WorldWideScience

Sample records for rtof diffractometer facility

  1. Optimization of a neutron detector system for the fourier RTOF-diffractometer facility at the ETRR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Kady, A S.I.; El-Shaer, Y H [Reactor and Neutron physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    This work deals with optimization of a detector system for use with the fourier reverse time of flight (RTOF) diffractometer facility recently installed at the ETRR-1 reactor. The detector system of the diffractometer was designed for detecting neutrons scattered from the sample. It consists of 4 independent scintillation detector elements arranged according to the time focusing geometry in order to increase the luminosity of the diffractometer for the given resolution. Each of the detector elements is made of 1 mm thick {sup 6} Li-glass scintillator (NE-912) whose surface area is 200 mm{sup 2}. The present detector system ensures reliable identification and separation of thermal neutron pulses from fast neutrons and gamma- quanta. It was found from measurements with Fe sample that it is possible to make neutron diffraction measurement, within one hour using the present detector system and with resultion 0.5%. 6 FIGS.

  2. New development for the reverse time of flight analysis of spectra measured using Fourier Diffractometer Facilities

    CERN Document Server

    Maayouf, R M A

    2002-01-01

    The present work introduces a new design to replace the (Finnish make) reverse time of flight (RTOF) analyzer used for the Fourier diffractometer facilities. The new design applies a data acquisition system, a special interface card and software program installed in a PC computer, to perform the cross-correlation functions between signals received from the chopper-decoder and detector. It has been found from test measurements performed with the Cairo Fourier diffractometer facility (CFDF) and the similar high resolution one at JINR (Dubna-Russia) that the new design can successfully replace the Finnish make RTOF analyzer.

  3. Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Tiitta, A.T.

    1993-09-01

    The present work represents a further study of the basic RTOF Fourier multipurpose diffractometer, to start with, at the ET-RR-1 reactor. The functions of the suggested arrangement are thoroughly discussed and the possibilities if its expansion are also assessed. The flexibility of the arrangement allows its further expansion both for stress measurement at 90 deg. scattering angle with two detector banks at opposite sides of the incident beam and for operation in the transmission diffraction mode. (orig.). (19 refs., 10 figs., 1 tab.)

  4. Residual Stress Studies Using the Cairo Fourier Diffractometer Facility

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; El-Shaer, Y.H.

    2002-01-01

    The present paper deals with residual stress studies using the Cairo Fourier diffractometer facility CFDF. The CFDF is a reverse - time of -flight (RTOF) diffractometer; applies a Fourier chopper. The measurements were performed for copper samples in order to study the residual stress after welding. The maximum modulation of the Fourier chopper during the measurements was 136 khz; leading to a time resolution half-width of about 7 μ s. It has been found from the present measurements that, the resulting diffraction spectra could be successfully used for studying the residual stress; in the wavelength range between 0.7-2.9 A degree at ∼ 0.45 % relative resolution

  5. A New approach for the data acquisition system of the cairo fourier diffractometer

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Khalil, M.I.

    2000-01-01

    The present work deals with a new approach for the reverse time of flight (RTOF) analysis of the diffraction spectra. The approach is based on the same RTOF concept used for the design of a separate RTOF analyzer and applies, for data acquisition, a special interface card and software program installed in a PC computer, to perform the cross-correlation functions between the three signals received from the chopper decoder, detector and the pulsed neutron source respectively. The new approach have been realized for use with a Fourier diffractometer facility based on the RTOF concept. It has been found from test measurements performed with the high resolution Fourier diffractometer (HRFD) at the IBR-2 reactor (JINR, Dubna) that the new approach can successfully replace the RTOF analyzer

  6. Research studies performed using the Cairo Fourier Diffractometer Facility

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Ridikas, D.

    2009-12-01

    This report represents the results of the research studies performed using the Cairo Fourier Diffractometer Facility (CFDF), within 10 years after it was installed and put into operation at the beginning of 1996. The main components of the CFDF were supplied by the IAEA according to the technical assistance project EGY/1/022 'Upgrading of Research Reactor Utilization'. The present report is the second published INDC report, while the first one, published at the beginning of 1997, was about the performance of the CFDF and its main characteristic parameters. Plenty of measurements were performed since then, yielding several publications both in local and international scientific periodicals and resulting in 8 M.Sc. and Ph.D. degrees from Egyptian Universities. In addition, a new approach for the analysis of the neutron spectra was implemented using the CFDF. Specially designed interface card with proper software program was applied instead of the reverse time of flight (RTOF) and Finnish made analyzer originally attached to the facility. It has been verified that the new approach can successfully replace the RTOF analyzer, significantly decreasing the time of measurement and saving the reactor's operation time. Besides, a special fault diagnostic system program was developed and tested for caring and handling the possible failures of the CFDF. Moreover, measurements were carried out for the diffraction spectra emitted at different points of one of the samples. The latter was scanned across the neutron beam of the CFDF, for studying the stress after welding; used in industrial applications. (author)

  7. High-resolution diffractometer MINI-SFINKS

    International Nuclear Information System (INIS)

    Trunov, W.A.; Kudryaschev, W.A.; Uljanov, W.A.; Bulkin, A.P.; Muratov, W.G.; Korotkova, T.K.; Schebetov, A.F.

    1991-01-01

    The theoretical principles of the RTOF (reverse time-of-flight) method as well as the basic equations, the optimization of the neutron guides with Fourier chopper and the time-focussing detector setup are outlined. The powder diffractometer is described and some experimental results are given. The report was used as conceptual design basis for the FSS spectrometer at FRG-1 (GKSS Research Center) which has been optimized for non-destructive determination of residual stress. (orig.) With 18 figs., 3 tabs [de

  8. Analysis of antioxidants in insulation cladding of copper wire: a comparison of different mass spectrometric techniques (ESI-IT, MALDI-RTOF and RTOF-SIMS).

    Science.gov (United States)

    Schnöller, Johannes; Pittenauer, Ernst; Hutter, Herbert; Allmaier, Günter

    2009-12-01

    Commercial copper wire and its polymer insulation cladding was investigated for the presence of three synthetic antioxidants (ADK STAB AO412S, Irganox 1010 and Irganox MD 1024) by three different mass spectrometric techniques including electrospray ionization-ion trap-mass spectrometry (ESI-IT-MS), matrix-assisted laser desorption/ionization reflectron time-of-flight (TOF) mass spectrometry (MALDI-RTOF-MS) and reflectron TOF secondary ion mass spectrometry (RTOF-SIMS). The samples were analyzed either directly without any treatment (RTOF-SIMS) or after a simple liquid/liquid extraction step (ESI-IT-MS, MALDI-RTOF-MS and RTOF-SIMS). Direct analysis of the copper wire itself or of the insulation cladding by RTOF-SIMS allowed the detection of at least two of the three antioxidants but at rather low sensitivity as molecular radical cations and with fairly strong fragmentation (due to the highly energetic ion beam of the primary ion gun). ESI-IT- and MALDI-RTOF-MS-generated abundant protonated and/or cationized molecules (ammoniated or sodiated) from the liquid/liquid extract. Only ESI-IT-MS allowed simultaneous detection of all three analytes in the extract of insulation claddings. The latter two so-called 'soft' desorption/ionization techniques exhibited intense fragmentation only by applying low-energy collision-induced dissociation (CID) tandem MS on a multistage ion trap-instrument and high-energy CID on a tandem TOF-instrument (TOF/RTOF), respectively. Strong differences in the fragmentation behavior of the three analytes could be observed between the different CID spectra obtained from either the IT-instrument (collision energy in the very low eV range) or the TOF/RTOF-instrument (collision energy 20 keV), but both delivered important structural information. Copyright 2009 John Wiley & Sons, Ltd.

  9. Output fields from the NOAA Atlantic Real-Time Ocean Forecast System (RTOFS) for 2006-05-31 to 2017-03-21

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA Atlantic Real-Time Ocean Forecast System (RTOFS) dataset comprises output fields from the daily operational RTOFS model runs conducted at the National...

  10. User guide for the ECN stress-diffractometer facility

    International Nuclear Information System (INIS)

    Helmholdt, R.B.

    1994-01-01

    This report contains a description of the experimental set-up for residual stress measurements at beam hole HB4 of the High Flux Reactor at Petten. With this manual an experimentalist familiar with the properties of neutrons, diffraction techniques and the phenomenon (residual) stress will be able to operate the diffractometer, to check all the components on their proper operation and, if necessary, to repeat the alignment procedures. (orig.)

  11. Powder neutron diffractometers

    International Nuclear Information System (INIS)

    Adib, M.

    2002-01-01

    Basic properties and applications of powder neutron Diffractometers are described for optimum use of the continuous neutron beams. These instruments are equipped with position sensitive detectors, neutron guide tubes, and both high intensity and high resolution modes of operation are possible .The principles of both direct and Fourier reverse time-of-flight neutron Diffractometers are also given

  12. IBARAKI materials design diffractometer (iMATERIA)-Versatile neutron diffractometer at J-PARC

    International Nuclear Information System (INIS)

    Ishigaki, T.; Hoshikawa, A.; Yonemura, M.; Morishima, T.; Kamiyama, T.; Oishi, R.; Aizawa, K.; Sakuma, T.; Tomota, Y.; Arai, M.; Hayashi, M.; Ebata, K.; Takano, Y.; Komatsuzaki, K.; Asano, H.; Takano, Y.; Kasao, T.

    2009-01-01

    Ibaraki prefecture, the local government of the area for J-PARC site, was decided to build a versatile neutron diffractometer (IBARAKI Materials Design Diffractometer, iMATERIA) to promote an industrial application for neutron beam in J-PARC. iMATERIA is planned to be a high throughput diffractometer so that materials engineers and scientists can use it like the chemical analytical instruments in their materials development process. It covers in d range 0.18< d (A)<5 with Δd/d=0.16% at high resolution bank, and covers 5< d (A)<800 with gradually changing resolution at three detector bank (90 deg., low angle and small angle). Typical measuring time to obtain a 'Rietveld-quality' data is several minutes with the sample size of laboratory X-ray diffractometer. To promote industrial application, a utilization system for this diffractometer is required. We will establish a support system for both academic and industrial users who are willing to use neutron but have not been familiar with neutron diffraction. The analysis software is also very important for powder diffraction, we will also prepare a software package consisting of combination of several powder-diffraction software, structural databases and visualization. The construction of iMATERIA will be completed in the end of April 2008, as one of day-one instruments for J-PARC.

  13. Performance and main characteristic parameters of the Cairo fourier diffractometer facility at the ET-RR-1 reactor

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Abdel-Latif, I.; El-Kady, A.; El-Shafey, A.; Khalil, M.; El-Shaer, Y.

    1997-05-01

    This report represents the results of measurements performed recently with the Cairo Fourier diffractometer facility (CFDF). The main components of the CFDF were supplied by the IAEA according to the technical assistance project EGY/1/022. The CFDF performance is assessed and the main parameters are given. The neutron guide system attached to the CFDF provides a thermal neutron flux ∼ 10 6 n/cm 2 .sec at the sample position; free from fast neutrons and gamma rays background. It has been found, from measurements with different powder samples, that such value of the thermal neutron flux is adequate for neutron diffraction measurements, at scattering angle 2θ 90 deg. and D values between 0.7A and 2.5A; with 52% resolution. (author). 26 refs, 10 figs, 2 tabs

  14. IBARAKI Materials Design Diffractometer for J-PARC

    International Nuclear Information System (INIS)

    Ishigaki, Toru; Harjo, Stefanus; Yonemura, Masao; Kamiyama, Takashi; Aizawa, Kazuya; Oikawa, Kenichi; Sakuma, Takashi; Morii, Yukio; Arai, Masatoshi; Ebata, Kazuhiro; Takano, Yoshiki; Kasao, Takuro

    2006-01-01

    Ibaraki prefecture, the local government of the area for J-PARC site, has decided to build a versatile powder diffractometer (IBARAKI Materials Design Diffractometer) to promote industrial applications for neutron beams in J-PARC. This diffractometer is designed to be a high throughput one enabling materials scientists to use it like the chemical analytical instruments in their material development processes. It covers in d range 0.18< d(A)<5 with Δd/d=0.16% at the high-resolution scattering detector bank, and covers 5< d(A)<800 with gradually changing resolution. Typical measuring time to obtain a 'Rietveld-quality' data is several minutes for the sample size of laboratory X-ray diffractometer. To promote industrial application, a utilization system for this diffractometer is required. We will establish a support system for both academic and industrial users who are willing to use neutron but have not been familiar with neutron diffraction

  15. Development of engineering diffractometer at J-PARC

    International Nuclear Information System (INIS)

    Moriai, Atsushi; Torii, Shuki; Suzuki, Hiroshi; Harjo, Stefanus; Morii, Yukio; Arai, Masatoshi; Tomota, Yo; Suzuki, Tetsuya; Akiniwa, Yoshiaki; Kimura, Hidehiko; Akita, Koich

    2006-01-01

    An engineering diffractometer for investigations of stresses and crystallographic structures within engineering components is now being developed at J-PARC project. The diffractometer is designed to view a decoupled-poisoned liquid H 2 moderator providing neutrons with good symmetrical diffraction profiles in the acceptable wavelength range. The diffractometer will have a primary flight path of 40 m and a secondary flight path of 2.0 m for 90 o scattering detector banks, and will include a curved supermirror neutron guide to avoid intensity loss due to the long flight path and to reduce backgrounds from fast neutrons and gamma rays. Therefore, stresses with sufficient accuracies in many engineering studies are quite promising. The diffractometer involves a sample translator which is able to handle large and heavy real industrial-scaled components. Detailed design works are being continuously promoted. The optimization of the diffractometer has been performed with a Monte Carlo simulation, and an appropriate resolution of less than 0.2% in Δd/d has been confirmed

  16. Development of engineering diffractometer at J-PARC

    Energy Technology Data Exchange (ETDEWEB)

    Moriai, Atsushi [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan)]. E-mail: atsushi.moriai@jaea.go.jp; Torii, Shuki [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan); Suzuki, Hiroshi [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan); Harjo, Stefanus [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan); Morii, Yukio [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan); Arai, Masatoshi [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki, 319-1195 (Japan); Tomota, Yo [Ibaraki University, Hitachi-shi, Ibaraki, 316-8511 (Japan); Suzuki, Tetsuya [Ibaraki University, Hitachi-shi, Ibaraki, 316-8511 (Japan); Akiniwa, Yoshiaki [Nagoya University, Nagoya-shi, Aichi, 464-8603 (Japan); Kimura, Hidehiko [Nagoya University, Nagoya-shi, Aichi, 464-8603 (Japan); Akita, Koich [Musashi Institute of Technology, Setagaya-ku, Tokyo, 158-8557 (Japan)

    2006-11-15

    An engineering diffractometer for investigations of stresses and crystallographic structures within engineering components is now being developed at J-PARC project. The diffractometer is designed to view a decoupled-poisoned liquid H{sub 2} moderator providing neutrons with good symmetrical diffraction profiles in the acceptable wavelength range. The diffractometer will have a primary flight path of 40 m and a secondary flight path of 2.0 m for 90{sup o} scattering detector banks, and will include a curved supermirror neutron guide to avoid intensity loss due to the long flight path and to reduce backgrounds from fast neutrons and gamma rays. Therefore, stresses with sufficient accuracies in many engineering studies are quite promising. The diffractometer involves a sample translator which is able to handle large and heavy real industrial-scaled components. Detailed design works are being continuously promoted. The optimization of the diffractometer has been performed with a Monte Carlo simulation, and an appropriate resolution of less than 0.2% in {delta}d/d has been confirmed.

  17. Optimization of a neutron guide facility for the ET-RR-1 reactor. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Kady, A S [Reactor and Nutron Physics Department, Nuclear Research Center, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    This work deals with the optimization calculations carried out for a neutron guide facility at the ET-RR-1 reactor. The facility is intended for delivering slow neutrons, emitted from one of the ET-RR-1 reactor horizontal channels, to a Fourier RTOF diffractometer. Accordingly, wavelength-dependent neutron reflectivity calculations were carried out for Cu, Ge, natural Ni, and {sup 58} Ni; materials which are usually used as reflecting surfaces of the neutron guide mirror channel walls. The results of calculations were in favour of {sup 58} Ni as the best coating of the neutron guide mirror channel walls. {sup 58} Ni gives a characteristic wavelength {lambda}{sup *}=1.36 A degree of the neutron guide. This also leads to a value of the neutron flux, at the neutron guide output, 1.4 times more than that one resulting from coating the mirror channel walls with natural nickel. The optimized neutron guide, for effective luminosity value 2.4 x 10{sup 6}, was found to be 22 m in length with mirror channel walls coated with {sup 58} Ni. Such optimization of the neutron guide length, along which a curvature 3345 m in radius, leads to a strong suppression of the background of gamma quanta and fast neutrons. Besides, the neutron wavelength range, 1.O{Alpha} degree -4.O{Alpha} degree, produced by the optimized neutron guide facility allows for neutron diffraction measurements at D values between 0.71{Alpha} degree -2.33 {Alpha} degree. 5 figs., 1 tab.

  18. Study of the coma of comet 67P/Churyumov-Gerasimenko based on the ROSINA/RTOF instrument onboard Rosetta

    Science.gov (United States)

    Hoang, M.; Garnier, P.; Lasue, J.; Reme, H.; Altwegg, K.; Balsiger, H. R.; Bieler, A. M.; Calmonte, U.; Fiethe, B.; Galli, A.; Gasc, S.; Gombosi, T. I.; Jäckel, A.; Mall, U.; Le Roy, L.; Rubin, M.; Tzou, C. Y.; Waite, J. H., Jr.; Wurz, P.

    2015-12-01

    The ROSETTA spacecraft of ESA is in the environment of comet 67P/Churyumov-Gerasimenko since August 2014. Among the experiments onboard the spacecraft, the ROSINA experiment (Rosetta Orbiter Spectrometer for Ion and Neutral Analysis) includes two mass spectrometers (DFMS and RTOF) to analyze the composition of neutrals and ions, and a pressure sensor (COPS) to monitor the density and velocity of neutrals in the coma [1]. We will here analyze and discuss the data of the ROSINA/RTOF instrument during the comet escort phase. The Reflectron-type Time-Of-Flight (RTOF) mass spectrometer possesses a wide mass range and a high temporal resolution [1,2]. It was designed to measure cometary neutral gas as well as cometary ions. A detailed description of the main volatiles (H2O, CO2, CO) dynamics and of the heterogeneities of the coma will then be provided. The influence of various parameters on the coma measurements is investigated on a statistical basis, with the parameters being distance to the comet, heliocentric distance, longitude and latitude of nadir point. Our analysis of the northern hemisphere summer season shows the presence of water vapor mostly in the illuminated northern hemisphere near the neck region with cyclic diurnal variations whereas CO2 was confined to the cold southern hemisphere with a more spatially homogeneous composition, in agreement with previous observations of 67P [2] or Hartley 2 [3]. A comparison will also be provided with the COPS total density and DFMS abundance measurements. [1] Balsiger et al., "ROSINA - Rosetta Orbiter Spectrometer for Ion and Neutral Analysis", Space Sci. Rev., 2007. [2] Scherer et al., "A novel principle for an ion mirror design in time-of-flight mass spectrometry," Int. Jou. Mass Spectr., 2006. [3] Hässig et al., "Time variability and heterogeneity in the coma of 67P/Churyumov-Gerasimenko", Science, 2015. [4] A'Hearn et al., "EPOXI at comet Hartley 2", Science, 2011.

  19. Comparison of different tandem mass spectrometric techniques (ESI-IT, ESI- and IP-MALDI-QRTOF and vMALDI-TOF/RTOF) for the analysis of crocins and picrocrocin from the stigmas of Crocus sativus L.

    Science.gov (United States)

    Koulakiotis, Nikolaos Stavros; Pittenauer, Ernst; Halabalaki, Maria; Tsarbopoulos, Anthony; Allmaier, Günter

    2012-03-30

    The expensive spice saffron originating from the stigmas of Crocus sativus L. and also applied in traditional Chinese medicine (TCM) constitutes a complex mixture of glycoconjugates varying not only in the aglycon structure, but also in glycosylation pattern. Therefore, various tandem mass spectrometric techniques were evaluated for their usefulness in structural elucidation. Three selected constituents of the stigmas of Crocus sativus L., trans- and cis-crocin-4 as well as picrocrocin, were isolated and purified by HPLC and finally analyzed by ESI-MS (ion trap, QqRTOF), IP-MALDI-MS (QqRTOF) and vMALDI-MS (TOF/RTOF) in combination with tandem mass spectrometry in collision energy regimes ranging from a few eV (LE) to 20 keV (HE) collisions for the first time. These data aid in structurally elucidating minor, unknown glycoconjugates originating from this plant-derived spice. LE-CID of isomeric crocins on either an ion trap with ESI or a QqRTOF-instrument with ESI or IP-MALDI as desorption/ionization technique only yielded a limited number of structurally diagnostic sodiated product ions related to the carbohydrate moiety as well as to the intact aglycon in contrast to true HE-CID. The low MW constituent picrocrocin did not yield useful LE-CID spectra, but showed a high number of structurally diagnostic product ions by HE-CID utilizing a vMALDI TOF/RTOF-instrument. The highest number of structurally diagnostic product ions allowing also determination of the carbohydrate linkage of the gentiobiose-moiety of isomeric crocins ((0,4)A(2), (3,5)A(2) product ions indicating a 1→6 carbohydrate linkage) was only achievable by HE-CID. Fragmentation of the aglycon was not observed by any collision energy regime applied. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Time-of-flight neutron diffractometer for monocrystal study

    International Nuclear Information System (INIS)

    Anan'ev, B.N.; Balagurov, A.M.; Barabash, I.P.; Georgiu, Z.; Shibaev, V.D.

    1979-01-01

    The design of a neutron diffractometer is discussed. It is used for structural analysis of single crystals on the basis of time-of-flight measurements. The diffractometer is positioned along the axis of a beam of the IBR-30 pulse reactor, its average power is 29 kW. The mechanical part of the diffractometer consists of a massive foundation with a threeaxial goniometer, a rotatable platform with a collimator and a 3 He counter. The flowsheet of a control unit is given, which is used to position the rotatable platform of the diffractometer. The control unit includes a 14 digic binary counter for rotation angle recording, a parallel-to-series converter, a control signal shaper, two position shift registers, and a servo mechanism. The accuracy of diffraction maxima is evaluated. It is found that the ratio D(t)sup(1/2)/t (D(t) is a time dispersion of diffraction maxima, t is total time-of-flight time), which characterize the resolution of the diffractometer, is equal to 0.5% at the Bragg angle Q=45 deg and the neutron wavelength Λ=1 A

  1. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  2. Multiwire area x-ray diffractometers

    International Nuclear Information System (INIS)

    Hamlin, R.

    1985-01-01

    The multiwire proportional counter is at this writing the only type of two-dimensional position-sensitive X-ray detector capable of collecting diffraction data accurate enough for solution of new protein structures. The first diffractometer system to use this type of detector (the Mark I diffractometer system) was assembled at the University of California, San Diego and has collected the data used to solve for four new protein structures. Similar diffractometer systems using a single thin, flat multiwire counter are now being constructed in several other laboratories around the world, and several of these should routinely be collecting good diffraction data from protein and perhaps even virus crystals by 1986. A table describing some of these other systems is included later in this chapter. The next step in the evolution of area diffractometer systems based on the multiwire proportional counter is more complete coverage of the solid angle of the diffraction pattern - more complete than the 10 - 40% coverage possible with one flat multiwire counter. The phenomenon called ''parallax'' makes it impractical to intercept the whole diffraction pattern with one flat, xenon-filled multiwire counter. Two strategies for dealing with parallax are now being pursued. One strategy involves adding a spherical drift region to the front of a flat multiwire counter and a detector using this idea will be described. The other strategy, one being pursued by the author, involves building an array of flat detectors arranged to approximate a section of the surface of a sphere. The array of flat detectors gives more flexibility in crystal-to-detector distance and distributes the dead time over many detectors, thereby allowing the full array to have a high counting rate capacity even using only medium speed (2 μsec) position readout circuits for each individual detector

  3. The DSP-based RTOF-correlator for high resolution Fourier diffractometers

    Energy Technology Data Exchange (ETDEWEB)

    Butenko, V A; Drozdov, V A; Kirilov, A S [Frank Lab. of Neutron Physics of the Academy of Sciences of Slovakia, Bratislava (Slovakia)

    1996-12-31

    To improve efficiency of the time-of-flight analysis, the correlation and the Fourier methods are used with a preliminary neutron flux modulation. In this case the elastically scattered neutron spectrum is calculated as a function of the cross-correlation of the detector signal and the neutron flux modulation. 10 refs.; 5 figs.

  4. The development of a time of flight diffractometer, FIONA

    International Nuclear Information System (INIS)

    Goodyear, A.G.; Miller, R.J.R.

    1975-11-01

    A neutron diffractometer, FIONA, has been built at AWRE in order to study structure and equation of state data of materials at high pressures and elevated temperatures. It is required that the sample should be subjected to pressures up to 60 kbar and temperatures up to 800 0 K. There is a further requirement that the diffractometer should have a multi-detector system to make the maximum use of the neutrons available from the 5 MW HERALD reactor. Both these requirements can be met by using a time of flight diffractometer. The instrument is described. (author)

  5. Write-up for the diffractometer D1 at Risoe

    International Nuclear Information System (INIS)

    Bundgaard, J.; Krebs Larsen, F.; Lebech, B.; Nielsen, M.H.; Skaarup, P.

    1982-05-01

    Manual for the crystallographic program system used to control the 4-circle neutron diffractometer D1/TASII at DR3, Risoe. The mechanical part of the diffractometer consists of a monochromator part which allows an easy change of incident neutron wavelenght and a four-circle HUBER goniostate consisting of an Euler cradle (HUBER 512) and two horizontal goniometers (HUBER 440 and HUBER 430). The goniostate is computer controlled by a PDP-11/34 interfaced via CAMAC modules. The PDP-11/34 computer has a 128 k byte memory, two hard magnetic disc stations, a fast DEC-writer terminal and a screen terminal. The diffractometer can be operated remotely via modem and telephone line connections from remote stations such as the University of Aarhus and ILL, Grenoble. Minor parts of the software used to control the diffractometer were developed at Risoe while the major parts were a generous gift to Risoe from College 5, the diffraction group, at the Institute Laue-Langevin, Grenoble, France. (editors)

  6. Neutron spectrum measurements from a neutron guide tube facility at the ETRR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Sayed, L A.A.; El-Kady, A S.I. [Reactor and Neutron Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The present work deals with measurements of the neutron spectrum emitted from a neutron guide tube (NGT) recently installed at one of the ETRR-1 reactor horizontal channels designed to deliver thermal neutrons, free from fast neutrons and gamma ray background, to a fourier reverse-time-of-flight (RTOF) diffractometer. The measurements were performed using a {sup 6} Li glass scintillation detector combined with a multichannel analyzer set at channel width 4 M sec and installed at 3.4 m from a disc Fermi chopper. Also a theoretical model was specially developed for the neutron spectrum calculations. According to the model developed, the spectrum calculated was found to be in good agreement with the measured one. It was found, both from measurements and calculations, that the spectrum emitted from the NGT covers, after transmission through a fourier chopper, neutron wavelengths from 1-4 A adequate for neutron diffraction measurements at D values between 0.71-2.9 A respectively. 6 FIGS.

  7. Data acquisition system for linear position sensitive detector based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, A.; Prafulla, S.; Srivastava, V.D.; Mukhopadhyaya, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2003-03-01

    This data acquisition system is developed to serve the requirements of various linear 1PSD based neutron diffractometers. A neutron diffractometer uses a neutron beam as a probe to study the crystallographic properties of materials. Presently two multi-PSD and two single-PSD diffractometers are commissioned and a few more are being installed in Dhruva. This data acquisition system is installed at each of these - diffractometers. Different requirements of individual diffractometers were studied and reconciled to design a single data acquisition system, which can be easily configured or customized for individual setups. The charge division in a linear PSD is converted to a position output with the help of an RDC (Ratio ADC). The ftont-end electronics, which consist of preamplifiers and shaping amplifiers, provide an interface between a PSD and an RDC. A PC add-on card is designed around a Transputer. It can interface 16 RDCs, a few motor controls and on/off controls. Data acquisition and other controls are implemented in the Transputer program. A front-end Windows98 application merges the raw data of different RDCs to obtain the equiangular data. Through software the data acquisition system can be configured for diffetent diffractometers. Commercially available hardware is also integrated as,a part of the data acquisition system in some of the setups. The data acquisition system is working reliably as a part of two single PSD and two multi-PSD diffractometers. It can handle data rates upto 15 K/Sec without any loss of counts. It has played a significant role in providing improved throughput and utilization ofvarious diffractometers. The'data acquisition system and its different applications are presented in this report. (author)

  8. Resolution of the neutron diffractometer of the Mexican Nuclear Center

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Ita T, A. De

    2003-01-01

    The neutron diffractometer has three collimators and a monochromator of which it depends the resolution of the same one and exists a commitment between the resolution of the diffractometer and its intensity; if it is sought to work with more resolution, the intensity will diminish, and also, if one has little volume of the material, the diffracted light it is diminished, so the selection of the values of the collimators is this way important to have an unique value of the resolution of the diffractometer. (Author)

  9. Write-up for the Diffractometer D1 at Risø

    DEFF Research Database (Denmark)

    Bundgaard, Jørgen; Krebs Larsen, F.; Lebech, Bente

    Manual for the crystallographic program system used to control the 4-circle neutron diffractometer D1/TASII at DR3, Risø. The mechanical part of the diffractometer consists of a monochromator part which allows an easy change of incident neutron wavelength and a four-circle HUBER goniostate consis...

  10. A control and recording system for a neutron diffractometer

    International Nuclear Information System (INIS)

    Czech, Z.; Turek, L.; Wierzewski, K.

    1982-01-01

    A digital system for automatic control and data recording being a part of a neutron diffractometer designed for measurement of the angular distribution of monochromatic neutrons is described. The system is built using digital TTL integrated circuits. Particular attention is drawn to the interesting design of the optimized cross-matrix which selects the elements subjected to recording. The system successfully works with the neutron diffractometer at the EWA reactor. (author)

  11. The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Priesmeyer, H.G.; Kudryashev, V.A.

    1991-01-01

    The present situation of Fourier time-of-flight (TOF) spectrometry is discussed using the FSS spectrometer as example. The use of the Fourier reverse TOF spectrometry, as an efficient tool for studying condensed matter, at a 2 MW (WWR-S type) reactor is also assessed. The arrangement of the RTOF spectrometer, which could be successfully used at such type of reactor, is introduced. The suggested arrangement applies a neutron guide tube of 24 m length and allows for effective luminosity 2.4.10 6 at a flight path distance of 3.6 m. The number of neutrons scattered from a sample (5 cm 3 in volume) and incident on the detector system, as estimated for the suggested arrangement, is ∝1.6.10 3 n/sec. Such high counting rate allows to measure a diffraction spectrum within less than an hour. (orig.) With 12 figs [de

  12. A reverse time of flight analyzer facility at the ETRR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Shafey, A S; Khalil, M I [Reactor and Neutron Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The present work deals both with the theory and performance of a reverse-time-of-flight (RTOF) analyzer designed to analyze pulses emitted from a fourier chopper recently put into operation at the ETRR-1 reactor. The RTOF analyze was found to be adequate for use with pick up pulses from the fourier chopper which operates following a frequency window suitable for rotation rates from 0-9000 rpm; synchronically with neutron pulses from a {sup 6} Li glass detector set at time focusing geometry for scattering angle 20=90 degree. It was possible, with the present RTOF analyzer to obtain diffraction patterns at neutron wavelength range between 1 - 4 A within a resolution = 0.5%. 8 FIGS.

  13. Introduction of neutron research facilities in Indonesia Nuclear Agency

    International Nuclear Information System (INIS)

    Nishida, Masayuki; Muslih, M. Refai; Minakawa, Nobuaki

    2004-01-01

    In this report, some facilities for neutron diffraction installed in Indonesia nuclear Agency (BATAN) are introduced. Rough sketch of BATAN, and facility arrangement in the reactor hall and the guide hall are schematically shown. The four facilities (powder diffractometer, four-circle goniometer, three-axis goniometer and neutron radiography system) are installed in the reactor hall and the three (small angle neutron scattering (SANS), high resolution SANS and high resolution powder diffractometer) in the guide hall. Neutron wavelengths determined from four hk1 planes of standard Si powder by the BATAN's neutron diffraction facility are compared with those measured by the similar facility in Japan Atomic Energy Research Institute (JAERI). The neutron diffraction profile of W-fiber reinforced Cu composite is measured by the BATAN's facility. The experimental results show the strong 110 preferred orientation to the fiber direction. (author)

  14. X-ray diffractometer configurations for thin film analysis

    International Nuclear Information System (INIS)

    Haase, A.

    1996-01-01

    A presentation of various configurations of focusing Seemann-Bohlin diffractometer, parafocusing Bragg-Brentano diffractometer and parallel beam are demonstrated. Equipped with different thin film attachments a comparison to conventional measurements are given. The application of different detector types like scintillation, gas proportional, electroluminescence (LUX) and solid state are described. Typical instrument set-ups for reflectometry, grazing incidence diffraction, total reflection, high resolution X-ray diffraction are explained. Different elements like slits, soller slits, pinhole collimators, crystal monochromators, monofiber (FOX) and polycapillaries (multifiber lens, Kumakhov lens'), flat or curved multilayer with constant or variable d-spacing, and their combinations are presented. The comparison of different beam conditioners in peak-to-background ratios are given. Wavelength dispersive scans show the energy discrimination possibilities of different beam optics

  15. X-ray diffraction analysis with diffractometer DRON-1

    International Nuclear Information System (INIS)

    Bochenin, V.I.

    1978-01-01

    Rapid methods of phase quantitative analysis of wolframite (FeMn)WO 4 and molybdenite MoS 2 in industrial materials using DRON-1 diffractometer are suggested. Diffractometer with spectrometric attachment was used for determination of (FeMn)WO 4 in industrial raw materials. Results of the above analysis have been compared with the data of chemical analysis, their good agreement has been shown. Time of wolframite determination in one sample is 8-10 min. Method of standard background with respect to absorption properties of medium has been developed for MoS 2 rapid determination in enriched molybdenum ore. Time of molybdenite determination in one sample is 3-4min., error is 4 % rel. in MoS 2 concentration range from 15.4 to 36.7 %

  16. A nanoscale ordered materials diffractometer for the SNS

    International Nuclear Information System (INIS)

    Neuefeind, Joerg; Chipley, Kenneth K.; Tulk, Chris A.; Simonson, J. Michael; Winokur, Michael J.

    2006-01-01

    The Nanoscale Ordered Materials Diffractometer (NOMAD) is one of five neutron scattering instruments being managed within the Spallation Neutron Source (SNS) Instruments-Next Generation (SING) project. NOMAD is designed as a high-flux, medium-resolution diffractometer using a large bandwidth of neutron energies and extensive detector coverage to perform structural determinations of local order in crystalline and amorphous materials. The instrument will enable studies of a large variety of samples ranging from liquids, solutions, glasses, polymers, and nanocrystalline materials to long-range ordered crystals and will allow unprecedented access to high-resolution pair distribution functions, small-contrast isotope substitution experiments, small sample sizes, and parametric studies. Project completion for the instrument is anticipated in 2010 and a review of the design status will be given

  17. X-ray diffractometer configurations for thin film analysis

    Energy Technology Data Exchange (ETDEWEB)

    Haase, A [Rich. Seifert and Co., Analytical X-ray Systems, Ahrensburg (Germany)

    1996-09-01

    A presentation of various configurations of focusing Seemann-Bohlin diffractometer, parafocusing Bragg-Brentano diffractometer and parallel beam are demonstrated. Equipped with different thin film attachments a comparison to conventional measurements are given. The application of different detector types like scintillation, gas proportional, electroluminescence (LUX) and solid state are described. Typical instrument set-ups for reflectometry, grazing incidence diffraction, total reflection, high resolution X-ray diffraction are explained. Different elements like slits, soller slits, pinhole collimators, crystal monochromators, monofiber (FOX) and polycapillaries (multifiber lens, Kumakhov lens`), flat or curved multilayer with constant or variable d-spacing, and their combinations are presented. The comparison of different beam conditioners in peak-to-background ratios are given. Wavelength dispersive scans show the energy discrimination possibilities of different beam optics.

  18. Computer-controlled CAMAC system for the operation of a neutron diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Zwoll, K; Mueller, K D [Kernforschungsanlage Juelich G.m.b.H. (Germany, F.R.). Zentrallabor fuer Elektronik; Will, G [Bonn Univ. (Germany, F.R.). Mineralogisches Inst.

    1976-10-01

    The paper describes a computer-controlled four-circle diffractometer for the investigation of single crystals by neutron diffraction. The hardware is based on the internationally standardised CAMAC system. This makes the system described here independent of the type of computer used and also largely independent of the mechanical equipment used. The software is written in the interpretative language FOCAL which is easy to learn and ensures high flexibility in programming and thus also in the use of the diffractometer.

  19. Soft X-ray diffractometer for synchrotron radiation

    CERN Document Server

    Gau, T S; Liu, K Y; Chung, C H; Chen, C K; Lai, S C; Shu, C H; Huang, Y S; Chao, C H; Lee, Y R; Chen, C T; Chang, S L

    2001-01-01

    An ultra-high vacuum soft X-ray diffractometer has been constructed and commissioned at the Synchrotron Radiation Research Center (SRRC) to investigate materials structures in mesoscale. The diffractometer, housed in a UHV tank, consists of a 6-circle goniometer, together with the systems for beam-collimation, signal detection, vacuum, and control panels. The kappa-phi (cursive,open) Greek-psi goniostat is adopted for the sample orientation. Crystal samples can be rotated along a given reciprocal lattice vector by using psi scan. Two orthogonal axes, gamma (or 2 theta) and delta, are used to move the detector. The detector is a semiconductor pin diode, which can be used in UHV ambient. This 6-circle goniometer allows for sample scanning of a wide range in the momentum space. The motors used for goniometer rotation and slit selection are UHV compatible. The UHV tank is placed on an XYZ table capable of positioning the center of the goniometer onto the incident beam. Test experiments have been carried on the 1-...

  20. Instrumentation for PSD-based neutron diffractometers at Dhruva ...

    Indian Academy of Sciences (India)

    These include three diffractometers with multiple PSDs and four with single ... causes ionization in the gas, the charge is collected at both ends of the wire and .... terface required for data acquisition, control, presentation and system setup. The.

  1. Improvement of detector system of the two-axis neutron powder diffractometer

    International Nuclear Information System (INIS)

    Xue Yanjie; Guo Liping; Chen Dongfeng; Zhang Baisheng; Chen Na; Zhang Li; Sun Kai; Xiao Hongwen; Zhang Lingfei; Wang Hongli; Li Junhong; Wu Erdong; Yuan Xuezhong

    2005-01-01

    The detector system of the two-axis neutron powder diffractometer at the Heavy Water Research Reactor of China Institute of Atomic Energy was improved by increasing the number of detectors from one to four and by installing the third Soller collimators with horizontal divergence of 20'. The measurements of Fe powder diffraction patterns show that the counting rate of the diffractometer is increased by a factor of 2.3 and the resolution is also improved at the lower and mediate scattering angle region. (author)

  2. Design and implementation of low-Q diffractometers at spallation sources

    International Nuclear Information System (INIS)

    Seeger, P.A.; Hjelm, R.P.

    1993-01-01

    Low-Q diffractometers at spallation sources that use time of flight methods have been successfully implemented at several facilities, including the Los Alamos Neutron Scattering Center. The proposal to build new, more powerful, advanced spallation sources using advanced moderator concepts will provide luminosity greater than 20 times the brightest spallation source available today. These developments provide opportunity and challenge to expand the capabilities of present instruments with new designs. The authors review the use of time of flight for low-Q measurements and introduce new designs to extend the capabilities of present-day instruments. They introduce Monte Carlo methods to optimize design and simulate the performance of these instruments. The expected performance of the new instruments are compared to present day pulsed source- and reactor-based small-angle neutron scattering instruments. They review some of the new developments that will be needed to use the power of brighter sources effectively

  3. HiQ - A high-Q diffractometer for PDF measurements

    International Nuclear Information System (INIS)

    Brunelli, M.; Fischer, H.E.; Gaehler, R.; Chatterji, T.

    2011-01-01

    The local structure of many important functional materials is often different from the average structure, as revealed by diffraction, due to, e.g. doping, mixed site occupancy, or formation of time-dependent local distortions. To get information on both the average and the local structures one needs to perform a joint Rietveld and PDF (Pair Distribution Function) analysis of the total scattering, for which we need data to Q = 30 - 35 Angstroms with Δd/d ∼ 3*10 -3 . Here, we describe how the hot-source diffractometer D4 can be adapted to achieve this capability, and outline one possible design of a dedicated high-Q diffractometer at the ILL (Laue Langevin Institute), using the vacant inclined hot-neutron beam IH2. (authors)

  4. Development of BATAN’s texture diffractometer (current status)

    Energy Technology Data Exchange (ETDEWEB)

    Priyanto, T. H., E-mail: thardi@batan.go.id; Bharoto,; Mugirahardjo, H.; Muslih, R.; Ramadhani, A.; Sairun [Center for Nuclear Industrial Material Technology (PTBIN) National Nuclear Energy Agency (BATAN) Kawasan Puspiptek Serpong, Tangerang Selatan (Indonesia)

    2015-04-16

    Texture Diffractometer, called DN2, is one of neutron diffractometers in BATAN which is dedicated for texture measurement using neutron diffraction method. To obtain better performance of the DN2, a flight tube goniometer have been installed between the monochromator and sample position. By adjusting the flight tube goniometer, defocusing effect at direct beam and background effect could be reduced significantly. Some experiments have been carried out to characterize DN2 performance. The flight tube goniometer alignment and neutron wavelength calibration were characterized using silicon standard sample Si640d. Data refinement of diffraction pattern was analyzed using MAUD software and it is obtained reliability factor with background, R{sub wpb}, reduced significantly, from 42.53 % to 19.36 % after setting of flight tube goniometer. Reliability factor without background (R{sub wp}) was reduced from 27.41% to 21.36%. Calibrated of neutron wavelengh, λ = 1,2799 Angstrom is obtained.

  5. Axial spatial distribution focusing: improving MALDI-TOF/RTOF mass spectrometric performance for high-energy collision-induced dissociation of biomolecules.

    Science.gov (United States)

    Belgacem, O; Pittenauer, E; Openshaw, M E; Hart, P J; Bowdler, A; Allmaier, G

    2016-02-15

    For the last two decades, curved field reflectron technology has been used in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometers, assisting in the generation of post-source-decay (PSD) or collision-induced dissociation (CID) without decelerating precursor ions, producing true high-energy CID spectra. The result was the generation of product ion mass spectra with product ions typical of high-energy (10 keV and beyond) collision processes. The disadvantage of this approach was the lack of resolution in CID spectra resulting from the excess laser energy deposition used to generate those MS/MS spectra. The work presented in this study overcomes this limitation and includes comprehensive examples of high-energy and high-resolution CID MALDI-MS/MS spectra of biomolecules. The devices used in this study are TOF/RTOF instruments equipped with a high-vacuum MALDI ion source. High-resolution and high-energy CID spectra result from the use of axial spatial distribution focusing (ASDF) in combination with curved field reflectron technology. A CID spectrum of the P14 R1 peptide exhibits product ion resolution in excess of 10,000 (FWHM) but at the same time yields typical high-energy product ions such as w- and [y-2]-type ion series. High-energy CID spectra of lipids, exemplified by a glycerophospholipid and triglyceride, demonstrate C-C backbone fragmentation elucidating the presence of a hydroxyl group in addition to double-bond positioning. A complex high mannose carbohydrate (Man)8 (GlcNAc)2 was also studied at 20 keV collision energy and revealed further high-energy product ions with very high resolution, allowing unambiguous detection and characterization of cross-ring cleavage-related ions. This is the first comprehensive study using a MALDI-TOF/RTOF instrument equipped with a curved field reflectron and an ASDF device prior to the reflectron. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley

  6. Data acquisition and processing software for linear PSD based neutron diffractometers

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Ghodgaonkar, M.D.

    2003-01-01

    As a part of data acquisition system for various single and multi-PSD diffractometers software is developed to acquire the data and support the requirements of diffraction experiments. The software is a front-end Windows 98 application on PC and a transputer program on the MPSD card. The front-end application provides entire user interface required for data acquisition, control, presentation and system setup. Data is acquired and the diffraction spectra are generated in the transputer program. All the required hardware control is also implemented in the transputer program. The two programs communicate using a device driver named VTRANSPD. The software plays a vital role in customizing and integrating the data acquisition system for various diffractometer setups. Also the experiments are effectively automated in the software which has helped in making best use of available beam time. These and other features of the data acquisition and processing software are presented here. This software is being used along with the data acquisition system at a few single PSD and multi-PSD diffractometers. (author)

  7. New developments of TOF neutron diffraction at the IBR-2 pulsed reactor

    International Nuclear Information System (INIS)

    Balagurov, Anatoli M.

    2001-01-01

    Development of high-resolution RTOF Fourier technique for powder neutron diffraction studies is being continued at the IBR-2 pulsed reactor in Dubna. Besides some technical improvements in the operating HRFD instrument, a new dedicated instrument, Fourier Strain Diffractometer (FSD), for investigation of residual stresses in bulk materials has been constructed at IBR-2 in 1999. With a new HRFD Fourier chopper smaller than 10 μs TOF contribution in a resolution function was obtained in the experiment with perfect Si single crystal. A series of diffraction experiments with the beams from a new methane cold neutron moderator installed at the IBR-2 in 1999 is discussed. A comparison with the results obtained with the conventional water comb-like moderator shows that for various types of experiments, which are performed at HRFD and DN-2 diffractometers, the methane cold neutron source provides better conditions. (author)

  8. A computer-controlled CAMAC system for the operation of a neutron diffractometer

    International Nuclear Information System (INIS)

    Zwoll, K.; Mueller, K.D.; Will, G.

