WorldWideScience

Sample records for rsg gas mpr-30

  1. Fuel management strategy for the compact core design of RSG GAS (MPR-30)

    Energy Technology Data Exchange (ETDEWEB)

    Sembiring, T.M.; Liem, P.H.; Tukiran, S. [National Nuclear Energy Agency (Batan), PUSPIPTEK-Serpong Tangerang (Indonesia)

    2000-07-01

    The rearrangement of the core configuration of the RSG GAS reactor to obtain a compact core is in progress. A fuel management strategy is proposed for the equilibrium compact core of this reactor by reducing the number of in-core irradiation positions. The reduced irradiation positions are based on the activities during 12 years operation. The obtained compact core gives significant extension of the operation cycle length so that the reactor availability and utilization can be enhanced. The equilibrium compact silicide core obtained met the imposed design constraints and safety requirements. (author)

  2. Fuel management strategy for the compact core design of RSG GAS (MPR-30)

    International Nuclear Information System (INIS)

    Sembiring, T.M.; Liem, P.H.; Tukiran, S.

    2000-01-01

    The rearrangement of the core configuration of the RSG GAS reactor to obtain a compact core is in progress. A fuel management strategy is proposed for the equilibrium compact core of this reactor by reducing the number of in-core irradiation positions. The reduced irradiation positions are based on the activities during 12 years operation. The obtained compact core gives significant extension of the operation cycle length so that the reactor availability and utilization can be enhanced. The equilibrium compact silicide core obtained met the imposed design constraints and safety requirements. (author)

  3. Recent Status RSG-GAS Ageing Management

    Energy Technology Data Exchange (ETDEWEB)

    Sunaryo, Geni Rina; Setianto; Tarigan, Alim [Puspiptek Area, Serpong (Indonesia); Wisnubroto, D. S. [Mampang Prapatan, Jakarta (Indonesia)

    2013-07-01

    RSG GAS Research Reactor.30 MW, which is the biggest scientific investment made by the Indonesian Government, is operating safely for about 27 years. This research reactor has been built and developed since year 1983. Critical attainment reached first on July 1987 and ceremonial opened by president of RI on August 20{sup th} 1987. Operated with full energy of 30 MW reached first time on March 1992. It started becoming commercially operated since 1995. RSG-GAS has a maximum thermal energy of 30 MW and has neutron flux of averaged 10{sup 14} n/cm{sup 2}.sec coming from fissile reaction. RSG-GAS is a reactor with pool type with fuel of 19.75% enriched U{sub 3}O{sub 8}Al/U{sub 3}Si{sub 2}Al and burned up ratio up to 56%. RSG GAS has been built for scientific purpose by utilizing neutron beam instruments and isotope productions. Facilities allowing Neutron Activation Analysis for research and industry are both on-line. For affording the utilization or the reactor operation approaching the designed life, the progressive ageing management is being applied. This paper will address the ageing management based on the importance to safety and SSC replacement ease consideration, which is implemented on RSG GAS. It consist of minimization of expected ageing prevention which is divided into prevention actions and followed by periodic review of this effectiveness, detection, monitoring and trending of ageing degradation through periodically inspections, and testing. Some activities such as NDT-ultrasonic to mitigating the ageing degradation of secondary water pipe lines, underwater camera for tank liners, infrared thermograph for understanding the cable insulation age, Eddy Current for inspecting the Heat Exchangers, surveillance corrosion for understanding the corrosion mechanism and structure material lifetime by immersing cupons into primary, secondary and raw water basin for many years and some ended by refurbishment-for secondary pump, are being applied. Based on the results

  4. Fuel element burnup measurements for the equilibrium LEU silicide RSG GAS (MPR-30) core under a new fuel management strategy

    International Nuclear Information System (INIS)

    Pinem, Surian; Liem, Peng Hong; Sembiring, Tagor Malem; Surbakti, Tukiran

    2016-01-01

    Highlights: • Burnup measurement of fuel elements comprising the new equilibrium LEU silicide core of RSG GAS. • The burnup measurement method is based on a linear relationship between reactivity and burnup. • Burnup verification was conducted using an in-house, in-core fuel management code BATAN-FUEL. • A good agreement between the measured and calculated burnup was confirmed. • The new fuel management strategy was confirmed and validated. - Abstract: After the equilibrium LEU silicide core of RSG GAS was achieved, there was a strong need to validate the new fuel management strategy by measuring burnup of fuel elements comprising the core. Since the regulatory body had a great concern on the safety limit of the silicide fuel element burnup, amongst the 35 burnt fuel elements we selected 22 fuel elements with high burnup classes i.e. from 20 to 53% loss of U-235 (declared values) for the present measurements. The burnup measurement method was based on a linear relationship between reactivity and burnup where the measurements were conducted under subcritical conditions using two fission counters of the reactor startup channel. The measurement results were compared with the declared burnup evaluated by an in-house in-core fuel management code, BATAN-FUEL. A good agreement between the measured burnup values and the calculated ones was found within 8% uncertainties. Possible major sources of differences were identified, i.e. large statistical errors (i.e. low fission counters’ count rates), variation of initial U-235 loading per fuel element and accuracy of control rod indicators. The measured burnup of the 22 fuel elements provided the confirmation of the core burnup distribution planned for the equilibrium LEU silicide core under the new fuel management strategy.

  5. Fabrication Of Control Rod System Of The RSG-GAS

    International Nuclear Information System (INIS)

    Sudirdjo, Hari; Setyono; Prasetya, Hendra

    2001-01-01

    Eight units of control rod mechanical system of RSG-GAS has been fabricated. The control rod mechanical system of RSG-GAS consist of guide tube and lifting rod. Complete construction of the control rod mechanical system of RSG-GAS are guide tube, lifting rod, absorber, and absorber casing. The eight units of the control rod mechanical system of RSG-GAS has been fabricated according to the mechanical engineering design

  6. The Assesment Of Radioactive Accident Management On The RSG-GAS

    International Nuclear Information System (INIS)

    Soejoedi, Agoes; Karmana, Endang

    2000-01-01

    In the operational reactor facilities include RSG-GAS, safety factor for radioactive accident very important to be prioritized. Till now the anticipate happening radioactive accident on the RSG-GAS threat only by the RSG-GAS Operation Manual. For increasing the working function need to create radioactive accident management by facility level. From studying result which source IAEA guidebook, can be composed the assessment accident management of radioactive the RSG-GAS.The sketching this accident management of radioactive to be hoped can helping P2TRR organization by handling radioactive accident if this moment happen on the RSG-GAS

  7. KARAKTERISTIK REAKTIVITAS TERAS KERJA RSG-GAS SELAMA 30 TAHUN BEROPERASI

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2017-06-01

    Full Text Available RSG-GAS, mulai dari komisioning, operasi teras kerja hingga kini telah 30 tahun beroperasi sehingga perlu dilakukan evaluasi keselamatan parameter neutroniknya. Untuk tujuan keselamatan telah dilakukan berbagai aktivitas penelitian, baik yang berhubungan dengan operasi, keselamatan, maupun dalam rangka penggunaan reaktor. Analisis dan pengelolaan besaran reaktivitas yang menunjang keselamatan operasi reaktor sangat penting dilakukan karena besaran ini mempengaruhi desain, kendali dan jadual operasi reaktor. Besaran tersebut dapat ditentukan melalui pengukuran reaktivitas batang kendali dan eksperimen pemuatan bahan bakar di dalam teras. Pengukuran reaktivitas batang kendali yang dilakukan pada setiap awal siklus teras (dengan kondisi teras dingin dan bersih, bebas pengaruh xenon, menghasilkan nilai reaktivitas batang kendali yang dapat digunakan untuk menentukan nilai reaktivitas lainnya seperti reaktivitas lebih, reaktivitas padam dan reaktivitas total. Pengelolaan reaktivitas teras telah dilakukan dengan baik selama 30 tahun dalam rangka mendukung operasi reaktor untuk keperluan penelitian dan iradiasi target.

  8. Approach to the Aging Management of RSG-GAS

    International Nuclear Information System (INIS)

    Mohammad Dhandhang Purwadi

    2004-01-01

    Safety is an condition which must always reached in management a nuclear reactor, from construction stage, operation until the decommissioning have processed. The safety of reactor operation is closely related to the reliability of components, structures and systems (KSS) of the nuclear reactor. All reactors' KSS will experience of ageing and then degrade system reliability level. G.A. Siwabessy Multipurpose Reactor (RSG-GAS) is high power research reactor which have been operating for sixteen years long. Comprehensive evaluation of ageing process that happened in RSG-GAS has not conducted yet. Meanwhile, in general, for all research reactor type there are safety requirements from IAEA related to the ageing, even in design, development, operation and extending operation life. To starting and racing the comprehensive evaluation of ageing in RSG-GAS, the research to compile an integrated Ageing Management Document as guidance in implementation of ageing management in RSG-GAS was conducted. From result of this research, the Ageing Management Document of RSG-GAS has been compiled. Compilation of the document is carried out by embracing approach of compromise of ageing management of research reactor and power reactor. (author)

  9. Experience in producing LEU fuel elements for the RSG-GAS

    International Nuclear Information System (INIS)

    Suripto, A.; Soentono, S.

    1991-01-01

    To achieve a self-reliance in the operation of the 30 MW Multipurpose Research Reactor at Serpong (the RSG-GAS), a fuel element production facility has been constructed nearby. The main task of the facility is to produce MTR type fuel and control elements containing U 3 O 8 -Al dispersion LEU fuel for the RSG-GAS. The hot commissioning activity has started in early 1988 after completion of the cold commissioning using depleted uranium in 1987, marking the beginning of the real production activity. This paper briefly describes the main features of the fuel production facility, the production experience gained so far, and its current production activity. (orig.)

  10. RSG-GAS. Current and strategic plan of future activities

    Energy Technology Data Exchange (ETDEWEB)

    Antariksawan, Anhar R; Tarigan, A [National Nuclear Energy Agency of Indonesia (BATAN), Jakarta (Indonesia)

    2012-03-15

    The Multi Purpose Reactor G.A. Siwabessy, so-called RSG-GAS, is the third research reactor built in Indonesia and operated by National Nuclear Energy of Indonesia (BATAN). This MTR type reactor achieved its first criticality in July 1987. Since then it has been operated about 77.300 hours. It uses LEU fuel in the form of U{sub 3}O{sub 8}-Al at the beginning, but then converted to silicide fuel, U{sub 3}Si{sub 2}-Al by a density of 2.96 g/cm{sup 3} preserving its nominal power of 30 MW and average flux of 2.5x10{sup 14} n/cm{sup 2} sec. In the last two years the reactor is operated more than 3.500 hours per year. Several equipments have been refurbished due to ageing. The reactor is operated mainly for serving radioisotopes production, neutron activation analysis (NAA), neutron beam experiments and general irradiation for research and development activities. The future activities of the RSG-GAS reactor will be prioritized first on increasing the reliability and availability of the reactor operation to assure the fulfillment of the demand of the isotope production, along with the improvement of neutron beam instruments and NAA facilities to increase its utilization. In this context, the collaboration in the utilization of RSG-GAS for many application with the countries in the region is also expected. The human resource development for the new recruited RSG-GAS staff is also a challenge and become a priority. (author)

  11. Analysis of Neutron Flux Distribution in Rsg-Gas Reactor With U-Mo Fuels

    Directory of Open Access Journals (Sweden)

    Taswanda Taryo

    2004-01-01

    Full Text Available The use of U-Mo fuels in research reactors seems to be promising and, recently, world researchers have carried out these such activities actively. The National Nuclear Energy Agency (BATAN which owns RSG-GAS reactor available in Serpong Research Center for Atomic Energy should anticipate this trend. It is, therefore, this research work on the use of U-Mo fuels in RSG-GAS reactor should be carried out. The work was focused on the analysis of neutron flux distribution in the RSG-GAS reactor using different content of molybdenum in U-Mo fuels. To begin with, RSG-GAS reactor core model was developed and simulated into X, Y and Z dimensions. Cross section of materials based on the developed cells of standard and control fuels was then generated using WIMS-D5-B. The criticality calculations were finally carried out applying BATAN-2DIFF code. The results showed that the neutron flux distribution obtained in U-Mo-fuel-based RSG-GAS core is very similar to those achieved in the 300-gram sillicide-fuel-based RSG-GAS reactor core. Indeed, the utilization of the U-Mo RSG-GAS core can be very similar to that of the high-density sillicide reactor core and even could be better in the future.

  12. Analysis of addition of the safety rods at RSG-GAS core

    International Nuclear Information System (INIS)

    S, Tukiran; S, Tagor Malem; K, Iman

    2002-01-01

    The silicide fuel loading of the RSG-GAS core is planned to increase from 250 gU to 300 gU. Increasing of fuel loading will prolong the operation cycle length from 25 days to 32,5 days, but ability of reactivity compensation by control rods system decreased because the reactivity shut-down margin is available only 1,03 %, expectation is 2.2 %. One of solutions is added two safety control rods in B-3 and G-10 positions the aim of installing two safety rods (BKP) in RSG-GAS core is to increase core safety margin. So before using the safety control rods in the RSG-GAS core, it is necessary to know its performance, one of the tests showing its performance is to measure the reactivity of the safety control rods. Measurement of safety control rods were done to know each reactivity worth of safety control rods at middle cycle so that the safety rod be used in the RSG-GAS core. Measurement done by using calibration control rods with couple compensation method which always using in the RSG-GAS core to measure the existing control rods. The results of measurement showed that two safety rods (BKP01 and BKP02) have reactivity worth of 93.5 cent and 87.5 cent, respectively. the total reactivity worth of safety control rods is 1.38%. So the two safety rods can be used to increase safety margin of the RSG-GAS core if the fuel is exchanged to 300 gU of loading

  13. Reliability Analysis of RSG-GAS Primary Cooling System to Support Aging Management Program

    Science.gov (United States)

    Deswandri; Subekti, M.; Sunaryo, Geni Rina

    2018-02-01

    Multipurpose Research Reactor G.A. Siwabessy (RSG-GAS) which has been operating since 1987 is one of the main facilities on supporting research, development and application of nuclear energy programs in BATAN. Until now, the RSG-GAS research reactor has been successfully operated safely and securely. However, because it has been operating for nearly 30 years, the structures, systems and components (SSCs) from the reactor would have started experiencing an aging phase. The process of aging certainly causes a decrease in reliability and safe performances of the reactor, therefore the aging management program is needed to resolve the issues. One of the programs in the aging management is to evaluate the safety and reliability of the system and also screening the critical components to be managed.One method that can be used for such purposes is the Fault Tree Analysis (FTA). In this papers FTA method is used to screening the critical components in the RSG-GAS Primary Cooling System. The evaluation results showed that the primary isolation valves are the basic events which are dominant against the system failure.

  14. Simulation for temperature changing investigation at RSG-GAS cooling system

    International Nuclear Information System (INIS)

    Utaja

    2002-01-01

    The RSG-GAS cooling system considers of primary and secondary system, is used for heat rejection from reactor core to the atmosphere. For temperature changing investigation cause by atmospherics condition changing or coolant flow rate changing, is more safe done by simulation. This paper describes the simulation for determine the RSG-GAS coolant temperature changing base on heat exchange and cooling tower characteristic. The simulation is done by computer programme running under WINDOWS 95 or higher. The temperature changing is based on heat transfer process on heat exchanger and cooling tower. The simulation will show the water tank temperature changing caused by the temperature and humidity of the atmosphere or by coolant flow rate changing. For example the humidity changing from 60% to 80% atmospherics temperature 30 oC and 32400 k Watt power will change the tank temperature from 37,97 oC to 40,03 oC

  15. Optimalisation Of Oxide Burn-Up Enhanced For RSG-Gas Core

    International Nuclear Information System (INIS)

    Tukiran; Sembiring, Tagor Malem

    2000-01-01

    Strategy of fuel management of the RSG-Gas core has been changed from 6/1 to 5/1 pattern so the evaluation of fuel management is necessary to be done. The aim of evaluation is to look for the optimal fuel management so that the fuel can be stayed longer in the core and finally can save cost of operation. Using Batan-EQUIL-2D code did the evaluation of fuel management with 5/1 pattern. The result of evaluation is used to choose which one is more advantage without break the safety margin which is available in the Safety Analysis Report (SAR) firstly, the fuel management was calculated with core excess reactivity of 9,2% criteria. Secondly, fuel burn-up maximum of 56% criteria and the last, fuel burn-up maximum of 64% criteria. From the result of fuel management calculation of the RSG-Gas equilibrium core can be concluded that the optimal RSG-Gas equilibrium core with 5/1 pattern is if the fuel burn-up maximum 64% and the energy in a cycle of operation is 715 MWD. The fuel can be added one more step in the core without break any safety margin. It means that the RSG-Gas equilibrium core can save fuel and cost reduction

  16. Analysis of reactivity accidents of the RSG-GAS core with silicide fuel

    International Nuclear Information System (INIS)

    Tukiran

    2002-01-01

    The fuels of RSG-GAS reactor is changed from uranium oxide to uranium silicide. For time being, the fuel of RSG-GAS core are mixed up between oxide and silicide fuels with 250 gr of loading and 2.96 g U/cm 3 of density, respectively. While, silicide fuel with 300 gr of loading is still under research. The advantages of silicide fuels are can be used in high density, so that, it can be stayed longer in the core at higher burn-up, therefore, the length of cycle is longer. The silicide fuel in RSG-GAS core is used in step-wise by using mixed up core. Firstly, it is used silicide fuel with 250 gr of loading and then, silicide fuel with 300 gr of loading (3.55 g U/cm 3 of density). In every step-wise of fuel loading must be analysed its safety margin. In this occasion, it is analysed the reactivity accident of RSG-GAS core with 300 gr of silicide fuel loading. The calculation was done by using POKDYN code which available at P2TRR. The calculation was done by reactivity insertion at start up and power rangers. From all cases which were have been done, the results of analysis showed that there is no anomaly and safety margin break at RSG-GAS core with 300 gr silicide fuel loading

  17. Verification for excess reactivity on beginning equilibrium core of RSG GAS

    International Nuclear Information System (INIS)

    Daddy Setyawan; Budi Rohman

    2011-01-01

    BAPETEN is an institution authorized to control the use of nuclear energy in Indonesia. Control for the use of nuclear energy is carried out through three pillars: regulation, licensing, and inspection. In order to assure the safety of the operating research reactors, the assessment unit of BAPETEN is carrying out independent assessment in order to verify safety related parameters in the SAR including neutronic aspect. The work includes verification to the Power Peaking Factor in the equilibrium silicide core of RSG GAS reactor by computational method using MCNP-ORIGEN. This verification calculation results for is 9.4 %. Meanwhile, the RSG-GAS safety analysis report shows that the excess reactivity on equilibrium core of RSG GAS is 9.7 %. The verification calculation results show a good agreement with the report. (author)

  18. NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2016-03-01

    Full Text Available Abstract NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE. Research of UMo fuel for research reactor has been developing  right now. The fuel of  research reactor used is uranium low enrichment with high density. For supporting the development of fuel, an assessment of mini fuel in the RSG-GAS core was performed. The mini fuel are U7Mo-Al and U6Zr-Al with densitis of 7.0gU/cc and 5.2 gU/cc, respectively. The size of both fuel are the same namely 630x70.75x1.30 mm were inserted to the 3 plates of dummy fuel. Before being irradiated in the core, a calculation for safety analysis  from neutronics and thermohydrolics aspects were required. However, in this paper will discuss safety analysis of the U7Mo-Al and U6Zr-Al mini fuels from neutronic point of view.  The calculation was done using WIMSD-5B and Batan-3DIFF code. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. Power density of U7Mo-Al mini fuel bigger than U6Zr-Al fuel.   Key words: mini fuel, neutronics analysis, reactor core, safety analysis   Abstrak ANALISIS NEUTRONIK ELEMEN BAKAR UJI MINI DI TERAS RSG-GAS. Penelitian tentang bahan bakar UMo untuk reaktor riset terus berkembang saat ini. Bahan bakar reaktor riset yang digunakan adalah uranium pengkayaan rendah namun densitas tinggi.  Untuk mendukung pengembangan bahan bakar dilakukan uji elemen bakar mini di teras reakror RSG-GAS dengan tujuan menentukan jumlah siklus di dalam teras sehingga tercapai fraksi bakar maksimum. Bahan bakar yang diuji adalah U7Mo-Al dengan densitas 7,0 gU/cc dan U6Zr-Al densitas 5,2 gU/cc. Ukuran kedua bahan bakar uji tersebut adalah sama 630x70,75x1,30 mm dimasukkan masing masing kedalam 3 pelat dummy bahan bakar. Sebelum diiradiasi ke dalam teras reaktor maka perlu dilakukan perhitungan keselamatan baik secara neutronik maupun termohidrolik. Dalam makalah ini

  19. Evaluation Of Radioactivity Concentration In The Primary Cooling Water System Of The RSG-GAS During Operation With 30% Silicide Fuels

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Udiyani, P.M.; Setiawanto, Anto

    2001-01-01

    The evaluating radioactivity concentration in the primary cooling water of the RSG-GAS during operation with 30% silicide fuels has been performed. The method of the research is sampling of primary cooling water during operation of the reactor and calculation of its radioactivity concentration. Based on the data obtained from calculation, the identified nuclides in the water are, Mn-56, Sb-124, Sb-122 and Na-24, under the limit of safety value

  20. Neutronics analysis on mini test fuel in the RSG-GAS core

    International Nuclear Information System (INIS)

    Tukiran S; Tagor M Sembiring

    2016-01-01

    Research on UMo fuel for research reactor has been developed. The fuel of research reactor is uranium molybdenum low enrichment with high density. For supporting the development of fuel fabrication, an neutronic analysis of mini fuel plates in the RSG-GAS core was performed. The aim of analysis is to determine the numbers of fuel cycles in the core to know the maximum fuel burn-up. The mini fuel plates of U_7Mo-Al and U_6Zr-Al with densities of 7.0 gU/cc and 5.2 gU/cc, respectively, will be irradiated in the RSG-GAS core. The size of both fuels, namely 630 x 70.75 x 1.30 mm were inserted to the 3 plates of dummy fuel. Before the fuel will be irradiated in the core, a calculation for safety analysis from neutronics and thermal-hydraulics aspects were required. However, in this paper, it will be discussed safety analysis of the U_7Mo-Al and U_6Zr-Al mini fuels from neutronic point of view. The calculation was done using WIMSD-5B and Batan-3DIFF codes. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. If it is compared, the power density of U_7Mo-Al mini fuel is bigger than U_6Zr-Al fuel. (author)

  1. The Assessment of RSG-GAS Operation by Using Two Transformers

    International Nuclear Information System (INIS)

    Marsahala, Yan Bony

    2007-01-01

    These papers discussed the possibility to use only 2 of 3 units of transformers BHT for reactor operation power supply of RSG-GAS. The basic idea is that the maximum power loaded by electrical system for RSG-GAS is only 1994 KVA and the power supplied by PLN is 3000 KVA. It means, by using two units of transformers, with each capacity of 1500 KVA, are quite sufficient. The problems are the electric power distribution system of RSG-GAS was designed for three distribution lines. Therefore, the modifications of the circuit for power distribution boards BHA, BHB and BHC are required. The assessment results showed that the modification can be carried out by changing the distribution circuit mode on primary side becomes ring system by adding the coupler between two bus bars. So, the possibilities to use 2 of 3 units of transformer for reactor operation are reasonable to be considered. (author)

  2. Verification to the RSG-GAS fuel discharge burn-up using SRAC2006 module of COREBN/HIST

    International Nuclear Information System (INIS)

    J-Susilo; T-M-Sembiring; G-R-Sunaryo; M-Imron

    2018-01-01

    For 30 years operation, some of the modifications to the RSG GAS core has been done, that are changes included the type of fuel from U 3 O 8 -Al to U 3 Si 2 -Al with the same density 2.96 gU/cc, the loading pattern of standard fuel elements/fuel control elements from 6/1 & 6/2 to 5/1 pattern, and in core fuel management calculation tool has been change from IAFUEL to BATAN-FUEL. To obtain an extension of the operating license for the next 10 years, the RSG-GAS Periodic Safety Assessment Document is need to prepared. According to the Regulatory Body Chairman Regulation No. 2 2015, RSG-GAS safety assessment should be done independently. As part of this assessment the fuel discharge burn-up must be estimated. In this research, to ensure that the misposition of fuel element in the core has not occurred, the investigation to the document operating report related the fuel placement has been done. Therefore, by using 78 th to 93 rd operation data, verify of the fuel discharge burn-up of the RSG-GAS has been performed by using SRAC2006 module of COREBN/HIST. In addition, the results of these calculations are also made comparative with the operating report data that is calculated by using BATAN-FUEL. Maximum fuel discharge burn-up (57.73 % of U-235) was verified still under permissible value determined by the regulatory body (<60 % of U-235). Maximum differences value between two computer codes was about 2.12 % of U-235 (3.80 %) that is fuel at the B-7 position. Fuel discharge burn-up of RSG-GAS showed almost the same value for each the operation cycle, range of 1.52 % of U-235. So it can be concluded that the RSG-GAS core operation over the last ten years was in good fuel management performance, in accordance with the design. BATAN-FUEL has been conformed well enough with COREBN/HIST. (author)

  3. Development of Quality Insurance Information System of the RSG-GAS

    International Nuclear Information System (INIS)

    Pranto Busono; Thantawi Nurhapy; Rofei, A.; Rohadi; Warsono; Endang Karmana

    2004-01-01

    To support operation of the RSG-GAS reactor safety, trade on high utilizable, an information system is needed which is easy to accessed, complete and information maintained. For above necessity, data base system for procedure in UJM using MS Access program has been made. MS Access has fields: title, identification number, revision, division, target of and procedure situation. System data base has been test drive successfully properly. It is easy to be accessed the needed information of RSG-GAS with data base system available. (author)

  4. FUEL BURN-UP CALCULATION FOR WORKING CORE OF THE RSG-GAS RESEARCH REACTOR AT BATAN SERPONG

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2017-12-01

    Full Text Available The neutronic parameters are required in the safety analysis of the RSG-GAS research reactor. The RSG-GAS research reactor, MTR (Material Testing Reactor type is used for research and also in radioisotope production. RSG-GAS has been operating for 30 years without experiencing significant obstacles. It is managed under strict requirements, especially fuel management and fuel burn-up calculations. The reactor is operated under the supervision of the Regulatory Body (BAPETEN and the IAEA (International Atomic Energy Agency. In this paper, the experience of managing RSG-GAS core fuels will be discussed, there are hundred possibilities of fuel placements on the reactor core and the strategy used to operate the reactor will be crucial. However, based on strict calculation and supervision, there is no incorrect placement of the fuels in the core. The calculations were performed on working core by using the WIMSD-5B computer code with ENDFVII.0 data file to generate the macroscopic cross-section of fuel and BATAN-FUEL code were used to obtain the neutronic parameter value such as fuel burn-up fractions. The calculation of the neutronic core parameters of the RSG-GAS research reactor was carried out for U3Si2-Al fuel, 250 grams of mass, with an equilibrium core strategy. The calculations show that on the last three operating cores (T90, T91, T92, all fuels meet the safety criteria and the fuel burn-up does not exceed the maximum discharge burn-up of 59%. Maximum fuel burn-up always exists in the fuel which is close to the position of control rod.

  5. Analysis of calculated neutron flux response at detectors of G.A. Siwabessy multipurpose reactor (RSG-GAS Reactor)

    International Nuclear Information System (INIS)

    Taryo, Taswanda

    2002-01-01

    Multi Purpose Reactor G.A. Siwabessy (RSG-GAS) reactor core possesses 4 fission-chamber detectors to measure intermediate power level of RSG-GAS reactor. Another detector, also fission-chamber detector, is intended to measure power level of RSG-GAS reactor. To investigate influence of space to the neutron flux values for each detector measuring intermediate and power levels has been carried out. The calculation was carried out using combination of WIMS/D4 and CITATION-3D code and focused on calculation of neutron flux at different detector location of RSG-GAS typical working core various scenarios. For different scenarios, all calculation results showed that each detector, located at different location in the RSG-GAS reactor core, causes different neutron flux occurred in the reactor core due to spatial time effect

  6. The determination of frequency response function of the RSG Gas by laplace transform analysis

    International Nuclear Information System (INIS)

    Tukiran, S.; Surian, P.; Jujuratisbela, U.

    1997-01-01

    The response function of the RSG-GAS reactor system to the reactivity perturbations is necessary to be analyzed due to the interrelation with reliability and safety of reactor operation. the response depends on the power frequency response function H(s), while H(s) depends on the zero power frequency response function Z(s) and dynamic power coefficient of reactivity Kp(s) determination of the frequency response function of the RSG-GAS reactor was done by Fourier transform analysis method. Z(s) was obtained by fourier transform of P(t) and Cj(t) became P(S) and Cj(s) in point kinetic equations. Second order of simpson rule was used for completion of its numerical integration. then. LYMPR (Laplace transform for multipurpose reactor) code was made with fortran 77 computer language in vax 8550 system. the LTMPR code is able to determine the frequency response function and period-reactivity relation of RSG-GAS reactor by rod drop method. Profile of power as rod drop, zero power (without reactivity feedback) was used for determination frequency response of RSG-GAS reactor. The results of calculations are in a good agreement with experiment result, so the LTMPR code can be used for analysis response frequency of the RSG-GAS reactor

  7. Evaluation Of RSG-GAS Power Installed After 12 Years

    International Nuclear Information System (INIS)

    Mrsahala, Yan Bony

    2001-01-01

    The total power installed in RSG-GAS electric system less then 3 x 2500 KVA. Some of powers installed included are the never used loads, so the operationally total load installed that regularly operational and incidental are amount about 3700 KVA. In this condition, the capacity of power transformer installed 3 x 2500 KVA becomes larger. The influences of the numinous power are electric bill payment by RSG-GAS. The reduces power installed may be done as well as remember that some of the load not be operation so that the power consume for that facility could be cut off. The evaluation and calculation result gives some alternatively can be selected to minimize the electric bill payment

  8. Application of Arma Technique For Operation Stability of RSG-Gas

    International Nuclear Information System (INIS)

    Djudjuratisbela, Udju

    2000-01-01

    Application Of Arma Technique For Operation Stability Of RSG-Gas. Application of Fast Fourier Transport (FFT) method in the noise experiments data had been conducted to reactor kinetic parameter determination of RSG-Gas. Reactor stability that has closed relation to operation safety has not been measured yet. Noise analysis method and ARMA (Auto Regressive Moving Average) technique that has capability to identify mathematical model of the noise experimental data can be used for determination of kinetic/dynamic characteristic equation and its roots. From the roots of reactor characteristic equation, magnitude of natural frequency (fn), damping ratio (xi), damping frequency (fd), decay ratio (delta) and then reactor stability can be calculated

  9. The Evaluation of personnel radiation dose and society radiation on RSG-GAS around as proposal determination of ALARA value

    International Nuclear Information System (INIS)

    Pande Made Udiyani; Puradwi IW

    2007-01-01

    Each nuclear installation to achieve radiation safety has to meet the ALARA concepts. The ALARA value of a nuclear installation should be enacted by regulator body. ALARA value can be determined by evaluation radiation exposure and dose acceptance of nuclear installation operation. As case study in Indonesia, ALARA assessment in nuclear installation is done at RSG-GAS reactor. Intention of this research is to determine gyration reference assess ALARA by evaluate radiation dose acceptance by RSG-GAS radiation personnel and the influence of RSG-GAS operation to presentation of radiation accepted by society which living around its. ALARA of RSG-GAS determined based on evaluation of measurement data of the radiation doses which is accepted by personnel radiation. While evaluation of radiation doses which is accepted by society in the radius 5 km of the RSG-GAS conducted to data result of calculation using program package of CAP-88 and measurement result with method of carborne survey. Result of radiation dose evaluation obtained which not pass dose definition for the radiation worker that is 50 mSv/year, and for society around RSG-GAS that is 5 mSv/year. Based on the result of evaluation hence obtained value of ALARA for RSG-GAS in value of gyration 17 - 50 mSv/year. (author)

  10. Evaluation of the RSG-GAS cooling tower performance

    International Nuclear Information System (INIS)

    Suroso

    2003-01-01

    Utilization of RSG-GAS reactor should be operated as efficiently as possible, so that reactor operation planning using one line primary coolant can be anticipated. To analyze the performance of the RSG-GAS cooling tower with one line primary coolant doing by using same data from 10 MW thermal reactor operation. The result were then compare to those achieved using CATHENA code. The results indicated that, for design condition the ratio of water flowrate to air is (L/G) 1.52 and number transfer unit (NTU) is 0.348. For operation condition, the average of L/G and NTU are respectively 1.37 and 0,348. Moreover the results achieved by the code showed that L/G and NTU are respectively 1.35 and 0,302. The performance of cooling tower achieved operation condition and the code results are respectively 91% and 72%. This means that the calculated results are lower than measurement results

  11. The main cooling system of the RSG-GAS: a study of dissabilities

    International Nuclear Information System (INIS)

    Sudiyono

    1999-01-01

    The RSG-GAS has been operating since August 1987 until now. During that period it has been many papers explain the performance and the safety features of the system. Those papers does not mean any think to the system, but the wickednesses of the system. Is still remain stick on it. This paper describes the wickednesses of the RSG-GAS main cooling system with an objective that their will be a corrective action of the management to improve the system so that such wickednesses can be minimized or even be avoided

  12. Modification Of Origen2's Libraries For RSG-Gas

    International Nuclear Information System (INIS)

    Purwadi, Mohammad Dhandhang

    2000-01-01

    The Origen2 code is a versatile computer code for analixing nuclide characteristics in the nuclear materials.the code is used broadly, and the libraries have been adjusted in the conventional reactor types.Today, the code has become the main tool which support nuclear material safeguard programs in PPTRR-BATAN but its library is not adjusted to the conventional reactor types. Today, the code has become the main tool which supports nuclear material safeguard Programs in PPTR-BATAN but its library is not adjusted for RSG-Gas yet. In this work effort to adjust the libraries to RSG-Gas condition was carried out. The nuclides in the libraries are grouped as actinide, fission products, activation product and structure material. Totally, there are 1700 nuclides of ORIGEN2 libraries that must be adjusted.. In this work so far only 80 nuclides have been adjusted

  13. Evaluation of the RSG-GAS Alpha-Beta Aerosol Contaminant Monitor Performance Under Reactor Operation Condition

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Setiawanto, Anto; Sumarno, Yulius

    2000-01-01

    Analysis to evaluate the RSG-GAS alpha-beta aerosol contaminant monitor performance was done. The high potential radiation working area such as in RSG-GAS is important to monitored for personal safety. Further it is necessary to assure that the system monitor is reliable enough under normal conditions as well as emergency condition. The method uses in this analysis are monitoring and comparing with the standard source. The standard course indicator and panel in main control room indicate that the result is 1 x 110 exp 9 Ci/m exp 3. Based on data monitor observation, the RSG-GAS alpha-beta aerosol contaminant monitor system under reactor operation condition has a good enough performance

  14. RELAP5 SIMULATION FOR SEVERE ACCIDENT ANALYSIS OF RSG-GAS REACTOR

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2018-01-01

    SIMULASI RELAP5 UNTUK ANALISIS KECELAKAAN PARAH PADA REAKTOR RSG-GAS. Reaktor riset di dunia diketahui lebih aman dari pada reaktor daya karena desainnya yang lebih sederhana pada teras dan karakteristika operasinya. Namun demikian, potensi bahaya reaktor riset terhadap publik dan lingkungan tidak bisa diabaikan karena beberapa fitur tertentu. Oleh karena itu, level keselamatan reaktor riset harus jelas ditunjukkan dalam Laporan Analisis Keselamatan (LAK dalam bentuk analisis keselamatan yang dilakukan dengan berbagai macam pendekatan dan metode dan didukung dengan alat komputasi. Tujuan penelitian ini adalah untuk mensimulasikan beberapa kecelakaan parah pada reaktor RSG-GAS yang dapat menyebabkan kerusakan bahan bakar untuk memperkuat hasil analisis kecelakaan parah yang sudah ada dalam LAK. Simulation dilakukan dengan program perhitungan RELAP5/SCDAP/Mod3.4 yang memiliki kemampuan untuk memodelkan elemen bahan bakar tipe pelat di RSG-GAS. Tiga kejadian telah disimulasikan yaitu hilangnya aliran primer dan sekunder dengan kegagalan reaktor untuk dipadamkan, tersumbatnya beberapa kanal pendingin bahan bakar pada daya penuh, dan hilangnya aliran primer dan sekunder yang diikuti dengan tersumbatnya beberapa kanal pendingin bahan bakar setelah reaktor padam. Kejadian pertama akan membahayakan pelat bahan bakar dengan naiknya temperatur kelongsong hingga titik lelehnya yaitu 590 °C. Tersumbatnya satu atau beberapa kanal pada satu elemen bahan bakar menyebabkan konsekuensi yang berbeda pada pelat bahan bakar, dimana paling sedikit tersumbatnya 2 kanal akan merusak satu pelat bahan bakar, apalagi tersumbatnya satu elemen bahan bakar. Kombinasi antara hilangnya aliran pendingin primer dan sekunder yang diikuti dengan tersumbatnya satu kanal bahan bakar setelah reaktor dipadamkan menyebabkan naiknya temperatur kelongsong di bawah titik lelehnya yang berarti sirkulasi alam yang terbentuk dan daya yang terus turun cukup untuk mendinginkan elemen bahan bakar. Kata kunci

  15. Diagnosis of the Main Busbar II Panel Components Ageing of RSG-GAS Electrical System by Using Infrared Thermography

    International Nuclear Information System (INIS)

    Teguh Sulistyo; Kiswanto; Roziq Himawan; Ari Satmoko

    2007-01-01

    To support the operation of RSG-GAS safely, the diagnosis of the ageing of main busbar II BHD/BHE/BHF panel components of RSG-GAS electrical system have been done. By using infrared thermography type Thermo Tracer TH9100PM VI/PW VI. The results of the diagnosis showed that some of the components under degradation with various rate. It can cause the system failure. By understanding the components ageing degradation mechanism and performing the preventive and predictive maintenance and safety of RSG-GAS electrical system earlier, the possibility of accident can be avoided. (author)

  16. Analysis Of The Effect Of Fuel Enrichment Error On Neutronic Properties Of The RSG-GAS Core

    International Nuclear Information System (INIS)

    Saragih, Tukiran; Pinem, Surian

    2002-01-01

    The analysis of the fuel enrichment error effect on neutronic properties has been carried out. The fuel enrichment could be improperly done because of wrong fabrication. Therefore it is necessary to analyze the fuel enrichment error effect to determine how many percents the fuel enrichment maximum can be accepted in the core. The analysis was done by simulation method The RSG-GAS core was simulated with 5 standard fuels and 1 control element having wrong enrichment when inserted into the core. Fuel enrichment error was then simulated from 20%, 25% and 30% and the simulation was done using WIMSD/4 and Batan-2DIFF codes. The cross section of core material of the RSG-GAS was generated by WIMSD/4 code in 1-D, X-Y geometry and 10 energy neutron group. Two dimensions, diffusion calculation based on finite element method was done by using Batan-2DIFF code. Five fuel elements and one control element changed the enrichment was finally arranged as a new core of the RSG-Gas reactor. The neutronic properties can be seen from eigenvalues (k eff ) as well as from the kinetic properties based on moderator void reactivity coefficient. The calculated results showed that the error are still acceptable by k eff 1,097 even until 25% fuel enrichment but not more than 25,5%

  17. Operation experience of the Indonesian multipurpose research reactor RSG-GAS

    Energy Technology Data Exchange (ETDEWEB)

    Hastowo, Hudi; Tarigan, Alim [Multipurpose Reactor Center, National Nuclear Energy Agency of the Republic of Indonesia (PRSG-BATAN), Kawasan PUSPIPTEK Serpong, Tangerang (Indonesia)

    1999-08-01

    RSG-GAS is a multipurpose research reactor with nominal power of 30 MW, operated by BATAN since 1987. The reactor is an open pool type, cooled and moderated with light water, using the LEU-MTR fuel element in the form of U{sub 3}O{sub 8}-Al dispersion. Up to know, the reactor have been operated around 30,000 hours to serve the user. The reactor have been utilized to produce radioisotope, neutron beam experiments, irradiation of fuel element and its structural material, and reactor physics experiments. This report will explain in further detail concerning operational experience of this reactor, i.e. reactor operation data, reactor utilization, research program, technical problems and it solutions, plant modification and improvement, and development plan to enhance better reactor operation performance and its utilization. (author)

  18. Operation experience of the Indonesian multipurpose research reactor RSG-GAS

    International Nuclear Information System (INIS)

    Hastowo, Hudi; Tarigan, Alim

    1999-01-01

    RSG-GAS is a multipurpose research reactor with nominal power of 30 MW, operated by BATAN since 1987. The reactor is an open pool type, cooled and moderated with light water, using the LEU-MTR fuel element in the form of U 3 O 8 -Al dispersion. Up to know, the reactor have been operated around 30,000 hours to serve the user. The reactor have been utilized to produce radioisotope, neutron beam experiments, irradiation of fuel element and its structural material, and reactor physics experiments. This report will explain in further detail concerning operational experience of this reactor, i.e. reactor operation data, reactor utilization, research program, technical problems and it solutions, plant modification and improvement, and development plan to enhance better reactor operation performance and its utilization. (author)

  19. Neutronic Analysis of the RSG-GAS Compact Core without CIP Silicide 3.55 g U/cc and 4.8 g U/cc

    International Nuclear Information System (INIS)

    Jati S; Lily S; Tukiran S

    2004-01-01

    Fuel conversion from U 3 O 8 -Al to U 3 Si 2 -Al 2.96 g U/cc density in the RSG-GAS core had done successfully step by step since 36 th core until 44 th core. So that, since the 45 th core until now (48 th core) had been using full of silicide 2.96 g U/cc. Even though utilization program of silicide fuel with high density (3.55 g U/cc and 4.8 g U/cc) and optimize operation of RSG-GAS core under research. Optimalitation of core with increasing operation cycle have been analyzing about compact core. The mean of compact core is the RSG-GAS core with decrease number of IP or CIP position irradiation. In this research, the neutronic calculation to cover RSG-GAS core and RSG-GAS core without CIP that are using U 3 Si 2 -Al 2.96 g U/cc, 3.55 g U/cc and 4.8 g U/cc had done. Two core calculation done at 15 MW power using SRAC-ASMBURN code. The calculation result show that fuel conversion from 2.96 g U/cc density to 3.55 g U/cc and 4.8 g U/cc will increasing cycle length for both RSG-GAS core and RSG-GAS compact core without CIP. However, increasing of excess reactivity exceeded from nominal value of first design that 9.2%. Change of power peaking factor is not show significant value and still less than 1.4. Core fuelled with U 3 Si 2 -Al 4.8 g U/cc density have maximum discharge burn-up which exceeded from licensing value (70%). RSG-GAS compact core without CIP fuelled U 3 Si 2 -Al 2.96 g U/cc have longer cycle operation then RSG-GAS core and fulfil limitation neutronic parameter at the first design value. (author)

  20. Calculation of the RSG-GAS core using computer code citation-3D

    International Nuclear Information System (INIS)

    Taryo, T.; Rokhmadi

    1998-01-01

    Since core reactivity is one of the reactor safety parameters, this R and D has been carried out. To carry out the R and D, the code called WIMSD4 was used respectively for generating cross section and diffusion parameters. The code CITATION was then applied to estimate core reactivity in the RSG-GAS core. To verify the result of the calculation, data and information of the RSG-GAS Typical Working Core Were used. To Prove the codes reliably used, the case of all control elements down in the reactor core and that of all control rods up in the core were applied. The result taking into account those cases showed respectively that K eff are less and greater than unity (K eff eff >1)

  1. Evaluation of the oxide and silicide fuels reactivity in the RSG-GAS core

    International Nuclear Information System (INIS)

    S, Tukiran; M S, Tagor; S, Lily; Pinem, S.

    2000-01-01

    Fuel exchange of The RSG-GAS reactor core from uranium oxide to uranium silicide in the same loading, density, and enrichment, that is, 250 gr, 2.98 gr/cm 3 , and 19.75 % respectively, will be performed in-step wise. In every cycle of exchange with 5/l mode, it is needed to evaluate the parameter of reactor core operation. One of the important operation parameters is fuel reactivity that gives effect to the core reactivity. The experiment was performed at core no. 36, BOC, low power which exist 2 silicide fuels. The evaluation was done based on the RSG-GAS control rod calibration consisting of 40 fuels and 8 control rod.s. From 40 fuels in the core, there are 2 silicide fuels, RI-225/A-9 and RI-224/C-3. For inserting 2 silicide fuels, the reactivity effect to the core must be know. To know this effect , it was performed fuels reactivity experiment, which based on control rod calibration. But in this case the RSG-GAS has no other fresh oxide fuel so that configuration of the RSG-GAS core was rearranged by taking out the both silicide fuels and this configuration is used as reference core. Then silicide fuel RI-224 was inserted to position F-3 replacing the fresh oxide fuel RI-260 so the different reactivity of the fuels is obtained. The experiment result showed that the fuel reactivity change is in amount of 12.85 cent (0.098 % ) The experiment result was compared to the calculation result, using IAFUEL code which amount to 13.49 cent (0.103 %) The result showed that the reactivity change of oxide to silicide fuel is small so that the fuel exchange from uranium oxide to uranium silicide in the first step can be done without any significant change of the operation parameter

  2. Verification of maximum radial power peaking factor due to insertion of FPM-LEU target in the core of RSG-GAS reactor

    Energy Technology Data Exchange (ETDEWEB)

    Setyawan, Daddy, E-mail: d.setyawan@bapeten.go.id [Center for Assessment of Regulatory System and Technology for Nuclear Installations and Materials, Indonesian Nuclear Energy Regulatory Agency (BAPETEN), Jl. Gajah Mada No. 8 Jakarta 10120 (Indonesia); Rohman, Budi [Licensing Directorate for Nuclear Installations and Materials, Indonesian Nuclear Energy Regulatory Agency (BAPETEN), Jl. Gajah Mada No. 8 Jakarta 10120 (Indonesia)

    2014-09-30

    Verification of Maximum Radial Power Peaking Factor due to insertion of FPM-LEU target in the core of RSG-GAS Reactor. Radial Power Peaking Factor in RSG-GAS Reactor is a very important parameter for the safety of RSG-GAS reactor during operation. Data of radial power peaking factor due to the insertion of Fission Product Molybdenum with Low Enriched Uranium (FPM-LEU) was reported by PRSG to BAPETEN through the Safety Analysis Report RSG-GAS for FPM-LEU target irradiation. In order to support the evaluation of the Safety Analysis Report incorporated in the submission, the assessment unit of BAPETEN is carrying out independent assessment in order to verify safety related parameters in the SAR including neutronic aspect. The work includes verification to the maximum radial power peaking factor change due to the insertion of FPM-LEU target in RSG-GAS Reactor by computational method using MCNP5and ORIGEN2. From the results of calculations, the new maximum value of the radial power peaking factor due to the insertion of FPM-LEU target is 1.27. The results of calculations in this study showed a smaller value than 1.4 the limit allowed in the SAR.

  3. Safeguarding subcriticality during loading and shuffling operations in the higher density of the RSG-GAS's silicide core

    International Nuclear Information System (INIS)

    Sembiring, T.M.; Kuntoro, I.

    2003-01-01

    The core conversion program of the RSG-GAS reactor is to convert the all-oxide to all-silicide core. The silicide equilibrium core with fuel meat density of 3.55 gU cm -3 is an optimal core for RSG-GAS reactor and it can significantly increase the operation cycle length from 25 to 32 full power days. Nevertheless, the subcriticality of the shutdown core and the shutdown margin are lower than of the oxide core. Therefore, the deviation of subcriticality condition in the higher silicide core caused by the fuel loading and shuffling error should be reanalysed. The objective of this work is to analyse the sufficiency of the subcriticality condition of the shutdown core to face the worst condition caused by an error during loading and shuffling operations. The calculations were carried out using the 2-dimensional multigroup neutron diffusion code of Batan-FUEL. In the fuel handling error, the calculated results showed that the subcriticality condition of the shutdown higher density silicide equilibrium core of RSG-GAS can be maintained. Therefore, all fuel management steps are fixed in the present reactor operation manual can be applied in the higher silicide equilibrium core of RSG-GAS reactor. (author)

  4. Moment inertia pump analysis used in the Rsg-Gas primary coolant loop under lofa condition

    International Nuclear Information System (INIS)

    Sudarmono; Setiyanto; Dhandhang, P.; Dibyo, S.; Royadi

    1998-01-01

    The moment inertia of primary cooling system analysis under LOFA condition has been done. It is potentially one of limiting design constraints of the RSG-GAS safety because the coolant flow rate reduces very rapidly under LOFA condition due to the low inertia circulation pumps. If a loss of flow accident occurs, the mass flow will decrease rapidly and the heat transfer coefficient between cladding and coolant will also decreases. As a consequence the fuel and cladding temperature will increase. The whole core was represented by the 1/4 sector and divided into 19 subchannels and 40 axial nodes. In the present study, moment inertia of pump analysis for RSG-GAS reactor was performed with COBRA-IV-I subchannel code. As the DNB correlation, W-3 Correlation was selected for base case. The flow and power transients under pump trip accident were determined from experiments. The result above compared with the design data are 75 kg m 2 and 81 Kg m 2 respectively. The result shows that the RSG-GAS requires the inertia more than 75 kg m 2

  5. MV-Switchgear Performance Evaluation of Electrical System at RSG-GAS after by Refunctioning

    International Nuclear Information System (INIS)

    T-Sulsistyo; T-Komarudin; Kiswanto; Y- Andriyanto

    2005-01-01

    Switchgear represents equipment link functioning to decide or connect source ration especial energy of PLN with building RSG-GAS distribution system burden. This system is provided with equipment circuit breaker (PMT) and disconnecting switch (PMS), which aim to the insulation, controlling, and protection electrical system RSG-GAS and equipment. Evaluation Method used by that is by perceiving nominal tension condition, nominal current, performance normal good switchgear in a condition, treatment and also trouble condition and also calculate change temperature effect of electric fire bow. Pursuant to calculation result, for the mean current 800 A, room; chamber temperature 24 o C, tension 24 kV, current disconnection time link to shorten 3 second, obtained temperature of equal to 90.5 o C (T1), and room temperature 40 o C obtained by temperature of equal to 108.5 o C (T2), so that of average temperature equal to 4.63 o C. While for the mean current 1250 A, room temperature 24 o C, tension 24 kV, current disconnection time link to shorten 3 second, obtained temperature equal to 282 o C (T1), and room temperature 40 o C obtained temperature equal to 298 o C (T2), so that average temperature equal to 4.0 o C. Result of evaluation job indicates that switchgear of electrical system RSG-GAS after re-functioning function goodness. (author)

  6. The Accident Analysis Due to Reactivity Insertion of RSG GAS 3.55 g U/cc Silicide Core

    International Nuclear Information System (INIS)

    Endiah Puji-Hastuti; Surbakti, Tukiran

    2004-01-01

    The fuels of RSG-GAS reactor was changed from uranium oxide with 250 g U of loading or 2.96 g U/cc of fuel loading to uranium silicide with the same loading. The silicide fuels can be used in higher density, staying longer in the reactor core and hence having a longer cycle length. The silicide fuel in RSG-GAS core was made up in step-wise by using mixed up core Firstly, it was used silicide fuel with 250 g U of loading and then, silicide fuel with 300 g U of loading (3.55 g U/cc of fuel loading). In every step-wise of fuel loading, it must be analyzed its safety margin. In this occasion, the reactivity accident of RSG-GAS core with 300 g U of silicide fuel loading is analyzed. The calculation was done using EUREKA-2/RR code available at P2TRR. The calculation was done by reactivity insertion at start up and power rangers. The worst case accident is transient due to control rod with drawl failure at start up by means of lowest initial power (0.1 W), either in power range. From all cases which have been done, the results of analysis showed that there is no anomaly and safety margin break at RSG-GAS core with 300 g U silicide fuel loading. (author)

  7. Fabrication of control rod system of RSG-GAS

    International Nuclear Information System (INIS)

    Hari-Sudirdjo; Setyono; Hendra-Prasetya

    2003-01-01

    Two unit absorbers, they are part of RSG-GAS control rod system, have been fabricated. One set absorber consist of two absorber plates and absorber casing. Absorber plate is made of Ag In Cd ( 80%, 15%, 5% ) alloy, which is cladded by stainless steel plate SS-316. Ag In Cd absorber plate has size of 625 mm x 60 mm x 3.3 mm, while cladding plat has thickness of 0.8 mm. Fabrication of two set absorbers has been conducted according to the plan

  8. Evaluation of RSG-GAS purification system and pool warm water layer supplier performance

    International Nuclear Information System (INIS)

    Sudiyono; Suhadi; Diah-Erlina-Lestari

    2005-01-01

    Function of RSG-GAS purification system and warm water supplier (KBE 02) are to pick up dissolve activation result and another dirts of warm water layer. To keep quality of water at the decided level. The system is equipped by heater to supply warm water layer on the reactor pool surface the distribution is to reduce radiation level in the operation hall area a speciality on the reactor pool surface. Line KBE 02 tomord beam tube headitty system supplies water necessary to be shielding to beam tube in use off time. Of the RSG-GAS purification system and pool warm water layer performance date can be shown north of water is always in good condition. To require the dechded requirement. Resin live time is two years and then months

  9. Neutronic Analysis and Radiological Safety of RSG-GAS Reactor on 300 Grams Uranium Silicide Core

    International Nuclear Information System (INIS)

    Pande Made Udiyani; Lily Suparlina; Rokhmadi

    2007-01-01

    As starting of usage silicide U 250 g fuel element in the core of RSG-GAS and will be continued with usage of silicide U 300 g fuel element, hence done beforehand neutronic analyse and radiological safety of RSG-GAS. Calculation done by ORIGEN2.1 code to calculate source term, and also by PC-COSYMA code to calculate radiological safety of radioactive dispersion from RSG-GAS. Calculation of radioactive dispersion done at condition of reactor is postulated be happened an accident of LOCA causing one fuel element to melt. Neutronic analysis indicate that silicide U 250 g full core shall to be operated beforehand during 625 MWD before converted to silicide U 300 g core. During operation of transition core with mixture of silicide U 250 g and 300 g, all parameter fulfill criterion of safety Designed Balance core of silicide U 300 g will be reached at the time of fifth full core. Result of calculation indicate that through mixture core of silicide U 250 and 300 g proposed can form silicide U 300 g balance core of reactor RSG-GAS safely. Calculation of radiology safety by deterministic for silicide U 300 g balance core, and accident postulation which is equal to core of silicide U 250 g yield output in the form of radiation activity (radionuclide concentration in the air and deposition on the ground), radiation dose (collective and individual), radiation effect (short- and long-range), which accepted by society in each perceived sector. Result of calculation indicated that dose accepted by society is not pass permitted boundary for public society if happened accident. (author)

  10. Analysis of Ion-Exchange Resin Capability of the RSG-GAS Demineralized Water System (GCA01)

    International Nuclear Information System (INIS)

    Diyah Erlina Lestari; Setyo Budi Utomo; Harsono

    2012-01-01

    The Demineralized water system (GCA01) is a system which is function to process raw water to be demineralized water using ion exchange resin unit consisting of a column of cation exchange resins, anion exchange resin column and the column resin mix bed. After certain time the ion exchange resins to be saturated so that is needed regeneration. The RSG-GAS demineralized water system (GCA01) not operated continuously and indication of when does an ion exchange resin regeneration on The RSG-GAS demineralized water system (GCA01) is the water conductivity from anion exchange resin column output indicates ≥ 5μS/cm. Analysis of capability of the ion exchange resin demineralized water system (GCA01) line I has been performed. The analysis was done by comparing the time required in the system operating cycle of regeneration to the next regeneration during the period 2011 and 2012. From the results of the analysis showed the cycle regeneration time is varies. This shows that ion exchange resin capability of the RSG-GAS demineralized water system (GCA01) is varies depending on the raw water quality and success of the regeneration ion exchange resin. (author)

  11. Review of RSG-GAS secondary cooling pump performance

    International Nuclear Information System (INIS)

    Marsahala, Y.B.

    1999-01-01

    The control system of RSG-GAS secondary pump is the study for the operation existence of RSG-GAS secondary pump. The research is about characteristic of the secondary pump and its control system. The measuring of characteristic parameter of secondary cooling pump was being done while the pump running. The pump was loading with capacity 1950 m3/hr. with ambient temperature 28.5 oC. The fault effect of public grid (PLN) such as the fluctuation of both voltage and frequency likes voltage drops (dip). Supply block out that effect of the electric motor performances directly will be analyzed. How far those faults will effect the overall performance of secondary cooling system. Analyzing. Will be done according to the control system was installed. Has be done to find the direct effects of the motor performances against the motor rotation fluctuation which run from 1450 rpm to 1475 rpm. The using of start-delta starting method with delay time about 6 seconds, is enough or not to reduce the inrush starting current also analyzed in this paper. From the research can be obtained that in the steady state condition , the electric motor runs with both power and current are still under tolerances permitted. According to the analyzed data above, it will be consider that the control system of secondary pump would be modified or not. Therefore the analyzed data can show the characteristic curve of the secondary cooling system performance

  12. Study on the incore fuel management of RSG-GAS reactor

    International Nuclear Information System (INIS)

    Kuntjoro, S.; Sutiarso, K.; Praptoriadi, G.

    1995-01-01

    The RSG-GAS reactor was designed to work at nominal thermal power of 30 MW with average thermal neutron flux of 2.10 -14 cm -2 s -1 . Forty fuel assemblies and eight control assemblies are expected to form the typical working core (TWC) so that the pattern of the in-core fel management could be carried out properly. One of the requested safety conditions is that the reactor could still be shut down even if the control assemblies with highest negative reactivity were in failure work properly. It is not possible, with respect to the prerequested safety condition, to construct directly a typical working core. Utilizing the IAFUEL code program, a series of transition cores (the cores before reaching the TWC) were set up. The TWC is expected to be reached after eight transition cores. (author)

  13. Technical Of The Heat Exchanger System Of RSG-GAS Maintenance

    International Nuclear Information System (INIS)

    Murjati, Bambang; Tarigan, Alim; Saepudin C, Aep

    2001-01-01

    This first overhaul of RSG-GAS heat exchanger (HE 01) after 13 years operation had been done in May 29 until June 2, 2000. The result showed that the dimension of the some holes at the inlet side of HE 01 has shrunk but not at the outlet side. The shrank holes, then were cleaned using jet cleaner and aluminium pipe. The overhaul of HE 02 will be performed in the next period

  14. Evaluation Of Oxide And Silicide Mixed Fuels Of The RSG-GAS Core

    International Nuclear Information System (INIS)

    Tukiran; Sembiring, Tagor Malem; Suparlina, Lily

    2000-01-01

    Fuel exchange of the RSG-GAS reactor core from uranium oxide to uranium silicide in the same loading, density, and enrichment, that is 250 gr, 2.98 gr/cm 3 , and 19.75%, respectively, will be performed in-step wise. In every cycle of exchange with 5/1 mode, it is needed to evaluate the parameter of reactor core operation. The parameters of the reactor operation observed are criticality mass of fuels, reactivity balance, and fuel reactivity that give effect to the reactor operation. The evaluation was done at beginning of cycle of the first and second transition core with compared between experiment and calculation results. The experiments were performed at transition core I and II, BOC, and low power. At transition core I, there are 2 silicide fuels (RI-224 and R1-225) in the core and then, added five silicide fuels (R1-226, R1-252, R1-263, and R1-264) to the core, so that there are seven silicide fuels in the transition core II. The evaluation was done based on the experiment of criticality, control rod calibration, fuel reactivity of the RSG-GAS transition core. For inserting 2 silicide fuels in the transition core I dan 7 fuels in the transition core II, the operation of RSG-GAS core fulfilled the safety margin and the parameter of reactor operation change is not occur drastically in experiment and calculation results. So that, the reactor was operated during 36 days at 15 MW, 540 MWD at the first transition core. The general result showed that the parameter of reactor operation change is small so that the fuel exchange from uranium oxide to uranium silicide in the next step can be done

  15. Analysis of JKT01 Neutron Flux Detector Measurements In RSG-GAS Reactor Using LabVIEW

    Science.gov (United States)

    Rokhmadi; Nur Rachman, Agus; Sujarwono; Taryo, Taswanda; Sunaryo, Geni Rina

    2018-02-01

    The RSG-GAS Reactor, one of the Indonesia research reactors and located in Serpong, is owned by the National Nuclear Energy Agency (BATAN). The RSG-GAS reactor has operated since 1987 and some instrumentation and control systems are considered to be degraded and ageing. It is therefore, necessary to evaluate the safety of all instrumentation and controls and one of the component systems to be evaluated is the performance of JKT01 neutron flux detector. Neutron Flux Detector JKT01 basically detects neutron fluxes in the reactor core and converts it into electrical signals. The electrical signal is then forwarded to the amplifier (Amplifier) to become the input of the reactor protection system. One output of it is transferred to the Main Control Room (RKU) showing on the analog meter as an indicator used by the reactor operator. To simulate all of this matter, a program to simulate the output of the JKT01 Neutron Flux Detector using LabVIEW was developed. The simulated data is estimated using a lot of equations also formulated in LabVIEW. The calculation results are also displayed on the interface using LabVIEW available in the PC. By using this simulation program, it is successful to perform anomaly detection experiments on the JKT01 detector of RSG-GAS Reactor. The simulation results showed that the anomaly JKT01 neutron flux using electrical-current-base are respectively, 1.5×,1.7× and 2.0×.

