  1. Detecting Mycobacterium tuberculosis in Bactec MGIT 960 Cultures by Inhouse IS6110-based PCR Assay in Routine Clinical Practice

    Directory of Open Access Journals (Sweden)

    Jun-Ren Sun

    2009-02-01

    Conclusion: The combined use of the automated Bactec MGIT 960 system and the IS6110-based PCR assay is sensitive and rapid for the detection of M. tuberculosis complex, and we recommend that this method be used routinely for identification of mycobacteria in clinical laboratories.

  2. Post-standardization of routine creatinine assays: are they suitable for clinical applications.

    Science.gov (United States)

    Jassam, Nuthar; Weykamp, Cas; Thomas, Annette; Secchiero, Sandra; Sciacovelli, Laura; Plebani, Mario; Thelen, Marc; Cobbaert, Christa; Perich, Carmen; Ricós, Carmen; Paula, Faria A; Barth, Julian H

    2017-05-01

    Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239  μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100  μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility

  3. Point of Care Cardiac Troponin Assay Analytical Performances for their Use in Clinical Routine.

    Science.gov (United States)

    Dupuy, Anne M; Baillet, Solenne; Dumont, Richard; Giraud, Isabelle; Badiou, Stephanie; Bargnoux, Anne S; Kuster, Nils; Roubille, Francois; Cristol, Jean Paul

    2017-04-01

    We report the analytical and clinical performances of the Alere Triage Cardiac3© Panel on the Triage MeterPro© instrument, comparing concordance with hs-cTnT results from central laboratory above the respective 99th percentiles and determining the clinical sensitivity within the framework of AMI. The concordance was obtained with these two methods among unselected patients admitted to both the emergency and cardiology departments. The LoD of the assay is 0.010 µg/L. At 99th percentile (0.02 µg/L) the CV was found to be 18%, below the clinically acceptable cutoff of 20%. In the overall population, ROC AUC was not significantly different between the central laboratory assay and POC assay, with 0.952 (95% CI, 0.918 - 0.952) for hs-cTnT concentrations at presentation and 0.953 (95% CI, 0.912 - 0.953) for cTnI. Sensitivity and specificity of hs-cTnT vs. cTnI for AMI (n = 32) were 97% and 78% vs. 91% and 86%, respectively. Our results indicated 90.4% concordance between the two methods using the 99th percentile specific for each assay. The Kappa coefficient was higher than 0.75, and the strength of agreement could be considered to be good. The results of cTnI Alere assays provide similar clinical classification of patients, particularly for the AMI group as compared to the central laboratory hs-cTnT assay and could be suitable for clinical in accordance with the recommendations of Global Task Force guidelines.

  4. Routine pharmacogenetic testing in clinical practice: dream or reality?

    Science.gov (United States)

    Grossman, Iris

    2007-10-01

    Pharmacogenetics (PGx) has become progressively popular in recent years, thanks to growing anticipation among scientists, healthcare providers and the general public for the incorporation of genetic tests into the diagnostic arsenal at the physician's disposal. Indeed, much research has been dedicated to elucidation of genetic determinants underlying interindividual variability in pharmacokinetic parameters, as well as drug safety and efficacy. However, few PGx applications have thus far been realized in healthcare management. This review uses examples from PGx research of psychiatric drugs to illustrate why the current published findings are inadequate and insufficient for utilization as routine clinical predictors of treatment safety, efficacy or dosing. I therefore suggest the necessary steps to demonstrate the validity, utility and cost-effectiveness of PGx. These recommendations include a whole range of aspects, starting from standardization of criteria and assessment of the technical quality of genotyping assays, up to design of prospective PGx studies, providing the basis for reimbursement programs to be recognized in routine clinical practice.

  5. Radioligand purification prior to routine receptor assays

    International Nuclear Information System (INIS)

    Le Goff, J.-M.; Berthois, Y.; Martin, P.-M.

    1988-01-01

    The need to repurify the commercially available radioligands [ 3 H]estradiol and [ 3 H]testosterone before use in routine assays was investigated. Storage of these products for 2 months after delivery led to appreciable degradation of [ 3 H]estradiol compared to [ 3 H]testosterone. Unexpectedly, TLC and even HPLC procedures were ineffective in completely restoring the purity of [ 3 H]-estradiol and the unremoved polar products induced important variations in our estrogen receptor assays. An increase in non-specific binding and a concomitant decrease in total binding were observed resulting in an underestimation of specific binding sites and of the affinity constant. In some cases Scatchard analysis was not possible. The authors therefore strongly recommend the repurification of low-stability radioligands and propose an economic time-saving procedure for the purification of [ 3 H]estradiol by solvent differential partition which requires no high-cost investment in apparatus. (author)

  6. Taking a new biomarker into routine use – A perspective from the routine clinical biochemistry laboratory

    Science.gov (United States)

    Sturgeon, Catharine; Hill, Robert; Hortin, Glen L; Thompson, Douglas

    2010-01-01

    There is increasing pressure to provide cost-effective healthcare based on “best practice.” Consequently, new biomarkers are only likely to be introduced into routine clinical biochemistry departments if they are supported by a strong evidence base and if the results will improve patient management and outcome. This requires convincing evidence of the benefits of introducing the new test, ideally reflected in fewer hospital admissions, fewer additional investigations and/or fewer clinic visits. Carefully designed audit and cost-benefit studies in relevant patient groups must demonstrate that introducing the biomarker delivers an improved and more effective clinical pathway. From the laboratory perspective, pre-analytical requirements must be thoroughly investigated at an early stage. Good stability of the biomarker in relevant physiological matrices is essential to avoid the need for special processing. Absence of specific timing requirements for sampling and knowledge of the effect of medications that might be used to treat the patients in whom the biomarker will be measured is also highly desirable. Analytically, automation is essential in modern high-throughput clinical laboratories. Assays must therefore be robust, fulfilling standard requirements for linearity on dilution, precision and reproducibility, both within- and between-run. Provision of measurements by a limited number of specialized reference laboratories may be most appropriate, especially when a new biomarker is first introduced into routine practice. PMID:21137030

