICD-9 discharge diagnostic coding 290-319. Records were audited for clinician documentation of MHI. A total of 43% (n = 216) had mental health clinician documentation; 33% (n = 164) had ICD-9 coding for MHI. ICD-9 code bundle 290-319 had 0.70 sensitivity, 0.97 specificity, and kappa 0.69 (95% confidence interval 0.61-0.79). More specific ICD-9 MHI code bundles had kappas ranging from 0.44 to 0.82 and sensitivities ranging from 42% to 82%. Agreement between ICD-9 coding and clinician documentation for a broadly defined MHI is substantial, and can validly "rule in" MHI for hospitalized patients with heart failure. More specific MHI code bundles had fair to almost perfect agreement, with a wide range of sensitivities for identifying patients with an MHI. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Impact of the Transition to ICD-10 on Medicare Payment

    Data.gov (United States)

    U.S. Department of Health & Human Services — Although the transition from the ICD-9-CM to the ICD-10 version of MS-DRGs resulted in 1.68 percent of the patients being assigned to a different MS-DRG, payment...

  13. Electronic Health Record Based Algorithm to Identify Patients with Autism Spectrum Disorder.

    Directory of Open Access Journals (Sweden)

    Todd Lingren

    Full Text Available Cohort selection is challenging for large-scale electronic health record (EHR analyses, as International Classification of Diseases 9th edition (ICD-9 diagnostic codes are notoriously unreliable disease predictors. Our objective was to develop, evaluate, and validate an automated algorithm for determining an Autism Spectrum Disorder (ASD patient cohort from EHR. We demonstrate its utility via the largest investigation to date of the co-occurrence patterns of medical comorbidities in ASD.We extracted ICD-9 codes and concepts derived from the clinical notes. A gold standard patient set was labeled by clinicians at Boston Children's Hospital (BCH (N = 150 and Cincinnati Children's Hospital and Medical Center (CCHMC (N = 152. Two algorithms were created: (1 rule-based implementing the ASD criteria from Diagnostic and Statistical Manual of Mental Diseases 4th edition, (2 predictive classifier. The positive predictive values (PPV achieved by these algorithms were compared to an ICD-9 code baseline. We clustered the patients based on grouped ICD-9 codes and evaluated subgroups.The rule-based algorithm produced the best PPV: (a BCH: 0.885 vs. 0.273 (baseline; (b CCHMC: 0.840 vs. 0.645 (baseline; (c combined: 0.864 vs. 0.460 (baseline. A validation at Children's Hospital of Philadelphia yielded 0.848 (PPV. Clustering analyses of comorbidities on the three-site large cohort (N = 20,658 ASD patients identified psychiatric, developmental, and seizure disorder clusters.In a large cross-institutional cohort, co-occurrence patterns of comorbidities in ASDs provide further hypothetical evidence for distinct courses in ASD. The proposed automated algorithms for cohort selection open avenues for other large-scale EHR studies and individualized treatment of ASD.

  14. Breathing (and Coding?) a Bit Easier: Changes to International Classification of Disease Coding for Pulmonary Hypertension.

    Science.gov (United States)

    Mathai, Stephen C; Mathew, Sherin

    2018-04-20

    International Classification of Disease (ICD) coding system is broadly utilized by healthcare providers, hospitals, healthcare payers, and governments to track health trends and statistics at the global, national, and local levels and to provide a reimbursement framework for medical care based upon diagnosis and severity of illness. The current iteration of the ICD system, ICD-10, was implemented in 2015. While many changes to the prior ICD-9 system were included in the ICD-10 system, the newer revision failed to adequately reflect advances in the clinical classification of certain diseases such as pulmonary hypertension (PH). Recently, a proposal to modify the ICD-10 codes for PH was considered and ultimately adopted for inclusion as updates to ICD-10 coding system. While these revisions better reflect the current clinical classification of PH, in the future, further changes should be considered to improve the accuracy and ease of coding for all forms of PH. Copyright © 2018. Published by Elsevier Inc.

  15. The Utility and Challenges of Using ICD Codes in Child Maltreatment Research: A Review of Existing Literature

    Science.gov (United States)

    Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten

    2009-01-01

    Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…

  16. Underestimated prevalence of heart failure in hospital inpatients: a comparison of ICD codes and discharge letter information.

    Science.gov (United States)

    Kaspar, Mathias; Fette, Georg; Güder, Gülmisal; Seidlmayer, Lea; Ertl, Maximilian; Dietrich, Georg; Greger, Helmut; Puppe, Frank; Störk, Stefan

    2018-04-17

    Heart failure is the predominant cause of hospitalization and amongst the leading causes of death in Germany. However, accurate estimates of prevalence and incidence are lacking. Reported figures originating from different information sources are compromised by factors like economic reasons or documentation quality. We implemented a clinical data warehouse that integrates various information sources (structured parameters, plain text, data extracted by natural language processing) and enables reliable approximations to the real number of heart failure patients. Performance of ICD-based diagnosis in detecting heart failure was compared across the years 2000-2015 with (a) advanced definitions based on algorithms that integrate various sources of the hospital information system, and (b) a physician-based reference standard. Applying these methods for detecting heart failure in inpatients revealed that relying on ICD codes resulted in a marked underestimation of the true prevalence of heart failure, ranging from 44% in the validation dataset to 55% (single year) and 31% (all years) in the overall analysis. Percentages changed over the years, indicating secular changes in coding practice and efficiency. Performance was markedly improved using search and permutation algorithms from the initial expert-specified query (F1 score of 81%) to the computer-optimized query (F1 score of 86%) or, alternatively, optimizing precision or sensitivity depending on the search objective. Estimating prevalence of heart failure using ICD codes as the sole data source yielded unreliable results. Diagnostic accuracy was markedly improved using dedicated search algorithms. Our approach may be transferred to other hospital information systems.

  17. Use of the Spine Adverse Events Severity System (SAVES) in patients with traumatic spinal cord injury. A comparison with institutional ICD-10 coding for the identification of acute care adverse events.

    Science.gov (United States)

    Street, J T; Thorogood, N P; Cheung, A; Noonan, V K; Chen, J; Fisher, C G; Dvorak, M F

    2013-06-01

    Observational cohort comparison. To compare the previously validated Spine Adverse Events Severity system (SAVES) with International Classification of Diseases, Tenth Revision codes (ICD-10) codes for identifying adverse events (AEs) in patients with traumatic spinal cord injury (TSCI). Quaternary Care Spine Program. Patients discharged between 2006 and 2010 were identified from our prospective registry. Two consecutive cohorts were created based on the system used to record acute care AEs; one used ICD-10 coding by hospital coders and the other used SAVES data prospectively collected by a multidisciplinary clinical team. The ICD-10 codes were appropriately mapped to the SAVES. There were 212 patients in the ICD-10 cohort and 173 patients in the SAVES cohort. Analyses were adjusted to account for the different sample sizes, and the two cohorts were comparable based on age, gender and motor score. The SAVES system identified twice as many AEs per person as ICD-10 coding. Fifteen unique AEs were more reliably identified using SAVES, including neuropathic pain (32 × more; Ppatient age and severity of paralysis were more reliably correlated to AEs collected through SAVES than ICD-10. Implementation of the SAVES system for patients with TSCI captured more individuals experiencing AEs and more AEs per person compared with ICD-10 codes. This study demonstrates the utility of prospectively collecting AE data using validated tools.

  18. Quantifying medical student clinical experiences via an ICD Code Logging App.

    Science.gov (United States)

    Rawlins, Fred; Sumpter, Cameron; Sutphin, Dean; Garner, Harold R

    2018-03-01

    The logging of ICD Diagnostic, Procedure and Drug codes is one means of tracking the experience of medical students' clinical rotations. The goal is to create a web-based computer and mobile application to track the progress of trainees, monitor the effectiveness of their training locations and be a means of sampling public health status. We have developed a web-based app in which medical trainees make entries via a simple and quick interface optimized for both mobile devices and personal computers. For each patient interaction, users enter ICD diagnostic, procedure, and drug codes via a hierarchical or search entry interface, as well as patient demographics (age range and gender, but no personal identifiers), and free-text notes. Users and administrators can review and edit input via a series of output interfaces. The user interface and back-end database are provided via dual redundant failover Linux servers. Students master the interface in ten minutes, and thereafter complete entries in less than one minute. Five hundred-forty 3rd year VCOM students each averaged 100 entries in the first four week clinical rotation. Data accumulated in various Appalachian clinics and Central American medical mission trips has demonstrated the public health surveillance utility of the application. PC and mobile apps can be used to collect medical trainee experience in real time or near real-time, quickly, and efficiently. This system has collected 75,596 entries to date, less than 2% of trainees have needed assistance to become proficient, and medical school administrators are using the various summaries to evaluate students and compare different rotation sites. Copyright © 2017. Published by Elsevier B.V.

  19. Transparent ICD and DRG coding using information technology: linking and associating information sources with the eXtensible Markup Language.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Dudeck, Joachim

    2003-01-01

    With the introduction of ICD-10 as the standard for diagnostics, it becomes necessary to develop an electronic representation of its complete content, inherent semantics, and coding rules. The authors' design relates to the current efforts by the CEN/TC 251 to establish a European standard for hierarchical classification systems in health care. The authors have developed an electronic representation of ICD-10 with the eXtensible Markup Language (XML) that facilitates integration into current information systems and coding software, taking different languages and versions into account. In this context, XML provides a complete processing framework of related technologies and standard tools that helps develop interoperable applications. XML provides semantic markup. It allows domain-specific definition of tags and hierarchical document structure. The idea of linking and thus combining information from different sources is a valuable feature of XML. In addition, XML topic maps are used to describe relationships between different sources, or "semantically associated" parts of these sources. The issue of achieving a standardized medical vocabulary becomes more and more important with the stepwise implementation of diagnostically related groups, for example. The aim of the authors' work is to provide a transparent and open infrastructure that can be used to support clinical coding and to develop further software applications. The authors are assuming that a comprehensive representation of the content, structure, inherent semantics, and layout of medical classification systems can be achieved through a document-oriented approach.

  20. Improved accuracy of co-morbidity coding over time after the introduction of ICD-10 administrative data.

    Science.gov (United States)

    Januel, Jean-Marie; Luthi, Jean-Christophe; Quan, Hude; Borst, François; Taffé, Patrick; Ghali, William A; Burnand, Bernard

    2011-08-18

    Co-morbidity information derived from administrative data needs to be validated to allow its regular use. We assessed evolution in the accuracy of coding for Charlson and Elixhauser co-morbidities at three time points over a 5-year period, following the introduction of the International Classification of Diseases, 10th Revision (ICD-10), coding of hospital discharges. Cross-sectional time trend evaluation study of coding accuracy using hospital chart data of 3'499 randomly selected patients who were discharged in 1999, 2001 and 2003, from two teaching and one non-teaching hospital in Switzerland. We measured sensitivity, positive predictive and Kappa values for agreement between administrative data coded with ICD-10 and chart data as the 'reference standard' for recording 36 co-morbidities. For the 17 the Charlson co-morbidities, the sensitivity - median (min-max) - was 36.5% (17.4-64.1) in 1999, 42.5% (22.2-64.6) in 2001 and 42.8% (8.4-75.6) in 2003. For the 29 Elixhauser co-morbidities, the sensitivity was 34.2% (1.9-64.1) in 1999, 38.6% (10.5-66.5) in 2001 and 41.6% (5.1-76.5) in 2003. Between 1999 and 2003, sensitivity estimates increased for 30 co-morbidities and decreased for 6 co-morbidities. The increase in sensitivities was statistically significant for six conditions and the decrease significant for one. Kappa values were increased for 29 co-morbidities and decreased for seven. Accuracy of administrative data in recording clinical conditions improved slightly between 1999 and 2003. These findings are of relevance to all jurisdictions introducing new coding systems, because they demonstrate a phenomenon of improved administrative data accuracy that may relate to a coding 'learning curve' with the new coding system.

  1. Concept Mapping zur Unterstützung der differentialdiagnostischen Hypothesenbildung im fallbasierten Online-Lernsystem CASUS: Qualitative Verbesserung der Diagnosefindung durch ICD-10 Kodierung [Concept mapping for supporting the differential diagnostic generation of hypotheses in the case-based online learning system CASUS: Qualitative improvement of dagnostic performance through ICD-10 coding

    Directory of Open Access Journals (Sweden)

    Kernt, Marcus

    2008-08-01

    Full Text Available [english] Introduction: Concept mapping tools have long been established in medical education as an aid for visualizing learning processes in computer-based programs. The case-based learning system CASUS with its mapping tool for visualizing the differential diagnostic reasoning process is an example. It was shown that such tools are well accepted by users and lead to an increased number of diagnostic hypotheses being visualized as maps. However, there is scarce evidence on the quality of user-generated diagnostic hypotheses. This study examines the quality of diagnostic hypotheses obtained with CASUS and whether the quality can be improved through ICD-10 coding as compared with an expert’s solution. Methods: We randomized 192 third-year medical students at the University of Munich into two groups. The students worked in groups of two on one computer. Group A was asked to code their diagnostic hypotheses with an ICD-10 coding browser before entering them into the mapping tool. Group B generated their hypotheses without prior ICD-10 coding. The differential diagnostic reasoning visualizations were analyzed quantitatively and qualitatively. An expert solution was used as reference. Results: Eighty-seven differential diagnoses were evaluated. Group A, using ICD-10 coding, made the correct and precise diagnosis of malaria tropica significantly more often than Group B (p < 0.05. For additional alternative diagnostic hypotheses, no quantitative or qualitative differences were detected. Conclusions: ICD-10 coding in connection with a mapping tool supporting the diagnostic reasoning process improved the accuracy of diagnostic performance in third-year medical students in the case of malaria tropica. [german] Einleitung: Der Einsatz von Concept-Mapping-Tools in computergestützten Lernprogrammen ist in der medizinischen Ausbildung etabliert: Es konnte gezeigt werden, dass diese Werkzeuge zur Visualisierung von Differentialdiagnosen vom Anwender

  2. Using Chief Complaint in Addition to Diagnosis Codes to Identify Falls in the Emergency Department.

    Science.gov (United States)

    Patterson, Brian W; Smith, Maureen A; Repplinger, Michael D; Pulia, Michael S; Svenson, James E; Kim, Michael K; Shah, Manish N

    2017-09-01

    To compare incidence of falls in an emergency department (ED) cohort using a traditional International Classification of Diseases, Ninth Revision (ICD-9) code-based scheme and an expanded definition that included chief complaint information and to examine the clinical characteristics of visits "missed" in the ICD-9-based scheme. Retrospective electronic record review. Academic medical center ED. Individuals aged 65 and older seen in the ED between January 1, 2013, and September 30, 2015. Two fall definitions were applied (individually and together) to the cohort: an ICD-9-based definition and a chief complaint definition. Admission rates and 30-day mortality (per encounter) were measured for each definition. Twenty-three thousand eight hundred eighty older adult visits occurred during the study period. Using the most-inclusive definition (ICD-9 code or chief complaint indicating a fall), 4,363 visits (18%) were fall related. Of these visits, 3,506 (80%) met the ICD-9 definition for a fall-related visit, and 2,664 (61%) met the chief complaint definition. Of visits meeting the chief complaint definition, 857 (19.6%) were missed when applying the ICD-9 definition alone. Encounters missed using the ICD-9 definition were less likely to lead to an admission (42.9%, 95% confidence interval (CI) = 39.7-46.3%) than those identified (54.4%, 95% CI = 52.7-56.0%). Identifying individuals in the ED who have fallen based on diagnosis codes underestimates the true burden of falls. Individuals missed according to the code-based definition were less likely to have been admitted than those who were captured. These findings call attention to the value of using chief complaint information to identify individuals who have fallen in the ED-for research, clinical care, or policy reasons. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  3. [Cause-of-death statistics and ICD, quo vadis?

    Science.gov (United States)

    Eckert, Olaf; Vogel, Ulrich

    2018-07-01

    The International Statistical Classification of Diseases and Related Health Problems (ICD) is the worldwide binding standard for generating underlying cause-of-death statistics. What are the effects of former revisions of the ICD on underlying cause-of-death statistics and which opportunities and challenges are becoming apparent in a possible transition process from ICD-10 to ICD-11?This article presents the calculation of the exploitation grade of ICD-9 and ICD-10 in the German cause-of-death statistics and quality of documentation. Approximately 67,000 anonymized German death certificates are processed by Iris/MUSE and official German cause-of-death statistics are analyzed.In addition to substantial changes in the exploitation grade in the transition from ICD-9 to ICD-10, regional effects become visible. The rate of so-called "ill-defined" conditions exceeds 10%.Despite substantial improvement of ICD revisions there are long-known deficits in the coroner's inquest, filling death certificates and quality of coding. To make better use of the ICD as a methodological framework for mortality statistics and health reporting in Germany, the following measures are necessary: 1. General use of Iris/MUSE, 2. Establishing multiple underlying cause-of-death statistics, 3. Introduction of an electronic death certificate, 4. Improvement of the medical assessment of cause of death.Within short time the WHO will release the 11th revision of the ICD that will provide additional opportunities for the development of underlying cause-of-death statistics and their use in science, public health and politics. A coordinated effort including participants in the process and users is necessary to meet the related challenges.

  4. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    Science.gov (United States)

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  5. Are central hospitals ready for National Health Insurance? ICD ...

    African Journals Online (AJOL)

    ICD coding quality from an electronic patient discharge record for clinicians. ... RE Dyers, J Evans, GA Ward, S du Plooy, H Mahomed ... After 6 months, the quality of ICD codes was determined by comparing ICD code descriptors with medical concepts in a random sample of original patient records selected over a 6-week ...

  6. Improving discharge data fidelity for use in large administrative databases.

    Science.gov (United States)

    Gologorsky, Yakov; Knightly, John J; Lu, Yi; Chi, John H; Groff, Michael W

    2014-06-01

    Large administrative databases have assumed a major role in population-based studies examining health care delivery. Lumbar fusion surgeries specifically have been scrutinized for rising rates coupled with ill-defined indications for fusion such as stenosis and spondylosis. Administrative databases classify cases with the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM). The ICD-9-CM discharge codes are not designated by surgeons, but rather are assigned by trained hospital medical coders. It is unclear how accurately they capture the surgeon's indication for fusion. The authors first sought to compare the ICD-9-CM code(s) assigned by the medical coder according to the surgeon's indication based on a review of the medical chart, and then to elucidate barriers to data fidelity. A retrospective review was undertaken of all lumbar fusions performed in the Department of Neurosurgery at the authors' institution between August 1, 2011, and August 31, 2013. Based on this review, the indication for fusion in each case was categorized as follows: spondylolisthesis, deformity, tumor, infection, nonpathological fracture, pseudarthrosis, adjacent-level degeneration, stenosis, degenerative disc disease, or disc herniation. These surgeon diagnoses were compared with the primary ICD-9-CM codes that were generated by the medical coders and submitted to administrative databases. A follow-up interview with the hospital's coders and coding manager was undertaken to review causes of error and suggestions for future improvement in data fidelity. There were 178 lumbar fusion operations performed in the course of 170 hospital admissions. There were 44 hospitalizations in which fusion was performed for tumor, infection, or nonpathological fracture. Of these, the primary diagnosis matched the surgical indication for fusion in 98% of cases. The remaining 126 hospitalizations were for degenerative diseases, and of these, the primary ICD-9-CM

  7. Speaking the same language: underestimating financial impact when using diagnosis-related group versus ICD-9-based definitions for trauma inclusion criteria.

    Science.gov (United States)

    Deppe, Sharon; Truax, Christopher B; Opalek, Judy M; Santanello, Steven A

    2009-04-01

    Hospital accounting methods use diagnosis-related group (DRG) data to identify patients and derive financial analyses and reports. The National Trauma Data Bank and trauma programs identify patients with trauma by International Classification of Diseases, Ninth Edition (ICD-9)-based definitions for inclusion criteria. These differing methods of identifying patients result in economic reports that vary significantly and fail to accurately identify the financial impact of trauma services. Routine financial data were collected for patients admitted to our Trauma Service from July 1, 2005 to June 30, 2006 using two methods of identifying the cases; by trauma DRGs and by trauma registry database inclusion criteria. The resulting data were compared and stratified to define the financial impact on hospital charges, reimbursement, costs, contribution to margin, downstream revenue, and estimated profit or loss. The results also defined the impact on supporting services, market share and total revenue from trauma admissions, return visits, discharged trauma alerts, and consultations. A total of 3,070 patients were identified by the trauma registry as meeting ICD-9 inclusion criteria. Trauma-associated DRGs accounted for 871 of the 3,070 admissions. The DRG-driven data set demonstrated an estimated profit of $800,000 dollars; the ICD-9 data set revealed an estimated 4.8 million dollar profit, increased our market share, and showed substantial revenue generated for other hospital service lines. Trauma DRGs fail to account for most trauma admissions. Financial data derived from DRG definitions significantly underestimate the trauma service line's financial contribution to hospital economics. Accurately identifying patients with trauma based on trauma database inclusion criteria better defines the business of trauma.

  8. Administrative database concerns: accuracy of International Classification of Diseases, Ninth Revision coding is poor for preoperative anemia in patients undergoing spinal fusion.

    Science.gov (United States)

    Golinvaux, Nicholas S; Bohl, Daniel D; Basques, Bryce A; Grauer, Jonathan N

    2014-11-15

    Cross-sectional study. To objectively evaluate the ability of International Classification of Diseases, Ninth Revision (ICD-9) codes, which are used as the foundation for administratively coded national databases, to identify preoperative anemia in patients undergoing spinal fusion. National database research in spine surgery continues to rise. However, the validity of studies based on administratively coded data, such as the Nationwide Inpatient Sample, are dependent on the accuracy of ICD-9 coding. Such coding has previously been found to have poor sensitivity to conditions such as obesity and infection. A cross-sectional study was performed at an academic medical center. Hospital-reported anemia ICD-9 codes (those used for administratively coded databases) were directly compared with the chart-documented preoperative hematocrits (true laboratory values). A patient was deemed to have preoperative anemia if the preoperative hematocrit was less than the lower end of the normal range (36.0% for females and 41.0% for males). The study included 260 patients. Of these, 37 patients (14.2%) were anemic; however, only 10 patients (3.8%) received an "anemia" ICD-9 code. Of the 10 patients coded as anemic, 7 were anemic by definition, whereas 3 were not, and thus were miscoded. This equates to an ICD-9 code sensitivity of 0.19, with a specificity of 0.99, and positive and negative predictive values of 0.70 and 0.88, respectively. This study uses preoperative anemia to demonstrate the potential inaccuracies of ICD-9 coding. These results have implications for publications using databases that are compiled from ICD-9 coding data. Furthermore, the findings of the current investigation raise concerns regarding the accuracy of additional comorbidities. Although administrative databases are powerful resources that provide large sample sizes, it is crucial that we further consider the quality of the data source relative to its intended purpose.

  9. Effect of delirium motoric subtypes on administrative documentation of delirium in the surgical intensive care unit.

    Science.gov (United States)

    Bui, Lan N; Pham, Vy P; Shirkey, Beverly A; Swan, Joshua T

    2017-06-01

    This study compares the proportions of surgical intensive care unit (ICU) patients with delirium detected using the Confusion Assessment Method for the ICU (CAM-ICU) who received administrative documentation for delirium using International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes, stratified by delirium motoric subtypes. This retrospective cohort study was conducted at a surgical ICU from 06/2012 to 05/2013. Delirium was assessed twice daily and was defined as having ≥1 positive CAM-ICU rating. Delirious patients were categorized into hyperactive/mixed and hypoactive subtypes using corresponding Richmond Agitation Sedation Scales. Administrative documentation of delirium was defined as having ≥1 of 32 unique ICD-9-CM codes. Proportions were compared using Pearson's Chi-square test. Of included patients, 40 % (423/1055) were diagnosed with delirium, and 17 % (183/1055) had an ICD-9-CM code for delirium. The sensitivity and specificity of ICD-9-CM codes for delirium were 36 and 95 %. ICD-9-CM codes for delirium were available for 42 % (95 % CI 35-48 %; 105/253) of patients with hyperactive/mixed delirium and 27 % (95 % CI 20-34 %; 46/170) of patients with hypoactive delirium (relative risk = 1.5; 95 % CI 1.2-2.0; p = 0.002). ICD-9-CM codes yielded a low sensitivity for identifying patients with CAM-ICU positive delirium and were more likely to identify hyperactive/mixed delirium compared with hypoactive delirium.

  10. Comparing Administrative and Clinical Data for Central Line Associated Blood Stream Infections in Pediatric Intensive Care Unit and Pediatric Cardiothoracic Intensive Care Unit

    Science.gov (United States)

    Bond, Jory; Issa, Mohamed; Nasrallah, Ali; Bahroloomi, Sheena; Blackwood, Roland A.

    2016-01-01

    Central line associated bloodstream infections (CLABSIs) are a frequent source of health complication for patients of all ages, including for patients in the pediatric intensive care unit (PICU) and Pediatric Cardiothoracic Intensive Care Unit (PCTU). Many hospitals, including the University of Michigan Health System, currently use the International Classification of Disease (ICD) coding system when coding for CLABSI. The purpose of this study was to determine the accuracy of coding for CLABSI infections with ICD-9CM codes in PICU and PCTU patients. A retrospective chart review was conducted for 75 PICU and PCTU patients with 90 events of hospital acquired central line infections at the University of Michigan Health System (from 2007-2011). The different variables examined in the chart review included the type of central line the patient had, the duration of the stay of the line, the type of organism infecting the patient, and the treatment the patient received. A review was conducted to assess if patients had received the proper ICD-9CM code for their hospital acquired infection. In addition, each patient chart was searched using Electronic Medical Record Search Engine to determine if any phrases that commonly referred to hospital acquired CLABSIs were present in their charts. Our review found that in most CLABSI cases the hospital’s administrative data diagnosis using ICD-9CM coding systems did not code for the CLABSI. Our results indicate a low sensitivity of 32% in the PICU and an even lower sensitivity of 12% in the PCTU. Using these results, we can conclude that the ICD-9CM coding system cannot be used for accurately defining hospital acquired CLABSIs in administrative data. With the new use of the ICD-10CM coding system, further research is needed to assess the effects of the ICD-10CM coding system on the accuracy of administrative data.

  11. Comparing administrative and clinical data for central line associated blood stream infections in Pediatric Intensive Care Unit and Pediatric Cardiothoracic Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Jory Bond

    2016-10-01

    Full Text Available Central line associated bloodstream infections (CLABSIs are a frequent source of health complication for patients of all ages, including for patients in the pediatric intensive care unit (PICU and Pediatric Cardiothoracic Intensive Care Unit (PCTU. Many hospitals, including the University of Michigan Health System, currently use the International Classification of Disease (ICD coding system when coding for CLABSI. The purpose of this study was to determine the accuracy of coding for CLABSI infections with ICD-9CM codes in PICU and PCTU patients. A retrospective chart review was conducted for 75 PICU and PCTU patients with 90 events of hospital acquired central line infections at the University of Michigan Health System (from 2007-2011. The different variables examined in the chart review included the type of central line the patient had, the duration of the stay of the line, the type of organism infecting the patient, and the treatment the patient received. A review was conducted to assess if patients had received the proper ICD-9CM code for their hospital acquired infection. In addition, each patient chart was searched using Electronic Medical Record Search Engine to determine if any phrases that commonly referred to hospital acquired CLABSIs were present in their charts. Our review found that in most CLABSI cases the hospital’s administrative data diagnosis using ICD-9CM coding systems did not code for the CLABSI. Our results indicate a low sensitivity of 32% in the PICU and an even lower sensitivity of 12% in the PCTU. Using these results, we can conclude that the ICD-9CM coding system cannot be used for accurately defining hospital acquired CLABSIs in administrative data. With the new use of the ICD- 10CM coding system, further research is needed to assess the effects of the ICD-10CM coding system on the accuracy of administrative data.

  12. A new coding system for metabolic disorders demonstrates gaps in the international disease classifications ICD-10 and SNOMED-CT, which can be barriers to genotype-phenotype data sharing.

    Science.gov (United States)

    Sollie, Annet; Sijmons, Rolf H; Lindhout, Dick; van der Ploeg, Ans T; Rubio Gozalbo, M Estela; Smit, G Peter A; Verheijen, Frans; Waterham, Hans R; van Weely, Sonja; Wijburg, Frits A; Wijburg, Rudolph; Visser, Gepke

    2013-07-01

    Data sharing is essential for a better understanding of genetic disorders. Good phenotype coding plays a key role in this process. Unfortunately, the two most widely used coding systems in medicine, ICD-10 and SNOMED-CT, lack information necessary for the detailed classification and annotation of rare and genetic disorders. This prevents the optimal registration of such patients in databases and thus data-sharing efforts. To improve care and to facilitate research for patients with metabolic disorders, we developed a new coding system for metabolic diseases with a dedicated group of clinical specialists. Next, we compared the resulting codes with those in ICD and SNOMED-CT. No matches were found in 76% of cases in ICD-10 and in 54% in SNOMED-CT. We conclude that there are sizable gaps in the SNOMED-CT and ICD coding systems for metabolic disorders. There may be similar gaps for other classes of rare and genetic disorders. We have demonstrated that expert groups can help in addressing such coding issues. Our coding system has been made available to the ICD and SNOMED-CT organizations as well as to the Orphanet and HPO organizations for further public application and updates will be published online (www.ddrmd.nl and www.cineas.org). © 2013 WILEY PERIODICALS, INC.

  13. Impact of procedure on the post-operative infection risk of patients after elective colon surgery.

    Science.gov (United States)

    Blitzer, David N; Davis, John M; Ahmed, Nasim; Kuo, Yen-Hong; Kuo, Yen-Liang

    2014-12-01

    Post-operative infection impacts the quality of patient care, prolongs the length of hospital stay, and utilizes more health care resources. The purpose of this study was to compare the rates of surgical site infection among three major surgical procedures for treating patients with colon pathology. The location of colon resection impacts the post-operative infection rate. A retrospective cohort study was conducted by using the 2006 Nationwide Inpatient Sample. Adult patients (age ≥18 yr) with colon diseases are the population of interest. The disease status and procedures were categorized according to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM). Patients with a primary diagnosis of diverticulosis of the colon without hemorrhage (ICD-9-CM codes: 562.11 and 562.12) or malignant neoplasm of the colon (ICD-9-CM codes: 153.x, where x represents the possible digits within this ICD-9-CM code category), with procedures of open and other right hemicolectomy (ORH; ICD-9-CM code: 45.73) or open and other left hemicolectomy (OLH; ICD-9-CM code: 45.75), or open and other sigmoidectomy (OS; ICD-9-CM code: 45.76) were included for this study. The primary measured outcome for the study was surgical site infection. There were an estimated 26,381 ORH procedures, 9,558 OLH procedures, and 31,656 OS procedures performed in 2006. There was a significant difference among procedures with respect to their age distributions (mean [standard error]: ORH vs. OLH vs. OS=70.5 [0.2] vs. 63.8 [0.3] vs. 59.5 [0.2] yr, pinfection rates: ORH vs. OLH vs. OS=2.9% vs. 5.6% vs. 4.9%, pinfection for OLH (AOR [95% CI]: 1.31 [1.04-1.64], p=0.02) compared with OS. Different sites of colon operations were associated with different risks of surgical site infections. Accordingly, appropriate pre-operative measures should address these differences.

  14. Truncation Depth Rule-of-Thumb for Convolutional Codes

    Science.gov (United States)

    Moision, Bruce

    2009-01-01

    In this innovation, it is shown that a commonly used rule of thumb (that the truncation depth of a convolutional code should be five times the memory length, m, of the code) is accurate only for rate 1/2 codes. In fact, the truncation depth should be 2.5 m/(1 - r), where r is the code rate. The accuracy of this new rule is demonstrated by tabulating the distance properties of a large set of known codes. This new rule was derived by bounding the losses due to truncation as a function of the code rate. With regard to particular codes, a good indicator of the required truncation depth is the path length at which all paths that diverge from a particular path have accumulated the minimum distance of the code. It is shown that the new rule of thumb provides an accurate prediction of this depth for codes of varying rates.

  15. Conceptual-driven classification for coding advise in health insurance reimbursement.

    Science.gov (United States)

    Li, Sheng-Tun; Chen, Chih-Chuan; Huang, Fernando

    2011-01-01

    With the non-stop increases in medical treatment fees, the economic survival of a hospital in Taiwan relies on the reimbursements received from the Bureau of National Health Insurance, which in turn depend on the accuracy and completeness of the content of the discharge summaries as well as the correctness of their International Classification of Diseases (ICD) codes. The purpose of this research is to enforce the entire disease classification framework by supporting disease classification specialists in the coding process. This study developed an ICD code advisory system (ICD-AS) that performed knowledge discovery from discharge summaries and suggested ICD codes. Natural language processing and information retrieval techniques based on Zipf's Law were applied to process the content of discharge summaries, and fuzzy formal concept analysis was used to analyze and represent the relationships between the medical terms identified by MeSH. In addition, a certainty factor used as reference during the coding process was calculated to account for uncertainty and strengthen the credibility of the outcome. Two sets of 360 and 2579 textual discharge summaries of patients suffering from cerebrovascular disease was processed to build up ICD-AS and to evaluate the prediction performance. A number of experiments were conducted to investigate the impact of system parameters on accuracy and compare the proposed model to traditional classification techniques including linear-kernel support vector machines. The comparison results showed that the proposed system achieves the better overall performance in terms of several measures. In addition, some useful implication rules were obtained, which improve comprehension of the field of cerebrovascular disease and give insights to the relationships between relevant medical terms. Our system contributes valuable guidance to disease classification specialists in the process of coding discharge summaries, which consequently brings benefits in

  16. 77 FR 54663 - Administrative Simplification: Adoption of a Standard for a Unique Health Plan Identifier...

    Science.gov (United States)

    2012-09-05

    ...- 10-CM) for diagnosis coding, including the Official ICD-10-CM Guidelines for Coding and Reporting... International Classification of Diseases, 9th Revision, Clinical Modification, Volumes 1 and 2 (diagnoses), and... available for the enumeration of SHPs based on a CHP's organizational structure and business needs. The CHP...

  17. [Differential diagnostic considerations using ICD-10 in chronic back pain with special regard to persistent somatoform pain disorder with somatic and psychological factors (ICD-10 F45.41)].

    Science.gov (United States)

    Wolff, D

    2016-06-01

    It is often difficult to pass an expert opinion in cases of chronic back pain. This article analyses the differential diagnostic considerations related to coding various causes in line with ICD-10. It emphasises the I importance of making a careful distinction between orthopoedic and psychiatric conditions and disorders. Simultaneous coding of orthopoedic and psychiatric illnesses and disorders based on a distinct cluster of symptoms necessitates an interdisciplinary approach that consistently applies the ICD-10 definitions of mental an behavioural disorders in order to clearly identify the main reason for a functional impairment in the insurance and sociomedical context. Persistant somatoform pain disorder with somatic and psychological factors (ICD-10 F45.41) should be regarded as related to the underlying disease and be used primarily as an additional and descriptive diagnosis.

  18. Surveillance of paediatric traumatic brain injuries using the NEISS: choosing an appropriate case definition.

    Science.gov (United States)

    Thompson, Meghan C; Wheeler, Krista K; Shi, Junxin; Smith, Gary A; Groner, Jonathan I; Haley, Kathryn J; Xiang, Huiyun

    2014-01-01

    To evaluate the definition of traumatic brain injury (TBI) in the National Electronic Injury Surveillance System (NEISS) and compare TBI case ascertainment using NEISS vs. ICD-9-CM diagnosis coding. Two data samples from a NEISS participating emergency department (ED) in 2008 were compared: (1) NEISS records meeting the recommended NEISS TBI definition and (2) Hospital ED records meeting the ICD-9-CM CDC recommended TBI definition. The sensitivity and positive predictive value were calculated for the NEISS definition using the ICD-9-CM definition as the gold standard. Further analyses were performed to describe cases characterized as TBIs in both datasets and to determine why some cases were not classified as TBIs in both datasets. There were 1834 TBI cases captured by the NEISS and 1836 TBI cases captured by the ICD-9-CM coded ED record, but only 1542 were eligible for inclusion in NEISS. There were 1403 cases classified as TBIs by both the NEISS and ICD-9-CM diagnosis codes. The NEISS TBI definition had a sensitivity of 91.0% (95% CI = 89.6-92.4%) and positive predictive value of 76.5% (95% CI = 74.6-78.4%). Using the NEISS TBI definition presented in this paper would standardize and improve the accuracy of TBI research using the NEISS.

  19. Using clinician text notes in electronic medical record data to validate transgender-related diagnosis codes.

    Science.gov (United States)

    Blosnich, John R; Cashy, John; Gordon, Adam J; Shipherd, Jillian C; Kauth, Michael R; Brown, George R; Fine, Michael J

    2018-04-04

    Transgender individuals are vulnerable to negative health risks and outcomes, but research remains limited because data sources, such as electronic medical records (EMRs), lack standardized collection of gender identity information. Most EMR do not include the gold standard of self-identified gender identity, but International Classification of Diseases (ICDs) includes diagnostic codes indicating transgender-related clinical services. However, it is unclear if these codes can indicate transgender status. The objective of this study was to determine the extent to which patients' clinician notes in EMR contained transgender-related terms that could corroborate ICD-coded transgender identity. Data are from the US Department of Veterans Affairs Corporate Data Warehouse. Transgender patients were defined by the presence of ICD9 and ICD10 codes associated with transgender-related clinical services, and a 3:1 comparison group of nontransgender patients was drawn. Patients' clinician text notes were extracted and searched for transgender-related words and phrases. Among 7560 patients defined as transgender based on ICD codes, the search algorithm identified 6753 (89.3%) with transgender-related terms. Among 22 072 patients defined as nontransgender without ICD codes, 246 (1.1%) had transgender-related terms; after review, 11 patients were identified as transgender, suggesting a 0.05% false negative rate. Using ICD-defined transgender status can facilitate health services research when self-identified gender identity data are not available in EMR.

  20. Validity of the coding for herpes simplex encephalitis in the Danish National Patient Registry

    DEFF Research Database (Denmark)

    Jørgensen, Laura Krogh; Dalgaard, Lars Skov; Østergaard, Lars Jørgen

    2016-01-01

    BACKGROUND: Large health care databases are a valuable source of infectious disease epidemiology if diagnoses are valid. The aim of this study was to investigate the accuracy of the recorded diagnosis coding of herpes simplex encephalitis (HSE) in the Danish National Patient Registry (DNPR...... (7.3%) as probable cases providing an overall PPV of 58.0% (95% confidence interval [CI]: 53.0-62.9). For "Encephalitis due to herpes simplex virus" (ICD-10 code B00.4), the PPV was 56.6% (95% CI: 51.1-62.0). Similarly, the PPV for "Meningoencephalitis due to herpes simplex virus" (ICD-10 code B00.4A......) was 56.8% (95% CI: 39.5-72.9). "Herpes viral encephalitis" (ICD-10 code G05.1E) had a PPV of 75.9% (95% CI: 56.5-89.7), thereby representing the highest PPV. The estimated sensitivity was 95.5%. CONCLUSION: The PPVs of the ICD-10 diagnosis coding for adult HSE in the DNPR were relatively low. Hence...

  1. Change in MS-DRG assignment and hospital reimbursement as a result of Centers for Medicare & Medicaid changes in payment for hospital-acquired conditions: is it coding or quality?

    Science.gov (United States)

    McNutt, Robert; Johnson, Tricia J; Odwazny, Richard; Remmich, Zachary; Skarupski, Kimberly; Meurer, Steven; Hohmann, Samuel; Harting, Brian

    2010-01-01

    In October 2008, the Centers for Medicare & Medicaid Services reduced payments to hospitals for a group of hospital-acquired conditions (HACs) not documented as present on admission (POA). It is unknown what proportion of Medicare severity diagnosis related group (MS-DRG) assignments will change when the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9-CM) diagnosis code for the HAC is not taken into account even before considering the POA status. The primary objectives were to estimate the proportion of cases that change MS-DRG assignment when HACs are removed from the calculation, the subsequent changes in reimbursement to hospitals, and the attenuation in changes in MS-DRG assignment after factoring in those that may be POA. Last, we explored the effect of the numbers of ICD-9-CM diagnosis codes on MS-DRG assignment. We obtained 2 years of discharge data from academic medical centers that were members of the University Health System Consortium and identified all cases with 1 of 7 HACs coded through ICD-9-CM diagnosis codes. We calculated the MS-DRG for each case with and without the HAC and, hence, the proportion where MS-DRG assignment changed. Next, we used a bootstrap method to calculate the range in the proportion of cases changing assignment to account for POA status. Changes in reimbursement were estimated by using the 2008 MS-DRG weights payment formula. Of 184,932 cases with at least 1 HAC, 27.6% (n = 52,272) would experience a change in MS-DRG assignment without the HAC factored into the assignment. After taking into account those conditions that were potentially POA, 7.5% (n = 14,176) of the original cases would change MS-DRG assignment, with an average loss in reimbursement per case ranging from $1548 with a catheter-associated urinary tract infection to $7310 for a surgical site infection. These reductions would translate into a total reimbursement loss of $50 261,692 (range: $38 330,747-$62 344,360) for the 86

  2. Code-specific learning rules improve action selection by populations of spiking neurons.

    Science.gov (United States)

    Friedrich, Johannes; Urbanczik, Robert; Senn, Walter

    2014-08-01

    Population coding is widely regarded as a key mechanism for achieving reliable behavioral decisions. We previously introduced reinforcement learning for population-based decision making by spiking neurons. Here we generalize population reinforcement learning to spike-based plasticity rules that take account of the postsynaptic neural code. We consider spike/no-spike, spike count and spike latency codes. The multi-valued and continuous-valued features in the postsynaptic code allow for a generalization of binary decision making to multi-valued decision making and continuous-valued action selection. We show that code-specific learning rules speed up learning both for the discrete classification and the continuous regression tasks. The suggested learning rules also speed up with increasing population size as opposed to standard reinforcement learning rules. Continuous action selection is further shown to explain realistic learning speeds in the Morris water maze. Finally, we introduce the concept of action perturbation as opposed to the classical weight- or node-perturbation as an exploration mechanism underlying reinforcement learning. Exploration in the action space greatly increases the speed of learning as compared to exploration in the neuron or weight space.

  3. Medicare and Medicaid Programs; CY 2016 Home Health Prospective Payment System Rate Update; Home Health Value-Based Purchasing Model; and Home Health Quality Reporting Requirements. Final rule.

    Science.gov (United States)

    2015-11-05

    This final rule will update Home Health Prospective Payment System (HH PPS) rates, including the national, standardized 60-day episode payment rates, the national per-visit rates, and the non-routine medical supply (NRS) conversion factor under the Medicare prospective payment system for home health agencies (HHAs), effective for episodes ending on or after January 1, 2016. As required by the Affordable Care Act, this rule implements the 3rd year of the 4-year phase-in of the rebasing adjustments to the HH PPS payment rates. This rule updates the HH PPS case-mix weights using the most current, complete data available at the time of rulemaking and provides a clarification regarding the use of the "initial encounter'' seventh character applicable to certain ICD-10-CM code categories. This final rule will also finalize reductions to the national, standardized 60-day episode payment rate in CY 2016, CY 2017, and CY 2018 of 0.97 percent in each year to account for estimated case-mix growth unrelated to increases in patient acuity (nominal case-mix growth) between CY 2012 and CY 2014. In addition, this rule implements a HH value-based purchasing (HHVBP) model, beginning January 1, 2016, in which all Medicare-certified HHAs in selected states will be required to participate. Finally, this rule finalizes minor changes to the home health quality reporting program and minor technical regulations text changes.

  4. Colectomy for constipation: time trends and impact based on the US Nationwide Inpatient Sample, 1998-2011.

    Science.gov (United States)

    Dudekula, A; Huftless, S; Bielefeldt, K

    2015-12-01

    Current guidelines include subtotal colectomy as treatment for refractory slow transit constipation. To use the US Nationwide Inpatient Sample (NIS) (1998-2011) and longitudinal data from the State Inpatient Database (2005-2011), comparable to NIS, to examine colectomy rates, in-hospital morbidity and emergency department (ED) visits or readmissions among patients treated for constipation. Colectomies for any reason were identified based on the primary procedural code (ICD-9-CM 45.8x). Index hospitalisations were defined by the primary diagnosis of constipation (ICD-9-CM 564.x) associated with the primary procedural code for colectomy (ICD-9-CM45.8x) after exclusion of other diseases associated with colectomy. Demographic variables, comorbidities, complications and adverse events during the hospitalisation were captured, and ED visits and admissions were recorded for periods before and after colectomy. Nationally, colectomies for constipation rose from 104 procedures in 1998 (1.2% of annual colectomies) to 311 in 2011 (2.4% of annual colectomies). While there were no perioperative deaths, perioperative complications occurred in 42.7% of patients during the index hospitalisation. Longitudinal data were analysed for 181 patients, with similar perioperative complications and a readmission rate of 28.9% within the first 30 days after the index hospitalisation. Resource utilisation was tracked for a median time of 630 (0-2386) before and 463 (0-2204) days after colectomy with unchanged ED visits (median: 2 vs. 2, P = 0.21), but increased hospitalisations (median: 1 vs. 2, P = 0.003). Colectomy rates for constipation are rising, are associated with significant morbidity and do not decrease resource utilisation, raising questions about the true benefit of surgery for slow transit constipation. © 2015 John Wiley & Sons Ltd.

  5. Coding for effective denial management.

    Science.gov (United States)

    Miller, Jackie; Lineberry, Joe

    2004-01-01

    Nearly everyone will agree that accurate and consistent coding of diagnoses and procedures is the cornerstone for operating a compliant practice. The CPT or HCPCS procedure code tells the payor what service was performed and also (in most cases) determines the amount of payment. The ICD-9-CM diagnosis code, on the other hand, tells the payor why the service was performed. If the diagnosis code does not meet the payor's criteria for medical necessity, all payment for the service will be denied. Implementation of an effective denial management program can help "stop the bleeding." Denial management is a comprehensive process that works in two ways. First, it evaluates the cause of denials and takes steps to prevent them. Second, denial management creates specific procedures for refiling or appealing claims that are initially denied. Accurate, consistent and compliant coding is key to both of these functions. The process of proactively managing claim denials also reveals a practice's administrative strengths and weaknesses, enabling radiology business managers to streamline processes, eliminate duplicated efforts and shift a larger proportion of the staff's focus from paperwork to servicing patients--all of which are sure to enhance operations and improve practice management and office morale. Accurate coding requires a program of ongoing training and education in both CPT and ICD-9-CM coding. Radiology business managers must make education a top priority for their coding staff. Front office staff, technologists and radiologists should also be familiar with the types of information needed for accurate coding. A good staff training program will also cover the proper use of Advance Beneficiary Notices (ABNs). Registration and coding staff should understand how to determine whether the patient's clinical history meets criteria for Medicare coverage, and how to administer an ABN if the exam is likely to be denied. Staff should also understand the restrictions on use of

  6. Report on FY15 alloy 617 code rules development

    Energy Technology Data Exchange (ETDEWEB)

    Sham, Sam [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jetter, Robert I [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hollinger, Greg [Becht Engineering Co., Inc., Liberty Corner, NJ (United States); Pease, Derrick [Becht Engineering Co., Inc., Liberty Corner, NJ (United States); Carter, Peter [Stress Engineering Services, Inc., Houston, TX (United States); Pu, Chao [Univ. of Tennessee, Knoxville, TN (United States); Wang, Yanli [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    Due to its strength at very high temperatures, up to 950°C (1742°F), Alloy 617 is the reference construction material for structural components that operate at or near the outlet temperature of the very high temperature gas-cooled reactors. However, the current rules in the ASME Section III, Division 5 Subsection HB, Subpart B for the evaluation of strain limits and creep-fatigue damage using simplified methods based on elastic analysis have been deemed inappropriate for Alloy 617 at temperatures above 650°C (1200°F) (Corum and Brass, Proceedings of ASME 1991 Pressure Vessels and Piping Conference, PVP-Vol. 215, p.147, ASME, NY, 1991). The rationale for this exclusion is that at higher temperatures it is not feasible to decouple plasticity and creep, which is the basis for the current simplified rules. This temperature, 650°C (1200°F), is well below the temperature range of interest for this material for the high temperature gas-cooled reactors and the very high temperature gas-cooled reactors. The only current alternative is, thus, a full inelastic analysis requiring sophisticated material models that have not yet been formulated and verified. To address these issues, proposed code rules have been developed which are based on the use of elastic-perfectly plastic (EPP) analysis methods applicable to very high temperatures. The proposed rules for strain limits and creep-fatigue evaluation were initially documented in the technical literature (Carter, Jetter and Sham, Proceedings of ASME 2012 Pressure Vessels and Piping Conference, papers PVP 2012 28082 and PVP 2012 28083, ASME, NY, 2012), and have been recently revised to incorporate comments and simplify their application. Background documents have been developed for these two code cases to support the ASME Code committee approval process. These background documents for the EPP strain limits and creep-fatigue code cases are documented in this report.

  7. Medicare Program; Inpatient Rehabilitation Facility Prospective Payment System for Federal Fiscal Year 2018. Final rule.

    Science.gov (United States)

    2017-08-03

    This final rule updates the prospective payment rates for inpatient rehabilitation facilities (IRFs) for federal fiscal year (FY) 2018 as required by the statute. As required by section 1886(j)(5) of the Social Security Act (the Act), this rule includes the classification and weighting factors for the IRF prospective payment system's (IRF PPS) case-mix groups and a description of the methodologies and data used in computing the prospective payment rates for FY 2018. This final rule also revises the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) diagnosis codes that are used to determine presumptive compliance under the "60 percent rule," removes the 25 percent payment penalty for inpatient rehabilitation facility patient assessment instrument (IRF-PAI) late transmissions, removes the voluntary swallowing status item (Item 27) from the IRF-PAI, summarizes comments regarding the criteria used to classify facilities for payment under the IRF PPS, provides for a subregulatory process for certain annual updates to the presumptive methodology diagnosis code lists, adopts the use of height/weight items on the IRF-PAI to determine patient body mass index (BMI) greater than 50 for cases of single-joint replacement under the presumptive methodology, and revises and updates measures and reporting requirements under the IRF quality reporting program (QRP).

  8. Challenges in using medicaid claims to ascertain child maltreatment.

    Science.gov (United States)

    Raghavan, Ramesh; Brown, Derek S; Allaire, Benjamin T; Garfield, Lauren D; Ross, Raven E; Hedeker, Donald

    2015-05-01

    Medicaid data contain International Classification of Diseases, Clinical Modification (ICD-9-CM) codes indicating maltreatment, yet there is a little information on how valid these codes are for the purposes of identifying maltreatment from health, as opposed to child welfare, data. This study assessed the validity of Medicaid codes in identifying maltreatment. Participants (n = 2,136) in the first National Survey of Child and Adolescent Well-Being were linked to their Medicaid claims obtained from 36 states. Caseworker determinations of maltreatment were compared with eight sets of ICD-9-CM codes. Of the 1,921 children identified by caseworkers as being maltreated, 15.2% had any relevant ICD-9-CM code in any of their Medicaid files across 4 years of observation. Maltreated boys and those of African American race had lower odds of displaying a maltreatment code. Using only Medicaid claims to identify maltreated children creates validity problems. Medicaid data linkage with other types of administrative data is required to better identify maltreated children. © The Author(s) 2014.

  9. Impact of documentation errors on accuracy of cause of death coding in an educational hospital in Southern Iran.

    Science.gov (United States)

    Haghighi, Mohammad Hosein Hayavi; Dehghani, Mohammad; Teshnizi, Saeid Hoseini; Mahmoodi, Hamid

    2014-01-01

    Accurate cause of death coding leads to organised and usable death information but there are some factors that influence documentation on death certificates and therefore affect the coding. We reviewed the role of documentation errors on the accuracy of death coding at Shahid Mohammadi Hospital (SMH), Bandar Abbas, Iran. We studied the death certificates of all deceased patients in SMH from October 2010 to March 2011. Researchers determined and coded the underlying cause of death on the death certificates according to the guidelines issued by the World Health Organization in Volume 2 of the International Statistical Classification of Diseases and Health Related Problems-10th revision (ICD-10). Necessary ICD coding rules (such as the General Principle, Rules 1-3, the modification rules and other instructions about death coding) were applied to select the underlying cause of death on each certificate. Demographic details and documentation errors were then extracted. Data were analysed with descriptive statistics and chi square tests. The accuracy rate of causes of death coding was 51.7%, demonstrating a statistically significant relationship (p=.001) with major errors but not such a relationship with minor errors. Factors that result in poor quality of Cause of Death coding in SMH are lack of coder training, documentation errors and the undesirable structure of death certificates.

  10. Distribución del presupuesto sanitario público de Cataluña del año 2005 entre las 17 categorías CIE-9-MC Distribution of the public healthcare budget of Catalonia (Spain for 2005 among the 17 ICD-9-CM categories

    Directory of Open Access Journals (Sweden)

    Ramón Gisbert

    2007-04-01

    modification categories. Material and method: The methodology comprised 2 phases: an initial phase in which the global budget was distributed by type of healthcare (hospital, outpatient or pharmacological care, and a second phase in which the expenditure was distributed by the type of care among the ICD-9-CM categories. In the first phase, this distribution was based on information enabling the various budget items to be assigned to the different types of care. Various elements were used for the distribution by categories, depending on each type of care: hospital stay, outpatient visit or consumption by therapeutic subgroup. Results: Distribution of the budget was as follows: 46.6% for specialized care, 27.5% for pharmacological care, and 20.0% for primary care; 5.9% was not distributed. Of the 17 categories, that accounting for the largest percentage (17.3% was «diseases of the circulatory system» (VII, followed by category VIII, «diseases of the respiratory system» which totaled 10.9%. The budget was concentrated in 5 categories, the 2 mentioned above plus category V «mental disorders» (9.4%, category II «tumors» (9.1% and category IX «disorders of the digestive system» (7.7%, which accounted for 54.4% of the total budget. The internal composition of each category showed major variations. Conclusion: The distribution of the budget offers a point of reference for health planning and management.

  11. Coding training for medical students: How good is diagnoses coding with ICD-10 by novices?

    Directory of Open Access Journals (Sweden)

    Stausberg, Jürgen

    2005-04-01

    Full Text Available Teaching of knowledge and competence in documentation and coding is an essential part of medical education. Therefore, coding training had been placed within the course of epidemiology, medical biometry, and medical informatics. From this, we can draw conclusions about the quality of coding by novices. One hundred and eighteen students coded diagnoses from 15 nephrological cases in homework. In addition to interrater reliability, validity was calculated by comparison with a reference coding. On the level of terminal codes, 59.3% of the students' results were correct. The completeness was calculated as 58.0%. The results on the chapter level increased up to 91.5% and 87.7% respectively. For the calculation of reliability a new, simple measure was developed that leads to values of 0.46 on the level of terminal codes and 0.87 on the chapter level for interrater reliability. The figures of concordance with the reference coding are quite similar. In contrary, routine data show considerably lower results with 0.34 and 0.63 respectively. Interrater reliability and validity of coding by novices is as good as coding by experts. The missing advantage of experts could be explained by the workload of documentation and a negative attitude to coding on the one hand. On the other hand, coding in a DRG-system is handicapped by a large number of detailed coding rules, which do not end in uniform results but rather lead to wrong and random codes. Anyway, students left the course well prepared for coding.

  12. Immunohistochemical analysis based Ep-ICD subcellular localization index (ESLI) is a novel marker for metastatic papillary thyroid microcarcinoma

    International Nuclear Information System (INIS)

    Kunavisarut, Tada; Kak, Ipshita; MacMillan, Christina; Ralhan, Ranju; Walfish, Paul G

    2012-01-01

    Thyroid cancer is among the fastest growing malignancies; almost fifty-percent of these rapidly increasing incidence tumors are less than or equal to 1cm in size, termed papillary thyroid microcarcinoma (PTMC). The management of PTMC remains a controversy due to differing natural history of these patients. Epithelial cell adhesion molecule (EpCAM) is comprised of an extracellular domain (EpEx), a single transmembrane domain and an intracellular domain (Ep-ICD). Our group reported nuclear Ep-ICD correlated with poor prognosis in thyroid cancer (Ralhan et al., BMC Cancer 2010,10:331). Here in, we hypothesized nuclear and cytoplasmic accumulation of Ep-ICD and loss of membranous EpEx may aid in distinguishing metastatic from non-metastatic PTMC, which is an important current clinical challenge. To test our hypothesis, Ep-ICD and EpEx expression levels were analyzed in PTMC and the staining was correlated with metastatic potential of these carcinomas. Thirty-six PTMC patients (tumor size 0.5 - 1cm; metastatic 8 cases and non-metastatic 28 cases) who underwent total thyroidectomy were selected. The metastatic group consisted of patients who developed lymph node or distant metastasis at diagnosis or during follow up. The patients’ tissues were stained for Ep-ICD and EpEx using domain specific antibodies by immunohistochemistry and evaluated. PTMC patients with metastasis had higher scores for nuclear and cytoplasmic Ep-ICD immunostaining than the patients without metastasis (1.96 ± 0.86 vs. 1.22 ± 0.45; p = 0.007 and 5.37 ± 0.33 vs. 4.72 ± 1.07; p = 0.016, respectively). Concomitantly, the former had lower scores for membrane EpEx than the non-metastatic group (4.64 ± 1.08 vs. 5.64 ± 1.51; p = 0.026). An index of aggressiveness, Ep-ICD subcellular localization index (ESLI), was defined as sum of the IHC scores for accumulation of nuclear and cytoplasmic Ep-ICD and loss of membranous EpEx; ESLI = [Ep − ICD nuc + Ep − ICD cyt + loss of membranous EpEx]. Notably

  13. Asphyxia in the Newborn: Evaluating the Accuracy of ICD Coding, Clinical Diagnosis and Reimbursement: Observational Study at a Swiss Tertiary Care Center on Routinely Collected Health Data from 2012-2015.

    Directory of Open Access Journals (Sweden)

    Olga Endrich

    Full Text Available The ICD-10 categories of the diagnosis "perinatal asphyxia" are defined by clinical signs and a 1-minute Apgar score value. However, the modern conception is more complex and considers metabolic values related to the clinical state. A lack of consistency between the former clinical and the latter encoded diagnosis poses questions over the validity of the data. Our aim was to establish a refined classification which is able to distinctly separate cases according to clinical criteria and financial resource consumption. The hypothesis of the study is that outdated ICD-10 definitions result in differences between the encoded diagnosis asphyxia and the medical diagnosis referring to the clinical context.Routinely collected health data (encoding and financial data of the University Hospital of Bern were used. The study population was chosen by selected ICD codes, the encoded and the clinical diagnosis were analyzed and each case was reevaluated. The new method categorizes the diagnoses of perinatal asphyxia into the following groups: mild, moderate and severe asphyxia, metabolic acidosis and normal clinical findings. The differences of total costs per case were determined by using one-way analysis of variance.The study population included 622 cases (P20 "intrauterine hypoxia" 399, P21 "birth asphyxia" 233. By applying the new method, the diagnosis asphyxia could be ruled out with a high probability in 47% of cases and the variance of case related costs (one-way ANOVA: F (5, 616 = 55.84, p < 0.001, multiple R-squared = 0.312, p < 0.001 could be best explained. The classification of the severity of asphyxia could clearly be linked to the complexity of cases.The refined coding method provides clearly defined diagnoses groups and has the strongest effect on the distribution of costs. It improves the diagnosis accuracy of perinatal asphyxia concerning clinical practice, research and reimbursement.

  14. Importance of external cause coding for injury surveillance: lessons from assessment of overexertion injuries among U.S. Army soldiers in 2014.

    Science.gov (United States)

    Canham-Chervak, Michelle; Steelman, Ryan A; Schuh, Anna; Jones, Bruce H

    2016-11-01

    Injuries are a barrier to military medical readiness, and overexertion has historically been a leading mechanism of injury among active duty U.S. Army soldiers. Details are needed to inform prevention planning. The Defense Medical Surveillance System (DMSS) was queried for unique medical encounters among active duty Army soldiers consistent with the military injury definition and assigned an overexertion external cause code (ICD-9: E927.0-E927.9) in 2014 (n=21,891). Most (99.7%) were outpatient visits and 60% were attributed specifically to sudden strenuous movement. Among the 41% (n=9,061) of visits with an activity code (ICD-9: E001-E030), running was the most common activity (n=2,891, 32%); among the 19% (n=4,190) with a place of occurrence code (ICD-9: E849.0-E849.9), the leading location was recreation/sports facilities (n=1,332, 32%). External cause codes provide essential details, but the data represented less than 4% of all injury-related medical encounters among U.S. Army soldiers in 2014. Efforts to improve external cause coding are needed, and could be aligned with training on and enforcement of ICD-10 coding guidelines throughout the Military Health System.