  16. Analysis Influence of Mixing Gd2O3 in the Silicide Fuel Element to Core Excess Reactivity of RSG-GAS

    International Nuclear Information System (INIS)

    Susilo, Jati

    2004-01-01

    Gadolinium (Gd 2 O 3 ) is a burnable poison material mixed in the pin fuel element of the LWR core used to decrease core excess reactivity. In this research, analysis influence of mixing Gd 2 O 3 in the silicide fuel element to excess reactivity of the RSG-GAS core had been done. Equivalent cell of the equilibrium core developed by L.E.Strawbridge from Westing House Co. burn-up calculation has been done using SRAC-PIJ computer code achieve infinite multiplication factor (k x ). Value of Gd 2 O 3 concentration in the fuel element (pcm) showed by mass ratio of Gd 2 O 3 (gram) to that U 3 Si 2 (gram) times 10 5 , that is 0 pcm ∼ 100 pcm. From the calculation results analysis showed that Gd 2 O 3 concentration added should be considered. because a large number of Gd 2 O 3 will result in not achieving criticality at the Beginning Of Cycle. The maximum concentration of Gd 2 O 3 for RSG-GAS equilibrium fueled silicide 2.96 grU/cc is 80 pcm or 52.02 mgram/fuel plate. Maximum reduction of core excess reactivity due to mixing of Gd 2 O 3 in the RSG-GAS silicide fuels was around 1.502 %Δk/k, and hence not achieving the standard nominal excess reactivity for RSG-GAS core using high density of U 3 Si 2 -Al fuel. (author)

  17. MODEL SIMULATION OF GEOMETRY AND STRESS-STRAIN VARIATION OF BATAN FUEL PIN PROTOTYPE DURING IRRADIATION TEST IN RSG-GAS REACTOR

    Directory of Open Access Journals (Sweden)

    Suwardi Suwardi

    2015-03-01

    Full Text Available MODEL SIMULATION OF GEOMETRY AND STRESS-STRAIN VARIATION OF BATAN FUEL PIN PROTOTYPE DURING IRRADIATION TEST IN RSG-GAS REACTOR*. The first short fuel pin containing natural UO2 pellet in Zry4 cladding has been prepared at the CNFT (Center for Nuclear Fuel Technology then a ramp test will be performed. The present work is part of designing first irradiation experiments in the PRTF (Power Ramp Test Facility of RSG-GAS 30 MW reactor. The thermal mechanic of the pin during irradiation has simulated. The geometry variation of pellet and cladding is modeled by taking into account different phenomena such as thermal expansion, densification, swelling by fission product, thermal creep and radiation growth. The cladding variation is modeled by thermal expansion, thermal and irradiation creeps. The material properties are modeled by MATPRO and standard numerical parameter of TRANSURANUS code. Results of irradiation simulation with 9 kW/m LHR indicates that pellet-clad contacts onset from 0.090 mm initial gaps after 806 d, when pellet radius expansion attain 0.015 mm while inner cladding creep-down 0.075 mm. A newer computation data show that the maximum measured LHR of n-UO2 pin in the PRTF 12.4 kW/m. The next simulation will be done with a higher LHR, up to ~ 25 kW/m. MODEL SIMULASI VARIASI GEOMETRI DAN STRESS-STRAIN DARI PROTOTIP BAHAN BAKAR PIN BATAN SELAMA UJI IRADIASI DI REAKTOR RSG-GAS. Pusat Teknologi Bahan Bakar Nuklir (PTBBN telah menyiapkan tangkai (pin bahan bakar pendek perdana yang berisi pelet UO2 alam dalam kelongsong paduan zircaloy untuk dilakukan uji iradiasi daya naik. Penelitian ini merupakan bagian dari perancangan percobaan iradiasi pertama di PRTF (Power Ramp Test Fasility yang terpasang di reaktor serbaguna RSG-GAS berdaya 30 MW. Telah dilakukan pemodelan dan simulasi kinerja termal mekanikal pin selama iradiasi. Variasi geometri pelet dan kelongsong selama pengujian dimodelkan dengan memperhatikan fenomena ekspansi termal

  18. Reliability analysis of the multi purposes reactor G.A. siwabessy (MPR.GAS) using data base

    International Nuclear Information System (INIS)

    Handoyo, Demon; Tjahjani, D.T. Sony; M, Dwijo; K, Slamet

    1999-01-01

    The purpose of development of the MPR GAS component and system data base is to know characteristic of reliability of component and system of the MPR GAS. The analysis have been done base on component operating experiences and the data collection from the operation logbook. The operation data provide values such as: the operation time of component, number of failure, number of demand and number of the component of MPR GAS. Number of failure rate from 1990 until 1998/99 of pumps in fuel Storage Pool Purification System (FAK-AP) = 0.65∼2.1 10-4/hr, Primary Cooling System (JE01-AP) = 0.54∼6.9 10-4/hr, Primary Pool Purification System (KBE01- AP) = 0.23∼0.,26 10-4/hr, Warm layer System (KBE02-AP)= 0.88∼1.9 10-4/hr,Cooling tower (PA/D-AH)=0.88∼3.8 10-4/hr, Secondary Cooling System 9PA-AP)=0.94∼3.5 10-4/hr and Genset (BRV)= 0.2∼2.4 10-2 /demand. The data of failure probability of pump from IAEA-TECDOC-478 is 1 10-6 ∼ 2.9 10-5/hr, and of failure probability of genset from IAEA-TECDOC-478 is 2.9 10-3 ∼ 3 10-2/demand

  19. Evaluation of RSG-GAS Core Management Based on Burnup Calculation

    International Nuclear Information System (INIS)

    Lily Suparlina; Jati Susilo

    2009-01-01

    Evaluation of RSG-GAS Core Management Based on Burnup Calculation. Presently, U 3 Si 2 -Al dispersion fuel is used in RSG-GAS core and had passed the 60 th core. At the beginning of each cycle the 5/1 fuel reshuffling pattern is used. Since 52 nd core, operators did not use the core fuel management computer code provided by vendor for this activity. They use the manually calculation using excel software as the solving. To know the accuracy of the calculation, core calculation was carried out using two kinds of 2 dimension diffusion codes Batan-2DIFF and SRAC. The beginning of cycle burn-up fraction data were calculated start from 51 st to 60 th using Batan-EQUIL and SRAC COREBN. The analysis results showed that there is a disparity in reactivity values of the two calculation method. The 60 th core critical position resulted from Batan-2DIFF calculation provide the reduction of positive reactivity 1.84 % Δk/k, while the manually calculation results give the increase of positive reactivity 2.19 % Δk/k. The minimum shutdown margin for stuck rod condition for manual and Batan-3DIFF calculation are -3.35 % Δk/k dan -1.13 % Δk/k respectively, it means that both values met the safety criteria, i.e <-0.5 % Δk/k. Excel program can be used for burn-up calculation, but it is needed to provide core management code to reach higher accuracy. (author)

  20. Nodalization Preparation for the Transient Simulation of Cooling System for One Line Mode of RSG-GAS

    International Nuclear Information System (INIS)

    Sukmanto Dibyo; Susyadi; Tagor MS; Darwis Isnaeni

    2004-01-01

    Cooling system is important component in RSG-GAS. To carry out the transient simulation of one line-cooling mode, the model of RSG-GAS has been prepared. To illustrate the transient condition, the RELAP5.MOD3 computer code the existing input files were used. This Input consist of kinetic, thermal, hydraulic and geometries data. Modification and decrement of number of nodalization has been done to simplification as well as running time. The reasonable result of model is arranged to determine the initial condition of input data therefore steady state condition have agreement to the analysis result of one line cooling mode of RSG-GAS. Parameter investigated are transient temperatures of cooling system after decreasing of secondary cooling system occur as function of time. These parameters can be requested using input of Minor Edit Request Simulation is conducted at the reactor power of 15 MW steady-state for one-line cooling mode in which the primary and secondary cooling of 430 kg/sec and 550 kg/sec respectively. Decreasing of secondary cooling flow is caused by pump trip. As a consequence, the control rod drop due to reactor protection system. The negative reactivity of control rod causes decreasing of reactor power. Change of pattern for the primary and secondary cooling system can be known. After that simulation depicts that increasing of temperatures occur at the certain moment since initiation temperature conditions, due to reactor shut down, curve inclined move going down. (author)

  1. Analysis of gamma dose for 4,8 gU/cm3 density silicide core at the RSG-GAS reactor using MCNP code

    International Nuclear Information System (INIS)

    Ardani

    2011-01-01

    Radiation safety analysis should be done following of substitution of fuel density of 2.96 gU/cc to density of 4,8 gU/cc silicide fuels for the RSG-GAS reactor. MCNP-5 code has been used to perform gamma dose calculation of the RSG-GAS reactor. Gamma radiation source at reactor consists of capture gamma rays, prompt fission gamma rays, and gamma rays of decay of fission and activation products. The strength of the prompt fission gamma rays is obtained by gamma releases of fission process of U-235 and reactor power of 30 MWt., during 46,6 days operation. Radiation dose is calculated at the experimental hall by detection point at the surface of outer of biological shielding and the operation hall by detection point at the top of the pool. The calculation is conducted at reactor on the normal operation and on the worst postulated accident causing the water level at the pool decreases. Calculation result shows that the biggest source strength of gamma rays come from the decay process. The highest calculated dose at the experiment hall is 4,07x10 -3 μSv/h, far from the maximum external dose permitted 25 μSv/h. The highest calculated dose at the operation hall is 19.98 μSv/h. Even though the calculated dose is still acceptable but this is close to the maximum permitted dose for worker. It concluded that loading of 4,8 gU/cc silicide fuel for the RSG-GAS still safe. (author)

  2. Kinetics parameter measurements on RSG-GAS, a low-enriched fuel reactor

    International Nuclear Information System (INIS)

    Jujuratisbela, U; Arbie, B; Pinem, S.; Tukiran; Suparlina, L.; Singh, O.P.

    1995-01-01

    Kinetics parameter measurements, such as reactivity worths of control rods and fuel elements, beam tube void reactivity, power reactivity coefficient and xenon poisoning reactivity have been performed on different cores of Reaktor Serba Guna G.A. Siwabessy (RSG-GAS). In parallel, a programme was also initiated to measure the other kinetics parameters like effective delayed neutron life time, prompt neutron decay constant, validation of period reactivity relationship and zero power frequency response function. The paper provides the results of these measurements. (author)

  3. Application of noise analysis on the operation of the RSG-GAS reactor

    International Nuclear Information System (INIS)

    Surian P, Tukiran S

    1999-01-01

    The RSG-GAS reactor has been operating for radioisotope production and experiments so that it is necessary to perform analysis of the reactor operation. analysis was done based on reactor noise experiment. Neutron noise at low and high power of the RSG-GAS has been analyzed using time and frequency domain with aim to determine the safety of reactor operation. The safety of reactor operation based on two parameters as, prompt neutron decay constant and decay ratio. The parameters are useful for reactor operation, so it is necessary to determine accurately. For determining prompt neutron decay constant, neutron density in the core of reactor which operated at 10 k W, was collected by using Fission Chamber detectors (FC). Based on power spectral density (PSD) was achieved break frequency about 23 Hz, so that the prompt neutron decay constant is about 151 sec -1 . While at at high power 20 MW, neutron density was collected by using Compensated Ionization Chamber (CIC) detector. The result at high power showed that there is reactivity effect in the core because of fluctuation in temperature and density of the coolant, and the decay ratio of 0.20, showed that the reactor is still operation in stable

  4. Analysis Of Temperature Effects On Reactivity Of The Rsg-Gas Core Using Silicide Fuels

    International Nuclear Information System (INIS)

    Surbakti, Tukiran; Pinem, Surian

    2001-01-01

    RSG-GAS has been operating using new silicide fuels so that it is necessary to estimate and to measure the effect of temperature on reactivity of the core. The parameters to be determined due to temperature effect are reactivity coefficient of moderator temperature, temperature coefficient of fuel element and power reactivity coefficient. By doing a couple compensation method, determination of reactivity coefficient as well as the reactivity coefficient of moderator temperature can be obtained. Furthermore, coefficient of the reactivity was successfully estimated using the combination of WIMS-D4 and Batan-2DIFF. The cell calculation was done by using WIMS-D4 code to get macroscopic cross section and Batan-2DIFF code is used for core calculation. The calculation and experimental results of reactivity coefficient do not show any deviation from RSG-GAS safety margin. The results are -2,84 sen/ o C, -1,29 sen/MW and -0,64 sen/ o C for reactivity coefficients of temperature, power, fuel element and moderator temperature, respectively. All of 3 parameters are absolutely met with safety criteria

  5. Thermal hydraulic And RSG-Gas Core Reactivity Characteristics Due To Cold Water Insertion Accident

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Suparlina, Lily; Tukiran

    2000-01-01

    Under normal operating condition,the primary coolant is circulated by 2 out of the 3 primary coolant pumps. Unnecessary operation of the reserve pump would result in a temperatur decrease of the primary coolant by less than 5 o C. the corresponding increase of reactivity amounts to Δρ ≤0,1 %. The analysis was done using silicide core configuration data with 3.55 gU /cm 3 fuel loading. The calculation model was done with and without automatic control rod. The calculation results for the worst case condition, shows that reactor reached the maximum power 28.52 MW at 81.1 seconds, after the accident occurred. The maximal fuel element, cladding and outlet coolant temperatures are 148.3 o C,142.1 o C, and 75.7 o C, respectively. Safety margins for DNBR and flow instability reached 1.25 and 4.20, respectively. Comparing to the RSG-GAS safety margin at transient condition reguirement >1.48, RSG-GAS has enough safety margin if the power trip executed at 114% of 25 MW

  6. The influence Of On Power Target Loading At RSG-GAS Reactor

    International Nuclear Information System (INIS)

    Kusno; Pardi

    2001-01-01

    One of utilization purposes of the RSG-GAS reactor is to produce radioisotope. The target insertion or withdrawal on the irradiation position D-6 and E-7 in the core can be done manually, during reactor operation or shut down condition. The problem arises when the loading is under operation mode, because of flow and reactivity change the reactivity. The behavior of operation parameter changes due to target handling will be investigated in this paper. The behavior will be applied as a guidance of the operating group in handling the irradiation target

  7. Analysis of Beryllium Having Irradiated at the RSG-GAS Core using ORIGEN2 Code

    International Nuclear Information System (INIS)

    Jaja Sukmana; Jonnie AK; S-Suwarto; Irwan

    2012-01-01

    Analysis of activation products generated by irradiated beryllium at the RSG-GAS core has been done using ORIGEN2 code. By assuming that irradiation is 176 days, neutron flux average of 2.30e+14 n/cm 2 s, radioisotopes rose from activated Be are tritium, lithium, beryllium, carbon, magnesium, aluminum, silicon, argon, calcium, scandium, vanadium, chromium, manganese, iron, cobalt, nickel, copper, zinc, silver, and lead. The highest activity after 100 days of irradiation demonstrated by Be-10 (7.99 E-03 Curie), H-3 (2.97 E-03 Curie), Cr-51, Fe-55 and Co-60. Radioactivity generated getting smaller when irradiation time are long. From this analysis it can be conclude that radioactivity was caused by impurities present in Be such as Mn-54, Fe-59, Zn-65, and Li-6. (author)

  8. Evaluation of components and systems of RSG-GAS and developing of maintenance evaluation software

    International Nuclear Information System (INIS)

    Pane, Jupiter-Sitorus; Kadarusmanto

    2003-01-01

    In order to enhance the evaluation of components and systems, inventarization of failure and repair data has been performed. The evaluation was done by calculating distribution function of failure, failure rate, MTTF, MTTR, and unavailability. The evaluation was comprehend in a code program of SYSCOM-RSG-GAS, that are able to performed statistical analysis, reliability parameters, and Fault Tree Analysis. This paper will describe some results of the program

  9. Neutronic design of the RSG-GAS silicide core

    Energy Technology Data Exchange (ETDEWEB)

    Sembiring, T.M.; Kuntoro, I.; Hastowo, H. [Center for Development of Research Reactor Technology National Nuclear Energy Agency BATAN, PUSPIPTEK Serpong Tangerang, 15310 (Indonesia)

    2002-07-01

    The objective of core conversion program of the RSG-GAS multipurpose reactor is to convert the fuel from oxide, U{sub 3}O{sub 8}-Al to silicide, U{sub 3}Si{sub 2}-Al. The aim of the program is to gain longer operation cycle by having, which is technically possible for silicide fuel, a higher density. Upon constraints of the existing reactor system and utilization, an optimal fuel density in amount of 3.55 g U/cc was found. This paper describes the neutronic parameter design of the silicide equilibrium core and the design of its transition cores as well. From reactivity control point of view, a modification of control rod system is also discussed. All calculations are carried out by means of diffusion codes, Batan-EQUIL-2D, Batan-2DIFF and -3DIFF. The silicide core shows that longer operation cycle of 32 full power days can be achieved without decreasing the safety criteria and utilization capabilities. (author)

  10. ANALISIS PENGARUH DENSITAS BAHAN BAKAR SILISIDA TERHADAP PARAMETER KINETIK TERAS REAKTOR RSG-GAS

    Directory of Open Access Journals (Sweden)

    Tukiran s

    2016-11-01

    Full Text Available Saat ini RSG-GAS menggunakan elemen bakar silisida 2,96 g U/cc. Untuk meningkatkan waktu operasi reaktor maka akan direncanakan untuk mengganti elemen bakar silisida dengan kerapatan yang lebih tinggi. Keuntungan reaktor dengan bahan bakar kerapatan tinggi adalah dapat lebih efektif dan efisien. Maka perlu dilakukan perhitungan parameter kinetik teras silisida kerapatan tinggi mengingat pengaruhnya sangat penting untuk keselamatan operasi reaktor. Parameter kinetik yang dihitung yaitu fraksi neutron kasip efektif, konstanta peluruhan neutron kasip, umur neutron serempak yang merupakan faktor utama dalam kontrol dan keselamatan. Bahan bakar silisida tipe pelat dengan densitas 2,96 - 4,8 gU/cm3 digunakan pada teras RSG-GAS untuk menganalisis perhitungan parameter kinetik. Perhitungan sel dilakukan dengan paket program WIMSD-5B dan paket program Batan-2DIFF digunakan untuk perhitungan teras. Hasil perhitungan menunjukkan bahwa harga fraksi neutron kasip turun dengan naiknya densitas bahan bakar. Turunnya nilai parameter kinetik ini tidak mengganggu pergantian bahan bakar ke densitas yang lebih tinggi. Turunnya nilai parameter kinetik rata-rata dari densitas 2,96 gU/cm3 ke 3,55 gU/cm3 adalah 1,3 % sedangkan dari densitas 2,96 gU/cm3 ke 4,8 gU/cm3 adalah 2,2 % . Sehingga jika dilakukan pergantian bahan bakar maka ditinjau dari segi neutronik dan parameter kinetiknya tidak akan mengalami perubahan dalam pola operasi reaktor atau manajemen bahan bakar dan tidak akan berpengaruh terhadap keselamatan operasi reaktor.

  11. Relap5 simulation for severe accident analysis of RSG-GAS Reactor

    International Nuclear Information System (INIS)

    Andi Sofrany Ekariansyah; Endiah P-Hastuti; Sudarmono

    2018-01-01

    The research reactor in the world is to be known safer than power reactor due to its simpler design related to the core and operational characteristics. Nevertheless, potential hazards of research reactor to the public and the environment can not be ignored due to several special features. Therefore the level of safety must be clearly demonstrated in the safety analysis report (SAR) using safety analysis, which is performed with various approaches and methods supported by computational tools. The purpose of this research is to simulate several accidents in the Indonesia RSG-GAS reactor, which may lead to the fuel damage, to complement the severe accident analysis results that already described in the SAR. The simulation were performed using the thermal hydraulic code of RELAP5/SCDAP/Mod3.4 which has the capability to model the plate-type of RSG-GAS fuel elements. Three events were simulated, which are loss of primary and secondary flow without reactor trip, blockage of core subchannels without reactor trip during full power, and loss of primary and secondary flow followed by reactor trip and blockage of core subchannel. The first event will harm the fuel plate cladding as showed by its melting temperature of 590 °C. The blockage of one or more subchannels in the one fuel element results in different consequences to the fuel plates, in which at least two blocked subchannels will damage one fuel plate, even more the blockage of one fuel element. The combination of loss of primary and secondary flow followed by reactor trip and blockage of one fuel element has provided an increase of fuel plate temperature below its melting point meaning that the established natural circulation and the relative low reactor power is sufficient to cool the fuel element. (author)

  12. Preliminary study or RSG-GAS reactor fuel element integrity

    International Nuclear Information System (INIS)

    Soejoedi, A.; Tarigan, A.; Sujalmo; Prayoga, S.; Suhadi

    1996-01-01

    After 8 years of operation, RSG-GAS was able to reach 15 cycles of reactor operation with 116 irradiated fuels, whereas 49 fuels were produced by NUKEM; and the other 67 were produced by PEBN-BATAN. At the 15 T h cycles, it have been used 40 standard fuels and 8 control fuels (Forty standard fuels and eight control fuels have been used in the 15 t h core cycles). Several activities have been performed in the reactor, to investigate the fuel integrity, among of them are: .fuel visual test with under water camera, which the results were recorder in the video cassette, primary water quality test during, reactor operation, fuel failure detector system examination and compared the PIE results in the Radiometallurgy Installation (RMI). The results showed that the fuel integrity, before and after irradiation, have still good performance and the fission products have not been released yet

  13. Preliminary Analysis of High-Flux RSG-GAS to Transmute Am-241 of PWR’s Spent Fuel in Asian Region

    Science.gov (United States)

    Budi Setiawan, M.; Kuntjoro, S.

    2018-02-01

    A preliminary study of minor actinides (MA) transmutation in the high flux profile RSG-GAS research reactor was performed, aiming at an optimal transmutation loading for present nuclear energy development. The MA selected in the analysis includes Am-241 discharged from pressurized water reactors (PWRs) in Asian region. Until recently, studies have been undertaken in various methods to reduce radiotoxicity from actinides in high-level waste. From the cell calculation using computer code SRAC2006, it is obtained that the target Am-241 which has a cross section of the thermal energy absorption in the region (group 8) is relatively large; it will be easily burned in the RSG-GAS reactor. Minor actinides of Am-241 which can be inserted in the fuel (B/T fuel) is 2.5 kg which is equivalent to Am-241 resulted from the partition of spent fuel from 2 units power reactors PWR with power 1000MW(th) operated for one year.

  14. Preliminary study of radionuclide corrosion products in primary cooling water at RSG-GAS

    International Nuclear Information System (INIS)

    Lestari, D.E.; Pudjojanto, M.S.; Subiharto; Budi, S.

    1998-01-01

    Analysis of radionuclides emitting gamma rays at the primary cooling water at RSG-GAS has been carried out. The water coolant samples was performed using a low level background gamma spectrometer unit, including of high resolution of gamma detector HP-Ge Tennelec and Multichannel Analyzer (MCA) ADCAM 100 ORTEC. The result indicated Na-24 and Mn-56 radionuclides that may be as corrosion product and should studied deeply in the future. The expected activity concentration radionuclide for Mn-56 is lower than those written in the Safety Analysis Report (SAR), while for Na-24 is in agreement

  15. Characteristic of The RSG-Gas Oxide Fuel Element Temperature Under Forced Convection And Natural Convection Mode

    International Nuclear Information System (INIS)

    Sudarmono

    2000-01-01

    One of the methods used for fuel element plate temperature measurement in RSG-Gas is a direct measurement. Evaluation on the measurement results were done by using HEATHYDE and NATCON code, which was then compared to the safety margin criteria. Results of thermalhydraulic measurement on transitional core both under forced and natural convection were compared with the results of calculations using the two codes. Measurement result for maximum fuel element plate temperature at typical working core of 30 MW, was 121 o C. The deviation between calculation and measurement result was under 9.75 %. Under normal operation, safety margin on DNB and OFI are 3.56 and 2.60, respectively. Natcon calculation result showed that the typical working core under the natural circulation mode, an onset of nucleate boiling (ONB)occurred at a core power level of 826 kW (2.8% of the nominal power)

  16. Analysis of RSG-GAS Control Rod Worth Due to Perturbation Reactivity

    International Nuclear Information System (INIS)

    Taswanda Taryo

    2004-01-01

    The control rod interaction effect of RSG-GAS typical working core was studied using a method based on the exact perturbation theory with three simplifying assumptions which require only N+1 criticality calculations. The interaction effect between two interacting rods reached up to 19 % while the interaction effect of multiple interacting rods reached up to 32 % for all (8) control rods involved. The accuracy of the adopted method were extensively investigated to determine the error sources and the magnitude of the error. Through comparison of the present results with ones of the simple summation method, it was obvious that the adopted method was superior in that a significant improvement on the accuracy of the calculated reactivity worth can be achieved with a small number of criticality calculations. (author)

  17. A procedure for searching the equilibrium core of a research reactor

    International Nuclear Information System (INIS)

    Bakri Arbie; Liem Peng Hong; Prayoto

    1996-01-01

    A procedure for searching the equilibrium core of a research reactor has been proposed. The searching procedure is based on the relaxation method and has been implemented in Batan-EQUIL-2D in-core fuel management code. The few-group neutron diffusion theory in 2-D, X-Y, and R-Z reactor geometries are adopted as the framework of the code. The successful applicability of the procedure for obtaining the new RSG-GAS (MPR-30) silicide equilibrium core was shown. (author)

  18. Analysis of impurity effect on Silicide fuels of the RSG-GAS core

    International Nuclear Information System (INIS)

    Tukiran-Surbakti

    2003-01-01

    Simulation of impurity effect on silicide fuel of the RSG-GAS core has been done. The aim of this research is to know impurity effect of the U-234 and U-236 isotopes in the silicide fuels on the core criticality. The silicide fuels of 250 g U loading and 19.75 of enrichment is used in this simulation. Cross section constant of fuels and non-structure material of core are generated by WIMSD/4 computer code, meanwhile impurity concentration was arranged from 0.01% to 2%. From the result of analysis can be concluded that the isotopes impurity in the fuels could make trouble in the core and the core can not be operated at critical after a half of its cycle length (350 MW D)

  19. H2 gas pressure calculation of FPM capsule failure at RSG-GAS reactor core

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Sunaryo, Geni Rina

    2002-01-01

    RSG-GAS has been irradiated FPM capsule for 236 times, one of those i.e. capsule number 228 has failure. The one of root cause of failure possibility is radiolysis reaction can be occurred in FPM capsule when it is filled with water during irradiation in the reactor core. The safety analysis of the radiolysis reaction in the capsule has been done. The oc cumulative hydrogen gas production can cause high pressure in the capsule then a mechanical damage occurred. The analysis was done at 10 MW of reactor power which equivalent with neutron flux of 0,6929 x 10 1 4 n/cm 2 sec and γ dose rate of 0,63x10 9 rad/hour. The assumption is the capsule is filled with water at maximum volume, i.e. 176.67 ml. The results of calculation showed that radiolysis reaction with γ and neutron produce hydrogen gas for nominal flow rate each are 494 atm and 19683 atm for γ and neutron radiolysis, respectively. H 2 gas pressure for 5% flow rate each are 723 atm. and 25772 atm., for γ and neutron radiolysis, respectively. The changing of the operation condition due to radiolysis together with one way valve' phenomena, can be produce hydrogen gas from water during irradiation in the reactor core and can be the one of root cause of capsule failure. This analysis recommended the FPM capsule preparation must be guaranteed no water or/and there is no possibility of water immersion in the capsule during irradiation in the core by more accurate leak test

  20. LOFA and RIA analysis of the Indonesian Multipurpose research reactor RSG-GAS 1)

    International Nuclear Information System (INIS)

    Endiah Puji Hastuti; Hudi Hastowo; Iman Kuntoro

    1999-01-01

    Investigation on accident of the Indonesian Multipurpose research reactor RSG-GAS has been performed by computer simulation technique. Two groups of transients were considered, namely transient due to loss of primary cooling system (LOFA) and power excursion due to reactivity insertion (RIA). In such a transient condition, the Common Mode Failure (CMF) is considered and it will induce a situation so called unprotected transient or Anticipated Transient Without Scram (ATWS). RELAP5, PARET-ANL and EUREKA-2RR computer packages have been applied for these analyses. Simulations result done using these computer packages showed that in the occurrence of LOFA and RIA, failure on fuel elements is limited to the region with the highest power factor. (author)

  1. The analysis of coolant-velocity distribution in plat-typed fuel element using CFD method for RSG-GAS research reactor

    International Nuclear Information System (INIS)

    Muhammad Subekti; Darwis Isnaini; Endiah Puji Hastuti

    2013-01-01

    The measurement experiment for coolant-velocity distribution in the subchannel of fuel element of RSG-GAS research reactor is difficult to be carried out due to too narrow channel and subchannel placed inside the fuel element. Hence, the calculation is required to predict the coolant-velocity distribution inside subchannel to confirm that the handle presence does not ruin the velocity distribution into every subchannel. This calculation utilizes CFD method, which respect to 3-dimension interior. Moreover, the calculation of coolant-velocity distribution inside subchannel was not ever carried out. The research object is to investigate the distribution of coolant-velocity in plat-typed fuel element using 3-dimension CFD method for RSG-GAS research reactor. This research is required as a part of the development of thermalhydraulic design of fuel element for innovative research reactor as well. The modeling uses ½ model in Gambit software and calculation uses turbulence equation in FLUENT 6.3 software. Calculation result of 3D coolant-velocity in subchannel using CFD method is lower about 4.06 % than 1D calculation result due to 1D calculation obeys handle availability. (author)

  2. Evaluation of In-Core Fuel Management for the Transition Cores of RSG-GAS Reactor to Full-Silicide Core

    International Nuclear Information System (INIS)

    S, Tukiran; MS, Tagor; P, Surian

    2003-01-01

    The core conversion of RSG-GAS reactor from oxide to silicide core with meat density of 2.96 gU/cc has been done. The core-of RSG-GAS reactor has been operated full core of silicide fuels which is started with the mixed core of oxide-silicide start from core 36. Based on previous work, the calculated core parameter for the cores were obtained and it is needed 9 transition cores (core 36 - 44) to achieve a full-silicide core (core 45). The objective of this work is to acquire the effect of the increment of the number of silicide fuel on the core parameters. Conversion core was achieved by transition cores mixed oxide-silicide fuels. Each transition core is calculated and measured core parameter such as, excess reactivity and shutdown margin. Calculation done by Batan-EQUIL-2D code and measurement of the core parameters was carried out using the method of compensation of couple control rods. The results of calculation and experiment shows that the excess reactivity trends lower with the increment of the number of silicide fuel in the core. However, the shutdown margin is not change with the increment of the number of silicide fuel. Therefore, the transition cores can be operated safely to a full-silicide core

  3. Design and manufacturing concrete cells for shielding and storing radioactive semi liquid waste (resin) from MPR-GAS

    International Nuclear Information System (INIS)

    Pudjijanto-MS; Bahdir-Johan

    2003-01-01

    Semi liquid or quasi solid waste on Multipurpose Reactor G.A. Siwabessy (MPR-GAS) produced from operating resin rinsing systems and resin disposal systems during changes insert trap resin. Volume of the disposal resin waste in the filter mixed-bed per operation rinsing period are approx. 1.00 m 3 (in the Primary Cooling Water Treatment System) with activity ∼ 18.6 Ci/m 3 (0.688 TBq/m 3 ), 0.50 m 3 (in the Radioisotope Storage Pool Water Treatment System) with activity approx ∼ 0.162 Ci/m 3 (5.99 x 10 3 MBq/m 3 ) and 0.50 m 3 (in the Interim Spent Fuel Storage Pool Water Treatment System) with activity ∼ 0.162 Ci/m 3 (5.99 x 10 3 MBq/m 3 ) respectively. On the discharging and unloading, the gross radioactivity concentration of the resin waste loaded in the disposal resin waste tank are approx. 10 Ci/m 3 (0.37 TBq/m 3 ). After 6 months delayed, this activity is still 0.32 Ci/m 3 (11.84 GBq/m 3 ). Based on this data, some concrete cells to storage resin waste as semi liquid or quasi solid waste produced continuously by MPR-GAS installation has been designed and manufactured eternally

  4. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  5. Performance Evaluation of the RSG-GAS Micronomad MCA

    International Nuclear Information System (INIS)

    Badriyana, B.; Pujijanto, M.S.

    2000-01-01

    The MicroNOMAD-MCA is a gamma spectrometer for radiation exposure measurement using matrix respond method. The equipment used NAI detector to produced pulse spectrum and then covert to quantities of dosimeter by a computer program. Performance evaluation of the MCA-MicroNOMAD has been done to evaluate the reliability and accuracy of the measurement result. The evaluation was done by comparison test with standard survey meter. Measurement of gamma radiation was performed in the experimental Hall, Operation Hall of the RSG-GAS and outside of reactor building with 15 MW reactor power. The gamma radiation exposure measurement result in the Experimental Hall using the MicroNOMAD MCA and Ion Chamber survey meter are 92,4 x 10 exp 6 rad/hour and (62 ∼ 88) x 10 exp 6 rad/hour, respectively. The gamma radiation exposure in the Operation Hall using the MicroNOMAD MCA and Ion Chamber are 165,4 x 10 exp 6 rad/hour and (167 ∼ 194) x 10 exp 6 rad/hour, respectively. By means of this result it can concluded that the reading error of the MicroNOMAD MCA with standard survey meter is small enough. Beside the point the MicroNOMAD MCA has a good performance for gamma radiation measurement in the energy range of 0,2 - 9 MeV

  6. Attempt to produce silicide fuel elements in Indonesia

    International Nuclear Information System (INIS)

    Soentono, S.; Suripto, A.

    1991-01-01

    After the successful experiment to produce U 3 Si 2 powder and U 3 Si 2 -Al fuel plates using depleted U and Si of semiconductor quality, silicide fuel was synthesized using x -Al available at the Fuel Element Production Installation (FEPI) at Serpong, Indonesia. Two full-size U 3 Si 2 -Al fuel elements, having similar specifications to the ones of U 3 O 8 -Al for the RSG-GAS (formerly known as MPR-30), have been produced at the FEPI. All quality controls required have been imposed to the feeds, intermediate, as well as final products throughout the production processes of the two fuel elements. The current results show that these fuel elements are qualified from fabrication point of view, therefore it is expected that they will be permitted to be tested in the RSG-GAS, sometime by the end of 1989, for normal (∝50%) and above normal burn-up. (orig.)

  7. Reactors Dynamic analysis Due to Reactivity of The RSG-Gas at One Line Cooling Mode

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji

    2003-01-01

    In the frame of minimizing the operation-cost, operation mode using one line cooling system is being evaluated. Maximum reactor power has been determined and steady state and LOFA transient analysis have also been done. To complete those analyses, the reactivity analysis was done by means of a core dynamic and thermal hydraulic code, PARET-ANL. Accident simulation was done. by a ramp reactivity accident due to control rod withdrawal. Reactivity analysis was carried out at two power range i.e. low and high power level, by imposing one line mode reactor protection limits. The results show that technically, the RSG-Gas can be operated safely using one line mode

  8. The Analysis of RSG-GAS Spent Fuel Elements Utilization as a Gamma Irradiator

    International Nuclear Information System (INIS)

    Pudjijanto MS; Setiyanto

    2004-01-01

    A gamma irradiator using RSG-GAS spent fuels was analyzed. The cylindrical geometry of the irradiator was designed using spent fuels placed in the cylindrical periphery. The analysis especially was focused to evaluate the feasibilities of the irradiator for foods and non-foods which need not too high dose rates. While the spent fuels activities were calculated by ORIGEN2 code, the dose rates at the irradiation positions were determined by linear attenuation model with transport coefficient. The evaluated results showed that the cylindrical geometry of the irradiator with diameter around 1-1.5 m gave the effective dose rate for irradiation needs the dose rate about 2 kGy/hr. Regarding this work, it can be concluded that one can use the unutilized spent fuels effectively as a gamma irradiator for certain applications. (author)

  9. Primary study for boron neutron capture therapy uses the RSG-GAS beam tube facility

    International Nuclear Information System (INIS)

    Suroso

    2000-01-01

    The minimum epithermal neutron flux as one of the prerequisite of Boron Neutron Capture Therapy (BNCT) is 1.0 x 10 9 n/(cm 2 s) RSG-GAS have 6 beam tube facilities for neutron source, which is one of the beam tube S-2 has a possibility to utilization for BNCT facility. The totally flux neutron measurement in the front of S-2 beam tube is 1.8 x 10 7 n/(cm 2 s). The neutron flux measurement was less than for BNCT minimum prerequisite. Concerning to the flux neutron production in the reactor, which is reach to 2.5 x 10 14 n/(cm 2 s), there for the S-2 beam tube could be used beside collimator modification

  10. Development of Coincidence Method for Determination Thermal Neutron Flux on RSG-GAS

    International Nuclear Information System (INIS)

    Bakhri, Syaiful; Hamzah, Amir

    2004-01-01

    The research to develop detection radiation system using coincidence method has been done to determine thermal neutron flux in RS1 and RS2 irradiation facilities RSG-GAS. At this research has arranged beta-gamma coincidence equipment system and parameter of measurement according to Au-198 beta-gamma spectrum. Gold foils that have irradiated for period of time, counted, and the activities of radiation is analyzed to get neutron flux. Result of research indicate that systems measurement of absolute activity with gamma beta coincidence method functioning well and can be applied at activity measurement of gold foil for irradiation facility characterization. The results show that thermal neutron flux in RS1 and RS2, respectively is 2.007E+12 n/cm 2 s and 2.147E+12 n/cm 2 s. To examine the system performance, the result was compared to measure activity using high resolution of Hp Ge detector and achieved discrepancy is about 1.26% and 6.70%. (author)

  11. Performance Evaluation of the New Fork-Absorbers of RSG-GAS Control Rod

    International Nuclear Information System (INIS)

    Slamet Wiranto; Purwadi; Arif Hidayat; Agus Sanjaya

    2012-01-01

    During the operation of RSG-GAS reactor, it has been replaced 8 fork-absorber by the new absorber from PT. Batan Teknologi. After almost 5 years under utilization it is important to be evaluated to determine the physical condition and its performance, which is still in good condition and functioning according to the requirements of its operations. The evaluation has been carried out by studying and analyzing the data of the fork-absorber utilization in the the reactor core. The fork absorber data consist of visual inspection, control rod drop time measurement and control rod reactivity and safety margin measurement for each operation cycle. Through the observation up to date with the operating cycle of 79, could be concluded that the fork-absorber condition is still good, and has ability, to support the operation until ± 660 MWD/cycle, which is characterized by obtaining the value of ρ-excess is sufficient for operation, with a large safety margin. (author)

  12. Modelling the radiolysis of RSG-GAS primary cooling water

    Science.gov (United States)

    Butarbutar, S. L.; Kusumastuti, R.; Subekti, M.; Sunaryo, G. R.

    2018-02-01

    Water chemistry control for light water coolant reactor required a reliable understanding of radiolysis effect in mitigating corrosion and degradation of reactor structure material. It is known that oxidator products can promote the corrosion, cracking and hydrogen pickup both in the core and in the associated piping components of the reactor. The objective of this work is to provide the radiolysis model of RSG GAS cooling water and further more to predict the oxidator concentration which can lead to corrosion of reactor material. Direct observations or measurements of the chemistry in and around the high-flux core region of a nuclear reactor are difficult due to the extreme conditions of high temperature, pressure, and mixed radiation fields. For this reason, chemical models and computer simulations of the radiolysis of water under these conditions are an important route of investigation. FACSIMILE were used to calculate the concentration of O2 formed at relatively long-time by the pure water γ and neutron irradiation (pH=7) at temperature between 25 and 50 °C. This simulation method is based on a complex chemical reaction kinetic. In this present work, 300 MeV-proton were used to mimic γ-rays radiolysis and 2 MeV fast neutrons. Concentration of O2 were calculated at 10-6 - 106 s time scale.

  13. Installation design of pump motor control systems for supplied of the RSG-GAS secondary raw water cooling system

    International Nuclear Information System (INIS)

    Kiswanto; Teguh Sulistyo; M-Taufik

    2013-01-01

    It has designed already of an installation of the pump motor control system for supplied of raw water to fulfil the RSG-GAS secondary cooling system. The installation design of this plant is used to supply electrical energy from PLN and 3 phase generator to operate the pump motor embedded multilevel type, capacity, Q = 30 m 3 /h; electric power, PN = 4 kW; voltage, 380V/3-/50Hz, and Y connections that can be operated manually or automatically by using the automatic transfer switch. The results obtained recapitulation total load of 4 kW, the magnitude of the nominal current of 9.5 A; kind of safety and capacity are used NFB 16 A, use of this type of cable to the control panel is PLN NYY 6 mm 2 diameter maximum current capacity of 25 A cable and use the control panel to the pump motor cable type NYY 4 mm 2 diameter maximum current capacity of 20 A. The design of the pump motor control system installation is ready to be implemented. (author)

  14. Development of the multipurpose reactor G.A. Siwabessy (MPR-GAS)

    International Nuclear Information System (INIS)

    Handoyo, Demon; Deswandri; Mulyanto, Dwijo; Kusmono, Slamet

    1998-01-01

    To analyze the reliability of its components, the development of the Multi Purposes Reactor G.A. Siwabessy (MPR-GAS) data base has been done. The analysis was done base on the components operating experiences and the data collection from the operation data have been collected from February 1997 to January 1998. Only 22 components could be analyzed since these components operation cycles were shows very complete. The operation data provide values, such as; the operation time of components, number of failure, number of demand and number of failure on demand. The reliability parameters of the components were calculated using these values. In the calculation, the components were classified by the operating components, which gave a operation failure rate and the standby components, which gave a failure probability on demand. On calculating these parameters, not only the 1997/1998 data were used but also the past data (since September 1990), because the reliability are a cumulative value. Number of operation failure rate of components in 1997∼1998 are FAK=1,08 10 - 4 hr - 1, JE=2,53 10 - 4 hr - 1, KBE01=2,28 10 - 5 hr - 1, KBE02=3,72 10 - 5 hr - 1, PA-AP=3,01 10 - 4 hr - 1, PA A H=4,66 10 - 4 hr - 1

  15. Preliminary experience and near future utilization programmes of the MPR-30 fueled by LEU [low enriched uranium

    International Nuclear Information System (INIS)

    Arbie, B.; Soentono, S.

    1987-01-01

    The MTR type reactor MPR-30 G.A. Siwabessy, located at PUSPIPTEK Serpong has recently reached its first criticality. This multipurpose reactor is supposed to be the first MTR type reactor in the world that is designed and constructed to be fueled by low enriched uranium. Preliminary experience covering the approach to the first criticality and the excess reactivity loading as well as some thermal hydraulics and power ascension tests are briefly presented and discussed. The near future utilization programmes during and after commissioning are also presented. (Author)

  16. Analysis Of Primary Coolant Suction Side Pressure In The Delay Chamber Of The RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto

    2000-01-01

    Delay chamber is a tank to delay flow that located in the primary cooling suction side of RSG-GAS. A void occurred when operation reactor caused by too high the delta P at inlet suction pump. The condition may be avoided by using one line mode of the cooling flow. The analysis show that void volume in the delay chamber is occurred because the coolant negative pressure lowers the saturation pressure should be avoided though decreasing the delta P until about 0.1 bar at about 45 exp 0 C. Solution suggested are to use bypass flow from the spent fuel to the delay chamber. Coolant temperature can be also decreased by decreasing the power level of the reactor as well as improving the heat exchanger and cooling tower performances

  17. ANALISIS PENGARUH IRADIASI FLUENS NEUTRON CEPAT TERHADAP BERILIUM REFLEKTOR REAKTOR RSG-GAS

    Directory of Open Access Journals (Sweden)

    Sri Kuntjoro

    2015-04-01

    Full Text Available Telah dilakukan analisis iradiasi fluens neutron cepat terhadap berilium reflektor reaktor RSG-GAS. Analisis dilakukan dengan cara melakukan pengukuran fluks neutron di posisi berilium elemen dan berilium blok yang berfungsi sebagai reflector. Selanjutnya dilakukan perhitungan untuk menentukan apakah ada pengaruh fluens neutron selama berilium berada di teras reaktor. Selain cara tersebut dilakukan pula visualisasi untuk memastikan ada tidaknya deformasi pada berilium akibat iradiasi. Hasil pengukuran fluks dan fluens neutron cepat maksimal pada daya 200 kW untuk berilium elemen posisi E-2 sebesar 2,30E+07 n/cm2s dan 4,19E+17 n/cm2, J-8 sebesar 3,70E+07 n/cm2s dan 6,74E+17 n/cm2. Hasil pengukutan pada posisi B-3 sebesar 2,19E+12 n/cm2s dan 3,99E+22 n/cm2, G-10 sebesar 2,12E+12 n/cm2s dan 3,86E+22 n/cm2, serta berilium blok posisi (5-6 sebesar 5,02E+07 n/cm2s dan 9,15E+17 n/cm2, (C-D sebesar 2,32E+07 n/cm2s dan 4,23E+17 n/cm2. Deformasi yang diperoleh untuk berilium elemen (∆L/L posisi E-2 sebesar 1,12E-08, J-8 sebesar 1,84E-08, B-3 sebesar 1,60E-03, posisi G-10 sebesar 1,55E-03, sedangkan pada berilium blok di posisi 5-6 sebesar 2,52E-08 dan C-D sebesar 1,13E-08. Dari hasil ini disimpulkan tidak terjadi deformasi pada berilium elemen dan berilium blok. Hasil ini dibuktikan pula dari pengamatan visual, dimana tidak terlihat adanya deformasi pada berilium tersebut. Kata kunci : fluks, fluens, berilium elemen, berilium blok   Analysis of influence fast neutron fluence irradiated to the RSG-GAS beryllium reflector have been done. Methods of analysis was carried out by measuring fluxs neutron in beryllium element and block positio that function as reflector. The calculation done for determination it is there any influence of neutron as long as beryllium in the core. Bisede that, visualization done to make sure it there is any deformation at beryllium as efect of irradiation. Fluxs and fluences of beryllium element measurement result in 200 k

  18. Modification of fuel failure detection system at multi-purpose reactor RSG-GAS, BATAN

    International Nuclear Information System (INIS)

    Haruyama, Mitsuo; Shitomi, Hajime; Nakamura, Kiyoshi

    2003-03-01

    As one of the technical cooperation activity based on the Annex III, the Cooperation in the Area of Reactor Physics and Technology, of the Arrangement between the National Energy Agency (BATAN) and the Japan Atomic Energy Research Institute (JAERI), the modification of the Fuel Failure Detection System (FFDS) was carried out by the joint work at the Multi-purpose Reactor RSG-G.A. Siwabessy (RSG-GAS). The system takes the delayed neutron detection method. In normal state, as the background, it measures the gloss delayed neutron concentration emitted in the primary coolant from the fission product (FP) nuclides, which are resulted from a very small amount of fissile material contamination on the fuel plate surface at the fabrication process. When a failure happened at fuel cladding, FP leaks from the fuel meat into the primary coolant. The system shows so higher indication than at normal state, then, the fuel failure can be detected at the early stage and be minimized the damages to the reactor facility and to the environment. The system has been installed at first since November 1994 and applied for reactor operation. However, recently it is not easy to maintain the system for aging degradation and shortage of the spare units and the parts difficult to find in the markets. The modification of FFDS is required for safe and steady reactor operation. The design requirements of the modification are, - To save the system units currently used and the spares on hand as long as practicable, and/or - To replace the system units with those easy to maintain or to obtain at the markets. The modified system obtained around twice of higher sensitivity for delayed neutron detection than before and more reliable monitoring possibility with redundancy. The specification, installation, adjustment methods and characteristics of the modified system and the modus operandi of FFDS at high power reactor operation are described in this paper. (author)

  19. Safety assessment of the Indonesian multipurpose reactor RSG-GAS against ATWS and hypothetical accidents

    International Nuclear Information System (INIS)

    Hastowo, H.; Nabbi, R.; Prayoto; Ismuntoyo, R.P.H.

    2004-01-01

    Investigation on ATWS and hypothetical accidents for the Indonesian Multipurpose Reactor RSG-GAS have been undertaken by computer simulation technique. Two computer codes, namely RELAP5 and PARET-ANL, were used as the main tools. The RELAP5 was utilized to perform system analysis while the PARET-ANL code was used to perform the reactor core analysis in more detail. Two different models have been applied as a basis of the simulation: Typical Working Core model (IWC-model) consisting of four regions with different radial power factors; and the hot-channel model consisting of two regions with different radial power factors. Both RELAP5 ad PARET-ANL results showed that in the occurrence of ATWS, failure on fuel element or fuel plate was limited to the region with the most highest power factor. The results also indicated that no high pressure development occurs in that region, so that mechanical damage on the fuel element or other core components due to pressure shock did not happen.(author)

  20. Sensitivity analysis of power excursion in RSG-GAS reactor due to reactivity insertion

    International Nuclear Information System (INIS)

    Pinem, Surian; Sembiring, Tagor Malem

    2002-01-01

    Reactor kinetics has a very important role in reactor operation safety and nuclear reactor control. One of the important aspects in reactor kinetics is power behavior as function of time due to chain reaction in the core. The calculation was performed using kinetic equation and feedback reactivity and evaluated using static power coefficient. Analysis was performed for oxide 250 g, silicide 250 g and silicide 300 g fuel elements with insertion of positive reactivity, negative reactivity and reactivity close to delay neutron fraction. The calculation of power excursion sensitivity showed that the insertion of 0,5 % Δk/k, in the fuel element of silicide 300 g is bigger 5 % than the one of oxide 250 g or silicide 250 g. If inserted by - 1,2 % Δk/k, there is no change among three fuel elements. Therefore, in kinetic point of view, it is showed there is no significant influence in the RSG-GAS reactor operation safety is the current core of oxide 250 g is converted to silicide 250 g or to silicide 300 g

  1. Effect of Utilization of Silicide Fuel with the Density 4.8 gU/cc on the Kinetic Parameters of RSG-GAS Reactor

    International Nuclear Information System (INIS)

    Setiyanto; Sembiring, Tagor M.; Pinem, Surian

    2007-01-01

    Presently, the RSG-GAS reactor using silicide fuel element of 2.96 gU/cc. For increasing reactor operation time, its planning to change to higher density fuel. The kinetic calculation of silicide core with density 4.8 gU/cc has been carried out, since it has an influence on the reactor operation safety. The calculated kinetic parameters are the effective delayed neutron fraction, the delayed neutron decay constant, prompt neutron lifetime and feedback reactivity coefficient very important for reactor operation safety. the calculation is performed in 2-dimensional neutron diffusion-perturbation method using modified Batan-2DIFF code. The calculation showed that the effective delayed neutron fraction is 7. 03256x10 -03 , total delay neutron time constant is 7.85820x10 -02 s -1 and the prompt neutron lifetime is 55.4900 μs. The result of prompt neutron lifetime smaller 10 % compare with silicide fuel of 4.8 gU/cc. The calculated results showed that all of the feedback reactivity coefficient silicide core 4.8 gU/cc is negative. Totally, the feedback reactivity coefficient of silicide fuel of 4.8 gU/cc is 10% less than that of silicide fuel of 2.96 gU/cc. The results shown that kinetic parameters result decrease compared with the silicide core with density 2.96 gU/cc, but no significant influence in the RSG-GAS reactor operation. (author)

  2. Analysis Of The Heat Exchanger Capability At One Line Cooling System Operation Mode Of The RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto; Kuntoro, Iman

    2000-01-01

    In the frame of minimizing the operation lost of the RSG-GAS reactor, operation using one line cooling system at certain power range is being evaluated. Analysis the performance of cooling system for determining maximum power should be carried out. Analysis was carried out based on heat exchanger calculation using actual operation data. Constraints imposed to the analysis are that inlet cooling system to the reactor core shall be less than 42 o C. The result shows that by using one line of primary and secondary coolant flow of 1780 m exp. 3/hr and 2000 m 3 /hr and secondary coolant temperature from the cooling tower of 38 o C, the primary coolant to the core will be reach 42 o C if reactor operated at power of 16 MW

  3. CT-MPR invaluable in diagnosing odontogenic maxillary sinusitis

    International Nuclear Information System (INIS)

    Aoki, Hideaki; Shimazu, Kaoru; Kamada, Morito; Shiroyama, Akihiro; Mouri, Daisuke; Yamashita, Masashi; Kawasaki, Yasunori; Koseki, Takakazu; Mouri, Manabu

    2001-01-01

    In everyday examination, it is usual to encounter odontogenic maxillary sinusitis patients. Odontogenic maxillary sinusitis is generally best diagnosed by dental X-ray imaging. Many medical facilities not having a dental X-ray unit use coronal computed tomography (CT) images to diagnose odontogenic maxillary sinusitis. Coronal CT imaging causes artifacts, however due to dental prosthesises. Computed tomography-Multiplanar reformation (CT-MPR) imaging has proved useful in evaluating the paranasal sinus because it is not influenced by dental prosthesises. We evaluated the usefulness of CT-MPR for diagnosing odontogenic maxillary sinusitis by retrospectively analyzing 16 patients, with the following results. We couldn't diagnose all cases of odontogenic maxillary sinusitis in posteroanterior and Waters projection images. Panoramic radiography is needed to diagnose odontogenic maxillary sinusitis. Dental X-ray imaging missed some cases, but all cases were diagnosed by CT-MPR imaging, giving a 100% diagnosestic rate. CT-MPR imaging is thus at least as valuable or better than dental X-ray imaging in diagnosing odontogenic maxillary sinusitis. (author)

  4. Analysis on the Role of RSG-GAS Pool Cooling System during Partial Loss of Heat Sink Accident

    Science.gov (United States)

    Susyadi; Endiah, P. H.; Sukmanto, D.; Andi, S. E.; Syaiful, B.; Hendro, T.; Geni, R. S.

    2018-02-01

    RSG-GAS is a 30 MW reactor that is mostly used for radioisotope production and experimental activities. Recently, it is regularly operated at half of its capacity for efficiency reason. During an accident, especially loss of heat sink, the role of its pool cooling system is very important to dump decay heat. An analysis using single failure approach and partial modeling of RELAP5 performed by S. Dibyo, 2010 shows that there is no significant increase in the coolant temperature if this system is properly functioned. However lessons learned from the Fukushima accident revealed that an accident can happen due to multiple failures. Considering ageing of the reactor, in this research the role of pool cooling system is to be investigated for a partial loss of heat sink accident which is at the same time the protection system fails to scram the reactor when being operated at 15 MW. The purpose is to clarify the transient characteristics and the final state of the coolant temperature. The method used is by simulating the system in RELAP5 code. Calculation results shows the pool cooling systems reduce coolant temperature for about 1 K as compared without activating them. The result alsoreveals that when the reactor is being operated at half of its rated power, it is still in safe condition for a partial loss of heat sink accident without scram.

  5. Calculation analysis of Wims/D4-Batan-2DIFF neutron spectrum on RSG-GAS with cadmium ratio

    International Nuclear Information System (INIS)

    Radianti, I.B.; Zuhair; Hamzah, A.

    1998-01-01

    The calculation analysis of WIMS/D4-BATAN-2DIFF neutron spectrum was performed by comparison the calculation result of cadmium ratio with the experiment result on CIP, IP2, IP3 and IP4 irradiation positions of RSG GAS tenth core. The foils of Au, Mn and Co were used for determination of the measured and calculated cadmium ratios. Spectrum calculation was done in 69 energy group with 541 energy group (till 10 MeV) cross section of foil absorption reaction. The difference values between cadmium ratio calculation and experiment result for all cases were in interval of 11.0%-26.3% which are out of measurement deviation range. From these result, it concluded that the use of WIM /D4 in generating group constant is not sufficient to obtain the neutron spectrum, especially for non-fuel region

  6. Burn-Up Calculation of the Fuel Element in RSG-GAS Reactor using Program Package BATAN-FUEL

    International Nuclear Information System (INIS)

    Mochamad Imron; Ariyawan Sunardi

    2012-01-01

    Calculation of burn lip distribution of 2.96 gr U/cc Silicide fuel element at the 78 th reactor cycle using computer code program of BATAN-FUEL has been done. This calculation uses inputs such as generated power, operation time and a core assumption model of 5/1. Using this calculation model burn up for the entire fuel elements at the reactor core are able to be calculated. From the calculation it is obtained that the minimum burn up of 6.82% is RI-50 at the position of A-9, while the maximum burn up of 57.57% is RI 467 at the position of 8-7. Based on the safety criteria as specified in the Safety Analysis Report (SAR) RSG-GAS reactor, the maximum fuel burn up allowed is 59.59%. It then can be concluded that pattern that elements placement at the reactor core are properly and optimally done. (author)

  7. The Analysis of the Effect of Coolant Channel Width on Fuel Loading of the RSG-GAS Core

    International Nuclear Information System (INIS)

    Surbakti; Tukiran

    2004-01-01

    The RGS-GAS using uranium silicide fuel, plate type and 250 g U of loading is planned to increase the fuel loading to 300 g U even to 400 g U. The silicide fuel has advantages when increase the fuel loading in the same volume. Because of that case, it is necessary to analyze the effect of coolant channel width on fuel loading of the RSG-GAS core. Analyzing the effect the work which done is to generate cell and core calculation using WIMSD/4 and Batan-2DIFF codes. The WIMSD/4 code is used to generate cross section of core material and Batan-2DIFF is used to calculate the effective multiplication factor. The model that used in this calculation there are three kind of fuel loading namely, 250 g U, 300 g U and 400 g U. The coolant channel width is simulated from 1.75 mm to 2.55 mm. From that fuel loadings, it is analyzed which coolant channel width gave the best effective multiplication factor. From result of analysis showed that the best effective multiplication factor is on the coolant channel width of 2.55 mm for third of fuel loadings. (author)

  8. Analysis of Kinetic Parameter Effect on Reactor Operation Stability of the RSG-GAS Reactor

    International Nuclear Information System (INIS)

    Rokhmadi

    2007-01-01

    Kinetic parameter has influence to behaviour on RSG-GAS reactor operation. In this paper done is the calculation of reactivity curve, period-reactivity relation and low power transfer function in silicide fuel. This parameters is necessary and useful for reactivity characteristic analysis and reactor stability. To know the reactivity response, it was done reactivity insertion at power 1 watt using POKDYN code because at this level of power no feedback reactivity so important for reactor operation safety. The result of calculation showed that there is no change of significant a period-reactivity relation and transfer function at low power for 2.96 gU/cc, 3.55 gU/cc and 4.8 gU/cc density of silicide fuels. The result of the transfer function at low power showed that the reactor is critical stability with no feedback. The result of calculation also showed that reactivity response no change among three kinds of fuel densities. It can be concluded that from kinetic parameter point of view period-reactivity relation, transfer function at low power, and reactivity response are no change reactor operation from reactivity effect when fuel exchanged. (author)

  9. Synthetic display of three-dimensional CT and MPR for gastric neoplasm

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Maruyama, Masakazu

    1998-01-01

    We attempted to obtain synthesized three dimensional (3D) and MPR (Multi Planar Reconstruction) helical CT scans (3D-MPR-CT) of gastric neoplasm by using the air as a contrast medium, and we assessed the usefulness of 3D-MPR-CT gastroendoscopy in the diagnosis of gastric neoplasm. Five minutes before the scan, 20 mg Scopolamine Butylbromide (Buscopan) was injected intramuscularly to minimize gastric peristalsis. An effervescent agent (bubble-make granules) was fed to extend the stomach wall. Non-ionic contrast material (100 mL) was power injected immediately before the scan start. Axial images were obtained with an intersection gap of 5-mm, a 5-mm/sec table speed, and 1-mm reconstruction intervals. 3D-MPR-CT images were reconstructed from these images. In abdominal study, 3D-MPR-CT images enabled the visualization of neoplasm and its adjacent structures in versatile directions, including a view similar to endoscopic observation, proximal aspect of narrowing by tumor and also could get the information about invasive depth of gastric neoplasm. Reports on some clinical cases and the advantages and disadvantages of 3D-MPR-CT gastroendoscopy were discussed. (author)

  10. Criticality safety assessment on the RSG-GAS spent fuel storage for anticipating the next core conversion program

    International Nuclear Information System (INIS)

    Sembiring, Tagor Malem; Kuntoro, Iman; Zuhair; Liem, Peng Hong

    2003-01-01

    Criticality assessment on the spent fuel storage racks of the RSG-GAS multipurpose reactor has been conducted to support the undergoing core conversion program, in which higher uranium fuel densities of silicide (up to 4.8 gU.cm -3 ) and molybdenum (up to 8.3 gU.cm -3 ) fuel elements are adopted to enhance the reactor performance, core cycle length and reactor utilization. In the assessment, the k eff of the rack as a function of fuel density is calculated for fresh fuel elements which is a very conservative approach recommended by IAEA. Besides fuel densities, effects of water densities due to pool water temperature variation, and the fuel elements' orientation on the k eff are analyzed as well. The criticality calculations are all carried out by using MNCP4B2 Monte Carlo code with ENDF/B-VI library. For the library sensitivity, JENDL-3.3 library is also used and compared. The calculation results show the most reactive condition is for the case when the spent fuel racks are filled with fresh U-6Mo fuel element with meat density of 8.30 gU.cm -3 . For all fuel types, density and operating condition, the calculated k eff with 3 times standard deviations are confirmed less than the allowable value of 0.95. It can be concluded that the existing spent fuel storage racks can be safely used for storing the planned high density uranium fuels. (author)

  11. Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Yamagata, Hitoshi; Nogami, Munenobu; Kono, Atsushi; Sugimura, Kazuro

    2012-01-01

    Purpose: To evaluate potential benefits of using multiplanar reconstruction (MPR) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (MDCT). Materials and methods: MDCT datasets of 60 patients with suspected lung nodules were retrospectively collected. Using “second-read” CAD, two radiologists (Readers 1 and 2) independently interpreted these datasets for the detection of non-calcified nodules (≥4 mm) with concomitant confidence rating. They did this task twice, first without MPR (using only axial images), and then 4 weeks later with MPR (using also coronal and sagittal MPR images), where the total reading time per dataset, including the time taken to assess the detection results of CAD software (CAD assessment time), was recorded. The total reading time and CAD assessment time without MPR and those with MPR were statistically compared for each reader. The radiologists’ performance for detecting nodules without MPR and the performance with MPR were compared using jackknife free-response receiver operating characteristic (JAFROC) analysis. Results: Compared to the CAD assessment time without MPR (mean, 69 s and 57 s for Readers 1 and 2), the CAD assessment time with MPR (mean, 46 s and 45 s for Readers 1 and 2) was significantly reduced (P < 0.001). For Reader 1, the total reading time was also significantly shorter in the case with MPR. There was no significant difference between the detection performances without MPR and with MPR. Conclusion: The use of MPR has the potential to improve the workflow in CAD of lung nodules on MDCT.

  12. Construction of binary status information system using PC network

    International Nuclear Information System (INIS)

    Kurnianto, K.; Azriani, A.; Teddy, S.