    1976-01-01

    The paper describes a computer-controlled four-circle diffractometer for the investigation of single crystals by neutron diffraction. The hardware is based on the internationally standardised CAMAC system. This makes the system described here independent of the type of computer used and also largely independent of the mechanical equipment used. The software is written in the interpretative language FOCAL which is easy to learn and ensures high flexibility in programming and thus also in the use of the diffractometer. (orig.) [de

  9. User guide for the POLARIS powder diffractometer at ISIS

    International Nuclear Information System (INIS)

    Hull, S.; Mayers, J.

    1989-11-01

    The POLARIS spectrometer at ISIS is currently being scheduled for use as a high intensity, medium resolution powder diffractometer. The particularly high neutron flux on POLARIS enables experiments to be performed with comparatively short counting times or on small sample volumes. This ability has been exploited during kinetic experiments of phase changes, where diffraction data is collected whilst the furnace is heating up. The provision of a large detector bank at 2 θ ∼ 90 0 is particularly important for studies of powder samples at high pressures. This scattering geometry has significant advantages for experiments of this kind, as suitable collimation of the incident and outgoing beams eliminates scattering from the surrounding pressure transmitting medium. This guide is intended to give a short description of the POLARIS powder diffractometer and to provide the basic information required to perform a powder diffraction experiment. (author)

  10. TOF powder diffractometer on a reactor source

    International Nuclear Information System (INIS)

    Bleif, H.J.; Wechsler, D.; Mezei, F.

    1999-01-01

    Complete text of publication follows. The performance of time-of-flight (TOF) methods on Long Pulse Spallation Sources can be studied at a reactor source. For this purpose a prototype TOF monochromator instrument will be installed at the KFKI reactor in Budapest. The initial setup will be a powder diffractometer with a resolution of δd/d down to 2 x 10 -3 at a wavelength of 1 A. The instrument uses choppers to produce neutron pulses of down to 10 μs FWHM. The optimal neutron source for a chopper instrument is a Long Pulse Spallation Source, but even on a continuous source simulations have shown that this instrument outperforms a conventional crystal monochromator powder diffractometer at high resolution. The main components of the TOF instrument are one double chopper defining the time resolution and two single choppers to select the wavelength range and to prevent frame overlap. For inelastic experiments a further chopper can be added in front of the sample. The neutron guide has a super-mirror coating and a curvature of 3500m. The total flight path is 20m and there are 24 single detectors in backscattering geometry. (author)

  11. A high resolution powder diffractometer using focusing optics

    Indian Academy of Sciences (India)

    E-mail: siruguri@csr.ernet.in. Abstract. In this paper, we describe the design, construction and performance of a new high resolution neutron powder diffractometer that has been installed at the Dhruva reactor, Trombay, India. The instrument employs novel design concepts like the use of bent, perfect crystal monochromator ...

  12. Angle calculations for a z-axis/(2S+2D) hybrid diffractometer

    DEFF Research Database (Denmark)

    Bunk, Oliver; Nielsen, Martin Meedom

    2004-01-01

    calculations are presented for a new 'hybrid' diffractometer consisting of a base instrument that can be combined with two different detector arms. With one of the detector arms, the instrument is a standard z-axis diffractometer as commonly used in surface studies. The other detector arm is designed...... for a heavy two-dimensional detector. The calculations are formulated in a general framework making it easy to incorporate, e. g. a second sample rotation stage, whereby it is possible to perform reflectivity and standard surface-crystallography measurements in the same geometry....

  13. An X-ray diffractometer specimen holder for use with reactive and toxic materials

    International Nuclear Information System (INIS)

    Huyton, A.; Munden, A.B.

    1979-04-01

    An X-ray diffractometer specimen holder has been designed for analysis of reactive sodium compounds which will satisfactorily seal the sample from the atmosphere. The holder can be readily filled in a glove-box and is easily transported for mounting on a vertical Philips PW 1051 X-ray diffractometer. It is considered that this holder could also be applied to a wide range of other reactive and toxic materials, e.g. plutonium or its compounds. (author)

  14. The IPEN/CNEN-SP PSD neutron diffractometer

    International Nuclear Information System (INIS)

    Parente, Carlos Benedicto Ramos; Mazzocchi, Vera Lucia; Mascarenhas, Yvonne Primerano

    2004-01-01

    Full text: A new IPEN-CNEN/SP neutron powder diffractometer is under construction at the 4 MW thermal IEA-R1m research reactor. It is an upgrading of the old IPEN-CNEN/SP multipurpose neutron diffractometer. The main modifications introduced in the old instrument are: installation of a position sensitive detector (PSD) and a bent perfect single crystal monochromator (a focusing Si monochromator). The PSD is formed by eleven linear detector elements, clamped together at each end to form a rigid plane. The PSD is installed in a detector shielding which is supported by two arms fixed in a large rotary table. This table provides the instrument with the 2θ angular movement. A smaller rotary table, placed underneath and concentric with the larger one, provides the ω(θ) movement. Both tables are driven by a computer controlled geared mechanism. The computer also makes the data acquisition. A rotating-oscillating collimator, placed at the entrance to the detector shielding, eliminates parasitic scattering from furnace or cryorefrigerator heat shields in the vicinity of the sample. The collimator also makes the PSD less sensitive to ambient background. The PSD spans an angular range of 20 deg of a diffraction pattern, resulting in a quite good resolution for the instrument. An extended powder diffraction pattern can be obtained by moving the detector and collecting the data in 20 deg segments. With a take-off angle of 84 deg, the monochromator can be positioned to produce 4 different wavelengths, namely 1.111, 1.399, 1.667 and 2.191 A. Other parts constructed for the new instrument are: a in-pile collimator, a monochromatic beam collimator and a neutron shield, large enough to accommodate the monochromator, a beam shutter and the monochromatic beam collimator. In comparison to the former instrument, the new diffractometer will have better resolution and will be ca. 600 times faster in data acquisition. At the present time, the new instrument is in the final steps of

  15. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  16. Instrumentation for PSD based neutron diffractometers at Dhruva reactor

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Prafulla, S.; Srivastava, V.D.; Behare, A.; Mukhopadhyay, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2004-01-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers, shaping amplifiers, ratio ADCs (RDC). The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here. (author)

  17. Data acquisition system for linear PSD based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, Anita; Ghodgaonkar, M.D.

    2001-01-01

    Single or multi-PSD configurations are used in different neutron diffractometer setups. A data acquisition system is developed to serve the gross requirements of all the diffractometer setups. It is also customized to specific requirements of different setups. The hardware is developed as a Transputer based add-on card. Most of the hardware functionality is handled in the Transputer program thus improving throughput of the system. The card can handle 16 RDCs, a few motor controls and on/off controls. The software comprises of a front-end Windows98 application, a Transputer program and a device driver. The data acquisition system performs data acquisition, analysis, display and storage. Analysis includes converting raw data of linear PSD to equiangular format, merging and clubbing the data to make a continuous equiangular spectrum. Calibration of individual PSD is a crucial activity in correctly merging the data coming from PSDs. (author)

  18. D1A, a high resolution neutron powder diffractometer with a bank of mylar collimators

    International Nuclear Information System (INIS)

    Hewat, A.W.; Bailey, I.

    1976-01-01

    This paper describes a first attempt at following the design criteria set out earlier for a high resolution conventional powder diffractometer. An existing machine, D1A, has been modified using a bank of ten high pressure 3 He counters and almost perfect 10minutes of arc mylar foil collimators. The system is more successful than earlier multicollimator arrangements because each of the collimator/counters is virtually identical; this permits automatic addition of the intensities so that a single high resolution profile, up to X40 times as intense as on the original diffractometer, is obtained just as easily as on a single counter machine. A comparison is made with the other powder diffractometers, D1B and D2 at the ILL. (Auth.)

  19. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

    Science.gov (United States)

    Pande, S. S.; Borkar, S. P.; Prafulla, S.; Srivastava, V. D.; Behare, A.; Mukhopadhyay, P. K.; Ghodgaonkar, M. D.; Kataria, S. K.

    2004-08-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2], shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

  20. Structural integrity assessment based on the HFR Petten neutron beam facilities

    CERN Document Server

    Ohms, C; Idsert, P V D

    2002-01-01

    Neutrons are becoming recognized as a valuable tool for structural-integrity assessment of industrial components and advanced materials development. Microstructure, texture and residual stress analyses are commonly performed by neutron diffraction and a joint CEN/ISO Pre-Standard for residual stress analysis is under development. Furthermore neutrons provide for defects analyses, i.e. precipitations, voids, pores and cracks, through small-angle neutron scattering (SANS) or radiography. At the High Flux Reactor, 12 beam tubes have been installed for the extraction of thermal neutrons for such applications. Two of them are equipped with neutron diffractometers for residual stress and structure determination and have been extensively used in the past. Several other facilities are currently being reactivated and upgraded. These include the SANS and radiography facilities as well as a powder diffractometer. This paper summarizes the main characteristics and current status of these facilities as well as recently in...

  1. High-speed single-crystal television diffractometer (software)

    International Nuclear Information System (INIS)

    Thomas, D.J.

    1982-01-01

    Area-detector diffractometers make possible almost ideal diffraction experiments. Until recently the performance of such instruments has been limited in practice by the available software. This general account discusses an unconventional way of indexing a lattice which is more appropriate for the calculations needed with normal-beam rotation geometry, and asserts the need to perform a continuous 'real-time' adaptive refinement to monitor the condition of the crystal and the detector. (orig.)

  2. Instrumentation of a manually programmed neutron diffractometer

    DEFF Research Database (Denmark)

    Hansen, K.B.; Neisig, K.E.

    1966-01-01

    This paper describes essentially the digital part of the instrumentation for a neutron diffractometer in which the measuring procedure is governed by a control unit involving a fixed number of program points. A simultaneously running test program monitors the information transfer from the data...... sources and to the print-out in table form. The experimental conditions must be set by a panel switch selected program, which allows a desired parameter program to be executed....

  3. New diffractometers at ILL Grenoble - the millennium program

    International Nuclear Information System (INIS)

    Hewat, A. W.

    2000-01-01

    Full text: New techniques for constructing detectors and monochromators are being used to build a number of new diffractometers at ILL Grenoble to provide an order of magnitude gain in efficiency, and higher resolution. Similar techniques might be applied at the new Australian reactor to provide world-class neutron instruments. These projects include a high resolution multi-detector powder diffractometer super-D2B, a modular microstrip detector for liquids and amorphous materials D4c, an array of 2D microstrip detectors for large molecular structures and fibre diffraction D19, a large high flux microstrip detector D20, a neutron image plate camera for structural and magnetic transitions T-LADI, and a dedicated neutron strain-scanner built with a large grant from the UK EPSRC. The super-D2B project will consist of 128 linear wire detectors behind an array of very fine Soeller collimators, which will provide a horizontal resolution of 5x10 -4 in d-spacing. Vertical resolution by charge division along the 300mm detector length will be used to correct for the curvature of the diffraction cones, greatly increasing the useful vertical acceptance angle. Prototype collimators and detectors have already been constructed. The new D4c detector is being installed in June 2000 on the liquids and amorphous materials diffractometer D4. It consists of a bank of 9 individual microstrip detectors covering a total of 160 degrees, with each detector containing 64 microstrip 'wires'. The complete diffraction pattern will be obtained with 2 positions of this detector bank, which is very efficient for short wavelength neutrons, and highly stable, as needed to measure small differences between amorphous materials using for example isotope contrast. The world's first microstrip powder diffractometer D20 is currently being re-built, and will be available again in October 2000. It consists of 1600 microstrip 'wires' in a single 160-degree chamber. The machine is so fast that it can follow

  4. Instrumentation for Position Sensitive Detector-Powder diffractometer at CENM-Maamora

    International Nuclear Information System (INIS)

    Messous, M.-Y.; Belhorma, B.; Labrim, H.; El-Bakkari, B.; Jabri, H.

    2013-06-01

    Linear position sensitive detectors are widely used to configure neutron diffractometer and other instruments. Necessary front-end electronics and data acquisition system was developed to fulfil such instruments built around the research reactor. In this paper, the front-end electronics dedicated to the neutron powder diffractometer which will be installed in the axial beam port of the Triga Mark II research reactor (Center of Nuclear Studies of Maamora) is described. It consists of High voltage power supply, a Position-decoder and a Multichannel analyzer and data acquisition software. The 3 He-PSD detector response exposed to the neutron flow emitted by 252 Cf source held in paraffin spheres with distinct thicknesses for moderation effect, is shown. Monte-Carlo N Particles code (MCNP) simulations were also performed to study both the detector performance and the paraffin efficiency. (authors)

  5. Automation of angular movement of the arm neutron diffractometer

    International Nuclear Information System (INIS)

    Aguilar H, F.; Herrera A, E.; Quintana C, G.; Torres R, C. E.; Reyes V, M.

    2015-09-01

    A technique to determine the crystal structure of some materials is the neutron diffraction. This technique consists on placing the material in question in a monoenergetic neutron beam obtained by neutron diffraction in a monochromator crystal. The neutron energy depends of the diffraction angle. The Instituto Nacional de Investigaciones Nucleares has a neutron diffractometer and monochromator crystals of pyrolytic graphite. This crystal can be selecting the neutron energy depending on the angle of diffraction in the glass. The radiation source for the neutron diffractometer is the TRIGA Mark III reactor of the Nuclear Center Dr. Nabor Carrillo Flores. During their operation are also obtained besides neutrons, β and γ radiation. The interest is to have thermal neutrons, so fast neutrons and γ rays are removed using appropriate shielding. The average neutron fluxes of the radial port RE2 of neutron diffractometer at power 1 MW are: heat flow 2,466 x 10 8 n cm -2 sec -1 and fast flow 1,239 x 10 8 n cm -2 sec -1 . The neutron detector is housed in a shield mounted on a mechanical linkage with which the diffraction angle is selected, and therefore the energy of the neutrons. The movement of this joint was performed by the equipment operator manually, so that accuracy to select the diffraction angle was not good and the process rather slow. Therefore a mechanical system was designed, automated by means of a motor as an actuator, a system of force transmission and an electronic control in order that the operator will schedule the diffraction angles and allow the count in the neutrons detection system in a simple manner. (Author)

  6. Control program of the neutron four-circle-diffractometer P32 at the SILOE reactor/CEN Grenoble

    International Nuclear Information System (INIS)

    Guth, H.; Paulus, H.; Reimers, W.; Heger, G.

    1983-09-01

    The four-circle diffractometer P32 for elastic neutron scattering on single crystals was installed at the SILOE reactor/CEN Grenoble in 1981. The control program, presented here, is a new update of the former program versions used at the FR2 reactor/Kernforschungszentrum Karlsruhe. Important improvements concerning reliability and handling of the diffractometer are added. (orig.) [de

  7. Control program of the neutron four-circle-diffractometer P110 at the ORPHEE reactor/CEN Saclay

    International Nuclear Information System (INIS)

    Guth, H.; Paulus, H.; Reimers, W.; Heger, G.

    1984-05-01

    The four-circle diffractometer P110 for elastic neutron scattering on single crystals was installed at the ORPHEE reactor/CEN Saclay in 1982. The control progam, presented here, is a new update of the former program versions used at the FR2 reactor. Important improvements concerning reliability and handling of the diffractometer are added. (orig./HP) [de

  8. A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Kamal, I., E-mail: imtiaz-kamal26@yahoo.com; Yunus, S. M., E-mail: yunussm11@yahoo.com; Datta, T. K., E-mail: tk-datta4@yahoo.com; Zakaria, A. K. M.; Das, A. K.; Aktar, S.; Hossain, S. [Institute of Nuclear Science and Technology, Atomic Energy Research Establishment, Ganakbari, Savar, Dhaka (Bangladesh); Berliner, R., E-mail: RB@instrumentationAssociates.com [Instrumentation Associates, Durham, North Carolina (United States); Yelon, W. B., E-mail: yelonwb@hotmail.com [Oak Ridge National Laboratory, Oak Ridge, Tennessee (United States)

    2016-07-12

    A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology

  9. Tricks and tips on handling a powder diffractometers

    Energy Technology Data Exchange (ETDEWEB)

    Veroli, C [CNR, Montelibretti, Rome (Italy). Istituto Chimica dei Materiali

    1996-09-01

    In the present work, the authors illustrate the procedure to be followed when small quantities of powder have to be analysed, and they also report how to generally reduce the measurement background. In addition, they describe how the diffractometer can be used to collect thin-film spectra. The experimental procedure requires careful handling because inappropriate or careless use of the instrument can lead to its damage.

  10. Optimization of flat and horizontally curved neutron monochromators for given diffractometer geometries

    International Nuclear Information System (INIS)

    Graf, H.A.

    1983-08-01

    The computer program MONREF was written for calculating the integrated intensity and the k-vector distribution produced by mosaic-crystal monochromators in neutron diffractometers of given geometries. The program treats flat and horizontally curved monochromators in Bragg reflection. Its basic algorithm is derived from Zachariasen's coupled differential equations which were modified to include the case of asymmetrically cut crystals. The calculations are restricted to the scattering in the experimental plane. In the first part of the report the program and its applications are described. In the second part a compilation of intensities is presented, calculated for crystals of Cu, Si, Ge and pyrolytic graphite commonly used as monochromators, in a standard diffractometer configuration. (orig.)

  11. Powder neutron diffractometers HRPT and DMCG

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, P; Doenni, A; Staub, U; Zolliker, M [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    Basic properties and applications of SINQ powder neutron diffractometers are described. For optimum use of the continuous neutron beams these instruments are equipped with position sensitive detectors, and both high-intensity and high-resolution modes of operation are possible. HRPT attaining resolutions {delta}d/d{<=}10{sup -3}, d=lattice spacing, at a thermal neutron channel of the target station and DMCG at a cold neutron guide coated with m=2 supermirrors, are complementary concerning the applications: the former will be mainly used for structural studies and the latter to investigate magnetic ordering phenomena. (author) figs., tabs., refs.

  12. The high resolution powder diffractometer (HRPD) at ISIS - a user guide

    International Nuclear Information System (INIS)

    Ibberson, R.M.; David, W.I.F.; Knight, K.S.

    1992-05-01

    This guide is intended to give a short description of the High Resolution Powder Diffractometer, HRPD, at ISIS and to provide the basic information required in order to perform a routine powder diffraction experiment. (Author)

  13. JAX: a micro-computer based X-ray diffractometer controller

    International Nuclear Information System (INIS)

    Naval, P.C. Jr.

    1987-05-01

    This paper describes a micro-computer based X-ray diffractometer controller and explores its possibilities in simplifying acquisition and analysis of X-ray powder diffraction data. The interrupt-driven controller can operate in both present time and present count data acquisition modes and allows a data analysis program to execute concurrently with data collection. (Auth.). 16 figs.; 2 tabs

  14. Mechanical design of a high-resolution x-ray powder diffractometer at the Advanced Photon Source.

    Energy Technology Data Exchange (ETDEWEB)

    Shu, D.; Lee, P.; Preissner, C.; Ramanathan, M.; Beno, M.; VonDreele, R.; Ranay, R.; Ribaud, L.; Kurtz, C.; Jiao, X.; Kline, D.; Jemian, P.; Toby, B.

    2007-01-01

    A novel high-resolution x-ray powder diffractometer has been designed and commissioned at the bending magnet beamline 11-BM at the Advanced Photon Source (APS), Argonne National Laboratory (ANL). This state-of-the-art instrument is designed to meet challenging mechanical and optical specifications for producing high-quality powder diffraction data with high throughput. The 2600 mm (H) X 2100 mm (L) X 1700 mm (W) diffractometer consists of five subassemblies: a customized two-circle goniometer with a 3-D adjustable supporting base; a twelve-channel high-resolution crystal analyzer system with an array of precision x-ray slits; a manipulator system for a twelve scintillator x-ray detectors; a 4-D sample manipulator with cryo-cooling capability; and a robot-based sample exchange automation system. The mechanical design of the diffractometer as well as the test results of its positioning performance are presented in this paper.

  15. Mechanical design of a high-resolution x-ray powder diffractometer at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu, D.; Lee, P.; Preissner, C.; Ramanathan, M.; Beno, M.; VonDreele, R.; Ranay, R.; Ribaud, L.; Kurtz, C.; Jiao, X.; Kline, D.; Jemian, P.; Toby, B.

    2007-01-01

    A novel high-resolution x-ray powder diffractometer has been designed and commissioned at the bending magnet beamline 11-BM at the Advanced Photon Source (APS), Argonne National Laboratory (ANL). This state-of-the-art instrument is designed to meet challenging mechanical and optical specifications for producing high-quality powder diffraction data with high throughput. The 2600 mm (H) X 2100 mm (L) X 1700 mm (W) diffractometer consists of five subassemblies: a customized two-circle goniometer with a 3-D adjustable supporting base; a twelve-channel high-resolution crystal analyzer system with an array of precision x-ray slits; a manipulator system for a twelve scintillator x-ray detectors; a 4-D sample manipulator with cryo-cooling capability; and a robot-based sample exchange automation system. The mechanical design of the diffractometer as well as the test results of its positioning performance are presented in this paper.

  16. Simple methods of aligning four-circle diffractometers with crystal reflections

    Energy Technology Data Exchange (ETDEWEB)

    Mitsui, Y [Tokyo Univ. (Japan). Faculty of Pharmaceutical Sciences

    1979-08-01

    Simple methods of aligning four-circle diffractometers with crystal reflections are devised. They provide the methods to check (1) perpendicularity of chi plane to the incident beam, (2) zero point of 2theta and linearity of focus-chi center-receiving aperture and (3) zero point of chi.

  17. D2B, a new high resolution neutron powder diffractometer at ILL Grenoble

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1987-01-01

    Applications of high resolution neutron powder diffraction to materials science have grown rapidly in the past 10 years, with the development of Rietveld methods of profile refinement, and new high resolution diffractometers and multidetectors. Materials studied range from catalysts to zeolites, and from battery electrodes to prestressed superconducting wires. Although the techniques have now been adapted for X-ray and synchrotron radiation, neutron powder diffraction retains unique advantages. In this paper we describe the design and first test measurements on the latest high resolution powder diffractometer D2B at ILL Grenoble. A review of the applications is published in Chemica Scripta (1986). (author) 9 refs., 6 figs., 2 tabs

  18. Automation of an X-ray diffractometer using a manually preset control system

    International Nuclear Information System (INIS)

    Berry, T.; Prentice, P.C.

    1978-11-01

    The measurements of lattice parameters of beta silicon carbide nuclear reactor temperature monitors at Dounreay were formerly carried out using an X-ray diffractometer connected to a simple step scan control system with an analysis time of 8 hours per specimen. A system is described whereby the step scan throughout of the X-ray diffractometer is increased by using an automatic sample charger and additional control electronics, allowing round-the-clock analysis. The original system which used Harwell 2000 series electronic units has been expanded to include an AERE designed goniometer control unit, a Philips sample changer with control unit, and a Honeywell chart recorder. The integrated circuit logic used, interconnections of modules, and operating instructions are given in appendices. (UK)

  19. A comparison between Engin and Engin-X, a new diffractometer optimized for stress measurement

    International Nuclear Information System (INIS)

    Dann, J.A.; Daymond, M.R.; Edwards, L.; James, J.A.; Santisteban, J.R.

    2004-01-01

    Engineering diffractometers are used extensively by both engineers and materials scientists for the measurement of strain within polycrystalline materials, both metallic and ceramic. In the past neutron diffractometers have generally been built as 'all-purpose' instruments, with designs that are compromises, balancing competing requirements to measure the intensities, positions and widths of diffraction peaks simultaneously. In contrast the newly constructed diffractometer ENGIN-X was designed with the single aim of making engineering strain measurements; essentially the accurate measurement of polycrystalline lattice parameters, at a precisely determined position. Under this design philosophy, considerable performance improvements have been obtained compared to the existing instrument. This paper details the design philosophy of this instrument, including tuneable incident resolution, together with the approaches used to realise the performance required. The improved instrument performance is demonstrated here, with results obtained during the commissioning of ENGIN-X. These results include strain mapping experiments, and demonstrate the influence of resolution on required count times, and provide a direct comparison with measurements from the existing ENGIN instrument at ISIS

  20. Resolution of the neutron diffractometer of the Mexican Nuclear Center; Resolucion del difractometro de neutrones del Centro Nuclear de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Garcia C, R.M. [Administracion Central de Laboratorio y Servicios Cientificos, Legaria 608, Col. Irrigacion, 11500 Mexico D.F. (Mexico); Ita T, A. De [UAM-A, San Pablo 180, Col. Reynosa Tamaulipas, 02200 Mexico D.F. (Mexico)

    2003-07-01

    The neutron diffractometer has three collimators and a monochromator of which it depends the resolution of the same one and exists a commitment between the resolution of the diffractometer and its intensity; if it is sought to work with more resolution, the intensity will diminish, and also, if one has little volume of the material, the diffracted light it is diminished, so the selection of the values of the collimators is this way important to have an unique value of the resolution of the diffractometer. (Author)

  1. Control of an X-ray diffractometer

    International Nuclear Information System (INIS)

    Bleif, H.J.; Degenhardt, K.H.; Herdam, G.

    1980-09-01

    As to the four-axis diffractometer control the following problems have beeen solved by using CAMAC-instrumentation: 1) Orientation of the crystal and adjustment of the limit switch are possible by manual operation. 2) The temperature of the crystal is adjusted and controlled by a process computer. 3) The computer controls the measuring sequence as follows: a) the crystal and the detector are put in the calculated position; b) measuring of the intensity with the measuring time being determined by a monitor counter (impulse pre-selection) or by a timer (time pre-selection); c) analog output of intensity; d) storing of the data on a data file. (orig./HP)

  2. Portable X-ray diffractometer equipped with XRF for archaeometry

    Science.gov (United States)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-09-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of "Tamonten holding a stupa" from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green.

  3. Portable X-ray diffractometer equipped with XRF for archaeometry

    International Nuclear Information System (INIS)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of 'Tamonten holding a stupa' from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green

  4. Slit and phase grating diffraction with a double crystal diffractometer

    International Nuclear Information System (INIS)

    Treimer, Wolfgang; Hilger, Andre; Strobl, Markus

    2006-01-01

    The lateral coherence properties of a neutron beam (λ=0.5248nm) in a double crystal diffractometer (DCD) were studied by means of single slit diffraction and by diffraction by different perfect Silicon phase gratings. Perfect agreements were found for the lateral coherence length measured with the slit and for the one determined by Silicon phase gratings, however, some peculiarities are still present

  5. Neutron Diffractometer; Neutronski difraktometar

    Energy Technology Data Exchange (ETDEWEB)

    Zivadinovic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    RA nuclear reactor is considered as a relatively strong neutron source producing the thermal neutron flux of about 3x10{sup 13} n/cm{sup 2} sec when operating at nominal power of 6.5 MW. Neutron diffraction method is applied in the field of solid state physics, material science, crystallography, magnetism, nuclear physic. Neutron diffractometer at the RA reactor consists of: system for obtaining collimated neutron beam from the horizontal experimental channel neutron monochromator; goniometer and electronic equipment for measurements and collecting the the measurement data. Nuklearni reaktor RA koji pri radu na snazi od 6,5 MW ima fluks termalnih neutrona oko 3x10{sup 13} n/cm{sup 2} sec predstavlja relativno jak izvor neutrona. Tehnika difrakcije neutrona primenjuje se u istrazivanjima fizike crvstog stanja, strukture materijala, kristalografije, magnetizma, nuklearne fizike. Neutronski difraktometar na reaktoru RA sastoji se od sistema za dobijanje kolimisanog snopa neutrona kroz horizontalni kanal reaktora; neutroskog monohromatora; goniometra i elektronskih uredjaja za merenja i registrovanje rezultata. Ovaj izvestaj sadrzi detaljan opis i seme neutronskog difraktometra sa pratecom opremom i elektronskim komponentama.

  6. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  7. A new beauty for 'ADONE': a high resolution powder diffractometer for synchrotron radiation experiments

    International Nuclear Information System (INIS)

    Burattini, E.; Simeoni, S.

    1991-01-01

    A high resolution powder diffractometer, connected to the wiggler magnet line BX1, is now operative at the Adone storage ring in Frascati. A Si channel-cut monochromator on the line allows operation in the range 1-3 A. To achieve the desired high resolution in the diffraction spectra, a 'triple-axis configuration' has been chosen: a vertical standing goniometer supports a flat Ge(111) crystal analyzer on the 2O arm. With this configuration, a value of less than 0.02 o for the FWHM of the diffraction peaks has been reached. The special design solutions adopted for a Seifer MZ VI goniometer and the microstep technology used in the stepper motor actuation assure a mechanical resolution better than 0.001 o . A special supporting table, with six degrees of freedom, has been made for the diffractometer orientation in front of the X-ray beam. An IBM-PC is dedicated to the diffractometer positioning control and preliminary data collection. As a Macintosh IICX provides for the data processing, a special software package, named 'Mac Dust', has been developed and is continuously updated. The first experimental results collected on-line during the instrument check-up are presented. (author) 5 figs., 1 tab., 11 refs

  8. IPNS time-of-flight single crystal diffractometer

    International Nuclear Information System (INIS)

    Schultz, A.J.; Teller, R.G.; Williams, J.M.

    1983-01-01

    The single crystal diffractometer (SCD) at the Argonne Intense Pulsed Neutron Source (IPNS) utilizes the time-of-flight (TOF) Laue technique to provide a three-dimensional sampling of reciprocal space during each pulse. The instrument contains a unique neutron position-sensitive 6 Li-glass scintillation detector with an active area of 30 x 30 cm. The three-dimensional nature of the data is very useful for fast, efficient measurement of Bragg intensities and for the studies of superlattice and diffuse scattering. The instrument was designed to achieve a resolution of 2% or better (R = δQ/Q) with 2 THETA > 60 0 and lambda > 0.7A

  9. Brookhaven Reactor Experiment Control Facility, a distributed function computer network

    International Nuclear Information System (INIS)

    Dimmler, D.G.; Greenlaw, N.; Kelley, M.A.; Potter, D.W.; Rankowitz, S.; Stubblefield, F.W.

    1975-11-01

    A computer network for real-time data acquisition, monitoring and control of a series of experiments at the Brookhaven High Flux Beam Reactor has been developed and has been set into routine operation. This reactor experiment control facility presently services nine neutron spectrometers and one x-ray diffractometer. Several additional experiment connections are in progress. The architecture of the facility is based on a distributed function network concept. A statement of implementation and results is presented

  10. Initial results from the high resolution powder diffractometer HRPD at ISIS

    International Nuclear Information System (INIS)

    David, W.I.F.; Harrison, W.T.A.; Johnson, M.W.

    1986-07-01

    The paper reviews the initial commissioning of the high resolution time-of-flight neutron powder diffractometer, HRPD, on the Spallation Neutron Source, ISIS, at the Rutherford Appleton Laboratory. Preliminary results have confirmed both intensity and resolution predictions indicating that (Δd/d) lies between 0.04% and 0.08% for all d-spacings between 0.2 and 5A. The scientific potential of this increased resolution over existing time-of-flight diffractometers has been demonstrated in the successful ab initio structure determination of an unknown inorganic material, FeAsO 4 , and the detailed study of subtle symmetry changes in NiO. The true instrumental resolution, however, has been observed in only a small number of experiments: sample broadening is often seen to play a dominant role in the determination of the peak shape, particularly at longer d-spacings. This leads to additional useful information about macroscopic properties, such as anisotropic crystallite size, strain distribution and sample homogeneity, but also results in a significant increase in complexity of peak-shape description and data-analysis strategy. (author)

  11. High-efficiency transmision neutron polarizer for high-resolution double crystal diffractometer

    International Nuclear Information System (INIS)

    Ioffe, A.; Krist, T.; Mezei, F.; Gordeev, G.; Ibrayev, B.

    1997-01-01

    An efficient transmission geometry neutron polarizer for the high-resolution double crystal diffractometer at HMI (λ=4.8 A) is described. A polarization of about 94% was achieved and the polarized neutron beam intensity amounts to 40% of the nonpolarized beam intensity. This opens up wide possibilities for the study of magnetic small-angle scattering for extremely small momentum transfer (Q∝10 -5 A -1 ). (orig.)

  12. Enhancement of TOF diffractometer Sirius with 90 detector bank

    CERN Document Server

    Oikawa, K; Torii, S; Mochiku, T

    2002-01-01

    A TOF powder diffractometer, Sirius, installed at the Neutron Science Laboratory (KENS) of the High Energy Accelerator Research Organization (KEK), has realized both high resolution and high intensity with its large backward detector bank together with supermirror guide. Sirius also has a large 90 detector bank (0.54 str), which is used for diffraction studies under special environments, such as high pressure, high temperature, and so on. Recent works using a high-pressure cell (Paris-Edinburgh cell) and a high-temperature furnace with a gas-control device (modeled on the Miller Furnace at IPNS) are presented. (orig.)

  13. Analysis of a drum chopper for use on a new small angle diffractometer at IPNS

    International Nuclear Information System (INIS)

    Crawford, R.K.; Epperson, J.E.; Thiyagarajan, P.; Carpenter, J.M.

    1990-01-01

    Light-weight drum choppers rotating at 15 Hz have been in use on the IPNS powder diffractometers for several years, where they serve to eliminate the delayed-neutron background from much of the spectral region of interest. Monte Carlo simulations indicate that a similar chopper operated at 15 Hz should do an excellent job of delayed-neutron removal in the new small-angle diffractometer being designed at IPNS. The simulations also show that when the same chopper is operated at 7.5 Hz it performs quite successfully as a frame-elimination chopper, effectively eliminating neutrons from alternate pulses and allowing extension of the useful wavelength range of the instrument to ∼28 Angstrom. Thus the incorporation of such a chopper should add considerably to the range and flexibility of the new instrument. 7 refs., 9 figs

  14. The new fourier diffractometer at the IBR-2 reactor: design and first results

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Balagurov, A.M.; Simkin, V.G.

    1992-01-01

    A high-resolution neutron powder Fourier diffractometer has been constructed at the pulsed reactor IBR-2 in Dubna. Preliminary results have confirmed resolution predictions indicating that Δd/d can be as small as 5x10 -4 over a wide d range with a good data accumulation rate. 3 refs.; 10 figs.; 1 tab

  15. Data transmission from the DRON-2 X-ray diffractometers to a computer

    International Nuclear Information System (INIS)

    Abramov, V.G.; Monov, N.A.; Sazonov, V.F.; Chernomorskaya, E.A.

    1991-01-01

    The circuit of data transmission from DRON-2 X-ray diffractometer to a measurement-computation complex based on UVK SM-3 computer and CAMAC crate is described. The data is transmitted along two-wire TRP 1x2 telephone line of 'current loop type'. Pulses from intensity channel outlet are transmitted as unipolar mark pulses of ∼1 μs duration. The channels are separated by amplitudes

  16. Structural study of hydrogen and hydration by the IBARAKI biological crystal diffractometer (iBIX)/industrial use

    International Nuclear Information System (INIS)

    Tanaka, Ichiro; Hosoya, Takaaki; Kusaka, Katsuhiro; Niimura, Nobuo; Yamada, Taro; Tomoyori, Katsuaki; Yokoyama, Takeshi; Ohhara, Takashi; Kurihara, Kazuo; Ohnishi, Yuki; Yoshimura, Masashi; Kawamura, Takahiro; Oosumi, Takashi; Uchida, Hirohisa; Suzuki, Eiichiro; Kashiwagi, Tatsuki; Miyamoto, Akio; Furukawa, Yasunori

    2011-01-01

    IBARAKI Biological Crystal Diffractometer (iBIX), a new neutron diffractometer for protein crystallography, was constructed as a next generation neutron source in J-PARC (Japan Proton Accelerator Research Complex) and it has begun operation since December 2008. During a fiscal year of 2009, 14 detector units, the basic part of data reduction software and an equipment of cryostream cooler to 20K became available, and measurements and structural analysis of an organic standard crystal were succeeded. Since 120kW accelerator operation in December 2009, neutron measurements for structural analysis of several crystals of inorganic, organic compounds and proteins including industrial users' have been carried out and some of these data sets have been analyzed to the degree that positions of the hydrogen and the hydrated water could be identified. (author)

  17. ASTACUS, a time focussing neutron diffractometer based on the reverse Fourier principle

    International Nuclear Information System (INIS)

    Tiitta, A.; Hiismaeki, P.

    1979-01-01

    Design principles, technical realization, and performance of a new time-of-flight neutron diffractometer, built for high resolution powder work and successfully operated for one year, are reported. The range of lattice spacings covered by the instrument extends from 0.3 down to 0.04 nm while the resolution varies from about 0.16% up to 0.8% respectively as dicated by the 10 μs time resolution and about 8 m flight path. (Auth.)

  18. GLAD: The IPNS (Intense Pulsed Neutron Source) Glass, Liquid, and Amorphous materials Diffractometer

    International Nuclear Information System (INIS)

    Crawford, R.K.; Price, D.L.; Haumann, J.R.; Kleb, R.; Montague, D.G.; Carpenter, J.M.; Susman, S.; Dejus, R.J.

    1989-01-01

    A number of years of experience in diffraction from amorphous materials has now been accumulated at various pulsed neutron sources. Workshops t IPNS and elsewhere have distilled some of this experience to provide a set of criteria for a new diffractometer dedicated to an optimized for structural studies of amorphous materials. This paper discusses the instrument GLAD (Glass, Liquid, and Amorphous Materials Diffractometer) which has been designed to meet these criteria and is now being built at IPNS. This instrument involves the use of relatively short-wavelength neutrons and a sophisticated neutron detection and acquisition system. A preliminary, simplified version of the instrument has been constructed while the final version is still under design, in order to develop the data acquisition and analysis techniques and to develop methods for collection of data with adequate quality (low background) at short wavelengths. This paper will briefly outline the final instrument envisioned and its calculated performance, but will focus mostly on the details of the detection/acquisition system and the calibration and data collection procedures which have been developed. The brief operating experience which has been gained to data with the preliminary instrument version will also be summarized. 6 refs., 12 figs

  19. A new high resolution neutron powder diffractometer at the Brookhaven high flux beam reactor

    International Nuclear Information System (INIS)

    Passell, L.; Bar-Ziv, S.; Gardner, D.W.; Cox, D.E.; Axe, J.D.

    1991-01-01

    A high resolution neutron powder diffractometer under construction at the Brookhaven HFBR is expected to be completed by mid-1991. The new machine will have a Ge (511) monochromator with a take-off angle of 120 o (λ=1.89A) and 64 3 He counters in the detector bank. There will be interchangeable collimators before the monochromator allowing a choice of 5 or 11' horizontal divergence, and 10 cm-high, 5' collimators in front of the detectors. In the higher resolution mode, Δd/d is expected to be about 6x10 -4 at the resolution minimum. The diffractometer is generally similar to D2B at the Institut Laue-Langevin except for the monochromator. This will consist of a vertically focussing array of segments 3x1.27 cm in dimensions cut from stacks of 20 0.43 mm wafers that have been pressed and brazed together. Preliminary measurements indicate that a mosaic width of 0.1-0.15 o and a peak reflectivity of 25% can be achieved in this way. (author) 2 figs., 22 refs

  20. A time-focusing Fourier chopper time-of-flight diffractometer for large scattering angles

    International Nuclear Information System (INIS)

    Heinonen, R.; Hiismaeki, P.; Piirto, A.; Poeyry, H.; Tiitta, A.

    1975-01-01

    A high-resolution time-of-flight diffractometer utilizing time focusing principles in conjunction with a Fourier chopper is under construction at Otaniemi. The design is an improved version of a test facility which has been used for single-crystal and powder diffraction studies with promising results. A polychromatic neutron beam from a radial beam tube of the FiR 1 reactor, collimated to dia. 70 mm, is modulated by a Fourier chopper (dia. 400 mm) which is placed inside a massive boron-loaded particle board shielding of 900 mm wall thickness. A thin flat sample (5 mm x dia. 80 mm typically) is mounted on a turntable at a distance of 4 m from the chopper, and the diffracted neutrons are counted by a scintillation detector at 4 m distance from the sample. The scattering angle 2theta can be chosen between 90deg and 160deg to cover Bragg angles from 45deg up to 80deg. The angle between the chopper disc and the incident beam direction as well as the angle of the detector surface relative to the diffracted beam can be adjusted between 45deg and 90deg in order to accomplish time-focusing. In our set-up, with equal flight paths from chopper to sample and from sample to detector, the time-focusing conditions are fulfilled when the chopper and the detector are parallel to the sample-plane. The time-of-flight spectrum of the scattered neutrons is measured by the reverse time-of-flight method in which, instead of neutrons, one essentially records the modulation function of the chopper during constant periods preceding each detected neutron. With a Fourier chopper whose speed is varied in a suitable way, the method is equivalent to the conventional Fourier method but the spectrum is obtained directly without any off-line calculations. The new diffractometer is operated automatically by a Super Nova computer which not only accumulates the synthetized diffraction pattern but also controls the chopper speed according to the modulation frequency sweep chosen by the user to obtain a

  1. The time-of-flight small-angle neutron diffractometer (SAD) at IPNS, Argonne National Laboratory

    International Nuclear Information System (INIS)

    Thiyagarajan, P.; Epperson, J.E.; Crawford, R.K.; Carpenter, J.M.; Klippert, T.E.; Wozniak, D.G.

    1997-01-01

    The design, development and performance of the time-of-flight (TOF) small-angle diffractometer (SAD) at the Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory are described. Similar TOF-SANS instruments are in operation at the pulsed neutron sources at Los Alamos National Laboratory, USA, at Rutherford Appleton Laboratory, England, and at KEK, Japan. These instruments have an advantage by comparison with their steady-state counterparts in that a relatively wide range of momentum transfer (q) can be monitored in a single experiment without the need to alter the collimation or the sample-to-detector distance. This feature makes SANS experiments easy and very effective for studying systems such as those undergoing phase transitions under different conditions, samples that cannot be easily reproduced for repetitive experiments, and systems under high temperature, pressure or shear. Three standard samples are used to demonstrate that the quality of the SANS data from SAD is comparable with those from other established steady-state SANS facilities. Two examples are given to illustrate that the wide q region accessible in a single measurement at SAD is very effective for following the time-dependent phase transitions in paraffins and temperature- and pressure-dependent phase transitions in model biomembranes. (orig.)

  2. Comparison of stroke work between repaired tetralogy of Fallot and normal right ventricular physiologies.

    Science.gov (United States)

    Lee, Namheon; Das, Ashish; Banerjee, Rupak K; Gottliebson, William M

    2013-01-01

    Adult patients who underwent tetralogy of Fallot repair surgery (rTOF) confront life-threatening ailments due to right ventricular (RV) myocardial dysfunction. Pulmonary valve replacement (PVR) needs to be performed to restore the deteriorating RV function. Determination of correct timing to perform PVR in an rTOF patient remains subjective, due to the unavailability of quantifiable clinical diagnostic parameters. The objective of this study is to evaluate the possibility of using RV body surface area (BSA)-indexed stroke work (SW(I)) to quantify RV inefficiency in TOF patients. We hypothesized that RV SW(I) required to push blood to the lungs in rTOF patients is significantly higher than that of normal subjects. Seven patients with rTOF pathophysiology and eight controls with normal RV physiology were registered for this study. Right ventricular volume and pressure were measured using cardiac magnetic resonance imaging and catheterization, respectively. Statistical analysis was performed to quantify the difference in SW(I) between the RV of the rTOF and control groups. Right ventricular SW(I) in rTOF patients (0.176 ± 0.055 J/m(2)) was significantly higher by 93.4% (P = 0.0026) than that of controls (0.091 ± 0.030 J/m(2)). Further, rTOF patients were found to have significantly higher (P < 0.05) BSA normalized RV end-systolic volume, end-systolic pressure, and regurgitation fraction than control subjects. Ejection fraction and peak ejection rate of rTOF patients were significantly lower (P < 0.05) than those of controls. Patients with rTOF pathophysiology had significantly higher RV SW(I) compared with subjects with normal RV physiology. Therefore, RV SW(I) may be useful to quantify RV inefficiency in rTOF patients along with currently used clinical end points such as RV volume, pressure, regurgitation fraction, and ejection fraction.

  3. Automated IBM PC/XT/AT based measurement and control system for the DRON-3M X-ray diffractometer

    International Nuclear Information System (INIS)

    Tulaev, A.B.

    1989-01-01

    An automated IBM PC/XT/AT based measurement and control system for the DRON-3M X-ray diffractometer is decribed. The system permits carrying out of real time diffractometer control automatic X-spectra measurement and data acquisition, as well as experimental information computing and representation. The electronic of the system consists of a CAMAC crate with analog and power modules, and a control and measurement organization module, performed as a single bord in the standard of PC electronics. The system provides X-spectra acquisition with volume up to 4K in the angle range from 100 to 160 degrees with a resolution of 0.01 degree, a dead time less than 1mks and an exposition time from tenths of a second to dozens of minutes. 3 refs.; 5 figs

  4. Universal crystal cooling device for precession cameras, rotation cameras and diffractometers

    International Nuclear Information System (INIS)

    Hajdu, J.; McLaughlin, P.J.; Helliwell, J.R.; Sheldon, J.; Thompson, A.W.

