  1. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  2. Impact of multi-detector row computed tomography on the tactics of cardiovascular surgery. From qualitative evaluation to quantitative assessment

    International Nuclear Information System (INIS)

    Imagawa, Hiroshi; Kawachi, Kanji; Takano, Shinji

    2005-01-01

    We assessed the role of multi-detector row computed tomography in cardiovascular surgery. The efficacy of multi-detector row computed tomography was assessed concerning the graft patency of coronary artery bypass, arterial atheromatous degeneration, small vessel imaging, and left ventricular volume measurement. Images were reconstructed using both the volume-rendering and the maximum-intensity-profile methods. Arterial atherosclerotic degeneration was assessed by aortic wall volume and aortic calcification volume. In the assessment of bypass graft patency, multidetector row computed tomography showed a 98% correct positive ratio with sensitivity and specificity of 98% and 100%, respectively. Atheromatous degeneration showed matching results in more than 70% of cases compared with intraoperative findings. More than 92% of arterial branches with diameters of 3 mm or greater were detected by preoperative multi-detector row computed tomography images, though only 6% of branches with diameters of 2 mm or less could be visualized. There was a positive linear correlation between left ventricular volumes determined by multi-detector row computed tomography and those calculated from cine angiography. Multi-detector row computed tomography clearly visualized coronary bypass grafts and aortic arterial branches, providing detailed vascular images. Atheromatous degeneration assessed by multi-detector row computed tomography was equivalent with intraoperative findings in more than 70% of cases. Left ventricular volumes measured by multi-detector row computed tomography correlated closely with those determined by cine-angiography. Multidetector row computed tomography is an efficient and promising modality in cardiovascular surgery. (author)

  3. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  4. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Martin Lopez, Elba; Capunay, Carlos; Deviggiano, Alejandro; Vallejos, Javier; Carrascosa, Jorge

    2009-01-01

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors) [es

  5. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  6. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  7. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  8. Multi-detector row computed tomography and blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, Mariano; Pinto, Antonio; Pedrosa, Ivan; Sparano, Amelia; Romano, Luigia

    2008-01-01

    Blunt chest trauma is a significant source of morbidity and mortality in industrialized countries. The clinical presentation of trauma patients varies widely from one individual to another and ranges from minor reports of pain to shock. Knowledge of the mechanism of injury, the time of injury, estimates of motor vehicle accident velocity and deceleration, and evidence of associated injury to other systems are all salient features to provide for an adequate assessment of chest trauma. Multi-detector row computed tomography (MDCT) scanning and MDCT-angiography are being used more frequently in the diagnosis of patients with chest trauma. The high sensitivity of MDCT has increased the recognized spectrum of injuries. This new technology can be regarded as an extremely valuable adjunct to physical examination to recognize suspected and unsuspected blunt chest trauma

  9. Collateral abdominal circulation in patient with Leriche's syndrome diagnosed with 64-row multislice computed tomography (MSCT)

    International Nuclear Information System (INIS)

    Staskiewicz, G.; Drop, A.

    2008-01-01

    Leriche's syndrome results from slowly developing occlusion of the abdominal aorta. It affects mainly middle-aged males. The blood flow distal to the occlusion site is secured by collateral circulation. Signs of Leriche's syndrome include claudication, gluteal pain and impotence. The paper presents a patient with Leriche's syndrome, in whom a detailed visualization of collateral circulation was obtained with multislice computed tomography angiography. Patient underwent surgical recanalization of the aorta with an excellent result. To our knowledge, the presented case is the first description of collateral circulation in Leriche's syndrome obtained with 64-row computed tomography. (author)

  10. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  11. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  12. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  13. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  14. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  15. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    International Nuclear Information System (INIS)

    Mishra, Anuj; Bhaktarahalli, Jahnavi Narayanaswamy; Ehtuish, Ehtuish F.

    2007-01-01

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading

  16. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    International Nuclear Information System (INIS)

    Ogasawara, Yutaka; Doihara, Hiroyoshi; Shiraiwa, Misaki; Ishihara, Setsuko

    2008-01-01

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  17. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  18. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  19. Multidetector-row computed tomography management of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Yasui, Takahiro; Tanabe, Nobuhiro; Terada, Jiro

    2007-01-01

    The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pulmonary angiography and indirect venography were enrolled. Management included indication of IVC filter for patients with extensive deep venous thrombosis (DVT) in submassive or massive PE. A right ventricular to left ventricular short-axis diameter by MDCT >1.0 was judged as submassive PE. All patients were followed for 1 year. MDCT identified 50 patients with venous thromboembolism and 47 patients had acute PE: 4 were judged as massive, 14 as submassive, and 29 as non-massive by MDCT; 3 patients had DVT alone and 7 patients had caval or iliac DVT. Only 1 patient with massive PE and DVT near the right atrium died of recurrence. No other patients died of PE. Management based on MDCT pulmonary angiography combined with indirect venography is considered to be safe and reliable in patients with suspected acute PE. (author)

  20. Physics properties of non-helical scan using 320-row multi detector computed tomography

    International Nuclear Information System (INIS)

    Urikura, Atsushi; Nakaya, Yoshihiro; Kawatani, Keisuke; Kawashima, Ippei; Goto, Hironori; Ichikawa, Katsuhiro

    2012-01-01

    Recently, clinical applications utilizing 320-row multi detector computed tomography (320MDCT) have increased, and the physical image properties of 320MDCT have been more concerned. We evaluated the spatial resolution in scan plane and z-direction, image noise and low-contrast sensitivity of non-helical mode (320NH), 640 slices mode by a double slice reconstruction technology (640DS), and 64-row helical mode (64HE) by using a 320MDCT. The spatial resolution in z-direction was evaluated by the section sensitivity profile (SSP) measurement with the micro coin phantom and the contrast transfer ratio (CTR) with the 0.5-mm comb phantom. The in-plane spatial resolution of 320NH was uniform over all the slice positions. The spatial resolution in z-direction decreased from the cathode side toward the anode side. The image noise of the anode side was higher than that of the cathode side. The contrast to noise ratio as index of the low contrast sensitivity was uniform over all the slice position. The CTR of 320NH fluctuated in the z-position, and the fluctuation was improved by 640DS except for the center of rotation. (author)

  1. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  2. Complications of myocardial infarction on multidetector-row computed tomography of chest

    International Nuclear Information System (INIS)

    Raj, V.; Karunasaagarar, K.; Rudd, J.H.F.; Screaton, N.; Gopalan, D.

    2010-01-01

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  3. Complications of myocardial infarction on multidetector-row computed tomography of chest

    Energy Technology Data Exchange (ETDEWEB)

    Raj, V.; Karunasaagarar, K. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Rudd, J.H.F. [Division of Cardiovascular Medicine, University of Cambridge, Cambridge (United Kingdom); Screaton, N. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.co [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom)

    2010-11-15

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  4. Anatomic evaluation of the xiphoid process with 64-row multidetector computed tomography

    International Nuclear Information System (INIS)

    Akin, Kayihan; Kosehan, Dilek; Topcu, Adem; Koktener, Asli

    2011-01-01

    The aim of this study was to evaluate the interindividual variations of the xiphoid process in a wide adult group using 64-row multidetector computed tomography (MDCT). Included in the study were 500 consecutive patients who underwent coronary computed tomography angiography. Multiplanar reconstruction (MPR), maximum intensity projection (MIP) images on coronal and sagittal planes, and three-dimensional volume rendering (VR) reconstruction images were obtained and used for the evaluation of the anatomic features of the xiphoid process. The xiphoid process was present in all patients. The xiphoid process was deviated ventrally in 327 patients (65.4%). In 11 of these 327 patients (2.2%), ventral curving at the end of the xiphoid process resembled a hook. The xiphoid process was aligned in the same axis as the sternal corpus in 166 patients (33.2%). The tip of the xiphoid process was curved dorsally like a hook in three patients (0.6%). In four patients (0.8%), the xiphoid process exhibited a reverse S shape. Xiphoidal endings were single in 313 (62.6%) patients, double in 164 (32.8%), or triple in 23 (4.6%). Ossification of the cartilaginous xiphoid process was fully completed in 254 patients (50.8 %). In total, 171 patients (34.2%) had only one xiphoidal foramen and 45 patients (9%) had two or more foramina. Sternoxiphoidal fusion was present in 214 of the patients (42.8%). Significant interindividual variations were detected in the xiphoid process. Excellent anatomic evaluation capacity of MDCT facilitates the detection of variations of the xiphoid process as well as the whole ribcage. (orig.)

  5. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni; Scaglione, Mariano

    2008-01-01

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections

  6. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  7. Prevalence of extra-cardiac findings on studies of noninvasive coronary angiography multidetector computed tomography 64 rows

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Capunay, Carlos M.; Deviggiano, A.; Melendez, F.; Carrascosa, Jorge M.; Garcia, M.

    2007-01-01

    The aim of this paper is to show the importance of evaluating in a full form images obtained from a studio of noninvasive coronary angiography by multidetector computed tomography (AC-TCMD). 90 users of AC-TCMD were evaluated retrospectively conducted between October 2006 and April 2007 with a multidetector tomography of 64-rows(Phillips Medical Systems) . The images were reprocessed with a maximum field of vision and determined the presence of extra-cardiac findings, which were classified according to their impact on the management and treatment of patient at 3 degrees: low, medium and high grade. The studies were assessed jointly by a cardiologist and a radiologist qualified for cardiac and corporal evaluation. Extra-cardiac findings were identified in 58 patients. There were 38 patients with findings of low grade, 31 medium grade and 1 high grade. It was recommended to 16 patients its monitoring by images on reasonable period of time [es

  8. Automatic assessment of coronary artery calcium score from contrast-enhanced 256-row coronary computed tomography angiography.

    Science.gov (United States)

    Rubinshtein, Ronen; Halon, David A; Gaspar, Tamar; Lewis, Basil S; Peled, Nathan

    2014-01-01

    The coronary artery calcium score (CS), an independent predictor of cardiovascular events, can be obtained from a stand-alone nonenhanced computed tomography (CT) scan (CSCT) or as an additional nonenhanced procedure before contrast-enhanced coronary CT angiography (CCTA). We evaluated the accuracy of a novel fully automatic tool for computing CS from the CCTA examination. One hundred thirty-six consecutive symptomatic patients (aged 59 ± 11 years, 40% female) without known coronary artery disease who underwent both 256-row CSCT and CCTA were studied. Original scan reconstruction (slice thickness) was maintained (3 mm for CSCT and 0.67 mm for CCTA). CS was computed from CCTA by an automatic tool (COR Analyzer, rcadia Medical Imaging, Haifa, Israel) and compared with CS results obtained by standard assessment of nonenhanced CSCT (HeartBeat CS, Philips, Cleveland, Ohio). We also compared both methods for classification into 5 commonly used CS categories (0, 1 to 10, 11 to 100, 101 to 400, >400 Agatston units). All scans were of diagnostic quality. CS obtained by the COR Analyzer from CCTA classified 111 of 136 (82%) of patients into identical categories as CS by CSCT and 24 of remaining 25 into an adjacent category. Overall, CS values from CCTA showed high correlation with CS values from CSCT (Spearman rank correlation = 0.95, p automatically computed from 256-row CCTA correlated highly with standard CS values obtained from nonenhanced CSCT. CS obtained directly from CCTA may obviate the need for an additional scan and attendant radiation. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  10. Prospective Electrocardiogram-Gated Multidetector Row Computed Tomography Coronary Angiography. Analysis of Quality Image and Radiation Dose

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Deviggiano, A.; Tajer, C.D.; Vallejos, J.; Goldsmit, A.; Garcia, M.J.

    2009-01-01

    Multidetector row computed tomography coronary angiography (MDCT-CA) has become a useful diagnostic tool for the direct quantification of coronary stenosis, for identifying coronary anomalies and for the assessment of coronary artery bypass grafts. Despite its clinical value has been questioned due to the effective radiation dose (ERD) received by each patient, radiation exposure is similar to other studies. However, different strategies are permanently tested in order to reduce the ERD maintaining adequate and diagnostic image quality. Objectives: To determine the image quality and effective radiation dose (ERD) of prospective electrocardiogram-gated multidetector row computed tomography coronary angiography (PMDCTCA) (the x-ray beam is turned on for only a short portion of diastole) compared to retrospective ECG gating (RMDCTCA) (the x-ray beam is turned on throughout the cardiac cycle) and a preliminary approach of its diagnostic accuracy compared to digital invasive coronary angiography (CA). Material and Methods: Fifty consecutive patients with suspected coronary artery disease and sinus rhythm were evaluated with PMDCT-CA and compared to a control group who underwent RMDCTCA. Image quality was analyzed by two reviewers. Interobserver concordance and ERD were determined. The diagnostic accuracy of PMDCT-CA compared to CA to detect coronary artery stenosis > 50% was assessed in 30 patients. Results: There were no significant differences in the image quality between both groups. Agreement between the reviewers for segment image quality scores was k = 0.92. Mean ERD was 3.5 mSv for PMDCT-CA compared to 9.7 and 12.9 mSv for RMDCT-CA with and without tube current modulation, respectively. Individual analysis including all segments showed that the sensitivity, specificity, positive predictive value and negative predictive value of PMDCT-CA for the detection of coronary stenosis were 94.74%, 81.82%, 90% and 90%, respectively. Conclusion: Our initial experience

  11. Impact of reduced-radiation dual-energy protocols using 320-detector row computed tomography for analyzing urinary calculus components: initial in vitro evaluation.

    Science.gov (United States)

    Cai, Xiangran; Zhou, Qingchun; Yu, Juan; Xian, Zhaohui; Feng, Youzhen; Yang, Wencai; Mo, Xukai

    2014-10-01

    To evaluate the impact of reduced-radiation dual-energy (DE) protocols using 320-detector row computed tomography on the differentiation of urinary calculus components. A total of 58 urinary calculi were placed into the same phantom and underwent DE scanning with 320-detector row computed tomography. Each calculus was scanned 4 times with the DE protocols using 135 kV and 80 kV tube voltage and different tube current combinations, including 100 mA and 570 mA (group A), 50 mA and 290 mA (group B), 30 mA and 170 mA (group C), and 10 mA and 60 mA (group D). The acquisition data of all 4 groups were then analyzed by stone DE analysis software, and the results were compared with x-ray diffraction analysis. Noise, contrast-to-noise ratio, and radiation dose were compared. Calculi were correctly identified in 56 of 58 stones (96.6%) using group A and B protocols. However, only 35 stones (60.3%) and 16 stones (27.6%) were correctly diagnosed using group C and D protocols, respectively. Mean noise increased significantly and mean contrast-to-noise ratio decreased significantly from groups A to D (P calculus component analysis while reducing patient radiation exposure to 1.81 mSv. Further reduction of tube currents may compromise diagnostic accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. 320-row detector computed tomography angiography findings of a case with multiple

    International Nuclear Information System (INIS)

    Akay, S.; Bozlar, U.; Demirkol, S.; Tasar, M.