    1998-01-01

    Binary status information system is a part of establishing reactor parameter with Pc that function as MPR-30 Process Computer. Binary Alarm system, consist of interface hardware and input binary module terminal, prepare the information that be displayed in text message and graphical form. Monitor software give facilities that binary status of RSG-GAS components can be monitored using computer network (LAN). This program consist of two part : reside in server computer and reside in user computer. Program in server acquire data from interface and than store it in data base (Access file). Than, user computer read this file and display it in Dynamic Process and Instrumentation Diagram. The number of user computer can be more then one because data base was designed for multi-user operation

  13. Design of Electrical System for Inhibitor Injection Pump’s Motor PAQ 01/02/03 RSG-GAS

    International Nuclear Information System (INIS)

    Taufiq, M.; Teguh Sulistyo; Kiswanto; Santosa Pujiarta

    2008-01-01

    In order to control the water quality related to the growth of scale, corrosion and micro-organism in the PA01 BR01 and PA02 BR 02 piping system of secondary cooling system of RSG-GAS, electrical systems for motor of inhibitor injection pump PAQ 01/02/03, including motor control system circuit for inhibitor injection pump PAQ02 AP01, motor control system circuit for NaOCl injection pump PAQ01 AP01, motor control system circuit for inhibitor injection pump PAQ02 AP02 and control system circuit for stir pump RW02 have been designed. Motor control system circuit for pump PAQ02 AP01 which attached at the inhibitor tank will operate when conductivity control CQ01 indicates blow down condition and pump motor PAQ02 AP02 is not operate when level control CL02 indicates minimum level. This design is expected that, NaOCl injection pump PAQ01 AP 01 will operate continuously and inhibitor injection pump PAQ02 AP02 will operate automatically. (author)

  14. Analysis Of Core Management For The Transition Cores Of RSG-GAS Reactor To Full-Silicide Core

    International Nuclear Information System (INIS)

    Malem Sembiring, Tagor; Suparlina, Lily; Tukiran

    2001-01-01

    The core conversion of RSG-GAS reactor from oxide to silicide core with meat density of 2.96 g U/cc is still doing. At the end of 2000, the reactor has been operated for 3 transition cores which is the mixed core of oxide-silicide. Based on previous work, the calculated core parameter for the cores were obtained and it is needed 10 transition cores to achieve a full-silicide core. The objective of this work is to acquire the effect of the increment of the number of silicide fuel on the core parameters such as excess reactivity and shutdown margin. The measurement of the core parameters was carried out using the method of compensation of couple control rods. The experiment shows that the excess reactivity trends lower with the increment of the number of silicide fuel in the core. However, the shutdown margin is not change with the increment of the number of silicide fuel. Therefore, the transition cores can be operated safety to a full-silicide core

  15. KEDUDUKAN KETETAPAN MPR BERDASARKAN UU NO. 12 TAHUN 2011 TENTANG PEMBENTUKAN PERATURAN PERUNDANG-UNDANGAN

    Directory of Open Access Journals (Sweden)

    Delfina Gusman

    2012-03-01

    Full Text Available MPR Decree in resettlement of legislation under the Constitution of 1945 on the basis of Law No. 12 Year 2011 cocerning formation of legislation gives rise to a variety of polemics in the position of the MPR as State institutions. Provisions of the MPR is considered to have urgency in Indonesia's system, because the MPR as State institutions is considered to still have the duty and the authority of its strategic, e.g: inauguration of President and Vice President, the establishment of the Constitution. MPR also made provisions as one of basic national legislation program.

  16. N-acetyltransferase Mpr1 confers ethanol tolerance on Saccharomyces cerevisiae by reducing reactive oxygen species

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xiaoyi [Fukui Prefectural Univ., Fukui (Japan). Dept. of Bioscience; Takagi, Hiroshi [Nara Inst. of Science and Technology, Ikoma, Nara (Japan). Graduate School of Biological Sciences

    2007-07-15

    N-Acetyltransferase Mpr1 of Saccharomyces cerevisiae can reduce intracellular oxidation levels and protect yeast cells under oxidative stress, including H{sub 2}O{sub 2}, heat-shock, or freeze-thaw treatment. Unlike many antioxidant enzyme genes induced in response to oxidative stress, the MPR1 gene seems to be constitutively expressed in yeast cells. Based on a recent report that ethanol toxicity is correlated with the production of reactive oxygen species (ROS), we examined here the role of Mpr1 under ethanol stress conditions. The null mutant of the MPR1 and MPR2 genes showed hypersensitivity to ethanol stress, and the expression of the MPR1 gene conferred stress tolerance. We also found that yeast cells exhibited increased ROS levels during exposure to ethanol stress, and that Mpr1 protects yeast cells from ethanol stress by reducing intracellular ROS levels. When the MPR1 gene was overexpressed in antioxidant enzyme-deficient mutants, increased resistance to H{sub 2}O{sub 2} or heat shock was observed in cells lacking the CTA1, CTT1, or GPX1 gene encoding catalase A, catalase T, or glutathione peroxidase, respectively. These results suggest that Mpr1 might compensate the function of enzymes that detoxify H{sub 2}O{sub 2}. Hence, Mpr1 has promising potential for the breeding of novel ethanol-tolerant yeast strains. (orig.)

  17. Usefulness of MPR images of nephrogram in ureteropelvic junction stenosis

    International Nuclear Information System (INIS)

    Usui, Nobutaka; Munechika, Hirotsugu

    2005-01-01

    The study was to see if the multi-planar reconstruction (MPR) images of nephrogram were useful to evaluate the causative lesion of ureteropelvic junction (UPJ) stenosis. Thirty-two cases with UPJ stenosis were selected retrospectively for evaluation. MPR images were compared between nephrogram and ureterogram to see which was more useful for evaluation of the causative lesion. Most of the lesions were evaluated better in nephrogram or equal to ureterogram except for one case of a small ureteral tumor. MPR images in nephrogram were useful for evaluation of crossing vessels and a ureteral tumor. Benign stricture and calculi were also confirmed by the images. (author)

  18. Mpr to Support The Sales of Ict Education

    Directory of Open Access Journals (Sweden)

    Didier Neonisa

    2010-10-01

    Full Text Available In the era of globalization the development of economy in each country is determined on how they develop and utilize Information and Communication Technology (ICT in their business activity. However, Marketing Public Relations (MPR is also the most appropriate strategy for Education institute, because in nature education institute has to create long term relationship with their student. Therefore MPR should at least encompass three disciplines of studies and professions, in which are strategic management, marketing and public relations. For BINUS Center, awareness can be gain through referral activity. Advocacy or referral have dominant effect in building trust (believe, other than that publication also play a role in creating a trustworthy image towards BINUS Center. Marketing Public Relation is an effective marketing strategy for ICT education. Based on the quantitative research the majority of BINUS Center target market is in the age bracket 18-22 years old. In correlation with that fact the qualitative research has shown that MPR is effective in supporting the enrollment decision towards BINUS Center.  

  19. Simulation Of The Secondary Cooling System Failed For One Line Mode Of RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto; Susyadi; Sembiring, Tagor M; Isnaeni, Darwis

    2003-01-01

    Recently, an assessment of 15 MW power reactor RSG-GAS operated using one line cooling mode is under carried out, in which is in the same manner as BA TAN policy. At the power above mentioned, requirement for the research as well as isotop production has been fulfilled. To obtain the transient condition of 1 line-cooling mode, the simulation using RELAP5.MOD3.2 code was carried out. The simulation parameters interesting known are the inlet of primary coolant temperature after failed the secondary cooling system. At the first, reactor is operated at 15 MW steady state condition using 1 line-cooling mode. Primary coolant flow rate of 430 kg/s and secondary of 550 kg/s respectively. After that the decreasing is occurred due to stop of secondary cooling pump. Therefore the primary cooling inlet temperature to the core increase cause scram reactor by inserted control rod. During the transient occur, the characteristic of primary cooling temperature pattern change were obtained. The simulation result shows that the temperature increase (ΔT) temperature to the reactor is 5,1 o C at the second of 85.5. Here is lower than ΔT for the two cooling mode of 10 o C. That temperature characteristic still tolerable against acceptable safety margin to the flow instability

  20. On MPR-OSPF Specification and Implementation in Quagga/GTNetS

    OpenAIRE

    Cordero , Juan Antonio

    2008-01-01

    This document analyses the MPR-OSPF current specification and compares it with the implemented version for the Quagga / Zebra routing suite, adapted for the GTNetS network simulator. It presents the relationship between Quagga/Zebra core and the GTNetS simulation framework, describes the inner architecture of the MPR-OSPF extension in the OSPF Quagga general implementation and identifies the different protocol main elements in the implemented code.

  1. Maintenance of Structures, Systems and Components of the RSG-GAS Reactor as an Implementation of BAPETEN Regulation No. 5 Year 2011

    International Nuclear Information System (INIS)

    Aep Saepudin Catur; Dede Solehudin Fauzi; Djunaidi

    2012-01-01

    Maintenance activities for structures, systems and components of the reactor, consider prerequisites for the operation of the non power reactor. This activity is intended to ensure that the structures, systems and components function properly. Implementation of reactor maintenance carried out starting from programs establishment, scheduling, maintenance accomplishment and maintenance report. This paper will describe the implementation of reactor maintenance non power as required by BAPETEN regulation no.5, year 2011. By understanding correctly of this regulation, it is expected that maintenance activity of structures, systems and components of the reactor can be successfully performed. The RSG-GAS reactor has implemented various types of reactor maintenance based on BAPETEN regulation no.5 year 2011 properly. As a result failure of the structures, systems and components of the reactor can be minimized then they can be kept reliable. (author)

  2. The sensor kinase MprB is required for Rhodococcus equi virulence.

    Science.gov (United States)

    MacArthur, Iain; Parreira, Valeria R; Lepp, Dion; Mutharia, Lucy M; Vazquez-Boland, José A; Prescott, John F

    2011-01-10

    Rhodococcus equi is a soil bacterium and, like Mycobacterium tuberculosis, a member of the mycolata. Through possession of a virulence plasmid, it has the ability to infect the alveolar macrophages of foals, resulting in pyogranulomatous bronchopneumonia. The virulence plasmid has an orphan two-component system (TCS) regulatory gene, orf8, mutation of which completely attenuates virulence. This study attempted to find the cognate sensor kinase (SK) of orf8. Annotation of the R. equi strain 103 genome identified 23 TCSs encoded on the chromosome, which were used in a DNA microarray to compare TCS gene transcription in murine macrophage-like cells to growth in vitro. This identified six SKs as significantly up-regulated during growth in macrophages. Mutants of these SKs were constructed and their ability to persist in macrophages was determined with one SK, MprB, found to be required for intracellular survival. The attenuation of the mprB- mutant, and its complementation, was confirmed in a mouse virulence assay. In silico analysis of the R. equi genome sequence identified an MprA binding box motif homologous to that of M. tuberculosis, on mprA, pepD, sigB and sigE. The results of this study also show that R. equi responds to the macrophage environment differently from M. tuberculosis. MprB is the first SK identified as required for R. equi virulence and intracellular survival. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Study for reactive power on distribution system line B RSG-GAS

    International Nuclear Information System (INIS)

    Yan Bony Marsahala

    2010-01-01

    Study for reactive power on distribution system line B RSG-GA is already done. The study intended to evaluate how much inductive load need the reactive power (positive), how much power factor, and what will be done to increase the power factor. The reactive power is the losses power, can't be changed into energy, but it is need for transmission process and it is cause the energy losses. The loads on distribution system line B consist of induction motors which are used for primary cooling system and secondary cooling system, lift, blower on cooling tower, and air condition system. Due to the motors using, the power factor are falling down to low. By the calculation results give that the inductive loads on distribution line B are 850 KVA and these loads caused the low power factor 0.80. If we want to increase the power factor up to 0.95, it is need to install the reactive loads likes capacitor bank 250 KVAR. (author)

  4. Neutronic design of mixed oxide-silicide cores for the core conversion of rsg-gas reactor

    International Nuclear Information System (INIS)

    Sembiring, Tagor Malem; Tukiran; Pinem surian; Febrianto

    2001-01-01

    The core conversion of rsg-gas reactor from an all-oxide (U 3 O 8 -Al) core, through a series of mixed oxide-silicide core, to an all-silicide (U 3 Si 2 -Al) core for the same meat density of 2.96 g U/cc is in progress. The conversion is first step of the step-wise conversion and will be followed by the second step that is the core conversion from low meat density of silicide core, through a series of mixed lower-higher density of silicide core, to an all-higher meat density of 3.55 g/cc core. Therefore, the objectives of this work is to design the mixed cores on the neutronic performance to achieve safety a first full-silicide core for the reactor with the low uranium meat density of 2.96gU/cc. The neutronic design of the mixed cores was performed by means of Batan-EQUIL-2D and Batan-3DIFF computer codes for 2 and 3 dimension diffusion calculation, respectively. The result shows that all mixed oxide-silicide cores will be feasible to achieve safety a fist full-silicide core. The core performs the same neutronic core parameters as those of the equilibrium silicide core. Therefore, the reactor availability and utilization during the core conversion is not changed

  5. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    International Nuclear Information System (INIS)

    Kronborg-Pettersson, N.

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data

  6. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kronborg-Pettersson, N

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data.

  7. Reliability Analysis Of The Multi Purposes Reactor G.A Siwabessy (MPR-GAS) Using Data Base

    International Nuclear Information System (INIS)

    Handoyo, Demon; Puradwi, I.W; Sriyono; Mulyanto, Dwijo; Kusmono, Slamet

    2000-01-01

    The analysis have been done base on component operating experiences and the data collection from the operation logbook of MPR GAS. Number of failure rate from 1990 until 1999/2000 of pumps in Fuel Storage Pool Purification System (FAK-AP) = 0,75∼2,5 10 exp.-4/hr, Primary Cooling System (JE01-AP)0,58∼7,1 10 exp.-4/hr, Primary Pool Purification System (KBE01-AP)0,2∼0,26 10 exp.-4/hr, Warm Layer System (KBE02-AP)0,8∼1,9 10 exp.-4/hr, Cooling Tower (PA/D-AH)= 0,85∼3,3 10 exp.-4/hr, Secondary Cooling System (PA-AP)0,91∼3,5 10 exp.-4/hr and Gen set (BRV)= 0,2∼2,2 10 exp.-2 /demand. The data of failure probability of pump from IAEA - TECDOC - 478 IS 1 10 exp.-6 ∼ 2.9 10 exp.-5 /hr, and of failure probability of gen set from IAEA - TECDOC -478 is 2.9 10 exp.-3 ∼ 3 10 exp.-2 /demand. From the result can be known that the estimation of number of failure rate in 1999/2000 is not so different if is compared with the last year estimation of number of failure rate

  8. Analysis of influence of fast neutron fluence irradiated to Beryllium element of The RSG-GAS reactor

    International Nuclear Information System (INIS)

    Sri Kuntjoro

    2010-01-01

    Analysis of influence fast neutron fluence irradiated to the RSG-GAS beryllium reflector have been done. Methods of analysis was carried out by measuring fluxes neutron in beryllium element and block position that function as reflector.The calculation done for determination it is there any influence of neutron as long as beryllium in the core. Besides that, visualization done to make sure it there is any deformation at beryllium as effect of irradiation. Fluxes and fluences of beryllium element measurement result in 200 kW reactor power are 2.30E+07 n/cm 2 .sec and 4.19E+17 n/cm 2 in position E-2, 3.70E+07 n/cm 2 s and 6.74E+17 n/cm 2 in position J-8, 2.19E+12 n/cm 2 s and 3.99E+22 n/cm 2 in position. Measurement results in the position B-3 are 2.12E+12 n/cm 2 s and 3.86E+22 n/cm 2 in position G-10 respectively. Other result are fluxes and fluence in beryllium block, those are 5,02E+07 n/cm 2 s and 9,15E+17 n/cm 2 in position (5-6), and 2,32E+07 n/cm 2 s and 4,23E+17 n/cm 2 in position (C-D). Deformation (L/L) results for beryllium element are 1,12E-08 in position E-2, 1,84E-08 in position J-8, 1,60E-03 in position B-3, and 1,55E-03 in position G-10. In beryllium block deformation results are 2,52E-08 in position (5-6) and 1,13E-08 in position (C-D). Those results are shown unseen deformation in beryllium element and beryllium block and demonstrably by visual observation in reactor hot cell. (author)

  9. Measuring Tools Design of Control Rods Drop Time at the RSG-GAS Based on Labview V8.5 and DAQ6009

    International Nuclear Information System (INIS)

    Heri Suherkiman; Sukino; Ranji Gusman

    2012-01-01

    The RSG-GAS reactor has 8 control rods that serve to control the rate of fission. Control rods are the most important technical safety systems and the last protective equipment to shut down the reactor in the event of abnormal incident. Testing of the control rods drop time is one way to ensure that the control rods can function in accordance with the requirements reactor operations. Existing test tools have limitations that can only measure one control rod at each measurement. Another problem is the difficulty of getting a replacement device with the same functionality in the market to replace existing tools if damaged Therefore, then we do design of control rods drop time based on Labview v8.5 and DAQ6009. The design has resulted design, components specification and programming that are expected to be applied to the manufacture of new control rods drop time measuring devices that have the same functionality as the previous tool with better facilities. (author)

  10. Calcium scoring with prospectively ECG-triggered CT: Using overlapping datasets generated with MPR decreases inter-scan variability

    International Nuclear Information System (INIS)

    Rutten, A.; Isgum, I.; Prokop, M.

    2011-01-01

    Objective: To examine the feasibility of reducing the inter-scan variability of prospectively ECG-triggered calcium-scoring scans by using overlapping 3-mm datasets generated from multiplanar reformation (MPR) instead of non-overlapping 3-mm or 1.5-mm datasets. Patients and methods: Seventy-five women (59-79 years old) underwent two sequential prospectively ECG-triggered calcium-scoring scans with 16 mm x 1.5 mm collimation in one session. Between the two scans patients got off and on the table. We performed calcium scoring (Agatston and mass scores) on the following datasets: contiguous 3-mm sections reconstructed from the raw data (A), contiguous 3-mm sections from MPR (B), overlapping 3-mm sections from MPR (C) and contiguous 1.5-mm sections from the raw data (D). To determine the feasibility of the MPR approach, we compared MPR (B) with direct raw data reconstruction (A). Inter-scan variability was calculated for each type of dataset (A-D). Results: Calcium scores ranged from 0 to 1455 (Agatston) and 0 to 279 mg (mass) for overlapping 3-mm sections (C). Calcium scores (both Agatston and mass) were nearly identical for MPR (B) and raw data approaches (A), with inter-quartile ranges of 0-1% for inter-scan variability. Median inter-scan variability with contiguous 3-mm sections (B) was 13% (Agatston) and 11% (mass). Median variability was reduced to 10% (Agatston and mass) with contiguous 1.5-mm sections (D) and to 8% (Agatston) and 7% (mass) with overlapping 3-mm MPR (A). Conclusion: Calcium scoring on MPR yields nearly identical results to calcium scoring on images directly reconstructed from raw data. Overlapping MPR from prospectively ECG-triggered scans improve inter-scan variability of calcium scoring without increasing patient radiation dose.

  11. The bacterial defensin resistance protein MprF consists of separable domains for lipid lysinylation and antimicrobial peptide repulsion.

    Directory of Open Access Journals (Sweden)

    Christoph M Ernst

    2009-11-01

    Full Text Available Many bacterial pathogens achieve resistance to defensin-like cationic antimicrobial peptides (CAMPs by the multiple peptide resistance factor (MprF protein. MprF plays a crucial role in Staphylococcus aureus virulence and it is involved in resistance to the CAMP-like antibiotic daptomycin. MprF is a large membrane protein that modifies the anionic phospholipid phosphatidylglycerol with l-lysine, thereby diminishing the bacterial affinity for CAMPs. Its widespread occurrence recommends MprF as a target for novel antimicrobials, although the mode of action of MprF has remained incompletely understood. We demonstrate that the hydrophilic C-terminal domain and six of the fourteen proposed trans-membrane segments of MprF are sufficient for full-level lysyl-phosphatidylglycerol (Lys-PG production and that several conserved amino acid positions in MprF are indispensable for Lys-PG production. Notably, Lys-PG production did not lead to efficient CAMP resistance and most of the Lys-PG remained in the inner leaflet of the cytoplasmic membrane when the large N-terminal hydrophobic domain of MprF was absent, indicating a crucial role of this protein part. The N-terminal domain alone did not confer CAMP resistance or repulsion of the cationic test protein cytochrome c. However, when the N-terminal domain was coexpressed with the Lys-PG synthase domain either in one protein or as two separate proteins, full-level CAMP resistance was achieved. Moreover, only coexpression of the two domains led to efficient Lys-PG translocation to the outer leaflet of the membrane and to full-level cytochrome c repulsion, indicating that the N-terminal domain facilitates the flipping of Lys-PG. Thus, MprF represents a new class of lipid-biosynthetic enzymes with two separable functional domains that synthesize Lys-PG and facilitate Lys-PG translocation. Our study unravels crucial details on the molecular basis of an important bacterial immune evasion mechanism and it may help

  12. The Relationship between Monetary Policy Rate (MPR) and ...

    African Journals Online (AJOL)

    Government in a bid to regulate the affairs of the economy would always use MPR as one of its instruments; which is an interest rate at which CBN lends to commercial banks and other clients. The execution of one of these instruments at time causes others to response either positively or negatively. In order to find out some ...

  13. Evaluation of portosystemic collaterals by MDCT-MPR imaging for management of hemorrhagic esophageal varices

    International Nuclear Information System (INIS)

    Kodama, Hideaki; Aikata, Hiroshi; Takaki, Shintaro; Azakami, Takahiro; Katamura, Yoshio; Kawaoka, Tomokazu; Hiramatsu, Akira; Waki, Koji; Imamura, Michio; Kawakami, Yoshiiku; Takahashi, Shoichi; Toyota, Naoyuki; Ito, Katsuhide; Chayama, Kazuaki

    2010-01-01

    Objective: To study the correlation between changes in portosystemic collaterals, evaluated by multidetector-row computed tomography imaging using multiplanar reconstruction (MDCT-MPR), and prognosis in patients with hemorrhagic esophageal varices (EV) after endoscopic treatment. Methods: Forty-nine patients with primary hemostasis for variceal bleeding received radical endoscopic treatment: endoscopic injection sclerotherapy (EIS) or endoscopic variceal ligation (EVL). Patients were classified according to the rate of reduction in feeding vessel diameter on MDCT-MPR images, into the narrowing (n = 24) and no-change (n = 25) groups. We evaluated changes in portosystemic collaterals by MDCT-MPR before and after treatment, and determined rebleeding and survival rates. Results: The left gastric and paraesophageal (PEV) veins were recognized as portosystemic collaterals in 100 and 80%, respectively, of patients with EV on MDCT-MPR images. The rebleeding rates at 1, 2, 3, and 5 years after endoscopic treatment were 10, 15, 23, and 23%, respectively, for the narrowing group, and 17, 24, 35, and 67%, respectively, for the no-change group (P = 0.068). Among no-change group, the rebleeding rate in patients with large PEV was significantly lower than that with small PEV (P = 0.027). The rebleeding rate in patients with small PEV of the no-change group was significantly higher than that in the narrowing group (P = 0.018). There was no significant difference in rebleeding rates between the no-change group with a large PEV and narrowing group (P = 0.435). Conclusion: Changes in portosystemic collaterals evaluated by MDCT-MPR imaging correlate with rebleeding rate. Evaluation of portosystemic collaterals in this manner would provide useful information for the management of hemorrhagic EV.

  14. APLIKASI TEKNIK AAN DI REAKTOR RSG-GAS PADA PENENTUAN UNSUR ESENSIAL DAN TOKSIK DI DALAM IKAN DAN PAKAN IKAN

    Directory of Open Access Journals (Sweden)

    Saeful Yusuf

    2015-03-01

    Full Text Available Pada makalah ini diuraikan tentang aplikasi teknik AAN (Analisis Aktivasi Neutron dalam penentuan konsentrasi unsur-unsur esensial dan cemaran yang terkandung di dalam beberapa spesies ikan dan pakan ikan. Unsur-unsur esensial yang terkandung dalam pakan ikan buatan juga dianalisis untuk mengetahui pengaruhnya terhadap ikan. Penentuan unsur menggunakan teknik AAN dengan metode perbandingan dan metode k0-AAN. Sampel diiradiasi di reaktor RSG-GAS yang memiliki fluks neutron thermal 5 x 1013 n.cm-2.s-1 pada daya 15 MW. Hasil penelitian menunjukkan bahwa 12 unsur di dalam 11 spesies ikan air laut dan air tawar telah ditentukan yaitu As, Br, Cr, Co, Cs, Fe, Hg, K, Na, Rb, Se and Zn. Konsentrasi cemaran As didalam ikan laut sudah melampaui batas maksimum 1 mg/kg, sedangkan konsentrasi cemaran Hg masih dibawah batas maksimum 0,5 mg/kg, baik untuk ikan laut maupun ikan air tawar. Unsur K dan Na merupakan unsur makroesensial sedangkan unsur Cr, Co, Fe, Se and Zn adalah termasuk unsur mikroesensial. Secara umum ditunjukkan bahwa kandungan mineral didalam ikan laut lebih tinggi konsentrasinya dibandingkan ikan air tawar. Br, Cs dan Rb merupakan unsur-unsur non esensial yang teridentifikasi dalam semua ikan yang dianalisis. Penelitian terhadap pakan ikan air tawar menunjukkan bahwa semua unsur yang teridentifikasi juga terdapat di dalam ikan laut dan ikan air tawar. Hal ini menunjukkan bahwa pakan ikan berkontribusi terhadap konsentrasi unsur di dalam ikan air tawar. Kata kunci : Analisis aktivasi neutron, unsur esensial, unsur cemaran, ikan, pakan ikan   This paper reported on the application of NAA (Neutron Activation Analysis Technique in the determination of the concentration of the essential and toxic elements in some species of fish and fish feed. Determination of elements using instrumental NAA technique with comparison and k0-INAA methods. Samples were irradiated in the RSG-GAS which has a thermal neutron flux  5.0E +13 ncm-2s-1. The results

  15. Transfer of technology construction management activities to preparation of NPP development in Indonesia (an experience of multi propose reactor 30 development at Serpong)

    International Nuclear Information System (INIS)

    Utomo

    2011-01-01

    Management and development of a nuclear installation could not be separated from the role of Construction Management in the planning stages of the project start until the commissioning. On the construction of nuclear installations MPR 30 Serpong, the role of human resource of Indonesia particularly Batan has received a lot of knowledge and experiences in the development process, the ongoing process of transfer of technology from the foreign consultants (Bechtel-USA) to Batan has been conducted at the time, and at least we are able to absorb knowledge and prove it through to completion development including commissioning activities. In the course of the time human resource challenges are required to have individual skills and expertise sufficient to handle a mega project such as nuclear power plants. Construction Management is managing a major project stages from planning, construction, procurement, installation commissioning until hand over to the owner. Based on the experience of the construction of the RSG-LP, it is expected that human resources that meet to the standards required competencies for the preparation of NPP in Indonesia are fulfilled. (author)

  16. Antioxidant N-acetyltransferase Mpr1/2 of industrial baker's yeast enhances fermentation ability after air-drying stress in bread dough.

    Science.gov (United States)

    Sasano, Yu; Takahashi, Shunsuke; Shima, Jun; Takagi, Hiroshi

    2010-03-31

    During bread-making processes, yeast cells are exposed to multiple stresses. Air-drying stress is one of the most harmful stresses by generation of reactive oxygen species (ROS). Previously, we discovered that the novel N-acetyltransferase Mpr1/2 confers oxidative stress tolerance by reducing intracellular ROS level in Saccharomyces cerevisiae Sigma1278b strain. In this study, we revealed that Japanese industrial baker's yeast possesses one MPR gene. The nucleotide sequence of the MPR gene in industrial baker's yeast was identical to the MPR2 gene in Sigma1278b strain. Gene disruption analysis showed that the MPR2 gene in industrial baker's yeast is involved in air-drying stress tolerance by reducing the intracellular oxidation levels. We also found that expression of the Lys63Arg and Phe65Leu variants with enhanced enzymatic activity and stability, respectively, increased the fermentation ability of bread dough after exposure to air-drying stress compared with the wild-type Mpr1. In addition, our recent study showed that industrial baker's yeast cells accumulating proline exhibited enhanced freeze tolerance in bread dough. Proline accumulation also enhanced the fermentation ability after air-drying stress treatment in industrial baker's yeast. Hence, the antioxidant enzyme Mpr1/2 could be promising for breeding novel yeast strains that are tolerant to air-drying stress. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT

    International Nuclear Information System (INIS)

    Kimura, Mikio; Usui, Junshi; Nozawa, Takeo

    2007-01-01

    In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT). We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography(3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image. (author)

  18. [Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT].

    Science.gov (United States)

    Kimura, Mikio; Usui, Junshi; Nozawa, Takeo

    2007-03-20

    In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT) . We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography (3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image.

  19. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  20. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  1. The success of operation and utilization of the Indonesia multipurpose reactor G.A. Siwabessy

    International Nuclear Information System (INIS)

    Taryo, Taswanda; Kuntoro, Iman

    2000-01-01

    The Indonesia Multipurpose Reactor G.A. Siwabessy (RSG-GAS), operated by Multipurpose Reactor Center (MPRC/PRSG-BATAN), went its first criticality in July 1987. The reactor then achieved the power of 30 MW thermal in March 1992. Based on user requirement, the reactor is usually operated at the power of 20 MW thermal. The RSG-GAS is put to use mainly for radioisotope production, R and D on reactor safety and by using beam tubes, the reactor can also be applied for R and D on science and materials. Operation and maintenance of the reactor have been well organized due to well technical and administrative management from the top manager to all people involved in those two activities. Within their support, the RSG-GAS has occupied great advantages not only for man power development in our center but also for scientific cooperation with whoever would like to apply the RSG-GAS for R and D with mutual benefit agreement. (author)

  2. THERMAL NEUTRON FLUX MAPPING ON A TARGET CAPSULE AT RABBIT FACILITY OF RSG-GAS REACTOR FOR USE IN k0-INAA

    Directory of Open Access Journals (Sweden)

    Sutisna Sutisna

    2015-03-01

    Full Text Available Instrumental neutron activation analysis based on the k0 method (k0-INAA requires the availability of the accurate reactor parameter data, in particular a thermal neutron flux that interact with a targets inside the target capsule. This research aims to determine and map the thermal neutron flux inside the capsule and irradiation channels used for the elemental quantification using the k0-AANI. Mapping of the thermal neutron flux (фth on two type of irradiation capsule have been done for RS01 and RS02 facilities of RSG-GAS reactor. Thermal neutron flux determined using Al-0,1%Au alloy through 197Au(n,g 198Au nuclear reaction, while the flux mapping done using statistics R. Thermal neutron flux are calculated using k0-IAEA software provided by IAEA. The results showed the average thermal neutron flux is (5.6±0.3×10+13 n.cm-2.s-1; (5.6±0.4×10+13 n.cm-2.s-1; (5.2±0.4×10+13 n.cm-2.s-1 and (5.3±0.4×10+13 n.cm-2.s-1 for Polyethylene capsule of 1st , 2nd, 3rd and 4th layer respectively. In the case of Aluminum capsule, the thermal neutron flux was lower compared to that on Polyethylene capsule. There were (3.0±0.2×10+13 n.cm-2.s-1; (2.8±0.1×10+13 n.cm-2.s-1; (3.2±0.3×10+13 n.cm-2.s-1 for 1st, 2nd and 3rd layers respectively. For each layer in the capsule, the thermal neutron flux is not uniform and it was no degradation flux in the axial direction, both for polyethylene and aluminum capsules. Contour map of eight layer on polyethylene capsule and six layers on aluminum capsule for RS01 and RS02 irradiation channels had a similar pattern with a small diversity for all type of the irradiation capsule. Keywords: thermal neutron, flux, capsule, NAA   Analisis aktivasi neutron instrumental berbasis metode k0 (k0-AANI memerlukan ketersediaan data parameter reaktor yang akurat, khususnya data fluks neutron termal yang berinteraksi dengan inti sasaran di dalam kapsul target. Penelitian ini bertujuan menentukan dan memetakan fluks neutron termal

  3. MTR loop at the MPR-GA. Siwabessy reactor of Serpong Indonesia for testing of LEU fuel

    International Nuclear Information System (INIS)

    Arbie, B.; Sunaryadi, D.; Supadi, S.

    1991-01-01

    The main objective of the MTR-Loop is for testing the specimens of MTR fuel element uprated conditions with respect to the normal conditions of the reactor fuel elements. It is intended to verify the suitability of the fuel elements for operation in a research reactor under preset temperature and pressure conditions. The most important part of the MTR loop is the test section. The fuel elements to be tested are positioned in the test section. For heat removal there is a cooling water flowing through the test section. On this paper the description of the MTR-Loop is described. Installation of the MTR-Loop will be performed in the middle of 1990. In order to facilitate the investigation of fuel behaviour and performance of the new fuel elements the supporting facilities are also already available in the RSG-GAS. (orig.)

  4. Evaluation of non radiation dangerous in multipurpose reactor GAS

    International Nuclear Information System (INIS)

    Suwarto, S.

    1998-01-01

    Evaluation of the potential non irradiation dangerous in RSG-GAS included of : the fire dangerous, the chemical hazard and gas dangerous have been performed to evaluate its potential on causing the accident and evaluate the performance of the equipment to protect the accident. Evaluate the performance of the equipment to protect to accident . Evaluate to the fire dangerous performed by identified the potential dangerous of fire at each rooms and evaluate the performance of each equipment included of dry powder fire extinguishing system, hydrant system, fire detectors and alarm system. Evaluation to the chemical hazard and gas dangerous performed by identified the number and it's the management of chemical hazard in the chemical storage and laboratory. The result of evaluation included of data of the fire dangerous potential class and the performance of its equipment in each room in RSG-GAS and the data of the number and the management system of the chemical hazard and gas in chemical storage and chemical laboratory. From this evaluation it is concluded that the equipment of fire system are available to protect against the accident and the chemical hazard and gas potential are relating small, and has been managed properly

  5. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    Energy Technology Data Exchange (ETDEWEB)

    Sun Xiaoli; Liang Changhu [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China); Liu Cheng [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)], E-mail: sdsxl2005@126.com; Liu Shuwei; Deng Kai; He Jingzhen [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)

    2010-02-15

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  6. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    International Nuclear Information System (INIS)

    Sun Xiaoli; Liang Changhu; Liu Cheng; Liu Shuwei; Deng Kai; He Jingzhen

    2010-01-01

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  7. Loss of flow incident - Simulation and measurements in the MPR

    International Nuclear Information System (INIS)

    Doval, A.; Hesham Abdou

    1999-01-01

    As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous simulation results, as well as, flap valves opening time. In this way it was verified that engineering safety features worked properly. On Stage B of the Commissioning Program the upward natural convection flow was verified and results comparison against analytical calculation, showed that the reactor core was cooled within the adopted design goals. (author)

  8. Simultaneous display of MRA and MPR in detecting vascular compression for trigeminal neuralgia or hemifacial spasm: comparison with oblique sagittal views of MRI

    International Nuclear Information System (INIS)

    Arbab, A.S.; Aoki, S.; Yoshikawa, T.; Kumagai, H.; Araki, T.; Nishiyama, Y.; Nagaseki, Y.; Nukui, H.

    2000-01-01

    A new technique, simultaneous display of magnetic resonance angiography (MRA) and multiplanar reconstruction (MPR), was performed by a workstation to identify the involved vessels in patients with trigeminal neuralgia (TN) or hemifacial spasm (HFS), and the results were compared with those of oblique sagittal MRI technique. Twelve patients with either HFS or TN were prospectively assessed by simultaneous display of MRA and MPR, and oblique sagittal techniques, to point out the neurovascular compression and to identify the involved vessels. Three-dimensional (3D) time-of-flight (TOF) spoiled gradient-echo (SPGR) images were acquired to create MRA and MPR. Oblique sagittal views were also created and displayed on films. A total of 15 vessels in 12 patients were identified as compressing vessels during surgery. Simultaneous display of MRA and MPR technique pointed out the presence of vessels at and/or around root entry/exit zone (REZ) in all 12 patients, but proper identification by the name of the individual vessel was correct in 13 of 15 cases. However, oblique sagittal technique indicated the presence of vessels at and/or around REZ in 11 patients, but only 8 of 14 vessels were correctly identified. Our new method, simultaneous display of MRA-MPR, facilitated correct identification of the involved vessels compared with the oblique sagittal view method. (orig.)

  9. Specificity of RSG-1.2 peptide binding to RRE-IIB RNA element of HIV-1 over Rev peptide is mainly enthalpic in origin.

    Science.gov (United States)

    Kumar, Santosh; Bose, Debojit; Suryawanshi, Hemant; Sabharwal, Harshana; Mapa, Koyeli; Maiti, Souvik

    2011-01-01

    Rev is an essential HIV-1 regulatory protein which binds to the Rev responsive element (RRE) present within the env gene of HIV-1 RNA genome. This binding facilitates the transport of the RNA to the cytoplasm, which in turn triggers the switch between viral latency and active viral replication. Essential components of this complex have been localized to a minimal arginine rich Rev peptide and stem IIB region of RRE. A synthetic peptide known as RSG-1.2 binds with high binding affinity and specificity to the RRE-IIB than the Rev peptide, however the thermodynamic basis of this specificity has not yet been addressed. The present study aims to probe the thermodynamic origin of this specificity of RSG-1.2 over Rev Peptide for RRE-IIB. The temperature dependent melting studies show that RSG-1.2 binding stabilizes the RRE structure significantly (ΔT(m) = 4.3°C), in contrast to Rev binding. Interestingly the thermodynamic signatures of the binding have also been found to be different for both the peptides. At pH 7.5, RSG-1.2 binds RRE-IIB with a K(a) = 16.2±0.6×10(7) M(-1) where enthalpic change ΔH = -13.9±0.1 kcal/mol is the main driving force with limited unfavorable contribution from entropic change TΔS = -2.8±0.1 kcal/mol. A large part of ΔH may be due to specific stacking between U72 and Arg15. In contrast binding of Rev (K(a) = 3.1±0.4×10(7) M(-1)) is driven mainly by entropy (ΔH = 0 kcal/mol and TΔS = 10.2±0.2 kcal/mol) which arises from major conformational changes in the RNA upon binding.

  10. Secondary Cooling Water Quality Management for Multi Purpose Reactor 30 MW GA Siwabessy Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Sunaryo, Geni Rina, E-mail: genirina@batan.go.i [Center for Reactor Technology and Nuclear Safety (PTRKN-BATAN), Bldg. 80, Puspiptek Area, Serpong, Tangerang 15310 (Indonesia)

    2011-07-01

    Indonesia Multi Purpose Research Reactor (MPR) G.A. Siwabessy 30 MW will be 25 years old in 2011. Series of Non Destructive Test (NDT) were done to understand the current condition such as Eddy Current test for Heat Exchangers, water immersed camera for understanding the tank liner condition, ultrasonic for secondary piping etc. Some deteorization was observed because of ageing and some changing was done. One of them is changing some part of secondary pipe lines because of leaking, with the local ones. For having another 25 years operation life, a proper water quality for secondary cooling water is needed towards corrosion prevention. The main objectives of this experiment is to understand the current water quality of secondary cooling water of RSG-GAS from the aspect of corrosion induced by chemicals and bacteria, and establish procedure for managing the secondary cooling water quality. Methodologies applied are surveillance corrosion by immersing coupon into water observed and followed by visual analyses, corrosion rate determination by electrochemical method with various chemical conditions and total bacteria determination by using test kit. The results show visually that the crevice, galvanic and homogeny corrosion with the current water quality easily be observed for carbon steel represented secondary pipelines at the condition of none oxy bio agent addition. This corrosion is being suppressed by adding the oxy bio agent. The orientation of coupon, vertically and horizontally, gives slightly different effect. The closely corrosion rate was obtained by separately experiment, electrochemical, at the concentration of inhibitor 100ppm is 0.13 {+-} 0.02, which is lower than in the raw water of 0.20 {+-} 0.01 mpy. The total bacteria detected is around 10{sup 7} cfu/ml at none reactor operation and without any anti bacteria added. The oxi bio agent chemical addition suppresses the numbers becomes 10{sup 3} cfu/ml. The SRB bacteria is detected as >10{sup 6} cfu/ml at

  11. Achieving scale-independent land-surface flux estimates - Application of the Multiscale Parameter Regionalization (MPR) to the Noah-MP land-surface model across the contiguous USA

    Science.gov (United States)

    Thober, S.; Mizukami, N.; Samaniego, L. E.; Attinger, S.; Clark, M. P.; Cuntz, M.

    2016-12-01

    Land-surface models use a variety of process representations to calculate terrestrial energy, water and biogeochemical fluxes. These process descriptions are usually derived from point measurements but are scaled to much larger resolutions in applications that range from about 1 km in catchment hydrology to 100 km in climate modelling. Both, hydrologic and climate models are nowadays run on different spatial resolutions, using the exact same land surface representations. A fundamental criterion for the physical consistency of land-surface simulations across scales is that a flux estimated over a given area is independent of the spatial model resolution (i.e., the flux-matching criterion). The Noah-MP land surface model considers only one soil and land cover type per model grid cell without any representation of subgrid variability, implying a weak flux-matching. A fractional approach simulates subgrid variability but it requires a higher computational demand than using effective parameters and it is used only for land cover in current land surface schemes. A promising approach to derive scale-independent parameters is the Multiscale Parameter Regionalization (MPR) technique, which consists of two steps: first, it applies transfer functions directly to high-resolution data (such as 100 m soil maps) to derive high-resolution model parameter fields, acknowledging the full subgrid variability. Second, it upscales these high-resolution parameter fields to the model resolution by using appropriate upscaling operators. MPR has shown to improve substantially the scalability of hydrologic models. Here, we apply the MPR technique to the Noah-MP land-surface model for a large sample of basins distributed across the contiguous USA. Specifically, we evaluate the flux-matching criterion for several hydrologic fluxes such as evapotranspiration and total runoff at scales ranging from 3 km to 48 km. We also investigate a p-norm scaling operator that goes beyond the current

  12. Nuclear data and reactor physics activities in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Liem, P.H. [National Atomic Energy Agency, Tangerang (Indonesia). Center for Multipurpose Reactor

    1998-03-01

    The nuclear data and reactor physics activities in Indonesia, especially, in the National Atomic Energy Agency are presented. In the nuclear data field, the Agency is now taking the position of a user of the main nuclear data libraries such as JENDL and ENDF/B. These nuclear data libraries become the main sources for producing problem dependent cross section sets that are needed by cell calculation codes or transport codes for design, analysis and safety evaluation of research reactors. In the reactor physics field, besides utilising the existing core analysis codes obtained from bilateral and international co-operation, the Agency is putting much effort to self-develop Batan`s codes for reactor physics calculations, in particular, for research reactor and high temperature reactor design, analysis and fuel management. Under the collaboration with JAERI, Monte Carlo criticality calculations on the first criticality of RSG GAS (MPR-30) first core were done using JAERI continuous energy, vectorized Monte Carlo code, MVP, with JENDL-3.1 and JENDL-3.2 nuclear data libraries. The results were then compared with the experiment data collected during the commissioning phase. Monte Carlo calculations with both JENDL-3.1 and -3.2 libraries produced k{sub eff} values with excellent agreement with experiment data, however, systematically, JENDL-3.2 library showed slightly higher k{sub eff} values than JENDL-3.1 library. (author)

  13. Determination of Source Term for an Annual Stack Release of Gas Reactor G.A. Siwabessy

    International Nuclear Information System (INIS)

    Sudiyati; Syahrir; Unggul Hartoyo; Nugraha Luhur

    2008-01-01

    Releases of radionuclide from the reactor are noble gases, halogenides and particulates. The measurements were carried out directly on the air monitoring system of the stack. The results of these measurements are compared with the annual Source-Term data from the Safety Analyses report (SAR) of RSG-GAS. The measurement results are smaller than the data reported in SAR document. (author)

  14. Progress in the development of uranium silicide (U3Si2) fuel at BATAN

    International Nuclear Information System (INIS)

    Suripto, A.; Soentono, S.

    1995-01-01

    After successful fabrication of two full-size prototype fuel elements containing ∼3.0 gU/cm 3 in the form of U 3 Si 2 -Al dispersion now undergoing irradiation in the Reaktor Serba Guna G.A. Siwabessy (RSG-GAS) core since 1990, further development in U 3 Si 2 -A2 dispersion fuel element manufacturing has been pursued, whose progress in discussed in this paper, with a special attention on the use of much higher-loading aimed at obtaining a better understanding on the influence of higher-loading on fuel core and plate manufacturing and quality. At present, high-loading U 3 Si 2 -AI dispersion miniplates are being manufactured for preparing some mini-fuel elements to be test-irradiated in the new MTR in-pile loop of the RSG-GAS. (author)

  15. 30 CFR 36.26 - Composition of exhaust gas.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Composition of exhaust gas. 36.26 Section 36.26... EQUIPMENT Construction and Design Requirements § 36.26 Composition of exhaust gas. (a) Preliminary engine... methane) is a satisfactory substitute for pure methane in these tests. (c) Coupling or adapter. The...

  16. 30 CFR 203.73 - How do suspension volumes apply to natural gas?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do suspension volumes apply to natural gas... suspension volumes apply to natural gas? You must measure natural gas production under the royalty-suspension volume as follows: 5.62 thousand cubic feet of natural gas, measured in accordance with 30 CFR part 250...

  17. The Selection Method of RCM in the Primary Cooling System of RSG GA. Siwabessy Related to Functions as the Primary Cooling Reactor RSG GA. Siwabessy

    International Nuclear Information System (INIS)

    Mohammad Tahril Azis; Salman Suprawhardana, M.; Teguh Pudji Purwanto

    2010-01-01

    Reactor RSG GA. Siwabessy to ensure the temperature inside the reactor core and reflectors within the limits of allowable operations during reactor operation. The primary cooling system components must refer to the thermal power reactors and to minimize failure probability of components to operate the reactor in safe and secure. The RCM Method Development (Reliability Centered Maintenance) with a web-based Free Open Source Software (FOSS)/GPL (General Public License), will assist the maintenance support information system that can work in the intranet / internet. Free Open Source Software (FOSS) is software that can provide assurance to the user to perform the development, sharing and make changes if necessary, especially users feel confident that the software actually legal and free (free software). The RCM method recommends maintenance types of 52 task selection to be applied in the primary cooling system with details time directed (td) 35% (18 tasks), condition directed (cd) 63% (33 tasks) and 1% failure finding (1 task). (author)

  18. 30 CFR 250.119 - Will MMS approve subsurface gas storage?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Will MMS approve subsurface gas storage? 250....119 Will MMS approve subsurface gas storage? The Regional Supervisor may authorize subsurface storage of gas on the OCS, on and off-lease, for later commercial benefit. To receive MMS approval you must...

  19. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Determination of exhaust-gas composition. 36.43... TRANSPORTATION EQUIPMENT Test Requirements § 36.43 Determination of exhaust-gas composition. (a) Samples shall be..., hydrogen, methane, nitrogen, oxides of nitrogen, and aldehydes, or any other constituent prescribed by MSHA...

  20. Operation and utilization of Indonesia Research Reactors

    International Nuclear Information System (INIS)

    Kuntoro, Iman; Sujalmo, Saiful; Tarigan, Alim

    2004-01-01

    For supporting the R and D in nuclear science and technology and its application, BATAN own and operate three research reactors namely, TRIGA-2000, KARTINI and RSG-GAS having thermal power of 2 MW, 100 kW and 30 MW respectively. The main features, operation and utilization progress of the reactors are described in this report. (author)

  1. 30 CFR 250.1157 - How do I receive approval to produce gas-cap gas from an oil reservoir with an associated gas cap?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I receive approval to produce gas-cap gas from an oil reservoir with an associated gas cap? 250.1157 Section 250.1157 Mineral Resources... do I receive approval to produce gas-cap gas from an oil reservoir with an associated gas cap? (a...

  2. High precision localization of intracerebral hemorrhage based on 3D MPR on head CT images

    Science.gov (United States)

    Sun, Jianyong; Hou, Xiaoshuai; Sun, Shujie; Zhang, Jianguo

    2017-03-01

    The key step for minimally invasive intracerebral hemorrhage surgery is precisely positioning the hematoma location in the brain before and during the hematoma surgery, which can significantly improves the success rate of puncture hematoma. We designed a 3D computerized surgical plan (CSP) workstation precisely to locate brain hematoma based on Multi-Planar Reconstruction (MPR) visualization technique. We used ten patients' CT/MR studies to verify our designed CSP intracerebral hemorrhage localization method. With the doctor's assessment and comparing with the results of manual measurements, the output of CSP WS for hematoma surgery is more precise and reliable than manual procedure.

  3. Tooth axis and skeletal structures in mandibular molar vertical sections in jaw deformity with facial asymmetry using MPR images

    International Nuclear Information System (INIS)

    Nojima, Kunihiko; Yokose, Taishi; Ishii, Takenobu; Kobayashi, Makoto; Nishii, Yasushi

    2007-01-01

    The objective of the present study was to investigate frontal morphological asymmetry in the mandibular molar region in terms of tooth axis and skeletal structures using vertical MPR sections in jaw deformity accompanied by facial asymmetry. Subjects consisted of 15 patients with jaw deformity accompanied by facial asymmetry aged 17.4 years to 37.8 years. There were four men and eleven women. Based on X-ray computed tomography (CT) scans, Digital Imaging and Communications in Medicine (DICOM) viewer software was used to prepare multiplanar reconstruction (MPR) sections. The mandible was then positioned on a reference plane based on the menton and left and right gonions, and a vertical MPR section passing through the mesial root of the first mandibular molar was prepared. The following measurements were made on both the shifted and non-shifted sides: maximum buccolingual width of the mandibular body; height of the mandibular body; inclination angle of the mandibular body; degree of buccal protrusion of the mandibular body; and inclination angle of the buccolingual tooth axis of the first molar. Furthermore, degree of median deviation in the menton was measured using frontal cephalograms. Differences in morphological parameters between the shifted and non-shifted sides were assessed. Furthermore, the relationship between median deviation and asymmetry were statistically analyzed. There was no significant asymmetry in the maximum buccolingual width of the mandibular body, the height of the mandibular body or the degree of buccal protrusion of the mandibular body. However, when compared to the shifted side, the inclination angle of the buccolingual tooth axis of the first molar for the non-shifted side was significantly greater. There was a relatively strong correlation between median deviation and inclination angle of the mandibular body. The above findings clarified that, in orthognathic surgery for jaw deformity accompanied by facial asymmetry, actively improving

  4. Core conversion study from silicide to molybdenum fuel in the Indonesian 30 MW multipurpose reactor G.A. Siwabessy (RSG-GAS)

    International Nuclear Information System (INIS)

    Sembiring, T.M.; Kuntoro, I.

    2005-01-01

    This paper describes the core conversion from silicide to molybdenum core through a series of silicide (2.96 gU cm -3 ) - molybdenum (3.55 gUcm -3 ) mixed transition cores for the Indonesian 30 MW-Multipurpose G.A. Siwabessy (RSGGAS) reactor. The core calculations are carried out using the two-dimensional multigroup neutron diffusion method code of Batan-EQUIL-2D. The calculated results showed that the proposed silicide-molybdenum mixed transition cores, using the same refueling/reshuffling scheme, meet the safety criteria and it can be used in safely converting from an all-silicide core to an all-molybdenum core. (author)

  5. Multi-Detector CT Findings of the Normal Appendix in Children: Evaluation of the Position, Diameter, and Presence or Absence of Intraluminal Gas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Woon Ju; Kim, Jong Chul [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2011-08-15

    To assess the usefulness of multi-detector CT (MDCT) with multiplanar reformations (MPR) for the evaluation of the position, diameter and presence or absence of intraluminal gas in the normal appendix in children. From 2007 to 2010, we retrospectively analyzed the MDCT images of normal appendices in 133 children, and evaluated the position, diameter, and presence or absence of intraluminal gas in the appendix. Among the 133 appendices, type I (postileal and medial paracecal position) was found in 64 children, type II (subcecal position) in 22, type III (retrocecal and retrocolic/laterocolic position) in 15, type IV (preileal and medial colic position) in 16, and type V (lower pelvic position) in 16 children. The mean diameter was 5.8 mm {+-} 1.2 (SD) (range; 3.2-8.7 mm). There was a high correlation between the appendiceal diameter and age (p = 0.000).There was no statistically significant difference in the appendiceal diameter between boys and girls (p = 0.470). Intraluminal gas was found in 115 appendices and there was no statistically significant correlation between the appendiceal diameter and intraluminal gas (p = 0.502). The MDCT with MPR was useful for the evaluation of the normal appendices in children. The procedure may be useful for the diagnosis of equivocal or unusual appendicitis in children.

  6. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  7. 30 CFR 250.123 - Will MMS allow gas storage on unleased lands?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Will MMS allow gas storage on unleased lands? 250.123 Section 250.123 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR... § 250.123 Will MMS allow gas storage on unleased lands? You may not store gas on unleased lands unless...

  8. Let us talk about shale gas in 30 questions

    International Nuclear Information System (INIS)

    Bauquis, Pierre-Rene

    2014-01-01

    The author addresses and gives an overview of the issue of shale gas extraction and production by answering 30 questions. These questions concern the origins of hydrocarbons, the definition of shale gas and oil, how gases and oils are produced from source rocks, the principle of hydraulic fracturing, where and how to perform this fracturing, the issue of water wastage, the risks of water pollution, seismic risks, nuisances for the neighbourhood, alternatives to hydraulic fracturing, production technical and economic characteristics, the issue of production profitability, economic benefits in the USA, impacts on the world refining industry, the possibility of creation of a new bubble, the role played by US authorities, the US shale oil and gas production, the technical potential outside the USA, the French resources, the stakes for the French economy, the macro-economic and geo-strategic impacts, the consequences for climate change, impacts on the world energy production

  9. Digital reactivity meter construction based on PC

    International Nuclear Information System (INIS)

    Yusi-Eko-Yulianto; Kristedjo-Kurnianto

    2003-01-01

    The reactivitymeter is a core reactivity measuring equipment, which inform the reactor operator the neutron flux development in the core. This digital reactivitymeter is needed to replace analog reactivitymeter, whenever it fails in the future. The replacement of thus reactivitymeter can keep the continuation of reactor operation. The digital reactivitymeter is constructed by using the digital signal processing and computer. Thus real time signal processing is displayed on the monitor graphically. This reactivitymeter has been tested in RSG-GAS and perform a good work. This performance is worthy to use this digital reactivitymeter for RSG-GAS operation

  10. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): Assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images

    International Nuclear Information System (INIS)

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-01-01

    Objective: The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Materials and methods: Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. Results: MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4 ± 1.1 mm, which was statistically smaller than that of 13 control patients, 6.0 ± 1.5 mm (P < 0.05, Wilcoxon rank sum tests). Conclusion: Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality.

  11. Determination of Neutron Flux Parameter f and α and k0 Factor in Irradiation Facility of RSG GA Siwabessy reactor

    International Nuclear Information System (INIS)

    Amir Hamzah

    2004-01-01

    Determination of neutron flux thermal to epithermal ratio f and parameter α and k 0 factor has been done in irradiation facility of RSG G.A. Siwabessy reactor. Those parameters are needed to determine the concentration of an element in a sample using k 0 NAA method. Parameters f was measured using foil activation method and α parameter was obtained from power function fitting at epithermal neutron spectrum. Based on the fitting method the a parameter was determined of 0.0267,0.0255 and -0.0346 at system rabbit, IP2 and CIP irradiation position. The k 0 factor is depended on absolute gamma fraction. The neutron flux thermal to epithermal ratio f at all rabbit system is closed to 40. (author)

  12. Planning and performing spine surgery with CT/MPR: A primer for radiologists

    International Nuclear Information System (INIS)

    Camp, P.; Kerber, C.W.

    1985-01-01

    Few things are more discouraging to a surgeon than the patient who has continued bitter complaints after spine surgery. We often show our discouragement by refusing even to name these patients;instead we depersonalize them, calling them ''failed backs.'' The most common cause of the failed-back syndrome is probably an error in the original decision to operate. Many patients have unsolved psychosocial problems that the surgeon may not recognize. Even though we are critical of this lapse in surgical judgment, the most experienced and cautious physician occasionally makes these mistakes. Not all failed backs are psychosocial in origin. The advent of computerized tomography with multiplanar reconstruction (CT/MPR) has demonstrated several large and important subsets of patients whose operation has failed not for psychosocial reasons but for a lack of appreciation of unrecognized pathology. In a small minority of cases, the surgeon has operated on the wrong interspace. In most, though, important pathology was overlooked and not operated on because the technology to see it was unavailable. In order that the radiologist can better understand the problems encountered by the surgeon, the authors now review the most common of these problems and outline how specific abnormalities are diagnosed and treated. The evaluation of back disease is a complex undertaking, and the partnership between radiologist and surgeon is an essential one

  13. Prompt neutron decay constant estimation of RSG-GAS at high power noise experiment

    International Nuclear Information System (INIS)

    Jujuratisbela, U.; Kristedjo; Tukiran; Pinem, S.; Iman, J.; Puryono; Sanjaya, A.; Suwarno

    1998-01-01

    The determination of prompt neutron decay constant (α) of RGS-GAS by using low power noise experiment method at the equilibrium core indicated that the result is not good. The bad result was due to the small ratio of the noise signal to background which was caused by low detector efficiency or contaminated core after long time operation. To solve the problem is tried by using noise experiment technique at high power. The voltage output of neutron detectors at power of 5, 12, and 23 MW were connected to preamplifier and filter then to the Dynamic Signal Analyzer Version-2 and then the power spectral density of each channel of JKT04 and JKT03, the cut off frequency of each channel can be determined by using linear regression technique such that the prompt neutron decay constant can be estimated

  14. The Analysis Of Spent Fuel Utilization For A Gamma Irradiator

    International Nuclear Information System (INIS)

    MS, Pudjijanto; Setiyanto

    2002-01-01

    The gamma irradiator using RSG-GAS spent fuels was analyzed. The cylindrical geometry of the irradiator was designed by locating the spent fuels the cylindrical periphery. The analysis was focused to evaluate the feasibilities of the irradiator as a fruits and vegetables irradiator. The spent fuels activities were calculated using Origen2 code, while the dose rate at the irradiation positions was determined by linear attenuation model with transport coefficient. The evaluated results showed that the cylindrical geometry of irradiators with diameter around 1-1.5 m gave the effective dose rate for fruits and vegetables preservation. It can be concluded that one can use the RSG-GAS spent fuels effectively as a gamma irradiator for certain applications

  15. Current status of neutron scattering research and accelerator technology in Indonesia

    International Nuclear Information System (INIS)

    Ridwan; Ikram, Abarul; Wuryanto

    2001-01-01

    The neutron beam generated from steady state reactor 30 MW RSG-GAS are used mainly for neutron scattering studies and isotope production. There are seven neutron scattering facilities under responsible and operated by Research and Development Center for Materials Science and Technology of National Nuclear Energy Agency (Batan) of Indonesia. In this report, current conditions of the facilities namely, DN1-M, HRPD, FCD/TD, SANS, HRSANS, TAS and NRF and research activities will be described. Also, a part of research activities by using accelerator technology at Batan-Yogyakarta will be reviewed. (author)

  16. 30 CFR 250.1203 - Gas measurement.

    Science.gov (United States)

    2010-07-01

    ... base pressure of 14.73 psia and reflect the same degree of water saturation as in the gas volume. (8... Federal production. (f) What are the requirements for measuring gas lost or used on a lease? (1) You must either measure or estimate the volume of gas lost or used on a lease. (2) If you measure the volume...

  17. From gas to stars in energetic environments: dense gas clumps in the 30 Doradus region within the Large Magellanic Cloud

    International Nuclear Information System (INIS)

    Anderson, Crystal N.; Meier, David S.; Ott, Jürgen; Hughes, Annie; Wong, Tony; Looney, Leslie; Henkel, Christian; Chen, Rosie; Indebetouw, Remy; Muller, Erik; Pineda, Jorge L.; Seale, Jonathan

    2014-01-01

    We present parsec-scale interferometric maps of HCN(1-0) and HCO + (1-0) emission from dense gas in the star-forming region 30 Doradus, obtained using the Australia Telescope Compact Array. This extreme star-forming region, located in the Large Magellanic Cloud (LMC), is characterized by a very intense ultraviolet ionizing radiation field and sub-solar metallicity, both of which are expected to impact molecular cloud structure. We detect 13 bright, dense clumps within the 30 Doradus-10 giant molecular cloud. Some of the clumps are aligned along a filamentary structure with a characteristic spacing that is consistent with formation via varicose fluid instability. Our analysis shows that the filament is gravitationally unstable and collapsing to form stars. There is a good correlation between HCO + emission in the filament and signatures of recent star formation activity including H 2 O masers and young stellar objects (YSOs). YSOs seem to continue along the same direction of the filament toward the massive compact star cluster R136 in the southwest. We present detailed comparisons of clump properties (masses, linewidths, and sizes) in 30Dor-10 to those in other star forming regions of the LMC (N159, N113, N105, and N44). Our analysis shows that the 30Dor-10 clumps have similar masses but wider linewidths and similar HCN/HCO + (1-0) line ratios as clumps detected in other LMC star-forming regions. Our results suggest that the dense molecular gas clumps in the interior of 30Dor-10 are well shielded against the intense ionizing field that is present in the 30 Doradus region.

  18. HTGR gas turbine program. Semiannual progress report, April 1-September 30, 1978

    International Nuclear Information System (INIS)

    1979-12-01

    This report describes work performed under the gas turbine HTGR (HTGR-GT) program, Department of Energy Contract DE-AT03-76-SF70046, during the period April 1, 1978 through September 30, 1978. The work reported covers the demonstration and commercial plant concept studies including plant layout, heat exchanger studies, turbomachine studies, systems analysis, and reactor core engineering

  19. Current status of production and supply of molybdenum-99 and 99Mo/99mTc generators in Indonesia

    International Nuclear Information System (INIS)

    Mutalib, A.

    2003-01-01

    Production of high-specific activity molybdenum-99 and 99 Mo/ 99m Tc Generators in Indonesia commenced when a new production facility supported by the presence of a 30 MW multipurpose reactor (RSG-GAS) was established in Serpong in 1990. This report describes the current production and supply of molybdenum-99m devoted mainly to fulfill the domestic demands in supplying 99 Mo/ 99m Tc Generators. Recent development on the use of LEU (Low Enriched Uranium) targets for replacing current HEU (High Enriched Uranium) targets in the production of 99 Mo will be reviewed briefly. (author)

  20. Measures of methane production and their phenotypic relationships with dry matter intake, growth, and body composition traits in beef cattle.