  7. Routine clinical application of the FRAXA Pfu PCR assay: limits and utility.

    Science.gov (United States)

    Condorelli, D F; Milana, G; Dell'Albani, P; Roccazzello, A M; Insirello, E; Pavone, L; Mollica, F

    1996-11-01

    Fragile X genotype is characterized by the excessive amplification of an unstable region of DNA: a trinucleotide repeat CGG of variable copy number present in the FRAXA locus. Methods based on polymerase chain reaction (PCR) amplification of the CGG repeat region could facilitate the development of a rapid screening assay. Unfortunately, amplification across CGG repeats can be inefficient and unreliable due to their 100% G + C base composition. The utility of the exonuclease-deficient Pfu polymerase for amplification and detection of the CGG repeats at the FRAXA locus has been reported. In the present study we analysed the utility of a Pfu PCR assay as a rapid initial screening method to rule out a diagnosis of fragile X syndrome in males with mental retardation. Affected males did not show any amplification products or a smear of amplification products between 350 and 550 bp. Only 10% of affected male samples did not show any amplification products, while the vast majority showed the amplification smear. The amplification smears represent a serious drawback of the method, since they cannot be distinguished from the amplification products of normal samples after separation in 1% agarose gel. Several modifications of the PCR conditions were attempted to eliminate this problem, but none was appropriate for clinical applications. However, the problem was easily solved by using a higher resolution electrophoretic system that allows a clear distinction of normal bands from pathological smears. We tested the specificity of the Pfu PCR assay, followed by an improved MetaPhor gel electrophoretic separation of PCR products, on 50 samples from normal males and 24 samples form affected males. The results showed that this method is a rapid, sensitive and specific assay for the exclusion of fragile X syndrome diagnosis in mentally retarded males.

  8. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    Science.gov (United States)

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  9. Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture.

    Science.gov (United States)

    Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka

    2015-05-01

    Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.

  10. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  11. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    Science.gov (United States)

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection.

    Science.gov (United States)

    Kremastinou, J; Polymerou, V; Lavranos, D; Aranda Arrufat, A; Harwood, J; Martínez Lorenzo, M J; Ng, K P; Queiros, L; Vereb, I; Cusini, M

    2016-09-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. Copyright © 2016 Kremastinou et al.

  13. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

    Science.gov (United States)

    Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.

    2016-01-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468

  14. An interferon-gamma release assay test performs well in routine screening for tuberculosis

    DEFF Research Database (Denmark)

    Vestergaard Danielsen, Allan; Fløe, Andreas; Lillebæk, Troels

    2014-01-01

    Introduction: A positive interferon-gamma release assay (IGRA) is regarded as proof of latent Mycobacterium tuberculosis infection. We conducted an evaluation of the IGRA test “T-SPOT.TB” to test its performance during clinical routine use by analysing the positivity rate and odds, effect of season...... and sensitivity. Material and methods: Data from T-SPOT.TB testing together with age and test indications (anti-tumour necrosis factor alpha (TNFα) candidate, contact investigation or suspicion of tuberculosis (TB)) were combined with mycobac­teria culture results. Results: A total of 1,809 patients were tested....... Conclusive results were achieved for 1,780 patients (98.4%). Among these, 4.6% of anti-TNFα candidates, 19.3% of contacts and 24.4% of TB suspects tested positive. Compared with anti-TNFα candidates, the odds for a positive result were significantly higher for contact investigations (odds ratio (OR), mean...

  15. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  16. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays

    OpenAIRE

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2015-01-01

    BACKGROUND: We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. METHODS: Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automat...

  17. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Science.gov (United States)

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  18. Evaluation of the Clinical Performance of the HPV-Risk Assay Using the VALGENT-3 Panel.

    Science.gov (United States)

    Polman, N J; Oštrbenk, A; Xu, L; Snijders, P J F; Meijer, C J L M; Poljak, M; Heideman, D A M; Arbyn, M

    2017-12-01

    Human papillomavirus (HPV) testing is increasingly being incorporated into cervical cancer screening. The Validation of HPV Genotyping Tests (VALGENT) is a framework designed to evaluate the clinical performance of various HPV tests relative to that of the validated and accepted comparator test in a formalized and uniform manner. The aim of this study was to evaluate the clinical performance of the HPV-Risk assay with samples from the VALGENT-3 panel and to compare its performance to that of the clinically validated Hybrid Capture 2 assay (HC2). The VALGENT-3 panel comprises 1,300 consecutive samples from women participating in routine cervical cancer screening and is enriched with 300 samples from women with abnormal cytology. DNA was extracted from original ThinPrep PreservCyt medium aliquots, and HPV testing was performed using the HPV-Risk assay by investigators blind to the clinical data. HPV prevalence was analyzed, and the clinical performance of the HPV-Risk assay for the detection of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) and CIN2 or worse (CIN2+) relative to the performance of HC2 was assessed. The sensitivity of the HPV-Risk assay for the detection of CIN3+ was similar to that of HC2 (relative sensitivity, 1.00; 95% confidence interval [CI], 0.95 to 1.05; P = 1.000), but the specificity of the HPV-Risk assay was significantly higher than that of HC2 (relative specificity, 1.02; 95% CI, 1.01 to 1.04; P performance of the HPV-Risk assay for the detection of CIN3+ and CIN2+ was noninferior to that of HC2, with all P values being ≤0.006. In conclusion, the HPV-Risk assay demonstrated noninferiority to the clinically validated HC2 by the use of samples from the VALGENT-3 panel for test validation and comparison. Copyright © 2017 Polman et al.