    2012-01-01

    Full text: Introduction: Computed tomography angiography (CTA) with three-dimensional imaging capability is a very reliable imaging modality for the evaluation of the coronary arteries. Objectives and tasks: To discuss the 320-row detector CTA findings of a case with multiple coronary artery course anomaly. Materials and methods: A 46-year-old man with palpitation, admitted to Cardiology department of our hospital. On electrocardiography, polymorphic ventricular early beats were observed. The patient was referred to Radiology department for CTA examination in terms of probable coronary artery anomaly. Results: On CTA, left main coronary artery was short. The bridging causes nearly 75% luminal stenosis was observed in the middle part of left descending artery. Circumflex artery was continuing as the first obtuse margin and this branch was separating to four branches in the middle part. They were coursing subepicardially in the middle and distal part. Right main coronary artery has also subepicardial course in its middle and distal part. Conclusion: Myocardial bridging is not a rare situation in routine clinical practice. But bridging in all of the three coronary arteries is very uncommon. Multidetector CTA is an effective and non-invasive imaging modality for understanding the normal anatomy and detecting the congenital anomalies of the coronary arteries

  13. Enhanced multidetector-row computed tomography (MDCT) in the diagnosis of acute appendicitis and its severity

    International Nuclear Information System (INIS)

    Miki, Tesshou; Ogata, Seiji; Uto, Mitsunobu; Nakazono, Toshihiro; Urata, Miyuki; Ishibe, Ryouhei; Shinyama, Shin; Nakajo, Masayuki

    2005-01-01

    The purpose of this study was to examine the accuracy of enhanced multidetector-row computed tomography (MDCT) in diagnosing acute appendicitis and its severity. Contrast-enhanced MD-CT 3.5 mm thick images of 23 control patients (A), and 64 patients with surgically proven acute appendicitis including 8 catarrhal (B), 28 phiegmonous (C), and 28 gangrenous (D) appendicitis patients were respectively analyzed. The number of observed major computed tomography (CT) findings for each patient group were as follows: enlarged (≥6 mm in maximum diameter) appendix (A: 5, B: 8, C: 28, D: 28), enhancement of the appendiceal wall; hyper (A: 3, B: 8, C: 27, D: 20), iso (A: 15, B: 0, C: 1, D: 2), hypo (A-C: 0, D: 4), and patched (A-C: 0, D: 2) enhancement, appendicolith (A, B: 0, C: 7, D: 13), dirty fat sign (A: 3, B: 1, C: 21, D: 28), localized ascites (A: 2, B: 0, C: 2, D: 11), and abscess formation (A-C: 0, D: 5). From the combinations of these findings, we could differentiate acute appendicitis from the control normal appendix with an accuracy of 99% and could diagnose the severity of acute appendicitis with accuracies of 92% for catarrhal appendicitis, 84% for phlegmonous appendicitis, and 92% for gangrenous appendicitis. We could also visually reconstruct the entire forms and positions of the appendices from the successive CT findings because of the high-resolution thin-slice MDCT images. MDCT is highly accurate in the diagnosis of acute appendicitis and its severity. (author)

  14. Defining Anatomic Variants of the Coronary Artery in Taiwanese Subjects Using 64-Multidetector-Row Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hung-Jung Wang

    2007-10-01

    Full Text Available The newly developed 64-multidetector-row computed tomography (MDCT prompted us to evaluate coronary angiography using this noninvasive method. We reviewed 281 images of MDCT coronary angiography in Taiwanese. The origins of the coronary arteries were identified from the luminal aspect of the aorta. We described them as seen from the aortic sinus looking toward the cardiac ventricle. The sinus facing the left ventricle was designated sinus 1, and that facing the right ventricle was designated sinus 2. Anatomic variants of the coronary artery were divided into five types according to the structure of the left anterior descending artery, right coronary artery, and left circumflex artery. Of the 281 patients, 275 (97.9% had the type I variant in which the right coronary artery originated from sinus 2. MDCT provides advantages in defining anatomic variation and helps in the planning of clinical therapy or surgery.

  15. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  16. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  17. Whole-heart 320-row computed tomography. Reduction of radiation dose via prior coronary calcium scanning

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, E.; Dewey, M. [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-01-15

    Purpose: The whole heart can be scanned in one rotation using 320-row coronary computed tomography angiography (CCTA), which covers up to 16 cm. Since most hearts are smaller, the total radiation dose may be reduced by adjusting the CCTA range to the individual heart size defined on a low-dose calcium scan (CACS). Materials and Methods: Forty-five patients with suspected coronary artery disease (13 women, 32 men; mean 61 {+-} 10 years) underwent CCTA preceded by low-dose CACS on a 320-row scanner (Aquilion ONE, Toshiba; 0.35 s gantry rotation, 120 kV, 350 - 450 mA) with 16-cm z-axis coverage (120 kV, 150 mA). The subsequent CCTA was performed over an adjusted scan range calculated as the individual heart size on CACS ({+-} 1 cm above and below). The total radiation dose of 16-cm CACS and the individually adjusted CCTA was compared with that of a calculated single CCTA using full 16-cm z-axis coverage. Results: CCTA could be performed with a reduced scan length in the z-axis in all patients. None of the scans had to be performed over the whole range of 16 cm. The adjusted scan length was 14 cm in 2 patients, 12.8 cm in 3 patients, and 12 cm in 40 patients. The effective CCTA scan range was 12.1 {+-} 0.5 cm based on mean individual heart sizes of 9.6 {+-} 1.1 cm. The mean total effective radiation dose of the entire cardiac CT examination (individually adapted CCTA and CACS) was significantly smaller than the exposure calculated for 16-cm CCTA without CACS (8.5 {+-} 4.7 vs. 9.1 {+-} 6.0 mSv, p = 0.006). The dose reduction was most relevant in patients with heart rates above 65 beats/min (n = 10) in whom 2 or 3 heartbeats were necessary for CCTA (17.7 {+-} 6.5 vs. 21.1 {+-} 8.4 mSv, p = 0.001). Conclusion: 320-row CCTA with an individually adjusted scan range based on prior CACS significantly reduces the radiation exposure compared with full 16-cm CCTA. (orig.)

  18. Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

    Science.gov (United States)

    Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae

    2010-03-01

    Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.

  19. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao; Failla, Bruna Bonaventura

    2013-01-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  20. Imaging of peripheral arteries by 16-slice computed tomography angiography: a valuable tool

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2007-01-01

    To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral vascular disease. Thirty three patients underwent multislice computed tomography angiography (MSCTA) of the upper or the lower limb on multislice (16-slice) CT scanner between November 2004 and July 2005 in the Department of Radiology, National Organ Transplant Center, Tripoli, Libya. The findings were retrospectively compared with the surgical outcome in cases of trauma with suspected arterial injuries; or color Doppler correlation was obtained, for patients of peripheral vascular disease. Multislice computed tomography angiography allows a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In 23 cases of peripheral vascular diseases, MSCTA adequately demonstrated the presence of any stenosis or occlusion, its degree and extent, the presence of collaterals and distal reformation if any; the presence of plaques. Our experience of computed tomography angiography with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries; and as a useful screening modality in cases of peripheral vascular disease for diagnosis and for grading. (author)

  1. Influence of gating phase selection on the image quality of coronary arteries in multidetector row computed tomography

    International Nuclear Information System (INIS)

    Laskowska, K.; Marzec, M.; Serafin, Z.; Nawrocka, E.; Lasek, W.; WWisniewska-Szmyt, J.; Kubica, J.

    2005-01-01

    Motion artifacts caused by cardiac movement disturb the imaging of coronary arteries with multidetector-row spiral computed tomography. The aim of this study was to determine the phase of the heart rate which provides the best quality of coronary artery imaging in retrospective ECG-gated CT. Although 75% is usually the best reconstruction phase, the optimal phase should be established individually for the patient, artery, segment, and type of tomograph for the best imaging quality. Forty-five cardiac CT angiograms of 26 patients were retrospectively evaluated. The examinations were performed with a 4-detector-row tomograph. ECG-gated retrospective reconstructions were relatively delayed at 0%, 12.5%, 25%, 37.5%, 50%, 62.5%, 75%, and 87.5% of the cardiac cycle. Selected coronary arteries of the highest diagnostic quality were estimated in the eight phases of the cardiac cycle. Only arteries of very high image quality were selected for analysis: left coronary artery trunks (44 cases, incl. 37 stented), anterior interventricular branches (36, incl. 3 stented), circumflex branches (16), right coronary rtery branches (23), and posterior interventricular branches (4). The reconstruction phase had a statistically significant impact on the quality of imaging (p < 0.0003). Depending on the case, optimal imaging was noted in various phases, except in the 12.5 % phase. The 75% phase appeared to be the best of all those examined (p < 0.05), both in the group of arteries without stents (p < 0.0006) and in those stented (p < 0.05). In some cases of repeated examinations the best phases differed within the same patient. (author)

  2. Limitations of 64-Detector-Row Computed Tomography Coronary Angiography: Calcium and Motion but not Short Experience

    International Nuclear Information System (INIS)

    Mir-Akbari, H.; Ripsweden, J.; Jensen, J.; Pichler, P.; Sylven, C.; Cederlund, K.; Rueck, A.

    2009-01-01

    Background: Recently, 64-detector-row computed tomography coronary angiography (CTA) has been introduced for the noninvasive diagnosis of coronary artery disease. Purpose: To evaluate the diagnostic capacity and limitations of a newly established CTA service. Material and Methods: In 101 outpatients with suspected coronary artery disease, 64-detector-row CTA (VCT Lightspeed 64; GE Healthcare, Milwaukee, WI., USA) was performed before invasive coronary angiography (ICA). The presence of >50% diameter coronary stenosis on CTA was rated by two radiologists recently trained in CTA, and separately by an experienced colleague. Diagnostic performance of CTA was calculated on segment, vessel, and patient levels, using ICA as a reference. Segments with a proximal reference diameter <2 mm or with stents were not analyzed. Results: In 51 of 101 patients and 121 of 1280 segments, ICA detected coronary stenosis. In 274 of 1280 (21%) segments, CTA had non-diagnostic image quality, the main reasons being severe calcifications (49%), motion artifacts associated with high or irregular heart rate (45%), and low contrast opacification (14%). Significantly more women (43%) had non-diagnostic scans compared to men (20%). A heart rate above 60 beats per minute was associated with significantly more non-diagnostic patients (38% vs. 18%). In the 1006 diagnostic segments, CTA had a sensitivity of 78%, specificity of 95%, positive predictive value (PPV) of 54%, and negative predictive value (NPV) of 98% for detecting significant coronary stenosis. In 29 patients, CTA was non-diagnostic. In the remaining 72 patients, sensitivity was 100%, specificity 65%, PPV 79%, and NPV 100%. The use of a more experienced CTA reader did not improve diagnostic performance. Conclusion: CTA had a very high negative predictive value, but the number of non-diagnostic scans was high, especially in women. The main limitations were motion artifacts and vessel calcifications, while short experience in CTA did not

  3. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography.

    Science.gov (United States)

    Min, James K; Swaminathan, Rajesh V; Vass, Melissa; Gallagher, Scott; Weinsaft, Jonathan W

    2009-01-01

    The assessment of coronary stents with present-generation 64-detector row computed tomography scanners that use filtered backprojection and operating at standard definition of 0.5-0.75 mm (standard definition, SDCT) is limited by imaging artifacts and noise. We evaluated the performance of a novel, high-definition 64-slice CT scanner (HDCT), with improved spatial resolution (0.23 mm) and applied statistical iterative reconstruction (ASIR) for evaluation of coronary artery stents. HDCT and SDCT stent imaging was performed with the use of an ex vivo phantom. HDCT was compared with SDCT with both smooth and sharp kernels for stent intraluminal diameter, intraluminal area, and image noise. Intrastent visualization was assessed with an ASIR algorithm on HDCT scans, compared with the filtered backprojection algorithms by SDCT. Six coronary stents (2.5, 2.5, 2.75, 3.0, 3.5, 4.0mm) were analyzed by 2 independent readers. Interobserver correlation was high for both HDCT and SDCT. HDCT yielded substantially larger luminal area visualization compared with SDCT, both for smooth (29.4+/-14.5 versus 20.1+/-13.0; P<0.001) and sharp (32.0+/-15.2 versus 25.5+/-12.0; P<0.001) kernels. Stent diameter was higher with HDCT compared with SDCT, for both smooth (1.54+/-0.59 versus1.00+/-0.50; P<0.0001) and detailed (1.47+/-0.65 versus 1.08+/-0.54; P<0.0001) kernels. With detailed kernels, HDCT scans that used algorithms showed a trend toward decreased image noise compared with SDCT-filtered backprojection algorithms. On the basis of this ex vivo study, HDCT provides superior detection of intrastent luminal area and diameter visualization, compared with SDCT. ASIR image reconstruction techniques for HDCT scans enhance the in-stent assessment while decreasing image noise.

  4. Accessory oral cavity associated with duplication of the tongue and the mandible in a newborn: a rare case of Diprosopus. Multi-row detector computed tomography diagnostic role.

    Science.gov (United States)

    Morabito, Rosa; Colonna, Michele R; Mormina, Enricomaria; Stagno d'Alcontres, Ferdinando; Salpietro, Vincenzo; Blandino, Alfredo; Longo, Marcello; Granata, Francesca

    2014-12-01

    Craniofacial duplication is a very rare malformation. The phenotype comprises a wide spectrum, ranging from partial duplication of few facial structures to complete dicephalus. We report the case of a newborn with an accessory oral cavity associated to duplication of the tongue and the mandible diagnosed by multi-row detector Computed Tomography, few days after her birth. Our case of partial craniofacial duplication can be considered as Type II of Gorlin classification or as an intermediate form between Type I and Type II of Sun classification. Our experience demonstrates that CT scan, using appropriate reconstruction algorithms, permits a detailed evaluation of the different structures in an anatomical region. Multi-row CT scan is also the more accurate diagnostic procedure for the pre-surgical evaluation of craniofacial malformations. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Focal Stenosis in Right Upper Lobe Bronchus in a Recurrently Wheezing Child Sequentially Studied by Multidetector-row Spiral Computed Tomography and Scintigraphy

    Directory of Open Access Journals (Sweden)

    I-Chen Chen

    2009-12-01

    Full Text Available Lower respiratory tract infections associated with wheezing are not uncommon in infants and young children. Among the wheezing-associated disorders, allergic etiologies are more commonly encountered than anatomic anomalies. We present a 3-year-old girl with a sudden attack of asthmatic symptoms including dyspnea, cyanosis and diffuse wheezing. Based on a history of choking, and atelectasis in the right upper lobe detected by chest films, flexible tracheobronchoscopy was arranged and incidentally detected a stenotic orifice in the right upper lobe bronchus. Multidetector-row spiral computed tomography and pulmonary scintigraphy subsequently also disclosed the focal stenosis. She suffered from recurrent wheezing, pneumonia and lung atelectasis during 1 year of follow-up. We emphasize the diagnosis, clinical course and management of focal stenosis in the right upper lobe bronchus.

  6. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  7. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  8. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Chou [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tsai, Shih-Hung [Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Chang, Wei-Kuo [Division of Gasteroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Liu, Chang-Hsien [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tung, Ho-Jui [Department of Healthcare Administration, Asia University, Taichung, Taiwan (China); Hsieh, Chung-Bao [Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Huang, Guo-Shu; Hsu, Hsian-He [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Yu, Chih-Yung, E-mail: chougo2002@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China)

    2011-11-15

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  9. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chang, Wei-Chou; Tsai, Shih-Hung; Chang, Wei-Kuo; Liu, Chang-Hsien; Tung, Ho-Jui; Hsieh, Chung-Bao; Huang, Guo-Shu; Hsu, Hsian-He; Yu, Chih-Yung

    2011-01-01

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  10. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  11. Computed tomography with multidetectors in the diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Lombo, Bernardo; Carvajal, Codos A; Tafur, Monica; Gomez, Rafael

    2007-01-01

    Coronary angiography that uses multislice spiral computed tomography is a noninvasive technique for the detection of coronary stenosis that has had significant improvements in recent years. The introduction of 16 and 64 row scanners, the development of synchronized scanning electrocardiogram and better reconstruction techniques permit higher spatial and temporal resolution that allows better identification of coronary plaques and significant obstructive coronary lesions. In the next years Multislice spiral computed tomography will continue maturing and it will become a useful non invasive diagnostic imaging tool for the diagnosis of coronary disease and will be integrated to the cardiologic management protocols. Our next review will be focused on the basic and technical aspects of the scanner, diagnostic performance and clinical applications of this new technology

  12. Development of a rapid multi-line detector for industrial computed tomography

    International Nuclear Information System (INIS)

    Nachtrab, Frank; Firsching, Markus; Hofmann, Thomas; Uhlmann, Norman; Neubauer, Harald; Nowak, Arne

    2015-01-01

    In this paper we present the development of a rapid multi-row detector is optimized for industrial computed tomography. With a high frame rate, high spatial resolution and the ability to use up to 450 kVp it is particularly suitable for applications such as fast acquisition of large objects, inline CT or time-resolved 4D CT. (Contains PowerPoint slides). [de

  13. Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Hara, Takanori; Urikura, Atsushi; Ichikawa, Katsuhiro; Hoshino, Takashi; Nishimaru, Eiji; Niwa, Shinji

    2016-04-01

    To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/P=0.285/1.5) and 0.074s (R/P=0.285/3.2), and the maximum TR values of the 64×0.5- and 160×0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/P=0.275/1.375) and 0.195s (R/P=0.3/0.6), respectively. Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

    Science.gov (United States)

    Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki

    2013-01-01

    This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; Ppannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

  15. Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Rothfuss, Julia K.; Fenchel, Michael; Stauder, Norbert; Kuettner, Axel; Miller, Stephan; Claussen, Claus D.; Kopp, Andreas F.; Schroeder, Stephen; Burgstahler, Christof; Franow, Andreas; Kuzo, Ronald S.