    Science.gov (United States)

    Herd, R M; Arthur, P F; Donoghue, K A; Bird, S H; Bird-Gardiner, T; Hegarty, R S

    2014-11-01

    Ruminants contribute up to 80% of greenhouse gas (GHG) emissions from livestock, and enteric methane production by ruminants is the main source of these GHG emissions. Hence, reducing enteric methane production is essential in any GHG emissions reduction strategy in livestock. Data from 2 performance-recording research herds of Angus cattle were used to evaluate a number of methane measures that target methane production (MPR) independent of feed intake and to examine their phenotypic relationships with growth and body composition. The data comprised 777 young bulls and heifers that were fed a roughage diet (ME of 9 MJ/kg DM) at 1.2 times their maintenance energy requirements and measured for MP in open circuit respiration chambers for 48 h. Methane traits evaluated included DMI during the methane measurement period, MPR, and methane yield (MY; MPR/DMI), with means (± SD) of 6.2 ± 1.4 kg/d, 187 ± 38 L/d, and 30.4 ± 3.5 L/kg, respectively. Four forms of residual MPR (RMP), which is a measure of actual minus predicted MPR, were evaluated. For the first 3 forms, predicted MPR was calculated using published equations. For the fourth (RMPR), predicted MPR was obtained by regression of MPR on DMI. Growth traits evaluated were BW at birth, weaning (200 d of age), yearling age (400 d of age), and 600 d of age, with means (± SD) of 34 ± 4.6, 238 ± 37, 357 ± 45, and 471 ± 53 kg, respectively. Body composition traits included ultrasound measures (600 d of age) of rib fat, rump fat, and eye muscle area, with means (± SD) of 3.8 ± 2.6 mm, 5.4 ± 3.8 mm, and 61 ± 7.7 cm(2), respectively. Methane production was positively correlated (r ± SE) with DMI (0.65 ± 0.02), MY (0.72 ± 0.02), the RMP traits (r from 0.65 to 0.79), the growth traits (r from 0.19 to 0.57), and the body composition traits (r from 0.13 to 0.29). Methane yield was, however, not correlated (r ± SE) with DMI (-0.02 ± 0.04) as well as the growth (r from -0.03 to 0.11) and body composition (r from 0

  1. The Sorption Of 137-Cs and 60-Co by RSG-LP Surface Soil And By The Sediment Of Cisadane River

    International Nuclear Information System (INIS)

    Lubis, E.

    1990-01-01

    Investigations on the sorption of 137-Cs and 60-Co by the RSG-LP surface soil and by the sediment of the Cisadane river have been carried out. In these experiments, the soil and the sediment were immersade in aqueous solution that was contaminated with 137-Cs and 60-Co. The sorption of 137-Cs and 60-Co is known by measuring the activity of the solution. The results indicated that the concentration factors (Kd) of the 60-Co and 137-Cs are functions of the specific activity of the solution in steady state conditions. The equations for 60-Co in soil and sediment are Kd = 4.45 exp. (-0.292 x C) and Kd = 2.09 exp. (-0.39 x C) respectively. The aquation for 137-Cs in soil and sediment are Kd = 9.19 exp (-0.21 x C) and Kd = 18.29 exp. (-0.18 x C), respectively. (author). 5 refs, 4 figs, 4 tabs

  2. Coordinate Transcriptomic and Metabolomic Effects of the Insulin Sensitizer Rosiglitazone on Fundamental Metabolic Pathways in Liver, Soleus Muscle, and Adipose Tissue in Diabetic db/db Mice

    Directory of Open Access Journals (Sweden)

    Sabrina Le Bouter

    2010-01-01

    Full Text Available Rosiglitazone (RSG, developed for the treatment of type 2 diabetes mellitus, is known to have potent effects on carbohydrate and lipid metabolism leading to the improvement of insulin sensitivity in target tissues. To further assess the capacity of RSG to normalize gene expression in insulin-sensitive tissues, we compared groups of 18-day-treated db/db mice with increasing oral doses of RSG (10, 30, and 100 mg/kg/d with untreated non-diabetic littermates (db/+. For this aim, transcriptional changes were measured in liver, inguinal adipose tissue (IAT and soleus muscle using microarrays and real-time PCR. In parallel, targeted metabolomic assessment of lipids (triglycerides (TGs and free fatty acids (FFAs in plasma and tissues was performed by UPLC-MS methods. Multivariate analyses revealed a relationship between the differential gene expressions in liver and liver trioleate content and between blood glucose levels and a combination of differentially expressed genes measured in liver, IAT, and muscle. In summary, we have integrated gene expression and targeted metabolomic data to present a comprehensive overview of RSG-induced changes in a diabetes mouse model and improved the molecular understanding of how RSG ameliorates diabetes through its effect on the major insulin-sensitive tissues.

  3. 30 CFR 281.30 - Minimum royalty.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Minimum royalty. 281.30 Section 281.30 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.30 Minimum royalty...

  4. Bιβλιοκρισία: M. ALTRIPP (Ηrsg., Byzanz in Europa. Europas östliches Erbe. [BYZANTIOS. Studies in Byzantine History and Civilization 2], Turnhout 2011, ISBN 978-2-503-54153-2

    Directory of Open Access Journals (Sweden)

    Στυλιανός ΛΑΜΠΑΚΗΣ

    2014-04-01

    Full Text Available Βιβλιοκρισία: M. Altripp (Ηrsg., Byzanz in Europa. Europas östliches Erbe. Akten des Kolloquiums 'Byzanz in Europa' vom 11. bis 15. Dezember 2007 in Greifswald [BYZANTIOS. Studies in Byzantine History and Civilization 2], Turnhout 2011, σελ. X + 502, 79 πίν., ISBN 978-2-503-54153-2 (printed version- 978-2-503-54193-8 (online version.

  5. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.

    Science.gov (United States)

    Lee, Sungwon; Jee, Won-Hee; Jung, Joon-Yong; Lee, So-Yeon; Ryu, Kyeung-Sik; Ha, Kee-Yong

    2015-02-01

    Three-dimensional (3D) fast spin-echo sequence with variable flip-angle refocusing pulse allows retrospective alignments of magnetic resonance imaging (MRI) in any desired plane. To compare isotropic 3D T2-weighted (T2W) turbo spin-echo sequence (TSE-SPACE) with standard two-dimensional (2D) T2W TSE imaging for evaluating lumbar spine pathology at 3.0 T MRI. Forty-two patients who had spine surgery for disk herniation and had 3.0 T spine MRI were included in this study. In addition to standard 2D T2W TSE imaging, sagittal 3D T2W TSE-SPACE was obtained to produce multiplanar (MPR) images. Each set of MR images from 3D T2W TSE and 2D TSE-SPACE were independently scored for the degree of lumbar neural foraminal stenosis, central spinal stenosis, and nerve compression by two reviewers. These scores were compared with operative findings and the sensitivities were evaluated by McNemar test. Inter-observer agreements and the correlation with symptoms laterality were assessed with kappa statistics. The 3D T2W TSE and 2D TSE-SPACE had similar sensitivity in detecting foraminal stenosis (78.9% versus 78.9% in 32 foramen levels), spinal stenosis (100% versus 100% in 42 spinal levels), and nerve compression (92.9% versus 81.8% in 59 spinal nerves). The inter-observer agreements (κ = 0.849 vs. 0.451 for foraminal stenosis, κ = 0.809 vs. 0.503 for spinal stenosis, and κ = 0.681 vs. 0.429 for nerve compression) and symptoms correlation (κ = 0.449 vs. κ = 0.242) were better in 3D TSE-SPACE compared to 2D TSE. 3D TSE-SPACE with oblique coronal MPR images demonstrated better inter-observer agreements compared to 3D TSE-SPACE without oblique coronal MPR images (κ = 0.930 vs. κ = 0.681). Isotropic 3D T2W TSE-SPACE at 3.0 T was comparable to 2D T2W TSE for detecting foraminal stenosis, central spinal stenosis, and nerve compression with better inter-observer agreements and symptom correlation. © The Foundation Acta Radiologica 2014 Reprints and

  6. Safety aspects of using Ag-In-Cd absorber made by PT. Batan Teknologi (Persero) in the core of multi purposes reactor G.A. Siwabessy

    International Nuclear Information System (INIS)

    Anggoro Septilarso; Zulkarnain; Heryudo Kusumo

    2011-01-01

    Safety Evaluation has been carried out for the using of Ag-In-Cd Absorber made by PT. Batan Teknologi (Persero) in the core of Multi Purposes Reactor G.A. Siwabessy (RSG-GAS). PT. Batan Teknologi (Persero) only licensed by NUKEM GmbH to produce Fuel Element and Control Element U-Al, U 3 O 8 -Al dan U 3 Si 2 -Al, and not including to produce Ag-In-Cd Absorber. But, BAPETEN evaluator think that the danger would be greater if RSG-GAS use the older absorber than use Ag-In-Cd Absorber made by PT. Batan Teknologi. For this purposes, BAPETEN set some requirements and acceptance criteria to be met by the absorber, that is cold test, hot test, shutdown margin value, control rod drop test and visual test. The test show that Ag-In-Cd Absorber meets all the requirements and acceptance criteria required by BAPETEN. (author)

  7. Highlights of NES results from the TTE campaign at JET. The U- and M-FUND collaboration

    International Nuclear Information System (INIS)

    Henriksson, Hans

    2004-02-01

    The first experimental campaign with tritium in a thermonuclear fusion facility in six years was conducted at JET in the autumn of 2003. The trace tritium experimental (TTE) campaign produced DT-fusion with levels of over 0.2 MW. The neutron rate reached over 10 17 14-MeV DT-neutrons per second at periods with injection of tritium neutral beam (NB) power and during tritium gas puffs, as well as during periods of heating with electromagnetic waves in the radio frequency (RF) range. The results presented here were obtained from data collected with the magnetic proton recoil (MPR) neutron spectrometer together with other neutron data in connection with the MPR during TTE. A new method of calculating the absolute 14-MeV neutron yield using data from the MPR has been demonstrated, and data were analysed routinely during the campaign. An attempt to obtain an absolute value of the tritium concentration from neutron yield measurements was assessed and results are shown for a number of pulses heated with deuterium NB heating and with additional injection of tritium gas. Spectral analysis of MPR data both concerning RF and NB heated JET pulses have shown interesting results. A special study on the level of tritium retained in the walls after the TTE campaign has also been performed

  8. Progress of Indonesia RERTR related programs

    International Nuclear Information System (INIS)

    Soentono, S.; Arbie, B.; Surpto, A.

    2004-01-01

    In Indonesia, there are two main activities covering study, research ad development which can be related to reduced enrichment for research and test reactors (RERTR) program. The first activity is the attempt to improve the G.A. Siwabessy multi-purpose reactor (RSG-GAS) performance following the successful RERTR program on the development of low-enriched uranium (LEU) with high uranium loading density. This activity consists of manufacturing technology development and fabrication of LEU fuel in the form Of U 3 Si 2 -Al with high U loading density being capable to reach high burn-up, study oil the core conversion of the RSG- GAS from using oxide LEU fuel with loading density of ∼3 gU/cc into using LEU silicide fuel of higher U loading density to improve the in-core fuel management, the fuel utilization, and the cycle length, while keeping the neutron flux in the irradiation facilities remaining satisfactory and the power of the reactor remaining the same without resulting any serious penalty on the reactor safety. The second RERTR related activity is the attempt to use LEU, instead of HEU, as the target or fission product 99 Mo production to supply 99 mTc for medical purposes. This second activity is expected to consist of experiments covering irradiation of various forms of LEU targets in the RSG-GAS, dissolution processes of the irradiated targets, separation and purification processes to meet the radiopharmaceutical requirements and recovery of 235 U from the waste as well as treatment of the emerged wastes. (author)

  9. Development of Multipurpose PLC trainer for the simulator of reactor safety system

    International Nuclear Information System (INIS)

    Syaiful Bakhri; Deswandri; Ahmad Abtokhi

    2014-01-01

    PLC becomes one of the essential components for the current type of reactor which based on digital instrumentation and control. Several studies have demonstrated the promising results including the implementation of PLC's for RSG-GAS research reactor. However, research for the safety and reliability analysis can not be carried out freely in the existing systems.Therefore, this research aims to develop a PLC trainer employing micro PLC OMRON CP1MA which can be useful for simulator of various topics in reactor safety. Two experimental tests were carried out to show the PLC’s performances. The first experimental testing implementing reactor protection system of research reactor RSG-GAS shows the capacity of PLC system to identify the initiator of the SCRAM logic as well as giving a promptly response. Secondly, the application of PLC to controls the water level in dual reservoir system simulation, demonstrates the simplicity of the operation and design while maintaining the best performances. (author)

  10. Landfill Gas Energy Cost Model Version 3.0 (LFGcost-Web V3 ...

    Science.gov (United States)

    To help stakeholders estimate the costs of a landfill gas (LFG) energy project, in 2002, LMOP developed a cost tool (LFGcost). Since then, LMOP has routinely updated the tool to reflect changes in the LFG energy industry. Initially the model was designed for EPA to assist landfills in evaluating the economic and financial feasibility of LFG energy project development. In 2014, LMOP developed a public version of the model, LFGcost-Web (Version 3.0), to allow landfill and industry stakeholders to evaluate project feasibility on their own. LFGcost-Web can analyze costs for 12 energy recovery project types. These project costs can be estimated with or without the costs of a gas collection and control system (GCCS). The EPA used select equations from LFGcost-Web to estimate costs of the regulatory options in the 2015 proposed revisions to the MSW Landfills Standards of Performance (also known as New Source Performance Standards) and the Emission Guidelines (herein thereafter referred to collectively as the Landfill Rules). More specifically, equations derived from LFGcost-Web were applied to each landfill expected to be impacted by the Landfill Rules to estimate annualized installed capital costs and annual O&M costs of a gas collection and control system. In addition, after applying the LFGcost-Web equations to the list of landfills expected to require a GCCS in year 2025 as a result of the proposed Landfill Rules, the regulatory analysis evaluated whether electr

  11. 30 CFR 206.152 - Valuation standards-unprocessed gas.

    Science.gov (United States)

    2010-07-01

    ... to monitoring, review, and audit. For purposes of this section, gas which is sold or otherwise...'s value. (iv) How to value over-delivered volumes under a cash-out program. This paragraph applies to situations where a pipeline purchases gas from a lessee according to a cash-out program under a...

  12. Genetic and phenotypic variance and covariance components for methane emission and postweaning traits in Angus cattle.

    Science.gov (United States)

    Donoghue, K A; Bird-Gardiner, T; Arthur, P F; Herd, R M; Hegarty, R F

    2016-04-01

    Ruminants contribute 80% of the global livestock greenhouse gas (GHG) emissions mainly through the production of methane, a byproduct of enteric microbial fermentation primarily in the rumen. Hence, reducing enteric methane production is essential in any GHG emissions reduction strategy in livestock. Data on 1,046 young bulls and heifers from 2 performance-recording research herds of Angus cattle were analyzed to provide genetic and phenotypic variance and covariance estimates for methane emissions and production traits and to examine the interrelationships among these traits. The cattle were fed a roughage diet at 1.2 times their estimated maintenance energy requirements and measured for methane production rate (MPR) in open circuit respiration chambers for 48 h. Traits studied included DMI during the methane measurement period, MPR, and methane yield (MY; MPR/DMI), with means of 6.1 kg/d (SD 1.3), 132 g/d (SD 25), and 22.0 g/kg (SD 2.3) DMI, respectively. Four forms of residual methane production (RMP), which is a measure of actual minus predicted MPR, were evaluated. For the first 3 forms, predicted MPR was calculated using published equations. For the fourth (RMP), predicted MPR was obtained by regression of MPR on DMI. Growth and body composition traits evaluated were birth weight (BWT), weaning weight (WWT), yearling weight (YWT), final weight (FWT), and ultrasound measures of eye muscle area, rump fat depth, rib fat depth, and intramuscular fat. Heritability estimates were moderate for MPR (0.27 [SE 0.07]), MY (0.22 [SE 0.06]), and the RMP traits (0.19 [SE 0.06] for each), indicating that genetic improvement to reduce methane emissions is possible. The RMP traits and MY were strongly genetically correlated with each other (0.99 ± 0.01). The genetic correlation of MPR with MY as well as with the RMP traits was moderate (0.32 to 0.63). The genetic correlation between MPR and the growth traits (except BWT) was strong (0.79 to 0.86). These results indicate that

  13. Eighth meeting of the International Working Group on Gas-Cooled Reactors Vienna, 30 January - 1 February 1989. Summary report. Part 2

    International Nuclear Information System (INIS)

    1989-12-01

    The Eighth Meeting of the IAEA International Working Group on Gas-Cooled Reactors was held in Vienna, Austria, from 30 January - 1 February, 1989. The Summary Report (Part II) contains the papers which review the national programmes in the field of Gas-Cooled Reactors and other presentations at the Meeting. Refs, figs and tabs

  14. Motor of Lift RSG-GAS Performance Analysis after Repair

    International Nuclear Information System (INIS)

    Asep-Saepuloh; Yayan-Andriyanto; Yuyut-Suraniyanto

    2006-01-01

    The out of order an equipment is ordinary natural process happened, above all the equipment be used continually with very old time, as for as out of order can be resulted from kinds of cause. Lift motor out of order can be result by motor is broken or happened the body shorten then affected do not function it the lift, so until done rewinding process. The rewinding is furl to repeat at motor coils. Motor of Lift represent main activator machine turning around shares pulley. Lift Motor will work if there is called in normal operation condition or the moment manual switch if done maintenance. Motor used at lift is motor three phases with two speeds that is low speed and high speed. Rewinding process must be done removed the motor from Lift machine and have to be done by professional workshop. In during function test take place, temperature at coil reach 70 o C (exceeding boundary permitted). After done installation addition thermal at motor coil hence his temperature become normal that is only reach 50 o C. (author)

  15. Effects of caffeinated chewing gum on muscle pain during submaximal isometric exercise in individuals with fibromyalgia.

    Science.gov (United States)

    Umeda, Masataka; Kempka, Laura; Weatherby, Amy; Greenlee, Brennan; Mansion, Kimberly

    2016-04-01

    Physical activity is important to manage symptom of fibromyalgia (FM); however, individuals with FM typically experience augmented muscle pain during exercise. This study examined the effects of caffeinated chewing gum on exercise-induced muscle pain in individuals with FM. This study was conducted with a double-blind, placebo-controlled, cross-over design. Twenty-three patients with FM completed a caffeine condition where they consumed a caffeinated chewing gum that contains 100mg of caffeine, and a placebo condition where they consumed a non-caffeinated chewing gum. They completed isometric handgrip exercise at 25% of their maximal strength for 3 min, and muscle pain rating (MPR) was recorded every 30s during exercise. Clinical pain severity was assessed in each condition using a pain questionnaire. The order of the two conditions was randomly determined. MPR increased during exercise, but caffeinated chewing gum did not attenuate the increase in MPR compared to placebo gum. Clinical pain severity was generally associated with the average MPR and the caffeine effects on MPR, calculated as difference in the average MPR between the two conditions. The results suggest that more symptomatic individuals with FM may experience greater exercise-induced muscle pain, but benefit more from caffeinated chewing gum to reduce exercise-induced muscle pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. xCOLD GASS: The Complete IRAM 30 m Legacy Survey of Molecular Gas for Galaxy Evolution Studies

    Science.gov (United States)

    Saintonge, Amélie; Catinella, Barbara; Tacconi, Linda J.; Kauffmann, Guinevere; Genzel, Reinhard; Cortese, Luca; Davé, Romeel; Fletcher, Thomas J.; Graciá-Carpio, Javier; Kramer, Carsten; Heckman, Timothy M.; Janowiecki, Steven; Lutz, Katharina; Rosario, David; Schiminovich, David; Schuster, Karl; Wang, Jing; Wuyts, Stijn; Borthakur, Sanchayeeta; Lamperti, Isabella; Roberts-Borsani, Guido W.

    2017-12-01

    We introduce xCOLD GASS, a legacy survey providing a census of molecular gas in the local universe. Building on the original COLD GASS survey, we present here the full sample of 532 galaxies with CO (1–0) measurements from the IRAM 30 m telescope. The sample is mass-selected in the redshift interval 0.01 {10}9 {M}ȯ . The CO (1–0) flux measurements are complemented by observations of the CO (2–1) line with both the IRAM 30 m and APEX telescopes, H I observations from Arecibo, and photometry from SDSS, WISE, and GALEX. Combining the IRAM and APEX data, we find that the ratio of CO (2–1) to CO (1–0) luminosity for integrated measurements is {r}21=0.79+/- 0.03, with no systematic variations across the sample. The CO (1–0) luminosity function is constructed and best fit with a Schechter function with parameters {L}{CO}* =(7.77+/- 2.11)× {10}9 {{K}} {km} {{{s}}}-1 {{pc}}2, {φ }* =(9.84+/- 5.41)× {10}-4 {{Mpc}}-3, and α =-1.19+/- 0.05. With the sample now complete down to stellar masses of 109 {M}ȯ , we are able to extend our study of gas scaling relations and confirm that both molecular gas fractions ({f}{{{H}}2}) and depletion timescale ({t}{dep}({{{H}}}2)) vary with specific star formation rate (or offset from the star formation main sequence) much more strongly than they depend on stellar mass. Comparing the xCOLD GASS results with outputs from hydrodynamic and semianalytic models, we highlight the constraining power of cold gas scaling relations on models of galaxy formation.

  17. Status report of Indonesian research reactors

    International Nuclear Information System (INIS)

    Arbie, B.; Supadi, S.

    1995-01-01

    A general description of the three Indonesia research reactors, their irradiation facilities and future prospect are given. The 250 kW Triga Mark II in Bandung has been in operation since 1965 and in 1972 its designed power was increased to 1000 kW. The core grid from the previous 250 kW Triga Mark II was then used by Batan for designing and constructing the Kartini reactor in Yogyakarta. This reactor commenced its operation in 1979. Both Triga reactors have served a wide spectrum of utilization such as for manpower training in nuclear engineering, radiochemistry, isotope production, and beam research in solid state physics. The Triga reactor management in Bandung has a strong cooperation with the Bandung Institute of Technology and the one in Yogyakarta with the Gadjah Mada University which has a Nuclear Engineering Department at its Faculty of Engineering. In 1976 there emerged an idea to have a high flux reactor appropriate for Indonesia's intention to prepare an infrastructure for both nuclear energy and non-energy industry era. Such an idea was then realized with the achievement of the first criticality of the RSG-GAS reactor at the Serpong area. It is now expected that by early 1992 the reactor will reach its full 30 MW power level and by the end of 1992 the irradiation facilities be utilizable fully for future scientific and engineering work. As a part of the national LEU fuel development program a study has been underway since early 1989 to convert the RSG-GAS reactor core from using oxide fuel to using higher loading silicide fuel. (author)

  18. Design report on the guide box-reactivity and safety control plates for MPR reactor under normal operation conditions

    International Nuclear Information System (INIS)

    Markiewicz, M.

    1999-01-01

    The reactivity control system for the MPR reactor (Multi Purpose Reactor) is a critical component regarding safety, it must ensure a fast shut down, maintaining the reactor in subcritical condition under normal or accidental operation condition. For this purpose, this core component must be designed to maintain its operating capacity during all the residence time and under any foreseen operation condition. The mechanical design of control plates and guide boxes must comply with structural integrity, maintaining its geometric and dimensional stability within the pre-established limits to prevent interferences with other core components. For this, the heat generation effect, mechanical loads and environment and irradiation effects were evaluated during the mechanical design. The reactivity control system is composed of guide boxes, manufactured from Aluminium alloy, located between the fuel elements, and control absorber plates of Ag-In-Cd alloy hermetically enclosed by a cladding of stainless steel sliding inside de guide boxes. The upward-downward movement is transmitted by a rod from the motion device located at the reactor lower part. The design requirements, criteria and limits were established to fulfill with the normal and abnormal operation conditions. The design verifications were performed by analytical method, estimating the guide box and control plates residence time. The result of the analysis performed, shows that the design of the reactivity control system and the material selected, are appropriate to fulfill the functional requirements, with no failures attributed to the mechanical design. (author)

  19. Analyzing the Impacts of Increased Wind Power on Generation Revenue Sufficiency: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qin; Wu, Hongyu; Tan, Jin; Hodge, Bri-Mathias; Li, Wanning; Luo, Cheng

    2016-08-01

    The Revenue Sufficiency Guarantee (RSG), as part of make-whole (or uplift) payments in electricity markets, is designed to recover the generation resources' offer-based production costs that are not otherwise covered by their market revenues. Increased penetrations of wind power will bring significant impacts to the RSG payments in the markets. However, literature related to this topic is sparse. This paper first reviews the industrial practices of implementing RSG in major U.S. independent system operators (ISOs) and regional transmission operators (RTOs) and then develops a general RSG calculation method. Finally, an 18-bus test system is adopted to demonstrate the impacts of increased wind power on RSG payments.

  20. KETAHANAN KOROSI PADUAN Al-Mg 5052 DI DALAM AIR PENDINGIN NETRAL MENGANDUNG KLORIDA

    Directory of Open Access Journals (Sweden)

    Dicky Tri Jatmiko

    2015-07-01

    Full Text Available KETAHANAN KOROSI PADUAN Al-Mg 5052 DI DALAM AIR PENDINGIN NETRAL MENGANDUNG KLORIDA. Paduan Al-Mg 5052 adalah material yang biasa digunakan untuk kelongsong elemen bakar nuklir karena serapan fluks netronnya rendah dan tahan korosi di dalam air demineralisasi pada kondisi operasi reaktor. Makalah ini difokuskan untuk mengetahui ketahanan korosi paduan Al-Mg 5052 di dalam air dengan pH netral dan mengandung klorida sebagai pengganti air demineralisasi pendingin primer Reaktor Serba Guna GA Siwabessy (RSG-GAS. Penelitian mencakup pengukuran laju korosi menggunakan metode Tafel, prediksi mekanisme korosi menggunakan metode voltametri siklik dan analisa produk korosi dengan metode difraksi sinar X. Percobaan dilakukan dengan variasi temperatur 30°C, 35°C, 40°C, dan 45°C, serta variasi konsentrasi larutan natrium  klorida 0,05 M, 0,25 M, dan 0,5 M. Hasil penelitian ini menunjukkan bahwa paduan Al-Mg 5052 terkorosi dengan kategori “dapat diabaikan” hingga “sedang” dalam larutan natrium klorida menjadi produk yang larut dalam air pada satu tahap reaksi oksidasi irreversible.   CORROSION RESISTANCE OF Al-Mg ALLOY 5052 IN CHLORIDE CONTAINING NEUTRAL COOLING WATER. Al-Mg alloy 5052 is a material used as nuclear fuel element cladding due to its low neutron flux absorption and high corrosion resistance in demineralized water. This research is focused to know of the corrosion resistance of Al-Mg alloy 5052 in chloride containing neutral water used as demineralized primary cooling water substitute in GA Siwabessy Multi Purpose Reactor (RSG-GAS. This research covers the corrosion rate measurement using the Tafel method, corrosion process prediction using cyclic voltammetry method and corrosion product analysis using X-Ray Diffraction method. The experiments are carried out at temperature variation of 30°C, 35°C, 40°C and 45°C, as well as sodium chloride concentration of 0.05 M, 0.25 M and 0.5 M. The research results show that Al-Mg alloy 5052

  1. Eighth meeting of the International Working Group on Gas-Cooled Reactors, Vienna, 30 January - 1 February 1989. Summary report. Part 1

    International Nuclear Information System (INIS)

    1989-12-01

    The Eighth Meeting of the IAEA International Working Group on Gas-Cooled Reactors was held in Vienna, Austria, from 30 January - 1 February, 1989. The Summary Report (Part I) contains the Minutes of the Meeting

  2. Changes in endotoxin levels in T2DM subjects on anti-diabetic therapies

    Directory of Open Access Journals (Sweden)

    Kumar Sudhesh

    2009-04-01

    Full Text Available Abstract Introduction Chronic low-grade inflammation is a significant factor in the development of obesity associated diabetes. This is supported by recent studies suggesting endotoxin, derived from gut flora, may be key to the development of inflammation by stimulating the secretion of an adverse cytokine profile from adipose tissue. Aims The study investigated the relationship between endotoxin and various metabolic parameters of diabetic patients to determine if anti-diabetic therapies exerted a significant effect on endotoxin levels and adipocytokine profiles. Methods Fasting blood samples were collected from consenting Saudi Arabian patients (BMI: 30.2 ± (SD5.6 kg/m2, n = 413, consisting of non-diabetics (ND: n = 67 and T2DM subjects (n = 346. The diabetics were divided into 5 subgroups based on their 1 year treatment regimes: diet-controlled (n = 36, metformin (n = 141, rosiglitazone (RSG: n = 22, a combined fixed dose of metformin/rosiglitazone (met/RSG n = 100 and insulin (n = 47. Lipid profiles, fasting plasma glucose, insulin, adiponectin, resistin, TNF-α, leptin, C-reactive protein (CRP and endotoxin concentrations were determined. Results Regression analyses revealed significant correlations between endotoxin levels and triglycerides (R2 = 0.42; p 2 = 0.10; p 2 = 0.076; p 2 = 0.032; p 2 = 0.055; p Conclusion We conclude that sub-clinical inflammation in T2DM may, in part, be mediated by circulating endotoxin. Furthermore, that whilst the endotoxin and adipocytokine profiles of diabetic patients treated with different therapies were comparable, the RSG group demonstrated significant differences in both adiponectin and endotoxin levels. We confirm an association between endotoxin and serum insulin and triglycerides and an inverse relationship with HDL. Lower endotoxin and higher adiponectin in the groups treated with RSG may be related and indicate another mechanism for the effect of RSG on insulin sensitivity.

  3. Design of magnetic analysis system for magnetic proton recoil spectrometer

    International Nuclear Information System (INIS)

    Qi Jianmin; Jiang Shilun; Zhou Lin; Peng Taiping

    2010-01-01

    Magnetic proton recoil (MPR) spectrometer is a novel diagnostic instrument with high performance for measurements of the neutron spectra from inertial confinement fusion (ICF) experiments and high power fusion devices. The design of the magnetic analysis system, which is a key part of the compact MPR-type spectrometer, has been completed through two-dimensional beam transport simulations and three-dimensional particle transport simulation. The analysis of the system's parameters and performances was performed, as well as system designs based on preferential principles of energy resolution, detection efficiency, and count rate, respectively. The results indicate that the magnetic analysis system can achieve a detection efficiency of 10 -5 ∼ 10 -4 level at the resolution range of 1.5% to 3.0% and fulfill the design goals of the compact MPR spectrometer. (authors)

  4. The evaluation of accuracy of NAA method used by P2TRR laboratory with food standard reference material analysis

    International Nuclear Information System (INIS)

    Rina M, Th.; Sri-Wardhani; Sunarko

    2003-01-01

    The NAA method is the analysis method with high precision and accuracy level. The precision and accuracy of NAA laboratory in P2TRR had been evaluated with SRM 1573a Tomato Leaf and CRM No.9 Sargasso. Samples were irradiated in RSG-GAS's rabbit system and counted with gamma spectrometry. The results obtained from this research are for the SRM 1573a sample the test could analyze 17 elements of the 40 certified elements, and for CRM No.9 sample the test could analyze 16 elements of the 30 certified elements. The result of quantitative analysis indicate the different deviation of each element between 2 -10.5 % compared to the certificate data. This deviation value <15%, this value shows that the precision and accuracy level is good enough

  5. The evaluation of accuracy of NAA method used by P2TRR laboratory with food standard reference material analysis; Evaluasi akurasi lab. AAN P2TRR dengan analisis cuplikan standar acuan bahan makanan

    Energy Technology Data Exchange (ETDEWEB)

    Rina M, Th; Sri-Wardhani,; Sunarko, [Center for Development of Research Reactor Technology (Indonesia)

    2003-05-15

    The NAA method is the analysis method with high precision and accuracy level. The precision and accuracy of NAA laboratory in P2TRR had been evaluated with SRM 1573a Tomato Leaf and CRM No.9 Sargasso. Samples were irradiated in RSG-GAS's rabbit system and counted with gamma spectrometry. The results obtained from this research are for the SRM 1573a sample the test could analyze 17 elements of the 40 certified elements, and for CRM No.9 sample the test could analyze 16 elements of the 30 certified elements. The result of quantitative analysis indicate the different deviation of each element between 2 -10.5 % compared to the certificate data. This deviation value <15%, this value shows that the precision and accuracy level is good enough.

  6. The prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint in patients with mandibular prognathism without internal derangement. MR and helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takafumi; Ito, Jusuke; Tanaka, Rei; Koyama, Jun-ichi; Kobayashi, Fukiko [Niigata Univ. (Japan). Graduate School of Medical and Dental Sciences

    2002-06-01

    The aim of this study was to assess the prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint without internal derangement. Sixty joints of 30 consecutive patients with mandibular prognathism were evaluated with both MR imaging and helical CT. On MPR images obtained with helical CT, erosive osseous changes of the articular eminence were observed in 18 joints (30%) of 13 patients. None of the joints studied demonstrated an osseous change in the mandibular condyle. MR imaging failed to detect erosive osseous changes of the articular eminence in all of the joints studied. In conclusion, MPR images obtained with helical CT were of value to detect erosive osseous changes of the articular eminence. (author)

  7. The prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint in patients with mandibular prognathism without internal derangement. MR and helical CT findings

    International Nuclear Information System (INIS)

    Hayashi, Takafumi; Ito, Jusuke; Tanaka, Rei; Koyama, Jun-ichi; Kobayashi, Fukiko

    2002-01-01

    The aim of this study was to assess the prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint without internal derangement. Sixty joints of 30 consecutive patients with mandibular prognathism were evaluated with both MR imaging and helical CT. On MPR images obtained with helical CT, erosive osseous changes of the articular eminence were observed in 18 joints (30%) of 13 patients. None of the joints studied demonstrated an osseous change in the mandibular condyle. MR imaging failed to detect erosive osseous changes of the articular eminence in all of the joints studied. In conclusion, MPR images obtained with helical CT were of value to detect erosive osseous changes of the articular eminence. (author)

  8. Development Output Program Data Entry System For RSG-GAS Application

    International Nuclear Information System (INIS)

    Sihombing, Edison; Sitorus, Jupiter; Imron, M.; Azriani

    2000-01-01

    Data Entry System is a data acquisition software of failure data of system and component. The acquisition data was calculated to get the failure rate, upper bound value. Since the calculated is big enough the development on Data Entry System program was introduced. Now, the data Entry System can be run to calculate big enough data

  9. Neutronic design of the RSG-GAS compact core without CIP

    International Nuclear Information System (INIS)

    Susilo, Jati; Kuntoro, Iman

    2002-01-01

    Improvement of the efficiency of reactor operation can be chivvied by some ways, such as, the uranium density of the fuel, loading pattern and configuration of core elements. The paper deals with determination of optimal configuration of the compact core with out CIP. Calculations were carried out by means of SRAC-PIJ module for cross section generation and SRAC-ASMBURN for core calculations. The optimal compact core obtained, showed that no-CIP compact core increase highest reactivity value about 0,84 % Δk/k and longest time operation about 1,19 time in the safety criteria that is power peaking factor less then 1,4 and margin control element worth less then volume in the first design that -2,2% Δk/k

  10. Neutronic design of the RSG-GAS compact core without CIP

    International Nuclear Information System (INIS)

    Jati-Susilo; Iman-Kuntoro

    2003-01-01

    Improvement of the efficiency of reactor operation can be achieved by some ways, such as, the uranium density of the fuel, loading pattern and configuration of core elements. The paper deals with determination of optimal configuration of the compact core with out CIP. Calculations were carried out by means of SRAC-PIJ module for cross section generation and SRAC-ASMBURN for core calculations. The optimal compact core obtained, showed that no-CIP compact core increase highest reactivity value about 1.06 % Δk/k and longest time operation about 1.19 time in the safety criteria that is power peaking factor less then 1.4 and margin control element worth less then value in the first design that -2.2% Δk/k

  11. Assessment of heat loss for RSG-GAS primary cooling system

    International Nuclear Information System (INIS)

    Dibyo, S.

    1998-01-01

    Heat Loss is part term of energy balance equation of system, therefore heat loss very important thing in the thermal dynamic analysis. Heat energy loosed from the surface pipe to the air in the room was calculated. Heat energy pass through by conduction, convection and radiation. The convection process are caused by moving of air density, i.e up flow of the hot air return to be down flow. The heat transfer phenomenon could be determined by empirical correlation of Heilman. The primary cooling system is consisted to the 3 zone : 1). Zone of (safety valves-heat exchanger), 2). Zone of heat exchanger surfaces, 3). Zone of heat exchanger-reactor pool. By using input data of air temperature are about 25 o C, temperature of primary coolant about 45 o C, The heat Loss along the pipes to the air are 23.9 k watt or 0.1%

  12. Analysis for RSG-GAS operational characteristics of reactor cooling system

    International Nuclear Information System (INIS)

    Nurhappy, T.

    1998-01-01

    Analysis of operational characteristics of reactor cooling systems (JE01 and PA) is aimed at determining the effects of operation and maintenance patterns to the operational characteristic of the system. Analysis is carried out by virtue of the operating and maintenance data from 1987 to 1997, comprising the operating hours (duration) and data on operating failures of the systems. Results of study show that, either separately or jointly, the operating and maintenance patterns will qualitatively affect the operational characteristic of the systems

  13. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  14. Consistency of policy instruments. How the EU could move to a -30% greenhouse gas reduction target

    Energy Technology Data Exchange (ETDEWEB)

    Hoehne, N.; Hagemann, M.; Moltmann, S.; Escalante, D. [Ecofys Germany, Berlin (Germany)

    2011-04-15

    The report provides options for how to achieve a 30% reduction in greenhouse gas emissions, in the EU, from 1990 to 2020. The EU has agreed a set of goals (objectives) and related instruments for 2020. The most significant objectives are the 20% or 30% reduction of greenhouse gases (all emissions, both within and outside the Emissions Trading System), the 20% improvement of energy efficiency and the 20% of renewable energy use by 2020. The stringency of the instruments used to reach these goals, must be set carefully to ensure overall consistency. Particularly after the economic crisis of 2008/2009, the Climate and Energy Package has to be 'tuned' again to be fully consistent, e.g. fast take up of renewable energy and fewer emissions due to the recession may cause an over-allocation in the EU-ETS.

  15. The study of the installation of spent fuel interim storage facility from safety aspect point of view

    International Nuclear Information System (INIS)

    Djunaidi, Prayogo S.

    1999-01-01

    The installation of the ISFSF of the RSG-GAS has been come a cureneed, since the RSG-GAS has been operating for more than 10 years. The spent fuel stored in the reactor storage pool in creasing from time to time and therefore a long time storage is needed until the decommissioning of the reactor. The safety aspect related to the installation of the ISFSF has been studied, but the most important aspect are prevention of criticality of the spen fuel in the storage. The radiation dose must be less than that has been recommended by ICRP and the release of the radioactive material must be avoided . In this paper one of the safety aspects i.e. the radiological aspect is described, while the other aspects are referenced to safety analysis report of the facility. From the calculation it can be seen that in accident condition the total radiation dose received by the handling operator is 1.06 mSv and 1.6 mSv resulted from Kr-85 and 1-131. This is lower than the limitation recommended by the ICRP No. 60.1990. Verification for other safety aspect of the facility in still needed

  16. Predictive maintenance technology development at G.A. Siwabessy multipurpose reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jupiter Sitorus Pane; Imron, M.; Sapto Hartoko; Sentot Alibasya Harahap [Multipurpose Research Reactor G.A. Siwabessy, National Nuclear Energy Agency (Indonesia)

    1999-10-01

    Safe operation of reactor is certainly influenced by condition of system and component equipped to the reactor's system. In order to maintain the condition of that systems and components, RSG-GAS has arranged maintenance program with time-basis. All 6 (six) groups of reactor systems are maintained within interval of weekly, monthly, three monthly, six-monthly, yearly, five-yearly appropriately. The experience showed that event though the maintenance was performed persistently, the condition of system and component are still not able to determine exactly. The possibility of accidental failure is open since the failure factor are varied and complicated. In order to limit an uncertainty of the component condition a based maintenance shall be introduced. An infrared investigation and manual vibration analysis had been used to diagnose the condition of some RSG-GAS' components. In addition, other alternative technology for predictive maintenance was developed. It is started by computerizing the database maintenance and doing historical review for its aging management, and developing data acquisition and processing equipment using Lab View computer program for collecting and processing signal data from dynamics system. This paper describes briefly the status of those development results. (author)

  17. Predictive maintenance technology development at G.A. Siwabessy multipurpose reactor

    International Nuclear Information System (INIS)

    Jupiter Sitorus Pane; Imron, M.; Sapto Hartoko; Sentot Alibasya Harahap

    1999-01-01

    Safe operation of reactor is certainly influenced by condition of system and component equipped to the reactor's system. In order to maintain the condition of that systems and components, RSG-GAS has arranged maintenance program with time-basis. All 6 (six) groups of reactor systems are maintained within interval of weekly, monthly, three monthly, six-monthly, yearly, five-yearly appropriately. The experience showed that event though the maintenance was performed persistently, the condition of system and component are still not able to determine exactly. The possibility of accidental failure is open since the failure factor are varied and complicated. In order to limit an uncertainty of the component condition a based maintenance shall be introduced. An infrared investigation and manual vibration analysis had been used to diagnose the condition of some RSG-GAS' components. In addition, other alternative technology for predictive maintenance was developed. It is started by computerizing the database maintenance and doing historical review for its aging management, and developing data acquisition and processing equipment using Lab View computer program for collecting and processing signal data from dynamics system. This paper describes briefly the status of those development results. (author)

  18. The development of a cryopump for stripper gas pumping in a 30 MV tandem Van de Graaff

    International Nuclear Information System (INIS)

    Halliday, B.S.

    1980-04-01

    The development of a cryopump is described for a 30 MV tandem Van de Graaf accelerator to control the vacuum pressure in the beam tube at the centre terminal when a gas stripper is in use. The system has been fully assembled and has been mechanically tested, the cryo pumps have been cooled to 18 0 K and the insulation tested electrically to +- 20 kV between the pump elements and the biased stripper canal. (UK)

  19. Development of new ORIGEN2 data library sets for research reactors with light water cooled oxide and silicide LEU (20 w/o) fuels based on JENDL-3.3 nuclear data

    International Nuclear Information System (INIS)

    Liem, Peng Hong; Sembiring, Tagor Malem

    2013-01-01

    Highlights: • We developed new ORIGEN2 data library sets for research reactors based on JENDL-3.3. • The sets cover oxide and silicide LEU fuels with meat density up to 4.74 g U/cm 3 . • Two kinds of data library sets are available: fuel region and non-fuel regions. • We verified the new data library sets with other codes. • We validated the new data library against a non-destructive test. -- Abstract: New sets of ORIGEN2 data library dedicated to research/testing reactors with light water cooled oxide and silicide LEU fuel plates based on JENDL-3.3 nuclear data were developed, verified and validated. The new sets are considered to be an extension of the most recent release of ORIGEN2.2UPJ code, i.e. the ORLIBJ33 library sets. The newly generated ORIGEN2 data library sets cover both oxide and silicide LEU fuels with fuel meat density range from 2.96 to 4.74 g U/cm 3 used in the present and future operation of the Indonesian 30 MWth RSG GAS research reactor. The new sets are expected applicable also for other research/testing reactors which utilize similar fuels or have similar neutron spectral indices. In addition to the traditional ORIGEN2 library sets for fuel depletion analyses in fuel regions, in the new data library sets, new ORIGEN2 library sets for irradiation/activation analyses were also prepared which cover all representative non-fuel regions of RSG GAS such as reflector elements, irradiation facilities, etc. whose neutron spectra are significantly softer than fuel regions. Verification with other codes as well as validation with a non-destructive test result showed promising results where a good agreement was confirmed

  20. The management of spent resins at rad waste installation (RWI)

    International Nuclear Information System (INIS)

    Johan, Bahdir

    2002-01-01

    During years 2000 RWI has been managed 1.596 liters the spent resins from MPR, multipurpose reactor G.A. Siwabessy (RSG-GAS). The spent resins containing 6 0 C o, 1 37 C s and 8 9 S r. The immobilization of spent resins using Portland cement type I and sand in shell 950 liter has been carried out. The immobilization product quality was characterized by measurement of surface exposure, density, compression strength and leaching rate. The samples each being 3000 g are made by taking cement slurry from the 950 liter shell. The samples are molded in the form of cylinder of 50 mm diameter and height 50 mm. The density was determined by weighing and measuring sample's volume. The compression strength was determinate using P aul Weber a pparatus. The leaching rate by immerse of the samples in the demineralized water and the rate the contact surface dose measures using survey meter. The results show that the density ρ= (1,72 ± 0,01) s/d 1,73 ± 0,03) g.cm - 3 , the compression strength Γ= (20,10 ± 0,02 s/d 20,18 ± 0,02) N.mm - 2 , the leaching rate R n = (1,32x10 - 2 s /d 2,0x10 - 3 ) g.cm - 2 . h - 1 , the contact surface rate D 0 = (0,374 s/d 0,79) mrem.jam - 1 a nd 1m distance from the surface D 1 = (0,18 s/d 0,19) mrem.jam - 1 h ave been in compliance with the criteria recommended by IAEA the quality of spent resins concrete in shell 950 liters (number 22C to 27C) is qualified for ultimate disposal

  1. Kinesio taping and manual pressure release: Short-term effects in subjects with myofasical trigger point.

    Science.gov (United States)

    Chao, Yu Wen; Lin, Jiu Jenq; Yang, Jing Lan; Wang, Wendy Tzyy-Jiuan

    2016-01-01

    Randomized controlled trial. Myofascial pain syndrome is characterized by myofascial trigger points (MTrPs) and fascia tenderness. We investigated the effects of manual pressure release (MPR) alone or in combination with taping (MPR/MKT) in subjects with MTrPs. Fifteen and 16 subjects received MPR and MPR/MKT respectively. Outcomes including Pressure pain threshold, muscle stiffness, mechanomyography were assessed at baseline, post-intervention and 7-days later. Pressure pain threshold improved significantly (d = 1.79, p < 0.005) in both groups. Significant improvement in muscle stiffness in the MPR/MKT group (0.27-0.49 mm) as compared to the MPR group (-0.02-0.23 mm). Mechanomyography amplitude in the MPR/MKT group was significantly higher than that of the MPR group (p < 0.05). MPR and MPR/MKT are effective in reducing pain in these subjects. MPR/MKT has a greater effect on muscle stiffness and contraction amplitude. IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  2. RED SUPERGIANTS AS COSMIC ABUNDANCE PROBES: THE FIRST DIRECT METALLICITY DETERMINATION OF NGC 4038 IN THE ANTENNAE

    International Nuclear Information System (INIS)

    Lardo, C.; Davies, B.; Kudritzki, R-P.; Gazak, J. Z.; Evans, C. J.; Patrick, L. R.; Bergemann, M.; Plez, B.

    2015-01-01

    We present a direct determination of the stellar metallicity in the close pair galaxy NGC 4038 (D = 20 Mpc) based on the quantitative analysis of moderate-resolution KMOS/Very Large Telescope spectra of three super star clusters. The method adopted in our analysis has been developed and optimized to measure accurate metallicities from atomic lines in the J-band of single red supergiant (RSG) or RSG-dominated star clusters. Hence, our metallicity measurements are not affected by the biases and poorly understood systematics inherent to strong line H ii methods, which are routinely applied to massive data sets of galaxies. We find [Z] = +0.07 ± 0.03 and compare our measurements to H ii strong line calibrations. Our abundances and literature data suggest the presence of a flat metallicity gradient, which can be explained as redistribution of metal-rich gas following the strong interaction

  3. The Effect of Rosiglitazone on Bone Quality in a Rat Model of Insulin Resistance and Osteoporosis

    Science.gov (United States)

    Sardone, Laura Donata

    Rosiglitazone (RSG) is an insulin-sensitizing drug used to treat Type 2 Diabetes Mellitus (T2DM). Clinical trials show that women taking RSG experience more limb fractures than patients taking other T2DM drugs. The purpose of this study is to understand how RSG (3mg/kg/day and 10mg/kg/day) and the bisphosphonate alendronate (0.7mg/kg/week) alter bone quality in the male, female and female ovariectomized (OVX) Zucker fatty rat model over a 12 week period. Bone quality was evaluated by mechanical testing of cortical and trabecular bone. Microarchitecture, bone mineral density (BMD), cortical bone porosity, bone formation/resorption and mineralization were also measured. Female OVX RSG10mg/kg rats had significantly lower vertebral BMD and compromised trabecular architecture versus OVX controls. Increased cortical porosity and decreased mechanical properties occurred in these rats. ALN treatment prevented these negative effects in the OVX RSG model. Evidence of reduced bone formation and excess bone resorption was detected in female RSG-treated rats.

  4. Landfill Gas Energy Cost Model Version 3.0 (LFGcost-Web V3.0)

    Science.gov (United States)

    To help stakeholders estimate the costs of a landfill gas (LFG) energy project, in 2002, LMOP developed a cost tool (LFGcost). Since then, LMOP has routinely updated the tool to reflect changes in the LFG energy industry. Initially the model was designed for EPA to assist landfil...

  5. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  6. The effects of 6-mercaptopurine nucleotide derivatives on the growth and survival of 6-mercaptopurine-sensitive and -resistant cell culture lines.

    Science.gov (United States)

    Johnston, H P; Hawley, P; White, S E; Gibson, I; Tidd, D M

    1985-04-01

    6-Mercaptopurine (MP)-sensitive and -resistant cell culture lines were used to further characterize the apparent ability of MP nucleotide derivatives to overcome resistance to the parent drug. 6-Mercaptopurine-9-beta-D-ribofuranoside 5'-monophosphate [MPRP], bis(6-mercaptopurine-9-beta-D-ribofuranoside)-5', 5"'-monophosphate [bis(MPR)P], bis(O2',O3'-dibutyryl-6-mercaptopurine-9-beta-D-ribofuranoside)-5', 5"'-monophosphate [bis(dibut.MPR)P], and O2',O3'-dibutyryl-6-mercaptopurine-9-beta-D-ribofuranoside 5'-monophosphate [dibut.MPRP] were tested for cytotoxic and/or growth inhibitory effects against MP-resistant sublines of V79 Chinese hamster lung fibroblasts (CH/TG) and L1210 mouse leukaemia cells (L1210/MPR) in which deficiencies of hypoxanthine-guanine phosphoribosyltransferase, and hence drug nucleotide forming capacity were the basis of resistance. L1210/MPR cells were totally resistant to 1 mM 6-mercaptopurine-9-beta-D-ribofuranoside [MPR] and 2 mM MPRP, but were inhibited by high concentrations (greater than 0.25 mM) of bis(MPR)P. These results suggested that bis(MPR)P was taken up by cells as the intact molecule since MPR and MPRP were its extracellular breakdown products. L1210/MPR cells were much more sensitive to the lipophilic bis(dibut.MPR)P derivative which had a predominantly cytotoxic action as judged by trypan blue staining and the ability of treated cells to produce macroscopic colonies in soft agar medium. However, cells killed by bis(dibut.MPR)P did not disintegrate appreciably over periods of up to 10 days. The effects of bis(dibut.MPR)P were probably the result of cellular uptake of the intact molecule. Dibut.MPRP showed minimal ability to inhibit L1210/MPR cells although this compound was a possible breakdown product of bis(dibut.MPR)P and a source of the same extracellular degradation products. The median cell size decreased in L1210/MPR cultures during exposure to both bis(MPR)P and bis(dibut.MPR)P. This effect was elicited more rapidly and

  7. The effects of 6-mercaptopurine nucleotide derivatives on the growth and survival of 6-mercaptopurine-sensitive and -resistant cell culture lines.

    Science.gov (United States)

    Johnston, H. P.; Hawley, P.; White, S. E.; Gibson, I.; Tidd, D. M.

    1985-01-01

    6-Mercaptopurine (MP)-sensitive and -resistant cell culture lines were used to further characterize the apparent ability of MP nucleotide derivatives to overcome resistance to the parent drug. 6-Mercaptopurine-9-beta-D-ribofuranoside 5'-monophosphate [MPRP], bis(6-mercaptopurine-9-beta-D-ribofuranoside)-5', 5"'-monophosphate [bis(MPR)P], bis(O2',O3'-dibutyryl-6-mercaptopurine-9-beta-D-ribofuranoside)-5', 5"'-monophosphate [bis(dibut.MPR)P], and O2',O3'-dibutyryl-6-mercaptopurine-9-beta-D-ribofuranoside 5'-monophosphate [dibut.MPRP] were tested for cytotoxic and/or growth inhibitory effects against MP-resistant sublines of V79 Chinese hamster lung fibroblasts (CH/TG) and L1210 mouse leukaemia cells (L1210/MPR) in which deficiencies of hypoxanthine-guanine phosphoribosyltransferase, and hence drug nucleotide forming capacity were the basis of resistance. L1210/MPR cells were totally resistant to 1 mM 6-mercaptopurine-9-beta-D-ribofuranoside [MPR] and 2 mM MPRP, but were inhibited by high concentrations (greater than 0.25 mM) of bis(MPR)P. These results suggested that bis(MPR)P was taken up by cells as the intact molecule since MPR and MPRP were its extracellular breakdown products. L1210/MPR cells were much more sensitive to the lipophilic bis(dibut.MPR)P derivative which had a predominantly cytotoxic action as judged by trypan blue staining and the ability of treated cells to produce macroscopic colonies in soft agar medium. However, cells killed by bis(dibut.MPR)P did not disintegrate appreciably over periods of up to 10 days. The effects of bis(dibut.MPR)P were probably the result of cellular uptake of the intact molecule. Dibut.MPRP showed minimal ability to inhibit L1210/MPR cells although this compound was a possible breakdown product of bis(dibut.MPR)P and a source of the same extracellular degradation products. The median cell size decreased in L1210/MPR cultures during exposure to both bis(MPR)P and bis(dibut.MPR)P. This effect was elicited more rapidly and

  8. Western Gas Sands Project. Status report, 1 September 1979-30 September 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-01-01

    This report summarizes progress of the government-sponsored projects directed toward increasing gas production from the low-permeability gas sands of the western United States. Bartlesville Energy Technology Center continued work on rock-fluid interaction and advanced logging techniques. Lawrence Livermore Laboratory continued experimental and theoretical work on hydraulic fracturing mechanics and analysis of well test data. Los Alamos Scientific Laboratory continued work on permeability and porosity determination of core samples and geological support studies. Sandia Laboratories continued work on their EGR Instrumentation and Diagnostic Program. Cyclic gas injection continued at Colorado Interstate Gas Company's Miller No. 1 and Sprague No. 1 wells. The DOE Well Test Facility is continuing to provide technical support to the Gas Research Institute/Rio Blanco Natural Gas MHF experiment. The Gas Producing Enterprises, Inc. Natural Buttes Unit wells continued to flow to sales. The Mitchell Energy Corporation Muse-Duke No. 1 was opened after a 28-day shut-in period. The hydraulic fracturing containment experiment continued for the Sandia-mineback program.

  9. Stress-induced grey matter loss determined by MRI is primarily due to loss of dendrites and their synapses.

    Science.gov (United States)

    Kassem, Mustafa S; Lagopoulos, Jim; Stait-Gardner, Tim; Price, William S; Chohan, Tariq W; Arnold, Jonathon C; Hatton, Sean N; Bennett, Maxwell R

    2013-04-01

    Stress, unaccompanied by signs of post-traumatic stress disorder, is known to decrease grey matter volume (GMV) in the anterior cingulate cortex (ACC) and hippocampus but not the amygdala in humans. We sought to determine if this was the case in stressed mice using high-resolution magnetic resonance imaging (MRI) and to identify the cellular constituents of the grey matter that quantitatively give rise to such changes. Stressed mice showed grey matter losses of 10 and 15 % in the ACC and hippocampus, respectively but not in the amygdala or the retrosplenial granular area (RSG). Concurrently, no changes in the number or volumes of the somas of neurons, astrocytes or oligodendrocytes were detected. A loss of synaptic spine density of up to 60 % occurred on different-order dendrites in the ACC and hippocampus (CA1) but not in the amygdala or RSG. The loss of spines was accompanied by decreases in cumulative dendritic length of neurons of over 40 % in the ACC and hippocampus (CA1) giving rise to decreases in volume of dendrites of 2.6 mm(3) for the former and 0.6 mm(3) for the latter, with no change in the amygdala or RSG. These values are similar to the MRI-determined loss of GMV following stress of 3.0 and 0.8 mm(3) in ACC and hippocampus, respectively, with no changes in the amygdala or RSG. This quantitative study is the first to relate GMV changes in the cortex measured with MRI to volume changes in cellular constituents of the grey matter.

  10. Technical and Physical Activities of Small-Sided Games in Young Korean Soccer Players.

    Science.gov (United States)

    Joo, Chang H; Hwang-Bo, Kwan; Jee, Haemi

    2016-08-01

    Joo, CH, Hwang-Bo, K, and Jee, H. Technical and physical activities of small-sided games in young Korean soccer players. J Strength Cond Res 30(8): 2164-2173, 2016-The aim of this study was to examine the technical aspects and physical demands during small-sided games (SSGs) with different sized pitches in young Korean soccer players. Participants were randomly selected during a nationally held youth competition. Three different game formats were used: SSG8 (8 vs. 8 played on a small-sized field [68 × 47 m]), RSG8 (8 vs. 8 played on a regular-sized field [75 × 47 m]), and RSG11 (11 vs. 11 played on a regular-sized field). Eleven technical (ball touches, passes, and shots) and 6 physical demand variables (exercise frequency by intensity) were observed and analyzed. Same variables were also analyzed for the goalkeepers. As a result, SSG8 and RSG8 showed significantly greater numbers of technical plays in 5 and 4 variables in comparison to RSG11, respectively. In addition, although the exercise intensities increased slightly in both SSG formats, the amount was within the similar range as previous reports. In conclusion, the SSGs with reduced number of players may be referred in young players to effectively train them in technical aspects of the game by allowing greater ball exposure time without excessive physical demands. Various confounding factors such as pitch dimension should be carefully considered for training specific technical and physical variables in young Korean players.

  11. The central object R 136 in the gas nebula 30 Doradus - Structure, color, mass and excitation parameter

    Science.gov (United States)

    Feitzinger, J. V.; Schlosser, W.; Schmidt-Kaler, T.; Winkler, C.

    1980-04-01

    Photographic observations with the 3,6 m ESO and 0,61 m Bochum telescopes in different colours of the central part of the 30 Doradus Nebula are presented. The structure of the central object R 136 is studied by image analysis methods, i.e. digitalisation and contrast enhancement. The central object R 136 of the supergiant gas nebula 30 Doradus consists of three components; the main component covers an area of (0.7 pc)2. The components show a colour gradient, R 136a being much bluer than R 136c. This composite structure is seen in photographic IR, U and V likewise. A plot of the spectral intensity distribution from λ = 73 cm to 1550 Å of the central 2'.5 × 2'.5 region of 30 Doradus is given. The main contribution in the UV can be attributed to R 136. This object dominates the of the central part of 30 Doradus. It determines together with 16 other bright stars in the center the excitation parameter of the nebula. Its effective temperature lies between 50000 and 55000K and the tipper and lower mass values are 250 and 103 solar masses. The bolometric magnitude is brighter than -l4m. The inner structure of 30 Doradus can be explained as the result of the stellar-wind of R 136.

  12. Electroacupuncture Reduces Weight Gain Induced by Rosiglitazone through PPARγ and Leptin Receptor in CNS

    Directory of Open Access Journals (Sweden)

    Xinyue Jing

    2016-01-01

    Full Text Available We investigate the effect of electroacupuncture (EA on protecting the weight gain side effect of rosiglitazone (RSG in type 2 diabetes mellitus (T2DM rats and its possible mechanism in central nervous system (CNS. Our study showed that RSG (5 mg/kg significantly increased the body weight and food intake of the T2DM rats. After six-week treatment with RSG combined with EA, body weight, food intake, and the ratio of IWAT to body weight decreased significantly, whereas the ratio of BAT to body weight increased markedly. HE staining indicated that the T2DM-RSG rats had increased size of adipocytes in their IWAT, but EA treatment reduced the size of adipocytes. EA effectively reduced the lipid contents without affecting the antidiabetic effect of RSG. Furthermore, we noticed that the expression of PPARγ gene in hypothalamus was reduced by EA, while the expressions of leptin receptor and signal transducer and activator of transcription 3 (STAT3 were increased. Our results suggest that EA is an effective approach for inhibiting weight gain in T2DM rats treated by RSG. The possible mechanism might be through increased levels of leptin receptor and STAT3 and decreased PPARγ expression, by which food intake of the rats was reduced and RSG-induced weight gain was inhibited.

  13. 30 CFR 206.153 - Valuation standards-processed gas.

    Science.gov (United States)

    2010-07-01

    ... reports for royalty purposes is subject to monitoring, review, and audit. For purposes of this section.... (iv) How to value over-delivered volumes under a cash-out program. This paragraph applies to situations where a pipeline purchases gas from a lessee according to a cash-out program under a...

  14. Medication Adherence Improvements in Employees Participating in a Pharmacist-Run Risk Reduction Program

    Directory of Open Access Journals (Sweden)

    Mallory C. McKenzie

    2012-01-01

    Full Text Available Objective: To evaluate the medication adherence of individuals participating in a pharmacist-run employee health Cardiovascular and Diabetes Risk Reduction Program. Design: Retrospective analysis of medication adherence using pharmacy refill data. Setting: A medium sized university located in the Midwest United States and the organization's outpatient pharmacy. Participants: 38 participants ≥ 18 years of age, employed and receiving their health insurance through the organization, and have a diagnosis of hypertension, hyperlipidemia, diabetes mellitus, or a combination thereof. Intervention: Participation in the risk reduction program that emphasizes medication therapy management (MTM, lifestyle medicine and care coordination. Main Outcome Measures: The Proportion of Days Covered (PDC and the Medication Possession Ratio (MPR. Results: PDC and MPR analysis showed a statistically significant improvement in medication adherence for 180 days and 360 days post enrollment versus the 180 days prior to enrollment (P<0.01. The PDC analysis demonstrated a statistically significant improvement in the number of medications that achieved a PDC ≥ 80% (high adherence for the 180 days post enrollment versus the 180 days prior to enrollment (+30%, P<0.01. The MPR analysis showed a non-statistically significant improvement in the number of medications that achieved an MPR ≥ 80% (high adherence pre enrollment versus post enrollment (+10%, P=0.086. The percentage of participants in the program that reached a PDC and MPR adherence rate ≥ 80% at 180 days post enrollment was 78.9% and 94.4%, respectively which exceeds that of a matched cohort that reached a PDC and MPR adherence rate ≥ 80% of 66.4% and 82.8%, respectively. Conclusion: Pharmacists can improve medication adherence as measured by PDC and MPR when working with employees enrolled in a novel pharmacist-run employee health risk reduction program. Medication adherence was shown to be sustainable for

  15. Current Status and Future Works of Neutron Scattering Laboratory at BATAN in Serpong

    International Nuclear Information System (INIS)

    Ikram, A.