  19. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study

    OpenAIRE

    ?uhadar, Serap; K?seo?lu, Mehmet; ?inpolat, Yasemin; Bu?dayc?, G?ler; Usta, Murat; Semerci, Tuna

    2016-01-01

    Abstract Introduction: Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L. Materials and methods: Base...

  20. Evaluation of the Roche prototype 454 HIV-1 ultradeep sequencing drug resistance assay in a routine diagnostic laboratory.

    Science.gov (United States)

    Garcia-Diaz, A; Guerrero-Ramos, A; McCormick, A L; Macartney, M; Conibear, T; Johnson, M A; Haque, T; Webster, D P

    2013-10-01

    Studies have shown that low-frequency resistance mutations can influence treatment outcome. However, the lack of a standardized high-throughput assay has precluded their detection in clinical settings. To evaluate the performance of the Roche prototype 454 UDS HIV-1 drug resistance assay (UDS assay) in a routine diagnostic laboratory. 50 plasma samples, previously characterized by population sequencing and that had shown ≥1 resistance associated mutation (RAM), were retrospectively tested by the UDS assay, including 18 B and 32 non-B subtypes; viral loads between 114-1,806,407 cp/ml; drug-naive (n=27) and drug-experienced (n=23) individuals. The UDS assay was successful for 37/50 (74%) samples. It detected all RAMs found by population sequencing at frequencies above 20%. In addition, 39 low-frequency RAMs were exclusively detected by the UDS assay at frequencies below 20% in both drug-naïve (19/26, 73%) and drug-experienced (9/18, 50%) individuals. UDS results would lead to changes from susceptible to resistant to efavirenz (EFV) in one drug-naive individual with suboptimal response to an EFV-containing regimen and from susceptible to resistance to lamivudine (3TC) in one drug naïve subject who subsequently failed a 3TC-containing regimen and in a treatment experienced subject who had failed a 3TC-containing regimen. The UDS assay performed well across a wide range of subtypes and viral loads; it showed perfect agreement with population sequencing for all RAMs analyzed. In addition, the UDS assay detected additional mutations at frequencies below 20% which correlate with patients' treatment history and had in some cases important prognostic implications. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Clinical validation of the Tempus xO assay

    Science.gov (United States)

    Beaubier, Nike; Tell, Robert; Huether, Robert; Bontrager, Martin; Bush, Stephen; Parsons, Jerod; Shah, Kaanan; Baker, Tim; Selkov, Gene; Taxter, Tim; Thomas, Amber; Bettis, Sam; Khan, Aly; Lau, Denise; Lee, Christina; Barber, Matthew; Cieslik, Marcin; Frankenberger, Casey; Franzen, Amy; Weiner, Ali; Palmer, Gary; Lonigro, Robert; Robinson, Dan; Wu, Yi-Mi; Cao, Xuhong; Lefkofsky, Eric; Chinnaiyan, Arul; White, Kevin P.

    2018-01-01

    We have developed a clinically validated NGS assay that includes tumor, germline and RNA sequencing. We apply this assay to clinical specimens and cell lines, and we demonstrate a clinical sensitivity of 98.4% and positive predictive value of 100% for the clinically actionable variants measured by the assay. We also demonstrate highly accurate copy number measurements and gene rearrangement identification. PMID:29899824

  2. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study.

    Science.gov (United States)

    Çuhadar, Serap; Köseoğlu, Mehmet; Çinpolat, Yasemin; Buğdaycı, Güler; Usta, Murat; Semerci, Tuna

    2016-01-01

    Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L. Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically. Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference. Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.

  3. Comparison of radioassay and microbiological assay for serum folate, with clinical assessment of discrepant results

    International Nuclear Information System (INIS)

    Baril, L.; Carmel, R.

    1978-01-01

    Folate assays by use of radiolabeled folate provide obvious practical advantages over the standard microbiological assay, but remain incompletely tested. We therefore compared results for 415 sera with a kit involving 3 H-labeled folate and the Lactobacillus casei microbiological method. We examined the patients' data when there were discrepancies between the two methods. Although the correlation overall was satisfactory, results were discrepant in 25% of cases. In 74% of the latter, the radioassay result appeared to be the correct one, primarily because L. casei results were suppressed by antibiotics being taken by the patient. The radioassay occasionally gave falsely high values for patients with liver disease and falsely low ones for patients who had received isotopes for scanning purposes. Several assay kits that make use of 125 I- or 75 Se-labeled folate were also tested. Although these results correlated with the results of 3 H-labeled folate assay, various problems appeared, including the possible need for serum-supernate control tubes in one kit. Answers to these and other questions and careful clinical correlation of results are needed for any folate radioassays before their adoption for routine clinical use

  4. Mould routine identification in the clinical laboratory by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Carole Cassagne

    Full Text Available BACKGROUND: MALDI-TOF MS recently emerged as a valuable identification tool for bacteria and yeasts and revolutionized the daily clinical laboratory routine. But it has not been established for routine mould identification. This study aimed to validate a standardized procedure for MALDI-TOF MS-based mould identification in clinical laboratory. MATERIALS AND METHODS: First, pre-extraction and extraction procedures were optimized. With this standardized procedure, a 143 mould strains reference spectra library was built. Then, the mould isolates cultured from sequential clinical samples were prospectively subjected to this MALDI-TOF MS based-identification assay. MALDI-TOF MS-based identification was considered correct if it was concordant with the phenotypic identification; otherwise, the gold standard was DNA sequence comparison-based identification. RESULTS: The optimized procedure comprised a culture on sabouraud-gentamicin-chloramphenicol agar followed by a chemical extraction of the fungal colonies with formic acid and acetonitril. The identification was done using a reference database built with references from at least four culture replicates. For five months, 197 clinical isolates were analyzed; 20 were excluded because they were not identified at the species level. MALDI-TOF MS-based approach correctly identified 87% (154/177 of the isolates analyzed in a routine clinical laboratory activity. It failed in 12% (21/177, whose species were not represented in the reference library. MALDI-TOF MS-based identification was correct in 154 out of the remaining 156 isolates. One Beauveria bassiana was not identified and one Rhizopus oryzae was misidentified as Mucor circinelloides. CONCLUSIONS: This work's seminal finding is that a standardized procedure can also be used for MALDI-TOF MS-based identification of a wide array of clinically relevant mould species. It thus makes it possible to identify moulds in the routine clinical laboratory setting

  5. Very poor agreement between routine outpatient clinic office and ambulatory blood pressure: time to improve an old hospital outpatient clinic routine?