    2006-01-01

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI. (orig.)

  16. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  17. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    OpenAIRE

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki

    2015-01-01

    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images fr...

  18. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  19. Multidetector row computed tomography noninvasively assesses coronary reperfusion after thrombolytic therapy in patients with ST elevation myocardial infarction

    International Nuclear Information System (INIS)

    Shin, Dong-Il; Won, Yoo-Dong; Chang, Kiyuk

    2006-01-01

    The study objective was to assess the efficacy of 16-slice multidetector row computed tomography (MDCT) in estimating residual stenosis and successful reperfusion after thrombolysis in patients with ST-elevation myocardial infarction (STEMI). A total of 31 patients with STEMI underwent MDCT scanning within 6 h (mean 4.6±1.1) after thrombolysis and the results for detection of significant residual stenosis and distal flow of the infarct-related artery were compared with those from conventional coronary angiography (CCAG) performed within 24 h (mean 12.1±5.6) after the MDCT scan. Successful reperfusion was defined as Thrombolysis In Myocardial Infarction flow 2 or 3 on CCAG and full contrast enhancement of the distal artery landmarks on MDCT. A final analysis was performed using 24 patients (312 segments). MDCT had a positive predictive value of 73.3% and a negative predictive value of 95.1% for detecting significant residual stenosis. It accurately estimated 17 of 18 patients (94.4%) with successful reperfusion and 5 of 6 (83.3%) with failed reperfusion on the basis of comparison with CCAG. MDCT demonstrated high accuracy not only for the detecting residual stenosis, but also for assessing successful reperfusion after thrombolytic therapy in patients with STEMI. (author)

  20. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    International Nuclear Information System (INIS)

    Calisir, C.; Can, C.; Kebapci, M.

    2007-01-01

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis

  1. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  2. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  3. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  4. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  5. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  6. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    International Nuclear Information System (INIS)

    Tanis, Wilco; Sucha, Dominika; Habets, Jesse; Laufer, Ward; Chamuleau, Steven; Herwerden, Lex.A. van; Symersky, Petr; Budde, Ricardo P.J.

    2015-01-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  7. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  9. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  10. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  11. Role of enhanced multi-detector-row computed tomography before urgent endoscopy in acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Miyaoka, Youichi; Amano, Yuji; Ueno, Sayaka; Izumi, Daisuke; Mikami, Hironobu; Yazaki, Tomotaka; Okimoto, Eiko; Sonoyama, Takayuki; Ito, Satoko; Fujishiro, Hirofumi; Kohge, Naruaki; Imaoka, Tomonori

    2014-04-01

    Multi-detector-row computed tomography (MDCT) has been reported to be a potentially useful modality for detection of the bleeding origin in patients with acute upper massive gastrointestinal (GI) bleeding. The purpose of this study is to investigate the efficacy of MDCT as a routine method for detecting the origin of acute upper GI bleeding prior to urgent endoscopy. Five hundred seventy-seven patients with acute upper GI bleeding (514 nonvariceal patients, 63 variceal patients) who underwent urgent upper GI endoscopy were retrospectively analyzed. Patients were divided into three groups: enhanced MDCT, unenhanced MDCT, and no MDCT before endoscopy. The diagnostic accuracy of MDCT for detection of the bleeding origin was evaluated, and the average procedure times needed to endoscopically identify the bleeding origin were compared between groups. Diagnostic accuracy among endoscopists was 55.3% and 14.7% for the enhanced MDCT and unenhanced MDCT groups, respectively. Among nonvariceal patients, accuracy was 50.2% in the enhanced MDCT group, which was significantly better than that in the unenhanced MDCT group (16.5%). In variceal patients, accuracy was significantly better in the enhanced MDCT group (96.4%) than in the unenhanced MDCT group (0.0%). These accuracies were similar to those achieved by expert radiologists. The average procedure time to endoscopic detection of the bleeding origin in the enhanced MDCT group was significantly faster than that in the unenhanced MDCT and no-MDCT groups. Enhanced MDCT preceding urgent endoscopy may be an effective modality for the detection of bleeding origin in patients with acute upper GI bleeding. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  12. Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

    Directory of Open Access Journals (Sweden)

    Atif N Khan

    2014-01-01

    Full Text Available Objectives: This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA following decennial screening guidelines. Material and Methods: Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from prior published literature for the 64 row CT scanner were compared with data from our study using 320 row detector CT scanner. Data from the 64 row and the 320 row detector CT scanners was used to determine lifetime attributable risks (LAR of cancer based on the biological effects of ionizing radiation (BEIR VII report. Results: The relative reduction of LAR (% for 50-, 60-, and 70-year-old patients undergoing scanning with the 320 row detector CT scanner was 30% lower for lung, and more than 50% lower for female breast when compared with results from 64 row detector CT scanner. The use of 320 row detector CT would result in a combined cumulative cancer incidence of less than 1/500 for breast in women and less than 1/1000 for lung in men; By comparison, this is much lower than other more common risk factors: 16-fold for lung cancer in persistent smokers, 2-fold for breast cancer with a first degree family member history of breast cancer, and 10-fold for thyroid cancer with a family member with thyroid cancer. Decennial screening would benefit at least 355,000 patients from sudden cardiac death each year, 94% of whom have significant coronary artery disease, with at least one stenosis >75%. LAR for thyroid cancer was negligible for both scanners. Conclusion: Lung and female breast LAR reductions with 320 row detector compared with 64 row detector CT are substantial, and the benefits would outweigh increased cancer risks with decennial screening in the age group of 50-70 years.

  13. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  14. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    Tokue, Hiroyuki; Tokue, Azusa; Tsushima, Yoshito

    2012-01-01

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  15. Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Hyoung Jung; Lee, Dong Ho; Lim, Joo Won; Ko, Young Tae

    2009-01-01

    Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  17. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Grangeat, P.

    2003-01-01

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  20. Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Okumoto, Tadayuki; Yamada, Takayuki; Sato, Akihiro

    2009-01-01

    Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. Vascular invasion is considered to be the degree of tumor contiguity to the hepatic arteries and portal vein and was graded by CT. The longitudinal extension was correctly diagnosed in 14 patients (77.8%). Hepatic artery invasion was correctly diagnosed in 17 patients with sensitivity of 100% and specificity of 90%, respectively. Portal vein invasion was correctly diagnosed in 47 of 51 branches with sensitivity and specificity of 92.3% and 90.2%, respectively. Multiplanar reconstructed images contributed to the correct diagnosis for both vascular encasement and longitudinal tumor extension. In conclusion, MDCT is useful in preoperative evaluation of hilar cholangiocarcinoma, especially when combined with multiplanar reconstructed images. (author)

  1. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    International Nuclear Information System (INIS)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung

    2008-01-01

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  2. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  3. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  4. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  5. Dynamic X-ray computed tomography; Tomographie dynamique a rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Grangeat, P

    2003-07-01

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  6. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  7. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  8. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T.; Scholten, Marcoen F.; Jordaens, Luc J.

    2005-01-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1±2.4 preprocedural versus 18.6±2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2±0.2 versus 1.2±0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1±2.5 mm versus 16.5±2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  12. Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing.

    Science.gov (United States)

    Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria

    2018-01-01

    Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  13. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Sekine, Takako; Kodama, Takahide; Kondo, Takeshi

    2010-01-01

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  14. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    Directory of Open Access Journals (Sweden)

    Tokue Hiroyuki

    2012-12-01

    Full Text Available Abstract Background We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP using routine 64 multidetector-row computed tomography (MDCT data in order to plan for the implantation of an intra-arterial hepatic port system. Methods A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward. Results The median branching angle was (median ± standard deviation 135 ± 23 (range, 51–174 degrees. The branching was upward in 77 patients (7% and downward in 1,027 patients (93%. The branching was downward with an angle of 120 to150 degrees in most patients (n = 613. The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%. A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. Conclusions The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery.

  15. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  16. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  19. Gadolinium Ethoxybenzyl Diethylenetriamine Pentaacetic Acid (Gd-EOB-DTPA)-Enhanced Magnetic Resonance Imaging and Multidetector-Row Computed Tomography for the Diagnosis of Hepatocellular Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ye, Feng; Liu, Jun; Ouyang, Han

    2015-08-01

    The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.

  20. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  2. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  4. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  5. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  6. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  7. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  8. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  9. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  10. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  11. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  12. Multidetector computer tomography in the pancreatic adenocarcinoma assessment: an update

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    2016-11-01

    Full Text Available Abstract Ductal adenocarcinoma of the pancreas is one of the most aggressive forms of cancer, with only a minority of cases being resectable at the moment of their diagnosis. The accurate detection and characterization of pancreatic carcinoma is very important for patient management. Multidetector-row computed tomography (MDCT has become the cross-sectional modality of choice in the diagnosis, staging, treatment planning, and follow-up of patients with pancreatic tumors. However, approximately 11% of ductal adenocarcinomas still remain undetected at MDCT because of the lack of attenuation gradient between the lesion and the adjacent pancreatic parenchyma. In this systematic literature review we investigate the current evolution of the CT technique, limitations, and perspectives in the evaluation of pancreatic carcinoma.

  13. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  14. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  15. Accuracy of multidetector row computed tomography for the diagnosis of acute bowel ischemia in a non-selected study population

    International Nuclear Information System (INIS)

    Wiesner, Walter; Hauser, Andreas; Steinbrich, Wolfgang

    2004-01-01

    The diagnostic accuracy of multidetector row computed tomography for the prospective diagnosis of acute bowel ischemia in the daily clinical routine was analyzed. Two hundred ninety-one consecutive patients with an acute or subacute abdomen, examined by MDCT over a time period of 5 months, were included in the study. All original CT diagnoses made during the daily routine by radiological generalists were compared to the final diagnoses made by using all available medical information from endoscopies, surgical interventions, autopsies and follow-up. Finally, all CT examinations of patients with an initial CT diagnosis or a final diagnosis of bowel ischemia were reread by a radiologist specialized in abdominal imaging in order to analyze the CT findings and the reasons for initially false negative or false positive CT readings. Twenty-four patients out of 291 (8.2%) had acute bowel ischemia. The age of affected patients ranged from 50 to 94 years (mean age: 75.7 years). Eleven patients were male, and 13 female. Reasons for acute bowel ischemia were: arterio-occlusive (n=11), non-occlusive (n=5), strangulation (n=2), over-distension (n=3) and radiation (n=3). The prospective sensitivity, specificity, PPV and NPV of MDCT for the diagnosis of acute bowel ischemia in the daily routine were 79.17, 98.51, 90.48 and 98.15%. MDCT reaches a similarly high sensitivity in diagnosing acute bowel as angiography. Furthermore, it has the advantage of being helpful in most of its clinical differential diagnoses and of being less invasive with the consecutive possibility of being used earlier in the diagnostic process with all the resulting positive effects on the patients prognosis. Therefore, nowadays MDCT should probably be used as the first step imaging modality of choice in patients with suspected acute bowel ischemia. (orig.)

  16. Four-channel multidetector-row computed tomography in the evaluation of facial fractures - optimized parameters for acquisition and multiplanar reformation

    International Nuclear Information System (INIS)

    Omid, P. M.

    2002-08-01

    The first part of this thesis is designed to give the reader a comprehensive survey on the complex basic principles of computed tomography (CT), from the early beginning to the recent development of multidetector-row CT (MD-CT). Attention is focused on imaging of trauma in general and on imaging of facial fractures in particular. The second part of this thesis describes a clinical study performed to optimize acquisition protocols and multiplanar reformation (MPR) algorithms for the evaluation of facial fractures using MD-CT, which has not been yet described in literature. For this study, a cadaver head with artificial blunt facial trauma was examined using a 4-channel MD-CT scanner. The influence of acquisition parameters (collimation: 2x0.5 mm/4x1 mm/4x2.5 mm; tube current: 120 mAs/90 mAs/60 mAs), image reconstruction algorithms (standard vs. ultra-high resolution (UHR) modes; reconstructed slice thicknesses: 0.5 mm/1 mm/3 mm; increment: 0.3 mm/0.6 mm/1.5 mm), and reformation algorithms (slice thicknesses: 0.5 mm/1 mm/3 mm; overlap: 0.5 mm/1 mm/3 mm) on detectability of facial fractures in MPRs with MD-CT was analyzed. Effects of algorithms and parameters on image noise, artifacts and delineation of soft tissues were evaluated. The results of this study reliably demonstrate that fracture detection was significantly higher with thin MPRs (0.5/0.5 mm, 1/0.5 mm, 1/1 mm) (p = 0 .014) acquired with 2x0.5 mm collimation (p = 0 .046), in UHR mode (p .0005) with 120 mAs (p = 0 .025). Inter-observer variability showed very good agreement (κ > = 0 .942). Non-UHR mode, lower mAs and thick MPRs (3/0.5 mm, 3/1 mm, 3/0.5 mm) showed significantly decreased detectability. (author)

  17. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  18. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  19. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  20. Comparison of the multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and extrahepatic cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yata, M.; Suzuki, K.; Furuhashi, N.; Kawakami, K.; Kawai, Y.; Naganawa, S.

    2016-01-01

    Aim: To compare the multidetector-row computed tomography (MDCT) findings of IgG4-related sclerosing cholangitis (IgG4-SC) and extrahepatic cholangiocarcinoma (EH-CCA). Materials and methods: Two radiologists who had no knowledge of the patients' clinical information retrospectively evaluated the CT findings of patients with IgG4-SC (n=33) and EH-CCA (n=39) on a consensus basis. Another radiologist measured the biliary lesions. IgG4-SC was diagnosed using the Japan Biliary Association criteria (2012) or the Mayo Clinic's HISORt criteria. EH-CCA was diagnosed based on surgical findings. Results: Compared with EH-CCA, IgG4-SC exhibited the following findings significantly more frequently: (a) wall thickening alone, (b) concentric wall thickening, (c) smooth inner margins, (d) homogeneous attenuation in the arterial phase, (e) a lesion involving the intrapancreatic bile duct, (f) smooth outer margins, (g) fully visible lumen, (h) a funnel-shaped proximal bile duct, (i) skip lesions, and (j) abnormal pancreatic findings. Conversely, (k) dual-layered attenuation in all phases was significantly more common in EH-CCA. The specificity values of parameters (e–k) were >80%. Regarding dimensions, (l) the biliary lesions were longer in IgG4-SC than in EH-CCA. (m) The diameters of the dilated proximal common bile duct and (n) the dilated proximal intrahepatic bile duct were smaller in IgG4-SC than in EH-CCA. Conclusion: A number of CT findings are useful for differentiating between IgG4-SC and EH-CCA. CT findings (e–k) are particularly useful for this purpose. - Highlights: • Some CT findings are useful for differentiating between IgG4-SC and EH-CCA. • Homogeneous attenuation in all phases was more common in IgG4-SC than in EH-CCA. • Abnormal pancreatic findings showed high sensitivity and specificity values. • Dual-layered attenuation in all phases was more common in EH-CCA than in IgG4-SC.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  2. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  3. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  4. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  5. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  6. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  7. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  8. Myocardial perfusion 320-row multidetector computed tomography-guided treatment strategy for the clinical management of patients with recent acute-onset chest pain: Design of the CArdiac cT in the treatment of acute CHest pain (CATCH)-2 randomized controlled trial.

    Science.gov (United States)

    Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F

    2016-09-01

    Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  10. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  11. Comparison of calcium scoring with 4-multidetector computed tomography (4-MDCT) and 64-MDCT: a phantom study.