    1985-01-01

    A versatile crystal cooling device is described for macromolecular crystallographic applications in the 290 to 80 K temperature range. It utilizes a fluctuation-free cold-nitrogen-gas supply, an insulated Mylar crystal cooling chamber and a universal ball joint, which connects the cooling chamber to the goniometer head and the crystal. The ball joint is a novel feature over all previous designs. As a result, the device can be used on various rotation cameras, precession cameras and diffractometers. The lubrication of the interconnecting parts with graphite allows the cooling chamber to remain stationary while the crystal and goniometer rotate. The construction allows for 360 0 rotation of the crystal around the goniometer axis and permits any settings on the arcs and slides of the goniometer head (even if working at 80 K). There are no blind regions associated with the frame holding the chamber. Alternatively, the interconnecting ball joint can be tightened and fixed. This results in a set up similar to the construction described by Bartunik and Schubert where the cooling chamber rotates with the crystal. The flexibility of the systems allows for the use of the device on most cameras or diffractometers. THis device has been installed at the protein crystallographic stations of the Synchrotron Radiation Source at Daresbury Laboratory and in the Laboratory of Molecular Biophysics, Oxford. Several data sets have been collected with processing statistics typical of data collected without a cooling chamber. Tests using the full white beam of the synchrotron also look promising. (orig./BHO)

  5. Design of Double PG Crystal Neutron Diffractometer

    International Nuclear Information System (INIS)

    Adib, M.; Habib, N.; El-Mesiry, M.S.; Fathallah, M.

    2011-01-01

    The design of a diffractometer containing two pyrolytic graphite (PG) crystals to select monochromatic neutrons in the range of wavelengths longer than 0.26 nm is given. The first crystal is high oriented pyrolytic graphite (HOPG) set at glancing angle to reflect monochromatic neutrons with a selected wavelength. The second is a low quality PG crystal filter, set at take-off-angle such that, it transmits the selected monochromatic neutrons and rejects the higher order contaminations accompanying the first order reflection. It was shown that, 2 mm thick of PG crystal having 0.30 FWHM on mosaic spread are the optimum parameters of monochromator PG crystal. While the optimum thickness and mosaic spread of the PG crystal filter were selected to have low contamination factor of higher order reflections. The optimum parameters of the PG filter crystal were calculated using the computer package Graphite recently developed in our laboratory. Calculation shows that, 3 cm thick PG filter (20 on mosaic spread) is sufficient to almost eliminate the higher order contaminations accompanying the main monochromatic neutrons with

  6. USB port compatible virtual instrument based automation for x-ray diffractometer setup

    International Nuclear Information System (INIS)

    Jayapandian, J.; Sheela, O.K.; Mallika, R.; Thiruarul, A.; Purniah, B.

    2004-01-01

    Windows based virtual instrument (VI) programs in graphic language simplify the design automation in R and D laboratories. With minimal hardware and maximum support of software, the automation becomes easier and user friendly. A novel design approach for the automation of SIEMENS make x-ray diffractometer setup is described in this paper. The automation is achieved with an indigenously developed virtual instrument program in labVIEW ver.6.0 and with a simple hardware design using 89C2051 micro-controller compatible with PC's USB port for the total automation of the experiment. (author)

  7. A Novel X-ray Diffractometer for the Florida Split Coil 25 Tesla Magnet

    Science.gov (United States)

    Wang, Shengyu; Kovalev, Alexey; Suslov, Alexey; Siegrist, Theo

    2014-03-01

    At National High Magnetic Field Laboratory (NHMFL), we are developing a unique X-ray diffractometer for the 25 Tesla Florida Split Coil Magnet for scattering experiments under extremely high static magnetic fields. The X-ray source is a sealed tube (copper or molybdenum anode), connected to the magnet by an evacuated beam tunnel. The detectors are either an image plate or a silicon drift detector, with the data acquisition system based on LabVIEW. Our preliminary experimental results showed that the performance of the detector electronics and the X-ray generator is reliable in the fringe magnetic fields produced at the highest field of 25 T. Using this diffractometer, we will make measurements on standard samples, such as LaB6, Al2O3 and Si, to calibrate the diffraction system. Magnetic samples, such as single crystal HoMnO3 and stainless steel 301 alloys will be measured subsequently. The addition of X-ray diffraction to the unique split coil magnet will significantly expand the NHMFL experimental capabilities. Therefore, external users will be able to probe spin - lattice interactions at static magnetic fields up to 25T. This project is supported by NSF-DMR Award No.1257649. NHMFL is supported by NSF Cooperative Agreement No. DMR-1157490, the State of Florida, and the U.S. DoE.

  8. The Manuel Lujan, Jr. Neutron Scattering Center (LANSCE) experiment reports, 1991 run cycle

    International Nuclear Information System (INIS)

    DiStravolo, M.A.

    1992-12-01

    This report briefly discusses experiments conducted at the Lansce neutron source facility. The experiments were conducted on the following instruments: high intensity powder diffractometer; neutron powder diffractometer; single crystal diffractometer; low-q diffractometer; surface profile analysis reflectometer; filter difference spectrometer; experiment reports, and pharos

  9. Note: An X-ray powder diffractometer with a wide scattering-angle range of 72° using asymmetrically positioned one-dimensional detectors

    Energy Technology Data Exchange (ETDEWEB)

    Katsuya, Yoshio; Tanaka, Masahiko [Synchrotron X-ray Station at SPring-8, National Institute for Materials Science (NIMS), 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); Song, Chulho [Synchrotron X-ray Station at SPring-8, National Institute for Materials Science (NIMS), 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); Global Research Center for Environment and Energy based Nanomaterials Science (GREEN), Lithium Air Battery Specially Promoted Research Team, NIMS, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Ito, Kimihiko; Kubo, Yoshimi [Global Research Center for Environment and Energy based Nanomaterials Science (GREEN), Lithium Air Battery Specially Promoted Research Team, NIMS, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Sakata, Osami, E-mail: SAKATA.Osami@nims.go.jp [Synchrotron X-ray Station at SPring-8, National Institute for Materials Science (NIMS), 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); Global Research Center for Environment and Energy based Nanomaterials Science (GREEN), Lithium Air Battery Specially Promoted Research Team, NIMS, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Synchrotron X-ray Group, Quantum Beam Unit, NIMS, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan)

    2016-01-15

    An X-ray powder diffractometer has been developed for a time-resolved measurement without the requirement of a scattering angle (2θ) scan. Six one-dimensional detector modules are asymmetrically arranged in a vertical line at a designed distance of 286.5 mm. A detector module actually covers a diffraction angle of about 12° with an angular resolution of 0.01°. A diffracted intensity pattern is simultaneously recorded in a 2θ angular range from 1.63° to 74.37° in a “one shot” measurement. We tested the performance of the diffractometer with reference CeO{sub 2} powders and demonstrated diffraction measurements from an operating lithium-air battery.

  10. Compact femtosecond electron diffractometer with 100 keV electron bunches approaching the single-electron pulse duration limit

    International Nuclear Information System (INIS)

    Waldecker, Lutz; Bertoni, Roman; Ernstorfer, Ralph

    2015-01-01

    We present the design and implementation of a highly compact femtosecond electron diffractometer working at electron energies up to 100 keV. We use a multi-body particle tracing code to simulate electron bunch propagation through the setup and to calculate pulse durations at the sample position. Our simulations show that electron bunches containing few thousands of electrons per bunch are only weakly broadened by space-charge effects and their pulse duration is thus close to the one of a single-electron wavepacket. With our compact setup, we can create electron bunches containing up to 5000 electrons with a pulse duration below 100 fs on the sample. We use the diffractometer to track the energy transfer from photoexcited electrons to the lattice in a thin film of titanium. This process takes place on the timescale of few-hundred femtoseconds and a fully equilibrated state is reached within 1 ps

  11. Application of the X-ray diffractometer DRON to the study of long period structures

    International Nuclear Information System (INIS)

    Gordelij, V.I.; Lushchikov, V.I.; Syrykh, A.G.; Cherezon, V.G.

    1991-01-01

    It is shown that the stock-produced X-ray diffractometer DRON can be adapted for the study of long period structures up to ∼150 A. The experimental data on small-angle diffraction spectra, measured on it, from both lamellar and lateral structures of biological and lipid membranes are reported. The data show that lattice constants of these structures could be determined within the accuracy of 1 A. 15 refs.; 7 figs

  12. Proarrhythmic remodelling of the right ventricle in a porcine model of repaired tetralogy of Fallot

    Science.gov (United States)

    Benoist, David; Dubes, Virginie; Roubertie, François; Gilbert, Stephen H; Charron, Sabine; Constantin, Marion; Elbes, Delphine; Vieillot, Delphine; Quesson, Bruno; Cochet, Hubert; Haïssaguerre, Michel; Rooryck, Caroline; Bordachar, Pierre; Thambo, Jean-Benoit; Bernus, Olivier

    2017-01-01

    Objective The growing adult population with surgically corrected tetralogy of Fallot (TOF) is at risk of arrhythmias and sudden cardiac death. We sought to investigate the contribution of right ventricular (RV) structural and electrophysiological remodelling to arrhythmia generation in a preclinical animal model of repaired TOF (rTOF). Methods and results Pigs mimicking rTOF underwent cardiac MRI functional characterisation and presented with pulmonary regurgitation, RV hypertrophy, dilatation and dysfunction compared with Sham-operated animals (Sham). Optical mapping of rTOF RV-perfused wedges revealed a significant prolongation of RV activation time with slower conduction velocities and regions of conduction slowing well beyond the surgical scar. A reduced protein expression and lateralisation of Connexin-43 were identified in rTOF RVs. A remodelling of extracellular matrix-related gene expression and an increase in collagen content that correlated with prolonged RV activation time were also found in these animals. RV action potential duration (APD) was prolonged in the epicardial anterior region at early and late repolarisation level, thus contributing to a greater APD heterogeneity and to altered transmural and anteroposterior APD gradients in rTOF RVs. APD remodelling involved changes in Kv4.3 and MiRP1 expression. Spontaneous arrhythmias were more frequent in rTOF wedges and more complex in the anterior than in the posterior RV. Conclusion Significant remodelling of RV conduction and repolarisation properties was found in pigs with rTOF. This remodelling generates a proarrhythmic substrate likely to facilitate re-entries and to contribute to sudden cardiac death in patients with rTOF. PMID:28051771

  13. Design and construction of a data acquisition system for a neutron diffractometer

    International Nuclear Information System (INIS)

    Baeza F, Lorena M.

    1995-01-01

    This work presents the design and construction of a data acquisition system for the neutron diffractometer of the La Reina Nuclear Studies Center. The system counts simultaneously the events produced in 17 detection channels, in 128 time channels with 10 μs duration, synchronized with a external signal. The event counting is performed by associating each detection and time channel to a binary code which determine a storage memory. The system is operated by a computer which controls the data acquisition and transfer. The designed software allows the data acquisition and storage in a file for later processing

  14. Software of structure experiMents in a neutron time-of-flight diffractometer

    International Nuclear Information System (INIS)

    Balagurov, A.M.; Dlouga, M.; Zlokazov, V.B.; Mironova, G.M.

    1978-01-01

    A set of programs is discussed to be used in diffraction experiment in a neutron time-of-flight diffractometer. The DIFRAT program, which processes spectra of poly and monocrystals, locates all spectrum maxima and assesses their width on the basis of given experimental data and elementary cell parameters. Accurate location of maxima, evaluation of their area and width is done by the IREAK program. The most important feature of this program is a capability to set an experimental model of maxima patterns. The EXPDAT program is developed to investigate structural characteristics of a sample. It calculates corrections for absorbtion and extinction

  15. The OSIRIS diffractometer and polarisation analysis spectrometer at ISIS. New developments and 3He spin-filter polarisation analysis

    International Nuclear Information System (INIS)

    Andersen, Ken H.; Marero, David Martin y; Barlow, Michael J.

    2001-01-01

    OSIRIS combines a long-wavelength powder diffractometer with a polarisation analysis backscattering spectrometer. The diffractometer can access wavelengths up to 70 A with a resolution of better than 1% Δd/d. The very high counting-rate at shorter wavelengths is ideal for in-situ, real-time and parametric experiments. The spectroscopy section incorporates an array of graphite crystals arranged in near-backscattering to give a high counting rate with 25 μeV energy resolution. The incident beam is polarised using a supermirror bender and the scattered beam is polarisation-analysed by a 3 He spin-filter in the process of being constructed. The spin-filter system consists of a fibre laser, a peristaltic pump and a wide-angle banana-shaped quartz cell in a continuous-flow setup. The scattered beam passes twice through the spin-filter cell, thus doubling the optical path length in the cell. The aim is to achieve 70% nuclear polarisation with no variation in time. (author)

  16. Development of portable X-ray diffractometer equipped with X-ray fluorescence spectrometer and its application to archaeology

    International Nuclear Information System (INIS)

    Yamashita, Daisuke; Ishizaki, Atsushi; Uda, Masayuki

    2009-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to obtain a diffraction pattern and a fluorescence spectrum in air from one and the same small area of a specimen. The reason why the portable XRD with an XRF spectrometer was specially designed for archaeology may be understood from the following facts: (1) some objects exhibited in museums are not allowed to be transferred from the open air to a vacuum, even if their volumes are small; (2) some objects are very difficult to move from their original sites; (3) some parts of exhibits are extremely fragile and cannot be examined in a vacuum; and (4) information on the chemical composition and structure from the same area of an object offers a better understanding of the constitutive materials of the object. Some examples of the use of a portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer in the field are also introduced. Experimental results of Sho-kannon, Snew's mask and Tutankhamun's golden mask are shown here. (author)

  17. Neutron diffractometer for bio-crystallography (BIX) with an imaging plate neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Niimura, Nobuo [Japan Atomic Energy Research Inst., Ibaraki-ken (Japan)

    1994-12-31

    We have constructed a dedicated diffractometer for neutron crystallography in biology (BIX) on the JRR-3M reactor at JAERI (Japan Atomic Energy Research Institute). The diffraction intensity from a protein crystal is weaker than that from most inorganic materials. In order to overcome the intensity problem, an elastically bent silicon monochromator and a large area detector system were specially designed. A preliminary result of diffraction experiment using BIX has been reported. An imaging plate neutron detector has been developed and a feasibility experiment was carried out on BIX. Results are reported. An imaging plate neutron detector has been developed and a feasibility test was carried out using BIX.

  18. The D18 diffractometer for neutron interferometry at the I.L.L

    International Nuclear Information System (INIS)

    Bauspiess, W.

    1978-01-01

    Three things are needed for neutron interferometry: an interferometer (a crystal in the case of Bragg diffraction interferometry), a neutron source, and a device to select and handle the neutrons that shall be used. It is this last technical aspect of neutron interferometry which is discussed in the paper, using as an example the new diffractometer for neutron interferometry that is being built at the I.L.L. Results of performance tests are not presently available but its characteristics are visible from the design. The experimental figures given in the paper refer to experiments performed with the prototype machine, or are extrapolated from said experiments

  19. DREAM — a versatile powder diffractometer at the ESS

    International Nuclear Information System (INIS)

    Schweika, W; Violini, N; Lieutenant, K; Nekrassov, D; Zendler, C; Henry, P F; Houben, A; Jacobs, P

    2016-01-01

    The instrument DREAM, in construction at the long pulse European Spallation Source (ESS), is a new type of neutron time-of-flight powder diffractometer, which utilizes additional choppers to meet the typical high resolution requests. Pulses will be of symmetric shape and their width can be varied from 10 μs to 1 ms, providing an unprecedented flexibility from highest to low resolution with optimized intensities at the superior brightness of the 5 MW source. The design is driven particularly by the needs and challenges for small and complex samples, large unit cell materials, thermoelectric cage structures or metal-organic framework structures, multiphase battery materials and complex magnetic structures. Therefore, the chosen wavelength bandwidth of 3.7 Å may cover well the peak intensities of the thermal and cold moderator used simultaneously and provides a sufficient Q (and d ) range for obtaining diffraction patterns in a single setting. VITESS simulations show a performance that is about two orders of magnitude higher than current best instruments. (paper)

  20. Evaluation by MRA of aortic dilation late after repair of tetralogy of Fallot.

    Science.gov (United States)

    Kay, W Aaron; Cook, Stephen C; Daniels, Curt J

    2013-09-10

    This study evaluated predictors for aortic dilation (AD) in patients with repaired tetralogy of Fallot (rTOF) using magnetic resonance angiography (MRA). AD is common in patients with rTOF and may result in increased morbidity and mortality. There are no guidelines for evaluation of AD for rTOF patients. All adults with rTOF who previously underwent MRA had retrospective aortic measurements at the sinuses of Valsalva (SoV) and ascending aorta (AsAo). Rate of change in diameter was determined in patients with multiple MRAs. Chart review identified risk factors for AD. Univariate and multivariate analyses tested predictors of AD. Of the 87 patients who met the inclusion criteria, 12 (14%) had AD. At baseline, mean diameter was 3.6 ± 0.6 cm and 3.1 ± 0.6 cm at the SoV and AsAo, respectively. The AsAo was larger than the SoV in 17%. Predictors of AD included male gender, age, right aortic arch, pregnancy, older age at complete repair, smoking, and systemic hypertension. Serial studies were available in 55 patients; the rate of growth was slow: 0.4 ± 0.9 mm/year (SoV) and 0.1 ± 0.8mm/year (AsAo). AD is common in rTOF at the SoV and AsAo. Transthoracic echocardiography, which does not always image the AsAo as well as MRA, may not image AD in rTOF in cases in which the AsAo is dilated. Although several risk factors correlate with AD in rTOF, the rate of aortic growth is slow, suggesting that rTOF patients may not require frequent aortic imaging. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. A Novel Dual Air-Bearing Fixed-χ Diffractometer for Small-Molecule Single-Crystal X-ray Diffraction on Beamline I19 at Diamond Light Source

    Directory of Open Access Journals (Sweden)

    David . R Allan

    2017-11-01

    Full Text Available Herein, we describe the development of a novel dual air-bearing fixed-χ diffractometer for beamline I19 at Diamond Light Source. The diffractometer is designed to facilitate the rapid data collections possible with a Dectris Pilatus 2M pixel-array photon-counting detector, while allowing remote operation in conjunction with a robotic sample changer. The sphere-of-confusion is made as small as practicably possible, through the use of air-bearings for both the ω and φ axes. The design and construction of the new instrument is described in detail and an accompanying paper by Johnson et al. (also in this issue will provide a user perspective of its operation.

  2. A temperature-controlled cell for X-ray study of liquid systems using a commercial DRON-UM1 diffractometer

    International Nuclear Information System (INIS)

    Petrun'kin, S.P.; Garavina, E.V.; Trostin, V.N.

    1995-01-01

    A container (cell) and a temperature-control system have been designed enabling one to carry out x-ray diffraction study of liquid samples both at a fixed temperature and within a certain temperature range using a commercial DRON-UMl x-ray diffractometer. Special features of the cell and the materials used for it allow one to study both chemically inert and corrosive liquids

  3. Detector for the FSD Fourier-diffractometer based on ZnS(Ag)/6LiF scintillation screen and wavelength shifting fibers readout

    International Nuclear Information System (INIS)

    Kuz'min, E.S.; Balagurov, A.M.; Bokuchava, G.D.; Zhuk, V.V.; Kudryashev, V.A.; Bulkin, A.P.; Trunov, V.A.

    2001-01-01

    At the IBR-2 pulsed reactor (FLNP, JINR, Dubna), a specialized time-of-flight instrument Fourier-Stress-Diffractometer (FSD) intended for the measurement of internal stresses in bulk samples by using high-resolution neutron diffraction is under construction. One of the main components of the diffractometer is a new-type detector with combined electronic - geometrical focusing uniting a large solid angle and a small geometry contribution to the instrumental resolution. The first two modules of the detector, based on scintillation screen ZnS(Ag)/ 6 LiF with wavelength shifting fibers readout have been developed and tested. The design of the detector and associated electronics are described. The method of time focusing surface approximation, using the screen flexibility is proposed. Characteristics of the tested modules in comparison with a detector of the previous generation are presented and advantages of the new detector design for high-resolution diffractometry are discussed

  4. Automation of angular movement of the arm neutron diffractometer; Automatizacion del movimiento angular del brazo del difractometro de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F.; Herrera A, E.; Quintana C, G. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Torres R, C. E.; Reyes V, M., E-mail: fortunato.aguilar@inin.gob.mx [Instituto Tecnologico de Toluca, Av. Tecnologico s/n, Ex-Rancho La Virgen, Metepec, Estado de Mexico (Mexico)

    2015-09-15

    A technique to determine the crystal structure of some materials is the neutron diffraction. This technique consists on placing the material in question in a monoenergetic neutron beam obtained by neutron diffraction in a monochromator crystal. The neutron energy depends of the diffraction angle. The Instituto Nacional de Investigaciones Nucleares has a neutron diffractometer and monochromator crystals of pyrolytic graphite. This crystal can be selecting the neutron energy depending on the angle of diffraction in the glass. The radiation source for the neutron diffractometer is the TRIGA Mark III reactor of the Nuclear Center Dr. Nabor Carrillo Flores. During their operation are also obtained besides neutrons, β and γ radiation. The interest is to have thermal neutrons, so fast neutrons and γ rays are removed using appropriate shielding. The average neutron fluxes of the radial port RE2 of neutron diffractometer at power 1 MW are: heat flow 2,466 x 10{sup 8} n cm{sup -2} sec{sup -1} and fast flow 1,239 x 10{sup 8} n cm{sup -2} sec{sup -1}. The neutron detector is housed in a shield mounted on a mechanical linkage with which the diffraction angle is selected, and therefore the energy of the neutrons. The movement of this joint was performed by the equipment operator manually, so that accuracy to select the diffraction angle was not good and the process rather slow. Therefore a mechanical system was designed, automated by means of a motor as an actuator, a system of force transmission and an electronic control in order that the operator will schedule the diffraction angles and allow the count in the neutrons detection system in a simple manner. (Author)

  5. The Manuel Lujan, Jr. Neutron Scattering Center LANSCE experiment reports 1989 run cycle

    Energy Technology Data Exchange (ETDEWEB)

    Hyer, D.K.; DiStravolo, M.A. (comps.)

    1990-10-01

    This report contains a listing and description of experiments carried on at the LANSCE neutron scattering facility in the following areas: High Density Powder Diffraction; Neutron Powder Diffractometer, (NPD); Single Crystal Diffractometer, (SCD); Low-Q Diffractometer, (LQD); Surface Profile Analysis Reflectometer, (SPEAR); Filter Difference Spectrometer, (FDS); and Constant-Q Spectrometer.

  6. The Manuel Lujan, Jr. Neutron Scattering Center LANSCE experiment reports 1989 run cycle

    International Nuclear Information System (INIS)

    Hyer, D.K.; DiStravolo, M.A.

    1990-10-01

    This report contains a listing and description of experiments carried on at the LANSCE neutron scattering facility in the following areas: High Density Powder Diffraction; Neutron Powder Diffractometer, (NPD); Single Crystal Diffractometer, (SCD); Low-Q Diffractometer, (LQD); Surface Profile Analysis Reflectometer, (SPEAR); Filter Difference Spectrometer, (FDS); and Constant-Q Spectrometer

  7. Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang-Soon; Han, Sun-Ho; Kim, Jong-Goo; Jee, Kwang-Yong; Kim, Won-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2006-10-15

    An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-SRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at 5 {mu}m steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was 4,000 x 20{mu}m and the spatial resolution of the beam was 47 {mu}m at the sample position. When the diffraction peaks were measured for a UO{sub 2} pellet specimen by this system, the reproducibility (2{theta} = {+-}0.01 .deg.) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only TiO{sub 2} in an outer layer but also TiO near an oxide-metal interface was observed.

  8. Automatic attenuator upgrade for a Siemens D500 diffractometer via a generic software library to overcome hardware limitations

    International Nuclear Information System (INIS)

    Mayr, Sina; Randau, Christian; Kreuzpaintner, Wolfgang

    2017-01-01

    A proxy software was developed which allows the Siemens D500 x-ray diffractometer to be upgraded with add-ons that have never been officially available for it. For demonstration, we designed and integrated an automatic attenuator option and demonstrated the feasibility of our upgrade path by typical comparative x-ray measurements, which would usually saturate the x-ray detector, if no attenuator is used.

  9. Automatic attenuator upgrade for a Siemens D500 diffractometer via a generic software library to overcome hardware limitations

    Energy Technology Data Exchange (ETDEWEB)

    Mayr, Sina, E-mail: sina.mayr@frm2.tum.de [Technische Universität München, Physik-Department E21, James-Franck-Str. 1, 85748 Garching (Germany); Randau, Christian [Georg-August-Universität Göttingen, Fakultät für Geowissenschaften und Geologie, Abteilung Isotopengeologie Außenstelle MLZ (FRM II), Lichtenbergstr. 1, 85748 Garching (Germany); Kreuzpaintner, Wolfgang [Technische Universität München, Physik-Department E21, James-Franck-Str. 1, 85748 Garching (Germany)

    2017-05-21

    A proxy software was developed which allows the Siemens D500 x-ray diffractometer to be upgraded with add-ons that have never been officially available for it. For demonstration, we designed and integrated an automatic attenuator option and demonstrated the feasibility of our upgrade path by typical comparative x-ray measurements, which would usually saturate the x-ray detector, if no attenuator is used.

  10. Report on the workshop on neutrons for engineering and its conclusions regarding the residual-stress diffractometer at the Australian Replacement Research Reactor

    International Nuclear Information System (INIS)

    2002-01-01

    The purpose of the workshop was to: inform the Australian research organizations and universities of the capabilities of an engineering and materials science instrument; promote the use of neutron diffraction to map and investigate strains/stresses in materials and components for industrial applications and research; identify the future needs and opportunities in this area; present the options for a stress mapping diffractometer at the Replacement Research Reactor and receive feedback on these options; identify the ancillary equipment and facilities required. Presented papers and discussions at the workshop indicated that there are a number of important benefits to Australia in the building of a first-class instrument for materials science and engineering and many residual stress-related problems in a wide variety of fields in Australia, such as the manufacturing industries, mining, oil and gas, rail transport, defense and life extension. Stress scanning provides another tool for solving problems to complement facilities at the major research institutes, CSIRO, AMIRA, DSTO, ANSTO and the universities. It will create a regional pool of experts who may tap into the pool of expertise internationally. The turn around time for tests for Australian customers will be reduced thus avoiding having to go overseas to have the tests performed. From an educational perspective the instrument will build expertise in Australia and will help to attract graduates into engineering. A detailed list of the attendees and affiliations is in Appendix C

  11. Better powder diffractometers. II—Optimal choice of U, V and W

    Science.gov (United States)

    Cussen, L. D.

    2007-12-01

    This article presents a technique for optimising constant wavelength (CW) neutron powder diffractometers (NPDs) using conventional nonlinear least squares methods. This is believed to be the first such design optimisation for a neutron spectrometer. The validity of this approach and discussion should extend beyond the Gaussian element approximation used and also to instruments using different radiation, such as X-rays. This approach could later be extended to include vertical and perhaps horizontal focusing monochromators and probably other types of instruments such as three axis spectrometers. It is hoped that this approach will help in comparisons of CW and time-of-flight (TOF) instruments. Recent work showed that many different beam element combinations can give identical resolution on CW NPDs and presented a procedure to find these combinations and also find an "optimum" choice of detector collimation. Those results enable the previous redundancy in the description of instrument performance to be removed and permit a least squares optimisation of design. New inputs are needed and are identified as the sample plane spacing ( dS) of interest in the measurement. The optimisation requires a "quality factor", QPD, chosen here to be minimising the worst Bragg peak separation ability over some measurement range ( dS) while maintaining intensity. Any other QPD desired could be substituted. It is argued that high resolution and high intensity powder diffractometers (HRPDs and HIPDs) should have similar designs adjusted by a single scaling factor. Simulated comparisons are described suggesting significant improvements in performance for CW HIPDs. Optimisation with unchanged wavelength suggests improvements by factors of about 2 for HRPDs and 25 for HIPDs. A recently quantified design trade-off between the maximum line intensity possible and the degree of variation of angular resolution over the scattering angle range leads to efficiency gains at short wavelengths. This

  12. Use of a CCD-based area detection system of a fibre diffractometer

    International Nuclear Information System (INIS)

    Hanna, S.; Windle, A.H.

    1995-01-01

    We describe a new X-ray fibre diffractometer, consisting of a commercial X-ray sensitive video camera coupled to a conventional 3 goniometer in place of a more traditional single-point detector. The active element of the video camera is a charge-coupled device (CCD). Diffraction images, obtained at various goniometer settings, are transformed into reciprocal space, and combined to give a complete section through the origin and parallel to the symmetry axis of cylindrically averaged reciprocal space. A greater density of measurements is needed in the vicinity of the reciprocal fibre axis in order to avoid information loss due to the curvature of the Ewald sphere. The pros and cons of using CCD's as X-ray detectors are discussed and sample results from polymer fibers are shown. 17 refs., 5 figs

  13. Measurement of the neutron intensity data using the HANARO four circle diffractometer

    International Nuclear Information System (INIS)

    Lee, Jin Ho; Lee, Chang Hee; Seong, Baek Seok; Lee, Jeong Soo; Shim, Hae Seop; Hong, Kwang Pyo; Song, Su Ho; Suh, Il Hwan

    1999-04-01

    As the four circle diffractometer(FCD) has been set up in HANARO, it has become possible to study single crystal structures by means of the neutron diffraction. By introducing the constitution and characteristics of FCD, it has been shown that the feature of neutron diffraction experiment are different from that of X-ray or electronic beam. Besides we have explained the processes of determining experimental information in order to acquire intensity data and constructed the experimental system based on geometry of the FCD. As the computer programme performing all experimental processes automatically has been installed and the accuracy of experimental processes were confirmed by KCl single crystal experiment, the original experimental system for single crystal experiments and analyses by the neutron diffraction method using FCD has been established. (Author). 12 refs., 2 tabs., 11 figs

  14. HIPPO, the high-pressure preferred orientation diffractometer at LANSCE for characterization of bulk materials

    International Nuclear Information System (INIS)

    Bennett, K.; Dreele, R.B. von; Wenk, H.R.

    2001-01-01

    United States National Laboratory researchers and University of California faculty, representing a broad range of scientific disciplines, is building a novel time-of-flight (TOF) neutron diffractometer and associated in situ equipment at the Manuel Lujan Jr. Neutron Scattering Center (Lujan Center), under the auspices of the United States Department of Energy. The goal with the High-Pressure Preferred Orientation Instrument (HIPPO) is to investigate dynamic processes in heterogeneous bulk materials in a variety of environments. The instrument, which will become available in summer 2001, has the extremely high count-rates necessary to study time-dependent processes in small (1-mm diameter) and large (2-cm diameter) samples, and in a large variety of environmental conditions (10-2000 K cryostats and furnaces, 0-20 GPa pressure vessels, straining cells, goniometers, magnets, etc.). The 3-D arrangement of detectors allows direct measurements of crystal orientation distributions in polycrystalline materials. The analysis of TOF diffraction patterns with versatile Rietveld codes provides simultaneous information on crystal structure, texture, microstructure and phase proportions. While this instrument has many applications in materials science, it is also of great interest for geology and geophysics. Some applications include: kinetics of reactions, structure of silicate glasses and melts, high-pressure investigations of complex systems, evolution of texture and anisotropy during deformation and recrystallization. The Lujan Center aims at creating an instrument with high data through-put and easy access to researchers and students. While the HIPPO instrument will be part of the national user facility operated by the Lujan Center, the scientific program will be guided by the University of California consortium with the goal of satisfying national priorities and establishing an environment of scientific excellence. (author)

  15. HIPPO, the high-pressure preferred orientation diffractometer at LANSCE for characterization of bulk materials

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, K.; Dreele, R.B. von [Manuel Lujan Jr. Neutron Scattering Center, Los Alamos, NM (United States); Wenk, H.R. [Department of Geology and Geophysics, Univ. of California, Berkely, CA (United States)

    2001-03-01

    United States National Laboratory researchers and University of California faculty, representing a broad range of scientific disciplines, is building a novel time-of-flight (TOF) neutron diffractometer and associated in situ equipment at the Manuel Lujan Jr. Neutron Scattering Center (Lujan Center), under the auspices of the United States Department of Energy. The goal with the High-Pressure Preferred Orientation Instrument (HIPPO) is to investigate dynamic processes in heterogeneous bulk materials in a variety of environments. The instrument, which will become available in summer 2001, has the extremely high count-rates necessary to study time-dependent processes in small (1-mm diameter) and large (2-cm diameter) samples, and in a large variety of environmental conditions (10-2000 K cryostats and furnaces, 0-20 GPa pressure vessels, straining cells, goniometers, magnets, etc.). The 3-D arrangement of detectors allows direct measurements of crystal orientation distributions in polycrystalline materials. The analysis of TOF diffraction patterns with versatile Rietveld codes provides simultaneous information on crystal structure, texture, microstructure and phase proportions. While this instrument has many applications in materials science, it is also of great interest for geology and geophysics. Some applications include: kinetics of reactions, structure of silicate glasses and melts, high-pressure investigations of complex systems, evolution of texture and anisotropy during deformation and recrystallization. The Lujan Center aims at creating an instrument with high data through-put and easy access to researchers and students. While the HIPPO instrument will be part of the national user facility operated by the Lujan Center, the scientific program will be guided by the University of California consortium with the goal of satisfying national priorities and establishing an environment of scientific excellence. (author)

  16. Neutron diffractometers for structural biology at spallation neutron sources

    International Nuclear Information System (INIS)

    Schoenborn, B.P.; Pitcher, E.

    1994-01-01

    Spallation neutron sources are ideal for diffraction studies of proteins and oriented molecular complexes. With spoliation neutrons and their time dependent wavelength structure, it is easy to electronically select data with an optimal wavelength bandwidth and cover the whole Laue spectrum as time (wavelength) resolved snapshots. This optimized data quality with best peak-to-background ratios and provides adequate spatial and energy resolution to eliminate peak overlaps. The application of this concept will use choppers to select the desired Laue wavelength spectrum and employ focusing optics and large cylindrical 3 He detectors to optimize data collection rates. Such a diffractometer will cover a Laue wavelength range from 1 to 5 Angstrom with a flight path length of 10m and an energy resolution of 0.25 Angstrom. Moderator concepts for maximal flux distribution within this energy range will be discussed using calculated flux profiles. Since the energy resolution required for such timed data collection in this super Laue techniques is not very high, the use of a linac only (LAMPF) spoliation target is an exciting possibility with an order of magnitude increase in flux

  17. Neutron diffractometers for structural biology at spallation neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Schoenborn, B.P.; Pitcher, E. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Spallation neutron sources are ideal for diffraction studies of proteins and oriented molecular complexes. With spoliation neutrons and their time dependent wavelength structure, it is easy to electronically select data with an optimal wavelength bandwidth and cover the whole Laue spectrum as time (wavelength) resolved snapshots. This optimized data quality with best peak-to-background ratios and provides adequate spatial and energy resolution to eliminate peak overlaps. The application of this concept will use choppers to select the desired Laue wavelength spectrum and employ focusing optics and large cylindrical {sup 3}He detectors to optimize data collection rates. Such a diffractometer will cover a Laue wavelength range from 1 to 5{Angstrom} with a flight path length of 10m and an energy resolution of 0.25{Angstrom}. Moderator concepts for maximal flux distribution within this energy range will be discussed using calculated flux profiles. Since the energy resolution required for such timed data collection in this super Laue techniques is not very high, the use of a linac only (LAMPF) spoliation target is an exciting possibility with an order of magnitude increase in flux.

  18. Sensitivity of triple-crystal X-ray diffractometers to microdefects in silicon

    International Nuclear Information System (INIS)

    Molodkin, V.B.; Olikhovskii, S.I.; Len, E.G.; Kislovskii, E.N.; Kladko, V.P.; Reshetnyk, O.V.; Vladimirova, T.P.; Sheludchenko, B.V.

    2009-01-01

    The dynamical theory, which describes both diffraction profiles and reciprocal space maps measured from imperfect crystals with account for instrumental factors of triple-crystal diffractometer (TCD), has been developed for adequate quantitative characterization of microdefects. Analytical expressions for coherent and diffuse scattering (DS) intensities measured by TCD in the Bragg diffraction geometry have been derived by using the generalized statistical dynamical theory of X-ray scattering in real single crystals with randomly distributed defects. The DS intensity distributions from single crystals containing clusters and dislocation loops have been described by explicit analytical expressions. Particularly, these expressions take into account anisotropy of displacement fields around defects with discrete orientations. Characteristics of microdefect structures in silicon single crystals grown by Czochralsky- and float-zone methods have been determined by analyzing the measured TCD profiles and reciprocal space maps. The sensitivities of reciprocal space maps and diffraction profiles to defect characteristics have been compared. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  19. Left ventricular regional myocardial motion and twist function in repaired tetralogy of Fallot evaluated by magnetic resonance tissue phase mapping

    International Nuclear Information System (INIS)

    Chang, Meng-Chu; Peng, Hsu-Hsia; Wu, Ming-Ting; Weng, Ken-Pen; Su, Mao-Yuan; Menza, Marius; Huang, Hung-Chieh

    2018-01-01

    We aimed to characterise regional myocardial motion and twist function in the left ventricles (LV) in patients with repaired tetralogy of Fallot (rTOF) and preserved LV global function. We recruited 47 rTOF patients and 38 age-matched normal volunteers. Tissue phase mapping (TPM) was performed for evaluating the LV myocardial velocity in longitudinal, radial, and circumferential (Vz, Vr, and VOe) directions in basal, middle, and apical slices. The VOe peak-to-peak (PTP) during systolic phases, the rotation angle of each slice, and VOe inconsistency were computed for evaluating LV twist function and VOe dyssynchrony. As compared to the controls, the rTOF patients presented decreased RV ejection fraction (RVEF) (p = 0.002) and preserved global LV ejection fraction (LVEF). They also demonstrated decreased systolic and diastolic Vz in several LV segments and higher diastolic Vr in the septum (all p < 0.05). A lower VOe PTP, higher VOe inconsistency, and reduced peak net rotation angle (all p < 0.05) were observed. The aforementioned indices demonstrated an altered LV twist function in rTOF patients in an early disease stage. MR TPM could provide information about early abnormalities of LV regional motion and twist function in rTOF patients with preserved LV global function. (orig.)

  20. Left ventricular regional myocardial motion and twist function in repaired tetralogy of Fallot evaluated by magnetic resonance tissue phase mapping

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Meng-Chu; Peng, Hsu-Hsia [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Wu, Ming-Ting [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (China); National Yang-Ming University, Faculty of Medicine, Taipei (China); Weng, Ken-Pen [National Yang-Ming University, Faculty of Medicine, Taipei (China); Kaohsiung Veterans General Hospital, Department of Pediatrics, Kaohsiung (China); Shu-Zen Junior College of Medicine and Management, Department of Physical Therapy, Kaohsiung (China); Su, Mao-Yuan [National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Menza, Marius [Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Department of Radiology, Medical Physics, Freiburg (Germany); Huang, Hung-Chieh [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (China)

    2018-01-15

    We aimed to characterise regional myocardial motion and twist function in the left ventricles (LV) in patients with repaired tetralogy of Fallot (rTOF) and preserved LV global function. We recruited 47 rTOF patients and 38 age-matched normal volunteers. Tissue phase mapping (TPM) was performed for evaluating the LV myocardial velocity in longitudinal, radial, and circumferential (Vz, Vr, and VOe) directions in basal, middle, and apical slices. The VOe peak-to-peak (PTP) during systolic phases, the rotation angle of each slice, and VOe inconsistency were computed for evaluating LV twist function and VOe dyssynchrony. As compared to the controls, the rTOF patients presented decreased RV ejection fraction (RVEF) (p = 0.002) and preserved global LV ejection fraction (LVEF). They also demonstrated decreased systolic and diastolic Vz in several LV segments and higher diastolic Vr in the septum (all p < 0.05). A lower VOe PTP, higher VOe inconsistency, and reduced peak net rotation angle (all p < 0.05) were observed. The aforementioned indices demonstrated an altered LV twist function in rTOF patients in an early disease stage. MR TPM could provide information about early abnormalities of LV regional motion and twist function in rTOF patients with preserved LV global function. (orig.)

  1. Neutron beam applications - Development of operational techniques for neutron four-circle diffractometer and structure determination of C{sub 16}H{sub 15}NO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moon Jib [Soonchunhyang University, Asan (Korea); Suh, Il Hwan [Chungnam National University, Taejon (Korea)

    1999-06-01

    We have been studied to find out the experimental methods and procedures for neutron diffraction method for neutron diffractometer in HANARO -the atomic research reactor in KAERI. We have studied experimental process for the neutron diffraction data analysis, using computer soft-wares such as SHELXS for the calculation the initial phase of crystal structure, SHELXL for refinement of atomic coordinate using least-squares method, ORTEP for the display of the calculated positions of molecule, and PATSEE for the calculation of the phase from the expected structure. In these studies, we analyzed the structure of test sample using these programs, and prepare the user's manual for these soft-wares. We have also studied on bending effect of monochromator in order to increase the intensity of neutron beam, and designed HRPD - High Resolution Powder Diffractometers. 7 refs., 6 figs. (Author)

  2. A design for a high resolution very-low-Q time-of flight diffractometer

    International Nuclear Information System (INIS)

    Hjelm, R. P.

    1998-01-01

    The design of a high resolution view low-Q time of flight diffractometer was motivated by the anticipated need to perform small-angle neutron scattering measurements at far lower momentum transfer and higher precision than currently available at either pulsed or steady state sources. In addition, it was recognized that flexibility in the configuration of the instrument and ease in which data is acquired are important. The design offers two configurations, a high intensity/very low Q geometry employing a focusing mirror and a medium to high Q-precision/low Q configuration using standard pinhole collimation geometry. The quality of the mirror optics is very important to the performance of the high intensity/very low Q configuration. We believe that the necessary technology exists to fabricate the high quality mirror optics required for the instrument

  3. OCTOPUS: an innovative multimodal diffractometer for neutron macromolecular crystallography across the length scales

    International Nuclear Information System (INIS)

    Blakeley, M.P.; Andersen, K.; Kreuz, M.; Giroud, B.; McSweeney, S.; Mitchell, E.; Teixeira, S.C.M.; Forsyth, V.T.

    2011-01-01

    We propose to construct a novel protein diffractometer at position H112B. The new instrument will deliver major efficiency gains, as well as offering greatly extended flexibility through the option of several easily interchangeable modes of operation. This proposal builds on the demonstrable need to extend ILL's capacity for high resolution structural studies of protein systems, as well as a need to widen the scope of biological crystallography - in particular for monochromatic studies at both high and low resolution. The development will be carried out in close collaboration with structural biologists at the ESRF, and engineered in such a way that the user interface of the instrument (from sample to software) will be transparently identifiable to a large, dynamic, and driven community of European synchrotron X-ray macromolecular crystallographers. (authors)

  4. The new powder diffractometer D1B of the Institut Laue Langevin

    Science.gov (United States)

    Puente Orench, I.; Clergeau, J. F.; Martínez, S.; Olmos, M.; Fabelo, O.; Campo, J.

    2014-11-01

    D1B is a medium resolution high flux powder diffractometer located at the Institut Laue Langevin, ILL. D1B a suitable instrument for studying a large variety of polycrystalline materials. D1B runs since 1998 as a CRG (collaborating research group) instrument, being exploited by the CNRS (Centre National de la Recherche Scientifique, France) and CSIC (Consejo Superior de Investigaciones Cientificas, Spain). In 2008 the Spanish CRG started an updating program which included a new detector and a radial oscillating collimator (ROC). The detector, which has a sensitive height of 100mm, covers an angular range of 128°. Its 1280 gold wires provide a neutron detection point every 0.1°. The ROC is made of 198 gadolinium- based absorbing collimation blades, regular placed every 0.67°. Here the present characteristics of D1B are reviewed and the different experimental performances will be presented.

  5. Environmental Modeling Center / Marine Modeling and Analysis Branch

    Science.gov (United States)

    weather and climate. Both have a history. Marine Meteorology Group Products Ocean Winds - Satellite Remote announcement list for changes to our products and services. SDM Contact Notes: Ocean Models -- Avichal Mehra Ocean Waves Sea Ice SST Marine Met. Real Time Ocean Forecasting System (RTOFS) Global RTOFS A hybrid

  6. Abnormalities in Left Ventricular Rotation Are Inherent in Young Children with Repaired Tetralogy of Fallot and Are Independent of Right Ventricular Dilation.

    Science.gov (United States)

    Karnik, Ruchika; Uppu, Santosh C; Tozzi, Meghan; Doucette, John; Lytrivi, Irene D; Geiger, Miwa; Klas, Berthold; Parness, Ira A; Shenoy, Rajesh; Rajagopal, Hari; Srivastava, Shubhika

    2018-04-11

    Left ventricular (LV) dysfunction is a risk factor for adverse outcomes in older children and adults with repaired Tetralogy of Fallot (rToF). Pulmonary regurgitation (PR), right ventricular (RV) dilation, and dysfunction have been shown to result in abnormal LV myocardial mechanics and dysfunction. The aim of our study was to evaluate LV rotational mechanics, especially apical rotation in young children with rToF with and without RV dilation. This is a retrospective, single center study in 28 asymptomatic young children with rToF (16 with RV dilation; 12 without RV dilation); 29 age-matched normal controls. RV and LV systolic and diastolic function was studied using conventional two-dimensional echocardiography (2DE) and speckle tracking echocardiography (STE). Rotational mechanics studied included basal and apical rotation (BR, AR), peak twist (calculated by difference between the apical and basal rotation), twist rate (TR), and untwist rate (UnTR). The mean age of the cohort was 4.7 years (± 2.3). Abnormal AR, BR, TR, and UnTR were noted in patients with rToF. The abnormalities were significant in magnitude as well as the direction of rotation; more pronounced in the absence of RV dilation. LV systolic and diastolic dysfunction as evidenced by abnormal AR and degree of untwist is inherent in rToF and not associated with RV dilation in rToF children. Abnormal BR may reflect a lack of maturation to adult type of rotational mechanics. Further longitudinal studies are required to study the progression of these abnormalities and their correlation with clinical outcomes.