    2008-01-01

    Current status of neutron beam instruments using neutrons produced by the Multi Purpose Research Reactor--30MWth (MPR 30, RSG GA Siwabessy) located in Serpong is presented. Description of the reactor as the neutron source is mentioned briefly. There are six neutron beam tubes coming from the beryllium reflector surrounding half of the reactor core providing neutrons in the experimental hall of the reactor (XHR). Four of them are dedicated to R and D in materials science using neutron scattering techniques. Neutron Radiography Facility (NRF), Triple Axis Spectrometer (TAS) and Residual Stress Measurement (RSM) Diffractometer are installed respectively at beam tubes S2, S4 and S6. The largest neutron beam tube (S5) is exploited to accommodate two neutron guide tubes that transfer the neutrons to a neighbouring building called neutron guide hall (NGH). There are three other neutron beam instruments installed in this building, namely Small Angle Neutron Scattering (SANS) Spectrometer (SMARTer), High Resolution SANS (HRSANS) Spectrometer and High Resolution Powder Diffractometer (HRPD). In the XHR, a Four Circle and Texture Diffractometer (FCD/TD) is attached to one of the neutron guide tubes. These seven instruments were installed to utilize the neutrons for materials science research, and recently the RSM diffractometer has shown its capabilities in identifying different amount of stress left due to different treatments of welding in fuel cladding, while the SANS spectrometer is now gaining capabilities in identifying different sizes and shapes of macromolecules in polymers as well as investigations of magnetic samples. In the mean time, non-destructive tests using the NRF is gathering more confidence from some latest real time measurements eventhough there are still some shortcomings in the components and their alignments. Future works including improvement of each facility and its components, even replacement of some parts are necessary and have to be carried out

  16. Impacts of the Grenelle de l'Environnement: must France reduce its greenhouse gas emissions of 30% by 2020?

    International Nuclear Information System (INIS)

    2010-05-01

    Within the international context (Copenhagen agreement), this text analyses efforts made by France to reduce its greenhouse gas emissions, and compares them to those of other countries, notably the United States. Using the NEMESIS model, it also analyses the possible consequences of the present crisis for energy demand and CO 2 emissions. It proposes an assessment of additional efforts to be made to go from 20% to 30% of reduction of these emissions. It tries to assess impacts of investments foreseen by the 'Grenelle de l'Environnement' on activity, GNP, employment, and competitiveness

  17. 30 CFR 206.155 - Accounting for comparison.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Accounting for comparison. 206.155 Section 206... MANAGEMENT PRODUCT VALUATION Federal Gas § 206.155 Accounting for comparison. (a) Except as provided in... the gas the residue gas is not sold pursuant to an arm's-length contract, the value, for royalty...

  18. Natural gas in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    de Voogd, J G

    1965-08-01

    In 1948, the first natural gas was found in Netherlands. Since 1951 it has been supplied by gas undertakings. Originally reserves were limited (c. 350 milliard ftU3D of dry gas in the NE. and c. 175 milliard ftU3D, mostly wet gas, in the SW). These finds have been completely overshadowed by the huge deposits discovered in 1960 in the province of Groningen near the village of Slochteren, these reserves being estimated now at 38.5 billion ftU3D at least. This gas is not of high cal val (894 Btu/ftU3D), but contains only traces of sulfur. The concession is being developed for a partnership formed by Shell (30%), Standard Oil Company of new Jersey (Esso, 30%), and ''Staatsmijnen,'' the Government owned Netherlands State Mining Industry (40%). The natural gas is destined, first, for domestic use, especially, for space heating, and secondly, for industrial purpose, after which important quantities will be available for export.

  19. Comparison of different radiographic methods for the detection of the mandibular canal

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2003-01-01

    To compare the visibility of the mandibular canal at the different radiographic methods such as conventional panoramic radiographs, Vimplant multiplanar reformatting (MPR)-CT panoramic images, Vimplant MPR-CT paraxial images and film-based DentaScan MPR-CT images. Data of 11 mandibular dental implant patients, who had been planned treatment utilizing both panoramic and MPR-CT examination with DentaScan software (GE Medical systems, Milwaukee, USA), were used in this study. The archived axial CT data stored on CD-R discs were transferred to a personal computer with 17' LCD monitor. Paraxial and panoramic images were reconstructed using Vimplant software (CyberMed Inc., Seoul, Korea). Conventional panoramic radiographs, monitor-based Vimplant MPR-CT panoramic images, monitor-based Vimplant MPR-CT paraxial images, and film-based DentaScan MPR-CT images were evaluated for visibility of the mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen using the 4-point grading score. Vimplant MPR-CT panoramic, paraxial, and DentaScan MPR-CT images revealed significantly clearer images than conventional panoramic radiographs. Particularly at the region 1 cm posterior to mental foramen, conventional panoramic radiographs showed a markedly lower percentage of 'excellent' mandibular canal images than images produced by other modalities. Vimplant MPR-CT and DentaScan MPR-CT images did not show significant difference in visibility of the mandibular canal. The study results shoe that Vimplant and DentaScan MPR-CT imaging systems offer significantly better images of the mandibular canal than conventional panoramic radiograph.

  20. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera.

    Science.gov (United States)

    Shiraishi, Shinya; Sakamoto, Fumi; Tsuda, Noriko; Yoshida, Morikatsu; Tomiguchi, Seiji; Utsunomiya, Daisuke; Ogawa, Hisao; Yamashita, Yasuyuki

    2015-01-01

    Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.

  1. An upper and lower bound of the Medication Possession Ratio

    Directory of Open Access Journals (Sweden)

    Sperber CM

    2017-08-01

    Full Text Available Christian M Sperber, Suren R Samarasinghe, Grace P Lomax Patient Connect Limited, Guildford, UK Background: The Medication Possession Ratio (MPR is a ubiquitous and central measurement for adherence in the health care industry. However, attempts to standardize its calculation have failed, possibly due to the opacity of a single, static MPR, incapability of directly lending itself to a variety of studies, and challenges of comparing the value across studies. This work shows that the MPR strictly depends on the length of the time interval over which it is measured as well as on the dominant dispense quantity for short time intervals. Furthermore, removing a proportion of the patient cohort based on the number of acquisitions may also have a severe impact on the MPR. Therefore, it is suggested that the MPR is represented as a trend over a range of time intervals. To this end, an upper and lower bound of the MPR trend is developed with an upper bound acknowledging patients who change their treatment and the lower bound acknowledging patients who discontinue their treatment.Purpose: Introducing a representation of the MPR value as a trend rather than a static number by developing a quantitative description of an upper and lower bound of the MPR trend, while shedding light on the impacts on prefiltering the patient cohort.Patients and methods: Anonymized patient-level data was utilized as an example for a suggested calculation of an upper and lower bound of the MPR.Results: Representation of the MPR for a predefined time interval precludes a reliable MPR assessment. A quantitative approach is suggested to generate an upper and lower trend of the MPR while emphasizing the impact on removing patients with a limited number of acquisitions.Conclusion: An upper and lower trend makes the MPR more transparent and allows a better comparison across different studies. Removing patients with a limited number of acquisitions should be avoided. Keywords: MPR

  2. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [German] Die periphere arterielle Verschlusskrankheit (PAVK) ist eine wesentliche Komplikation des Diabetes mellitus und stellt aufgrund ausgepraegter Gefaessverkalkungen eine diagnostische

  3. Morphology of Gas Release in Physical Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Burns, Carolyn A.; Crawford, Amanda D.; Hylden, Laura R.; Bryan, Samuel A.; MacFarlan, Paul J.; Gauglitz, Phillip A.

    2014-07-03

    This report documents testing activities conducted as part of the Deep Sludge Gas Release Event Project (DSGREP). The testing described in this report focused on evaluating the potential retention and release mechanisms of hydrogen bubbles in underground radioactive waste storage tanks at Hanford. The goal of the testing was to evaluate the rate, extent, and morphology of gas release events in simulant materials. Previous, undocumented scoping tests have evidenced dramatically different gas release behavior from simulants with similar physical properties. Specifically, previous gas release tests have evaluated the extent of release of 30 Pa kaolin and 30 Pa bentonite clay slurries. While both materials are clays and both have equivalent material shear strength using a shear vane, it was found that upon stirring, gas was released immediately and completely from bentonite clay slurry while little if any gas was released from the kaolin slurry. The motivation for the current work is to replicate these tests in a controlled quality test environment and to evaluate the release behavior for another simulant used in DSGREP testing. Three simulant materials were evaluated: 1) a 30 Pa kaolin clay slurry, 2) a 30 Pa bentonite clay slurry, and 3) Rayleigh-Taylor (RT) Simulant (a simulant designed to support DSGREP RT instability testing. Entrained gas was generated in these simulant materials using two methods: 1) application of vacuum over about a 1-minute period to nucleate dissolved gas within the simulant and 2) addition of hydrogen peroxide to generate gas by peroxide decomposition in the simulants over about a 16-hour period. Bubble release was effected by vibrating the test material using an external vibrating table. When testing with hydrogen peroxide, gas release was also accomplished by stirring of the simulant.

  4. PET/CT联合MSCT的多平面重建对孤立性肺结节良恶性鉴别诊断的价值%Evaluation of PET/CT combined with MPR of MSCT in differentiating malignant from benign solitary pulmonary nodules

    Institute of Scientific and Technical Information of China (English)

    马威; 肖勇; 陆普选; 李奕钊; 孟威; 郭晓君; 孙南

    2010-01-01

    目的 探讨PET/CT联合MSCT的多平面重建(MPR)对孤立性肺结节良恶性鉴别诊断的价值.方法 43例孤立性肺结节患者行18F-FDG PET/CT显像和MSCT扫描后进行多平面重建,18F-FDG PET/CT用目测法结合半定量分析法判断良恶性,MSCT的MPR则根据病灶形态学特征判断良恶性,所得18F-FDG PET/CT结果、18F-FDG PET/CT联合MSCT的MPR的结果分别与病理检查结果对照比较.结果 43例SPN中病理及随访证实26例恶性,17例良性.26例恶性SPN中PET/CT显像阳性23例,阴性3例;17例良性SPN中,PET/CT显像阳性7例,阴性10例.18F-FDG PET/CT对恶性结节诊断的敏感性为 88.5%,特异性为58.9%,准确性为76.8%;联合MSCT的MPR,对恶性结节诊断的敏感性为 96.2%,特异性为 76.5%,准确性为88.4%.结论 18F-FDG PET/CT联合MSCT的MPR可以提高SPN良恶性鉴别诊断的准确性.

  5. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  6. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit.

    Science.gov (United States)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Pompucci, Angelo; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo

    2011-12-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180° and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of "CT-like" MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room.

  7. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit

    International Nuclear Information System (INIS)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo; Pompucci, Angelo

    2011-01-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180 and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of ''CT-like'' MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room. (orig.)

  8. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit

    Energy Technology Data Exchange (ETDEWEB)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Desiderio, Flora; D' Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo [Catholic University of Rome, A. Gemelli Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Pompucci, Angelo [Catholic University of Rome, A. Gemelli Hospital, Department of Neurotraumatology, Rome (Italy)

    2011-12-15

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180 and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of ''CT-like'' MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room. (orig.)

  9. Thermodynamic and transport properties of air and its products of combustion with ASTMA-A-1 fuel and natural gas at 20, 30, and 40 atmospheres

    Science.gov (United States)

    Poferl, D. J.; Svehla, R. A.

    1973-01-01

    The isentropic exponent, molecular weight, viscosity, specific heat at constant pressure, thermal conductivity, Prandtl number, and enthalpy were calculated for air, the combustion products of ASTM-A-1 jet fuel and air, and the combustion products of natural gas and air. The properties were calculated over a temperature range from 300 to 2800 K in 100 K increments and for pressures of 20, 30 and 40 atmospheres. The data for natural gas and ASTM-A-1 were calculated for fuel-air ratios from zero to stoichiometric in 0.01 increments.

  10. Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukushima, Hiromichi; Takada, Akira; Mori, Yoshimi; Suzuki, Kojiro; Sawaki, Akiko; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo; Itoh, Shigeki; Ikeda, Mitsuru

    2006-01-01

    The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone. (orig.)

  11. Phenotypic relationships among methane production traits assessed under ad libitum feeding of beef cattle.

    Science.gov (United States)

    Bird-Gardiner, T; Arthur, P F; Barchia, I M; Donoghue, K A; Herd, R M

    2017-10-01

    Angus cattle from 2 beef cattle projects in which daily methane production (MPR) was measured were used in this study to examine the nature of the relationships among BW, DMI, and methane traits of beef cattle fed ad libitum on a roughage diet or a grain-based feedlot diet. In both projects methane was measured using the GreenFeed Emission Monitoring system, which provides multiple short-term breath measures of methane production. The data used for this study were from 119 Angus heifers over 15 d on a roughage diet and 326 Angus steers over 70 d on a feedlot diet. Mean (±SD) age, BW, and DMI were 372 ± 28 d, 355 ± 37 kg, and 8.1 ± 1.3 kg/d for the heifers and 554 ± 86 d, 577 ± 69 kg, and 13.3 ± 2.0 kg/d for the steers, respectively. The corresponding mean MPR was 212 g/d for heifers and 203 g/d for steers. Additional traits studied included methane yield (MY; MPR/DMI), methane intensity (MPR/BW), and 3 forms of residual methane production (RMP), which is a measure of actual minus predicted MPR. For RMP, RMP, and RMP predicted MPR were obtained by regression of MPR on BW, on DMI, and on both DMI and BW, respectively. The 2 data sets were analyzed separately using the same statistical procedures. For both feed types the relationships between MPR and DMI and between MPR and BW were both positive and linear. The correlation between MPR and DMI was similar to that between MPR and BW, although the correlations were stronger for the roughage diet ( = 0.75 for MPR vs. DMI; = 0.74 for MPR vs. BW) than the grain-based diet ( = 0.62 for MPR vs. DMI; = 0.66 for MPR vs. BW). The correlation between MY and DMI was negative and moderate for the roughage ( = -0.68) and grain-based ( = -0.59) diets, a finding that is different from the nonsignificant correlations reported in studies of cattle on a restricted roughage diet. The 3 RMP traits were strongly correlated ( values from 0.76 to 0.99) with each other for both the roughage and the grain-based diets, which indicates

  12. Comparative prediction of irradiation test of CNFT and Cise prototypes of CIRENE fuel pins, a prediction by transuranus M1V1J12 code

    International Nuclear Information System (INIS)

    Suwardi

    2014-01-01

    A prototype of fuel pin design for HWR by CIRENE has been realized by Center for Nuclear Fuel Technology CNFT-BATAN. The prototype will be irradiated in PRTF Power Ramp Test (PRTF). The facility has been installed inside RSG-GA Siwabessy at Serpong. The present paper reports the preparation of experimentation and prediction of irradiation test. One previous PCI test report is found in, written by Lysell G and Valli G in 1973. The CNFT fuel irradiation test parameter is adapted to both PRTF and power loop design for RSG-GAS reactor in Serpong mainly the maxima of: rod length, neutrons flux, total power of rod, and power ramp rate. The CNFT CIRENE prototype design has been reported by Futichah et al 2007 and 2010. The AEC-India HWR fuel pin is of 19/22 fuel bundle design has also been evaluated as comparison. The first PCI test prediction has experiment comparison for Cise pin. The second prediction will be used for optimizing the design of ramp test for CNFT CIRENE fuel pin prototype. (author)

  13. Innovative research reactor core designed. Estimation and analysis of gamma heating distribution

    International Nuclear Information System (INIS)

    Setiyanto

    2014-01-01

    The Gamma heating value is an important factor needed for safety analysis of each experiments that will be realized on research reactor core. Gamma heat is internal heat source occurs in each irradiation facilities or any material irradiated in reactor core. This value should be determined correctly because of the safety related problems. The gamma heating value is in general depend on. reactor core characteristics, different one and other, and then each new reactor design should be completed by gamma heating data. The Innovative Research Reactor is one of the new reactor design that should be completed with any safety data, including the gamma heating value. For this reasons, calculation and analysis of gamma heating in the hole of reactor core and irradiation facilities in reflector had been done by using of modified and validated Gamset computer code. The result shown that gamma heating value of 11.75 W/g is the highest value at the center of reactor core, higher than gamma heating value of RSG-GAS. However, placement of all irradiation facilities in reflector show that safety characteristics for irradiation facilities of innovative research reactor more better than RSG-GAS reactor. Regarding the results obtained, and based on placement of irradiation facilities in reflector, can be concluded that innovative research reactor more safe for any irradiation used. (author)

  14. X-ray observation of the shocked red supergiant wind of Cassiopeia A

    International Nuclear Information System (INIS)

    Lee, Jae-Joon; Park, Sangwook; Hughes, John P.; Slane, Patrick O.

    2014-01-01

    Cas A is a Galactic supernova remnant whose supernova explosion is observed to be of Type IIb from spectroscopy of its light echo. Having its SN type known, observational constraints on the mass-loss history of Cas A's progenitor can provide crucial information on the final fate of massive stars. In this paper, we study X-ray characteristics of the shocked ambient gas in Cas A using the 1 Ms observation carried out with the Chandra X-Ray Observatory and try to constrain the mass-loss history of the progenitor star. We identify thermal emission from the shocked ambient gas along the outer boundary of the remnant. Comparison of measured radial variations of spectroscopic parameters of the shocked ambient gas to the self-similar solutions of Chevalier show that Cas A is expanding into a circumstellar wind rather than into a uniform medium. We estimate a wind density n H ∼ 0.9 ± 0.3 cm –3 at the current outer radius of the remnant (∼3 pc), which we interpret as a dense slow wind from a red supergiant (RSG) star. Our results suggest that the progenitor star of Cas A had an initial mass around 16 M ☉ , and its mass before the explosion was about 5 M ☉ , with uncertainties of several tens of percent. Furthermore, the results suggest that, among the mass lost from the progenitor star (∼11 M ☉ ), a significant amount (more than 6 M ☉ ) could have been via its RSG wind.

  15. Gas reserves, discoveries and production

    International Nuclear Information System (INIS)

    Saniere, A.

    2006-01-01

    Between 2000 and 2004, new discoveries, located mostly in the Asia/Pacific region, permitted a 71% produced reserve replacement rate. The Middle East and the offshore sector represent a growing proportion of world gas production Non-conventional gas resources are substantial but are not exploited to any significant extent, except in the United States, where they account for 30% of U.S. gas production. (author)

  16. Tracing the External Origin of the AGN Gas Fueling Reservoir

    Directory of Open Access Journals (Sweden)

    Sandra I. Raimundo

    2018-01-01

    Full Text Available Near-infrared observations of the active galaxy MCG–6-30-15 provide strong evidence that its molecular gas fueling reservoir is of external origin. MCG–6-30-15 has a counter-rotating core of stars within its central 400 pc and a counter-rotating disc of molecular gas that extends as close as ~50–100 pc from the central black hole. The gas counter-rotation establishes that the gas reservoir in the center of the galaxy originates from a past external accretion event. In this contribution we discuss the gas and stellar properties of MCG–6-30-15, its past history and how the findings on this galaxy can be used to understand AGN fueling in S0 galaxies with counter-rotating structures.

  17. Identification of protein expression alterations in gefitinib-resistant human lung adenocarcinoma: PCNT and mPR play key roles in the development of gefitinib-associated resistance

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chi-Chen [Institute of Biomedical Science, National Chung-Hsing University, Taichung, Taiwan (China); Institute of Biomedical Science, and Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taiwan (China); Department of Medical Research and Education, Taichung Veterans General Hospital, Taichung, Taiwan (China); Division of Chest Medicine, Department of Internal Medicine, Changhua Christian Hospital, Changhua, Taiwan (China); Chen, Jing-Ting [Department of Medical Science and Institute of Bioinformatics and Structural Biology, National Tsing Hua University, Hsinchu, Taiwan (China); Lin, Meng-Wei [Department of Medical Science and Institute of Bioinformatics and Structural Biology, National Tsing Hua University, Hsinchu, Taiwan (China); Department of Applied Science, National Hsinchu University of Education, Hsinchu, Taiwan (China); Chan, Chia-Hao [Department of Obstetrics and Gynecology, Hsinchu Mackay Memorial Hospital, Hsinchu 30071, Taiwan (China); Wen, Yueh-Feng [Department of Medical Science and Institute of Bioinformatics and Structural Biology, National Tsing Hua University, Hsinchu, Taiwan (China); Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu, Taiwan (China); Wu, Shin-Bei [Department of Applied Science, National Hsinchu University of Education, Hsinchu, Taiwan (China); Chung, Ting-Wen [Department of Medical Science and Institute of Bioinformatics and Structural Biology, National Tsing Hua University, Hsinchu, Taiwan (China); Lyu, Kevin W. [Lutheran Medical Center, Brooklyn, NY (United States); Global Scholars Program, St. George' s University/Northumbria University, Newcastle upon Tyne (United Kingdom); Chou, Hsiu-Chuan, E-mail: chouhc@mail.nhcue.edu.tw [Department of Applied Science, National Hsinchu University of Education, Hsinchu, Taiwan (China); and others

    2015-11-01

    Gefitinib is the first-line chemotherapeutic drug for treating non-small cell lung cancer (NSCLC), which comprises nearly 85% of all lung cancer cases worldwide. However, most patients eventually develop drug resistance after 12–18 months of treatment. Hence, investigating the drug resistance mechanism and resistance-associated biomarkers is necessary. Two lung adenocarcinoma cell lines, PC9 and gefitinib-resistant PC9/Gef, were established for examining resistance mechanisms and identifying potential therapeutic targets. Two-dimensional differential gel electrophoresis and matrix-assisted laser desorption ionization time-of-flight mass spectrometry were used for examining global protein expression changes between PC9 and PC9/Gef. The results revealed that 164 identified proteins were associated with the formation of gefitinib resistance in PC9 cells. Additional studies using RNA interference showed that progesterone receptor membrane component 1 and pericentrin proteins have major roles in gefitinib resistance. In conclusion, the proteomic approach enabled identifying of numerous proteins involved in gefitinib resistance. The results provide useful diagnostic markers and therapeutic candidates for treating gefitinib-resistant NSCLC. - Highlights: • 164 proteins associated with gefitinib resistance were identified through proteomic analysis. • In this study, a lung adenocarcinoma and its gefitinib resistant partner were established. • mPR and PCNT proteins have evidenced to play important roles in gefitinib resistance.

  18. Identification of protein expression alterations in gefitinib-resistant human lung adenocarcinoma: PCNT and mPR play key roles in the development of gefitinib-associated resistance

    International Nuclear Information System (INIS)

    Lin, Chi-Chen; Chen, Jing-Ting; Lin, Meng-Wei; Chan, Chia-Hao; Wen, Yueh-Feng; Wu, Shin-Bei; Chung, Ting-Wen; Lyu, Kevin W.; Chou, Hsiu-Chuan

    2015-01-01

    Gefitinib is the first-line chemotherapeutic drug for treating non-small cell lung cancer (NSCLC), which comprises nearly 85% of all lung cancer cases worldwide. However, most patients eventually develop drug resistance after 12–18 months of treatment. Hence, investigating the drug resistance mechanism and resistance-associated biomarkers is necessary. Two lung adenocarcinoma cell lines, PC9 and gefitinib-resistant PC9/Gef, were established for examining resistance mechanisms and identifying potential therapeutic targets. Two-dimensional differential gel electrophoresis and matrix-assisted laser desorption ionization time-of-flight mass spectrometry were used for examining global protein expression changes between PC9 and PC9/Gef. The results revealed that 164 identified proteins were associated with the formation of gefitinib resistance in PC9 cells. Additional studies using RNA interference showed that progesterone receptor membrane component 1 and pericentrin proteins have major roles in gefitinib resistance. In conclusion, the proteomic approach enabled identifying of numerous proteins involved in gefitinib resistance. The results provide useful diagnostic markers and therapeutic candidates for treating gefitinib-resistant NSCLC. - Highlights: • 164 proteins associated with gefitinib resistance were identified through proteomic analysis. • In this study, a lung adenocarcinoma and its gefitinib resistant partner were established. • mPR and PCNT proteins have evidenced to play important roles in gefitinib resistance.

  19. Western Gas Sands Project. Status report, April 1--April 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, C H

    1979-01-01

    Progress of government-sponsored projects directed toward increasing gas production from the low-permeability gas sands of the western United States is summarized. Work by the USGS toward resource assessment in the four primary study areas continued. Bartlesville Energy Technology Center continued work on fracture conductivity, rock-fluid interaction, and log evaluation and interpretation techniques. Experimental and theoretical work on hydraulic fracturing mechanics and analysis of well test data continued at Lawrence Livermore Laboratory. Gathering of bottom-hole pressure data from the Miller No. 1 well and Sprague No. 1 well in the Wattenberg Field, Colorado continued. Fracturing fluid/rock interaction tests have been completed by Terra Tek for Gas Producing Enterprises, Inc., on sandstone horizons in the lower Mesaverde. The Mitchell Energy Corporation Muse-Duke No. 1 was flowed 4,000 MCFGD in April. Fishing operations on the Mobil PCU F31-13G well were unsuccessful. Six zones of the first horizontal experimental hole in the Sandia Laboratories interface test series were mined back to examine the behavior of the hydraulic fracture at the interface. Data collection by CER Corporation and TRW for GRI's Analysis of Tight Formations project continued.

  20. RSG-Gas Based Radioisotopes And Sharing Program For Regional Back Up Supply

    International Nuclear Information System (INIS)

    Soenardjo, Sunarhadijoso; Tamat, Swasono R.; Suparman, Ibon; Purwadi, Bambang

    2003-01-01

    As the owner of the reactors used for radioisotope production, BATAN needs to increase the effectiveness of the reactor operation cost that can be achieved by simultaneously exploiting all the existing irradiation facility, supported by full utilization of the radioisotopes produced. On the other hand, the domestic demand of radioisotopes is much lower than the production capability but sometimes the request is compulsory to be suspended due to reactor operation schedule. As this condition is mostly similar to that of several countries of RCA Member States, a sharing program for regional back up supply seems to be a positive thought to support expectation on the effectiveness of reactor operation cost and the continuity of radioisotope product services as well as the utilization of radioisotopes produced. Based on radioactivity achieved in each production batch at the present, 131 I, 99 Mo, 153 Sm, 125 I and 32 p radioisotopes may be offered for back up supply program. Due to consideration on conformity of user demands with reactor operation and radiochemical processing costs, the concept of back up supply program should performed first by means of full utilization of the available products and not by increasing reactor operation frequency. An information and communication network system, therefore, is absolutely needed to support information exchange between the radioisotope producer, members of back up supply program and radioisotope customers

  1. Safety analysis of RSG-GAS Silicide core using one line cooling system

    International Nuclear Information System (INIS)

    Endiah-Puji-Hastuti

    2003-01-01

    In the frame of minimizing the operation-cost, operation mode using one line cooling system is being evaluated. Maximum reactor has been determined and to continuing this program, steady state and transient analysis were done. The analysis was done by means of a core thermal hydraulic code, COOLOD-N, and PARET. The codes solves core thermal hydraulic equation at steady state conditions and transient, respectively. By using silicide core data and coast down flow rate as the input, thermal hydraulics parameters such as fuel cladding and fuel meat temperatures as well as safety margin against flow instability were calculated. Imposing the safety criteria to the results of steady state and transient analysis, maximum permissible power for this operation was obtained as much as 17.1 MW

  2. 30 CFR 250.1200 - Question index table.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Question index table. 250.1200 Section 250.1200 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR... Security § 250.1200 Question index table. The table in this section lists questions concerning Oil and Gas...

  3. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  4. Shale gas - los yacimientos de hidrocarburos no convencionales: origen del Shale gas

    Directory of Open Access Journals (Sweden)

    José Francisco Longoria Treviño

    2015-06-01

    Full Text Available El shale gas tiene su origen en la acumulación de materia orgánica en cuencas marinas. En Norteamérica el gas de lutita (shale gas es una fuente emergente de gas natural de bajo costo. El gas natural es una fuente de energía abundante y relativamente limpia al quemarse. Se ha convertido en un combustible popular tanto para aplicaciones residenciales como industriales. De acuerdo con los datos recientes se estima que el suministro de gas natural derivado de yacimientos no convencionales (gas de lutita – shale gas durará más de 100 años. El gas natural ofrece un remplazo potencial para sustituir a los combustibles fósiles que producen gases de efecto invernadero y que en la actualidad se usan en la generación de energía, calefacción y transporte. Las emisiones de gas de efecto invernadero de la combustión de gas natural son aproximadamente 30% más limpias que aquellas que se derivan del aceite y 45% más limpias de las del carbón.

  5. Gas cooled reactor assessment. Volume II. Final report, February 9, 1976--June 30, 1976

    International Nuclear Information System (INIS)

    1976-08-01

    This report was prepared to document the estimated power plant capital and operating costs, and the safety and environmental assessments used in support of the Gas Cooled Reactor Assessment performed by Arthur D. Little, Inc. (ADL), for the U.S. Energy Research and Development Administration. The gas-cooled reactor technologies investigated include: the High Temperature Gas Reactor Steam Cycle (HTGR-SC), the HTGR Direct Cycle (HTGR-DC), the Very High Temperature Reactor (VHTR) and the Gas Cooled Fast Reactor (GCFR). Reference technologies used for comparison include: Light Water Reactors (LWR), the Liquid Metal Fast Breeder Reactor (LMFBR), conventional coal-fired steam plants, and coal combustion for process heat

  6. 75 FR 28032 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings

    Science.gov (United States)

    2010-05-19

    ... Institute Special Emphasis Panel, NHLBI DNA Resequencing and Genotyping (RS&G) Service: Administrative..., NHLBI DNA Resequencing and Genotyping (RS&G) Service: Laboratory Center(s). Date: June 4, 2010. Time: 2... Nos. 93.233, National Center for Sleep Disorders Research; 93.837, Heart and Vascular Diseases...

  7. Electricity and gas market observatory. 2. Quarter 2008

    International Nuclear Information System (INIS)

    2008-01-01

    The purpose of the observatory is to provide the general public with indicators for monitoring market deregulation. It both covers the wholesale and retail electricity and gas markets in Metropolitan France. This observatory is updated every three months and data are available on CRE web site (www.cre.fr). Since the 1 of July 2007, all customers can choose their gas and electricity suppliers. Content: A - The electricity market: The retail electricity market (Introduction, Customer segments and their respective weight, Status at June 30, 2008, Dynamic analysis: 2. Quarter 2008); The wholesale electricity market (Introduction, Wholesale market activity in France, Prices on the French wholesale market and European comparison, Import and export volumes, Concentration of the French electricity market); B - The gas market: The retail gas market (Introduction, Customer segments and their respective weight, Status on June 30, 2008, Dynamic analysis: 2. Quarter 2008); The wholesale gas market (Gas pricing and gas markets in Europe, The wholesale market in France); C - Appendices: Electricity and gas market observatories combined glossary, Specific electricity market observatory glossary, Specific gas market observatory glossary

  8. Improved Synthesis of β-D-6-Methylpurine Riboside and Antitumor Effects of the β-D- and α-D-Anomers

    Directory of Open Access Journals (Sweden)

    J. Sufrin

    2005-08-01

    Full Text Available 6-Methylpurine-β-D-riboside (β-D-MPR has been synthesized by coupling6-methylpurine and 1-O-acetyl-2,3,5-tri-O-benzoyl-D-ribose using conditions that producethe β-D-anomer exclusively. The in vitro antitumor effects of β-D-MPR and 6-methyl-purine-α-D-riboside (α-D-MPR in five human tumor cell lines showed that β-D-MPR washighly active (IC50 values ranging from 6 to 34 nM. α-D-MPR, although less active than β-D-MPR, also exhibited significant antitumor effects (IC50 values ranging from 1.47 to 4.83"µ"M.

  9. Phosphorylation of the cytoplasmic tail of the 300-kDa mannose 6-phosphate receptor is required for the interaction with a cytosolic protein

    DEFF Research Database (Denmark)

    Rosorius, O; Issinger, O G; Braulke, T

    1993-01-01

    The cytoplasmic tail of the human 300-kDa mannose 6-phosphate receptor (MPR 300-CT) is an excellent substrate for casein kinase II in vitro. The phosphorylated MPR 300-CT was cross-linked by means of bis(sulfosuccinimidyl)suberate mainly to a cytosolic protein of 35 kDa (referred to as TIP 35...... with TIP 35 is phosphorylation-specific. Furthermore, TIP 35 was only cross-linked to the MPR 300-CT phosphorylated by casein kinase II whereas the MPR 300-CT phosphorylated by protein kinase A failed to cross-link to TIP 35. These results indicate that the cytoplasmic tail of the MPR 300 interacts...

  10. Magnetohydrodynamics: Parallel computation of the dynamics of thermonuclear and astrophysical plasmas. 1. Annual report of massively parallel computing pilot project 93MPR05

    International Nuclear Information System (INIS)

    1994-08-01

    This is the first annual report of the MPP pilot project 93MPR05. In this pilot project four research groups with different, complementary backgrounds collaborate with the aim to develop new algorithms and codes to simulate the magnetohydrodynamics of thermonuclear and astrophysical plasmas on massively parallel machines. The expected speed-up is required to simulate the dynamics of the hot plasmas of interest which are characterized by very large magnetic Reynolds numbers and, hence, require high spatial and temporal resolutions (for details see section 1). The four research groups that collaborated to produce the results reported here are: The MHD group of Prof. Dr. J.P. Goedbloed at the FOM-Institute for Plasma Physics 'Rijnhuizen' in Nieuwegein, the group of Prof. Dr. H. van der Vorst at the Mathematics Institute of Utrecht University, the group of Prof. Dr. A.G. Hearn at the Astronomical Institute of Utrecht University, and the group of Dr. Ir. H.J.J. te Riele at the CWI in Amsterdam. The full project team met frequently during this first project year to discuss progress reports, current problems, etc. (see section 2). The main results of the first project year are: - Proof of the scalability of typical linear and nonlinear MHD codes - development and testing of a parallel version of the Arnoldi algorithm - development and testing of alternative methods for solving large non-Hermitian eigenvalue problems - porting of the 3D nonlinear semi-implicit time evolution code HERA to an MPP system. The steps that were scheduled to reach these intended results are given in section 3. (orig./WL)

  11. Magnetohydrodynamics: Parallel computation of the dynamics of thermonuclear and astrophysical plasmas. 1. Annual report of massively parallel computing pilot project 93MPR05

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-08-01

    This is the first annual report of the MPP pilot project 93MPR05. In this pilot project four research groups with different, complementary backgrounds collaborate with the aim to develop new algorithms and codes to simulate the magnetohydrodynamics of thermonuclear and astrophysical plasmas on massively parallel machines. The expected speed-up is required to simulate the dynamics of the hot plasmas of interest which are characterized by very large magnetic Reynolds numbers and, hence, require high spatial and temporal resolutions (for details see section 1). The four research groups that collaborated to produce the results reported here are: The MHD group of Prof. Dr. J.P. Goedbloed at the FOM-Institute for Plasma Physics `Rijnhuizen` in Nieuwegein, the group of Prof. Dr. H. van der Vorst at the Mathematics Institute of Utrecht University, the group of Prof. Dr. A.G. Hearn at the Astronomical Institute of Utrecht University, and the group of Dr. Ir. H.J.J. te Riele at the CWI in Amsterdam. The full project team met frequently during this first project year to discuss progress reports, current problems, etc. (see section 2). The main results of the first project year are: - Proof of the scalability of typical linear and nonlinear MHD codes - development and testing of a parallel version of the Arnoldi algorithm - development and testing of alternative methods for solving large non-Hermitian eigenvalue problems - porting of the 3D nonlinear semi-implicit time evolution code HERA to an MPP system. The steps that were scheduled to reach these intended results are given in section 3. (orig./WL).

  12. Demand for storage of natural gas in northwestern Europe: Trends 2005-30

    International Nuclear Information System (INIS)

    Hoeffler, Felix; Kuebler, Madjid

    2007-01-01

    We provide an estimation of the additional need for underground storage facilities in northwestern Europe until 2030. Storage is one important source to provide supply flexibility in order to match the seasonal demand for natural gas. However, this supply flexibility is now largely provided in northwestern Europe by indigenous production. Declining reserves will increase the dependency on imports from far-off sources, which are less flexible. Hence, flexibility must be provided by additional storage. Our estimation is based on production and consumption forecasts for natural gas and observations of the relationship between the supply and demand of gas and the supply and demand of flexibility in the period 1995-2005. We provide different scenarios to check for the robustness of our results. We estimate that by 2030, between 10.2 (with no strategic storage) and 29.0 billion cubic meters (BCM) of working gas volume (with 10 percent strategic storage for imports from non-EU countries) will be required, in addition to the existing 40 BCM. We conclude that, with well-functioning markets for flexibility, market forces could close a storage gap of 10.2 BCM in time. Strategic storage obligations would require state intervention and a well-balanced relation between a regulated part of the storage market for strategic reserves and the market for the operational use of storage

  13. Western Gas Sands Project. Status report, 1 June--30 June 1979

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This edition of the WGSP status report summarizes June 1979 progress of government-sponsored projects directed toward increasing gas production from the low-permeability gas sands of the western United States. Background information is provided in the September 1977, status report, NVO/0655-100. Work by the USGS toward resource assessment in the four primary study areas continued. CK GeoEnergy started a core hole in Grand County, Utah. During June, projects of the National Laboratories and Energy Technology Centers continued. Bartlesville Energy Technology Center continued work on fracture conductivity, rock-fluid interaction, and log evaluation and interpretation techniques. Experimental and theoretical work on hydraulic fracturing mechanics and analysis of well test data continued at Lawrence Livermore Laboratory. The CER Corporation RB-MHF 3 final report has been distributed. Cyclic gas injection began again on CIG's Sprague No. 1 well. The DOE well test facility was transported to Vernal, Utah for minor repairs and storage. The GPE wells, Natural Buttes Units 9, 14 and 18 flowed to sales. The Mitchell Energy Muse-Duke No. 1 well flowed 3,000 MCFD in June. Attempts to kill the Mobil PCU F31-13G well failed. Exploratory coring of the Sandia Hole No. 6 Formation Interface Fracture Experiment resumed in June.

  14. GAS STORAGE TECHNOLOGY CONSORTIUM

    Energy Technology Data Exchange (ETDEWEB)

    Robert W. Watson

    2004-10-18

    Gas storage is a critical element in the natural gas industry. Producers, transmission and distribution companies, marketers, and end users all benefit directly from the load balancing function of storage. The unbundling process has fundamentally changed the way storage is used and valued. As an unbundled service, the value of storage is being recovered at rates that reflect its value. Moreover, the marketplace has differentiated between various types of storage services, and has increasingly rewarded flexibility, safety, and reliability. The size of the natural gas market has increased and is projected to continue to increase towards 30 trillion cubic feet (TCF) over the next 10 to 15 years. Much of this increase is projected to come from electric generation, particularly peaking units. Gas storage, particularly the flexible services that are most suited to electric loads, is critical in meeting the needs of these new markets. In order to address the gas storage needs of the natural gas industry, an industry-driven consortium was created--the Gas Storage Technology Consortium (GSTC). The objective of the GSTC is to provide a means to accomplish industry-driven research and development designed to enhance operational flexibility and deliverability of the Nation's gas storage system, and provide a cost effective, safe, and reliable supply of natural gas to meet domestic demand. To accomplish this objective, the project is divided into three phases that are managed and directed by the GSTC Coordinator. The first phase, Phase 1A, was initiated on September 30, 2003, and was completed on March 31, 2004. Phase 1A of the project included the creation of the GSTC structure, development and refinement of a technical approach (work plan) for deliverability enhancement and reservoir management. This report deals with Phase 1B and encompasses the period July 1, 2004, through September 30, 2004. During this time period there were three main activities. First was the

  15. Semi-annual report for the unconventional gas recovery program, period ending September 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Manilla, R.D. (ed.)

    1980-11-01

    Progress is reported in research on methane recovery from coalbeds, eastern gas shales, western gas sands, and geopressured aquifers. In the methane from coalbeds project, data on information evaluation and management, resource and site assessment and characterization, model development, instrumentation, basic research, and production technology development are reported. In the methane from eastern gas shales project, data on resource characterization and inventory, extraction technology, and technology testing and verification are presented. In the western gas sands project, data on resource assessments, field tests and demonstrations and project management are reported. In the methane from geopressured aquifers project, data on resource assessment, supporting research, field tests and demonstrations, and technology transfer are reported.

  16. Treatment interruptions and non-adherence with imatinib and associated healthcare costs: a retrospective analysis among managed care patients with chronic myelogenous leukaemia.

    Science.gov (United States)

    Darkow, Theodore; Henk, Henry J; Thomas, Simu K; Feng, Weiwei; Baladi, Jean-Francois; Goldberg, George A; Hatfield, Alan; Cortes, Jorge

    2007-01-01

    Identify treatment interruptions and non-adherence with imatinib; examine the clinical and patient characteristics related to treatment interruptions and non-adherence; and estimate the association between treatment interruptions and non-adherence with imatinib and healthcare costs for US managed care patients with chronic myeloid leukaemia (CML). This retrospective analysis utilised electronic healthcare claims data from a US managed care provider. Adult patients with CML (as determined by International Classification of Diseases, ninth revision, Clinical Modification [ICD-9-CM] diagnosis code) were identified who began treatment with imatinib from 1 June 2001 through 31 March 2004. Treatment interruptions (i.e. failure to refill imatinib within 30 days from the run-out date of the prior prescription) were identified during the 12-month follow-up period. Medication possession ratio (MPR), calculated as total days' supply of imatinib divided by 365, was also examined. Healthcare costs (i.e. paid amounts for all prescription medications and medical services received, including health plan and patient liability) were examined in three ways: (i) total healthcare costs; (ii) total healthcare costs exclusive of imatinib costs; and (iii) total medical costs. All costs were converted to US dollars (2004 values) using the medical component of the Consumer Price Index. MPR was modelled using ordinary least squares regression. Presence of treatment interruptions was modelled using logistic regression. The association between MPR and healthcare costs was estimated using a generalised linear model specified with a gamma error distribution and a log link. All models included adjustment for age, gender, number of concomitant medications, starting dose of imatinib and cancer complexity. A total of 267 patients were identified. Average age was approximately 50 years, and 43% were women. Mean MPR was 77.7%, with 31% of patients having a treatment interruption. However, all of these

  17. 30 CFR 77.303 - Hot gas inlet chamber dropout doors.

    Science.gov (United States)

    2010-07-01

    ... Section 77.303 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... employ a hot gas inlet chamber shall be equipped with drop-out doors at the bottom of the inlet chamber...

  18. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Schabel, C.; Bongers, M.N.; Syha, R.; Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F.; Thomas, C.

    2015-01-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [de

  19. Greenhouse gas emissions from high demand, natural gas-intensive energy scenarios

    International Nuclear Information System (INIS)

    Victor, D.G.

    1990-01-01

    Since coal and oil emit 70% and 30% more CO 2 per unit of energy than natural gas (methane), fuel switching to natural gas is an obvious pathway to lower CO 2 emissions and reduced theorized greenhouse warming. However, methane is, itself, a strong greenhouse gas so the CO 2 advantages of natural gas may be offset by leaks in the natural gas recovery and supply system. Simple models of atmospheric CO 2 and methane are used to test this hypothesis for several natural gas-intensive energy scenarios, including the work of Ausubel et al (1988). It is found that the methane leaks are significant and may increase the total 'greenhouse effect' from natural gas-intensive energy scenarios by 10%. Furthermore, because methane is short-lived in the atmosphere, leaking methane from natural gas-intensive, high energy growth scenarios effectively recharges the concentration of atmospheric methane continuously. For such scenarios, the problem of methane leaks is even more serious. A second objective is to explore some high demand scenarios that describe the role of methane leaks in the greenhouse tradeoff between gas and coal as energy sources. It is found that the uncertainty in the methane leaks from the natural gas system are large enough to consume the CO 2 advantages from using natural gas instead of coal for 20% of the market share. (author)

  20. Community males show multiple-perpetrator rape proclivity: development and preliminary validation of an interest scale.

    Science.gov (United States)

    Alleyne, Emma; Gannon, Theresa A; Ó Ciardha, Caoilte; Wood, Jane L

    2014-02-01

    The literature on Multiple Perpetrator Rape (MPR) is scant; however, a significant proportion of sexual offending involves multiple perpetrators. In addition to the need for research with apprehended offenders of MPR, there is also a need to conduct research with members of the general public. Recent advances in the forensic literature have led to the development of self-report proclivity scales. These scales have enabled researchers to conduct evaluative studies sampling from members of the general public who may be perpetrators of sexual offenses and have remained undetected, or at highest risk of engaging in sexual offending. The current study describes the development and preliminary validation of the Multiple-Perpetrator Rape Interest Scale (M-PRIS), a vignette-based measure assessing community males' sexual arousal to MPR, behavioral propensity toward MPR and enjoyment of MPR. The findings show that the M-PRIS is a reliable measure of community males' sexual interest in MPR with high internal reliability and temporal stability. In a sample of university males we found that a large proportion (66%) did not emphatically reject an interest in MPR. We also found that rape-supportive cognitive distortions, antisocial attitudes, and high-risk sexual fantasies were predictors of sexual interest in MPR. We discuss these findings and the implications for further research employing proclivity measures referencing theory development and clinical practice.

  1. Electricity and gas market observatory. 3. Quarter 2007

    International Nuclear Information System (INIS)

    2007-01-01

    The purpose of the observatory is to provide the general public with indicators for monitoring market deregulation. It both covers the wholesale and retail electricity and gas markets in Metropolitan France. This observatory is updated every three months and data are available on CRE web site (www.cre.fr). Since the 1 of July 2007, all customers can choose their gas and electricity suppliers. The present observatory is including residential customer's statistics. Content: A - The electricity market: The retail electricity market (Introduction, Customer segments and their respective weight, Status at September 30, 2007, Dynamic analysis: 3. Quarter 2007); The wholesale electricity market (Introduction, Wholesale market activity in France, Wholesale market activity in France, Prices on the French wholesale market and European comparison, Import and export volumes, Concentration of the French electricity market); B - The gas market: The retail gas market (Introduction, Customer segments and their respective weight, Status on September 30, 2007, Dynamic analysis: 3. Quarter 2007); The wholesale gas market (Gas pricing and gas markets in Europe, The wholesale market in France); C - Appendices: Electricity and gas market observatories combined glossary, Specific electricity market observatory glossary, Specific gas market observatory glossary

  2. Design Of The Canal System Of KLA-60 Condensation Produce

    International Nuclear Information System (INIS)

    Sriawan; Wiranto, Slamet

    2000-01-01

    The RSG-GAS reactor pool ventilation system (KLA-60) which be used to avoid circulation of contamination air in the reactor hall, flow the 60% air from the pool surface to stack through the various filters. In case the isolation building the air from the pool surface is flooded back to the operation hall after exceed the heat exchanger, cooler and the various filters. One of the weakness of this system and must be solved by RSG is handing of the condensation water because in the canal system of the KLA-60 condensation produce is to be found some soiled like algae and to go the reactor pool. To solve this problem should be carried out research about the canal system of KLA-60 condensation produce and design the new canal system to find the good function. At the first design is carried out study about the function of the old of canal system of KLA-60 condensation produce. Base on this study have been carried out design of the canal system KLA-60 condensation produce, with can prevent the soiled to go to the reactor pool

  3. Understanding vented gas explosions

    Energy Technology Data Exchange (ETDEWEB)

    Lautkaski, R. [VTT Energy, Espoo (Finland). Energy Systems

    1997-12-31

    The report is an introduction to vented gas explosions for nonspecialists, particularly designers of plants for flammable gases and liquids. The phenomena leading to pressure generation in vented gas explosions in empty and congested rooms are reviewed. The four peak model of vented gas explosions is presented with simple methods to predict the values of the individual peaks. Experimental data on the external explosion of dust and gas explosions is discussed. The empirical equation relating the internal and external peak pressures in vented dust explosions is shown to be valid for gas explosion tests in 30 m{sup 3} and 550 m{sup 3} chambers. However, the difficulty of predicting the internal peak pressure in large chambers remains. Methods of explosion relief panel design and principles of vent and equipment layout to reduce explosion overpressures are reviewed. (orig.) 65 refs.

  4. Understanding vented gas explosions

    Energy Technology Data Exchange (ETDEWEB)

    Lautkaski, R [VTT Energy, Espoo (Finland). Energy Systems

    1998-12-31

    The report is an introduction to vented gas explosions for nonspecialists, particularly designers of plants for flammable gases and liquids. The phenomena leading to pressure generation in vented gas explosions in empty and congested rooms are reviewed. The four peak model of vented gas explosions is presented with simple methods to predict the values of the individual peaks. Experimental data on the external explosion of dust and gas explosions is discussed. The empirical equation relating the internal and external peak pressures in vented dust explosions is shown to be valid for gas explosion tests in 30 m{sup 3} and 550 m{sup 3} chambers. However, the difficulty of predicting the internal peak pressure in large chambers remains. Methods of explosion relief panel design and principles of vent and equipment layout to reduce explosion overpressures are reviewed. (orig.) 65 refs.

  5. Serum phosphorus levels and pill burden are inversely associated with adherence in patients on hemodialysis.

    Science.gov (United States)

    Wang, Steven; Alfieri, Thomas; Ramakrishnan, Karthik; Braunhofer, Peter; Newsome, Britt A

    2014-11-01

    Phosphate binders (PBs) account for about one half of the daily pill burden for US hemodialysis (HD) patients, which may reduce adherence. Adherence can be estimated by the medication possession ratio (MPR), which is defined as the proportion of time a patient had sufficient medication to have taken it as prescribed. Gaps of time between prescription fills lower the patient's MPR. We assessed the association of PB pill burden and adherence (MPR) with phosphorus goal attainment. Using pharmacy management program data, HD patients on PB monotherapy were tracked from first PB fill during 1 January 2007-30 June 2011 for 1 year, or until PB change or censoring. Data were assessed with generalized linear models. We analyzed 8616 patients. Higher pill burden was associated with lower adherence. Lower adherence tended to be associated with higher mean phosphorus levels and lower percentage of patients with serum phosphorus ≤5.5 mg/dL (P adherence and these clinical outcomes was most pronounced in the lowest and highest pill burden strata (3-6, >12-15, >15). Adherence, as measured by the MPR, was negatively related to higher pill burden and phosphorus levels and positively related to patients in the phosphorus target range. Within pill burden strata, phosphorus increased and patients in the target range generally decreased with decreasing adherence, suggesting that patients prescribed fewer PB pills are less likely to have treatment gaps, and may be more likely to achieve phosphorus targets. © The Author 2013. Published by Oxford University Press on behalf of ERA-EDTA.

  6. The Jarvis gas release incident

    International Nuclear Information System (INIS)

    Manocha, J.

    1992-01-01

    On 26 September, 1991, large volumes of natural gas were observed to be leaking from two water wells in the Town of Jarvis. Gas and water were being ejected from a drilled water well, at which a subsequent gas explosion occurred. Measurements of gas concentrations indicated levels far in excess of the lower flammability limit at several locations. Electrical power and natural gas services were cut off, and residents were evacuated. A state of emergency was declared, and gas was found to be flowing from water wells, around building foundations, and through other fractures in the ground. By 27 September the volumes of gas had reduced substantially, and by 30 September all residents had returned to their homes and the state of emergency was cancelled. The emergency response, possible pathways of natural gas into the aquifer, and public relations are discussed. It is felt that the likelihood of a similar incident occurring in the future is high. 11 figs

  7. Amplification without inversion, fast light and optical bistability in a duplicated two-level system

    International Nuclear Information System (INIS)

    Ebrahimi Zohravi, Lida; Vafafard, Azar; Mahmoudi, Mohammad

    2014-01-01

    The optical properties of a weak probe field in a duplicated two-level system are investigated in multi-photon resonance (MPR) condition and beyond it. It is shown that by changing the relative phase of applied fields, the absorption switches to the amplification without inversion in MPR condition. By applying the Floquet decomposition to the equations of motion beyond MPR condition, it is shown that the phase-dependent behavior is valid only in MPR condition. Moreover, it is demonstrated that the group velocity of light pulse can be controlled by the intensity of the applied fields and the gain-assisted superluminal light propagation (fast light) is obtained in this system. In addition, the optical bistability (OB) behavior of the system is studied beyond MPR condition. We apply an indirect incoherent pumping field to the system and it is found that the group velocity and OB behavior of the system can be controlled by the incoherent pumping rate. - Highlights: • We studied the optical properties of DTL system under MPR condition and beyond it. • By changing the relative phase, the absorption switches to the amplification without inversion in MPR condition. • The gain-assisted superluminal light propagation (fast light) is obtained in this system. • The optical bistability (OB) behavior of the system is studied beyond MPR condition. • The incoherent pumping rate has a major role in controlling the group velocity and OB behavior of the system

  8. Mechanisms of generation of membrane potential resonance in a neuron with multiple resonant ionic currents.

    Directory of Open Access Journals (Sweden)

    David M Fox

    2017-06-01

    Full Text Available Neuronal membrane potential resonance (MPR is associated with subthreshold and network oscillations. A number of voltage-gated ionic currents can contribute to the generation or amplification of MPR, but how the interaction of these currents with linear currents contributes to MPR is not well understood. We explored this in the pacemaker PD neurons of the crab pyloric network. The PD neuron MPR is sensitive to blockers of H- (IH and calcium-currents (ICa. We used the impedance profile of the biological PD neuron, measured in voltage clamp, to constrain parameter values of a conductance-based model using a genetic algorithm and obtained many optimal parameter combinations. Unlike most cases of MPR, in these optimal models, the values of resonant- (fres and phasonant- (fϕ = 0 frequencies were almost identical. Taking advantage of this fact, we linked the peak phase of ionic currents to their amplitude, in order to provide a mechanistic explanation the dependence of MPR on the ICa gating variable time constants. Additionally, we found that distinct pairwise correlations between ICa parameters contributed to the maintenance of fres and resonance power (QZ. Measurements of the PD neuron MPR at more hyperpolarized voltages resulted in a reduction of fres but no change in QZ. Constraining the optimal models using these data unmasked a positive correlation between the maximal conductances of IH and ICa. Thus, although IH is not necessary for MPR in this neuron type, it contributes indirectly by constraining the parameters of ICa.

  9. Central European gas market perspectives

    International Nuclear Information System (INIS)

    Vanous, Jan

    1999-01-01

    This presentation deals with (1) Definition of the Central European market, (2) Factors driving up consumption of natural gas in Central and Eastern Europe, (3) Role of natural gas in regional energy consumption, (4) Position of natural gas in individual country markets, (5) Future sources of imported natural gas into the region. The Central European market are the eleven countries Albania, Bulgaria, Croatia, Czech Republic, Hungary, Macedonia, Poland, Romania, Serbia and Montenegro, Slovakia, and Slovenia, with a total population of 121 million. This market is comparable to combined France and Italy in terms of population, but only 30% of its size in terms of GDP

  10. 30 CFR 250.463 - Who establishes field drilling rules?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Who establishes field drilling rules? 250.463... GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Other Drilling Requirements § 250.463 Who establishes field drilling rules? (a) The District Manager may...

  11. 30 CFR 206.174 - How do I value gas production when an index-based method cannot be used?

    Science.gov (United States)

    2010-07-01

    ... to consider include prices received in spot sales of gas, residue gas or gas plant products, other... part, or timely, for a quantity of gas, residue gas, or gas plant product. (j) Non-binding MMS reviews..., DEPARTMENT OF THE INTERIOR MINERALS REVENUE MANAGEMENT PRODUCT VALUATION Indian Gas § 206.174 How do I value...

  12. Bi-gas pilot plant operation. Technical progress report, 1 July 1980-30 September 1980

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The stainless steel process gas line from the gasifier to the gas washer was replaced with chrome molybdenum steel. Test G-13 was the longest to date and was characterized by smooth start-up and operation, long Stage I thermocouple life, and collection of much material balance data. Stress corrosion cracking in several areas of the process gas line delayed start-up of Test G-14 and a large part of the quarter was spent in replacing this piping. The results of test G-13 are described in detail. Conclusions for the test and recommendation are given, especially for burner modifications, prevention of calcium carbonate deposits, etc.

  13. Analysis of slipped capital femoral epiphysis

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Sponseller, P.D.; Griffin, P.P.

    1988-01-01

    CT with multiplanar reconstruction (CT/MPR) was used to assess 25 adolescents with known or suspected slipped capital femoral epiphysis (SCFE). CT/MPR localizes the epiphysis in three planes, establishing its relationship to the acetabulum and the metaphyseal neck. MPR facilitates measurements of head-neck angles, residusal head-neck contact, and relative retrovision. CT/MPR may establish the true age of the epiphyseal failure and can reveal subtle SCFE in the face of normal plain films. Patients often present with confusing histories; clues to the true age of failure include subtle signs of healing, remodeling, or new bone buttressing. Characterization of acute versus chronic conditions influences preoperative planning. Postoperatively, CT/MPR confirms early results and follows epiphyseal fusion and remodelling. It also detects complications, such as pin or graft migration avascular necrosis (AVN), or chondrolysis

  14. Low-level radioactive gas monitor for natural gas operations

    International Nuclear Information System (INIS)

    Armstrong, F.E.

    1969-11-01

    A portable radioactivity detection system for monitoring the tritium content of natural gas under field conditions has been developed. The sensing device employed is a complex proportional counting assembly operated without the use of massive shielding previously employed with such low-level radiation detectors. The practical limit of detection for the system is a tritium content of 10 -9 microcurie per cc of natural gas. All components of the system are packaged in three waterproof cases weighing slightly less than 30 kg each. Power requirement is 500 watts of 120 volt, 60 Hz current. Operation is fully automatic with a printed record produced at predetermined time intervals

  15. Valid MR imaging predictors of prior knee arthroscopy

    International Nuclear Information System (INIS)

    Discepola, Federico; Le, Huy B.Q.; Park, John S.; Clopton, Paul; Knoll, Andrew N.; Austin, Matthew J.; Resnick, Donald L.

    2012-01-01

    To determine whether fibrosis of the medial patellar reticulum (MPR), lateral patellar reticulum (LPR), deep medial aspect of Hoffa's fat pad (MDH), or deep lateral aspect of Hoffa's fat pad (LDH) is a valid predictor of prior knee arthroscopy. Institutional review board approval and waiver of informed consent were obtained for this HIPPA-compliant study. Initially, fibrosis of the MPR, LPR, MDH, or LDH in MR imaging studies of 50 patients with prior knee arthroscopy and 100 patients without was recorded. Subsequently, two additional radiologists, blinded to clinical data, retrospectively and independently recorded the presence of fibrosis of the MPR in 50 patients with prior knee arthroscopy and 50 without. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting the presence of fibrosis in the MPR were calculated. κ statistics were used to analyze inter-observer agreement. Fibrosis of each of the regions examined during the first portion of the study showed a significant association with prior knee arthroscopy (p < 0.005 for each). A patient with fibrosis of the MPR, LDH, or LPR was 45.5, 9, or 3.7 times more likely, respectively, to have had a prior knee arthroscopy. Logistic regression analysis indicated that fibrosis of the MPR supplanted the diagnostic utility of identifying fibrosis of the LPR, LDH, or MDH, or combinations of these (p ≥ 0.09 for all combinations). In the second portion of the study, fibrosis of the MPR demonstrated a mean sensitivity of 82%, specificity of 72%, PPV of 75%, NPV of 81%, and accuracy of 77% for predicting prior knee arthroscopy. Analysis of MR images can be used to determine if a patient has had prior knee arthroscopy by identifying fibrosis of the MPR, LPR, MDH, or LDH. Fibrosis of the MPR was the strongest predictor of prior knee arthroscopy. (orig.)

  16. Valid MR imaging predictors of prior knee arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Discepola, Federico; Le, Huy B.Q. [McGill University Health Center, Jewsih General Hospital, Division of Musculoskeletal Radiology, Montreal, Quebec (Canada); Park, John S. [Annapolis Radiology Associates, Division of Musculoskeletal Radiology, Annapolis, MD (United States); Clopton, Paul; Knoll, Andrew N.; Austin, Matthew J.; Resnick, Donald L. [University of California San Diego (UCSD), Division of Musculoskeletal Radiology, San Diego, CA (United States)

    2012-01-15

    To determine whether fibrosis of the medial patellar reticulum (MPR), lateral patellar reticulum (LPR), deep medial aspect of Hoffa's fat pad (MDH), or deep lateral aspect of Hoffa's fat pad (LDH) is a valid predictor of prior knee arthroscopy. Institutional review board approval and waiver of informed consent were obtained for this HIPPA-compliant study. Initially, fibrosis of the MPR, LPR, MDH, or LDH in MR imaging studies of 50 patients with prior knee arthroscopy and 100 patients without was recorded. Subsequently, two additional radiologists, blinded to clinical data, retrospectively and independently recorded the presence of fibrosis of the MPR in 50 patients with prior knee arthroscopy and 50 without. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting the presence of fibrosis in the MPR were calculated. {kappa} statistics were used to analyze inter-observer agreement. Fibrosis of each of the regions examined during the first portion of the study showed a significant association with prior knee arthroscopy (p < 0.005 for each). A patient with fibrosis of the MPR, LDH, or LPR was 45.5, 9, or 3.7 times more likely, respectively, to have had a prior knee arthroscopy. Logistic regression analysis indicated that fibrosis of the MPR supplanted the diagnostic utility of identifying fibrosis of the LPR, LDH, or MDH, or combinations of these (p {>=} 0.09 for all combinations). In the second portion of the study, fibrosis of the MPR demonstrated a mean sensitivity of 82%, specificity of 72%, PPV of 75%, NPV of 81%, and accuracy of 77% for predicting prior knee arthroscopy. Analysis of MR images can be used to determine if a patient has had prior knee arthroscopy by identifying fibrosis of the MPR, LPR, MDH, or LDH. Fibrosis of the MPR was the strongest predictor of prior knee arthroscopy. (orig.)

  17. 30 CFR 281.28 - Royalty.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Royalty. 281.28 Section 281.28 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.28 Royalty. (a...

  18. 30 CFR 281.26 - Payments.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Payments. 281.26 Section 281.26 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.26 Payments. (a...

  19. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  20. Characterization of phosphorylation sites in the cytoplasmic domain of the 300 kDa mannose-6-phosphate receptor

    DEFF Research Database (Denmark)

    Rosorius, O; Mieskes, G; Issinger, O G

    1993-01-01

    The human 300 kDa mannose-6-phosphate receptor (MPR 300) is phosphorylated in vivo at serine residues of its cytoplasmic domain. Two-dimensional separation can resolve tryptic phosphopeptides into four major species. To identify the kinases involved in MPR 300 phosphorylation and the phosphorylat......The human 300 kDa mannose-6-phosphate receptor (MPR 300) is phosphorylated in vivo at serine residues of its cytoplasmic domain. Two-dimensional separation can resolve tryptic phosphopeptides into four major species. To identify the kinases involved in MPR 300 phosphorylation...... and the phosphorylation sites the entire coding sequence of the cytoplasmic tail was expressed in Escherichia coli. The isolated cytoplasmic domain was used as a substrate for four purified serine/threonine kinases [casein kinase II (CK II), protein kinase A (PKA), protein kinase C and Ca2+/calmodulin kinase]. All...... kinases phosphorylate the cytoplasmic tail exclusively on serine residues. Inhibition studies using synthetic peptides, partial sequencing of isolated tryptic phosphopeptides and co-migration with tryptic phosphopeptides from MPR 300 labelled in vivo showed that (i) PKA phosphorylates the cytoplasmic MPR...