    Science.gov (United States)

    Serafin, Zbigniew; Rusak, Grazyna; Strześniewski, Piotr; Laskowska, Katarzyna; Lasek, Władysław

    2012-01-01

    To determine differences in coronary artery calcium (CAC) measurement performed with the use of 2 generations of multidetector computed tomography (CT) scanners of the same manufacturer. Agatston Score (AS) and calcium mass (CM) were measured with a 4-row scanner (AS4 and CM4) and a 64-row scanner (AS64 and CM64) using a cardiac phantom with calcium inserts. The results of the AS measurements (mean ± SD) varied significantly between the equipment: 880.6 ± 30.1 (AS4) vs 586.5 ± 24.0 (AS64; P < 0.0001). The AS interscanner variability was 31.6% for the phantom and from 25.5% to 110.1% for particular inserts. Mean ± SD CM values were different as well: 192.8 ± 5.0 mg (CM4) vs 152.4 ± 2.6 mg (CM64; P < 0.0001). Determination of CM with 64-row CT was more accurate than that with an older scanner; the mean relative error was -9.1% and 15.0%, respectively (P < 0.0001). The CM interscanner variability was 23.3% for the phantom and from 19.0% to 122.8% for particular inserts. The interexamination variability ranged from 1.7% (CM64) to 5.6% (AS4). Coronary artery calcium scoring with the 64-row CT scanner is more accurate than with the 4-row device The difference between the results of AS and CM measurements carried out with both scanners is statistically significant.

  12. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    International Nuclear Information System (INIS)

    Serafin, Z.; Lasek, W.; Laskowska, K.

    2008-01-01

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0±13.8 mg and 163.0±4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72±1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  13. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Lasek, W.; Laskowska, K. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2008-11-15

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0+-13.8 mg and 163.0+-4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72+-1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  14. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  15. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  16. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  17. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  18. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  19. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  20. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  1. Non-obstructive coronary artery disease assessed by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nielsen, L.; Bøtker, H. E.; Sorensen, H.

    2015-01-01

    Introduction: Coronary CT angiography (CTA) detects non-obstructive coronary artery disease (CAD) that may not be recognized by functional testing, but the prognostic impact is not well understood. This study aimed to compare the risk of myocardial infarction (MI) and all-cause mortality...... in patients without or with non-obstructive and obstructive CAD assessed by coronary CTA. Methods: Consecutive patients without known coronary artery disease (CAD) and with chest pain who underwent coronary CTA (>64-detector row) between January 2007 and December 2012 in the 10 centers participating...... in the Western Denmark Cardiac Computed Tomography Registry were included. The endpoints were 3-year MI or all-cause mortality. The coronary CTA result was defined as normal (0% luminal stenosis), non-obstructive CAD (1%-49% luminal stenosis) or obstructive CAD (>50% luminal stenosis; 1-vessel, 2-vessel, or 3...

  2. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  4. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  5. Efficacy of double arterial phase dynamic magnetic resonance imaging with the sensitivity encoding technique versus dynamic multidetector-row helical computed tomography for detecting hypervascular hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi; Uemura, Masahiko; Haraikawa, Toyoaki; Hirata, Masaaki; Kikuchi, Keiichi; Mochizuki, Teruhito; Kim, Tonsok

    2009-01-01

    The aim of this study was to evaluate the efficacy of double arterial phase dynamic magnetic resonance imaging (MRI) with the sensitivity encoding technique (SENSE dynamic MRI) for detection of hypervascular hepatocellular carcinoma (HCC) in comparison with double arterial phase dynamic multidetector-row helical computed tomography (dynamic MDCT). A total of 28 patients with 66 hypervascular HCCs underwent both double arterial SENSE dynamic MRI and dynamic MDCT. The diagnosis of HCC was based on surgical resection (n=7), biopsy (n=10), or a combination of CT during arterial portography (CTAP), CT during hepatic arteriography (CTA), and/or the 6-month follow-up CT (n=49). Based on alternative-free response receiving operating characteristic (ROC) analysis, the diagnostic performance for detecting HCC was compared between double arterial phase SENSE dynamic MRI and double arterial phase dynamic MDCT. The mean sensitivity, positive predictive value, and mean A Z values for hypervascular HCCs were 72%, 80%, and 0.79, respectively, for SENSE dynamic MRI and 66%, 92%, and 0.78, respectively, for dynamic MDCT. The mean sensitivity for double arterial phase SENSE dynamic MRI was higher than that for double arterial phase dynamic MDCT, but the difference was not statistically significant. Double arterial phase SENSE dynamic MRI is as valuable as double arterial phase dynamic MDCT for detecting hypervascular HCCs. (author)

  6. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  8. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  9. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  10. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  11. Estimation of aortic time-enhancement curve in pharmacokinetic analysis. Dynamic study by multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Kidoya, Eiji; Higashimura, Kyoji; Hayashi, Hiroyuki; Suzuki, Masayuki

    2007-01-01

    This paper presents an introduction to the development of software that provides a physiologic model of contrast medium enhancement by incorporating available physiologic data and contrast medium pharmacokinetics to predict an organ-specific aortic time-enhancement curve (TEC) in computed tomography (CT) with various contrast medium injection protocols in patients of various heights, weights, cardiac output levels, and so on. The physiologic model of contrast medium enhancement was composed of six compartments for early contrast enhancement pharmacokinetics. Contrast medium is injected via the antecubital vein and distributed to the right side of the heart, the pulmonary compartment, the left side of the heart, and the aorta. It then circulates back to the right side of the heart via the systemic circulation. A computer-based, compartmental model of the aortic system was generated using human physiologic parameters and six differential equations to describe the transport of contrast medium. Aortic TEC generated by the computer-based physiologic model of contrast medium enhancement showed validity and agreement with clinical data and findings published previously. A computer-based physiologic model that may help predict organ-specific CT contrast medium enhancement for different injection protocols was developed. Such a physiologic model may have multiple clinical applications. (author)

  12. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Joo, Ijin; Baek, Jee Hyun; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young; Park, Hee Sun

    2014-01-01

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  13. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Chen Tianwu; Yang Zhigang; Dong Zhihui; Li Yuan; Yao Jin; Wang Qiling; Qian Lingling

    2011-01-01

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 ± 0.49 whereas S/N ratios were 5.21 ± 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 ± 24.15 ml/min/ml, 24.06 ± 9.87 HU, 29.42 ± 8.61 s, and 12.45 ± 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  14. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  15. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, Konstantin; Becker, Christoph R.; Reiser, Maximilian F. [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Flohr, Thomas; Stierstorfer, Karl [CT Division, Siemens Medical Solutions, Forchheim (Germany)

    2005-02-01

    The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024 x 768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25 x 0.25 x 0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed. (orig.)

  16. Radiation Dose and Image Quality from Coronary Angiography in 320-Detecor Row CT

    International Nuclear Information System (INIS)

    Thanomphudsa, J.; Krisanachinda, A.; Tumkosit, M.

    2012-01-01

    Introduction: Coronary Computed Tomography Angiography examinations are increasing rapidly. New Computed Tomography has been developed to improve image quality with the patient dose reduction. The purpose of this study is to evaluate radiation dose and image quality of Coronary Computed Tomography Angiography in patients using 320-detector row CT. Methods: Forty-one patients referred for cardiac CT examinations at King Chulalongkorn Memorial Hospital were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on the 320-detector row CT, Toshiba Aquilion One. Scanning protocol was investigated on dose estimates and image quality. Patients were scanned base on heart rate (HR) by HR 75 bpm use retrospective with dose modulation. Scanning parameters, kVp, mAs, HR, BMI, CTDIvol(mGy) and DLP(mGy.cm), were recorded to study the factors affecting the image quality and patient dose. And mA and kVp setting depend on BMI of the patient. Effective dose is calculated from DLP using specific conversion factor. The image quality was evaluated in 4 vessels by two radiologists. Noise assessment was also studied quantitatively. Results: The patient effective dose in prospective gating 70-80% was 3.6 ± 0.9 mSv, prospective gating 30-80% (1R-R) was 6.3 ± 1.9 mSv, and 30-80% (2R-R) was 10.8 ± 1.8 mSv and in retrospective with tube current modulation was 12.1± 7.7 mSv. Image noise was highest in PGT 70-80% 1R-R and decreased in RGT with tube current modulation, PGT 30-80% 1R-R and lowest in PGT 30-80% 2 R-R. And overall qualitative image quality was mostly good to excellent score. Discussion: The heart rate, heart rate variability and disease of the patient are affecting in the radiation dose and image quality so the suitable acquisition protocol used could be necessary. the effective dose and the image noise for the image quality. (author)

  17. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  18. Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Jung, Yun Hoa [Pusan National Univ. College of Dentistry, Pusan (Korea, Republic of)

    2007-12-15

    To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserve agreements were calculated by using Kappa statistics. The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). This study shows that we can expert good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  19. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  20. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  1. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  2. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  3. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    International Nuclear Information System (INIS)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem; Wildi, Stefan; Bauerfeind, Peter

    2007-01-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  4. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  5. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  6. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  7. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  8. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  9. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  10. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  11. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  12. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  13. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    International Nuclear Information System (INIS)

    Fischer, Lars; Tetzlaff, Ralf; Schoebinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H.P.; Buechler, M.W.; Schemmer, Peter

    2010-01-01

    Introduction: The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. Material and Methods: All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Results: Segmentation of the liver was performed in significantly shorter time (p < 0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p = 0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p = 0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p = 0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these

  14. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  15. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  16. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  17. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  18. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  19. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  20. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  3. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  4. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  5. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  7. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A. [University Medical Center Utrecht and Wilhelmina Children' s Hospital, Department of Radiology, Utrecht (Netherlands)

    2012-02-15

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  8. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A.

    2012-01-01

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  9. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    Science.gov (United States)

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  10. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  11. Mechanical performance of aquatic rowing and flying.

    Science.gov (United States)

    Walker, J A; Westneat, M W

    2000-09-22

    Aquatic flight, performed by rowing or flapping fins, wings or limbs, is a primary locomotor mechanism for many animals. We used a computer simulation to compare the mechanical performance of rowing and flapping appendages across a range of speeds. Flapping appendages proved to be more mechanically efficient than rowing appendages at all swimming speeds, suggesting that animals that frequently engage in locomotor behaviours that require energy conservation should employ a flapping stroke. The lower efficiency of rowing appendages across all speeds begs the question of why rowing occurs at all. One answer lies in the ability of rowing fins to generate more thrust than flapping fins during the power stroke. Large forces are necessary for manoeuvring behaviours such as accelerations, turning and braking, which suggests that rowing should be found in slow-swimming animals that frequently manoeuvre. The predictions of the model are supported by observed patterns of behavioural variation among rowing and flapping vertebrates.

  12. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  13. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  14. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  15. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  16. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  17. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience; Angiotomografia computadorizada de coronarias com tomografo com 320 fileiras de detectores e utilizando o AIDR-3D: experiencia inicial

    Energy Technology Data Exchange (ETDEWEB)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao, E-mail: roberto.neto@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Failla, Bruna Bonaventura [Universidade Metodista de Sao Paulo, Sao Bernardo do Campo, SP (Brazil)

    2013-07-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  18. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  19. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  2. A concept of row crater enhancement

    International Nuclear Information System (INIS)

    Redpath, B.B.

    1970-01-01

    Linear craters formed by the simultaneous detonation of a row of buried explosives will probably have a wider application than single charges in the explosive excavation of engineering structures. Most cratering experience to date has been with single charges, and an analytical procedure for the design of a row of charges to excavate a crater with a specified configuration has been lacking. There are no digital computer codes having direct application to a row of charges as there are for single charges. This paper derives a simple relationship which can be used to design row charges with some assurance of achieving the desired result and with considerable flexibility in the choice of explosive yield of the individual charges

  3. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  4. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  5. Radiation doses to patients receiving computed tomography examinations in British Columbia

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Bilawich, A.-M.; Mayo, J.R.

    2006-01-01

    To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen/pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen/pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany. (author)

  6. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  7. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  8. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  15. The computation of ionization potentials for second-row elements by ab initio and density functional theory methods

    International Nuclear Information System (INIS)

    Jursic, B.S.

    1996-01-01

    Up to four ionization potentials of elements from the second-row of the periodic table were computed using the ab initio (HF, MP2, MP3, MP4, QCISD, GI, G2, and G2MP2) and DFT (B3LY, B3P86, B3PW91, XALPHA, HFS, HFB, BLYP, BP86, BPW91, BVWN, XAPLY, XAP86, XAPW91, XAVWN, SLYR SP86, SPW91 and SVWN) methods. In all of the calculations, the large 6-311++G(3df,3pd) gaussian type of basis set was used. The computed values were compared with the experimental results and suitability of the ab initio and DFF methods were discussed, in regard to reproducing the experimental data. From the computed ionization potentials of the second-row elements, it can be concluded that the HF ab initio computation is not capable of reproducing the experimental results. The computed ionization potentials are too low. However, by using the ab initio methods that include electron correlation, the computed IPs are becoming much closer to the experimental values. In all cases, with the exception of the first ionization potential for oxygen, the G2 computation result produces ionization potentials that are indistinguishable from the experimental results

  16. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  17. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  18. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  20. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  1. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  3. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  4. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  5. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  6. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  7. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  10. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  11. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  12. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  13. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  14. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  15. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  16. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  17. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  18. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  19. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  20. Sacrococcygeal chordoma: increased 99mTc methylene diphosphonate uptake on single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppuswamy; Bhattacharya, Anish; Harisankar, Chidambaram Natarajan Balasubramaniam; Mittal, Bhagwant Rai; Goni, Vijay

    2012-01-01

    Chordoma is a malignant tumor arising from the remnants of the notochord, and is the most frequent primitive tumor of the sacrum. While most sacral tumors show increased concentration of bone-seeking radiopharmaceuticals, chordomas usually exhibit decreased uptake. The authors present an image of a sacrococcygeal chordoma with osteolysis and increased uptake of 99m Tc methylene diphosphonate on planar and single photon emission computed tomography/computed tomography bone scintigraphy. (author)

  1. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  2. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  3. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.; Azad, Mohammad; Moshkov, Mikhail

    2017-01-01

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  4. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.

    2017-06-21

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  5. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  6. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  7. Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Watadani, Takeyuki; Akahane, Masaaki; Ohtomo, Kuni; Yoshikawa, Takeharu

    2008-01-01

    Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One patient diagnosed as type IIIa with MDCT was pathologically diagnosed as type IV. Accuracy of MDCT in tumoral spread was 92.3%, although that of lymph node metastasis was 54%. MDCT is likely to play an important role in evaluation of focal lesion spread especially in intrapancreatic tumor invasion, although a greater number of cohort cases are necessary to clearly define its role. (author)

  8. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  9. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru

    1982-01-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  10. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de

  11. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  12. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    Kovac, M.; Nowak, M.; Kaufels, N.; Tambur, Z.

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  13. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  14. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  15. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  16. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  17. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  18. Clinical utility of dental cone-beam computed tomography: current perspectives

    OpenAIRE

    Jaju, Prashant P; Jaju, Sushma P

    2014-01-01

    Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology an...

  19. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  20. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  1. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Bas, Ahmet; Simsek, Osman; Kandemirli, Sedat Giray; Rafiee, Babak; Gulsen, Fatih; Numan, Furuzan

    2015-01-01

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  2. Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography

    International Nuclear Information System (INIS)

    Elke, Gunnar; Weiler, Norbert; Frerichs, Inéz; Fuld, Matthew K; Halaweish, Ahmed F; Hoffman, Eric A; Grychtol, Bartłomiej

    2013-01-01

    Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (r s = 0.89 right, r s = 0.90 left lung) and after local injury (r s = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%±1.1% by EIT and 5.4%±1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level. (paper)

  3. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  4. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  5. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  6. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  7. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  8. Computed tomography in epidural abscess, subdural empyema, meningitis, and brain abscess

    International Nuclear Information System (INIS)

    Schadel, A.; Boettcher, H.D.; Haverkamp, U.; Wagner, W.; Schmilowski, G.M.; Muenster Univ.