  15. Proposal to modify Rule 6, Rule 10a, and Rule 12c of the International Code of Nomenclature of Prokaryotes.

    Science.gov (United States)

    Oren, Aharon; Garrity, George M; Schink, Bernhard

    2014-04-01

    According to the current versions of Rule 10a and Rule 12c of the International Code of Nomenclature of Prokaryotes, names of a genus or subgenus and specific epithets may be taken from any source and may even be composed in an arbitrary manner. Based on these rules, names may be composed of any word or any combination of elements derived from any language with a Latin ending. We propose modifying these rules by adding the text, currently part of Recommendation 6, according to which words from languages other than Latin or Greek should be avoided as long as equivalents exist in Latin or Greek or can be constructed by combining word elements from these two languages. We also propose modification of Rule 6 by adopting some of the current paragraphs of Recommendation 6 to become part of the Rule.

  16. Just-in-time coding of the problem list in a clinical environment.

    Science.gov (United States)

    Warren, J. J.; Collins, J.; Sorrentino, C.; Campbell, J. R.

    1998-01-01

    Clinically useful problem lists are essential to the CPR. Providing a terminology that is standardized and understood by all clinicians is a major challenge. UNMC has developed a lexicon to support their problem list. Using a just-in-time coding strategy, the lexicon is maintained and extended prospectively in a dynamic clinical environment. The terms in the lexicon are mapped to ICD-9-CM, NANDA, and SNOMED International classification schemes. Currently, the lexicon contains 12,000 terms. This process of development and maintenance of the lexicon is described. PMID:9929226

  17. Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.

    Science.gov (United States)

    Kutyifa, Valentina; Daubert, James P; Schuger, Claudio; Goldenberg, Ilan; Klein, Helmut; Aktas, Mehmet K; McNitt, Scott; Stockburger, Martin; Merkely, Bela; Zareba, Wojciech; Moss, Arthur J

    2016-01-01

    The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25-0.57; Pprogramming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; Pprogramming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. http://clinicaltrials.gov; Unique identifier: NCT00947310. © 2016 American Heart Association, Inc.

  18. Use of diagnosis codes for detection of clinically significant opioid poisoning in the emergency department: A retrospective analysis of a surveillance case definition.

    Science.gov (United States)

    Reardon, Joseph M; Harmon, Katherine J; Schult, Genevieve C; Staton, Catherine A; Waller, Anna E

    2016-02-08

    Although fatal opioid poisonings tripled from 1999 to 2008, data describing nonfatal poisonings are rare. Public health authorities are in need of tools to track opioid poisonings in near real time. We determined the utility of ICD-9-CM diagnosis codes for identifying clinically significant opioid poisonings in a state-wide emergency department (ED) surveillance system. We sampled visits from four hospitals from July 2009 to June 2012 with diagnosis codes of 965.00, 965.01, 965.02 and 965.09 (poisoning by opiates and related narcotics) and/or an external cause of injury code of E850.0-E850.2 (accidental poisoning by opiates and related narcotics), and developed a novel case definition to determine in which cases opioid poisoning prompted the ED visit. We calculated the percentage of visits coded for opioid poisoning that were clinically significant and compared it to the percentage of visits coded for poisoning by non-opioid agents in which there was actually poisoning by an opioid agent. We created a multivariate regression model to determine if other collected triage data can improve the positive predictive value of diagnosis codes alone for detecting clinically significant opioid poisoning. 70.1 % of visits (Standard Error 2.4 %) coded for opioid poisoning were primarily prompted by opioid poisoning. The remainder of visits represented opioid exposure in the setting of other primary diseases. Among non-opioid poisoning codes reviewed, up to 36 % were reclassified as an opioid poisoning. In multivariate analysis, only naloxone use improved the positive predictive value of ICD-9-CM codes for identifying clinically significant opioid poisoning, but was associated with a high false negative rate. This surveillance mechanism identifies many clinically significant opioid overdoses with a high positive predictive value. With further validation, it may help target control measures such as prescriber education and pharmacy monitoring.

  19. Upper limits on the 21 cm power spectrum at z = 5.9 from quasar absorption line spectroscopy

    Science.gov (United States)

    Pober, Jonathan C.; Greig, Bradley; Mesinger, Andrei

    2016-11-01

    We present upper limits on the 21 cm power spectrum at z = 5.9 calculated from the model-independent limit on the neutral fraction of the intergalactic medium of x_{H I} chain Monte Carlo Epoch of Reionization analysis code, we explore the probability distribution of 21 cm power spectra consistent with this constraint on the neutral fraction. We present 99 per cent confidence upper limits of Δ2(k) limit dependent on the sampled k mode. This limit can be used as a null test for 21 cm experiments: a detection of power at z = 5.9 in excess of this value is highly suggestive of residual foreground contamination or other systematic errors affecting the analysis.

  20. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  1. An Embedded Rule-Based Diagnostic Expert System in Ada

    Science.gov (United States)

    Jones, Robert E.; Liberman, Eugene M.

    1992-01-01

    Ada is becoming an increasingly popular programming language for large Government-funded software projects. Ada with it portability, transportability, and maintainability lends itself well to today's complex programming environment. In addition, expert systems have also assumed a growing role in providing human-like reasoning capability expertise for computer systems. The integration is discussed of expert system technology with Ada programming language, especially a rule-based expert system using an ART-Ada (Automated Reasoning Tool for Ada) system shell. NASA Lewis was chosen as a beta test site for ART-Ada. The test was conducted by implementing the existing Autonomous Power EXpert System (APEX), a Lisp-based power expert system, in ART-Ada. Three components, the rule-based expert systems, a graphics user interface, and communications software make up SMART-Ada (Systems fault Management with ART-Ada). The rules were written in the ART-Ada development environment and converted to Ada source code. The graphics interface was developed with the Transportable Application Environment (TAE) Plus, which generates Ada source code to control graphics images. SMART-Ada communicates with a remote host to obtain either simulated or real data. The Ada source code generated with ART-Ada, TAE Plus, and communications code was incorporated into an Ada expert system that reads the data from a power distribution test bed, applies the rule to determine a fault, if one exists, and graphically displays it on the screen. The main objective, to conduct a beta test on the ART-Ada rule-based expert system shell, was achieved. The system is operational. New Ada tools will assist in future successful projects. ART-Ada is one such tool and is a viable alternative to the straight Ada code when an application requires a rule-based or knowledge-based approach.

  2. A New Coding System for Metabolic Disorders Demonstrates Gaps in the International Disease Classifications ICD-10 and SNOMED-CT, Which Can Be Barriers to Genotype-Phenotype Data Sharing

    NARCIS (Netherlands)

    Sollie, Annet; Sijmons, Rolf H.; Lindhout, Dick; van der Ploeg, Ans T.; Gozalbo, M. Estela Rubio; Smit, G. Peter A.; Verheijen, Frans; Waterham, Hans R.; van Weely, Sonja; Wijburg, Frits A.; Wijburg, Rudolph; Visser, Gepke

    Data sharing is essential for a better understanding of genetic disorders. Good phenotype coding plays a key role in this process. Unfortunately, the two most widely used coding systems in medicine, ICD-10 and SNOMED-CT, lack information necessary for the detailed classification and annotation of

  3. The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial.

    Science.gov (United States)

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina; McNitt, Scott; Thomsen, Poul Erik Bloch; Klein, Helmut; Stockburger, Martin; Wichterle, Dan; Merkely, Bela; DE LA Concha, Joaquin Fernandez; Swissa, Moshe; Zareba, Wojciech; Moss, Arthur J; Kautzner, Josef; Ruwald, Martin H

    2015-04-01

    The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy. © 2014 Wiley Periodicals, Inc.

  4. Methodological approaches based on business rules

    Directory of Open Access Journals (Sweden)

    Anca Ioana ANDREESCU

    2008-01-01

    Full Text Available Business rules and business processes are essential artifacts in defining the requirements of a software system. Business processes capture business behavior, while rules connect processes and thus control processes and business behavior. Traditionally, rules are scattered inside application code. This approach makes it very difficult to change rules and shorten the life cycle of the software system. Because rules change more quickly than the application itself, it is desirable to externalize the rules and move them outside the application. This paper analyzes and evaluates three well-known business rules approaches. It also outlines some critical factors that have to be taken into account in the decision to introduce business rules facilities in a software system. Based on the concept of explicit manipulation of business rules in a software system, the need for a general approach based on business rules is discussed.

  5. Creep-fatigue rules in the RCC-MR code

    International Nuclear Information System (INIS)

    Drubay, B.

    1988-01-01

    In 1978, CEA, Electricite de France (EDF) and NOVATOME decided to draw up a complete set of design and construction rules for LMFBR components. This RCC-MR code issued in June 1985 and completed in November 1987 was chosen as a sound basis for the next European Fast Reactor (EFR). The purpose of this paper is to describe the present RCC-MR creep-fatigue design rules to be applied with elastic analysis including the modifications adopted in the first addenda. This method is based on a separate evaluation of a fatigue usage fraction V and creep rupture usage fraction W with the common linear summation rule. The fatigue usage fraction is obtained from continuous fatigue curves (without hold times) and from total strain ranges (elastic + plastic + creep). The creep rupture usage fraction W is obtained from stress to rupture curves and a stress σk evaluating the stress generated during the cycle. (author)

  6. [Restrictions for ICD patients in daily life].

    Science.gov (United States)

    Köbe, Julia; Gradaus, Rainer; Zumhagen, Sven; Böcker, Dirk

    2005-11-01

    Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging

  7. Codification of LMFBR rules and comparison of codes

    International Nuclear Information System (INIS)

    Faure, O.; Debaene, J.P.

    1993-01-01

    The first part of this report presents the basic RCC-MR (regles de conception et de construction des materiels mecaniques des ilots nucleaires, reacteurs a neutrons rapides) design rules and their purpose. The second part is a qualitative comparison between RCC-MR, Code case N47 (ASME) and ETSDG Guide (MONJU Guide), made on the following topics: negligible creep test, ratcheting, creep fatigue, buckling, piping rules. An outline is given on improvements to RCC-MR rules now in progress

  8. Evidence of distinct profiles of Posttraumatic Stress Disorder (PTSD) and Complex Posttraumatic Stress Disorder (CPTSD) based on the new ICD-11 Trauma Questionnaire (ICD-TQ).

    Science.gov (United States)

    Karatzias, Thanos; Shevlin, Mark; Fyvie, Claire; Hyland, Philip; Efthymiadou, Erifili; Wilson, Danielle; Roberts, Neil; Bisson, Jonathan I; Brewin, Chris R; Cloitre, Marylene

    2017-01-01

    The WHO International Classification of Diseases, 11th version (ICD-11), has proposed two related diagnoses following exposure to traumatic events; Posttraumatic Stress Disorder (PTSD) and Complex PTSD (CPTSD). We set out to explore whether the newly developed ICD-11 Trauma Questionnaire (ICD-TQ) can distinguish between classes of individuals according to the PTSD and CPTSD symptom profiles as per ICD-11 proposals based on latent class analysis. We also hypothesized that the CPTSD class would report more frequent and a greater number of different types of childhood trauma as well as higher levels of functional impairment. Methods Participants in this study were a sample of individuals who were referred for psychological therapy to a National Health Service (NHS) trauma centre in Scotland (N=193). Participants completed the ICD-TQ as well as measures of life events and functioning. Overall, results indicate that using the newly developed ICD-TQ, two subgroups of treatment-seeking individuals could be empirically distinguished based on different patterns of symptom endorsement; a small group high in PTSD symptoms only and a larger group high in CPTSD symptoms. In addition, CPTSD was more strongly associated with more frequent and a greater accumulation of different types of childhood traumatic experiences and poorer functional impairment. Sample predominantly consisted of people who had experienced childhood psychological trauma or been multiply traumatised in childhood and adulthood. CPTSD is highly prevalent in treatment seeking populations who have been multiply traumatised in childhood and adulthood and appropriate interventions should now be developed to aid recovery from this debilitating condition. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. 78 FR 12264 - Criteria for a Catastrophically Disabled Determination for Purposes of Enrollment

    Science.gov (United States)

    2013-02-22

    ... descriptions for the same medical condition. ICD-10-PCS also introduces new terminology. For example, the term... Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) and Current Procedural Terminology... Medical Association. CPT codes and descriptions are copyrighted by the American Medical Association. All...

  10. Identifying Adverse Events Using International Classification of Diseases, Tenth Revision Y Codes in Korea: A Cross-sectional Study

    Directory of Open Access Journals (Sweden)

    Minsu Ock

    2018-01-01

    Full Text Available Objectives The use of administrative data is an affordable alternative to conducting a difficult large-scale medical-record review to estimate the scale of adverse events. We identified adverse events from 2002 to 2013 on the national level in Korea, using International Classification of Diseases, tenth revision (ICD-10 Y codes. Methods We used data from the National Health Insurance Service-National Sample Cohort (NHIS-NSC. We relied on medical treatment databases to extract information on ICD-10 Y codes from each participant in the NHIS-NSC. We classified adverse events in the ICD-10 Y codes into 6 types: those related to drugs, transfusions, and fluids; those related to vaccines and immunoglobulin; those related to surgery and procedures; those related to infections; those related to devices; and others. Results Over 12 years, a total of 20 817 adverse events were identified using ICD-10 Y codes, and the estimated total adverse event rate was 0.20%. Between 2002 and 2013, the total number of such events increased by 131.3%, from 1366 in 2002 to 3159 in 2013. The total rate increased by 103.9%, from 0.17% in 2002 to 0.35% in 2013. Events related to drugs, transfusions, and fluids were the most common (19 446, 93.4%, followed by those related to surgery and procedures (1209, 5.8% and those related to vaccines and immunoglobulin (72, 0.3%. Conclusions Based on a comparison with the results of other studies, the total adverse event rate in this study was significantly underestimated. Improving coding practices for ICD-10 Y codes is necessary to precisely monitor the scale of adverse events in Korea.

  11. Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal

    2016-01-01

    The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  12. Designing a software for systematic registration of oral and maxillofacial diseases based on the latest update of the World Health Organization ICD-10 classification system in 2010

    Directory of Open Access Journals (Sweden)

    Arash Mansorian

    2014-04-01

    Full Text Available   Background and Aims: Classification is a fundamental issue in quantitative studies of any phenomenon and has been known as a necessity for the advancement of science. Using a standard record system for diseases is critical for research purposes and also could improve the quality of medical health services. In this study, after evaluating current codding systems in oral medicine, we designed a software for systematic coding and registration of Oral and Maxillofacial diseases based on the latest update of the World Health Organization ICD-10 classification system in 2010.   Materials and Methods: Based on the latest WHO ICD-10 update in 2010 and by using software s as: vb.net, net framework, SQL Server and Microsoft Visual Studio, standard coding software for recording patient's data at the department of Oral Medicine, School of Dentistry, Tehran University of Medical Sciences was designed. Data from all patients were codded by standard ICD-10 codes and registered by the software. Also an online portal for recording patient's data which could be used nationwide was designed. By d esigning this software the process of forming and registering patient's records, and their treatment process is facilitated . An archive of patient data was also stablished .   Conclusion: As a result , this software in addition to maintaining patient data , facilitate studies and research projects greatly. It’s recommended that the Iranian Ministry of Health and Medical Education as the concessioner of this software, improves codding and registration systems of oral diseases at the dental schools by developing this software.

  13. Validation study in four health-care databases: upper gastrointestinal bleeding misclassification affects precision but not magnitude of drug-related upper gastrointestinal bleeding risk.

    Science.gov (United States)

    Valkhoff, Vera E; Coloma, Preciosa M; Masclee, Gwen M C; Gini, Rosa; Innocenti, Francesco; Lapi, Francesco; Molokhia, Mariam; Mosseveld, Mees; Nielsson, Malene Schou; Schuemie, Martijn; Thiessard, Frantz; van der Lei, Johan; Sturkenboom, Miriam C J M; Trifirò, Gianluca

    2014-08-01

    To evaluate the accuracy of disease codes and free text in identifying upper gastrointestinal bleeding (UGIB) from electronic health-care records (EHRs). We conducted a validation study in four European electronic health-care record (EHR) databases such as Integrated Primary Care Information (IPCI), Health Search/CSD Patient Database (HSD), ARS, and Aarhus, in which we identified UGIB cases using free text or disease codes: (1) International Classification of Disease (ICD)-9 (HSD, ARS); (2) ICD-10 (Aarhus); and (3) International Classification of Primary Care (ICPC) (IPCI). From each database, we randomly selected and manually reviewed 200 cases to calculate positive predictive values (PPVs). We employed different case definitions to assess the effect of outcome misclassification on estimation of risk of drug-related UGIB. PPV was 22% [95% confidence interval (CI): 16, 28] and 21% (95% CI: 16, 28) in IPCI for free text and ICPC codes, respectively. PPV was 91% (95% CI: 86, 95) for ICD-9 codes and 47% (95% CI: 35, 59) for free text in HSD. PPV for ICD-9 codes in ARS was 72% (95% CI: 65, 78) and 77% (95% CI: 69, 83) for ICD-10 codes (Aarhus). More specific definitions did not have significant impact on risk estimation of drug-related UGIB, except for wider CIs. ICD-9-CM and ICD-10 disease codes have good PPV in identifying UGIB from EHR; less granular terminology (ICPC) may require additional strategies. Use of more specific UGIB definitions affects precision, but not magnitude, of risk estimates. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Variability in clinical diagnoses during the ICD-8 and ICD-10 era

    DEFF Research Database (Denmark)

    Frederiksen, Julie E Nordgaard; Jessen, Kasper; Sæbye, Ditte

    2016-01-01

    university-affiliated departments of psychiatry in Denmark in two time periods: 1980-1985 (ICD-8) and 2001-2010 (ICD-10). RESULTS: The synchronic inter-departmental diagnostic differences did not decrease in the ICD-10 era compared with ICD-8 era. Nor did the diachronic stability within each department...

  15. Setting new global rules? : TNCs and codes of conduct

    NARCIS (Netherlands)

    Kolk, A.; van Tulder, R.

    2005-01-01

    The introduction of codes of conduct can be seen as an expression of corporate social responsibility, but also as rule-setting behaviour - attempts to help fill some of the existing international instutitional voids. To shed light on these aspects and the (potential) effectiveness of codes, this

  16. Higher risk of developing a subsequent migraine in adults with nonapnea sleep disorders: A nationwide population-based cohort study.

    Science.gov (United States)

    Harnod, Tomor; Wang, Yu-Chiao; Kao, Chia-Hung

    2015-05-01

    This nationwide population-based cohort study evaluated the effect of nonapnea sleep disorders (NSDs) on the subsequent development of a migraine. We identified 46,777 patients aged 20 years and older who were diagnosed with an NSD (ICD-9-CM: 307.4 or 780.5) and without coding for apnea-sleep disorders (ICD-9-CM: 780.51, 780.53, or 780.57) between 2000 and 2002 as the sleep disorder (SD) cohort. A comparison cohort of 93,552 people was enrolled. We calculated the adjusted hazard ratio (aHR) for developing a migraine (ICD-9-CM: 346) after adjusting for age, sex, comorbidity, and drug use. A Kaplan-Meier analysis was used to measure the cumulative incidence of a migraine between 2 curves until the end of 2011. The cumulative incidence of a migraine was significantly higher in the SD cohort. The aHR for developing a migraine in the SD cohort was 3.52 (95% CI=3.28-3.79). The risk of developing a migraine with an NSD was higher in men (aHR=4.31) than in women (aHR=3.35). The age-stratified effect of an NSD on developing a migraine was highest among patients aged 55 years and younger. Higher risks of developing a migraine were observed among the participants without any comorbidity and without any drug treatment for their insomnia. The findings of this population-based cohort study indicate a higher risk of developing a subsequent migraine in patients with an NSD, which could be considered an independent, predisposing factor for developing subsequent a migraine in adulthood. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  17. Consideration of creep in design rules of AFCEN RCC-MRx 2012 code

    International Nuclear Information System (INIS)

    Lebarbe, T.; Petesch, C.; Lejeail, Y.; Lamagnere, P.; Dubiez-Le Goff, S.

    2014-01-01

    The 2012 edition of the RCC-MRx Code has been issued in French and English versions by AFCEN (Association Francaise pour les regles de Conception et de Construction des Materiels des Chaudieres Electro-nucleaires). This Code is the result of the merger of the RCC-MX 2008 developed in the context of the research reactor Jules Horowitz Reactor project, in the RCC-MR 2007 which set up rules applicable to the design of components operating at high temperature and to the Vacuum Vessel of ITER. This new edition is the opportunity to publish also the background of the rules. This paper is one illustration of what may be such a document, on a dedicated example, the creep rules. It contains an overview of the design rules associated to the creep damage and explains the purpose and the origins of these rules. This type of exercise is going to be generalized to all the parts of the code in AFCEN technical publications, the criteria. (authors)

  18. Use of ICD-10 codes to monitor uterine rupture

    DEFF Research Database (Denmark)

    Thisted, Dorthe L A; Mortensen, Laust Hvas; Hvidman, Lone

    2014-01-01

    OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine the vali......OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine...... uterine ruptures, the sensitivity and specificity of the codes for uterine rupture were 83.8% and 99.1%, respectively. CONCLUSION: During the study period the monitoring of uterine rupture in the MBR was inadequate....

  19. The anti-tumor efficacy of nanoparticulate form of ICD-85 versus free form

    Directory of Open Access Journals (Sweden)

    Zare Mirakabadi, A.

    2015-04-01

    Full Text Available Biodegradable polymeric nanoparticles (NPs have been intensively studied as a possible way to enhance anti-tumor efficacy while reducing side effects. ICD-85, derived from the venom of two separate species of venomous animals, has been shown to exhibit anti-cancer activity. In this report polymer based sodium alginate nanoparticles of ICD-85 was used to enhance its therapeutic effects and reduce its side effects. The inhibitory effect was evaluated by MTT assay. The necrotic effect was assessed using LDH assay. The induction of apoptosis was analyzed by caspase-8 colorimetric assay kit. Cytotoxicity assay in HeLa cells demonstrated enhanced efficacy of ICD-85 loaded NPs compared to the free ICD-85. The IC50 values obtained in HeLa cells after 48 h, for free ICD-85 and ICD-85 loaded NPs were 26±2.9μg ml-1 and 18±2.5μg ml-1, respectively. While it was observed that free ICD-85 exhibits mild cytotoxicity towards normal MRC-5 cells (IC50>60μg ml-1, ICD-85 loaded NPs was found to have higher efficacy in anti-proliferative activity on HeLa cells in vitro without any significant cytotoxic effect on normal MRC-5 cells. The apoptosis-induction mechanism by both form of ICD-85 on HeLa cells was found to be through activation of caspase-8 with approximately 2 fold greater of ICD-85 loaded NPs as compared to free ICD-85. Our work reveals that although ICD-85 in free form is relatively selective to inhibit the growth of cancer cells via apoptosis as compared to normal cells, but nanoparticulate form increases its selectivity towards cancer cells.

  20. Depathologising gender diversity in childhood in the process of ICD revision and reform.

    Science.gov (United States)

    Suess Schwend, Amets; Winter, Sam; Chiam, Zhan; Smiley, Adam; Cabral Grinspan, Mauro

    2018-01-24

    From 2007 on, the World Health Organisation (WHO) has been revising its diagnostic manual, the International Statistical Classification of Diseases and Related Health Problems (ICD), with approval of ICD-11 due in 2018. The ICD revision has prompted debates on diagnostic classifications related to gender diversity and gender development processes, and specifically on the 'Gender incongruence of childhood' (GIC) code. These debates have taken place at a time an emergent trans depathologisation movement is becoming increasingly international, and regional and international human rights bodies are recognising gender identity as a source of discrimination. With reference to the history of diagnostic classification of gender diversity in childhood, this paper conducts a literature review of academic, activist and institutional documents related to the current discussion on the merits of retaining or abandoning the GIC code. Within this broader discussion, the paper reviews in more detail recent publications arguing for the abandonment of this diagnostic code drawing upon clinical, bioethical and human rights perspectives. The review indicates that gender diverse children engaged in exploring their gender identity and expression do not benefit from diagnosis. Instead they benefit from support from their families, their schools and from society more broadly.

  1. Validity of vascular trauma codes at major trauma centres.

    Science.gov (United States)

    Altoijry, Abdulmajeed; Al-Omran, Mohammed; Lindsay, Thomas F; Johnston, K Wayne; Melo, Magda; Mamdani, Muhammad

    2013-12-01

    The use of administrative databases in vascular injury research has been increasing, but the validity of the diagnosis codes used in this research is uncertain. We assessed the positive predictive value (PPV) of International Classification of Diseases, tenth revision (ICD-10), vascular injury codes in administrative claims data in Ontario. We conducted a retrospective validation study using the Canadian Institute for Health Information Discharge Abstract Database, an administrative database that records all hospital admissions in Canada. We evaluated 380 randomly selected hospital discharge abstracts from the 2 main trauma centres in Toronto, Ont., St.Michael's Hospital and Sunnybrook Health Sciences Centre, between Apr. 1, 2002, and Mar. 31, 2010. We then compared these records with the corresponding patients' hospital charts to assess the level of agreement for procedure coding. We calculated the PPV and sensitivity to estimate the validity of vascular injury diagnosis coding. The overall PPV for vascular injury coding was estimated to be 95% (95% confidence interval [CI] 92.3-96.8). The PPV among code groups for neck, thorax, abdomen, upper extremity and lower extremity injuries ranged from 90.8 (95% CI 82.2-95.5) to 97.4 (95% CI 91.0-99.3), whereas sensitivity ranged from 90% (95% CI 81.5-94.8) to 98.7% (95% CI 92.9-99.8). Administrative claims hospital discharge data based on ICD-10 diagnosis codes have a high level of validity when identifying cases of vascular injury. Observational Study Level III.

  2. General anesthesia exposure in early life reduces the risk of allergic diseases: A nationwide population-based cohort study.

    Science.gov (United States)

    Kuo, Ho-Chang; Yang, Ya-Ling; Ho, Shu-Chen; Guo, Mindy Ming-Huey; Jiang, Jyun-Hong; Huang, Ying-Hsien

    2016-07-01

    General anesthesia (GA) has been used for second line treatment strategy for status asthmaticus in pediatric patients. The association between GA in children and risk of followed-up allergic diseases is unclear. This study aims to assess the risk of allergic diseases after GA in children.We did a nationwide retrospective cohort study by analyzing data from the National Health Insurance Research Database (NHIRD) in Taiwan. The subsequent risks for allergic diseases, including asthma (ICD-9: 493.X), allergic rhinitis (AR; ICD-9 CM code 477.X), and atopic dermatitis (AD; ICD-9-CM code 691.X), were compared between exposure to GA and none before 1 year of age throughout the follow-up period using the Cox proportional hazards model.Insurance claims data for 32,742 children younger than 1 year old from all insured children in the NHIRD. Of those, 2358 subjects were exposed to GA; 414 and 1944 children exposed to mask and intubation ventilation, respectively, served as the study cohort, whereas the remaining 30,384 children made up the comparison cohort. Children in the GA group were at a lower risk of developing asthma, AR and AD, with adjusted hazard ratios of 0.67 (0.62-0.72, 95%CI), 0.72 (0.68-0.77, 95%CI), 0.60 (0.56-0.64, 95%CI), respectively.Children who were exposed to GA in early life before 1 year of age had reduced risk of subsequently developing allergic diseases such as asthma, AD, and AR, when compared with general population.

  3. Acute evaluation of transthoracic impedance vectors using ICD leads.

    Science.gov (United States)

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  4. Idioms-based Business Rule Extraction

    NARCIS (Netherlands)

    R Smit (Rob)

    2011-01-01

    htmlabstractThis thesis studies the extraction of embedded business rules, using the idioms of the used framework to identify them. Embedded business rules exist as source code in the software system and knowledge about them may get lost. Extraction of those business rules could make them accessible

  5. 42 CFR 412.428 - Publication of Updates to the inpatient psychiatric facility prospective payment system.

    Science.gov (United States)

    2010-10-01

    ... maintain the appropriate outlier percentage. (e) Describe the ICD-9-CM coding changes and DRG classification changes discussed in the annual update to the hospital inpatient prospective payment system...

  6. Risk of tinnitus in patients with sleep apnea: A nationwide, population-based, case-control study.

    Science.gov (United States)

    Koo, Malcolm; Hwang, Juen-Haur

    2017-09-01

    To investigate the risk of tinnitus in patients with sleep disturbance or sleep apnea. Case control study. We identified 21,798 middle-aged and elderly patients with otolaryngologist-diagnosed tinnitus between January 1, 2000, and December 31, 2012, from the Longitudinal Health Insurance Database 2000 of the Taiwan National Health Insurance Research Database. A total of 108,990 controls were also identified from the same database based on frequency-matching on 10-year age interval, sex, and year of index date of the cases. Diagnoses of sleep disturbance (International Classification of Diseases, 9th Revision, Clinical Modification [ICD-9-CM] codes 780.50, 780.52, 307.4) and sleep apnea (ICD-9-CM codes 780.51, 780.53, 780.57) in the cases and controls prior to the index date were assessed. The risks of tinnitus in patients with sleep disturbance and sleep apnea were separately evaluated with multivariate logistic regression analyses. The mean age of the total 130,788 patients was 59.8 years, and 47% of them were males. The risk of tinnitus was higher in patients with sleep disturbance compared to those without the condition (adjusted odds ratio [OR] = 1.13, 95% confidence interval [CI] [95% CI] = 1.11-1.17), and the risk of tinnitus was higher in patients with sleep apnea compared to those without the condition (adjusted OR = 1.36, 95% CI = 1.16-1.60). In this population-based, case-control study, the risk of tinnitus was found to be significantly higher among middle-aged and elderly Taiwanese patients with sleep disturbances, especially with sleep apnea. 3b. Laryngoscope, 127:2171-2175, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Do coder characteristics influence validity of ICD-10 hospital discharge data?

    Directory of Open Access Journals (Sweden)

    Beck Cynthia A

    2010-04-01

    Full Text Available Abstract Background Administrative data are widely used to study health systems and make important health policy decisions. Yet little is known about the influence of coder characteristics on administrative data validity in these studies. Our goal was to describe the relationship between several measures of validity in coded hospital discharge data and 1 coders' volume of coding (≥13,000 vs. Methods This descriptive study examined 6 indicators of face validity in ICD-10 coded discharge records from 4 hospitals in Calgary, Canada between April 2002 and March 2007. Specifically, mean number of coded diagnoses, procedures, complications, Z-codes, and codes ending in 8 or 9 were compared by coding volume and employment status, as well as hospital type. The mean number of diagnoses was also compared across coder characteristics for 6 major conditions of varying complexity. Next, kappa statistics were computed to assess agreement between discharge data and linked chart data reabstracted by nursing chart reviewers. Kappas were compared across coder characteristics. Results 422,618 discharge records were coded by 59 coders during the study period. The mean number of diagnoses per record decreased from 5.2 in 2002/2003 to 3.9 in 2006/2007, while the number of records coded annually increased from 69,613 to 102,842. Coders at the tertiary hospital coded the most diagnoses (5.0 compared with 3.9 and 3.8 at other sites. There was no variation by coder or site characteristics for any other face validity indicator. The mean number of diagnoses increased from 1.5 to 7.9 with increasing complexity of the major diagnosis, but did not vary with coder characteristics. Agreement (kappa between coded data and chart review did not show any consistent pattern with respect to coder characteristics. Conclusions This large study suggests that coder characteristics do not influence the validity of hospital discharge data. Other jurisdictions might benefit from

  8. 75 FR 53202 - Diseases Associated With Exposure to Certain Herbicide Agents (Hairy Cell Leukemia and Other...

    Science.gov (United States)

    2010-08-31

    ... ICD-9-CM Medical Terminology and Codes One commenter expressed concern that VA regulations do not... Chapter of the American Parkinson Disease Association, Froedtert & The Medical College of Wisconsin, and...

  9. Harmonisation of ICD-11 and DSM-V: opportunities and challenges.

    Science.gov (United States)

    First, Michael B

    2009-11-01

    Differences in the ICD-10 and DSM-IV definitions for the same disorder impede international communication and research efforts. The forthcoming parallel development of DSM-V and ICD-11 offers an opportunity to harmonise the two classifications. This paper aims to facilitate the harmonisation process by identifying diagnostic differences between the two systems. DSM-IV-TR criteria sets and the ICD-10 Diagnostic Criteria for Research were compared and categorised into those with identical definitions, those with conceptually based differences and those in which differences are not conceptually based and appear to be unintentional. Of the 176 criteria sets in both systems, only one, transient tic disorder, is identical. Twenty-one per cent had conceptually based differences and 78% had non-conceptually based differences. Harmonisation of criteria sets, especially those with non-conceptually based differences, should be prioritised in the DSM-V and ICD-11 development process. Prior experience with the DSM-IV and ICD-10 harmonisation effort suggests that for the process to be successful steps should be taken as early as possible.

  10. Validation of ICDPIC software injury severity scores using a large regional trauma registry.

    Science.gov (United States)

    Greene, Nathaniel H; Kernic, Mary A; Vavilala, Monica S; Rivara, Frederick P

    2015-10-01

    Administrative or quality improvement registries may or may not contain the elements needed for investigations by trauma researchers. International Classification of Diseases Program for Injury Categorisation (ICDPIC), a statistical program available through Stata, is a powerful tool that can extract injury severity scores from ICD-9-CM codes. We conducted a validation study for use of the ICDPIC in trauma research. We conducted a retrospective cohort validation study of 40,418 patients with injury using a large regional trauma registry. ICDPIC-generated AIS scores for each body region were compared with trauma registry AIS scores (gold standard) in adult and paediatric populations. A separate analysis was conducted among patients with traumatic brain injury (TBI) comparing the ICDPIC tool with ICD-9-CM embedded severity codes. Performance in characterising overall injury severity, by the ISS, was also assessed. The ICDPIC tool generated substantial correlations in thoracic and abdominal trauma (weighted κ 0.87-0.92), and in head and neck trauma (weighted κ 0.76-0.83). The ICDPIC tool captured TBI severity better than ICD-9-CM code embedded severity and offered the advantage of generating a severity value for every patient (rather than having missing data). Its ability to produce an accurate severity score was consistent within each body region as well as overall. The ICDPIC tool performs well in classifying injury severity and is superior to ICD-9-CM embedded severity for TBI. Use of ICDPIC demonstrates substantial efficiency and may be a preferred tool in determining injury severity for large trauma datasets, provided researchers understand its limitations and take caution when examining smaller trauma datasets. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Clinical coding of prospectively identified paediatric adverse drug reactions--a retrospective review of patient records.

    Science.gov (United States)

    Bellis, Jennifer R; Kirkham, Jamie J; Nunn, Anthony J; Pirmohamed, Munir

    2014-12-17

    National Health Service (NHS) hospitals in the UK use a system of coding for patient episodes. The coding system used is the International Classification of Disease (ICD-10). There are ICD-10 codes which may be associated with adverse drug reactions (ADRs) and there is a possibility of using these codes for ADR surveillance. This study aimed to determine whether ADRs prospectively identified in children admitted to a paediatric hospital were coded appropriately using ICD-10. The electronic admission abstract for each patient with at least one ADR was reviewed. A record was made of whether the ADR(s) had been coded using ICD-10. Of 241 ADRs, 76 (31.5%) were coded using at least one ICD-10 ADR code. Of the oncology ADRs, 70/115 (61%) were coded using an ICD-10 ADR code compared with 6/126 (4.8%) non-oncology ADRs (difference in proportions 56%, 95% CI 46.2% to 65.8%; p codes as a single means of detection. Data derived from administrative healthcare databases are not reliable for identifying ADRs by themselves, but may complement other methods of detection.

  12. SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lasio, G; Yi, B; Zhou, J; Lin, M [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

  13. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel.

    Science.gov (United States)

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives: This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p  DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11.

  14. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel

    Science.gov (United States)

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    ABSTRACT Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives:This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11. PMID:29163862

  15. The disclosure of diagnosis codes can breach research participants' privacy.

    Science.gov (United States)

    Loukides, Grigorios; Denny, Joshua C; Malin, Bradley

    2010-01-01

    De-identified clinical data in standardized form (eg, diagnosis codes), derived from electronic medical records, are increasingly combined with research data (eg, DNA sequences) and disseminated to enable scientific investigations. This study examines whether released data can be linked with identified clinical records that are accessible via various resources to jeopardize patients' anonymity, and the ability of popular privacy protection methodologies to prevent such an attack. The study experimentally evaluates the re-identification risk of a de-identified sample of Vanderbilt's patient records involved in a genome-wide association study. It also measures the level of protection from re-identification, and data utility, provided by suppression and generalization. Privacy protection is quantified using the probability of re-identifying a patient in a larger population through diagnosis codes. Data utility is measured at a dataset level, using the percentage of retained information, as well as its description, and at a patient level, using two metrics based on the difference between the distribution of Internal Classification of Disease (ICD) version 9 codes before and after applying privacy protection. More than 96% of 2800 patients' records are shown to be uniquely identified by their diagnosis codes with respect to a population of 1.2 million patients. Generalization is shown to reduce further the percentage of de-identified records by less than 2%, and over 99% of the three-digit ICD-9 codes need to be suppressed to prevent re-identification. Popular privacy protection methods are inadequate to deliver a sufficiently protected and useful result when sharing data derived from complex clinical systems. The development of alternative privacy protection models is thus required.

  16. Heart failure severity, inappropriate ICD therapy, and novel ICD programming: a MADIT-RIT substudy.

    Science.gov (United States)

    Daimee, Usama A; Vermilye, Katherine; Rosero, Spencer; Schuger, Claudio D; Daubert, James P; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Moss, Arthur J; Kutyifa, Valentina

    2017-12-01

    The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF. © 2017 Wiley Periodicals, Inc.

  17. Coding paediatric outpatient data to provide health planners with information on children with chronic conditions and disabilities.

    Science.gov (United States)

    Craig, Elizabeth; Kerr, Neal; McDonald, Gabrielle

    2017-03-01

    In New Zealand, there is a paucity of information on children with chronic conditions and disabilities (CCD). One reason is that many are managed in hospital outpatients where diagnostic coding of health-care events does not occur. This study explores the feasibility of coding paediatric outpatient data to provide health planners with information on children with CCD. Thirty-seven clinicians from six District Health Boards (DHBs) trialled coding over 12 weeks. In five DHBs, the International Classification of Diseases and Related Health Problems, 10th Edition, Australian Modification (ICD-10-AM) and Systematised Nomenclature of Medicine Clinical Terms (SNOMED-CT) were trialled for 6 weeks each. In one DHB, ICD-10-AM was trialled for 12 weeks. A random sample (30%) of ICD-10-AM coded events were also coded by clinical coders. A mix of paper and electronic methods were used. In total 2,604 outpatient events were coded in ICD-10-AM and 693 in SNOMED-CT. Dual coding occurred for 770 (29.6%) ICD-10-AM events. Overall, 34% of ICD-10-AM and 40% of SNOMED-CT events were for developmental and behavioural disorders. Chronic medical conditions were also common. Clinicians were concerned about the workload impacts, particularly for paper-based methods. Coder's were concerned about clinician's adherence to coding guidelines and the poor quality of documentation in some notes. Coded outpatient data could provide planners with a rich source of information on children with CCD. However, coding is also resource intensive. Thus its costs need to be weighed against the costs of managing a much larger health budget using very limited information. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  18. Flexible patient information search and retrieval framework: pilot implementation

    Science.gov (United States)

    Erdal, Selnur; Catalyurek, Umit V.; Saltz, Joel; Kamal, Jyoti; Gurcan, Metin N.

    2007-03-01

    Medical centers collect and store significant amount of valuable data pertaining to patients' visit in the form of medical free-text. In addition, standardized diagnosis codes (International Classification of Diseases, Ninth Revision, Clinical Modification: ICD9-CM) related to those dictated reports are usually available. In this work, we have created a framework where image searches could be initiated through a combination of free-text reports as well as ICD9 codes. This framework enables more comprehensive search on existing large sets of patient data in a systematic way. The free text search is enriched by computer-aided inclusion of additional search terms enhanced by a thesaurus. This combination of enriched search allows users to access to a larger set of relevant results from a patient-centric PACS in a simpler way. Therefore, such framework is of particular use in tasks such as gathering images for desired patient populations, building disease models, and so on. As the motivating application of our framework, we implemented a search engine. This search engine processed two years of patient data from the OSU Medical Center's Information Warehouse and identified lung nodule location information using a combination of UMLS Meta-Thesaurus enhanced text report searches along with ICD9 code searches on patients that have been discharged. Five different queries with various ICD9 codes involving lung cancer were carried out on 172552 cases. Each search was completed under a minute on average per ICD9 code and the inclusion of UMLS thesaurus increased the number of relevant cases by 45% on average.

  19. Methodological approaches based on business rules

    OpenAIRE

    Anca Ioana ANDREESCU; Adina UTA

    2008-01-01

    Business rules and business processes are essential artifacts in defining the requirements of a software system. Business processes capture business behavior, while rules connect processes and thus control processes and business behavior. Traditionally, rules are scattered inside application code. This approach makes it very difficult to change rules and shorten the life cycle of the software system. Because rules change more quickly than the application itself, it is desirable to externalize...

  20. Risk of Suicide Attempt in Poststroke Patients: A Population-Based Cohort Study.

    Science.gov (United States)

    Harnod, Tomor; Lin, Cheng-Li; Kao, Chia-Hung

    2018-01-10

    This nationwide population-based cohort study evaluated the risk of and risk factors for suicide attempt in poststroke patients in Taiwan. The poststroke and nonstroke cohorts consisted of 713 690 patients and 1 426 009 controls, respectively. Adults (aged >18 years) who received new stroke diagnoses according to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM ; codes 430-438) between 2000 and 2011 were included in the poststroke cohort. We calculated the adjusted hazard ratio for suicide attempt ( ICD-9-CM codes E950-E959) after adjustment for age, sex, monthly income, urbanization level, occupation category, and various comorbidities. Kaplan-Meier analysis was used to measure the cumulative incidence of suicide attempt, and the Fine and Gray method was used as a competing event when estimating death subhazard ratios and 95% confidence intervals between groups. The cumulative incidence of suicide attempt was higher in the poststroke cohort, and the adjusted hazard ratio of suicide attempt was 2.20 (95% confidence interval, 2.04-2.37) compared with that of the controls. The leading risk factors for poststroke suicide attempt were earning low monthly income (US dollars), living in less urbanized regions, doing manual labor, and having a stroke before age 50 years. The attempted suicide risk did not differ significantly between male and female patients in this study. These results convey crucial information to clinicians and governments for preventing suicide attempt in poststroke patients in Taiwan and other Asian countries. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  1. An Ensemble Learning Based Framework for Traditional Chinese Medicine Data Analysis with ICD-10 Labels

    Directory of Open Access Journals (Sweden)

    Gang Zhang

    2015-01-01

    Full Text Available Objective. This study aims to establish a model to analyze clinical experience of TCM veteran doctors. We propose an ensemble learning based framework to analyze clinical records with ICD-10 labels information for effective diagnosis and acupoints recommendation. Methods. We propose an ensemble learning framework for the analysis task. A set of base learners composed of decision tree (DT and support vector machine (SVM are trained by bootstrapping the training dataset. The base learners are sorted by accuracy and diversity through nondominated sort (NDS algorithm and combined through a deep ensemble learning strategy. Results. We evaluate the proposed method with comparison to two currently successful methods on a clinical diagnosis dataset with manually labeled ICD-10 information. ICD-10 label annotation and acupoints recommendation are evaluated for three methods. The proposed method achieves an accuracy rate of 88.2%  ±  2.8% measured by zero-one loss for the first evaluation session and 79.6%  ±  3.6% measured by Hamming loss, which are superior to the other two methods. Conclusion. The proposed ensemble model can effectively model the implied knowledge and experience in historic clinical data records. The computational cost of training a set of base learners is relatively low.

  2. Periodontitis as a Modifiable Risk Factor for Dementia: A Nationwide Population-Based Cohort Study.

    Science.gov (United States)

    Lee, Yao-Tung; Lee, Hsin-Chien; Hu, Chaur-Jongh; Huang, Li-Kai; Chao, Shu-Ping; Lin, Chia-Pei; Su, Emily Chia-Yu; Lee, Yi-Chen; Chen, Chu-Chieh

    2017-02-01

    To determine whether periodontitis is a modifiable risk factor for dementia. Prospective cohort study. National Health Insurance Research Database in Taiwan. Individuals aged 65 and older with periodontitis (n = 3,028) and an age- and sex-matched control group (n = 3,028). Individuals with periodontitis were compared age- and sex-matched controls with for incidence density and hazard ratio (HR) of new-onset dementia. Periodontitis was defined according to International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes 523.3-5 diagnosed by dentists. To ensure diagnostic validity, only those who had concurrently received antibiotic therapies, periodontal treatment other than scaling, or scaling more than twice per year performed by certified dentists were included. Dementia was defined according to ICD-9-CM codes 290.0-290.4, 294.1, 331.0-331.2. After adjustment for confounding factors, the risk of developing dementia was calculated to be higher for participants with periodontitis (HR = 1.16, 95% confidence interval = 1.01-1.32, P = .03) than for those without. Periodontitis is associated with greater risk of developing dementia. Periodontal infection is treatable, so it might be a modifiable risk factor for dementia. Clinicians must devote greater attention to this potential association in an effort to develop new preventive and therapeutic strategies for dementia. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  3. An evaluation of ICD-11 posttraumatic stress disorder criteria in two samples of adolescents and young adults exposed to mass shootings: factor analysis and comparisons to ICD-10 and DSM-IV.

    Science.gov (United States)

    Haravuori, Henna; Kiviruusu, Olli; Suomalainen, Laura; Marttunen, Mauri

    2016-05-12

    The proposed posttraumatic stress disorder (PTSD) criteria for the International Classification of Diseases (ICD) 11th revision are simpler than the criteria in ICD-10, DSM-IV or DSM-5. The aim of this study was to evaluate the ICD-11 PTSD factor structure in samples of young people, and to compare PTSD prevalence rates and diagnostic agreement between the different diagnostic systems. Possible differences in clinical characteristics of the PTSD cases identified by ICD-11, ICD-10 and DSM-IV are explored. Two samples of adolescents and young adults were followed after exposure to similar mass shooting incidents in their schools. Semi-structured diagnostic interviews were performed to assess psychiatric diagnoses and PTSD symptom scores (N = 228, mean age 17.6 years). PTSD symptom item scores were used to compose diagnoses according to the different classification systems. Confirmatory factor analyses indicated that the proposed ICD-11 PTSD symptoms represented two rather than three factors; re-experiencing and avoidance symptoms comprised one factor and hyperarousal symptoms the other factor. In the studied samples, the three-factor ICD-11 criteria identified 51 (22.4%) PTSD cases, the two-factor ICD-11 identified 56 (24.6%) cases and the DSM-IV identified 43 (18.9%) cases, while the number of cases identified by ICD-10 was larger, being 85 (37.3%) cases. Diagnostic agreement of the ICD-11 PTSD criteria with ICD-10 and DSM-IV was moderate, yet the diagnostic agreement turned to be good when an impairment criterion was imposed on ICD-10. Compared to ICD-11, ICD-10 identified cases with less severe trauma exposure and posttraumatic symptoms and DSM-IV identified cases with less severe trauma exposure. The findings suggest that the two-factor model of ICD-11 PTSD is preferable to the three-factor model. The proposed ICD-11 criteria are more restrictive compared to the ICD-10 criteria. There were some differences in the clinical characteristics of the PTSD cases

  4. QEFSM model and Markov Algorithm for translating Quran reciting rules into Braille code

    Directory of Open Access Journals (Sweden)

    Abdallah M. Abualkishik

    2015-07-01

    Full Text Available The Holy Quran is the central religious verbal text of Islam. Muslims are expected to read, understand, and apply the teachings of the Holy Quran. The Holy Quran was translated to Braille code as a normal Arabic text without having its reciting rules included. It is obvious that the users of this transliteration will not be able to recite the Quran the right way. Through this work, Quran Braille Translator (QBT presents a specific translator to translate Quran verses and their reciting rules into the Braille code. Quran Extended Finite State Machine (QEFSM model is proposed through this study as it is able to detect the Quran reciting rules (QRR from the Quran text. Basis path testing was used to evaluate the inner work for the model by checking all the test cases for the model. Markov Algorithm (MA was used for translating the detected QRR and Quran text into the matched Braille code. The data entries for QBT are Arabic letters and diacritics. The outputs of this study are seen in the double lines of Braille symbols; the first line is the proposed Quran reciting rules and the second line is for the Quran scripts.

  5. Hypochondriasis: considerations for ICD-11

    Directory of Open Access Journals (Sweden)

    Odile A. van den Heuvel

    2014-01-01

    Full Text Available The World Health Organization (WHO is currently revisiting the ICD. In the 10th version of the ICD, approved in 1990, hypochondriacal symptoms are described in the context of both the primary condition hypochondriacal disorder and as secondary symptoms within a range of other mental disorders. Expansion of the research base since 1990 makes a critical evaluation and revision of both the definition and classification of hypochondriacal disorder timely. This article addresses the considerations reviewed by members of the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders in their proposal for the description and classification of hypochondriasis. The proposed revision emphasizes the phenomenological overlap with both anxiety disorders (e.g., fear, hypervigilance to bodily symptoms, and avoidance and obsessive-compulsive and related disorders (e.g., preoccupation and repetitive behaviors and the distinction from the somatoform disorders (presence of somatic symptom is not a critical characteristic. This revision aims to improve clinical utility by enabling better recognition and treatment of patients with hypochondriasis within the broad range of global health care settings.

  6. ICD-11 (JLMMS) and SCT Inter-Operation.

    Science.gov (United States)

    Mamou, Marzouk; Rector, Alan; Schulz, Stefan; Campbell, James; Solbrig, Harold; Rodrigues, Jean-Marie

    2016-01-01

    The goal of this work is to contribute to a smooth and semantically sound inter-operability between the ICD-11 (International Classification of Diseases-11th revision Joint Linearization for Mortality, Morbidity and Statistics) and SNOMED CT (SCT). To guarantee such inter-operation between a classification, characterized by a single hierarchy of mutually exclusive and exhaustive classes, as is the JLMMS successor of ICD-10 on the one hand, and the multi-hierarchical, ontology-based clinical terminology SCT on the other hand, we use ontology axioms that logically express generalizable truths. This is expressed by the compositional grammar of SCT, together with queries on axiomsof SCT. We test the feasibility of the method on the circulatory chapter of ICD-11 JLMMS and present limitations and results.

  7. Use of hospital discharge data to monitor uterine rupture--Massachusetts, 1990-1997.

    Science.gov (United States)

    2000-03-31

    Uterine rupture (UR), a potentially life-threatening condition for both mother and infant, occurs in vaginal birth after cesarean section (VBAC) (1-4). During 1990-1997, the proportion of vaginal deliveries among women who had previous cesarean sections (CS) in Massachusetts increased 50%, from 22.3% to 33.5% (5). Concern about a corresponding increase in UR prompted the Massachusetts Department of Public Health and CDC to initiate a state-wide investigation that included an assessment of the validity and reliability of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) (6), codes in hospital discharge data to identify UR cases. This report summarizes the results of the investigation, which indicate that ICD-9-CM codes related to UR, designed before increased concern about UR, lack adequate specificity for UR surveillance and have not been applied consistently over time.

  8. ICD-11: a comprehensive picture of health, an update on the ICD-ICF joint use initiative.

    Science.gov (United States)

    Selb, Melissa; Kohler, Friedbert; Robinson Nicol, Molly Meri; Riberto, Marcelo; Stucki, Gerold; Kennedy, Cille; Üstün, Bedirhan

    2015-01-01

    This is a follow-up of the special report Towards the joint use of ICD and ICF: A call for contribution, published by the Journal of Rehabilitation Medicine in 2012, which introduced an initiative of using the International Classification of Diseases (ICD) and the International Classification of Functioning, Disability and Health (ICF) in a complementary way in clinical practice. Recognizing the merits of using the ICD and ICF jointly, the World Health Organization (WHO) introduced so-called functioning properties in the ICD-11. The first step in this ICD-ICF joint use initiative revealed 103 rehabilitation-relevant health conditions for which functioning properties were to be identified. Afterwards experts were recruited to identify the functioning properties for the health conditions for which no ICF Core Sets were available and all the functioning properties were integrated in the beta-version of ICD-11. The objective of this special report is to present the outcome of the recruitment and training of the contributing experts, and to provide an update on the current status of identifying functioning properties and their integration in ICD-11. Having functioning properties in the ICD-11 achieves a milestone in depicting health information in an integrated and comprehensive manner. Explicitly identifying functioning properties for specific health conditions further reinforces the importance of acquiring a broader and more meaningful picture of a person's health, and can guide clinical decision-making.

  9. Changing from a Rules-based to a Principles-based Accounting Logic: A Review

    Directory of Open Access Journals (Sweden)

    Marta Silva Guerreiro

    2014-06-01

    Full Text Available We explore influences on unlisted companies when Portugal moved from a code law, rules-based accounting system, to a principles-based accounting system of adapted International Financial Reporting Standards (IFRS. Institutionalisation of the new principles-based system was generally facilitated by a socio-economic and political context that increasingly supported IFRS logic. This helped central actors gain political opportunity, mobilise important allies, and accommodate major protagonists. The preparedness of unlisted companies to adopt the new IFRS-based accounting system voluntarily was explained by their desire to maintain social legitimacy. However, it was affected negatively by the embeddedness of rule-based practices in the ‘old’ prevailing institutional logic.

  10. Privacy rules for DNA databanks. Protecting coded 'future diaries'.

    Science.gov (United States)

    Annas, G J

    1993-11-17

    In privacy terms, genetic information is like medical information. But the information contained in the DNA molecule itself is more sensitive because it contains an individual's probabilistic "future diary," is written in a code that has only partially been broken, and contains information about an individual's parents, siblings, and children. Current rules for protecting the privacy of medical information cannot protect either genetic information or identifiable DNA samples stored in DNA databanks. A review of the legal and public policy rationales for protecting genetic privacy suggests that specific enforceable privacy rules for DNA databanks are needed. Four preliminary rules are proposed to govern the creation of DNA databanks, the collection of DNA samples for storage, limits on the use of information derived from the samples, and continuing obligations to those whose DNA samples are in the databanks.

  11. Nomenclature for congenital and paediatric cardiac disease: the International Paediatric and Congenital Cardiac Code (IPCCC) and the Eleventh Iteration of the International Classification of Diseases (ICD-11).

    Science.gov (United States)

    Franklin, Rodney C G; Béland, Marie J; Colan, Steven D; Walters, Henry L; Aiello, Vera D; Anderson, Robert H; Bailliard, Frédérique; Boris, Jeffrey R; Cohen, Meryl S; Gaynor, J William; Guleserian, Kristine J; Houyel, Lucile; Jacobs, Marshall L; Juraszek, Amy L; Krogmann, Otto N; Kurosawa, Hiromi; Lopez, Leo; Maruszewski, Bohdan J; St Louis, James D; Seslar, Stephen P; Srivastava, Shubhika; Stellin, Giovanni; Tchervenkov, Christo I; Weinberg, Paul M; Jacobs, Jeffrey P

    2017-12-01

    An internationally approved and globally used classification scheme for the diagnosis of CHD has long been sought. The International Paediatric and Congenital Cardiac Code (IPCCC), which was produced and has been maintained by the International Society for Nomenclature of Paediatric and Congenital Heart Disease (the International Nomenclature Society), is used widely, but has spawned many "short list" versions that differ in content depending on the user. Thus, efforts to have a uniform identification of patients with CHD using a single up-to-date and coordinated nomenclature system continue to be thwarted, even if a common nomenclature has been used as a basis for composing various "short lists". In an attempt to solve this problem, the International Nomenclature Society has linked its efforts with those of the World Health Organization to obtain a globally accepted nomenclature tree for CHD within the 11th iteration of the International Classification of Diseases (ICD-11). The International Nomenclature Society has submitted a hierarchical nomenclature tree for CHD to the World Health Organization that is expected to serve increasingly as the "short list" for all communities interested in coding for congenital cardiology. This article reviews the history of the International Classification of Diseases and of the IPCCC, and outlines the process used in developing the ICD-11 congenital cardiac disease diagnostic list and the definitions for each term on the list. An overview of the content of the congenital heart anomaly section of the Foundation Component of ICD-11, published herein in its entirety, is also included. Future plans for the International Nomenclature Society include linking again with the World Health Organization to tackle procedural nomenclature as it relates to cardiac malformations. By doing so, the Society will continue its role in standardising nomenclature for CHD across the globe, thereby promoting research and better outcomes for fetuses

  12. Postmortem ICD interrogation in mode of death classification.

    Science.gov (United States)

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  13. [Coding Causes of Death with IRIS Software. Impact in Navarre Mortality Statistic].

    Science.gov (United States)

    Floristán Floristán, Yugo; Delfrade Osinaga, Josu; Carrillo Prieto, Jesus; Aguirre Perez, Jesus; Moreno-Iribas, Conchi

    2016-08-02

    There are few studies that analyze changes in mortality statistics derived from the use of IRIS software, an automatic system for coding multiple causes of death and for the selection of the underlying cause of death, compared to manual coding. This study evaluated the impact of the use of IRIS in the Navarre mortality statistic. We proceeded to double coding 5,060 death certificates corresponding to residents in Navarra in 2014. We calculated coincidence between the two encodings for ICD10 chapters and for the list of causes of the Spanish National Statistics Institute (INE-102) and we estimated the change on mortality rates. IRIS automatically coded 90% of death certificates. The coincidence to 4 characters and in the same chapter of the CIE10 was 79.1% and 92.0%, respectively. Furthermore, coincidence with the short INE-102 list was 88.3%. Higher matches were found in death certificate of people under 65 years. In comparison with manual coding there was an increase in deaths from endocrine diseases (31%), mental disorders (19%) and disease of nervous system (9%), while a decrease of genitourinary system diseases was observed (21%). The coincidence at level of ICD10 chapters coding by IRIS in comparison to manual coding was 9 out of 10 deaths, similar to what is observed in other studies. The implementation of IRIS has led to increased of endocrine diseases, especially diabetes and hyperlipidaemia, and mental disorders, especially dementias.

  14. A comparison of ICD-11 and DSM criteria for posttraumatic stress disorder in two national samples of U.S. military veterans.

    Science.gov (United States)

    Wisco, Blair E; Marx, Brian P; Miller, Mark W; Wolf, Erika J; Krystal, John H; Southwick, Steven M; Pietrzak, Robert H

    2017-12-01

    The proposed ICD-11 criteria for posttraumatic stress disorder (PTSD) differ substantially from the DSM-5. ICD-11 eliminated several PTSD symptoms thought to be nonspecific, with the goal of reducing psychiatric comorbidities. However, this change also results in a narrower PTSD definition that may fail to capture individuals with clinically significant PTSD. The purpose of the current study was to compare prevalence and psychiatric comorbidities of DSM (IV/5) and ICD-11 PTSD. We evaluated concordance between DSM (IV/5) and ICD-11 PTSD diagnoses in a web survey of two nationally representative samples of U.S. military veterans (ns = 3517 and 1484). Lifetime and past-month PTSD symptoms were assessed with the DSM-IV-based PTSD Checklist-Specific Stressor version and the DSM-5-based PTSD Checklist-5. Psychiatric comorbidities were assessed using MINI Neuropsychiatric Interview modules. A significantly greater proportion of veterans met criteria for lifetime and past-month PTSD under DSM-IV/5 than under ICD-11. 21.8-35.9% of those who met criteria under DSM IV/5 did not meet under ICD-11, whereas only 2.4-7.1% of those who met under ICD-11 did not meet under DSM-IV/5. Psychiatric comorbidities did not significantly differ between DSM-IV/5 and ICD-11. This study relied upon self-report measures of PTSD, distress/impairment, and psychiatric comorbidities. The proposed ICD-11 criteria identify fewer PTSD cases than DSM-IV/5 without reducing psychiatric comorbidities. Veterans with clinically significant PTSD symptoms may not meet ICD-11 PTSD criteria, possibly affecting eligibility for healthcare, disability, and other services. The ICD-11 criteria could be revised to capture more PTSD cases before ICD-11 is published in 2018. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Improving the coding and classification of ambulance data through the application of International Classification of Disease 10th revision.

    Science.gov (United States)

    Cantwell, Kate; Morgans, Amee; Smith, Karen; Livingston, Michael; Dietze, Paul

    2014-02-01

    This paper aims to examine whether an adaptation of the International Classification of Disease (ICD) coding system can be applied retrospectively to final paramedic assessment data in an ambulance dataset with a view to developing more fine-grained, clinically relevant case definitions than are available through point-of-call data. Over 1.2 million case records were extracted from the Ambulance Victoria data warehouse. Data fields included dispatch code, cause (CN) and final primary assessment (FPA). Each FPA was converted to an ICD-10-AM code using word matching or best fit. ICD-10-AM codes were then converted into Major Diagnostic Categories (MDC). CN was aligned with the ICD-10-AM codes for external cause of morbidity and mortality. The most accurate results were obtained when ICD-10-AM codes were assigned using information from both FPA and CN. Comparison of cases coded as unconscious at point-of-call with the associated paramedic assessment highlighted the extra clinical detail obtained when paramedic assessment data are used. Ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Coding of ambulance data using ICD-10-AM allows for comparison of not only ambulance service users but also with other population groups. WHAT IS KNOWN ABOUT THE TOPIC? There is no reliable and standard coding and categorising system for paramedic assessment data contained in ambulance service databases. WHAT DOES THIS PAPER ADD? This study demonstrates that ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Representation of ambulance case types using ICD-10-AM-coded information obtained after paramedic assessment is more fine grained and clinically relevant than point-of-call data, which uses caller information before ambulance attendance. WHAT ARE THE IMPLICATIONS FOR PRACTITIONERS? This paper describes

  16. Constructing a classification of hypersensitivity/allergic diseases for ICD-11 by crowdsourcing the allergist community.