    Science.gov (United States)

    Reinhard, Mark; Poulsen, Per L; Christensen, Kent L

    2016-12-01

    We investigated the agreement between elevated outpatient clinic office blood pressure (OC-OBP) as measured in the daily routine in our University Hospital Cardiology Outpatient Clinic and subsequent awake ambulatory blood pressure (AABP). In all patients referred for ambulatory blood pressure monitoring from our Cardiology Outpatient Clinic, we identified OC-OBP and changes in medication in the period from 1 January 2014 to 15 September 2015. The AABP was used as a reference measurement for the OC-OBP. A total of 183 patients were included in the study. Their mean age was 62.1±14.0 years and 49% were women. The mean systolic OC-OBP was 166.8±17.9 mmHg and the difference between the mean systolic OC-OBP and AABP was 28.0±19.5 mmHg (Pclinic agrees poorly with AABP and may lead to unnecessary treatment and pharmacologically induced symptomatic hypotension, particularly in elderly patients. The results of this study urgently call for alternative solutions to routine OC-OBP in hospital outpatient clinics.

  6. A comparison between the efficiency of the Xpert MTB/RIF assay and nested PCR in identifying Mycobacterium tuberculosis during routine clinical practice.

    Science.gov (United States)

    Kim, Cheol-Hong; Woo, Heungjeong; Hyun, In Gyu; Kim, Changhwan; Choi, Jeong-Hee; Jang, Seung-Hun; Park, Sang Myeon; Kim, Dong-Gyu; Lee, Myung Goo; Jung, Ki-Suck; Hyun, Jeongwon; Kim, Hyun Soo

    2014-06-01

    Polymerase chain reaction (PCR) for the detection of Mycobacterium tuberculosis (MTB) is more sensitive, specific, and rapid than the conventional methods of acid-fast bacilli (AFB) smear and culture. The aim of this study was to determine if the Xpert MTB/rifampicin (RIF) assay had additional advantages over nested PCR for the detection of MTB in a geographical area with intermediate tuberculosis (TB) incidence. Between February and December 2013, the Xpert MTB/RIF assay and MTB nested PCR, as well as AFB smear and culture, were simultaneously performed on 198 clinical samples (160 pulmonary and 38 non-pulmonary specimens) collected from 171 patients hospitalized at Hallym University Medical Center for possible TB. The accuracy of the diagnosis of MTB culture-positive TB and the turnaround time of reporting laboratory results were calculated and compared. Rifampin resistance by the Xpert MTB/RIF assay was reviewed with that of conventional drug susceptibility testing (DST). The sensitivity, specificity, and positive and negative predictive values of the Xpert MTB/RIF assay and MTB nested PCR for diagnosis of MTB culture-positive pulmonary TB were 86.1% vs. 69.4% (P=0.1563), 97.8% vs. 94.1% (P=0.2173), 91.2% vs. 75.8% (P=0.1695), and 96.4% vs. 92.0% (P=0.2032), respectively. The median turnaround times of the Xpert MTB/RIF assay and MTB nested PCR were 0 [0-4] days and 4 [1-11] days, respectively (Pnested PCR for identifying MTB among clinically suspected TB patients, and the assay can be valuable in giving a timely identification of resistance to rifampin.

  7. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  8. Stratification of type 2 diabetes based on routine clinical markers

    DEFF Research Database (Denmark)

    Safai, Narges; Ali, Ashfaq; Rossing, Peter

    2018-01-01

    AIMS: We hypothesized that patients with dysregulated type 2 diabetes may be stratified based on routine clinical markers. METHODS: In this retrospective cohort study, diabetes related clinical measures including age at onset, diabetes duration, HbA1c, BMI, HOMA2-β, HOMA2-IR and GAD65...... autoantibodies, were used for sub-grouping patients by K-means clustering and for adjusting. Probability of diabetes complications (95% confidence interval), were calculated using logistic regression. RESULTS: Based on baseline data from patients with type 2 diabetes (n=2,290), the cluster analysis suggested up....... CONCLUSIONS: Patients with type 2 diabetes cluster into clinically relevant sub-groups based on routine clinical markers. The prevalence of diabetes complications seems to be sub-group specific. Our data suggests the need for a tailored strategy for the treatment of type 2 diabetes....

  9. Circulating tumor cell isolation and diagnostics: toward routine clinical use

    NARCIS (Netherlands)

    Stolpe, van de A.; Pantel, K.; Sleijfer, S.; Terstappen, L.W.; Toonder, den J.M.J.

    2011-01-01

    From February 7–11, 2011, the multidisciplinary Lorentz Workshop Circulating Tumor Cell (CTC) Isolation and Diagnostics: Toward Routine Clinical Use was held in Leiden (The Netherlands) to discuss progress and define challenges and potential solutions for development of clinically useful circulating

  10. Electrically detected displacement assay (EDDA): a practical approach to nucleic acid testing in clinical or medical diagnosis.