    1983-01-01

    Computerised tomography cannot be of great help in diagnosing meningitis. Examination of the cerebrospinal fluid remains essential. After the inflammation of the meninges has progressed to some stage of encephalitis, the formation of an abscess can be located via computed tomography. It is characterised by the ring-type abscess capsule. Computed tomography for diagnostic purposes is superior to cerebral scanning, which demonstrates enhanced activity, but does not show the formation of a membrane, so essential for differential diagnosis. Furthermore, computed tomography shows the adjacent anatomical structures and answers the questions of displacements and threatening invasion of the ventricle system. Epidural and subdural abscesses can also be located by computed tomography. Therapy can begin directly after computerised tomography, whereas in scintigraphy only a non-specific enhanced activity is present, which often does not allow differentiation between epidural and subdural location. (orig.) [de

  9. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  10. Computed tomography of craniomandibular osteopathy in a dog

    International Nuclear Information System (INIS)

    Hudson, J.A.; Montgomery, R.D.; Hathcock, J.T.; Jarboe, J.M.

    1994-01-01

    This report describes the use of computed tomography (CT) to evaluate the tympanic bullae and angular processes of the mandible in a West Highland White Terrier with craniomandibular osteopathy. The patient presented initially for swelling of the right forelimb. The report illustrates the use of computed tomography for evaluation of craniomandibular osteopathy, initial presentation with long-bone pathology, and remarkable resolution of osseous changes

  11. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  12. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  14. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  15. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  16. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  17. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  19. Computed tomography of the head in neurological examination of children

    International Nuclear Information System (INIS)

    Baeckman, E.; Egg-Olofsson, O.; Raadberg, C.

    1980-01-01

    A total of 247 children from the departments of pediatrics and neurosurgery were examined with computed tomography of the head during a two year period in 1977-78. Pathological changes were demonstrated in 79 per cent. Supplementary neuro-radiological examination - angiography and encephalography - was necessary in 17 per cent. Computed tomography together with the clinical assessment frequently suffices for final diagnosis. Computed tomography greatly reduces the need for previously used neurological examinations including skull radiography. Complications may ensure because of over-sensitivity to intravenously administered contrast medium in connection with anesthesia, and the radiation dose particularly to the crystalline lens of the eye must be taken into account. Computed tomography should therefore be used only on strict indications after careful scrutiny of the case history and the status. (author)

  20. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  1. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  2. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  3. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  4. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  5. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  6. Effects of computer tomography on diagnosis of neurological and neurosurgical diseases

    International Nuclear Information System (INIS)

    Katzner, E.

    1981-01-01

    Computer tomography is presently the primary procedure for correct diagnosis of many neurological and neurosurgical diseases. Other expensive and riskier diagnostic methods have become superfluous. Selective and clearly indicated application of the undoubtedly expensive computer tomography ultimately spares unnecessary costs for hospitalization and less conclusive examination methods. Wheras the indications in the craniocerebral region can now be considered confirmed, spinal computer tomography is still in the development stage. With certain indications, e.g. in prolapsed lumbar intervertebral disk, a similar performance to that of CT can be obtained with myelography, so that the latter method is likely to be superceded by computer tomography. (orig.) [de

  7. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  8. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  9. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  10. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  11. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    International Nuclear Information System (INIS)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Al brecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2008-01-01

    Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberte and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70-80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberte stent (11.3±10.2 HU) and the Multi-Link Vision stent (17.6±17.9 HU; P 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberte stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and

  12. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  13. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  14. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  15. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  16. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

    Science.gov (United States)

    Sandgren, Buster; Crafoord, Joakim; Garellick, Göran; Carlsson, Lars; Weidenhielm, Lars; Olivecrona, Henrik

    2013-10-01

    Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  18. Radiation dose in cone-beam computed tomography: myth or reality

    International Nuclear Information System (INIS)

    Madi, Medhini

    2013-01-01

    In the growing inventory of clinical computed tomography technologies, cone-beam X-ray computed tomography is a relatively recent instalment. It is an advancement in computed tomography imaging which is designed to provide relatively low-dose high-spatial-resolution visualization of high contrast structures in the head and neck and other anatomic areas. Comparatively low dosing requirements and relatively compact design has led to intense interest in surgical planning and intra-operative cone-beam computed tomography applications, particularly in head and neck, and also in spinal, thoracic, abdominal and orthopaedic procedures. The use of this emerging imaging technology, which has potential applications for imaging of high-contrast structures in the head and neck as well as dentomaxillofacial regions, has been the subject of criticism as well as acclaim. This paper envisages to discuss the state-of-the-art of the technique. (author)

  19. Computer tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Petkov, D.; Zhelyazkov, S.; Nedelkov, G.

    1983-01-01

    The modern achievements in the clinical study and diagnosis of liver diseases has definitely been associated with the application of whole body computer tomography (CT) in the practice. The diagnostic possibilities of the method come from high contrast and spacial disjunctive capabilities. Visualization of local lesions is associated with their size and the differences in their densitometric compactness from that of the normal parenchyma. The advantages of computer tomography in the diagnosis of liver diseases is discussed. They are associated with the possibilities for densitometric analysis of the pathologic changes, which opens a way for a probable qualitative diagnosis. Diffuse processes in the liver are relative indication for performing computer tomography. Examination under conditions of contrast amplification is indicated in cases when the nature of the lesion has to be specified and a ''negative'' result does not concur with the clinical manifestations. (authors)

  20. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  1. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  2. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  3. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  4. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  5. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  6. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  7. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  8. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  9. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  10. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  11. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  12. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  13. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  14. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  15. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  16. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  17. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  18. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  19. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  20. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  1. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  2. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  3. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  4. Limitations of airway dimension measurement on images obtained using multi-detector row computed tomography.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Oguma

    Full Text Available OBJECTIVES: (a To assess the effects of computed tomography (CT scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai, and the wall area percentage (WA%. To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. RESULTS: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001, and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. CONCLUSIONS: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner.

  5. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  6. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  7. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  8. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  10. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  13. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Vallejos, J.; Capunay, Carlos M.; Deviggiano, A.; Carrascosa, Jorge M.

    2007-01-01

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine [es

  14. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  15. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  16. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  17. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  18. Multiple detector-row CT angiography of the renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik. E-mail: dominik.fleischmann@univie.ac.at

    2003-03-01

    Computed tomography angiography (CTA) of the abdomen with multiple detector-row computed tomography (MD-CT) is an effective technique for minimally invasive imaging of the renal arteries and the visceral vasculature. This article reviews the clinical and technical aspects of MD-CT angiography in terms of image acquisition and reconstruction parameters, contrast medium application, and three-dimensional visualization with special attention to renal and mesenteric vascular imaging. Because of its high sensitivity to detect renal artery stenosis on the one hand, and because a normal renal CTA virtually excludes the presence of a significant renal artery stenosis on the other hand, renal CTA plays a useful role in the management of patients with suspected renovascular hypertension. Mesenteric CTA is a useful tool for visualizing normal vascular anatomy and its variants--particularly in the setting of organ transplantation. Vascular pathology, e.g. atherosclerotic disease (abdominal angina), or aneurysms of the visceral arteries are reliably assessed with CTA. Mesenteric CTA is an invaluable adjunct to abdominal CT in the setting of abdominal emergencies, because of its ability to detect the causes of acute intestinal ischemia (superior mesenteric artery embolism or thrombosis, superior mesenteric vein thrombosis). Accurate timing of the CTA acquisition and the subsequent parenchymal phase acquisition relative to the contrast medium transit time is critical to obtain excellent image quality in double-pass abdominal CT acquisitions.

  19. Computed tomography of the mediastinum in myasthenia gravis

    International Nuclear Information System (INIS)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.; Hamburg Univ.; Hamburg Univ.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours. (orig.) [de

  20. Computed tomography in the evaluation of acquired stenosis in the neonate

    International Nuclear Information System (INIS)

    Faw, K.; Muntz, H.; Siegel, M.; Spector, G.

    1982-01-01

    We studied the feasibility of computed tomographic evaluation of the neonatal airway. Three neonatal larynges, removed at necroscopy, were examined by computed tomography. Good resolution of soft tissue, cartilage and airway lumen was obtained in these small specimens. On the basis of these findings two neonates with acquired subglottic stenosis were examined by endoscopy, soft tissue airway radiographs, and computed tomography. Measurements of radiation dose revealed that a computed tomographic study delivered 36% of the mean tissue dose of standard image intensifier fluoroscopy. Computed tomography and fluoroscopy both demonstrated the degree and length of this stenosis accurately. An advantage of CT over conventional imaging procedures was better definition of the cross sectional area of the airway

  1. Resonant Quasi-Optical Systems with Multi-Row Periodic Structures

    DEFF Research Database (Denmark)

    Oleksandr, Rybalko; Rybalko, Yu A.; Buriak, I. A.

    2017-01-01

    Selective properties of resonant quasi-optical systems with periodical multi-row structures in millimeter wavelength range are described. The possibility of selection fluctuations in the volume of open resonator using double-row periodic elements was shown in the experiment at 70-80 GHz. Advantages...... and possibility of control the energy characteristics of such structures are also described. The obtained experimental data is used to confirm the results of computational analysis previously described in the literature. Implementation of resonant quasi-optical systems with multi-row periodic structures...

  2. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  3. Computed tomography of human joints and radioactive waste drums

    International Nuclear Information System (INIS)

    Martz, Harry E.; Roberson, G. Patrick; Hollerbach, Karin; Logan, Clinton M.; Ashby, Elaine; Bernardi, Richard

    1999-01-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have seen increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed, 1.) Our computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. 2.) We are developing NDE and NDA techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity

  4. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  5. Initial water quantification results using neutron computed tomography

    Science.gov (United States)

    Heller, A. K.; Shi, L.; Brenizer, J. S.; Mench, M. M.

    2009-06-01

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at the Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  6. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Science.gov (United States)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  7. Multislice helical computed tomography in the evaluation of lumbar spine diseases

    International Nuclear Information System (INIS)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao

    2003-01-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  8. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  9. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    Science.gov (United States)

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  11. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  12. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  13. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  14. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients.

  15. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    International Nuclear Information System (INIS)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients

  16. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  17. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  18. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  19. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  20. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  1. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  2. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  3. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  4. Computed tomography of thymic abnormalities: review of 10 patients

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Brito Pacheco, E.M. de; Cazerta, N.M.G.; Silva, M.J.G. da

    1990-01-01

    Chest radiographs and computed tomographic scans of the mediastinum were correlated with pathologic findings of the thymus following thymectomy in 10 patients with thymic disease. There were five patients with thymoma, four with thymic hiperplasia and one with benign thymic cyst. Computed tomography shoud be the imaging method of choice following plain chest radiographs when a suspect thymic abnormality requires further evaluation. Recognition of variations in the normal location, size, shape and density of the thymus prevents misinterpretation as abnormal mediastinal mass. Furthermore, knowledge of the normal computed tomography appearance has proved helpful in evaluating thymic abnormalities. (author)

  5. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    Science.gov (United States)

    2017-07-13

    Computed Tomography Scans by Autumn R Kulaga, Kathryn L Loftis, and Eric Murray Approved for public release; distribution is...Army Research Laboratory Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans by Autumn R Kulaga...Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  6. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  7. X-ray Computed Tomography of Ultralightweight Metals

    National Research Council Canada - National Science Library

    Winter, John

    2001-01-01

    .... To date, the imaging capabilities of x-ray computed tomography have not been generally employed to nondestructively examine the internal structure of the products formed by these various processes...

  8. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  9. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  10. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  11. A comparative study of electrocardiogram multi-segment reconstruction and dual source computed tomography using a computer controlled coronary phantom

    International Nuclear Information System (INIS)

    Ohashi, Kazuya; Higashide, Ryo; Kunitomo, Hirosi; Ichikawa, Katsuhiro

    2011-01-01

    Currently, there are two main methods for improving temporal resolution of coronary computed tomography (CT): electrocardiogram-gated multi-segment reconstruction (EMR) and dual source scanning using dual source CT (DSCT). We developed a motion phantom system for image quality assessment of cardiac CT to evaluate these two methods. This phantom system was designed to move an object at arbitrary speeds during a desired phase range in cyclic motion. By using this system, we obtained coronary CT mode images for motion objects like coronary arteries. We investigated the difference in motion artifacts between EMR and the DSCT using a 3-mm-diameter acrylic rod resembling the coronary artery. EMR was evaluated using 16-row multi-slice CT (16MSCT). To evaluate the image quality, we examined the degree of motion artifacts by analyzing the profiles around the rod and the displacement of a peak pixel in the rod image. In the 16MSCT, remarkable increases of artifacts and displacement were caused by the EMR. In contrast, the DSCT presented excellent images with fewer artifacts. The results showed the validity of DSCT to improve true temporal resolution. (author)

  12. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  13. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  14. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  15. Non-invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects.

    Science.gov (United States)

    Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto

    2004-02-01

    The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.

  16. Computed tomography in space-occupying intraspinal processes

    International Nuclear Information System (INIS)

    Proemper, C.; Friedmann, G.

    1983-01-01

    Spinal computed tomography has considerably enhanced differential diagnostic safety in the course of the past two years. It has disclosed new possibilities of indication in the diagnosis of the vertebral column. With the expected improvement in apparatus technology, computed tomography will increasingly replace invasive examination methods. Detailed knowledge of clinical data, classification of the neurological findings, and localisation of the height - as far as possible - are the necessary prerequisites of successful diagnosis. If they are absent, it is recommended to perform myelography followed by secondary CT-myelography. If these preliminary conditions are observed, spinal CT can make outstanding contributions to be diagnosis of slipped disk, of the constricted vertebral canal, as well as tumours, malformations and posttraumatic conditions, postoperative changes and inflammatory processes. (orig.) [de

  17. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  18. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  19. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  20. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  1. Computed tomography in orbital fractures and optic nerve trauma

    International Nuclear Information System (INIS)

    Dietrich, U.; Sievers, K.; Feldges, A.; Nau, H.E.

    1990-01-01

    Ten patients with orbital fractures and optic nerve trauma are reported. Fractures of the optic canal could be demonstrated by computed tomography in six cases and fractures of the orbital apex in another three cases. Surgical decompression of the optic canal was performed in seven cases. Computed tomography enhanced decision for surgery in cases of intraorbital haematoma with exophthalmus and narrowing of the canal by bony fragments, especially in those patients presenting with incomplete or progressive visual disturbance. (orig.) [de

  2. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  3. Pediatrics patient in computed tomography: risk awareness among medical staff

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Kosutic, D.; Lazarevic, Dj.

    2009-01-01

    In this paper the results of investigation about risk awareness in pediatrics computed tomography among medical staff are presented. Questionnaires were distributed along seven hospitals, 84 people were enrolled in this investigation. The results showed awareness of the potential risks associated with ionizing radiation in computed tomography. However, there is still widespread underestimation of relative doses and risks in case of pediatric patients. (author) [sr

  4. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  5. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  6. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  7. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  8. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  9. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  10. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  11. [Cardiac computed tomography: new applications of an evolving technique].

    Science.gov (United States)

    Martín, María; Corros, Cecilia; Calvo, Juan; Mesa, Alicia; García-Campos, Ana; Rodríguez, María Luisa; Barreiro, Manuel; Rozado, José; Colunga, Santiago; de la Hera, Jesús M; Morís, César; Luyando, Luis H

    2015-01-01

    During the last years we have witnessed an increasing development of imaging techniques applied in Cardiology. Among them, cardiac computed tomography is an emerging and evolving technique. With the current possibility of very low radiation studies, the applications have expanded and go further coronariography In the present article we review the technical developments of cardiac computed tomography and its new applications. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  12. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  13. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  14. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  15. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  16. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  17. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  18. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears.

    Science.gov (United States)

    Mihata, Teruhisa; Watanabe, Chisato; Fukunishi, Kunimoto; Ohue, Mutsumi; Tsujimura, Tomoyuki; Fujiwara, Kenta; Kinoshita, Mitsuo

    2011-10-01

    Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Cohort study; Level of evidence, 3. There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya's classification of magnetic resonance imaging (MRI). The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P row group (5 of 12 shoulders, 41.7%, P row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.

  19. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  20. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    International Nuclear Information System (INIS)

    Ferda, Jiri; Hora, Milan; Hes, Ondrej; Reischig, Tomas; Kreuzberg, Boris; Mirka, Hynek; Ferdova, Eva; Ohlidalova, Kristyna; Baxa, Jan; Urge, Tomas

    2007-01-01

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC's. Bilateral renal tumors were found in our study

  1. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...