  1. Elements and gas enrichment laws of sweet spots in shale gas reservoir: A case study of the Longmaxi Fm in Changning block, Sichuan Basin

    Directory of Open Access Journals (Sweden)

    Renfang Pan

    2016-05-01

    Full Text Available Identification of sweet spot is of great significance in confirming shale gas prospects to realize large-scale economic shale gas development. In this paper, geological characteristics of shale gas reservoirs were compared and analyzed based on abundant data of domestic and foreign shale gas reservoirs. Key elements of sweet spots were illustrated, including net thickness of gas shale, total organic carbon (TOC content, types and maturity (Ro of organic matters, rock matrix and its physical properties (porosity and permeability, and development characteristics of natural fractures. After the data in Changning and Weiyuan blocks, the Sichuan Basin, were analyzed, the geologic laws of shale gas enrichment were summarized based on the economic exploitation characteristics of shale gas and the correlation between the elements. The elements of favorable “sweet spots” of marine shale gas reservoirs in the Changning block and their distribution characteristics were confirmed. Firstly, the quality of gas source rocks is ensured with the continuous thickness of effective gas shale larger than 30 m, TOC > 2.0% and Ro = 2.4–3.5%. Secondly, the quality of reservoir is ensured with the brittle minerals content being 30–69%, the clay mineral content lower than 30% and a single lamination thickness being 0.1–1.0 m. And thirdly, the porosity is higher than 2.0%, the permeability is larger than 50 nD, gas content is higher than 1.45 m3/t, and formation is under normal pressure–overpressure system, which ensures the production modes and capacities. Finally, the primary and secondary elements that control the “sweet spots” of shale gas reservoirs were further analyzed and their restrictive relationships with each other were also discussed.

  2. Examining the Effect of Medication Adherence on Risk of Subsequent Fracture Among Women with a Fragility Fracture in the U.S. Medicare Population.

    Science.gov (United States)

    Keshishian, Allison; Boytsov, Natalie; Burge, Russel; Krohn, Kelly; Lombard, Louise; Zhang, Xiang; Xie, Lin; Baser, Onur

    2017-11-01

    In the United States, osteoporosis affects approximately 10 million people, of whom 80% are women, and it contributes a significant clinical burden to the community. Poor adherence to osteoporosis medications adds to the overall burden of illness. To examine the association of osteoporosis medication adherence and the risk of a subsequent fracture among Medicare-enrolled women with a previous fragility fracture. This study was a retrospective observational analysis of U.S. administrative claims data among female Medicare beneficiaries who had a nontrauma closed fragility fracture between January 1, 2011, and December 31, 2011. Patients were required to have continuous medical and pharmacy enrollment 12 months pre- and postfracture date. In addition, patients were required to have an osteoporosis medication prescription for a bisphosphonate (alendronate, risedronate, pamidronate, etidronate, zoledronate, and tiludronate), calcitonin, denosumab, raloxifene, or teriparatide during the follow-up period. Adherence was calculated using cumulative medication possession ratio (MPR) from the treatment initiation date in 30-day increments. MPR was stratified into high adherence (MPR ≥ 80%), moderate adherence (50% ≤ MPR > 80%), and low adherence (MPR 80%; n = 4,602, 16.6%). After adjusting for demographics and clinical characteristics, patients with low and moderate adherence to osteoporosis medications were 33% (hazard ratio [HR] = 1.33; 95% CI = 1.17-1.50, P Eli Lilly. Xie, Keshishian, and Baser are employees of STATinMED Research, a paid consultant to Eli Lilly in connection with the study design, data analysis, and development of the manuscript for this study. Boytsov, Burge, Lombard, and Zhang are employees and stock owners of Eli Lilly. At the time of research, Krohn was an employee of Eli Lilly. Study concept and design were contributed by Burge and Lombard, along with the other authors. Xie, Baser, and Keshishian took the lead in data collection, assisted by the

  3. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    ... chemical bonds can be established between the SiO2 silanol surface groups and the MPR carboxylic chains, to render SiO2/MPR core-shell-type compounds. The presence of PFR or MPR resins during the sol–gel production of silica microspheres allows to control: the sizes of final SiO2 particles and; the transparency or ...

  4. Maternal protein restriction compromises myocardial contractility in the young adult rat by changing proteins involved in calcium handling.

    Science.gov (United States)

    de Belchior, Aucelia C S; Freire, David D; da Costa, Carlos P; Vassallo, Dalton V; Padilha, Alessandra S; Dos Santos, Leonardo

    2016-02-01

    Maternal protein restriction (MPR) during pregnancy is associated with increased cardiovascular risk in the offspring in adulthood. In this study we evaluated the cardiac function of young male rats born from mothers subjected to MPR during pregnancy, focusing on the myocardial mechanics and calcium-handling proteins. After weaning, rats received normal diet until 3 mo old, when the following parameters were assessed: arterial and left ventricular hemodynamics and in vitro cardiac contractility in isolated papillary muscles. The body weight was lower and arterial pressure higher in the MPR group compared with young adult offspring of female rats that received standard diet (controls); and left ventricle time derivatives increased in the MPR group. The force developed by the cardiac muscle was similar; but time to peak and relaxation time were longer, and the derivatives of force were depressed in the MPR. In addition, MPR group exhibited decreased post-pause potentiation of force, suggesting reduced reuptake function of the sarcoplasmic reticulum. Corroborating, the myocardial content of SERCA-2a and phosphorylated PLB-Ser16/total PLB ratio was decreased and sodium-calcium exchanger was increased in the MPR group. The contraction dependent on transsarcolemmal influx of calcium was higher in MPR if compared with the control group. In summary, young rats born from mothers subjected to protein restriction during pregnancy exhibit changes in the myocardial mechanics with altered expression of calcium-handling proteins, reinforcing the hypothesis that maternal malnutrition is related to increased cardiovascular risk in the offspring, not only for hypertension, but also cardiac dysfunction. Copyright © 2016 the American Physiological Society.

  5. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  6. Reliability Prediction Of System And Component Of Process System Of RSG-GAS Reactor

    International Nuclear Information System (INIS)

    Sitorus Pane, Jupiter

    2001-01-01

    The older the reactor the higher the probability of the system and components suffer from loss of function or degradation. This phenomenon occurred because of wear, corrosion, and fatigue. Study on component reliability was generally performed deterministically and statistically. This paper would describe an analysis of using statistical method, i.e. regression Cox, in order to predict the reliability of the components and their environmental influence's factors. The result showed that the dynamics, non safety related, and mechanic components have higher risk of failure, whereas static, safety related, and electric have lower risk of failures. The relative risk value for variable of components dynamics, quality, dummy 1 and dummy 2 are of 1.54, 1.59, 1.50, and 0.83 compare to other components type with each variable. Component with the higher risk have lower reliability than lower one

  7. Calculation of Plutonium content in RSG-GAS spent fuel using IAFUEL computer code

    International Nuclear Information System (INIS)

    Mochamad-Imron

    2003-01-01

    It has been calculated the contain of isotopes Pu-239, Pu-240, Pu-241, and isotope Pu-242 in MTR reactor fuel types which have U-235 contain about 250 gram. The calculation was performed in three steps. The first step is to determine the library of calculation output of BOC (Beginning of Cycle). The second step is to determine the core isotope density, the weight of plutonium for one core, and one fuel isotope density. The third step is to calculate weight of plutonium in gram. All calculation is performed by IAFUEL computer code. The calculation was produced content of each Pu isotopes were Pu-239 is 6.7666 gr, Pu-240 is 1.4628 gr, Pu-241 is 0.52951 gr, and Pu-242 is 0.068952 gr

  8. Evaluate Influence to Space Lighting Intensity in Main Control Room of RSG-GAS

    International Nuclear Information System (INIS)

    Teguh-Sulistyo; Yuyut-S-M; Yahya; Adin S

    2006-01-01

    Have been done by an activity evaluate factor depreciation influence to light source in Main Control Room (RKU). This Factor Depreciation is resulted from by defilement of effect of dirt, duration of light source utilized, way of installation, and others. Method used by perceives directly at light source, determining measurement dot in space RKU, measurement by using meter lux equipment and group storey; level depreciation of light source become light depreciation, and heavy. Than measurement result that lighting intensity in space RKU experience of decrease of equal to 1.5 %. After by stage; steps overcome the factor depreciation, result of measurement repeat obtained by decrease of equal to 0.87 %. Thereby the lighting intensity in space RKU becomes better. (author)

  9. Natural-gas supply-and-demand problems

    International Nuclear Information System (INIS)

    Hatamian, H.

    1998-01-01

    World natural-gas consumption quadrupled in the 30 years from 1966 to 1996, and natural gas now provides 22% of the total world energy demand. The security of natural-gas supply is paramount and rests with the suppliers and the consumers. This paper gives an overview of world natural-gas supply and demand and examines the main supply problems. The most important nonpredictable variables in natural-gas supply are worldwide gas price and political stability, particularly in regions with high reserves. Other important considerations are the cost of development/processing and the transport of natural gas to market, which can be difficult to maintain if pipelines pass through areas of political instability. Another problem is that many countries lack the infrastructure and capital for effective development of their natural-gas industry. Unlike oil, the cost of transportation of natural gas is very high, and, surprisingly, only approximately 16% of the total world production currently is traded internationally

  10. Excellent enhancement of corrosion properties of Fe–9Al–30Mn–1.8C alloy in 3.5% NaCl and 10% HCl aqueous solutions using gas nitriding treatment

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yung-Chang; Lin, Chih-Lung; Chao, Chuen-Guang; Liu, Tzeng-Feng, E-mail: Lewischen815@gmail.com

    2015-06-05

    Highlights: • The FeAlMnC alloy was gas-nitrided to simultaneously achieve the aging effect. • Anti-corrosion components AlN, Fe{sub 3}N and Fe{sub 4}N were identified by using GIXRD method. • The present nitrided alloy showed a great improvement in corrosion resistance. • The nitrided sample showed an excellent coherence between nitrided layer and matrix. • The nitrided and then stretched sample maintained satisfactory corrosion behavior. - Abstract: The as-quenched Fe–9.0Al–30Mn–1.8C (in wt.%) alloy gas nitrided at 550 °C for 4 h show excellent corrosion resistance investigated in 3.5% NaCl and 10% HCl solutions. Owing to the high corrosion resistance components, the gas-nitrided layer consists mainly of AlN with a slight amount of Fe{sub 3}N and Fe{sub 4}N identified by grazing incidence X-ray diffraction technique. Therefore, the pitting potential and corrosion potential of the nitrided sample are +1860 mV and +30 mV, respectively. Surprisingly, it is worthy to be pointed out that the nitrided and then tensile-tested alloy reveals very shallow in fracture depth and the excellent lattice coherence is shown between the nitrided layer and the substrate. Moreover, due to the extremely high nitrogen concentration (about 17–18 wt.%) at stretched surface, the corrosion resistance of present gas-nitrided and then tensile-tested alloy is superior to those optimally gas-nitrided or plasma-nitrided high-strength alloy steels, as well as martensitic stainless steels. The nitrided and then stretched alloy still retains a satisfactory corrosion resistance (E{sub pit} = +890 mV; E{sub corr} = +10 mV). Furthermore, only nanoscale-size pits were observed on the corroded surface after being immersed in 10% HCl for 24 h.

  11. Design and performance of BWC replacement steam generators for PWR systems

    International Nuclear Information System (INIS)

    Klarner, R.; Steinmoeller, F.; Millman, J.; Schneider, W.

    1998-01-01

    In recent years, Babcock and Wilcox Canada (BWC) has provided a number of PWR Replacement Steam Generators (RSGS) to replace units that had experienced extensive Alloy 600 tube degradation. BWC RSG units are in operation at Northeast Utilities' Millstone Unit 2, Rochester Gas and Electric's Ginna Station, Duke Energy's Catawba Unit 1, McGuire Unit 1 and 2, Florida Power and Light's St. Lucie Unit 1 and Commonwealth Edison's Byron 1 Station. Extensive start-up performance characteristics have been obtained for Millstone 2, Ginna, McGuire 1, and Catawba 1 RSGS. The Millstone 2, Ginna and Catawba 1 RSGs have also undergone extensive inspections following their first cycle of operation. The design and start-up performance characteristics of these RSGs are presented. The BWC Replacement Steam generators were designed to fit the existing envelope of pressure boundary dimensions to ensure licensability and integration into the Nuclear Steam Supply System. The RSGs were provided with a tube bundle of Alloy 690TT tubing, sized to match or exceed the original steam generator (OSG) thermal performance including provision for the reduced thermal conductivity of Alloy 690 relative to Alloy 600. The RSG tube bundle configurations provide a higher circulation design relative to the OSG, and feature corrosion resistant lattice grid and U-bend tube supports which provide effective anti-vibration support. The tube bundle supports accommodate relatively unobstructed flow and allow unrestrained structural interactions during thermal transients. Efficient steam separators assure low moisture carryover as well as high circulation. Performance measurements obtained during start-up verify that the BWC RSGs meet or exceed the specified thermal and moisture carryover performance requirements. RSG water level stability results at nor-mal operation and during plant transients have been excellent. Visual and ECT inspections have confirmed minimal deposition and 100% tube integrity following

  12. Preoperative examination of potential renal transplant donors: value of gadolinium-enhanced 3D-MR-angiography in comparison with DSA and urography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Paul, G.; Einert, A.; Altehoefer, C.; Uhrmeister, P.; Laubenberger, J.

    2000-01-01

    Purpose: To assess a contrast-enhanced standardized MRA protocol for the presurgical evaluation of potential renal transplant donors. Methods: Twenty-three potential donors for renal transplantations were examined with gadolinium-enhanced, two-phase MR angiograms (1.5 T) and DSA/urography for the number of renal arteries, the presence of aberrant arterial and venous branches, renal artery stenoses and anatomy of the renal collecting system and ureters. The diagnostic value was assessed by evaluating different image processing modalities and interobserver variability. Results: Using maximum intensity projections (MIP) together with multiplanar reformatting (MPR), accessory arteries were detected with a sensitivity/specificity of 100%/98%. Depending on diagnostic experience, exclusive evaluation of MIP yielded a sensitivitiy/specificity of 67-100%/95-100%. Using MIP/MPR, venous depiction was good in 80%, with MIP solely in 30-40%. At least the proximal third of the ureter was visible in 67%. Conclusion: MPR/MIP evaluation of two-phase, contrast-enhanced MRA provides an excellent depiction of renal vessel anatomy for presurgical evaluation of renal transplant donors. Exclusive MIP assessment is less reliable and depends strongly on the examiner's experience. For sufficient visualization of the ureters, either additional measurements or low-dose diuretic injection have to be performed. (orig.) [de

  13. Flue gas emissions from gas-fired cogeneration units <25 MWe

    International Nuclear Information System (INIS)

    Nielsen, M.; Wit, J. de

    1997-01-01

    A total of 900 MW e gas driven combined heat and power (CHP) has now been established in Denmark based on gas engines and gas turbine units less than 25 MW e each. Of the 900 MW e approx. 750 MW e are based on gas engines. Biogas is used as fuel for some 32 MW e of these. Emission limits for NO x and CO are 650 mg/nm 3 (ref. 5% O 2 and electrical efficiency 30% LCV). There is at present no limit for unburned hydrocarbons (UHC) for gas engines or gas turbines. The average emission of unburned hydrocarbons for the Danish gas engine driven CHP units is equal to approx. 3,5% of the fuel used. It is the target of this report to provide the basis for evaluating the planned UHC limit and possible adjustments of the present limit for NO x emission. The average NO x emission from gas turbines slightly exceeds the NO x emission from gas engines. This is due to a number of older gas turbines. Modern gas turbines can achieve significantly lower NO x emission compared to engines. The NO x emission from biogas driven engines is significantly higher than that of natural gas driven units. This is mainly due to NO x -unfavourable engine settings and the use of older units, as there are no legislation concerning NO x emission for the majority of these biogas driven units. The emission of CO and UHC is lower from gas turbines than from gas engines. The NO x emission can be reduced by SCR Catalyst systems. In Denmark 3 gas engine installations use this commercially available technology. Oxidation catalyst for UHC reduction at modern gas engine installations has proven relatively unsuccesful in Denmark until now. Only limited reductions are achieved and many catalysts are toxificated in less than 100 hours of operation. However, long-term field testing of promising UHC reducing catalysts is now being made. UHC reduction by incineration is at the prototype stage. No such plant has yet been set up in Denmark. (Abstract Truncated)

  14. 30 CFR 250.414 - What must my drilling prognosis include?

    Science.gov (United States)

    2010-07-01

    ...) Projected plans for logging; (c) Planned safe drilling margin between proposed drilling fluid weights and... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What must my drilling prognosis include? 250... OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations...

  15. Report on the French gas market opening

    International Nuclear Information System (INIS)

    Syrota, J.

    2002-10-01

    This document takes stock on the french gas market opening since august 2000, implementation of the 98/30/CE directive and proposes recommendations on main questions of the future gas regulations. These questions concern the situation and forecast of the competition in Europe, the access tariffing to the transport networks and to the liquefied natural gas installations, the modalities of the network access for the third (ATR), the juridical aspects. (A.L.B.)

  16. Comparison of technical and physical activities between 8 vs. 8 and 11 vs. 11 games in young Korean soccer players.

    Science.gov (United States)

    Oh, Seong Hwan; Joo, Chang Hwa

    2018-04-01

    The aims of this study were to examine the differences in technical aspects and physical demands between small-size games (SSG; 8 vs. 8) and regular-size games (RSG; 11 vs. 11) in young Korean soccer players. Seventy-nine young soccer players from 6 teams (U-12) volunteered to participate in the study. The players completed 4 games (2 SSG, 62×51 m, and 2 RSG, 80×54 m) in 2 days. Each game was filmed to evaluate technical actions. Physical demand variables were measured using global positioning system technology. SSG showed significantly greater numbers of technical plays among 17 variables when compared to RSG ( P game format for Korean young soccer players, resulting in significantly greater exposure to technical plays without excessive physical demands.

  17. Gas war, the Russian threat

    International Nuclear Information System (INIS)

    Ougartchinska, R.; Carre, J.M.

    2008-01-01

    This book presents an anticipated vision of tomorrow's Western Europe's dependence of Russia's gas reserves. With an overpriced oil and diminishing reserves, Europe is standing by. The energy majors are considering the possibility to reconvert their activities towards clean gas, cheaper and available. Energy needs are going to double within the next twenty years but the question remains: where supplying from? A 'blue gold' rush is preparing, accompanied by inextricable conflicts. Gas is in the center of this east-west 'big game' with one certainty: Russia owns more than a third of the World's natural gas reserves, Russia is the first world gas producer and exporting country, and tomorrow it is going to become the inescapable supplier who imposes its law. An excessive power is offered to the former soviet empire which has patiently weaved its gas web for more than 30 years. According to the authors, if Europe got caught in Russia's net, it is also because it let it do so

  18. Ionised gas structure of 100 kpc in an over-dense region of the galaxy group COSMOS-Gr30 at z 0.7

    Science.gov (United States)

    Epinat, B.; Contini, T.; Finley, H.; Boogaard, L. A.; Guérou, A.; Brinchmann, J.; Carton, D.; Michel-Dansac, L.; Bacon, R.; Cantalupo, S.; Carollo, M.; Hamer, S.; Kollatschny, W.; Krajnović, D.; Marino, R. A.; Richard, J.; Soucail, G.; Weilbacher, P. M.; Wisotzki, L.

    2018-01-01

    We report the discovery of a 104 kpc2 gaseous structure detected in [O II]λλ3727, 3729 in an over-dense region of the COSMOS-Gr30 galaxy group at z 0.725 with deep MUSE Guaranteed Time Observations. We estimate the total amount of diffuse ionised gas to be of the order of ( 5 ± 3) × 1010 M⊙ and explore its physical properties to understand its origin and the source(s) of the ionisation. The MUSE data allow the identification of a dozen group members that are embedded in this structure through emission and absorption lines. We extracted spectra from small apertures defined for both the diffuse ionised gas and the galaxies. We investigated the kinematics and ionisation properties of the various galaxies and extended gas regions through line diagnostics (R23, O32, and [O III]/Hβ) that are available within the MUSE wavelength range. We compared these diagnostics to photo-ionisation models and shock models. The structure is divided into two kinematically distinct sub-structures. The most extended sub-structure of ionised gas is likely rotating around a massive galaxy and displays filamentary patterns that link some galaxies. The second sub-structure links another massive galaxy that hosts an active galactic nucleus (AGN) to a low-mass galaxy, but it also extends orthogonally to the AGN host disc over 35 kpc. This extent is likely ionised by the AGN itself. The location of small diffuse regions in the R23 vs. O32 diagram is compatible with photo-ionisation. However, the location of three of these regions in this diagram (low O32, high R23) can also be explained by shocks, which is supported by their high velocity dispersions. One edge-on galaxy shares the same properties and may be a source of shocks. Regardless of the hypothesis, the extended gas seems to be non-primordial. We favour a scenario where the gas has been extracted from galaxies by tidal forces and AGN triggered by interactions between at least the two sub-structures. Based on observations made with

  19. The cost of longer-run gas supply to Europe

    International Nuclear Information System (INIS)

    Odell, P. R.

    1996-01-01

    The supply, demand and price outlook for natural gas in Europe were examined in detail. Demand for natural gas estimated to grow an average of 2.3% per annum, which will increase import dependence from 130 to 320 BCM over the next 30 years. For the immediate future profitable indigenous supply was predicted, aided by large proven and probable reserves, and technological advances. Indigenous output was forecast to increase by some 60% by 2025. Future international oil prices indicate gas-equivalent border values adequate to secure profitable supply from a variety of external sources leading to continuing competition for markets by producers and continuing diversification of imports. 30 refs., 9 tabs

  20. 30 CFR 282.3 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... from such activity. Contingency Plan means a plan for action to be taken in emergency situations. Data... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Definitions. 282.3 Section 282.3 Mineral... CONTINENTAL SHELF FOR MINERALS OTHER THAN OIL, GAS, AND SULPHUR General § 282.3 Definitions. When used in this...

  1. Separation of krypton from dissolver off-gas of a reprocessing plant using preparative gas chromatography

    International Nuclear Information System (INIS)

    Matoni, M.

    1984-02-01

    Kr-85 can be separated from the pre-purified purge air in the final processing step of the purification phase for dissolver off-gases of a reprocessing plant with the aid of preparative gas chromatography. Activated carbon adsorbers in combination with helium as carrier gas permits maximum gas mixture through-flow. A separation temperature of 30 0 C is considered optimal. An adsorbent volume of 40 dm 3 is necessary for processing the residual gas flow of 2.5 Nm 3 /h; the adsorbent is divided between 2 columns linked in series each of which are 2 m long with an internal diameter of 100 mm. The helium flow required is five times greater than the off-gas flow. The degree of purity for krypton is greater than 90% for a decontamination factor of greater than 1000. (orig./HP) [de

  2. Oil and natural gas

    International Nuclear Information System (INIS)

    Riddell, C.H.

    1993-01-01

    The natural gas industry and market prospects in Canada are reviewed from a producer's point of view. In the first eight months of 1993, $2.3 billion in new equity was raised for natural gas exploration and production, compared to $900 million in 1991 and $1.2 billion in 1992. The number of wells drilled in the western Canada basin is expected to reach 8,000-9,000 in 1993, up from 5,600 in 1992, and Canadian producers' share of the North American natural gas market will probably reach 20% in 1993, up from 13% in 1986. Potential and proved gas supply in North America is ca 750 trillion ft 3 , of which ca 30% is in Canada. Factors affecting gas producers in Canada are the deregulated nature of the market, low costs for finding gas (finding costs in the western Canada basin are the lowest of any basin in North America), and the coming into balance of gas supply and demand. The former gas surplus has been reduced by expanding markets and by low prices which reduced the incentive to find new reserves. This surplus is largely gone, and prices have started rising although they are still lower than the pre-deregulation prices. Progress is continuing toward an integrated North American gas market in which a number of market hubs allow easy gas trading between producers and consumers. Commodity exchanges for hedging gas prices are beginning operation and electronic trading of gas contracts and pipeline capacity will also become a reality. 4 figs

  3. Two Year Longitudinal Change and Test-Retest-Precision of Knee Cartilage Morphology in a Pilot Study for the Osteoarthritis Initiative

    Science.gov (United States)

    Eckstein, Felix; Kunz, Manuela; Schutzer, Matt; Hudelmaier, Martin; Jackson, Rebecca D.; Yu, Joseph; Eaton, Charles B.; Schneider, Erika

    2009-01-01

    Objective Fast low angle shot (FLASH) and double echo steady state (DESS) MRI sequences were recently cross-calibrated for quantification of cartilage morphology at 3 Tesla. In this pilot study for the Osteoarthritis Initiative we compare their test-retest precision and sensitivity to longitudinal change. Method 9 participants with mild to moderate clinical OA were imaged at baseline, year 1 and year 2. Coronal 1.5mm FLASH and sagittal 0.7mm DESS sequences were acquired; 1.5mm coronal multiplanar reformats (MPR) were obtained from the DESS. Patellar, femoral and tibial cartilage plates were quantified in paired fashion, with blinding to time point. Results In the weight-bearing femorotibial joint, average precision errors across plates were 1.8% for FLASH, 2.6% for DESS, and 3.0% for MPR-DESS. Volume loss at year 1 was not significant; at year 2 the average change across the femorotibial cartilage plates was −1.7% for FLASH, −2.8% for DESS, and −0.3% for MPR-DESS. Volume change in the lateral tibia (−5.5%; p<0.03), and in the medial (−2.9%; p<0.04) and lateral femorotibial compartment (−3.8%; p<0.03) were significant for DESS. Conclusion FLASH, MPR-DESS and DESS all displayed adequate test-retest precision. Although the comparison between protocols is limited by the small number of participants and by the relatively small longitudinal change in cartilage morphology in this pilot study, the data suggest that significant change can be detected with MRI in a small sample of OA subjects over 2 years. PMID:17560813

  4. Multiplanar reconstructed CT images increased depiction of intracranial hemorrhages in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Langford, Stacey; Panigrahy, Ashok; Narayanan, Srikala; Hwang, Misun; Fitz, Charles; Flom, Lynda; Lee, Vincent Kyu; Zuccoli, Giulio [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Section of Neuroradiology, Pittsburgh, PA (United States)

    2015-12-15

    The benefits of multiplanar reconstructed images (MPR) of unenhanced axial head computed tomography (CT) data have not been established in trauma patients younger than 3 years old, a population in which a reliable history and physical examination may be most difficult. We retrospectively evaluated unenhanced head CTs in pediatric trauma patients to investigate the various benefits of MPR in this age group. A total of 221 unenhanced head CTs performed for any case of head trauma (HT) on children younger than 3 years old were independently reviewed by two radiologists. Studies were reviewed first in the standard axial plane alone and then with the addition of MPR. Reviewers were asked to determine if the MPR affected the ability to make findings of hemorrhage, incidental findings, and artifacts. MPR improved the detection of hemorrhage in 14 cases (6.5 %, p-value < 0.01) and incidental findings in five cases (2.3 %, p-value < 0.05) as well as helped prove artifacts in five cases (2.3 %, p-value < 0.05). Routine use of MPR in HT patients younger than 3 years old has the potential to increase the detection of acute and incidental imaging findings. (orig.)

  5. Electric power geneation and other gas market opportunities

    International Nuclear Information System (INIS)

    Lucy, M.S.

    1991-01-01

    The future market for natural gas in the northeast USA is discussed. A strong market demand for natural gas is foreseen to continue because of the need for clean burning electric generation facilities and the low saturation of overall natural gas use in the northeast. Although total gas sales increased 30% in the northeast from 1978 to 1989, and conversion of commercial businesses and houses to natural gas use is increasing, the northeast still remains highly dependent on oil as an energy source. For example, nearly 60% of all the oil used to generate electricity and ca 70% of all the home heating oil used the USA is burned in the northeast. The northeast currently receives ca 4.3 billion ft 3 /d of gas, 80% from Louisiana and Texas. With the addition of a number of pipeline projects, another 4.2 billion ft 3 /d will be added by 1992. Power demand is growing, and many New England generation plants are 30 years old or more and in need of upgrading. Natural gas is the fuel of choice for new installations because of pollution regulations, low capital costs, competitive gas pricing, and other factors. A recent report projects that ca 68% of the planned cogeneration capacity in New England will be fuelled by natural gas, requiring an additional 200.7 billion ft 3 /d in the northeast. Another market with strong potential for continued growth is the residential sector, where only 61% of households with gas service use gas for heating. Natural gas vehicle development is being stimulated by mandates for alternative fuelled vehicle fleets; an increase in gas demand of 600 billion ft 3 by 2005 is projectd, based on increased use of natural gas vehicles. 2 figs., 6 tabs

  6. Heavy ion source support gas mixing experiments

    International Nuclear Information System (INIS)

    Hudson, E.D.; Mallory, M.L.

    1977-01-01

    Experiments on mixing an easily ionized support gas with the primary ion source gas have produced large beam enhancements for high charge state light ions (masses less than or equal to 20). In the Oak Ridge Isochronous Cyclotron (ORIC), the beam increase has been a factor of 5 or greater, depending on ion species and charge state. Approximately 0.1 cc/min of the easily ionized support gas (argon, krypton, or xenon) is supplied to the ion source through a separate gas line and the primary gas flow is reduced by approximately 30 percent. The proposed mechanism for increased intensity is as follows: The heavier support gas ionizes readily to a higher charge state, providing increased cathode heating. The increased heating permits a reduction in primary gas flow (lower pressure) and the subsequent beam increase

  7. 30 CFR 281.29 - Royalty valuation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Royalty valuation. 281.29 Section 281.29 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.29...

  8. 30 CFR 281.31 - Overriding royalties.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Overriding royalties. 281.31 Section 281.31 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.31...

  9. Metal oxide membranes for gas separation

    Science.gov (United States)

    Anderson, Marc A.; Webster, Elizabeth T.; Xu, Qunyin

    1994-01-01

    A method for permformation of a microporous ceramic membrane onto a porous support includes placing a colloidal suspension of metal oxide particles on one side of the porous support and exposing the other side of the porous support to a drying stream of gas or a reactive gas stream so that the particles are deposited on the drying side of the support as a gel. The gel so deposited can be sintered to form a supported ceramic membrane having mean pore sizes less than 30 Angstroms and useful for ultrafiltration, reverse osmosis, or gas separation.

  10. Lightning protection system analysis at Multipurpose Reactor G A. Siwabessy building

    International Nuclear Information System (INIS)

    Teguh-Sulistyo

    2003-01-01

    Analysis to the part of lightning protection system at Multi Purpose Reactor GA Siwabessy (RSG-GAS) have been done. Observation examined the damage of some part of the earthing system caused by human error of chemically system. The analysis performed some assumptions and simulations to the points of lightning stroke. From this analysis obtained that the reactor building do not have vertical finial which can protect effectively to the whole reactor building and auxiliary building. Installing some new finials at some places are needed to protect building therefore the reactor building and auxiliary building well safe from lighting stroke

  11. A proposal of a three-dimensional CT measurement method of maxillofacial structure

    International Nuclear Information System (INIS)

    Tanaka, Ray; Hayashi, Takafumi

    2007-01-01

    Three-dimensional CT measurement is put in practice in order to grasp the pathological condition on diseases such as the temporomandibular joint disorder, maxillofacial anomaly, jaw deformity, or fracture which cause the morphologic changes of the maxillofacial bones. On the 3D measurement, the unique system that is obtained by volume rendering 3D images with a simultaneous reference of axial images combined with coronal and sagittal multi-planar reconstruction (MPR) images (we call this MPR referential method), is employed in order to define the measurement points. Our purpose in this report is to indicate the usefulness of this unique method by comparing with the common way to define the measurement points on only 3D reconstruction images without consulting of MPR images. Clinical CT data obtained from a male patient with skeletal malocclusion was used. Contiguous axial images were reconstructed at 4 times magnification, with a reconstruction interval of 0.5 mm, focused on the temporomandibular joint region in his left side. After these images were converted to Digital Imaging and Communications in Medicine (DICOM) format and sent to personal computer (PC), 3D reconstruction image was created using free 3D DICOM medical image viewer. The coordinates of 3 measurement points (the lateral and medial pole of the mandibular condyle, and the left foramen ovale) were defined with MPR images (MPR coordinates) as reference coordinates, and then the coordinates that were defined on only 3D reconstruction image without consulting to MPR images (3D coordinates) were compared to those of MPR coordinates. Three examiners were engaged independently 10 times for every measurement point. In our result, there was no correspondence between 3D coordinates and MPR coordinates, and contribution of 3D coordinates showed a variety in every measurement point and in every observer. We deemed that ''MPR referential method'' is useful to assess the location of the target point of anatomical

  12. North American natural gas outlook : does gas remain a fuel option for oil sands?

    International Nuclear Information System (INIS)

    George, R.R.

    2003-01-01

    This paper presents a North America natural gas outlook from Purvin and Gertz, an international energy consulting firm that has 30 years experience in providing strategic, commercial and technical advice to the petroleum industry. In particular, this presentation focuses on natural gas market fundamentals and how they may impact on oil sands development. It includes charts and graphs depicting NYMEX natural gas outlooks to July, 2009 and examines how supply will react to major changes in Canada's supply portfolio. It was noted that oil sands development is a driver for natural gas demand in Alberta. The existing regional gas pipeline infrastructure was presented and the market impact on upgrader options was discussed. The author suggests that if gas prices are too high, there are other fuel options for steam and power generation. These include bitumen, asphalt, coke, coal and nuclear. However, these options have additional costs, uncertainties and environmental issues. A key factor for success would be to have a clear understanding of the benefits and risks between these fuel options. 1 tab., 9 figs

  13. Walnut shells: replacement for natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Goss, J R; Williams, R O

    1977-11-01

    A method of extracting useful energy from cracked walnut shells has been developed by the University of California in co-operation with Diamond/Sunsweet, Inc., and the California Energy Resources Conservation and Development Commission. The technique involves converting the shells to producer gas, a low-Btu gas in which the major combustible components are carbon monoxide (20 to 30%) and hydrogen (10 to 15%).

  14. The future of gas power in Europe

    International Nuclear Information System (INIS)

    Trong, Maj Dang

    2001-01-01

    The growth of gas power capacity in Western Europe in 2001 is estimated at 6.5 per cent. The extent of plants under construction in 2001 and ambitious plans for further development demonstrates the general belief that investing in gas power is soon becoming profitable. Expected slump in the world economy may curb the willingness to invest, at least in the short run. In Norway, the greatest barrier to the development of gas power production is political. Great Britain is the major gas power producing country in Western Europe, contributing 30 per cent of the total production

  15. Comparative study of colorectal carcinoma examination with four postprocessing of CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Luo; Kangrong, Zhou [The 3rd Affilated Hospital Sun Yat-sen Univ. of Medical Sciences, Guangzhou (China). Dept. of Radiology

    2001-10-01

    Objective: To study the clinical value of colorectal carcinoma examination by comparison of different postprocessing techniques such as multiplanar reformation (MPR), CT virtual colonoscopy (CTVC), shaded surface display (SSD) and Raysum. Methods: 64 patients with colorectal carcinomas underwent volume scanning using spiral CT. MPR, CTVC, SSD and Raysum images were obtained by using 4 different software in workstation. All cases were proved by surgical or CC biotic histology. The results were compared and analyzed according to the circumferential extension, length and pathologic patterns of colorectal carcinoma with MPR, CTVC, SSD and Raysum. Results: The correction rate of determination the circumferential extension of colorectal carcinoma with MPR, CTVC, SSD and Raysum were 100.0%, 82.8%, 79.7% and 79.7%, respectively. There was significant statistical difference between MPR and CTVC; The accuracy of judging the length of carcinoma were 89.1%, 76.6%, 95.3% and 100.0%, respectively. There was statistical difference between CTVC and SSD; The accuracy of showing carcinoma pathologic patterns were 81.3%, 92.2%, 71.9% and 71.0%, respectively. There was statistical difference between CTVC and SSD, too. MPR could correctly determine the circumferential extension of colorectal carcinoma. In determination the length of carcinoma, Raysum was more accurate than SSD. CTVC could be more helpful in showing carcinoma pathologic patterns. Conclusion: There were advantages and disadvantages in colorectal carcinoma examination with MPR, CTVC, SSD and Raysum, and the combination could display colorectal carcinoma more completely and comprehensively.

  16. Comparative study of colorectal carcinoma examination with four postprocessing of CT colonography

    International Nuclear Information System (INIS)

    Luo Mingyue; Zhou Kangrong

    2001-01-01

    Objective: To study the clinical value of colorectal carcinoma examination by comparison of different postprocessing techniques such as multiplanar reformation (MPR), CT virtual colonoscopy (CTVC), shaded surface display (SSD) and Raysum. Methods: 64 patients with colorectal carcinomas underwent volume scanning using spiral CT. MPR, CTVC, SSD and Raysum images were obtained by using 4 different software in workstation. All cases were proved by surgical or CC biotic histology. The results were compared and analyzed according to the circumferential extension, length and pathologic patterns of colorectal carcinoma with MPR, CTVC, SSD and Raysum. Results: The correction rate of determination the circumferential extension of colorectal carcinoma with MPR, CTVC, SSD and Raysum were 100.0%, 82.8%, 79.7% and 79.7%, respectively. There was significant statistical difference between MPR and CTVC; The accuracy of judging the length of carcinoma were 89.1%, 76.6%, 95.3% and 100.0%, respectively. There was statistical difference between CTVC and SSD; The accuracy of showing carcinoma pathologic patterns were 81.3%, 92.2%, 71.9% and 71.0%, respectively. There was statistical difference between CTVC and SSD, too. MPR could correctly determine the circumferential extension of colorectal carcinoma. In determination the length of carcinoma, Raysum was more accurate than SSD. CTVC could be more helpful in showing carcinoma pathologic patterns. Conclusion: There were advantages and disadvantages in colorectal carcinoma examination with MPR, CTVC, SSD and Raysum, and the combination could display colorectal carcinoma more completely and comprehensively

  17. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  18. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    International Nuclear Information System (INIS)

    Abe, T.; Izumiyama, H.; Fujisawa, I.

    2002-01-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders

  19. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Abe, T.; Izumiyama, H. [Showa Univ. School of Medicine, Tokyo (Japan). Dept. of Neurosurgery; Fujisawa, I. [Kishiwada City Hospital, Kishiwada (Japan). Dept. of Radiology

    2002-11-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders.

  20. The emergent natural gas markets

    International Nuclear Information System (INIS)

    Dewert, F.; Meeder, J.

    1998-01-01

    A 30% increase of natural gas consumption worldwide is expected to occur since the year 2010. This development will concern countries located outside the traditional markets, in particular in central and eastern Europe, Asia, Africa and south America. This paper summarizes the talks given by the different representatives of these regions who explain the expected evolutions of the natural gas market in these areas: reserves, production, consumption, demand, competition with other energy sources, financial aspects.. (J.S.)

  1. Structuring spot, short and long term gas contracts

    International Nuclear Information System (INIS)

    Gretener, N.M.

    1996-01-01

    A review of the core clauses of the modern natural gas purchase and sales contracts, was presented. There exists a wide variety of terms which can be used by a seller and a buyer to customize such a contract to suit particular circumstances. On the basis of length of term, gas contracts may classified as spot contracts having a term of 30 days or less, short term contracts having a term of 30 days to one to two years, and long term contracts having terms greater than two years. The three key elements which are applicable to all gas sales contracts are the contract price, the seller's obligation to deliver, and the buyer's obligation to accept. Other provisions that may be included in any gas sales contract in addition to the basic three were reviewed, including market pricing, load factor incentive pricing, seasonal pricing, pipeline demand charges, market shares, and the seller's right to decontract

  2. Offshore gas comes ashore

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W J

    1968-12-21

    The equivalent of 25% of present energy consumption is supplied by natural gas, but there is still much more work to be accomplished. Only 3 yr ago, the names West Sole, Leman Bank, Indefatigable, and Hewett were only significant to the North Sea fisherman as the names of proved fishing grounds. Now they are household words to almost everyone in the gas industry, if not the population at large. The estimate of the recoverable reserves from these 4 fields is under continuous review but the current figure is of the order of 25 million Mcf, sufficient to maintain an average withdrawal rate of 2,300 Mcfd for 30 yr. On shore, work is at present in progress on the development of the Lockton gas field in N. Yorkshire which has now proved to be capable of supplying about 1,000 Mcfd. The processes used and the plant installed off shore and at a terminal for gas treating vary according to the composition of the gas and the design philosophy of the operator. A flow sheet for a typical operation is given.

  3. 30 CFR 57.5002 - Exposure monitoring.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Exposure monitoring. 57.5002 Section 57.5002 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... monitoring. Dust, gas, mist, and fume surveys shall be conducted as frequently as necessary to determine the...

  4. 30 CFR 256.82 - Environmental studies.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Environmental studies. 256.82 Section 256.82... OIL AND GAS IN THE OUTER CONTINENTAL SHELF Studies § 256.82 Environmental studies. (a) The Director... practicable, be designed to predict environmental impacts of pollutants introduced into the environments and...

  5. 30 CFR 281.27 - Annual rental.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Annual rental. 281.27 Section 281.27 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.27 Annual rental...

  6. Comparing the sensitivity of permafrost and marine gas hydrate to climate warming

    International Nuclear Information System (INIS)

    Taylor, A.E.; Dallimore, S.R.; Hyndman, R.D.; Wright, F.

    2005-01-01

    The sensitivity of Arctic subpermafrost gas hydrate at the Mallik borehole was compared to temperate marine gas hydrate located offshore southwestern Canada. In particular, a finite element geothermal model was used to determine the sensitivity to the end of the ice age, and contemporary climate warming of a 30 m thick methane hydrate layer lying at the base of a gas hydrate stability zone prior to 13.5 kiloannum (ka) before present (BP). It was suggested that the 30 m gas-hydrate-bearing layer would have disappeared by now, according to the thermal signal alone. However, the same gas-hydrate-bearing layer underlying permafrost would persist until at least 4 ka after present, even with contemporary climate warming. The longer time for subpermafrost gas hydrate comes from the thawing pore ice at the base of permafrost, at the expense of dissociation of the deeper gas hydrate. The dissociation of underlying gas hydrate from climate surface warming is buffered by the overlying permafrost

  7. Investigation on the conditions mitigating membrane fouling caused by TiO2 deposition in a membrane photocatalytic reactor (MPR) used for dye wastewater treatment

    International Nuclear Information System (INIS)

    Damodar, Rahul-Ashok; You, Sheng-Jie; Chiou, Guan-Wei

    2012-01-01

    Highlights: ► The charge differences between particle and membrane accelerate the intensity of fouling and binding of TiO 2 particles. ► Severe fouling at pH 5 and low fouling at pH ≥ 7 at all flux conditions. ► The presence of a very thin TiO 2 cake layer can alter the hydrophilicity of the membrane surface. ► The resistance offered by dense TiO 2 cake layer could dominate the hydrophilic effect of TiO 2 particles. - Abstract: In this study, the effects of MPR's operating conditions such as permeate flux, solution pH, and membrane hydrophobicity on separation characteristics and membrane fouling caused by TiO 2 deposition were investigated. The extent of fouling was measured in terms of TMP and tank turbidity variation. The results showed that, at mildly acidic conditions (pH ∼ 5), the turbidity within the tank decreased and the extent of turbidity drop increased with increasing flux for all the membranes. On the other hand, at pH ≥ 7, the turbidity remained constant at all flux and for all membranes tested. The fouling variation at different pH was closely linked with the surface charge (zeta potential) and hydrophilicity of both membrane and particles. It was observed that the charge differences between the particles and membranes accelerate the intensity of fouling and binding of TiO 2 particles on the membrane surface under different pH conditions. The presence of a very thin layer of TiO 2 can alter the hydrophilicity of the membranes and can slightly decrease the TMP (filtration resistance) of the fouled membranes. Besides, the resistance offered by the dense TiO 2 cake layer would dominate this hydrophilic effect of TiO 2 particles, and it may not alter the filtration resistance of the fouled membranes.

  8. The experiences of research reactor accident to safety improvement

    International Nuclear Information System (INIS)

    Wiranto, S.

    1999-01-01

    The safety of reactor operation is the main factor in order that the nuclear technology development program can be held according the expected target. Several experience with research reactor incidents must be learned and understood by the nuclear program personnel, especially for operators and supervisors of RSG-GA. Siwabessy. From the incident experience of research reactor in the world, which mentioned in the book 'Experience with research reactor incidents' by IAEA, 1995, was concluded that the main cause of research reactor accidents is understandless about the safety culture by the nuclear installation personnel. With learn, understand and compare between this experiences and the condition of RSG GA Siwabessy is expended the operators and supervisors more attention about the safety culture, so that RSG GA Siwabessy can be operated successfull, safely according the expected target

  9. Opportunities in the United States' gas processing industry

    International Nuclear Information System (INIS)

    Meyer, H.S.; Leppin, D.

    1997-01-01

    To keep up with the increasing amount of natural gas that will be required by the market and with the decreasing quality of the gas at the well-head, the gas processing industry must look to new technologies to stay competitive. The Gas Research Institute (GR); is managing a research, development, design and deployment program that is projected to save the industry US dollar 230 million/year in operating and capital costs from gas processing related activities in NGL extraction and recovery, dehydration, acid gas removal/sulfur recovery, and nitrogen rejection. Three technologies are addressed here. Multivariable Control (MVC) technology for predictive process control and optimization is installed or in design at fourteen facilities treating a combined total of over 30x10 9 normal cubic meter per year (BN m 3 /y) [1.1x10 12 standard cubic feet per year (Tcf/y)]. Simple pay backs are typically under 6 months. A new acid gas removal process based on n-formyl morpholine (NFM) is being field tested that offers 40-50% savings in operating costs and 15-30% savings in capital costs relative to a commercially available physical solvent. The GRI-MemCalc TM Computer Program for Membrane Separations and the GRI-Scavenger CalcBase TM Computer Program for Scavenging Technologies are screening tools that engineers can use to determine the best practice for treating their gas. (au) 19 refs

  10. The usefulness of multiplanar reconstruction images in preoperative t-staging of advanced gastric cancer

    International Nuclear Information System (INIS)

    Koo, Young Baek; Kim, Suk; Lee, Jun Woo; Kim, Soo Jin; Choo, Ki Seok; Lee, Tae Hong; Moon, Tae Yong; Lee, Suk Hong; Jeon, Tae Yong

    2004-01-01

    The purpose of this study was to evaluate the performance of multidetector-row CT (MDCT) in the preoperative T-staging of patients with advanced gastric cancer. A total of 65 patients with an established diagnosis of advanced gastric cancer (T2 or more) were evaluated with MDCT. The protocol of MDCT consisted of high-quality (HQ) mode helical scanning with a slice thickness of 2.5 mm. The axial CT images were reconstructed with a slice thickness of 5 mm. MPR images were reconstructed from the raw axial data with a slice thickness of 5 mm. A comparison between the standard axial and axial MPR images was performed by two radiologists with regard to the evaluation of the tumor location and T-stage. These findings were compared with the pathologic and surgical findings. T-staging of the advanced stomach cancer was correct in 89% (58/65) and 69% (45/65) of the MPR images and axial images, respectively. The MPR images improved the detection rate (5 lesions) of the tumors and increased the accuracy of the T-staging (13 lesions) in comparison with the axial images. The MPR images are of greater diagnostic value for the evaluation of omental seeding (5 lesions: axial images, 9 lesions: MPR images), tumor location and extension. Multiplanar reconstruction (MPR) images provide increased confidence in the location and T-staging of certain cases of advanced gastric cancer, such as those in locations where CT images are susceptible to be affected by the difficulties associated with partial volume averaging. In this study, the MPR images provided more precise information about the tumor location and T-staging than the standard axial images in the preoperative evaluation of advanced gastric cancer

  11. 30 CFR 56.5002 - Exposure monitoring.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Exposure monitoring. 56.5002 Section 56.5002 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Agents Air Quality § 56.5002 Exposure monitoring. Dust, gas, mist, and fume surveys shall be conducted as...

  12. 30 CFR 256.44 - Bids disqualified.

    Science.gov (United States)

    2010-07-01

    ... by law, regulation, lease or stipulation to lease shall not disqualify an otherwise qualified bid; or... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Bids disqualified. 256.44 Section 256.44... OIL AND GAS IN THE OUTER CONTINENTAL SHELF Issuance of Leases § 256.44 Bids disqualified. The...

  13. Modular plants with high power gas engines (1 to 30 MWe); Centrales modulaires a moteurs gaz de forte puissance (de 1 a 30 MWe)

    Energy Technology Data Exchange (ETDEWEB)

    Haushalter, J. [Wartsila (France)

    1997-12-31

    This paper is a series of transparencies about the high power gas engines manufactured by Waertsilae NSD Corporation company. The first par recalls the NO{sub x} and CO air pollution regulations worldwide, the German TA-Luft standards and the French 2910 by-law according to the engine type (2 and 4 stroke, dual-fuel, natural gas, LPG, others..) and to the type of pollutants (NO{sub x}, dusts, SO{sub 2}, CO, noise..). The second part presents the Waertsilae NSD Corporation concept of gas-fueled spark ignition engines (Otto cycle, emissions, performances, technology, fuel system, combustion optimization, fuel-air ratio regulation, pollution control equipment) and of the `pure energy` global concept of plants. (J.S.)

  14. The Micro Trench Gas Counter

    International Nuclear Information System (INIS)

    Schmitz, J.

    1991-07-01

    A novel design is presented for a gas avalanche chamber with micro-strip gas readout. While existing gaseous microstrip detectors (Micro-strip Gas Counters, Knife edge chambers) have a minimum anode pitch of the order of 100 μm, the pitch of the discussed Micro Trench Gas Counter goes down to 30-50 μm. This leads to a better position resolution and two track separation, and a higher radiation resistivity. Its efficiency and signal speed are expected to be the same as the Microstrip Gas Counter. The energy resolution of the device is expected to be equal to or better than 10 percent for the 55 Fe peak. Since the anode strip dimensions are larger than those in a MSGC, the device may be not as sensitive to discharges and mechanical damage. In this report production of the device is briefly described, and predictions on its operation are made based on electric field calculations and experience with the Microstrip Gas Counter. The authors restrict themselves to the application in High Energy Physics. (author). 10 refs.; 9 figs

  15. Biomass gasification hot gas cleanup for power generation

    Energy Technology Data Exchange (ETDEWEB)

    Wiant, B.C.; Bachovchin, D.M. [Westinghouse Electric Corp., Orlando, FL (United States); Carty, R.H.; Onischak, M. [Institute of Gas Technology, Chicago, IL (United States); Horazak, D.A. [Gilbert/Commonwealth, Reading, PA (United States); Ruel, R.H. [The Pacific International Center for High Technology Research, Honolulu, HI (United States)

    1993-12-31

    In support of the US Department of Energy`s Biomass Power Program, a Westinghouse Electric led team consisting of the Institute of Gas Technology (IGT), Gilbert/Commonwealth (G/C), and the Pacific International Center for High Technology Research (PICHTR), is conducting a 30 month research and development program. The program will provide validation of hot gas cleanup technology with a pressurized fluidized bed, air-blown, biomass gasifier for operation of a gas turbine. This paper discusses the gasification and hot gas cleanup processes, scope of work and approach, and the program`s status.

  16. Mackenzie Gas Project : gas resource and supply study

    International Nuclear Information System (INIS)

    Harris, D.G.; Braaten, K.M.

    2004-01-01

    A study was conducted to assess the future gas supply for the Mackenzie Gas Project. The economically recoverable gas resources and deliverability in the region were assessed in order to support construction of the Mackenzie Valley pipeline and the associated gathering system. This supply study was based on a 25 year timeframe for resource development. Production forecasts were also prepared for 50 years following the date of the study. Natural gas forecasts for the general area to be served by the proposed pipeline were also presented. This report includes an introduction to the final gas resource and supply study as well as the regional geology relating to discovered and undiscovered resources. The following regions were included in the study area: onshore Mackenzie Delta including the Niglintgak, Parsons Lake and Taglu anchor fields; central Mackenzie Valley region extending from the Mackenzie Delta south to 63 degrees latitude; northern portion of the Yukon Territory; and, portions of the offshore Mackenzie Delta region limited to a water depth of 30 metres. Forecasts and economic analyses were prepared for the following 3 scenarios: contingent onshore resources only; contingent and prospective onshore resources; and, contingent and prospective onshore and offshore resources. Sensitivity forecasts were prepared for a fully expanded pipeline capacity of 1.8 bcf/day with an equal capacity gathering system. In addition, the National Energy Board estimates of resources for the 3 anchor field were used in place of the operator's estimates. A geological review was included for the plays in the study area. 15 refs., 43 tabs., 38 figs

  17. Nitrogen versus helium: effects of the choice of the atomizing gas on the structures of Fe50Ni30Si10B10 and Fe32Ni36Ta7Si8B17 powders

    International Nuclear Information System (INIS)

    Zambon, A.

    2004-01-01

    Gas atomization can produce, besides a possible significant degree of undercooling, high cooling rates, whose extent depends on the size of the droplets, on their velocity with respect to the surrounding medium, on the thermo-physical properties of both the alloy and the gas, and of course on the operating conditions such as melt overheating and gas-to-metal flow ratio. In this respect it is well-known that the atomizing gas can play a significant role in determining both the powder size distribution and the kind and mix of phases which result from the solidification and cooling processes. The microstructures and solidification morphologies of powders obtained from nitrogen and helium sonic gas atomization of two iron-nickel base glass forming alloys, Fe 50 Ni 30 Si 10 B 10 and Fe 32 Ni 36 Ta 7 Si 8 B 17 , were investigated by means of light microscopy, X-ray diffraction (XRD) and differential thermal analysis (DTA). The Fe 32 Ni 36 Ta 7 Si 8 B 17 alloy exhibits a higher proneness to the development of amorphous phase than the Fe 50 Ni 30 Si 10 B 10 alloy, while the effect of the higher speed attainable by the stream of helium with respect to that of nitrogen, affords not only to obtain a larger amount of particles in the finer size ranges, but also to affect the relative amounts of phases within the different size fractions

  18. Environmental changes of the last 30,000 years in the gas hydrate area of Joetsu Basin, eastern margin of Japan Sea

    Energy Technology Data Exchange (ETDEWEB)

    Freire, A.F.M.; Sugai, T. [Tokyo Univ., Kashiwanoha Campus, Chiba (Japan). Dept. of Natural Environmental Studies; Takeuchi, E.; Nagasaka, A.; Hiruta, A.; Ishizaki, O.; Matsumoto, R. [Tokyo Univ., Hongo Campus, Bunkyo-ku, Tokyo (Japan). Dept. of Earth and Planetary Science

    2008-07-01

    The Japan Sea is a semi-isolated marginal sea with an average depth of 1350 metres and a maximum water depth of approximately 3700 metres in the northern basin. This paper presented a study that inferred the age and the nature of the environmental events of the last 30 thousand years using geochemical and sedimentary records from piston cores collected on the gas hydrates bearing-sediments of Joetsu Basin, eastern margin of Japan Sea, south of Sado Islands. Interbedded dark gray thinly laminates and dark brown to gray bioturbated units are common throughout the quaternary sediments of the Japan Sea. They have been explained in terms of glacio-eustatic sea-level change. Active methane venting and gas hydrates have also been recognized, which are widely distributed just beneath the sea floor in the Joetsu Basin, in the eastern margin of the Japan Sea. In order to identify the nature of the organic matter present in the study area and to make a correlation with samples collected in the Pacific Ocean, the study utilized total organic carbon contents and carbon isotopic composition of the gas hydrates bearing-sediments. Using X-ray diffraction analysis, these data were used to apply sequence stratigraphy concepts to locate the holocene/pleistocene boundary and to identify key stratigraphic surfaces, and also to recognize methane flux variations and sulfate-methane interfaces. The paper discussed total organic carbon in the Holocene/Pleistocene boundaries; nature of the organic matter and terrestrial versus marine phytoplankton production; and terrigenous material input. Sulfate oxidation of methane was also discussed. It was concluded that the correlation between the Japan Sea and Pacific Ocean was possible using piston cores. 13 refs., 13 figs.

  19. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C

    2016-01-01

    (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in endocardial-epicardial distribution of perfusion reserve may be demonstrated with static CT perfusion. Low MPR in all myocardial layers was observed specifically in obese patients....

  20. Gas microstrip detectors for X-ray tomographic flow imaging

    CERN Document Server

    Key, M J; Luggar, R D; Kundu, A

    2003-01-01

    A investigation into the suitability of gas microstrip detector technology for a high-speed industrial X-ray tomography system is reported. X-ray energies in the region 20-30 keV are well suited to the application, which involves imaging two-dimensional slices through gas/liquid multiphase pipeline flows for quantitative component fraction measurement. Stable operation over a period representing several hundred individual tomographic scans at gas gains of 500 is demonstrated using a Penning gas mixture of krypton/propylene.

  1. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo

    2010-01-01

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years ±10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07±0.62 ml min -1 g -1 , whereas stress MBF was 3.15±1.93 ml min -1 g -1 and the MPR was 3.33±1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, β=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, β=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  2. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo [Mie Univ., Graduate School of Medicine, Tsu, Mie (Japan)

    2010-11-15

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years {+-}10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07{+-}0.62 ml min{sup -1} g{sup -1}, whereas stress MBF was 3.15{+-}1.93 ml min{sup -1} g{sup -1} and the MPR was 3.33{+-}1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, {beta}=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, {beta}=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  3. In-Flame Characterization of a 30 MWth Bio-Dust Flame

    DEFF Research Database (Denmark)

    Johansen, Joakim Myung; Jensen, Peter Arendt; Clausen, Sønnik

    concentric low-NOx configuration. The measurements focus on a single 30 MWth flame and include: Quantification of the gas temperature, the gas phase composition: O2, CO, CO2, H2O, and light hydrocarbons by intrusive probe measurements. It also includes both seeded and unseeded 2D laser doppler anemometry...... of a full-scale burner and provide a comprehensive data set that quantifies key parameters: Gas phase temperature, composition, and flow field required in order to evaluate the performance of CFD simulations of complex combustion systems...

  4. Particle fuelling for long pulse with standard gas puff and supersonic pulsed gas injection

    International Nuclear Information System (INIS)

    Bucalossi, J.; Tsitrone, E.; Martin, G.

    2003-01-01

    In addition to the standard gas puff and to the technically complex pellet injection, a novel intermediate method, based on the injection of a supersonic high density cloud of neutrals, has been recently implemented on the Tore Supra tokamak. Fuelling efficiency, in the 30-50% range are found while it lies in the 10-20% range for the gas puff. It is not sensitive to the plasma density and to the additional heating. According to modelling, the increased efficiency is attributed to the very short injection duration compared to the particle confinement time and to the strong cooling of the plasma edge resulting from the massive injection of matter. A feedback loop on the frequency of the injector has been successfully implemented to control the plasma density. In long pulse experiments (>200s), wall saturation has not been reached. Gas puffing rate was typically around 1 Pa.m 3 s -1 while dynamic wall retention around 0.6 Pa.m 3 s -1 . Co-deposited carbon layer could trap such large amounts of gas. A discharge fuelled by supersonic pulsed gas injections exhibits lower wall retention than a gas puff fuelled discharge. (author)

  5. Hot gas cleanup test facility for gasification and pressurized combustion. Quarterly technical progress report, July 1--September 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-31

    The objective of this project is to evaluate hot gas particle control technologies using coal-derived gas streams. This will entail the design, construction, installation, and use of a flexible test facility which can operate under realistic gasification and combustion conditions. The major particulate control device issues to be addressed include the integration of the particulate control devices into coal utilization systems, on-line cleaning techniques, chemical and thermal degradation of components, fatigue or structural failures, blinding, collection efficiency as a function of particle size, and scale-up of particulate control systems to commercial size. The conceptual design of the facility was extended to include a within scope, phased expansion of the existing Hot Gas Cleanup Test Facility Cooperative Agreement to also address systems integration issues of hot particulate removal in advanced coal-based power generation systems. This expansion included the consideration of the following modules at the test facility in addition to the existing Transport Reactor gas source and Hot Gas Cleanup Units: Carbonizer/Pressurized Circulating Fluidized Bed Gas Source; hot Gas Cleanup Units to mate to all gas streams; and Combustion Gas Turbine. Fuel Cell and associated gas treatment. This expansion to the Hot Gas Cleanup Test Facility is herein referred to as the Power Systems Development Facility (PSDF).

  6. Environmental concerns and regulatory initiatives related to hydraulic fracturing in shale gas formations: potential implications for North American gas supply

    Energy Technology Data Exchange (ETDEWEB)

    Sumi, Lisa [Earthworks (Canada)

    2010-09-15

    Shale gas resources have been referred to as a game changer for North America and it is expected that shale gas will account for over 30% of the natural gas production in North America by 2020. However, the development of this resource has raised several concerns, notably in terms of water use and contamination; more stringent regulations could be implemented in the coming years. The aim of this paper is to present the effect that more stringent regulations would have on gas development in the Marcellus shale, which accounts for 20% of North American shale gas production. Information on hydraulic fracturing and its environmental impacts is provided herein, along with information on the regulatory initiatives underway in the Marcellus shale region. This paper pointed out that novel regulations relating to shale gas development could significantly reduce the growth in shale gas production.

  7. 30 CFR 250.602 - Equipment movement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Equipment movement. 250.602 Section 250.602... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Workover Operations § 250.602 Equipment movement. The movement of well-workover rigs and related equipment on and off a platform or from well to well on...

  8. 30 CFR 250.502 - Equipment movement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Equipment movement. 250.502 Section 250.502... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Completion Operations § 250.502 Equipment movement. The movement of well-completion rigs and related equipment on and off a platform or from well to well...

  9. 30 CFR 250.504 - Hydrogen sulfide.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Hydrogen sulfide. 250.504 Section 250.504... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Completion Operations § 250.504 Hydrogen sulfide. When a well-completion operation is conducted in zones known to contain hydrogen sulfide (H2S) or in...

  10. 30 CFR 250.604 - Hydrogen sulfide.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Hydrogen sulfide. 250.604 Section 250.604... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Workover Operations § 250.604 Hydrogen sulfide. When a well-workover operation is conducted in zones known to contain hydrogen sulfide (H2S) or in...