    Science.gov (United States)

    Liepold, P; Kratzmüller, T; Persike, N; Bandilla, M; Hinz, M; Wieder, H; Hillebrandt, H; Ferrer, E; Hartwich, G

    2008-07-01

    This paper introduces the electrically detected displacement assay (EDDA), a electrical biosensor detection principle for applications in medical and clinical diagnosis, and compares the method to currently available microarray technologies in this field. The sensor can be integrated into automated systems of routine diagnosis, but may also be used as a sensor that is directly applied to the polymerase chain reaction (PCR) reaction vessel to detect unlabeled target amplicons within a few minutes. Major aspects of sensor assembly like immobilization procedure, accessibility of the capture probes, and prevention from nonspecific target adsorption, that are a prerequisite for a robust and reliable performance of the sensor, are demonstrated. Additionally, exemplary results from a human papillomavirus assay are presented.

  11. Clinical Outcome of Degenerative Mitral Regurgitation: Critical Importance of Echocardiographic Quantitative Assessment in Routine Practice.

    Science.gov (United States)

    Antoine, Clemence; Benfari, Giovanni; Michelena, Hector I; Malouf, Joseph F; Nkomo, Vuyisile T; Thapa, Prabin; Enriquez-Sarano, Maurice

    2018-05-31

    Background -Echocardiographic quantitation of degenerative mitral regurgitation (DMR) is recommended whenever possible in clinical guidelines but is criticized and its scalability to routine clinical practice doubted. We hypothesized that echocardiographic DMR quantitation, performed in routine clinical practice by multiple practitioners predicts independently long-term survival, and thus is essential to DMR management. Methods -We included patients diagnosed with isolated mitral-valve-prolapse 2003-2011 and any degree of MR quantified by any physician/sonographer in routine clinical practice. Clinical/echocardiographic data acquired at diagnosis were retrieved electronically. Endpoint was mortality under medical treatment analyzed by Kaplan-Meir method and Proportional-Hazard models. Results -The cohort included 3914 patients (55% male) aged 62±17 years, with left ventricular ejection fraction (LVEF) 63±8% and routinely measured effective regurgitant orifice area (EROA) 19[0-40] mm 2 During follow-up (6.7±3.1 years) 696 patients died under medical management and 1263 underwent mitral surgery. In multivariate analysis, routinely measured EROA was associated with mortality (adjusted-hazard-ratio 1.19[1.13-1.24] p 40 mm 2 threshold. Conclusions -Echocardiographic DMR quantitation is scalable to routine practice and is independently associated with clinical outcome. Routinely measured EROA is strongly associated with long-term survival under medical treatment. Excess mortality vs. the general population appears in the "moderate" DMR range and steadily increases with higher EROA. Hence, individual EROA values should be integrated into therapeutic considerations, additionally to categorical DMR grading.

  12. A high resolution melting (HRM) technology-based assay for cost-efficient clinical detection and genotyping of herpes simplex virus (HSV)-1 and HSV-2.

    Science.gov (United States)

    Lieveld, M; Carregosa, A; Benoy, I; Redzic, N; Berth, M; Vanden Broeck, D

    2017-10-01

    Genital herpes can be caused by two very similar viruses, herpes simplex virus (HSV)-1 or HSV-2. These two HSV types cannot be distinguished clinically, but genotyping is recommended in the first-episodes of genital herpes to guide counselling and management. Quantitative polymerase chain reaction (qPCR) is the preferred diagnostic method for HSV typing. However, commercial qPCR methods use expensive fluorescent labeled probes for detection. Furthermore, most low-cost methods are not able to differentiate between HSV-1 and -2. The aim of this study was to develop a high resolution melting (HRM) technology-based assay for sensitive HSV-1 and HSV-2 detection and genotyping. Using a panel of 46 clinical specimens, the performance of the HRM assay was compared to two commercial HSV tests: the HRM assay detected HSV in all 23 positive samples, with no false positive results (100% concordance with HSV I/II Real-TM assay). Additionally, the HRM assay correctly genotyped both HSV types in a subset of these clinical samples, as determined by the Realstar HSV PCR Kit. The HSV HRM assay provides a cost-effective alternative method to conventional more expensive assays and can be used in routine clinical specimens, in cases where it is particularly necessary to detect and distinguish HSV-1 from -2. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  14. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  15. How characteristic routines of clinical departments influence students' self-regulated learning : A grounded theory study

    NARCIS (Netherlands)

    Berkhout, J J; Slootweg, I. A.; Helmich, Esther; Teunissen, P W; van der Vleuten, C. P. M.; Jaarsma, A. D. C.

    2017-01-01

    Background: In clerkships, students are expected to self-regulate their learning. How clinical departments and their routine approach on clerkships influences students' self-regulated learning (SRL) is unknown.Aim: This study explores how characteristic routines of clinical departments influence

  16. A new generation of cancer genome diagnostics for routine clinical use: overcoming the roadblocks to personalized cancer medicine.

    Science.gov (United States)

    Heuckmann, J M; Thomas, R K

    2015-09-01

    The identification of 'druggable' kinase gene alterations has revolutionized cancer treatment in the last decade by providing new and successfully targetable drug targets. Thus, genotyping tumors for matching the right patients with the right drugs have become a clinical routine. Today, advances in sequencing technology and computational genome analyses enable the discovery of a constantly growing number of genome alterations relevant for clinical decision making. As a consequence, several technological approaches have emerged in order to deal with these rapidly increasing demands for clinical cancer genome analyses. Here, we describe challenges on the path to the broad introduction of diagnostic cancer genome analyses and the technologies that can be applied to overcome them. We define three generations of molecular diagnostics that are in clinical use. The latest generation of these approaches involves deep and thus, highly sensitive sequencing of all therapeutically relevant types of genome alterations-mutations, copy number alterations and rearrangements/fusions-in a single assay. Such approaches therefore have substantial advantages (less time and less tissue required) over PCR-based methods that typically have to be combined with fluorescence in situ hybridization for detection of gene amplifications and fusions. Since these new technologies work reliably on routine diagnostic formalin-fixed, paraffin-embedded specimens, they can help expedite the broad introduction of personalized cancer therapy into the clinic by providing comprehensive, sensitive and accurate cancer genome diagnoses in 'real-time'. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Adiponectin as a routine clinical biomarker.