  2. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  3. Cone beam computed tomography: basics and applications in dentistry.

    Science.gov (United States)

    Venkatesh, Elluru; Elluru, Snehal Venkatesh

    2017-01-01

    The introduction of cone beam computed tomography (CBCT) devices, changed the way oral and maxillofacial radiology is practiced. CBCT was embraced into the dental settings very rapidly due to its compact size, low cost, low ionizing radiation exposure when compared to medical computed tomography. Alike medical CT, 3 dimensional evaluation of the maxillofacial region with minimal distortion is offered by the CBCT. This article provides an overview of basics of CBCT technology and reviews the specific application of CBCT technology to oral and maxillofacial region with few illustrations.

  4. Computed tomography and plain radiography in experimental fracture healing

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Goldstein, S.A.; Ku, J.; Smith, P.; Matthews, L.S.

    1986-01-01

    We evaluated the relative contribution of plain radiographs and computed tomography to the assessment of fracture healing under experimental circumstances. In 15 sheep, we performed midshaft femoral osteotomies and internal fixation of the resultant segmental fractures. Radiographs were obtained preoperatively and immediately postoperatively. Animals were sacrificed at 3 weeks, 6 weeks, 12 weeks, 24 weeks, and 36 weeks after surgery, and the femoral specimens radiographed. After removal of the internal fixation devices, computed tomographic scans of the specimens were performed. Computed tomography may be of value in the evaluation of fractures of long bones in those cases in which clinical examination and plain radiographs fail to give adequate information as to the status of healing. (orig./SHA)

  5. Development of industrial x-ray computed tomography and its application to refractories

    International Nuclear Information System (INIS)

    Aiba, Yoshiro; Oki, Kazuo; Nakamura, Shigeo; Fujii, Masashi.

    1985-01-01

    An industrial X-ray computed tomography was developed under the influence of the rapid spread of the use of the X-ray CT scanner in the medical field and improvements of the equipment. Although current nondestructive testing machines of refractories use the ultrasonic inspection method or the X-ray fluoroscopic method, these equipments cannot produce a tomogram or cannot carry out quantitative evaluation. By using an industrial X-ray computed tomography, submerged nozzles for continuous casting of steel were analyzed with interesting results. The features of the industrial X-ray computed tomography applied for refractory nozzles are as follows: (1) It promptly detects interior defects. (2) It can measure dimensions and shapes. (3) It can numerically express the distribution of density. Accordingly, it is expected that the industrial X-ray computed tomography will widely be used in the fields of development and quality control of refractories and advanced ceramic materials. (author)

  6. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  7. Incidence of retear with double-row versus single-row rotator cuff repair.

    Science.gov (United States)

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  8. Pulmonary artery aneurysm in Bechcet's disease: helical computed tomography study

    International Nuclear Information System (INIS)

    Munoz, J.; Caballero, P.; Olivera, M. J.; Cajal, M. L.; Caniego, J. L.

    2000-01-01

    Behcet's disease is a vasculitis of unknown etiology that affects arteries and veins of different sizes and can be associated with pulmonary artery aneurysms. We report the case of a patient with Behcet's disease and a pulmonary artery aneurysm who was studied by means of plain chest X ray, helical computed tomography and pulmonary arteriography. Helical computed tomography is a reliable technique for the diagnosis and follow-up of these patients. (Author) 9 refs

  9. Advances in equine computed tomography and use of contrast media.

    Science.gov (United States)

    Puchalski, Sarah M

    2012-12-01

    Advances in equine computed tomography have been made as a result of improvements in software and hardware and an increasing body of knowledge. Contrast media can be administered intravascularly or intrathecally. Contrast media is useful to differentiate between tissues of similar density. Equine computed tomography can be used for many different clinical conditions, including lameness diagnosis, fracture identification and characterization, preoperative planning, and characterization of skull diseases. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  11. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  12. Image reconstruction from projections and its application in emission computer tomography

    International Nuclear Information System (INIS)

    Kuba, Attila; Csernay, Laszlo

    1989-01-01

    Computer tomography is an imaging technique for producing cross sectional images by reconstruction from projections. Its two main branches are called transmission and emission computer tomography, TCT and ECT, resp. After an overview of the theory and practice of TCT and ECT, the first Hungarian ECT type MB 9300 SPECT consisting of a gamma camera and Ketronic Medax N computer is described, and its applications to radiological patient observations are discussed briefly. (R.P.) 28 refs.; 4 figs

  13. Metaanalysis of Diagnostic Performance of Computed Coronary Tomography Angiography, Computed Tomography Perfusion and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment versus Invasive Fractional Flow Reserve

    Science.gov (United States)

    Gonzalez, Jorge A.; Lipinski, Michael J.; Flors, Lucia F.; Shaw, Peter; Kramer, Christopher M.; Salerno, Michael

    2015-01-01

    We sought to compare the diagnostic performance of computed coronary tomography angiography (CCTA), computed tomography perfusion (CTP) and computed tomography fractional flow reserve (CT-FFR) for assessing the functional significance of coronary stenosis as defined by invasive fractional flow reserve (FFR), in patients with known or suspected coronary artery disease. CCTA has proven clinically useful for excluding obstructive CAD due to its high sensitivity and negative predictive value (NPV), however the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP or CT-FFR for the non-invasive detection of obstructive CAD as compared to catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios (LR), odds ratio (OR) of all diagnostic tests were assessed. Eighteen studies involving a total of 1535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56 and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77 respectively (P=0.004 and P=0.0009)) resulting in higher point estimates for PPV 0.70 and 0.83 respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA VS 9.6 mSv CTP) and a higher volume of iodinated contrast (145 mL). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to non-invasively detect the functional significance of coronary lesions. PMID:26347004

  14. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  15. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence.

    Science.gov (United States)

    Wall, Lindley B; Keener, Jay D; Brophy, Robert H

    2009-01-01

    A review of the current literature will show a difference between the biomechanical properties of double-row and single-row rotator cuff repairs. Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. We reviewed the literature of all biomechanical studies comparing double-row vs single-row repair techniques. Inclusion criteria included studies using cadaveric, animal, or human models that directly compared double-row vs single-row repair techniques, written in the English language, and published in peer reviewed journals. Identified articles were reviewed to provide a comprehensive conclusion of the biomechanical strength and integrity of the repair techniques. Fifteen studies were identified and reviewed. Nine studies showed a statistically significant advantage to a double-row repair with regards to biomechanical strength, failure, and gap formation. Three studies produced results that did not show any statistical advantage. Five studies that directly compared footprint reconstruction all demonstrated that the double-row repair was superior to a single-row repair in restoring anatomy. The current literature reveals that the biomechanical properties of a double-row rotator cuff repair are superior to a single-row repair. Basic Science Study, SRH = Single vs. Double Row RCR.

  16. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  17. Multidetector row computed tomography findings from ischemia to infarction of the large bowel

    International Nuclear Information System (INIS)

    Romano, Stefania; Romano, Luigia; Grassi, Roberto

    2007-01-01

    Objective: MDCT is performed as first imaging examination for patients with acute abdomen in most Emergency Departments. Clinical suspicion of ischemic colitis and infarction is related to specific findings, however, differential diagnosis as well as the staging for a confirmed ischemic affection may be critical. The individual signs from ischemia to infarction of large bowel is a captivating topic. In this study, we report our experience of the MDCT assessment of acute colonic disease from vascular mesenteric disorders. Materials and methods: We retrospectively reviewed the MDCT findings of 71 patients admitted to our attention for acute abdomen, with final proven diagnosis of colonic ischemia and/or infarction made by surgery and/or endoscopy. CT-scanning of the abdomen and pelvis was performed after i.v. contrast medium administration, using a multidetector row CT equipment. We correlated the presence of parietal disease, the evidence of mesenteric arterial or venous vessels occlusion, the parietal features as well as others findings, such as free fluid and/or air in peritoneal recess or in retroperitoneum, with the surgical and/or endoscopic findings. Results: Analysis of our data showed a segmental (84%) or complete (16%) involvement of the colon; 57 cases were related to ischemia, 14 to infarction. Inferior mesenteric vessels defect of opacification was noted in 10 cases. Various degree of wall thickening and parietal enhancement, peritoneal fluid, mural or portal-mesenteric pneumatosis were compared to evidence of mesenteric arterial or vein occlusion and to final proven diagnosis. A classification in a multi-stage grading for both decreased of arterial supply or impaired venous drainage disorders was done. Conclusions: A grading scale from ischemia to infarction affecting the large bowel from arterial or venous mesenteric vessels origin has been not previously reported in a series at our knowledge. MDCT findings may support the clinical evaluation of

  18. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  19. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  20. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  1. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    Directory of Open Access Journals (Sweden)

    Talita Zerbini

    2014-12-01

    Full Text Available Objective: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. Method: Comparison between the findings of different methods: autopsy and postmortem computed tomography. Results: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. Conclusions: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations.

  2. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  3. Reconstructed frontal and coronal cuts in computed tomography of the trunk

    International Nuclear Information System (INIS)

    Fochem, K.; Klumair, J.

    1982-01-01

    A comparison between the original coronally cuts and the reconstructed coronal cuts yielded basic information on the loss of quality by computed reconstruction of images. As for the trunk, only comparisons between the conventional linear tomography and computed frontal of trunk cuts are possible. A few examples will demonstrate that despite a considerable loss of quality, computed frontal cuts will supply additional information in certain cases. It is also shown that the reconstructed frontal cuts cannot replace conventional tomography. (orig.) [de

  4. Value of radio density determined by enhanced computed tomography for the differential diagnosis of lung masses

    International Nuclear Information System (INIS)

    Xie, Min

    2011-01-01

    Lung masses are often difficult to differentiate when their clinical symptoms and shapes or densities on computed tomography images are similar. However, with different pathological contents, they may appear differently on plain and enhanced computed tomography. Objectives: To determine the value of enhanced computed tomography for the differential diagnosis of lung masses based on the differences in radio density with and without enhancement. Patients and Methods: Thirty-six patients with lung cancer, 36 with pulmonary tuberculosis and 10 with inflammatory lung pseudo tumors diagnosed by computed tomography and confirmed by pathology in our hospital were selected. The mean ±SD radio densities of lung masses in the three groups of patients were calculated based on the results of plain and enhanced computed tomography. Results: There were no significant differences in the radio densities of the masses detected by plain computed tomography among patients with inflammatory lung pseudo tumors, tuberculosis and lung cancer (P> 0.05). However, there were significant differences (P< 0.01)between all the groups in terms of radio densities of masses detected by enhanced computed tomography. Conclusions: The radio densities of lung masses detected by enhanced computed tomography could potentially be used to differentiate between lung cancer, pulmonary tuberculosis and inflammatory lung pseudo tumors.

  5. Automated aortic calcium scoring on low-dose chest computed tomography

    International Nuclear Information System (INIS)

    Isgum, Ivana; Rutten, Annemarieke; Prokop, Mathias; Staring, Marius; Klein, Stefan; Pluim, Josien P. W.; Viergever, Max A.; Ginneken, Bram van

    2010-01-01

    Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm 3 out of 965 mm 3 (97.9%) calcified plaque volume in the aorta with an average of 64 mm 3 of false positive volume per scan. Spearman rank correlation coefficient was ρ=0.960 between the system and the

  6. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  7. Hematocrit and Serum Hemoglobin Do Not Influence Values in Computed Tomography Perfusion of Patients With Acute Ischemic Stroke.

    Science.gov (United States)

    Karwacki, Grzegorz Marek; Benz, Matthias Richard; Tyndall, Anthony Joseph; Ulmer, Stephan

    There is a correlation between both serum hemoglobin (HGB) and hematocrit (HCT) and attenuation values of vessels in noncontrast-enhanced computed tomography (NECT), which could influence calculated perfusion maps in CT perfusion. We retrospectively included 45 patients, who presented with acute new neurological symptoms and underwent NECT and CT perfusion (128-row multi detector scanner, coverage: 6.9 cm craniocaudally; 80 kV; 200 mAs; temporal resolution: 2 seconds using 40 mL Ultravist 370 at a flow rate of 5 mL/s) on admission and a follow-up MRI within 1 week of admission. Hematocrit, HGB, and attenuation values did not differ between patients with stroke and controls. A statistically significant correlation was found between HCT and HGB and attenuation values in the internal carotid artery or middle cerebral artery on NECT (P Hematocrit and HGB do not influence calculated perfusion maps. There is no need for HCT/HGB-adjusted cerebral blood volume thresholds in stroke patients.

  8. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  9. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    International Nuclear Information System (INIS)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D'Ippolito, Giuseppe

    2013-01-01

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  10. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    Science.gov (United States)

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  12. [Visualization of laryngopharynx during swallowing of negative contrast media (air) with cine mode 64-row MDCT].

    Science.gov (United States)

    Fudeya, Taku; Otake, Shoichiro; Watabe, Hirotaka; Mitsuoka, Takashi; Yoshikawa, Akitoshi

    2010-05-20

    Video fluoroscopic examination of swallowing generally needs a contrast media such as a barium sulfate. Since the examination is usually performed in patients with dysphasia, there is a risk of aspiration. We tried to visualize the laryngopharynx during swallowing of negative contrast media (air) with 64-row multi-detector computed tomography (64-MDCT). Cine mode 64-MDCT was performed to visualize the laryngopharynx in 4 healthy volunteers during swallowing of negative contrast media (air). The data were converted to three-dimensional (3D) images of 2 conditions (air and bone) and sagittal images of the soft tissue condition at a workstation. These images were sent to a personal computer and modeled to 3D cine images with Digital Imaging and Communication in Medicine (DICOM) Viewer and Quick Time Player. 3D cine images demonstrated movements of the epiglottis, vallecula, piriform sinus, tongue, pharyngeal wall, hyoid bone and thyroid cartilage.

  13. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  14. Our experience in the diagnosis of aortic dissection by multislice computed tomography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis R; Mendoza Rodriguez, Vladimir; Olivares Aquiles, Eddy

    2011-01-01

    Aortic dissection (AD) is the most frequent and life-threatening acute aortic syndrome. Currently the more used method for the aortic study is the multislice computed tomography. The purpose of this paper is to expose the more relevant features in 22 patients with AD consecutively studied by multislice computed tomography

  15. Evaluation of alternative methods for coronary calcium scoring in multi-detector-row computed tomography

    International Nuclear Information System (INIS)

    Serafin, Z.; Lasek, W.; Laskowska, K.; Marzec, M.

    2005-01-01

    Determining coronary artery calcifications is one of the methods of coronary heart disease screening. However, the traditional Agatston Calcium Score (CS) shows low interexamination reproducibility. The aim of this study was to evaluate the interscan variability coefficients of calcium measures based on three modifications of the original Agatston equation. Fifty adults (37 men and 13 women; mean age 46.2 ± 9.2 years) were included in the study. Each patient was examined with two consecutive, prospectively electrocardiographically triggered, multi-detector-row CT acquisitions to detect and quantify coronary artery calcifications. CS was calculated according to the method by Agatston et al. Alternative scores were calculated using a continuous weighting factor (CS-CM), the average lesion attenuation value (CS-SA), or both (CS-CA). The mean and median interscan percent variabilities of the methods were evaluated using nonparametric analysis of variance. In the 50 patients, 1315 calcified lesions were found. The alternative scores correlated well with CS (for CS vs. CS-SA, CS-CM, and CS-CA, r = 0.990, 0.840, and 0.946, respectively, P < 0.0001). The mean and median percent variabilities did not differ significantly among the methods tested (P = 0.370). For CS, CS-SA, CS-CM, and CS-CA the mean variabilities were 13.24%, 13.36%, 16.00%, and 13.62%, respectively. Except for CS-CM, the methods showed similar distributions of variability vs. score on Bland and Altman plots. None of the tested modifications of the Agatston method brought improvement in the interscan reproducibility of coronary calcium scoring. In our opinion, a significant reduction in variability may be achieved by a standardization of image acquisition and reconstruction. (author)

  16. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  17. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  18. Vascular air embolism after contrast administration on 64 row multiple detector computed tomography: A prospective analysis

    Directory of Open Access Journals (Sweden)

    Kushaljit S Sodhi

    2015-01-01

    Full Text Available Background: Vascular air embolism is being progressively reported as a nonfatal event with increase in use of computed tomography (CT as a diagnostic modality. This study was undertaken to study the frequency and site of vascular air embolism in patients undergoing contrast-enhanced CT (CECT and analyze CT parameters that influence its prevalence and final outcome. Materials and Methods: This was a prospective study approved by departmental ethics committee. Presence and location of air emboli in 200 patients who underwent CT scan of chest on a 64 detector scanner was recorded. We analyzed the role of various factors that could influence the prevalence of air embolism after injection of contrast in CECT scans. These factors included the amount of contrast injected, rate of flow of injection of contrast, site of injection of contrast, and size of intravenous access line. Results: Iatrogenic vascular air emboli were seen in 14 patients (7% of total. The locations of air emboli were main pulmonary artery in 12 (6% of total, left brachiocephalic vein in 3 (1.5% of total, right atrial appendage in 4 (2% of total, and superior vena cava (SVC in 1 (0.5% patient. There was no association between volume of contrast, flow rate, site and size of intravenous access, and presence of air emboli. Conclusion: Radiologists as well as referring physicians should be aware of vascular air embolism, which can occur after contrast injection in patients undergoing CT scan. Age, volume of contrast, flow rate of pressure injector, and site and size of venous cannula do not influence the likelihood or incidence of detection of venous air emboli on CT scans.