  11. The liberalization of gas markets in Europe

    International Nuclear Information System (INIS)

    Lecarpentier, A.

    2006-01-01

    On June 22, 1998 all EU Member States unanimously approved Directive 98/30/EC, the so-called Gas Directive, which paved the way for far-reaching changes in the European gas sector and for the establishment of an internal gas market. Five years have elapsed since it was transposed into national law and although markets have started to open up, their rate of progress varies. The next milestone in achieving a fully competitive European market is July 1, 2007, but there are still many obstacles to overcome. (author)

  12. The liberalization of gas market in Europe

    International Nuclear Information System (INIS)

    Lecarpentier, Armelle

    2006-01-01

    On June 22, 1998, all EU Member States unanimously approved Directive 98/30/EC, the so-called Gas Directive, which paved the way for far-reaching changes in the European gas Sector and for the establishment of an internal gas market. Five years have elapsed since it was transposed into national law and although markets have started to open up, their rate of progress varies. The next milestone in achieving a fully competitive European market is July 1, 2007, but there are still many obstacles to overcome [it

  13. High-repetition-rate short-pulse gas discharge.

    Science.gov (United States)

    Tulip, J; Seguin, H; Mace, P N

    1979-09-01

    A high-average-power short-pulse gas discharge is described. This consists of a volume-preionized transverse discharge of the type used in gas lasers driven by a Blumlein energy storage circuit. The Blumlein circuit is fabricated from coaxial cable, is pulse-charged from a high-repetition-rate Marx-bank generator, and is switched by a high-repetition-rate segmented rail gap. The operation of this discharge under conditions typical of rare-gas halide lasers is described. A maximum of 900 pps was obtained, giving a power flow into the discharge of 30 kW.

  14. Modeling of flowing gas diode pumped alkali lasers: dependence of the operation on the gas velocity and on the nature of the buffer gas.

    Science.gov (United States)

    Barmashenko, B D; Rosenwaks, S

    2012-09-01

    A simple, semi-analytical model of flowing gas diode pumped alkali lasers (DPALs) is presented. The model takes into account the rise of temperature in the lasing medium with increasing pump power, resulting in decreasing pump absorption and slope efficiency. The model predicts the dependence of power on the flow velocity in flowing gas DPALs and checks the effect of using a buffer gas with high molar heat capacity and large relaxation rate constant between the 2P3/2 and 2P1/2 fine-structure levels of the alkali atom. It is found that the power strongly increases with flow velocity and that by replacing, e.g., ethane by propane as a buffer gas the power may be further increased by up to 30%. Eight kilowatt is achievable for 20 kW pump at flow velocity of 20  m/s.

  15. Gas demand to rise in the Usa

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    Could US consumption of natural gas rise by as much as 13 quadrillion Btu (quads) over the next 20 years? A new study conducted for the American Gas Foundation by Washington Policy and Analysis says it's certainly a possibility if appropriate policies are implemented. 'Fueling the Future: Natural Gas and New Technologies for a Cleaner 21. Century', confirms what natural gas industry professionals have long suspected: changes in US energy policy that favor increased use of natural gas could improve air quality, conserve energy and reduce reliance on imported oil from politically unstable countries. Consequently, the study forecasts that the environmental, economic and efficiency advantages of natural gas-combined with advances in gas-related technologies and the introduction of new end-use technologies - could help push. US gas consumption into the 35-quad range over the next two decades. Currently, American gas demand is close to 22 quads a year. The study tracks two scenarios: a 'current projection', which shows gas demand reaching nearly 30 quads by 2020, and an 'accelerated projection', which foresees demand topping 35 quads by then based on the adoption of national policies encouraging greater use of natural gas. (authors)

  16. Low-Cost Resonant Cavity Raman Gas Probe for Multi-Gas Detection

    Science.gov (United States)

    Thorstensen, J.; Haugholt, K. H.; Ferber, A.; Bakke, K. A. H.; Tschudi, J.

    2014-12-01

    Raman based gas sensing can be attractive in several industrial applications, due to its multi-gas sensing capabilities and its ability to detect O_2 and N_2. In this article, we have built a Raman gas probe, based on low-cost components, which has shown an estimated detection limit of 0.5 % for 30 second measurements of N_2 and O_2. While this detection limit is higher than that of commercially available equipment, our estimated component cost is approximately one tenth of the price of commercially available equipment. The use of a resonant Fabry-Pérot cavity increases the scattered signal, and hence the sensitivity, by a factor of 50. The cavity is kept in resonance using a piezo-actuated mirror and a photodiode in a feedback loop. The system described in this article was made with minimum-cost components to demonstrate the low-cost principle. However, it is possible to decrease the detection limit using a higher-powered (but still low-cost) laser and improving the collection optics. By applying these improvements, the detection limit and estimated measurement precision will be sufficient for e.g. the monitoring of input gases in combustion processes, such as e.g. (bio-)gas power plants. In these processes, knowledge about gas compositions with 0.1 % (absolute) precision can help regulate and optimize process conditions. The system has the potential to provide a low-cost, industrial Raman sensor that is optimized for specific gas-detection applications.

  17. 30 CFR 250.1202 - Liquid hydrocarbon measurement.

    Science.gov (United States)

    2010-07-01

    ... FMPs; Inclusion of production from additional structures; Meter updates which add buy-back gas meters... the API MPMS as incorporated by reference in 30 CFR 250.198, when obtaining net standard volume and... manufacturer; (ii) Meters operate within the manufacturer's specifications for maximum and minimum flow rate...

  18. 40 CFR 1065.645 - Amount of water in an ideal gas.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Amount of water in an ideal gas. 1065... in an ideal gas. This section describes how to determine the amount of water in an ideal gas, which... of water in an ideal gas, x H20, as follows: ER30AP10.034 Where: x H20 = amount of water in an ideal...

  19. Scenarios for Russia's natural gas exports to 2050

    International Nuclear Information System (INIS)

    Paltsev, Sergey

    2014-01-01

    Russia is an important energy supplier as it holds the world's largest natural gas reserves and it is the world's largest exporter of natural gas. Despite a recent reduction in Russia's exports to Europe, it plans to build new pipelines. We explore the long-term (up to 2050) scenarios of Russian natural gas exports to Europe and Asia using the MIT Emissions Prediction and Policy Analysis (EPPA) model, a computable general equilibrium model of the world economy. We found that over the next 20–40 years natural gas can still play a substantial role in Russian exports and there are substantial reserves to support a development of the gas-oriented energy system both in Russia and in its current and potential gas importers. Based on the considered scenarios, Russia does not need any new pipeline capacity to the EU unless it wants to diversify its export routes to supply the EU without any gas transit via Ukraine and Belarus. Asian markets are attractive to Russian gas and substantial volumes may be exported there. Relatively cheap shale gas in China may sufficiently alter the prospects of Russian gas, especially in Asian markets. In the Reference scenario, exports of natural gas grow from Russia's current 7 Tcf to 11–12 Tcf in 2030 and 13–14 Tcf in 2050. Alternative scenarios provide a wider range of projections, with a share of Russian gas exports shipped to Asian markets rising to more than 30% by 2030 and almost 50% in 2050. Europe's reliance on LNG imports increases, while it still maintains sizable imports from Russia. - Highlights: • In the Reference scenario exports of natural gas grow from Russia’s current 7 Tcf to 11–12 Tcf in 2030 and 13–14 Tcf in 2050. • In alternative scenarios a share of Russian exports to Asian markets is rising to about 30% by 2030 and 50 % in 2050. • Cheap shale gas in China can sufficiently alter Russian natural gas export. • Reduction in nuclear generation in Europe can lead to increased exports of natural gas from

  20. 30 CFR 250.808 - Hydrogen sulfide.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Hydrogen sulfide. 250.808 Section 250.808... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Production Safety Systems § 250.808 Hydrogen sulfide. Production operations in zones known to contain hydrogen sulfide (H2S) or in zones where the presence of H2S...

  1. A versatile gas interface for routine radiocarbon analysis with a gas ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, L., E-mail: wacker@phys.ethz.ch [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Fahrni, S.M. [Department of Chemistry and Biochemistry, University of Bern, 3012 Berne (Switzerland); Oeschger Centre for Climate Change Research, University of Bern, 3012 Berne (Switzerland); Paul Scherrer Institute (PSI), 5232 Villigen (Switzerland); Hajdas, I. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Molnar, M. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Institute of Nuclear Research, Hungarian Academy of Sciences, 4026 Debrecen (Hungary); Synal, H.-A. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Szidat, S. [Department of Chemistry and Biochemistry, University of Bern, 3012 Berne (Switzerland); Oeschger Centre for Climate Change Research, University of Bern, 3012 Berne (Switzerland); Zhang, Y.L. [Department of Chemistry and Biochemistry, University of Bern, 3012 Berne (Switzerland); Oeschger Centre for Climate Change Research, University of Bern, 3012 Berne (Switzerland); Paul Scherrer Institute (PSI), 5232 Villigen (Switzerland)

    2013-01-15

    In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 {mu}g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO{sub 2} into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO{sub 2} can be provided in four different ways to the versatile gas interface. As a primary method, CO{sub 2} is delivered in glass or quartz ampoules. In this case, the CO{sub 2} is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO{sub 2} is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO{sub 2} is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given.

  2. Natural gas market assessment ten years after deregulation

    International Nuclear Information System (INIS)

    1996-11-01

    Changes which have taken place in the Canadian natural gas market in the ten years since the gas market was de-regulated, were reviewed. A 1985 agreement created conditions for a competitive natural gas market. However, the National Energy Board ensured that the pipeline transmission sector of the gas industry would continue to be regulated because of its natural monopoly characteristics. Open non-discriminatory access was to be provided to all shippers on inter-provincial gas pipelines. One objective of this report was to provide the Board with the means of assuring itself that the market was operating in such a way that Canadian requirements for natural gas were being met at fair market prices. The report also provided a review of the major changes in the gas producing and transmission sector, and reviewed developments in gas markets and sales practices. The overall assessment was that the natural gas industry was efficient and responsive to the demands of the marketplace. 5 tabs., 30 figs

  3. ConocoPhillips Gas Hydrate Production Test

    Energy Technology Data Exchange (ETDEWEB)

    Schoderbek, David [ConocoPhillips Co., Houston, TX (United States); Farrell, Helen [ConocoPhillips Co., Houston, TX (United States); Howard, James [ConocoPhillips Co., Houston, TX (United States); Raterman, Kevin [ConocoPhillips Co., Houston, TX (United States); Silpngarmlert, Suntichai [ConocoPhillips Co., Houston, TX (United States); Martin, Kenneth [ConocoPhillips Co., Houston, TX (United States); Smith, Bruce [ConocoPhillips Co., Houston, TX (United States); Klein, Perry [ConocoPhillips Co., Houston, TX (United States)

    2013-06-30

    Work began on the ConocoPhillips Gas Hydrates Production Test (DOE award number DE-NT0006553) on October 1, 2008. This final report summarizes the entire project from January 1, 2011 to June 30, 2013.

  4. Gas measurements from the Costa Rica-Nicaragua volcanic segment suggest possible along-arc variations in volcanic gas chemistry

    Science.gov (United States)

    Aiuppa, A.; Robidoux, P.; Tamburello, G.; Conde, V.; Galle, B.; Avard, G.; Bagnato, E.; De Moor, J. M.; Martínez, M.; Muñóz, A.

    2014-12-01

    Obtaining accurate estimates of the CO2 output from arc volcanism requires a precise understanding of the potential along-arc variations in volcanic gas chemistry, and ultimately of the magmatic gas signature of each individual arc segment. In an attempt to more fully constrain the magmatic gas signature of the Central America Volcanic Arc (CAVA), we present here the results of a volcanic gas survey performed during March and April 2013 at five degassing volcanoes within the Costa Rica-Nicaragua volcanic segment (CNVS). Observations of the volcanic gas plume made with a multicomponent gas analyzer system (Multi-GAS) have allowed characterization of the CO2/SO2-ratio signature of the plumes at Poás (0.30±0.06, mean ± SD), Rincón de la Vieja (27.0±15.3), and Turrialba (2.2±0.8) in Costa Rica, and at Telica (3.0±0.9) and San Cristóbal (4.2±1.3) in Nicaragua (all ratios on molar basis). By scaling these plume compositions to simultaneously measured SO2 fluxes, we estimate that the CO2 outputs at CNVS volcanoes range from low (25.5±11.0 tons/day at Poás) to moderate (918 to 1270 tons/day at Turrialba). These results add a new information to the still fragmentary volcanic CO2 output data set, and allow estimating the total CO2 output from the CNVS at 2835±1364 tons/day. Our novel results, with previously available information about gas emissions in Central America, are suggestive of distinct volcanic gas CO2/ST (= SO2 + H2S)-ratio signature for magmatic volatiles in Nicaragua (∼3) relative to Costa Rica (∼0.5-1.0). We also provide additional evidence for the earlier theory relating the CO2-richer signature of Nicaragua volcanism to increased contributions from slab-derived fluids, relative to more-MORB-like volcanism in Costa Rica. The sizeable along-arc variations in magmatic gas chemistry that the present study has suggested indicate that additional gas observations are urgently needed to more-precisely confine the volcanic CO2 from the CAVA, and from

  5. Isotopologues of dense gas tracers in NGC 1068

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Junzhi; Qiu, Jianjie [Shanghai Astronomical Observatory, Chinese Academy of Sciences, 80 Nandan Road, 200030, Shanghai (China); Zhang, Zhi-Yu [Institute for Astronomy, University of Edinburgh, Royal Observatory, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom); Shi, Yong [School of Astronomy and Space Science, Nanjing University, Nanjing, 210093 (China); Zhang, Jiangshui [Center For Astrophysics, GuangZhou University, 510006, GuangZhou (China); Fang, Min, E-mail: jzwang@shao.ac.cn [ESO, Karl Schwarzschild Strasse 2, D-85748 Garching bei Munich (Germany)

    2014-11-20

    We present observations of isotopic lines of dense gas tracers toward the nuclear region of nearby Seyfert 2 galaxy NGC 1068 with the IRAM 30 m telescope and the Atacama Pathfinder Experiment (APEX) 12 m telescope. We detected four isotopic lines (H{sup 13}CN 1-0, H{sup 13}CO{sup +} 1-0, HN{sup 13}C 1-0, and HC{sup 18}O{sup +} 1-0) at the 3 mm band with the IRAM 30 m telescope and obtained upper limits of other lines. We calculated optical depths of dense gas tracers with the detected isotopic lines of HCN 1-0, HCO{sup +} 1-0, and HNC 1-0. We find that the {sup 14}N/{sup 15}N abundance ratio is greater than 420 if we adopt the upper limit of HC{sup 15}N(1-0) emission. Combining this with fluxes of 1-0 lines from IRAM 30 m observations and the upper limit of 3-2 lines from APEX 12 m observations, we also estimated the excitation condition of molecular gas in the nuclear region of NGC 1068, which is less dense than that in the extreme starburst regions of galaxies.

  6. The evaluation of stress and piping support loads on RSG-GAS secondary cooling system

    International Nuclear Information System (INIS)

    Pustandyo, W.; Sitandung, Y. B.; Sujalmo, S.

    1998-01-01

    The evaluation of stress and piping support loads was evaluated on piping segment of secondary cooling water piping. In this paper, the analysis methods are presented with the use of computer code PS + CAEPIPE Version 3. 4. 05. W. From the selected pipe segment, the data of pipe characteristic, material properties, operation and design condition, equipment and support were used as inputs. The result of analysis show that stress and support loads if using location, kind and number of support equal with the system that have been installed for sustain load 3638 psi (node 160), thermal 13517 psi (node 90) and combination of sustain and thermal (node 90) 16747 psi. Meanwhile,if the optimization support, stress and support load for sustain load are respectively 4238 psi (node 10), thermal 13517 psi (node 90) and combination of sustain + thermal (node 90) 17350 psi. The limit values of permitted support based on Code PS+CAEPIPE of sustain load are 15000 psi, thermal 22500 psi and combination of sustain + thermal 37500 psi. The conclusion of evaluation result, that stress support load of pipe secondary cooling system are sufficiently low and using support show excessive and not economic

  7. Reactivity And Neutron Flux At Silicide Fuel Element In The Core Of RSG-GAS

    International Nuclear Information System (INIS)

    Hamzah, Amir

    2000-01-01

    In order to 4.8 and 5.2 gr U/cm exp 3 loading of U 3 Si 2 --Al fuel plates characterization, he core reactivity change and neutron flux depression had been done. Control rod calibration method was used to reactivity change measurement and neutron flux distribution was measured using foil activation method. Measurement of insertion of A-type of testing fuel element with U-loading above cannot be done due to technical reason, so the measurement using full type silicide fuel element of 2.96 gr U/cm exp 3 loading. The reactivity change measurement result of insertion in A-9 and C-3 is + 2.67 cent. The flux depression at silicide fuel in A-9 is 1.69 times bigger than oxide and in C-3 is 0.68 times lower than oxide

  8. Gas density fluctuations in the Perseus Cluster: clumping factor and velocity power spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Zhuravleva, I.; Churazov, E.; Arevalo, P.; Schekochihin, A. A.; Allen, S. W.; Fabian, A. C.; Forman, W. R.; Sanders, J. S.; Simionescu, A.; Sunyaev, R.; Vikhlinin, A.; Werner, N.

    2015-05-20

    X-ray surface brightness fluctuations in the core of the Perseus Cluster are analysed, using deep observations with the Chandra observatory. The amplitude of gas density fluctuations on different scales is measured in a set of radial annuli. It varies from 7 to 12 per cent on scales of ~10–30 kpc within radii of 30–220 kpc from the cluster centre. Using a statistical linear relation between the observed amplitude of density fluctuations and predicted velocity, the characteristic velocity of gas motions on each scale is calculated. The typical amplitudes of the velocity outside the central 30 kpc region are 90–140 km s-1 on ~20–30 kpc scales and 70–100 km s-1 on smaller scales ~7–10 kpc. The velocity power spectrum (PS) is consistent with cascade of turbulence and its slope is in a broad agreement with the slope for canonical Kolmogorov turbulence. The gas clumping factor estimated from the PS of the density fluctuations is lower than 7–8 per cent for radii ~30–220 kpc from the centre, leading to a density bias of less than 3–4 per cent in the cluster core. Uncertainties of the analysis are examined and discussed. Future measurements of the gas velocities with the Astro-H, Athena and Smart-X observatories will directly measure the gas density–velocity perturbation relation and further reduce systematic uncertainties in this analysis.

  9. Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images

    International Nuclear Information System (INIS)

    Duc, Sylvain R.; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments. (orig.)

  10. CARBON DIOXIDE - PARTIAL PRESSURE (pCO2) - SEA and Other Data from MULTIPLE SHIPS From TOGA Area - Pacific (30 N to 30 S) from 19890101 to 19891231 (NODC Accession 9500075)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Sea/air gas ratios data was collected in TOGA Area - Pacific (30 N to 30 S) between January 1, 1989 and December 31, 1989 during cruises conducted using ships...

  11. 30 CFR 250.457 - What equipment is required to monitor drilling fluids?

    Science.gov (United States)

    2010-07-01

    ... monitor the drilling fluid returns. The indicator may be located in the drilling fluid-logging compartment... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What equipment is required to monitor drilling... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations...

  12. Calibration of CIR processes to CVA data and applications to estimation of Market Price of Risk

    DEFF Research Database (Denmark)

    Hvolby, Thomas; Christensen, Bent Jesper; Høg, Esben

    2018-01-01

    We present a rigorous framework for CDS valuation and calibration to market quotes on single-name CDSs and methods of calculating the market price of risk (MPR) on such markets. We use the results of MPR for bond markets, and thus the MPR corresponds to the survival probabilities, which is a non......-tradable asset. Further, we present a set-up for numerical valuation of triparty CDS agreements, where two default risky parties trade a CDS with a third entity as reference credit....

  13. Gas-cooled fast reactor program. Progress report, January 1, 1980-June 30, 1981

    International Nuclear Information System (INIS)

    Kasten, P.R.

    1981-09-01

    Since the national Gas-Cooled Fast Breeder Reactor Program has been terminated, this document is the last progress report until reinstatement. It is divided into three sections: Core Flow Test Loop, GCFR shielding and physics, and GCFR pressure vessel and closure studies

  14. Continuous lenalidomide treatment for newly diagnosed multiple myeloma

    DEFF Research Database (Denmark)

    Palumbo, Antonio; Hajek, Roman; Delforge, Michel

    2012-01-01

    Lenalidomide has tumoricidal and immunomodulatory activity against multiple myeloma. This double-blind, multicenter, randomized study compared melphalan-prednisone-lenalidomide induction followed by lenalidomide maintenance (MPR-R) with melphalan-prednisone-lenalidomide (MPR) or melphalan-prednis...

  15. Production of MO-99 from LEU targets - Acid-side processing

    International Nuclear Information System (INIS)

    Conner, C.; Sedlet, J.; Wiencek, T.C.

    2000-01-01

    During 2000, additional targets of the new annular design containing low enriched uranium (LEU) foils were irradiated in the Indonesian RSG-GAS reactor. This new design significantly decreases the target fabrication cost. This irradiation allowed us to compare the irradiation performance of several batches of LEU foil. We also processed one of the irradiated foils to recover 99 Mo using a slightly modified Cintichem process. Finally, we measured some important physical properties of uranyl nitrate solutions (i.e., density and solubility), which will be useful in future efforts to further increase the amount of uranium that can be processed by the Cintichem process. (author)

  16. 30 CFR 206.172 - How do I value gas produced from leases in an index zone?

    Science.gov (United States)

    2010-07-01

    ... gas production that is not sold under an arm's-length dedicated contract is the index-based value... safety net prices calculated at § 206.172(e)(4)(i) exceeds the index-based value that applies to the gas... contract is the higher of the index-based value under paragraph (d) of this section or the value of that...

  17. Towards the future french organization of the natural gas industry

    International Nuclear Information System (INIS)

    2001-01-01

    In the framework of the new directive on the internal gas market of 1998, the government proposed a discussion by the presentation of this white book, providing information and questions. This book proposes seven main chapters: the gas industry activity and the directive on the internal gas market; the gas actors, the key numbers and the juridical context in France; define and strengthen the natural gas public utility; useful actions for each gas facilities (transport, distribution, storage and retailers); the realization of progresses for the consumer; the operating of an efficiency control; actions to develop the gas operators in the world. The text of the 98/30/CE directive is also provided. (A.L.B.)

  18. Natural gas: a rose by any other name

    International Nuclear Information System (INIS)

    Smorskarski, G.

    1999-01-01

    Natural gas is expected to provide 30% of the European Union's energy demand by 2020 as compared with 20% in 1995. Although price is still used as a selling point for gas, its increasing popularity and market share are assisted by its image. It is perceived as both 'clean' and 'modern' and indeed its environmental credentials are good compared with those of oil and coal. A gigajoule of energy generated using oil or gas produces 53% or 83% more carbon dioxide, respectively, than using natural gas because of the combustion efficiency of the methane molecule. The significance of the adjective 'natural' as an added marketing advantage is discussed. (UK)

  19. The liberalization of the European gas market and its consequences for Russia

    International Nuclear Information System (INIS)

    Finon, D.; Locatelli, C.

    2002-01-01

    Russia is the world biggest natural gas producer, with output of 581 bn m 3 in 2001, and is also a key supplier of the European gas market (around 30% of current European Union gas imports). Therefore gas exports rank with oil exports as an essential variable of Russian economic policy, and any institutional evolution of its gas export markets is crucial for Russia's economy as well as its gas industry. Liberalization of the European gas market will have major consequences for main suppliers, and therefore for Russia. (author)

  20. The liberalization of the European gas market and its consequences for Russia

    Energy Technology Data Exchange (ETDEWEB)

    Finon, D.; Locatelli, C

    2002-07-01

    Russia is the world biggest natural gas producer, with output of 581 bn m{sup 3} in 2001, and is also a key supplier of the European gas market (around 30% of current European Union gas imports). Therefore gas exports rank with oil exports as an essential variable of Russian economic policy, and any institutional evolution of its gas export markets is crucial for Russia's economy as well as its gas industry. Liberalization of the European gas market will have major consequences for main suppliers, and therefore for Russia. (author)

  1. New directions in gas processing

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    Papers presented at the Insight conference held on January 30, 1996 in Calgary, Alberta, were contained in this volume. The conference was devoted to a discussion of new directions in the gas processing business, the changing business environment, new processing technologies, and means by which current facilities agreements can be adapted to the new commercial reality. High operating costs which have resulted in the downsizing and restructuring of the industry, and partnering with a third party in the gathering and processing operations, with apparently beneficial result both to plant owners, as well to third party processors, received the most attention. The relationship between the gas processor and the gas producer as they relate to the Petroleum Joint Venture Association (PJVA) Gas Processing Agreement, which defines the obligations of third parties, was the center of discussion. Regulatory changes and the industry's response to the changes was also on the agenda. Refs., tabs., figs

  2. Ziff Energy Group's 3. annual 2001+ gas industry outlook

    International Nuclear Information System (INIS)

    2001-04-01

    A survey was conducted in April 2001 regarding industry expectations of gas prices, supply, markets, and transportation. The survey involved 97 participants ranging from gas producers, end-users, marketers, pipeline and local distribution companies in North America. The results of the survey can be summarized as follows: Natural gas prices are expected to grow and remain above oil prices through at least 2002. There will continue to be strong growth prospects for North American gas supply, but North American gas storage will be tight for the winter of 2001. North American gas demand is expected to continue to grow. Participants in the survey remained confident that gas demand would continue to grow, despite higher gas prices. Competition from alternative fuels in electricity generation did not appear to be an area of concern for the participants of the survey. 30 figs

  3. Growth of a Massive Young Stellar Object Fed by a Gas Flow from a Companion Gas Clump

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xi; Shen, Zhiqiang [Shanghai Astronomical Observatories, Chinese Academy of Science, Nandan Rd. 80, Shanghai (China); Ren, Zhiyuan [National Astronomical Observatories, Chinese Academy of Science, Chaoyang District Datun Rd. A20, Beijing (China); Zhang, Qizhou [Harvard-Smithsonian Center for Astrophysics, 60 Garden St, Cambridge, MA 02138 (United States); Qiu, Keping [School of Astronomy and Space Science, Nanjing University, 22 Hankou Rd., Nanjing, Jiangsu 210093 (China)

    2017-02-01

    We present a Submillimeter Array (SMA) observation toward the young massive double-core system G350.69-0.49. This system consists of a northeast (NE) diffuse gas bubble and a southwest (SW) massive young stellar object (MYSO), both clearly seen in the Spitzer images. The SMA observations reveal a gas flow between the NE bubble and the SW MYSO in a broad velocity range from 5 to 30 km s{sup −1} with respect to the system velocity. The gas flow is well confined within the interval between the two objects and traces a significant mass transfer from the NE gas bubble to the SW massive core. The transfer flow can supply the material accreted onto the SW MYSO at a rate of 4.2×10{sup −4} M{sub ⊙} yr{sup −1}. The whole system therefore suggests a mode for the mass growth in the MYSO from a gas transfer flow launched from its companion gas clump, despite the driving mechanism of the transfer flow not being fully determined from the current data.

  4. Intercalibration of in vivo counting systems using an Asian phantom results of a co-ordinated research project 1996-1998

    CERN Document Server

    International Atomic Energ Agency. Vienna

    2003-01-01

    Radioactive materials are used in many industries, and, whenever unsealed radioactive sources are present, intakes of radionuclides by workers can occur. Adequate radiation protection of workers is an essential requirement for the safe and acceptable use of radiation, radioactive materials and nuclear energy. Guidance on the application of the requirements of the International Basis Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) to occupational protection is given in three interrelated Safety Guides: Occupational Radiation Protection (RS-G-1.1); Assessment of Occupational Exposure due to Intakes of Radionuclides (RS-G-1.2); Assessment of Occupational Exposure due to External Sources of Radiation (RS-G-1.3) published in 1999 and further guidance is given in Safety Reports. Uranium, thorium and transuranic elements such as plutonium and americium are encountered throughout the nuclear fuel cycle and in industry. Radionuclides of these elements have a sig...

  5. Progenitors of low-luminosity Type II-Plateau supernovae

    Science.gov (United States)

    Lisakov, Sergey M.; Dessart, Luc; Hillier, D. John; Waldman, Roni; Livne, Eli

    2018-01-01

    The progenitors of low-luminosity Type II-Plateau supernovae (SNe II-P) are believed to be red supergiant (RSG) stars, but there is much disparity in the literature concerning their mass at core collapse and therefore on the main sequence. Here, we model the SN radiation arising from the low-energy explosion of RSG stars of 12, 25 and 27 M⊙ on the main sequence and formed through single star evolution. Despite the narrow range in ejecta kinetic energy (2.5-4.2 × 1050 erg) in our model set, the SN observables from our three models are significantly distinct, reflecting the differences in progenitor structure (e.g. surface radius, H-rich envelope mass and He-core mass). Our higher mass RSG stars give rise to Type II SNe that tend to have bluer colours at early times, a shorter photospheric phase, and a faster declining V-band light curve (LC) more typical of Type II-linear SNe, in conflict with the LC plateau observed for low-luminosity SNe II. The complete fallback of the CO core in the low-energy explosions of our high-mass RSG stars prevents the ejection of any 56Ni (nor any core O or Si), in contrast to low-luminosity SNe II-P, which eject at least 0.001 M⊙ of 56Ni. In contrast to observations, Type II SN models from higher mass RSGs tend to show an H α absorption that remains broad at late times (due to a larger velocity at the base of the H-rich envelope). In agreement with the analyses of pre-explosion photometry, we conclude that low-luminosity SNe II-P likely arise from low-mass rather than high-mass RSG stars.

  6. Molecular and Ionized Hydrogen in 30 Doradus. I. Imaging Observations

    Science.gov (United States)

    Yeh, Sherry C. C.; Seaquist, Ernest R.; Matzner, Christopher D.; Pellegrini, Eric W.

    2015-07-01

    We present the first fully calibrated H2 1-0 S(1) image of the entire 30 Doradus nebula. The observations were conducted using the NOAO Extremely Wide-field Infrared Imager (NEWFIRM) on the CTIO 4 m Blanco Telescope. Together with a NEWFIRM Brγ image of 30 Doradus, our data reveal the morphologies of the warm molecular gas and ionized gas in 30 Doradus. The brightest H2-emitting area, which extends from the northeast to the southwest of R136, is a photodissociation region (PDR) viewed face-on, while many clumps and pillar features located at the outer shells of 30 Doradus are PDRs viewed edge-on. Based on the morphologies of H2, Brγ, CO, and 8 μm emission, the H2 to Brγ line ratio, and Cloudy models, we find that the H2 emission is formed inside the PDRs of 30 Doradus, 2-3 pc to the ionization front of the H ii region, in a relatively low-density environment <104 cm-3. Comparisons with Brγ, 8 μm, and CO emission indicate that H2 emission is due to fluorescence, and provide no evidence for shock excited emission of this line.

  7. MOLECULAR AND IONIZED HYDROGEN IN 30 DORADUS. I. IMAGING OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Sherry C. C. [Subaru Telescope, National Astronomical Observatory of Japan, 650 North A’ohoku Place, Hilo, HI 96720 (United States); Seaquist, Ernest R.; Matzner, Christopher D. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Pellegrini, Eric W., E-mail: yeh@naoj.org [Department of Physics and Astronomy, University of Toledo, 2801 West Bancroft Street, Toledo, OH 43606 (United States)

    2015-07-10

    We present the first fully calibrated H{sub 2} 1–0 S(1) image of the entire 30 Doradus nebula. The observations were conducted using the NOAO Extremely Wide-field Infrared Imager (NEWFIRM) on the CTIO 4 m Blanco Telescope. Together with a NEWFIRM Brγ image of 30 Doradus, our data reveal the morphologies of the warm molecular gas and ionized gas in 30 Doradus. The brightest H{sub 2}-emitting area, which extends from the northeast to the southwest of R136, is a photodissociation region (PDR) viewed face-on, while many clumps and pillar features located at the outer shells of 30 Doradus are PDRs viewed edge-on. Based on the morphologies of H{sub 2}, Brγ, CO, and 8 μm emission, the H{sub 2} to Brγ line ratio, and Cloudy models, we find that the H{sub 2} emission is formed inside the PDRs of 30 Doradus, 2–3 pc to the ionization front of the H ii region, in a relatively low-density environment <10{sup 4} cm{sup −3}. Comparisons with Brγ, 8 μm, and CO emission indicate that H{sub 2} emission is due to fluorescence, and provide no evidence for shock excited emission of this line.

  8. 30 CFR 281.8 - Rights to minerals.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Rights to minerals. 281.8 Section 281.8 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF General § 281.8 Rights to minerals. (a) Unless...

  9. Natural Gas Liberalisation and Deregulation - The German Gas Industry's View

    International Nuclear Information System (INIS)

    Czernie, W.

    2001-01-01

    In Europe, the process of creating a single energy market is under way. The 1998 Gas Directive established an important date for the European gas industry. On 10 August 1998, ''Directive 98/30/EC of the European Parliament and of the Council of 22 June 1998 concerning common rules for the internal market in natural gas'' came into force. It had to be transposed into national law by the EU member states within two years, i.e. by 10 August 2000. The Directive is a cornerstone in establishing a competitive gas market in the European Union. It is the outcome of several years of negotiations and can be regarded as a compromise between the various interests. On the whole, it leaves EU member states with sufficient scope for adequately taking account of national characteristics in keeping with the principle of subsidiarity. The process of transposing the Gas Directive into the national law of individual EU member states is being closely followed by the European Commission. While acknowledging all the progress made in the single market process, the Commission still detects shortcomings in the implementation of the Gas Directive on the road to an actual single market. This is seen as a justification for new initiatives and intervention, even though the new political framework for the gas industry has not yet been tested in practice and been able to prove itself on a broad scale for any length of time. In the debate on liberalisation, tried-and-tested instruments of secure and market-oriented gas supply on the European continent long-term supply contracts with take-or-pay clauses and competitive oil-indexed gas prices have also come under scrutiny. However, even under the conditions of liberalisation, security of supply has to be achieved mainly by a balanced mix of supply sources and by long-term supply contracts, including competitive pricing as ensured by so-called oil indexing. In the further liberalisation of west European gas industries, it will be essential to ensure

  10. The eligibility of the natural gas consumers

    International Nuclear Information System (INIS)

    2004-07-01

    The eligible consumers are allowed to chose freely their natural gas producers and negotiate the prices and the supply modalities. In this context this information paper presents the legislative and regulation framework of the natural gas consumers eligibility, a definition of the possible eligible consumers and a list at the 30 january 2004. It provides also recommendations and answers to the more often asked questions on the administrative procedures and the contracts. (A.L.B.)

  11. Magnetophonon resonance in multimode lattices and two-dimensional structures (DQW)

    Science.gov (United States)

    Ploch, D.; Sheregii, E.; Marchewka, M.; Tomaka, G.

    2007-12-01

    The experimental results obtained for the magneto-transport in the InGaAs/InAlAs double quantum wells (DQW) structures of two different shapes of wells are reported. The Magnetophonon Resonance (MPR) o was observed for both types of the structures at 77-125K temperatures in the pulsed magnetic field. Four kinds of LO-phonons are taken into account to interpret the MPR oscillations in DQW. The particularity of MPR in DQW is the great number Landau levels caused by SAS-splitting all electron states.

  12. Magnetophonon resonance in multimode lattices and two-dimensional structures (DQW)

    Energy Technology Data Exchange (ETDEWEB)

    Ploch, D; Sheregii, E; Marchewka, M; Tomaka, G [Institute of Physics University of Rzeszow, 35-310 Rzeszow, Rejtana 16 (Poland)

    2007-12-15

    The experimental results obtained for the magneto-transport in the InGaAs/InAlAs double quantum wells (DQW) structures of two different shapes of wells are reported. The Magnetophonon Resonance (MPR) o was observed for both types of the structures at 77-125K temperatures in the pulsed magnetic field. Four kinds of LO-phonons are taken into account to interpret the MPR oscillations in DQW. The particularity of MPR in DQW is the great number Landau levels caused by SAS-splitting all electron states.

  13. Action of coal gas on plants. II. Action on green plants

    Energy Technology Data Exchange (ETDEWEB)

    Wehmer, C

    1917-01-01

    Experiments were performed to determine the effects of coal gas on cress. Although the seeds are not killed by coal gas, they are prevented from germinating. Cress will grow in as much as 30% coal gas, but it will not survive higher concentrations. Coal gas contains both toxic and non-toxic constituents. CO, C/sub 2/H/sub 4/, C/sub 2/H/sub 2/, CS/sub 2/, H/sub 2/S are not toxic at concentrations found in coal gas. The toxic effects of coal gas are not caused by the lack of O/sub 2/, but by minor impurities in the gas.

  14. 75 FR 3232 - Northern Natural Gas Company; Notice of Request Under Blanket Authorization

    Science.gov (United States)

    2010-01-20

    ... Natural Gas Company; Notice of Request Under Blanket Authorization January 8, 2010. Take notice that on December 30, 2009, Northern Natural Gas Company (Northern), 1111 South 103rd Street, Omaha, Nebraska 68124...'s regulations under the Natural Gas Act for authorization to increase its maximum storage capacity...

  15. Modular plants with high power gas engines (1 to 30 MWe); Centrales modulaires a moteurs gaz de forte puissance (de 1 a 30 MWe)

    Energy Technology Data Exchange (ETDEWEB)

    Haushalter, J. [Wartsila NSD (France)

    1997-12-31

    After a review of pollution regulations in France and Europe for high capacity combustion plants, the Wartsila NSD spark ignition combustion system, using natural gas, is presented: the air-gas mixture in the combustion chamber is very weak (lambda is around 2-2.2) and its ignition is completed by the flame exiting the pre-chamber containing a stoichiometric mixture, and the spark plug. The temperature is decreased thus lowering the NOx emission level. The combustion system is integrated in the Pure Energy global concept (cogeneration plants, etc.) from Wartsila

  16. 30 CFR 256.50 - Dating of leases.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Dating of leases. 256.50 Section 256.50 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF SULPHUR OR OIL AND GAS IN THE OUTER CONTINENTAL SHELF Issuance of Leases § 256.50 Dating of leases. All leases issued under...

  17. Design and performance of BWC replacement steam generators for PWR systems

    Energy Technology Data Exchange (ETDEWEB)

    Klarner, R.; Steinmoeller, F.; Millman, J.; Schneider, W. [Babcock and Wilcox Canada, Cambridge, Ontario (Canada)

    1998-07-01

    In recent years, Babcock and Wilcox Canada (BWC) has provided a number of PWR Replacement Steam Generators (RSGS) to replace units that had experienced extensive Alloy 600 tube degradation. BWC RSG units are in operation at Northeast Utilities' Millstone Unit 2, Rochester Gas and Electric's Ginna Station, Duke Energy's Catawba Unit 1, McGuire Unit 1 and 2, Florida Power and Light's St. Lucie Unit 1 and Commonwealth Edison's Byron 1 Station. Extensive start-up performance characteristics have been obtained for Millstone 2, Ginna, McGuire 1, and Catawba 1 RSGS. The Millstone 2, Ginna and Catawba 1 RSGs have also undergone extensive inspections following their first cycle of operation. The design and start-up performance characteristics of these RSGs are presented. The BWC Replacement Steam generators were designed to fit the existing envelope of pressure boundary dimensions to ensure licensability and integration into the Nuclear Steam Supply System. The RSGs were provided with a tube bundle of Alloy 690TT tubing, sized to match or exceed the original steam generator (OSG) thermal performance including provision for the reduced thermal conductivity of Alloy 690 relative to Alloy 600. The RSG tube bundle configurations provide a higher circulation design relative to the OSG, and feature corrosion resistant lattice grid and U-bend tube supports which provide effective anti-vibration support. The tube bundle supports accommodate relatively unobstructed flow and allow unrestrained structural interactions during thermal transients. Efficient steam separators assure low moisture carryover as well as high circulation. Performance measurements obtained during start-up verify that the BWC RSGs meet or exceed the specified thermal and moisture carryover performance requirements. RSG water level stability results at nor-mal operation and during plant transients have been excellent. Visual and ECT inspections have confirmed minimal deposition and 100

  18. Removal of 14C from nitrogen annulus gas

    International Nuclear Information System (INIS)

    Cheh, C.H.

    1985-01-01

    A dry, ambient temperature process using Ca(OH) 2 as the sorbent to remove 14 CO 2 from moderator cover gas was further developed to remove 14 C from the extremely dry nitrogen annulus gas. Thermal gravimetric analysis was carried out to study the thermal stability of Ca(OH) 2 and the CO 2 -Ca(OH) 2 reaction at elevated temperatures under extremely low humidity conditions. Results shows that to achieve high utilization and avoid decomposition of Ca(OH) 2 , humidification of the annulus gas was necessary at high or low temperatures. Results of the bench scale (1-10 L/min) oxidizer study showed that, with 0.5% Pd or alumina as the catalyst, it was possible to achieve complete oxidation of CO and over 80% oxidation of CH 4 with 1% hydrogen in the nitrogen. The gas superficial velocity should be less than or equal to30 cm/s and the residence time greater than or equal to0.5 s. A pilot scale (up to 160 L/min) system including a catalytic oxidizer, a humidifier/demister, a Ca(OH) 2 reactor, a condenser/demister and regenerable molecular sieve dryers, was assembled and tested with simulated nitrogen annulus gas. Results showed that complete oxidation of the CO and 60-100% oxidation of the CH 4 with 0.5% H 2 in the simulated gas were achieved in the pilot plant. The CO 2 concentration was reduced from 30-60 μL/L at the inlet of the Ca(OH) 2 reactor to 1 μL/L or less at the outlet. After modifications of the dryer to overcome the problems encountered, the simulated annulus gas was dried to 0 C dew point before recirculation. Equipment specifications and operating conditions of a 14 C removal system for nitrogen annulus gas are summarized

  19. Thesis: the ''evolutions of the long term European gas market - organisation and costs''

    International Nuclear Information System (INIS)

    Ouvry, V.

    1998-01-01

    This paper presents the main conclusions of the thesis defended by the author on January 30, 1998: recalls of some characteristics of the European gas market, the stakes of the gas market liberation, the regulatory aspects, the tariffs problem, the competition in the gas marketing segment, and different possible modeling of the gas market evolution (contracts, costs, competition). (J.S.)

  20. Determination of short half-life elements in biological, foodstuff, and environmental samples qualitatively by neutron activation analysis

    International Nuclear Information System (INIS)

    Syukria Kurniawati; Muhayatun Santoso; Diah Dwiana Lestiani

    2010-01-01

    NAA applications at routine operation power of 15 MW at Multipurpose Reactor GA Siwabessy (MPR-GAS) for sample matrices analysis have been widely applied. However, the results are not optimum for some matrices especially for short half-live elements. Preliminary study of short half-life elements determination in biological, foodstuff, and environmental samples using 1 MW power have been conducted to solve this problem. The samples were irradiated in rabbit system of MPR-GAS for 5 minutes, counted for 200 seconds by HPGe detector, and the spectrum were analyzed further using software Genie 2000 and Bandung NAA Utility. Analysis under 1 MW power on biological and foodstuff samples were capable to detect eight elements: Al, Br, CI, Ca, I, K, Mg, Ti, and Na for biological samples; Al, Br, CI, Ca, I, K, Mg, Mn, and Na for foodstuff samples, while at 15 MW power only three elements (CI, K, Na) were detected. At 1 MW power the counting process is more optimum due to smaller radiation exposure and dead time. For the environmental samples, the number of elements detected by 1 MW and 15 MW powers did not differ significantly. Generally, the results on the three types of samples showed that the elements of short half-life are better detected at 1 MW than that of 15 MW power. Further research needs to be done to obtain the optimum analytical conditions for irradiation and counting time determination. (author)

  1. North Africa oil and gas

    International Nuclear Information System (INIS)

    Priddle, R.

    1996-01-01

    During the last decade, Algeria, Egypt and Libya have improved their fiscal terms for oil and gas development to attract more investment in this area. As a group, the three countries are implementing plans to increase crude oil production capacity 16 % from 3.15 million barrels per day (Mb/d) in 1995 to 3.65 Mb/d in the year 2000. Natural gas liquid are also being developed and their production capacity is planned to increase 30 % to 0.82 Mb/d in 2000. Concurrently, natural gas production capacity is being expanded about 50 % by 200 and natural gas exporting capacity should see a 92 % increase in 2000 over 1995 levels in short, the North Africa hydrocarbon producers are rapidly expanding their production and export capacity of gaseous and liquid hydrocarbons. This is the first IEA study to focus on North Africa. It shows how changing hydrocarbon legislation or production sharing agreements can result in changes in crude oil and natural gas production capacity. Much of the expansion outlined in this study is being guided by international oil companies attracted by the improved fiscal terms

  2. Polymeric Gas-Separation Membranes for Petroleum Refining

    Directory of Open Access Journals (Sweden)

    Yousef Alqaheem

    2017-01-01

    Full Text Available Polymeric gas-separation membranes were commercialized 30 years ago. The interest on these systems is increasing because of the simplicity of concept and low-energy consumption. In the refinery, gas separation is needed in many processes such as natural gas treatment, carbon dioxide capture, hydrogen purification, and hydrocarbons separations. In these processes, the membranes have proven to be a potential candidate to replace the current conventional methods of amine scrubbing, pressure swing adsorption, and cryogenic distillation. In this paper, applications of polymeric membranes in the refinery are discussed by reviewing current materials and commercialized units. Economical evaluation of these membranes in comparison to traditional processes is also indicated.

  3. Electricity and natural gas retail markets - Observatory 3. Quarter 2017 (Figures as at 30/09/2017)

    International Nuclear Information System (INIS)

    2017-01-01

    The retail markets Observatory aims to provide general monitoring indicators of electricity and natural gas retail markets in France. This Observatory is updated on a Quarterly basis and published on CRE's web site (www.cre.fr). The first part of the report summarises the highlights of the electricity market (situation, market shares, suppliers, sales, dynamic analysis, regulated prices). The natural gas market is detailed in the second part

  4. Electricity and natural gas retail markets - Observatory 3. Quarter 2016 (Figures as at 30/09/2016)

    International Nuclear Information System (INIS)

    2016-01-01

    The retail markets Observatory aims to provide general monitoring indicators of electricity and natural gas retail markets in France. This Observatory is updated on a Quarterly basis and published on CRE's web site (www.cre.fr). The first part of the report summarises the highlights of the electricity market (situation, market shares, suppliers, sales, dynamic analysis, regulated prices). The natural gas market is detailed in the second part

  5. Electricity and natural gas retail markets - Observatory 2. Quarter 2016 (Figures as at 30/06/2016)

    International Nuclear Information System (INIS)

    2016-01-01

    The retail markets Observatory aims to provide general monitoring indicators of electricity and natural gas retail markets in France. This Observatory is updated on a Quarterly basis and published on CRE's web site (www.cre.fr). The first part of the report summarises the highlights of the electricity market (situation, market shares, suppliers, sales, dynamic analysis, regulated prices). The natural gas market is detailed in the second part

  6. Electricity and natural gas retail markets - Observatory 2. Quarter 2017 (Figures as at 30/06/2017)

    International Nuclear Information System (INIS)

    2017-01-01

    The retail markets Observatory aims to provide general monitoring indicators of electricity and natural gas retail markets in France. This Observatory is updated on a Quarterly basis and published on CRE's web site (www.cre.fr). The first part of the report summarises the highlights of the electricity market (situation, market shares, suppliers, sales, dynamic analysis, regulated prices). The natural gas market is detailed in the second part

  7. The capacity increase of the Bolivia-Brasil Gas Pipeline to 30 MMm{sup 3} diameter. Relative aspects to the enterprise; O aumento de capacidade do gasoduto Bolivia-Brasil para 30 MMm{sup 3}/dia nominal. Aspectos relativos ao empreendimento

    Energy Technology Data Exchange (ETDEWEB)

    D' Oliveira, Celso Araripe; Igreja, Carlos Alexandre Fanjul [PETROBRAS, Rio de Janeiro, RJ (Brazil); Claussen, Edgard Soares; Castro, Raymundo Cesar de Mello Araujo [Transportadora Brasileira Gasoduto Bolivia-Brasil, S.A., Rio de Janeiro, RJ (Brazil)

    2005-07-01

    GASBOL - Gasoduto Bolivia - Brasil Gas Pipeline had its natural gas transport capacity increased from 17 MMm3/day to 30 MMm3/day, in the period of November 1999 - May 2003, with the bidding, engineering design, procurement, construction, commissioning, start-up, tests, assisted operation and acceptance of 8 (eight) compression stations (ECOMP's), equipped with 02 (two) groups of solar compressors and turbines-MHI, 15000 HP, each. This paper presents aspects relative to that Project, including the characterization / description of the pipeline and the compression plants, the EPC type contract, the several construction phases and, the management aspects of costs and schedule. In addition, a historic of the main facts will be presented, including, the problems and the solutions adopted in the technical and management areas. The main positive and negative aspects will also be presented. These aspects have been discussed in a workshop with the participation of the Engineering Service of PETROBRAS and TBG. Finally, we will present the conclusions and recommendations learned with the experience of this Project, in order to give feedback for new Projects. (author)

  8. Gas condensate--raw material for producing liquid paraffin hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Aliyeva, R.B.; Alikishi-Zade, G.Yu.; Kuliyev, A.M.; Leonidov, A.N.; Pereverzev, A.N.

    1980-01-01

    The problem of efficient utilization of gas condensates as raw material for removal of a valuable product, liquid paraffins, is examined. A classification of gas condensates is given which is used as raw material for removing these hydrocarbons: gas condensate with high content of n-alkanes (25-40 mass percent), with average content (18-25 mass percent), with low content (12-18 mass percent), light weight fractions compositions, which do not contain fractions up to 200/sup 0/, and also, content ofless than 12% n-alkanes. Gas condensate I-III groups are 30% of the total reserve of gas condensate. Liquid paraffins hydrocarbons, produced from fractions of diesel fuel, which has been removed from Shatlyk gas condensate under conditions which simulate virtual processes of caramide deparaffinization meet all requirements without additional refining.

  9. The construction of a microstrip gas tracker for Hermes

    International Nuclear Information System (INIS)

    Brand, J. van den

    1994-01-01

    To measure the spin structure of the nucleon, the HERMES experiment is planned at the HERA electron beam using a polarised internal gas target. A tracker is being built to reconstruct the vertex of the exciting particles. It consists of two drift chambers and two microstrip gas counter (MSGC) systems. The MSGC systems are housed into two gas gatight containers surrounding the beam pipe and located immediately after the exit flange of the target housing. The active area of the upper MSGC system covers an angular range of 40 mrad≤θ v ≤ 140 mrad by -170 mrad≤θ h ≤170 mrad. Below the beam pipe a second system is situated with the same acceptance. Each track within the acceptance is measured by two stations of three MSCGs having a strip orientation, of 0 , and +30 and -30 respectively with respect to the vertical axis. (HSI)

  10. 30 CFR 281.33 - Bonds and bonding requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Bonds and bonding requirements. 281.33 Section 281.33 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.33...

  11. Immediate assessment of in situ gas content using underground manometric desorbometer

    Energy Technology Data Exchange (ETDEWEB)

    Lunaezewski, L.W.; Mahoney, M.R. [Lunagas Pty. Ltd., Newcastle, NSW (Australia)

    1995-12-31

    An underground assessment of gas content (within 30 minutes) can be used as a complementary method for the immediate establishment of the magnitudes of in situ gas content at a distance of 5 to 6 metres ahead of a heading face. The indirect method of in situ gas content measurement, using a manometric desorbometer, can be used to establish the direct relationship between underground desorbometer readings and corresponding in situ gas content values for a selected coal seam. 3 refs., 3 figs.

  12. An emerging economic view of world natural gas demand and supply

    International Nuclear Information System (INIS)

    Dorsett, W.H.; Ackerman, G.B.

    1992-01-01

    Natural gas is swiftly moving from a locally traded commodity in regional markets to a globally traded commodity. This paper describes a numerical model of international gas trade which evaluates the effects of inter- and intra-regional gas trade on demand, supply and price. Preliminary evidence indicates natural gas prices are 15 to 30% lower in real terms when inter-regional trade occurs and local consumption of natural gas increases relative to fuel oil in the local market. Natural gas developers or marketers that explicitly consider the inter-regional impacts of gas trade will have a greater likelihood of understanding the risks in marginal projects and are more likely to embrace economic projects and eschew noneconomic projects

  13. 13N-Ammonia pet-derived ventricular synchrony correlates with myocardial perfusion reserve better than left ventricular ejection fraction : A study in infarcted patients

    NARCIS (Netherlands)

    Juarez-Orozco, Luis Eduardo; Slart, Riemer; Tio, Rene A.; Inarra-Talboy, Fernando; Monroy, Andrea; Ayala-German, AnaGabriela; Dierckx, Rudi A.; Rosas, Erick Alexanderson

    2016-01-01

    Background: PET myocardial perfusion allows myocardial perfusion reserve (MPR) quantification as well as left ventricular ejection fraction (LVEF) and synchrony estimation through phase analysis. There is a relationship between MPR and LVEF and both have proven prognostic value in coronary artery

  14. The evolution of red supergiants to supernovae

    Science.gov (United States)

    Beasor, Emma R.; Davies, Ben

    2017-11-01

    With red supergiants (RSGs) predicted to end their lives as Type IIP core collapse supernova (CCSN), their behaviour before explosion needs to be fully understood. Mass loss rates govern RSG evolution towards SN and have strong implications on the appearance of the resulting explosion. To study how the mass-loss rates change with the evolution of the star, we have measured the amount of circumstellar material around 19 RSGs in a coeval cluster. Our study has shown that mass loss rates ramp up throughout the lifetime of an RSG, with more evolved stars having mass loss rates a factor of 40 higher than early stage RSGs. Interestingly, we have also found evidence for an increase in circumstellar extinction throughout the RSG lifetime, meaning the most evolved stars are most severely affected. We find that, were the most evolved RSGs in NGC2100 to go SN, this extra extinction would cause the progenitor's initial mass to be underestimated by up to 9M⊙.

  15. Fiscal 1999 report on basic research for promotion of joint implementation programs. Gas pipeline system optimization involving Ukrainian pipeline modification for reduction in global warming gas emissions; 1999 nendo ondanka gas haishutsu sakugen no tame no Ukraina ni okeru gas pipeline no kaishu wo fukumu pipeline system no saitekika chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The result of a survey which involves a 520km-long gas pipeline (Shebelinka-Dikanka-Kyiv) modification in the Ukraine is described, which will promote joint implementation programs under COP3 (Third Session of the Conference of the Parties to the United Nations Framework Convention on Climate Change). Since the greenhouse effect of methane gas is 21 times as serious as that of CO2, it is important to ensure good maintenance and structural soundness for natural gas transporting pipeline systems. The currently available Ukrainian gas turbines and compressors are so obsolescent that their efficiency rate is as low as 23%. The rate will rise to 36% when the old ones are replaced by high power equipment capable of high efficiency combustion. Pipelines will be checked for deterioration due to stress corrosion cracking and dangerous pipes will be replaced, with attention paid particularly to joint sections. It is expected that there will be a greenhouse gas reduction of 512,000 tons (in terms of CO2) and a saving of 103,000 tons on fuel (in terms of crude). Balance is tentatively estimated in case the expected reduction in emissions is transacted in emission trading. Profitability will occur, in view of profit from emission trading and gas sales revenue after gas leakage prevention thanks to project implementation, when the emission right sells at 30 dollars/ton or higher. The rippling effect will be great now that the Ukrainian pipeline system is quite extensive (with 30% thereof superannuated). (NEDO)

  16. Papers of the Ziff Energy Group's 30. North American gas strategies conference : setting the stage : energy policy to market

    International Nuclear Information System (INIS)

    2005-01-01

    Policies and economic drivers concerning the natural gas industry were the focus of this conference, which was divided into 3 sessions. The first session examined various policy issues and perspectives from government officials in North America. High energy prices and regulations concerning land access were reviewed, as well as supply costs and infrastructure needs. Outlooks for the natural gas industry in Alberta and British Columbia were presented. Issues concerning coalbed methane (CBM) and accessing off-shore natural gas were discussed. Activities in the Yukon were outlined. Land claim settlements were reviewed, and the development of a liquefied natural gas (LNG) infrastructure in Mexico was examined. Issues concerning the role of the natural gas industry in oil sands developments were addressed, as well as pipelines challenges and gas price impacts. Session 2 examined pipeline developments and infrastructure needs. Issues concerning stress corrosion cracking and the increase in Canadian pipelines were reviewed along with rates of return and market needs. Challenges facing natural gas infrastructure in the northeast were outlined and the impacts of LNG and northern supply were evaluated. Session 3 examined the impact of high gas prices. Macroeconomic impacts to the United States economy were discussed, as well as the impact of rising natural gas prices on the industrial sector. Issues concerning contract terms, credit terms, traded volumes and hedging were examined. Advances in temperature forecasting were reviewed. Short term price impacts and fundamental supply and demand issues were reviewed in relation to marketplace needs. Eleven presentations were given at this conference, of which 5 have been catalogued separately for inclusion in this database. tabs., figs

  17. Improving the gas productivity of the alkaline electrolyzer through the circulation technique

    Directory of Open Access Journals (Sweden)

    Kitipong Tangphant

    2014-03-01

    Full Text Available This research aims to study and improve the efficiency of a KOH electrolyzer through the gas productivity of the electrolyzer with different the circulation technique. In this work, the conceptual design of an electrolyzer falls into 2 categories; without pumping and with pumping. Direct current electricity at 5 different levels of 10, 15, 20, 25 and 30 A are charged into the system and the gas flow rate generated from the electrolyzer is subsequently monitored. The results show that at 30 A the gas generated from the circulation with pumping and the circulation without pumping are 2.31 litre/min and 1.76 litre/min, respectively. It is also found that the energy consumed by both techniques is the same; however, the circulation with pumping design shows the better gas productivity than that of the circulation without pumping design.

  18. 75 FR 27772 - Corning Natural Gas Corporation; Notice of Compliance Filing

    Science.gov (United States)

    2010-05-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-30-002] Corning Natural Gas Corporation; Notice of Compliance Filing May 11, 2010. Take notice that on May 3, 2010, Corning Natural Gas Corporation, (Corning) filed its Statement of section 311 Operating Conditions in compliance...

  19. Varying gas quality - Gas supply in Sweden 2011 and onwards; Varierande gaskvalitet - Gasfoersoerjning i Sverige 2011och framaat

    Energy Technology Data Exchange (ETDEWEB)

    Nelsson, Corfitz

    2011-10-15

    Since fall 2010 limited volumes of gas are imported from Germany to Denmark, which also reaches Sweden, but only between 10-30 % of the total volume of gas in winter. The gas which is imported from Germany has a composition that differs slightly from the Danish North Sea gas which has consequences for Swedish gas distributors and customers. The report highlights various possible consequences and how these are managed primarily in Denmark. One can conclude that for the time being, there is limited import capacity between Denmark and Germany, but work is underway to strengthen the capacity and within five years there is a possibility that by import support large parts of Sweden and Denmark, where necessary. In the current situation one can normally expect between 10-40 % imported gas in the gas that reach Sweden, which means a relatively limited impact on Swedish customers. In the current situation one can normally expect between 10-40 % import gas in the gas that reaches Sweden, which means a relatively limited impact on Swedish customers. If a number of different events coincides may temporarily the impact be high, but this is considered less likely in the short term. There are still a number of issues that need to be investigated further claims alleged, taxes and fees as well as billing and discounting.

  20. Natural gas in Norway - Possibilities and limitations

    International Nuclear Information System (INIS)

    Bjoerstad, H.; Eldegard, T.; Reve, T.; Sunnevaag, K.; Aarrestad, J.

    1995-06-01

    Norway is rich in gas resources. In recent years, gas sales from the Norwegian continental shelf have been in the order of 25 to 30 billion Sm 3 /yr and are expected to increase strongly the next 10 to 15 years. However, a scattered population, a difficult topography, long distances between large potential consumers and where the gas is brought ashore, make it difficult to utilize the gas commercially in this country. Moreover, the gas will have to compete with a highly developed hydro-electric network. This report evaluates possibilities and hindrances in the establishment of a home market for natural gas in Norway. The low population density implies that using gas for preheating of water, heating of rooms etc will not become important except, perhaps, locally, where gas may be available for other reasons. As a source of energy and raw material in many industrial processes, natural gas can become important in some coastal areas and in central parts of eastern Norway. Discussions are in progress on gas power stations for electricity production. This has aroused some controversy because of environmental problems, and for political acceptance gas power will have to replace coal power. As a fuel, gas may be of interest for domestic ferries and for busses. A lack of capital under financial risk and gas prices limit the market development. Although tax policy is presently favourable to gas power, the risk taken by private investors in converting to natural gas is increased by their not knowing for how long the gas will be exempt from environmental tax. 74 refs., 8 figs., 27 tabs

  1. Structuring spot, short and long term gas contracts; CD-ROM ed.

    Energy Technology Data Exchange (ETDEWEB)

    Gretener, N.M.

    1996-05-01

    A review of the core clauses of the modern natural gas purchase and sales contracts, was presented. There exists a wide variety of terms which can be used by a seller and a buyer to customize such a contract to suit particular circumstances. On the basis of length of term, gas contracts may classified as spot contracts having a term of 30 days or less, short term contracts having a term of 30 days to one to two years, and long term contracts having terms greater than two years. The three key elements which are applicable to all gas sales contracts are the contract price, the seller`s obligation to deliver, and the buyer`s obligation to accept. Other provisions that may be included in any gas sales contract in addition to the basic three were reviewed, including market pricing, load factor incentive pricing, seasonal pricing, pipeline demand charges, market shares, and the seller`s right to decontract.