    Science.gov (United States)

    Kishida, Ken; Funahashi, Tohru; Shimomura, Iichiro

    2014-01-01

    Adiponectin is a protein synthesized and secreted predominantly by adipocytes into the peripheral blood. However, circulating adiponectin level is inversely related with body weight, especially visceral fat accumulation. The mechanism of this paradoxical relation remains obscure. Low circulating adiponectin concentrations (hypoadiponectinemia; osteoporosis, and cancer (endometrial cancer, postmenopausal breast cancer, leukemia, colon cancer, gastric cancer, prostate cancer). On the other hand, hyperadiponectinemia is associated with cardiac, renal and pulmonary diseases. This review article focuses on the significance of adiponectin as a clinical biomarker of obesity-related diseases. Routine measurement of adiponectin in patients with lifestyle-related diseases is highly recommended. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Overview of procalcitonin assays and procalcitonin-guided protocols for the management of patients with infections and sepsis.

    Science.gov (United States)

    Schuetz, Philipp; Bretscher, Celine; Bernasconi, Luca; Mueller, Beat

    2017-06-01

    Procalcitonin is a surrogate infection blood marker whose levels help estimate the likelihood of bacterial infections and correlate with their resolution. Recent trials have revealed the benefits of inclusion of procalcitonin in antibiotic stewardship protocols for initiation and discontinuation of antimicrobial therapy. Areas covered: Procalcitonin-guided antibiotic stewardship protocols have shown appreciable reductions in antibiotic use and duration of therapy in respiratory infections, sepsis, and other infections, with positive effects on clinical outcomes. Multiple fully automated and sensitive procalcitonin assays are routinely used in clinical practice. Utilization of these assays requires consideration of the clinical setting and knowledge of assay characteristics, particularly assay sensitivities, reproducibility, and performance across routinely used cut-off ranges. The authors provide an overview of the strengths and limitations of currently available procalcitonin assays and antibiotic therapy algorithms incorporating procalcitonin currently used in different clinical settings and in patients with different underlying infections. Expert commentary: Use of sensitive procalcitonin measurements in clinical algorithms can reduce antimicrobial overuse, decreasing the risk of side effects and controlling emerging bacterial multi-resistance. Before use in clinical practice, it is important to carefully assess the quality of novel PCT assays and rigorously evaluate them in target patient populations across clinically relevant cut-off ranges.

  19. Clinical relevance of routinely measured vital signs in hospitalized patients: a systematic review

    NARCIS (Netherlands)

    Storm-Versloot, Marja N.; Verweij, Lotte; Lucas, Cees; Ludikhuize, Jeroen; Goslings, J. Carel; Legemate, Dink A.; Vermeulen, Hester

    2014-01-01

    Conflicting evidence exists on the effectiveness of routinely measured vital signs on the early detection of increased probability of adverse events. To assess the clinical relevance of routinely measured vital signs in medically and surgically hospitalized patients through a systematic review.

  20. Performance Evaluation of an Automated ELISA System for Alzheimer's Disease Detection in Clinical Routine.

    Science.gov (United States)

    Chiasserini, Davide; Biscetti, Leonardo; Farotti, Lucia; Eusebi, Paolo; Salvadori, Nicola; Lisetti, Viviana; Baschieri, Francesca; Chipi, Elena; Frattini, Giulia; Stoops, Erik; Vanderstichele, Hugo; Calabresi, Paolo; Parnetti, Lucilla

    2016-07-22

    The variability of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers undermines their full-fledged introduction into routine diagnostics and clinical trials. Automation may help to increase precision and decrease operator errors, eventually improving the diagnostic performance. Here we evaluated three new CSF immunoassays, EUROIMMUNtrademark amyloid-β 1-40 (Aβ1-40), amyloid-β 1-42 (Aβ1-42), and total tau (t-tau), in combination with automated analysis of the samples. The CSF biomarkers were measured in a cohort consisting of AD patients (n = 28), mild cognitive impairment (MCI, n = 77), and neurological controls (OND, n = 35). MCI patients were evaluated yearly and cognitive functions were assessed by Mini-Mental State Examination. The patients clinically diagnosed with AD and MCI were classified according to the CSF biomarkers profile following NIA-AA criteria and the Erlangen score. Technical evaluation of the immunoassays was performed together with the calculation of their diagnostic performance. Furthermore, the results for EUROIMMUN Aβ1-42 and t-tau were compared to standard immunoassay methods (INNOTESTtrademark). EUROIMMUN assays for Aβ1-42 and t-tau correlated with INNOTEST (r = 0.83, p ratio measured with EUROIMMUN was the best parameter for AD detection and improved the diagnostic accuracy of Aβ1-42 (area under the curve = 0.93). In MCI patients, the Aβ1-42/Aβ1-40 ratio was associated with cognitive decline and clinical progression to AD.The diagnostic performance of the EUROIMMUN assays with automation is comparable to other currently used methods. The variability of the method and the value of the Aβ1-42/Aβ1-40 ratio in AD diagnosis need to be validated in large multi-center studies.

  1. How characteristic routines of clinical departments influence students' self-regulated learning: A grounded theory study.