  7. Determination of the zero in the Two theta angle and the wavelength in the neutron diffractometer for the Cyber computer of the ININ and for the IBM compatible microcomputers

    International Nuclear Information System (INIS)

    Macias B, L.R.

    1991-05-01

    The objective of this work consists on determining the calibration in the angular parameters and the neutron wavelength used in the neutron diffractometer of the TRIGA Mark III reactor, through some readings in that a well-known sample is used by means of a Fortran computer program that is used in the CYBER computer of the ININ in Mexico, and/or in micro computers compatible with IBM. The program was also designed to determine the zero of the 2 θ angle of the goniometer of the diffractometer. The generated data were proven by means of well-known data of the Powder Diffraction File of the Joint Committee on Powder Diffraction Standards (JCPDS). (Author)

  8. Note: Detector collimators for the nanoscale ordered materials diffractometer instrument at the Spallation Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Tamalonis, A. [Materials Development, Inc., Arlington Heights, Illinois 60004 (United States); Weber, J. K. R., E-mail: rweber@anl.gov; Alderman, O. L. G. [Materials Development, Inc., Arlington Heights, Illinois 60004 (United States); Argonne National Laboratory, Argonne, Illinois 60439 (United States); Neuefeind, J. C.; Carruth, J. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Skinner, L. B. [Materials Development, Inc., Arlington Heights, Illinois 60004 (United States); Argonne National Laboratory, Argonne, Illinois 60439 (United States); Stony Brook University, Stony Brook, New York 11794 (United States); Benmore, C. J. [Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2015-09-15

    Five neutron collimator designs were constructed and tested at the nanoscale ordered materials diffractometer (NOMAD) instrument. Collimators were made from High Density PolyEthylene (HDPE) or 5% borated HDPE. In all cases, collimators improved the signal to background ratio and reduced detection of secondary scattering. In the Q-range 10-20 Å{sup −1}, signal to background ratio improved by factors of approximately 1.6 and 2.0 for 50 and 100 mm deep collimators, respectively. In the Q-range 40-50 Å{sup −1}, the improvement factors were 1.8 and 2.7. Secondary scattering as measured at Q ∼ 9.5 Å{sup −1} was significantly decreased when the collimators were installed.

  9. Design and performance of a gamma-ray diffractometer at 0.12A

    International Nuclear Information System (INIS)

    Alkire, R.W.

    1982-01-01

    Gamma-ray diffractometry is a relatively new field in which radioisotopes are used to provide highly penetrating, monoenergetic radiation for diffraction experiments. The first part of this work details the design of a gamma-ray diffractometer using the 103 keV gamma-rays from 153 Sm (γ = 0.12A). Complete description of source material, transport cask, full circle, detector and associated electronics is presented along with alignment and testing procedures. The second part of this work covers theoretical advantages and disadvantages afforded by 0.12A radiation, and experimental capabilities are tested by determining the absolute structure factor for the forbidden 222 reflection in silicon. F(222) was determined to be 1.456 +- 0.008 which is in excellent agreement with previous studies but with a reduction in error of between two and ten. General applications of 0.12A gamma radiation are also explored, including mosaic characterizations, structural phase transformations, electron density mapping, powder diffraction and experiments in special environmental devices

  10. Computer-guided facility for the study of single crystals at the gamma diffractometer GADI

    International Nuclear Information System (INIS)

    Heer, H.; Bleichert, H.; Gruhn, W.; Moeller, R.

    1984-10-01

    In the study of solid-state properties it is in many cases necessary to work with single crystals. The increased requirement in the industry and research as well as the desire for better characterization by means of γ-diffractometry made it necessary to improve and to modernize the existing instrument. The advantages of a computer-guided facility against the conventional, semiautomatic operation are manifold. Not only the process guidance, but also the data acquisition and evaluation are performed by the computer. By a remote control the operator is able to find quickly a reflex and to drive the crystal in every desired measuring position. The complete protocollation of all important measuring parameters, the convenient data storage, as well as the automatic evaluation are much useful for the user. Finally the measuring time can be increased to practically 24 hours per day. By this the versed characterization by means of γ-diffractometry is put on a completely new level. (orig.) [de

  11. Present status of neutron beam facilities at the research reactor, HANARO, and its future prospect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang-Hee; Kang, Young-Hwan; Kuk, Il-Hiun [Korea Atomic Energy Research Institute, Taejon (Korea)

    2001-03-01

    Korea has been operating its new research reactor, HANARO, since its first criticality in 1995. It is an open-tank-in-pool type reactor using LEU fuel with thermal neutron flux of 2 x 10{sup 14} nominally at the nose in the D{sub 2}O reflector having 7 horizontal beam ports and a provision of vertical hole for cold neutron source installation. KAERI has pursued an extensive instrument development program since 1992 by the support of the nuclear long-term development program of the government and there are now 4 working instruments. A high resolution powder diffractometer and a neutron radiography facility has been operational since late 1997 and 1996, respectively. A four-circle diffractometer has been fully working since mid 1999 and a small angle neutron spectrometer is just under commissioning phase. With the development of linear position sensitive detector with delay-line readout electronics, we have developed a residual stress instrument as an optional machine to the HRPD for last two years. Around early 1998 informal users program started with friendly users and it became a formal users support program by the ministry of science and technology. Short description for peer group formation and users activities is given. (author)

  12. Present status of neutron beam facilities at the research reactor, HANARO, and its future prospect

    International Nuclear Information System (INIS)

    Lee, Chang-Hee; Kang, Young-Hwan; Kuk, Il-Hiun

    2001-01-01

    Korea has been operating its new research reactor, HANARO, since its first criticality in 1995. It is an open-tank-in-pool type reactor using LEU fuel with thermal neutron flux of 2 x 10 14 nominally at the nose in the D 2 O reflector having 7 horizontal beam ports and a provision of vertical hole for cold neutron source installation. KAERI has pursued an extensive instrument development program since 1992 by the support of the nuclear long-term development program of the government and there are now 4 working instruments. A high resolution powder diffractometer and a neutron radiography facility has been operational since late 1997 and 1996, respectively. A four-circle diffractometer has been fully working since mid 1999 and a small angle neutron spectrometer is just under commissioning phase. With the development of linear position sensitive detector with delay-line readout electronics, we have developed a residual stress instrument as an optional machine to the HRPD for last two years. Around early 1998 informal users program started with friendly users and it became a formal users support program by the ministry of science and technology. Short description for peer group formation and users activities is given. (author)

  13. Applications of RIGAKU Dmax Rapid II micro-X-ray diffractometer in the analysis of archaeological metal objects

    Science.gov (United States)

    Mozgai, Viktória; Szabó, Máté; Bajnóczi, Bernadett; Weiszburg, Tamás G.; Fórizs, István; Mráv, Zsolt; Tóth, Mária

    2017-04-01

    During material analysis of archaeological metal objects, especially their inlays or corrosion products, not only microstructure and chemical composition, but mineralogical composition is necessary to be determined. X-ray powder diffraction (XRD) is a widely-used method to specify the mineralogical composition. However, when sampling is not or limitedly allowed due to e.g. the high value of the object, the conventional XRD analysis can hardly be used. Laboratory micro-XRD instruments provide good alternatives, like the RIGAKU Dmax Rapid II micro-X-ray diffractometer, which is a unique combination of a MicroMax-003 third generation microfocus, sealed tube X-ray generator and a curved 'image plate' detector. With this instrument it is possible to measure as small as 10 µm area in diameter on the object. Here we present case studies for the application of the micro-XRD technique in the study of archaeological metal objects. In the first case niello inlay of a Late Roman silver augur staff was analysed. Due to the high value of the object, since it is the only piece known from the Roman Empire, only non-destructive analyses were allowed. To reconstruct the preparation of the niello, SEM-EDX analysis was performed on the niello inlays to characterise their chemical composition and microstructure. Two types of niello are present: a homogeneous, silver sulphide niello (acanthite) and an inhomogeneous silver-copper sulphide niello (exsolution of acanthite and jalpaite or jalpaite and stromeyerite). The micro-X-ray diffractometer was used to verify the mineralogical composition of the niello, supposed on the base of SEM results. In the second case corrosion products of a Late Roman copper cauldron with uncertain provenance were examined, since they may hold clues about the burial conditions (pH, Eh, etc.) of the object. A layer by layer analysis was performed in cross sections of small metal samples by using electron microprobe and micro-X-ray diffractometer. The results

  14. High-Resolution Powder Diffractometer HRPT for Thermal Neutrons at SINQ

    International Nuclear Information System (INIS)

    Fischer, P.; Koch, M.; Koennecke, M.; Pomjakushin, V.; Schefer, J.; Schlumpf, N.

    1999-01-01

    The new neutron powder diffractometer at the Swiss continuous spallation neutron source SINQ is designed as a flexible instrument for high resolution [best values δd/d: ( -3 with d = lattice spacing in the high resolution or high intensity modes, respectively]. It uses large scattering angles 2Θ M = 120 deg or 90 deg of the monochromator, a 28 cm high, vertically focusing wafer type Ge(hkk) monochromator and a position-sensitive 3 He detector(3.6 bar) produced by Cerca at Romans, France. It has 1600 (25x64) detectors with an angular separation of 0.1 deg and includes modern electronics developed by E. Berruyer, Cerca and PSI. The SICS software of PSI controls the instrument with a server running on an unix workstation and clients written in Java through the TCP/IP network. The design principles and first experiences are presented. The interdisciplinary applications of HRPT will permit high-resolution refinement of chemical and magnetic structures as well as phase analysis including the detection of defects and internal microstrain. In particular real-time investigations of chemical or structural changes and of magnetic phase transitions in crystalline, quasicrystalline, amorphous and liquid samples including technically interesting new materials are possible. (author)

  15. AND/R: Advanced neutron diffractometer/reflectometer for investigation of thin films and multilayers for the life sciences

    International Nuclear Information System (INIS)

    Dura, Joseph A.; Pierce, Donald J.; Majkrzak, Charles F.; Maliszewskyj, Nicholas C.; McGillivray, Duncan J.; Loesche, Mathias; O'Donovan, Kevin V.; Mihailescu, Mihaela; Perez-Salas, Ursula; Worcester, David L.; White, Stephen H.

    2006-01-01

    An elastic neutron scattering instrument, the advanced neutron diffractometer/reflectometer (AND/R), has recently been commissioned at the National Institute of Standards and Technology Center for Neutron Research. The AND/R is the centerpiece of the Cold Neutrons for Biology and Technology partnership, which is dedicated to the structural characterization of thin films and multilayers of biological interest. The instrument is capable of measuring both specular and nonspecular reflectivity, as well as crystalline or semicrystalline diffraction at wave-vector transfers up to approximately 2.20 A -1 . A detailed description of this flexible instrument and its performance characteristics in various operating modes are given

  16. Design of a microcomputer-based X-ray diffractometer controller

    International Nuclear Information System (INIS)

    Naval, P.C. Jr.

    1988-01-01

    This work describes the design of an Apple II-based X-ray diffractometer controller capable of acquiring and analyzing X-ray powder diffraction data. The controller's interrupt-drivers hardware includes an on-based scaler for counting X-ray pulses, a closed-loop stepper motor driver for Philips PW 1050 Vertical Goniometer, and circuits for present data collection and safety. ACQUIRE - data acquisition program for the controller coordinates its various devices so that it can perform sample scanning in any of the following modes: continuous, present tome or present count scanning. This program watches over the scanning process and will try to correct any error it detects. Any fault monitored is logged on disk. The collected diffraction data are stored on disk together with its data acquisition parameters and may be transported to another computer. Data analysis is done by ANALYZE a program that operates on the output file generated by ACQUIRE. Its 15 single-keystroke commands permit panning and zooming of the sample's diffractogram, data smoothing, data peak search, peak report generation, and digital plotting. Data smoothing uses a third-degree Savitzky-Golay Convoluting Filter of user defined width. For peak detection, the peak search algorithm examines the diffractograms second derivative for any Gaussian resemblance and checks the peaks' area for statistical significance. The hard copy plot is available from any on-line digital plotted supporting EPSON's Mode D Plotter Commands. (Author). 15 refs. Appendixes p. 85-163

  17. National facility for neutron beam research

    Indian Academy of Sciences (India)

    The first fully automated computer controlled diffractometer was designed and commissioned ... missioning the spectrometers at the reactor with help from Nuclear Physics Division workshop ... ical extensions of the work carried out at CIRUS.

  18. Surface correlation function analysis of high resolution scattering data from mirrored surfaces obtained using a triple-axis X-ray diffractometer

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    methods is that they are bandwidth-limited. A crucial point in the analysis of data is, therefore, to specify accurately the wavelength bandwidth limitation and to determine the surface autocorrelation function within this bandwidth. The authors present a number of scattering measurements obtained using...... a triple-axis perfect-crystal X-ray diffractometer and the results of an autocorrelation function analysis. Furthermore, they present some measurements of integrated reflectivity, which they believe provide evidence for microroughness in the range from a few angstroms to tens of microns...

  19. Neutron scattering in Indonesia. Country report

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, Abarrul [Neutron Scattering Laboratory, R and D Center for Materials Science and Technology, National Nuclear Energy Agency, Serpong (Indonesia)

    2000-10-01

    Neutron scattering in Indonesia is still alienated due to some reasons and conditions which are discussed. The reactor and its latest operation mode are also described. The neutron beam facilities which include one diffractometer for residual stress measurement, one diffractometer for single crystal structural determination and texture measurement, one high resolution powder diffractometer, one neutron radiography facility, one triple axis spectrometer, one small angle neutron scattering spectrometer and one high resolution small angle neutron scattering spectrometer were presented briefly together with improvements of neutron intensities at some spectrometers in connection with the setting of main beam shutter position. Special attention is given for four instruments mostly related to this workshop. Their performances and problems faced in the past 9 months are presented as well as the future plan for refurbishment and development. (author)

  20. In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Freeland, J. W.; Hong, Hawoong, E-mail: hhong@aps.anl.gov [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Tung, I. C. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Chang, S.-H.; Bhattacharya, A.; Fong, D. D. [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2016-01-15

    In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-ray and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques.

  1. In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy

    International Nuclear Information System (INIS)

    Lee, J. H.; Freeland, J. W.; Hong, Hawoong; Tung, I. C.; Chang, S.-H.; Bhattacharya, A.; Fong, D. D.

    2016-01-01

    In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-ray and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques

  2. Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Jing, Linyuan; Wehner, Gregory J; Suever, Jonathan D; Charnigo, Richard J; Alhadad, Sudad; Stearns, Evan; Mojsejenko, Dimitri; Haggerty, Christopher M; Hickey, Kelsey; Valente, Anne Marie; Geva, Tal; Powell, Andrew J; Fornwalt, Brandon K

    2016-08-22

    Patients with repaired tetralogy of Fallot (rTOF) suffer from progressive ventricular dysfunction decades after their surgical repair. We hypothesized that measures of ventricular strain and dyssynchrony would predict deterioration of ventricular function in patients with rTOF. A database search identified all patients at a single institution with rTOF who underwent cardiovascular magnetic resonance (CMR) at least twice, >6 months apart, without intervening surgical or catheter procedures. Seven primary predictors were derived from the first CMR using a custom feature tracking algorithm: left (LV), right (RV) and inter-ventricular dyssynchrony, LV and RV peak global circumferential strains, and LV and RV peak global longitudinal strains. Three outcomes were defined, whose changes were assessed over time: RV end-diastolic volume, and RV and LV ejection fraction. Multivariate linear mixed models were fit to investigate relationships of outcomes to predictors and ten potential baseline confounders. One hundred fifty-three patients with rTOF (23 ± 14 years, 50 % male) were included. The mean follow-up duration between the first and last CMR was 2.9 ± 1.3 years. After adjustment for confounders, none of the 7 primary predictors were significantly associated with change over time in the 3 outcome variables. Only 1-17 % of the variability in the change over time in the outcome variables was explained by the baseline predictors and potential confounders. In patients with repaired tetralogy of Fallot, ventricular dyssynchrony and global strain derived from cine CMR were not significantly related to changes in ventricular size and function over time. The ability to predict deterioration in ventricular function in patients with rTOF using current methods is limited.

  3. J-PARC and the prospective neutron sciences

    International Nuclear Information System (INIS)

    Masatoshi Arai

    2009-01-01

    Full text: J-PARC is an interdisciplinary facility with high power proton accelerator complex containing particle physics, nuclear physics, muon science and neutron science facilities. After 8 years construction, she is almost ready to open for users. Materials-Life Science Facility (MLF) of J-PARC is composed from very intensive pulsed neutron and muon facilities at 1 MW of the accelerated proton power. The neutron peak flux will be as high as several hundred times of existing high flux reactors. Therefore, it is highly expected that new sciences will be explored by J-PARC, MLF. The first neutrons was already produced in the last May. The MLF facility has 23 neutron beam ports. About 12 instruments are under commissioning or construction. Out of four instruments are already opened for users since December, 2008.. In the commissioning High Resolution Powder Diffractometer showed the world highest resolution d/d=0.04% as was designed. Other instruments, high intensity powder diffractometer, protein crystal diffractometer, residual stress analysis diffractometer, high intensity chopper spectrometer, confirmed expected intensity and spectrum from neutron beam line. By the end of March, a cold neutron chopper spectrometer will also come on line. Those instruments are taking advantages with optical devices for neutron transport to realize very high flux at sample position. By taking high performances of neutron moderators of MLF, the instruments will realize the world class resolution and high intensity. Ranging from Bio-science, material science, engineering, industrial use of neutrons to fundamental physics, we are exciting to see cutting-edge sciences with great anticipation to be produced from J-PARC, MLF. (author)

  4. Assessment of early diastolic intraventricular pressure gradient in the left ventricle among patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Kobayashi, Maki; Takahashi, Ken; Yamada, Mariko; Yazaki, Kana; Matsui, Kotoko; Tanaka, Noboru; Shigemitsu, Sachie; Akimoto, Katsumi; Kishiro, Masahiko; Nakanishi, Keisuke; Kawasaki, Shiori; Nii, Masaki; Itatani, Keiichi; Shimizu, Toshiaki

    2017-11-01

    Assessment of left ventricular (LV) dysfunction is vital in patients with repaired tetralogy of Fallot (rTOF). The early diastolic intraventricular pressure gradient (IVPG) in the LV plays an important role in diastolic function. IVPG is calculated as the intraventricular pressure difference divided by the LV length, which allows to account for differences in LV size and therefore calculate IVPG in children. We aimed to investigate the mechanisms of LV diastolic dysfunction by measuring mid-to-apical IVPG as an indicator of the active suction force sucking blood from the left atrium into the LV. We included 38 rTOF patients and 101 healthy controls. The study population was stratified based on age group into children (4-9 years), adolescents (10-15 years), and adults (16-40 years). IVPGs were calculated based on mitral inflow measurements obtained using color M-mode Doppler echocardiography. Although total IVPGs did not differ between rTOF patients and controls, mid-to-apical IVPGs in adolescents and adults were smaller among rTOF patients than among controls (0.15 ± 0.05 vs. 0.21 ± 0.06 mmHg/cm, p < 0.05; 0.09 ± 0.07 vs. 0.17 ± 0.05 mmHg/cm, p < 0.001; respectively). Additionally, only mid-to-apical IVPG correlated linearly with peak circumferential strain (ρ = 0.217, p = 0.011), longitudinal strain (ρ = -0.231, p = 0.006), torsion (ρ = -0.200, p = 0.018), and untwisting rate in early diastole (ρ = -0.233, p = 0.006). In rTOF, the mechanisms underlying diastolic dysfunction involve reduced active suction force, which correlates with reduced LV deformation in all directions.

  5. New POLDI - project of reincarnation of a polarized neutron diffractometer at the reactor PIK

    Science.gov (United States)

    Zobkalo, I.; Gavrilov, S.; Matveev, V.; Fenske, J.

    2017-06-01

    The project of a considerable modernization of the polarized neutron diffractometer POLDI is discussed. It assumes the adoption of POLDI to a broader range of magnetic investigations such as determination of magnetic structures, detailed investigation of complex magnetic structures, studies of magnetic domains, study of the magnetization density maps, magnetic form-factor particularities, local susceptibility, etc. The flexible construction should permit to use either spherical neutron polarimetry technique or flipping ratio technique. Different types of polarization system were analyzed. Original focusing fan-like bender is proposed as polarizer unit. Our simulations give evidence that for the wavelength range 1.3 - 3 Å and with suitable size, such a device can give much better efficiency than 3He cells, which are often in use. The higher flux at the sample position of a factor of at least 3.3, with lower divergence and good polarization degree from 98% (1.3 Å) to above 94% (3 Å) makes the bender set-up favorable over the layout with a 3He-cell.

  6. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hirtler, Daniel [University Hospital Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology (Heart Center, University of Freiburg), Freiburg (Germany); Garcia, Julio; Barker, Alex J. [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Geiger, Julia [University Childrens' Hospital Zurich, Department of Radiology, Zurich (Switzerland)

    2016-10-15

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  7. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    International Nuclear Information System (INIS)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J.; Geiger, Julia

    2016-01-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  8. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI.

    Science.gov (United States)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J; Geiger, Julia

    2016-10-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p tetralogy of Fallot. • Regurgitant flow in the main pulmonary artery is associated with higher right heart vorticity.

  9. Structural characterization of advanced ceramics using the neutron diffractometer developed by Instituto de Pesquisas Energeticas e Nucleares (IPEN)

    International Nuclear Information System (INIS)

    Parente, C.B.R.; Mazzocchi, V.L.

    1999-01-01

    Application of neutron diffractometer at the Instituto de Pesquisas Energeticas Nucleares, Sao Paulo, Brazil, in the structural investigations of advanced ceramics was presented. Methodology of the analysis of neutron diffraction patterns was tested with BaLiF 3 single crystals and also doped with Ni 2+ or Pb 2+ ions. The same methodology was used to investigate the HTSC phases in the system Bi-Sr-Ca-Cu-O. The system Bi 1.7 Pb 0.3 Sr 2 Ca 2.2 Cu 3.5 O 10.6 was also investigated. Addition of Pb 2+ ions increased the fraction of high-T c phase 2223. Symmetry in neutron multiple diffraction patterns, obtained for aluminium single crystal, was elaborated. Crystal lattice parameter for aluminium single crystal was determined at different temperatures using neutron multiple diffraction. (author)

  10. An electrochemical cell for in operando studies of lithium/sodium batteries using a conventional x-ray powder diffractometer

    DEFF Research Database (Denmark)

    Shen, Yanbin; Pedersen, Erik Ejler; Christensen, Mogens

    2014-01-01

    An electrochemical cell has been designed for powder X-ray diffraction (PXRD) studies of lithium ion batteries (LIB) and sodium ion batteries (SIB) in operando with high time resolution using conventional powder X-ray diffractometer. The cell allows for studies of both anode and cathode electrode...... to operate and maintain. Test examples on lithium insertion/extraction in two spinel-type LIB electrode materials (Li4Ti5O12 anode and LiMn2O4 cathode) are presented as well as first results on sodium extraction from a layered SIB cathode material (Na0.84Fe0.56Mn0.44O2)....

  11. Improved sample manipulation at the STRESS-SPEC neutron diffractometer using an industrial 6-axis robot for texture and strain analyses

    Energy Technology Data Exchange (ETDEWEB)

    Randau, C. [Institute for Materials Science and Engineering, Clausthal University of Technology, D-38678 Clausthal-Zellerfeld (Germany); Brokmeier, H.G., E-mail: heinz-guenter.brokmeier@tu-clausthal.de [Institute for Materials Science and Engineering, Clausthal University of Technology, D-38678 Clausthal-Zellerfeld (Germany); Institute of Materials Research, Helmholtz-Centre Geesthacht, D-21502 Geesthacht (Germany); Gan, W.M. [Institute of Materials Research, Helmholtz-Centre Geesthacht, D-21502 Geesthacht (Germany); Hofmann, M.; Voeller, M. [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II), TU München, D-85747 Garching (Germany); Tekouo, W. [Institute for Machine Tools and Industrial Management, TU München, D-85747 Garching (Germany); Al-hamdany, N. [Institute for Materials Science and Engineering, Clausthal University of Technology, D-38678 Clausthal-Zellerfeld (Germany); Seidl, G. [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II), TU München, D-85747 Garching (Germany); Schreyer, A. [Institute of Materials Research, Helmholtz-Centre Geesthacht, D-21502 Geesthacht (Germany)

    2015-09-11

    The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC.

  12. Improved sample manipulation at the STRESS-SPEC neutron diffractometer using an industrial 6-axis robot for texture and strain analyses

    International Nuclear Information System (INIS)

    Randau, C.; Brokmeier, H.G.; Gan, W.M.; Hofmann, M.; Voeller, M.; Tekouo, W.; Al-hamdany, N.; Seidl, G.; Schreyer, A.

    2015-01-01

    The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC

  13. Mechanisms of Left Ventricular Dysfunction Assessed by Layer-Specific Strain Analysis in Patients With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yamada, Mariko; Takahashi, Ken; Kobayashi, Maki; Yazaki, Kana; Takayasu, Hirobumi; Akimoto, Katsumi; Kishiro, Masahiko; Inage, Akio; Yoshikawa, Tadahiro; Park, In-Sam; Nakanishi, Keisuke; Kawasaki, Shiori; Shimizu, Toshiaki

    2017-05-25

    Left ventricular (LV) dysfunction in patients with repaired tetralogy of Fallot (rTOF) is an important risk factor for adverse outcomes. The aim of this study was to assess the details and time course of such LV dysfunction using layer-specific strain analysis by echocardiography.Methods and Results:The 66 patients with rTOF (mean age, 16.3±9.3 years) were divided into 3 groups (T1: 4-10 years, T2: 11-20 years, T3: 21-43 years), and 113 controls of similar age (mean age, 17.2±9.3 years) were divided into 3 corresponding groups (C1, C2, and C3). Layer-specific longitudinal strain (LS) and circumferential strain (CS) of 3 myocardial layers (endocardial, midmyocardial, and epicardial) were determined by echocardiography. Basal and papillary endocardial CS values were decreased in T1 compared with C1. With the exception of papillary epicardial CS, basal/papillary CS and LS of all 3 layers decreased in T2 compared with C2. Excepting papillary epicardial CS, all other values were decreased in T3 compared with C3. Potential myocardial damage was found in the endocardium at the basal and papillary levels of the LV in young patients with rTOF, extending from the endocardium to the epicardium and from the base to the apex. This is the possible time course of LV dysfunction in patients with rTOF.

  14. A polarised SUSANS facility to study magnetic systems

    Indian Academy of Sciences (India)

    The experiment was carried out at the V12b double crystal diffractometer set ... upper pole piece and just below the lower pole piece, within a magnet-grade soft iron 'C'. ... about 3 µm with the up- and 9 µm with the down-spin neutrons.

  15. Performance of a carbon nanotube field emission electron gun

    Science.gov (United States)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  16. The small angle diffractometer SANS at PSI

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, W [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    With the start-up of SINQ an instrument for small angle neutron scattering will be operational which compares well with the world`s largest and most powerful facilities of this kind. Following the classical principle of the D11-instrument of ILL, it is equipped with state-of-the-art components as are nowadays available, including options for further upgrading. Great emphasis was laid upon providing a flexible, universal multi-user facility which guarantees a comfortable and reliable operation. In the present paper, the principle layout of the instrument is presented, and the individual components are described in detail. The paper concludes with model application of small angle scattering to a system of dilute CuCo alloys which undergo a phase separation under thermal treatment, forming spherical Co-precipitates dispersed in a Cu-rich matrix. (author) 3 figs., 1 tab., 14 refs.

  17. Solutions for implementing time-of-flight techniques in low-angle neutron scattering, as realized on the Low-Q Diffractometer at Los Alamos

    International Nuclear Information System (INIS)

    Hjelm, R.P. Jr.; Seeger, P.A.

    1992-01-01

    The implementation of small-angle (Low-momentum transfer) neutron scattering at pulsed spallation sources, using time of flight methods, has meant the introduction of some new ideas in instrument design, data acquisition, data reduction and computer management of the experiment and the data. Here we recount some of the salient aspects of solutions for implementing time of fight small-angle neutron scattering instruments at pulsed sources, as realized on the Low-Q Diffractometer, LQD, at Los Alamos. We consider, fortlier, some of the problems that are yet to be solved, and take a short excursion into the future of SANS instrumentation at pulsed sources

  18. Position controller for the arm of a neutron diffractometer using fuzzy logic

    International Nuclear Information System (INIS)

    Ayala P, G.F.

    1994-01-01

    The neutron diffractometer is an important instrument coupled to one of the radial outlets of the TRIGA-3-Salazar Reactor and is used mainly to analyze textures and crystal lattices. One of its main components is the velocity analysis goniometer which controls in a tangential way the movements of the sensor requiring for this a resolution of a hundredth of degree, but at the same time wide displacements are required. It is necessary to design and construct a system on the basis of a micro controller which control the long movements in a rapid way and with the needed accuracy. In this work, a proposition is presented: to replace the A.C. motor with a D.C. motor with a wide range of velocity and supplied with a card (DAC) to control the velocity by means of digital data. Moreover, a programmed micro controller with an algorithm based on fuzzy logic receiving data in BCD will be use. The use of micro controller will allow to set free the personal computer of the position of the goniometer; nevertheless, the system will report to the P C and its control program about the present position of the goniometer and the time when the desired position is reached. It is also consider that the user will be away from the system (a minimum of 15 meters) in order to avoid the zone with a high intensity of background radiation. (Author)

  19. A new method of Debye-Scherrer pattern integration on two-dimensional detectors, demonstrated for the new structure powder diffractometer (SPODI) at the FRM-II in Garching

    CERN Document Server

    Elf, F; Artus, G R J; Roth, S

    2002-01-01

    The expected diffraction patterns of the new powder diffractometer SPODI, currently under construction at the FRM-II in Garching, will be smeared Debye-Scherrer rings as depicted by Monte Carlo (MC) simulations. To overcome this disadvantage, a concept based on the combination of MC simulations and empirical approximation methods is developed to reverse the smearing by deconvolution and then summing up along the rings, including corrections for different arc lengths, resulting in conventional one-dimensional diffraction patterns suitable for Rietveld-refinement programs without further processing. (orig.)

  20. Neutron Powder Diffraction Measurements of the Spinel MgGa2O4:Cr3+ - A Comparative Study between the High Flux Diffractometer D2B at the ILL and the High Resolution Powder Diffractometer Aurora at IPEN

    International Nuclear Information System (INIS)

    Da Silva, M A F M; Sosman, L P; Yokaichiya, F; Henry, P F; Bordallo, H N; Mazzocchi, V L; Parente, C B R; Mestnik-Filho, J

    2012-01-01

    Optical materials that emit from the visible to the near-infrared spectral region are of great interest due to their possible application as tunable radiation sources, as signal transmission, display, optoelectronics signal storage, cellulose industry as well as in dosimetry. One important family of such systems are the spinel compounds doped with Cr 3+ , in which the physical the properties are related to the insertion of punctual defects in the crystalline structure. The purpose of our work is two fold. First, we compare the luminescence of the MgGa 2 O 4 -Ga 2 O 3 system with the single phase Ga 2 O 3 and MgGa 2 O 4 and relate structural changes observed in MgGa 2 O 4 -Ga 2 O 3 system to the optical properties, and secondly, to compare the neutron powder diffraction results obtained using two diffractometers: D2B located at the ILL (Grenoble, France) and Aurora located at IPEN (São Paulo, Brazil). In the configuration chosen, Aurora shows an improved resolution, which is related to the design of its silicon focusing monochromator.

  1. A horizontal two-axis diffractometer for high-energy X-ray diffraction using synchrotron radiation on bending magnet beamline BL04B2 at SPring-8

    CERN Document Server

    Kohara, S; Kashihara, Y; Matsumoto, N; Umesaki, N; Sakai, I

    2001-01-01

    A horizontal two-axis diffractometer for glasses and liquids, installed at SPring-8 bending magnet beamline BL04B2, operated at 8 GeV electron energy, is described. Photon energies of 37.8 and 61.7 keV were obtained using a bent Si (1 1 1) crystal and a bent Si (2 2 0) crystal, respectively. The instrument has been successfully applied to measure diffraction spectra of vitreous SiO sub 2 in transmission geometry up to scattering vector Q=36 A sup - sup 1 , and measured total structure factor S(Q) was well reproduced by reverse Monte Carlo modelling.

  2. A horizontal two-axis diffractometer for high-energy X-ray diffraction using synchrotron radiation on bending magnet beamline BL04B2 at SPring-8

    International Nuclear Information System (INIS)

    Kohara, Shinji; Suzuya, Kentaro; Kashihara, Yasuharu; Matsumoto, Norimasa; Umesaki, Norimasa; Sakai, Ichiro

    2001-01-01

    A horizontal two-axis diffractometer for glasses and liquids, installed at SPring-8 bending magnet beamline BL04B2, operated at 8 GeV electron energy, is described. Photon energies of 37.8 and 61.7 keV were obtained using a bent Si (1 1 1) crystal and a bent Si (2 2 0) crystal, respectively. The instrument has been successfully applied to measure diffraction spectra of vitreous SiO 2 in transmission geometry up to scattering vector Q=36 A -1 , and measured total structure factor S(Q) was well reproduced by reverse Monte Carlo modelling

  3. Laboratory and In-Flight In-Situ X-ray Imaging and Scattering Facility for Materials, Biotechnology and Life Sciences

    Science.gov (United States)

    2003-01-01

    We propose a multifunctional X-ray facility for the Materials, Biotechnology and Life Sciences Programs to visualize formation and behavior dynamics of materials, biomaterials, and living organisms, tissues and cells. The facility will combine X-ray topography, phase micro-imaging and scattering capabilities with sample units installed on the goniometer. This should allow, for the first time, to monitor under well defined conditions, in situ, in real time: creation of imperfections during growth of semiconductors, metal, dielectric and biomacromolecular crystals and films, high-precision diffraction from crystals within a wide range of temperatures and vapor, melt, solution conditions, internal morphology and changes in living organisms, tissues and cells, diffraction on biominerals, nanotubes and particles, radiation damage, also under controlled formation/life conditions. The system will include an ultrabright X-ray source, X-ray mirror, monochromator, image-recording unit, detectors, and multipurpose diffractometer that fully accommodate and integrate furnaces and samples with other experimental environments. The easily adjustable laboratory and flight versions will allow monitoring processes under terrestrial and microgravity conditions. The flight version can be made available using a microsource combined with multilayer or capillary optics.

  4. A possibility of parallel and anti-parallel diffraction measurements on neu- tron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition

    Science.gov (United States)

    Choi, Yong Nam; Kim, Shin Ae; Kim, Sung Kyu; Kim, Sung Baek; Lee, Chang-Hee; Mikula, Pavel

    2004-07-01

    In a conventional diffractometer having single monochromator, only one position, parallel position, is used for the diffraction experiment (i.e. detection) because the resolution property of the other one, anti-parallel position, is very poor. However, a bent perfect crystal (BPC) monochromator at monochromatic focusing condition can provide a quite flat and equal resolution property at both parallel and anti-parallel positions and thus one can have a chance to use both sides for the diffraction experiment. From the data of the FWHM and the Delta d/d measured on three diffraction geometries (symmetric, asymmetric compression and asymmetric expansion), we can conclude that the simultaneous diffraction measurement in both parallel and anti-parallel positions can be achieved.

  5. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Benafan, O., E-mail: othmane.benafan@nasa.gov [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States); Padula, S. A. [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Skorpenske, H. D.; An, K. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Vaidyanathan, R. [Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States)

    2014-10-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel{sup ®} 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N·m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ~1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

  6. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer

    International Nuclear Information System (INIS)

    Benafan, O.; Padula, S. A.; Skorpenske, H. D.; An, K.; Vaidyanathan, R.

    2014-01-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel ® 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N·m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ∼1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes

  7. New hardware and software platform for experiments on a HUBER-5042 X-ray diffractometer with a DISPLEX DE-202 helium cryostat in the temperature range of 20-300 K

    Science.gov (United States)

    Dudka, A. P.; Antipin, A. M.; Verin, I. A.

    2017-09-01

    Huber-5042 diffractometer with a closed-cycle Displex DE-202 helium cryostat is a unique scientific instrument for carrying out X-ray diffraction experiments when studying the single crystal structure in the temperature range of 20-300 K. To make the service life longer and develop new experimental techniques, the diffractometer control is transferred to a new hardware and software platform. To this end, a modern computer; a new detector reader unit; and new control interfaces for stepper motors, temperature controller, and cryostat vacuum pumping system are used. The system for cooling the X-ray tube, the high-voltage generator, and the helium compressor and pump for maintaining the desired vacuum in the cryostat are replaced. The system for controlling the primary beam shutter is upgraded. A biological shielding is installed. The new program tools, which use the Linux Ubuntu operating system and SPEC constructor, include a set of drivers for control units through the aforementioned interfaces. A program for searching reflections from a sample using fast continuous scanning and a priori information about crystal is written. Thus, the software package for carrying out the complete cycle of precise diffraction experiment (from determining the crystal unit cell to calculating the integral reflection intensities) is upgraded. High quality of the experimental data obtained on this equipment is confirmed in a number of studies in the temperature range from 20 to 300 K.

  8. Neutron beam instruments at Harwell

    International Nuclear Information System (INIS)

    Baston, A.H.; Harris, D.H.C.

    1978-11-01

    A list and brief descriptions are given of the neutron beam facilities for U.K. scientists at Harwell and in academic institutions, available under an agreement between the Science Research Council and AERE (Harwell). The list falls under the following headings: reactor instruments (single crystal diffractometers, powder diffractometers, triple axis spectrometers, time-of-flight cold neutron twin rotor spectrometer, beryllium filter spectrometer, MARX spectrometer, Harwell small-angle scattering spectrometer); LINAC instruments (total scattering spectrometer, back scattering spectrometer, active sample spectrometer, inelastic rotor spectrometer, constant Q spectrometer); ancillary equipment (cryostats, superconducting magnets, electromagnets, furnaces). (U.K.)

  9. Pulsed Neutron Powder Diffraction for Materials Science

    Science.gov (United States)

    Kamiyama, T.

    2008-03-01

    The accelerator-based neutron diffraction began in the end of 60's at Tohoku University which was succeeded by the four spallation neutron facilities with proton accelerators at the High Energy Accelerator Research Organization (Japan), Argonne National Laboratory and Los Alamos Laboratory (USA), and Rutherford Appleton Laboratory (UK). Since then, the next generation source has been pursued for 20 years, and 1MW-class spallation neutron sources will be appeared in about three years at the three parts of the world: Japan, UK and USA. The joint proton accelerator project (J-PARC), a collaborative project between KEK and JAEA, is one of them. The aim of the talk is to describe about J-PARC and the neutron diffractometers being installed at the materials and life science facility of J-PARC. The materials and life science facility of J-PARC has 23 neutron beam ports and will start delivering the first neutron beam of 25 Hz from 2008 May. Until now, more than 20 proposals have been reviewed by the review committee, and accepted proposal groups have started to get fund. Those proposals include five polycrystalline diffractometers: a super high resolution powder diffractometer (SHRPD), a 0.2%-resolution powder diffractometer of Ibaraki prefecture (IPD), an engineering diffractometers (Takumi), a high intensity S(Q) diffractometer (VSD), and a high-pressure dedicated diffractometer. SHRPD, Takumi and IPD are being designed and constructed by the joint team of KEK, JAEA and Ibaraki University, whose member are originally from the KEK powder group. These three instruments are expected to start in 2008. VSD is a super high intensity diffractometer with the highest resolution of Δd/d = 0.3%. VSD can measure rapid time-dependent phenomena of crystalline materials as well as glass, liquid and amorphous materials. The pair distribution function will be routinely obtained by the Fourier transiformation of S(Q) data. Q range of VSD will be as wide as 0.01 Å-1stress mapping inside

  10. Paul Scherrer Institut annual report 1995. Annex IIIA: Solid state research at large facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baltensperger, U.; Lorenzen, R. [eds.

    1996-10-01

    The PSI research department IIIA is engaged in the final push to establish two research facilities: - the spallation neutron source (SINQ) and its instrumentation, - a positron source with high beam quality. The latter is essentially completed and ready for commissioning. The laboratory for Ion Beam Physics again served to many institutions with their accelerator mass spectroscopy by analyzing about 4000 samples. The new gas-jet facility and the neutron activation system at SINQ will be most important for the work of the laboratory of Radio- and Environmental Chemistry. Hence considerable effort has been put into the conception of this insertion device at the spallation source. Like in the previous year the laboratory of Neutron scattering was still relying on the access to neutron sources elsewhere than PSI. Regular access was available at ILL at a powder diffractometer and a triple axis spectrometer, upgraded and operated by PSI. Hence, besides the work for the instrumentation of SINQ, we had the opportunity to keep the scientific activities alive. Results of the laboratory of Astrophysics: one of the Radiation Environmental Monitors (REM) has now been in orbit for more than one year aboard the UK-satellite STRV-1B. The other monitor on a low circular orbit of a MIR-station also reports its results since about one year. (author) figs., tabs., refs.

  11. Paul Scherrer Institut annual report 1995. Annex IIIA: Solid state research at large facilities

    International Nuclear Information System (INIS)

    Baltensperger, U.; Lorenzen, R.

    1996-01-01

    The PSI research department IIIA is engaged in the final push to establish two research facilities: - the spallation neutron source (SINQ) and its instrumentation, - a positron source with high beam quality. The latter is essentially completed and ready for commissioning. The laboratory for Ion Beam Physics again served to many institutions with their accelerator mass spectroscopy by analyzing about 4000 samples. The new gas-jet facility and the neutron activation system at SINQ will be most important for the work of the laboratory of Radio- and Environmental Chemistry. Hence considerable effort has been put into the conception of this insertion device at the spallation source. Like in the previous year the laboratory of Neutron scattering was still relying on the access to neutron sources elsewhere than PSI. Regular access was available at ILL at a powder diffractometer and a triple axis spectrometer, upgraded and operated by PSI. Hence, besides the work for the instrumentation of SINQ, we had the opportunity to keep the scientific activities alive. Results of the laboratory of Astrophysics: one of the Radiation Environmental Monitors (REM) has now been in orbit for more than one year aboard the UK-satellite STRV-1B. The other monitor on a low circular orbit of a MIR-station also reports its results since about one year. (author) figs., tabs., refs

  12. Estimation of residual stress in cold rolled iron-disks from strain measurements on the high resolution Fourier diffractometer

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Balagurov, A.M.; Taran, Yu.V.

    1995-01-01

    The results of estimating residual stresses in cold rolled iron disks by measurements with the high resolution Fourier diffractometer (HRFD) at the IBR-2 pulsed reactor are presented. These measurements were made for calibration of magnetic and ultrasonic measurements carried out at the Fraunhofer-Institute for Nondestructive Testing in Saarbrucken (Germany). The tested objects were cold rolled steel disks of 2.5 mm thickness and diameter of about 500 mm used for forming small, gas pressure tanks. Neutron diffraction experiments were carried out at the scattering angle 2θ=+152 d eg with resolution Δd/d=1.5·10 -3 . The gauge volume was chosen according to the magnetic measurements lateral resolution 20x20 mm 2 . In the nearest future the neutron diffraction measurements with cold rolled iron disks at the scattering angle 2θ=±90 0 are planned. Also the texture analysis will be included in the Rietveld refinement procedure for more correct calculation of residual stress fields in the cold rolled materials. 8 refs., 10 figs., 1 tab

  13. Clinical course of tricuspid regurgitation in repaired tetralogy of Fallot.

    Science.gov (United States)

    Woudstra, O I; Bokma, J P; Winter, M M; Kiès, P; Jongbloed, M R M; Vliegen, H W; Groenink, M; Meijboom, F J; Mulder, B J M; Bouma, B J

    2017-09-15

    Little is known on the clinical course of tricuspid regurgitation (TR) in patients with repaired tetralogy of Fallot (rTOF) and which patients are at particular risk. This study aims to determine TR course, characteristics associated with TR progression, and the prognostic relevance of TR in rTOF patients. In this dualcenter cohort study, rTOF patients from a prospective national registry with ≥1 cardiac magnetic resonance imaging study and ≥2 echocardiograms available were included. Clinical and imaging data were collected. Cox hazards regression analysis was used to assess patient characteristics associated with progression to severe TR and whether severe TR was associated with the combined clinical endpoint of tachyarrhythmia, heart failure, and death, as time-dependent factor. A total of 216 patients were included (57% men, age 34±12years); 11 patients (5%) had severe TR at baseline. During 7.6±3.5years of follow-up, progression to severe TR occurred in 15 patients (7%). NYHA class ≥2 (HR 5.38, 95%-C.I. 1.91-15.16, p=0.001) and moderate baseline TR (HR 13.10, 95%-C.I. 2.95-58.21, p=0.001) were independently associated with progression to severe TR. Adverse events occurred in 47 patients (22%). The occurrence of severe TR was independently associated with adverse events (HR 3.48, 95%-C.I. 1.68-7.21, p=0.001). In this study, severe TR was present in 12% of adult rTOF patients during 7.6years, and progression to severe TR was most likely in symptomatic patients with moderate baseline TR. In these patients, close surveillance is warranted, because the occurrence of severe TR was associated with worse prognosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Neutron beam applications - Development of single crystal structure analysis technique using the HANARO neutron four circle diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Il Hwan; Kim, Moon Jib; Kim, Jin Gyu [Chungnam National University, Taejon (Korea)

    2000-04-01

    As the four circle diffractometer (FCD) has been set up in HANARO, it has become possible to study the single crystal structures by means of the neutron diffraction. Taking account of the geometry of the FCD, a program for the control of te FCD and neutron data acquisition operating under Windows' circumstance has been accomplished. Also, a computer program which can automatically measure the diffraction intensity data has been developed. All data obtained from the FCD are processed automatically for further work and a software for the single crystal structure analyses has been prepared. A KC1 single crystal was selected as first test sample for a structure analysis had been successfully performed on the FCD using in-house developed program and accordingly their functionings with precision were confirmed. For regular single crystal diffraction experiments, the structure analyses of chrysoberyl and Zr(Y)0{sub 1.87} single crystals were performed using both neutron and X-ray diffraction methods, and the result showed that the neutron diffraction work is superior to the X-ray one from the viewpoint of certain crystallographic information obtainable only from the former one. 24 refs., 15 figs., 15 tabs. (Author)

  15. The use of contrast variation in small angle neutron scattering on the low-Q diffractometer at the Manuel Lujuan Jr. Neutron Scattering Center at Los Alamos National Laboratory (LANSCE)

    International Nuclear Information System (INIS)

    Spaccavento, J.