    Science.gov (United States)

    Tanno, L K; Calderon, M A; Goldberg, B J; Gayraud, J; Bircher, A J; Casale, T; Li, J; Sanchez-Borges, M; Rosenwasser, L J; Pawankar, R; Papadopoulos, N G; Demoly, P

    2015-06-01

    The global allergy community strongly believes that the 11th revision of the International Classification of Diseases (ICD-11) offers a unique opportunity to improve the classification and coding of hypersensitivity/allergic diseases via inclusion of a specific chapter dedicated to this disease area to facilitate epidemiological studies, as well as to evaluate the true size of the allergy epidemic. In this context, an international collaboration has decided to revise the classification of hypersensitivity/allergic diseases and to validate it for ICD-11 by crowdsourcing the allergist community. After careful comparison between ICD-10 and 11 beta phase linearization codes, we identified gaps and trade-offs allowing us to construct a classification proposal, which was sent to the European Academy of Allergy and Clinical Immunology (EAACI) sections, interest groups, executive committee as well as the World Allergy Organization (WAO), and American Academy of Allergy Asthma and Immunology (AAAAI) leaderships. The crowdsourcing process produced comments from 50 of 171 members contacted by e-mail. The classification proposal has also been discussed at face-to-face meetings with experts of EAACI sections and interest groups and presented in a number of business meetings during the 2014 EAACI annual congress in Copenhagen. As a result, a high-level complex structure of classification for hypersensitivity/allergic diseases has been constructed. The model proposed has been presented to the WHO groups in charge of the ICD revision. The international collaboration of allergy experts appreciates bilateral discussion and aims to get endorsement of their proposals for the final ICD-11. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Increased risk of acute angle closure in retinitis pigmentosa: a population-based case-control study.

    Directory of Open Access Journals (Sweden)

    Yu-Chieh Ko

    Full Text Available To investigate the association between retinitis pigmentosa (RP and acute angle closure during a 15-year follow-up period.Using the Taiwan Longitudinal Health Insurance Database 2000, we identified 382 RP patients based on the diagnostic code of RP (International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM 362.74 made during 1996-2010, excluding subjects under age of 20 years at diagnosis or subjects undergoing lens extraction before the index date. The control group included 3820 randomly selected non-RP subjects matched with the RP patients in age, gender and the index date of diagnosis. The incidence of acute angle closure during the study period was observed based on an ICD-9-CM code of 365.22. Cochran-Mantel-Haenszel test was used to determine the odds ratio (OR of having acute angle closure in RP patients.The mean age at the diagnosis of RP was 51.1 years (standard deviation [SD] 16.7. Acute angle closure occurred in 5 RP patients (1.3% and in 15 controls (0.4%. The mean age with the acute angle closure was 53.3 years (SD 8.0 in RP patients and 64.6 years (SD 8.4 in controls (P = 0.015. After adjusting for age, gender and comorbid disorders, RP patients had 3.64-fold (95% confidence interval [CI], 1.29-10.25, P<0.001 greater odds of having acute angle closure. After stratification for gender and age, the risk of acute angle closure in RP was higher in patients under age of 60 years (adjusted OR 11.84; 95% CI, 2.84-49.48 and male patients (adjusted OR 19.36; 95% CI, 3.43-109.40 (both P = 0.001.RP patients had increased risk of acute angle closure than controls. Contrary to the fact that angle closure disease is more prevalent in elderly females in general population, acute angle closure attack occurred earlier in life and the risk was higher in males among RP patients.

  18. Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management

    NARCIS (Netherlands)

    Olde Nordkamp, Louise R. A.; Brouwer, Tom F.; Barr, Craig; Theuns, Dominic A. M. J.; Boersma, Lucas V. A.; Johansen, Jens B.; Neuzil, Petr; Wilde, Arthur A. M.; Carter, Nathan; Husby, Michael; Lambiase, Pier D.; Knops, Reinoud E.

    2015-01-01

    The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate shocks have

  19. Identifying patients with severe sepsis using administrative claims: patient-level validation of the angus implementation of the international consensus conference definition of severe sepsis.

    Science.gov (United States)

    Iwashyna, Theodore J; Odden, Andrew; Rohde, Jeffrey; Bonham, Catherine; Kuhn, Latoya; Malani, Preeti; Chen, Lena; Flanders, Scott

    2014-06-01

    Severe sepsis is a common and costly problem. Although consistently defined clinically by consensus conference since 1991, there have been several different implementations of the severe sepsis definition using ICD-9-CM codes for research. We conducted a single center, patient-level validation of 1 common implementation of the severe sepsis definition, the so-called "Angus" implementation. Administrative claims for all hospitalizations for patients initially admitted to general medical services from an academic medical center in 2009-2010 were reviewed. On the basis of ICD-9-CM codes, hospitalizations were sampled for review by 3 internal medicine-trained hospitalists. Chart reviews were conducted with a structured instrument, and the gold standard was the hospitalists' summary clinical judgment on whether the patient had severe sepsis. Three thousand one hundred forty-six (13.5%) hospitalizations met ICD-9-CM criteria for severe sepsis by the Angus implementation (Angus-positive) and 20,142 (86.5%) were Angus-negative. Chart reviews were performed for 92 randomly selected Angus-positive and 19 randomly-selected Angus-negative hospitalizations. Reviewers had a κ of 0.70. The Angus implementation's positive predictive value was 70.7% [95% confidence interval (CI): 51.2%, 90.5%]. The negative predictive value was 91.5% (95% CI: 79.0%, 100%). The sensitivity was 50.4% (95% CI: 14.8%, 85.7%). Specificity was 96.3% (95% CI: 92.4%, 100%). Two alternative ICD-9-CM implementations had high positive predictive values but sensitivities of Angus implementation of the international consensus conference definition of severe sepsis offers a reasonable but imperfect approach to identifying patients with severe sepsis when compared with a gold standard of structured review of the medical chart by trained hospitalists.

  20. Automatic coding and selection of causes of death: an adaptation of Iris software for using in Brazil.

    Science.gov (United States)

    Martins, Renata Cristófani; Buchalla, Cassia Maria

    2015-01-01

    To prepare a dictionary in Portuguese for using in Iris and to evaluate its completeness for coding causes of death. Iniatially, a dictionary with all illness and injuries was created based on the International Classification of Diseases - tenth revision (ICD-10) codes. This dictionary was based on two sources: the electronic file of ICD-10 volume 1 and the data from Thesaurus of the International Classification of Primary Care (ICPC-2). Then, a death certificate sample from the Program of Improvement of Mortality Information in São Paulo (PRO-AIM) was coded manually and by Iris version V4.0.34, and the causes of death were compared. Whenever Iris was not able to code the causes of death, adjustments were made in the dictionary. Iris was able to code all causes of death in 94.4% death certificates, but only 50.6% were directly coded, without adjustments. Among death certificates that the software was unable to fully code, 89.2% had a diagnosis of external causes (chapter XX of ICD-10). This group of causes of death showed less agreement when comparing the coding by Iris to the manual one. The software performed well, but it needs adjustments and improvement in its dictionary. In the upcoming versions of the software, its developers are trying to solve the external causes of death problem.

  1. Examination of the accuracy of coding hospital-acquired pressure ulcer stages.

    Science.gov (United States)

    Coomer, Nicole M; McCall, Nancy T

    2013-01-01

    Pressure ulcers (PU) are considered harmful conditions that are reasonably prevented if accepted standards of care are followed. They became subject to the payment adjustment for hospitalacquired conditions (HACs) beginning October 1, 2008. We examined several aspects of the accuracy of coding for pressure ulcers under the Medicare Hospital-Acquired Condition Present on Admission (HAC-POA) Program. We used the "4010" claim format as a basis of reference to show some of the issues of the old format, such as the underreporting of pressure ulcer stages on pressure ulcer claims and how the underreporting varied by hospital characteristics. We then used the rate of Stage III and IV pressure ulcer HACs reported in the Hospital Cost and Utilization Project State Inpatient Databases data to look at the sensitivity of PU HAC-POA coding to the number of diagnosis fields. We examined Medicare claims data for FYs 2009 and 2010 to examine the degree that the presence of stage codes were underreported on pressure ulcer claims. We selected all claims with a secondary diagnosis code of pressure ulcer site (ICD-9 diagnosis codes 707.00-707.09) that were not reported as POA (POA of "N" or "U"). We then created a binary indicator for the presence of any pressure ulcer stage diagnosis code. We examine the percentage of claims with a diagnosis of a pressure ulcer site code with no accompanying pressure ulcer stage code. Our results point to underreporting of PU stages under the "4010" format and that the reporting of stage codes varied across hospital type and location. Further, our results indicate that under the "5010" format, a higher number of pressure ulcer HACs can be expected to be reported and we should expect to encounter a larger percentage of pressure ulcers incorrectly coded as POA under the new format. The combination of the capture of 25 diagnosis codes under the new "5010" format and the change from ICD-9 to ICD-10 will likely alleviate the observed underreporting of

  2. Association of the position of a hospital-acquired condition diagnosis code with changes in medicare severity diagnosis-related group assignment.

    Science.gov (United States)

    Johnson, Tricia; Kane, Jason M; Odwazny, Richard; McNutt, Robert

    2014-11-01

    Incentives to improve quality include paying less for adverse events, including the Centers for Medicare and Medicaid Services' policy to not pay additionally for events classified as hospital-acquired conditions (HACs). This policy is controversial, as variable coding practices at hospitals may lead to differences in the inclusion and position of HACs in the list of codes used for Medicare Severity Diagnosis-Related Group (MS-DRG) assignment. Evaluate changes in MS-DRG assignment for patients with an HAC and test the association of the position of an HAC in the list of International Classification of Diseases, 9th Revision (ICD-9) diagnosis codes with change in MS-DRG assignment. Retrospective analysis of patients discharged from hospital members of the University HealthSystem Consortium's Clinical Data Base between October 2007 and April 2008. Comparisons were made between the MS-DRG assigned when the HAC was not included in the list of ICD-9 diagnosis codes and the MS-DRG that would have been assigned had the HAC code been included in the assignment. Of the 7027 patients with an HAC, 13.8% changed MS-DRG assignment when the HAC was removed. An HAC in the second position versus third position or lower was associated with a 40-fold increase in the likelihood of MS-DRG change. The position of an HAC in the list of diagnosis codes, rather than the presence of an HAC, is associated with a change in MS-DRG assignment. HACs have little effect on reimbursement unless the HAC is in the second position and patients have minor severity of illness. © 2014 Society of Hospital Medicine.

  3. Primary ICD-therapy in patients with advanced heart failure: selection strategies and future trials.

    Science.gov (United States)

    Frankenstein, Lutz; Zugck, Christian; Nelles, Manfred; Schellberg, Dieter; Remppis, Andrew; Katus, Hugo

    2008-09-01

    For allocation of primary ICD-therapy, a possible lower limit of inclusion criteria--defining overly advanced heart failure--is less well investigated. Also, a multi-variable approach to stratification beyond ejection fraction (LVEF) appears warranted. We examined whether adding a selection limit of peak VO(2) based on real-life data for this high risk cohort. In our prospective clinical registry 1,926 patients with systolic CHF were recruited consecutively since 1994. Of these patients, 292 met the selection criteria described above. The mean age was 57.6 +/- 9.5 years, 83% were male, 37% had ischemic cardiomyopathy and 28% received primary ICD-therapy. All cause mortality was considered as end point. Median follow-up was 45 (18-86) months. ICD was not a significant predictor of outcome either for the entire population, or grouped according to aetiology of CHF. Still, 3-year mortality was 15% (ICD-patients) Vs. 28% (non-ICD-patients); P = 0.05; under combination medical therapy. Inversely, in ICD-patients medical combination therapy conveyed a significant survival benefit (P < 0.001). Consequently, the number-needed-to-treat was eight under combination therapy and the size estimate amounts to 300 patients for a prospective trial in this cohort. A cut-off of LVEF ICD-therapy. Our results indicate the need for a specific randomized trial in this cohort. The according mortality data and a size estimate are provided.

  4. SPATKIN: a simulator for rule-based modeling of biomolecular site dynamics on surfaces.

    Science.gov (United States)

    Kochanczyk, Marek; Hlavacek, William S; Lipniacki, Tomasz

    2017-11-15

    Rule-based modeling is a powerful approach for studying biomolecular site dynamics. Here, we present SPATKIN, a general-purpose simulator for rule-based modeling in two spatial dimensions. The simulation algorithm is a lattice-based method that tracks Brownian motion of individual molecules and the stochastic firing of rule-defined reaction events. Because rules are used as event generators, the algorithm is network-free, meaning that it does not require to generate the complete reaction network implied by rules prior to simulation. In a simulation, each molecule (or complex of molecules) is taken to occupy a single lattice site that cannot be shared with another molecule (or complex). SPATKIN is capable of simulating a wide array of membrane-associated processes, including adsorption, desorption and crowding. Models are specified using an extension of the BioNetGen language, which allows to account for spatial features of the simulated process. The C ++ source code for SPATKIN is distributed freely under the terms of the GNU GPLv3 license. The source code can be compiled for execution on popular platforms (Windows, Mac and Linux). An installer for 64-bit Windows and a macOS app are available. The source code and precompiled binaries are available at the SPATKIN Web site (http://pmbm.ippt.pan.pl/software/spatkin). spatkin.simulator@gmail.com. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  5. 75 FR 73091 - Medicare Program; Town Hall Meeting on the Fiscal Year 2012 Applications for Add-on Payments for...

    Science.gov (United States)

    2010-11-29

    ... devices and new technology ambulatory payment classification (APC) group assignments for new services... of diagnosis-related group (DRG) assignment and requesting new ICD-9-CM codes under the IPPS... of new services to new technology ambulatory payment classification (APC) groups, the Informational...

  6. 26 CFR 1.997-1 - Special rules for subchapter C of the Code.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Special rules for subchapter C of the Code. 1.997-1 Section 1.997-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International Sales Corporations § 1.997-1 Special rules for...

  7. INCIDENCE AND PREVALENCE OF ACROMEGALY IN THE UNITED STATES: A CLAIMS-BASED ANALYSIS.

    Science.gov (United States)

    Broder, Michael S; Chang, Eunice; Cherepanov, Dasha; Neary, Maureen P; Ludlam, William H

    2016-11-01

    Acromegaly, a rare endocrine disorder, results from excessive growth hormone secretion, leading to multisystem-associated morbidities. Using 2 large nationwide databases, we estimated the annual incidence and prevalence of acromegaly in the U.S. We used 2008 to 2013 data from the Truven Health MarketScan ® Commercial Claims and Encounters Database and IMS Health PharMetrics healthcare insurance claims databases, with health plan enrollees acromegaly (International Classification of Diseases, 9th Revision, Clinical Modification Code [ICD-9CM] 253.0), or 1 claim with acromegaly and 1 claim for pituitary tumor, pituitary surgery, or cranial stereotactic radiosurgery. Annual incidence was calculated for each year from 2009 to 2013, and prevalence in 2013. Estimates were stratified by age and sex. Incidence was up to 11.7 cases per million person-years (PMPY) in MarketScan and 9.6 cases PMPY in PharMetrics. Rates were similar by sex but typically lowest in ≤17 year olds and higher in >24 year olds. The prevalence estimates were 87.8 and 71.0 per million per year in MarketScan and PharMetrics, respectively. Prevalence consistently increased with age but was similar by sex in each database. The current U.S. incidence of acromegaly may be up to 4 times higher and prevalence may be up to 50% higher than previously reported in European studies. Our findings correspond with the estimates reported by a recent U.S. study that used a single managed care database, supporting the robustness of these estimates in this population. Our study indicates there are approximately 3,000 new cases of acromegaly per year, with a prevalence of about 25,000 acromegaly patients in the U.S. CT = computed tomography GH = growth hormone IGF-1 = insulin-like growth factor 1 ICD-9-CM Code = International Classification of Diseases, 9th Revision, Clinical Modification Codes MRI = magnetic resonance imaging PMPY = per million person-years.

  8. Implications of ICD-10 for Sarcopenia Clinical Practice and Clinical Trials: Report by the International Conference on Frailty and Sarcopenia Research Task Force.

    Science.gov (United States)

    Vellas, B; Fielding, R A; Bens, C; Bernabei, R; Cawthon, P M; Cederholm, T; Cruz-Jentoft, A J; Del Signore, S; Donahue, S; Morley, J; Pahor, M; Reginster, J-Y; Rodriguez Mañas, L; Rolland, Y; Roubenoff, R; Sinclair, A; Cesari, M

    2018-01-01

    Establishment of an ICD-10-CM code for sarcopenia in 2016 was an important step towards reaching international consensus on the need for a nosological framework of age-related skeletal muscle decline. The International Conference on Frailty and Sarcopenia Research Task Force met in April 2017 to discuss the meaning, significance, and barriers to the implementation of the new code as well as strategies to accelerate development of new therapies. Analyses by the Sarcopenia Definitions and Outcomes Consortium are underway to develop quantitative definitions of sarcopenia. A consensus conference is planned to evaluate this analysis. The Task Force also discussed lessons learned from sarcopenia trials that could be applied to future trials, as well as lessons from the osteoporosis field, a clinical condition with many constructs similar to sarcopenia and for which ad hoc treatments have been developed and approved by regulatory agencies.

  9. Evaluation of the Components of the North Carolina Syndromic Surveillance System Heat Syndrome Case Definition.

    Science.gov (United States)

    Harduar Morano, Laurel; Waller, Anna E

    To improve heat-related illness surveillance, we evaluated and refined North Carolina's heat syndrome case definition. We analyzed North Carolina emergency department (ED) visits during 2012-2014. We evaluated the current heat syndrome case definition (ie, keywords in chief complaint/triage notes or International Classification of Diseases, Ninth Revision, Clinical Modification [ ICD-9-CM] codes) and additional heat-related inclusion and exclusion keywords. We calculated the positive predictive value and sensitivity of keyword-identified ED visits and manually reviewed ED visits to identify true positives and false positives. The current heat syndrome case definition identified 8928 ED visits; additional inclusion keywords identified another 598 ED visits. Of 4006 keyword-identified ED visits, 3216 (80.3%) were captured by 4 phrases: "heat ex" (n = 1674, 41.8%), "overheat" (n = 646, 16.1%), "too hot" (n = 594, 14.8%), and "heatstroke" (n = 302, 7.5%). Among the 267 ED visits identified by keyword only, a burn diagnosis or the following keywords resulted in a false-positive rate >95%: "burn," "grease," "liquid," "oil," "radiator," "antifreeze," "hot tub," "hot spring," and "sauna." After applying the revised inclusion and exclusion criteria, we identified 9132 heat-related ED visits: 2157 by keyword only, 5493 by ICD-9-CM code only, and 1482 by both (sensitivity = 27.0%, positive predictive value = 40.7%). Cases identified by keywords were strongly correlated with cases identified by ICD-9-CM codes (rho = .94, P definition through the use of additional inclusion and exclusion criteria substantially improved the accuracy of the surveillance system. Other jurisdictions may benefit from refining their heat syndrome case definition.

  10. Advanced GF(32) nonbinary LDPC coded modulation with non-uniform 9-QAM outperforming star 8-QAM.

    Science.gov (United States)

    Liu, Tao; Lin, Changyu; Djordjevic, Ivan B

    2016-06-27

    In this paper, we first describe a 9-symbol non-uniform signaling scheme based on Huffman code, in which different symbols are transmitted with different probabilities. By using the Huffman procedure, prefix code is designed to approach the optimal performance. Then, we introduce an algorithm to determine the optimal signal constellation sets for our proposed non-uniform scheme with the criterion of maximizing constellation figure of merit (CFM). The proposed nonuniform polarization multiplexed signaling 9-QAM scheme has the same spectral efficiency as the conventional 8-QAM. Additionally, we propose a specially designed GF(32) nonbinary quasi-cyclic LDPC code for the coded modulation system based on the 9-QAM non-uniform scheme. Further, we study the efficiency of our proposed non-uniform 9-QAM, combined with nonbinary LDPC coding, and demonstrate by Monte Carlo simulation that the proposed GF(23) nonbinary LDPC coded 9-QAM scheme outperforms nonbinary LDPC coded uniform 8-QAM by at least 0.8dB.

  11. A multi-physics code system based on ANC9, VIPRE-W and BOA for CIPS evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B.; Sung, Y.; Secker, J.; Beard, C.; Hilton, P.; Wang, G.; Oelrich, R.; Karoutas, Z.; Sung, Y. [Westinghouse Electric Company LLC, Pittsburgh (United States)

    2011-07-01

    This paper summarizes the development of a multi-physics code system for evaluation of Crud Induced Power Shift (CIPS) phenomenon experienced in some Pressurized Water Reactors (PWR). CIPS is an unexpected change in reactor core axial power distribution, caused by boron compounds in crud deposited in the high power fuel assemblies undergoing subcooled boiling. As part of the Consortium for Advanced Simulation of Light Water Reactors (CASL) sponsored by the US Department of Energy (DOE), this paper describes the initial linkage and application of a multi-physics code system ANC9/VIPRE-W/BOA for evaluating changes in core power distributions due to boron deposited in crud. The initial linkage of the code system along with the application results will be the base for the future CASL development. (author)

  12. A multi-physics code system based on ANC9, VIPRE-W and BOA for CIPS evaluation

    International Nuclear Information System (INIS)

    Zhang, B.; Sung, Y.; Secker, J.; Beard, C.; Hilton, P.; Wang, G.; Oelrich, R.; Karoutas, Z.; Sung, Y.

    2011-01-01

    This paper summarizes the development of a multi-physics code system for evaluation of Crud Induced Power Shift (CIPS) phenomenon experienced in some Pressurized Water Reactors (PWR). CIPS is an unexpected change in reactor core axial power distribution, caused by boron compounds in crud deposited in the high power fuel assemblies undergoing subcooled boiling. As part of the Consortium for Advanced Simulation of Light Water Reactors (CASL) sponsored by the US Department of Energy (DOE), this paper describes the initial linkage and application of a multi-physics code system ANC9/VIPRE-W/BOA for evaluating changes in core power distributions due to boron deposited in crud. The initial linkage of the code system along with the application results will be the base for the future CASL development. (author)

  13. Accuracy of Administrative Billing Codes to Detect Urinary Tract Infection Hospitalizations

    Science.gov (United States)

    Hall, Matthew; Auger, Katherine A.; Hain, Paul D.; Jerardi, Karen E.; Myers, Angela L.; Rahman, Suraiya S.; Williams, Derek J.; Shah, Samir S.

    2011-01-01

    BACKGROUND: Hospital billing data are frequently used for quality measures and research, but the accuracy of the use of discharge codes to identify urinary tract infections (UTIs) is unknown. OBJECTIVE: To determine the accuracy of International Classification of Diseases, 9th revision (ICD-9) discharge codes to identify children hospitalized with UTIs. METHODS: This multicenter study conducted in 5 children's hospitals included children aged 3 days to 18 years who had been admitted to the hospital, undergone a urinalysis or urine culture, and discharged from the hospital. Data were obtained from the pediatric health information system database and medical record review. With the use of 2 gold-standard methods, the positive predictive value (PPV) was calculated for individual and combined UTI codes and for common UTI identification strategies. PPV was measured for all groupings for which the UTI code was the principal discharge diagnosis. RESULTS: There were 833 patients in the study. The PPV was 50.3% with the use of the gold standard of laboratory-confirmed UTIs but increased to 85% with provider confirmation. Restriction of the study cohort to patients with a principle diagnosis of UTI improved the PPV for laboratory-confirmed UTI (61.2%) and provider-confirmed UTI (93.2%), as well as the ability to benchmark performance. Other common identification strategies did not markedly affect the PPV. CONCLUSIONS: ICD-9 codes can be used to identify patients with UTIs but are most accurate when UTI is the principal discharge diagnosis. The identification strategies reported in this study can be used to improve the accuracy and applicability of benchmarking measures. PMID:21768320

  14. Should International Classification of Diseases codes be used to survey hospital-acquired pneumonia?

    Science.gov (United States)

    Wolfensberger, A; Meier, A H; Kuster, S P; Mehra, T; Meier, M-T; Sax, H

    2018-05-01

    As surveillance of hospital-acquired pneumonia (HAP) is very resource intensive, alternatives for HAP surveillance are needed urgently. This study compared HAP rates according to routine discharge diagnostic codes of the International Classification of Diseases, 10 th Revision (ICD-10; ICD-HAP) with HAP rates according to the validated surveillance definitions of the Hospitals in Europe Link for Infection Control through Surveillance (HELICS/IPSE; HELICS-HAP) by manual retrospective re-evaluation of patient records. The positive predictive value of ICD-HAP for HELICS-HAP was 0.35, and sensitivity was 0.59. Therefore, the currently available ICD-10-based routine discharge data do not allow reliable identification of patients with HAP. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Association between Kawasaki Disease and Autism: A Population-Based Study in Taiwan

    Directory of Open Access Journals (Sweden)

    Ho-Chang Kuo

    2014-04-01

    Full Text Available Objective: The association between Kawasaki disease and autism has rarely been studied in Asian populations. By using a nationwide Taiwanese population-based claims database, we tested the hypothesis that Kawasaki disease may increase the risk of autism in Taiwan. Materials and Methods: Our study cohort consisted of patients who had received the diagnosis of Kawasaki disease (ICD-9-CM: 446.1 between 1997 and 2005 (N = 563. For a comparison cohort, five age- and gender-matched control patients for every patient in the study cohort were selected using random sampling (N = 2,815. All subjects were tracked for 5 years from the date of cohort entry to identify whether they had developed autism (ICD-9-CM code 299.0 or not. Cox proportional hazard regressions were then performed to evaluate 5-year autism-free survival rates. Results: The main finding of this study was that patients with Kawasaki disease seem to not be at increased risk of developing autism. Of the total patients, four patients developed autism during the 5-year follow-up period, among whom two were Kawasaki disease patients and two were in the comparison cohort. Further, the adjusted hazard ratios (AHR (AHR: 4.81; 95% confidence interval: 0.68–34.35; P = 0.117 did not show any statistical significance between the Kawasaki disease group and the control group during the 5-year follow-up. Conclusion: Our study indicated that patients with Kawasaki disease are not at increased risk of autism.

  16. Comparison of Vital Statistics Definitions of Suicide against a Coroner Reference Standard: A Population-Based Linkage Study.

    Science.gov (United States)

    Gatov, Evgenia; Kurdyak, Paul; Sinyor, Mark; Holder, Laura; Schaffer, Ayal

    2018-03-01

    We sought to determine the utility of health administrative databases for population-based suicide surveillance, as these data are generally more accessible and more integrated with other data sources compared to coroners' records. In this retrospective validation study, we identified all coroner-confirmed suicides between 2003 and 2012 in Ontario residents aged 21 and over and linked this information to Statistics Canada's vital statistics data set. We examined the overlap between the underlying cause of death field and secondary causes of death using ICD-9 and ICD-10 codes for deliberate self-harm (i.e., suicide) and examined the sociodemographic and clinical characteristics of misclassified records. Among 10,153 linked deaths, there was a very high degree of overlap between records coded as deliberate self-harm in the vital statistics data set and coroner-confirmed suicides using both ICD-9 and ICD-10 definitions (96.88% and 96.84% sensitivity, respectively). This alignment steadily increased throughout the study period (from 95.9% to 98.8%). Other vital statistics diagnoses in primary fields included uncategorised signs and symptoms. Vital statistics records that were misclassified did not differ from valid records in terms of sociodemographic characteristics but were more likely to have had an unspecified place of injury on the death certificate ( P statistics and coroner classification of suicide deaths suggests that health administrative data can reliably be used to identify suicide deaths.

  17. Hoarding disorder: a new diagnostic category in ICD-11?

    Directory of Open Access Journals (Sweden)

    Leonardo F. Fontenelle

    2014-01-01

    Full Text Available Despite the long-held view that hoarding is a symptom of both obsessive-compulsive disorder and obsessive-compulsive personality disorder, increased evidence has emerged during the last 20 years suggesting that hoarding represents a distinct form of psychopathology. This study reflects the discussions on the nosological status of hoarding carried out by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. The distinctiveness of hoarding is based on its having core symptoms that differ from those of other disorders, as well as distinctive neurobiological correlates and treatment responses. Furthermore, data showing the clinical utility, global applicability, and appropriateness of the concept of hoarding disorder outside specialty mental health settings suggest that this condition should be included in ICD-11. Finally, given the focus of ICD-11 on primary care and public health, the Working Group suggests that poor insight and severe domestic squalor may be considered as specifiers for hoarding disorder in ICD-11.

  18. 9 CFR 11.3 - Scar rule.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Scar rule. 11.3 Section 11.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL... inflammation, and, other bilateral evidence of abuse indicative of soring including, but not limited to...

  19. Gender trouble: The World Health Organization, the International Statistical Classification of Diseases and Related Health Problems (ICD)-11 and the trans kids.

    Science.gov (United States)

    Winter, Sam

    2017-10-01

    The World Health Organization (WHO) is revising its diagnostic manual, the International Statistical Classification of Diseases and Related Health Problems (ICD). At the time of writing, and based on recommendations from its ICD Working Group on Sexual Disorders and Sexual Health, WHO is proposing a new ICD chapter titled Conditions Related to Sexual Health, and that the gender incongruence diagnoses (replacements for the gender identity disorder diagnoses used in ICD-10) should be placed in that chapter. WHO is proposing that there should be a Gender incongruence of childhood (GIC) diagnosis for children below the age of puberty. This last proposal has come under fire. Trans community groups, as well as many healthcare professionals and others working for transgender health and wellbeing, have criticised the proposal on the grounds that the pathologisation of gender diversity at such a young age is inappropriate, unnecessary, harmful and inconsistent with WHO's approach in regard to other aspects of development in childhood and youth. Counter proposals have been offered that do not pathologise gender diversity and instead make use of Z codes to frame and document any contacts that young gender diverse children may have with health services. The author draws on his involvement in the ICD revision process, both as a member of the aforementioned WHO Working Group and as one of its critics, to put the case against the GIC proposal, and to recommend an alternative approach for ICD in addressing the needs of gender diverse children.

  20. Researching on knowledge architecture of design by analysis based on ASME code

    International Nuclear Information System (INIS)

    Bao Shiyi; Zhou Yu; He Shuyan

    2003-01-01

    The quality of knowledge-based system's knowledge architecture is one of decisive factors of knowledge-based system's validity and rationality. For designing the ASME code knowledge based system, this paper presents a knowledge acquisition method which is extracting knowledge through document analysis consulted domain experts' knowledge. Then the paper describes knowledge architecture of design by analysis based on the related rules in ASME code. The knowledge of the knowledge architecture is divided into two categories: one is empirical knowledge, and another is ASME code knowledge. Applied as the basement of the knowledge architecture, a general procedural process of design by analysis that is met the engineering design requirements and designers' conventional mode is generalized and explained detailed in the paper. For the sake of improving inference efficiency and concurrent computation of KBS, a kind of knowledge Petri net (KPN) model is proposed and adopted in expressing the knowledge architecture. Furthermore, for validating and verifying of the empirical rules, five knowledge validation and verification theorems are given in the paper. Moreover the research production is applicable to design the knowledge architecture of ASME codes or other engineering standards. (author)

  1. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    Science.gov (United States)

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  2. Multilevel Association Rule Mining for Bridge Resource Management Based on Immune Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Yang Ou

    2014-01-01

    Full Text Available This paper is concerned with the problem of multilevel association rule mining for bridge resource management (BRM which is announced by IMO in 2010. The goal of this paper is to mine the association rules among the items of BRM and the vessel accidents. However, due to the indirect data that can be collected, which seems useless for the analysis of the relationship between items of BIM and the accidents, the cross level association rules need to be studied, which builds the relation between the indirect data and items of BRM. In this paper, firstly, a cross level coding scheme for mining the multilevel association rules is proposed. Secondly, we execute the immune genetic algorithm with the coding scheme for analyzing BRM. Thirdly, based on the basic maritime investigation reports, some important association rules of the items of BRM are mined and studied. Finally, according to the results of the analysis, we provide the suggestions for the work of seafarer training, assessment, and management.

  3. Health care resource utilization before and after perampanel initiation among patients with epilepsy in the United States.

    Science.gov (United States)

    Faught, Edward; Laliberté, François; Wang, Zhixiao; Barghout, Victoria; Haider, Batool; Lejeune, Dominique; Germain, Guillaume; Choi, Jiyoon; Wagh, Aneesha; Duh, Mei Sheng

    2017-10-01

    The purpose of this study was to evaluate changes in health care resource utilization following the initiation of perampanel for the treatment of epilepsy in the United States. Health care claims from Symphony Health's Integrated Dataverse database between December 2012 and November 2015 were analyzed. Patients newly initiated on perampanel, having ≥1 epilepsy (International Classification of Diseases, Ninth Revision, Clinical Modification [ICD-9-CM] code 345.xx, ICD-10-CM code G40.xxx) or nonfebrile convulsion (ICD-9-CM code 780.39, ICD-10-CM code R56.9) diagnosis, and having ≥6 months of baseline and observation periods were included. Patients <12 years old at perampanel initiation were excluded. Of the 2,508 perampanel patients included in the study, the mean [median] (±standard deviation [SD]) age was 35.8 [34] (±16.0) years and 56.2% were female. The mean [median] (±SD) observation duration was 459.8 [462] (±146.3) days in the postperampanel period. The postperampanel period was associated with significantly lower rates of all health care resource utilization outcomes than the pre-period. For the post- versus pre-period, perampanel users had 42.3 versus 53.8 overall hospitalizations per 100 person-years (rate ratio [RR] = 0.80, p < 0.001) and 1,240.2 versus 1,343.8 outpatient visits per 100 person-years (RR = 0.91, p < 0.001). Epilepsy-related hospitalizations and outpatient visits were 25.2 versus 33.6 per 100 person-years (RR = 0.76, p < 0.001) and 327.0 versus 389.0 per 100 person-years (RR = 0.84, p < 0.001), respectively. Additionally, a significantly lower rate of status epilepticus in the post-period (1.8 events per 100 person-years) was observed compared to the pre-period (4.4 events per 100 person-years; RR = 0.43, p < 0.001). The monthly time trend of hospitalizations showed an increasing trend leading up to the initiation of perampanel, after which the hospitalizations decreased steadily. Use of perampanel for the treatment of epilepsy was

  4. DSM-IV, DSM-5, and ICD-11: Identifying children with posttraumatic stress disorder after disasters.

    Science.gov (United States)

    Danzi, BreAnne A; La Greca, Annette M

    2016-12-01

    Different criteria for diagnosing posttraumatic stress disorder (PTSD) have been recommended by the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the proposed 11th edition of the International Classification of Diseases (ICD-11). Although children are vulnerable to PTSD following disasters, little is known about whether these revised criteria are appropriate for preadolescents, as diagnostic revisions have been based primarily on adult research. This study investigated rates of PTSD using DSM-IV, DSM-5, and ICD-11 diagnostic criteria, and their associations with symptom severity, impairment, and PTSD risk factors. Children (7-11 years) exposed to Hurricanes Ike (n = 327) or Charley (n = 383) completed measures 8-9 months postdisaster. Using diagnostic algorithms for DSM-IV, DSM-5, and ICD-11, rates of 'probable' PTSD were calculated. Across samples, rates of PTSD were similar. However, there was low agreement across the diagnostic systems, with about a third overlap in identified cases. Children identified only by ICD-11 had higher 'core' symptom severity but lower impairment than children identified only by DSM-IV or DSM-5. ICD-11 was associated with more established risk factors for PTSD than was DSM-5. Findings revealed differences in PTSD diagnosis across major diagnostic systems for preadolescent children, with no clear advantage to any one system. Further research on developmentally sensitive PTSD criteria for preadolescent children is needed. © 2016 Association for Child and Adolescent Mental Health.

  5. Code, standard and specifications

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography also same as the other technique, it need standard. This standard was used widely and method of used it also regular. With that, radiography testing only practical based on regulations as mentioned and documented. These regulation or guideline documented in code, standard and specifications. In Malaysia, level one and basic radiographer can do radiography work based on instruction give by level two or three radiographer. This instruction was produced based on guideline that mention in document. Level two must follow the specifications mentioned in standard when write the instruction. From this scenario, it makes clearly that this radiography work is a type of work that everything must follow the rule. For the code, the radiography follow the code of American Society for Mechanical Engineer (ASME) and the only code that have in Malaysia for this time is rule that published by Atomic Energy Licensing Board (AELB) known as Practical code for radiation Protection in Industrial radiography. With the existence of this code, all the radiography must follow the rule or standard regulated automatically.

  6. Association of Postoperative Readmissions With Surgical Quality Using a Delphi Consensus Process to Identify Relevant Diagnosis Codes.

    Science.gov (United States)

    Mull, Hillary J; Graham, Laura A; Morris, Melanie S; Rosen, Amy K; Richman, Joshua S; Whittle, Jeffery; Burns, Edith; Wagner, Todd H; Copeland, Laurel A; Wahl, Tyler; Jones, Caroline; Hollis, Robert H; Itani, Kamal M F; Hawn, Mary T

    2018-04-18

    Postoperative readmission data are used to measure hospital performance, yet the extent to which these readmissions reflect surgical quality is unknown. To establish expert consensus on whether reasons for postoperative readmission are associated with the quality of surgery in the index admission. In a modified Delphi process, a panel of 14 experts in medical and surgical readmissions comprising physicians and nonphysicians from Veterans Affairs (VA) and private-sector institutions reviewed 30-day postoperative readmissions from fiscal years 2008 through 2014 associated with inpatient surgical procedures performed at a VA medical center between October 1, 2007, and September 30, 2014. The consensus process was conducted from January through May 2017. Reasons for readmission were grouped into categories based on International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes. Panelists were given the proportion of readmissions coded by each reason and median (interquartile range) days to readmission. They answered the question, "Does the readmission reason reflect possible surgical quality of care problems in the index admission?" on a scale of 1 (never related) to 5 (directly related) in 3 rounds of consensus building. The consensus process was completed in May 2017 and data were analyzed in June 2017. Consensus on proportion of ICD-9-coded readmission reasons that reflected quality of surgical procedure. In 3 Delphi rounds, the 14 panelists achieved consensus on 50 reasons for readmission; 12 panelists also completed group telephone calls between rounds 1 and 2. Readmissions with diagnoses of infection, sepsis, pneumonia, hemorrhage/hematoma, anemia, ostomy complications, acute renal failure, fluid/electrolyte disorders, or venous thromboembolism were considered associated with surgical quality and accounted for 25 521 of 39 664 readmissions (64% of readmissions; 7.5% of 340 858 index surgical procedures). The proportion of readmissions

  7. Prevalence of resistance to antibiotics according to International Classification of Diseases (ICD-10) in Boo Ali Sina Hospital of Sari, 2011-2012.

    Science.gov (United States)

    Afshar, Parvaneh; Saravi, Benyamin Mohseni; Nehmati, Ebrahim; Farahabbadi, Ebrahim Bagherian; Yazdanian, Azadeh; Siamian, Hasan; Vahedi, Mohammad

    2013-01-01

    One of the issues in health care delivery system is resistance to antibiotics. Many researches were done to show the causes and antibiotics which was resistance. In most researches the methods of classifying and reporting this resistance were made by researcher, so in this research we examined the International Classification of Diseases 10 the edition (ICD-10). This is a descriptive cross section study; data was collected from laboratory of Boo Ali Sina hospital, during 2011-2012. The check list was designed according the aim of study. Variables were age, bacterial agent, specimen, and antibiotics. The bacteria and resistance were classified with ICD-10. The data were analyzed with SPSS (16) soft ware and the descriptive statistics. Results showed that of the 10198 request for culture and antibiogram, there were 1020(10%) resistance. The specimen were 648 (63.5%) urine, blood 127(12.5%), other secretion 125 (12/3%), sputum 102 (10%), lumbar puncture 8 (0/8%), stool 6 (6/0%) and bone marrow 4 (0.4%). The E coli was the most 413 (40.5%) resistance cause to antibiotics which was coded with B96.2 and the most resistance was to multiple antibiotics 885(86.8%) with the U88 code. The results showed that by using the ICD-10 codes, the study of multiple causes and resistance is possible. The routine usage of coding of the ICD-10 would result to an up to date bank of resistance to antibiotics in every hospitals and useful for physicians, other health care, and health administrations.

  8. Generator replacement is associated with an increased rate of ICD lead alerts.

    Science.gov (United States)

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Statins Decrease Oxidative Stress and ICD Therapies

    Directory of Open Access Journals (Sweden)

    Heather L. Bloom

    2010-01-01

    Full Text Available Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation. Methods. 304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs and interleukin-6 (IL-6. Results. Subjects included 252 (83% men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF 20%. ICD implant duration was 29 ± 27 months. Use of statins correlated with lower ICD events (r=0.12, P=.02. Subjects on statins had lower hsCRP (5.2 versus 6.3; P=.05 and DROM levels (373 versus 397; P=.03. Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor. Conclusion. ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.

  10. RSE-M: In-Service Inspection Rules for Mechanical Components of PWR Nuclear Islands

    International Nuclear Information System (INIS)

    2016-01-01

    The RSE-M code defines in-service inspection operations. It applies to pressure equipment used in PWR plants, as well as spare parts for such equipment. The RSE-M code does not apply to equipment made from materials other than metal. It is based on the RCC-M code for requirements relating to the design and fabrication of mechanical components. Use: The inspection rules specified in the RSE-M code describe the standard requirements of best practice within the French nuclear industry, based on its own feedback from operating several nuclear units and partly supplemented with requirements stipulated by French regulations. To date, the 58 units in France's nuclear infrastructure enforce the in-service inspection rules of the RSE-M code. Operation of 30 commissioned units in China's nuclear infrastructure, corresponding to the M310, CPR-1000 and CPR-600 reactors, is based on the RSE-M code (since 2007, use of AFCEN codes has been required by NNSA for Generation II+ reactors). Contents of the 2016 Edition: Volume I - Rules: Section A - General rules, Section B - Specific rules for class 1 components, Section C - Specific rules for class 2 or 3 components, Section D - Specific rules for components not assigned to any particular RSE-M class; Volume II - Appendices 1 to 8: Appendices 1.0 to 1.9: supporting appendices for the general requirements, Appendix 2.1: appendix associated with chap. 2000 Requalifications, Hydraulic Proof Tests and Hydraulic Tests, Appendices 4.1 to 4.4: appendices associated with chap. 4000 Examination techniques, Appendices 5.1 to 5.8 and RPP2: appendices associated with chap. 5000 Mechanical and Materials, Appendices 8.1 to 8.2: appendices associated with chap. 8000 Maintenance Operations; Volume III: Appendix 3.1 - Visit tables: main primary and secondary systems, EPR pre-service inspection program, Class 2 or 3 vessels; Appendix 3.2 - Inspection Plans For Non-Nuclear Pressure Equipment

  11. THE APPLICATION PROCESS OF HAMBURG RULES, GIVEN THE CONTEXT OF THE EMERGENCE AND ENTRY INTO FORCE OF THE NEW ROMANIAN CIVIL CODE

    Directory of Open Access Journals (Sweden)

    Adriana Elena Belu

    2013-11-01

    Full Text Available The paper aims to conduct a comparative analysis and tries to offer an objective point of view regarding a number of questions arisen in practice, related to the applicability of the 1978 Hamburg Rules and keeping public order of Romanian private international law, such as those that aim at: agreeing upon the applicability of the foreign law by the Romanian parties; applicability of the Hamburg Rules; public nuisance of the Romanian private international law; character of public policy rule of the Hamburg Rules. In the application process of the Hamburg Rules, given the context of the emergence and entry into force of the New Civil Code, obviously, the provisions of the Romanian Civil Code shall apply in addition, where the international convention lacks. Therefore, in order to apply the logic of the provisions of the Civil Code in full compliance with the international standards, though giving priority to the latter rules, a rigorous analysis is required, analysis which becomes more complex given the fact that, in accordance with Art. 230 of Law no. 71/2011 to implement Law no. 287/2009 on the Civil Code, Book II "About Maritime Trade and Sailing" of the Commercial Code, will be abolished upon the entry into force of the Maritime Code, as those provisions remain in force, being applied with priority to the rules of the Civil Code.

  12. Specific and social phobias in ICD-11

    NARCIS (Netherlands)

    Emmelkamp, P.M.G.

    2012-01-01

    The purpose of this article is to discuss the current status of research with respect to specific phobias and social phobia as defined in the ICD-10 and DSM-IV, and to provide op- tions for their classification in the ICD-11. Both ICD-10 and DSM-IV identify three main classes of phobias: specific

  13. Do UK television alcohol advertisements abide by the code of broadcast advertising rules regarding the portrayal of alcohol?

    Science.gov (United States)

    Searle, Rebecca; Alston, Daisy; French, David P

    2014-01-01

    The aim of the study was to assess the extent to which members of the UK general public perceive television alcohol advertisements to comply with the regulatory code governing these: the Advertising Standards Authority Code of Broadcast Advertising (BCAP Code). The Code provides a general principle and 16 rules to prevent such adverts implying, condoning or encouraging immoderate, irresponsible or anti-social drinking. Quota sample of 373 adults, representative of the UK population aged 18-74 years in terms of age and gender, were recruited at a train station. Participants were shown one of seven advertisements that had been broadcast in the previous month on the two leading commercial television channels, and then completed a questionnaire with 40 statements representing the BCAP Code rules. Overall, 75% of the participants rated the advertisements as breaching at least one rule from the BCAP Code. Breaches were observed for all the seven advertisements, ranging from 49 to 91% non-compliant. Rules regarding alcohol being presented as contributing to popularity or confidence, and implying that alcohol is capable of changing mood, physical condition, behaviour, or as nourishment, were seen as being breached by over 50% of participants. A clear majority of the UK general public perceive alcohol advertisements to breach the BCAP Code, suggesting that the current regulatory system for UK television alcohol advertisements is inadequate. © The Author 2014. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  14. Identifying influenza-like illness presentation from unstructured general practice clinical narrative using a text classifier rule-based expert system versus a clinical expert.

    Science.gov (United States)

    MacRae, Jayden; Love, Tom; Baker, Michael G; Dowell, Anthony; Carnachan, Matthew; Stubbe, Maria; McBain, Lynn

    2015-10-06

    We designed and validated a rule-based expert system to identify influenza like illness (ILI) from routinely recorded general practice clinical narrative to aid a larger retrospective research study into the impact of the 2009 influenza pandemic in New Zealand. Rules were assessed using pattern matching heuristics on routine clinical narrative. The system was trained using data from 623 clinical encounters and validated using a clinical expert as a gold standard against a mutually exclusive set of 901 records. We calculated a 98.2 % specificity and 90.2 % sensitivity across an ILI incidence of 12.4 % measured against clinical expert classification. Peak problem list identification of ILI by clinical coding in any month was 9.2 % of all detected ILI presentations. Our system addressed an unusual problem domain for clinical narrative classification; using notational, unstructured, clinician entered information in a community care setting. It performed well compared with other approaches and domains. It has potential applications in real-time surveillance of disease, and in assisted problem list coding for clinicians. Our system identified ILI presentation with sufficient accuracy for use at a population level in the wider research study. The peak coding of 9.2 % illustrated the need for automated coding of unstructured narrative in our study.

  15. Public Health Data in Action: An Analysis of Using Louisiana Vital Statistics for Quality Improvement and Payment Reform.

    Science.gov (United States)

    Danilack, Valery A; Gee, Rebekah E; Berthelot, Danielle P; Gurvich, Rebecca; Muri, Janet H

    2017-05-01

    Introduction In 2012, the Louisiana (LA) Department of Health and Hospitals revised the LA birth certificate to include medical reasons for births before 39 completed weeks' gestation. We compared the completeness and validity of these data with hospital discharge records. Methods For births occurring 4/1/2012-9/30/2012 at Woman's Hospital of Baton Rouge, we linked maternal delivery and newborn birth data collected through the National Perinatal Information Center with LA birth certificates. Among early term births (37-38 completed weeks' gestation), we quantified the reasons for early delivery listed on the birth certificate and compared them with ICD-9-CM codes from Woman's discharge data. Results Among 4353 birth certificates indicating delivery at Woman's Hospital, we matched 99.8% to corresponding Woman's administrative data. Among 1293 early term singleton births, the most common reasons for early delivery listed on the birth certificate were spontaneous active labor (57.5%), gestational hypertensive disorders (15.3%), gestational diabetes (8.7%), and premature rupture of membranes (8.1%). Only 2.7% of births indicated "other reason" as the only reason for early delivery. Most reasons for early delivery had >80% correspondence with ICD-9-CM codes. Lower correspondence (35 and 72%, respectively) was observed for premature rupture of membranes and abnormal heart rate or fetal distress. Discussion There was near-perfect ability to match LA birth certificates with Woman's Hospital records, and the agreement between reasons for early delivery on the birth certificate and ICD-9-CM codes was high. A benchmark of 2.7% can be used as an attainable frequency of "other reason" for early delivery reported by hospitals. Louisiana implemented an effective mechanism to identify and explain early deliveries using vital records.

  16. Experimental data bases useful for quantification of model uncertainties in best estimate codes

    International Nuclear Information System (INIS)

    Wilson, G.E.; Katsma, K.R.; Jacobson, J.L.; Boodry, K.S.

    1988-01-01

    A data base is necessary for assessment of thermal hydraulic codes within the context of the new NRC ECCS Rule. Separate effect tests examine particular phenomena that may be used to develop and/or verify models and constitutive relationships in the code. Integral tests are used to demonstrate the capability of codes to model global characteristics and sequence of events for real or hypothetical transients. The nuclear industry has developed a large experimental data base of fundamental nuclear, thermal-hydraulic phenomena for code validation. Given a particular scenario, and recognizing the scenario's important phenomena, selected information from this data base may be used to demonstrate applicability of a particular code to simulate the scenario and to determine code model uncertainties. LBLOCA experimental data bases useful to this objective are identified in this paper. 2 tabs

  17. 9 CFR 202.101 - Rule 1: Meaning of words.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Rule 1: Meaning of words. 202.101 Section 202.101 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS ADMINISTRATION...: Meaning of words. In these rules, words in the singular form shall be deemed to import the plural, and...

  18. Defining pediatric traumatic brain injury using International Classification of Diseases Version 10 Codes: a systematic review.

    Science.gov (United States)

    Chan, Vincy; Thurairajah, Pravheen; Colantonio, Angela

    2015-02-04

    Although healthcare administrative data are commonly used for traumatic brain injury (TBI) research, there is currently no consensus or consistency on the International Classification of Diseases Version 10 (ICD-10) codes used to define TBI among children and youth internationally. This study systematically reviewed the literature to explore the range of ICD-10 codes that are used to define TBI in this population. The identification of the range of ICD-10 codes to define this population in administrative data is crucial, as it has implications for policy, resource allocation, planning of healthcare services, and prevention strategies. The databases MEDLINE, MEDLINE In-Process, Embase, PsychINFO, CINAHL, SPORTDiscus, and Cochrane Database of Systematic Reviews were systematically searched. Grey literature was searched using Grey Matters and Google. Reference lists of included articles were also searched for relevant studies. Two reviewers independently screened all titles and abstracts using pre-defined inclusion and exclusion criteria. A full text screen was conducted on articles that met the first screen inclusion criteria. All full text articles that met the pre-defined inclusion criteria were included for analysis in this systematic review. A total of 1,326 publications were identified through the predetermined search strategy and 32 articles/reports met all eligibility criteria for inclusion in this review. Five articles specifically examined children and youth aged 19 years or under with TBI. ICD-10 case definitions ranged from the broad injuries to the head codes (ICD-10 S00 to S09) to concussion only (S06.0). There was overwhelming consensus on the inclusion of ICD-10 code S06, intracranial injury, while codes S00 (superficial injury of the head), S03 (dislocation, sprain, and strain of joints and ligaments of head), and S05 (injury of eye and orbit) were only used by articles that examined head injury, none of which specifically examined children and

  19. Medical Surveillance Monthly Report (MSMR). Volume 18, Number 01, January 2011

    Science.gov (United States)

    2011-01-01

    conditions (ICD-9-CM: 287), or malaria complicating pregnancy (ICD-9-CM: 647.4) in any diagnostic position; or (5) a hospitalization record with a...4) a hospitalization record with a non- primary diagnosis of malaria plus a diagnosis of anemia (ICD-9-CM: 280-285), thrombocyctopenia and related ...publication of the Armed Forces Health Surveillance Center Update: Malaria , U.S. Armed Forces, 2010 _______________________________________2 Diagnoses of

  20. Psychotic disorders in DSM-5 and ICD-11.

    Science.gov (United States)

    Biedermann, Falko; Fleischhacker, W Wolfgang

    2016-08-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) was published by the American Psychiatric Association (APA) in 2013, and the Work Group on the Classification of Psychotic disorders (WGPD), installed by the World Health Organization (WHO), is expected to publish the new chapter about schizophrenia and other primary psychotic disorders in 2017. We reviewed the available literature to summarize the major changes, innovations, and developments of both manuals. If available and possible, we outline the theoretical background behind these changes. Due to the fact that the development of ICD-11 has not yet been completed, the details about ICD-11 are still proposals under ongoing revision. In this ongoing process, they may be revised and therefore have to be seen as proposals. DSM-5 has eliminated schizophrenia subtypes and replaced them with a dimensional approach based on symptom assessments. ICD-11 will most likely go in a similar direction, as both manuals are planned to be more harmonized, although some differences will remain in details and the conceptual orientation. Next to these modifications, ICD-11 will provide a transsectional diagnostic criterion for schizoaffective disorders and a reorganization of acute and transient psychotic and delusional disorders. In this manuscript, we will compare the 2 classification systems.

  1. Reliability of cause of death coding: an international comparison.

    Science.gov (United States)

    Antini, Carmen; Rajs, Danuta; Muñoz-Quezada, María Teresa; Mondaca, Boris Andrés Lucero; Heiss, Gerardo

    2015-07-01

    This study evaluates the agreement of nosologic coding of cardiovascular causes of death between a Chilean coder and one in the United States, in a stratified random sample of death certificates of persons aged ≥ 60, issued in 2008 in the Valparaíso and Metropolitan regions, Chile. All causes of death were converted to ICD-10 codes in parallel by both coders. Concordance was analyzed with inter-coder agreement and Cohen's kappa coefficient by level of specification ICD-10 code for the underlying cause and the total causes of death coding. Inter-coder agreement was 76.4% for all causes of death and 80.6% for the underlying cause (agreement at the four-digit level), with differences by the level of specification of the ICD-10 code, by line of the death certificate, and by number of causes of death per certificate. Cohen's kappa coefficient was 0.76 (95%CI: 0.68-0.84) for the underlying cause and 0.75 (95%CI: 0.74-0.77) for the total causes of death. In conclusion, causes of death coding and inter-coder agreement for cardiovascular diseases in two regions of Chile are comparable to an external benchmark and with reports from other countries.

  2. Greater Prevalence of Proposed ICD-11 Alcohol and Cannabis Dependence Compared to ICD-10, DSM-IV, and DSM-5 in Treated Adolescents.

    Science.gov (United States)

    Chung, Tammy; Cornelius, Jack; Clark, Duncan; Martin, Christopher

    2017-09-01

    Proposed International Classification of Diseases, 11th edition (ICD-11), criteria for substance use disorder (SUD) radically simplify the algorithm used to diagnose substance dependence. Major differences in case identification across DSM and ICD impact determinations of treatment need and conceptualizations of substance dependence. This study compared the draft algorithm for ICD-11 SUD against DSM-IV, DSM-5, and ICD-10, for alcohol and cannabis. Adolescents (n = 339, ages 14 to 18) admitted to intensive outpatient addictions treatment completed, as part of a research study, a Structured Clinical Interview for DSM SUDs adapted for use with adolescents and which has been used to assess DSM and ICD SUD diagnoses. Analyses examined prevalence across classification systems, diagnostic concordance, and sources of diagnostic disagreement. Prevalence of any past-year proposed ICD-11 alcohol or cannabis use disorder was significantly lower compared to DSM-IV and DSM-5 (ps DSM-5, and ICD-10 (ps DSM-5 SUD diagnoses showed only moderate concordance. For both alcohol and cannabis, youth typically met criteria for an ICD-11 dependence diagnosis by reporting tolerance and much time spent using or recovering from the substance, rather than symptoms indicating impaired control over use. The proposed ICD-11 dependence algorithm appears to "overdiagnose" dependence on alcohol and cannabis relative to DSM-IV and ICD-10 dependence, and DSM-5 moderate/severe use disorder, generating potential "false-positive" cases of dependence. Among youth who met criteria for proposed ICD-11 dependence, few reported impaired control over substance use, highlighting ongoing issues in the conceptualization and diagnosis of SUD. Copyright © 2017 by the Research Society on Alcoholism.

  3. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  4. Knowledge rule base for the beam optics program TRACE 3-D

    International Nuclear Information System (INIS)

    Gillespie, G.H.; Van Staagen, P.K.; Hill, B.W.

    1993-01-01

    An expert system type of knowledge rule base has been developed for the input parameters used by the particle beam transport program TRACE 3-D. The goal has been to provide the program's user with adequate on-screen information to allow him to initially set up a problem with minimal open-quotes off-lineclose quotes calculations. The focus of this work has been in developing rules for the parameters which define the beam line transport elements. Ten global parameters, the particle mass and charge, beam energy, etc., are used to provide open-quotes expertclose quotes estimates of lower and upper limits for each of the transport element parameters. For example, the limits for the field strength of the quadrupole element are based on a water-cooled, iron-core electromagnet with dimensions derived from practical engineering constraints, and the upper limit for the effective length is scaled with the particle momenta so that initially parallel trajectories do not cross the axis inside the magnet. Limits for the quadrupole doublet and triplet parameters incorporate these rules and additional rules based on stable FODO lattices and bidirectional focusing requirements. The structure of the rule base is outlined and examples for the quadrupole singlet, doublet and triplet are described. The rule base has been implemented within the Shell for Particle Accelerator Related Codes (SPARC) graphical user interface (GUI)

  5. Buckling rules in design codes: state of the art and future developments

    Energy Technology Data Exchange (ETDEWEB)

    Turbat, A. [FRAMATOME ANP, 69 - Lyon (France); Meziere, Y. [Electricite de France (EDF SEPTEN), 69 - Villeurbanne (France)

    2001-07-01

    Buckling, which can affect structures like bars, beams and shells when they are submitted to compressive stresses, can lead to unacceptable deformations and ruptures. Consequently, main Design Codes, especially those used in nuclear industry, include rules and analysis methods in order to prevent this phenomenon. In this paper, a review of buckling rules and/or analysis methods existing in ASME, RCC-M, RCC-MR and European Recommendations is performed. Then, these rules and methods are applied to the case of a cylinder filled with water and submitted to a seismic loading and results are compared. In the last part, current developments of methods to analyse creep buckling and dynamic buckling which should come and complete RCC-MR soon are presented. (author)

  6. Buckling rules in design codes: state of the art and future developments

    International Nuclear Information System (INIS)

    Turbat, A.; Meziere, Y.

    2001-01-01

    Buckling, which can affect structures like bars, beams and shells when they are submitted to compressive stresses, can lead to unacceptable deformations and ruptures. Consequently, main Design Codes, especially those used in nuclear industry, include rules and analysis methods in order to prevent this phenomenon. In this paper, a review of buckling rules and/or analysis methods existing in ASME, RCC-M, RCC-MR and European Recommendations is performed. Then, these rules and methods are applied to the case of a cylinder filled with water and submitted to a seismic loading and results are compared. In the last part, current developments of methods to analyse creep buckling and dynamic buckling which should come and complete RCC-MR soon are presented. (author)

  7. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    DEFF Research Database (Denmark)

    Habibovic, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2014-01-01

    AIMS: Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed 10...... with a two-factor model involving both negative (α = 0.84) and positive expectations (α = 0.77) with a score range of 0-20 for each factor. Negative treatment expectations were associated with higher levels of anxiety (β = 0.443; P ...-item EXPECtations Towards ICD therapy (EXPECT-ICD) in relation to anxiety, depression, and ICD related concerns 3 months post-implant.METHODS AND RESULTS: Consecutive implanted ICD patients were included as part of the WEB-based distress management programme for ICD patients (WEBCARE) trial from six...

  8. Application of the ASME code in the design of the GA-4 and GA-9 casks

    International Nuclear Information System (INIS)

    Mings, W.J.; Koploy, M.A.