    Science.gov (United States)

    Berkhout, J J; Slootweg, I A; Helmich, E; Teunissen, P W; van der Vleuten, C P M; Jaarsma, A D C

    2017-11-01

    In clerkships, students are expected to self-regulate their learning. How clinical departments and their routine approach on clerkships influences students' self-regulated learning (SRL) is unknown. This study explores how characteristic routines of clinical departments influence medical students' SRL. Six focus groups including 39 purposively sampled participants from one Dutch university were organized to study how characteristic routines of clinical departments influenced medical students' SRL from a constructivist paradigm, using grounded theory methodology. The focus groups were audio recorded, transcribed verbatim and were analyzed iteratively using constant comparison and open, axial and interpretive coding. Students described that clinical departments influenced their SRL through routines which affected the professional relationships they could engage in and affected their perception of a department's invested effort in them. Students' SRL in a clerkship can be supported by enabling them to engage others in their SRL and by having them feel that effort is invested in their learning. Our study gives a practical insight in how clinical departments influenced students' SRL. Clinical departments can affect students' motivation to engage in SRL, influence the variety of SRL strategies that students can use and how meaningful students perceive their SRL experiences to be.

  2. Advance Care Planning: Understanding Clinical Routines and Experiences of Interprofessional Team Members in Diverse Health Care Settings.

    Science.gov (United States)

    Arnett, Kelly; Sudore, Rebecca L; Nowels, David; Feng, Cindy X; Levy, Cari R; Lum, Hillary D

    2017-12-01

    Interprofessional health care team members consider advance care planning (ACP) to be important, yet gaps remain in systematic clinical routines to support ACP. A clearer understanding of the interprofessional team members' perspectives on ACP clinical routines in diverse settings is needed. One hundred eighteen health care team members from community-based clinics, long-term care facilities, academic clinics, federally qualified health centers, and hospitals participated in a 35-question, cross-sectional online survey to assess clinical routines, workflow processes, and policies relating to ACP. Respondents were 53% physicians, 18% advanced practice nurses, 11% nurses, and 18% other interprofessional team members including administrators, chaplains, social workers, and others. Regarding clinical routines, respondents reported that several interprofessional team members play a role in facilitating ACP (ie, physician, social worker, nurse, others). Most (62%) settings did not have, or did not know of, policies related to ACP documentation. Only 14% of settings had a patient education program. Two-thirds of the respondents said that addressing ACP is a high priority and 85% felt that nonphysicians could have ACP conversations with appropriate training. The clinical resources needed to improve clinical routines included training for providers and staff, dedicated staff to facilitate ACP, and availability of patient/family educational materials. Although interprofessional health care team members consider ACP a priority and several team members may be involved, clinical settings lack systematic clinical routines to support ACP. Patient educational materials, interprofessional team training, and policies to support ACP clinical workflows that do not rely solely on physicians could improve ACP across diverse clinical settings.

  3. Routine clinical application of virtual reality in abdominal surgery.

    Science.gov (United States)

    Sampogna, Gianluca; Pugliese, Raffaele; Elli, Marco; Vanzulli, Angelo; Forgione, Antonello

    2017-06-01

    The advantages of 3D reconstruction, immersive virtual reality (VR) and 3D printing in abdominal surgery have been enunciated for many years, but still today their application in routine clinical practice is almost nil. We investigate their feasibility, user appreciation and clinical impact. Fifteen patients undergoing pancreatic, hepatic or renal surgery were studied realizing a 3D reconstruction of target anatomy. Then, an immersive VR environment was developed to import 3D models, and some details of the 3D scene were printed. All the phases of our workflow employed open-source software and low-cost hardware, easily implementable by other surgical services. A qualitative evaluation of the three approaches was performed by 20 surgeons, who filled in a specific questionnaire regarding a clinical case for each organ considered. Preoperative surgical planning and intraoperative guidance was feasible for all patients included in the study. The vast majority of surgeons interviewed scored their quality and usefulness as very good. Despite extra time, costs and efforts necessary to implement these systems, the benefits shown by the analysis of questionnaires recommend to invest more resources to train physicians to adopt these technologies routinely, even if further and larger studies are still mandatory.

  4. A new generation videokymography for routine clinical vocal fold examination

    NARCIS (Netherlands)

    Qiu, Qingjun; Schutte, Harm K.

    2006-01-01

    Objective. This study aims to introduce a new-generation videokymographic system, which provides simultaneous laryngoscopic and kymographic image, for routine clinical vocal fold examination. Study Design: The authors explored a new imaging method for diagnosis and evaluation of voice disorders.

  5. Radiographic demonstration of small intestinal villi on routine clinical studies

    International Nuclear Information System (INIS)

    Gelfand, D.W.; Ott, D.J.

    1981-01-01

    The radiographic demonstration of the small intestinal villi is reported. The villi were demonstrable with both single- and double-contrast methods on routine clinical studies. The primary requirement for their delineation appears to be employment of a high-resolution radiographic system. (orig.) [de

  6. Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

    Science.gov (United States)

    Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2016-11-01

    The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.

  7. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    Science.gov (United States)

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  8. Experience of domestic violence routine screening in Family Planning NSW clinics.

    Science.gov (United States)

    Hunter, Tara; Botfield, Jessica R; Estoesta, Jane; Markham, Pippa; Robertson, Sarah; McGeechan, Kevin

    2017-04-01

    This study reviewed implementation of the Domestic Violence Routine Screening (DVRS) program at Family Planning NSW and outcomes of screening to determine the feasibility of routine screening in a family planning setting and the suitability of this program in the context of women's reproductive and sexual health. A retrospective review of medical records was undertaken of eligible women attending Family Planning NSW clinics between 1 January and 31 December 2015. Modified Poisson regression was used to estimate prevalence ratios and assess association between binary outcomes and client characteristics. Of 13440 eligible women, 5491 were screened (41%). Number of visits, clinic attended, age, employment status and disability were associated with completion of screening. In all, 220 women (4.0%) disclosed domestic violence. Factors associated with disclosure were clinic attended, age group, region of birth, employment status, education and disability. Women who disclosed domestic violence were more likely to have discussed issues related to sexually transmissible infections in their consultation. All women who disclosed were assessed for any safety concerns and offered a range of suitable referral options. Although routine screening may not be appropriate in all health settings, given associations between domestic violence and sexual and reproductive health, a DVRS program is considered appropriate in sexual and reproductive health clinics and appears to be feasible in a service such as Family Planning NSW. Consistent implementation of the program should continue at Family Planning NSW and be expanded to other family planning services in Australia to support identification and early intervention for women affected by domestic violence.