    1993-01-01

    As a Department of Energy Teacher Research Associate at Los Alamos National Laboratory this past summer, the author was given the opportunity to exit the class-room and enter the world of intense scientific research for an eight week period. In this paper the author briefly describes the Manual Lujan Jr. Neutron Scattering Center at Los Alamos, then focuses specifically on the Low-Q Diffractometer which was the instrument he worked on. The author details one specific experimental technique namely open-quotes Contrast Variation,close quotes and closes by briefly presenting several other interesting applications of neutron scattering

  16. Determination of the zero in the Two theta angle and the wavelength in the neutron diffractometer for the Cyber computer of the ININ and for the IBM compatible microcomputers; Determinacion del cero en el angulo Dos teta y la longitud de onda en el difractometro de neutrones para la computadora Cyber del ININ y para microcomputadoras compatibles con IBM

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L R

    1991-05-15

    The objective of this work consists on determining the calibration in the angular parameters and the neutron wavelength used in the neutron diffractometer of the TRIGA Mark III reactor, through some readings in that a well-known sample is used by means of a Fortran computer program that is used in the CYBER computer of the ININ in Mexico, and/or in micro computers compatible with IBM. The program was also designed to determine the zero of the 2 {theta} angle of the goniometer of the diffractometer. The generated data were proven by means of well-known data of the Powder Diffraction File of the Joint Committee on Powder Diffraction Standards (JCPDS). (Author)

  17. Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Mauro, N. A., E-mail: namauro@noctrl.edu [Department of Physics, North Central College, Naperville, Illinois 60540 (United States); Vogt, A. J. [Instrument and Source Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Derendorf, K. S. [Mechanical Engineering and Materials Science, Washington University, St. Louis, Missouri 63130 (United States); Johnson, M. L.; Kelton, K. F. [Department of Physics and Institute of Materials Science and Engineering, Washington University, 1 Brookings Drive, St. Louis, Missouri 63130 (United States); Rustan, G. E.; Quirinale, D. G.; Goldman, A. I. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Kreyssig, A. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Division of Materials Sciences and Engineering, Ames Laboratory, Ames, Iowa 50011 (United States); Lokshin, K. A. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States); Quantum Condensed Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Neuefeind, J. C.; An, Ke [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Wang, Xun-Li [Department of Physics and Materials Science, City University of Hong Kong, 83 Tat Chee Ave., Kowloon (Hong Kong); Egami, T. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States); Department of Physics and Astronomy, Joint Institute for Neutron Sciences, University of Tennessee, Knoxville, Tennessee 37996 (United States)

    2016-01-15

    Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

  18. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    ... development laboratory are located at APSARA reactor. All the instruments including the detectors and electronics have been developed within BARC. A new powder diffractometer (PD-3) is being developed by UGC-DAE-CSR. The national facility is utilized in collaboration with various universities and other institutions.

  19. Facile synthesis of luminescent and amorphous La2O3-ZrO2:Eu3+ nanofibrous membranes with robust softness

    Science.gov (United States)

    Han, Weidong; Ding, Bin; Park, Mira; Cui, Fuhai; Ghouri, Zafar Khan; Saud, Prem Singh; Kim, Hak-Yong

    2015-08-01

    Novel luminescent and amorphous La2O3-ZrO2:Eu3+ (LZE) nanofibrous membranes with robust softness are fabricated for the first time via a facile electrospinning technique. By incorporating zirconium oxide, the as-prepared lanthanum oxide nanofibrous membranes can be dramatically changed from extreme fragility to robust softness. Meanwhile, the softness and luminescent performance of LZE nanofibrous membranes can be finely controlled by regulating the doping concentration of zirconium oxide and europium in lanthanum oxide nanofibers. Additionally, the crystal structure analysis using X-ray diffractometer and high resolution transmission electron microscopy measurements have confirmed the correlation between the amorphous structure and softness. Furthermore, LZE membranes show the characteristic emission of Eu3+ corresponding to 5D0, 1, 2-7F0, 1, 2, 3, 4 transitions due to an efficient energy transfer from O2- to Eu3+. The LZE nanofibrous membranes with the optimum doping Eu3+ concentration of 3 mol% exhibit excellent softness and luminescent properties, which make the materials to have potential applications in fluorescent lamps and field emission displays.Novel luminescent and amorphous La2O3-ZrO2:Eu3+ (LZE) nanofibrous membranes with robust softness are fabricated for the first time via a facile electrospinning technique. By incorporating zirconium oxide, the as-prepared lanthanum oxide nanofibrous membranes can be dramatically changed from extreme fragility to robust softness. Meanwhile, the softness and luminescent performance of LZE nanofibrous membranes can be finely controlled by regulating the doping concentration of zirconium oxide and europium in lanthanum oxide nanofibers. Additionally, the crystal structure analysis using X-ray diffractometer and high resolution transmission electron microscopy measurements have confirmed the correlation between the amorphous structure and softness. Furthermore, LZE membranes show the characteristic emission of Eu3

  20. The Role of Cardiopulmonary Exercise Testing for Decision Making in Patients with Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Dallaire, Frederic; Wald, Rachel M; Marelli, Ariane

    2017-08-01

    Tetralogy of Fallot is the most common form of cyanotic congenital heart disease. As a result of the surgical strategies employed at the time of initial repair, chronic pulmonary regurgitation (PR) is prevalent in this population. Despite sustained research efforts, patient selection and timing of pulmonary valve replacement (PVR) to address PR in young asymptomatic patients with repaired tetralogy of Fallot (rToF) remain a fundamental but as yet unanswered question in the field of congenital heart disease. The ability of the heart to compensate for the chronic volume overload imposed by PR is critical in the evaluation of the risks and benefits of PVR. The difficulty in clarifying the functional impact of PR on the cardiovascular capacity may be in part responsible for the uncertainty surrounding the timing of PVR. Cardiopulmonary exercise testing (CPET) may be used to assess abnormal cardiovascular response to increased physiologic demands. However, its use as a tool for risk stratification in asymptomatic adolescents and young adults with rToF is still ill-defined. In this paper, we review the role of CPET as a potentially valuable adjunct to current risk stratification strategies with a focus on asymptomatic rToF adolescents and young adults being considered for PVR. The role of maximal and submaximal exercise measurements to identify young patients with a decreased or borderline low peak VO 2 resulting from impaired ventricular function is explored. Current knowledge gaps and research perspectives are highlighted.

  1. Upgrade of detectors of neutron instruments at Neutron Physics Laboratory in Řež

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko, E.I., E-mail: litvin@nf.jinr.ru [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 14980 Dubna (Russian Federation); Ryukhtin, V. [Nuclear Physics Institute of the CAS v.v.i., Řež 130, 250 68 Řež (Czech Republic); Bogdzel, A.A.; Churakov, A.V. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 14980 Dubna (Russian Federation); Farkas, G. [Charles University in Prague, Department of Physics of Material, Ke Karlovu 5, CZ-12116 Prague (Czech Republic); Hervoches, Ch.; Lukas, P. [Nuclear Physics Institute of the CAS v.v.i., Řež 130, 250 68 Řež (Czech Republic); Pilch, J. [Nuclear Physics Institute of the CAS v.v.i., Řež 130, 250 68 Řež (Czech Republic); Institute of Physics, Czech Academy of Sciences, Na Slovance 1992/2, 1822 Prague (Czech Republic); Saroun, J.; Strunz, P. [Nuclear Physics Institute of the CAS v.v.i., Řež 130, 250 68 Řež (Czech Republic); Zhuravlev, V.V. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 14980 Dubna (Russian Federation)

    2017-01-01

    Three neutron instruments at the Neutron Physics Laboratory (NPL) in Řež near Prague — small-angle scattering (SANS) MAUD, strain scanner SPN-100 and strain diffractometer TKSN-400 — have been modernized recently with new 2D position-sensitive detectors (PSDs) from JINR, Dubna. Here we report on the progress made in relation to the possibilities of the diffractometers due to the improved performance of the detectors. The first part of the paper is dedicated to a detailed description of the hardware and software of the PSDs, as well as its integration with the in-house experimental control software. Then practical examples of neutron scattering experiments for each of the upgraded facilities are presented.

  2. Status report of BL08 superHRPD

    International Nuclear Information System (INIS)

    Torii, Shuki

    2010-01-01

    At the end of May in 2008, the first neutron was produced successfully from a spallation neutron source in Japan Proton Accelerator Research Complex (J-PARC). High resolution Bragg reflections were obtained using the Sirius diffractometer chamber at Super High Resolution Powder Diffractometer (SuperHARD) beam line at Materials and Life Science Experimental Facility (MLF). We started up quickly by using the existing Sirius chamber, and had succeeded in achieving resolution as Δd/d=0.035 %, the best among all the entire neutron powder diffractometers in the world. About 300 detectors had been installed in the backward detector bank, and several standard samples had been measured. Simultaneously, we were carrying out basic study to design and construct a new SuperHRPD chamber, and the Sirius chamber had been exchanged for new one in summer of 2009. In the design of a new chamber, a detector solid angle is increased, d-range/Q-range is expanded, and also has options of high-intensity mode and high-resolution mode with incident collimations. (author)

  3. Neutron scattering at the high-flux isotope reactor

    International Nuclear Information System (INIS)

    Cable, J.W. Chakoumakos, B.C.; Dai, P.

    1995-01-01

    The title facilities offer the brightest source of neutrons in the national user program. Neutron scattering experiments probe the structure and dynamics of materials in unique and complementary ways as compared to x-ray scattering methods and provide fundamental data on materials of interest to solid state physicists, chemists, biologists, polymer scientists, colloid scientists, mineralogists, and metallurgists. Instrumentation at the High- Flux Isotope Reactor includes triple-axis spectrometers for inelastic scattering experiments, a single-crystal four diffractometer for crystal structural studies, a high-resolution powder diffractometer for nuclear and magnetic structure studies, a wide-angle diffractometer for dynamic powder studies and measurements of diffuse scattering in crystals, a small-angle neutron scattering (SANS) instrument used primarily to study structure-function relationships in polymers and biological macromolecules, a neutron reflectometer for studies of surface and thin-film structures, and residual stress instrumentation for determining macro- and micro-stresses in structural metals and ceramics. Research highlights of these areas will illustrate the current state of neutron science to study the physical properties of materials

  4. Neutron scattering. Annual progress report 1997; Neutronenstreuung. Annual progress report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Allenspach, P.; Boeni, B.; Fischer, P.; Furrer, A. [Eidgenoessische Technische Hochschule, Zurich (Switzerland). Lab. fuer Neutronenstreuung

    1998-02-01

    The present progress report describes the scientific and technical activities obtained by LNS staff members in 1997. It also includes the work performed by external groups at our CRG instruments D1A and IN3 at the ILL Grenoble. Due to the outstanding properties of neutrons and x-rays the research work covered many areas of science and materials research. The highlight of the year 1997 was certainly the production of neutrons at the new spallation neutron source SINQ. From July to November, SINQ was operating for typically two days/week and allowed the commissioning of four instruments at the neutron guide system: - the triple-axis spectrometer Druechal, - the powder diffractometer DMC, - the double-axis diffractometer TOPSI, the polarised triple-axis spectrometer TASP. These instruments are now fully operational and have already been used for condensed matter studies, partly in cooperation with external groups. Five further instruments are in an advanced state, and their commissioning is expected to occur between June and October 1998: - the high-resolution powder diffractometer HRPT, - the single-crystal diffractometer TriCS, - the time-of-flight spectrometer FOCUS, - the reflectometer AMOR, - the neutron optical bench NOB. Together with the small angle neutron scattering facility SANS operated by the spallation source department, all these instruments will be made available to external user groups in the future. (author) figs., tabs., refs.

  5. Neutron scattering. Annual progress report 1997

    International Nuclear Information System (INIS)

    Allenspach, P.; Boeni, B.; Fischer, P.; Furrer, A.

    1998-02-01

    The present progress report describes the scientific and technical activities obtained by LNS staff members in 1997. It also includes the work performed by external groups at our CRG instruments D1A and IN3 at the ILL Grenoble. Due to the outstanding properties of neutrons and x-rays the research work covered many areas of science and materials research. The highlight of the year 1997 was certainly the production of neutrons at the new spallation neutron source SINQ. From July to November, SINQ was operating for typically two days/week and allowed the commissioning of four instruments at the neutron guide system: - the triple-axis spectrometer Druechal, - the powder diffractometer DMC, - the double-axis diffractometer TOPSI, the polarised triple-axis spectrometer TASP. These instruments are now fully operational and have already been used for condensed matter studies, partly in cooperation with external groups. Five further instruments are in an advanced state, and their commissioning is expected to occur between June and October 1998: - the high-resolution powder diffractometer HRPT, - the single-crystal diffractometer TriCS, - the time-of-flight spectrometer FOCUS, - the reflectometer AMOR, - the neutron optical bench NOB. Together with the small angle neutron scattering facility SANS operated by the spallation source department, all these instruments will be made available to external user groups in the future. (author) figs., tabs., refs

  6. Status of neutron scattering in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sangariyavanich, Archara; Pongkasem, Somchai; Patchar, Suriya; Ampornrat, Pantip [Office of Atomic Energy for Peace, Chatuchak, Bangkok (Thailand)

    2001-03-01

    In 1992, the Office of Atomic Energy for Peace had established a spectrometer upgrade program, the main objective was to improve the performance of the old double-axis spectrometer which used to be situated at TRR1. At present, installation and alignment of the upgraded diffractometer have been accomplished. This report gives brief description about the current status of the facility. In addition, the Office of Atomic Energy is in process of constructing a 10 MW nuclear research reactor at the Ongkharak Nuclear Research Center site. The reactor will be equipped with a High Resolution Powder Diffractometer which is anticipated to be in operation soon after the commission of the reactor. Feature of the HRPD including its potential utilization are presented in this report. (author)

  7. Neutron beam applications

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Lee, J. S.; Seong, B. S.

    2000-05-01

    For the materials science by neutron technique, the development of the various complementary neutron beam facilities at horizontal beam port of HANARO and the techniques for measurement and analysis has been performed. High resolution powder diffractometer, after the installation and performance test, has been opened and used actively for crystal structure analysis, magnetic structure analysis, phase transition study, etc., since January 1998. The main components for four circle diffractometer were developed and, after performance test, it has been opened for crystal structure analysis and texture measurement since the end of 1999. For the small angle neutron spectrometer, the main component development and test, beam characterization, and the preliminary experiment for the structure study of polymer have been carried out. Neutron radiography facility, after the precise performance test, has been used for the non-destructive test of industrial component. Addition to the development of main instruments, for the effective utilization of those facilities, the scattering techniques relating to quantitative phase analysis, magnetic structure analysis, texture measurement, residual stress measurement, polymer study, etc, were developed. For the neutron radiography, photographing and printing technique on direct and indirect method was stabilized and the development for the real time image processing technique by neutron TV was carried out. The sample environment facilities for low and high temperature, magnetic field were also developed

  8. Time-of-flight small-angle-neutron-scattering data reduction and analysis at LANSCE (Los Alamos Neutron Scattering Center) with program SMR

    International Nuclear Information System (INIS)

    Hjelm, R.P. Jr.; Seegar, P.A.

    1989-01-01

    A user-friendly, integrated system, SMR, for the display, reduction and analysis of data from time-of-flight small-angle neutron diffractometers is described. Its purpose is to provide facilities for data display and assessment and to provide these facilities in near real time. This allows the results of each scattering measurement to be available almost immediately, and enables the experimenter to use the results of a measurement as a basis for other measurements in the same instrument allocation. 8 refs., 11 figs

  9. Neutron diffraction studies on ordered and disordered materials

    International Nuclear Information System (INIS)

    Krishna, P.S.R

    2016-01-01

    Knowledge of the symmetry and distribution of atoms in the unit cell and the bonding between atoms is the key point for understanding, designing and manipulating chemical behavior or physical properties of novel materials for technological applications. This could be achieved using diffraction techniques. At the Dhruva national facility, BARC, Mumbai, a Powder diffractometer (PD2) and a High-Q diffractometer (HQD) are in operation for more than 2 decades. PD2 and HQD are equipped with banks of 5 and 10 position sensitive detectors (PSD) respectively, to cover the Q-ranges 9.4 Å -1 and 15 Å -1 respectively. The resolutions (Δd/d) of these instruments are 0.8% (λ = 1.24 Å) and 2.5% (λ = 0.78 Å). We report about the studies of changes in the long range order in crystalline materials as a function of temperature and/or composition as well as short and intermediate range orders studied in amorphous materials on these diffractometers in recent years. PD2 has been extensively used in the structural/phase transition studies of ferroics, multiferroics, nanoferrites along with magnetic structure determinations. On the other hand, HQD has been extensively used to understand the short and intermediate range order in network glasses like chalcogenides, H-bonded alcohols, Telluride glasses etc. We will be discussing the recent structural results obtained on many of these crystalline systems, glasses and molecular fluids on both of these diffractometers. (author)

  10. Current Status and Future Works of Neutron Scattering Laboratory at BATAN in Serpong

    International Nuclear Information System (INIS)

    Ikram, A.

    2008-01-01

    Current status of neutron beam instruments using neutrons produced by the Multi Purpose Research Reactor--30MWth (MPR 30, RSG GA Siwabessy) located in Serpong is presented. Description of the reactor as the neutron source is mentioned briefly. There are six neutron beam tubes coming from the beryllium reflector surrounding half of the reactor core providing neutrons in the experimental hall of the reactor (XHR). Four of them are dedicated to R and D in materials science using neutron scattering techniques. Neutron Radiography Facility (NRF), Triple Axis Spectrometer (TAS) and Residual Stress Measurement (RSM) Diffractometer are installed respectively at beam tubes S2, S4 and S6. The largest neutron beam tube (S5) is exploited to accommodate two neutron guide tubes that transfer the neutrons to a neighbouring building called neutron guide hall (NGH). There are three other neutron beam instruments installed in this building, namely Small Angle Neutron Scattering (SANS) Spectrometer (SMARTer), High Resolution SANS (HRSANS) Spectrometer and High Resolution Powder Diffractometer (HRPD). In the XHR, a Four Circle and Texture Diffractometer (FCD/TD) is attached to one of the neutron guide tubes. These seven instruments were installed to utilize the neutrons for materials science research, and recently the RSM diffractometer has shown its capabilities in identifying different amount of stress left due to different treatments of welding in fuel cladding, while the SANS spectrometer is now gaining capabilities in identifying different sizes and shapes of macromolecules in polymers as well as investigations of magnetic samples. In the mean time, non-destructive tests using the NRF is gathering more confidence from some latest real time measurements eventhough there are still some shortcomings in the components and their alignments. Future works including improvement of each facility and its components, even replacement of some parts are necessary and have to be carried out

  11. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  12. Time-of-flight small-angle neutron scattering data reduction and analysis at LANSCE with program SMR

    International Nuclear Information System (INIS)

    Hjelm, R.P. Jr.; Seeger, P.A.

    1988-01-01

    A user-friendly integrated system, SMR, for the display, reduction and analysis of data from time-of-flight small-angle neutron diffractometers is described. Its purpose is to provide facilities for data display and assessment, and to provide these facilities in near real time. This allows the results of each scattering measurement to be available almost immediately, and enables the user to use the results of a measurement as a basis for other measurements in the same time allocation of the instrument. 8 refs., 10 figs

  13. The APS optics topography station

    International Nuclear Information System (INIS)

    Krasnicki, S.

    1996-01-01

    An in-house station for topographic testing of x-ray optical elements for the Advanced Photon Source experimental beamlines was set up by the Experimental Facilities Division of Argonne National Laboratory. A new double-crystal x-ray diffractometer was designed and built keeping in mind the need for testing large crystals possibly attached to cooling manifolds and lines. A short description of the new facility is given. The instrument performance fully satisfies imposed requirements, and the machine was successfully used for testing several silicon and diamond crystals

  14. Self-assembly of self-assembled molecular triangles

    Indian Academy of Sciences (India)

    SB/S1/IC-05/2014) for providing financial support to our research endeav- ours. We gratefully acknowledge the single crystal X- ray diffractometer facility funded by IIT Madras. References. 1. (a) Cook T R, Zheng Y-R and Stang P J 2013 Chem. Rev. 113 734; (b) Debata N B, Tripathy D and Chand. D K 2012 Coord. Chem.

  15. Overview and perspective of materials characterization by using synchrotron radiation

    International Nuclear Information System (INIS)

    Kamitsubo, Hiromichi

    2009-01-01

    A peculiarity of techniques and the methods of synchrotron radiation are explained. It consists of five sections such as introduction, synchrotron radiation, interaction between X-ray and materials, analytical methods of materials using synchrotron radiation and perspective and problems. The second section described the principles of synchrotron orbit radiation, synchrotron light source, the main formulae and schematic drawing of undulator, and the synchrotron radiation facilities in Japan. The third section explained behavior of X-ray in materials, absorption, reflection, refraction and scattering of X-ray. The fourth section stated many analytical methods of materials; the surface diffractometer, powder diffractometer, high-energy X-ray diffraction, core-electron absorption spectroscopy, micro-beam diffraction, X-ray fluorescence, X-ray absorption fine structure (XAFS), and photoemission spectroscopy (PES). A characteristic feature of synchrotron radiation contains the large wave length ranges from infrared to X-ray, high directivity and brightness, linear (circular) polarization, pulsed light, good control and stability. The brightness spectra of Spring-8 and SAGA-LS, concept of synchrotron light source, undulator and wiggler, nine synchrotron radiation facilities in Japan, mass absorption coefficients of Cu and Au, and analysis of materials using synchrotron radiation are illustrated. (S.Y.)

  16. 4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot

    Science.gov (United States)

    2012-01-01

    Background To assess changes in right heart flow and pulmonary artery hemodynamics in patients with repaired Tetralogy of Fallot (rTOF) we used whole heart, four dimensional (4D) velocity mapping (VM) cardiovascular magnetic resonance (CMR). Methods CMR studies were performed in 11 subjects with rTOF (5M/6F; 20.1 ± 12.4 years) and 10 normal volunteers (6M/4F; 34.2 ± 13.4 years) on clinical 1.5T and 3.0T MR scanners. 4D VM-CMR was performed using PC VIPR (Phase Contrast Vastly undersampled Isotropic Projection Reconstruction). Interactive streamline and particle trace visualizations of the superior and inferior vena cava (IVC and SVC, respectively), right atrium (RA), right ventricle (RV), and pulmonary artery (PA) were generated and reviewed by three experienced readers. Main PA net flow, retrograde flow, peak flow, time-to-peak flow, peak acceleration, resistance index and mean wall shear stress were quantified. Differences in flow patterns between the two groups were tested using Fisher's exact test. Differences in quantitative parameters were analyzed with the Kruskal-Wallis rank sum test. Results 4D VM-CMR was successfully performed in all volunteers and subjects with TOF. Right heart flow patterns in rTOF subjects were characterized by (a) greater SVC/IVC flow during diastole than systole, (b) increased vortical flow patterns in the RA and in the RV during diastole, and (c) increased helical or vortical flow features in the PA's. Differences in main PA retrograde flow, resistance index, peak flow, time-to-peak flow, peak acceleration and mean wall shear stress were statistically significant. Conclusions Whole heart 4D VM-CMR with PC VIPR enables detection of both normal and abnormal right heart flow patterns, which may allow for comprehensive studies to evaluate interdependencies of post-surgically altered geometries and hemodynamics. PMID:22313680

  17. Construction and maintenance of SUNY facilities at the National Synchrotron Light Source. Progress report, 1 October 1981-1 July 1982

    International Nuclear Information System (INIS)

    Bigeleisen, J.

    1982-01-01

    Development of the SUNY beam line at the National Synchrotron Light Source is described. The line now includes monochromator/mirror optics with tandem arrangement of experiments. The beamline computer system is now working with CAMAC data acquisition, and a four-circle diffractometer, a small-angle-scattering bench, and a fluorescence EXAFS apparatus should be ready soon

  18. Facile Oxidative Desulfurisation of Benzothiophene Using Polyoxometalate H4[α-SiW12O40]/Zr Catalyst

    Directory of Open Access Journals (Sweden)

    Aldes Lesbani

    2015-07-01

    Full Text Available A highly active catalyst H4[α-SiW12O40]/Zr based polyoxometalete Keggin type was prepared by wet impregnation method and was characterized by FTIR spectroscopy, X-ray diffractometer, surface textural property by SEM, and analysis of porosity by BET method. H4[α-SiW12O40]/Zr was successfully synthesized and showed uniform properties with block solid structure which was applied as heterogeneous stable catalyst for oxidative desulfurization of benzothiophene under simple and mild condition using H2O2 as oxidant. Facile conversion of benzothiophene to sulfone by using heterogeneus                    H4[α-SiW12O40]/Zr catalyst up to 99% was observed to show the active catalytically. Keggin             H4[α-SiW12O40]/Zr cage structure after reaction was different from fresh catalyst which was indicated by the instability of H4[α-SiW12O40]/Zr  under reaction condition. © 2015 BCREC UNDIP. All rights reservedReceived: 9th November 2014; Revised: 31st March 2015; Accepted: 23rd April 2015How to Cite: Lesbani, A., Agnes, A., Saragih, R.O., Verawaty, M., Mohadi, R., Zulkifli, H. (2015.    Facile Oxidative Desulfurisation of Benzothiophen Using Polyoxometalate H4[α-SiW12O40]/Zr Catalyst. Bulletin of Chemical Reaction Engineering & Catalysis, 10 (2, 185-191. (doi:10.9767/bcrec.10.2.7734.185-191 Permalink/DOI: http://dx.doi.org/10.9767/bcrec.10.2.7734.185-191 

  19. Emission Facilities - Erosion & Sediment Control Facilities

    Data.gov (United States)

    NSGIC Education | GIS Inventory — An Erosion and Sediment Control Facility is a DEP primary facility type related to the Water Pollution Control program. The following sub-facility types related to...

  20. Facile Oxidative Desulfurisation of Benzothiophene Using Polyoxometalate H4[α-SiW12O40]/Zr Catalyst

    OpenAIRE

    Aldes Lesbani; A. Agnes; Randi O. Saragih; Mariska Verawaty; Risfidian Mohadi; Hilda Zulkifli

    2015-01-01

    A highly active catalyst H4[α-SiW12O40]/Zr based polyoxometalete Keggin type was prepared by wet impregnation method and was characterized by FTIR spectroscopy, X-ray diffractometer, surface textural property by SEM, and analysis of porosity by BET method. H4[α-SiW12O40]/Zr was successfully synthesized and showed uniform properties with block solid structure which was applied as heterogeneous stable catalyst for oxidative desulfurization of benzothiophene under simple and mild condition using...

  1. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  2. Assessment of Diffuse Ventricular Myocardial Fibrosis Using Native T1 in Children With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yim, Deane; Riesenkampff, Eugenie; Caro-Dominguez, Pablo; Yoo, Shi-Joon; Seed, Mike; Grosse-Wortmann, Lars

    2017-03-01

    Myocardial fibrosis is linked with adverse clinical outcomes in adults after tetralogy of Fallot repair (rTOF). Native T1 times (T1) by cardiac magnetic resonance have been shown to be a surrogate marker of diffuse myocardial fibrosis. The objective was to quantify native T1 in children post-rTOF and to evaluate their relationship with surgical, imaging, and clinical factors. A retrospective cross-sectional study was performed. Midventricular native T1 were obtained in 100 children post-rTOF using a modified look-locker inversion recovery cardiac magnetic resonance sequence and compared with 35 pediatric controls. rTOF patients, aged 13.0±2.9 years, had higher indexed right ventricular (RV) end-diastolic (range 85-326 mL/m 2 , mean 148 mL/m 2 ) volumes, and lower RV and left ventricular (LV) ejection fractions compared with controls. RV, but not LV, T1 were higher in patients than in controls (1031±74 versus 954±32 ms, P <0.001) and female patients had higher RV T1 compared with males (1051±79 versus 1017±68 ms, P =0.02). LV T1 correlated with RV T1 ( r =0.45, P <0.001), cardiopulmonary bypass ( r =0.30, P =0.007), and aortic cross-clamp times ( r =0.32, P =0.004). RV T1 correlated inversely with RV outflow tract gradient ( r =-0.28, P =0.02). Longer aortic cross-clamp times were independently associated with LV and RV T1 on multivariable analysis. There was no association between exercise intolerance, arrhythmia, and native T1 or LV extracellular volume. Children after rTOF do not have elevated LV native T1 or LV extracellular volume, but show evidence of increased RV native T1 suggestive of diffuse RV fibrosis, for which volume loading seems to be a risk factor. Surgical bypass and cross-clamp times are associated with fibrotic remodeling over a decade later. © 2017 American Heart Association, Inc.

  3. Chemical Composition of the Semi-Volatile Grains of Comet 67P/Churyumov-Gerasimenko

    Science.gov (United States)

    Wurz, P.; Altwegg, K.; Balsiger, H. R.; Berthelier, J. J.; De Keyser, J.; Fiethe, B.; Fuselier, S. A.; Gasc, S.; Gombosi, T. I.; Korth, A.; Mall, U.; Reme, H.; Rubin, M.; Tzou, C. Y.

    2017-12-01

    Rosetta was in orbit of comet 67P/Churyumov-Gerasimenko from August 2014 to September 2016. On board is the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) experiment that has been continuously collecting data on the chemical composition and activity of the coma from 3.5 AU to pericentre at 1.24 AU and out again to 3.5 AU. ROSINA consists of two mass spectrometers, the Double Focusing Mass Spectrometer (DFMS) and the Reflectron-type Time-Of-Flight (RTOF), as well as the COmet Pressure Sensor (COPS). ROSINA recorded the neutral gas and thermal plasma in the comet's coma. The two mass spectrometers have high dynamic ranges and complement each other with high mass resolution, and high time resolution and large mass range. COPS measures total gas densities, bulk velocities, and gas temperatures. Occasionally, a dust grain of cometary origin enters the ion source of a ROSINA instrument where the volatile part evaporates since these ion sources are hot. The release of volatiles from cometary dust grains was observed with all three ROSINA instruments on several occasions. Because the volatile content of such a dust grain is completely evaporated after a few seconds, the RTOF instrument is best suited for the investigation of its chemical composition since complete mass spectra are recorded during this time. During the mission 9 dust grains were observed with RTOF during the October 2014 to July 2016 time period. It is estimated that these grains contain about 10-15 g of volatiles. The mass spectra were interpreted with a set of 75 molecules, with the major groups of chemical species being hydrocarbons, oxygenated hydrocarbons, nitrogen-bearing molecules, sulphur-bearing molecules, halogenated molecules and others. About 70% of these grains are depleted in water compared to the comet coma, thus, can be considered as semi-volatile dust grains, and the other about 30% are water grains. The chemical composition varies considerably from grain to grain

  4. Comparative study of structural properties of trehalose water solutions by neutron diffraction, synchrotron radiation and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Cesaro, A.; Magazu, V.; Migliardo, F.; Sussich, F.; Vadala, M

    2004-07-15

    Neutron diffraction measurements combined with H/D substitution have been performed on trehalose aqueous solutions as a function of temperature and concentration by using the SANDALS diffractometer at ISIS Facility (UK). The findings point out a high capability of trehalose to strongly affect the tetrahedral hydrogen bond network of water. The neutron diffraction results are also compared with simulation and experimental data obtained by synchrotron radiation on the phospholipid bilayer membranes (DPPC)/trehalose/H{sub 2}O ternary system.

  5. Earth, soil and environmental science research facility at sector 13 of the Advanced Photon Source. II. Scientific program and experimental instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Sutton, S.; Eng., P.J.; Jaski, Y.R.; Lazaraz, N.; Pluth, J.; Murray, P.; Rarback, H.; Rivers, M. [CARS, 5640 S. Ellis Avenue, University of Chicago, Chicago, IL (United States)

    1996-09-01

    The GSECARS (APS sector 13) scientific program will provide fundamental new information on the deep structure and composition of the Earth and other planets, the formation of economic mineral deposits, the cycles and fate of toxic metals in the environment, and the mechanisms of nutrient uptake and disease in plants. In the four experimental stations (2 per beamline), scientists will have access to three main x-ray techniques: diffraction (microcrystal, powder, diamond anvil cell, and large volume press), fluorescence microprobe, and spectroscopy (conventional, microbeam, liquid and solid surfaces). The high pressure facilities will be capable of x-ray crystallography at P{approx_gt}360 GPa and T{approximately}6000 K with the diamond anvil cell and P{approximately}25 GPa and T{approximately}2500{degree}C with the large volume press. Diffractometers will allow study of 1 micrometer crystals and micro-powders. The microprobe (1 micrometer focused beam) will be capable of chemical analyses in the sub-ppm range using wavelength and energy dispersive detectors. Spectroscopy instrumentation will be available for XANES and EXAFS with microbeams as well as high sensitivity conventional XAS and studies of liquid and solid interfaces. Visiting scientists will be able to setup, calibrate, and test experiments in off-line laboratories with equipment such as micromanipulators, optical microscopes, clean bench, glove boxes, high powered optical and Raman spectrometers. {copyright} {ital 1996 American Institute of Physics.}

  6. Dance Facilities.

    Science.gov (United States)

    Ashton, Dudley, Ed.; Irey, Charlotte, Ed.

    This booklet represents an effort to assist teachers and administrators in the professional planning of dance facilities and equipment. Three chapters present the history of dance facilities, provide recommended dance facilities and equipment, and offer some adaptations of dance facilities and equipment, for elementary, secondary and college level…

  7. Facilities inventory protection for nuclear facilities

    International Nuclear Information System (INIS)

    Schmitt, F.J.

    1989-01-01

    The fact that shut-down applications have been filed for nuclear power plants, suggests to have a scrutinizing look at the scopes of assessment and decision available to administrations and courts for the protection of facilities inventories relative to legal and constitutional requirements. The paper outlines the legal bases which need to be observed if purposeful calculation is to be ensured. Based on the different actual conditions and legal consequences, the author distinguishes between 1) the legal situation of facilities licenced already and 2) the legal situation of facilities under planning during the licencing stage. As indicated by the contents and restrictions of the pertinent provisions of the Atomic Energy Act and by the corresponding compensatory regulation, the object of the protection of facilities inventor in the legal position of the facility owner within the purview of the Atomic Energy Act, and the licensing proper. Art. 17 of the Atomic Energy Act indicates the legislators intent that, once issued, the licence will be the pivotal point for regulations aiming at protection and intervention. (orig./HSCH) [de

  8. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2012-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, the neutron polarization analyzer DNS, the neutron spin-echo spectrometer J-NSE, the small-angle neutron diffractometers KWS-1/-2, the very-small-angle neutron diffractometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  9. Position controller for the arm of a neutron diffractometer using fuzzy logic; Controlador de posicion del brazo del difractometro de neutrones utilizando logica difusa

    Energy Technology Data Exchange (ETDEWEB)

    Ayala P, G F [Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico)

    1994-12-31

    The neutron diffractometer is an important instrument coupled to one of the radial outlets of the TRIGA-3-Salazar Reactor and is used mainly to analyze textures and crystal lattices. One of its main components is the velocity analysis goniometer which controls in a tangential way the movements of the sensor requiring for this a resolution of a hundredth of degree, but at the same time wide displacements are required. It is necessary to design and construct a system on the basis of a micro controller which control the long movements in a rapid way and with the needed accuracy. In this work, a proposition is presented: to replace the A.C. motor with a D.C. motor with a wide range of velocity and supplied with a card (DAC) to control the velocity by means of digital data. Moreover, a programmed micro controller with an algorithm based on fuzzy logic receiving data in BCD will be use. The use of micro controller will allow to set free the personal computer of the position of the goniometer; nevertheless, the system will report to the P C and its control program about the present position of the goniometer and the time when the desired position is reached. It is also consider that the user will be away from the system (a minimum of 15 meters) in order to avoid the zone with a high intensity of background radiation. (Author).

  10. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  11. Facilities & Leadership

    Data.gov (United States)

    Department of Veterans Affairs — The facilities web service provides VA facility information. The VA facilities locator is a feature that is available across the enterprise, on any webpage, for the...

  12. Facility model for the Los Alamos Plutonium Facility

    International Nuclear Information System (INIS)

    Coulter, C.A.; Thomas, K.E.; Sohn, C.L.; Yarbro, T.F.; Hench, K.W.

    1986-01-01

    The Los Alamos Plutonium Facility contains more than sixty unit processes and handles a large variety of nuclear materials, including many forms of plutonium-bearing scrap. The management of the Plutonium Facility is supporting the development of a computer model of the facility as a means of effectively integrating the large amount of information required for material control, process planning, and facility development. The model is designed to provide a flexible, easily maintainable facility description that allows the faciltiy to be represented at any desired level of detail within a single modeling framework, and to do this using a model program and data files that can be read and understood by a technically qualified person without modeling experience. These characteristics were achieved by structuring the model so that all facility data is contained in data files, formulating the model in a simulation language that provides a flexible set of data structures and permits a near-English-language syntax, and using a description for unit processes that can represent either a true unit process or a major subsection of the facility. Use of the model is illustrated by applying it to two configurations of a fictitious nuclear material processing line

  13. Animal facilities

    International Nuclear Information System (INIS)

    Fritz, T.E.; Angerman, J.M.; Keenan, W.G.; Linsley, J.G.; Poole, C.M.; Sallese, A.; Simkins, R.C.; Tolle, D.

    1981-01-01

    The animal facilities in the Division are described. They consist of kennels, animal rooms, service areas, and technical areas (examining rooms, operating rooms, pathology labs, x-ray rooms, and 60 Co exposure facilities). The computer support facility is also described. The advent of the Conversational Monitor System at Argonne has launched a new effort to set up conversational computing and graphics software for users. The existing LS-11 data acquisition systems have been further enhanced and expanded. The divisional radiation facilities include a number of gamma, neutron, and x-ray radiation sources with accompanying areas for related equipment. There are five 60 Co irradiation facilities; a research reactor, Janus, is a source for fission-spectrum neutrons; two other neutron sources in the Chicago area are also available to the staff for cell biology studies. The electron microscope facilities are also described

  14. Facilities Performance Indicators Report 2013-14: Tracking Your Facilities Vital Signs

    Science.gov (United States)

    APPA: Association of Higher Education Facilities Officers, 2015

    2015-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA: Association of Higher Education Facilities Officers (APPA's) Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance…

  15. Communication grounding facility

    International Nuclear Information System (INIS)

    Lee, Gye Seong

    1998-06-01

    It is about communication grounding facility, which is made up twelve chapters. It includes general grounding with purpose, materials thermal insulating material, construction of grounding, super strength grounding method, grounding facility with grounding way and building of insulating, switched grounding with No. 1A and LCR, grounding facility of transmission line, wireless facility grounding, grounding facility in wireless base station, grounding of power facility, grounding low-tenton interior power wire, communication facility of railroad, install of arrester in apartment and house, install of arrester on introduction and earth conductivity and measurement with introduction and grounding resistance.

  16. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  17. Facility effluent monitoring plan for the 325 Facility

    International Nuclear Information System (INIS)

    1998-01-01

    The Applied Chemistry Laboratory (325 Facility) houses radiochemistry research, radioanalytical service, radiochemical process development, and hazardous and mixed hazardous waste treatment activities. The laboratories and specialized facilities enable work ranging from that with nonradioactive materials to work with picogram to kilogram quantities of fissionable materials and up to megacurie quantities of other radionuclides. The special facilities include two shielded hot-cell areas that provide for process development or analytical chemistry work with highly radioactive materials, and a waste treatment facility for processing hazardous, mixed, low-level, and transuranic wastes generated by Pacific Northwest Laboratory. Radioactive material storage and usage occur throughout the facility and include a large number of isotopes. This material is in several forms, including solid, liquid, particulate, and gas. Some of these materials are also heated during testing which can produce vapors. The research activities have been assigned to the following activity designations: High-Level Hot Cell, Hazardous Waste Treatment Unit, Waste Form Development, Special Testing Projects, Chemical Process Development, Analytical Hot Cell, and Analytical Chemistry. The following summarizes the airborne and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  18. X-ray diffraction using synchrotron radiation on the G.I.L.D.A. beam line at the E.S.R.F

    Energy Technology Data Exchange (ETDEWEB)

    Balerna, A [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Meneghini, C [INFN, Laboratori Nazionali di Frascati, Rome (Italy); [INFM, Genoa (Italy); Bordoni, S [Rome Univ. ` Tor Vergata` (Italy). Dip. di Fisica; Mobilio, S [Rome Univ. III (Italy). Dip. di Fisica ` E. Amaldi`

    1996-09-01

    The aim of this lecture is to make a short introduction on Synchrotron radiation, its history and main properties. The main components of a synchrotron radiation beam line will be described. The Italian beam line, General purpose Italian beam line Line for Diffraction and Absorption (G.I.L.D.A.) at the European Synchrotron Radiation Facility (E.S.R.F.) in Grenoble will be used as an example. The G.I.L.D.A. diffractometer will be described in detail reporting also some experimental results.

  19. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research FacilityFacilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  20. Facilities Performance Indicators Report, 2004-05. Facilities Core Data Survey

    Science.gov (United States)

    Glazner, Steve, Ed.

    2006-01-01

    The purpose of "Facilities Performance Indicators" is to provide a representative set of statistics about facilities in educational institutions. The second iteration of the web-based Facilities Core Data Survey was posted and available to facilities professionals at more than 3,000 institutions in the Fall of 2005. The website offered a printed…

  1. High-risk facilities. Emergency management in nuclear, chemical and hazardous waste facilities

    International Nuclear Information System (INIS)

    Kloepfer, Michael

    2012-01-01

    The book on emergency management in high-risk facilities covers the following topics: Change in the nuclear policy, risk management of high-risk facilities as a constitutional problem - emergency management in nuclear facilities, operational mechanisms of risk control in nuclear facilities, regulatory surveillance responsibilities for nuclear facilities, operational mechanism of the risk control in chemical plants, regulatory surveillance responsibilities for chemical facilities, operational mechanisms of the risk control in hazardous waste facilities, regulatory surveillance responsibilities for hazardous waste facilities, civil law consequences in case of accidents in high-risk facilities, criminal prosecution in case of accidents in high-risk facilities, safety margins as site risk for emission protection facilities, national emergency management - strategic emergency management structures, warning and self-protection of the public in case of CBRN hazards including aspects of the psych-social emergency management.

  2. Nuclear facilities

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    Here is given the decree (2000-1065) of the 25. of October 2000 reporting the publication of the convention between the Government of the French Republic and the CERN concerning the safety of the LHC (Large Hadron Collider) and the SPS (Proton Supersynchrotron) facilities, signed in Geneva on July 11, 2000. By this convention, the CERN undertakes to ensure the safety of the LHC and SPS facilities and those of the operations of the LEP decommissioning. The French legislation and regulations on basic nuclear facilities (concerning more particularly the protection against ionizing radiations, the protection of the environment and the safety of facilities) and those which could be decided later on apply to the LHC, SPS and auxiliary facilities. (O.M.)

  3. Facility effluent monitoring plan for 242-A Evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1993-03-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility effluent Monitoring Plans, WHC-EP-0438-1**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  4. North Slope, Alaska ESI: FACILITY (Facility Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for oil field facilities for the North Slope of Alaska. Vector points in this data set represent oil field facility locations. This data...

  5. 26 CFR 1.142(a)(5)-1 - Exempt facility bonds: Sewage facilities.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Exempt facility bonds: Sewage facilities. 1.142... Bonds § 1.142(a)(5)-1 Exempt facility bonds: Sewage facilities. (a) In general. Under section 103(a), a... in section 142(a) is a sewage facility. This section defines the term sewage facility for purposes of...

  6. Facility transition instruction

    International Nuclear Information System (INIS)

    Morton, M.R.