    1992-01-01

    General Atomics (GA) is developing two spent fuel shipping casks for transport by legal weight truck (LWT). The casks are designed to the loading, environmental conditions and safety requirements defined in Title 10 of the Code of Federal Regulations, Part 71 (10CFR71). To ensure that all components of the cask meet the 10CFR71 rules, GA established structural design criteria for each component based on NRC Regulatory Guides and the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code). This paper discusses the criteria used for different cask components, how they were applied and the conservatism and safety margins built into the criteria and assumption

  9. Ontario emissions trading code : emission reduction credit creation, recording and transfer rules, rules for renewable energy projects and conservation projects, and rules for the operation of the Ontario Emissions Trading Registry

    International Nuclear Information System (INIS)

    2001-12-01

    Emissions trading has been an integral part of Ontario's air quality strategy since December 31, 2001. Ontario has adopted the 'cap, credit and trade' type of emissions trading system, a hybrid that takes the best features of pure 'cap-and-trade' and 'baseline-and-credit' type systems. It covers nitric oxide and sulphur dioxide. The Ontario Emissions Trading Code supplements Ontario Regulation 397/01 and sets out rules for renewable energy projects and conservation projects for which applications for emission allowances can be made. This Code describes the rules for the creation and transfer of emission reduction credits (ERCs). It also explains the rules for the operation of the registry that has been established to provide information to the public about the emissions trading program and records decisions about credit creation and credit and allowance retirement. 3 tabs

  10. Otitis Media and Related Complications among Children with Autism Spectrum Disorders

    Science.gov (United States)

    Adams, Daniel J.; Susi, Apryl; Erdie-Lalena, Christine R.; Gorman, Gregory; Hisle-Gorman, Elizabeth; Rajnik, Michael; Elrod, Marilisa; Nylund, Cade M.

    2016-01-01

    Acute otitis media (AOM) symptoms can be masked by communication deficits, common to children with autism spectrum disorders (ASD). We sought to evaluate the association between ASD and otitis media. Using ICD-9-CM diagnostic codes, we performed a retrospective case-cohort study comparing AOM, and otitis-related diagnoses among children with and…

  11. Medical Surveillance Monthly Report. Volume 19, Number 5

    Science.gov (United States)

    2012-05-01

    Intervertebral disc disorders DDD-related ICD-9-CM codes 723.0 Spinal stenosis , cervical 724.00, 724.01, 724.02, 724.09 Spinal stenosis ,other 723.1...4,6,7 Tick vectors of Rocky Mountain Spotted Fever (RMSF) and other diseases Dermacentor variabilis, the American dog tick or wood tick, is found in

  12. Positive Predictive Values of International Classification of Diseases, 10th Revision Coding Algorithms to Identify Patients With Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Vinusha Kalatharan

    2016-12-01

    Full Text Available Background: International Classification of Diseases, 10th Revision codes (ICD-10 for autosomal dominant polycystic kidney disease (ADPKD is used within several administrative health care databases. It is unknown whether these codes identify patients who meet strict clinical criteria for ADPKD. Objective: The objective of this study is (1 to determine whether different ICD-10 coding algorithms identify adult patients who meet strict clinical criteria for ADPKD as assessed through medical chart review and (2 to assess the number of patients identified with different ADPKD coding algorithms in Ontario. Design: Validation study of health care database codes, and prevalence. Setting: Ontario, Canada. Patients: For the chart review, 201 adult patients with hospital encounters between April 1, 2002, and March 31, 2014, assigned either ICD-10 codes Q61.2 or Q61.3. Measurements: This study measured positive predictive value of the ICD-10 coding algorithms and the number of Ontarians identified with different coding algorithms. Methods: We manually reviewed a random sample of medical charts in London, Ontario, Canada, and determined whether or not ADPKD was present according to strict clinical criteria. Results: The presence of either ICD-10 code Q61.2 or Q61.3 in a hospital encounter had a positive predictive value of 85% (95% confidence interval [CI], 79%-89% and identified 2981 Ontarians (0.02% of the Ontario adult population. The presence of ICD-10 code Q61.2 in a hospital encounter had a positive predictive value of 97% (95% CI, 86%-100% and identified 394 adults in Ontario (0.003% of the Ontario adult population. Limitations: (1 We could not calculate other measures of validity; (2 the coding algorithms do not identify patients without hospital encounters; and (3 coding practices may differ between hospitals. Conclusions: Most patients with ICD-10 code Q61.2 or Q61.3 assigned during their hospital encounters have ADPKD according to the clinical

  13. Asthma and myocardial infarction inpatient hospitalization and emergency room visit counts and rates by county, year and month of admission, age group, race/ethnicity and gender of California residents, 2000-2009.

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of asthma (ICD9-CM 493.0-493.9) and myocardial infarction (ICD9-CM 410) inpatient hospitalizations...

  14. Effect of Cardiac Rehabilitation in Patients with ICD

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2015-01-01

    (rehabilitation: 47.7 points [SD 10.1] vs 54.8 points [7.1] and usual care: 48.1 points [SD 10.9] vs 51.9 points [SD 9.6], P = 0.05). CONCLUSIONS: After ICD implantation, significant gender differences were found in physical health, mental health, and QoL. Effects of rehabilitation were found among men only...... in physical component scale, mental component scale, social functioning, physical functioning, bodily pain, vitality, mental health, and QoL with men having higher scores. Among men only, significant differences were found in VO2 (rehabilitation: 20.9 mL/min/kg [standard deviation (SD) 8.1] vs 23.4 m...... and gender predicted effect of rehabilitation on the mental component scale....

  15. Impulse control disorders and related behaviours (ICD-RBs) in Parkinson's disease patients: Assessment using "Questionnaire for impulsive-compulsive disorders in Parkinson's disease" (QUIP).

    Science.gov (United States)

    Sharma, Ashish; Goyal, Vinay; Behari, Madhuri; Srivastva, Achal; Shukla, Garima; Vibha, Deepti

    2015-01-01

    There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs) in Indian patients with Parkinson's Disease (PD). In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated "Questionnaire for Impulsive-Compulsive Disorders in Parkinson's disease (QUIP)" and to examine their association with Dopamine replacement therapy (DRT). This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver) were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%), at least one Impulse control disorder (ICD) was present in 74 (24.75%) and at least one Impulse control related compulsive behaviour (ICRB) was present in 93 (31.1%) patients. Punding was the most frequent (12.4%) followed by hyper sexuality (11.04%), compulsive hobbyism (9.4%), compulsive shopping (8.4%), compulsive medication use (7.7%), compulsive eating (5.35%), walkabout (4%) and pathological gambling (3.3%). ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD) were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Our study revealed a relatively higher frequency of ICD-RBs, probably because of the use of screening instrument and because

  16. Code of Ethics for Electrical Engineers

    Science.gov (United States)

    Matsuki, Junya

    The Institute of Electrical Engineers of Japan (IEEJ) has established the rules of practice for its members recently, based on its code of ethics enacted in 1998. In this paper, first, the characteristics of the IEEJ 1998 ethical code are explained in detail compared to the other ethical codes for other fields of engineering. Secondly, the contents which shall be included in the modern code of ethics for electrical engineers are discussed. Thirdly, the newly-established rules of practice and the modified code of ethics are presented. Finally, results of questionnaires on the new ethical code and rules which were answered on May 23, 2007, by 51 electrical and electronic students of the University of Fukui are shown.

  17. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-11-01

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  18. Herpes Zoster and Dementia: A Nationwide Population-Based Cohort Study.

    Science.gov (United States)

    Chen, Vincent Chin-Hung; Wu, Shu-I; Huang, Kuo-You; Yang, Yao-Hsu; Kuo, Ting-Yu; Liang, Hsin-Yi; Huang, Kuan-Lun; Gossop, Michael

    Some infectious diseases have been found to be associated with cognitive impairment and dementia. However, the relationship between herpes zoster and dementia has received little attention. This study aimed to investigate this association as well as associations of antiviral treatments for herpes zoster and incident dementia using a large national sample. Cases were identified from the Taiwan National Health Insurance Research Database with a new diagnosis of herpes zoster (ICD-9-CM code: 053) between 1997 and 2013. Each identified individual with a case of herpes zoster was compared with 1 sex-, age-, and residence-matched control subject. Both groups were followed until the first diagnosis of dementia (ICD-9-CM codes: 290.0 to 290.4, 294.1, 331.0 to 331.2, and 331.82), withdrawal from the registry, or the end of 2013. Cox regression analyses and competing risk model were applied, adjusting for sex, age, residence, depression, autoimmune disease, ischemic stroke, traumatic brain injury, alcohol use disorder, and antiviral treatments for herpes zoster to evaluate the risk of interest. A total of 39,205 cases with herpes zoster were identified. Of the 78,410 study and comparison subjects, 4,204 were diagnosed as having dementia during a mean (SD) follow-up period of 6.22 (4.05) years. Herpes zoster was associated with a slightly increased risk of dementia in the fully adjusted model (hazard ratio [HR] = 1.11; 95% CI, 1.04-1.17). Prescriptions of antiviral therapy were associated with a reduced risk of developing dementia following the diagnosis of herpes zoster (HR = 0.55; 95% CI, 0.40-0.77). Herpes zoster was associated with an increased risk of dementia, independent of potential confounding factors. Antiviral treatment might be protective in preventing dementia in patients with herpes zoster. © Copyright 2017 Physicians Postgraduate Press, Inc.

  19. The WHO application of ICD-10 to deaths during the perinatal period (ICD-PM) : results from pilot database testing in South Africa and United Kingdom

    NARCIS (Netherlands)

    Allanson, E. R.; Tuncalp, Oe; Gardosi, J.; Pattinson, R. C.; Francis, A.; Vogel, J. P.; Erwich, J. J. H. M.; Flenady, V. J.; Froen, J. F.; Neilson, J.; Quach, A.; Chou, D.; Mathai, M.; Say, L.; Guelmezoglu, A. M.

    2016-01-01

    Objective To apply the World Health Organization (WHO) Application of the International Classification of Diseases, tenth revision (ICD-10) to deaths during the perinatal period: ICD-Perinatal Mortality (ICD-PM) to existing perinatal death databases. Design Retrospective application of ICD-PM.

  20. ANTINOMIES BETWEEN CIVIL CODE AND NEW CIVIL PROCEDURE CODE: ANALYSIS OF ARTICLE 221 OF THE CC/2002 AND ARTICLE 784 OF THE RULE 13.105/2015

    Directory of Open Access Journals (Sweden)

    Andrea Cristina Zanetti

    2016-06-01

    Full Text Available Article 221 of the Brazilian Civil Code defines the form of evidence to provethe obligations between contracting parties, asserting that just the existence of contract signed by the parties, which are in the free disposal of theirs property, it´s enough to be proven the obligatory relationship between them, independent the adjusted value of the obligation. As noted, the Brazilian Civil Code of 2002 no longer requires that the contracts need to be signed by two witnesses to attest their existence and binding force between the parties. However, Article 784, item III, of Rule n. 13.105/15 (new Civil Procedure Code which will come into force in March 2016, makes it clear that it will only be considered extrajudicial title of the executionaction the particular document signed by the debtor and two (2 witnesses, keeping the expression of Art.585, item II of the CPC/1973. In this sense, one can say that art. 784 of Rule No. 13.105/15 would be contradicting the terms of Art. 221 of the Civil Code/2002? After all,the new Civil Procedure Code requires the presence of two witnesses in private documents (contracts in general. We would be facing an antinomy? This academic paperanalyzesthese issues, contributing to the study of antinomy between the rules of Civil Code and the new Civil Procedure Code, without conclude all the questions related a potential antinomies between these two legislations. These are issues that need tobe carefullyreviewedby the jurist, in searches, for the future solutions.

  1. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas

    2005-01-01

    Concern has been expressed as to the reliability of clinical ICD-10 diagnosis of schizophrenia. This study was designed to assess the diagnostic reliability of the clinical ICD-10 diagnosis of schizophrenia in a random sample of Danish in- and outpatients with a history of psychosis. A sample...... value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...... was seen between OPCRIT-derived ICD-10 and DSM-IV diagnoses (kappa=0.87). Thus, this study demonstrates high reliability of the clinical diagnosis of schizophrenia and even more so of the diagnosis of schizophrenia-spectrum disorder....

  2. Lower urinary tract dysfunction in male Iraq and Afghanistan war veterans: association with mental health disorders: a population-based cohort study.

    Science.gov (United States)

    Breyer, Benjamin N; Cohen, Beth E; Bertenthal, Daniel; Rosen, Raymond C; Neylan, Thomas C; Seal, Karen H

    2014-02-01

    To determine the prevalence and correlates of lower urinary tract symptoms (LUTS) among returned Iraq and Afghanistan veterans; in particular its association with mental health diagnoses and medication use. We performed a retrospective cohort study of Iraq and Afghanistan veterans who were new users of U.S. Department of Veterans Affairs health care. Mental health diagnoses were defined by International Classification of Disease, 9th Revision, Clinical Modification (ICD-9-CM) codes from medical records. LUTS was defined by ICD-9-CM code, use of prescription medication for LUTS, or procedure for LUTS. We determined the independent association of mental health diagnoses and LUTS after adjusting for sociodemographic and military service characteristics, comorbidities, and medications. Of 519,189 veterans, 88% were men and the mean age was 31.8 years (standard deviation ± 9.3). The overall prevalence of LUTS was 2.2% (11,237/519,189). Veterans with post-traumatic stress disorder (PTSD) were significantly more likely to have a LUTS diagnosis, prescription, or related procedure (3.5%) compared with veterans with no mental health diagnoses (1.3%) or a mental health diagnosis other than PTSD (3.1%, P <.001). In adjusted models, LUTS was significantly more common in veterans with PTSD with and without other mental health disorders vs those without mental health disorders (adjusted relative risk [ARR] = 2.04, 95% confidence interval [CI] = 1.94-2.15) and in veterans prescribed opioids (ARR = 2.46, 95% CI = 2.36-2.56). In this study of young returned veterans, mental health diagnoses and prescription for opioids were independently associated with increased risk of receiving a diagnosis, treatment, or procedure for LUTS. Provider awareness may improve the detection and treatment of LUTS, and improve patient care and quality of life. Copyright © 2014. Published by Elsevier Inc.

  3. Evaluation on applicability of the rules, regulations, and industrial codes and standards for SMART development

    International Nuclear Information System (INIS)

    Choi, Suhn; Lee, C C.; Lee, C.K.; Kim, K.K.; Kim, J.P.; Kim, J.H.; Cho, B.H.; Kang, D J.; Bae, G.H.; Chung, M.; Chang, M.H.

    1999-03-01

    In this report, evaluation on applicability of the rules, regulations, and industrial codes and standards for SMART has been made. As the first step, past-to-present status of licensing structures were reviewed. Then, the rules, regulations, and standards applied to YGN 3-6 were listed and reviewed. Finally, evaluation on applicability of such rules and standards for SMART are made in each design fields. During this step technical evaluations on each items of rules, regulations and standards are made and the possible remedies or comments are suggested. The results are summarized in a tabular form and enclosed as Appendix. (Author). 8 refs., 5 tabs., 3 figs

  4. Techniques and implementation of the embedded rule-based expert system using Ada

    Science.gov (United States)

    Liberman, Eugene M.; Jones, Robert E.

    1991-01-01

    Ada is becoming an increasingly popular programming language for large Government-funded software projects. Ada with its portability, transportability, and maintainability lends itself well to today's complex programming environment. In addition, expert systems have also assured a growing role in providing human-like reasoning capability and expertise for computer systems. The integration of expert system technology with Ada programming language, specifically a rule-based expert system using an ART-Ada (Automated Reasoning Tool for Ada) system shell is discussed. The NASA Lewis Research Center was chosen as a beta test site for ART-Ada. The test was conducted by implementing the existing Autonomous Power EXpert System (APEX), a Lisp-base power expert system, in ART-Ada. Three components, the rule-based expert system, a graphics user interface, and communications software make up SMART-Ada (Systems fault Management with ART-Ada). The main objective, to conduct a beta test on the ART-Ada rule-based expert system shell, was achieved. The system is operational. New Ada tools will assist in future successful projects. ART-Ada is one such tool and is a viable alternative to the straight Ada code when an application requires a rule-based or knowledge-based approach.

  5. Rule-Based Event Processing and Reaction Rules

    Science.gov (United States)

    Paschke, Adrian; Kozlenkov, Alexander

    Reaction rules and event processing technologies play a key role in making business and IT / Internet infrastructures more agile and active. While event processing is concerned with detecting events from large event clouds or streams in almost real-time, reaction rules are concerned with the invocation of actions in response to events and actionable situations. They state the conditions under which actions must be taken. In the last decades various reaction rule and event processing approaches have been developed, which for the most part have been advanced separately. In this paper we survey reaction rule approaches and rule-based event processing systems and languages.

  6. Substance use and addictive disorders in DSM-5 and ICD 10 and the draft ICD 11.

    Science.gov (United States)

    Saunders, John B

    2017-07-01

    The present review compares and contrasts the diagnostic entities and taxonomy of substance use and addictive disorders in the beta draft of the Eleventh Revision of the International Classification of Diseases (ICD 11), which was released in November 2016, and the Fifth Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), which was published in mid-2013. Recently published papers relevant to these two classification systems are examined. New initiatives in diagnosis and assessment including the addictions neuroclinical assessment are noted. The draft ICD 11 retains substance dependence as the 'master diagnosis' in contrast to the broader and heterogeneous concept of substance use disorder in DSM-5 and there is empirical support for the coherence of substance dependence for alcohol, cannabis, and prescribed opioids. Both systems now include gambling disorder in the addictive disorders section, with it being transferred from the impulse control disorders section. The new diagnosis of Internet gaming disorder is included in DSM-5 as a condition for further study, and gaming disorder is grouped with the substance and gambling disorders in the draft ICD 11. Initiatives from the U.S. National Institutes of Health (NIH) are highlighting the importance of capturing the neurobiological phases of the addictive cycle in clinical diagnosis and assessment. Although most of the changes in the draft ICD 11 and DSM-5 are incremental, the contrast between DSM-5 substance use disorder and substance dependence in the draft ICD 11, and the inclusion of gambling disorder and gaming disorder will generate much discussion and research.

  7. 25 CFR 18.301 - May a tribe create and adopt a single heir rule without adopting a tribal probate code?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false May a tribe create and adopt a single heir rule without adopting a tribal probate code? 18.301 Section 18.301 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR PROBATE TRIBAL PROBATE CODES Approval of Single Heir Rule § 18.301 May a tribe create and adopt a...

  8. Impact of providing in-home water service on the rates of infectious diseases: results from four communities in Western Alaska.

    Science.gov (United States)

    Thomas, T K; Ritter, T; Bruden, D; Bruce, M; Byrd, K; Goldberger, R; Dobson, J; Hickel, K; Smith, J; Hennessy, T

    2016-02-01

    Approximately 20% of rural Alaskan homes lack in-home piped water; residents haul water to their homes. The limited quantity of water impacts the ability to meet basic hygiene needs. We assessed rates of infections impacted by water quality (waterborne, e.g. gastrointestinal infections) and quantity (water-washed, e.g. skin and respiratory infections) in communities transitioning to in-home piped water. Residents of four communities consented to a review of medical records 3 years before and after their community received piped water. We selected health encounters with ICD-9CM codes for respiratory, skin and gastrointestinal infections. We calculated annual illness episodes for each infection category after adjusting for age. We obtained 5,477 person-years of observation from 1032 individuals. There were 9,840 illness episodes with at least one ICD-9CM code of interest; 8,155 (83%) respiratory, 1,666 (17%) skin, 241 (2%) gastrointestinal. Water use increased from an average 1.5 gallons/capita/day (g/c/d) to 25.7 g/c/d. There were significant (P-value water. This study reinforces the importance of adequate quantities of water for health.

  9. Exploration of SWRL Rule Bases through Visualization, Paraphrasing, and Categorization of Rules

    Science.gov (United States)

    Hassanpour, Saeed; O'Connor, Martin J.; Das, Amar K.

    Rule bases are increasingly being used as repositories of knowledge content on the Semantic Web. As the size and complexity of these rule bases increases, developers and end users need methods of rule abstraction to facilitate rule management. In this paper, we describe a rule abstraction method for Semantic Web Rule Language (SWRL) rules that is based on lexical analysis and a set of heuristics. Our method results in a tree data structure that we exploit in creating techniques to visualize, paraphrase, and categorize SWRL rules. We evaluate our approach by applying it to several biomedical ontologies that contain SWRL rules, and show how the results reveal rule patterns within the rule base. We have implemented our method as a plug-in tool for Protégé-OWL, the most widely used ontology modeling software for the Semantic Web. Our tool can allow users to rapidly explore content and patterns in SWRL rule bases, enabling their acquisition and management.

  10. Gender Incongruence of Childhood: Clinical Utility and Stakeholder Agreement with the World Health Organization's Proposed ICD-11 Criteria.

    Directory of Open Access Journals (Sweden)

    Titia F Beek

    Full Text Available The World Health Organization (WHO is revising the tenth version of the International Classification of Diseases and Related Health Problems (ICD-10. This includes a reconceptualization of the definition and positioning of Gender Incongruence of Childhood (GIC. This study aimed to: 1 collect the views of transgender individuals and professionals regarding the retention of the diagnosis; 2 see if the proposed GIC criteria were acceptable to transgender individuals and health care providers; 3 compare results between two countries with two different healthcare systems to see if these differences influence opinions regarding the GIC diagnosis; and 4 determine whether healthcare providers from high-income countries feel that the proposed criteria are clinically useful and easy to use. A total of 628 participants were included in the study: 284 from the Netherlands (NL; 45.2%, 8 from Flanders (Belgium; 1.3%, and 336 (53.5% from the United Kingdom (UK. Most participants were transgender people (or their partners/relatives; TG (n = 522, 89 participants were healthcare providers (HCPs and 17 were both HCP and TG individuals. Participants completed an online survey developed for this study. Overall, the majority response from transgender participants (42.9% was that if the diagnosis would be removed from the mental health chapter it should also be removed from the ICD-11 completely, while 33.6% thought it should remain in the ICD-11. Participants were generally satisfied with other aspects of the proposed ICD-11 GIC diagnosis: most TG participants (58.4% thought the term Gender Identity Disorder should change, and most thought Gender Incongruence was an improvement (63.0%. Furthermore, most participants (76.1% did not consider GIC to be a psychiatric disorder and placement in a separate chapter dealing with Gender and Sexual Health (the majority response in the NL and selected by 37.5% of the TG participants overall or as a Z-code (the majority response

  11. 46 CFR 280.9 - Special rules for last year of ODS agreement.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Special rules for last year of ODS agreement. 280.9... LINER OPERATORS § 280.9 Special rules for last year of ODS agreement. (a) Reduction in payment of ODS. ODS payable during the last year of any ODS agreement shall be reduced, as provided in paragraph (b...

  12. Health-Care Utilization and Complications of Endoscopic Esophageal Dilation in a National Population

    OpenAIRE

    Goyal, Abhinav; Chatterjee, Kshitij; Yadlapati, Sujani; Singh, Shailender

    2017-01-01

    Background/Aims Esophageal stricture is usually managed with outpatient endoscopic dilation. However, patients with food impaction or failure to thrive undergo inpatient dilation. Esophageal perforation is the most feared complication, and its risk in inpatient setting is unknown. Methods We used National Inpatient Sample (NIS) database for 2007?2013. International Classification of Diseases, 9th revision, Clinical Modification (ICD-9-CM) codes were used to identify patients with esophageal s...

  13. Health-Care Utilization and Complications of Endoscopic Esophageal Dilation in a National Population

    OpenAIRE

    Abhinav Goyal; Kshitij Chatterjee; Sujani Yadlapati; Shailender Singh

    2017-01-01

    Background/Aims Esophageal stricture is usually managed with outpatient endoscopic dilation. However, patients with food impaction or failure to thrive undergo inpatient dilation. Esophageal perforation is the most feared complication, and its risk in inpatient setting is unknown. Methods We used National Inpatient Sample (NIS) database for 2007–2013. International Classification of Diseases, 9th revision, Clinical Modification (ICD-9-CM) codes were used to identify patients with esophageal s...

  14. Obsessive compulsive and related disorders: comparing DSM-5 and ICD-11.

    Science.gov (United States)

    Marras, Anna; Fineberg, Naomi; Pallanti, Stefano

    2016-08-01

    Obsessive-compulsive disorder (OCD) has been recognized as mainly characterized by compulsivity rather than anxiety and, therefore, was removed from the anxiety disorders chapter and given its own in both the American Psychiatric Association (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the Beta Draft Version of the 11th revision of the World Health Organization (WHO) International Classification of Diseases (ICD-11). This revised clustering is based on increasing evidence of common affected neurocircuits between disorders, differently from previous classification systems based on interrater agreement. In this article, we focus on the classification of obsessive-compulsive and related disorders (OCRDs), examining the differences in approach adopted by these 2 nosological systems, with particular attention to the proposed changes in the forthcoming ICD-11. At this stage, notable differences in the ICD classification are emerging from the previous revision, apparently converging toward a reformulation of OCRDs that is closer to the DSM-5.

  15. Dollars and sense: Mitigating budget risk for ICD-10.

    Science.gov (United States)

    Newell, Lucy Mancini; DeSilva, Joseph J

    2013-02-01

    The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.

  16. COPE-ICD: Patient experience of participation in an ICD specific rehabilitation programme

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Birthe Dagmar; Svendsen, Jesper Hastrup

    2012-01-01

    individualized care. Four themes emerged: Knowledge: patients gained much needed understanding; Physical attention: patients interpreted body signals and adjusted their exercise behaviour; Trust: patients regained trust, felt secure and dared to live again; Strategies of living: patients' coping was supported...... through reflection and professional dialogue, and they dealt with the risk of shock or death. CONCLUSION: Participating in an ICD-specific rehabilitation programme can make patients feel inspired and secure through individualized care. They discover that they have to rethink some of their strategies......PURPOSE: Evaluating rehabilitation programmes from the patient's perspective is much needed, as the patients are the most important stakeholders in the health care system. A comprehensive rehabilitation programme, COPE-ICD programme, consists of exercise training and nursing consultations during...

  17. Identifying Homelessness among Veterans Using VA Administrative Data: Opportunities to Expand Detection Criteria.

    Directory of Open Access Journals (Sweden)

    Rachel Peterson

    Full Text Available Researchers at the U.S. Department of Veterans Affairs (VA have used administrative criteria to identify homelessness among U.S. Veterans. Our objective was to explore the use of these codes in VA health care facilities. We examined VA health records (2002-2012 of Veterans recently separated from the military and identified as homeless using VA conventional identification criteria (ICD-9-CM code V60.0, VA specific codes for homeless services, plus closely allied V60 codes indicating housing instability. Logistic regression analyses examined differences between Veterans who received these codes. Health care services and co-morbidities were analyzed in the 90 days post-identification of homelessness. VA conventional criteria identified 21,021 homeless Veterans from Operations Enduring Freedom, Iraqi Freedom, and New Dawn (rate 2.5%. Adding allied V60 codes increased that to 31,260 (rate 3.3%. While certain demographic differences were noted, Veterans identified as homeless using conventional or allied codes were similar with regards to utilization of homeless, mental health, and substance abuse services, as well as co-morbidities. Differences were noted in the pattern of usage of homelessness-related diagnostic codes in VA facilities nation-wide. Creating an official VA case definition for homelessness, which would include additional ICD-9-CM and other administrative codes for VA homeless services, would likely allow improved identification of homeless and at-risk Veterans. This also presents an opportunity for encouraging uniformity in applying these codes in VA facilities nationwide as well as in other large health care organizations.

  18. Identifying Homelessness among Veterans Using VA Administrative Data: Opportunities to Expand Detection Criteria

    Science.gov (United States)

    Peterson, Rachel; Gundlapalli, Adi V.; Metraux, Stephen; Carter, Marjorie E.; Palmer, Miland; Redd, Andrew; Samore, Matthew H.; Fargo, Jamison D.

    2015-01-01

    Researchers at the U.S. Department of Veterans Affairs (VA) have used administrative criteria to identify homelessness among U.S. Veterans. Our objective was to explore the use of these codes in VA health care facilities. We examined VA health records (2002-2012) of Veterans recently separated from the military and identified as homeless using VA conventional identification criteria (ICD-9-CM code V60.0, VA specific codes for homeless services), plus closely allied V60 codes indicating housing instability. Logistic regression analyses examined differences between Veterans who received these codes. Health care services and co-morbidities were analyzed in the 90 days post-identification of homelessness. VA conventional criteria identified 21,021 homeless Veterans from Operations Enduring Freedom, Iraqi Freedom, and New Dawn (rate 2.5%). Adding allied V60 codes increased that to 31,260 (rate 3.3%). While certain demographic differences were noted, Veterans identified as homeless using conventional or allied codes were similar with regards to utilization of homeless, mental health, and substance abuse services, as well as co-morbidities. Differences were noted in the pattern of usage of homelessness-related diagnostic codes in VA facilities nation-wide. Creating an official VA case definition for homelessness, which would include additional ICD-9-CM and other administrative codes for VA homeless services, would likely allow improved identification of homeless and at-risk Veterans. This also presents an opportunity for encouraging uniformity in applying these codes in VA facilities nationwide as well as in other large health care organizations. PMID:26172386

  19. Use of the algebraic coding theory in nuclear electronics

    International Nuclear Information System (INIS)

    Nikityuk, N.M.

    1990-01-01

    New results of studies of the development and use of the syndrome coding method in nuclear electronics are described. Two aspects of using the syndrome coding method are considered for sequential coding devices and for the creation of fast parallel data compression devices. Specific examples of the creation of time-to-digital converters based on circular counters are described. Several time intervals can be coded very fast and with a high resolution by means of these converters. The effective coding matrix which can be used for light signal coding. The rule of constructing such coding matrices for arbitrary number of channels and multiplicity n is given. The methods for solving ambiguities in silicon detectors and for creating the special-purpose processors for high-energy spectrometers are given. 21 refs.; 9 figs.; 3 tabs

  20. Comparison of Thermal Creep Strain Calculation Results Using Time Hardening and Strain Hardening Rules

    International Nuclear Information System (INIS)

    Kim, Junehyung; Cheon, Jinsik; Lee, Byoungoon; Lee, Chanbock

    2014-01-01

    One of the design criteria for the fuel rod in PGSFR is the thermal creep strain of the cladding, because the cladding is exposed to a high temperature for a long time during reactor operation period. In general, there are two kind of calculation scheme for thermal creep strain: time hardening and strain hardening rules. In this work, thermal creep strain calculation results for HT9 cladding by using time hardening and strain hardening rules are compared by employing KAERI's current metallic fuel performance analysis code, MACSIS. Also, thermal creep strain calculation results by using ANL's metallic fuel performance analysis code, LIFE-METAL which adopts strain hardening rule are compared with those by using MACSIS. Thermal creep strain calculation results for HT9 cladding by using time hardening and strain hardening rules were compared by employing KAERI's current metallic fuel performance analysis code, MACSIS. Also, thermal creep strain calculation results by using ANL's metallic fuel performance analysis code, LIFE-METAL which adopts strain hardening rule were compared with those by using MACSIS. Tertiary creep started earlier in time hardening rule than in strain hardening rule. Also, calculation results by MACSIS with strain hardening and those obtained by using LIFE-METAL were almost identical to each other

  1. The utility of including pathology reports in improving the computational identification of patients

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2016-01-01

    Full Text Available Background: Celiac disease (CD is a common autoimmune disorder. Efficient identification of patients may improve chronic management of the disease. Prior studies have shown searching International Classification of Diseases-9 (ICD-9 codes alone is inaccurate for identifying patients with CD. In this study, we developed automated classification algorithms leveraging pathology reports and other clinical data in Electronic Health Records (EHRs to refine the subset population preselected using ICD-9 code (579.0. Materials and Methods: EHRs were searched for established ICD-9 code (579.0 suggesting CD, based on which an initial identification of cases was obtained. In addition, laboratory results for tissue transglutaminse were extracted. Using natural language processing we analyzed pathology reports from upper endoscopy. Twelve machine learning classifiers using different combinations of variables related to ICD-9 CD status, laboratory result status, and pathology reports were experimented to find the best possible CD classifier. Ten-fold cross-validation was used to assess the results. Results: A total of 1498 patient records were used including 363 confirmed cases and 1135 false positive cases that served as controls. Logistic model based on both clinical and pathology report features produced the best results: Kappa of 0.78, F1 of 0.92, and area under the curve (AUC of 0.94, whereas in contrast using ICD-9 only generated poor results: Kappa of 0.28, F1 of 0.75, and AUC of 0.63. Conclusion: Our automated classification system presented an efficient and reliable way to improve the performance of CD patient identification.

  2. Cross-cultural and comparative epidemiology of insomnia: the Diagnostic and statistical manual (DSM), International classification of diseases (ICD) and International classification of sleep disorders (ICSD).

    Science.gov (United States)

    Chung, Ka-Fai; Yeung, Wing-Fai; Ho, Fiona Yan-Yee; Yung, Kam-Ping; Yu, Yee-Man; Kwok, Chi-Wa

    2015-04-01

    To compare the prevalence of insomnia according to symptoms, quantitative criteria, and Diagnostic and Statistical Manual of Mental Disorders, 4th and 5th Edition (DSM-IV and DSM-5), International Classification of Diseases, 10th Revision (ICD-10), and International Classification of Sleep Disorders, 2nd Edition (ICSD-2), and to compare the prevalence of insomnia disorder between Hong Kong and the United States by adopting a similar methodology used by the America Insomnia Survey (AIS). Population-based epidemiological survey respondents (n = 2011) completed the Brief Insomnia Questionnaire (BIQ), a validated scale generating DSM-IV, DSM-5, ICD-10, and ICSD-2 insomnia disorder. The weighted prevalence of difficulty falling asleep, difficulty staying asleep, waking up too early, and non-restorative sleep that occurred ≥3 days per week was 14.0%, 28.3%, 32.1%, and 39.9%, respectively. When quantitative criteria were included, the prevalence dropped the most from 39.9% to 8.4% for non-restorative sleep, and the least from 14.0% to 12.9% for difficulty falling asleep. The weighted prevalence of DSM-IV, ICD-10, ICSD-2, and any of the three insomnia disorders was 22.1%, 4.7%, 15.1%, and 22.1%, respectively; for DSM-5 insomnia disorder, it was 10.8%. Compared with 22.1%, 3.9%, and 14.7% for DSM-IV, ICD-10, and ICSD-2 in the AIS, cross-cultural difference in the prevalence of insomnia disorder is less than what is expected. The prevalence is reduced by half from DSM-IV to DSM-5. ICD-10 insomnia disorder has the lowest prevalence, perhaps because excessive concern and preoccupation, one of its diagnostic criteria, is not always present in people with insomnia. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Proposal to modify Rule 10a and to delete Recommendation 10a(3) from the International Code of Nomenclature of Prokaryotes.

    Science.gov (United States)

    Oren, Aharon

    2017-09-01

    Principle 2 of the Prokaryotic Code, as modified by the ICSP in 1999, reads: 'The nomenclature of prokaryotes is not independent of botanical and zoological nomenclature. When naming new taxa in the rank of genus or higher, due consideration is to be given to avoiding names which are regulated by the International Code of Zoological Nomenclature and the International Code of Nomenclature for algae, fungi and plants'. But in the current version of the Prokaryotic Code no Rule implements this version of Principle 2. I therefore propose adding the following sentence to Rule 10a: 'As from January 2001, newly proposed generic names must not be later homonyms of names in use in botany or zoology'. Recommendation 10a(3) of the Code states: 'Avoid introducing into bacteriology as generic names such names as are in use in botany or zoology, in particular well-known names'. This Recommendation contravenes the current version of Principle 2 and the proposed new version of Rule 10a. Therefore I propose to delete Recommendation 10a(3) from the Prokaryotic Code.

  4. A neutron spectrum unfolding code based on iterative procedures

    International Nuclear Information System (INIS)

    Ortiz R, J. M.; Vega C, H. R.

    2012-10-01

    In this work, the version 3.0 of the neutron spectrum unfolding code called Neutron Spectrometry and Dosimetry from Universidad Autonoma de Zacatecas (NSDUAZ), is presented. This code was designed in a graphical interface under the LabVIEW programming environment and it is based on the iterative SPUNIT iterative algorithm, using as entrance data, only the rate counts obtained with 7 Bonner spheres based on a 6 Lil(Eu) neutron detector. The main features of the code are: it is intuitive and friendly to the user; it has a programming routine which automatically selects the initial guess spectrum by using a set of neutron spectra compiled by the International Atomic Energy Agency. Besides the neutron spectrum, this code calculates the total flux, the mean energy, H(10), h(10), 15 dosimetric quantities for radiation protection porpoises and 7 survey meter responses, in four energy grids, based on the International Atomic Energy Agency compilation. This code generates a full report in html format with all relevant information. In this work, the neutron spectrum of a 241 AmBe neutron source on air, located at 150 cm from detector, is unfolded. (Author)

  5. Does ICD indication affect quality of life and levels of distress?

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Sears, Samuel F; Burg, Matthew M

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is the treatment of choice for life-threatening arrhythmias, with ICD indications having recently been extended to include primary prophylaxis. Despite the medical benefits of the ICD, there is an ongoing debate as to the impact of the ICD on patie...

  6. Impulse control disorders and related behaviours (ICD-RBs in Parkinson′s disease patients: Assessment using “Questionnaire for impulsive-compulsive disorders in Parkinson′s disease” (QUIP

    Directory of Open Access Journals (Sweden)

    Ashish Sharma

    2015-01-01

    Full Text Available Background: There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs in Indian patients with Parkinson′s Disease (PD. In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. Objectives: To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated “Questionnaire for Impulsive-Compulsive Disorders in Parkinson′s disease (QUIP” and to examine their association with Dopamine replacement therapy (DRT. Materials and Methods: This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Results: Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%, at least one Impulse control disorder (ICD was present in 74 (24.75% and at least one Impulse control related compulsive behaviour (ICRB was present in 93 (31.1% patients. Punding was the most frequent (12.4% followed by hyper sexuality (11.04%, compulsive hobbyism (9.4%, compulsive shopping (8.4%, compulsive medication use (7.7%, compulsive eating (5.35%, walkabout (4% and pathological gambling (3.3%. ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Conclusions: Our study revealed a relatively higher

  7. Impact of the diagnostic changes to post-traumatic stress disorder for DSM-5 and the proposed changes to ICD-11.

    Science.gov (United States)

    O'Donnell, Meaghan L; Alkemade, Nathan; Nickerson, Angela; Creamer, Mark; McFarlane, Alexander C; Silove, Derrick; Bryant, Richard A; Forbes, David

    2014-09-01

    There have been changes to the criteria for diagnosing post-traumatic stress disorder (PTSD) in DSM-5 and changes are proposed for ICD-11. To investigate the impact of the changes to diagnostic criteria for PTSD in DSM-5 and the proposed changes in ICD-11 using a large multisite trauma-exposed sample and structured clinical interviews. Randomly selected injury patients admitted to four hospitals were assessed 72 months post trauma (n = 510). Structured clinical interviews for PTSD and major depressive episode, as well as self-report measures of disability and quality of life were administered. Current prevalence of PTSD under DSM-5 scoring was not significantly different from DSM-IV (6.7% v. 5.9%, z = 0.53, P = 0.59). However, the ICD-11 prevalence was significantly lower than ICD-10 (3.3% v. 9.0%, z = -3.8, PDSM-5 than ICD-11 (6.7% v. 3.3%, z = 2.5, P = 0.01). Using ICD-11 tended to show lower rates of comorbidity with depression and a slightly lower association with disability. The diagnostic systems performed in different ways in terms of current prevalence rates and levels of comorbidity with depression, but on other broad key indicators they were relatively similar. There was overlap between those with PTSD diagnosed by ICD-11 and DSM-5 but a substantial portion met one but not the other set of criteria. This represents a challenge for research because the phenotype that is studied may be markedly different according to the diagnostic system used. Royal College of Psychiatrists.

  8. The accuracy of International Classification of Diseases coding for dental problems not associated with trauma in a hospital emergency department.

    Science.gov (United States)

    Figueiredo, Rafael L F; Singhal, Sonica; Dempster, Laura; Hwang, Stephen W; Quinonez, Carlos

    2015-01-01

    Emergency department (ED) visits for nontraumatic dental conditions (NTDCs) may be a sign of unmet need for dental care. The objective of this study was to determine the accuracy of the International Classification of Diseases codes (ICD-10-CA) for ED visits for NTDC. ED visits in 2008-2099 at one hospital in Toronto were identified if the discharge diagnosis in the administrative database system was an ICD-10-CA code for a NTDC (K00-K14). A random sample of 100 visits was selected, and the medical records for these visits were reviewed by a dentist. The description of the clinical signs and symptoms were evaluated, and a diagnosis was assigned. This diagnosis was compared with the diagnosis assigned by the physician and the code assigned to the visit. The 100 ED visits reviewed were associated with 16 different ICD-10-CA codes for NTDC. Only 2 percent of these visits were clearly caused by trauma. The code K0887 (toothache) was the most frequent diagnostic code (31 percent). We found 43.3 percent disagreement on the discharge diagnosis reported by the physician, and 58.0 percent disagreement on the code in the administrative database assigned by the abstractor, compared with what it was suggested by the dentist reviewing the chart. There are substantial discrepancies between the ICD-10-CA diagnosis assigned in administrative databases and the diagnosis assigned by a dentist reviewing the chart retrospectively. However, ICD-10-CA codes can be used to accurately identify ED visits for NTDC. © 2015 American Association of Public Health Dentistry.

  9. Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD: Design and Rationale of the EFFORTLESS S-ICD Registry

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Lambiase, Pier; Boersma, Lucas V A

    2012-01-01

    utilization. Methods: The Registry is an observational, nonrandomized, standard of care evaluation to be conducted at approximately 50 investigational centers in Europe and New Zealand where the S-ICD is approved for use and distribution. Clinical Registry endpoints include perioperative (30 days postimplant......Background: Leads in and on the heart of the transvenous implantable cardioverter defibrillator (ICD) form the Achilles' heel of this system due to potential for peri- and postimplant complications. The S-ICD is a newer generation of the ICD that does not require leads on the heart...... or in the vasculature. We present the rationale and study design of the Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD (EFFORTLESS S-ICD) Registry which was designed to evaluate the long-term performance of the S-ICD including patient quality of life and long-term resource...

  10. Gender Incongruence of Childhood: Clinical Utility and Stakeholder Agreement with the World Health Organization’s Proposed ICD-11 Criteria

    Science.gov (United States)

    Beek, Titia F.; Cohen-Kettenis, Peggy T.; Bouman, Walter P.; de Vries, Annelou L. C.; Steensma, Thomas D.; Witcomb, Gemma L.; Arcelus, Jon; Richards, Christina; De Cuypere, Griet; Kreukels, Baudewijntje P. C.

    2017-01-01

    The World Health Organization (WHO) is revising the tenth version of the International Classification of Diseases and Related Health Problems (ICD-10). This includes a reconceptualization of the definition and positioning of Gender Incongruence of Childhood (GIC). This study aimed to: 1) collect the views of transgender individuals and professionals regarding the retention of the diagnosis; 2) see if the proposed GIC criteria were acceptable to transgender individuals and health care providers; 3) compare results between two countries with two different healthcare systems to see if these differences influence opinions regarding the GIC diagnosis; and 4) determine whether healthcare providers from high-income countries feel that the proposed criteria are clinically useful and easy to use. A total of 628 participants were included in the study: 284 from the Netherlands (NL; 45.2%), 8 from Flanders (Belgium; 1.3%), and 336 (53.5%) from the United Kingdom (UK). Most participants were transgender people (or their partners/relatives; TG) (n = 522), 89 participants were healthcare providers (HCPs) and 17 were both HCP and TG individuals. Participants completed an online survey developed for this study. Overall, the majority response from transgender participants (42.9%) was that if the diagnosis would be removed from the mental health chapter it should also be removed from the ICD-11 completely, while 33.6% thought it should remain in the ICD-11. Participants were generally satisfied with other aspects of the proposed ICD-11 GIC diagnosis: most TG participants (58.4%) thought the term Gender Identity Disorder should change, and most thought Gender Incongruence was an improvement (63.0%). Furthermore, most participants (76.1%) did not consider GIC to be a psychiatric disorder and placement in a separate chapter dealing with Gender and Sexual Health (the majority response in the NL and selected by 37.5% of the TG participants overall) or as a Z-code (the majority response

  11. Collaboration between specialties for respiratory allergies in the International Classification of Diseases (ICD)-11.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises; Linzer, Jeffrey F; Chalmers, Robert J G; Demoly, Pascal

    2017-02-10

    The International Classification of Diseases (ICD) has been grouping the allergic and hypersensitivity disorders involving the respiratory tract under topographic distribution, regardless of the underlying mechanisms, triggers or concepts currently in use for allergic and hypersensitivity conditions. In order to strengthen awareness and deliberate the creation of the new "Allergic or hypersensitivity disorders involving the respiratory tract" section of the ICD-11, we here propose make the building process public. The new frame has been constructed to cover the gaps previously identified and was based on consensus academic reports and ICD-11 principles. Constant and bilateral discussion was kept with relevant groups representing specialties and resulted in proposals submission into the ICD-11 online platform. The "Allergic or hypersensitivity disorders involving the respiratory tract" section covers 64 entities distributed across five main categories. All the 79 proposals submitted resulted from an intensive collaboration of the Allergy working group, relevant Expert working groups and the WHO ICD governance. The establishment of the ICD-11 "Allergic or hypersensitivity disorders involving the respiratory tract" section will allow the dissemination of the updated concepts to be used in clinical practice by many different specialties and health professionals.

  12. Echocardiography and cardiac MRI in mutation-negative hypertrophic cardiomyopathy in an older patient: a case defining the need for ICD.

    Science.gov (United States)

    Rodriguez, Fatima; Degnan, Kathleen O; Seidman, Christine E; Mangion, Judy R

    2014-08-01

    We report the case of a 67-year-old man with hypertrophic cardiomyopathy who presented for a second opinion about implantable cardio-defibrillator (ICD) placement after a witnessed syncopal episode. Despite his older age, being mutation-negative, and having a maximal septal thickness of 2.2 cm on echocardiography, he demonstrated rapid progression of myocardial fibrosis on cardiac MRI, correlating to ventricular tachyarrhythmias and syncope. We review the role of echocardiography and cardiac MRI in optimizing medical care for such patients who may not otherwise meet criteria for an ICD placement or further interventions. © 2014, Wiley Periodicals, Inc.

  13. Automated Assessment of Existing Patient's Revised Cardiac Risk Index Using Algorithmic Software.

    Science.gov (United States)

    Hofer, Ira S; Cheng, Drew; Grogan, Tristan; Fujimoto, Yohei; Yamada, Takashige; Beck, Lauren; Cannesson, Maxime; Mahajan, Aman

    2018-05-25

    Previous work in the field of medical informatics has shown that rules-based algorithms can be created to identify patients with various medical conditions; however, these techniques have not been compared to actual clinician notes nor has the ability to predict complications been tested. We hypothesize that a rules-based algorithm can successfully identify patients with the diseases in the Revised Cardiac Risk Index (RCRI). Patients undergoing surgery at the University of California, Los Angeles Health System between April 1, 2013 and July 1, 2016 and who had at least 2 previous office visits were included. For each disease in the RCRI except renal failure-congestive heart failure, ischemic heart disease, cerebrovascular disease, and diabetes mellitus-diagnosis algorithms were created based on diagnostic and standard clinical treatment criteria. For each disease state, the prevalence of the disease as determined by the algorithm, International Classification of Disease (ICD) code, and anesthesiologist's preoperative note were determined. Additionally, 400 American Society of Anesthesiologists classes III and IV cases were randomly chosen for manual review by an anesthesiologist. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve were determined using the manual review as a gold standard. Last, the ability of the RCRI as calculated by each of the methods to predict in-hospital mortality was determined, and the time necessary to run the algorithms was calculated. A total of 64,151 patients met inclusion criteria for the study. In general, the incidence of definite or likely disease determined by the algorithms was higher than that detected by the anesthesiologist. Additionally, in all disease states, the prevalence of disease was always lowest for the ICD codes, followed by the preoperative note, followed by the algorithms. In the subset of patients for whom the

  14. 9 CFR 202.113 - Rule 13: Written hearing.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Rule 13: Written hearing. 202.113 Section 202.113 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS ADMINISTRATION... waiver of the right to file such evidence. (g) Extension of time for depositions. If any party timely...

  15. Hypothyroidism Among Military Infants Born in Countries of Varied Iodine Nutrition Status

    Science.gov (United States)

    2010-02-01

    while permanent congenital hypothyroidism causes include thyroid dysgenesis, dys- hormonogenesis, and central hypothyroidism and is relatively rare, with... causes have found a gender influence only among permanent cases of congenital hypothyroidism [15,20]. Given our use of ICD-9-CM codes to define cases...Naval Health Research Center Hypothyroidism among Military Infants Born in Countries of Varied Iodine Nutrition Status . M. M. Cranston

  16. Medical Surveillance Monthly Report (MSMR). Volume 17, Number 08, August 2010

    Science.gov (United States)

    2010-08-01

    Gonorrhea Syphilis AUGUST 2010 3 p-yrs, respectively; the rate of syphilis was much lower than the rates of the other STIs considered here (overall...were among 20-24 year olds (Figures 2b,c). Gonorrhea Rates of gonorrhea were relatively stable throughout the period (range: 221.9 to 239.5 cases...notifi able medical event reports that included diagnostic codes (ICD-9-CM) indicative of chlamydia, gonorrhea , syphilis, herpes simplex virus (HSV

  17. Erasmus MC at CLEF eHealth 2016: Concept recognition and coding in French texts

    NARCIS (Netherlands)

    E.M. Van Mulligen (Erik M.); Z. Afzal (Zubair); S.A. Akhondi (Saber); D. Vo (Dang); J.A. Kors (Jan)

    2016-01-01

    textabstractWe participated in task 2 of the CLEF eHealth 2016 chal-lenge. Two subtasks were addressed: entity recognition and normalization in a corpus of French drug labels and Medline titles, and ICD-10 coding of French death certificates. For both subtasks we used a dictionary-based approach.

  18. Verification of business rules programs

    CERN Document Server

    Silva, Bruno Berstel-Da

    2013-01-01

    Rules represent a simplified means of programming, congruent with our understanding of human brain constructs. With the advent of business rules management systems, it has been possible to introduce rule-based programming to nonprogrammers, allowing them to map expert intent into code in applications such as fraud detection, financial transactions, healthcare, retail, and marketing. However, a remaining concern is the quality, safety, and reliability of the resulting programs.  This book is on business rules programs, that is, rule programs as handled in business rules management systems. Its

  19. Severity of depressive episodes according to ICD-10

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel

    2004-01-01

    BACKGROUND: The ICD-10 categorisation of severity of depression into mild, moderate and severe depressive episodes has not been validated. AIMS: To validate the ICD-10 categorisation of severity of depression by estimating its predictive ability on the course of illness and suicidal outcome. METHOD......: All psychiatric in-patients in Denmark who had received a diagnosis of a single depressive episode at their first discharge between 1994 and 1999 were identified. The risk of relapse and the risk of suicide were compared for patients discharged with an ICD-10 diagnosis of a single mild, moderate...... or severe depressive episode. RESULTS: At their first discharge, 1103 patients had an ICD-10 diagnosis of mild depressive episode, 3182 had a diagnosis of moderate depressive episode and 2914 had a diagnosis of severe depressive episode. The risk of relapse and the risk of suicide were significantly...

  20. RCC-F: Design and construction rules for PWR fire protection systems

    International Nuclear Information System (INIS)

    2013-01-01

    The RCC-F code defines the rules for designing, building and installing the fire protection systems used to manage the nuclear hazards inherent in the outbreak of a fire inside the facility and thereby control the fundamental nuclear functions. The code provides fire protection recommendations in terms of: the industrial risk (loss of assets and/or operation), personnel safety, the environment. The code is divided into five main sections: generalities, design safety principles, fire protection design bases, construction provisions, rules for installing the fire protection components and equipment. The RCC-F code is available as an ETC-F version specifically for EPR projects (European pressurized reactor). Contents of the 2013 edition of the ETC-F code: Volume A - Generalities: Structure of ETC-F general points, documentation (in progress), chapter (provision) quality assurance; Volume B - Design safety principles: design nuclear safety principles; Volume C - Fire protection design bases: fire protection design bases; Volume D - Construction provisions: construction provisions; Volume E - Installation rules for fire protection: rules for installing the fire protection, components and equipment

  1. LSB-Based Steganography Using Reflected Gray Code

    Science.gov (United States)

    Chen, Chang-Chu; Chang, Chin-Chen

    Steganography aims to hide secret data into an innocuous cover-medium for transmission and to make the attacker cannot recognize the presence of secret data easily. Even the stego-medium is captured by the eavesdropper, the slight distortion is hard to be detected. The LSB-based data hiding is one of the steganographic methods, used to embed the secret data into the least significant bits of the pixel values in a cover image. In this paper, we propose an LSB-based scheme using reflected-Gray code, which can be applied to determine the embedded bit from secret information. Following the transforming rule, the LSBs of stego-image are not always equal to the secret bits and the experiment shows that the differences are up to almost 50%. According to the mathematical deduction and experimental results, the proposed scheme has the same image quality and payload as the simple LSB substitution scheme. In fact, our proposed data hiding scheme in the case of G1 (one bit Gray code) system is equivalent to the simple LSB substitution scheme.

  2. 3.56-bits/cm Compact Inkjet Printed and Application Specific Chipless RFID Tag

    KAUST Repository

    Khan, Munawar M.

    2015-10-26

    © 2002-2011 IEEE. In this letter, a 28.5-bit chipless RFID tag, based on paper substrate and realized using inkjet printing technique is presented. Operating within ultrawideband, the tag occupies a compact size of 2 × 4 cm2. Focusing on applications requiring time and date identification, a novel encoding technique is presented that allows efficient frequency band allocation based on the number of required instances of time and date variables. A figure of merit (FOM) relating coding capacity and tag dimensions coined as code density is also introduced. A systematic design process followed by simulations and verified through measurements reveal a high code density of 3.56 bits/cm2 for the presented chipless tag.

  3. Sequence-based heuristics for faster annotation of non-coding RNA families.

    Science.gov (United States)

    Weinberg, Zasha; Ruzzo, Walter L

    2006-01-01

    Non-coding RNAs (ncRNAs) are functional RNA molecules that do not code for proteins. Covariance Models (CMs) are a useful statistical tool to find new members of an ncRNA gene family in a large genome database, using both sequence and, importantly, RNA secondary structure information. Unfortunately, CM searches are extremely slow. Previously, we created rigorous filters, which provably sacrifice none of a CM's accuracy, while making searches significantly faster for virtually all ncRNA families. However, these rigorous filters make searches slower than heuristics could be. In this paper we introduce profile HMM-based heuristic filters. We show that their accuracy is usually superior to heuristics based on BLAST. Moreover, we compared our heuristics with those used in tRNAscan-SE, whose heuristics incorporate a significant amount of work specific to tRNAs, where our heuristics are generic to any ncRNA. Performance was roughly comparable, so we expect that our heuristics provide a high-quality solution that--unlike family-specific solutions--can scale to hundreds of ncRNA families. The source code is available under GNU Public License at the supplementary web site.

  4. Comparing the use of SNOMED CT and ICD10 for coding clinical conditions to implement laboratory guidelines.

    Science.gov (United States)

    Yasini, Mobin; Ebrahiminia, Vahid; Duclos, Catherine; Venot, Alain; Lamy, Jean-Baptiste

    2013-01-01

    Laboratory medicine is responsible for an important part of hospital expenditure. Providing appropriate decision support to laboratory test requesters at the point of care is one of the main incentives for implementing laboratory guidelines, which can improve medical care. Laboratory guidelines developed by local experts in the Parisian region and two national guidelines for dyslipidemia were analyzed to extract test ordering recommendations. Clinical conditions which can be a trigger to order or not to order laboratory tests were extracted and mapped with ICD10 and SNOMED CT: 43.1% of clinical conditions were matched by ICD10 whereas SNOMED CT covered 80.1% of these conditions. For the non-mapped conditions, the main problem was found to be the ambiguity of the terms used in the guidelines. Ordinal characteristics of some clinical conditions and using terms more specific than SNOMED CT were other causes of mapping failure. Applying consistent and explicit concepts in the development of guidelines would lead to better implementation. By resolving the guideline ambiguity, SNOMED CT is a good choice and covers almost all of the clinical conditions in laboratory guidelines which are needed to implement in a Clinical Decision Support System.

  5. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

    Science.gov (United States)

    Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P

    2015-10-01

    Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.

  6. Using clinical data to predict high-cost performance coding issues associated with pressure ulcers: a multilevel cohort model.

    Science.gov (United States)

    Padula, William V; Gibbons, Robert D; Pronovost, Peter J; Hedeker, Donald; Mishra, Manish K; Makic, Mary Beth F; Bridges, John Fp; Wald, Heidi L; Valuck, Robert J; Ginensky, Adam J; Ursitti, Anthony; Venable, Laura Ruth; Epstein, Ziv; Meltzer, David O

    2017-04-01

    Hospital-acquired pressure ulcers (HAPUs) have a mortality rate of 11.6%, are costly to treat, and result in Medicare reimbursement penalties. Medicare codes HAPUs according to Agency for Healthcare Research and Quality Patient-Safety Indicator 3 (PSI-03), but they are sometimes inappropriately coded. The objective is to use electronic health records to predict pressure ulcers and to identify coding issues leading to penalties. We evaluated all hospitalized patient electronic medical records at an academic medical center data repository between 2011 and 2014. These data contained patient encounter level demographic variables, diagnoses, prescription drugs, and provider orders. HAPUs were defined by PSI-03: stages III, IV, or unstageable pressure ulcers not present on admission as a secondary diagnosis, excluding cases of paralysis. Random forests reduced data dimensionality. Multilevel logistic regression of patient encounters evaluated associations between covariates and HAPU incidence. The approach produced a sample population of 21 153 patients with 1549 PSI-03 cases. The greatest odds ratio (OR) of HAPU incidence was among patients diagnosed with spinal cord injury (ICD-9 907.2: OR = 14.3; P  coded for paralysis, leading to a PSI-03 flag. Other high ORs included bed confinement (ICD-9 V49.84: OR = 3.1, P  coded without paralysis, leading to PSI-03 flags. The resulting statistical model can be tested to predict HAPUs during hospitalization. Inappropriate coding of conditions leads to poor hospital performance measures and Medicare reimbursement penalties. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Impact of unlinked deaths and coding changes on mortality trends in the Swiss National Cohort.

    Science.gov (United States)

    Schmidlin, Kurt; Clough-Gorr, Kerri M; Spoerri, Adrian; Egger, Matthias; Zwahlen, Marcel

    2013-01-04

    Results of epidemiological studies linking census with mortality records may be affected by unlinked deaths and changes in cause of death classification. We examined these issues in the Swiss National Cohort (SNC). The SNC is a longitudinal study of the entire Swiss population, based on the 1990 (6.8 million persons) and 2000 (7.3 million persons) censuses. Among 1,053,393 deaths recorded 1991-2007 5.4% could not be linked using stringent probabilistic linkage. We included the unlinked deaths using pragmatic linkages and compared mortality rates for selected causes with official mortality rates. We also examined the impact of the 1995 change in cause of death coding from version 8 (with some additional rules) to version 10 of the International Classification of Diseases (ICD), using Poisson regression models with restricted cubic splines. Finally, we compared results from Cox models including and excluding unlinked deaths of the association of education, marital status, and nationality with selected causes of death. SNC mortality rates underestimated all cause mortality by 9.6% (range 2.4%-17.9%) in the 85+ population. Underestimation was less pronounced in years nearer the censuses and in the 75-84 age group. After including 99.7% of unlinked deaths, annual all cause SNC mortality rates were reflecting official rates (relative difference between -1.4% and +1.8%). In the 85+ population the rates for prostate and breast cancer dropped, by 16% and 21% respectively, between 1994 and 1995 coincident with the change in cause of death coding policy. For suicide in males almost no change was observed. Hazard ratios were only negligibly affected by including the unlinked deaths. A sudden decrease in breast (21% less, 95% confidence interval: 12%-28%) and prostate (16% less, 95% confidence interval: 7%-23%) cancer mortality rates in the 85+ population coincided with the 1995 change in cause of death coding policy. Unlinked deaths bias analyses of absolute mortality rates

  8. Impact of unlinked deaths and coding changes on mortality trends in the Swiss National Cohort

    Directory of Open Access Journals (Sweden)

    Schmidlin Kurt

    2013-01-01

    Full Text Available Abstract Background Results of epidemiological studies linking census with mortality records may be affected by unlinked deaths and changes in cause of death classification. We examined these issues in the Swiss National Cohort (SNC. Methods The SNC is a longitudinal study of the entire Swiss population, based on the 1990 (6.8 million persons and 2000 (7.3 million persons censuses. Among 1,053,393 deaths recorded 1991–2007 5.4% could not be linked using stringent probabilistic linkage. We included the unlinked deaths using pragmatic linkages and compared mortality rates for selected causes with official mortality rates. We also examined the impact of the 1995 change in cause of death coding from version 8 (with some additional rules to version 10 of the International Classification of Diseases (ICD, using Poisson regression models with restricted cubic splines. Finally, we compared results from Cox models including and excluding unlinked deaths of the association of education, marital status, and nationality with selected causes of death. Results SNC mortality rates underestimated all cause mortality by 9.6% (range 2.4% - 17.9% in the 85+ population. Underestimation was less pronounced in years nearer the censuses and in the 75–84 age group. After including 99.7% of unlinked deaths, annual all cause SNC mortality rates were reflecting official rates (relative difference between −1.4% and +1.8%. In the 85+ population the rates for prostate and breast cancer dropped, by 16% and 21% respectively, between 1994 and 1995 coincident with the change in cause of death coding policy. For suicide in males almost no change was observed. Hazard ratios were only negligibly affected by including the unlinked deaths. A sudden decrease in breast (21% less, 95% confidence interval: 12% - 28% and prostate (16% less, 95% confidence interval: 7% - 23% cancer mortality rates in the 85+ population coincided with the 1995 change in cause of death coding policy

  9. National assessment of validity of coding of acute mastoiditis: a standardised reassessment of 1966 records.

    Science.gov (United States)

    Stalfors, J; Enoksson, F; Hermansson, A; Hultcrantz, M; Robinson, Å; Stenfeldt, K; Groth, A

    2013-04-01

    To investigate the internal validity of the diagnosis code used at discharge after treatment of acute mastoiditis. Retrospective national re-evaluation study of patient records 1993-2007 and make comparison with the original ICD codes. All ENT departments at university hospitals and one large county hospital department in Sweden. A total of 1966 records were reviewed for patients with ICD codes for in-patient treatment of acute (529), chronic (44) and unspecified mastoiditis (21) and acute otitis media (1372). ICD codes were reviewed by the authors with a defined protocol for the clinical diagnosis of acute mastoiditis. Those not satisfying the diagnosis were given an alternative diagnosis. Of 529 records with ICD coding for acute mastoiditis, 397 (75%) were found to meet the definition of acute mastoiditis used in this study, while 18% were not diagnosed as having any type of mastoiditis after review. Review of the in-patients treated for acute media otitis identified an additional 60 cases fulfilling the definition of acute mastoiditis. Overdiagnosis was common, and many patients with a diagnostic code indicating acute mastoiditis had been treated for external otitis or otorrhoea with transmyringeal drainage. The internal validity of the diagnosis acute mastoiditis is dependent on the use of standardised, well-defined criteria. Reliability of diagnosis is fundamental for the comparison of results from different studies. Inadequate reliability in the diagnosis of acute mastoiditis also affects calculations of incidence rates and statistical power and may also affect the conclusions drawn from the results. © 2013 Blackwell Publishing Ltd.