  19. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  20. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  1. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    Science.gov (United States)

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki; Tsukagoshi, Shinsuke; Saito, Yasuo; Kazama, Masahiro; Ashizawa, Kazuto; Awai, Kazuo; Honda, Osamu; Ishikawa, Hiroyuki; Koizumi, Naoya; Komoto, Daisuke; Moriya, Hiroshi; Oda, Seitaro; Oshiro, Yasuji; Yanagawa, Masahiro; Tomiyama, Noriyuki; Asamura, Hisao

    2015-01-01

    Purpose The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. PMID:26352144

  2. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner.

    Directory of Open Access Journals (Sweden)

    Ryutaro Kakinuma

    Full Text Available The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT scanners.This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner.The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU] was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001. The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001 for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures.Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.

  3. Mandibular condyle position in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Hyoung Joo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Kyung Hee Univ. School of Dentistry, Seoul (Korea, Republic of)

    2006-06-15

    To evaluate position of the mandibular condyle within articular fossa in an asymptomatic population radiographically by a cone beam computed tomography. Cone beam computed tomography of 60 temporomandibular joints was performed on 15 males and 15 females with no history of any temporomandibular disorders, or any other orthodontic or photoconductors treatments. Position of mandibular condyle within articular fossa at centric occlusion was evaluated. A statistical evaluation was done using a SPSS. In the sagittal views, mandibular condyle within articular fossa was laterally located at central section. Mandibular condyles in the right and left sides were showed asymmetric positional relationship at medial, central, and lateral sections. Mandibular condyle within articular fossa in an asymptomatic population was observed non-concentric position in the sagittal and coronal views.

  4. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  5. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  6. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  7. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  8. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    Science.gov (United States)

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was dysfunction as well as a useful technique for predicting the prognosis of this condition.

  9. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Maryam Farghadani

    2016-01-01

    Full Text Available Background: The celiac axis, superior mesenteric artery (SMA, and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9% of the 607 patients had classic arterial anatomy and 219 (36.1% patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA from SMA (9.6%, and the next common variation was the origin of the left hepatic artery (LHA from the left gastric artery (6.9%. Variations in the origin of the common hepatic artery (CHA were seen in 16 (2.6% patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8% patients and from the aorta in 8 (1.3% patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8% patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  10. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens; Universidade Federal do Espirito Santo

    2017-01-01

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  11. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Universidade Federal do Espirito Santo (HUCAM/UFES), Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio de Morais. Radiologia e Diagnostico por Imagem

    2017-03-15

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  12. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  13. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  14. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  15. Optical RAM row access using WDM-enabled all-passive row/column decoders

    Science.gov (United States)

    Papaioannou, Sotirios; Alexoudi, Theoni; Kanellos, George T.; Miliou, Amalia; Pleros, Nikos

    2014-03-01

    Towards achieving a functional RAM organization that reaps the advantages offered by optical technology, a complete set of optical peripheral modules, namely the Row (RD) and Column Decoder (CD) units, is required. In this perspective, we demonstrate an all-passive 2×4 optical RAM RD with row access operation and subsequent all-passive column decoding to control the access of WDM-formatted words in optical RAM rows. The 2×4 RD exploits a WDM-formatted 2-bit-long memory WordLine address along with its complementary value, all of them encoded on four different wavelengths and broadcasted to all RAM rows. The RD relies on an all-passive wavelength-selective filtering matrix (λ-matrix) that ensures a logical `0' output only at the selected RAM row. Subsequently, the RD output of each row drives the respective SOA-MZI-based Row Access Gate (AG) to grant/block the entry of the incoming data words to the whole memory row. In case of a selected row, the data word exits the row AG and enters the respective CD that relies on an allpassive wavelength-selective Arrayed Waveguide Grating (AWG) for decoding the word bits into their individual columns. Both RD and CD procedures are carried out without requiring any active devices, assuming that the memory address and data word bits as well as their inverted values will be available in their optical form by the CPU interface. Proof-of-concept experimental verification exploiting cascaded pairs of AWGs as the λ-matrix is demonstrated at 10Gb/s, providing error-free operation with a peak power penalty lower than 0.2dB for all optical word channels.

  16. Proton computed tomography images with algebraic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzi, M. [Physics and Astronomy Department, University of Florence, Florence (Italy); Civinini, C.; Scaringella, M. [INFN - Florence Division, Florence (Italy); Bonanno, D. [INFN - Catania Division, Catania (Italy); Brianzi, M. [INFN - Florence Division, Florence (Italy); Carpinelli, M. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Presti, D. Lo [INFN - Catania Division, Catania (Italy); Physics and Astronomy Department, University of Catania, Catania (Italy); Maccioni, G. [INFN – Cagliari Division, Cagliari (Italy); Pallotta, S. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Randazzo, N. [INFN - Catania Division, Catania (Italy); Romano, F. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Sipala, V. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Talamonti, C. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Vanzi, E. [Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena (Italy)

    2017-02-11

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to ~1% and spatial resolutions <1 mm, achieved within processing times of ~15′ for a 512×512 pixels image prove that this technique will be beneficial if used instead of X-CT in hadron-therapy.

  17. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  18. The added value of 18F-fluorodeoxyglucose positron emission tomography computed tomography in patients with neck lymph node metastases from an unknown primary malignancy.

    Science.gov (United States)

    Prowse, S J B; Shaw, R; Ganeshan, D; Prowse, P M; Hanlon, R; Lewis-Jones, H; Wieshmann, H

    2013-08-01

    The search for a primary malignancy in patients with a metastatic cervical lymph node is challenging yet ultimately of utmost clinical importance. This study evaluated the efficacy of positron emission tomography computed tomography in detecting the occult primary, within the context of a tertiary referral centre head and neck cancer multidisciplinary team tumour board meeting. Thirty-two patients (23 men and 9 women; mean and median age, 61 years) with a metastatic cervical lymph node of unknown primary origin, after clinical examination and magnetic resonance imaging, underwent positron emission tomography computed tomography. The primary tumour detection rate was 50 per cent (16/32). Positron emission tomography computed tomography had a sensitivity of 94 per cent (16/17) and a specificity of 67 per cent (10/15). Combining these results with those of 10 earlier studies of similar patients gave an overall detection rate of 37 per cent. Positron emission tomography computed tomography has become an important imaging modality. To date, it has the highest primary tumour detection rate, for head and neck cancer patients presenting with cervical lymph node metastases from an unknown primary.

  19. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  20. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  1. Weightbearing Computed Tomography of the Foot and Ankle: Emerging Technology Topical Review.

    Science.gov (United States)

    Barg, Alexej; Bailey, Travis; Richter, Martinus; de Cesar Netto, Cesar; Lintz, François; Burssens, Arne; Phisitkul, Phinit; Hanrahan, Christopher J; Saltzman, Charles L

    2018-03-01

    In the last decade, cone-beam computed tomography technology with improved designs allowing flexible gantry movements has allowed both supine and standing weight-bearing imaging of the lower extremity. There is an increasing amount of literature describing the use of weightbearing computed tomography in patients with foot and ankle disorders. To date, there is no review article summarizing this imaging modality in the foot and ankle. Therefore, we performed a systematic literature review of relevant clinical studies targeting the use of weightbearing computed tomography in diagnosis of patients with foot and ankle disorders. Furthermore, this review aims to offer insight to those with interest in considering possible future research opportunities with use of this technology. Level V, expert opinion.

  2. Comparison of ultrasound and computer tomography in the diagnosis of pleural shadowing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Schmitt, W.G.H.

    1983-05-01

    Sonography was performed in 40 patients with pleural shadowing of uncertain origin in order to complement conventional X-ray examination. Where the findings were not clear-cut, computer tomography was performed subsequently and the diagnosis ascertained by biopsy or operation. Fluid-containing pleural lesions, such as encysted effusions and empyemas, pericardial cysts and one echinococcus cyst were identified by sonography from their appearance and biopsy was performed; computer tomography adds little additional information in these conditions. Solid pleural masses, on the other hand, can be more accurately defined by computer tomography. This shows the entire pleura, including small areas of calcification. Density measurements are able to differentiate various tissues, and particularly fat.

  3. Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Zimmermann, E.; Germershausen, C.; Hamm, B. [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schlattmann, P. [University Hospital of Friedrich-Schiller University Jena, Department of Medical Statistics, Computer Sciences and Documentation, Jena (Germany); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany)

    2012-01-15

    To obtain an overview of the current clinical practice of cardiac computed tomography (CT). A 32-item questionnaire was mailed to a total of 750 providers of cardiac CT in 57 countries. A total of 169 questionnaires from 38 countries were available for analysis (23%). Most CT systems used (94%, 207/221) were of the latest generation (64-row or dual-source CT). The most common indications for cardiac CT was exclusion of coronary artery disease (97%, 164/169). Most centres used beta blockade (91%, 151/166) and sublingual nitroglycerine (80%, 134/168). A median slice thickness of 0.625 mm with a 0.5-mm increment and an 18-cm reconstruction field of view was used. Interpretation was most often done using source images in orthogonal planes (92%, 155/169). Ninety percent of sites routinely evaluate extracardiac structures on a large (70%) or cardiac field of view (20%). Radiology sites were significantly more interested in jointly performing cardiac CT together with cardiology than cardiologists. The mean examination time was 18.6 {+-} 8.4 min, and reading took on average 28.7 {+-} 17.8 min. Cardiac CT has rapidly become established in clinical practice, and there is emerging consensus regarding indications, conduct of the acquisition, and reading. (orig.)

  4. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  5. Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    International Nuclear Information System (INIS)

    Sabour, Siamak; Rutten, A.; Schouw, Y. T. van der; Atsma, F.; Grobbee, D. E.; Mali, W. P.; Bartelink, M. E. L.; Bots, M. L.; Prokop, M.

    2007-01-01

    Purpose. To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables.Design. Cross-sectional study with repeated measurements. Materials and methods. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC).Results. Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements.Conclusion. Inter-scan reproducibility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

  6. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

    Science.gov (United States)

    Cros, Maria; Joemai, Raoul M. S.; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-08-01

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  7. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  8. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  9. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  10. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    Science.gov (United States)

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Computed tomography and childhood seizure disorder in Ibadan ...

    African Journals Online (AJOL)

    Computed tomography and childhood seizure disorder in Ibadan. ... neuroimaging, it offers an opportunity to investigate structural lesions as a cause of seizures ... The presence of neurologic deficit increased the yield of abnormal CT features.

  12. The clinical impact of high resolution computed tomography in patients with respiratory disease

    International Nuclear Information System (INIS)

    Screaton, Nicholas J.; Tasker, Angela D.; Flower, Christopher D.R.; Miller, Fiona N.A.C.; Patel, Bipen D.; Groves, Ashley; Lomas, David A.

    2011-01-01

    High resolution computed tomography is widely used to investigate patients with suspected diffuse lung disease. Numerous studies have assessed the diagnostic performance of this investigation, but the diagnostic and therapeutic impacts have received little attention. The diagnostic and therapeutic impacts of high resolution computed tomography in routine clinical practice were evaluated prospectively. All 507 referrals for high-resolution computed tomography over 12 months in two centres were included. Requesting clinicians completed questionnaires before and after the investigation detailing clinical indications, working diagnoses, confidence level in each diagnosis, planned investigations and treatments. Three hundred and fifty-four studies on 347 patients had complete data and were available for analysis. Following high-resolution computed tomography, a new leading diagnosis (the diagnosis with the highest confidence level) emerged in 204 (58%) studies; in 166 (47%) studies the new leading diagnosis was not in the original differential diagnosis. Mean confidence in the leading diagnosis increased from 6.7 to 8.5 out of 10 (p < 0.001). The invasiveness of planned investigations increased in 23 (7%) studies and decreased in 124 (35%) studies. The treatment plan was modified after 319 (90%) studies. Thoracic high-resolution computed tomography alters leading diagnosis, increases diagnostic confidence, and frequently changes investigation and management plans. (orig.)

  13. Computed tomography from photon statistics to modern cone-beam CT

    CERN Document Server

    Buzug, T M

    2008-01-01

    Tis book provides an overview of X-ray technology, the historic developmental milestones of modern CT systems, and gives a comprehensive insight into the main reconstruction methods used in computed tomography. Te basis of reconstr- tion is, undoubtedly, mathematics. However, the beauty of computed tomography cannot be understood without a detailed knowledge of X-ray generation, photon- matter interaction, X-ray detection, photon statistics, as well as fundamental signal processing concepts and dedicated measurement systems. Terefore, the reader will ?nd a number of references to these basic d

  14. Helical computed tomography and the workstation: introduction to a symbiosis

    International Nuclear Information System (INIS)

    Garcia-Santos, J.M.

    1997-01-01

    We do a brief introduction to the possibilities of an helical computed tomography system when it is associated with a powerful workstation. The fast and volumetric way of acquisition constitutes, basically, the main advantage of this sort of computed tomography. The anatomical and radio pathological study, in a workstation, of the acquired information (thanks to multiplanar and 3D reconstruction), increases significantly our capacity of analysis in each patient. Only the clinical and radiological experience will tell us which is the right place that this symbiosis occupies within our diagnosis tools. (Author) 11 refs

  15. Comparison between single-row and double-row rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Milano, Giuseppe; Grasso, Andrea; Zarelli, Donatella; Deriu, Laura; Cillo, Mario; Fabbriciani, Carlo

    2008-01-01

    The aim of this study was to compare the mechanical behavior under cyclic loading test of single-row and double-row rotator cuff repair with suture anchors in an ex-vivo animal model. For the present study, 50 fresh porcine shoulders were used. On each shoulder, a crescent-shaped full-thickness tear of the infraspinatus was performed. Width of the tendon tear was 2 cm. The lesion was repaired using metal suture anchors. Shoulders were divided in four groups, according the type of repair: single-row tension-free repair (Group 1); single-row tension repair (Group 2); double-row tension-free repair (Group 3); double-row tension repair (Group 4); and a control group. Specimens were subjected to a cyclic loading test. Number of cycles at 5 mm of elongation and at failure, and total elongation were calculated. Single-row tension repair showed significantly poorest results for all the variables considered, when compared with the other groups. Regarding the mean number of cycles at 5 mm of elongation and at failure, there was a nonsignificant difference between Groups 3 and 4, and both of them were significantly greater than Group 1. For mean total elongation, the difference between Groups 1, 3, and 4 was not significant, but all of them were significantly lower than the control group. A single-row repair is particularly weak when performed under tension. Double-row repair is significantly more resistant to cyclic displacement than single-row repair in both tension-free and tension repair. Double-row repair technique can be primarily considered for large, unstable rotator cuff tears to improve mechanical strength of primary fixation of tendons to bone.