  2. Studi Eksperimen Unjuk Kerja Mesin Diesel Menggunakan Sistem Dual Fuel Solar Gas CNG Dengan Variasi Tekanan Injeksi Gas Dan Derajat Waktu Injeksi

    Directory of Open Access Journals (Sweden)

    Dicky Yoko Exoryanto

    2017-01-01

    Full Text Available Bahan bakar gas ini jika ditinjau dari ekonomis tergolong sangat murah dan ramah lingkungan. Namun, pengaplikasian bahan bakar gas CNG pada generator diesel dengan sistem dual fuel berdampak pada penurunan performansinya. Hal ini terjadi karena rasio campuran udara dan bahan bakar pada sistem dual fuel belum sesuai, sehingga perlunya penelitian lebih lanjut. Penelitian ini bertujuan untuk meningkatkan performa pada mesin diesel dengan memodifikasi saluran masuk udara dengan memasang injector gas CNG untuk memasukkan bahan bakar tersebut kedalam ruang bakar sehingga mesin diesel berubah menjadi sitem dual fuel. Tidak hanya saluran masuk udara saja yang di modifikasi tetapi, variasi start of injection dan tekanan gas yang masuk juga di variasikan. Penelitian ini di lakukan secara eksperimental dengan menginjeksikan gas CNG ke dalam ruang bakar melalui saluran hisap yang sudah terpasang injector. Proses pengaturan injeksi gas CNG diatur oleh ECU programamble melalui software VEMSTUNE. Sistem pengaturan yang dilakukan adalah mengatur derajat waktu injection (SOI dengan nilai 5o, 30o, 55o, dan 80o CA BTDC dan variasi tekanan masuk gas CNG dengan nilai 1, 1,5, 2, dan 2,5 N/m2. Penelitian ini dilakukan dengan putaran mesin konstan sebesar 2000 rpm dengan beban 0 sampai 100 %. Hasil yang didapatkan dari eksperimen yang dilakukan kali ini, antara lain : performa dual fuel lebih optimal dibandingkan saat pengoperasian single fuel. Pengaturan paling optimal terjadi pada start of injection 80° CA BTDC dengan tekanan 1,5 gas CNG. Gas CNG dapat menggantikan porsi bahan bakar minyak solar sebesar 45,30 %. Nilai subtitusi minyak solar yang optimal sebesar 61,39 % dan SFC minyak solar rata-rata mengalami penurunan sebesar 47,10 %, tetapi SFC dual fuel rata-rata meningkat sebesar 47,67 % dibandingkan SFC single fuel. Nilai rata-rata efisiensi thermal turun sebesar 40,89 %, nilai AFR rata-rata turun dari 25,60 menjadi 12,90 dan Temperatur gas buang meningkat dari

  3. Analysis of gas turbine cogeneration plants in Italy; Indagine sulla funzionalita` degli impianti di cogenerazione conturbina a gas operanti in Italia

    Energy Technology Data Exchange (ETDEWEB)

    Romani, Rino; Vignati, Sigfrido [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Energia

    1997-10-01

    The purpose of this study is to improve, by random analysis, the current knowledge about functional and running data of gas turbine cogeneration plants in Italy. The analysis consider simple and combined cycle gas turbines plant with electric power less 30.000 k W per unit and involves a sample of 44 units according to a randomized model consisting of 112 gas turbines. The collected data show different plant selection criteria, energy performances, reliability and availability values as well as maintenance costs. These data support some general suggestions and recommendations for a better selection and utilization of these plants.

  4. High methane emissions dominate annual greenhouse gas balances 30 years after bog rewetting

    Science.gov (United States)

    Vanselow-Algan, M.; Schmidt, S. R.; Greven, M.; Fiencke, C.; Kutzbach, L.; Pfeiffer, E.-M.

    2015-02-01

    Natural peatlands are important carbon sinks and sources of methane (CH4). In contrast, drained peatlands turn from a carbon sink to a carbon source and potentially emit nitrous oxide (N2O). Rewetting of peatlands thus implies climate change mitigation. However, data about the time span that is needed for the re-establishment of the carbon sink function by restoration is scarce. We therefore investigated the annual greenhouse gas (GHG) balances of three differently vegetated bog sites 30 years after rewetting. All three vegetation communities turned out to be sources of carbon dioxide (CO2) ranging between 0.6 ± 1.43 t CO2 ha-2 yr-1 (Sphagnum-dominated vegetation) and 3.09 ± 3.86 t CO2 ha-2 yr-1 (vegetation dominated by heath). While accounting for the different global warming potential (GWP) of the three greenhouse gases, the annual GHG balance was calculated. Emissions ranged between 25 and 53 t CO2-eq ha-1 yr-1 and were dominated by large emissions of CH4 (22 up to 51 t CO2-eq ha-1 yr-1), while highest rates were found at purple moor grass (Molinia caerulea) stands. These are to our knowledge the highest CH4 emissions so far reported for bog ecosystems in temperate Europe. As the restored area was subject to large fluctuations in water table, we conclude that the high CH4 emission rates were caused by a combination of both the temporal inundation of the easily decomposable plant litter of this grass species and the plant-mediated transport through its tissues. In addition, as a result of the land use history, the mixed soil material can serve as an explanation. With regards to the long time span passed since rewetting, we note that the initial increase in CH4 emissions due to rewetting as described in the literature is not limited to a short-term period.

  5. High methane emissions dominated annual greenhouse gas balances 30 years after bog rewetting

    Science.gov (United States)

    Vanselow-Algan, M.; Schmidt, S. R.; Greven, M.; Fiencke, C.; Kutzbach, L.; Pfeiffer, E.-M.

    2015-07-01

    Natural peatlands are important carbon sinks and sources of methane (CH4). In contrast, drained peatlands turn from a carbon sink to a carbon source and potentially emit nitrous oxide (N2O). Rewetting of peatlands thus potentially implies climate change mitigation. However, data about the time span that is needed for the re-establishment of the carbon sink function by restoration are scarce. We therefore investigated the annual greenhouse gas (GHG) balances of three differently vegetated sites of a bog ecosystem 30 years after rewetting. All three vegetation communities turned out to be sources of carbon dioxide (CO2) ranging between 0.6 ± 1.43 t CO2 ha-2 yr-1 (Sphagnum-dominated vegetation) and 3.09 ± 3.86 t CO2 ha-2 yr-1 (vegetation dominated by heath). While accounting for the different global warming potential (GWP) of CO2, CH4 and N2O, the annual GHG balance was calculated. Emissions ranged between 25 and 53 t CO2-eq ha-1 yr-1 and were dominated by large emissions of CH4 (22-51 t CO2-eq ha-1 yr-1), with highest rates found at purple moor grass (Molinia caerulea) stands. These are to our knowledge the highest CH4 emissions so far reported for bog ecosystems in temperate Europe. As the restored area was subject to large fluctuations in the water table, we assume that the high CH4 emission rates were caused by a combination of both the temporal inundation of the easily decomposable plant litter of purple moor grass and the plant-mediated transport through its tissues. In addition, as a result of the land use history, mixed soil material due to peat extraction and refilling can serve as an explanation. With regards to the long time span passed since rewetting, we note that the initial increase in CH4 emissions due to rewetting as described in the literature is not inevitably limited to a short-term period.

  6. Competition and trade in Australian gas markets

    International Nuclear Information System (INIS)

    Holmes, Leanne; Mander, Sally

    1993-01-01

    Although Australia has large gas reserves, the bulk of reserves (about 80 per cent) are located on the North West Shelf, off Western Australia. On the other had, the major demand centres are located in the south east of the country. The relative scarcity of proven gas reserves close to major markets has meant that governments in the state and territories with reserves have a strong vested interest in the future use of the gas. Equally, governments in states and territories that do not have gas reserves are interested in securing future supplies. The scope for increasing competition and trade in Australian gas markets depends on a number of features of the industry. These include: the characteristics of the resource, the structure of supply including the presence of natural monopolies, the nature and extent of upstream or downstream integration of firms and the presence of long term contracts - the characteristics of gas demand, and the regulatory and policy framework. The main purpose in this article is to review the economic factors driving natural gas markets in Australia, highlighting the factors influencing competition and trade. Against this background, some options for reform are also examined. 30 refs., 6 figs

  7. 32 CFR 635.4 - Administration of expelled or barred persons file.

    Science.gov (United States)

    2010-07-01

    ... expulsion action is predicated on information contained in military police investigative records, the bar or expulsion document will reference the appropriate military police record or MPR. When a MPR results in the... into COPS, in the Military Police Reporting System module, under Barrings. ...

  8. Deteksi Kebocoran Gas LPG Menggunakan Detektor Arduino dengan Algoritma Fuzzy Logic Mandani

    Directory of Open Access Journals (Sweden)

    Lukman Hakim

    2017-10-01

    Full Text Available Bencana kebakaran yang diakibatkan oleh kebocoran gas LPG (Liquid  Petroleum   Gas mengalami kenaikan setiap tahun dari tahun 2011 sampai 2015 diantaranya 17% diakibatkan oleh kebocoran gas. Penggunaan detektor kebocoran gas LPG menggunakan arduino yang dilengkapi sensor gas dan suhu memberikan kemudahan untuk deteksi secara awal terjadinya kebocoran dan kebakaran. Perancangan detektor kebocoran gas LPG menggunakan algoritma fuzzy logic mandani, dilengkapi dengan informasi melalui Short Message Service (SMS dan Buzzer. Detektor kebocoran gas LPG dapat melakukan indikasi terjadinya bocor pada konsentrasi gas rata-rata 456 ppm dari 10 pengujian dan indikasi api merah 23,30 dapat mengenal terjadinya kebakaran, detektor mengirimkan SMS kepada pemilik rumah dan pemadam kebakaran.

  9. Canadian natural gas and climate change

    International Nuclear Information System (INIS)

    2002-03-01

    The Canadian Gas Association (CGA) has expressed concerns regarding how the goal to reduce greenhouse gas emissions can be met. It also has concerns regarding the possible economic impacts of required measures to reduce emissions to 6 per cent below 1990 levels. The CGA argued that since the initial negotiations of the Kyoto Protocol, Canada's greenhouse gas emissions have increased significantly, meaning that if the agreement were to come into force, Canada would have to reduce emissions by about 29 per cent below the currently-projected 2008-2012 level. The report states that 28 per cent of Canada's energy needs are met by natural gas. Excluding energy use in transportation, natural gas contributes more than 40 per cent to Canada's energy portfolio. More than half of Canadian households rely on pipeline services and distribution companies to deliver natural gas for household use. The manufacturing sector relies on natural gas for more than half of its energy needs. Natural gas is a major energy source for the iron/steel, petroleum refining and chemical manufacturing industries. Natural gas is a cleaner-burning fuel than coal or crude oil, and its use results in fewer environmental impacts than other fossil fuels. Vehicles powered by natural gas produce 20 - 30 per cent less carbon dioxide emissions than vehicles powered by gasoline. Pipelines are also a more efficient way of transporting and distributing natural gas than marine transport, railways or trucks. The CGA recommends that policy development should emphasize the environmental benefits of natural gas and recognize its role as a bridge fuel to a cleaner energy-based economy. It also recommends that policies should be developed to encourage the use of natural gas in electricity generation to lower greenhouse gases and air pollutants such as oxides of nitrogen that cause smog

  10. Aerodynamic findings and Voice Handicap Index in Parkinson's disease.

    Science.gov (United States)

    Motta, Sergio; Cesari, Ugo; Paternoster, Mariano; Motta, Giovanni; Orefice, Giuseppe

    2018-04-23

    To verify possible relations between vocal disability and aerodynamic measures in selected Parkinson's disease (PD) patients with low/moderate-grade dysphonia. Fifteen idiopathic dysphonic PD male patients were examined and compared with 15 euphonic subjects. Testing included the following measures: Voice Handicap Index (VHI), maximum phonation time (MPT), mean estimated subglottal pressure (MESGP), mean sound pressure level (MSPL), mean phonatory power (MPP), mean phonatory efficiency (MPE) and mean phonatory resistance (MPR). Statistical analysis showed: a significant reduction in MPR and MSPL in PD subjects compared to the healthy ones; a significant positive correlation between VHI score and MSPL, MPR, MPP, MESGP and a significant negative correlation between VHI and MTP within PD subjects. Test for multiple linear regression showed a significant correlation between VHI score, MPT, MPR and MSPL. A relationship between VHI and aerodynamic measures was shown in the present study. Compensatory mechanisms may aggravate vocal disability in PD subjects.

  11. Magma reservoirs and neutral buoyancy zones on Venus - Implications for the formation and evolution of volcanic landforms

    Science.gov (United States)

    Head, James W.; Wilson, Lionel

    1992-01-01

    The production of magma reservoirs and neutral buoyancy zones (NBZs) on Venus and the implications of their development for the formation and evolution of volcanic landforms are examined. The high atmospheric pressure on Venus reduces volatile exsolution and generally serves to inhibit the formation of NBZs and shallow magma reservoirs. For a range of common terrestrial magma-volatile contents, magma ascending and erupting near or below mean planetary radius (MPR) should not stall at shallow magma reservoirs; such eruptions are characterized by relatively high total volumes and effusion rates. For the same range of volatile contents at 2 km above MPR, about half of the cases result in the direct ascent of magma to the surface and half in the production of neutral buoyancy zones. NBZs and shallow magma reservoirs begin to appear as gas content increases and are nominally shallower on Venus than on earth. For a fixed volatile content, NBZs become deeper with increasing elevation: over the range of elevations treated in this study (-1 km to +4.4 km) depths differ by a factor of 2-4. Factors that may account for the low height of volcanoes on Venus are discussed.

  12. Micro turbines on gas

    International Nuclear Information System (INIS)

    Kotevski, Darko

    2003-01-01

    Microturbines are small gas turbine engines that drive a generator with sizes ranging from 30-350 kW. Although similar in function to bigger gas turbines, their simple radial flow turbine and high-speed generator offer better performance, greater reliability, longer service intervals, reduced maintenance lower emission and lower noise. Microturbines can generate power continuously and very economically to reduce electricity costs or they can be operated selectively for peak shaving. These benefits are further enhanced by the economics of using the microturbine's waste heat for hot water needs or other heating applications. That is why on-site microturbine power is widely used for independent production of electricity and heat in industrial and commercial facilities, hotels, hospitals, office buildings, residential buildings etc. (Original)

  13. Opening of the French gas market

    International Nuclear Information System (INIS)

    Syrota, J.

    2002-01-01

    A report on the opening of the French gas market has been established, on the request of both the French minister of economy, finances and industry and the state secretary of industry, as expressed in their respective letters addressed to the president of the commission of electric power regulation (CRE). This report follows the step report on the opening of the French gas market published on January 15, 2002. It presents a status of the French gas market since August 2000, date of the enforcement of the European Union directive 98/30/CE, and expresses some recommendations about the main questions that should fall into the field of the future gas regulation. This report was elaborated before the project of law relative to the energy markets and published on October 24, 2002. These recommendations will have to be adapted to the dispositions of the law. This article presents some excerpts of the synthesis report. (J.S.)

  14. Program for aerodynamic performance tests of helium gas compressor model of the gas turbine high temperature reactor (GTHTR300)

    International Nuclear Information System (INIS)

    Takada, Shoji; Takizuka, Takakazu; Kunimoto, Kazuhiko; Yan, Xing; Itaka, Hidehiko; Mori, Eiji

    2003-01-01

    Research and development program for helium gas compressor aerodynamics was planned for the power conversion system of the Gas Turbine High Temperature Reactor (GTHTR300). The axial compressor with polytropic efficiency of 90% and surge margin more than 30% was designed with 3-dimensional aerodynamic design. Performance and surge margin of the helium gas compressor tends to be lower due to the higher boss ratio which makes the tip clearance wide relative to the blade height, as well as due to a larger number of stages. The compressor was designed on the basis of methods and data for the aerodynamic design of industrial open-cycle gas-turbine. To validate the design of the helium gas compressor of the GTHTR300, aerodynamic performance tests were planned, and a 1/3-scale, 4-stage compressor model was designed. In the tests, the performance data of the helium gas compressor model will be acquired by using helium gas as a working fluid. The maximum design pressure at the model inlet is 0.88 MPa, which allows the Reynolds number to be sufficiently high. The present study is entrusted from the Ministry of Education, Culture, Sports, Science and Technology of Japan. (author)

  15. 75 FR 28602 - Corning Natural Gas Corporation; Notice of Compliance Filing

    Science.gov (United States)

    2010-05-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-30-003] Corning Natural Gas Corporation; Notice of Compliance Filing May 17, 2010. Take notice that on May 10, 2010, Corning Natural Gas Corporation, (Corning) filed a corrected rate sheet to replace the rate sheet filed with its...

  16. Low Temperature Particle Filtration of Wood Gas with Low Tar Content

    DEFF Research Database (Denmark)

    Hindsgaul, Claus; Henriksen, Ulrik Birk; Bentzen, Jens Dall

    2002-01-01

    Baghouse filters and cartridge filters were tested online with wood gas from a two stage down draft gasifier. The gas contained soot and very low levels (10-30 mg/Nm³) of tar. Particle collection efficiencies were above 95%. Continuous operation with cheap self cleaning baghouse filters were test...

  17. 30 CFR 256.80 - Leases of other minerals.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Leases of other minerals. 256.80 Section 256.80 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF SULPHUR OR OIL AND GAS IN THE OUTER CONTINENTAL SHELF Section 6 Leases § 256.80 Leases of other minerals. The...

  18. 30 CFR 250.1626 - Tubing and wellhead equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Tubing and wellhead equipment. 250.1626 Section... GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Sulphur Operations § 250.1626 Tubing and wellhead equipment. (a) No tubing string shall be placed into service or continue to be used unless such...

  19. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  20. Investigation on the conditions mitigating membrane fouling caused by TiO{sub 2} deposition in a membrane photocatalytic reactor (MPR) used for dye wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Damodar, Rahul-Ashok [Department of Bioenvironmental Engineering and R and D Center for Membrane Technology, Chung Yuan Christian University, Chung li 320, Taiwan, ROC (China); You, Sheng-Jie, E-mail: sjyou@cycu.edu.tw [Department of Bioenvironmental Engineering and R and D Center for Membrane Technology, Chung Yuan Christian University, Chung li 320, Taiwan, ROC (China); Chiou, Guan-Wei [Department of Civil Engineering, Chung Yuan Christian University, Chung li 320, Taiwan, ROC (China)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer The charge differences between particle and membrane accelerate the intensity of fouling and binding of TiO{sub 2} particles. Black-Right-Pointing-Pointer Severe fouling at pH 5 and low fouling at pH {>=} 7 at all flux conditions. Black-Right-Pointing-Pointer The presence of a very thin TiO{sub 2} cake layer can alter the hydrophilicity of the membrane surface. Black-Right-Pointing-Pointer The resistance offered by dense TiO{sub 2} cake layer could dominate the hydrophilic effect of TiO{sub 2} particles. - Abstract: In this study, the effects of MPR's operating conditions such as permeate flux, solution pH, and membrane hydrophobicity on separation characteristics and membrane fouling caused by TiO{sub 2} deposition were investigated. The extent of fouling was measured in terms of TMP and tank turbidity variation. The results showed that, at mildly acidic conditions (pH {approx} 5), the turbidity within the tank decreased and the extent of turbidity drop increased with increasing flux for all the membranes. On the other hand, at pH {>=} 7, the turbidity remained constant at all flux and for all membranes tested. The fouling variation at different pH was closely linked with the surface charge (zeta potential) and hydrophilicity of both membrane and particles. It was observed that the charge differences between the particles and membranes accelerate the intensity of fouling and binding of TiO{sub 2} particles on the membrane surface under different pH conditions. The presence of a very thin layer of TiO{sub 2} can alter the hydrophilicity of the membranes and can slightly decrease the TMP (filtration resistance) of the fouled membranes. Besides, the resistance offered by the dense TiO{sub 2} cake layer would dominate this hydrophilic effect of TiO{sub 2} particles, and it may not alter the filtration resistance of the fouled membranes.

  1. Microbial electrolysis contribution to anaerobic digestion of waste activated sludge, leading to accelerated methane production

    DEFF Research Database (Denmark)

    Liu, Wenzong; Cai, Weiwei; Guo, Zechong

    2016-01-01

    Methane production rate (MPR) in waste activated sludge (WAS) digestion processes is typically limitedby the initial steps of complex organic matter degradation, leading to a limited MPR due to sludgefermentation speed of solid particles. In this study, a novel microbial electrolysis AD reactor (ME...

  2. Modification of the motor control system of secondary cooling pumps of the multipurpose reactor - GA Siwabessy (RSG-GAS) to overcome the electrical flicking

    International Nuclear Information System (INIS)

    Yayan Andriyanto; Tufiq, M.; Adin Sudirman; Koes Indrakoesoema

    2012-01-01

    Modification of the motor control system of secondary cooling pumps that have been carried out to overcome the electrical flicking. Consequences of unanticipated flicking is the cooling pumps will shut down. Modification is done by replacing the control system PLN to Uninterruptible Power Supply (UPS), plus a component of Miniature Circuit Breaker (MCB) 220 Volt 2 Amp 2 Pole, 2 Auxiliary Contactor-type 3RH1131-1APOO with 1 NO auxiliary contact (normally Open) and two time-1BP30-3RP1505 type relay (off delay). Delay time to overcome the electrical flicking is set to 1 seconds and 2 seconds, taking into calculate the electrical flicking that occurred while in the setting of time limits, the predicted secondary cooling water pressure inside the pipeline is still eligible and the motor cooling system operation can still continue to operate. In the flicking of an electrical incident on 13 April 2010 at 0:45 Pm showed that the modifications of the secondary coolant pump motors operation when the reactor operates with a power of 15 MW. (author)

  3. Danish greenhouse gas reduction scenarios for 2020 and 2050

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, K; Joergensen, Kaj [Risoe DTU, Roskilde (DK); Werling, J; OErsted Pedersen, H; Kofoed-Wiuff, A [Ea energy Analysis, Copenhagen (DK)

    2008-02-15

    The aim of the project presented in this report was to develop scenarios for reducing Danish greenhouse gas emissions in 2020 and 2050. The scenarius provide a basis for estimating which technologies should be combined in order to obtain future reductions in greenhouse gas emissions in a cost-effective way. The scenarios include all emissions of greenhouse gases from agriculture, industry and oil extraction activities in the North Sea as well as the transport and energy sectors. Foreign air and sea carriage is not included because emissions related to such activities are not yet subject to international climate change agreements. The scenarios focus particularly on the technological possibilities and the necessary system changes in the Danish energy system and transport sector. Parallel to this, COWI has carried out analyses for the Danish Environmental Protection Agency focussing primarily on the reduction potentials in the transport sector and other emissions. COWI's results regarding agriculture and other emissions have been included in this analysis. Two timeframes are applied in the scenarios: the medium term, 2020, and the long term, 2050. For each timeframe, we have set up indicative targets that the scenarios must reach: 1) 2020: 30 and 40 % reduction in greenhouse gas emissions compared to 1990 2) 2050: 60 and 80 % reduction in greenhouse gas emissions compared to 1990. The scenarios for 2020 focus primarily on technologies that are already commercially available, whereas the scenarios for 2050 also examine technological options at the experimental or developmental stage. This includes hydrogen technologies and fuel cells as well as CO{sub 2} capture and sequestration (CCS) technologies. The scenarios should be seen in connection with the EU objectives of a 20-30 % reduction in greenhouse gas emissions in 2020 and 60-80 % in 2050 compared to 1990. The EU's 30 % objective is contingent upon global efforts to reduce the world's greenhouse gas emissions

  4. Evaluation of an active humidification system for inspired gas.

    Science.gov (United States)

    Roux, Nicolás G; Plotnikow, Gustavo A; Villalba, Darío S; Gogniat, Emiliano; Feld, Vivivana; Ribero Vairo, Noelia; Sartore, Marisa; Bosso, Mauro; Scapellato, José L; Intile, Dante; Planells, Fernando; Noval, Diego; Buñirigo, Pablo; Jofré, Ricardo; Díaz Nielsen, Ernesto

    2015-03-01

    The effectiveness of the active humidification systems (AHS) in patients already weaned from mechanical ventilation and with an artificial airway has not been very well described. The objective of this study was to evaluate the performance of an AHS in chronically tracheostomized and spontaneously breathing patients. Measurements were quantified at three levels of temperature (T°) of the AHS: level I, low; level II, middle; and level III, high and at different flow levels (20 to 60 L/minute). Statistical analysis of repeated measurements was performed using analysis of variance and significance was set at a P<0.05. While the lowest temperature setting (level I) did not condition gas to the minimum recommended values for any of the flows that were used, the medium temperature setting (level II) only conditioned gas with flows of 20 and 30 L/minute. Finally, at the highest temperature setting (level III), every flow reached the minimum absolute humidity (AH) recommended of 30 mg/L. According to our results, to obtain appropiate relative humidity, AH and T° of gas one should have a device that maintains water T° at least at 53℃ for flows between 20 and 30 L/m, or at T° of 61℃ at any flow rate.

  5. Characterization and role of a metalloprotease induced by chitin in Serratia sp. KCK.

    Science.gov (United States)

    Kim, Hyun-Soo; Golyshin, Peter N; Timmis, Kenneth N

    2007-11-01

    A metalloprotease induced by chitin in a new chitinolytic bacterium Serratia sp. Strain KCK was purified and characterized. Compared with other Serratia enzymes, it exhibited a rather broad pH activity range (pH 5.0-8.0), and thermostability. The cognate ORF, mpr, was cloned and expressed. Its deduced amino acid sequence showed high similarity to those of bacterial zinc-binding metalloproteases and a well-conserved serralysin family motif. Pretreatment of chitin with the Mpr protein promoted chitin degradation by chitinase A, which suggests that Mpr participates in, and facilitates, chitin degradation by this microorganism.

  6. Application of Fiscal Incentives for Development of East Natuna Gas Field for Long-Term National Natural Gas Demand

    Directory of Open Access Journals (Sweden)

    Marwan Batubara

    2015-08-01

    Full Text Available East Natuna gas field, which has proven reserves of 46 trillion cubic feet, is projected to meet long-term natural gas needs. However, CO2-content of the gas reserves reaches 71%, leading to expensive development costs. This research investigates the feasibility of the field based on several fiscal incentives. Firstly, gas supply-demand until year 2040 was analyzed. Then, based on the analysis, the field was developed using high CO2 gas separation technology to produce gas of 1300 MMSCFD in 2023, 2600 MMSCFD in 2031, and 3900 MMSCFD in 2039. Finally, the economic feasibility was assessed using cash flow analysis in accordance with Indonesia’s production sharing contract scheme. The results show that the supply-demand gap continues to increase and thus the development is urgently needed. The development cost is estimated around US$ 27.59 billion. The gas selling prices are assumed at US$ 8/MMBTU for wellhead, US$ 11/MMBTU for pipelines, and US$ 11/MMBTU for LNG. To achieve minimum IRR value of 12%, the government needs to offer incentives of 30-year contract period, profit sharing of 55%: 45%, first tranche petroleum to 10%, and tax holiday of 10 years. Toll fee for Natuna-Cirebon pipeline is US$ 2.3/MMBTU at IRR of 12.6%.

  7. Building the NGV [natural gas vehicle] industry into the 21st century

    International Nuclear Information System (INIS)

    Eaves, M.

    1992-01-01

    The status and potential of the natural gas vehicle (NGV) industry is reviewed. The current status of NGV technology is discussed, and a perspective on the business potential of NGV is offered. The cost of compressed natural gas is compared with the cost of conventional fuel options. At present there is a ca 92-97 cent/gallon differential between natural gas and gasoline, however it is not clear that this is sufficient to provide an incentive for purchasing a compressor. The economics of running a Sierra pickup truck are calculated, and it is proposed that a fuel cost differential in the order of 30 cents may be enough to entice consumers to purchase NGV. The gas industry is expected to finance the fuelling infrastructure for NGVs for the reasonable future. The investment must be made using a 25-40 cent per therm differential (or 30-50 cent/gallon equivalent) to finance compressor facilities. Extensive tables and graphs are presented that show the dependence of number of vehicles (and gas sales) on simple payback periods for compressor facilities. 4 figs., 19 tabs

  8. Adherence to anti-estrogen therapy in seniors with breast cancer: how well are we doing?

    Science.gov (United States)

    Trabulsi, Nora; Riedel, Kristen; Winslade, Nancy; Gregoire, Jean-Pierre; Meterissian, Sarkis; Abrahamovicz, Michal; Tamblyn, Robyn; Mayo, Nancy; Meguerditchian, Ari

    2014-01-01

    A third of breast cancers (BC) occur in women ≥65 years (seniors). Anti-estrogen therapy (AET) significantly reduces BC recurrence and death. This study characterizes determinants of adherence to AET in seniors with BC. Provincial cancer registry and administrative claims data were accessed for all non-metastatic BC diagnosed in Quebec (1998-2005) to identify seniors treated for 5 years with AET. Multivariate linear regression was used to assess the association with patient, disease, and physician characteristics and the 5-year medication possession ratio (MPR) for each patient. 4,715 women were included (mean age: 72.9). Mean MPR was 83.5%, 79% of patients reached a 5-year MPR of ≥80%, and 34% discontinued AET at some point during treatment. The cumulative probability of discontinuation was 33.8% (mean time to discontinuation 2.3 years). The MPR decreased with increasing age and non-BC related hospitalizations, p seniors with BC remained a challenge and medication discontinuation rates were high. Advanced age, increasing number of hospitalizations, in situ disease, baseline use of antidepressants, Tamoxifen (versus aromatase inhibitors), early switches of AET type, and newly added medications significantly reduced the MPR. © 2014 Wiley Periodicals, Inc.

  9. Journal of EEA, Vol. 30, 2013 SIEVE TRAY EFFICIENCY USING ...

    African Journals Online (AJOL)

    dell

    Journal of EEA, Vol. 30, 2013. SIEVE TRAY EFFICIENCY USING CFD MODELING AND SIMULATION ... ABSTRACT. In this work, computational fluid dynamics (CFD) .... per unit volume, MG is the molecular weight of the gas/vapor, kL and kG ...

  10. Precise half-life measurement of the superallowed emitter 30S

    Science.gov (United States)

    Iacob, V. E.; Hardy, J. C.; Chen, L.; Horvat, V.; Bencomo, M.; Nica, N.; Park, H. I.; Roeder, B. T.; Saastamoinen, A.

    2018-03-01

    We have measured the half-life of 30S, the parent of a superallowed 0+→0+β transition, to a high precision using very pure sources and a 4 π proportional gas counter to detect the decay positrons. Our result for the half-life is 1.179 92(34) s. As a by-product of this measurement, we determine the half-life of its daughter, 30P, to be 2.501(2) min.

  11. The perspectives of the natural gas in Mexico; Las perspecivas del gas natural en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez S, Luis [DIAVAZ S.A de C.V, Mexico, D.F. (Mexico)

    2001-07-01

    As never before in the last year we have suffered the increases in the cost of the natural gas. For those who are not aware, the prices have gone from 2.48 dollars per million BTU a year ago to 9.57 last month. The truth is that we are facing a true world-wide energy crisis. From one year to date the prices of all the energy sources have increased an average superior to 30%, including increases in Diesel oil, LP Gas, Natural Gas, Turbine fuel. The causes are many and very varied, from efficiency decisions, as in the case of the electrical Generation that has chosen to incline definitively to the natural gas, confusing de-regulations as in the case of California, increases of demand beyond the anticipated by economic activity, changes of consumption pattern, etc.. This demonstrates the well focussed and the opportunity of this Seminar, since there is no doubt that it has become imperative a single and efficient criterium on this so limited resource. In Mexico, the situation is very similar. Recently a measurement has been implemented that tries to palliate the conjunctural effects of this crisis and PEMEX has put to the disposition of the users a contract at fixed price, for three years and by a specific amount. [Spanish] Como nunca antes en el ultimo ano hemos resentido los incrementos en el gasto del gas natural. Para quien no este al tanto los precios han pasado de 2.48 dolares por millon de BTU hace un ano a 9.57 el mes pasado. La verdad es que os estamos enfrentando a una verdadera crisis energetica mundial. De un ano para aca todos los energeticos han aumentado un promedio superior al 30%, incluyendo aumentos en Diesel, Gas LP, Gas Natural, Turbosina. Las causas son muchas y muy variadas, desde decisiones de eficiencia, como en el caso de la Generacion electrica que ha optado por inclinarse definitivamente por el gas natural, desregulaciones confusas como en el caso de California, incrementos de demanda mas alla de lo previsto por actividad economica, cambios

  12. The Component And System Reliability Analysis Of Multipurpose Reactor G.A. Subway's Based On The Failure Rate Curve

    International Nuclear Information System (INIS)

    Sriyono; Ismu Wahyono, Puradwi; Mulyanto, Dwijo; Kusmono, Siamet

    2001-01-01

    The main component of Multipurpose G.A.Siwabessy had been analyzed by its failure rate curve. The main component ha'..e been analyzed namely, the pump of ''Fuel Storage Pool Purification System'' (AK-AP), ''Primary Cooling System'' (JE01-AP), ''Primary Pool Purification System'' (KBE01-AP), ''Warm Layer System'' (KBE02-AP), ''Cooling Tower'' (PA/D-AH), ''Secondary Cooling System'', and Diesel (BRV). The Failure Rate Curve is made by component database that was taken from 'log book' operation of RSG GAS. The total operation of that curve is 2500 hours. From that curve it concluded that the failure rate of components form of bathtub curve. The maintenance processing causes the curve anomaly

  13. Natural gas pipeline technology overview.

    Energy Technology Data Exchange (ETDEWEB)

    Folga, S. M.; Decision and Information Sciences

    2007-11-01

    The United States relies on natural gas for one-quarter of its energy needs. In 2001 alone, the nation consumed 21.5 trillion cubic feet of natural gas. A large portion of natural gas pipeline capacity within the United States is directed from major production areas in Texas and Louisiana, Wyoming, and other states to markets in the western, eastern, and midwestern regions of the country. In the past 10 years, increasing levels of gas from Canada have also been brought into these markets (EIA 2007). The United States has several major natural gas production basins and an extensive natural gas pipeline network, with almost 95% of U.S. natural gas imports coming from Canada. At present, the gas pipeline infrastructure is more developed between Canada and the United States than between Mexico and the United States. Gas flows from Canada to the United States through several major pipelines feeding U.S. markets in the Midwest, Northeast, Pacific Northwest, and California. Some key examples are the Alliance Pipeline, the Northern Border Pipeline, the Maritimes & Northeast Pipeline, the TransCanada Pipeline System, and Westcoast Energy pipelines. Major connections join Texas and northeastern Mexico, with additional connections to Arizona and between California and Baja California, Mexico (INGAA 2007). Of the natural gas consumed in the United States, 85% is produced domestically. Figure 1.1-1 shows the complex North American natural gas network. The pipeline transmission system--the 'interstate highway' for natural gas--consists of 180,000 miles of high-strength steel pipe varying in diameter, normally between 30 and 36 inches in diameter. The primary function of the transmission pipeline company is to move huge amounts of natural gas thousands of miles from producing regions to local natural gas utility delivery points. These delivery points, called 'city gate stations', are usually owned by distribution companies, although some are owned by

  14. Direct analysis of ultra-trace semiconductor gas by inductively coupled plasma mass spectrometry coupled with gas to particle conversion-gas exchange technique.

    Science.gov (United States)

    Ohata, Masaki; Sakurai, Hiromu; Nishiguchi, Kohei; Utani, Keisuke; Günther, Detlef

    2015-09-03

    An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L(-1) and 2.4 nL L(-1) for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L(-1) and 30 nL L(-1) for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. 30 CFR 256.25 - Areas near coastal States.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Areas near coastal States. 256.25 Section 256... SULPHUR OR OIL AND GAS IN THE OUTER CONTINENTAL SHELF Call for Information and Nominations § 256.25 Areas near coastal States. (a) At the time information is solicited for leasing of areas within 3...

  16. Effects of microclimatic variables on the symptoms and signs onset of Moniliophthora roreri, causal agent of Moniliophthora pod rot in cacao.

    Directory of Open Access Journals (Sweden)

    Mariela E Leandro-Muñoz

    Full Text Available Moniliophthora Pod Rot (MPR caused by the fungus Moniliophthora roreri (Cif. Evans et al., is one of the main limiting factors of cocoa production in Latin America. Currently insufficient information on the biology and epidemiology of the pathogen limits the development of efficient management options to control MPR. This research aims to elucidate MPR development through the following daily microclimatic variables: minimum and maximum temperatures, wetness frequency, average temperature and relative humidity in the highly susceptible cacao clone Pound-7 (incidence = 86% 2008-2013 average. A total of 55 cohorts totaling 2,268 pods of 3-10 cm length, one to two months of age, were tagged weekly. Pods were assessed throughout their lifetime, every one or two weeks, and classified in 3 different categories: healthy, diseased with no sporulation, diseased with sporulating lesions. As a first step, we used Generalized Linear Mixed Models (GLMM to determine with no a priori the period (when and for how long each climatic variable was better related with the appearance of symptoms and sporulation. Then the significance of the candidate variables was tested in a complete GLMM. Daily average wetness frequency from day 14 to day 1, before tagging, and daily average maximum temperature from day 4 to day 21, after tagging, were the most explanatory variables of the symptoms appearance. The former was positively linked with the symptoms appearance when the latter exhibited a maximum at 30°C. The most important variables influencing sporulation were daily average minimum temperature from day 35 to day 58 and daily average maximum temperature from day 37 to day 48, both after tagging. Minimum temperature was negatively linked with the sporulation while maximum temperature was positively linked. Results indicated that the fungal microclimatic requirements vary from the early to the late cycle stages, possibly due to the pathogen's long latent period. This

  17. Effects of microclimatic variables on the symptoms and signs onset of Moniliophthora roreri, causal agent of Moniliophthora pod rot in cacao.

    Science.gov (United States)

    Leandro-Muñoz, Mariela E; Tixier, Philippe; Germon, Amandine; Rakotobe, Veromanitra; Phillips-Mora, Wilbert; Maximova, Siela; Avelino, Jacques

    2017-01-01

    Moniliophthora Pod Rot (MPR) caused by the fungus Moniliophthora roreri (Cif.) Evans et al., is one of the main limiting factors of cocoa production in Latin America. Currently insufficient information on the biology and epidemiology of the pathogen limits the development of efficient management options to control MPR. This research aims to elucidate MPR development through the following daily microclimatic variables: minimum and maximum temperatures, wetness frequency, average temperature and relative humidity in the highly susceptible cacao clone Pound-7 (incidence = 86% 2008-2013 average). A total of 55 cohorts totaling 2,268 pods of 3-10 cm length, one to two months of age, were tagged weekly. Pods were assessed throughout their lifetime, every one or two weeks, and classified in 3 different categories: healthy, diseased with no sporulation, diseased with sporulating lesions. As a first step, we used Generalized Linear Mixed Models (GLMM) to determine with no a priori the period (when and for how long) each climatic variable was better related with the appearance of symptoms and sporulation. Then the significance of the candidate variables was tested in a complete GLMM. Daily average wetness frequency from day 14 to day 1, before tagging, and daily average maximum temperature from day 4 to day 21, after tagging, were the most explanatory variables of the symptoms appearance. The former was positively linked with the symptoms appearance when the latter exhibited a maximum at 30°C. The most important variables influencing sporulation were daily average minimum temperature from day 35 to day 58 and daily average maximum temperature from day 37 to day 48, both after tagging. Minimum temperature was negatively linked with the sporulation while maximum temperature was positively linked. Results indicated that the fungal microclimatic requirements vary from the early to the late cycle stages, possibly due to the pathogen's long latent period. This information is

  18. Competition in trade with natural gas

    International Nuclear Information System (INIS)

    1999-01-01

    On 22 June 1998, the European Parliament and the Council of Europe adopted Directive 98/30/EC on common rules for the internal market for natural gas. The Natural Gas Market Directive is aimed at increasing the competition on the gas market and creating an internal market for natural gas. To achieve this, the Directive includes provisions for ensuring that owners of transmission and distribution networks will allow other players access to these networks. The Directive is much more far-reaching and comprehensive than the present Swedish legislation in the field of natural gas. The main task of the committee is to submit a proposal for natural gas legislation that will meet the requirements of the new Directive. According to the committee directives, the work on the new legislation should aim at the regulations serving as a basis for a socio economically efficient market. However, it should also be borne in mind that the Swedish natural gas market is less developed than the markets in most other European countries, and that a lack of equilibrium in the opening of the gas markets should be avoided. Current international deliberations concerning the natural gas network in the Nordic countries and the Baltic Sea region should also be taken into account. Chapter 1 gives more detailed particulars of the points of departure for the work of the committee and the implementation of the work. The report is arranged in the form three main parts, i.e. a background part, a part describing the points of departure, and a proposals part

  19. Natural gas development in the Russian Far East

    International Nuclear Information System (INIS)

    Khartukov, E.M.

    1994-01-01

    The poorly explored and mostly underdeveloped gas resources of the Russian Far East (RFE) are large enough to support several large-scale projects, with an aggregate exportable surplus of up to 30 bcm of natural gas a year. However, owing to the uncertainties of the regional and national investment climate, new development projects, which heavily rely upon invited foreign participation, are likely to be delayed and will hardly yield, by the year 2000, more than 10 bcm of Russian gas for export. Nevertheless, in the forecastable future the region will emerge as an important player in the Asia-Pacific energy market and, consequently, in this area's geopolitical arena as well. (author)

  20. Basic study for Joint Implementation Pipeline System Optimization Project including rehabilitation of gas pipeline in Ukraine for greenhouse gas reduction

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of reducing greenhouse effect gas emissions, a study was conducted of a project for repair/optimization of the Shebelinka, Dikanka-Kyiv, gas pipeline system in the Republic of Ukraine. As a result of the study, the following plans were proposed. The gas turbine compressor now in use has been used more than 30 years, and is needed to be changed due to the superannuation. Changes are needed of the equipment used for pipeline inspection, corrosion prevention equipment, damaged data collecting equipment, pressure detection automatic drive valve, etc. Further needed are a portable compressor by which repair work can be done without gas release into the atmospheric air. The investment required for repair/installation of these equipment totaled approximately 216 million dollars. This brings the reduction in greenhouse effect gas emissions of 512,000 tons/year, and the energy conservation of 103,000 tons/year of crude oil or its equivalent. These are estimated at about 10 million dollars in greenhouse effect gas reduction and at 15 million dollars in energy conservation. (NEDO)

  1. Gas cluster ion beam equipments for industrial applications

    International Nuclear Information System (INIS)

    Matsuo, J.; Takaoka, G.H.; Yamada, I.

    1995-01-01

    30 keV and 200 keV gas cluster ion beam equipments have been developed for industrial applications. A gas cluster source with a non-cooled nozzle was used for both the equipments. Sufficient monomer ion suppression was achieved by using an ExB filter and chromatic lenses mass filter with low extraction voltage. These equipments are suitable to be used for low-damage surface treatment of metals, insulators and semiconductors without heavy metal contamination. (orig.)

  2. The Reforming States Group and the Promotion of Federalism

    Science.gov (United States)

    Andersen, Kathleen S.

    1998-01-01

    Since 1991, leaders in health policy from the legislative and executive branches of state government have come together, with financial support and staff collaboration from the Milbank Memorial Fund, to share their experiences and to work on practical solutions to pressing health care problems. What began with a handful of states at the forefront of health reform is now the Reforming States Group (RSG), a bipartisan, voluntary association that includes leaders from over 40 states. This article describes the origins, history, and future prospects of the RSG. PMID:9510901

  3. Metallurgical analysis of high pressure gas pipelines rupture

    International Nuclear Information System (INIS)

    Hasan, F.; Ahmed, F.

    2007-01-01

    On 6 July 2004, two parallel-running gas pipelines (18-inch and 24-inch diameters), in the main transmission network of SNGPL (a gas company in Pakistan) were ruptured. The ruptures occurred in the early hours of the morning about 8 miles downstream of the compressor station AC-4. The ruptures were indicated by the increased gas flow at the outlet of AC-4 (1), first at about 0648 hours and then again about 20 minutes later. The gas escaping from the ruptured lines had caught fire, and the flames had also 'affected' a third parallel-running pipeline of 30-inch diameter, lying next to the 24-inch line. The metallurgical examination of the two ruptured lines showed that the 24-inch line was ruptured with the help of an explosive device that had been placed on the underside of the pipe. An examination of the 18-inch line showed that this pipe had failed as a result of the heating of the pipe-wall, presumably, by the flame emanating from the 24-inch line. These two observations clearly suggested that the 24-inch line was the first to rupture (by explosives), and the fire following this rupture had heated the 18-inch pipe to a temperature where its yield strength was unable to support the inside gas pressure. The 20 minutes time interval between the two ruptures was obviously the time taken by the 18 inch pipe to be heated upto the level where it started to yield. The 30-inch line lying next to the 24-inch line was affected to the extent that its coating had been burnt-off over a length of about 40-50 feet. However, the pipe did not exhibit any signs of deshaping or deformation what-so-ever. A replica metallographic examination indicated that the microstructure of the pipe was not measurably affected by the heat. It was thus decided not to replace the affected part of the 30-inch pipe, but only to re-coat this affected portion. (author)

  4. Transposition of the gas directive in French law

    International Nuclear Information System (INIS)

    Anon.

    2002-01-01

    On September 25, 2002, the French government adopted the project of law relative to the energy markets. This project of law takes up the essential part of the measures proposed by the directive no 98/30/CE of the European Union from June 22, 1998, about the 'common rules of the internal natural gas market'. This paper makes a brief comment of the version of this project adopted by the senate. It presents also the position of the French gas association (AFG) about this transposition, its action during the first phase of the parliamentary debate, and what will be AFG's role after the enforcement of this law. Finally, a testimony of the Swiss society of gas and waters industry (SSIGE) about the opening of the natural gas market is given in conclusion. (J.S.)

  5. Optimising Russian natural gas - reform and climate policy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-18

    The world's largest gas producer and exporter, Russia has an enormous energy saving potential. At least 30 billion cubic meters, a fifth of Russian exports to European OECD countries, could be saved every year by enhanced technology or energy efficiency. As the era of cheap gas in Russia comes to an end, this potential saving is increasingly important for Russians and importing countries. And, as domestic gas prices increase, efficiency investments will become increasingly economic - not to mention the incentive for Gazprom to enhance its efficiency against a backdrop of high European gas prices. The book analyzes and estimates the potential savings and the associated reductions in greenhouse gas emissions in the oil extraction (flaring), gas transmission, and distribution sectors. Achieving these savings will require linking long-standing energy efficiency goals with energy sector reforms, as well as climate policy objectives. The book also describes Russia's emerging climate policy and institutional framework, including work still ahead before the country is eligible for the Kyoto Protocol's flexibility mechanisms and can attract financing for greenhouse gas reductions. Stressed is the need for Russia to tap the full potential of energy savings and greenhouse gas emission reductions through a more competitive environment in the gas sector to attract timely investments.

  6. Use of micro gas chromatography in the fuel cycle of fusion reactors

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.; Kawamura, Y.

    2003-01-01

    Various analytical techniques exist to determine the compositions of gases handled in the fuel cycle of future fusion machines. Gas chromatography was found to be the most appropriate method. The main disadvantages of conventional gas chromatography were the long retention times for the heavy hydrogen species of >30 min. Recent progress in the development of micro-gas chromatography has reduced these retention times to ∼3 min. The usefulness of micro-gas chromatography for the analysis of hydrogen and impurity gas mixtures in the fuel cycle of future fusion machines is presented and the advantages and drawbacks are discussed

  7. Optimization of flow reserve measurement using SPECT technology to evaluate the determinants of coronary microvascular dysfunction in diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Cecilia [CNR Institute of Bioimages and Molecular Physiology, Milan, Section of Genoa (Italy); Bezante, GianPaolo; Modonesi, Elisa; Rollando, Daniela; Balbi, Manrico; Brunelli, Claudio [University of Genoa, Department of Internal Medicine, Cardiology, Genoa (Italy); Gandolfo, Patrizia; Morbelli, Silvia D.; Armonino, Riccardo [University of Genoa, Department of Internal Medicine, Nuclear Medicine, Genoa (Italy); DePascale, Angelo; Maggi, Davide; Albertelli, Manuela; Cordera, Renzo [University of Genoa, Department of Endocrinological Metabolic Sciences, Diabetology, Genoa (Italy); Sambuceti, Gianmario [University of Genoa, Department of Internal Medicine, Nuclear Medicine, Genoa (Italy); Advanced Biotechnology Center, Genoa (Italy)

    2010-02-15

    The aim of this study was to validate a new method to measure regional myocardial perfusion reserve (MPR) with technetium-labelled tracers in patients with type 2 diabetes mellitus (DM2). A total of 40 consecutive DM2 patients without history of coronary artery disease (CAD) and 7 control subjects were recruited. Dipyridamole myocardial blood flow index (MBF) was assessed by measuring first transit counts in the pulmonary artery and myocardial count rate from gated SPECT images using {sup 99m}Tc-labelled tracers. The corresponding MBF index was estimated 2 h later according to the same procedure. Regional myocardial perfusion reserve (MPR) was defined as the ratio between dipyridamole and baseline MBF using a 17-segment left ventricular (LV) model. Coronary flow reserve (CFR) was estimated by transthoracic contrast echo Doppler monitoring of flow velocity in the left anterior descending coronary artery (LAD) during the same session. Estimated MPR was higher in control subjects than in patients (3.36 {+-} 0.66 vs 1.91 {+-} 0.61, respectively, p < 0.01). In patients, LAD CFR and LAD MPR were 2.01 {+-} 0.78 vs 1.93 {+-} 0.63, respectively (p = ns). The agreement between the two techniques was documented by their close correlation (r = 0.92, p < 0.001) and confirmed by the Bland-Altman analysis. Reversible perfusion defects occurred in 13 patients (32%) who showed similar MPR values as the remaining 27 (2.10 {+-} 0.71 vs 1.83 {+-} 0.71, respectively, p = ns). Finally, MPR was closely correlated with age (r = -0.50, p < 0.01) and time elapsed from the diagnosis of DM2 (r = -0.51, p < 0.01). LV regional MPR can be accurately estimated with the broadly available single photon technology. Application of this method to DM2 patients documents the presence of a microvascular dysfunction homogeneously distributed throughout the LV walls and most frequently not associated with reversible perfusion defects. (orig.)

  8. The crude petroleum and natural gas industry : 1996

    International Nuclear Information System (INIS)

    1997-01-01

    Statistics regarding Canada's crude oil and natural gas industry for 1996 were presented. Data presentation was in tabular form, the topics being exploration and development, synthetic crude oil reserves, crude oil production and movements by source, natural gas production, drilling completions, net cash expenditures of the petroleum industry, and total sales of natural gas by province. Some of the noteworthy highlights for 1996 were: (1) 14,600 new wells were drilled, the highest number ever recorded, (2) capital investment was over $13 billion, (3) 148 companies were involved in mergers and acquisitions, (4) value of marketable production of oil, natural gas and natural gas by-products topped $30 billion, (5) Empress pipelines began operations of the first new major oil pipeline from Western Canada in 45 years, (6) the Hibernia offshore crude oil facility was completed, (7) Sable Island offshore energy projects applications were filed, and (8) the development of the Terra Nova, Whitehorse and Hebron fields was announced. 8 tabs

  9. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  10. 30 CFR 210.153 - What reports must I submit for Indian gas valuation purposes?

    Science.gov (United States)

    2010-07-01

    ...) Reporting address. You must submit completed Forms MMS-4410 and MMS-4411 by: (1) U.S. Postal Service regular... INTERIOR MINERALS REVENUE MANAGEMENT FORMS AND REPORTS Special-Purpose Forms and Reports-Oil, Gas, and... following forms: (1) Form MMS-4410, Accounting for Comparison (Dual Accounting), Part A or Part B; and/or (2...

  11. An evaluation of the regional cerebral blood flow (rCBF) measurement by xenon-enhanced dynamic CT with helical scanning technique and the functional imaging by multiplanar reconstruction (MPR). Fundamental study and clinical application

    International Nuclear Information System (INIS)

    Watanabe, Kenichi

    1997-01-01

    We evaluated the quantitative rCBF by xenon-enhanced dynamic CT with helical scanning technique on all brain regions, and also examined clinical usefulness of coronal and sagittal section images which are similar to SPECT images obtained by the functional multiplanar reconstitution (MPR) imaging of many successive flow maps. We used 14 clinical cases. The conventional xenon-enhanced CT was simple and ideal method to measure rCBF, however, it had disadvantages; it gives a few laminagraphical images or only the axial directional images, compared to SPECT or PET. There is a risk to overlook lesions out of the image or not to obtain the whole images of the lesion. Although the helical scanning technique has a methodological characteristics to use adjacent data for the image reconstitution, it is by no means inferior to the conventional method in the contrast resolution or the image resolution when the co-helical function and an appropriate reconstituted function were used. It has an advantage to scan all brain regions by only one cycle of scanning. Furthermore on making good use of the property that the helical scanning technique can give the successive data, we can observe rCBF by coronal and sagittal images when many flow maps were made up by reconstituted images of the narrow steps. This shows the clinical usefulness of this technique. One of the future problem to be solved is to decrease the exposure dose. (K.H.)

  12. The injection of ultrahigh rates of reducing gas into a modern blast furnace

    Energy Technology Data Exchange (ETDEWEB)

    Buergler, T.; Skoeld, B.E. [Voestalpine, Linz (Austria)

    2007-07-01

    The pilot plant for gas injection consists of a screw compressor unit to supply two blast furnaces with reduction gas. Almost all of the reducing gas will react in the raceway; only a small part will combust inside the tuyere. Comparing different injection systems in the case with two lances, the gas will react faster than for the one lance system where the gas is more trapped inside a beam. During the project the melting rate of the furnace was increased by more than 30 %. Injecting reducing gas compensates increased raceway adiabatic flame temperature, RAFT by higher oxygen enrichment rates. The operation results showed that a lower RAFT and low-quality raw material result in increased consumption of reducing agents. 1 kg coke oven gas, COG substitutes 0.81 kg oil and 1.03 kg coke. Sulfur input was reduced by 40 % in comparison with heavy fuel oil operation. The top-gas calorific value is increased up to 30 %. This reduces the consumption of natural gas used to control a constant calorific value in the gas network. A high hydrogen content up to 12 % is no problem for the gas consumers. Tests with simultaneous COG/BOF gas injection have shown that a decrease in the oil rate can be compensated. The replacement of a carbon-rich resultant such as coke and oil in the BF process with a carbon-lean resultant such as COG leads to an absolute reduction in the CO{sub 2} emissions of the BF process and the power plant of approximately 184.000 t/a for both BFs or 102 kg/tHM. 3 refs., 98 figs., 16 tabs., 1 annex.

  13. Validation of Ulchin Units 1, 2 CONTEMPT Model Prior to the Production of EQ Envelope Curve

    International Nuclear Information System (INIS)

    Hwang, Su Hyun; Kim, Min Ki; Hong, Soon Joon; Lee, Byung Chul; Suh, Jeong Kwan; Lee, Jae Yong; Song, Dong Soo

    2010-01-01

    The Ulchin Units 1, 2 will be refurbished with RSG (Replacement of Steam Generator) and PU (Power Uprate). The current EQ (Environmental Qualification) envelope curve should be modified according to RSG and PU. The containment P/T (Pressure/Temperature) analysis in Ulchin Units 1, 2 FSAR was done using EDF computer program PAREO6. PAREO6 uses the same assumptions as the US NRC CONTEMPT program, and the results given by both programs are in good agreement. It is utilized to determine pressure and temperature variations in a PWR containment subsequent to a reactor coolant or secondary system pipe break. But PAREO6 cannot be available to the production of EQ envelope curve, so CONTEMPT code should be used instead of PAREO6. It is essential to validate the CONTEMPT OSG (Original Steam Generator) model prior to the production of EQ envelope curve considering RSG and PU. This study has been performed to validate the CONTEMPT model of Ulchin Units 1, 2 by comparing the CONTEMPT results with the PAERO6 results in Ulchin Units 1, 2 FSAR

  14. Validation of Ulchin Units 1, 2 CONTEMPT Model Prior to the Production of EQ Envelope Curve

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Su Hyun; Kim, Min Ki; Hong, Soon Joon; Lee, Byung Chul [FNC Technology Co., SNU, Seoul (Korea, Republic of); Suh, Jeong Kwan; Lee, Jae Yong; Song, Dong Soo [KEPCO Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    The Ulchin Units 1, 2 will be refurbished with RSG (Replacement of Steam Generator) and PU (Power Uprate). The current EQ (Environmental Qualification) envelope curve should be modified according to RSG and PU. The containment P/T (Pressure/Temperature) analysis in Ulchin Units 1, 2 FSAR was done using EDF computer program PAREO6. PAREO6 uses the same assumptions as the US NRC CONTEMPT program, and the results given by both programs are in good agreement. It is utilized to determine pressure and temperature variations in a PWR containment subsequent to a reactor coolant or secondary system pipe break. But PAREO6 cannot be available to the production of EQ envelope curve, so CONTEMPT code should be used instead of PAREO6. It is essential to validate the CONTEMPT OSG (Original Steam Generator) model prior to the production of EQ envelope curve considering RSG and PU. This study has been performed to validate the CONTEMPT model of Ulchin Units 1, 2 by comparing the CONTEMPT results with the PAERO6 results in Ulchin Units 1, 2 FSAR

  15. Fault features and enrichment laws of narrow-channel distal tight sandstone gas reservoirs: A case study of the Jurassic Shaximiao Fm gas reservoir in the Zhongjiang Gas Field, Sichuan Basin

    Directory of Open Access Journals (Sweden)

    Zhongping Li

    2016-11-01

    Full Text Available The Jurassic Shaximiao Fm gas reservoir in the Zhongjiang Gas Field, Sichuan Basin, is the main base of Sinopec Southwest Oil & Gas Company for gas reserves and production increase during the 12th Five-Year Plan. However, its natural gas exploration and development process was restricted severely, since the exploration wells cannot be deployed effectively in this area based on the previous gas accumulation and enrichment pattern of “hydrocarbon source fault + channel sand body + local structure”. In this paper, the regional fault features and the gas accumulation and enrichment laws were discussed by analyzing the factors like fault evolution, fault elements, fault-sand body configuration (the configuration relationship between hydrocarbon source faults and channel sand bodies, trap types, and reservoir anatomy. It is concluded that the accumulation and enrichment of the Shaximiao Fm gas reservoir in this area is controlled by three factors, i.e., hydrocarbon source, sedimentary facies and structural position. It follows the accumulation laws of source controlling region, facies controlling zone and position controlling reservoir, which means deep source and shallow accumulation, fault-sand body conductivity, multiphase channel, differential accumulation, adjusted enrichment and gas enrichment at sweet spots. A good configuration relationship between hydrocarbon source faults and channel sand bodies is the basic condition for the formation of gas reservoirs. Natural gas accumulated preferentially in the structures or positions with good fault-sand body configuration. Gas reservoirs can also be formed in the monoclinal structures which were formed after the late structural adjustment. In the zones supported by multiple faults or near the crush zones, no gas accumulation occurs, but water is dominantly produced. The gas-bearing potential is low in the area with undeveloped faults or being 30 km away from the hydrocarbon source faults. So

  16. Castration of piglets under CO2-gas anaesthesia.

    Science.gov (United States)

    Gerritzen, M A; Kluivers-Poodt, M; Reimert, H G M; Hindle, V; Lambooij, E

    2008-11-01

    It has become common practice in pig fattening production systems to castrate young boar piglets without the use of anaesthesia. In this study, we examined whether or not CO2 gas is capable of inducing an acceptable anaesthetic state during which castration can be performed. The first step was to identify the most promising CO2/O2 mixture. Based on the results from this first experiment, a mixture of 70% CO2 + 30% O2 was chosen for further investigation as a potential anaesthetic during the castration of young piglets. Thereby, it was established whether the duration and depth of anaesthesia were acceptable for castration where the animal has to be insensible and unconscious. Physiological effects were assessed based on electroencephalogram (EEG) and electrocardiogram (ECG) measurements, blood gas values and behavioural responses. During the induction phase, the only typical behaviour the piglets exhibited when exposed to the 70/30 gas mixture was heavy breathing. All piglets (n = 25) lost consciousness after approximately 30 s according to the EEG. Heart rate decreased slowly during the induction phase, a serious drop occurred when piglets lost their posture. Immediately after this drop, the heart rate neared zero or showed a very irregular pattern. Shortly after loss of posture, most animals showed a few convulsions. None of the animals showed any reaction to castration in behaviour and/or on the EEG and ECG. On average, the piglets recovered within 59 s, i.e. EEG returned to its pre-induction pattern and piglets were able to regain a standing position. After 120 s, heart rate returned to pre-induction levels. In order to explore the usage range of CO2 concentration, 24 piglets were exposed to 60% CO2 + 20% O2 + 20% N2 for up to 30 s after loss of consciousness (as registered on EEG), and castrated after removal from the chamber. Sixteen of the 24 animals showed a reaction to the castration on the EEG. To establish the maximum time piglets survive in 70% CO2 + 30

  17. 30 CFR 256.52 - Bond requirements for an oil and gas or sulphur lease.

    Science.gov (United States)

    2010-07-01

    ... included in the Gulf of Mexico. Areawide bonds issued in the Gulf of Mexico will cover oil and gas or sulphur operations offshore the Atlantic Coast. The three areas are: (1) The Gulf of Mexico and the area... Treasury securities under this paragraph (f), you must monitor their value. If their market value falls...

  18. Recall campaign for gas bottles and banks

    CERN Multimedia

    2015-01-01

    The previous contract with gas supplier Carbagas ended on 31 March 2015. Gas bottles and banks are not a property of CERN. According to the contract terms, they can remain on CERN sites without any extra costs until 30 September 2015.    If you are using Carbagas containers (bottles and/or banks) for gas purchased between 1 April 2010 and 31 March 2015, multiple options exist: Return them to the closest gas point. Purchase them on the following basis:     Rent them on the following basis: 12 CHF/month for bottles, 144 CHF/month for banks. The recall campaign has been going on for several months already: we would like to thank everyone who has already replied to it. If you haven’t answered yet, there is still time. If you know of unused or abandoned Carbagas containers, please don’t hesitate to contact us. Thank you i...

  19. Comparative Assessment Of Natural Gas Accident Risks

    International Nuclear Information System (INIS)

    Burgherr, P.; Hirschberg, S.

    2005-01-01

    The study utilizes a hierarchical approach including (1) comparative analyses of different energy chains, (2) specific evaluations for the natural gas chain, and (3) a detailed overview of the German situation, based on an extensive data set provided by Deutsche Vereinigung des Gas- und Wasserfaches (DVGW). According to SVGW-expertise DVGW-data can be regarded as fully representative for Swiss conditions due to very similar technologies, management, regulations and safety culture, but has a substantially stronger statistical basis because the German gas grid is about 30 times larger compared to Switzerland. Specifically, the following tasks were carried out by PSI to accomplish the objectives of this project: (1) Consolidation of existing ENSAD data, (2) identification and evaluation of additional sources, (3) comparative assessment of accident risks, and (4) detailed evaluations of specific issues and technical aspects for severe and smaller accidents in the natural gas chain that are relevant under Swiss conditions. (author)

  20. 30 CFR 210.101 - Who must submit production reports?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT FORMS AND REPORTS Production Reports-Oil and Gas § 210.101 Who must submit production reports? (a... operator number. To obtain an operator number, refer to the MMS Minerals Production Reporter Handbook for... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Who must submit production reports? 210.101...