    1997-01-01

    The Bechtel Hanford, Inc. facility transition instruction was initiated in response to the need for a common, streamlined process for facility transitions and to capture the knowledge and experience that has accumulated over the last few years. The instruction serves as an educational resource and defines the process for transitioning facilities to long-term surveillance and maintenance (S and M). Generally, these facilities do not have identified operations missions and must be transitioned from operational status to a safe and stable configuration for long-term S and M. The instruction can be applied to a wide range of facilities--from process canyon complexes like the Plutonium Uranium Extraction Facility or B Plant, to stand-alone, lower hazard facilities like the 242B/BL facility. The facility transition process is implemented (under the direction of the US Department of Energy, Richland Operations Office [RL] Assistant Manager-Environmental) by Bechtel Hanford, Inc. management, with input and interaction with the appropriate RL division and Hanford site contractors as noted in the instruction. The application of the steps identified herein and the early participation of all organizations involved are expected to provide a cost-effective, safe, and smooth transition from operational status to deactivation and S and M for a wide range of Hanford Site facilities

  7. Facilities Performance Indicators Report 2012-13: Tracking Your Facilities Vital Signs

    Science.gov (United States)

    APPA: Association of Higher Education Facilities Officers, 2014

    2014-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance Indicators Report" is designed for survey…

  8. Guide to research facilities

    Energy Technology Data Exchange (ETDEWEB)

    1993-06-01

    This Guide provides information on facilities at US Department of Energy (DOE) and other government laboratories that focus on research and development of energy efficiency and renewable energy technologies. These laboratories have opened these facilities to outside users within the scientific community to encourage cooperation between the laboratories and the private sector. The Guide features two types of facilities: designated user facilities and other research facilities. Designated user facilities are one-of-a-kind DOE facilities that are staffed by personnel with unparalleled expertise and that contain sophisticated equipment. Other research facilities are facilities at DOE and other government laboratories that provide sophisticated equipment, testing areas, or processes that may not be available at private facilities. Each facility listing includes the name and phone number of someone you can call for more information.

  9. Experimental Fuels Facility Re-categorization Based on Facility Segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Reiss, Troy P.; Andrus, Jason

    2016-07-01

    The Experimental Fuels Facility (EFF) (MFC-794) at the Materials and Fuels Complex (MFC) located on the Idaho National Laboratory (INL) Site was originally constructed to provide controlled-access, indoor storage for radiological contaminated equipment. Use of the facility was expanded to provide a controlled environment for repairing contaminated equipment and characterizing, repackaging, and treating waste. The EFF facility is also used for research and development services, including fuel fabrication. EFF was originally categorized as a LTHC-3 radiological facility based on facility operations and facility radiological inventories. Newly planned program activities identified the need to receive quantities of fissionable materials in excess of the single parameter subcritical limit in ANSI/ANS-8.1, “Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors” (identified as “criticality list” quantities in DOE-STD-1027-92, “Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports,” Attachment 1, Table A.1). Since the proposed inventory of fissionable materials inside EFF may be greater than the single parameter sub-critical limit of 700 g of U-235 equivalent, the initial re-categorization is Hazard Category (HC) 2 based upon a potential criticality hazard. This paper details the facility hazard categorization performed for the EFF. The categorization was necessary to determine (a) the need for further safety analysis in accordance with LWP-10802, “INL Facility Categorization,” and (b) compliance with 10 Code of Federal Regulations (CFR) 830, Subpart B, “Safety Basis Requirements.” Based on the segmentation argument presented in this paper, the final hazard categorization for the facility is LTHC-3. Department of Energy Idaho (DOE-ID) approval of the final hazard categorization determined by this hazard assessment document (HAD) was required per the

  10. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    International Nuclear Information System (INIS)

    Coenenberg, J.G.

    1997-01-01

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, 'operating' treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  11. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  12. Facility effluent monitoring plan for 242-A evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years

  13. EPA Facility Registry Service (FRS): Facility Interests Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in...

  14. USANS investigation of early stages of metal foam formation

    CERN Document Server

    Bellmann, D; Banhart, J

    2002-01-01

    Metallic foams are on the verge of being used in industrial applications. However, the mechanism of foam creation, especially the early stages, are still unexplored. Ultra small-angle neutron scattering (USANS), performed with the double-crystal diffractometer (DCD) at the Geesthacht Neutron Facility (GeNF), is a promising method for obtaining a three-dimensional average of a pore size distribution in a wide size range from about 100 nm to about 20 mu m. Analysis of the neutron scattering curves yielded pore size distributions which conformed with the results obtained by microscopy. (orig.)

  15. Time-of-flight neutron diffraction investigation of temperature factors in the Zn blende semiconductor InP

    International Nuclear Information System (INIS)

    Ferrari, C.; Bocchi, C.; Fornari, R.; Moze, O.; Wilson, C.C.

    1992-01-01

    A structural investigation of the Zn blende structure semiconductor InP has been carried out using the single crystal diffractometer SXD at the pulsed neutron facility ISIS. The ability to measure structure factors accurately at large Q values even with highly absorbing materials such as InP is demonstrated. Measurements were performed on a single crystal of InP at 293, 100 and 50 K with the crystallographic axis mounted perpendicular to the scattering plane. This enabled collection of (hhl) reflections up to a maximum with Miller indices (10, 10, 8). (orig.)

  16. The upgraded JRR-3 and future scope of its utilization

    International Nuclear Information System (INIS)

    Miyasaka, Yasuhiko; Umei, Hiroshi; Takahashi, Hidetake; Sakamoto, Masanobu

    1985-10-01

    At the time of start to construct the upgraded JRR-3, the present report describes general features on the upgraded JRR-3 and future scope of its utilization on the purpose of the mutual understanding with researchers who use the reactor and the utilization facilities. The materials edited in the report have been written by 28 reactor engineers and scientists in JAERI, and 35 scientists in universities. According to the reviewed subjects as shown below, it was confirmed that the upgraded JRR-3 would be extensively expected by much more fields. (1) Reactor and utilization facilities. 1. Plan and main features of the upgraded JRR-3, Reactor building 2. Irradiation facilities: Hydraulic rabbits, Pneumatic tubes, Rig Hot Cell, etc. 3. Neutron beam facilities: Horizontal tubes, Cold neutron source and Neutron guide tubes (2) Neutron beam experimental facilities. 1. Neutron diffractometer, neutron spectrometer, Small-angle neutron scattering, Neutron radiography, etc. (3) Recent trends. 1. Irradiation research of fuels and materials in research reactor 2. Activation analysis, Radioisotope, Neutron transmutation doping, etc. 3. Neutron scattering research. (author)

  17. Biochemistry Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Biochemistry Facility provides expert services and consultation in biochemical enzyme assays and protein purification. The facility currently features 1) Liquid...

  18. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Geiger, J.L.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified. in. A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  19. Jupiter Laser Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Jupiter Laser Facility is an institutional user facility in the Physical and Life Sciences Directorate at LLNL. The facility is designed to provide a high degree...

  20. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    International Nuclear Information System (INIS)

    Simiele, G.A.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  1. Research Facilities | Wind | NREL

    Science.gov (United States)

    Research Facilities Research Facilities NREL's state-of-the-art wind research facilities at the Research Facilities Photo of five men in hard hards observing the end of a turbine blade while it's being tested. Structural Research Facilities A photo of two people silhouetted against a computer simulation of

  2. Identification of Region-Specific Myocardial Gene Expression Patterns in a Chronic Swine Model of Repaired Tetralogy of Fallot.

    Directory of Open Access Journals (Sweden)

    Sabine Charron

    Full Text Available Surgical repair of Tetralogy of Fallot (TOF is highly successful but may be complicated in adulthood by arrhythmias, sudden death, and right ventricular or biventricular dysfunction. To better understand the molecular and cellular mechanisms of these delayed cardiac events, a chronic animal model of postoperative TOF was studied using microarrays to perform cardiac transcriptomic studies. The experimental study included 12 piglets (7 rTOF and 5 controls that underwent surgery at age 2 months and were further studied after 23 (+/- 1 weeks of postoperative recovery. Two distinct regions (endocardium and epicardium from both ventricles were analyzed. Expression levels from each localization were compared in order to decipher mechanisms and signaling pathways leading to ventricular dysfunction and arrhythmias in surgically repaired TOF. Several genes were confirmed to participate in ventricular remodeling and cardiac failure and some new candidate genes were described. In particular, these data pointed out FRZB as a heart failure marker. Moreover, calcium handling and contractile function genes (SLN, ACTC1, PLCD4, PLCZ, potential arrhythmia-related genes (MYO5B, KCNA5, and cytoskeleton and cellular organization-related genes (XIRP2, COL8A1, KCNA6 were among the most deregulated genes in rTOF ventricles. To our knowledge, this is the first comprehensive report on global gene expression profiling in the heart of a long-term swine model of repaired TOF.

  3. Waste Facilities

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset was developed from the Vermont DEC's list of certified solid waste facilities. It includes facility name, contact information, and the materials...

  4. Fabrication Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Fabrication Facilities are a direct result of years of testing support. Through years of experience, the three fabrication facilities (Fort Hood, Fort Lewis, and...

  5. EPA Facility Registry Service (FRS): Facility Interests Dataset Download

    Data.gov (United States)

    U.S. Environmental Protection Agency — This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are...

  6. Irradiation Facilities at CERN

    CERN Document Server

    Gkotse, Blerina; Carbonez, Pierre; Danzeca, Salvatore; Fabich, Adrian; Garcia, Alia, Ruben; Glaser, Maurice; Gorine, Georgi; Jaekel, Martin, Richard; Mateu,Suau, Isidre; Pezzullo, Giuseppe; Pozzi, Fabio; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-01-01

    CERN provides unique irradiation facilities for applications in many scientific fields. This paper summarizes the facilities currently operating for proton, gamma, mixed-field and electron irradiations, including their main usage, characteristics and information about their operation. The new CERN irradiation facilities database is also presented. This includes not only CERN facilities but also irradiation facilities available worldwide.

  7. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in...

  8. Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility

    International Nuclear Information System (INIS)

    1993-08-01

    The 200 Area Effluent Treatment Facility Dangerous Waste Permit Application documentation consists of both Part A and a Part B permit application documentation. An explanation of the Part A revisions associated with this treatment and storage unit, including the current revision, is provided at the beginning of the Part A section. Once the initial Hanford Facility Dangerous Waste Permit is issued, the following process will be used. As final, certified treatment, storage, and/or disposal unit-specific documents are developed, and completeness notifications are made by the US Environmental Protection Agency and the Washington State Department of Ecology, additional unit-specific permit conditions will be incorporated into the Hanford Facility Dangerous Waste Permit through the permit modification process. All treatment, storage, and/or disposal units that are included in the Hanford Facility Dangerous Waste Permit Application will operate under interim status until final status conditions for these units are incorporated into the Hanford Facility Dangerous Waste Permit. The Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility contains information current as of May 1, 1993

  9. Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    The 200 Area Effluent Treatment Facility Dangerous Waste Permit Application documentation consists of both Part A and a Part B permit application documentation. An explanation of the Part A revisions associated with this treatment and storage unit, including the current revision, is provided at the beginning of the Part A section. Once the initial Hanford Facility Dangerous Waste Permit is issued, the following process will be used. As final, certified treatment, storage, and/or disposal unit-specific documents are developed, and completeness notifications are made by the US Environmental Protection Agency and the Washington State Department of Ecology, additional unit-specific permit conditions will be incorporated into the Hanford Facility Dangerous Waste Permit through the permit modification process. All treatment, storage, and/or disposal units that are included in the Hanford Facility Dangerous Waste Permit Application will operate under interim status until final status conditions for these units are incorporated into the Hanford Facility Dangerous Waste Permit. The Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility contains information current as of May 1, 1993.

  10. EPA Facility Registry Service (FRS): AIRS_AFS Sub Facilities

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Facility System (AFS) contains compliance and permit data for stationary sources regulated by EPA, state and local air pollution agencies. The sub facility...

  11. Facility effluent monitoring plan for the fast flux test facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Dahl, N.R.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in US Department of Energy Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A Facility Effluent Monitoring Plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  12. DUPIC facility engineering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J S; Choi, J W; Go, W I; Kim, H D; Song, K C; Jeong, I H; Park, H S; Im, C S; Lee, H M; Moon, K H; Hong, K P; Lee, K S; Suh, K S; Kim, E K; Min, D K; Lee, J C; Chun, Y B; Paik, S Y; Lee, E P; Yoo, G S; Kim, Y S; Park, J C

    1997-09-01

    In the early stage of the project, a comprehensive survey was conducted to identify the feasibility of using available facilities and of interface between those facilities. It was found out that the shielded cell M6 interface between those facilities. It was found out that the shielded cell M6 of IMEF could be used for the main process experiments of DUPIC fuel fabrication in regard to space adequacy, material flow, equipment layout, etc. Based on such examination, a suitable adapter system for material transfer around the M6 cell was engineered. Regarding the PIEF facility, where spent PWR fuel assemblies are stored in an annex pool, disassembly devices in the pool are retrofitted and spent fuel rod cutting and shipping system to the IMEF are designed and built. For acquisition of casks for radioactive material transport between the facilities, some adaptive refurbishment was applied to the available cask (Padirac) based on extensive analysis on safety requirements. A mockup test facility was newly acquired for remote test of DUPIC fuel fabrication process equipment prior to installation in the M6 cell of the IMEF facility. (author). 157 refs., 57 tabs., 65 figs.

  13. DUPIC facility engineering

    International Nuclear Information System (INIS)

    Lee, J. S.; Choi, J. W.; Go, W. I.; Kim, H. D.; Song, K. C.; Jeong, I. H.; Park, H. S.; Im, C. S.; Lee, H. M.; Moon, K. H.; Hong, K. P.; Lee, K. S.; Suh, K. S.; Kim, E. K.; Min, D. K.; Lee, J. C.; Chun, Y. B.; Paik, S. Y.; Lee, E. P.; Yoo, G. S.; Kim, Y. S.; Park, J. C.

    1997-09-01

    In the early stage of the project, a comprehensive survey was conducted to identify the feasibility of using available facilities and of interface between those facilities. It was found out that the shielded cell M6 interface between those facilities. It was found out that the shielded cell M6 of IMEF could be used for the main process experiments of DUPIC fuel fabrication in regard to space adequacy, material flow, equipment layout, etc. Based on such examination, a suitable adapter system for material transfer around the M6 cell was engineered. Regarding the PIEF facility, where spent PWR fuel assemblies are stored in an annex pool, disassembly devices in the pool are retrofitted and spent fuel rod cutting and shipping system to the IMEF are designed and built. For acquisition of casks for radioactive material transport between the facilities, some adaptive refurbishment was applied to the available cask (Padirac) based on extensive analysis on safety requirements. A mockup test facility was newly acquired for remote test of DUPIC fuel fabrication process equipment prior to installation in the M6 cell of the IMEF facility. (author). 157 refs., 57 tabs., 65 figs

  14. An ultrahigh-vacuum apparatus for resonant diffraction experiments using soft x rays (hν=300-2000 eV)

    International Nuclear Information System (INIS)

    Takeuchi, T.; Chainani, A.; Takata, Y.; Tanaka, Y.; Oura, M.; Tsubota, M.; Senba, Y.; Ohashi, H.; Mochiku, T.; Hirata, K.; Shin, S.

    2009-01-01

    We have developed an ultrahigh-vacuum instrument for resonant diffraction experiments using polarized soft x rays in the energy range of hν=300-2000 eV at beamline BL17SU of SPring-8. The diffractometer consists of modified differentially pumped rotary feedthroughs for θ-2θ stages, a sample manipulator with motor-controlled x-y-z-, tilt (χ)-, and azimuth (φ)-axes, and a liquid helium flow-type cryostat for temperature dependent measurements between 30 and 300 K. Test results indicate that the diffractometer exhibits high reproducibility (better than 0.001 deg.) for a Bragg reflection of α-quartz 100 at a photon energy of hν=1950 eV. Typical off- and on-resonance Bragg reflections in the energy range of 530-1950 eV could be measured using the apparatus. The results show that x-ray diffraction experiments with energy-, azimuth-, and incident photon polarization-dependence can be reliably measured using soft x rays in the energy range of ∼300-2000 eV. The facility can be used for resonant diffraction experiments across the L-edge of transition metals, M-edge of lanthanides, and up to the Si K-edge of materials.

  15. An automatic counting and recording system (1963); Ensemble de comptage a enregistrement automatique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-09-15

    An automatic control, counting and programing system for the collection of single crystal diffractometry data was designed by the author for a neutron diffractometer in 1958 at C.E.N - Grenoble. A part of the whole instrument, 'The Automatic Counting and Recording System', is described in this paper. Its applications are numerous and extensive, e.g.: the system has been designed for neutron diffractometer, but it can easily be adapted either for use with X-rays or measurement of mean life in {beta} decay analysis. (author) [French] Un ensemble automatique de telecommande, comptage et programmation pour la diffractometrie a cristal unique a ete etudie et realise par l'auteur pour la diffraction des neutrons en 1958 au C.E.N - Grenoble. Le present rapport decrit a ''l'Ensemble de Comptage a Enregistrement Automatique'' qui est une partie de l'appareillage complet. Ses applications sont nombreuses et peuvent s'etendre a de nouveaux domaines. En effet cet ensemble qui a ete etudie pour fonctionner avec un diffractometre a neutron, peut facilement s'adapter a la technique de diffraction des rayons X ou par exemple a celle de decroisasnce d'activite {beta}. (auteur)

  16. Health Facilities

    Science.gov (United States)

    Health facilities are places that provide health care. They include hospitals, clinics, outpatient care centers, and specialized care centers, ... psychiatric care centers. When you choose a health facility, you might want to consider How close it ...

  17. DUPIC facility engineering

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. J.; Lee, H. H.; Kim, K. H. and others

    2000-03-01

    The objectives of this study are (1) the refurbishment for PIEF(Post Irradiation Examination Facility) and M6 hot-cell in IMEF(Irradiated Material Examination Facility), (2) the establishment of the compatible facility for DUPIC fuel fabrication experiments which is licensed by government organization, and (3) the establishment of the transportation system and transportation cask for nuclear material between facilities. The report for this project describes following contents, such as objectives, necessities, scope, contents, results of current step, R and D plan in future and etc.

  18. Shielding of Medical Facilities. Shielding Design Considerations for PET-CT Facilities

    International Nuclear Information System (INIS)

    Cruzate, J.A.; Discacciatti, A.P.

    2011-01-01

    The radiological evaluation of a Positron Emission Tomography (PET) facility consists of the assessment of the annual effective dose both to workers occupationally exposed, and to members of the public. This assessment takes into account the radionuclides involved, the facility features, the working procedures, the expected number of patients per year, and so on. The evaluation embraces the distributions of rooms, the thickness and physical material of walls, floors and ceilings. This work detail the methodology used for making the assessment of a PET facility design taking into account only radioprotection aspects. The assessment results must be compared to the design requirements established by national regulations in order to determine whether or not, the facility complies with those requirements, both for workers and for members of the public. The analysis presented is useful for both, facility designers and regulators. In addition, some guidelines for improving the shielding design and working procedures are presented in order to help facility designer's job. (authors)

  19. Energy Systems Integration Facility (ESIF) Facility Stewardship Plan: Revision 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Juan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Anderson, Art [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-02

    The U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), has established the Energy Systems Integration Facility (ESIF) on the campus of the National Renewable Energy Laboratory (NREL) and has designated it as a DOE user facility. This 182,500-ft2 research facility provides state-of-the-art laboratory and support infrastructure to optimize the design and performance of electrical, thermal, fuel, and information technologies and systems at scale. This Facility Stewardship Plan provides DOE and other decision makers with information about the existing and expected capabilities of the ESIF and the expected performance metrics to be applied to ESIF operations. This plan is a living document that will be updated and refined throughout the lifetime of the facility.

  20. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2014-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot-single-crystal diffractometer HEiDi, the three-axis spectrometer PANDA, the backscattering spectrometer SPHERES, the DNS neutron-polarization analysis, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering at KWS-1 and KWS-2, a very-small-angle neutron scattering diffractometer with focusing mirror, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  1. Facilities Performance Indicators Report 2011-12: Tracking Your Facilities Vital Signs

    Science.gov (United States)

    APPA: Association of Higher Education Facilities Officers, 2013

    2013-01-01

    This paper provides an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. APPA's Information and Research Committee's goal for this year was to enhance the…

  2. Facility effluent monitoring plan for the tank farm facility

    Energy Technology Data Exchange (ETDEWEB)

    Crummel, G.M.

    1998-05-18

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements.

  3. Chemical composition of the semi-volatile grains of comet 67P/Churyumov-Gerasimenko

    Science.gov (United States)

    Wurz, Peter; Altwegg, Kathrin; Balsiger, Hans; Berthelier, Jean-Jacques; Bieler, André; Calmonte, Ursina; De Keyser, Johan; Fiethe, Björn; Fuselier, Stefan; Gasc, Sébastien; Gombosi, Tamas; Jäckel, Annette; Korth, Axel; Le Roy, Lena; Mall, Urs; Rème, Henri; Rubin, Martin; Tzou, Chia-Yu

    2017-04-01

    The European Space Agency's Rosetta spacecraft (Glassmeier et al., 2007) has been in orbit of the comet 67P/Churyumov-Gerasimenko (67P/C-G) since August 2014. On board is the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) instrument suite (Balsiger et al., 2007). ROSINA consists of two mass spectrometers, the Double Focusing Mass Spectrometer (DFMS) and the Reflectron-type Time-Of-Flight (RTOF) (Scherer et al., 2006), as well as the COmet Pressure Sensor (COPS). ROSINA is designed to detect and monitor the neutral gas and thermal plasma environment in the comet's coma by in situ investigation. The two mass spectrometers have high dynamic ranges and complement each other with high mass resolution (DFMS) and high time resolution and large mass range (RTOF). Especially the unprecedented sensitivity and mass resolution of DFMS together with the large mass range of RTOF allow determining precisely light species (e.g. isotopologues) as well as detecting heavy organic species. The pressure sensor COPS measures total gas densities, bulk velocities, and gas temperatures. ROSINA has been collecting data on the composition of the coma and activity of the comet from 3.5 AU to pericentre and out again to 3.5 AU. The Rosetta mission presents a unique opportunity to directly sample the parent species in the thin cometary atmosphere of a Kuiper-belt object at distances in excess of 2.5 AU from the Sun all the way to the pericentre of the cometary orbit at 1.24 AU. The ROSINA experiment continuously measured the chemical composition of the gases in the cometary coma. Occasionally, a dust grain of cometary origin enters the ion source of a ROSINA instrument where the volatile part evaporates since these ion sources are hot. We will report on the first measurements of the volatile inventory of such dust grains. Volatile release from cometary dust grains was observed with all three ROSINA instruments on several occasions. Because the volatile content of such a dust

  4. Instrument basics

    International Nuclear Information System (INIS)

    Jenkins, R.

    1999-01-01

    Full text: The earliest powder diffractometers date back to the mid-1930s when Le Galley described the use of a point source, line receiving slit, system. The modern parafocusing system was developed by Parrish et al, in the mid to late 1940s, and most diffractometers today employ this same parafocusing (Bragg-Brentano) geometry. With the arrival of the synchrotron more than a decade ago, many new innovations have come along, both in data collection and data processing. In addition, interest in thin film technology has spawned a new breed of diffractometer which used low glancing angle optics. However, as far as the average, stand-alone, diffractometer systems were concerned, the only real innovation has been along the line of addition of various types of monochromatization device, special types of proportional detector, automated slit systems, multi-sample handling devices and so on. This workshop reviews the optical arrangement of typical 'routine' diffractometers, and discusses the advantages and disadvantages of each. Copyright (1999) Australian X-ray Analytical Association Inc

  5. CLEAR test facility

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    A new user facility for accelerator R&D, the CERN Linear Electron Accelerator for Research (CLEAR), started operation in August 2017. CLEAR evolved from the former CLIC Test Facility 3 (CTF3) used by the Compact Linear Collider (CLIC). The new facility is able to host and test a broad range of ideas in the accelerator field.

  6. Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Ballinger, Marcel Y.; Gervais, Todd L.

    2004-11-15

    The Pacific Northwest National Laboratory (PNNL) operates a number of Research & Development (R&D) facilities for the U.S. Department of Energy (DOE) on the Hanford Site. Facility effluent monitoring plans (FEMPs) have been developed to document the facility effluent monitoring portion of the Environmental Monitoring Plan (DOE 2000) for the Hanford Site. Three of PNNL’s R&D facilities, the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling, and individual FEMPs were developed for these facilities in the past. In addition, a balance-of-plant (BOP) FEMP was developed for all other DOE-owned, PNNL-operated facilities at the Hanford Site. Recent changes, including shutdown of buildings and transition of PNNL facilities to the Office of Science, have resulted in retiring the 3720 FEMP and combining the 331 FEMP into the BOP FEMP. This version of the BOP FEMP addresses all DOE-owned, PNNL-operated facilities at the Hanford Site, excepting the Radiochemical Processing Laboratory, which has its own FEMP because of the unique nature of the building and operations. Activities in the BOP facilities range from administrative to laboratory and pilot-scale R&D. R&D activities include both radioactive and chemical waste characterization, fluid dynamics research, mechanical property testing, dosimetry research, and molecular sciences. The mission and activities for individual buildings are described in Appendix A. Potential radioactive airborne emissions in the BOP facilities are estimated annually using a building inventory-based approach provided in federal regulations. Sampling at individual BOP facilities is based on a potential-to-emit assessment. Some of these facilities are considered minor emission points and thus are sampled routinely, but not continuously, to confirm the low emission potential. One facility, the 331 Life Sciences Laboratory, has a major emission point and is sampled continuously. Sampling systems are

  7. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet Download

    Data.gov (United States)

    U.S. Environmental Protection Agency — This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are...

  8. Facility Effluent Monitoring Plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  9. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet Download

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in...

  10. Basic Research Firing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Basic Research Firing Facility is an indoor ballistic test facility that has recently transitioned from a customer-based facility to a dedicated basic research...

  11. A hard X-ray laboratory for monochromator characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamelin, B [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    Since their installation at ILL during the 1970`s the ILL {gamma}-ray diffractometers have been intensively used in the development of neutron monochromators. However, the ageing of the sources and new developments in hard X-ray diffractometry lead to a decision at the end of 1995 to replace the existing {gamma}-ray laboratory with a hard X-ray laboratory, based on a 420 keV generator, making available in the long term several beam-lines for rapid characterisation of monochromator crystals. The facility is now installed and its characteristics and advantages are outlined. (author). 2 refs.

  12. Facility effluent monitoring plan for the 300 Area Fuels Fabrication Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Brendel, D.F.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring system by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The Fuel Fabrication Facility in the Hanford 300 Area supported the production reactors from the 1940's until they were shut down in 1987. Prior to 1987 the Fuel Fabrication Facility released both airborne and liquid radioactive effluents. In January 1987 the emission of airborne radioactive effluents ceased with the shutdown of the fuels facility. The release of liquid radioactive effluents have continued although decreasing significantly from 1987 to 1990

  13. Trauma facilities in Denmark

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2018-01-01

    Background: Trauma is a leading cause of death among adults aged challenge. Evidence supports the centralization of trauma facilities and the use multidisciplinary trauma teams. Because knowledge is sparse on the existing distribution of trauma facilities...... and the organisation of trauma care in Denmark, the aim of this study was to identify all Danish facilities that care for traumatized patients and to investigate the diversity in organization of trauma management. Methods: We conducted a systematic observational cross-sectional study. First, all hospitals in Denmark...... were identified via online services and clarifying phone calls to each facility. Second, all trauma care manuals on all facilities that receive traumatized patients were gathered. Third, anesthesiologists and orthopedic surgeons on call at all trauma facilities were contacted via telephone...

  14. Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities

    International Nuclear Information System (INIS)

    Ballinger, M.Y.; Shields, K.D.

    1999-01-01

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) facilities. Activities in the BOP facilities range from administrative to laboratory and pilot-scale R and D. R and D activities include both radioactive and chemical waste characterization, fluid dynamics research, mechanical property testing, dosimetry research, and molecular sciences. The mission and activities for individual buildings are described in the FEMP

  15. Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Ballinger, M.Y.; Shields, K.D.

    1999-04-02

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) facilities. Activities in the BOP facilities range from administrative to laboratory and pilot-scale R and D. R and D activities include both radioactive and chemical waste characterization, fluid dynamics research, mechanical property testing, dosimetry research, and molecular sciences. The mission and activities for individual buildings are described in the FEMP.

  16. Facilities Programming.

    Science.gov (United States)

    Bullis, Robert V.

    1992-01-01

    A procedure for physical facilities management written 17 years ago is still worth following today. Each of the steps outlined for planning, organizing, directing, controlling, and evaluating must be accomplished if school facilities are to be properly planned and constructed. However, lessons have been learned about energy consumption and proper…

  17. Facility effluent monitoring plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Lavey, G.H.

    1992-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  18. High Throughput Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Argonne?s high throughput facility provides highly automated and parallel approaches to material and materials chemistry development. The facility allows scientists...

  19. Facility effluent monitoring plan for the tank farms facilities

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.; Kenoyer, J.L.; Moeller, M.P.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum three years. A variety of liquid wastes are generated in processing treatment, and disposal operations throughout the Hanford Site. The Tank Farms Project serves a major role in Hanford Site waste management activities as the temporary repository for these wastes. Stored wastes include hazardous components regulated under the Resource Conservation and Recovery Act of 1976 (RCRA) and as by-product material regulated under the Atomic Energy Act of 1954. A total of 177 single- and double-shell tanks (SST and DST) have been constructed in the 200 East and 200 West Areas of the Hanford Site. These facilities were constructed to various designs from 1943 to 1986. The Tank Farms Project is comprised of these tanks along with various transfer, receiving, and treatment facilities

  20. Test and User Facilities | NREL

    Science.gov (United States)

    Test and User Facilities Test and User Facilities Our test and user facilities are available to | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z B Battery Thermal and Life Test Facility Biochemical Conversion Pilot Plant C Controllable Grid Interface Test System D Dynamometer Test Facilities

  1. Licensed Healthcare Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Licensed Healthcare Facilities point layer represents the locations of all healthcare facilities licensed by the State of California, Department of Health...

  2. Facility effluent monitoring plan for the 324 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 324 Facility [Waste Technology Engineering Laboratory] in the 300 Area primarily supports the research and development of radioactive and nonradioactive waste vitrification technologies, biological waste remediation technologies, spent nuclear fuel studies, waste mixing and transport studies, and tritium development programs. All of the above-mentioned programs deal with, and have the potential to, release hazardous and/or radioactive material. The potential for discharge would primarily result from (1) conducting research activities using the hazardous materials, (2) storing radionuclides and hazardous chemicals, and (3) waste accumulation and storage. This report summarizes the airborne and liquid effluents, and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterizing effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  3. Outline of NUCEF facility

    International Nuclear Information System (INIS)

    Takeshita, Isao

    1996-01-01

    NUCEF is a multipurpose research facility in the field of safety and advanced technology of nuclear fuel cycle back-end. Various experiment facilities and its supporting installations, in which nuclear fuel materials, radio isotopes and TRU elements can be handled, are arranged in more than one hundred rooms of two experiment buildings. Its construction was completed in middle of 1994 and hot experiments have been started since then. NUCEF is located on the site (30,000 m 2 ) of southeastern part in the Tokai Research Establishment of JAERI facing to the Pacific Ocean. The base of Experiment Buildings A and B was directly founded on the rock existing at 10-15 m below ground level taking the aseismatic design into consideration. Each building is almost same sized and composed of one basement and three floors of which area is 17,500 m 2 in total. In the basement, there are exhaust facilities of ventilation system, treatment system of solution fuel and radioactive waste solution and storage tanks of them. Major experiment facilities are located on the first or the second floors in each building. An air-inlet facility of ventilation system for each building is equipped on the third floor. Most of experiment facilities for criticality safety research including two critical facilities: Static Experiment Critical Facility (STACY) and Transient Experiment Critical Facility (TRACY) are installed in Experiment Building A. Experiment equipments for research on advanced fuel reprocessing process and on TRU waste management, which are named BECKY (Back End Fuel Cycle Key Elements Research Facility), are installed in laboratories and a-g cells in Experiment Building B. (J.P.N.)

  4. Rocketball Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This test facility offers the capability to emulate and measure guided missile radar cross-section without requiring flight tests of tactical missiles. This facility...

  5. Facility Description 2012. Summary report of the encapsulation plant and disposal facility designs

    International Nuclear Information System (INIS)

    Palomaeki, J.; Ristimaeki, L.

    2013-10-01

    The purpose of the facility description is to be a specific summary report of the scope of Posiva's nuclear facilities (encapsulation plant and disposal facility) in Olkiluoto. This facility description is based on the 2012 designs and completing Posiva working reports. The facility description depicts the nuclear facilities and their operation as the disposal of spent nuclear fuel starts in Olkiluoto in about 2020. According to the decisions-in-principle of the government, the spent nuclear fuel from Loviisa and Olkiluoto nuclear power plants in operation and in future cumulative spent nuclear fuel from Loviisa 1 and 2, Olkiluoto 1, 2, 3 and 4 nuclear power plants, is permitted to be disposed of in Olkiluoto bedrock. The design of the disposal facility is based on the KBS-3V concept (vertical disposal). Long-term safety concept is based on the multi-barrier principle i.e. several release barriers, which ensure one another so that insufficiency in the performance of one barrier doesn't jeopardize long-term safety of the disposal. The release barriers are the following: canister, bentonite buffer and deposition tunnel backfill, and the host rock around the repository. The canisters are installed into the deposition holes, which are bored to the floor of the deposition tunnels. The canisters are enveloped with compacted bentonite blocks, which swell after absorbing water. The surrounding bedrock and the central and access tunnel backfill provide additional retardation, retention, and dilution. The nuclear facilities consist of an encapsulation plant and of underground final disposal facility including other aboveground buildings and surface structures serving the facility. The access tunnel and ventilation shafts to the underground disposal facility and some auxiliary rooms are constructed as a part of ONKALO underground rock characterization facility during years 2004-2014. The construction works needed for the repository start after obtaining the construction

  6. 340 Facility compliance assessment

    International Nuclear Information System (INIS)

    English, S.L.

    1993-10-01

    This study provides an environmental compliance evaluation of the RLWS and the RPS systems of the 340 Facility. The emphasis of the evaluation centers on compliance with WAC requirements for hazardous and mixed waste facilities, federal regulations, and Westinghouse Hanford Company (WHC) requirements pertinent to the operation of the 340 Facility. The 340 Facility is not covered under either an interim status Part A permit or a RCRA Part B permit. The detailed discussion of compliance deficiencies are summarized in Section 2.0. This includes items of significance that require action to ensure facility compliance with WAC, federal regulations, and WHC requirements. Outstanding issues exist for radioactive airborne effluent sampling and monitoring, radioactive liquid effluent sampling and monitoring, non-radioactive liquid effluent sampling and monitoring, less than 90 day waste storage tanks, and requirements for a permitted facility

  7. Wastewater Treatment Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Individual permits for municipal, industrial, and semi-public wastewater treatment facilities in Iowa for the National Pollutant Discharge Elimination System (NPDES)...

  8. Energetics Conditioning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Conditioning Facility is used for long term and short term aging studies of energetic materials. The facility has 10 conditioning chambers of which 2...

  9. Facilities projects performance measurement system

    International Nuclear Information System (INIS)

    Erben, J.F.

    1979-01-01

    The two DOE-owned facilities at Hanford, the Fuels and Materials Examination Facility (FMEF), and the Fusion Materials Irradiation Test Facility (FMIT), are described. The performance measurement systems used at these two facilities are next described

  10. Explosive Components Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The 98,000 square foot Explosive Components Facility (ECF) is a state-of-the-art facility that provides a full-range of chemical, material, and performance analysis...

  11. Design of the PRIDE Facility

    International Nuclear Information System (INIS)

    You, Gil Sung; Choung, Won Myung; Lee, Eun Pyo; Cho, Il Je; Kwon, Kie Chan; Hong, Dong Hee; Lee, Won Kyung; Ku, Jeong Hoe

    2009-01-01

    From 2007, KAERI is developing a PyRoprocess Integrated inactive DEmonstration facility (the PRIDE facility). The maximum annual treatment capacity of this facility will be a 10 ton-HM. The process will use a natural uranium feed material or a natural uranium mixed with some surrogate material for a simulation of a spent fuel. KAERI has also another plan to construct a demonstration facility which can treat a real spent fuel by pyroprocessing. This facility is called by ESPF, Engineering Scale Pyroprocess Facility. The ESPF will have the same treatment capability of spent fuel with the PRIDE facility. The only difference between the PRIDE and the ESPF is a radiation shielding capability. From the PRIDE facility designing works and demonstration with a simulated spent fuel after construction, it will be able to obtain the basic facility requirements, remote operability, interrelation properties between process equipment for designing of the ESPF. The flow sheet of the PRIDE processes is composed of five main processes, such as a decladding and voloxidation, an electro-reduction, an electrorefining, an electro-winning, and a salt waste treatment. The final products from the PRIDE facility are a simulated TRU metal and U metal ingot

  12. Comprehensive facilities plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    The Ernest Orlando Lawrence Berkeley National Laboratory`s Comprehensive Facilities Plan (CFP) document provides analysis and policy guidance for the effective use and orderly future development of land and capital assets at the Berkeley Lab site. The CFP directly supports Berkeley Lab`s role as a multiprogram national laboratory operated by the University of California (UC) for the Department of Energy (DOE). The CFP is revised annually on Berkeley Lab`s Facilities Planning Website. Major revisions are consistent with DOE policy and review guidance. Facilities planing is motivated by the need to develop facilities for DOE programmatic needs; to maintain, replace and rehabilitate existing obsolete facilities; to identify sites for anticipated programmatic growth; and to establish a planning framework in recognition of site amenities and the surrounding community. The CFP presents a concise expression of the policy for the future physical development of the Laboratory, based upon anticipated operational needs of research programs and the environmental setting. It is a product of the ongoing planning processes and is a dynamic information source.

  13. Conceptual design report, Sodium Storage Facility, Fast Flux Test Facility, Project F-031

    International Nuclear Information System (INIS)

    Shank, D.R.

    1995-01-01

    The Sodium Storage Facility Conceptual Design Report provides conceptual design for construction of a new facility for storage of the 260,000 gallons of sodium presently in the FFTF plant. The facility will accept the molten sodium transferred from the FFTF sodium systems, and store the sodium in a solid state under an inert cover gas until such time as a Sodium Reaction Facility is available for final disposal of the sodium

  14. Dialysis Facility Compare

    Data.gov (United States)

    U.S. Department of Health & Human Services — Dialysis Facility Compare helps you find detailed information about Medicare-certified dialysis facilities. You can compare the services and the quality of care that...

  15. Projectile Demilitarization Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Projectile Wash Out Facility is US Army Ammunition Peculiar Equipment (APE 1300). It is a pilot scale wash out facility that uses high pressure water and steam...

  16. Facility design: introduction

    International Nuclear Information System (INIS)

    Unger, W.E.

    1980-01-01

    The design of shielded chemical processing facilities for handling plutonium is discussed. The TRU facility is considered in particular; its features for minimizing the escape of process materials are listed. 20 figures

  17. Status of RIB facilities in Asia

    International Nuclear Information System (INIS)

    Tanihata, Isao

    1998-01-01

    Radioactive Ion Beam Facilities in Asia are presented. In China, in-flight separation type facilities are in operation at the Institute of Modern Physics in Lanzhou and the other at Tandem facility in China Institute of Atomic Energy in Beijing. The storage-ring facility is proposed and approved in Lanzhou. In India, the Variable Energy Cyclotron Facility in Calcutta start to construct an ISOL-type facility. In Japan, in-flight separation type facilities are working at Research Center for Nuclear Physics in Osaka, and at RIKEN. Also a separator start its operation in medical facility in Chiba. In RIKEN, the construction of RI Beam Factory has been started. An ISOL-type facility is proposed in the Japan Hadron Facility in KEK. Table I summarize these facilities

  18. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  19. Facility effluent monitoring plan for the plutonium uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  20. Facility effluent monitoring plan for the plutonium uranium extraction facility

    International Nuclear Information System (INIS)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  1. Facility effluent monitoring plan for the Plutonium Uranium Extraction Facility

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan will ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, at a minimum, every 3 years

  2. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Lohrasbi, J.; Johnson, D.L. [Westinghouse Hanford Co., Richland, WA (United States); De Lorenzo, D.S. [Los Alamos Technical Associates, NM (United States)

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  3. Current status of neutron scattering in Thailand

    International Nuclear Information System (INIS)

    Kornduangkaeo, Areeratt; Pongkasem, Somchai; Putchar, Suriya; Ampornrat, Pantip; Kajornrith, Varavuth; Sangariyavanich, Archara

    2003-01-01

    The current neutron powder diffractometer at the Thai Research Reactor-1/M1 (TRR-1/M1) has been modified from the obsolete neutron diffractometer which had been used during 1968-1975. The upgraded diffractometer has medium resolution and is appropriate for studying samples with small unit cell dimensions and training university students in the field of neutron scattering. This paper describes the current activities of neutron scattering research in Thailand as well as a new research reactor for enlarging the perspectives of its utilization in the future. (author)

  4. Neutron scattering. Experiment manuals

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  5. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  6. The development of automatic neutron diffractometry at Harwell

    International Nuclear Information System (INIS)

    Hall, J.W.

    1978-08-01

    Neutron diffractometry contributes substantially to studies of the structure of materials. Scientists at Harwell were among the first to make the collection of diffractometer data automatic and have continued to contribute to this field. This paper outlines the development of automatic neutron diffractometers at Harwell from 1960, and considers the various ANDROMACHE systems up to a hierarchical computer system that is anticipated for 1979. Appendices provide examples of the documentation provided for users of the ANDROMACHE Mark 6 neutron diffractometer system and give brief descriptions of the elements of the programs. (author)

  7. Integrated Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the center of the 586-square-mile Hanford Site is the Integrated Disposal Facility, also known as the IDF.This facility is a landfill similar in concept...

  8. STAR facility tritium accountancy

    International Nuclear Information System (INIS)

    Pawelko, R. J.; Sharpe, J. P.; Denny, B. J.

    2008-01-01

    The Safety and Tritium Applied Research (STAR) facility has been established to provide a laboratory infrastructure for the fusion community to study tritium science associated with the development of safe fusion energy and other technologies. STAR is a radiological facility with an administrative total tritium inventory limit of 1.5 g (14,429 Ci) [1]. Research studies with moderate tritium quantities and various radionuclides are performed in STAR. Successful operation of the STAR facility requires the ability to receive, inventory, store, dispense tritium to experiments, and to dispose of tritiated waste while accurately monitoring the tritium inventory in the facility. This paper describes tritium accountancy in the STAR facility. A primary accountancy instrument is the tritium Storage and Assay System (SAS): a system designed to receive, assay, store, and dispense tritium to experiments. Presented are the methods used to calibrate and operate the SAS. Accountancy processes utilizing the Tritium Cleanup System (TCS), and the Stack Tritium Monitoring System (STMS) are also discussed. Also presented are the equations used to quantify the amount of tritium being received into the facility, transferred to experiments, and removed from the facility. Finally, the STAR tritium accountability database is discussed. (authors)

  9. Synchrotron radiation facilities

    CERN Multimedia

    1972-01-01

    Particularly in the past few years, interest in using the synchrotron radiation emanating from high energy, circular electron machines has grown considerably. In our February issue we included an article on the synchrotron radiation facility at Frascati. This month we are spreading the net wider — saying something about the properties of the radiation, listing the centres where synchrotron radiation facilities exist, adding a brief description of three of them and mentioning areas of physics in which the facilities are used.

  10. The CUTLASS database facilities

    International Nuclear Information System (INIS)

    Jervis, P.; Rutter, P.

    1988-09-01

    The enhancement of the CUTLASS database management system to provide improved facilities for data handling is seen as a prerequisite to its effective use for future power station data processing and control applications. This particularly applies to the larger projects such as AGR data processing system refurbishments, and the data processing systems required for the new Coal Fired Reference Design stations. In anticipation of the need for improved data handling facilities in CUTLASS, the CEGB established a User Sub-Group in the early 1980's to define the database facilities required by users. Following the endorsement of the resulting specification and a detailed design study, the database facilities have been implemented as an integral part of the CUTLASS system. This paper provides an introduction to the range of CUTLASS Database facilities, and emphasises the role of Database as the central facility around which future Kit 1 and (particularly) Kit 6 CUTLASS based data processing and control systems will be designed and implemented. (author)

  11. ILL. Annual report 1979

    International Nuclear Information System (INIS)

    1980-01-01

    The reactor worked well during 1979, a total of 260 days being available out of the possible maximum of 264. Two new instruments (IN12 and D18) and one completely rebuilt instrument (D10) came into operation during 1979. In addition, the construction of the instruments IN6, IN13, D19, IN1*, D4* and D1B was continued. Detailed designs were made, and construction should begin soon on the pre-project for the fission product spectrometer and the supermirror polarisation analyser for the diffuse scattering spectrometer. Development projects include the reconstruction of D16 for high resolution, large unit cell, biological single crystal diffraction experiments, the H11 project to produce three instruments, an extremely high intensity powder diffractometer, a very high resolution powder diffractometer, and a multidetector single crystal diffractometer. A noticeable improvement in the data treatment facilities at the time-of-flight, diffraction and nuclear physics instruments has been produced through a major effort during 1979 to allow better control of an experiment whilst it is in progress. Strong emphasis was again given in 1979 to the development of new neutron techniques. The supermirror evaporator (S3) began to work under completely automatic computer control in October and produced the first batch of supermirrors. Regular production is now assured and systematic experimentation to improve the mirror characteristics is underway. Again in the field of neutron techniques, the decision has been made to construct the external ultra cold neutron source relying upon liquid 4 He at 0.7 0 K to produce high densities of ultra cold neutrons in a confined space. The project to replace the present cold source by one with improved performance has gone to the construction stage

  12. Materiel Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — CRREL's Materiel Evaluation Facility (MEF) is a large cold-room facility that can be set up at temperatures ranging from −20°F to 120°F with a temperature change...