  10. The Spanish national health care-associated infection surveillance network (INCLIMECC): data summary January 1997 through December 2006 adapted to the new National Healthcare Safety Network Procedure-associated module codes.

    Science.gov (United States)

    Pérez, Cristina Díaz-Agero; Rodela, Ana Robustillo; Monge Jodrá, Vincente

    2009-12-01

    In 1997, a national standardized surveillance system (designated INCLIMECC [Indicadores Clínicos de Mejora Continua de la Calidad]) was established in Spain for health care-associated infection (HAI) in surgery patients, based on the National Nosocomial Infection Surveillance (NNIS) system. In 2005, in its procedure-associated module, the National Healthcare Safety Network (NHSN) inherited the NNIS program for surveillance of HAI in surgery patients and reorganized all surgical procedures. INCLIMECC actively monitors all patients referred to the surgical ward of each participating hospital. We present a summary of the data collected from January 1997 to December 2006 adapted to the new NHSN procedures. Surgical site infection (SSI) rates are provided by operative procedure and NNIS risk index category. Further quality indicators reported are surgical complications, length of stay, antimicrobial prophylaxis, mortality, readmission because of infection or other complication, and revision surgery. Because the ICD-9-CM surgery procedure code is included in each patient's record, we were able to reorganize our database avoiding the loss of extensive information, as has occurred with other systems.

  11. ICDE project report on collection and analysis of common-cause failures of centrifugal pumps

    International Nuclear Information System (INIS)

    2000-01-01

    Several member countries of OECD/NEA decided to establish the International Common-Cause Failure Data Exchange (ICDE) Project to encourage multilateral co-operation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The project was initiated in August 1994 in Sweden and was discussed at meetings in both Sweden and France in 1995. A coding benchmark exercise was defined which was evaluated at meetings held in Germany and in the US in 1996. Subsequently, the exchange of centrifugal pump data was defined; the first phase of this exchange was evaluated at meetings in Switzerland and in France in 1997. The objectives of the ICDE Project are: - to collect and analyse CCF events in the long term so as to better understand such events, their causes, and their prevention, - to generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences, - to establish a mechanism for the efficient feedback of experience gained on CCF phenomena, including the development of defences against their occurrence, such as indicators for risk based inspections. The ICDE Project is envisaged as including all possible events of interest, comprising complete, partial and incipient CCF events, called 'ICDE events' in the following. The Project covers the key components of the main safety systems, like centrifugal pumps, diesel generators, motor operated valves, power operated relief valves, safety relief valves, check valves, RPS circuit breakers, batteries and transmitters. Data are collected in an MS ACCESS based databank implemented and maintained at ES-Konsult, Sweden, by NEA appointed clearinghouse. The databank is regularly updated. The clearinghouse and the project group operate it. In the modelling of common-cause failures in systems consisting of several redundant components, two kinds of events are distinguished: a) Unavailability of a

  12. Materials and design bases issues in ASME Code Case N-47

    International Nuclear Information System (INIS)

    Huddleston, R.L.; Swindeman, R.W.

    1993-04-01

    A preliminary evaluation of the design bases (principally ASME Code Case N-47) was conducted for design and operation of reactors at elevated temperatures where the time-dependent effects of creep, creep-fatigue, and creep ratcheting are significant. Areas where Code rules or regulatory guides may be lacking or inadequate to ensure the operation over the expected life cycles for the next-generation advanced high-temperature reactor systems, with designs to be certified by the US Nuclear Regulatory Commission, have been identified as unresolved issues. Twenty-two unresolved issues were identified and brief scoping plans developed for resolving these issues

  13. Posttraumatic Stress Disorder and Complex Posttraumatic Stress Disorder in DSM-5 and ICD-11: Clinical and Behavioral Correlates.

    Science.gov (United States)

    Hyland, Philip; Shevlin, Mark; Fyvie, Claire; Karatzias, Thanos

    2018-04-01

    The American Psychiatric Association and the World Health Organization provide distinct trauma-based diagnoses in the fifth edition of the Diagnostic and Statistical Manual (DSM-5), and the forthcoming 11th version of the International Classification of Diseases (ICD-11), respectively. The DSM-5 conceptualizes posttraumatic stress disorder (PTSD) as a single, broad diagnosis, whereas the ICD-11 proposes two "sibling" disorders: PTSD and complex PTSD (CPTSD). The objectives of the current study were to: (a) compare prevalence rates of PTSD/CPTSD based on each diagnostic system; (b) identify clinical and behavioral variables that distinguish ICD-11 CPTSD and PTSD diagnoses; and (c) examine the diagnostic associations for ICD-11 CPTSD and DSM-5 PTSD. Participants in a predominately female clinical sample (N = 106) completed self-report scales to measure ICD-11 PTSD and CPTSD, DSM-5 PTSD, and depression, anxiety, borderline personality disorder, dissociation, destructive behaviors, and suicidal ideation and self-harm. Significantly more people were diagnosed with PTSD according to the DSM-5 criteria (90.4%) compared to those diagnosed with PTSD and CPTSD according to the ICD-11 guidelines (79.8%). An ICD-11 CPTSD diagnosis was distinguished from an ICD-11 PTSD diagnosis by higher levels of dissociation (d = 1.01), depression (d = 0.63), and borderline personality disorder (d = 0.55). Diagnostic associations with depression, anxiety, and suicidal ideation and self-harm were higher for ICD-11 CPTSD compared to DSM-5 PTSD (by 10.7%, 4.0%, and 7.0%, respectively). These results have implications for differential diagnosis and for the development of targeted treatments for CPTSD. Copyright © 2018 International Society for Traumatic Stress Studies.

  14. Sexual concerns and practices after ICD implantation

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Elleman-Jensen, Line; Zwisler, Ann-Dorthe

    2013-01-01

    given about sexual activity, (b) the areas of patient concerns related to sexual function and the ICD, and (c) changes in sexual behavior.Methods:A randomized controlled trial including 196 patients (1:1) was designed, including 12 weeks of exercise training and 1 year of psycho-educational follow......Background:Studies show that patients with implantable cardioverter defibrillators (ICD) frequently experience sexual dysfunction. These experiences are often linked to exercise intolerance, side-effects of medication, and psychological problems.Objective:To describe (a) the level of information......-up focusing on modifiable factors associated with poor outcomes, including sexual functioning. The Sex After ICD Survey was administered 6 months after the randomization as part of the planned explorative outcomes. 141 patients responded.Results:The analyses showed that 37 of the 69 (55.2%) patients...

  15. Aircrew Availability: Modeling Predictors of Duties Not Including Flying Status

    Science.gov (United States)

    2017-07-25

    and Utilization Project (HCUP). The Clinical Classification Software ( CCS ) for ICD-9-CM aids analysts to collapse diagnostic data from over 14,000...interquartile range. aOnly AFSCs comprising 80% of participants shown for brevity. bHCUP- CCS secondary level diagnosis categories shown for brevity. 7...Aug 2017. LIST OF ABBREVIATIONS AND ACRONYMS AFSC Air Force Specialty Code ASIMS Aeromedical Services Information Management System CCS

  16. Genetic learning in rule-based and neural systems

    Science.gov (United States)

    Smith, Robert E.

    1993-01-01

    The design of neural networks and fuzzy systems can involve complex, nonlinear, and ill-conditioned optimization problems. Often, traditional optimization schemes are inadequate or inapplicable for such tasks. Genetic Algorithms (GA's) are a class of optimization procedures whose mechanics are based on those of natural genetics. Mathematical arguments show how GAs bring substantial computational leverage to search problems, without requiring the mathematical characteristics often necessary for traditional optimization schemes (e.g., modality, continuity, availability of derivative information, etc.). GA's have proven effective in a variety of search tasks that arise in neural networks and fuzzy systems. This presentation begins by introducing the mechanism and theoretical underpinnings of GA's. GA's are then related to a class of rule-based machine learning systems called learning classifier systems (LCS's). An LCS implements a low-level production-system that uses a GA as its primary rule discovery mechanism. This presentation illustrates how, despite its rule-based framework, an LCS can be thought of as a competitive neural network. Neural network simulator code for an LCS is presented. In this context, the GA is doing more than optimizing and objective function. It is searching for an ecology of hidden nodes with limited connectivity. The GA attempts to evolve this ecology such that effective neural network performance results. The GA is particularly well adapted to this task, given its naturally-inspired basis. The LCS/neural network analogy extends itself to other, more traditional neural networks. Conclusions to the presentation discuss the implications of using GA's in ecological search problems that arise in neural and fuzzy systems.

  17. The Design of Artificial Intelligence Robot Based on Fuzzy Logic Controller Algorithm

    Science.gov (United States)

    Zuhrie, M. S.; Munoto; Hariadi, E.; Muslim, S.

    2018-04-01

    Artificial Intelligence Robot is a wheeled robot driven by a DC motor that moves along the wall using an ultrasonic sensor as a detector of obstacles. This study uses ultrasonic sensors HC-SR04 to measure the distance between the robot with the wall based ultrasonic wave. This robot uses Fuzzy Logic Controller to adjust the speed of DC motor. When the ultrasonic sensor detects a certain distance, sensor data is processed on ATmega8 then the data goes to ATmega16. From ATmega16, sensor data is calculated based on Fuzzy rules to drive DC motor speed. The program used to adjust the speed of a DC motor is CVAVR program (Code Vision AVR). The readable distance of ultrasonic sensor is 3 cm to 250 cm with response time 0.5 s. Testing of robots on walls with a setpoint value of 9 cm to 10 cm produce an average error value of -12% on the wall of L, -8% on T walls, -8% on U wall, and -1% in square wall.

  18. 40 CFR 268.9 - Special rules regarding wastes that exhibit a characteristic.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Special rules regarding wastes that... (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS General § 268.9 Special rules regarding wastes that exhibit a characteristic. (a) The initial generator of a solid waste must determine each EPA...

  19. Multicenter Cohort Study Comparing U.S. Management of Inpatient Pediatric Immune Thrombocytopenia to Current Treatment Guidelines.

    Science.gov (United States)

    Witmer, Char M; Lambert, Michele P; O'Brien, Sarah H; Neunert, Cindy

    2016-07-01

    Recent pediatric immune thrombocytopenia (ITP) guidelines have significantly altered and are encouraging an observational approach for patients without significant bleeding regardless of their platelet count. This retrospective multicenter cohort study utilized the Pediatric Health Information Systems (PHIS) administrative database. Subjects were 6 months to 18 years of age, admitted to a PHIS hospital between January 1, 2008 and September 30, 2014, with a primary diagnosis code for ITP. International Classification of Disease, Ninth Revision, Clinical Modification Code (ICD-9-CM) discharge codes identified significant bleeding. Pharmaceutical billing codes identified the use of pharmacologic therapy for ITP. Clinical management during preguideline admissions (January 1, 2008 to August 31, 2011) was compared to postguideline admissions (September 1, 2011 to September 30, 2014). A total of 4,937 subjects met inclusion criteria with a mean age of 6.2 (SD 5) years; 93.4% (4,613/4,937) received pharmacologic treatment for ITP but only 14.2% (699/4,937) had ICD-9-CM codes for significant bleeding; 11.5% (570/4,937) of subjects were readmitted. In comparing pre- versus postguideline time periods, the proportion of subjects receiving ITP pharmacologic treatment did not change (92.9% vs. 94.1%; P = 0.26). A decrease was found in the proportion of bone marrows performed (9.7% vs. 6.4%; P compared to 2008-2010 (12.9 vs. 14.5/10,000 PHIS admissions, P guidelines and evidence that supports a watchful waiting approach for pediatric patients with ITP, a large proportion of inpatients without significant bleeding are still receiving pharmacologic therapy. Continued efforts are needed to address why inpatient U.S. practice patterns are so discrepant from current treatment guidelines. © 2016 Wiley Periodicals, Inc.

  20. Inappropriate shocks in the subcutaneous ICD

    DEFF Research Database (Denmark)

    Olde Nordkamp, Louise R A; Brouwer, Tom F; Barr, Craig

    2015-01-01

    shocks have been reported. METHODS: We analyzed the incidence, predictors and management of inappropriate shocks in the EFFORTLESS S-ICD Registry, which collects S-ICD implantation information and follow-up data from clinical centers in Europe and New Zealand. RESULTS: During a follow-up of 21 ± 13...... xyphoid to V6) reduced the risk. Reprogramming or optimization of SVT treatment after the first clinical event of inappropriate shock was successful in preventing further inappropriate shocks for cardiac oversensing and SVT events. CONCLUSIONS: Inappropriate shocks, mainly due to cardiac oversensing...

  1. Validation of Case Finding Algorithms for Hepatocellular Cancer From Administrative Data and Electronic Health Records Using Natural Language Processing.

    Science.gov (United States)

    Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica

    2016-02-01

    Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC International Classification of Diseases, 9th Revision (ICD-9) codes, and evaluated whether natural language processing by the Automated Retrieval Console (ARC) for document classification improves HCC identification. We identified a cohort of patients with ICD-9 codes for HCC during 2005-2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared with manual classification. PPV, sensitivity, and specificity of ARC were calculated. A total of 1138 patients with HCC were identified by ICD-9 codes. On the basis of manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. A combined approach of ICD-9 codes and natural language processing of pathology and radiology reports improves HCC case identification in automated data.

  2. Proposals for Paraphilic Disorders in the International Classification of Diseases and Related Health Problems, Eleventh Revision (ICD-11).

    Science.gov (United States)

    Krueger, Richard B; Reed, Geoffrey M; First, Michael B; Marais, Adele; Kismodi, Eszter; Briken, Peer

    2017-07-01

    The World Health Organization is currently developing the 11th revision of the International Classifications of Diseases and Related Health Problems (ICD-11), with approval of the ICD-11 by the World Health Assembly anticipated in 2018. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH) was created and charged with reviewing and making recommendations for categories related to sexuality that are contained in the chapter of Mental and Behavioural Disorders in ICD-10 (World Health Organization 1992a). Among these categories was the ICD-10 grouping F65, Disorders of sexual preference, which describes conditions now widely referred to as Paraphilic Disorders. This article reviews the evidence base, rationale, and recommendations for the proposed revisions in this area for ICD-11 and compares them with DSM-5. The WGSDSH recommended that the grouping, Disorders of sexual preference, be renamed to Paraphilic Disorders and be limited to disorders that involve sexual arousal patterns that focus on non-consenting others or are associated with substantial distress or direct risk of injury or death. Consistent with this framework, the WGSDSH also recommended that the ICD-10 categories of Fetishism, Fetishistic Transvestism, and Sadomasochism be removed from the classification and new categories of Coercive Sexual Sadism Disorder, Frotteuristic Disorder, Other Paraphilic Disorder Involving Non-Consenting Individuals, and Other Paraphilic Disorder Involving Solitary Behaviour or Consenting Individuals be added. The WGSDSH's proposals for Paraphilic Disorders in ICD-11 are based on the WHO's role as a global public health agency and the ICD's function as a public health reporting tool.

  3. Coding in pigeons: Multiple-coding versus single-code/default strategies.

    Science.gov (United States)

    Pinto, Carlos; Machado, Armando

    2015-05-01

    To investigate the coding strategies that pigeons may use in a temporal discrimination tasks, pigeons were trained on a matching-to-sample procedure with three sample durations (2s, 6s and 18s) and two comparisons (red and green hues). One comparison was correct following 2-s samples and the other was correct following both 6-s and 18-s samples. Tests were then run to contrast the predictions of two hypotheses concerning the pigeons' coding strategies, the multiple-coding and the single-code/default. According to the multiple-coding hypothesis, three response rules are acquired, one for each sample. According to the single-code/default hypothesis, only two response rules are acquired, one for the 2-s sample and a "default" rule for any other duration. In retention interval tests, pigeons preferred the "default" key, a result predicted by the single-code/default hypothesis. In no-sample tests, pigeons preferred the key associated with the 2-s sample, a result predicted by multiple-coding. Finally, in generalization tests, when the sample duration equaled 3.5s, the geometric mean of 2s and 6s, pigeons preferred the key associated with the 6-s and 18-s samples, a result predicted by the single-code/default hypothesis. The pattern of results suggests the need for models that take into account multiple sources of stimulus control. © Society for the Experimental Analysis of Behavior.

  4. Validity and reliability of chronic tic disorder and obsessive-compulsive disorder diagnoses in the Swedish National Patient Register.

    Science.gov (United States)

    Rück, Christian; Larsson, K Johan; Lind, Kristina; Perez-Vigil, Ana; Isomura, Kayoko; Sariaslan, Amir; Lichtenstein, Paul; Mataix-Cols, David

    2015-06-22

    The usefulness of cases diagnosed in administrative registers for research purposes is dependent on diagnostic validity. This study aimed to investigate the validity and inter-rater reliability of recorded diagnoses of tic disorders and obsessive-compulsive disorder (OCD) in the Swedish National Patient Register (NPR). Chart review of randomly selected register cases and controls. 100 tic disorder cases and 100 OCD cases were randomly selected from the NPR based on codes from the International Classification of Diseases (ICD) 8th, 9th and 10th editions, together with 50 epilepsy and 50 depression control cases. The obtained psychiatric records were blindly assessed by 2 senior psychiatrists according to the criteria of the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) and ICD-10. Positive predictive value (PPV; cases diagnosed correctly divided by the sum of true positives and false positives). Between 1969 and 2009, the NPR included 7286 tic disorder and 24,757 OCD cases. The vast majority (91.3% of tic cases and 80.1% of OCD cases) are coded with the most recent ICD version (ICD-10). For tic disorders, the PPV was high across all ICD versions (PPV=89% in ICD-8, 86% in ICD-9 and 97% in ICD-10). For OCD, only ICD-10 codes had high validity (PPV=91-96%). None of the epilepsy or depression control cases were wrongly diagnosed as having tic disorders or OCD, respectively. Inter-rater reliability was outstanding for both tic disorders (κ=1) and OCD (κ=0.98). The validity and reliability of ICD codes for tic disorders and OCD in the Swedish NPR is generally high. We propose simple algorithms to further increase the confidence in the validity of these codes for epidemiological research. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Classifiers based on optimal decision rules

    KAUST Repository

    Amin, Talha

    2013-11-25

    Based on dynamic programming approach we design algorithms for sequential optimization of exact and approximate decision rules relative to the length and coverage [3, 4]. In this paper, we use optimal rules to construct classifiers, and study two questions: (i) which rules are better from the point of view of classification-exact or approximate; and (ii) which order of optimization gives better results of classifier work: length, length+coverage, coverage, or coverage+length. Experimental results show that, on average, classifiers based on exact rules are better than classifiers based on approximate rules, and sequential optimization (length+coverage or coverage+length) is better than the ordinary optimization (length or coverage).

  6. Classifiers based on optimal decision rules

    KAUST Repository

    Amin, Talha M.; Chikalov, Igor; Moshkov, Mikhail; Zielosko, Beata

    2013-01-01

    Based on dynamic programming approach we design algorithms for sequential optimization of exact and approximate decision rules relative to the length and coverage [3, 4]. In this paper, we use optimal rules to construct classifiers, and study two questions: (i) which rules are better from the point of view of classification-exact or approximate; and (ii) which order of optimization gives better results of classifier work: length, length+coverage, coverage, or coverage+length. Experimental results show that, on average, classifiers based on exact rules are better than classifiers based on approximate rules, and sequential optimization (length+coverage or coverage+length) is better than the ordinary optimization (length or coverage).

  7. The incidence of hip fractures in Norway -accuracy of the national Norwegian patient registry

    DEFF Research Database (Denmark)

    Høiberg, Mikkel; Gram, Jeppe; Hermann, Pernille

    2014-01-01

    % C.I. 8,934-9,249), excluding only 6.5% of all hip fractures defined by wider definitions. Conclusions: Based on current coding practice in Norway, a reliable national estimate of hip fracture incidences is found by a combination of relevant ICD-10 and NOMESCO codes in the NPR. This method may......Background: Hip fractures incur the greatest medical costs of any fracture. Valid epidemiological data are important to monitor for time-dependent changes. In Norway, hip fractures are registered in the Norwegian Patient Registry (NPR), but no published national validation exists. The aim...... of the present study was a national validation of NPR as a register for hip fractures using diagnostic codes (ICD-10 S 72.0-2) and/or procedure codes (NOMESCO version 1.14 NFBxy (x = 0-9, y = 0-2) or NFJxy (x = 0-9, y = 0-2). Method: A nationwide, population-based cohort comprising a random sub-sample of 1...

  8. Concordances and discrepancies between ICD-10 and DSM-IV criteria for anxiety disorders in childhood and adolescence

    Science.gov (United States)

    2012-01-01

    Background Mental disorders are classified by two major nosological systems, the ICD-10 and the DSM-IV-TR, consisting of different diagnostic criteria. The present study investigated the diagnostic concordance between the two systems for anxiety disorders in childhood and adolescence, in particular for separation anxiety disorder (SAD), specific phobia, social phobia, and generalized anxiety disorder (GAD). Methods A structured clinical interview, the Kinder-DIPS, was administered to 210 children and 258 parents. The percentage of agreement, kappa, and Yule’s Y coefficients were calculated for all diagnoses. Specific criteria causing discrepancies between the two classification systems were identified. Results DSM-IV-TR consistently classified more children than ICD-10 with an anxiety disorder, with a higher concordance between DSM-IV-TR and the ICD-10 child section (F9) than with the adult section (F4) of the ICD-10. This result was found for all four investigated anxiety disorders. The results revealed low to high levels of concordance and poor to good agreement between the classification systems, depending on the anxiety disorder. Conclusions The two classification systems identify different children with an anxiety disorder. However, it remains an open question, whether the research results can be generalized to clinical practice since DSM-IV-TR is mainly used in research while ICD-10 is widely established in clinical practice in Europe. Therefore, the population investigated by the DSM (research population) is not identical with the population examined using the ICD (clinical population). PMID:23267678

  9. Concordances and discrepancies between ICD-10 and DSM-IV criteria for anxiety disorders in childhood and adolescence

    Directory of Open Access Journals (Sweden)

    Adornetto Carmen

    2012-12-01

    Full Text Available Abstract Background Mental disorders are classified by two major nosological systems, the ICD-10 and the DSM-IV-TR, consisting of different diagnostic criteria. The present study investigated the diagnostic concordance between the two systems for anxiety disorders in childhood and adolescence, in particular for separation anxiety disorder (SAD, specific phobia, social phobia, and generalized anxiety disorder (GAD. Methods A structured clinical interview, the Kinder-DIPS, was administered to 210 children and 258 parents. The percentage of agreement, kappa, and Yule’s Y coefficients were calculated for all diagnoses. Specific criteria causing discrepancies between the two classification systems were identified. Results DSM-IV-TR consistently classified more children than ICD-10 with an anxiety disorder, with a higher concordance between DSM-IV-TR and the ICD-10 child section (F9 than with the adult section (F4 of the ICD-10. This result was found for all four investigated anxiety disorders. The results revealed low to high levels of concordance and poor to good agreement between the classification systems, depending on the anxiety disorder. Conclusions The two classification systems identify different children with an anxiety disorder. However, it remains an open question, whether the research results can be generalized to clinical practice since DSM-IV-TR is mainly used in research while ICD-10 is widely established in clinical practice in Europe. Therefore, the population investigated by the DSM (research population is not identical with the population examined using the ICD (clinical population.

  10. Accuracy of administrative data for identification of patients with infective endocarditis.

    Science.gov (United States)

    Tan, Charlie; Hansen, Mark; Cohen, Gideon; Boyle, Karl; Daneman, Nick; Adhikari, Neill K J

    2016-12-01

    Infective endocarditis is associated with high morbidity and mortality rates that have plateaued over recent decades. Research to improve outcomes for these patients is limited by the rarity of this condition. Therefore, we sought to validate administrative database codes for the diagnosis of infective endocarditis. We conducted a retrospective validation study of International Classification of Diseases (ICD-10-CM) codes for infective endocarditis against clinical Duke criteria (definite and probable) at a large acute care hospital between October 1, 2013 and June 30, 2015. To identify potential cases missed by ICD-10-CM codes, we also screened the hospital's valvular heart surgery database and the microbiology laboratory database (the latter for patients with bacteremia due to organisms commonly causing endocarditis). Using definite Duke criteria or probable criteria with clinical suspicion as the reference standard, the ICD-10-CM codes had a sensitivity (SN) of 0.90 (95% confidence interval (CI), 0.81-0.95), specificity (SP) of 1 (95% CI, 1-1), positive predictive value (PPV) of 0.78 (95% CI, 0.68-0.85) and negative predictive value (NPV) of 1 (95% CI, 1-1). Restricting the case definition to definite Duke criteria resulted in an increase in SN to 0.95 (95% CI, 0.86-0.99) and a decrease in PPV to 0.6 (95% CI, 0.49-0.69), with no change in specificity. ICD-10-CM codes can accurately identify patients with infective endocarditis, and so administrative databases offer a potential means to study this infection over large jurisdictions, and thereby improve the prediction, diagnosis, treatment and prevention of this rare but serious infection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. A method for modeling co-occurrence propensity of clinical codes with application to ICD-10-PCS auto-coding.

    Science.gov (United States)

    Subotin, Michael; Davis, Anthony R

    2016-09-01

    Natural language processing methods for medical auto-coding, or automatic generation of medical billing codes from electronic health records, generally assign each code independently of the others. They may thus assign codes for closely related procedures or diagnoses to the same document, even when they do not tend to occur together in practice, simply because the right choice can be difficult to infer from the clinical narrative. We propose a method that injects awareness of the propensities for code co-occurrence into this process. First, a model is trained to estimate the conditional probability that one code is assigned by a human coder, given than another code is known to have been assigned to the same document. Then, at runtime, an iterative algorithm is used to apply this model to the output of an existing statistical auto-coder to modify the confidence scores of the codes. We tested this method in combination with a primary auto-coder for International Statistical Classification of Diseases-10 procedure codes, achieving a 12% relative improvement in F-score over the primary auto-coder baseline. The proposed method can be used, with appropriate features, in combination with any auto-coder that generates codes with different levels of confidence. The promising results obtained for International Statistical Classification of Diseases-10 procedure codes suggest that the proposed method may have wider applications in auto-coding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Basis of the tubesheet heat exchanger design rules used in the French pressure vessel code

    International Nuclear Information System (INIS)

    Osweiller, F.

    1990-01-01

    For about 40 years most tubesheet heat exchangers have been designed according to the standards of TEMA. Partly due to their simplicity, these rules do not assure a safe heat-exchangers design in all cases. This is the main reason why new tubesheet design rules were developed in 1981 in France for the French pressure vessel code CODAP. For fixed tubesheet heat exchangers the new rules account for the elastic rotational restraint of the shell and channel at the outer edge of the tubesheet. For floating-head and U- tube exchangers an approach was selected with some modifications. In both cases the tubesheet is replaced by an equivalent solid plate with adequate effective elastic constants, and the tube bundle is simulated by an elastic foundation. The elastic restraint at the edge of the tubesheet due the shell and channel is accounted for in different ways in the two types of heat exchangers. The purpose of the paper is to present the main basis of these rules and to compare them to TEMA rules

  13. Population-based evaluation of a suggested anatomic and clinical classification of congenital heart defects based on the International Paediatric and Congenital Cardiac Code

    Directory of Open Access Journals (Sweden)

    Goffinet François

    2011-10-01

    Full Text Available Abstract Background Classification of the overall spectrum of congenital heart defects (CHD has always been challenging, in part because of the diversity of the cardiac phenotypes, but also because of the oft-complex associations. The purpose of our study was to establish a comprehensive and easy-to-use classification of CHD for clinical and epidemiological studies based on the long list of the International Paediatric and Congenital Cardiac Code (IPCCC. Methods We coded each individual malformation using six-digit codes from the long list of IPCCC. We then regrouped all lesions into 10 categories and 23 subcategories according to a multi-dimensional approach encompassing anatomic, diagnostic and therapeutic criteria. This anatomic and clinical classification of congenital heart disease (ACC-CHD was then applied to data acquired from a population-based cohort of patients with CHD in France, made up of 2867 cases (82% live births, 1.8% stillbirths and 16.2% pregnancy terminations. Results The majority of cases (79.5% could be identified with a single IPCCC code. The category "Heterotaxy, including isomerism and mirror-imagery" was the only one that typically required more than one code for identification of cases. The two largest categories were "ventricular septal defects" (52% and "anomalies of the outflow tracts and arterial valves" (20% of cases. Conclusion Our proposed classification is not new, but rather a regrouping of the known spectrum of CHD into a manageable number of categories based on anatomic and clinical criteria. The classification is designed to use the code numbers of the long list of IPCCC but can accommodate ICD-10 codes. Its exhaustiveness, simplicity, and anatomic basis make it useful for clinical and epidemiologic studies, including those aimed at assessment of risk factors and outcomes.

  14. A rule-based software test data generator

    Science.gov (United States)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  15. Using Rule-Based Computer Programming to Unify Communication Rules Research.

    Science.gov (United States)

    Sanford, David L.; Roach, J. W.

    This paper proposes the use of a rule-based computer programming language as a standard for the expression of rules, arguing that the adoption of a standard would enable researchers to communicate about rules in a consistent and significant way. Focusing on the formal equivalence of artificial intelligence (AI) programming to different types of…

  16. Medicare and Medicaid programs; CY 2015 Home Health Prospective Payment System rate update; Home Health Quality Reporting Requirements; and survey and enforcement requirements for home health agencies. Final rule.

    Science.gov (United States)

    2014-11-06

    This final rule updates Home Health Prospective Payment System (HH PPS) rates, including the national, standardized 60-day episode payment rates, the national per-visit rates, and the non-routine medical supply (NRS) conversion factor under the Medicare prospective payment system for home health agencies (HHAs), effective for episodes ending on or after January 1, 2015. As required by the Affordable Care Act, this rule implements the second year of the four-year phase-in of the rebasing adjustments to the HH PPS payment rates. This rule provides information on our efforts to monitor the potential impacts of the rebasing adjustments and the Affordable Care Act mandated face-to-face encounter requirement. This rule also implements: Changes to simplify the face-to-face encounter regulatory requirements; changes to the HH PPS case-mix weights; changes to the home health quality reporting program requirements; changes to simplify the therapy reassessment timeframes; a revision to the Speech-Language Pathology (SLP) personnel qualifications; minor technical regulations text changes; and limitations on the reviewability of the civil monetary penalty provisions. Finally, this rule also discusses Medicare coverage of insulin injections under the HH PPS, the delay in the implementation of the International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM), and a HH value-based purchasing (HH VBP) model.

  17. Artificial Intelligence Learning Semantics via External Resources for Classifying Diagnosis Codes in Discharge Notes.

    Science.gov (United States)

    Lin, Chin; Hsu, Chia-Jung; Lou, Yu-Sheng; Yeh, Shih-Jen; Lee, Chia-Cheng; Su, Sui-Lung; Chen, Hsiang-Cheng

    2017-11-06

    Automated disease code classification using free-text medical information is important for public health surveillance. However, traditional natural language processing (NLP) pipelines are limited, so we propose a method combining word embedding with a convolutional neural network (CNN). Our objective was to compare the performance of traditional pipelines (NLP plus supervised machine learning models) with that of word embedding combined with a CNN in conducting a classification task identifying International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM) diagnosis codes in discharge notes. We used 2 classification methods: (1) extracting from discharge notes some features (terms, n-gram phrases, and SNOMED CT categories) that we used to train a set of supervised machine learning models (support vector machine, random forests, and gradient boosting machine), and (2) building a feature matrix, by a pretrained word embedding model, that we used to train a CNN. We used these methods to identify the chapter-level ICD-10-CM diagnosis codes in a set of discharge notes. We conducted the evaluation using 103,390 discharge notes covering patients hospitalized from June 1, 2015 to January 31, 2017 in the Tri-Service General Hospital in Taipei, Taiwan. We used the receiver operating characteristic curve as an evaluation measure, and calculated the area under the curve (AUC) and F-measure as the global measure of effectiveness. In 5-fold cross-validation tests, our method had a higher testing accuracy (mean AUC 0.9696; mean F-measure 0.9086) than traditional NLP-based approaches (mean AUC range 0.8183-0.9571; mean F-measure range 0.5050-0.8739). A real-world simulation that split the training sample and the testing sample by date verified this result (mean AUC 0.9645; mean F-measure 0.9003 using the proposed method). Further analysis showed that the convolutional layers of the CNN effectively identified a large number of keywords and automatically

  18. Moral empiricism and the bias for act-based rules.

    Science.gov (United States)

    Ayars, Alisabeth; Nichols, Shaun

    2017-10-01

    Previous studies on rule learning show a bias in favor of act-based rules, which prohibit intentionally producing an outcome but not merely allowing the outcome. Nichols, Kumar, Lopez, Ayars, and Chan (2016) found that exposure to a single sample violation in which an agent intentionally causes the outcome was sufficient for participants to infer that the rule was act-based. One explanation is that people have an innate bias to think rules are act-based. We suggest an alternative empiricist account: since most rules that people learn are act-based, people form an overhypothesis (Goodman, 1955) that rules are typically act-based. We report three studies that indicate that people can use information about violations to form overhypotheses about rules. In study 1, participants learned either three "consequence-based" rules that prohibited allowing an outcome or three "act-based" rules that prohibiting producing the outcome; in a subsequent learning task, we found that participants who had learned three consequence-based rules were more likely to think that the new rule prohibited allowing an outcome. In study 2, we presented participants with either 1 consequence-based rule or 3 consequence-based rules, and we found that those exposed to 3 such rules were more likely to think that a new rule was also consequence based. Thus, in both studies, it seems that learning 3 consequence-based rules generates an overhypothesis to expect new rules to be consequence-based. In a final study, we used a more subtle manipulation. We exposed participants to examples act-based or accident-based (strict liability) laws and then had them learn a novel rule. We found that participants who were exposed to the accident-based laws were more likely to think a new rule was accident-based. The fact that participants' bias for act-based rules can be shaped by evidence from other rules supports the idea that the bias for act-based rules might be acquired as an overhypothesis from the

  19. Characterizing semantic mappings adaptation via biomedical KOS evolution: a case study investigating SNOMED CT and ICD.

    Science.gov (United States)

    Dos Reis, Julio Cesar; Pruski, Cédric; Da Silveira, Marcos; Reynaud-Delaître, Chantal

    2013-01-01

    Mappings established between Knowledge Organization Systems (KOS) increase semantic interoperability between biomedical information systems. However, biomedical knowledge is highly dynamic and changes affecting KOS entities can potentially invalidate part or the totality of existing mappings. Understanding how mappings evolve and what the impacts of KOS evolution on mappings are is therefore crucial for the definition of an automatic approach to maintain mappings valid and up-to-date over time. In this article, we study variations of a specific KOS complex change (split) for two biomedical KOS (SNOMED CT and ICD-9-CM) through a rigorous method of investigation for identifying and refining complex changes, and for selecting representative cases. We empirically analyze and explain their influence on the evolution of associated mappings. Results point out the importance of considering various dimensions of the information described in KOS, like the semantic structure of concepts, the set of relevant information used to define the mappings and the change operations interfering with this set of information.

  20. Reduction in depressive symptoms in primary prevention ICD scheduled patients - One year prospective study.

    Science.gov (United States)

    Amiaz, Revital; Asher, Elad; Rozen, Guy; Czerniak, Efrat; Levi, Linda; Weiser, Mark; Glikson, Michael

    2017-09-01

    Implantable Cardioverter Defibrillators (ICDs), have previously been associated with the onset of depression and anxiety. The aim of this one-year prospective study was to evaluate the rate of new onset psychopathological symptoms after elective ICD implantation. A total of 158 consecutive outpatients who were scheduled for an elective ICD implantation were diagnosed and screened based on the Mini International Neuropsychiatric Interview (MINI). Depression and anxiety were evaluated using the Hamilton Rating Scales for Depression (HAM-D) and Anxiety (HAM-A). Patient's attitude toward the ICD device was evaluated using a Visual Analog Scale (VAS). Patients' mean age was 64±12.4years; 134 (85%) were men, with the majority of patients performing the procedure for reasons of 'primary prevention'. According to the MINI diagnosis at baseline, three (2%) patients suffered from major depressive disorder and ten (6%) from dysthymia. Significant improvement in HAM-D mean scores was found between baseline, three months and one year after implantation (6.50±6.4; 4.10±5.3 and 2.7±4.6, respectively F(2100)=16.42; pdepressive symptoms, while the overall mindset toward the ICD device was positive and improved during the one-year follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Faber, M.H.; Sørensen, John Dalsgaard

    2003-01-01

    The present paper addresses fundamental concepts of reliability based code calibration. First basic principles of structural reliability theory are introduced and it is shown how the results of FORM based reliability analysis may be related to partial safety factors and characteristic values....... Thereafter the code calibration problem is presented in its principal decision theoretical form and it is discussed how acceptable levels of failure probability (or target reliabilities) may be established. Furthermore suggested values for acceptable annual failure probabilities are given for ultimate...... and serviceability limit states. Finally the paper describes the Joint Committee on Structural Safety (JCSS) recommended procedure - CodeCal - for the practical implementation of reliability based code calibration of LRFD based design codes....

  2. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples

    Science.gov (United States)

    Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask

    2015-01-01

    Background In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. Objectives and method The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. Results The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. Conclusions The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria. PMID:26450830

  3. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples

    Directory of Open Access Journals (Sweden)

    Maj Hansen

    2015-10-01

    Full Text Available Background: In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5, the symptom profile of posttraumatic stress disorder (PTSD was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11 that includes just six symptoms. Objectives and method: The objectives of the current study are: 1 to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746 using confirmatory factor analysis; 2 to assess the concurrent validity of the ICD-11 model of PTSD; and 3 to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. Results: The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. Conclusions: The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria.

  4. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples.

    Science.gov (United States)

    Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask

    2015-01-01

    In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria.

  5. Clashing Diagnostic Approaches: DSM-ICD versus RDoC

    Science.gov (United States)

    Lilienfeld, Scott O.; Treadway, Michael T.

    2016-01-01

    Since at least the middle of the past century, one overarching model of psychiatric classification, namely, that of the Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases (DSM-ICD), has reigned supreme. This DSM-ICD approach embraces an Aristotelian view of mental disorders as largely discrete entities that are characterized by distinctive signs, symptoms, and natural histories. Over the past several years, however, a competing vision, namely, the Research Domain Criteria (RDoC) initiative launched by the National Institute of Mental Health, has emerged in response to accumulating anomalies within the DSM-ICD system. In contrast to DSM-ICD, RDoC embraces a Galilean view of psychopathology as the product of dysfunctions in neural circuitry. RDoC appears to be a valuable endeavor that holds out the long-term promise of an alternative system of mental illness classification. We delineate three sets of pressing challenges – conceptual, methodological, and logistical/pragmatic – that must be addressed for RDoC to realize its scientific potential, and conclude with a call for further research, including investigation of a rapprochement between Aristotelian and Galilean approaches to psychiatric classification. PMID:26845519

  6. A C++ Class for Rule-Base Objects

    Directory of Open Access Journals (Sweden)

    William J. Grenney

    1992-01-01

    Full Text Available A C++ class, called Tripod, was created as a tool to assist with the development of rule-base decision support systems. The Tripod class contains data structures for the rule-base and member functions for operating on the data. The rule-base is defined by three ASCII files. These files are translated by a preprocessor into a single file that is located when a rule-base object is instantiated. The Tripod class was tested as part of a proto-type decision support system (DSS for winter highway maintenance in the Intermountain West. The DSS is composed of two principal modules: the main program, called the wrapper, and a Tripod rule-base object. The wrapper is a procedural module that interfaces with remote sensors and an external meterological database. The rule-base contains the logic for advising an inexperienced user and for assisting with the decision making process.

  7. Stereotyped movement disorder in ICD-11.

    Science.gov (United States)

    Stein, Dan J; Woods, Douglas W

    2014-01-01

    According to current proposals for ICD-11, stereotyped movement disorder will be classified in the grouping of neurodevelopmental disorders, with a qualifier to indicate whether self-injury is present, similar to the classification of stereotypic movement disorder in DSM-5. At the same time, the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders has proposed a grouping of body-focused repetitive behavior disorders within the obsessive-compulsive and related disorders (OCRD) cluster to include trichotillomania and skin-picking disorder. DSM-5 has taken a slightly different approach: trichotillomania and excoriation (skin picking) disorder are included in the OCRD grouping, while body-focused repetitive behavior disorder is listed under other specified forms of OCRD. DSM-5 also includes a separate category of nonsuicidal self-injury in the section on "conditions for further study." There are a number of unresolved nosological questions regarding the relationships among stereotyped movement disorder, body-focused repetitive behavior disorders, and nonsuicidal self-injury. In this article, we attempt to provide preliminary answers to some of these questions as they relate to the ICD-11 classification of mental and behavioral disorders.

  8. Evaluation of an ICD-10 algorithm to detect osteonecrosis of the jaw among cancer patients in the Danish National Registry of Patients

    DEFF Research Database (Denmark)

    Ehrenstein, Vera; Gammelager, Henrik; Schiødt, Morten

    2015-01-01

    recorded in 2005-2010 among cancer patients at the hospital Departments of Oral and Maxillofacial Surgery (DOMS) in three Danish regions, using a set of codes from the International Classification of Diseases, 10th revision (ICD-10). We abstracted DOMS charts of the potential cases, had the ONJ status...

  9. A 2.9 ps equivalent resolution interpolating time counter based on multiple independent coding lines

    International Nuclear Information System (INIS)

    Szplet, R; Jachna, Z; Kwiatkowski, P; Rozyc, K

    2013-01-01

    We present the design, operation and test results of a time counter that has an equivalent resolution of 2.9 ps, a measurement uncertainty at the level of 6 ps, and a measurement range of 10 s. The time counter has been implemented in a general-purpose reprogrammable device Spartan-6 (Xilinx). To obtain both high precision and wide measurement range the counting of periods of a reference clock is combined with a two-stage interpolation within a single period of the clock signal. The interpolation involves a four-phase clock in the first interpolation stage (FIS) and an equivalent coding line (ECL) in the second interpolation stage (SIS). The ECL is created as a compound of independent discrete time coding lines (TCL). The number of TCLs used to create the virtual ECL has an effect on its resolution. We tested ECLs made from up to 16 TCLs, but the idea may be extended to a larger number of lines. In the presented time counter the coarse resolution of the counting method equal to 2 ns (period of the 500 MHz reference clock) is firstly improved fourfold in the FIS and next even more than 400 times in the SIS. The proposed solution allows us to overcome the technological limitation in achievable resolution and improve the precision of conversion of integrated interpolators based on tapped delay lines. (paper)

  10. Estimation of Cachexia among Cancer Patients Based on Four Definitions

    Directory of Open Access Journals (Sweden)

    Kathleen M. Fox

    2009-01-01

    Full Text Available Objectives. Estimate and compare the proportion of cancer patients with cachexia using different definitions from available clinical data. Methods. Electronic medical records were examined to estimate the proportion of cancer patients with cachexia using 4 definitions: (1 ICD-9 diagnostic code of 799.4 (cachexia, (2 ICD-9 diagnosis of cachexia, anorexia, abnormal weight loss, or feeding difficulties, (3 prescription for megestrol acetate, oxandrolone, somatropin, or dronabinol, and (4 ≥5% weight loss. Patients with cancer of the stomach, pancreas, lung, colon/rectum, head/neck, esophagus, prostate, breast, or liver diagnosed between 1999 and 2004 were followed for cachexia. Results. Of 8541 cancer patients (60% men and 55% Caucasian, cachexia was observed in 2.4% of patients using the cachexia diagnostic code, 5.5% expanded diagnoses, 6.4% prescription medication definition, and 14.7% with ≥5% weight loss. Conclusions. The proportion of patients with cachexia varied considerably depending upon the definition employed, indicating that a standard operational definition is needed.

  11. 18 CFR 39.9 - Enforcement of Commission Rules and Orders.

    Science.gov (United States)

    2010-04-01

    ... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.9 Enforcement of Commission Rules and Orders. (a) The... or a Regional Entity to ensure compliance with a Reliability Standard or any Commission order...

  12. Development of a BWR loading pattern design system based on modified genetic algorithms and knowledge

    International Nuclear Information System (INIS)

    Martin-del-Campo, Cecilia; Francois, Juan Luis; Avendano, Linda; Gonzalez, Mario

    2004-01-01

    An optimization system based on Genetic Algorithms (GAs), in combination with expert knowledge coded in heuristics rules, was developed for the design of optimized boiling water reactor (BWR) fuel loading patterns. The system was coded in a computer program named Loading Pattern Optimization System based on Genetic Algorithms, in which the optimization code uses GAs to select candidate solutions, and the core simulator code CM-PRESTO to evaluate them. A multi-objective function was built to maximize the cycle energy length while satisfying power and reactivity constraints used as BWR design parameters. Heuristic rules were applied to satisfy standard fuel management recommendations as the Control Cell Core and Low Leakage loading strategies, and octant symmetry. To test the system performance, an optimized cycle was designed and compared against an actual operating cycle of Laguna Verde Nuclear Power Plant, Unit I

  13. Representation of ophthalmology concepts by electronic systems: adequacy of controlled medical terminologies.

    Science.gov (United States)

    Chiang, Michael F; Casper, Daniel S; Cimino, James J; Starren, Justin

    2005-02-01

    To assess the adequacy of 5 controlled medical terminologies (International Classification of Diseases 9, Clinical Modification [ICD9-CM]; Current Procedural Terminology 4 [CPT-4]; Systematized Nomenclature of Medicine, Clinical Terms [SNOMED-CT]; Logical Identifiers, Names, and Codes [LOINC]; Medical Entities Dictionary [MED]) for representing concepts in ophthalmology. Noncomparative case series. Twenty complete ophthalmology case presentations were sequentially selected from a publicly available ophthalmology journal. Each of the 20 cases was parsed into discrete concepts, and each concept was classified along 2 axes: (1) diagnosis, finding, or procedure and (2) ophthalmic or medical concept. Electronic or paper browsers were used to assign a code for every concept in each of the 5 terminologies. Adequacy of assignment for each concept was scored on a 3-point scale. Findings from all 20 case presentations were combined and compared based on a coverage score, which was the average score for all concepts in that terminology. Adequacy of assignment for concepts in each terminology, based on a 3-point Likert scale (0, no match; 1, partial match; 2, complete match). Cases were parsed into 1603 concepts. SNOMED-CT had the highest mean overall coverage score (1.625+/-0.667), followed by MED (0.974+/-0.764), LOINC (0.781+/-0.929), ICD9-CM (0.280+/-0.619), and CPT-4 (0.082+/-0.337). SNOMED-CT also had higher coverage scores than any of the other terminologies for concepts in the diagnosis, finding, and procedure categories. Average coverage scores for ophthalmic concepts were lower than those for medical concepts. Controlled terminologies are required for electronic representation of ophthalmology data. SNOMED-CT had significantly higher content coverage than any other terminology in this study.

  14. Inpatient Burden of Childhood Functional GI Disorders in the United States: An Analysis of National Trends in the U.S. from 1997 to 2009

    Science.gov (United States)

    Park, Richard; Mikami, Sage; LeClair, Jack; Bollom, Andrea; Lembo, Cara; Sethi, Saurabh; Lembo, Anthony; Jones, Mike; Cheng, Vivian; Friedlander, Elizabeth; Nurko, Samuel

    2017-01-01

    BACKGROUND Functional Gastrointestinal Disorders (FGIDs) are among the most common outpatient diagnoses in pediatric primary care and gastroenterology. There is limited data on the inpatient burden of childhood FGIDs in the U.S. The aim of this study was to evaluate the inpatient admission rate, length of stay, and associated costs related to FGIDs from 1997–2009. METHODS We analyzed the Kids’ Inpatient Sample Database (KID) for all subjects in which constipation (ICD-9 codes: 564.0–564.09), abdominal pain (ICD-9 codes: 789.0–789.09), irritable bowel syndrome (IBS) (ICD-9 code: 564.1), abdominal migraine (ICD-9 code:346.80 and 346.81)dyspepsia (ICD-9 code: 536.8) or fecal incontinence (ICD-codes: 787.6–787.63) was the primary discharge diagnosis from 1997–2009. The KID is the largest publicly available all-payer inpatient database in the U.S., containing data from 2–3 million pediatric hospital stays yearly. KEY RESULTS From 1997–2009, the number of discharges with a FGID primary diagnosis increased slightly from 6,348,537 to 6,393,803. The total mean cost per discharge increased significantly from $6115 to $18,058 despite the length of stay remaining relatively stable. Constipation and abdominal pain were the most common FGID discharge diagnoses. Abdominal pain and abdominal migraine discharges were most frequent in the 10–14 year age group. Constipation and fecal incontinence discharges were most frequent in the 5–9 year age group. IBS discharge was most common for the 15–17 year age group. CONCLUSIONS AND INFERENCES Hospitalizations and associated costs in childhood FGIDs have increased in number and cost in the U.S. from 1997–2009. Further studies to determine optimal methods to avoid unnecessary hospitalizations and potentially harmful diagnostic testing are indicated. PMID:25809794

  15. Inpatient burden of childhood functional GI disorders in the USA: an analysis of national trends in the USA from 1997 to 2009.

    Science.gov (United States)

    Park, R; Mikami, S; LeClair, J; Bollom, A; Lembo, C; Sethi, S; Lembo, A; Jones, M; Cheng, V; Friedlander, E; Nurko, S

    2015-05-01

    Functional gastrointestinal disorders (FGIDs) are among the most common outpatient diagnoses in pediatric primary care and gastroenterology. There is limited data on the inpatient burden of childhood FGIDs in the USA. The aim of this study was to evaluate the inpatient admission rate, length of stay (LoS), and associated costs related to FGIDs from 1997 to 2009. We analyzed the Kids' Inpatient Sample Database (KID) for all subjects in which constipation (ICD-9 codes: 564.0-564.09), abdominal pain (ICD-9 codes: 789.0-789.09), irritable bowel syndrome (IBS) (ICD-9 code: 564.1), abdominal migraine (ICD-9 code: 346.80 and 346.81) dyspepsia (ICD-9 code: 536.8), or fecal incontinence (ICD-codes: 787.6-787.63) was the primary discharge diagnosis from 1997 to 2009. The KID is the largest publicly available all-payer inpatient database in the USA, containing data from 2 to 3 million pediatric hospital stays yearly. From 1997 to 2009, the number of discharges with a FGID primary diagnosis increased slightly from 6,348,537 to 6,393,803. The total mean cost per discharge increased significantly from $6115 to $18,058 despite the LoS remaining relatively stable. Constipation and abdominal pain were the most common FGID discharge diagnoses. Abdominal pain and abdominal migraine discharges were most frequent in the 10-14 year age group. Constipation and fecal incontinence discharges were most frequent in the 5-9 year age group. IBS discharge was most common for the 15-17 year age group. Hospitalizations and associated costs in childhood FGIDs have increased in number and cost in the USA from 1997 to 2009. Further studies to determine optimal methods to avoid unnecessary hospitalizations and potentially harmful diagnostic testing are indicated. © 2015 John Wiley & Sons Ltd.

  16. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  17. Predictions of the spontaneous symmetry-breaking theory for visual code completeness and spatial scaling in single-cell learning rules.

    Science.gov (United States)

    Webber, C J

    2001-05-01

    This article shows analytically that single-cell learning rules that give rise to oriented and localized receptive fields, when their synaptic weights are randomly and independently initialized according to a plausible assumption of zero prior information, will generate visual codes that are invariant under two-dimensional translations, rotations, and scale magnifications, provided that the statistics of their training images are sufficiently invariant under these transformations. Such codes span different image locations, orientations, and size scales with equal economy. Thus, single-cell rules could account for the spatial scaling property of the cortical simple-cell code. This prediction is tested computationally by training with natural scenes; it is demonstrated that a single-cell learning rule can give rise to simple-cell receptive fields spanning the full range of orientations, image locations, and spatial frequencies (except at the extreme high and low frequencies at which the scale invariance of the statistics of digitally sampled images must ultimately break down, because of the image boundary and the finite pixel resolution). Thus, no constraint on completeness, or any other coupling between cells, is necessary to induce the visual code to span wide ranges of locations, orientations, and size scales. This prediction is made using the theory of spontaneous symmetry breaking, which we have previously shown can also explain the data-driven self-organization of a wide variety of transformation invariances in neurons' responses, such as the translation invariance of complex cell response.

  18. Hispanics/Latinos & Cardiovascular Disease: Statistical Fact Sheet

    Science.gov (United States)

    Statistical Fact Sheet 2013 Update Hispanics/Latinos & Cardiovascular Diseases Cardiovascular Disease (CVD) (ICD/10 codes I00-I99, Q20-Q28) (ICD/9 codes 390-459, 745-747)  Among Mexican-American adults age 20 ...

  19. Optimal, Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2002-01-01

    Reliability based code calibration is considered in this paper. It is described how the results of FORM based reliability analysis may be related to the partial safety factors and characteristic values. The code calibration problem is presented in a decision theoretical form and it is discussed how...... of reliability based code calibration of LRFD based design codes....

  20. A Constructivist Approach to Rule Bases

    NARCIS (Netherlands)

    Sileno, G.; Boer, A.; van Engers, T.; Loiseau, S.; Filipe, J.; Duval, B.; van den Herik, J.

    2015-01-01

    The paper presents a set of algorithms for the conversion of rule bases between priority-based and constraint-based representations. Inspired by research in precedential reasoning in law, such algorithms can be used for the analysis of a rule base, and for the study of the impact of the introduction

  1. Integrated Case Based and Rule Based Reasoning for Decision Support

    OpenAIRE

    Eshete, Azeb Bekele

    2009-01-01

    This project is a continuation of my specialization project which was focused on studying theoretical concepts related to case based reasoning method, rule based reasoning method and integration of them. The integration of rule-based and case-based reasoning methods has shown a substantial improvement with regards to performance over the individual methods. Verdande Technology As wants to try integrating the rule based reasoning method with an existing case based system. This project focu...

  2. The validity of using ICD-9 codes and pharmacy records to identify patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Lee Todd A

    2011-02-01

    Full Text Available Abstract Background Administrative data is often used to identify patients with chronic obstructive pulmonary disease (COPD, yet the validity of this approach is unclear. We sought to develop a predictive model utilizing administrative data to accurately identify patients with COPD. Methods Sequential logistic regression models were constructed using 9573 patients with postbronchodilator spirometry at two Veterans Affairs medical centers (2003-2007. COPD was defined as: 1 FEV1/FVC Results 4564 of 9573 patients (47.7% had an FEV1/FVC Conclusion Commonly used definitions of COPD in observational studies misclassify the majority of patients as having COPD. Using multiple diagnostic codes in combination with pharmacy data improves the ability to accurately identify patients with COPD.

  3. ICD-10 and the clinical features of depressions: data of the CIRCADIAN-I program

    Directory of Open Access Journals (Sweden)

    O V Serdyuk

    2011-01-01

    Full Text Available The data of the CIRCADIAN-I trial suggest that depressions are unsatisfactorily diagnosed in psychiatric practice. Thus, some of the ICD-10 diagnoses used to denote depressive states (dysthymia, cyclothymia are made extremely rarely. Only comparatively short-term and reversible vital depressions are considered to be preferred for the categories of affective disorders (F.30-F.33. Any clinical deviations from this clinical presentation (sensitive, anxiety symptoms, a prolonged course, and no well-defined seasonal and circadian rhythms of mood worsening are regarded as a guide for ruling out the diagnosis of affective disorder. At the same time depressive states are classified as schizophrenia, adjustment disorders, etc.

  4. 4-CM2 CuInGaSe2 based solar cells

    International Nuclear Information System (INIS)

    Devaney, W.E.; Stewart, J.M.; Chen, W.S.

    1990-01-01

    This paper reports that polycrystalline thin-film solar cells with the structure ZnO/CdZnS/CuInGaSe 2 have been fabricated with larger single cell areas than have been previously reported. A cell of area 4-cm 2 has been made with an Am1.5, 100 mW/cm 2 total area conversion efficiency of (11.1% 912.0% active area) and AMO conversion efficiency of 10.0% (10.9% active area). The CuInGaSe 2 layer had a gallium to indium ratio of 0.26:0.74 with a band gap of approximately 1.15 eV. The cells use an isolated tab design for the negative (grid) contact, demonstrating the ability to pattern the semiconductor layers. Such CuInGaSe 2 based cells may be suitable both for large area terrestrial applications and for single-junction space cell applications

  5. PERCEPTION ABOUT ICDS SERVICES IN A RURAL POPULATION OF LUCKNOW, UTTAR PRADESH

    Directory of Open Access Journals (Sweden)

    Vandana Pandey

    2013-09-01

    Full Text Available Objective: To assess the perception of mother/fathers about the Anganwadicentres in a rural block of Lucknow district. Study design:Cross-sectional study.Study site: Kakori Block of Lucknow district, UP.Study subjects:Mothers/fathers whose children were attending the Anganwadicentre to receive the ICDS scheme.Results: A total of 453 mothers/fathers were interviewed. Majority (86.8% belonged to Hindu community and scheduled caste (62.8%.More than half(63.8% of the respondents viewed that their children received cooked food item as one full glass measure (80 grams per day. About half (53.9% of the respondents viewed that their children consumed food items at the AWCs itself, while 24.2% viewed that children brought it partially at home. However, 21.9% of them viewed that they brought all the food items at home whatever they received.  About one third (33.8% of the respondents perceived that the purpose of enrolment at AWCs of their children was learning.Majority (81.9% of the respondents viewed that there were the benefits of AWC in the village.Conclusions: The ICDS scheme may be very attractive but beneficiaries do not realize its importance.  Proper and sufficient nutritional supplementation provided to beneficiaries may help children towards leading a nutritionally sound and healthy life and combat malnutrition.

  6. PERCEPTION ABOUT ICDS SERVICES IN A RURAL POPULATION OF LUCKNOW, UTTAR PRADESH

    Directory of Open Access Journals (Sweden)

    Vandana Pandey

    2013-12-01

    Full Text Available Objective: To assess the perception of mother/fathers about the Anganwadicentres in a rural block of Lucknow district. Study design:Cross-sectional study.Study site: Kakori Block of Lucknow district, UP.Study subjects:Mothers/fathers whose children were attending the Anganwadicentre to receive the ICDS scheme.Results: A total of 453 mothers/fathers were interviewed. Majority (86.8% belonged to Hindu community and scheduled caste (62.8%.More than half(63.8% of the respondents viewed that their children received cooked food item as one full glass measure (80 grams per day. About half (53.9% of the respondents viewed that their children consumed food items at the AWCs itself, while 24.2% viewed that children brought it partially at home. However, 21.9% of them viewed that they brought all the food items at home whatever they received.  About one third (33.8% of the respondents perceived that the purpose of enrolment at AWCs of their children was learning.Majority (81.9% of the respondents viewed that there were the benefits of AWC in the village.Conclusions: The ICDS scheme may be very attractive but beneficiaries do not realize its importance.  Proper and sufficient nutritional supplementation provided to beneficiaries may help children towards leading a nutritionally sound and healthy life and combat malnutrition.