  16. Cranial computed tomography in maple syrup urine disease

    International Nuclear Information System (INIS)

    Irnberger, T.; Ploechl, E.; Rittinger, O.; Bachmann, C.; Pilz, P.; Walter, G.F.; Wendel, U.; Landeskrankenanstalten Salzburg; Bern Univ.; Landesnervenklinik Salzburg; Graz Univ.; Dudley Observatory, Albany, NY; Duesseldorf Univ.

    1986-01-01

    Cranial computed tomography in the initial stage of the intermediate phenotype of maple syrup urine disease (MSUD) demonstrates diffuse, symmetric hypodensities in white and grey matter, which show a complete return to normal after early introduction of an adequate protein-restrictive diet. If diagnosis of this disease is missed or delayed, progressive global (end-stage) atrophy will take place over several years. A decrease in density values correlates well with the total cerebral lipid and water content (closely related to myelinisation), whereas progression and grade of atrophy show a relationship with the severity of pathological white and grey matter changes that are not demonstrable with computed tomography but can be proven histologically. Analysis of both morphological parameters corresponds well with clinical-neurological outcome and therapeutic success. (orig.) [de

  17. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  18. The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.

    Science.gov (United States)

    Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A

    2012-08-01

    Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair becomes the more cost-effective surgical option. The identification of the threshold values in this study may help surgeons to determine the most cost-effective treatment.

  19. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  20. Solitary pulmonary metastases in high-risk melanoma patients: a prospective comparison of conventional and computed tomography

    International Nuclear Information System (INIS)

    Heaston, D.K.; Putman, C.E.; Rodan, B.A.; Nicholson, E.; Ravin, C.E.; Korobkin, M.; Chen, J.T.; Seigler, H.F.

    1983-01-01

    A prospective comparison of chest radiography, conventional tomography, and computed tomography (CT) in the detection or confirmation of solitary pulmonary nodules was made in 42 patients with high propensity for pulmonary metastases due to advanced local (Clark level IV or V) or regional malignant melanoma. Unequivocal nodules were revealed by chest radiography in 11 patients, conventional tomograhy in 16, and computed tomography in 20 patients. Both plain films and tomography in three of these 20 were normal, but follow-up verified pulmonary metastases. Computed tomography detected more pulmonary nodules than conventional tomography in 11 patients in addition to identifying lesions in extrapulmonary sites. Therefore, chest CT is recommended before institution of immunotherapy or surgical removal of a solitary pulmonary melanoma metastasis. Once chemotherapy had been instituted for bulky regional or cutaneous involvement, however, the findings of either conventional or computed tomography were comparable in this study

  1. A comparative clinical evaluation of arthroscopic single-row versus double-row supraspinatus tendon repair.

    Science.gov (United States)

    Buess, Eduard; Waibl, Bernhard; Vogel, Roger; Seidner, Robert

    2009-10-01

    Cadaveric studies and commercial pressure have initiated a strong trend towards double-row repair in arthroscopic cuff surgery. The objective of this study was to evaluate if the biomechanical advantages of a double-row supraspinatus tendon repair would result in superior clinical outcome and higher abduction strength. A retrospective study of two groups of 32 single-row and 33 double-row repairs of small to medium cuff tears was performed. The Simple Shoulder Test (SST) and a visual analog scale for pain were used to evaluate the outcome. The participation rate was 100%. A subset of patients was further investigated with the Constant Score (CS) including electronic strength measurement. The double-row repair patients had significantly more (p = 0.01) yes answers in the SST than the single-row group, and pain reduction was slightly better (p = 0.03). No difference was found for the relative CS (p = 0.86) and abduction strength (p = 0.74). Patient satisfaction was 100% for double-row and 97% for single-row repair. Single- and double-row repairs both achieved excellent clinical results. Evidence of superiority of double-row repair is still scarce and has to be balanced against the added complexity of the procedure and higher costs.

  2. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  3. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  4. Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography.

    Science.gov (United States)

    Varshowsaz, Masoud; Goorang, Sepideh; Ehsani, Sara; Azizi, Zeynab; Rahimian, Sepideh

    2016-03-01

    Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (HUs) in CBCT and CT scans of different tissue phantoms with two different thicknesses, two different image acquisition settings and in three locations in the phantoms. Four different tissue phantoms namely hard tissue, soft tissue, air and water were scanned by three different CBCT and a CT system in two thicknesses (full and half) and two image acquisition settings (high and low kVp and mA). The images were analyzed at three sites (middle, periphery and intermediate) using eFilm software. The difference in density values was analyzed by ANOVA and correction coefficient test (P<0.05). There was a significant difference between density values in CBCT and CT scans in most situations, and CBCT values were not similar to CT values in any of the phantoms in different thicknesses and acquisition parameters or the three different sites. The correction coefficients confirmed the results. CBCT is not reliable for tissue density assessment. The results were not affected by changes in thickness, acquisition parameters or locations.

  5. Clinical applications of the computed tomography of the thorax

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Eun; Kim, Ho Kyun; Kim, Soon Yong [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1980-06-15

    The computed tomography of the thorax has had considerably less impact in patient management than that of head and abdomen, because the convention chest radiography is a much more sensitive and accurate examination than the plain film studies of the head and abdomen. It has progressively been identified that the computed tomography of chest is superior to the conventional radiography in detection of small pulmonary nodules including occult metastatic lesions, in evaluation of character of hilar enlargement, and in staging of known bronchogenic caner. And especially in mediastinum, the computed tomography is supported to the any other conventional radiography in outlining lesions and determining character and extent of lesions. At the department of radiology, Kyung Hee University Hospital , 87 cases of computed tomography of chest were performed with EMI-CT 5005 whole-body scanner from October 1977 to August 1979. The results were as following; 1. The fifty eight cases of considered to be pathologic findings were 23 pleural thickening and/or effusion, 14 bronchogenic carcinoma, 8 inflammatory lesions of lung parenchyme, 6 mediastinal lesions, 3 metastinal lesions, 3 COPD, 1 trauma, respectively. 2. No gravity-dependent change was noted in patients with chronic obstructive pulmonary disease (COPD), which was frequently seen in normal subjects. Diminished numbers of pulmonary vessels was noted in COPD. 3. Small nodules in lung, retrosternal, posterior costophrenic and subpleural regions, which were not found on conventional radiography, can be detected by chest CT. 4. Differentiation of dilated central pulmonary artery from pulmonary mass in enlarged hilum and determination of adjacent mediastinal invasion, manifested by obliterated fat plane, was possible. 5. The cases of mediastinal widening such as paraspinal ilpomatosis, pericardial fat pad, teratoma, and bronchogenic cyst were easily determined by means of measuring the attenuation coefficiencies. 6. Small amount

  6. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    Science.gov (United States)

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  7. Clinical applications of the computed tomography of the thorax

    International Nuclear Information System (INIS)

    Hong, Seong Eun; Kim, Ho Kyun; Kim, Soon Yong

    1980-01-01

    The computed tomography of the thorax has had considerably less impact in patient management than that of head and abdomen, because the convention chest radiography is a much more sensitive and accurate examination than the plain film studies of the head and abdomen. It has progressively been identified that the computed tomography of chest is superior to the conventional radiography in detection of small pulmonary nodules including occult metastatic lesions, in evaluation of character of hilar enlargement, and in staging of known bronchogenic caner. And especially in mediastinum, the computed tomography is supported to the any other conventional radiography in outlining lesions and determining character and extent of lesions. At the department of radiology, Kyung Hee University Hospital , 87 cases of computed tomography of chest were performed with EMI-CT 5005 whole-body scanner from October 1977 to August 1979. The results were as following; 1. The fifty eight cases of considered to be pathologic findings were 23 pleural thickening and/or effusion, 14 bronchogenic carcinoma, 8 inflammatory lesions of lung parenchyme, 6 mediastinal lesions, 3 metastinal lesions, 3 COPD, 1 trauma, respectively. 2. No gravity-dependent change was noted in patients with chronic obstructive pulmonary disease (COPD), which was frequently seen in normal subjects. Diminished numbers of pulmonary vessels was noted in COPD. 3. Small nodules in lung, retrosternal, posterior costophrenic and subpleural regions, which were not found on conventional radiography, can be detected by chest CT. 4. Differentiation of dilated central pulmonary artery from pulmonary mass in enlarged hilum and determination of adjacent mediastinal invasion, manifested by obliterated fat plane, was possible. 5. The cases of mediastinal widening such as paraspinal ilpomatosis, pericardial fat pad, teratoma, and bronchogenic cyst were easily determined by means of measuring the attenuation coefficiencies. 6. Small amount

  8. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  9. Significance of a postenhancement computed tomography findings in liver cirrhosis: In view of hemodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suck Hong; Kim, Byung Soo [Pusan National University College of Medicine, Pusan (Korea, Republic of)

    1985-04-15

    We observed a significant sign in postenhancement computed tomography of liver cirrhosis, that is visualization of portal venous branches. During postenhancement computed tomography scanning of liver, the portal vein can not be identified in liver parenchyme in 84% of patients without known cirrhosis (including chronic active hepatitis). The two have the same hemodynamic changes in that there is diffuse fibrosis and resultant decrease in vascular bed. Visualization of intrahepatic portal branches in postenhancement computed tomography is because of decreased diffusion ability and portal hypertension.

  10. Incidence of traumatic carotid and vertebral artery dissections: results of cervical vessel computed tomography angiogram as a mandatory scan component in severely injured patients

    Directory of Open Access Journals (Sweden)

    Schicho A

    2018-01-01

    Full Text Available Andreas Schicho,1 Lukas Luerken,1 Ramona Meier,1 Antonio Ernstberger,2 Christian Stroszczynski,1 Andreas Schreyer,1 Lena-Marie Dendl,1 Stephan Schleder1 1Department of Radiology, 2Department of Trauma Surgery, University Medical Center, Regensburg, Germany Purpose: The aim of this study was to evaluate the true incidence of cervical artery dissections (CeADs in trauma patients with an Injury Severity Score (ISS of ≥16, since head-and-neck computed tomography angiogram (CTA is not a compulsory component of whole-body trauma computed tomography (CT protocols. Patients and methods: A total of 230 consecutive trauma patients with an ISS of ≥16 admitted to our Level I trauma center during a 24-month period were prospectively included. Standardized whole-body CT in a 256-detector row scanner included a head-and-neck CTA. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded and analyzed retrospectively in patients with carotid artery dissection (CAD and vertebral artery dissection (VAD. Results: Of the 230 patients included, 6.5% had a CeAD, 5.2% had a CAD, and 1.7% had a VAD. One patient had both CAD and VAD. For both, CAD and VAD, mortality is 25%. One death was caused by fatal cerebral ischemia due to high-grade CAD. A total of 41.6% of the patients with traumatic CAD and 25% of the patients with VAD had neurological sequelae. Conclusion: Mandatory head-and-neck CTA yields higher CeAD incidence than reported before. We highly recommend the compulsory inclusion of a head-and-neck CTA to whole-body CT routines for severely injured patients. Keywords: polytrauma, carotid artery, vertebral artery, dissection, blunt trauma, computed tomography angiogram

  11. Computed tomography manifestations of peritoneal diseases

    International Nuclear Information System (INIS)

    Gordon, K.; Lee, W.K.; Hennessy, O.

    2005-01-01

    The peritoneal cavity is a potential space that is divided by the peritoneal reflections into various complex subspaces. It can be involved in many disease processes including developmental, inflammatory, neoplastic and traumatic conditions. Computed tomography is highly sensitive and consistent in detecting peritoneal pathology. This pictorial essay aims to emphasize and illustrate the CT features of the spectrum of peritoneal diseases. Copyright (2005) Blackwell Science Pty Ltd

  12. Under-reporting of osteoporotic vertebral fractures on computed tomography

    International Nuclear Information System (INIS)

    Williams, Alexandra L.; Al-Busaidi, Aisha; Sparrow, Patrick J.; Adams, Judith E.; Whitehouse, Richard W.

    2009-01-01

    Purpose: Osteoporotic vertebral fractures are frequently asymptomatic. They are often not diagnosed clinically or radiologically. Despite this, prevalent osteoporotic vertebral fractures predict future osteoporotic fractures and are associated with increased mortality and morbidity. Appropriate management of osteoporosis can reduce future fracture risk. Fractures on lateral chest radiographs taken for other conditions are frequently overlooked by radiologists. Our aim was to assess the value of computed tomography (CT) in the diagnosis of vertebral fracture and identify the frequency with which significant fractures are missed. Materials and methods: The thoracic CT scans of 100 consecutive male and 100 consecutive female patients over 55 years were reviewed. CT images were acquired on General Electric Lightspeed multi-detector (MD) CT scanners (16 or 32 row) using 1.25 mm slice thickness. Midline sagittal images were reconstructed from the 3D volume images. The presence of moderate (25-40% height loss) or severe (>40% height loss) vertebral fractures between T1 and L1 was determined using an established semi-quantitative method and confirmed by morphological measurement. Results were compared with the formal CT report. Results: Scans of 192 patients were analysed (95 female; 97 male); mean age 70.1 years. Thirty-eight (19.8%) patients had one or more moderate to severe vertebral fractures. Only 5 (13%) were correctly reported as having osteoporotic fractures in the official report. The sensitivity of axial CT images to vertebral fracture was 0.35. Conclusion: Incidental osteoporotic vertebral fractures are under-reported on CT. The sensitivity of axial images in detecting these fractures is poor. Sagittal reformations are strongly recommended to improve the detection rate

  13. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  14. Estimation of computed tomography dose index in cone beam computed tomography: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald

    2010-05-01

    To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry.

  15. Effect of computed tomography noise and tissue heterogeneity on cerebral blood flow determination by xenon-enhanced computed tomography

    International Nuclear Information System (INIS)

    Good, W.F.; Gur, D.

    1987-01-01

    The errors associated with derivation of cerebral blood flow values by the xenon-enhanced computed tomography (CT) method have been evaluated as a function of tissue heterogeneity and CT noise. The results of this study indicate that CT noise introduces large errors in the derived flow value when data for a single, unprocessed voxel are used for this purpose. CT noise increases the derived flow values in a systematic way. Tissue heterogeneity results in a systematic error which lowers the derived flow values. Errors due to both parameters are computed for typical and extreme conditions

  16. Analysis of the computed tomography in the acute abdomen; Analise da tomografia computadorizada no abdome agudo

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil); Moraes, Everton [Universidade Federal de Santa Maria (UFSM), RS (Brazil); Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase [Hospital Universitario de Santa Maria, RS (Brazil); Gazzoni, Fernando [Pontificia Universidade Catolica de Porto Alegre (PUC-RS), Porto Alegre, RS (Brazil). Hospital Sao Lucas; Andrade, Rubens Gabriel Feijo [Fundacao Universitaria de Cardiologia de Porto Alegre, RS (Brazil). Inst. de Cardiologia; Bueno, Leticia Rossi [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil); Lopes, Luis Felipe Dias [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Dept. de Estatistica]. E-mail: brunorgs@pop.com.br

    2007-07-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p < 0.05), and the confidence index in 85.71% of the cases (p 0.014). Computed tomography also altered the management in 46.43% of the cases (p > 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  17. Computed tomography in the evaluation of trauma

    International Nuclear Information System (INIS)

    Federle, M.P.; Brant-Zawadzki, M.

    1982-01-01

    This book is intended to be the current standard for computed tomography in the evaluation of trauma. It summarizes two years of experience at San Francisco General Hospital. The book is organized into seven chapters, covering head, maxillofacial, laryngeal, spinal, chest, abdominal, acetabular, and pelvic trauma. Extremity trauma is not discussed

  18. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  19. CASE SERIES Multi-detector computer tomography venography ...

    African Journals Online (AJOL)

    in the curved coronal plane with particular reference to the course of the common and external iliac veins through the pelvis. Axial venous. Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with ...

  20. Report of two cases of fluorodeoxyglucose positron emission tomography/computed tomography appearance of hibernoma: A rare benign tumor

    International Nuclear Information System (INIS)

    Agrawal, Archi; Kembhavi, Seema; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2014-01-01

    False-positive findings are commonly seen in positron emission tomography computed tomography imaging. One of the most common false positive finding is uptake of fluorodeoxyglucose in brown adipose tissue. Herein, we report two cases with incidentally detected hibernomas-a brown fat containing tumor with metabolic activity