  13. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontage, S.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years

  14. AOV Facility Tool/Facility Safety Specifications -

    Data.gov (United States)

    Department of Transportation — Develop and maintain authorizing documents that are standards that facilities must follow. These standards are references of FAA regulations and are specific to the...

  15. 202-S Hexone Facility supplemental information to the Hanford Facility Contingency Plan

    International Nuclear Information System (INIS)

    Ingle, S.J.

    1996-03-01

    This document is a unit-specific contingency plan for the 202-S Hexone Facility and is intended to be used as a supplement to the Hanford Facility Contingency Plan. This unit-specific plan is to be used to demonstrate compliance with the contingency plan requirements of WAC 173-303 for certain Resource Conservation and Recovery Act of 1976 (RCRA) waste management units. The 202-S Hexone Facility is not used to process radioactive or nonradioactive hazardous material. Radioactive, dangerous waste material is contained in two underground storage tanks, 276-S-141 and 276-S-142. These tanks do not present a significant hazard to adjacent facilities, personnel, or the environment. Currently, dangerous waste management activities are not being applied at the tanks. It is unlikely that any incidents presenting hazards to public health or the environment would occur at the 202-S Hexone Facility

  16. 9 CFR 351.10 - Facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Facilities. 351.10 Section 351.10... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be...

  17. Surplus Facilities Management Program

    International Nuclear Information System (INIS)

    Coobs, J.H.

    1983-01-01

    This is the second of two programs that are concerned with the management of surplus facilities. The facilities in this program are those related to commercial activities, which include the three surplus experimental and test reactors [(MSRE, HRE-2, and the Low Intensity Test Reactor (LITR)] and seven experimental loops at the ORR. The program is an integral part of the Surplus Facilities Management Program, which is a national program administered for DOE by the Richland Operations Office. Very briefly reported here are routine surveillance and maintenance of surplus radioactively contaminated DOE facilities awaiting decommissioning

  18. The National Ignition Facility (NIF) as a User Facility

    Science.gov (United States)

    Keane, Christopher; NIF Team

    2013-10-01

    The National Ignition Facility (NIF) has made significant progress towards operation as a user facility. Through June 2013, NIF conducted over 1200 experiments in support of ICF, HED science, and development of facility capabilities. The NIF laser has met or achieved all specifications and a wide variety of diagnostic and target fabrication capabilities are in place. A NIF User Group and associated Executive Board have been formed. Two User Group meetings have been conducted since formation of the User Group. NIF experiments in fundamental science have provided important new results. NIF ramp compression experiments have been conducted using diamond and iron, with EOS results obtained at pressures up to approximately 50 Mbar and 8 Mbar, respectively. Initial experiments in supernova hydrodynamics, the fundamental physics of the Rayleigh-Taylor instability, and equation of state in the Gbar pressure regime have also been conducted. This presentation will discuss the fundamental science program at NIF, including the proposal solicitation and scientific review processes and other aspects of user facility operation. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.

  19. Challenges for proteomics core facilities.

    Science.gov (United States)

    Lilley, Kathryn S; Deery, Michael J; Gatto, Laurent

    2011-03-01

    Many analytical techniques have been executed by core facilities established within academic, pharmaceutical and other industrial institutions. The centralization of such facilities ensures a level of expertise and hardware which often cannot be supported by individual laboratories. The establishment of a core facility thus makes the technology available for multiple researchers in the same institution. Often, the services within the core facility are also opened out to researchers from other institutions, frequently with a fee being levied for the service provided. In the 1990s, with the onset of the age of genomics, there was an abundance of DNA analysis facilities, many of which have since disappeared from institutions and are now available through commercial sources. Ten years on, as proteomics was beginning to be utilized by many researchers, this technology found itself an ideal candidate for being placed within a core facility. We discuss what in our view are the daily challenges of proteomics core facilities. We also examine the potential unmet needs of the proteomics core facility that may also be applicable to proteomics laboratories which do not function as core facilities. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. 7 CFR 58.127 - Facilities.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Facilities. 58.127 Section 58.127 Agriculture..., Facilities, Equipment and Utensils § 58.127 Facilities. (a) Water supply. There shall be an ample supply of both hot and cold water of safe and sanitary quality, with adequate facilities for its proper...

  1. Sustainable Facilities Management

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Elle, Morten; Hoffmann, Birgitte

    2004-01-01

    The Danish public housing sector has more than 20 years of experience with sustainable facilities management based on user involvement. The paper outlines this development in a historical perspective and gives an analysis of different approaches to sustainable facilities management. The focus...... is on the housing departments and strateies for the management of the use of resources. The research methods used are case studies based on interviews in addition to literature studies. The paper explores lessons to be learned about sustainable facilities management in general, and points to a need for new...

  2. Wind Energy Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, Carol

    2017-02-01

    This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.

  3. Facility effluent monitoring plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontag, S.

    1991-11-01

    A facility effluent monitoring plant is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The UO 3 Plant is located in the south-central portion of the 200 West Area of the Hanford Site. The plant consists of two primary processing buildings and several ancillary facilities. The purpose of the UO 3 Plant is to receive uranyl nitrate hexahydrate (UNH) from the Plutonium-Uranium Extraction (PUREX) Plant, concentrate it, convert the UNH to uranium trioxide (UO 3 ) powder by calcination and package it for offsite shipment. The UO 3 Plant has been placed in a standby mode. There are two liquid discharges, and three gaseous exhaust stacks, and seven building exhausters that are active during standby conditions

  4. Nuclear physics accelerator facilities

    International Nuclear Information System (INIS)

    1988-12-01

    This paper describes many of the nuclear physics heavy-ion accelerator facilities in the US and the research programs being conducted. The accelerators described are: Argonne National Laboratory--ATLAS; Brookhaven National Laboratory--Tandem/AGS Heavy Ion Facility; Brookhaven National Laboratory--Relativistic Heavy Ion Collider (RHIC) (Proposed); Continuous Electron Beam Accelerator Facility; Lawrence Berkeley Laboratory--Bevalac; Lawrence Berkeley Laboratory--88-Inch Cyclotron; Los Alamos National Laboratory--Clinton P. Anderson Meson Physics Facility (LAMPF); Massachusetts Institute of Technology--Bates Linear Accelerator Center; Oak Ridge National Laboratory--Holifield Heavy Ion Research Facility; Oak Ridge National Laboratory--Oak Ridge Electron Linear Accelerator; Stanford Linear Accelerator Center--Nuclear Physics Injector; Texas AandM University--Texas AandM Cyclotron; Triangle Universities Nuclear Laboratory (TUNL); University of Washington--Tandem/Superconducting Booster; and Yale University--Tandem Van de Graaff

  5. An automatic counting and recording system (1963); Ensemble de comptage a enregistrement automatique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, B. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-09-15

    An automatic control, counting and programing system for the collection of single crystal diffractometry data was designed by the author for a neutron diffractometer in 1958 at C.E.N - Grenoble. A part of the whole instrument, 'The Automatic Counting and Recording System', is described in this paper. Its applications are numerous and extensive, e.g.: the system has been designed for neutron diffractometer, but it can easily be adapted either for use with X-rays or measurement of mean life in {beta} decay analysis. (author) [French] Un ensemble automatique de telecommande, comptage et programmation pour la diffractometrie a cristal unique a ete etudie et realise par l'auteur pour la diffraction des neutrons en 1958 au C.E.N - Grenoble. Le present rapport decrit a ''l'Ensemble de Comptage a Enregistrement Automatique'' qui est une partie de l'appareillage complet. Ses applications sont nombreuses et peuvent s'etendre a de nouveaux domaines. En effet cet ensemble qui a ete etudie pour fonctionner avec un diffractometre a neutron, peut facilement s'adapter a la technique de diffraction des rayons X ou par exemple a celle de decroisasnce d'activite {beta}. (auteur)

  6. National Ignition Facility system design requirements conventional facilities SDR001

    International Nuclear Information System (INIS)

    Hands, J.

    1996-01-01

    This System Design Requirements (SDR) document specifies the functions to be performed and the minimum design requirements for the National Ignition Facility (NIF) site infrastructure and conventional facilities. These consist of the physical site and buildings necessary to house the laser, target chamber, target preparation areas, optics support and ancillary functions

  7. Irradiation facilities in JRR-3M

    International Nuclear Information System (INIS)

    Ohtomo, Akitoshi; Sigemoto, Masamitsu; Takahashi, Hidetake

    1992-01-01

    Irradiation facilities have been installed in the upgraded JRR-3 (JRR-3M) in Japan Atomic Energy Research Institute (JAERI). There are hydraulic rabbit facilities (HR), pneumatic rabbit facilities (PN), neutron activation analysis facility (PN3), uniform irradiation facility (SI), rotating irradiation facility and capsule irradiation facilities to carry out the neutron irradiation in the JRR-3M. These facilities are operated using a process control computer system to centerize the process information. Some of the characteristics for the facilities were satisfactorily measured at the same time of reactor performance test in 1990. During reactor operation, some of the tests are continued to confirm the basic characteristics on facilities, for example, PN3 was confirmed to have enough performance for activation analysis. Measurement of neutron flux at all irradiation positions has been carried out for the equilibrium core. (author)

  8. Facility effluent monitoring plan for the tank farms facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, D.D.; Crummel, G.M.

    1995-05-01

    A facility effluent monitoring plan is required by the US Department of Energy for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using specific guidelines. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years.

  9. 21 CFR 606.40 - Facilities.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Facilities. 606.40 Section 606.40 Food and Drugs... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Plant and Facilities § 606.40 Facilities. Facilities shall be maintained in a clean and orderly manner, and shall be of suitable size, construction and...

  10. Hanford Surplus Facilities Program plan

    International Nuclear Information System (INIS)

    Hughes, M.C.; Wahlen, R.K.; Winship, R.A.

    1989-09-01

    The Hanford Surplus Facilities Program is responsible for the safe and cost-effective surveillance, maintenance, and decommissioning of surplus facilities at the Hanford Site. The management of these facilities requires a surveillance and maintenance program to keep them in a safe condition and development of a plan for ultimate disposition. Criteria used to evaluate each factor relative to decommissioning are based on the guidelines presented by the US Department of Energy-Richland Operations Office, Defense Facilities Decommissioning Program Office, and are consistent with the Westinghouse Hanford Company commitment to decommission the Hanford Site retired facilities in the safest and most cost-effective way achievable. This document outlines the plan for managing these facilities to the end of disposition

  11. Green facility location

    NARCIS (Netherlands)

    Velázquez Martínez, J.C.; Fransoo, J.C.; Bouchery, Y.; Corbett, C.J.; Fransoo, J.C.; Tan, T.

    2017-01-01

    Transportation is one of the main contributing factors of global carbon emissions, and thus, when dealing with facility location models in a distribution context, transportation emissions may be substantially higher than the emissions due to production or storage. Because facility location models

  12. Requirements of on-site facilities

    International Nuclear Information System (INIS)

    Burchardt, H.

    1977-01-01

    1) Requirements of on-site facilities: a) brief description of supplying the site with electricity and water; communication facilities, b) necessary facilities for containment and pipeline installation, c) necessary facilities for storage, safety, accommodation of personnel, housing; workshops; 2) Site management: a) Organisation schedules for 'turn-key-jobs' and 'single commission', b) Duties of the supervisory staff. (orig.) [de

  13. 304 Concretion facility closure plan

    International Nuclear Information System (INIS)

    1990-04-01

    The Hanford Site, located northwest of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. Recyclable scrap uranium Zircaloy-2 and copper silicon alloy, uranium-titanium alloy, beryllium/Zircaloy-2 alloy, and Zircaloy-2 chips and fines were secured in concrete billets in the 304 Concretion Facility, located in the 300 Area. The beryllium/Zircaloy-2 alloy and Zircaloy-2 chips and fines are designated as low-level radioactive mixed waste (LLRMW) with the characteristic of ignitability. The concretion process reduced the ignitability of the fines and chips for safe storage and shipment. This process has been discontinued and the 304 Concretion Facility is now undergoing closure as defined in the Resource Conservation and Recovery Act of 1976 (RCRA). This closure plan presents a description of the facility, the history of materials and wastes managed, and the procedures that will be followed to close the 304 Concretion Facility (304 Facility). Clean closure of the 304 Facility is the proposed method for closure of the facility. Justification for this proposal is presented. 15 refs., 22 figs., 4 tabs

  14. Decommissioning nuclear facilities

    International Nuclear Information System (INIS)

    Harmon, K.M.; Jenkins, C.E.; Waite, D.A.; Brooksbank, R.E.; Lunis, B.C.; Nemec, J.F.

    1976-01-01

    This paper describes the currently accepted alternatives for decommissioning retired light water reactor fuel cycle facilities and the current state of decommissioning technology. Three alternatives are recognized: Protective Storage; Entombment; and Dismantling. Application of these alternatives to the following types of facilities is briefly described: light water reactors; fuel reprocessing plants, and mixed oxide fuel fabrication plants. Brief descriptions are given of decommissioning operations and results at a number of sites, and recent studies of the future decommissioning of prototype fuel cycle facilities are reviewed. An overview is provided of the types of operations performed and tools used in common decontamination and decommissioning techniques and needs for improved technology are suggested. Planning for decommissioning a nuclear facility is dependent upon the maximum permitted levels of residual radioactive contamination. Proposed guides and recently developed methodology for development of site release criteria are reviewed. 21 fig, 32 references

  15. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  16. Associations between Moderate-to-Vigorous Physical Activity and Neighbourhood Recreational Facilities: The Features of the Facilities Matter

    Directory of Open Access Journals (Sweden)

    Ka Yiu Lee

    2014-12-01

    Full Text Available Objectives: To examine the associations between objectively-assessed moderate-to-vigorous physical activity (MVPA and perceived/objective measures of neighbourhood recreational facilities categorized into indoor or outdoor, public, residential or commercial facilities. The associations between facility perceptions and objectively-assessed numbers of recreational facilities were also examined. Method: A questionnaire was used on 480 adults to measure local facility perceptions, with 154 participants wearing ActiGraph accelerometers for ≥4 days. The objectively-assessed number of neighbourhood recreational facilities were examined using direct observations and Geographical Information System data. Results: Both positive and negative associations were found between MVPA and perceived/objective measures of recreational facilities. Some associations depended on whether the recreational facilities were indoor or outdoor, public or residential facilities. The objectively-assessed number of most public recreational facilities was associated with the corresponding facility perceptions, but the size of effect was generally lower than for residential recreational facilities. Conclusions: The objectively-assessed number of residential outdoor table tennis courts and public indoor swimming pools, the objectively-assessed presence of tennis courts and swimming pools, and the perceived presence of bike lanes and swimming pools were positive determinants of MVPA. It is suggested to categorize the recreational facilities into smaller divisions in order to identify unique associations with MVPA.

  17. WORKSHOPS: Hadron facilities

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    'Hadron facilities' – high intensity (typically a hundred microamps), medium energy (30-60 GeV) machines producing intense secondary beams of pions, kaons, etc., are being widely touted as a profitable research avenue to supplement what is learned through the thrust for higher and higher energies. This interest was reflected at an International Workshop on Hadron Facility Technology, held in Santa Fe, New Mexico. As well as invited talks describing the various projects being pushed in the US, Europe and Japan, the meeting included working groups covering linacs, beam dynamics, hardware, radiofrequency, polarized beams and experimental facilities

  18. Investigating walking environments in and around assisted living facilities: a facility visit study.

    Science.gov (United States)

    Lu, Zhipeng

    2010-01-01

    This study explores assisted living residents' walking behaviors, locations where residents prefer to walk, and walking environments in and around assisted living facilities. Regular walking is beneficial to older adults' physical and psychological health. Yet frail older residents in assisted living are usually too sedentary to achieve these benefits. The physical environment plays an important role in promoting physical activity. However, there is little research exploring this relationship in assisted living settings. The researcher visited 34 assisted living facilities in a major Texas city. Methods included walk-through observation with the Assisted Living Facility Walking Environment Checklist, and interviews with administrators by open- and close-ended questions. The data from 26 facilities were analyzed using descriptive statistics (for quantitative data) and content analysis (for qualitative data). The results indicate that (a) residents were walking both indoors and outdoors for exercise or other purposes (e.g., going to destinations); (b) assisted living facility planning and design details-such as neighborhood sidewalk conditions, facility site selection, availability of seating, walking path configuration (e.g., looped/nonlooped path), amount of shading along the path, presence of handrails, existence of signage, etc.-may influence residents' walking behaviors; and (c) current assisted living facilities need improvement in all aspects to make their environments more walkable for residents. Findings of the study provide recommendations for assisted living facilities to improve the walkability of environments and to create environmental interventions to promote regular walking among their residents. This study also implies several directions for future research.

  19. Waste isolation facility description: bedded salt

    Energy Technology Data Exchange (ETDEWEB)

    1976-09-01

    The waste isolation facility is designed to receive and store three basic types of solidified wastes: high-level wastes, intermediate level high-gamma transuranic waste, and low-gamma transuranic wastes. The facility under consideration in this report is designed for bedded salt at a depth of approximately 1800 ft. The present design for the facility includes an area which would be used initially as a pilot facility to test the viability of the concept, and a larger facility which would constitute the final storage area. The total storage area in the pilot facility is planned to be 77 acres and in the fuel facility 1601 acres. Other areas for shaft operations and access would raise the overall size of the total facility to slightly less than 2,000 acres. The following subjects are discussed in detail: surface facilities, shaft design and characteristics, design and construction of the underground waste isolation facility, ventilation systems, and design requirements and criteria. (LK)

  20. Waste isolation facility description: bedded salt

    International Nuclear Information System (INIS)

    1976-09-01

    The waste isolation facility is designed to receive and store three basic types of solidified wastes: high-level wastes, intermediate level high-gamma transuranic waste, and low-gamma transuranic wastes. The facility under consideration in this report is designed for bedded salt at a depth of approximately 1800 ft. The present design for the facility includes an area which would be used initially as a pilot facility to test the viability of the concept, and a larger facility which would constitute the final storage area. The total storage area in the pilot facility is planned to be 77 acres and in the fuel facility 1601 acres. Other areas for shaft operations and access would raise the overall size of the total facility to slightly less than 2,000 acres. The following subjects are discussed in detail: surface facilities, shaft design and characteristics, design and construction of the underground waste isolation facility, ventilation systems, and design requirements and criteria

  1. Investigation on candidates of principal facilities for exposure dose to public for the facilities using nuclear material

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Sawahata, Hiroaki; Takada, Shoji; Fujimoto, Nozomu

    2015-01-01

    HTTR holds the nuclear fuel material use facilities in its reactor facilities, for the purpose of study on the fracture behavior of fuel and release behavior of fission products, development of high-performance fuel, and measurement of neutron flux. Due to the revision of the 'Act on the regulation of nuclear source material, nuclear fuel material and reactor', the facilities having the 'Important safety-related facilities' among the facilities applicable to the Enforcement Ordinance Article 41 (Article 41 facilities) has come to need to conform to the 'Regulations concerning standards for the location, structure, and equipment of used facilities and others'. In this case, actions such as modification by all possible means are required. The nuclear fuel substance use facilities of HTTR correspond to Article 41 facilities. So, whether it is a candidate for the 'Important safety-related facilities' has been examined. As a result, it is confirmed that the facilities are not correspond to the 'Important safety-related facilities', and it has been concluded that modification measures for the purpose of conforming to this approval standard rule are not necessary as of the present. (A.O.)

  2. 10 CFR 611.206 - Existing facilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Existing facilities. 611.206 Section 611.206 Energy... PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing facilities, give priority to those facilities that are oldest or...

  3. 33 CFR 154.1216 - Facility classification.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Facility classification. 154.1216... Vegetable Oils Facilities § 154.1216 Facility classification. (a) The Coast Guard classifies facilities that... classification of a facility that handles, stores, or transports animal fats or vegetable oils. The COTP may...

  4. Mound facility physical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Tonne, W.R.; Alexander, B.M.; Cage, M.R.; Hase, E.H.; Schmidt, M.J.; Schneider, J.E.; Slusher, W.; Todd, J.E.

    1993-12-01

    The purpose of this report is to provide a baseline physical characterization of Mound`s facilities as of September 1993. The baseline characterizations are to be used in the development of long-term future use strategy development for the Mound site. This document describes the current missions and alternative future use scenarios for each building. Current mission descriptions cover facility capabilities, physical resources required to support operations, current safety envelope and current status of facilities. Future use scenarios identify potential alternative future uses, facility modifications required for likely use, facility modifications of other uses, changes to safety envelope for the likely use, cleanup criteria for each future use scenario, and disposition of surplus equipment. This Introductory Chapter includes an Executive Summary that contains narrative on the Functional Unit Material Condition, Current Facility Status, Listing of Buildings, Space Plans, Summary of Maintenance Program and Repair Backlog, Environmental Restoration, and Decontamination and Decommissioning Programs. Under Section B, Site Description, is a brief listing of the Site PS Development, as well as Current Utility Sources. Section C contains Site Assumptions. A Maintenance Program Overview, as well as Current Deficiencies, is contained within the Maintenance Program Chapter.

  5. 18 CFR 1317.410 - Comparable facilities.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Comparable facilities... facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall be comparable to such facilities provided...

  6. Service quality in contracted facilities.

    Science.gov (United States)

    Rabbani, Fauziah; Pradhan, Nousheen Akber; Zaidi, Shehla; Azam, Syed Iqbal; Yousuf, Farheen

    2015-01-01

    The purpose of this paper is to explore the readiness of contracted and non-contracted first-level healthcare facilities in Pakistan to deliver quality maternal and neonatal health (MNH) care. A balanced scorecard (BSC) was used as the assessment framework. Using a cross-sectional study design, two rural health centers (RHCs) contracted out to Aga Khan Health Service, Pakistan were compared with four government managed RHCs. A BSC was designed to assess RHC readiness to deliver good quality MNH care. In total 20 indicators were developed, representing five BSC domains: health facility functionality, service provision, staff capacity, staff and patient satisfaction. Validated data collection tools were used to collect information. Pearson χ2, Fisher's Exact and the Mann-Whitney tests were applied as appropriate to detect significant service quality differences among the two facilities. Contracted facilities were generally found to be better than non-contracted facilities in all five BSC domains. Patients' inclination for facility-based delivery at contracted facilities was, however, significantly higher than non-contracted facilities (80 percent contracted vs 43 percent non-contracted, p=0.006). The study shows that contracting out initiatives have the potential to improve MNH care. This is the first study to compare MNH service delivery quality across contracted and non-contracted facilities using BSC as the assessment framework.

  7. Facility of aerosol filtration

    Energy Technology Data Exchange (ETDEWEB)

    Duverger de Cuy, G; Regnier, J

    1975-04-18

    Said invention relates to a facility of aerosol filtration, particularly of sodium aerosols. Said facility is of special interest for fast reactors where sodium fires involve the possibility of high concentrations of sodium aerosols which soon clog up conventional filters. The facility intended for continuous operation, includes at the pre-filtering stage, means for increasing the size of the aerosol particles and separating clustered particles (cyclone separator).

  8. 75 FR 55574 - Joint Public Roundtable on Swap Execution Facilities and Security-Based Swap Execution Facilities

    Science.gov (United States)

    2010-09-13

    ...; File No. 4-612] Joint Public Roundtable on Swap Execution Facilities and Security-Based Swap Execution Facilities AGENCY: Commodity Futures Trading Commission (``CFTC'') and Securities and Exchange Commission... discuss swap execution facilities and security-based swap execution facilities in the context of certain...

  9. 9 CFR 3.27 - Facilities, outdoor.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, outdoor. 3.27 Section 3.27... Pigs and Hamsters Facilities and Operating Standards § 3.27 Facilities, outdoor. (a) Hamsters shall not be housed in outdoor facilities. (b) Guinea pigs shall not be housed in outdoor facilities unless...

  10. Global Environment Facility |

    Science.gov (United States)

    environment Countries pledge US$4.1 billion to the Global Environment Facility Ringtail lemur mom with two of paradise Nations rally to protect global environment Countries pledge US$4.1 billion to the Global Environment Facility Stockholm, Sweden birds-eye view Events GEF-7 Replenishment Trung Truong Son Landscapes

  11. Realities of proximity facility siting

    International Nuclear Information System (INIS)

    DeMott, D.L.

    1981-01-01

    Numerous commercial nuclear power plant sites have 2 to 3 reactors located together, and a group of Facilities with capabilities for fuel fabrication, a nuclear reactor, a storage area for spent fuel, and a maintenance area for contaminated equipment and radioactive waste storage are being designed and constructed in the US. The proximity of these facilities to each other provides that the ordinary flow of materials remain within a limited area. Interactions between the various facilities include shared resources such as communication, fire protection, security, medical services, transportation, water, electrical, personnel, emergency planning, transport of hazardous material between facilities, and common safety and radiological requirements between facilities. This paper will explore the advantages and disadvantages of multiple facilities at one site. Problem areas are identified, and recommendations for planning and coordination are discussed

  12. The measurement of magnetic structure factors

    International Nuclear Information System (INIS)

    Forsyth, J.B.

    1978-01-01

    The subject is covered in sections, entitled: experimental methods (using unpolarized or polarized neutron diffraction); the polarized beam diffractometer (polarizing the incident beam, the control of neutron polarization, the diffractometer geometry, specimen environment - field and temperature, experiment control, multiple scattering, data processing); corrections and accuracy. (U.K.)

  13. Characterization of X-ray optics by soft X-ray diffractometry

    International Nuclear Information System (INIS)

    Biltoft, P.J.

    1988-01-01

    The authors have constructed a soft x-ray diffractometer to characterize layered synthetic microstructures (LSMs). The source, sample stage, and counter sections of the diffractometer operate under vacuum. The design differs from most others in two respects: the preamplifier and amplifier that process pulses from the subatmospheric-pressure gas-flow proportional counter are located outside the vacuum chamber and are separated from the proportional counter by approximately 76 cm of shielded cable; in addition, the conventional gear-driven, theta-two-theta diffractometer motion is accomplished with synchronized stepper motors. Characterizations of several LSMs have yielded data on d-spacing (distance between layers of different composition), critical angle, and peak reflectivity. Future work includes incorporation of an improved laser alignment system, in vacuo sample articulation (in addition to the theta-two-theta diffractometer movements), and a higher-flux photon source with a close-coupled fluorescent target carousel. Such a capability will permit multiple-energy diffraction work in a single pumpdown cycle

  14. Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Goldhagen, P.; Marino, S.A.; Randers-Pehrson, G.; Hall, E.J.

    1986-01-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which can be used to generate a variety of well-characterized radiation beams for research in radiobiology and radiological physics. It is part of the Radiological Research Laboratory (RRL), and its operation is supported as a National Facility by the US Department of Energy. RARAF is available to all potential users on an equal basis, with priorities based on the recommendations of a Scientific Advisory Committee. Facilities and services are provided to users, but the research projects themselves must be supported separately. This chapter presents a brief description of current experiments being carried out at RARAF and of the operation of the Facility from January through June, 1986. Operation of the Facility for all of 1985 was described in the 1985 Progress Report for RARAF. The experiments described here were supported by various Grants and Contracts from NIH and DOE and by the Statens Stralskyddsinstitut of Sweden

  15. Active use of urban park facilities

    DEFF Research Database (Denmark)

    Lindberg, Michael; Schipperijn, Jasper

    2015-01-01

    groups of the facilities. Facilities that provide the opportunity for games and playing activities are more used for PA than facilities directed at individual training of strength and fitness. The opportunity for socializing and playing while being physically active seems important for many users...... was mentioned as a key factor when designing facilities. Our results provide important knowledge to architects, planners and policy makers when aiming at designing activity-promoting facilities in UGS. Future studies need to further investigate the use of facilities among specific target groups, particularly......Abstract Urban green spaces (UGS), and more specific a higher number of facilities in UGS, have been positively associated with physical activity (PA). However, more detailed studies of which facilities generate high levels of PA, for which type of users, are relevant as existing knowledge...

  16. Environmental Toxicology Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Fully-equipped facilities for environmental toxicology researchThe Environmental Toxicology Research Facility (ETRF) located in Vicksburg, MS provides over 8,200 ft...

  17. 304 Concretion Facility Closure Plan

    International Nuclear Information System (INIS)

    1991-10-01

    The Hanford Site, located northwest of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. Recyclable scrap uranium with Zircaloy-2 and copper silicon allo , uranium-titanium alloy, beryllium/Zircaloy-2 alloy, and Zircaloy-2 chips and fines were secured in concrete billets (7.5-gal containers) in the 304 Concretion Facility (304 Facility), located in the 300 Area. The beryllium/Zircaloy-2 alloy and Zircaloy-2 chips and fines are designated as low-level radioactive mixed waste (LLRMW) with the characteristic of ignitability. The concretion process reduced the ignitability of the fines and chips for safe storage and shipment. This process has been discontinued and the 304 Concretion Facility is now undergoing closure as defined in the Resource Conservation and Recovery Act of 1976 (RCRA) and the Washington Administrative Code (WAC) Dangerous Waste Regulations, WAC 173-303-040 (Ecology 1991). This closure plan presents a description of the facility, the history of materials and wastes managed, and the procedures that will be followed to close the 304 Facility. The strategy for closure of the 304 Facility is presented in Section 6.0

  18. ORNL Isotopes Facilities Shutdown Program Plan

    International Nuclear Information System (INIS)

    Gibson, S.M.; Patton, B.D.; Sears, M.B.

    1990-10-01

    This plan presents the results of a technical and economic assessment for shutdown of the Oak Ridge National Laboratory (ORNL) isotopes production and distribution facilities. On December 11, 1989, the Department of Energy (DOE), Headquarters, in a memorandum addressed to DOE Oak Ridge Operations Office (DOE-ORO), gave instructions to prepare the ORNL isotopes production and distribution facilities, with the exception of immediate facility needs for krypton-85, tritium, and yttrium-90, for safe shutdown. In response to the memorandum, ORNL identified 17 facilities for shutdown. Each of these facilities is located within the ORNL complex with the exception of Building 9204-3, which is located at the Y-12 Weapons Production Plant. These facilities have been used extensively for the production of radioactive materials by the DOE Isotopes Program. They currently house a large inventory of radioactive materials. Over the years, these aging facilities have inherited the problems associated with storing and processing highly radioactive materials (i.e., facilities' materials degradation and contamination). During FY 1990, ORNL is addressing the requirements for placing these facilities into safe shutdown while maintaining the facilities under the existing maintenance and surveillance plan. The day-to-day operations associated with the surveillance and maintenance of a facility include building checks to ensure that building parameters are meeting the required operational safety requirements, performance of contamination control measures, and preventative maintenance on the facility and facility equipment. Shutdown implementation will begin in FY 1993, and shutdown completion will occur by the end of FY 1994

  19. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  20. Facility Registry Service (FRS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Facility Registry Service (FRS) provides an integrated source of comprehensive (air, water, and waste) environmental information about facilities across EPA,...

  1. Fast Flux Test Facility, Sodium Storage Facility project-specific project management plan

    International Nuclear Information System (INIS)

    Shank, D.R.

    1994-01-01

    This Project-Specific Project Management Plan describes the project management methods and controls used by the WHC Projects Department to manage Project 03-F-031. The Sodium Storage Facility provides for storage of the 260,000 gallons of sodium presently in the FFTF Plant. The facility will accept the molten sodium transferred from the FFTF sodium systems, and store the sodium in a solid state under an inert cover gas until such time as a Sodium Reaction Facility is available for final disposal of the sodium

  2. Fast Flux Test Facility, Sodium Storage Facility project-specific project management plan

    Energy Technology Data Exchange (ETDEWEB)

    Shank, D.R.

    1994-12-29

    This Project-Specific Project Management Plan describes the project management methods and controls used by the WHC Projects Department to manage Project 03-F-031. The Sodium Storage Facility provides for storage of the 260,000 gallons of sodium presently in the FFTF Plant. The facility will accept the molten sodium transferred from the FFTF sodium systems, and store the sodium in a solid state under an inert cover gas until such time as a Sodium Reaction Facility is available for final disposal of the sodium.

  3. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  4. Armament Technology Facility (ATF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Armament Technology Facility is a 52,000 square foot, secure and environmentally-safe, integrated small arms and cannon caliber design and evaluation facility....

  5. Simulation of facility operations and materials accounting for a combined reprocessing/MOX fuel fabrication facility

    International Nuclear Information System (INIS)

    Coulter, C.A.; Whiteson, R.; Zardecki, A.

    1991-01-01

    We are developing a computer model of facility operations and nuclear materials accounting for a facility that reprocesses spent fuel and fabricates mixed oxide (MOX) fuel rods and assemblies from the recovered uranium and plutonium. The model will be used to determine the effectiveness of various materials measurement strategies for the facility and, ultimately, of other facility safeguards functions as well. This portion of the facility consists of a spent fuel storage pond, fuel shear, dissolver, clarifier, three solvent-extraction stages with uranium-plutonium separation after the first stage, and product concentrators. In this facility area mixed oxide is formed into pellets, the pellets are loaded into fuel rods, and the fuel rods are fabricated into fuel assemblies. These two facility sections are connected by a MOX conversion line in which the uranium and plutonium solutions from reprocessing are converted to mixed oxide. The model of the intermediate MOX conversion line used in the model is based on a design provided by Mike Ehinger of Oak Ridge National Laboratory (private communication). An initial version of the simulation model has been developed for the entire MOX conversion and fuel fabrication sections of the reprocessing/MOX fuel fabrication facility, and this model has been used to obtain inventory difference variance estimates for those sections of the facility. A significant fraction of the data files for the fuel reprocessing section have been developed, but these data files are not yet complete enough to permit simulation of reprocessing operations in the facility. Accordingly, the discussion in the following sections is restricted to the MOX conversion and fuel fabrication lines. 3 tabs

  6. Lesotho - Health Facility Survey

    Data.gov (United States)

    Millennium Challenge Corporation — The main objective of the 2011 Health Facility Survey (HFS) was to establish a baseline for informing the Health Project performance indicators on health facilities,...

  7. 20 CFR 416.1023 - Facilities.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Facilities. 416.1023 Section 416.1023... Facilities. (a) Space, equipment, supplies, and other services. Subject to appropriate Federal funding, the... and prompt disability determinations. (b) Location of facilities. Subject to appropriate Federal...

  8. Procedure for estimating facility decommissioning costs for non-fuel-cycle nuclear facilities

    International Nuclear Information System (INIS)

    Short, S.M.

    1988-01-01

    The Nuclear Regulatory Commission (NRC) staff has been reappraising its regulatory position relative to the decommissioning of nuclear facilities over the last several years. Approximately 30 reports covering the technology, safety, and costs of decommissioning reference nuclear facilities have been published during this period in support of this effort. One of these reports, Technology, Safety, and Costs of Decommissioning Reference Non-Fuel-Cycle Nuclear Facilities (NUREG/CR-1754), was published in 1981 and was felt by the NRC staff to be outdated. The Pacific Northwest Laboratory (PNL) was asked by the NRC staff to revise the information provided in this report to reflect the latest information on decommissioning technology and costs and publish the results as an addendum to the previous report. During the course of this study, the NRC staff also asked that PNL provide a simplified procedure for estimating decommissioning costs of non-fuel-cycle nuclear facilities. The purpose being to provide NRC staff with the means to easily generate their own estimate of decommissioning costs for a given facility for comparison against a licensee's submittal. This report presents the procedure developed for use by NRC staff

  9. PUREX facility preclosure work plan

    International Nuclear Information System (INIS)

    Engelmann, R.H.

    1997-01-01

    This preclosure work plan presents a description of the PUREX Facility, the history of the waste managed, and addresses transition phase activities that position the PUREX Facility into a safe and environmentally secure configuration. For purposes of this documentation, the PUREX Facility does not include the PUREX Storage Tunnels (DOE/RL-90/24). Information concerning solid waste management units is discussed in the Hanford Facility Dangerous Waste Permit Application, General Information Portion (DOE/RL-91-28, Appendix 2D)

  10. Facilities for US Radioastronomy.

    Science.gov (United States)

    Thaddeus, Patrick

    1982-01-01

    Discusses major developments in radioastronomy since 1945. Topics include proposed facilities, very-long-baseline interferometric array, millimeter-wave telescope, submillimeter-wave telescope, and funding for radioastronomy facilities and projects. (JN)

  11. Sanford Underground Research Facility - The United State's Deep Underground Research Facility

    Science.gov (United States)

    Vardiman, D.

    2012-12-01

    The 2.5 km deep Sanford Underground Research Facility (SURF) is managed by the South Dakota Science and Technology Authority (SDSTA) at the former Homestake Mine site in Lead, South Dakota. The US Department of Energy currently supports the development of the facility using a phased approach for underground deployment of experiments as they obtain an advanced design stage. The geology of the Sanford Laboratory site has been studied during the 125 years of operations at the Homestake Mine and more recently as part of the preliminary geotechnical site investigations for the NSF's Deep Underground Science and Engineering Laboratory project. The overall geology at DUSEL is a well-defined stratigraphic sequence of schist and phyllites. The three major Proterozoic units encountered in the underground consist of interbedded schist, metasediments, and amphibolite schist which are crosscut by Tertiary rhyolite dikes. Preliminary geotechnical site investigations included drift mapping, borehole drilling, borehole televiewing, in-situ stress analysis, laboratory analysis of core, mapping and laser scanning of new excavations, modeling and analysis of all geotechnical information. The investigation was focused upon the determination if the proposed site rock mass could support the world's largest (66 meter diameter) deep underground excavation. While the DUSEL project has subsequently been significantly modified, these data are still available to provide a baseline of the ground conditions which may be judiciously extrapolated throughout the entire Proterozoic rock assemblage for future excavations. Recommendations for facility instrumentation and monitoring were included in the preliminary design of the DUSEL project design and include; single and multiple point extensometers, tape extensometers and convergence measurements (pins), load cells and pressure cells, smart cables, inclinometers/Tiltmeters, Piezometers, thermistors, seismographs and accelerometers, scanners (laser

  12. EPA Facility Registry System (FRS): NCES

    Science.gov (United States)

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Center for Education Statistics (NCES). The primary federal database for collecting and analyzing data related to education in the United States and other Nations, NCES is located in the U.S. Department of Education, within the Institute of Education Sciences. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA00e2??s national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NCES school facilities once the NCES data has been integrated into the FRS database. Additional information on FRS is available at the EPA website http://www.epa.gov/enviro/html/fii/index.html.

  13. Trauma facilities in Denmark - A nationwide cross-sectional benchmark study of facilities and trauma care organisation

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C.

    2018-01-01

    Background: Trauma is a leading cause of death among adults aged trauma facilities and the use multidisciplinary trauma teams. Because knowledge is sparse on the existing distribution of trauma facilities...... and the organisation of trauma care in Denmark, the aim of this study was to identify all Danish facilities that care for traumatized patients and to investigate the diversity in organization of trauma management. Methods: We conducted a systematic observational cross-sectional study. First, all hospitals in Denmark...... were identified via online services and clarifying phone calls to each facility. Second, all trauma care manuals on all facilities that receive traumatized patients were gathered. Third, anesthesiologists and orthopedic surgeons on call at all trauma facilities were contacted via telephone...

  14. Survey of solar thermal test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Masterson, K.

    1979-08-01

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilities is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.

  15. 20 CFR 404.1623 - Facilities.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Facilities. 404.1623 Section 404.1623...- ) Determinations of Disability Administrative Responsibilities and Requirements § 404.1623 Facilities. (a) Space... determinations. (b) Location of facilities. Subject to appropriate Federal funding, the State will determine the...

  16. Capital Ideas for Facilities Management.

    Science.gov (United States)

    Golding, Stephen T.; Gordon, Janet; Gravina, Arthur

    2001-01-01

    Asserting that just like chief financial officers, higher education facilities specialists must maximize the long-term performance of assets under their care, describes strategies for strategic facilities management. Discusses three main approaches to facilities management (insourcing, cosourcing, and outsourcing) and where boards of trustees fit…

  17. Medical cyclotron facilities

    International Nuclear Information System (INIS)

    1984-09-01

    This report examines the separate proposals from the Austin Hospital and the Australian Atomic Energy Commission for a medical cyclotron facility. The proponents have argued that a cyclotron facility would benefit Australia in areas of patient care, availability and export of radioisotopes, and medical research. Positron emission tomography (PET) and neutron beam therapy are also examined

  18. Facility planning and site development

    International Nuclear Information System (INIS)

    Reisman, R.C.; Handmaker, H.

    1986-01-01

    Planning for a magnetic resonance imaging (MRI) facility should provide for the efficient operation of current and future MRI devices and must also take into consideration a broad range of general planning principles. Control of budgeted facility costs and construction schedules is of increasing importance due to the magnitude of expense of MRI facility development as well as the need to protect institutional or entrepreneurial investment. In a competitive environment facility costs may be the determining factor in a project's success

  19. Current status of neutron scattering in Thailand

    International Nuclear Information System (INIS)

    Kornduangkaeo, Areeratt; Pongkasem, Somchai; Putchar, Suriya; Ampornrat, Pantip; Kajornrith, Varavuth; Chamchang, Jipawat

    2006-01-01

    The current neutron powder diffractometer at the Thai Research Reactor-1/Modification 1 (TRR-1/M1) has been modified from the obsolete neutron diffractometer which had been used during 1968-1975. The upgraded diffractometer has medium resolution and is appropriate for studying samples with small unit cell dimensions and training university students in the field of neutron scattering. This paper describes the current activities of neutron scattering research in Thailand, the current status of a new research reactor project at Ongkarak for enlarging the perspectives of its utilization in the future as well as the organizational reformation of the Office of Atomic Energy for Peace (OAEP). (author)

  20. European Synchrotron Radiation Facility

    International Nuclear Information System (INIS)

    Buras, B.

    1985-01-01

    How a European Synchrotron Radiation Facility has developed into a detailed proposal recently accepted as the basis for construction of the facility at Grenoble is discussed. In November 1977, the General Assembly of the European Science Foundation (ESF) approved the report of the ESF working party on synchrotron radiation entitled Synchrotron Radiation - a Perspective View for Europe. This report contained as one of its principal recommendations that work should commence on a feasibility study for a European synchrotron radiation laboratory having a dedicated hard X-ray storage ring and appropriate advanced instrumentation. In order to prepare a feasibility study the European Science Foundation set up the Ad-hoc Committee on Synchrotron Radiation, which in turn formed two working groups: one for the machine and another for instrumentation. This feasibility study was completed in 1979 with the publication of the Blue Book describing in detail the so called 1979 European Synchrotron Radiation Facility. The heart of the facility was a 5 GeV electron storage ring and it was assumed that mainly the radiation from bending magnets will be used. The facility is described

  1. Trauma facilities in Denmark - a nationwide cross-sectional benchmark study of facilities and trauma care organisation.

    Science.gov (United States)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C; Frederiksen, Christian A; Laursen, Christian B; Sloth, Erik; Mølgaard, Ole; Knudsen, Lars; Kirkegaard, Hans

    2018-03-27

    Trauma is a leading cause of death among adults aged facilities and the use multidisciplinary trauma teams. Because knowledge is sparse on the existing distribution of trauma facilities and the organisation of trauma care in Denmark, the aim of this study was to identify all Danish facilities that care for traumatized patients and to investigate the diversity in organization of trauma management. We conducted a systematic observational cross-sectional study. First, all hospitals in Denmark were identified via online services and clarifying phone calls to each facility. Second, all trauma care manuals on all facilities that receive traumatized patients were gathered. Third, anesthesiologists and orthopedic surgeons on call at all trauma facilities were contacted via telephone for structured interviews. A total of 22 facilities in Denmark were found to receive traumatized patients. All facilities used a trauma care manual and all had a multidisciplinary trauma team. The study found three different trauma team activation criteria and nine different compositions of teams who participate in trauma care. Training was heterogeneous and, beyond the major trauma centers, databases were only maintained in a few facilities. The study established an inventory of the existing Danish facilities that receive traumatized patients. The trauma team activation criteria and the trauma teams were heterogeneous in both size and composition. A national database for traumatized patients, research on nationwide trauma team activation criteria, and team composition guidelines are all called for.

  2. 7 CFR 51.57 - Facilities.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Facilities. 51.57 Section 51.57 Agriculture... Requirements for Plants Operating Under Continuous Inspection on A Contract Basis § 51.57 Facilities. Each packing plant shall be equipped with adequate sanitary facilities and accommodations, including but not...

  3. 50 CFR 260.100 - Facilities.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Facilities. 260.100 Section 260.100... Basis 1 § 260.100 Facilities. Each official establishment shall be equipped with adequate sanitary facilities and accommodations, including, but not being limited to, the following: (a) Containers approved...

  4. Liquefied Gaseous Fuels Spill Test Facility

    International Nuclear Information System (INIS)

    1993-02-01

    The US Department of Energy's liquefied Gaseous Fuels Spill Test Facility is a research and demonstration facility available on a user-fee basis to private and public sector test and training sponsors concerned with safety aspects of hazardous chemicals. Though initially designed to accommodate large liquefied natural gas releases, the Spill Test Facility (STF) can also accommodate hazardous materials training and safety-related testing of most chemicals in commercial use. The STF is located at DOE's Nevada Test Site near Mercury, Nevada, USA. Utilization of the Spill Test Facility provides a unique opportunity for industry and other users to conduct hazardous materials testing and training. The Spill Test Facility is the only facility of its kind for either large- or small-scale testing of hazardous and toxic fluids including wind tunnel testing under controlled conditions. It is ideally suited for test sponsors to develop verified data on prevention, mitigation, clean-up, and environmental effects of toxic and hazardous gaseous liquids. The facility site also supports structured training for hazardous spills, mitigation, and clean-up. Since 1986, the Spill Test Facility has been utilized for releases to evaluate the patterns of dispersion, mitigation techniques, and combustion characteristics of select materials. Use of the facility can also aid users in developing emergency planning under US P.L 99-499, the Superfund Amendments and Reauthorization Act of 1986 (SARA) and other regulations. The Spill Test Facility Program is managed by the US Department of Energy (DOE), Office of Fossil Energy (FE) with the support and assistance of other divisions of US DOE and the US Government. DOE/FE serves as facilitator and business manager for the Spill Test Facility and site. This brief document is designed to acquaint a potential user of the Spill Test Facility with an outline of the procedures and policies associated with the use of the facility

  5. 44 CFR 331.5 - Production facilities.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Production facilities. 331.5... AND FACILITIES IN LABOR SURPLUS AREAS § 331.5 Production facilities. All Federal departments and... production facilities, including expansion, to the extent that such selection is consistent with existing law...