  7. Emergency general surgery: definition and estimated burden of disease.

    Science.gov (United States)

    Shafi, Shahid; Aboutanos, Michel B; Agarwal, Suresh; Brown, Carlos V R; Crandall, Marie; Feliciano, David V; Guillamondegui, Oscar; Haider, Adil; Inaba, Kenji; Osler, Turner M; Ross, Steven; Rozycki, Grace S; Tominaga, Gail T

    2013-04-01

    Acute care surgery encompasses trauma, surgical critical care, and emergency general surgery (EGS). While the first two components are well defined, the scope of EGS practice remains unclear. This article describes the work of the American Association for the Surgery of Trauma to define EGS. A total of 621 unique International Classification of Diseases-9th Rev. (ICD-9) diagnosis codes were identified using billing data (calendar year 2011) from seven large academic medical centers that practice EGS. A modified Delphi methodology was used by the American Association for the Surgery of Trauma Committee on Severity Assessment and Patient Outcomes to review these codes and achieve consensus on the definition of primary EGS diagnosis codes. National Inpatient Sample data from 2009 were used to develop a national estimate of EGS burden of disease. Several unique ICD-9 codes were identified as primary EGS diagnoses. These encompass a wide spectrum of general surgery practice, including upper and lower gastrointestinal tract, hepatobiliary and pancreatic disease, soft tissue infections, and hernias. National Inpatient Sample estimates revealed over 4 million inpatient encounters nationally in 2009 for EGS diseases. This article provides the first list of ICD-9 diagnoses codes that define the scope of EGS based on current clinical practices. These findings have wide implications for EGS workforce training, access to care, and research.

  8. A combined paging alert and web-based instrument alters clinician behavior and shortens hospital length of stay in acute pancreatitis.

    Science.gov (United States)

    Dimagno, Matthew J; Wamsteker, Erik-Jan; Rizk, Rafat S; Spaete, Joshua P; Gupta, Suraj; Sahay, Tanya; Costanzo, Jeffrey; Inadomi, John M; Napolitano, Lena M; Hyzy, Robert C; Desmond, Jeff S

    2014-03-01

    There are many published clinical guidelines for acute pancreatitis (AP). Implementation of these recommendations is variable. We hypothesized that a clinical decision support (CDS) tool would change clinician behavior and shorten hospital length of stay (LOS). Observational study, entitled, The AP Early Response (TAPER) Project. Tertiary center emergency department (ED) and hospital. Two consecutive samplings of patients having ICD-9 code (577.0) for AP were generated from the emergency department (ED) or hospital admissions. Diagnosis of AP was based on conventional Atlanta criteria. The Pre-TAPER-CDS-Tool group (5/30/06-6/22/07) had 110 patients presenting to the ED with AP per 976 ICD-9 (577.0) codes and the Post-TAPER-CDS-Tool group (5/30/06-6/22/07) had 113 per 907 ICD-9 codes (7/14/10-5/5/11). The TAPER-CDS-Tool, developed 12/2008-7/14/2010, is a combined early, automated paging-alert system, which text pages ED clinicians about a patient with AP and an intuitive web-based point-of-care instrument, consisting of seven early management recommendations. The pre- vs. post-TAPER-CDS-Tool groups had similar baseline characteristics. The post-TAPER-CDS-Tool group met two management goals more frequently than the pre-TAPER-CDS-Tool group: risk stratification (P6L/1st 0-24 h (P=0.0003). Mean (s.d.) hospital LOS was significantly shorter in the post-TAPER-CDS-Tool group (4.6 (3.1) vs. 6.7 (7.0) days, P=0.0126). Multivariate analysis identified four independent variables for hospital LOS: the TAPER-CDS-Tool associated with shorter LOS (P=0.0049) and three variables associated with longer LOS: Japanese severity score (P=0.0361), persistent organ failure (P=0.0088), and local pancreatic complications (<0.0001). The TAPER-CDS-Tool is associated with changed clinician behavior and shortened hospital LOS, which has significant financial implications.

  9. Body-focused repetitive behavior disorders in ICD-11

    Directory of Open Access Journals (Sweden)

    Jon E. Grant

    2014-01-01

    Full Text Available This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  10. 9 CFR 202.111 - Rule 11: Hearing, oral or written.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Rule 11: Hearing, oral or written. 202.111 Section 202.111 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS... for oral hearing, timely filed. Declining to make such withdrawal shall not affect the rights or...

  11. 75 FR 55295 - List of Rules To Be Reviewed Pursuant to the Regulatory Flexibility Act

    Science.gov (United States)

    2010-09-10

    ... securities held or to be acquired by the fund. The rule requires 17j-1 organizations to adopt codes of ethics... liability for manipulation under Sections 9(a)(2) and 10(b) of the Exchange Act, and Rule 10b-5 thereunder...

  12. ICDE project report: collection and analysis of common-cause failure of check valves

    International Nuclear Information System (INIS)

    Theiss, Klaus; Hessel, Philippe; Werner, Wolfgang

    2003-05-01

    This report documents a study performed on the set of Common Cause Failure (CCF) events of Check Valves (CVs). The events studied here were derived from the International CCF Data Exchange (ICDE) database. Organizations from Canada, Finland, France, Germany, Netherlands, Sweden, Switzerland and the United States contributed with data to this data exchange. This study examines 94 CCF events of CVs reported in the ICDE database by tabulating the data and observing trends. The database contains general information about event attributes like root cause, coupling factor, detection method and corrective action taken. As part of this study, most of these events were reviewed in more detail and characterized by failure cause and failure symptom categories. The study itself begins with an overview of the entire data set in chapter 5. Charts are provided for each of the above-mentioned event attributes. This chapter forms the baseline for chapter 6. The intention of chapter 6 is to give the reader a deeper qualitative insight in the database content beyond that obtained from using the event coding only. Chapter 7 contains the summary of the study results and the conclusions derived from. Approximately 8% of all ICDE events of CVs were complete CCFs (all redundant components had failed). The number of partial CCF events (at least two of the redundant components failed) accounted for 24%. In the remaining 68% of the ICDE events, less than two components had failed completely, and the other components of the observed group only suffered from small defects, incipient degradation or were not affected at all. However, it was found that for more than 75% of the ICDE events the causal factors had a high probability to be shared by all the redundant components. 88 of the 94 reported ICDE events were reviewed in some more detail in Section 6 of this report with respect to failure causes, failure symptoms and failure mechanism. All events classified with a low 'shared cause factor

  13. 9Be(d,n)10B-based neutron sources for BNCT

    International Nuclear Information System (INIS)

    Capoulat, M.E.; Herrera, M.S.; Minsky, D.M.; González, S.J.; Kreiner, A.J.

    2014-01-01

    In the frame of accelerator-based BNCT, the 9 Be(d,n) 10 B reaction was investigated as a possible source of epithermal neutrons. In order to determine the configuration in terms of bombarding energy, target thickness and Beam Shaping Assembly (BSA) design that results in the best possible beam quality, a systematic optimization study was carried out. From this study, the optimal configuration resulted in tumor doses ≥40 Gy-Eq, with a maximum value of 51 Gy-Eq at a depth of about 2.7 cm, in a 60 min treatment. The optimal configuration was considered for the treatment planning assessment of a real Glioblastoma Multiforme case. From this, the resulted dose performances were comparable to those obtained with an optimized 7 Li(p,n)-based neutron source, under identical conditions and subjected to the same clinical protocol. - Highlights: • Study of the 9 Be(d,n) 10 B reaction as a source of epithermal neutrons for BNCT. • Evaluation of the optimal configuration of target thickness, deuteron energy and BSA design. • Computational dose assessment for brain tumor treatments using the MCNP code. • Treatment planning assessment of a particular clinical Glioblastoma Multiforme case. • Dose performances were comparable to those obtained with an optimized 7 Li(p,n)-based source

  14. Predicting opportunities to increase utilization of laparoscopy for colon cancer.

    Science.gov (United States)

    Keller, Deborah S; Parikh, Niraj; Senagore, Anthony J

    2017-04-01

    Despite proven safety and efficacy, rates of minimally invasive approaches for colon cancer remain low in the USA. Given the known benefits, investigating the root causes of underutilization and methods to increase laparoscopy is warranted. Our goal was to develop a predictive model of factors impacting use of laparoscopic surgery for colon cancer. The Premier Hospital Database was reviewed for elective colorectal resections for colon cancer (2009-2014). Patients were identified by ICD-9-CM diagnosis code and then stratified into open or laparoscopic approaches by ICD-9-CM procedure codes. An adjusted multivariate logistic regression model identified variables predictive of use of laparoscopy for colon cancer. A total of 24,245 patients were included-12,523 (52 %) laparoscopic and 11,722 (48 %) open. General surgeons performed the majority of all procedures (77.99 % open, 71.60 % laparoscopic). Overall use of laparoscopy increased from 48.94 to 52.03 % over the study period (p colon cancer laparoscopically. Colorectal surgeons were 32 % more likely to approach a case laparoscopically than general surgeons (OR 1.315, 95 % CI [1.222, 1.415], p characteristics that can be identified preoperatively to predict who will undergo surgery for colon cancer using laparoscopy. However, additional patients may be eligible for laparoscopy based on patient-level characteristics. These results have implications for regionalization and increasing teaching of MIS. Recognizing and addressing these variables with training and recruiting could increase use of minimally invasive approaches, with the associated clinical and financial benefits.

  15. 9 CFR 202.115 - Rule 15: Submission for final consideration.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Rule 15: Submission for final consideration. 202.115 Section 202.115 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS... the judicial officer for decision. (d) Oral argument. There shall be no right to oral argument other...

  16. A self-report measure for the ICD-11 dimensional trait model proposal: The personality inventory for ICD-11.

    Science.gov (United States)

    Oltmanns, Joshua R; Widiger, Thomas A

    2018-02-01

    Proposed for the 11th edition of the World Health Organization's International Classification of Diseases (ICD-11) is a dimensional trait model for the classification of personality disorder (Tyrer, Reed, & Crawford, 2015). The ICD-11 proposal consists of 5 broad domains: negative affective, detachment, dissocial, disinhibition, and anankastic (Mulder, Horwood, Tyrer, Carter, & Joyce, 2016). Several field trials have examined this proposal, yet none has included a direct measure of the trait model. The purpose of the current study was to develop and provide initial validation for the Personality Inventory for ICD-11 (PiCD), a self-report measure of this proposed 5-domain maladaptive trait model. Item selection and scale construction proceeded through 3 initial data collections assessing potential item performance. Two subsequent studies were conducted for scale validation. In Study 1, the PiCD was evaluated in a sample of 259 MTurk participants (who were or had been receiving mental health treatment) with respect to 2 measures of general personality structure: The Eysenck Personality Questionnaire-Revised and the 5-Dimensional Personality Test. In Study 2, the PiCD was evaluated in an additional sample of 285 participants with respect to 2 measures of maladaptive personality traits: The Personality Inventory for DSM-5 and the Computerized Adaptive Test for Personality Disorders. Study 3 provides an item-level exploratory structural equation model with the combined samples from Studies 1 and 2. The results are discussed with respect to the validity of the measure and the potential benefits for future research in having a direct, self-report measure of the ICD-11 trait proposal. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. Rule-based decision making model

    International Nuclear Information System (INIS)

    Sirola, Miki

    1998-01-01

    A rule-based decision making model is designed in G2 environment. A theoretical and methodological frame for the model is composed and motivated. The rule-based decision making model is based on object-oriented modelling, knowledge engineering and decision theory. The idea of safety objective tree is utilized. Advanced rule-based methodologies are applied. A general decision making model 'decision element' is constructed. The strategy planning of the decision element is based on e.g. value theory and utility theory. A hypothetical process model is built to give input data for the decision element. The basic principle of the object model in decision making is division in tasks. Probability models are used in characterizing component availabilities. Bayes' theorem is used to recalculate the probability figures when new information is got. The model includes simple learning features to save the solution path. A decision analytic interpretation is given to the decision making process. (author)

  18. Classifying aging as a disease in the context of ICD-11.

    Science.gov (United States)

    Zhavoronkov, Alex; Bhullar, Bhupinder

    2015-01-01

    Aging is a complex continuous multifactorial process leading to loss of function and crystalizing into the many age-related diseases. Here, we explore the arguments for classifying aging as a disease in the context of the upcoming World Health Organization's 11th International Statistical Classification of Diseases and Related Health Problems (ICD-11), expected to be finalized in 2018. We hypothesize that classifying aging as a disease with a "non-garbage" set of codes will result in new approaches and business models for addressing aging as a treatable condition, which will lead to both economic and healthcare benefits for all stakeholders. Actionable classification of aging as a disease may lead to more efficient allocation of resources by enabling funding bodies and other stakeholders to use quality-adjusted life years (QALYs) and healthy-years equivalent (HYE) as metrics when evaluating both research and clinical programs. We propose forming a Task Force to interface the WHO in order to develop a multidisciplinary framework for classifying aging as a disease with multiple disease codes facilitating for therapeutic interventions and preventative strategies.

  19. Patient satisfaction and suggestions for improvement of remote ICD monitoring

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe

    2012-01-01

    PURPOSE: The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients' wish for changes in remote follow-up routines. METHODS: Four hundred seventy-four ICD patients at the device follow-up c...

  20. Early esophagogastroduodenoscopy is associated with better Outcomes in upper gastrointestinal bleeding: a nationwide study

    Science.gov (United States)

    Garg, Sushil K.; Anugwom, Chimaobi; Campbell, James; Wadhwa, Vaibhav; Gupta, Nancy; Lopez, Rocio; Shergill, Sukhman; Sanaka, Madhusudhan R.

    2017-01-01

    Background and study aims We analyzed NIS (National Inpatient Sample) database from 2007 – 2013 to determine if early esophagogastroduodenoscopy (EGD) (24 hours) for upper gastrointestinal bleeding improved the outcomes in terms of mortality, length of stay and costs. Patients and methods Patients were classified as having upper gastrointestinal hemorrhage by querying all diagnostic codes for the ICD-9-CM codes corresponding to upper gastrointestinal bleeding. For these patients, performance of EGD during admission was determined by querying all procedural codes for the ICD-9-CM codes corresponding to EGD; early EGD was defined as having EGD performed within 24 hours of admission and late EGD was defined as having EGD performed after 24 hours of admission. Results A total of 1,789,532 subjects with UGIH were identified. Subjects who had an early EGD were less likely to have hypovolemia, acute renal failure and acute respiratory failure. On multivariable analysis, we found that subjects without EGD were 3 times more likely to die during the admission than those with early EGD. In addition, those with late EGD had 50 % higher odds of dying than those with an early EGD. Also, after adjusting for all factors in the model, hospital stay was on average 3 and 3.7 days longer for subjects with no or late EGD, respectively, then for subjects with early EGD. Conclusion Early EGD (within 24 hours) is associated with lower in-hospital mortality, morbidity, shorter length of stay and lower total hospital costs. PMID:28512647

  1. A Labor and Delivery Patient Classification System Based on Direct Nursing Care Time

    Science.gov (United States)

    1991-08-01

    equipment at bedside, position temperature probe or thermometer, assess respiratory rate, take pulse, place cuff around extremity, position stethoscope ...at bedside, assess respiratory rate, take pulse, place cuff around extremity, position stethoscope , measure blood pressure, remove cuff, record...International Classification of Diseases 9th Revision Clinical Modification (ICD-9-CM). A stratified random sample of the various types of delivery

  2. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    International Nuclear Information System (INIS)

    Akter, Jesmin; Takatori, Atsushi; Islam, Md. Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira

    2014-01-01

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas

  3. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Akter, Jesmin [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Islam, Md. Sazzadul [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakazawa, Atsuko [Department of Pathology, National Center for Child Health and Development, Tokyo (Japan); Ozaki, Toshinori, E-mail: tozaki@chiba-cc.jp [Laboratory of DNA Damage Signaling, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nagase, Hiroki [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakagawara, Akira [Saga Medical Centre, 840-8571 (Japan)

    2014-10-10

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  4. Female gender and acne disease are jointly and independently associated with the risk of major depression and suicide: a national population-based study.

    Science.gov (United States)

    Yang, Yi-Chien; Tu, Hung-Pin; Hong, Chien-Hui; Chang, Wei-Chao; Fu, Hung-Chun; Ho, Ji-Chen; Chang, Wei-Pin; Chuang, Hung-Yi; Lee, Chih-Hung

    2014-01-01

    Acne is a common disease in adolescence with female preponderance. It could cause poor self-esteem and social phobia. Previous studies based on questionnaires from several thousands of adolescents showed that acne is associated with major depression and suicide. However, the gender- and age-specific risk of depression and suicide in patients with acne remain largely unknown. Using a database from the National Health Insurance, which included 98% of the population of Taiwan in 2006, we identified patients of acne, major depression, and suicide based on ICD-9-CM codes. Totally 47111 patients with acne were identified (16568 males and 30543 females) from 1 million subjects. The youths of 7-12 years had the highest prevalence of acne (14.39%). Major depression was more common in those with acne (0.77%) than controls (0.56% , P suicide was noticed in women with acne. In conclusion, acne and gender, independently and jointly, are associated with major depression and suicide. Special medical support should be warranted in females with acne for the risk of major depression and suicide.

  5. Binary translation using peephole translation rules

    Science.gov (United States)

    Bansal, Sorav; Aiken, Alex

    2010-05-04

    An efficient binary translator uses peephole translation rules to directly translate executable code from one instruction set to another. In a preferred embodiment, the translation rules are generated using superoptimization techniques that enable the translator to automatically learn translation rules for translating code from the source to target instruction set architecture.

  6. Technical Note: FreeCT_ICD: An Open Source Implementation of a Model-Based Iterative Reconstruction Method using Coordinate Descent Optimization for CT Imaging Investigations.

    Science.gov (United States)

    Hoffman, John M; Noo, Frédéric; Young, Stefano; Hsieh, Scott S; McNitt-Gray, Michael

    2018-06-01

    To facilitate investigations into the impacts of acquisition and reconstruction parameters on quantitative imaging, radiomics and CAD using CT imaging, we previously released an open source implementation of a conventional weighted filtered backprojection reconstruction called FreeCT_wFBP. Our purpose was to extend that work by providing an open-source implementation of a model-based iterative reconstruction method using coordinate descent optimization, called FreeCT_ICD. Model-based iterative reconstruction offers the potential for substantial radiation dose reduction, but can impose substantial computational processing and storage requirements. FreeCT_ICD is an open source implementation of a model-based iterative reconstruction method that provides a reasonable tradeoff between these requirements. This was accomplished by adapting a previously proposed method that allows the system matrix to be stored with a reasonable memory requirement. The method amounts to describing the attenuation coefficient using rotating slices that follow the helical geometry. In the initially-proposed version, the rotating slices are themselves described using blobs. We have replaced this description by a unique model that relies on tri-linear interpolation together with the principles of Joseph's method. This model offers an improvement in memory requirement while still allowing highly accurate reconstruction for conventional CT geometries. The system matrix is stored column-wise and combined with an iterative coordinate descent (ICD) optimization. The result is FreeCT_ICD, which is a reconstruction program developed on the Linux platform using C++ libraries and the open source GNU GPL v2.0 license. The software is capable of reconstructing raw projection data of helical CT scans. In this work, the software has been described and evaluated by reconstructing datasets exported from a clinical scanner which consisted of an ACR accreditation phantom dataset and a clinical pediatric

  7. Validation of coding algorithms for the identification of patients hospitalized for alcoholic hepatitis using administrative data.

    Science.gov (United States)

    Pang, Jack X Q; Ross, Erin; Borman, Meredith A; Zimmer, Scott; Kaplan, Gilaad G; Heitman, Steven J; Swain, Mark G; Burak, Kelly W; Quan, Hude; Myers, Robert P

    2015-09-11

    Epidemiologic studies of alcoholic hepatitis (AH) have been hindered by the lack of a validated International Classification of Disease (ICD) coding algorithm for use with administrative data. Our objective was to validate coding algorithms for AH using a hospitalization database. The Hospital Discharge Abstract Database (DAD) was used to identify consecutive adults (≥18 years) hospitalized in the Calgary region with a diagnosis code for AH (ICD-10, K70.1) between 01/2008 and 08/2012. Medical records were reviewed to confirm the diagnosis of AH, defined as a history of heavy alcohol consumption, elevated AST and/or ALT (34 μmol/L, and elevated INR. Subgroup analyses were performed according to the diagnosis field in which the code was recorded (primary vs. secondary) and AH severity. Algorithms that incorporated ICD-10 codes for cirrhosis and its complications were also examined. Of 228 potential AH cases, 122 patients had confirmed AH, corresponding to a positive predictive value (PPV) of 54% (95% CI 47-60%). PPV improved when AH was the primary versus a secondary diagnosis (67% vs. 21%; P codes for ascites (PPV 75%; 95% CI 63-86%), cirrhosis (PPV 60%; 47-73%), and gastrointestinal hemorrhage (PPV 62%; 51-73%) had improved performance, however, the prevalence of these diagnoses in confirmed AH cases was low (29-39%). In conclusion the low PPV of the diagnosis code for AH suggests that caution is necessary if this hospitalization database is used in large-scale epidemiologic studies of this condition.

  8. Nine-year-old children use norm-based coding to visually represent facial expression.

    Science.gov (United States)

    Burton, Nichola; Jeffery, Linda; Skinner, Andrew L; Benton, Christopher P; Rhodes, Gillian

    2013-10-01

    Children are less skilled than adults at making judgments about facial expression. This could be because they have not yet developed adult-like mechanisms for visually representing faces. Adults are thought to represent faces in a multidimensional face-space, and have been shown to code the expression of a face relative to the norm or average face in face-space. Norm-based coding is economical and adaptive, and may be what makes adults more sensitive to facial expression than children. This study investigated the coding system that children use to represent facial expression. An adaptation aftereffect paradigm was used to test 24 adults and 18 children (9 years 2 months to 9 years 11 months old). Participants adapted to weak and strong antiexpressions. They then judged the expression of an average expression. Adaptation created aftereffects that made the test face look like the expression opposite that of the adaptor. Consistent with the predictions of norm-based but not exemplar-based coding, aftereffects were larger for strong than weak adaptors for both age groups. Results indicate that, like adults, children's coding of facial expressions is norm-based. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  9. A Navier-Strokes Chimera Code on the Connection Machine CM-5: Design and Performance

    Science.gov (United States)

    Jespersen, Dennis C.; Levit, Creon; Kwak, Dochan (Technical Monitor)

    1994-01-01

    We have implemented a three-dimensional compressible Navier-Stokes code on the Connection Machine CM-5. The code is set up for implicit time-stepping on single or multiple structured grids. For multiple grids and geometrically complex problems, we follow the 'chimera' approach, where flow data on one zone is interpolated onto another in the region of overlap. We will describe our design philosophy and give some timing results for the current code. A parallel machine like the CM-5 is well-suited for finite-difference methods on structured grids. The regular pattern of connections of a structured mesh maps well onto the architecture of the machine. So the first design choice, finite differences on a structured mesh, is natural. We use centered differences in space, with added artificial dissipation terms. When numerically solving the Navier-Stokes equations, there are liable to be some mesh cells near a solid body that are small in at least one direction. This mesh cell geometry can impose a very severe CFL (Courant-Friedrichs-Lewy) condition on the time step for explicit time-stepping methods. Thus, though explicit time-stepping is well-suited to the architecture of the machine, we have adopted implicit time-stepping. We have further taken the approximate factorization approach. This creates the need to solve large banded linear systems and creates the first possible barrier to an efficient algorithm. To overcome this first possible barrier we have considered two options. The first is just to solve the banded linear systems with data spread over the whole machine, using whatever fast method is available. This option is adequate for solving scalar tridiagonal systems, but for scalar pentadiagonal or block tridiagonal systems it is somewhat slower than desired. The second option is to 'transpose' the flow and geometry variables as part of the time-stepping process: Start with x-lines of data in-processor. Form explicit terms in x, then transpose so y-lines of data are

  10. Search for the sources of the solar wind in the 9.1 cm brightness temperature

    International Nuclear Information System (INIS)

    George, R.G.

    1975-01-01

    The sources of solar wind streams have been the object of intensive research for many years, but the various ideas of where and how streams originate on the sun are still incomplete and contradictory. The present study is an attempt to find the solar wind sources by mathematically approximating the 9.1 cm brightness temperature which would be expected at the foot of spacecraft-measured solar wind streams and by then comparing it with actual radio brightness temperature measurements. Several significant results were found from an analysis of the correlation results. Most plasma emanating from the sun was found to come from high solar latitudes and to deviate significantly from the normally expected east-west path in the low corona. Magnetic channelng causes correlation studies to fail when the sun's magnetic configuration is unstable. The travel time of the plasma from the sun's 9.1 cm emission level to the earth is often more than a month

  11. Fast-neutron, coded-aperture imager

    Science.gov (United States)

    Woolf, Richard S.; Phlips, Bernard F.; Hutcheson, Anthony L.; Wulf, Eric A.

    2015-06-01

    This work discusses a large-scale, coded-aperture imager for fast neutrons, building off a proof-of concept instrument developed at the U.S. Naval Research Laboratory (NRL). The Space Science Division at the NRL has a heritage of developing large-scale, mobile systems, using coded-aperture imaging, for long-range γ-ray detection and localization. The fast-neutron, coded-aperture imaging instrument, designed for a mobile unit (20 ft. ISO container), consists of a 32-element array of 15 cm×15 cm×15 cm liquid scintillation detectors (EJ-309) mounted behind a 12×12 pseudorandom coded aperture. The elements of the aperture are composed of 15 cm×15 cm×10 cm blocks of high-density polyethylene (HDPE). The arrangement of the aperture elements produces a shadow pattern on the detector array behind the mask. By measuring of the number of neutron counts per masked and unmasked detector, and with knowledge of the mask pattern, a source image can be deconvolved to obtain a 2-d location. The number of neutrons per detector was obtained by processing the fast signal from each PMT in flash digitizing electronics. Digital pulse shape discrimination (PSD) was performed to filter out the fast-neutron signal from the γ background. The prototype instrument was tested at an indoor facility at the NRL with a 1.8-μCi and 13-μCi 252Cf neutron/γ source at three standoff distances of 9, 15 and 26 m (maximum allowed in the facility) over a 15-min integration time. The imaging and detection capabilities of the instrument were tested by moving the source in half- and one-pixel increments across the image plane. We show a representative sample of the results obtained at one-pixel increments for a standoff distance of 9 m. The 1.8-μCi source was not detected at the 26-m standoff. In order to increase the sensitivity of the instrument, we reduced the fastneutron background by shielding the top, sides and back of the detector array with 10-cm-thick HDPE. This shielding configuration led

  12. Deriving ICD-11 personality disorder domains from dsm-5 traits

    DEFF Research Database (Denmark)

    Bach, B; Sellbom, M; Kongerslev, M

    2017-01-01

    OBJECTIVE: The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. METHOD: We...... replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. RESULTS: Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized......-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix....

  13. Acromegaly according to the Danish National Registry of Patients: how valid are ICD diagnoses and how do patterns of registration affect the accuracy of registry data?

    Directory of Open Access Journals (Sweden)

    Dal J

    2014-09-01

    Full Text Available Jakob Dal,1 Nikolaj Skou,1 Eigil Husted Nielsen,2 Jens Otto Lunde Jørgensen,1 Lars Pedersen3 1Department of Endocrinology, Aarhus University Hospital, Aarhus, 2Department of Endocrinology, Aalborg University Hospital, Aalborg, 3Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark Background: The incidence of acromegaly is uncertain, since population-based studies are few. In the absence of a specific acromegaly registry, the Danish National Registry of Patients (DNRP becomes a potential source of data for studying the epidemiology of acromegaly, by linking all hospital discharge diagnoses to the personal identification numbers of individual Danish inhabitants. The validity of the DNRP with respect to acromegaly, however, remains to be tested. The aim of this study was to validate the International Classification of Diseases (ICD codes for acromegaly (ICD-8: 25300, 25301. ICD-10: E22.0 as used in the DNRP, and to assess the influence of various registration patterns on the accuracy of registry data. Methods: We identified patients registered with ICD codes for the diagnosis of acromegaly or other pituitary disorders during the period 1991–2009. Data on the institutional origin of each registration and the number of relevant DNRP registrations were recorded, and systematic patient chart reviews were performed to confirm the diagnosis. Results: In total, 110 cases of acromegaly were confirmed, compared with 275 registered cases, yielding a positive predictive value (PPV of 40%. When restricting the search to the regional highly specialized department of endocrinology, the PPV increased to 53% with no loss of cases with confirmed acromegaly. With a requirement of at least one, two, or three DNRP registrations, the PPV increased, but with a concurrent loss of confirmed cases. Conclusion: The DNRP seems to be a useful source for identifying new cases of acromegaly, especially when restricting the search to a relevant

  14. DSM-5 and ICD-11 as competing models of PTSD in preadolescent children exposed to a natural disaster: assessing validity and co-occurring symptomatology.

    Science.gov (United States)

    La Greca, Annette M; Danzi, BreAnne A; Chan, Sherilynn F

    2017-01-01

    Background : Major revisions have been made to the DSM and ICD models of post-traumatic stress disorder (PTSD). However, it is not known whether these models fit children's post-trauma responses, even though children are a vulnerable population following disasters. Objective : Using data from Hurricane Ike, we examined how well trauma-exposed children's symptoms fit the DSM-IV, DSM-5 and ICD-11 models, and whether the models varied by gender. We also evaluated whether elevated symptoms of depression and anxiety characterized children meeting PTSD criteria based on DSM-5 and ICD-11. Method : Eight-months post-disaster, children ( N  = 327, 7-11 years) affected by Hurricane Ike completed measures of PTSD, anxiety and depression. Algorithms approximated a PTSD diagnosis based on DSM-5 and ICD-11 models. Results : Using confirmatory factor analysis, ICD-11 had the best-fitting model, followed by DSM-IV and DSM-5. The ICD-11 model also demonstrated strong measurement invariance across gender. Analyses revealed poor overlap between DSM-5 and ICD-11, although children meeting either set of criteria reported severe PTSD symptoms. Further, children who met PTSD criteria for DSM-5, but not for ICD-11, reported significantly higher levels of depression and general anxiety than children not meeting DSM-5 criteria. Conclusions : Findings support the parsimonious ICD-11 model of PTSD for trauma-exposed children, although adequate fit also was obtained for DSM-5. Use of only one model of PTSD, be it DSM-5 or ICD-11, will likely miss children with significant post-traumatic stress. DSM-5 may identify children with high levels of comorbid symptomatology, which may require additional clinical intervention.

  15. A proposal for a standard communication protocol for pacemaker/ICD programmers

    NARCIS (Netherlands)

    Dijk, WA; Hooijschuur, CAM; van der Velde, W; Dassen, WRM

    2005-01-01

    The information generated by pacemakers and ICD's to support the cardiologist and technician for installing the optimal settings for the patient is increasing rapidly. In this paper a proposal is described for electronic data exchange between the pacemaker/ICD programmers and electronic information

  16. Anxiety Predicts Mortality in ICD Patients

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Caspar Thygesen, Lau; Hastrup Svendsen, Jesper

    2014-01-01

    BACKGROUND: Although highly effective in preventing arrhythmic death, patients receiving an implantable cardioverter defibrillator (ICD) may still experience psychological difficulties such as anxiety, depression, and reduced quality of life. The objectives of this study were to describe patient...... receiving ICD between January 1, 2011 and June 30, 2011 (n = 499). The following instruments were used: SF-36, Hospital Anxiety and Depression Scale, HeartQoL, EQ-5D, and the Multidimensional Fatigue Inventory. RESULTS: The response rate was 72%. Mean age was 65.5 years and 82% patients were males. Fifty...... of perceived health, quality of life, and fatigue; for example, physical health 39.8 versus 44.3 points, compared to secondary prevention indication. Anxiety, poor perceived health, fatigue, and low quality of life were all predictors of mortality, anxiety being the strongest with an adjusted odds ratio of 4...

  17. Challenges for Rule Systems on the Web

    Science.gov (United States)

    Hu, Yuh-Jong; Yeh, Ching-Long; Laun, Wolfgang

    The RuleML Challenge started in 2007 with the objective of inspiring the issues of implementation for management, integration, interoperation and interchange of rules in an open distributed environment, such as the Web. Rules are usually classified as three types: deductive rules, normative rules, and reactive rules. The reactive rules are further classified as ECA rules and production rules. The study of combination rule and ontology is traced back to an earlier active rule system for relational and object-oriented (OO) databases. Recently, this issue has become one of the most important research problems in the Semantic Web. Once we consider a computer executable policy as a declarative set of rules and ontologies that guides the behavior of entities within a system, we have a flexible way to implement real world policies without rewriting the computer code, as we did before. Fortunately, we have de facto rule markup languages, such as RuleML or RIF to achieve the portability and interchange of rules for different rule systems. Otherwise, executing real-life rule-based applications on the Web is almost impossible. Several commercial or open source rule engines are available for the rule-based applications. However, we still need a standard rule language and benchmark for not only to compare the rule systems but also to measure the progress in the field. Finally, a number of real-life rule-based use cases will be investigated to demonstrate the applicability of current rule systems on the Web.

  18. 9 CFR 355.43 - Scope and applicability of rules of practice.

    Science.gov (United States)

    2010-01-01

    ... AND VOLUNTARY INSPECTION AND CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Scope and applicability of rules of practice. 355.43 Section 355.43 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT...

  19. Scholars’ open debate paper on the World Health Organization ICD-11 Gaming Disorder proposal

    DEFF Research Database (Denmark)

    Aarseth, Espen; Bean, Anthony; Nielsen, Rune Kristian Lundedal

    2016-01-01

    main concerns are the low quality of the research base, the fact that the current operationalization leans too heavily on substance use and gambling criteria, and the lack of consensus on symptomatology and assessment of problematic gaming. The act of formalizing this disorder, even as a proposal, has...... Disorder as a diagnosis in ICD-11 will cause significant stigma to the millions of children who play video games as a part of a normal, healthy life. At this point, suggesting formal diagnoses and categories is premature: the ICD-11 proposal for Gaming Disorder should be removed to avoid a waste of public...

  20. Minding the body: Situating gender identity diagnoses in the ICD-11

    NARCIS (Netherlands)

    Drescher, J.; Cohen-Kettenis, P.T.; Winter, S.

    2012-01-01

    The World Health Organization (WHO) is in the process of revising the International Statistical Classification of Diseases and Related Health Problems (ICD) and ICD-11 has an anticipated publication date of 2015. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH)

  1. Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Casavant, David; Betzold, Robert; Sheldon, Todd; Tang, Feng; Mueller, Megan; Lingle, John

    2005-08-01

    Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.

  2. The data quality of splenomegaly ICD-10 diagnoses in a population-based hospital discharge registry

    DEFF Research Database (Denmark)

    Rotbain, E. C.; Lund Hansen, Dennis; Frederiksen, H.

    2015-01-01

    of our knowledge, accurate data on the risk of hematological malignancies, hepatic diseases and storage diseases among patients with splenomegaly have never been reported. The aim of this pilot study is to investigate the validity of the splenomegaly ICD-10 diagnoses, in order to ascertain...

  3. Medical Surveillance Monthly Report (MSMR). Volume 19, Number 1, January 2012

    Science.gov (United States)

    2012-01-01

    conditions (ICD-9-CM: 287), or malaria complicating pregnancy (ICD- 9-CM: 647.4) in any diagnostic position; or (5) a hospitalization record with a non...variability of estimates of case counts of malaria in relation to characteristics of sur- veillance case defi nitions. In particular, the report...subsequent diagnostic positions (with no malaria -specifi c or associated diagno- ses in the primary diagnostic position); ii) records of malaria - related

  4. Horizontal and Vertical Rule Bases Method in Fuzzy Controllers

    OpenAIRE

    Aminifar, Sadegh; bin Marzuki, Arjuna

    2013-01-01

    Concept of horizontal and vertical rule bases is introduced. Using this method enables the designers to look for main behaviors of system and describes them with greater approximations. The rules which describe the system in first stage are called horizontal rule base. In the second stage, the designer modulates the obtained surface by describing needed changes on first surface for handling real behaviors of system. The rules used in the second stage are called vertical rule base. Horizontal...

  5. Eu9Cd4-xCM2+x-y□ySb9: Ca9Mn4Bi9-type structure stuffed with coinage metals (Cu, Ag, and Au) and the challenges with classical valence theory in describing these possible zintl phases.

    Science.gov (United States)

    Kazem, Nasrin; Hurtado, Antonio; Klobes, Benedikt; Hermann, Raphaël P; Kauzlarich, Susan M

    2015-02-02

    The synthesis, crystal structure, magnetic properties, and europium Mössbauer spectroscopy of the new members of the 9-4-9 Zintl family of Eu(9)Cd(4-x)CM(2+x-y)□(y)Sb(9) (CM = coinage metal: Au, Ag, and Cu) are reported. These compounds crystallize in the Ca(9)Mn(4)Bi(9) structure type (9-4-9) with the 4g interstitial site almost half-occupied by coinage metals; these are the first members in the 9-4-9 family where the interstitial positions are occupied by a monovalent metal. All previously known compounds with this structure type include divalent interstitials where these interstitials are typically the same as the transition metals in the anionic framework. Single-crystal magnetic susceptibility data indicate paramagnetic behavior for all three compounds with antiferromagnetic ordering below 10 K (at 100 Oe) that shifts to lower temperature (x)CM(2+x-y)□(y)Sb(9) at 50 and 6.5 K in order to evaluate the valence of Eu cations. Although the Zintl formalism states that the five crystallographically distinct Eu sites in Eu(9)Cd(4-x)CM(2+x-y)□(y)Sb9 should bear Eu(2+), the Mössbauer spectral isomer shifts are clearly indicative of both 2+ and 3+ valence of the Eu cations with the Cu- and Au-containing compounds showing higher amounts of Eu(3+). This electronic configuration leads to an excess of negative charge in these compounds that contradicts the expected valence-precise requirement of Zintl phases. The spectra obtained at 6.5 K reveal magnetic ordering for both Eu(2+) and Eu(3+). The field dependence of Eu(2+) indicates two distinct magnetic sublattices, with higher and lower fields, and of a small field for Eu(3+). The site symmetry of the five Eu sites is not distinguishable from the Mössbauer data.

  6. Rule based systems for big data a machine learning approach

    CERN Document Server

    Liu, Han; Cocea, Mihaela

    2016-01-01

    The ideas introduced in this book explore the relationships among rule based systems, machine learning and big data. Rule based systems are seen as a special type of expert systems, which can be built by using expert knowledge or learning from real data. The book focuses on the development and evaluation of rule based systems in terms of accuracy, efficiency and interpretability. In particular, a unified framework for building rule based systems, which consists of the operations of rule generation, rule simplification and rule representation, is presented. Each of these operations is detailed using specific methods or techniques. In addition, this book also presents some ensemble learning frameworks for building ensemble rule based systems.

  7. 9 CFR 201.4 - Bylaws, rules and regulations, and requirements of exchanges, associations, or other...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Bylaws, rules and regulations, and... 201.4 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS ADMINISTRATION (PACKERS AND... of any exchange, association, or other organization, or any other valid law, rule or regulation, or...

  8. Minor Crashes and ‘Whiplash’ in the United States

    Science.gov (United States)

    Bartsch, Adam J.; Gilbertson, Lars G.; Prakash, Vikas; Morr, Douglas R.; Wiechel, John F.

    2008-01-01

    In the United States there is currently a paucity of available real world minor rear crash data with struck vehicle delta-V, or speed change, less than or equal to 15 kilometers per hour. These data are essential as researchers attempt to define ‘whiplash’ injury risk potential in these minor crashes. This study analyzed a new set of 105 U.S. minor rear aligned crashes between passenger vehicles. Mean struck vehicle delta-V and acceleration were 6.3 km/h (s.d. = 2.1 km/h) and 1.4g (s.d. = 0.5g), respectively. A total of 113 struck vehicle occupants were diagnosed within five weeks post-crash with 761 ICD-9-CM complaints and 427 AIS injuries (99.5% AIS1) attributed to the crashes. No striking vehicle occupants reported complaints. The main ICD-9-CM diagnoses were 40.6% cervical, 22.5% lumbar/sacral and 10.2% thoracic and the main AIS1 diagnoses were 29.7% cervical, 23.2% lumbar/sacral and 14.3% thoracic. The diagnosis disparity was mainly due to coding for pre-existing degenerative diagnosis in ICD-9-CM. Degenerative spine conditions were not significant for increased AIS1 injury risk. Surprisingly, many non-‘whiplash’ diagnoses were found. The AIS injury diagnosis distribution and frequency in these minor delta-V crashes did not correspond with previous minor rear crash studies. A prospectively collected and unbiased minor rear crash databank in the model of CIREN or NASS is highly desirable to verify or refute these results for the U.S. population since the current study cohort may have been influenced by litigation. PMID:19026229

  9. Minor crashes and 'whiplash' in the United States.

    Science.gov (United States)

    Bartsch, Adam J; Gilbertson, Lars G; Prakash, Vikas; Morr, Douglas R; Wiechel, John F

    2008-10-01

    In the United States there is currently a paucity of available real world minor rear crash data with struck vehicle delta-V, or speed change, less than or equal to 15 kilometers per hour. These data are essential as researchers attempt to define 'whiplash' injury risk potential in these minor crashes. This study analyzed a new set of 105 U.S. minor rear aligned crashes between passenger vehicles. Mean struck vehicle delta-V and acceleration were 6.3 km/h (s.d. = 2.1 km/h) and 1.4 g (s.d. = 0.5 g), respectively. A total of 113 struck vehicle occupants were diagnosed within five weeks post-crash with 761 ICD-9-CM complaints and 427 AIS injuries (99.5% AIS1) attributed to the crashes. No striking vehicle occupants reported complaints. The main ICD-9-CM diagnoses were 40.6% cervical, 22.5% lumbar/sacral and 10.2% thoracic and the main AIS1 diagnoses were 29.7% cervical, 23.2% lumbar/sacral and 14.3% thoracic. The diagnosis disparity was mainly due to coding for pre-existing degenerative diagnosis in ICD-9-CM. Degenerative spine conditions were not significant for increased AIS1 injury risk. Surprisingly, many non-'whiplash' diagnoses were found. The AIS injury diagnosis distribution and frequency in these minor delta-V crashes did not correspond with previous minor rear crash studies. A prospectively collected and unbiased minor rear crash databank in the model of CIREN or NASS is highly desirable to verify or refute these results for the U.S. population since the current study cohort may have been influenced by litigation.

  10. 77 FR 67724 - Rescission of Social Security Acquiescence Ruling 05-1(9)

    Science.gov (United States)

    2012-11-13

    ...-1213 or TTY 1-800-325-0778, or visit our Internet site, Social Security Online, at http://www... SOCIAL SECURITY ADMINISTRATION [Docket No. SSA-2012-0058] Rescission of Social Security Acquiescence Ruling 05-1(9) AGENCY: Social Security Administration. [[Page 67725

  11. 33 CFR 89.25 - Waters upon which Inland Rules 9(a)(ii), 14(d), and 15(b) apply.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Waters upon which Inland Rules 9(a)(ii), 14(d), and 15(b) apply. 89.25 Section 89.25 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES INLAND NAVIGATION RULES: IMPLEMENTING RULES Waters...

  12. Comparison of the costs of nonoperative care to minimally invasive surgery for sacroiliac joint disruption and degenerative sacroiliitis in a United States Medicare population: potential economic implications of a new minimally-invasive technology

    Science.gov (United States)

    Ackerman, Stacey J; Polly, David W; Knight, Tyler; Schneider, Karen; Holt, Tim; Cummings, John

    2013-01-01

    Introduction The economic burden associated with the treatment of low back pain (LBP) in the United States is significant. LBP caused by sacroiliac (SI) joint disruption/degenerative sacroiliitis is most commonly treated with nonoperative care and/or open SI joint surgery. New and effective minimally invasive surgery (MIS) options may offer potential cost savings to Medicare. Methods An economic model was developed to compare the costs of MIS treatment to nonoperative care for the treatment of SI joint disruption in the hospital inpatient setting in the US Medicare population. Lifetime cost savings (2012 US dollars) were estimated from the published literature and claims data. Costs included treatment, follow-up, diagnostic testing, and retail pharmacy pain medication. Costs of SI joint disruption patients managed with nonoperative care were estimated from the 2005–2010 Medicare 5% Standard Analytic Files using primary International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis codes 720.2, 724.6, 739.4, 846.9, or 847.3. MIS fusion hospitalization cost was based on Diagnosis Related Group (DRG) payments of $46,700 (with major complications - DRG 459) and $27,800 (without major complications - DRG 460), weighted assuming 3.8% of patients have complications. MIS fusion professional fee was determined from the 2012 Medicare payment for Current Procedural Terminology code 27280, with an 82% fusion success rate and 1.8% revision rate. Outcomes were discounted by 3.0% per annum. Results The extrapolated lifetime cost of treating Medicare patients with MIS fusion was $48,185/patient compared to $51,543/patient for nonoperative care, resulting in a $660 million savings to Medicare (196,452 beneficiaries at $3,358 in savings/patient). Including those with ICD-9-CM code 721.3 (lumbosacral spondylosis) increased lifetime cost estimates (up to 478,764 beneficiaries at $8,692 in savings/patient). Conclusion Treating Medicare

  13. Using DRG to analyze hospital production: a re-classification model based on a linear tree-network topology

    Directory of Open Access Journals (Sweden)

    Achille Lanzarini

    2014-09-01

    Full Text Available Background: Hospital discharge records are widely classified through the Diagnosis Related Group (DRG system; the version currently used in Italy counts 538 different codes, including thousands of diagnosis and procedures. These numbers reflect the considerable effort of simplification, yet the current classification system is of little use to evaluate hospital production and performance.Methods: As the case-mix of a given Hospital Unit (HU is driven by its physicians’ specializations, a grouping of DRGs into a specialization-driven classification system has been conceived through the analysis of HUs discharging and the ICD-9-CM codes. We propose a three-folded classification, based on the analysis of 1,670,755 Hospital Discharge Cards (HDCs produced by Lombardy Hospitals in 2010; it consists of 32 specializations (e.g. Neurosurgery, 124 sub-specialization (e.g. skull surgery and 337 sub-sub-specialization (e.g. craniotomy.Results: We give a practical application of the three-layered approach, based on the production of a Neurosurgical HU; we observe synthetically the profile of production (1,305 hospital discharges for 79 different DRG codes of 16 different MDC are grouped in few groups of homogeneous DRG codes, a more informative production comparison (through process-specific comparisons, rather than crude or case-mix standardized comparisons and a potentially more adequate production planning (considering the Neurosurgical HUs of the same city, those produce a limited quote of the whole neurosurgical production, because the same activity can be realized by non-Neurosugical HUs.Conclusion: Our work may help to evaluate the hospital production for a rational planning of available resources, blunting information asymmetries between physicians and managers. 

  14. Fast-neutron, coded-aperture imager

    International Nuclear Information System (INIS)

    Woolf, Richard S.; Phlips, Bernard F.; Hutcheson, Anthony L.; Wulf, Eric A.

    2015-01-01

    This work discusses a large-scale, coded-aperture imager for fast neutrons, building off a proof-of concept instrument developed at the U.S. Naval Research Laboratory (NRL). The Space Science Division at the NRL has a heritage of developing large-scale, mobile systems, using coded-aperture imaging, for long-range γ-ray detection and localization. The fast-neutron, coded-aperture imaging instrument, designed for a mobile unit (20 ft. ISO container), consists of a 32-element array of 15 cm×15 cm×15 cm liquid scintillation detectors (EJ-309) mounted behind a 12×12 pseudorandom coded aperture. The elements of the aperture are composed of 15 cm×15 cm×10 cm blocks of high-density polyethylene (HDPE). The arrangement of the aperture elements produces a shadow pattern on the detector array behind the mask. By measuring of the number of neutron counts per masked and unmasked detector, and with knowledge of the mask pattern, a source image can be deconvolved to obtain a 2-d location. The number of neutrons per detector was obtained by processing the fast signal from each PMT in flash digitizing electronics. Digital pulse shape discrimination (PSD) was performed to filter out the fast-neutron signal from the γ background. The prototype instrument was tested at an indoor facility at the NRL with a 1.8-μCi and 13-μCi 252Cf neutron/γ source at three standoff distances of 9, 15 and 26 m (maximum allowed in the facility) over a 15-min integration time. The imaging and detection capabilities of the instrument were tested by moving the source in half- and one-pixel increments across the image plane. We show a representative sample of the results obtained at one-pixel increments for a standoff distance of 9 m. The 1.8-μCi source was not detected at the 26-m standoff. In order to increase the sensitivity of the instrument, we reduced the fastneutron background by shielding the top, sides and back of the detector array with 10-cm-thick HDPE. This shielding configuration led

  15. Fast-neutron, coded-aperture imager

    Energy Technology Data Exchange (ETDEWEB)

    Woolf, Richard S., E-mail: richard.woolf@nrl.navy.mil; Phlips, Bernard F., E-mail: bernard.phlips@nrl.navy.mil; Hutcheson, Anthony L., E-mail: anthony.hutcheson@nrl.navy.mil; Wulf, Eric A., E-mail: eric.wulf@nrl.navy.mil

    2015-06-01

    This work discusses a large-scale, coded-aperture imager for fast neutrons, building off a proof-of concept instrument developed at the U.S. Naval Research Laboratory (NRL). The Space Science Division at the NRL has a heritage of developing large-scale, mobile systems, using coded-aperture imaging, for long-range γ-ray detection and localization. The fast-neutron, coded-aperture imaging instrument, designed for a mobile unit (20 ft. ISO container), consists of a 32-element array of 15 cm×15 cm×15 cm liquid scintillation detectors (EJ-309) mounted behind a 12×12 pseudorandom coded aperture. The elements of the aperture are composed of 15 cm×15 cm×10 cm blocks of high-density polyethylene (HDPE). The arrangement of the aperture elements produces a shadow pattern on the detector array behind the mask. By measuring of the number of neutron counts per masked and unmasked detector, and with knowledge of the mask pattern, a source image can be deconvolved to obtain a 2-d location. The number of neutrons per detector was obtained by processing the fast signal from each PMT in flash digitizing electronics. Digital pulse shape discrimination (PSD) was performed to filter out the fast-neutron signal from the γ background. The prototype instrument was tested at an indoor facility at the NRL with a 1.8-μCi and 13-μCi 252Cf neutron/γ source at three standoff distances of 9, 15 and 26 m (maximum allowed in the facility) over a 15-min integration time. The imaging and detection capabilities of the instrument were tested by moving the source in half- and one-pixel increments across the image plane. We show a representative sample of the results obtained at one-pixel increments for a standoff distance of 9 m. The 1.8-μCi source was not detected at the 26-m standoff. In order to increase the sensitivity of the instrument, we reduced the fastneutron background by shielding the top, sides and back of the detector array with 10-cm-thick HDPE. This shielding configuration led

  16. Musculoskeletal disorder costs and medical claim filing in the US retail trade sector.

    Science.gov (United States)

    Bhattacharya, Anasua; Leigh, J Paul

    2011-01-01

    The average costs of Musculoskeletal Disorder (MSD) and odds ratios for filing medical claims related to MSD were examined. The medical claims were identified by ICD 9 codes for four US Census regions within retail trade. Large private firms' medical claims data from Thomson Reuters Inc. MarketScan databases for the years 2003 through 2006 were used. Average costs were highest for claims related to lumbar region (ICD 9 Code: 724.02) and number of claims were largest for low back syndrome (ICD 9 Code: 724.2). Whereas the odds of filing an MSD claim did not vary greatly over time, average costs declined over time. The odds of filing claims rose with age and were higher for females and southerners than men and non-southerners. Total estimated national medical costs for MSDs within retail trade were $389 million (2007 USD).

  17. Mental and behavioural disorders in the ICD-11: concepts, methodologies, and current status.

    Science.gov (United States)

    Gaebel, Wolfgang; Zielasek, Jürgen; Reed, Geoffrey M

    2017-04-30

    This review provides an overview of the concepts, methods and current status of the development of the Eleventh Revision of the Mental and Behavioural Disorders chapter of the International Classification of Diseases and Related Health Problems (ICD-11) by the World Health Organization (WHO). Given the global use of the current version (ICD-10) for a wide range of applications in clinical practice and health statistics, a major aim of the development process for ICD-11 has been to increase the utility of the classification system. Expert working groups with responsibility for specific disorder groupings first suggested a set of revised diagnostic guidelines. Then surveys were performed to obtain suggestions for revisions from practicing health professionals. A completely revised structure for the classification of mental and behavioural disorders was developed and major revisions were suggested, for example, for schizophrenia and other primary psychotic disorders, substance use disorders, affective disorders and personality disorders. A new category of "gaming disorder" has been proposed and conditions related to sexual health and gender identity will be classified separately from mental disorders. An ICD-11 beta draft is freely available on the internet and public comments are invited. Field studies of the revised diagnostic guidelines are in process to obtain additional information about necessary improvements. A tabulated crosswalk from previous ICD-10 to then ICD-11 criteria will be necessary to ascertain the continuity of diagnoses for epidemiological and other statistical purposes. The final version of ICD-11 is currently scheduled for release by the World Health Assembly in 2018.

  18. A Novel Criterion for Optimum MultilevelCoding Systems in Mobile Fading Channels

    Institute of Scientific and Technical Information of China (English)

    YUAN Dongfeng; WANG Chengxiang; YAO Qi; CAO Zhigang

    2001-01-01

    A novel criterion that is "capac-ity rule" and "mapping rule" for the design of op-timum MLC scheme over mobile fading channels isproposed.According to this theory,the performanceof multilevel coding with multistage decoding schemes(MLC/MSD) in mobile fading channels is investi-gated,in which BCH codes are chosen as componentcodes,and three mapping strategies with 8ASK mod-ulation are used.Numerical results indicate that whencode rates of component codes in MLC scheme are de-signed based on "capacity rule",the performance ofthe system with block partitioning (BP) is optimumfor Rayleigh fading channels,while the performance ofthe system with Ungerboeck partioning (UP) is bestfor AWGN channels.

  19. Rule-Based and Case-Based Reasoning in Housing Prices

    OpenAIRE

    Gabrielle Gayer; Itzhak Gilboa; Offer Lieberman

    2004-01-01

    People reason about real-estate prices both in terms of general rules and in terms of analogies to similar cases. We propose to empirically test which mode of reasoning fits the data better. To this end, we develop the statistical techniques required for the estimation of the case-based model. It is hypothesized that case-based reasoning will have relatively more explanatory power in databases of rental apartments, whereas rule-based reasoning will have a relative advantage in sales data. We ...

  20. Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress.

    Science.gov (United States)

    Hauser, R G; Hayes, D L; Almquist, A K; Epstein, A E; Parsonnet, V; Tyers, G F; Vlay, S C; Schoenfeld, M H

    2001-07-01

    Because it is a lifesaving device, the unexpected failure of an ICD can be catastrophic. We report ICD electronic circuit failure due to electrical overstress damage (EOS) to the high voltage hybird circuit and other electronic components in a series of ICD pulse generator models. Data were obtained from the Multicenter Registry of Pacemaker and ICD Pacemaker and Lead Failures, and from the manufactures' adverse event reports, that were in the FDA's Manufacturer and User Facility Device Experience (MAUDE) database. Of 16 nonbattery Guidant/CPI ICD pulse generator failures reported to the registry, 6 (38%) have been confirmed by the manufacturer to be EOS related, and Guidant/CPI has reported 273 such failures to the FDA as of 12/29/00. The signs of failure included loss of telemetry and inability to deliver therapy, and some patients have experienced serious adverse events. Hybrid circuit damage may have occurred during capacitor charging or reform, and the majority appears to have happened during normal ICD function. While the incidence of this problem is unknown, a management strategy should be adopted that includes routine follow-up every 3 months and device evaluation after a shock or exposure to external defibrillation or electrosurgical devices. This study suggests that additional data are needed to determine the incidence of this problem, and that our present methods for monitoring the performance of ICD's following market release are inadequate.

  1. Benchmarking the cad-based attila discrete ordinates code with experimental data of fusion experiments and to the results of MCNP code in simulating ITER

    International Nuclear Information System (INIS)

    Youssef, M. Z.

    2007-01-01

    Attila is a newly developed finite element code based on Sn neutron, gamma, and charged particle transport in 3-D geometry in which unstructured tetrahedral meshes are generated to describe complex geometry that is based on CAD input (Solid Works, Pro/Engineer, etc). In the present work we benchmark its calculation accuracy by comparing its prediction to the measured data inside two experimental mock-ups bombarded with 14 MeV neutrons. The results are also compared to those based on MCNP calculations. The experimental mock-ups simulate parts of the International Thermonuclear Experimental Reactor (ITER) in-vessel components, namely: (1) the Tungsten mockup configuration (54.3 cm x 46.8 cm x 45 cm), and (2) the ITER shielding blanket followed by the SCM region (simulated by alternating layers of SS316 and copper). In the latter configuration, a high aspect ratio rectangular streaming channel was introduced (to simulate steaming paths between ITER blanket modules) which ends with a rectangular cavity. The experiments on these two fusion-oriented integral experiments were performed at the Fusion Neutron Generator (FNG) facility, Frascati, Italy. In addition, the nuclear performance of the ITER MCNP 'Benchmark' CAD model has been performed with Attila to compare its results to those obtained with CAD-based MCNP approach developed by several ITER participants. The objective of this paper is to compare results based on two distinctive 3-D calculation tools using the same nuclear data, FENDL2.1, and the same response functions of several reaction rates measured in ITER mock-ups and to enhance confidence from the international neutronics community in the Attila code and how it can precisely quantify the nuclear field in large and complex systems, such as ITER. Attila has the advantage of providing a full flux mapping visualization everywhere in one run where components subjected to excessive radiation level and strong streaming paths can be identified. In addition, the

  2. What Are They Talking About? Analyzing Code Reviews in Pull-Based Development Model

    Institute of Scientific and Technical Information of China (English)

    Zhi-Xing Li; Yue Yu; Gang Yin; Tao Wang; Huai-Min Wang

    2017-01-01

    Code reviews in pull-based model are open to community users on GitHub. Various participants are taking part in the review discussions and the review topics are not only about the improvement of code contributions but also about project evolution and social interaction. A comprehensive understanding of the review topics in pull-based model would be useful to better organize the code review process and optimize review tasks such as reviewer recommendation and pull-request prioritization. In this paper, we first conduct a qualitative study on three popular open-source software projects hosted on GitHub and construct a fine-grained two-level taxonomy covering four level-1 categories (code correctness, pull-request decision-making, project management, and social interaction) and 11 level-2 subcategories (e.g., defect detecting, reviewer assigning, contribution encouraging). Second, we conduct preliminary quantitative analysis on a large set of review comments that were labeled by TSHC (a two-stage hybrid classification algorithm), which is able to automatically classify review comments by combining rule-based and machine-learning techniques. Through the quantitative study, we explore the typical review patterns. We find that the three projects present similar comments distribution on each subcategory. Pull-requests submitted by inexperienced contributors tend to contain potential issues even though they have passed the tests. Furthermore, external contributors are more likely to break project conventions in their early contributions.

  3. Deaths related to lead poisoning in the United States, 1979-1998

    International Nuclear Information System (INIS)

    Kaufmann, R.B.; Staes, Catherine J.; Matte, Thomas D.

    2003-01-01

    This study was conducted to describe trends in US lead poisoning-relate deaths between 1979 and 1998. The predictive value of relevant ICD-9 codes was also evaluated. Multiple cause-of-death files were searched for record containing relevant ICD-9 codes, and underlying causes and demographic characteristics were assessed. For 1979-1988, death certificates were reviewed; lead source information was abstracted and accuracy of coding was determined. An estimated 200 lead poisoning-related deaths occurred from 1979 to 1998. Most were among males (74%), Blacks (67%), adults of age ≥45 years (76%), and Southerners (70%). The death rate was significantly lower in more recent years. An alcohol-related code was a contributing cause for 28% of adults. Only three of nine ICD-9 codes for lead poisoning were highl predictive of lead poisoning-related deaths. In conclusion, lead poisoning-related death rates have dropped dramatically since earlier decades and are continuing to decline. However, the findings imply that moonshine ingestion remains a source of high-dose lead exposure in adults

  4. Rulemaking efforts on codes and standards

    International Nuclear Information System (INIS)

    Millman, G.C.