  6. 28 CFR 54.410 - Comparable facilities.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Comparable facilities. 54.410 Section 54... in Education Programs or Activities Prohibited § 54.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities...

  7. Facilities Performance Indicators Report, 2008-09

    Science.gov (United States)

    Hills, Christina, Ed.

    2010-01-01

    This paper features another expanded Web-based Facilities Performance Indicators Report (FPI). The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. The 2008-09 iteration of the Web-based Facilities Performance Indicators Survey was posted and…

  8. Facility Management's Role in Organizational Sustainability

    Science.gov (United States)

    Adams, Gregory K.

    2013-01-01

    Facility managers have questions about sustainability. How do an organization's physical facilities--its built environment--and the management of them, influence the sustainability of the organization or institution as a whole? How important is Facility Management (FM) to the overall sustainability profile of an organization? Facility managers…

  9. Fusion Materials Irradiation Test Facility: a facility for fusion-materials qualification

    International Nuclear Information System (INIS)

    Trego, A.L.; Hagan, J.W.; Opperman, E.K.; Burke, R.J.

    1983-01-01

    The Fusion Materials Irradiation Test Facility will provide a unique testing environment for irradiation of structural and special purpose materials in support of fusion power systems. The neutron source will be produced by a deuteron-lithium stripping reaction to generate high energy neutrons to ensure damage similar to that of a deuterium-tritium neutron spectrum. The facility design is now ready for the start of construction and much of the supporting lithium system research has been completed. Major testing of key low energy end components of the accelerator is about to commence. The facility, its testing role, and the status and major aspects of its design and supporting system development are described

  10. Designing Facilities for Collaborative Operations

    Science.gov (United States)

    Norris, Jeffrey; Powell, Mark; Backes, Paul; Steinke, Robert; Tso, Kam; Wales, Roxana

    2003-01-01

    A methodology for designing operational facilities for collaboration by multiple experts has begun to take shape as an outgrowth of a project to design such facilities for scientific operations of the planned 2003 Mars Exploration Rover (MER) mission. The methodology could also be applicable to the design of military "situation rooms" and other facilities for terrestrial missions. It was recognized in this project that modern mission operations depend heavily upon the collaborative use of computers. It was further recognized that tests have shown that layout of a facility exerts a dramatic effect on the efficiency and endurance of the operations staff. The facility designs (for example, see figure) and the methodology developed during the project reflect this recognition. One element of the methodology is a metric, called effective capacity, that was created for use in evaluating proposed MER operational facilities and may also be useful for evaluating other collaboration spaces, including meeting rooms and military situation rooms. The effective capacity of a facility is defined as the number of people in the facility who can be meaningfully engaged in its operations. A person is considered to be meaningfully engaged if the person can (1) see, hear, and communicate with everyone else present; (2) see the material under discussion (typically data on a piece of paper, computer monitor, or projection screen); and (3) provide input to the product under development by the group. The effective capacity of a facility is less than the number of people that can physically fit in the facility. For example, a typical office that contains a desktop computer has an effective capacity of .4, while a small conference room that contains a projection screen has an effective capacity of around 10. Little or no benefit would be derived from allowing the number of persons in an operational facility to exceed its effective capacity: At best, the operations staff would be underutilized

  11. 14 CFR 142.15 - Facilities.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Facilities. 142.15 Section 142.15... OTHER CERTIFICATED AGENCIES TRAINING CENTERS General § 142.15 Facilities. (a) An applicant for, or..., sanitation, and health codes; and (2) The facilities used for instruction are not routinely subject to...

  12. Concrete structures for nuclear facilities

    International Nuclear Information System (INIS)

    1996-01-01

    The detailed requirements for the design and fabrication of the concrete structures for nuclear facilities and for the documents to be submitted to the Finnish Centre for Radiation and Nuclear Safety (STUK) are given in the guide. It also sets the requirements for the inspection of concrete structures during the construction and operation of facilities. The requirements of the guide primarily apply to new construction. As regards the repair and modification of nuclear facilities built before its publication, the guide is followed to the extent appropriate. The regulatory activities of the Finnish Centre for Radiation and Nuclear Safety during a nuclear facility's licence application review and during the construction and operation of the facility are summarised in the guide YVL 1.1

  13. 30 CFR 57.20008 - Toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 57.20008 Section 57.20008....20008 Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be...

  14. 30 CFR 57.6161 - Auxiliary facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary facilities. 57.6161 Section 57.6161...-Underground Only § 57.6161 Auxiliary facilities. (a) Auxiliary facilities used to store explosive material near work places shall be wooden, box-type containers equipped with covers or doors, or facilities...

  15. 14 CFR 1251.301 - Existing facilities.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Existing facilities. 1251.301 Section 1251... HANDICAP Accessibility § 1251.301 Existing facilities. (a) Accessibility. A recipient shall operate each... existing facilities or every part of a facility accessible to and usable by handicapped persons. (b...

  16. 9 CFR 3.102 - Facilities, indoor.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, indoor. 3.102 Section 3... Marine Mammals Facilities and Operating Standards § 3.102 Facilities, indoor. (a) Ambient temperature. The air and water temperatures in indoor facilities shall be sufficiently regulated by heating or...

  17. 36 CFR 13.166 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.166... facilities. A temporary facility or structure directly and necessarily related to the taking of subsistence... facilities which shall be published annually in accordance with § 1.7 of this chapter. ...

  18. Cold Vacuum Drying Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  19. Two new tensile devices for X-ray diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Freri, N.; Tintori, A.; Depero, L.E.; Sangaletti, L. [Brescia Univ. (Italy); Cernuschi, F.; Ghia, S. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-12-01

    Two tensile devices were designed to be used with parallel beam and parafocusing-geometry diffractometers. In thefirst case the device was designed to be attached to a strainflex diffractometer by Rigaku Inc., dedicated to stress analysis and commonly used in metallurgical industry. Since the sample does not move during the measurement, the tensile device can be kept fixed on the experimental table. The device design takes into account the steric hindrance by moving parts of diffractometer. The maximun load that can be applied to the sample is 60.000 N. An attachement to a Siemens D5000 diffractometer with Eulerian cradle has also benn designed for applying a load up tp 6000 N to a sample in the parafocusing-geometry. The installation does not require a re-alignment of the diffractometer. In both cases strain gages were applied to both sides of the specimen for the simultaneous determination of the macroscopic strains. Experiments based on the use of these devices are planned to determine the crystallographic elastic constants and study the influence of the microstructure on the mechanical behaviour of residual stresses in the zone of almost static stresses as well as the influence of residual stresses on uniaxially loaded samples. In addition, by using these devices, it is possible to measure the unstressed d-0 spacings providing useful information in the neutron diffraction study fo stress fields in steel samples.

  20. The Birmingham Irradiation Facility

    International Nuclear Information System (INIS)

    Dervan, P.; French, R.; Hodgson, P.; Marin-Reyes, H.; Wilson, J.

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1×1 cm 2 ) silicon sensors

  1. The Birmingham Irradiation Facility

    CERN Document Server

    Dervan, P; Hodgson, P; Marin-Reyes, H; Wilson, J

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS [1] will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1 x 1 cm^2 ) silicon sensors.

  2. DUPIC facility engineering

    International Nuclear Information System (INIS)

    Park, J. J.; Lee, H. H.; Kim, K. H.

    2002-03-01

    With starting DUPIC fuel fabrication experiment by using spent fuels, 1) operation and refurbishment for DFDF (DUPIC fuel development facility), and 2) operation and improvement of transportation equipment for radioactive materials between facilities became the objectives of this study. This report describes objectives of the project, necessities, state of related technology, R and D scope, R and D results, proposal for application etc

  3. PRTR/309 building nuclear facility preliminary

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1994-01-01

    The hazard classification of the Plutonium Recycle Test Reactor (PRTR)/309 building as a ''Radiological Facility'' and the office portions as ''Other Industrial Facility'' are documented by this report. This report provides: a synopsis of the history and facility it's uses; describes major area of the facility; and assesses the radiological conditions for the facility segments. The assessment is conducted using the hazard category threshold values, segmentation methodology, and graded approach guidance of DOE-STD-1027-92

  4. The ORION Facility

    International Nuclear Information System (INIS)

    Noble, Robert

    2003-01-01

    ORION will be a user-oriented research facility for understanding the physics and developing the technology for future high-energy particle accelerators, as well as for research in related fields. The facility has as its centerpiece the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). The NLCTA will be modified with the addition of a new, high-brightness photoinjector, its drive laser, an S-band rf power system, a user laser room, a low-energy experimental hall supplied with electron beams up to 60 MeV in energy, and a high-energy hall supplied with beams up to 350 MeV. The facility design and parameters are described here along with highlights from the 2nd ORION Workshop held in February 2003

  5. Ouellette Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Test Facility is a joint Army/Navy state-of-the-art facility (8,100 ft2) that was designed to:Evaluate and characterize the effect of flame and thermal...

  6. 30 CFR 816.181 - Support facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Support facilities. 816.181 Section 816.181... § 816.181 Support facilities. (a) Support facilities shall be operated in accordance with a permit... results. (b) In addition to the other provisions of this part, support facilities shall be located...

  7. 10 CFR 4.127 - Existing facilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Existing facilities. 4.127 Section 4.127 Energy NUCLEAR... 1973, as Amended Discriminatory Practices § 4.127 Existing facilities. (a) Accessibility. A recipient... make each of its existing facilities or every part of an existing facility accessible to and usable by...

  8. 30 CFR 57.6160 - Main facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main facilities. 57.6160 Section 57.6160...-Underground Only § 57.6160 Main facilities. (a) Main facilities used to store explosive material underground... facilities will not prevent escape from the mine, or cause detonation of the contents of another storage...

  9. 45 CFR 1170.32 - Existing facilities.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Existing facilities. 1170.32 Section 1170.32... ASSISTED PROGRAMS OR ACTIVITIES Accessibility § 1170.32 Existing facilities. (a) Accessibility. A recipient... require a recipient to make each of its existing facilities or every part of a facility accessible to and...

  10. 30 CFR 56.20008 - Toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 56.20008 Section 56.20008... Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and...

  11. 45 CFR 605.22 - Existing facilities.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Existing facilities. 605.22 Section 605.22 Public... Accessibility § 605.22 Existing facilities. (a) Accessibility. A recipient shall operate each program or... existing facilities or every part of a facility accessible to and usable by qualified handicapped persons...

  12. 32 CFR 196.410 - Comparable facilities.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Comparable facilities. 196.410 Section 196.410....410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall be comparable to such...

  13. 9 CFR 3.25 - Facilities, general.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, general. 3.25 Section 3.25... Pigs and Hamsters Facilities and Operating Standards § 3.25 Facilities, general. (a) Structural strength. Indoor and outdoor housing facilities for guinea pigs or hamsters shall be structurally sound and...

  14. 10 CFR 1040.72 - Existing facilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Existing facilities. 1040.72 Section 1040.72 Energy... § 1040.72 Existing facilities. (a) Accessibility. A recipient shall operate any program or activity to... facilities or every part of a facility accessible to and useable by handicapped persons. (b) Methods. A...

  15. 45 CFR 1151.22 - Existing facilities.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Existing facilities. 1151.22 Section 1151.22... Prohibited Accessibility § 1151.22 Existing facilities. (a) A recipient shall operate each program or... make each of its existing facilities or every part of a facility accessible to and usable by...

  16. 30 CFR 817.181 - Support facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Support facilities. 817.181 Section 817.181... ACTIVITIES § 817.181 Support facilities. (a) Support facilities shall be operated in accordance with a permit.... (b) In addition to the other provisions of this part, support facilities shall be located, maintained...

  17. 36 CFR 1211.410 - Comparable facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Comparable facilities. 1211... § 1211.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall be comparable to...

  18. 10 CFR 1042.410 - Comparable facilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Comparable facilities. 1042.410 Section 1042.410 Energy... Activities Prohibited § 1042.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall...

  19. 44 CFR 19.410 - Comparable facilities.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Comparable facilities. 19.410... Activities Prohibited § 19.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall...

  20. Establishment and Operation of User Facilities

    International Nuclear Information System (INIS)

    Cho, Yong Sub; Kwon, Hyeok Jung; Kim, Kye Ryung

    2008-05-01

    PEFP(Proton Engineering Frontier Project) has launched on a new enterprise to develop the technologies for the future relating to the proton beam and spin-off technologies in 2002. PEFP planned to supply 20MeV and 100MeV proton beam by the development of the 100MeV, 20mA linear accelerator during ten years from 2002 to 2012. The final goal of this project is establishment of 20MeV and 100MeV user facilities. To do this, we must develop the key technologies for establishing user facilities. Before the main facilities are normally operated, we have established the test user facilities to support various kinds of users' basic experiments and pilot studies. The necessity of this research are as follows; - Domestic achievement of key technologies for the development and design of the user facilities for the several tens to hundreds MeV class high current proton beam - Beam application researches can be revitalized and improved the efficiency by the establishment and operation of user facilities and test facilities. - Ion implantation facilities have contributed to increase Industrial applications - It is more effective in saving money that users use the PEFP's user facility than other country's user facilities. - It is possible to contribute to the local society and commercialize the beam application technologies by the establishment of PEFP's research branch in Kyungju

  1. Making of the NSTX Facility

    International Nuclear Information System (INIS)

    Neumeyer, C.; Ono, M.; Kaye, S.M.; Peng, Y.-K.M.

    1999-01-01

    The NSTX (National Spherical Torus Experiment) facility located at Princeton Plasma Physics Laboratory is the newest national fusion science experimental facility for the restructured US Fusion Energy Science Program. The NSTX project was approved in FY 97 as the first proof-of-principle national fusion facility dedicated to the spherical torus research. On Feb. 15, 1999, the first plasma was achieved 10 weeks ahead of schedule. The project was completed on budget and with an outstanding safety record. This paper gives an overview of the NSTX facility construction and the initial plasma operations

  2. Needs of Advanced Safeguards Technologies for Future Nuclear Fuel Cycle (FNFC) Facilities and a Trial Application of SBD Concept to Facility Design of a Hypothetical FNFC Facility

    International Nuclear Information System (INIS)

    Seya, M.; Hajima, R.; Nishimori, N.; Hayakawa, T.; Kikuzawa, N.; Shizuma, T.; Fujiwara, M.

    2010-01-01

    Some of future nuclear fuel cycle (FNFC) facilities are supposed to have the characteristic features of very large throughput of plutonium, low decontamination reprocessing (no purification process; existence of certain amount of fission products (FP) in all process material), full minor actinides (MA) recycle, and treatment of MOX with FP and MA in fuel fabrication. In addition, the following international safeguards requirements have to be taken into account for safeguards approaches of the FNFC facilities. -Application of integrated safeguards (IS) approach; -Remote (unattended) verification; - 'Safeguards by Design' (SBD) concept. These features and requirements compel us to develop advanced technologies, which are not emerged yet. In order to realize the SBD, facility designers have to know important parts of design information on advanced safeguards systems before starting the facility design. The SBD concept requires not only early start of R and D of advanced safeguards technologies (before starting preliminary design of the facility) but also interaction steps between researchers working on safeguards systems and nuclear facility designers. The interaction steps are follows. Step-1; researchers show images of advanced safeguards systems to facility designers based on their research. Step-2; facility designers take important design information on safeguards systems into process systems of demonstration (or test) facility. Step-3; demonstration and improvement of both systems based on the conceptual design. Step-4; Construction of a FNFC facility with the advanced safeguards systems We present a trial application of the SBD concept to a hypothetical FNFC facility with an advanced hybrid K-edge densitometer and a Pu NDA system for spent nuclear fuel assembly using laser Compton scattering (LCS) X-rays and γ-rays and other advanced safeguards systems. (author)

  3. Neighbourhood facilities for sustainability

    CSIR Research Space (South Africa)

    Gibberd, Jeremy T

    2013-01-01

    Full Text Available . In this paper these are referred to as ‘Neighbourhood Facilities for Sustainability’. Neighbourhood Facilities for Sustainability (NFS) are initiatives undertaken by individuals and communities to build local sustainable systems which not only improve...

  4. 340 Waste Handling Facility interim safety basis

    International Nuclear Information System (INIS)

    Bendixsen, R.B.

    1995-01-01

    This document establishes the interim safety basis (ISB) for the 340 Waste Handling Facility (340 Facility). An ISB is a documented safety basis that provides a justification for the continued operation of the facility until an upgraded final safety analysis report is prepared that complies with US Department of Energy (DOE) Order 5480.23, Nuclear Safety Analysis Reports. The ISB for the 340 Facility documents the current design and operation of the facility. The 340 Facility ISB (ISB-003) is based on a facility walkdown and review of the design and operation of the facility, as described in the existing safety documentation. The safety documents reviewed, to develop ISB-003, include the following: OSD-SW-153-0001, Operating Specification Document for the 340 Waste Handling Facility (WHC 1990); OSR-SW-152-00003, Operating Limits for the 340 Waste Handling Facility (WHC 1989); SD-RE-SAP-013, Safety Analysis Report for Packaging, Railroad Liquid Waste Tank Cars (Mercado 1993); SD-WM-TM-001, Safety Assessment Document for the 340 Waste Handling Facility (Berneski 1994a); SD-WM-SEL-016, 340 Facility Safety Equipment List (Berneski 1992); and 340 Complex Fire Hazard Analysis, Draft (Hughes Assoc. Inc. 1994)

  5. Facility Effluent Monitoring Plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Carter, G.J.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updates as a minimum every three years

  6. 10 CFR 5.410 - Comparable facilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Comparable facilities. 5.410 Section 5.410 Energy NUCLEAR... Prohibited § 5.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall be comparable to...

  7. Safety of magnetic fusion facilities: Guidance

    International Nuclear Information System (INIS)

    1996-05-01

    This document provides guidance for the implementation of the requirements identified in DOE-STD-6002-96, Safety of Magnetic Fusion Facilities: Requirements. This guidance is intended for the managers, designers, operators, and other personnel with safety responsibilities for facilities designated as magnetic fusion facilities. While the requirements in DOE-STD-6002-96 are generally applicable to a wide range of fusion facilities, this Standard, DOE-STD-6003-96, is concerned mainly with the implementation of those requirements in large facilities such as the International Thermonuclear Experimental Reactor (ITER). Using a risk-based prioritization, the concepts presented here may also be applied to other magnetic fusion facilities. This Standard is oriented toward regulation in the Department of Energy (DOE) environment as opposed to regulation by other regulatory agencies. As the need for guidance involving other types of fusion facilities or other regulatory environments emerges, additional guidance volumes should be prepared. The concepts, processes, and recommendations set forth here are for guidance only. They will contribute to safety at magnetic fusion facilities

  8. 21 CFR 1271.190 - Facilities.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Facilities. 1271.190 Section 1271.190 Food and... CELLULAR AND TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.190 Facilities. (a) General. Any facility used in the manufacture of HCT/Ps must be of suitable size, construction, and location to prevent...

  9. Samarbejdsformer og Facilities Management

    DEFF Research Database (Denmark)

    Storgaard, Kresten

    Resultater fra en surveyundersøgelse om fordele og ulemper ved forskellige samarbejdsformer indenfor Facilities Management fremlægges.......Resultater fra en surveyundersøgelse om fordele og ulemper ved forskellige samarbejdsformer indenfor Facilities Management fremlægges....

  10. Establishment and Operation of User Facilities

    International Nuclear Information System (INIS)

    Kim, Kye Ryung; Park, B. S.; Lim, Y. K.; Lee, S. K.; Jung, J. P.

    2005-08-01

    The final goal of this project is to establish the proton beam user facility which can offer the suitable proton beam for the user's demand. In the first phase we developed the key technologies that were required for the establishment of 20MeV and 100MeV proton user facilities. The user's demand survey was also achieved, and the test user facility was established on the results of the demand survey. Using the test facility, the users performed their pilot studies. Now, we have finished the conceptual design for 20MeV proton user facility. During the first phase we performed the user's demand survey and produced many materials related to the proton beam utilizations in domestic or abroad. The survey results were reflected on the establishment of the test user facility and the conceptual design of 20MeV/100MeV proton beam user facilities. We have developed the key technologies which concern to beam energy control, flux control, uniform irradiation, dose and uniformity measurement, proton energy measurement, SOBP(Spread-out Bragg Peak) system using a rotating range modulator, and carried out the conceptual design of 20MeV proton user facility. The test user facility has been constructed and operated for both verifying the developed key technologies and performing the user's preliminary experiments. 45MeV low flux user facility was constructed in 2003 and has performed a lot of irradiation experiments. The development of 1.8MeV test user facility was completed. Also the low energy user facility that KAERI kept was upgraded and used for many users. Therefore, we provided our users with various beams. On the other hand, the following activities were carried out, such as, inviting the oversea researchers, giving support to users to use the beam in domestic and abroad, discussing the beam utilization technologies by visiting the foreign user facilities, etc

  11. Berkeley Low Background Facility

    International Nuclear Information System (INIS)

    Thomas, K. J.; Norman, E. B.; Smith, A. R.; Poon, A. W. P.; Chan, Y. D.; Lesko, K. T.

    2015-01-01

    The Berkeley Low Background Facility (BLBF) at Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background laboratory on the surface at LBNL and at the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products; active screening via neutron activation analysis for U,Th, and K as well as a variety of stable isotopes; and neutron flux/beam characterization measurements through the use of monitors. A general overview of the facilities, services, and sensitivities will be presented. Recent activities and upgrades will also be described including an overview of the recently installed counting system at SURF (recently relocated from Oroville, CA in 2014), the installation of a second underground counting station at SURF in 2015, and future plans. The BLBF is open to any users for counting services or collaboration on a wide variety of experiments and projects

  12. Subsurface Facility System Description Document

    International Nuclear Information System (INIS)

    Eric Loros

    2001-01-01

    The Subsurface Facility System encompasses the location, arrangement, size, and spacing of the underground openings. This subsurface system includes accesses, alcoves, and drifts. This system provides access to the underground, provides for the emplacement of waste packages, provides openings to allow safe and secure work conditions, and interfaces with the natural barrier. This system includes what is now the Exploratory Studies Facility. The Subsurface Facility System physical location and general arrangement help support the long-term waste isolation objectives of the repository. The Subsurface Facility System locates the repository openings away from main traces of major faults, away from exposure to erosion, above the probable maximum flood elevation, and above the water table. The general arrangement, size, and spacing of the emplacement drifts support disposal of the entire inventory of waste packages based on the emplacement strategy. The Subsurface Facility System provides access ramps to safely facilitate development and emplacement operations. The Subsurface Facility System supports the development and emplacement operations by providing subsurface space for such systems as ventilation, utilities, safety, monitoring, and transportation

  13. Hanford surplus facilities hazards identification document

    International Nuclear Information System (INIS)

    Egge, R.G.

    1997-01-01

    This document provides general safety information needed by personnel who enter and work in surplus facilities managed by Bechtel Hanford, Inc. The purpose of the document is to enhance access control of surplus facilities, educate personnel on the potential hazards associated with these facilities prior to entry, and ensure that safety precautions are taken while in the facility

  14. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... flush toilet facilities. 71.400 Section 71.400 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE... installations and at the surface worksites of such mine. (Note: Sanitary facilities at surface work areas of...

  15. Hot-cell verification facility

    International Nuclear Information System (INIS)

    Eschenbaum, R.A.

    1981-01-01

    The Hot Cell Verification Facility (HCVF) was established as the test facility for the Fuels and Materials Examination Facility (FMEF) examination equipment. HCVF provides a prototypic hot cell environment to check the equipment for functional and remote operation. It also provides actual hands-on training for future FMEF Operators. In its two years of operation, HCVF has already provided data to make significant changes in items prior to final fabrication. It will also shorten the startup time in FMEF since the examination equipment will have been debugged and operated in HCVF

  16. Assisted Living Facilities - CARE_LONG_TERM_FACILITIES_ISDH_IN: Residential Care Facilities, Nursing Homes, and Hospices in Indiana in 2007 (Indiana State Department of Health, Point Shapefile)

    Data.gov (United States)

    NSGIC State | GIS Inventory — CARE_LONG_TERM_FACILITIES_ISDH_IN is a point shapefile showing the locations of 86 residential care facilities, 525 long-term care facilities (nursing homes), and 81...

  17. Environmental restoration plan for the transfer of surplus facilities to the Facility Transition Program at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1995-08-01

    This report will provide guidance on management, coordination, and integration of plans to transition facilities to the Facility Transition Program and activities as related to the Oak Ridge National Laboratory (ORNL) Environmental Restoration Program facilities. This report gives (1) guidance on the steps necessary for identifying ORNL surplus facilities, (2) interfaces of Surveillance and Maintenance (S and M) and Isotope Facility Deactivation program managers, (3) roles and responsibilities of the facility managers, and (4) initial S and M requirements upon acceptance into the Facility Transition Program

  18. EPA Facility Registry Service (FRS): NCDB

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  19. EPA Facility Registry Service (FRS): BRAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  20. EPA Facility Registry Service (FRS): BIA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  1. EPA Facility Registry Service (FRS): RADINFO

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  2. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  3. EPA Facility Registry Service (FRS): TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  4. EPA Facility Registry Service (FRS): ICIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  5. EPA Facility Registry Service (FRS): RBLC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  6. EPA Facility Registry System (FRS): NCES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  7. EPA Facility Registry Service (FRS): NEI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  8. EPA Facility Registry Service (FRS): CAMDBS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  9. EPA Facility Registry System (FRS): NEPT

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  10. 48 CFR 970.3770 - Facilities management.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Facilities management. 970... REGULATIONS DOE MANAGEMENT AND OPERATING CONTRACTS Facilities Management Contracting 970.3770 Facilities management. ...

  11. EPA Facility Registry Service (FRS): SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  12. EPA Facility Registry Service (FRS): RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  13. 33-GVA interrupter test facility

    International Nuclear Information System (INIS)

    Parsons, W.M.; Honig, E.M.; Warren, R.W.

    1979-01-01

    The use of commercial ac circuit breakers for dc switching operations requires that they be evaluated to determine their dc limitations. Two 2.4-GVA facilities have been constructed and used for this purpose at LASL during the last several years. In response to the increased demand on switching technology, a 33-GVA facility has been constructed. Novel features incorporated into this facility include (1) separate capacitive and cryogenic inductive energy storage systems, (2) fiber-optic controls and optically-coupled data links, and (3) digital data acquisition systems. Facility details and planned tests on an experimental rod-array vacuum interrupter are presented

  14. Facility Interface Capability Assessment (FICA) project report

    International Nuclear Information System (INIS)

    Pope, R.B.; MacDonald, R.R.; Viebrock, J.M.; Mote, N.

    1995-09-01

    The US Department of Energy's (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is responsible for developing the Civilian Radioactive Waste Management System (CRWMS) to accept spent nuclear fuel from commercial facilities. The objective of the Facility Interface Capability Assessment (FICA) project was to assess the capability of each commercial spent nuclear fuel (SNF) storage facility, at which SNF is stored, to handle various SNF shipping casks. The purpose of this report is to present and analyze the results of the facility assessments completed within the FICA project. During Phase 1, the data items required to complete the facility assessments were identified and the database for the project was created. During Phase 2, visits were made to 122 facilities on 76 sites to collect data and information, the database was updated, and assessments of the cask-handling capabilities at each facility were performed. Each assessment of cask-handling capability contains three parts: the current capability of the facility (planning base); the potential enhanced capability if revisions were made to the facility licensing and/or administrative controls; and the potential enhanced capability if limited physical modifications were made to the facility. The main conclusion derived from the planning base assessments is that the current facility capabilities will not allow handling of any of the FICA Casks at 49 of the 122 facilities evaluated. However, consideration of potential revisions and/or modifications showed that all but one of the 49 facilities could be adapted to handle at least one of the FICA Casks. For this to be possible, facility licensing, administrative controls, and/or physical aspects of the facility would need to be modified

  15. Facility Interface Capability Assessment (FICA) project report

    Energy Technology Data Exchange (ETDEWEB)

    Pope, R.B. [ed.] [Oak Ridge National Lab., TN (United States); MacDonald, R.R. [ed.] [Civilian Radioactive Waste Management System, Vienna, VA (United States); Viebrock, J.M.; Mote, N. [Nuclear Assurance Corp., Norcross, GA (United States)

    1995-09-01

    The US Department of Energy`s (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is responsible for developing the Civilian Radioactive Waste Management System (CRWMS) to accept spent nuclear fuel from commercial facilities. The objective of the Facility Interface Capability Assessment (FICA) project was to assess the capability of each commercial spent nuclear fuel (SNF) storage facility, at which SNF is stored, to handle various SNF shipping casks. The purpose of this report is to present and analyze the results of the facility assessments completed within the FICA project. During Phase 1, the data items required to complete the facility assessments were identified and the database for the project was created. During Phase 2, visits were made to 122 facilities on 76 sites to collect data and information, the database was updated, and assessments of the cask-handling capabilities at each facility were performed. Each assessment of cask-handling capability contains three parts: the current capability of the facility (planning base); the potential enhanced capability if revisions were made to the facility licensing and/or administrative controls; and the potential enhanced capability if limited physical modifications were made to the facility. The main conclusion derived from the planning base assessments is that the current facility capabilities will not allow handling of any of the FICA Casks at 49 of the 122 facilities evaluated. However, consideration of potential revisions and/or modifications showed that all but one of the 49 facilities could be adapted to handle at least one of the FICA Casks. For this to be possible, facility licensing, administrative controls, and/or physical aspects of the facility would need to be modified.

  16. Advanced reactor experimental facilities

    International Nuclear Information System (INIS)

    Amri, A.; Papin, J.; Uhle, J.; Vitanza, C.

    2010-01-01

    For many years, the NEA has been examining advanced reactor issues and disseminating information of use to regulators, designers and researchers on safety issues and research needed. Following the recommendation of participants at an NEA workshop, a Task Group on Advanced Reactor Experimental Facilities (TAREF) was initiated with the aim of providing an overview of facilities suitable for carrying out the safety research considered necessary for gas-cooled reactors (GCRs) and sodium fast reactors (SFRs), with other reactor systems possibly being considered in a subsequent phase. The TAREF was thus created in 2008 with the following participating countries: Canada, the Czech Republic, Finland, France, Germany, Hungary, Italy, Japan, Korea and the United States. In a second stage, India provided valuable information on its experimental facilities related to SFR safety research. The study method adopted entailed first identifying high-priority safety issues that require research and then categorizing the available facilities in terms of their ability to address the safety issues. For each of the technical areas, the task members agreed on a set of safety issues requiring research and established a ranking with regard to safety relevance (high, medium, low) and the status of knowledge based on the following scale relative to full knowledge: high (100%-75%), medium (75 - 25%) and low (25-0%). Only the issues identified as being of high safety relevance and for which the state of knowledge is low or medium were included in the discussion, as these issues would likely warrant further study. For each of the safety issues, the TAREF members identified appropriate facilities, providing relevant information such as operating conditions (in- or out-of reactor), operating range, description of the test section, type of testing, instrumentation, current status and availability, and uniqueness. Based on the information collected, the task members assessed prospects and priorities

  17. Decommissioning engineering systems for nuclear facilities and knowledge inheritance for decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo

    2016-01-01

    Information on construction, operation and maintenance of a nuclear facility is essential in order to plan and implement the decommissioning of the nuclear facility. A decommissioning engineering system collects these information efficiently, retrieves necessary information rapidly, and support to plan the reasonable decommissioning as well as the systematic implementation of dismantling activities. Then, knowledge of workers involved facility operation and dismantling activities is important because decommissioning of nuclear facility will be carried out for a long period. Knowledge inheritance for decommissioning has been carried out in various organizations. This report describes an outline of and experiences in applying decommissioning engineering systems in JAEA and activities related to knowledge inheritance for decommissioning in some organizations. (author)

  18. EPA Facility Registry Service (FRS): OIL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil...

  19. 340 waste handling facility interim safety basis

    Energy Technology Data Exchange (ETDEWEB)

    VAIL, T.S.

    1999-04-01

    This document presents an interim safety basis for the 340 Waste Handling Facility classifying the 340 Facility as a Hazard Category 3 facility. The hazard analysis quantifies the operating safety envelop for this facility and demonstrates that the facility can be operated without a significant threat to onsite or offsite people.

  20. 340 waste handling facility interim safety basis

    International Nuclear Information System (INIS)

    VAIL, T.S.

    1999-01-01

    This document presents an interim safety basis for the 340 Waste Handling Facility classifying the 340 Facility as a Hazard Category 3 facility. The hazard analysis quantifies the operating safety envelop for this facility and demonstrates that the facility can be operated without a significant threat to onsite or offsite people

  1. 340 Facility maintenance implementation plan

    International Nuclear Information System (INIS)

    1995-03-01

    This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the 340 Facility. This plan is developed from the guidelines presented by Department of Energy (DOE) Order 4330.4B, Maintenance Management Program (DOE 1994), Chapter II. The objective of this plan is to provide baseline information for establishing and identifying Westinghouse Hanford Company (WHC) conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at the 340 Facility. Primary responsibility for the performance and oversight of maintenance activities at the 340 Facility resides with Westinghouse Hanford Company (WHC). Maintenance at the 340 Facility is performed by ICF-Kaiser Hanford (ICF-KH) South Programmatic Services crafts persons. This 340 Facility MIP provides interface requirements and responsibilities as they apply specifically to the 340 Facility. This document provides an implementation schedule which has been developed for items considered to be deficient or in need of improvement. The discussion sections, as applied to implementation at the 340 Facility, have been developed from a review of programs and practices utilizing the graded approach. Biennial review and additional reviews are conducted as significant programmatic and mission changes are made. This document is revised as necessary to maintain compliance with DOE requirements

  2. 340 Facility maintenance implementation plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the 340 Facility. This plan is developed from the guidelines presented by Department of Energy (DOE) Order 4330.4B, Maintenance Management Program (DOE 1994), Chapter II. The objective of this plan is to provide baseline information for establishing and identifying Westinghouse Hanford Company (WHC) conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at the 340 Facility. Primary responsibility for the performance and oversight of maintenance activities at the 340 Facility resides with Westinghouse Hanford Company (WHC). Maintenance at the 340 Facility is performed by ICF-Kaiser Hanford (ICF-KH) South Programmatic Services crafts persons. This 340 Facility MIP provides interface requirements and responsibilities as they apply specifically to the 340 Facility. This document provides an implementation schedule which has been developed for items considered to be deficient or in need of improvement. The discussion sections, as applied to implementation at the 340 Facility, have been developed from a review of programs and practices utilizing the graded approach. Biennial review and additional reviews are conducted as significant programmatic and mission changes are made. This document is revised as necessary to maintain compliance with DOE requirements.

  3. Reflooding phenomena of German PWR estimated from CCTF [Cylindrical Core Test Facility], SCTF [Slab Core Test Facility] and UPTF [Upper Plenum Test Facility] results

    International Nuclear Information System (INIS)

    Murao, Y.; Iguchi, T.; Sugimoto, J.

    1988-09-01

    The reflooding behavior in a PWR with a combined injection type ECCS was studied by comparing the test results from Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF) and Upper Plenum Test Facility (UPTF). Core thermal-hydraulics is discussed mainly based on SCTF test data. In addition, the water accumulation behavior in hot legs and the break-through characteristics at tie plate are discussed

  4. EPA Facility Registry Service (FRS): ER_FRP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to Facility...

  5. Hot cell verification facility update

    International Nuclear Information System (INIS)

    Titzler, P.A.; Moffett, S.D.; Lerch, R.E.

    1985-01-01

    The Hot Cell Verification Facility (HCVF) provides a prototypic hot cell mockup to check equipment for functional and remote operation, and provides actual hands-on training for operators. The facility arrangement is flexible and assists in solving potential problems in a nonradioactive environment. HCVF has been in operation for six years, and the facility is a part of the Hanford Engineering Development Laboratory

  6. XRD alignment, calibration and performance

    International Nuclear Information System (INIS)

    Davy, L.

    2002-01-01

    Full text: The quality of any diffractometer system is very much dependent on the alignment, calibration and performance. The three subjects are very much related. Firstly, you must know how to carry out the full diffractometer alignment. XRD alignment is easy once you know how. The presentation will show you step by step to carry out the full alignment. Secondly, you need to know how to calibrate the diffractometer system. The presentation will show you how to calibrate the goniometer, detector etc. Thirdly, to prove the system is working within the manufacturer specification. The presentation will show you how to carry out the resolution, reproducibility and linearity test. Copyright (2002) Australian X-ray Analytical Association Inc

  7. Improvement of irradiation facilities performance in JMTR

    International Nuclear Information System (INIS)

    Kanno, Masaru; Sakurai, Susumu; Honma, Kenzo; Sagawa, Hisashi; Nakazaki, Chousaburo

    1999-01-01

    Various kinds of irradiation facilities are installed in the JMTR for the purpose of irradiation tests on fuels and materials and of producing radioisotopes. The irradiation facilities have been improved so far at every opportunity of new irradiation requirements and of renewing them which reached the design lifetime. Of these irradiation facilities, improvements of the power ramping test facility (BOCA/OSF-1 facility) and the hydraulic rabbit No.2 (HR-2 facility) are described here. (author)

  8. Safety of nuclear fuel cycle facilities. Safety requirements

    International Nuclear Information System (INIS)

    2008-01-01

    This publication covers the broad scope of requirements for fuel cycle facilities that, in light of the experience and present state of technology, must be satisfied to ensure safety for the lifetime of the facility. Topics of specific reference include aspects of nuclear fuel generation, storage, reprocessing and disposal. Contents: 1. Introduction; 2. The safety objective, concepts and safety principles; 3. Legal framework and regulatory supervision; 4. The management system and verification of safety; 5. Siting of the facility; 6. Design of the facility; 7. Construction of the facility; 8. Commissioning of the facility; 9. Operation of the facility; 10. Decommissioning of the facility; Appendix I: Requirements specific to uranium fuel fabrication facilities; Appendix II: Requirements specific to mixed oxide fuel fabrication facilities; Appendix III: Requirements specific to conversion facilities and enrichment facilities

  9. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  10. Classified facilities for environmental protection

    International Nuclear Information System (INIS)

    Anon.

    1993-02-01

    The legislation of the classified facilities governs most of the dangerous or polluting industries or fixed activities. It rests on the law of 9 July 1976 concerning facilities classified for environmental protection and its application decree of 21 September 1977. This legislation, the general texts of which appear in this volume 1, aims to prevent all the risks and the harmful effects coming from an installation (air, water or soil pollutions, wastes, even aesthetic breaches). The polluting or dangerous activities are defined in a list called nomenclature which subjects the facilities to a declaration or an authorization procedure. The authorization is delivered by the prefect at the end of an open and contradictory procedure after a public survey. In addition, the facilities can be subjected to technical regulations fixed by the Environment Minister (volume 2) or by the prefect for facilities subjected to declaration (volume 3). (A.B.)

  11. Fuel Handling Facility Description Document

    International Nuclear Information System (INIS)

    M.A. LaFountain

    2005-01-01

    The purpose of the facility description document (FDD) is to establish the requirements and their bases that drive the design of the Fuel Handling Facility (FHF) to allow the design effort to proceed to license application. This FDD is a living document that will be revised at strategic points as the design matures. It identifies the requirements and describes the facility design as it currently exists, with emphasis on design attributes provided to meet the requirements. This FDD was developed as an engineering tool for design control. Accordingly, the primary audience and users are design engineers. It leads the design process with regard to the flow down of upper tier requirements onto the facility. Knowledge of these requirements is essential to performing the design process. It trails the design with regard to the description of the facility. This description is a reflection of the results of the design process to date

  12. Modern techniques of structural neutron diffraction

    International Nuclear Information System (INIS)

    Aksenov, V.L.; )

    1997-01-01

    Modern techniques of neutron diffraction for structural investigations are analyzed. The time-of-flight method and the reverse time-of-flight method are considered briefly. Characteristics of two-crystal and time-of-flight neutron diffractometers are compared. It is pointed that in the future, the great importance will be possessed the development of high-resolution Fourier neutron diffractometers [ru

  13. Strategic facility planning improves capital decision making.

    Science.gov (United States)

    Reeve, J R

    2001-03-01

    A large, Midwestern IDS undertook a strategic facility-planning process to evaluate its facility portfolio and determine how best to allocate future investments in facility development. The IDS assembled a facility-planning team, which initiated the planning process with a market analysis to determine future market demands and identify service areas that warranted facility expansion. The team then analyzed each of the IDS's facilities from the perspective of uniform capacity measurements, highest and best use compared with needs, building condition and investment-worthiness, and facility growth and site development opportunities. Based on results of the analysis, the strategy adopted entailed, in part, shifting some space from inpatient care to ambulatory care services and demolishing and replacing the 11 percent of facilities deemed to be in the worst condition.

  14. Facility or Facilities? That is the Question.

    Science.gov (United States)

    Viso, M.

    2018-04-01

    The management of the martian samples upon arrival on the Earth will require a lot of work to ensure a safe life detection and biohazard testing during the quarantine. This will induce a sharing of the load between several facilities.

  15. Eccentric Coil Test Facility (ECTF)

    International Nuclear Information System (INIS)

    Burn, P.B.; Walstrom, P.L.; Anderson, W.C.; Marguerat, E.F.

    1975-01-01

    The conceptual design of a facility for testing superconducting coils under some conditions peculiar to tokamak systems is given. A primary element of the proposed facility is a large 25 MJ background solenoid. Discussions of the mechanical structure, the stress distribution and the thermal stability for this coil are included. The systems for controlling the facility and diagnosing test coil behavior are also described

  16. Facility effluent monitoring plan for the Waste Receiving and Processing Facility Module 1

    International Nuclear Information System (INIS)

    Lewis, C.J.

    1995-10-01

    A facility effluent monitoring plan is required by the US Department of Energy in Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal state, and local requirements. This facility effluent monitoring plan shall ensure lonq-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years

  17. Evaluation of existing United States' facilities for use as a mixed-oxide (MOX) fuel fabrication facility for plutonium disposition

    International Nuclear Information System (INIS)

    Beard, C.A.; Buksa, J.J.; Chidester, K.; Eaton, S.L.; Motley, F.E.; Siebe, D.A.

    1995-01-01

    A number of existing US facilities were evaluated for use as a mixed-oxide fuel fabrication facility for plutonium disposition. These facilities include the Fuels Material Examination Facility (FMEF) at Hanford, the Washington Power Supply Unit 1 (WNP-1) facility at Hanford, the Barnwell Nuclear Fuel Plant (BNFP) at Barnwell, SC, the Fuel Processing Facility (FPF) at Idaho National Engineering Laboratory (INEL), the Device Assembly Facility (DAF) at the Nevada Test Site (NTS), and the P-reactor at the Savannah River Site (SRS). The study consisted of evaluating each facility in terms of available process space, available building support systems (i.e., HVAC, security systems, existing process equipment, etc.), available regional infrastructure (i.e., emergency response teams, protective force teams, available transportation routes, etc.), and ability to integrate the MOX fabrication process into the facility in an operationally-sound manner that requires a minimum amount of structural modifications

  18. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  19. Sports Facilities Development and Urban Generation

    OpenAIRE

    Maassoumeh Barghchi; Dasimah B.   Omar; Mohd S.   Aman

    2009-01-01

    Problem statement: One major issue on sports facilities construction is the question of their funding and justification for investment. Due to, requirement of huge money for construction, constant maintenance costs and ancillary needs, which are almost certainly with substantial public investment, therefore, sports facilities have been considered. Further, sports facilities construction boom have been started for more than two decades. Approach: Recent sports facilities construction was not p...

  20. Facile Synthesis and Characterization of ZrO₂ Nanoparticles via Modified Co-Precipitation Method.

    Science.gov (United States)

    Ramachandran, M; Subadevi, R; Liu, Wei-Ren; Sivakumar, M

    2018-01-01

    The crystalline Zirconium oxide (ZrO2) nano particles were synthesized using optimized content of Zirconium nitrate (Zr(NO3)2·3H2O) with varying KOH concentration (0.5, 1 and 1.5 M) by co-precipitation method. The thermal history of the precursor was carefully analyzed through Thermogravimetric (TG/DTA) measurement. The as prepared samples were characterized to ensure structural, functional, morphological, compositional, chemical composition and band gap by X-ray diffractometer (XRD), Fourier transform infrared spectroscopy (FTIR), Laser Raman, scanning electron microscopy (SEM), High resolution Transverse Electron Microscopy (HR-TEM), X-ray photo electron spectroscopy (XPS), EDX, Photo luminescence spectroscopy (PL). The monoclinic structure with space group P21/c has been confirmed from XRD (JCPDS 89-9066). The Zr-O stretching vibration and Zr-O2-Zr bending vibrations were confirmed through FTIR analysis. The well dispersed particles with spherical morphology were confirmed through SEM and TEM analysis. The oxidation states of Zr, O and C were confirmed through XPS analysis. The oxygen vacancies and band gap of the particles were investigated through PL analysis.