    1992-01-01

    Section 50.55a of the NRC regulations provides a mechanism for incorporating national codes and standards into the regulatory process. It incorporates by reference ASME Boiler and Pressure Vessel Code (ASME B and PV Code) Section 3 rules for construction and Section 11 rules for inservice inspection and inservice testing. The regulation is periodically amended to update these references. The rulemaking process, as applied to Section 50.55a amendments, is overviewed to familiarize users with associated internal activities of the NRC staff and the manner in which public comments are integrated into the process. The four ongoing rulemaking actions that would individually amend Section 50.55a are summarized. Two of the actions would directly impact requirements for inservice testing. Benefits accrued with NRC endorsement of the ASME B and PV Code, and possible future endorsement of the ASME Operations and Maintenance Code (ASME OM Code), are identified. Emphasis is placed on the need for code writing committees to be especially sensitive to user feedback on code rules incorporated into the regulatory process to ensure that the rules are complete, technically accurate, clear, practical, and enforceable

  5. Structural evaluation method for class 1 vessels by using elastic-plastic finite element analysis in code case of JSME rules on design and construction

    International Nuclear Information System (INIS)

    Asada, Seiji; Hirano, Takashi; Nagata, Tetsuya; Kasahara, Naoto

    2008-01-01

    A structural evaluation method by using elastic-plastic finite element analysis has been developed and published as a code case of Rules on Design and Construction for Nuclear Power Plants (The First Part: Light Water Reactor Structural Design Standard) in the JSME Codes for Nuclear Power Generation Facilities. Its title is 'Alternative Structural Evaluation Criteria for Class 1 Vessels Based on Elastic-Plastic Finite Element Analysis' (NC-CC-005). This code case applies elastic-plastic analysis to evaluation of such failure modes as plastic collapse, thermal ratchet, fatigue and so on. Advantage of this evaluation method is free from stress classification, consistently use of Mises stress and applicability to complex 3-dimensional structures which are hard to be treated by the conventional stress classification method. The evaluation method for plastic collapse has such variation as the Lower Bound Approach Method, Twice-Elastic-Slope Method and Elastic Compensation Method. Cyclic Yield Area (CYA) based on elastic analysis is applied to screening evaluation of thermal ratchet instead of secondary stress evaluation, and elastic-plastic analysis is performed when the CYA screening criteria is not satisfied. Strain concentration factors can be directly calculated based on elastic-plastic analysis. (author)

  6. QC-LDPC code-based cryptography

    CERN Document Server

    Baldi, Marco

    2014-01-01

    This book describes the fundamentals of cryptographic primitives based on quasi-cyclic low-density parity-check (QC-LDPC) codes, with a special focus on the use of these codes in public-key cryptosystems derived from the McEliece and Niederreiter schemes. In the first part of the book, the main characteristics of QC-LDPC codes are reviewed, and several techniques for their design are presented, while tools for assessing the error correction performance of these codes are also described. Some families of QC-LDPC codes that are best suited for use in cryptography are also presented. The second part of the book focuses on the McEliece and Niederreiter cryptosystems, both in their original forms and in some subsequent variants. The applicability of QC-LDPC codes in these frameworks is investigated by means of theoretical analyses and numerical tools, in order to assess their benefits and drawbacks in terms of system efficiency and security. Several examples of QC-LDPC code-based public key cryptosystems are prese...

  7. Development and validation of an ICD-10-based disability predictive index for patients admitted to hospitals with trauma.

    Science.gov (United States)

    Wada, Tomoki; Yasunaga, Hideo; Yamana, Hayato; Matsui, Hiroki; Fushimi, Kiyohide; Morimura, Naoto

    2018-03-01

    There was no established disability predictive measurement for patients with trauma that could be used in administrative claims databases. The aim of the present study was to develop and validate a diagnosis-based disability predictive index for severe physical disability at discharge using the International Classification of Diseases, 10th revision (ICD-10) coding. This retrospective observational study used the Diagnosis Procedure Combination database in Japan. Patients who were admitted to hospitals with trauma and discharged alive from 01 April 2010 to 31 March 2015 were included. Pediatric patients under 15 years old were excluded. Data for patients admitted to hospitals from 01 April 2010 to 31 March 2013 was used for development of a disability predictive index (derivation cohort), while data for patients admitted to hospitals from 01 April 2013 to 31 March 2015 was used for the internal validation (validation cohort). The outcome of interest was severe physical disability defined as the Barthel Index score of predictive index for each patient was defined as the sum of the scores. The predictive performance of the index was validated using the receiver operating characteristic curve analysis in the validation cohort. The derivation cohort included 1,475,158 patients, while the validation cohort included 939,659 patients. Of the 939,659 patients, 235,382 (25.0%) were discharged with severe physical disability. The c-statistics of the disability predictive index was 0.795 (95% confidence interval [CI] 0.794-0.795), while that of a model using the disability predictive index and patient baseline characteristics was 0.856 (95% CI 0.855-0.857). Severe physical disability at discharge may be well predicted with patient age, sex, CCI score, and the diagnosis-based disability predictive index in patients admitted to hospitals with trauma. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Definition of Business Rules Using Business Vocabulary and Semantics

    Directory of Open Access Journals (Sweden)

    Roman Hypský

    2017-12-01

    Full Text Available This paper discusses the definition of business rules using business vocabulary and semantics. At the beginning business rules, business vocabulary and semantics of business rules are specified. There is also outlined the current state of research on this topic. Then the definition and formalization of business rules using semantics and business vocabulary is described. Based on these proposed procedures was created a tool that implements and simulate these processes. The main advantage of this tool is “Business Rules Layer”, which implements business rules into the system but is separated from this system. Source code of the rules and the system are not mixed together. Finally, the results are evaluated and future development is suggested.

  9. Genome-scale transcriptional activation by an engineered CRISPR-Cas9 complex.

    Science.gov (United States)

    Konermann, Silvana; Brigham, Mark D; Trevino, Alexandro E; Joung, Julia; Abudayyeh, Omar O; Barcena, Clea; Hsu, Patrick D; Habib, Naomi; Gootenberg, Jonathan S; Nishimasu, Hiroshi; Nureki, Osamu; Zhang, Feng

    2015-01-29

    Systematic interrogation of gene function requires the ability to perturb gene expression in a robust and generalizable manner. Here we describe structure-guided engineering of a CRISPR-Cas9 complex to mediate efficient transcriptional activation at endogenous genomic loci. We used these engineered Cas9 activation complexes to investigate single-guide RNA (sgRNA) targeting rules for effective transcriptional activation, to demonstrate multiplexed activation of ten genes simultaneously, and to upregulate long intergenic non-coding RNA (lincRNA) transcripts. We also synthesized a library consisting of 70,290 guides targeting all human RefSeq coding isoforms to screen for genes that, upon activation, confer resistance to a BRAF inhibitor. The top hits included genes previously shown to be able to confer resistance, and novel candidates were validated using individual sgRNA and complementary DNA overexpression. A gene expression signature based on the top screening hits correlated with markers of BRAF inhibitor resistance in cell lines and patient-derived samples. These results collectively demonstrate the potential of Cas9-based activators as a powerful genetic perturbation technology.

  10. Piping design and analysis: Comparison between the Belgian applications of French and American rules

    International Nuclear Information System (INIS)

    Daoust, P.H.; Geraets, L.H.; Lafaille, J.P.

    1987-01-01

    In the process of a feasibility study of a new nuclear power plant in Belgium, the French and American rules for piping design have been compared. The Belgian method rests on the American nuclear set of rules and uses the ASME code. French rules were initially based on the American rules (1978). Subsequent individual development led to a differentiation of the rules. Presently the mechanical part of the French rules is mainly contained in the RCC-P ('Regles de Conception et de Construction relatives aux Procedes') and the RCC-M ('Regles de Conception et de Construction des Materiels Mecaniques'). This paper compares the piping design rules from a general point of view; examples of applications allow to identify benefits or drawbacks of the use of ASME or RCCM codes. (orig.)

  11. Piping design and analysis: comparison between the Belgian applications of French and American rules

    International Nuclear Information System (INIS)

    Daoust, Ph.; Geraets, L.H.; Lafaille, J.P.

    1989-01-01

    In the process of a feasibility study of a new nuclear power plant in Belgium, the French and American rules for piping design have been compared. The Belgian method rests on the American nuclear set of rules and uses the ASME code. French rules were initially based on the American rules (1978). Subsequent individual development led to a differentiation of the rules. Presently, the mechanical part of the French rules is mainly contained in the RCCP ('Regles de Conception et de Construction relatives aux Procedes') and the RCCM ('Regles de Conception et de Construction des materiels Mecaniques'). This paper compares the piping design rules from a general point of view; examples of applications allow benefits or drawbacks of the use of ASME or RCCM codes to identified. (author)

  12. Coding chaotic billiards. Pt. 3

    International Nuclear Information System (INIS)

    Ullmo, D.; Giannoni, M.J.

    1993-01-01

    Non-tiling compact billiard defined on the pseudosphere is studied 'a la Morse coding'. As for most bounded systems, the coding is non exact. However, two sets of approximate grammar rules can be obtained, one specifying forbidden codes, and the other allowed ones. In-between some sequences remain in the 'unknown' zone, but their relative amount can be reduced to zero if one lets the length of the approximate grammar rules goes to infinity. The relationship between these approximate grammar rules and the 'pruning front' introduced by Cvitanovic et al. is discussed. (authors). 13 refs., 10 figs., 1 tab

  13. Prognostic value of microvolt T-wave alternans in a real-world ICD population. Twente ICD Cohort Studie (TICS)

    NARCIS (Netherlands)

    Kraaier, K.; Olimulder, M. A. G. M.; van Dessel, P. F. H. M.; Wilde, A. A. M.; Scholten, M. F.

    2014-01-01

    Introduction Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this

  14. Development of an inelastic stress analysis code 'KINE-T' and its evaluations

    International Nuclear Information System (INIS)

    Kobatake, K.; Takahashi, S.; Suzuki, M.

    1977-01-01

    Referring to the ASME B and PVC Code Case 1592-7, the inelastic stress analysis is required for the designs of the class 1 components in elevated temperature if the results of the elastic stress analysis and/or simplified inelastic analysis do not satisfy the requirements. Authors programmed a two-dimensional axisymmetric inelastic analysis code 'KINE-T', and carried out its evaluations and an application. This FEM code is based on the incremental method and the following: elastic-plastic constitutive equation (yield condition of von Mises; flow rule of Prandtl-Reuss; Prager's hardening rule); creep constitutive equation (equation of state approach; flow rule of von Mises; strain hardening rule); the temperature dependency of the yield function is considered; solution procedure of the assembled stiffness matrix is the 'initial stress method'. After the completion of the programming, authors compared the output with not only theoretical results but also with those of the MARC code and the ANSYS code. In order to apply the code to the practical designing, authors settled a quasi-component two-dimensional axisymmetric model and a loading cycle (500 cycles). Then, an inelastic analysis and its integrity evaluation are carried out

  15. Gender Incongruence of Adolescence and Adulthood: Acceptability and Clinical Utility of the World Health Organization's Proposed ICD-11 Criteria.

    Directory of Open Access Journals (Sweden)

    Titia F Beek

    Full Text Available The World Health Organization (WHO is currently updating the tenth version of their diagnostic tool, the International Classification of Diseases (ICD, WHO, 1992. Changes have been proposed for the diagnosis of Transsexualism (ICD-10 with regard to terminology, placement and content. The aim of this study was to gather the opinions of transgender individuals (and their relatives/partners and clinicians in the Netherlands, Flanders (Belgium and the United Kingdom regarding the proposed changes and the clinical applicability and utility of the ICD-11 criteria of 'Gender Incongruence of Adolescence and Adulthood' (GIAA. A total of 628 participants were included in the study: 284 from the Netherlands (45.2%, 8 from Flanders (Belgium (1.3%, and 336 (53.5% from the UK. Most participants were transgender people (or their partners/relatives (n = 522, 89 participants were healthcare providers (HCPs and 17 were both healthcare providers and (partners/relatives of transgender people. Participants completed an online survey developed for this study. Most participants were in favor of the proposed diagnostic term of 'Gender Incongruence' and thought that this was an improvement on the ICD-10 diagnostic term of 'Transsexualism'. Placement in a separate chapter dealing with Sexual- and Gender-related Health or as a Z-code was preferred by many and only a small number of participants stated that this diagnosis should be excluded from the ICD-11. In the UK, most transgender participants thought there should be a diagnosis related to being trans. However, if it were to be removed from the chapter on "psychiatric disorders", many transgender respondents indicated that they would prefer it to be removed from the ICD in its entirety. There were no large differences between the responses of the transgender participants (or their partners and relatives and HCPs. HCPs were generally positive about the GIAA diagnosis; most thought the diagnosis was clearly defined and

  16. The 1-month prevalence of generalized anxiety disorder according to DSM-IV, DSM-V, and ICD-10 among nondemented 75-year-olds in Gothenburg, Sweden.

    Science.gov (United States)

    Nilsson, Johan; Östling, Svante; Waern, Margda; Karlsson, Björn; Sigström, Robert; Guo, Xinxin; Skoog, Ingmar

    2012-11-01

    To examine the 1-month prevalence of generalized anxiety disorder (GAD) according to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), Diagnostic and Statistical Manual of Mental, Fifth Edition (DSM-V), and International Classification of Diseases, Tenth Revision (ICD-10), and the overlap between these criteria, in a population sample of 75-year-olds. We also aimed to examine comorbidity between GAD and other psychiatric diagnoses, such as depression. During 2005-2006, a comprehensive semistructured psychiatric interview was conducted by trained nurses in a representative population sample of 75-year-olds without dementia in Gothenburg, Sweden (N = 777; 299 men and 478 women). All psychiatric diagnoses were made according to DSM-IV. GAD was also diagnosed according to ICD-10 and DSM-V. The 1-month prevalence of GAD was 4.1% (N = 32) according to DSM-IV, 4.5% (N = 35) according to DSM-V, and 3.7% (N = 29) according to ICD-10. Only 46.9% of those with DSM-IV GAD fulfilled ICD-10 criteria, and only 51.7% and 44.8% of those with ICD-10 GAD fulfilled DSM-IV/V criteria. Instead, 84.4% and 74.3% of those with DSM-IV/V GAD and 89.7% of those with ICD-10 GAD had depression. Also other psychiatric diagnoses were common in those with ICD-10 and DSM-IV GAD. Only a small minority with GAD, irrespective of criteria, had no other comorbid psychiatric disorder. ICD-10 GAD was related to an increased mortality rate. While GAD was common in 75-year-olds, DSM-IV/V and ICD-10 captured different individuals. Current definitions of GAD may comprise two different expressions of the disease. There was greater congruence between GAD in either classification system and depression than between DSM-IV/V GAD and ICD-10 GAD, emphasizing the close link between these entities. 2012 American Association for Geriatric Psychiatry

  17. The association of peptic ulcer and schizophrenia: a population-based study.

    Science.gov (United States)

    Liao, Chun-Hui; Chang, Chen-Shu; Chang, Shih-Ni; Muo, Chih-Hsin; Lane, Hsien-Yuan; Sung, Fung-Chang; Kao, Chia-Hung

    2014-12-01

    The association of schizophrenia with peptic ulcer is not conclusive. In the last 30years, there has been little evaluation of peptic ulcer among schizophrenia patients. To explore the relation of peptic ulcer and schizophrenia during this new phase, we used the data from Taiwan insurance claims, identified 1496 schizophrenia patients (ICD-9-CM: 295) and selected 5984 non-schizophrenia controls that were frequency-matched by sex, age, and index year with schizophrenia patients during the years 1998-2001. All subjects were free of peptic ulcer at baseline. We measured incidences of peptic ulcer (ICD-9-CM: 531-534) until the end of 2009. The incidence of peptic ulcer was 1.27 times higher in schizophrenia patients than in the control group (12.1vs. 9.52 per 1000 person-years). Patients are at higher risk taking anti-depression, anxiolytic and hypnotics or non-steroidal anti-inflammatory drugs. After controlling the confounding factors, schizophrenia patients had no significant increase incidence of peptic ulcer. Schizophrenia patients have a slightly higher risk of peptic ulcer compared to the general population. This might be due to a higher rate of taking anti-depression, anxiolytic and hypnotics or non-steroidal anti-inflammatory drugs and alcoholism among this group. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Administrative Algorithms to identify Avascular necrosis of bone among patients undergoing upper or lower extremity magnetic resonance imaging: a validation study.

    Science.gov (United States)

    Barbhaiya, Medha; Dong, Yan; Sparks, Jeffrey A; Losina, Elena; Costenbader, Karen H; Katz, Jeffrey N

    2017-06-19

    Studies of the epidemiology and outcomes of avascular necrosis (AVN) require accurate case-finding methods. The aim of this study was to evaluate performance characteristics of a claims-based algorithm designed to identify AVN cases in administrative data. Using a centralized patient registry from a US academic medical center, we identified all adults aged ≥18 years who underwent magnetic resonance imaging (MRI) of an upper/lower extremity joint during the 1.5 year study period. A radiologist report confirming AVN on MRI served as the gold standard. We examined the sensitivity, specificity, positive predictive value (PPV) and positive likelihood ratio (LR + ) of four algorithms (A-D) using International Classification of Diseases, 9th edition (ICD-9) codes for AVN. The algorithms ranged from least stringent (Algorithm A, requiring ≥1 ICD-9 code for AVN [733.4X]) to most stringent (Algorithm D, requiring ≥3 ICD-9 codes, each at least 30 days apart). Among 8200 patients who underwent MRI, 83 (1.0% [95% CI 0.78-1.22]) had AVN by gold standard. Algorithm A yielded the highest sensitivity (81.9%, 95% CI 72.0-89.5), with PPV of 66.0% (95% CI 56.0-75.1). The PPV of algorithm D increased to 82.2% (95% CI 67.9-92.0), although sensitivity decreased to 44.6% (95% CI 33.7-55.9). All four algorithms had specificities >99%. An algorithm that uses a single billing code to screen for AVN among those who had MRI has the highest sensitivity and is best suited for studies in which further medical record review confirming AVN is feasible. Algorithms using multiple billing codes are recommended for use in administrative databases when further AVN validation is not feasible.

  19. Anxiety and Depression in Patients with Traumatic Spinal Cord Injury: A Nationwide Population-Based Cohort Study.

    Directory of Open Access Journals (Sweden)

    Sher-Wei Lim

    Full Text Available Traumatic spinal cord injury (tSCI may involve new-onset anxiety and depression post-discharge. However, long-term population-based studies have lacked access to follow-up conditions in terms of new-onset anxiety and depression. The objective of this study was to estimate the long-term risk of new-onset anxiety and depression post-discharge.The Longitudinal Health Insurance Database 2000 (LHID2000 from Taiwan's National Health Insurance Research Database was used in this study. Individuals with tSCI were identified using the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM diagnostic codes of 806 and 952 from 1999-2008. The comparison cohort (other health conditions group was randomly selected from the LHID2000 and was 1:1 matched by age, sex, index year, and comorbidities to reduce the selection bias. All study participants were retrospectively followed for a maximum of 3 years until the end of follow-up, death, or new-onset anxiety (ICD-9-CM: 309.2-309.4 or depression (ICD-9-CM: 296.2, 296.5, 296.82, 300.4, 309.0-309.1, and 311. Persons who were issued a catastrophic illness card for tSCI were categorized as having a severe level of SCI (Injury Severity Score [ISS] ≥16. Poisson regression was used to estimate the incidence rate ratios of anxiety or depression between patients with tSCI and other health conditions. The relative risk of anxiety or depression was estimated using a Cox regression analysis, which was adjusted for potential confounding factors.Univariate analyses showed that the tSCI patients (n = 3556 had a 1.33 times greater incidence of new-onset anxiety or depression (95% confidence interval [CI]: 1.12-1.57 compared to the other health conditions group (n = 3556. After adjusting for potential risk factors, the tSCI patients had a significant 1.29-fold increased risk of anxiety or depression compared to the group with other health conditions (95% CI: 1.09-1.53. Individuals with t

  20. Development and validation of a structured query language implementation of the Elixhauser comorbidity index.

    Science.gov (United States)

    Epstein, Richard H; Dexter, Franklin

    2017-07-01

    Comorbidity adjustment is often performed during outcomes and health care resource utilization research. Our goal was to develop an efficient algorithm in structured query language (SQL) to determine the Elixhauser comorbidity index. We wrote an SQL algorithm to calculate the Elixhauser comorbidities from Diagnosis Related Group and International Classification of Diseases (ICD) codes. Validation was by comparison to expected comorbidities from combinations of these codes and to the 2013 Nationwide Readmissions Database (NRD). The SQL algorithm matched perfectly with expected comorbidities for all combinations of ICD-9 or ICD-10, and Diagnosis Related Groups. Of 13 585 859 evaluable NRD records, the algorithm matched 100% of the listed comorbidities. Processing time was ∼0.05 ms/record. The SQL Elixhauser code was efficient and computationally identical to the SAS algorithm used for the NRD. This algorithm may be useful where preprocessing of large datasets in a relational database environment and comorbidity determination is desired before statistical analysis. A validated SQL procedure to calculate Elixhauser comorbidities and the van Walraven index from ICD-9 or ICD-10 discharge diagnosis codes has been published. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  1. Coding conventions and principles for a National Land-Change Modeling Framework

    Science.gov (United States)

    Donato, David I.

    2017-07-14

    This report establishes specific rules for writing computer source code for use with the National Land-Change Modeling Framework (NLCMF). These specific rules consist of conventions and principles for writing code primarily in the C and C++ programming languages. Collectively, these coding conventions and coding principles create an NLCMF programming style. In addition to detailed naming conventions, this report provides general coding conventions and principles intended to facilitate the development of high-performance software implemented with code that is extensible, flexible, and interoperable. Conventions for developing modular code are explained in general terms and also enabled and demonstrated through the appended templates for C++ base source-code and header files. The NLCMF limited-extern approach to module structure, code inclusion, and cross-module access to data is both explained in the text and then illustrated through the module templates. Advice on the use of global variables is provided.

  2. Risk-based rules for crane safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Ruud, Stian [Section for Control Systems, DNV Maritime, 1322 Hovik (Norway)], E-mail: Stian.Ruud@dnv.com; Mikkelsen, Age [Section for Lifting Appliances, DNV Maritime, 1322 Hovik (Norway)], E-mail: Age.Mikkelsen@dnv.com

    2008-09-15

    The International Maritime Organisation (IMO) has recommended a method called formal safety assessment (FSA) for future development of rules and regulations. The FSA method has been applied in a pilot research project for development of risk-based rules and functional requirements for systems and components for offshore crane systems. This paper reports some developments in the project. A method for estimating target reliability for the risk-control options (safety functions) by means of the cost/benefit decision criterion has been developed in the project and is presented in this paper. Finally, a structure for risk-based rules is proposed and presented.

  3. Risk-based rules for crane safety systems

    International Nuclear Information System (INIS)

    Ruud, Stian; Mikkelsen, Age

    2008-01-01

    The International Maritime Organisation (IMO) has recommended a method called formal safety assessment (FSA) for future development of rules and regulations. The FSA method has been applied in a pilot research project for development of risk-based rules and functional requirements for systems and components for offshore crane systems. This paper reports some developments in the project. A method for estimating target reliability for the risk-control options (safety functions) by means of the cost/benefit decision criterion has been developed in the project and is presented in this paper. Finally, a structure for risk-based rules is proposed and presented

  4. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  5. Derivative-Based Trapezoid Rule for the Riemann-Stieltjes Integral

    Directory of Open Access Journals (Sweden)

    Weijing Zhao

    2014-01-01

    Full Text Available The derivative-based trapezoid rule for the Riemann-Stieltjes integral is presented which uses 2 derivative values at the endpoints. This kind of quadrature rule obtains an increase of two orders of precision over the trapezoid rule for the Riemann-Stieltjes integral and the error term is investigated. At last, the rationality of the generalization of derivative-based trapezoid rule for Riemann-Stieltjes integral is demonstrated.

  6. An evaluation of ICD-11 PTSD and complex PTSD criteria in a sample of adult survivors of childhood institutional abuse

    Directory of Open Access Journals (Sweden)

    Matthias Knefel

    2013-12-01

    Full Text Available Background : The WHO recently launched the proposal for the 11th version of the International Classification of Diseases (ICD-11 that also includes two diagnoses related to traumatic stress. In contrast to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5, ICD-11 will probably, in addition to posttraumatic stress disorder (PTSD, also define a new diagnosis termed “complex posttraumatic stress disorder” (CPTSD. Objective : We aimed to apply the proposed ICD-11 criteria for PTSD and CPTSD and to compare their prevalence to the ICD-10 (International Classification of Diseases [10th revision] PTSD prevalence. In addition, we compiled a list of symptoms for CPTSD based on subthreshold PTSD so as to include a wider group of individuals. Methods : To evaluate the appropriateness of the WHO ICD-11 proposal compared to the criteria of ICD-10, we applied the newly introduced criteria for PTSD and CPTSD deriving from the Posttraumatic Stress Disorder Checklist – Civilian Version (PCL-C and the Brief Symptom Inventory (BSI scales, to a sample of adult survivors (N=229 of childhood institutional abuse. We evaluated the construct validity of CPTSD using confirmatory factor analysis (CFA. Results : More individuals fulfilled the criteria for PTSD according to ICD-10 (52.8% than the ICD-11 proposal (17% for PTSD only; 38.4% if combined with complex PTSD. The new version of PTSD neutralized the gender effects. The prevalence of CPTSD was 21.4%, and women had a significantly higher rate of CPTSD than men (40.4 and 15.8%, respectively. Those survivors who were diagnosed with CPTSD experienced institutional abuse for a longer time. CFA showed a strong model fit. Conclusion : CPTSD is a highly relevant classification for individuals with complex trauma history, but surprisingly, effects of gender were apparent. Further research should thus address gender effects.

  7. Revised Rules for Concrete Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Jensen, F. M.; Middleton, C.

    This paper is based on research performed for the Highway Agency, London, UK under the project DPU/9/44 "Revision of Bridge Assessment Rules Based on Whole Life Performance: Concrete Bridges" It contains details of a methodology which can be used to generate Whole Life (WL) reliability profiles....... These WL reliability profiles may be used to establish revised rules for Concrete Bridges....

  8. microRNA-9 targets the long non-coding RNA MALAT1 for degradation in the nucleus

    DEFF Research Database (Denmark)

    Leucci, Eleonora; Patella, Francesca; Waage, Johannes

    2013-01-01

    -coding RNAs. Here we report that microRNA-9 (miR-9) regulates the expression of the Metastasis Associated Lung Adenocarcinoma Transcript 1 (MALAT-1), one of the most abundant and conserved long non-coding RNAs. Intriguingly, we find that miR-9 targets AGO2-mediated regulation of MALAT1 in the nucleus. Our...

  9. Nuclear Ep-ICD expression is a predictor of poor prognosis in "low risk" prostate adenocarcinomas.

    Directory of Open Access Journals (Sweden)

    Jasmeet Assi

    Full Text Available Molecular markers for predicting prostate cancer (PCa that would have poor prognosis are urgently needed for a more personalized treatment for patients. Regulated intramembrane proteolysis of Epithelial cell adhesion molecule results in shedding of the extracellular domain (EpEx and release of its intracellular domain (Ep-ICD which triggers oncogenic signaling and might correlate to tumor aggressiveness. This study aimed to explore the potential of Ep-ICD and EpEx to identify PCa that have poor prognosis.Immunohistochemical analysis of Ep-ICD and EpEx was carried out in normal prostate tissues (n = 100, benign prostate hyperplasia (BPH, n = 83, and prostate cancer (n = 249 using domain specific antibodies. The expression of Ep-ICD and EpEx was correlated with clinico- pathological parameters and disease free survival (DFS.Reduced expression of nuclear Ep-ICD and membrane EpEx was observed in PCa in comparison with BPH and normal prostate tissues (p = 0.006, p < 0.001 respectively. For patients who had PCa with Gleason Score less than 7, preserved nuclear Ep-ICD emerged as the most significant marker in multivariate analysis for prolonged DFS, where these patients did not have recurrence during follow up of up to 12 years (p = 0.001.Reduced expression of nuclear Ep-ICD was associated with shorter disease free survival in patients with a Gleason Score less than 7 and may be useful in identifying patients likely to have aggressive tumors with poor prognosis. Furthermore, nuclear Ep-ICD can differentiate between normal and prostate cancer tissues for ambiguous cases.

  10. Evaluation of clinical coding data to determine causes of critical bleeding in patients receiving massive transfusion: a bi-national, multicentre, cross-sectional study.

    Science.gov (United States)

    McQuilten, Z K; Zatta, A J; Andrianopoulos, N; Aoki, N; Stevenson, L; Badami, K G; Bird, R; Cole-Sinclair, M F; Hurn, C; Cameron, P A; Isbister, J P; Phillips, L E; Wood, E M

    2017-04-01

    To evaluate the use of routinely collected data to determine the cause(s) of critical bleeding in patients who receive massive transfusion (MT). Routinely collected data are increasingly being used to describe and evaluate transfusion practice. Chart reviews were undertaken on 10 randomly selected MT patients at 48 hospitals across Australia and New Zealand to determine the cause(s) of critical bleeding. Diagnosis-related group (DRG) and International Classification of Diseases (ICD) codes were extracted separately and used to assign each patient a cause of critical bleeding. These were compared against chart review using percentage agreement and kappa statistics. A total of 427 MT patients were included with complete ICD and DRG data for 427 (100%) and 396 (93%), respectively. Good overall agreement was found between chart review and ICD codes (78·3%; κ = 0·74, 95% CI 0·70-0·79) and only fair overall agreement with DRG (51%; κ = 0·45, 95% CI 0·40-0·50). Both ICD and DRG were sensitive and accurate for classifying obstetric haemorrhage patients (98% sensitivity and κ > 0·94). However, compared with the ICD algorithm, DRGs were less sensitive and accurate in classifying bleeding as a result of gastrointestinal haemorrhage (74% vs 8%; κ = 0·75 vs 0·1), trauma (92% vs 62%; κ = 0·78 vs 0·67), cardiac (80% vs 57%; κ = 0·79 vs 0·60) and vascular surgery (64% vs 56%; κ = 0·69 vs 0·65). Algorithms using ICD codes can determine the cause of critical bleeding in patients requiring MT with good to excellent agreement with clinical history. DRG are less suitable to determine critical bleeding causes. © 2016 British Blood Transfusion Society.

  11. Acute/subacute cerebral infarction (ASCI) in HIV-negative adults with cryptococcal meningoencephalitis (CM): a MRI-based follow-up study and a clinical comparison to HIV-negative CM adults without ASCI.

    Science.gov (United States)

    Chen, Shu-Fang; Lu, Cheng-Hsien; Lui, Chun-Chung; Huang, Chi-Ren; Chuang, Yao-Chung; Tan, Teng-Yeow; Tsai, Nai-Wen; Chang, Chiung-Chih; Tsai, Wan-Chen; Chang, Wen-Neng

    2011-01-26

    Acute/subacute cerebral infarction (ASCI) in HIV-negative cryptococcal meningoencephalitis (CM) adults has rarely been examined by a series of MRI-based follow-up study. We studied a series of MRI follow-up study of CM adults and compared the clinical characters of those with ASCI and those without ASCI. The clinical characteristics and a series of brain MRI findings of seven CM adults with ASCI were enrolled for analysis. The clinical characteristics of another 30 HIV-negative CM adults who did not have ASCI were also included for a comparative analysis. The seven HIV-negative CM adults with ASCI were four men and three women, aged 46-78 years. Lacunar infarction was the type of ASCI, and 86% (6/7) of the ACSI were multiple infarctions distributed in both the anterior and posterior cerebrovascular territories. The seven CM patients with ASCI were significantly older and had a higher rate of DM and previous stroke than the other 30 CM adults without ASCI. They also had a higher incidence of consciousness disturbance at presentation and had a poor prognosis. ASCI was found in 18.9% (7/37) of HIV-negative CM adults. Serial MRI follow-up studies may allow a better delineation of ASCI in this specific group of infectious disease and multiple lacunar infarctions was the most common type. Older in age and presence of DM and previous stroke were the significant underlying conditions. CM patients with ASCI also had a poor therapeutic outcome.

  12. Rule-based energy management strategies for hybrid vehicles

    NARCIS (Netherlands)

    Hofman, T.; Druten, van R.M.; Serrarens, A.F.A.; Steinbuch, M.

    2007-01-01

    Int. J. of Electric and Hybrid Vehicles (IJEHV), The highest control layer of a (hybrid) vehicular drive train is termed the Energy Management Strategy (EMS). In this paper an overview of different control methods is given and a new rule-based EMS is introduced based on the combination of Rule-Based

  13. Research on Fault Diagnosis Method Based on Rule Base Neural Network

    Directory of Open Access Journals (Sweden)

    Zheng Ni

    2017-01-01

    Full Text Available The relationship between fault phenomenon and fault cause is always nonlinear, which influences the accuracy of fault location. And neural network is effective in dealing with nonlinear problem. In order to improve the efficiency of uncertain fault diagnosis based on neural network, a neural network fault diagnosis method based on rule base is put forward. At first, the structure of BP neural network is built and the learning rule is given. Then, the rule base is built by fuzzy theory. An improved fuzzy neural construction model is designed, in which the calculated methods of node function and membership function are also given. Simulation results confirm the effectiveness of this method.

  14. Do third-party plans really pay for CVS care?

    Science.gov (United States)

    Soden, Richard

    2002-04-01

    Until specific CPT and ICD-9 codes are created and approved for CVS, and until there is uniform agreement that CVS is a true medical anomaly (or not), each practitioner will have to decide on how to bill for the signs and symptoms of Computer Vision Syndrome. If the practitioner chooses to view CVS as a medical problem, then the same guidelines and rules for all other patients should be followed with appropriate documentation using CPT and ICD-9 coding. If the practitioner chooses to consider CVS solely as an optical problem, this is a "noncovered" service and the patient or any applicable optical plan will be responsible for payment. One final note: each practitioner who tests for CVS will also have to determine if there is a separate fee for CVS testing. If the practitioner considers CVS to be a medical problem, it may be applicable to include testing for Computer Vision Syndrome as an incidental test to the medical office visit. If the practitioner chooses to consider CVS to be purely an optical problem, it may be appropriate to add an appropriate charge to the noncovered examination. Whatever the decision is, there must be consistency from patient to patient.

  15. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  16. Horizontal and Vertical Rule Bases Method in Fuzzy Controllers

    Directory of Open Access Journals (Sweden)

    Sadegh Aminifar

    2013-01-01

    Full Text Available Concept of horizontal and vertical rule bases is introduced. Using this method enables the designers to look for main behaviors of system and describes them with greater approximations. The rules which describe the system in first stage are called horizontal rule base. In the second stage, the designer modulates the obtained surface by describing needed changes on first surface for handling real behaviors of system. The rules used in the second stage are called vertical rule base. Horizontal and vertical rule bases method has a great roll in easing of extracting the optimum control surface by using too lesser rules than traditional fuzzy systems. This research involves with control of a system with high nonlinearity and in difficulty to model it with classical methods. As a case study for testing proposed method in real condition, the designed controller is applied to steaming room with uncertain data and variable parameters. A comparison between PID and traditional fuzzy counterpart and our proposed system shows that our proposed system outperforms PID and traditional fuzzy systems in point of view of number of valve switching and better surface following. The evaluations have done both with model simulation and DSP implementation.

  17. A numerical similarity approach for using retired Current Procedural Terminology (CPT) codes for electronic phenotyping in the Scalable Collaborative Infrastructure for a Learning Health System (SCILHS).

    Science.gov (United States)

    Klann, Jeffrey G; Phillips, Lori C; Turchin, Alexander; Weiler, Sarah; Mandl, Kenneth D; Murphy, Shawn N

    2015-12-11

    Interoperable phenotyping algorithms, needed to identify patient cohorts meeting eligibility criteria for observational studies or clinical trials, require medical data in a consistent structured, coded format. Data heterogeneity limits such algorithms' applicability. Existing approaches are often: not widely interoperable; or, have low sensitivity due to reliance on the lowest common denominator (ICD-9 diagnoses). In the Scalable Collaborative Infrastructure for a Learning Healthcare System (SCILHS) we endeavor to use the widely-available Current Procedural Terminology (CPT) procedure codes with ICD-9. Unfortunately, CPT changes drastically year-to-year - codes are retired/replaced. Longitudinal analysis requires grouping retired and current codes. BioPortal provides a navigable CPT hierarchy, which we imported into the Informatics for Integrating Biology and the Bedside (i2b2) data warehouse and analytics platform. However, this hierarchy does not include retired codes. We compared BioPortal's 2014AA CPT hierarchy with Partners Healthcare's SCILHS datamart, comprising three-million patients' data over 15 years. 573 CPT codes were not present in 2014AA (6.5 million occurrences). No existing terminology provided hierarchical linkages for these missing codes, so we developed a method that automatically places missing codes in the most specific "grouper" category, using the numerical similarity of CPT codes. Two informaticians reviewed the results. We incorporated the final table into our i2b2 SCILHS/PCORnet ontology, deployed it at seven sites, and performed a gap analysis and an evaluation against several phenotyping algorithms. The reviewers found the method placed the code correctly with 97 % precision when considering only miscategorizations ("correctness precision") and 52 % precision using a gold-standard of optimal placement ("optimality precision"). High correctness precision meant that codes were placed in a reasonable hierarchal position that a reviewer

  18. An XML-Based Manipulation and Query Language for Rule-Based Information

    Science.gov (United States)

    Mansour, Essam; Höpfner, Hagen

    Rules are utilized to assist in the monitoring process that is required in activities, such as disease management and customer relationship management. These rules are specified according to the application best practices. Most of research efforts emphasize on the specification and execution of these rules. Few research efforts focus on managing these rules as one object that has a management life-cycle. This paper presents our manipulation and query language that is developed to facilitate the maintenance of this object during its life-cycle and to query the information contained in this object. This language is based on an XML-based model. Furthermore, we evaluate the model and language using a prototype system applied to a clinical case study.

  19. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    Science.gov (United States)

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  20. Ocean circulation code on machine connection

    International Nuclear Information System (INIS)

    Vitart, F.

    1993-01-01

    This work is part of a development of a global climate model based on a coupling between an ocean model and an atmosphere model. The objective was to develop this global model on a massively parallel machine (CM2). The author presents the OPA7 code (equations, boundary conditions, equation system resolution) and parallelization on the CM2 machine. CM2 data structure is briefly evoked, and two tests are reported (on a flat bottom basin, and a topography with eight islands). The author then gives an overview of studies aimed at improving the ocean circulation code: use of a new state equation, use of a formulation of surface pressure, use of a new mesh. He reports the study of the use of multi-block domains on CM2 through advection tests, and two-block tests

  1. Fuzzy rule-based model for hydropower reservoirs operation

    Energy Technology Data Exchange (ETDEWEB)

    Moeini, R.; Afshar, A.; Afshar, M.H. [School of Civil Engineering, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2011-02-15

    Real-time hydropower reservoir operation is a continuous decision-making process of determining the water level of a reservoir or the volume of water released from it. The hydropower operation is usually based on operating policies and rules defined and decided upon in strategic planning. This paper presents a fuzzy rule-based model for the operation of hydropower reservoirs. The proposed fuzzy rule-based model presents a set of suitable operating rules for release from the reservoir based on ideal or target storage levels. The model operates on an 'if-then' principle, in which the 'if' is a vector of fuzzy premises and the 'then' is a vector of fuzzy consequences. In this paper, reservoir storage, inflow, and period are used as premises and the release as the consequence. The steps involved in the development of the model include, construction of membership functions for the inflow, storage and the release, formulation of fuzzy rules, implication, aggregation and defuzzification. The required knowledge bases for the formulation of the fuzzy rules is obtained form a stochastic dynamic programming (SDP) model with a steady state policy. The proposed model is applied to the hydropower operation of ''Dez'' reservoir in Iran and the results are presented and compared with those of the SDP model. The results indicate the ability of the method to solve hydropower reservoir operation problems. (author)

  2. An algorithm for rule-in and rule-out of acute myocardial infarction using a novel troponin I assay.

    Science.gov (United States)

    Lindahl, Bertil; Jernberg, Tomas; Badertscher, Patrick; Boeddinghaus, Jasper; Eggers, Kai M; Frick, Mats; Rubini Gimenez, Maria; Linder, Rickard; Ljung, Lina; Martinsson, Arne; Melki, Dina; Nestelberger, Thomas; Rentsch, Katharina; Reichlin, Tobias; Sabti, Zaid; Schubera, Marie; Svensson, Per; Twerenbold, Raphael; Wildi, Karin; Mueller, Christian

    2017-01-15

    To derive and validate a hybrid algorithm for rule-out and rule-in of acute myocardial infarction based on measurements at presentation and after 2 hours with a novel cardiac troponin I (cTnI) assay. The algorithm was derived and validated in two cohorts (605 and 592 patients) from multicentre studies enrolling chest pain patients presenting to the emergency department (ED) with onset of last episode within 12 hours. The index diagnosis and cardiovascular events up to 30 days were adjudicated by independent reviewers. In the validation cohort, 32.6% of the patients were ruled out on ED presentation, 6.1% were ruled in and 61.3% remained undetermined. A further 22% could be ruled out and 9.8% ruled in, after 2 hours. In total, 54.6% of the patients were ruled out with a negative predictive value (NPV) of 99.4% (95% CI 97.8% to 99.9%) and a sensitivity of 97.7% (95% CI 91.9% to 99.7%); 15.8% were ruled in with a positive predictive value (PPV) of 74.5% (95% CI 64.8% to 82.2%) and a specificity of 95.2% (95% CI 93.0% to 96.9%); and 29.6% remained undetermined after 2 hours. No patient in the rule-out group died during the 30-day follow-up in the two cohorts. This novel two-step algorithm based on cTnI measurements enabled just over a third of the patients with acute chest pain to be ruled in or ruled out already at presentation and an additional third after 2 hours. This strategy maximises the speed of rule-out and rule-in while maintaining a high NPV and PPV, respectively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Technical design report for the upgrade of the ICD for D-Zero Run II

    International Nuclear Information System (INIS)

    Sawyer, L.; De, K.; Draper, P.; Gallas, E.; Li, J.; Sosebee, M.; Stephens, R.W.; White, A.

    1998-01-01

    The Inter Cryostat Detector (ICD) used in Run I of the D0 Experiment will be inoperable in the central, high magnetic field planned for Run II. In Run I, the ICD enhanced the hermeticity and uniformity of the D0 calorimeter system, improving both missing transverse energy and jet energy resolution. The goals for the Run II ICD are the same. In this document, the physics arguments for maintaining the ICD are presented, followed by a detailed description of the planned design changes, prototype tests, construction, installation, and commissioning of the device for the Run II D0 detector. Estimates of costs and schedule can be found on //DOSERVER2/Operations/Upgrade Project/ subareas available via DZERO's WinFrame Program Manager. This detector is not intended to provide any ''L0'' capabilities (for luminosity monitoring), or to provide any EM coverage in the intermediate region, or to provide additional coverage in the intermediate regions, unlike previous upgrades proposed in this detector region. The ICD upgrade described here maintains most of the Run I capabilities in a high magnetic field environment

  4. Revisiting Desensitization and Allergen Immunotherapy Concepts for the International Classification of Diseases (ICD)-11.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises A; Papadopoulos, Nikolaos G; Sanchez-Borges, Mario; Rosenwasser, Lanny J; Bousquet, Jean; Pawankar, Ruby; Sisul, Juan Carlos; Cepeda, Alfonso Mario; Li, James; Muraro, Antonella; Fineman, Stanley; Sublett, James L; Katelaris, Constance H; Chang, Yoon-Seok; Moon, Hee-Bom; Casale, Thomas; Demoly, Pascal

    2016-01-01

    Allergy and hypersensitivity intervention management procedures, such as desensitization and/or tolerance induction and immunotherapy, have not been pondered up to now in the content of International Classification of Diseases (ICD) context because the focus has been on prioritizing the condition implementations. Tremendous efforts have been devoted to implementing allergic and hypersensitivity conditions in the forthcoming ICD-11. However, we consider that it is crucial now to have nomenclature and classification universally accepted for these procedures to be able to provide scientifically consistent proposals into the new ICD-11 platform for the best practice parameters of our specialty. With the aim of promoting a harmonized comprehension and aligning it with the ICD-11 revision, we have reviewed the definitions and concepts currently used for desensitization and/or tolerance induction and immunotherapy. We strongly believe that this review is a key instrument to support the allergy specialty identity into the ICD-11 framework and serves as a platform to perform positive quality improvement in clinical practice. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  5. Epidemiological studies on syncope--a register based approach

    DEFF Research Database (Denmark)

    Ruwald, Martin Huth

    2013-01-01

    of the patients play an essential role. In epidemiology these factors have major impact on the outcome of the patients. Until recently, even the definition of syncope, differed from one study to another which has made literature reviews difficult. Traditionally the data on epidemiology of syncope has been taken......: 1) the use, validity and accuracy of the ICD-10 diagnosis of syncope R55.9 in the National Patient Registry for the use of this diagnosis in the epidemiology of syncope, 2) diagnostics used and etiology of a random selection of patients who had a discharge diagnosis of R55.9, 3) the incidence...... thesis demonstrated that the ICD-10 discharge diagnosis could reliably identify a cohort of patients admitted for syncope and that the discharge code carried a high number of unexplained cases despite use of numerous tests. The last studies showed that syncope is a common cause for hospital contact...

  6. Gender Incongruence of Adolescence and Adulthood: Acceptability and Clinical Utility of the World Health Organization’s Proposed ICD-11 Criteria

    Science.gov (United States)

    Beek, Titia F.; Cohen-Kettenis, Peggy T.; Bouman, Walter P.; de Vries, Annelou L. C.; Steensma, Thomas D.; Witcomb, Gemma L.; Arcelus, Jon; Richards, Christina; Elaut, Els; Kreukels, Baudewijntje P. C.

    2016-01-01

    The World Health Organization (WHO) is currently updating the tenth version of their diagnostic tool, the International Classification of Diseases (ICD, WHO, 1992). Changes have been proposed for the diagnosis of Transsexualism (ICD-10) with regard to terminology, placement and content. The aim of this study was to gather the opinions of transgender individuals (and their relatives/partners) and clinicians in the Netherlands, Flanders (Belgium) and the United Kingdom regarding the proposed changes and the clinical applicability and utility of the ICD-11 criteria of ‘Gender Incongruence of Adolescence and Adulthood’ (GIAA). A total of 628 participants were included in the study: 284 from the Netherlands (45.2%), 8 from Flanders (Belgium) (1.3%), and 336 (53.5%) from the UK. Most participants were transgender people (or their partners/relatives) (n = 522), 89 participants were healthcare providers (HCPs) and 17 were both healthcare providers and (partners/relatives of) transgender people. Participants completed an online survey developed for this study. Most participants were in favor of the proposed diagnostic term of ‘Gender Incongruence’ and thought that this was an improvement on the ICD-10 diagnostic term of ‘Transsexualism’. Placement in a separate chapter dealing with Sexual- and Gender-related Health or as a Z-code was preferred by many and only a small number of participants stated that this diagnosis should be excluded from the ICD-11. In the UK, most transgender participants thought there should be a diagnosis related to being trans. However, if it were to be removed from the chapter on “psychiatric disorders”, many transgender respondents indicated that they would prefer it to be removed from the ICD in its entirety. There were no large differences between the responses of the transgender participants (or their partners and relatives) and HCPs. HCPs were generally positive about the GIAA diagnosis; most thought the diagnosis was clearly

  7. Application of SN and Monte Carlo codes to the SHEBA critical assemblies

    International Nuclear Information System (INIS)

    O'Dell, R.D.

    1993-01-01

    The Solution High-Energy Burst Assembly (SHEBA) at Los Alamos is a low-enriched (4.95 wt. %) aqueous uranyl fluoride solution critical assembly. There are two SHEBA configurations, both consisting of right circular cylinders with a central control rod. The first configuration, hereafter called the old SHEBA, had a fuel solution diameter of 54.6 cm and a measured critical solution height of 36.5 cm. An improved modification, hereafter called the new SHEBA, has a fuel solution diameter of 48.9 cm but since it is not yet operational, the critical solution height has not yet been measured. In this presentation the application of the discrete-ordinates (S N ) code TWODANT using Hansen-Roach cross sections and the MCNP Monte Carlo code using continuous-energy cross sections for calculating the critical solution heights for both the old and new SHEBA assemblies is described. The code's predictions are compared and it is shown that a single calculation with a standard computer code may yield misleading results, especially when using a Monte Carlo code

  8. Electromagnetic Interference from Swimming Pool Generator Current Causing Inappropriate ICD Discharges

    Directory of Open Access Journals (Sweden)

    Edward Samuel Roberto

    2017-01-01

    Full Text Available Electromagnetic interference (EMI includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation. This is a unique case of extracardiac EMI by alternating current leakage from a submerged motor used to recycle chlorinated water, resulting in false rhythm detection and inappropriate ICD discharge. A 31-year-old female with arrhythmogenic right ventricular cardiomyopathy and Medtronic dual-chamber ICD placement presented after several inappropriate ICD shocks at the public swimming pool. Patient had never received prior shocks and device was appropriate at all regular follow-ups. Intracardiac electrograms revealed unique, high-frequency signals at exactly 120 msec suggestive of EMI from a strong external source of alternating current. Electrical artifact was incorrectly sensed as a ventricular arrhythmia which resulted in discharge. ICD parameters including sensing, pacing thresholds, and impedance were all normal suggesting against device malfunction. With device failure and intracardiac sources excluded, EMI was therefore strongly suspected. Avoidance of EMI source brought complete resolution with no further inappropriate shocks. After exclusion of intracardiac interference, device malfunction, and abnormal settings, extracardiac etiologies such as EMI must be thoughtfully considered and excluded. Elimination of inappropriate shocks is to “first, do no harm.”

  9. Trellises and Trellis-Based Decoding Algorithms for Linear Block Codes

    Science.gov (United States)

    Lin, Shu

    1998-01-01

    sectionalization of trellises. Chapter 7 discusses trellis decomposition and subtrellises for low-weight codewords. Chapter 8 first presents well known methods for constructing long powerful codes from short component codes or component codes of smaller dimensions, and then provides methods for constructing their trellises which include Shannon and Cartesian product techniques. Chapter 9 deals with convolutional codes, puncturing, zero-tail termination and tail-biting.Chapters 10 through 13 present various trellis-based decoding algorithms, old and new. Chapter 10 first discusses the application of the well known Viterbi decoding algorithm to linear block codes, optimum sectionalization of a code trellis to minimize computation complexity, and design issues for IC (integrated circuit) implementation of a Viterbi decoder. Then it presents a new decoding algorithm for convolutional codes, named Differential Trellis Decoding (DTD) algorithm. Chapter 12 presents a suboptimum reliability-based iterative decoding algorithm with a low-weight trellis search for the most likely codeword. This decoding algorithm provides a good trade-off between error performance and decoding complexity. All the decoding algorithms presented in Chapters 10 through 12 are devised to minimize word error probability. Chapter 13 presents decoding algorithms that minimize bit error probability and provide the corresponding soft (reliability) information at the output of the decoder. Decoding algorithms presented are the MAP (maximum a posteriori probability) decoding algorithm and the Soft-Output Viterbi Algorithm (SOVA) algorithm. Finally, the minimization of bit error probability in trellis-based MLD is discussed.

  10. Mortality from idiopathic pulmonary fibrosis: a temporal trend analysis in Brazil, 1979-2014

    OpenAIRE

    Algranti, Eduardo; Saito, Cézar Akiyoshi; Silva, Diego Rodrigues Mendonça e; Carneiro, Ana Paula Scalia; Bussacos, Marco Antonio

    2017-01-01

    ABSTRACT Objective: To analyze mortality from idiopathic pulmonary fibrosis (IPF) in Brazil over the period 1979-2014. Methods: Microdata were extracted from the Brazilian National Ministry of Health Mortality Database. Only deaths for which the underlying cause was coded as International Classification of Diseases version 9 (ICD-9) 515 or 516.3 (until 1995) or as ICD version 10 (ICD-10) J84.1 (from 1996 onward) were included in our analysis. Standardized mortality rates were calculated for...

  11. Association between socioeconomic factors and ICD implantation in a publicly financed health care system

    DEFF Research Database (Denmark)

    Winther-Jensen, Matilde; Hassager, Christian; Lassen, Jens Flensted

    2017-01-01

    Aims: For patients surviving out-of-hospital cardiac arrest (OHCA) with a shockable rhythm, implantable cardioverter defibrillator (ICD) is recommended for non-reversible causes of arrest. We aimed to determine factors associated with implantation of ICD and survival in patients surviving non...... admission. Association to ICD implantation during index admission was analysed in logistic regression, survival was assessed using Cox regression. Implantable cardioverter defibrillator implantation increased during the study period [odds ratio (OR) 1-year increase: 1.04, 95% confidence intervals (95% CI...

  12. Analysis of Rules for Islamic Inheritance Law in Indonesia Using Hybrid Rule Based Learning

    Science.gov (United States)

    Khosyi'ah, S.; Irfan, M.; Maylawati, D. S.; Mukhlas, O. S.

    2018-01-01

    Along with the development of human civilization in Indonesia, the changes and reform of Islamic inheritance law so as to conform to the conditions and culture cannot be denied. The distribution of inheritance in Indonesia can be done automatically by storing the rule of Islamic inheritance law in the expert system. In this study, we analyze the knowledge of experts in Islamic inheritance in Indonesia and represent it in the form of rules using rule-based Forward Chaining (FC) and Davis-Putman-Logemann-Loveland (DPLL) algorithms. By hybridizing FC and DPLL algorithms, the rules of Islamic inheritance law in Indonesia are clearly defined and measured. The rules were conceptually validated by some experts in Islamic laws and informatics. The results revealed that generally all rules were ready for use in an expert system.

  13. Numerical analysis of reflood simulation based on a mechanistic, best-estimate, approach by KREWET code

    International Nuclear Information System (INIS)

    Chun, Moon-Hyun; Jeong, Eun-Soo

    1983-01-01

    A new computer code entitled KREWET has been developed in an effort to improve the accuracy and applicability of the existing reflood heat transfer simulation computer code. Sample calculations for temperature histories and heat transfer coefficient are made using KREWET code and the results are compared with the predictions of REFLUX, QUEN1D, and the PWR-FLECHT data for various conditions. These show favourable agreement in terms of clad temperature versus time. For high flooding rates (5-15cm/sec) and high pressure (∼413 Kpa), reflood predictions are reasonably well predicted by KREWET code as well as with other codes. For low flooding rates (less than ∼4cm/sec) and low pressure (∼138Kpa), predictions show considerable error in evaluating the rewet position versus time. This observation is common to all the codes examined in the present work

  14. Numerical analysis for reflood simulation based on a mechanistic, best-estimate, approach by KREWET code

    International Nuclear Information System (INIS)

    Chun, M.-H.; Jeong, E.-S.

    1983-01-01

    A new computer code entitled KREWET has been developed in an effort to improve the accuracy and applicability of the existing reflood heat transfer simulation computer code. Sample calculations for temperature histories and heat transfer coefficient are made using KREWET code and the results are compared with the predictions of REFLUX, QUENID, and the PWR-FLECHT data for various conditions. These show favorable agreement in terms of clad temperature versus time. For high flooding rates (5-15cm/sec) and high pressure (approx. =413 Kpa), reflood predictions are reasonably well predicted by KREWET code as well as with other codes. For low flooding rates (less than approx. =4cm/sec) and low pressure (approx. =138 Kpa), predictions show considerable error in evaluating the rewet position versus time. This observation is common to all the codes examined in the present work

  15. Proposed declassification of disease categories related to sexual orientation in the International Statistical Classification of Diseases and Related Health Problems (ICD-11).

    Science.gov (United States)

    Cochran, Susan D; Drescher, Jack; Kismödi, Eszter; Giami, Alain; García-Moreno, Claudia; Atalla, Elham; Marais, Adele; Vieira, Elisabeth Meloni; Reed, Geoffrey M

    2014-09-01

    The World Health Organization is developing the 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11), planned for publication in 2017. The Working Group on the Classification of Sexual Disorders and Sexual Health was charged with reviewing and making recommendations on disease categories related to sexuality in the chapter on mental and behavioural disorders in the 10th revision (ICD-10), published in 1990. This chapter includes categories for diagnoses based primarily on sexual orientation even though ICD-10 states that sexual orientation alone is not a disorder. This article reviews the scientific evidence and clinical rationale for continuing to include these categories in the ICD. A review of the evidence published since 1990 found little scientific interest in these categories. In addition, the Working Group found no evidence that they are clinically useful: they neither contribute to health service delivery or treatment selection nor provide essential information for public health surveillance. Moreover, use of these categories may create unnecessary harm by delaying accurate diagnosis and treatment. The Working Group recommends that these categories be deleted entirely from ICD-11. Health concerns related to sexual orientation can be better addressed using other ICD categories.

  16. Creep design rules in french ''RCC-MR'' code

    International Nuclear Information System (INIS)

    Roche, H.

    1986-04-01

    In this paper, four points enlightening the originality of the ''RCC-MR'' analysis rules in the creep range will be discussed. The three first points will concern elastic analysis, the fourth one materials data. The rules given in this paper are applicable for class 1 components and level A conditions. They are given by way of illustration in a simplified form

  17. Acute/subacute cerebral infarction (ASCI in HIV-negative adults with cryptococcal meningoencephalitis (CM: a MRI-based follow-up study and a clinical comparison to HIV-negative CM adults without ASCI

    Directory of Open Access Journals (Sweden)

    Chang Chiung-Chih

    2011-01-01

    Full Text Available Abstract Background Acute/subacute cerebral infarction (ASCI in HIV-negative cryptococcal meningoencephalitis (CM adults has rarely been examined by a series of MRI-based follow-up study. We studied a series of MRI follow-up study of CM adults and compared the clinical characters of those with ASCI and those without ASCI. Methods The clinical characteristics and a series of brain MRI findings of seven CM adults with ASCI were enrolled for analysis. The clinical characteristics of another 30 HIV-negative CM adults who did not have ASCI were also included for a comparative analysis. Results The seven HIV-negative CM adults with ASCI were four men and three women, aged 46-78 years. Lacunar infarction was the type of ASCI, and 86% (6/7 of the ACSI were multiple infarctions distributed in both the anterior and posterior cerebrovascular territories. The seven CM patients with ASCI were significantly older and had a higher rate of DM and previous stroke than the other 30 CM adults without ASCI. They also had a higher incidence of consciousness disturbance at presentation and had a poor prognosis. Conclusion ASCI was found in 18.9% (7/37 of HIV-negative CM adults. Serial MRI follow-up studies may allow a better delineation of ASCI in this specific group of infectious disease and multiple lacunar infarctions was the most common type. Older in age and presence of DM and previous stroke were the significant underlying conditions. CM patients with ASCI also had a poor therapeutic outcome.

  18. Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems

    Science.gov (United States)

    Hinchey, Mike; Rash, James; Erickson, John; Gracanin, Denis; Rouff, Chris

    2010-01-01

    Mathematically sound techniques are used to view a knowledge-based system (KBS) as a set of processes executing in parallel and being enabled in response to specific rules being fired. The set of processes can be manipulated, examined, analyzed, and used in a simulation. The tool that embodies this technology may warn developers of errors in their rules, but may also highlight rules (or sets of rules) in the system that are underspecified (or overspecified) and need to be corrected for the KBS to operate as intended. The rules embodied in a KBS specify the allowed situations, events, and/or results of the system they describe. In that sense, they provide a very abstract specification of a system. The system is implemented through the combination of the system specification together with an appropriate inference engine, independent of the algorithm used in that inference engine. Viewing the rule base as a major component of the specification, and choosing an appropriate specification notation to represent it, reveals how additional power can be derived from an approach to the knowledge-base system that involves analysis, simulation, and verification. This innovative approach requires no special knowledge of the rules, and allows a general approach where standardized analysis, verification, simulation, and model checking techniques can be applied to the KBS.

  19. Learning and coding in biological neural networks

    Science.gov (United States)

    Fiete, Ila Rani

    How can large groups of neurons that locally modify their activities learn to collectively perform a desired task? Do studies of learning in small networks tell us anything about learning in the fantastically large collection of neurons that make up a vertebrate brain? What factors do neurons optimize by encoding sensory inputs or motor commands in the way they do? In this thesis I present a collection of four theoretical works: each of the projects was motivated by specific constraints and complexities of biological neural networks, as revealed by experimental studies; together, they aim to partially address some of the central questions of neuroscience posed above. We first study the role of sparse neural activity, as seen in the coding of sequential commands in a premotor area responsible for birdsong. We show that the sparse coding of temporal sequences in the songbird brain can, in a network where the feedforward plastic weights must translate the sparse sequential code into a time-varying muscle code, facilitate learning by minimizing synaptic interference. Next, we propose a biologically plausible synaptic plasticity rule that can perform goal-directed learning in recurrent networks of voltage-based spiking neurons that interact through conductances. Learning is based on the correlation of noisy local activity with a global reward signal; we prove that this rule performs stochastic gradient ascent on the reward. Thus, if the reward signal quantifies network performance on some desired task, the plasticity rule provably drives goal-directed learning in the network. To assess the convergence properties of the learning rule, we compare it with a known example of learning in the brain. Song-learning in finches is a clear example of a learned behavior, with detailed available neurophysiological data. With our learning rule, we train an anatomically accurate model birdsong network that drives a sound source to mimic an actual zebrafinch song. Simulation and

  20. State of the art of ICD programming

    DEFF Research Database (Denmark)

    Mastenbroek, M H; Pedersen, Susanne S.; Versteeg, H

    2014-01-01

    , were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming...

  1. Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.

    Science.gov (United States)

    Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun

    2016-01-01

    Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.

  2. LSB-based Steganography Using Reflected Gray Code for Color Quantum Images

    Science.gov (United States)

    Li, Panchi; Lu, Aiping

    2018-02-01

    At present, the classical least-significant-bit (LSB) based image steganography has been extended to quantum image processing. For the existing LSB-based quantum image steganography schemes, the embedding capacity is no more than 3 bits per pixel. Therefore, it is meaningful to study how to improve the embedding capacity of quantum image steganography. This work presents a novel LSB-based steganography using reflected Gray code for colored quantum images, and the embedding capacity of this scheme is up to 4 bits per pixel. In proposed scheme, the secret qubit sequence is considered as a sequence of 4-bit segments. For the four bits in each segment, the first bit is embedded in the second LSB of B channel of the cover image, and and the remaining three bits are embedded in LSB of RGB channels of each color pixel simultaneously using reflected-Gray code to determine the embedded bit from secret information. Following the transforming rule, the LSB of stego-image are not always same as the secret bits and the differences are up to almost 50%. Experimental results confirm that the proposed scheme shows good performance and outperforms the previous ones currently found in the literature in terms of embedding capacity.

  3. 78 FR 70558 - Review of Proposed Changes with ICD-10-CM/PCS; Conversion of Quality IndicatorsTM

    Science.gov (United States)

    2013-11-26

    ... new code sets requires involvement of many stakeholders; measure developers should solicit comments... reporting to enable consumers to make more informed choices about their sites of care, public reporting to reward favorable outcomes and encourage changes in provider behavior, and information to be used by...

  4. Wearable cardioverter defibrillator: A life vest till the life boat (ICD arrives

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2014-01-01

    Full Text Available It is well established that implantable cardioverter defibrillator (ICD is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation of an ICD while the patient can still be at a risk of demise due to a life threatening ventricular arrhythmia. There could also be a temporary indication for protection while explanting an infected ICD system. The wearable cardioverter defibrillator (WCD is a device which comes to the rescue in such situations. In this brief review, we discuss the historical aspects of the development of a WCD, technical aspects as well as the clinical trial data and real world scenario of its use.

  5. ASME nuclear codes and standards: Recent technical initiatives

    International Nuclear Information System (INIS)

    Feigel, R. E.

    1995-01-01

    Although nuclear power construction is currently in a hiatus in the US, ASME and its volunteer committees remain committed to continual improvements in the technical requirements in its nuclear codes. This paper provides an overview of several significant recent revisions to ASME' s nuclear codes. Additionally, other important initiatives currently being addressed by ASME committees will be described. With the largest population of operating light water nuclear plants in the world and worldwide use of its nuclear codes, ASME continues to support technical advancements in its nuclear codes and standards. While revisions of various magnitude are an ongoing process, several recent revisions embody significant changes based on state of the art design philosophy and substantial industry experience. In the design area, a significant revisions has recently been approved which will significantly reduce conservatisms in seismic piping design as well as provide simplified design rules. Major revisions have also been made to the requirements for nuclear material manufacturers and suppliers, which should result in clearer understanding of this difficult administrative area of the code. In the area of Section XI inservice rules, substantial studies are underway to investigate the application of probabilistic, risked based inspection in lieu of the current deterministic inspection philosophy. While much work still is required in this area, it is an important potential application of the emerging field of risk based inspection

  6. Deriving ICD-11 personality disorder domains from dsm-5 traits: initial attempt to harmonize two diagnostic systems.

    Science.gov (United States)

    Bach, B; Sellbom, M; Kongerslev, M; Simonsen, E; Krueger, R F; Mulder, R

    2017-07-01

    The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. We examined (i) whether designated DSM-5 trait facets can be used to describe the proposed ICD-11 trait domains, and (ii) how these ICD-11 trait features are hierarchically organized. A mixed Danish derivation sample (N = 1541) of 615 psychiatric out-patients and 925 community participants along with a US replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized in the proposed ICD-11 five-domain structure as well as other recognizable higher-order models of personality and psychopathology. Model fits revealed that the five proposed ICD-11 personality disorder domains were satisfactorily resembled, and replicated in the independent US sample. The proposed ICD-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. The sign rule and beyond: boundary effects, flexibility, and noise correlations in neural population codes.

    Directory of Open Access Journals (Sweden)

    Yu Hu

    2014-02-01

    Full Text Available Over repeat presentations of the same stimulus, sensory neurons show variable responses. This "noise" is typically correlated between pairs of cells, and a question with rich history in neuroscience is how these noise correlations impact the population's ability to encode the stimulus. Here, we consider a very general setting for population coding, investigating how information varies as a function of noise correlations, with all other aspects of the problem - neural tuning curves, etc. - held fixed. This work yields unifying insights into the role of noise correlations. These are summarized in the form of theorems, and illustrated with numerical examples involving neurons with diverse tuning curves. Our main contributions are as follows. (1 We generalize previous results to prove a sign rule (SR - if noise correlations between pairs of neurons have opposite signs vs. their signal correlations, then coding performance will improve compared to the independent case. This holds for three different metrics of coding performance, and for arbitrary tuning curves and levels of heterogeneity. This generality is true for our other results as well. (2 As also pointed out in the literature, the SR does not provide a necessary condition for good coding. We show that a diverse set of correlation structures can improve coding. Many of these violate the SR, as do experimentally observed correlations. There is structure to this diversity: we prove that the optimal correlation structures must lie on boundaries of the possible set of noise correlations. (3 We provide a novel set of necessary and sufficient conditions, under which the coding performance (in the presence of noise will be as good as it would be if there were no noise present at all.

  8. Values of Kp Indices, Ap Indices, Cp Indices, C9 Indices, Sunspot Number, and 10.7 cm Flux

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data file consists of Kp indices, Ap indices, Cp indices, C9 indices, sunspot number, and 10.7 cm flux. The most often requested parameter of this file are the...

  9. Medical Admissions and Outcomes at Saint Paul's Hospital, Addis ...

    African Journals Online (AJOL)

    kim

    Diseases (ICD) coding system (9). Diseases were classified into communicable and non-communicable categories based on the definitions used by the WHO and the Centres for Disease Control and Prevention. (10, 11). Data entry, processing and analysis: Data were entered into and analysed using IBM SPSS Statistics.

  10. A hospital-wide clinical findings dictionary based on an extension of the International Classification of Diseases (ICD).

    Science.gov (United States)

    Bréant, C; Borst, F; Campi, D; Griesser, V; Momjian, S

    1999-01-01

    The use of a controlled vocabulary set in a hospital-wide clinical information system is of crucial importance for many departmental database systems to communicate and exchange information. In the absence of an internationally recognized clinical controlled vocabulary set, a new extension of the International statistical Classification of Diseases (ICD) is proposed. It expands the scope of the standard ICD beyond diagnosis and procedures to clinical terminology. In addition, the common Clinical Findings Dictionary (CFD) further records the definition of clinical entities. The construction of the vocabulary set and the CFD is incremental and manual. Tools have been implemented to facilitate the tasks of defining/maintaining/publishing dictionary versions. The design of database applications in the integrated clinical information system is driven by the CFD which is part of the Medical Questionnaire Designer tool. Several integrated clinical database applications in the field of diabetes and neuro-surgery have been developed at the HUG.

  11. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    Science.gov (United States)

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  12. Connecting clinical and actuarial prediction with rule-based methods.

    Science.gov (United States)

    Fokkema, Marjolein; Smits, Niels; Kelderman, Henk; Penninx, Brenda W J H

    2015-06-01

    Meta-analyses comparing the accuracy of clinical versus actuarial prediction have shown actuarial methods to outperform clinical methods, on average. However, actuarial methods are still not widely used in clinical practice, and there has been a call for the development of actuarial prediction methods for clinical practice. We argue that rule-based methods may be more useful than the linear main effect models usually employed in prediction studies, from a data and decision analytic as well as a practical perspective. In addition, decision rules derived with rule-based methods can be represented as fast and frugal trees, which, unlike main effects models, can be used in a sequential fashion, reducing the number of cues that have to be evaluated before making a prediction. We illustrate the usability of rule-based methods by applying RuleFit, an algorithm for deriving decision rules for classification and regression problems, to a dataset on prediction of the course of depressive and anxiety disorders from Penninx et al. (2011). The RuleFit algorithm provided a model consisting of 2 simple decision rules, requiring evaluation of only 2 to 4 cues. Predictive accuracy of the 2-rule model was very similar to that of a logistic regression model incorporating 20 predictor variables, originally applied to the dataset. In addition, the 2-rule model required, on average, evaluation of only 3 cues. Therefore, the RuleFit algorithm appears to be a promising method for creating decision tools that are less time consuming and easier to apply in psychological practice, and with accuracy comparable to traditional actuarial methods. (c) 2015 APA, all rights reserved).

  13. A comparison of DSM-5 and ICD-11 PTSD prevalence, comorbidity and disability: an analysis of the Ukrainian Internally Displaced Person's Mental Health Survey.

    Science.gov (United States)

    Shevlin, M; Hyland, P; Vallières, F; Bisson, J; Makhashvili, N; Javakhishvili, J; Shpiker, M; Roberts, B

    2018-02-01

    Recently, the American Psychiatric Association (DSM-5) and the World Health Organization (ICD-11) have both revised their formulation of post-traumatic stress disorder (PTSD). The primary aim of this study was to compare DSM-5 and ICD-11 PTSD prevalence and comorbidity rates, as well as the level of disability associated with each diagnosis. This study was based on a representative sample of adult Ukrainian internally displaced persons (IDPs: N = 2203). Post-traumatic stress disorder prevalence was assessed using the PTSD Checklist for DSM-5 and the International Trauma Questionnaire (ICD-11). Anxiety and depression were measured using the Generalized Anxiety Disorder Scale and the Patient Health Questionnaire-Depression. Disability was measured using the WHO Disability Assessment Schedule 2.0. The prevalence of DSM-5 PTSD (27.4%) was significantly higher than ICD-11 PTSD (21.0%), and PTSD rates for females were significantly higher using both criteria. ICD-11 PTSD was associated with significantly higher levels of disability and comorbidity. The ICD-11 diagnosis of PTSD appears to be particularly well suited to identifying those with clinically relevant levels of disability. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Structure of DSM-5 and ICD-11 personality domains in Iranian community sample.

    Science.gov (United States)

    Lotfi, Mozhgan; Bach, Bo; Amini, Mahdi; Simonsen, Erik

    2018-02-02

    Personality disorders (PD) have been deemed the most problematic diagnostic grouping in terms of validity and utility, which particularly applies to non-Western societies. The current study evaluated the structural validity of PD trait domains in the Diagnostic and Statistical Manual of Mental Disorders-5 (DSM-5) Section III and the proposed International Classification of Diseases-11 (ICD-11) in the Iranian population. Community-dwelling adults (n = 285; 66% women) were administered the Personality Inventory for DSM-5, whereas the proposed ICD-11 trait domains were delineated using an algorithm for Personality Inventory for DSM-5 trait facets. The five-factor organization and higher-order hierarchical structure of both models were examined using exploratory structural equation modelling analyses. The five-factor exploratory structural equation modelling loadings overall resembled international findings on DSM-5 Section III traits (including Psychoticism), whereas the ICD-11 five-factor structure aligned with the proposed ICD-11 domain features (including Anankastia). Additionally, we identified a hierarchical structure from one to five factors for both models that conceptually aligned with established models of personality and psychopathology. This study provided initial support for the structural validity of DSM-5 and ICD-11 PD trait models in Iranian culture. Future research warrants replication in larger samples and clinical populations. Copyright © 2018 John Wiley & Sons, Ltd. Copyright © 2018 John Wiley & Sons, Ltd.

  15. Comparison of some classification algorithms based on deterministic and nondeterministic decision rules

    KAUST Repository

    Delimata, Paweł

    2010-01-01

    We discuss two, in a sense extreme, kinds of nondeterministic rules in decision tables. The first kind of rules, called as inhibitory rules, are blocking only one decision value (i.e., they have all but one decisions from all possible decisions on their right hand sides). Contrary to this, any rule of the second kind, called as a bounded nondeterministic rule, can have on the right hand side only a few decisions. We show that both kinds of rules can be used for improving the quality of classification. In the paper, two lazy classification algorithms of polynomial time complexity are considered. These algorithms are based on deterministic and inhibitory decision rules, but the direct generation of rules is not required. Instead of this, for any new object the considered algorithms extract from a given decision table efficiently some information about the set of rules. Next, this information is used by a decision-making procedure. The reported results of experiments show that the algorithms based on inhibitory decision rules are often better than those based on deterministic decision rules. We also present an application of bounded nondeterministic rules in construction of rule based classifiers. We include the results of experiments showing that by combining rule based classifiers based on minimal decision rules with bounded nondeterministic rules having confidence close to 1 and sufficiently large support, it is possible to improve the classification quality. © 2010 Springer-Verlag.

  16. Small bowel volvulus in the adult populace of the United States: results from a population-based study.

    Science.gov (United States)

    Coe, Taylor M; Chang, David C; Sicklick, Jason K

    2015-08-01

    Small bowel volvulus is a rare entity in Western adults. Greater insight into epidemiology and outcomes may be gained from a national database inquiry. The Nationwide Inpatient Sample (1998 to 2010), a 20% stratified sample of United States hospitals, was retrospectively reviewed for small bowel volvulus cases (International Classification of Diseases, 9th Edition [ICD-9] code 560.2 excluding gastric/colonic procedures) in patients greater than or equal to 18 years old. There were 2,065,599 hospitalizations for bowel obstruction (ICD-9 560.x). Of those, there were 20,680 (1.00%) small bowel volvulus cases; 169 were attributable to intestinal malrotation. Most cases presented emergently (89.24%) and operative management was employed more frequently than nonoperative (65.21% vs 34.79%, P volvulus, our findings provide a robust representation of this rare cause of small bowel obstruction in American adults. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Orthogonal search-based rule extraction for modelling the decision to transfuse.

    Science.gov (United States)

    Etchells, T A; Harrison, M J

    2006-04-01

    Data from an audit relating to transfusion decisions during intermediate or major surgery were analysed to determine the strengths of certain factors in the decision making process. The analysis, using orthogonal search-based rule extraction (OSRE) from a trained neural network, demonstrated that the risk of tissue hypoxia (ROTH) assessed using a 100-mm visual analogue scale, the haemoglobin value (Hb) and the presence or absence of on-going haemorrhage (OGH) were able to reproduce the transfusion decisions with a joint specificity of 0.96 and sensitivity of 0.93 and a positive predictive value of 0.9. The rules indicating transfusion were: 1. ROTH > 32 mm and Hb 13 mm and Hb 38 mm, Hb < 102 g x l(-1) and OGH; 4. Hb < 78 g x l(-1).

  18. Subtypes of depressive episodes according to ICD-10

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel

    2003-01-01

    a period from 1994 to 1999 were identified. The risk of relapse leading to readmission and the risk of committing suicide were compared for patients discharged with an ICD-10 diagnosis of a single depressive episode with and without melancholic syndrome and for patients with and without psychotic symptoms......BACKGROUND: The long-term predictive ability of the ICD-10 subtypes of depression with melancholic syndrome and depression with psychosis has not been investigated. SAMPLING AND METHODS: All patients in Denmark who had a diagnosis of a single depressive episode at their first ever discharge during......, respectively. RESULTS: In all, 1,639 patients had a diagnosis of depressive episode without psychotic symptoms, 1,275 patients a diagnosis with psychotic symptoms, 293 a diagnosis without melancholic syndrome, and 248 a diagnosis with melancholic symptoms at first discharge. The risk of relapse leading...

  19. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  20. Online Dispatching Rules For Vehicle-Based Internal Transport Systems

    NARCIS (Netherlands)

    T. Le-Anh (Tuan); M.B.M. de Koster (René)

    2004-01-01

    textabstractOn-line vehicles dispatching rules are widely used in many facilities such as warehouses to control vehicles' movements. Single-attribute dispatching rules, which dispatch vehicles based on only one parameter, are used commonly. However, multi-attribute dispatching rules prove to be

  1. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead.

    Science.gov (United States)

    Lovelock, Joshua D; Premkumar, Ajay; Levy, Mathew R; Mengistu, Andenet; Hoskins, Michael H; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel R; Langberg, Jonathan J; Delurgio, David B

    2015-12-01

    St. Jude Riata/Riata ST defibrillator leads (St. Jude Medical, Sylmar, CA, USA) were recalled by the Food and Drug Administration in 2011 for an increased rate of failure. More than 227,000 leads were implanted and at least 79,000 patients still have active Riata leads. Studies have examined clinical predictors of lead failure in Riata leads, but none have addressed the effect of implantable cardioverter defibrillator (ICD) generator exchange on lead failure. The purpose of this study is to assess the effect of ICD generator exchange on the rate of electrical failure in the Riata lead at 1 year. A retrospective chart review was conducted in patients who underwent implantation of a Riata/Riata ST lead at one center. Patients with a functioning Riata lead (with/without externalized conductor) at the time of ICD exchange were compared to controls with Riata leads implanted for a comparable amount of time who did not undergo generator replacement. Riata leads were implanted in 1,042 patients prior to the recall and 153 of these patients underwent generator exchange without lead replacement. Conductor externalization was noted in 21.5% of Riata leads in the ICD exchange cohort, which was not different from the control group (19.2%; P = 0.32). Two leads failed in the first year after generator replacement (1.5%) which did not significantly differ from the control group (2.0%; P = 0.57). At change-out, 54% received a commanded shock (18.6 ± 0.9 J) that did not result in any change in the high-voltage lead impedance (46.1 ± 1.1 ohms). Conductor externalization was seen frequently in our cohort of patients. ICD generator exchange did not accelerate the rate of Riata lead failure at 1 year. Although both the control and the change-out cohorts failed at a rate much greater than nonrecalled leads, generator exchange did not appear to add to the problem. ©2015 Wiley Periodicals, Inc.

  2. WellnessRules: A Web 3.0 Case Study in RuleML-Based Prolog-N3 Profile Interoperation

    Science.gov (United States)

    Boley, Harold; Osmun, Taylor Michael; Craig, Benjamin Larry

    An interoperation study, WellnessRules, is described, where rules about wellness opportunities are created by participants in rule languages such as Prolog and N3, and translated within a wellness community using RuleML/XML. The wellness rules are centered around participants, as profiles, encoding knowledge about their activities conditional on the season, the time-of-day, the weather, etc. This distributed knowledge base extends FOAF profiles with a vocabulary and rules about wellness group networking. The communication between participants is organized through Rule Responder, permitting wellness-profile translation and distributed querying across engines. WellnessRules interoperates between rules and queries in the relational (Datalog) paradigm of the pure-Prolog subset of POSL and in the frame (F-logic) paradigm of N3. An evaluation of Rule Responder instantiated for WellnessRules revealed acceptable Web response times.

  3. Design rules and reality check for carbon-based ultracapacitors

    Science.gov (United States)

    Eisenmann, Erhard T.

    1995-04-01

    Design criteria for carbon-based Ultracapacitors have been determined for specified energy and power requirements, using the geometry of the components and such material properties as density, porosity and conductivity as parameters, while also considering chemical compatibility. This analysis shows that the weights of active and inactive components of the capacitor structure must be carefully balanced for maximum energy and power density. When applied to nonaqueous electrolytes, the design rules for a 5 Wh/kg device call for porous carbon with a specific capacitance of about 30 F/cu cm. This performance is not achievable with pure, electrostatic double layer capacitance. Double layer capacitance is only 5 to 30% of that observed in aqueous electrolyte. Tests also showed that nonaqueous electrolytes have a diminished capability to access micropores in activated carbon, in one case yielding a capacitance of less than 1 F/cu cm for carbon that had 100 F/cu cm in aqueous electrolyte. With negative results on nonaqueous electrolytes dominating the present study, the obvious conclusion is to concentrate on aqueous systems. Only aqueous double layer capacitors offer adequate electrostatic charging characteristics which is the basis for high power performance. There arc many opportunities for further advancing aqueous double layer capacitors, one being the use of highly activated carbon films, as opposed to powders, fibers and foams. While the manufacture of carbon films is still costly, and while the energy and power density of the resulting devices may not meet the optimistic goals that have been proposed, this technology could produce true double layer capacitors with significantly improved performance and large commercial potential.

  4. Diagnosing somatisation disorder (P75) in routine general practice using the International Classification of Primary Care.

    Science.gov (United States)

    Schaefert, Rainer; Laux, Gunter; Kaufmann, Claudia; Schellberg, Dieter; Bölter, Regine; Szecsenyi, Joachim; Sauer, Nina; Herzog, Wolfgang; Kuehlein, Thomas

    2010-09-01

    (i) To analyze general practitioners' diagnosis of somatisation disorder (P75) using the International Classification of Primary Care (ICPC)-2-E in routine general practice. (ii) To validate the distinctiveness of the ICD-10 to ICPC-2 conversion rule which maps ICD-10 dissociative/conversion disorder (F44) as well as half of the somatoform categories (F45.0-2) to P75 and codes the other half of these disorders (F45.3-9), including autonomic organ dysfunctions and pain syndromes, as symptom diagnoses plus a psychosocial code in a multiaxial manner. Cross-sectional analysis of routine data from a German research database comprising the electronic patient records of 32 general practitioners from 22 practices. For each P75 patient, control subjects matched for age, gender, and practice were selected from the 2007 yearly contact group (YCG) without a P75 diagnosis using a propensity-score algorithm that resulted in eight controls per P75 patient. Of the 49,423 patients in the YCG, P75 was diagnosed in 0.6% (302) and F45.3-9 in 1.8% (883) of cases; overall, somatisation syndromes were diagnosed in 2.4% of patients. The P75 coding pattern coincided with typical characteristics of severe, persistent medically unexplained symptoms (MUS). F45.3-9 was found to indicate moderate MUS that otherwise showed little clinical difference from P75. Pain syndromes exhibited an unspecific coding pattern. Mild and moderate MUS were predominantly recorded as symptom diagnoses. Psychosocial codes were rarely documented. ICPC-2 P75 was mainly diagnosed in cases of severe MUS. Multiaxial coding appears to be too complicated for routine primary care. Instead of splitting P75 and F45.3-9 diagnoses, it is proposed that the whole MUS spectrum should be conceptualized as a continuum model comprising categorizations of uncomplicated (mild) and complicated (moderate and severe) courses. Psychosocial factors require more attention. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  5. Personalization of Rule-based Web Services.

    Science.gov (United States)

    Choi, Okkyung; Han, Sang Yong

    2008-04-04

    Nowadays Web users have clearly expressed their wishes to receive personalized services directly. Personalization is the way to tailor services directly to the immediate requirements of the user. However, the current Web Services System does not provide any features supporting this such as consideration of personalization of services and intelligent matchmaking. In this research a flexible, personalized Rule-based Web Services System to address these problems and to enable efficient search, discovery and construction across general Web documents and Semantic Web documents in a Web Services System is proposed. This system utilizes matchmaking among service requesters', service providers' and users' preferences using a Rule-based Search Method, and subsequently ranks search results. A prototype of efficient Web Services search and construction for the suggested system is developed based on the current work.

  6. Sensitivity study on heuristic rules applied to the neutronic optimization of cells for BWR

    International Nuclear Information System (INIS)

    Gonzalez C, J.; Martin del Campo M, C.; Francois L, J.L.

    2004-01-01

    The objective of this work is to verify the validity of the heuristic rules that have been applied in the processes of radial optimization of fuel cells. It was examined the rule with respect to the accommodation of fuel in the corners of the cell and it became special attention on the influence of the position and concentration of those pellets with gadolinium in the reactivity of the cell and the safety parameters. The evaluation behaved on designed cells violating the heuristic rules. For both cases the cells were analyzed between infinite using the HELIOS code. Additionally, for the second case, it was behaved a stage more exhaustive where it was used one of the studied cells that it completed those safety parameters and of reactivity to generate the design of an assemble that was used to calculate with CM-PRESTO the behavior of the nucleus during three operation cycles. (Author)

  7. Tourette and tic disorders in ICD-11: standing at the diagnostic crossroads.

    Science.gov (United States)

    Woods, Douglas W; Thomsen, Per H

    2014-01-01

    This article reflects discussion by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. After reviewing the historical classification of tic disorders, this article discusses their placement in ICD-11. Existing problems with diagnostic labels and criteria, appropriate placement of the tic disorders category within the ICD-11 system, and pragmatic factors affecting classification are reviewed. The article ends with recommendations to (a) maintain consistency with the DSM-5 diagnostic labels for tic disorders, (b) add a minimum duration guideline for a provisional tic disorder diagnosis, (c) remove the multiple motor tic guideline for the diagnosis of Tourette disorder, and (d) co-parent the tic disorder diagnoses in the disorders of the nervous system and the mental and behavioral disorders categories, with secondary co-parenting in the obsessive-compulsive and related disorders and neurodevelopmental disorders sections.

  8. System Based Code: Principal Concept

    International Nuclear Information System (INIS)

    Yasuhide Asada; Masanori Tashimo; Masahiro Ueta

    2002-01-01

    This paper introduces a concept of the 'System Based Code' which has initially been proposed by the authors intending to give nuclear industry a leap of progress in the system reliability, performance improvement, and cost reduction. The concept of the System Based Code intends to give a theoretical procedure to optimize the reliability of the system by administrating every related engineering requirement throughout the life of the system from design to decommissioning. (authors)

  9. Frequency of ICD-10 psychiatric diagnosis in children with intellectual disability in Lahore, Pakistan & Caregivers Perspective.

    Science.gov (United States)

    Imran, Nazish; Azeem, Muhammad Waqar; Sattar, Ahsan; Bhatti, Mohammad Riaz

    2015-01-01

    Association between Intellectual disability (ID) and psychiatric disorders in children & adolescents is well established but there is a paucity of published studies from Pakistan on this topic. The main aim of the study was to assess the frequency of ICD-10 psychiatric diagnosis in the hospital outpatient sample of children with ID in Lahore, Pakistan as well as to find out which challenging behaviors, caregivers find difficult to manage in this setup. Socio-demographic information was collected, Wechsler Intelligence Scale for Children-Revised & ICD-10 diagnostic criteria was used to assess children (age range 6 - 16 years) with suspected ID along with identification of behaviors found to be difficult to manage by caregivers. 150 children were assessed with mean age of 10.7 years (males 70 %). Majority (72%) had mild ID while 18.7% and 9.3% had moderate and severe ID respectively. Thirty percent of children met the criteria for any psychiatric diagnosis, the most common being Oppositional Defiant Disorder (14%) and Hyperkinetic Disorders (10%). Verbal and physical aggression, school difficulties, socialization problems, inappropriate behaviors (e.g. disinhibition), sleep & feeding difficulties were the significant areas identified by the caregivers as a cause of major concern. Significantly high prevalence of ICD-10 psychiatric diagnosis in children with ID was found in Lahore, Pakistan. Support services for these children should be responsive not only to the needs of the child, but also to the needs of the family.

  10. Proton and electron deep dose profiles for retinoblastoma based on GEANT 4 code

    International Nuclear Information System (INIS)

    Braga, Flavia V.; Campos, Tarcisio P.R. de; Ribeiro, Kilder L.

    2009-01-01

    Herein, the dosimetry responses to a retinoblastoma proton and electron radiation therapy were investigated. The computational tool applied to this simulation was the Geant4 code, version 4.9.1. The code allows simulating the charge particle interaction with eyeball tissue. In the present simulation, a box of 4 cm side water filled had represented the human eye. The simulation was performed considering mono energetic beams of protons and electrons with spectra of 57 to 70 MeV for protons and 2 to 8 MeV for electrons. The simulation was guide by the advanced hadron therapy example distributed with the Geant4 code. The phantom was divided in voxels with 0.2 mm side. The energy deposited in each voxel was evaluated taken the direct beam at one face. The simulation results show the delivery energy and therefore the dose deposited in each voxel. The deep dose profiles to proton and electron were plotted. The well known Bragg peak was reproduced for protons. The maximum delivered dose defined the position at the proton stopped. However, to electrons, the absorbed energies were delivered along its path producing a more continuous distribution following the water depth, but also being stopped in the end of its path. (author)

  11. Proton and electron deep dose profiles for retinoblastoma based on GEANT 4 code

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Flavia V., E-mail: flaviafisica@gmail.co [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Campos, Tarcisio P.R. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Ribeiro, Kilder L., E-mail: kilderlr@gmail.co [Universidade Estadual de Feira de Santana (UEFS), BA (Brazil). Dept. de Fisica

    2009-07-01

    Herein, the dosimetry responses to a retinoblastoma proton and electron radiation therapy were investigated. The computational tool applied to this simulation was the Geant4 code, version 4.9.1. The code allows simulating the charge particle interaction with eyeball tissue. In the present simulation, a box of 4 cm side water filled had represented the human eye. The simulation was performed considering mono energetic beams of protons and electrons with spectra of 57 to 70 MeV for protons and 2 to 8 MeV for electrons. The simulation was guide by the advanced hadron therapy example distributed with the Geant4 code. The phantom was divided in voxels with 0.2 mm side. The energy deposited in each voxel was evaluated taken the direct beam at one face. The simulation results show the delivery energy and therefore the dose deposited in each voxel. The deep dose profiles to proton and electron were plotted. The well known Bragg peak was reproduced for protons. The maximum delivered dose defined the position at the proton stopped. However, to electrons, the absorbed energies were delivered along its path producing a more continuous distribution following the water depth, but also being stopped in the end of its path. (author)

  12. Dominant Suppression of β1 Integrin by Ectopic CD98-ICD Inhibits Hepatocellular Carcinoma Progression

    Directory of Open Access Journals (Sweden)

    Bo Wu

    2016-11-01

    Full Text Available Hepatocellular carcinoma (HCC is currently the third most common cause of cancer-related death in the Asia-Pacific region. Our previous work showed that knockdown of CD98 significantly inhibits malignant HCC cell phenotypes in vitro and in vivo. The level of CD98 in the membrane is tightly regulated to mediate complex processes associated with cell–cell communication and intracellular signaling. In addition, the intracellular domain of CD98 (CD98-ICD seems to be of vital importance for recycling CD98 to the membrane after it is endocytosed. The intracellular and transmembrane domains of CD98 associate with β-integrins (primarily β1 but also β3, and this association is essential for CD98 mediation of integrin-like signaling and complements dominant suppression of β1-integrin. We speculated that isolated CD98-ICD would similarly suppress β1-integrin activation and inhibit the malignant behaviors of cancer cells. In particular, the exact role of CD98-ICD has not been studied independently in HCC. In this study, we found that ectopic expression of CD98-ICD inhibited the malignant phenotypes of HCC cells, and the mechanism possibly involves β1-integrin suppression. Moreover, the expression levels of CD98, β1-integrin-A (the activated form of β1-integrin and Ki-67 were significantly increased in HCC tissues relative to those of normal liver tissues. Therefore, our preliminary study indicates that ectopic CD98-ICD has an inhibitory role in the malignant development of HCC, and shows that CD98-ICD acts as a dominant negative mutant of CD98 that attenuates β1-integrin activation. CD98-ICD may emerge as a promising candidate for antitumor treatment.

  13. Automated detection of pain from facial expressions: a rule-based approach using AAM

    Science.gov (United States)

    Chen, Zhanli; Ansari, Rashid; Wilkie, Diana J.

    2012-02-01

    In this paper, we examine the problem of using video analysis to assess pain, an important problem especially for critically ill, non-communicative patients, and people with dementia. We propose and evaluate an automated method to detect the presence of pain manifested in patient videos using a unique and large collection of cancer patient videos captured in patient homes. The method is based on detecting pain-related facial action units defined in the Facial Action Coding System (FACS) that is widely used for objective assessment in pain analysis. In our research, a person-specific Active Appearance Model (AAM) based on Project-Out Inverse Compositional Method is trained for each patient individually for the modeling purpose. A flexible representation of the shape model is used in a rule-based method that is better suited than the more commonly used classifier-based methods for application to the cancer patient videos in which pain-related facial actions occur infrequently and more subtly. The rule-based method relies on the feature points that provide facial action cues and is extracted from the shape vertices of AAM, which have a natural correspondence to face muscular movement. In this paper, we investigate the detection of a commonly used set of pain-related action units in both the upper and lower face. Our detection results show good agreement with the results obtained by three trained FACS coders who independently reviewed and scored the action units in the cancer patient videos.

  14. Utilization of Integrated Child Development Services (ICDS Scheme by child beneficiaries in Coastal Karnataka, India

    Directory of Open Access Journals (Sweden)

    Saranya Sivanesan

    2016-06-01

    Full Text Available Background: India’s main early childhood development intervention the ICDS Scheme has been sustained for 40 years and has been successful in some ways. However, nearly half of the children under six years are still under nourished. The program in reducing the proportion of undernourished children over the past decade has been modest and slower in India than what has been achieved in other countries with comparable socio-economic indicators. Aims & Objectives: 1. To study the utilization of services offered to children under ICDS, 2. To assess the perception about the services. Materials & Methods: A community based cross sectional study was done among mothers of 271 children in the age group three to six years registered in anganwadis. Results: Median duration of absenteeism to anganwadi was five months during the last six months enquired. About 95.9% of registered child beneficiaries utilized supplementary nutrition services and only 48.7% mothers of child beneficiaries were attending nutrition and health education sessions. Among mothers who were aware of growth monitoring, only 73.6% of their children’s weight was checked regularly.  About 60% of mothers were not happy with the quality of food served to their children in the anganwadi. Among children adherent to anganwadi, 72.5% children’s weight remained normal. Conclusion: Only 75% children were regularly attending. Median duration of adherence to anganwadi services was only 12 months and the most common reason for not adhering to the services is due to their simultaneous enrollment in other private nursery school.

  15. Code query by example

    Science.gov (United States)

    Vaucouleur, Sebastien

    2011-02-01

    We introduce code query by example for customisation of evolvable software products in general and of enterprise resource planning systems (ERPs) in particular. The concept is based on an initial empirical study on practices around ERP systems. We motivate our design choices based on those empirical results, and we show how the proposed solution helps with respect to the infamous upgrade problem: the conflict between the need for customisation and the need for upgrade of ERP systems. We further show how code query by example can be used as a form of lightweight static analysis, to detect automatically potential defects in large software products. Code query by example as a form of lightweight static analysis is particularly interesting in the context of ERP systems: it is often the case that programmers working in this field are not computer science specialists but more of domain experts. Hence, they require a simple language to express custom rules.

  16. Constructing rule-based models using the belief functions framework

    NARCIS (Netherlands)

    Almeida, R.J.; Denoeux, T.; Kaymak, U.; Greco, S.; Bouchon-Meunier, B.; Coletti, G.; Fedrizzi, M.; Matarazzo, B.; Yager, R.R.

    2012-01-01

    Abstract. We study a new approach to regression analysis. We propose a new rule-based regression model using the theoretical framework of belief functions. For this purpose we use the recently proposed Evidential c-means (ECM) to derive rule-based models solely from data. ECM allocates, for each

  17. A Fuzzy Rule-based Controller For Automotive Vehicle Guidance

    OpenAIRE

    Hessburg, Thomas; Tomizuka, Masayoshi

    1991-01-01

    A fuzzy rule-based controller is applied to lateral guidance of a vehicle for an automated highway system. The fuzzy rules, based on human drivers' experiences, are developed to track the center of a lane in the presence of external disturbances and over a range of vehicle operating conditions.

  18. Tourette and tic disorders in ICD-11: standing at the diagnostic crossroads

    Directory of Open Access Journals (Sweden)

    Douglas W. Woods

    2014-01-01

    Full Text Available This article reflects discussion by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. After reviewing the historical classification of tic disorders, this article discusses their placement in ICD-11. Existing problems with diagnostic labels and criteria, appropriate placement of the tic disorders category within the ICD-11 system, and pragmatic factors affecting classification are reviewed. The article ends with recommendations to (a maintain consistency with the DSM-5 diagnostic labels for tic disorders, (b add a minimum duration guideline for a provisional tic disorder diagnosis, (c remove the multiple motor tic guideline for the diagnosis of Tourette disorder, and (d co-parent the tic disorder diagnoses in the disorders of the nervous system and the mental and behavioral disorders categories, with secondary co-parenting in the obsessive-compulsive and related disorders and neurodevelopmental disorders sections.

  19. Examining the impact of introducing ICD-MM on observed trends in maternal mortality rates in the UK 2003-13.

    Science.gov (United States)

    Knight, Marian; Nair, Manisha; Brocklehurst, Peter; Kenyon, Sara; Neilson, James; Shakespeare, Judy; Tuffnell, Derek; Kurinczuk, Jennifer J

    2016-07-20

    The causes of maternal death are now classified internationally according to ICD-MM. One significant change with the introduction of ICD-MM in 2012 was the reclassification of maternal suicide from the indirect group to the direct group. This has led to concerns about the impact of this reclassification on calculated mortality rates. The aim of this analysis was to examine the trends in maternal deaths in the UK over the past 10 years, and to investigate the impact of reclassification using ICD-MM on the observed rates. Data about all maternal deaths between 2003-13 in the UK were included in this analysis. Data about maternal deaths occurring prior to 2009 were obtained from previously published reports. The deaths of women from 2009-13 during or after pregnancy were identified through the MBRRACE-UK Confidential Enquiry into Maternal Deaths. The underlying causes of maternal death were reclassified from a disease-based system to ICD-MM. Maternal mortality rates with 95 % confidence intervals were calculated using national data on the number of maternities as the denominator. Rate ratios with 95 % CI were calculated to compare the change in rates of maternal death as per ICD-MM relative to the old classification system. There was a decrease in the maternal death rate between 2003-05 and 2011-13 (rate ratio (RR) 0.65; 95 % CI 0.54-0.77 comparing 2003-5 with 2011-13; p = 0.005 for trend over time). The direct maternal death rate calculated using the old classification decreased with a RR of 0.47 (95 % CI 0.34-0.63) when comparing 2011-13 with 2003-05; p = 0.005 for trend over time. Reclassification using ICD-MM made little material difference to the observed trend in direct maternal death rates, RR = 0.51 (95 % CI 0.39-0.68) when comparing 2003-5 with 2011-13; p = 0.005 for trend over time. The impact of reclassifying maternal deaths according to ICD-MM in the UK was minimal. However, such reclassification raises awareness of maternal suicides

  20. Hospital competitive intensity and perioperative outcomes following lumbar spinal fusion.

    Science.gov (United States)

    Durand, Wesley M; Johnson, Joseph R; Li, Neill Y; Yang, JaeWon; Eltorai, Adam E M; DePasse, J Mason; Daniels, Alan H

    2018-04-01

    Interhospital competition has been shown to influence the adoption of surgical techniques and approaches, clinical patient outcomes, and health care resource use for select surgical procedures. However, little is known regarding these dynamics as they relate to spine surgery. This investigation sought to examine the relationship between interhospital competitive intensity and perioperative outcomes following lumbar spinal fusion. This study used the Nationwide Inpatient Sample dataset, years 2003, 2006, and 2009. Patients were included based on the presence of the International Classification of Disease, Ninth Edition, Clinical Modification (ICD-9-CM) codes corresponding to lumbar spinal fusion, as well as on the presence of data on the Herfindahl-Hirschman Index (HHI). The outcome measures are perioperative complications, defined using an ICD-9-CM coding algorithm. The HHI, a validated measure of competition within a market, was used to assess hospital market competitiveness. The HHI was calculated based on the hospital cachement area. Multiple regression was performed to adjust for confounding variables including patient age, gender, primary payer, severity of illness score, primary versus revision fusion, anterior versus posterior approach, national region, hospital bed size, location or teaching status, ownership, and year. Perioperative clinical outcomes were assessed based on ICD-9-CM codes with modifications. In total, 417,520 weighted patients (87,999 unweighted records) were analyzed. The mean cachement area HHI was 0.31 (range 0.099-0.724). The average patient age was 55.4 years (standard error=0.194), and the majority of patients were female (55.8%, n=232,727). The majority of procedures were primary spinal fusions (92.7%, n=386,998) and fusions with a posterior-only technique (81.5%, n=340,271). Most procedures occurred in the South (42.5%, n=177,509) or the Midwest (27.0%, n=112,758) regions. In the multiple regression analysis, increased hospital

  1. Modeling Guidelines for Code Generation in the Railway Signaling Context

    Science.gov (United States)

    Ferrari, Alessio; Bacherini, Stefano; Fantechi, Alessandro; Zingoni, Niccolo

    2009-01-01

    Modeling guidelines constitute one of the fundamental cornerstones for Model Based Development. Their relevance is essential when dealing with code generation in the safety-critical domain. This article presents the experience of a railway signaling systems manufacturer on this issue. Introduction of Model-Based Development (MBD) and code generation in the industrial safety-critical sector created a crucial paradigm shift in the development process of dependable systems. While traditional software development focuses on the code, with MBD practices the focus shifts to model abstractions. The change has fundamental implications for safety-critical systems, which still need to guarantee a high degree of confidence also at code level. Usage of the Simulink/Stateflow platform for modeling, which is a de facto standard in control software development, does not ensure by itself production of high-quality dependable code. This issue has been addressed by companies through the definition of modeling rules imposing restrictions on the usage of design tools components, in order to enable production of qualified code. The MAAB Control Algorithm Modeling Guidelines (MathWorks Automotive Advisory Board)[3] is a well established set of publicly available rules for modeling with Simulink/Stateflow. This set of recommendations has been developed by a group of OEMs and suppliers of the automotive sector with the objective of enforcing and easing the usage of the MathWorks tools within the automotive industry. The guidelines have been published in 2001 and afterwords revisited in 2007 in order to integrate some additional rules developed by the Japanese division of MAAB [5]. The scope of the current edition of the guidelines ranges from model maintainability and readability to code generation issues. The rules are conceived as a reference baseline and therefore they need to be tailored to comply with the characteristics of each industrial context. Customization of these

  2. Non-binary unitary error bases and quantum codes

    Energy Technology Data Exchange (ETDEWEB)

    Knill, E.

    1996-06-01

    Error operator bases for systems of any dimension are defined and natural generalizations of the bit-flip/ sign-change error basis for qubits are given. These bases allow generalizing the construction of quantum codes based on eigenspaces of Abelian groups. As a consequence, quantum codes can be constructed form linear codes over {ital Z}{sub {ital n}} for any {ital n}. The generalization of the punctured code construction leads to many codes which permit transversal (i.e. fault tolerant) implementations of certain operations compatible with the error basis.

  3. Combination Rules for Morse-Based van der Waals Force Fields.

    Science.gov (United States)

    Yang, Li; Sun, Lei; Deng, Wei-Qiao

    2018-02-15

    In traditional force fields (FFs), van der Waals interactions have been usually described by the Lennard-Jones potentials. Conventional combination rules for the parameters of van der Waals (VDW) cross-termed interactions were developed for the Lennard-Jones based FFs. Here, we report that the Morse potentials were a better function to describe VDW interactions calculated by highly precise quantum mechanics methods. A new set of combination rules was developed for Morse-based FFs, in which VDW interactions were described by Morse potentials. The new set of combination rules has been verified by comparing the second virial coefficients of 11 noble gas mixtures. For all of the mixed binaries considered in this work, the combination rules work very well and are superior to all three other existing sets of combination rules reported in the literature. We further used the Morse-based FF by using the combination rules to simulate the adsorption isotherms of CH 4 at 298 K in four covalent-organic frameworks (COFs). The overall agreement is great, which supports the further applications of this new set of combination rules in more realistic simulation systems.

  4. Concurrence of rule- and similarity-based mechanisms in artificial grammar learning.

    Science.gov (United States)

    Opitz, Bertram; Hofmann, Juliane

    2015-03-01

    A current theoretical debate regards whether rule-based or similarity-based learning prevails during artificial grammar learning (AGL). Although the majority of findings are consistent with a similarity-based account of AGL it has been argued that these results were obtained only after limited exposure to study exemplars, and performance on subsequent grammaticality judgment tests has often been barely above chance level. In three experiments the conditions were investigated under which rule- and similarity-based learning could be applied. Participants were exposed to exemplars of an artificial grammar under different (implicit and explicit) learning instructions. The analysis of receiver operating characteristics (ROC) during a final grammaticality judgment test revealed that explicit but not implicit learning led to rule knowledge. It also demonstrated that this knowledge base is built up gradually while similarity knowledge governed the initial state of learning. Together these results indicate that rule- and similarity-based mechanisms concur during AGL. Moreover, it could be speculated that two different rule processes might operate in parallel; bottom-up learning via gradual rule extraction and top-down learning via rule testing. Crucially, the latter is facilitated by performance feedback that encourages explicit hypothesis testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Cardiometabolic Risk Factors Among 1.3 Million Adults With Overweight or Obesity, but Not Diabetes, in 10 Geographically Diverse Regions of the United States, 2012–2013

    Science.gov (United States)

    Horberg, Michael; Koebnick, Corinna; Young, Deborah Rohm; Waitzfelder, Beth; Sherwood, Nancy E.; Daley, Matthew F.; Ferrara, Assiamira

    2017-01-01

    Introduction Various phenotypes of overweight and obesity pose various health risks. The objective of this study was to determine the prevalence of 4 commonly measured cardiometabolic risk factors (CRFs) among adults with overweight or obesity, but not diabetes, at the time of the study. Methods We analyzed data for 1,294,174 adults (aged ≥20 y) who were members of one of 4 integrated health systems. Each cohort member had a body mass index in 2012 or 2013 that indicated overweight or obesity. We determined the presence of 4 CRFs within 1 year of the first BMI measurement: elevated blood pressure (systolic ≥130 mm Hg or diastolic >85 mm Hg or ICD-9-CM [International Classification of Diseases, Ninth Revision, Clinical Modification] diagnosis code 401.0–405.9); elevated triglycerides (≥150 mg/dL or ICD-9-CM 272.1); low high-density lipoprotein cholesterol (obesity class and demographic characteristics with multivariable logistic regression. Results Among participants with overweight (52.5% of the sample), 18.6% had none of the 4 CRFs. Among the 47.5% of participants with obesity, 9.6% had none; among participants with morbid obesity, 5.8% had none. Age was strongly associated with CRFs in multivariable analysis. Conclusion Almost 10% of participants with obesity had no CRFs. Overweight or obesity increases cardiometabolic risk, but the number and type of CRFs varied substantially by age, even among participants with morbid obesity. PMID:28278130

  6. Integrated Child Development Services (ICDS): harbinger of safe motherhood and child development.

    Science.gov (United States)

    Lal, S

    1993-01-01

    . IEC has been expanding, but community participation has not kept pace. The strong community based infrastructure needs additional support particularly from the health sector. Program expansion into adolescent health and sex education was considered desirable. ICDs should be viewed as a development activity at the village level to astute women an integrated learning for life experience.

  7. Rules of thumb for minimising subsoil compaction

    DEFF Research Database (Denmark)

    Schjønning, Per; Lamandé, Mathieu; Keller, T

    2012-01-01

    was primarily determined by wheel load, but an effect of the other factors was also detected. Based on published recommendations for allowable stresses in the soil profile, we propose the ‘50-50 rule’: At water contents around field capacity, traffic on agricultural soil should not exert vertical stresses...... in excess of 50 kPa at depths >50 cm. Our combined data provide the basis for the ‘8-8 rule’: The depth of the 50-kPa stress isobar increases by 8 cm for each additional tonne increase in wheel load and by 8 cm for each doubling of the tyre inflation pressure. We suggest that farmers use this simple rule...

  8. Intellectual developmental disorders: towards a new name, definition and framework for "mental retardation/intellectual disability" in ICD-11.

    Science.gov (United States)

    Salvador-Carulla, Luis; Reed, Geoffrey M; Vaez-Azizi, Leila M; Cooper, Sally-Ann; Martinez-Leal, Rafael; Bertelli, Marco; Adnams, Colleen; Cooray, Sherva; Deb, Shoumitro; Akoury-Dirani, Leyla; Girimaji, Satish Chandra; Katz, Gregorio; Kwok, Henry; Luckasson, Ruth; Simeonsson, Rune; Walsh, Carolyn; Munir, Kemir; Saxena, Shekhar

    2011-10-01

    Although "intellectual disability" has widely replaced the term "mental retardation", the debate as to whether this entity should be conceptualized as a health condition or as a disability has intensified as the revision of the World Health Organization (WHO)'s International Classification of Diseases (ICD) advances. Defining intellectual disability as a health condition is central to retaining it in ICD, with significant implications for health policy and access to health services. This paper presents the consensus reached to date by the WHO ICD Working Group on the Classification of Intellectual Disabilities. Literature reviews were conducted and a mixed qualitative approach was followed in a series of meetings to produce consensus-based recommendations combining prior expert knowledge and available evidence. The Working Group proposes replacing mental retardation with intellectual developmental disorders, defined as "a group of developmental conditions characterized by significant impairment of cognitive functions, which are associated with limitations of learning, adaptive behaviour and skills". The Working Group further advises that intellectual developmental disorders be incorporated in the larger grouping (parent category) of neurodevelopmental disorders, that current subcategories based on clinical severity (i.e., mild, moderate, severe, profound) be continued, and that problem behaviours be removed from the core classification structure of intellectual developmental disorders and instead described as associated features.

  9. Epidemiology of fatal and nonfatal injuries in the Avianca plane crash: Avianca Flight 052, January 25, 1990. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Barancik, J.I.; Kramer, C.F.; Thode, H.C. Jr.; Kahn, C.J. [Brookhaven National Lab., Upton, NY (United States); Greensher, J.; Schechter, S. [Nassau County Dept. of Health, Mineola, NY (United States)

    1992-11-01

    On January 25, 1990 Avianca Flight 052 crashed without a conflagration after running out of fuel; 73 persons died, 85 survived. Epidemiological, biostatistical, and related analytical methods were used for the analysis of decedent and survivor injury patterns and for the purpose of examining selected EMS and hospital issues-relative to disaster planning and incident management and response. Medical examiner and hospital records for all decedents and survivors were identified, abstracted, and coded using the International Classification of Diseases with Clinical Modifications, 9th Edition (ICD 9-CM) to determine the nature of injuries and comorbid conditions. Injury severity values were determined using the 1985 Abbreviated Injury Scale with Epidemiologic Modifications (AIS 85-EM).

  10. Group representations, error bases and quantum codes

    Energy Technology Data Exchange (ETDEWEB)

    Knill, E

    1996-01-01

    This report continues the discussion of unitary error bases and quantum codes. Nice error bases are characterized in terms of the existence of certain characters in a group. A general construction for error bases which are non-abelian over the center is given. The method for obtaining codes due to Calderbank et al. is generalized and expressed purely in representation theoretic terms. The significance of the inertia subgroup both for constructing codes and obtaining the set of transversally implementable operations is demonstrated.

  11. Organizational Knowledge Transfer Using Ontologies and a Rule-Based System

    Science.gov (United States)

    Okabe, Masao; Yoshioka, Akiko; Kobayashi, Keido; Yamaguchi, Takahira

    In recent automated and integrated manufacturing, so-called intelligence skill is becoming more and more important and its efficient transfer to next-generation engineers is one of the urgent issues. In this paper, we propose a new approach without costly OJT (on-the-job training), that is, combinational usage of a domain ontology, a rule ontology and a rule-based system. Intelligence skill can be decomposed into pieces of simple engineering rules. A rule ontology consists of these engineering rules as primitives and the semantic relations among them. A domain ontology consists of technical terms in the engineering rules and the semantic relations among them. A rule ontology helps novices get the total picture of the intelligence skill and a domain ontology helps them understand the exact meanings of the engineering rules. A rule-based system helps domain experts externalize their tacit intelligence skill to ontologies and also helps novices internalize them. As a case study, we applied our proposal to some actual job at a remote control and maintenance office of hydroelectric power stations in Tokyo Electric Power Co., Inc. We also did an evaluation experiment for this case study and the result supports our proposal.

  12. PRINCIPLES- AND RULES-BASED ACCOUNTING DEBATE. IMPLICATIONS FOR AN EMERGENT COUNTRY

    Directory of Open Access Journals (Sweden)

    Deaconu Adela

    2011-07-01

    Full Text Available By a qualitative analysis, this research observes whether a principles-based system or a mixed version of it with the rules-based system, applied in Romania - an emergent country - is appropriate taking into account the mentalities, the traditions, and other cultural elements that were typical of a rules-based system. We support the statement that, even if certain contextual variables are common to other developed countries, their environments significantly differ. To be effective, financial reporting must reflect the firm's context in which it is functioning. The research has a deductive approach based on the analysis of the cultural factors and their influence in the last years. For Romania it is argue a lower accounting professionalism associated with a low level of ambiguity tolerance. For the stage analysed in this study (after the year 2005 the professional reasoning - a proxy for the accounting professional behaviour - took into consideration the fiscal and legal requirements rather than the accounting principles and judgments. The research suggest that the Romanian accounting practice and the professionals are not fully prepared for a principles-based system environment, associated with the ability to find undisclosed events, facing ambiguity, identifying inferred relationships and using intuition, respectively working with uncertainty. We therefore reach the conclusion that in Romania institutional amendments affecting the professional expertise would be needed. The accounting regulations must be chosen with great caution and they must answer and/ or be adjusted, even if the process would be delayed, to national values, behaviour of companies and individual expertise and beliefs. Secondly, the benefits of applying accounting reasoning in this country may be enhanced through a better understanding of their content and through practical exercise. Here regulatory bodies may intervene for organizing professional training programs and acting

  13. An investigation of care-based vs. rule-based morality in frontotemporal dementia, Alzheimer's disease, and healthy controls.

    Science.gov (United States)

    Carr, Andrew R; Paholpak, Pongsatorn; Daianu, Madelaine; Fong, Sylvia S; Mather, Michelle; Jimenez, Elvira E; Thompson, Paul; Mendez, Mario F

    2015-11-01

    Behavioral changes in dementia, especially behavioral variant frontotemporal dementia (bvFTD), may result in alterations in moral reasoning. Investigators have not clarified whether these alterations reflect differential impairment of care-based vs. rule-based moral behavior. This study investigated 18 bvFTD patients, 22 early onset Alzheimer's disease (eAD) patients, and 20 healthy age-matched controls on care-based and rule-based items from the Moral Behavioral Inventory and the Social Norms Questionnaire, neuropsychological measures, and magnetic resonance imaging (MRI) regions of interest. There were significant group differences with the bvFTD patients rating care-based morality transgressions less severely than the eAD group and rule-based moral behavioral transgressions more severely than controls. Across groups, higher care-based morality ratings correlated with phonemic fluency on neuropsychological tests, whereas higher rule-based morality ratings correlated with increased difficulty set-shifting and learning new rules to tasks. On neuroimaging, severe care-based reasoning correlated with cortical volume in right anterior temporal lobe, and rule-based reasoning correlated with decreased cortical volume in the right orbitofrontal cortex. Together, these findings suggest that frontotemporal disease decreases care-based morality and facilitates rule-based morality possibly from disturbed contextual abstraction and set-shifting. Future research can examine whether frontal lobe disorders and bvFTD result in a shift from empathic morality to the strong adherence to conventional rules. Published by Elsevier Ltd.

  14. Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke; Pedersen, Susanne; van den Broek, K.C.; Kraaier, Karin; Scholten, Marcoen; Van der Palen, Job

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  15. Gender Differences in Psychological Distress and Quality of Life in Patients with an ICD 1-Year Postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Pedersen, Susanne S.; van den Broek, Krista; Kraaier, Karin; Scholten, Marcoen; van der Palen, Jacobus Adrianus Maria

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  16. Approaching application of risk-based inspection to ASME code section XI

    International Nuclear Information System (INIS)

    Hedden, Owen F.

    1995-01-01

    This paper will describe current efforts within the ASME Boiler and Pressure Vessel Committee's Subcommittee on Nuclear Inservice Inspection to introduce risk-based technology to optimize inservice inspection of nuclear power plants. The subcommittee is responsible for the content of ASME Boiler and Pressure Vessel Code Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. The paper will first provide the historical background for the inspection program currently in Section XI. It will then describe the development of new technology through the ASME Center for Research and Technology Development program. Next, the work now going on in two of the groups under the Section XI committee will be described in detail. Each of these two efforts is directed toward the application of new risk-based inspection technology to nuclear piping systems. Finally, the directions of additional research and applications of the technology will be discussed. (author)

  17. Designing Fuzzy Rule Based Expert System for Cyber Security

    OpenAIRE

    Goztepe, Kerim

    2016-01-01

    The state of cyber security has begun to attract more attention and interest outside the community of computer security experts. Cyber security is not a single problem, but rather a group of highly different problems involving different sets of threats. Fuzzy Rule based system for cyber security is a system consists of a rule depository and a mechanism for accessing and running the rules. The depository is usually constructed with a collection of related rule sets. The aim of this study is to...

  18. State of art in FE-based fuel performance codes

    International Nuclear Information System (INIS)

    Kim, Hyo Chan; Yang, Yong Sik; Kim, Dae Ho; Bang, Je Geon; Kim, Sun Ki; Koo, Yang Hyun

    2013-01-01

    Fuel performance codes approximate this complex behavior using an axisymmetric, axially-stacked, one-dimensional radial representation to save computation cost. However, the need for improved modeling of PCMI and, particularly, the importance of multidimensional capability for accurate fuel performance simulation has been identified as safety margin decreases. Finite element (FE) method that is reliable and proven solution in mechanical field has been introduced into fuel performance codes for multidimensional analysis. The present state of the art in numerical simulation of FE-based fuel performance predominantly involves 2-D axisymmetric model and 3-D volumetric model. The FRAPCON and FRAPTRAN own 1.5-D and 2-D FE model to simulate PCMI and cladding ballooning. In 2-D simulation, the FALCON code, developed by EPRI, is a 2-D (R-Z and R-θ) fully thermal-mechanically coupled steady-state and transient FE-based fuel behavior code. The French codes TOUTATIS and ALCYONE which are 3-D, and typically used to investigate localized behavior. In 2008, the Idaho National Laboratory (INL) has been developing multidimensional (2-D and 3-D) nuclear fuel performance code called BISON. In this paper, the current state of FE-based fuel performance code and their models are presented. Based on investigation into the codes, requirements and direction of development for new FE-based fuel performance code can be discussed. Based on comparison of models in FE-based fuel performance code, status of art in the codes can be discussed. A new FE-based fuel performance code should include typical pellet and cladding models which all codes own. In particular, specified pellet and cladding model such as gaseous swelling and high burnup structure (HBS) model should be developed to improve accuracy of code as well as consider AC condition. To reduce computation cost, the approximated gap and the optimized contact model should be also developed

  19. ANALISIS FAKTOR-FAKTOR YANG MEMPENGARUHI INTELLECTUAL CAPITAL DISCLOSURE(ICD

    Directory of Open Access Journals (Sweden)

    Thresya Stephani

    2011-05-01

    Full Text Available Increased attention regarding intellectual capital as a dominant factor in the growingcompetitiveness and strength of a firm has encouraged the organizations to disclose theirintellectual capital. This study aims to analyze the factors that affect the disclosure of intellectualcapital, namely firm size, firm age, leverage, profitability, and type of auditor in a firm. Thesamples used were secondary data from the Indonesia Stock Exchange (IDX Annual Report ofmanufacturing companies listed on the Stock Exchange in 2008-2010. Samples were taken witha purposive sampling method, and who meet the criteria for sample selection. This study usesMultiple Linear Regression Analysis, with t statistics test the hypothesis testing and statistical testF. The results showed that firm size, leverage, and type of auditor affect the intellectual capitaldisclosure(ICD. However, firm age and profitability has no effect on ICD

  20. Knowledge base rule partitioning design for CLIPS

    Science.gov (United States)

    Mainardi, Joseph D.; Szatkowski, G. P.

    1990-01-01

    This describes a knowledge base (KB) partitioning approach to solve the problem of real-time performance using the CLIPS AI shell when containing large numbers of rules and facts. This work is funded under the joint USAF/NASA Advanced Launch System (ALS) Program as applied research in expert systems to perform vehicle checkout for real-time controller and diagnostic monitoring tasks. The Expert System advanced development project (ADP-2302) main objective is to provide robust systems responding to new data frames of 0.1 to 1.0 second intervals. The intelligent system control must be performed within the specified real-time window, in order to meet the demands of the given application. Partitioning the KB reduces the complexity of the inferencing Rete net at any given time. This reduced complexity improves performance but without undo impacts during load and unload cycles. The second objective is to produce highly reliable intelligent systems. This requires simple and automated approaches to the KB verification & validation task. Partitioning the KB reduces rule interaction complexity overall. Reduced interaction simplifies the V&V testing necessary by focusing attention only on individual areas of interest. Many systems require a robustness that involves a large number of rules, most of which are mutually exclusive under different phases or conditions. The ideal solution is to control the knowledge base by loading rules that directly apply for that condition, while stripping out all rules and facts that are not used during that cycle. The practical approach is to cluster rules and facts into associated 'blocks'. A simple approach has been designed to control the addition and deletion of 'blocks' of rules and facts, while allowing real-time operations to run freely. Timing tests for real-time performance for specific machines under R/T operating systems have not been completed but are planned as part of the analysis process to validate the design.