  9. The microculture-kinetic (MiCK) assay: the role of a drug-induced apoptosis assay in drug development and clinical care.

    Science.gov (United States)

    Bosserman, Linda; Prendergast, Franklyn; Herbst, Roy; Fleisher, Martin; Salom, Emery; Strickland, Steven; Raptis, Anastasios; Hallquist, Allan; Perree, Mathieu; Rajurkar, Swapnil; Karimi, Misagh; Rogers, Karl; Davidson, Dirk; Willis, Carl; Penalver, Manuel; Homesley, Howard; Burrell, Matthew; Garrett, Audrey; Rutledge, James; Chernick, Michael; Presant, Cary A

    2012-08-15

    A drug-induced apoptosis assay, termed the microculture-kinetic (MiCK) assay, has been developed. Blinded clinical trials have shown higher response rates and longer survival in groups of patients with acute myelocytic leukemia and epithelial ovarian cancer who have been treated with drugs that show high apoptosis in the MiCK assay. Unblinded clinical trials in multiple tumor types have shown that the assay will be used frequently by clinicians to determine treatment, and when used, results in higher response rates, longer times to relapse, and longer survivals. Model economic analyses suggest possible cost savings in clinical use based on increased generic drug use and single-agent substitution for combination therapies. Two initial studies with drugs in development are promising. The assay may help reduce costs and speed time to drug approval. Correlative studies with molecular biomarkers are planned. This assay may have a role both in personalized clinical therapy and in more efficient drug development. ©2012 AACR.

  10. Medical Devices; Immunology and Microbiology Devices; Classification of the Assayed Quality Control Material for Clinical Microbiology Assays. Final order.

    Science.gov (United States)

    2017-07-27

    The Food and Drug Administration (FDA, Agency, or we) is classifying the assayed quality control material for clinical microbiology assays into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the assayed quality control material for clinical microbiology assays' classification. The Agency is classifying the device into class II (special controls) to provide a reasonable assurance of safety and effectiveness of the device.

  11. Diagnosis of antiphospholipid syndrome in routine clinical practice

    Science.gov (United States)

    Hills, J; Machin, SJ; Cohen, H

    2013-01-01

    The updated international consensus criteria for definite antiphospholipid syndrome (APS) are useful for scientific clinical studies. However, there remains a need for diagnostic criteria for routine clinical use. We audited the results of routine antiphospholipid antibodies (aPLs) in a cohort of 193 consecutive patients with aPL positivity-based testing for lupus anticoagulant (LA), IgG and IgM anticardiolipin (aCL) and anti-ß2glycoprotein-1 antibodies (aß2GPI). Medium/high-titre aCL/aβ2GPI was defined as >99th percentile. Low-titre aCL/aβ2GPI positivity (>95th < 99th percentile) was considered positive for obstetric but not for thrombotic APS. One hundred of the 145 patients fulfilled both clinical and laboratory criteria for definite APS. Twenty-six women with purely obstetric APS had persistent low-titre aCL and/or aβ2GPI. With the inclusion of these patients, 126 of the 145 patients were considered to have APS. Sixty-seven out of 126 patients were LA-negative, of whom 12 had aCL only, 37 had aβ2GPI only and 18 positive were for both. The omission of aCL or aβ2GPI testing from investigation of APS would have led to a failure to diagnose APS in 9.5% and 29.4% of patients, respectively. Our data suggest that LA, aCL and aβ2GPI testing are all required for the accurate diagnosis of APS and that low-titre antibodies should be included in the diagnosis of obstetric APS. PMID:22988029

  12. First two-reagent vitamin D assay for general clinical chemistry.

    Science.gov (United States)

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Optical assay for biotechnology and clinical diagnosis.

    Science.gov (United States)

    Moczko, Ewa; Cauchi, Michael; Turner, Claire; Meglinski, Igor; Piletsky, Sergey

    2011-08-01

    In this paper, we present an optical diagnostic assay consisting of a mixture of environmental-sensitive fluorescent dyes combined with multivariate data analysis for quantitative and qualitative examination of biological and clinical samples. The performance of the assay is based on the analysis of spectrum of the selected fluorescent dyes with the operational principle similar to electronic nose and electronic tongue systems. This approach has been successfully applied for monitoring of growing cell cultures and identification of gastrointestinal diseases in humans.

  14. The effectiveness of online cognitive behavioral treatment in routine clinical practice

    NARCIS (Netherlands)

    Ruwaard, Jeroen; Lange, Alfred; Schrieken, Bart; Dolan, Conor V; Emmelkamp, Paul

    2012-01-01

    CONTEXT: Randomized controlled trails have identified online cognitive behavioral therapy as an efficacious intervention in the management of common mental health disorders. OBJECTIVE: To assess the effectiveness of online CBT for different mental disorders in routine clinical practice. DESIGN: An

  15. The effectiveness of online cognitive behavioral treatment in routine clinical practice

    NARCIS (Netherlands)

    Ruwaard, J.; Lange, A.; Schrieken, B.; Dolan, C.V.; Emmelkamp, P.

    2012-01-01

    Context Randomized controlled trails have identified online cognitive behavioral therapy as an efficacious intervention in the management of common mental health disorders. Objective To assess the effectiveness of online CBT for different mental disorders in routine clinical practice. Design An

  16. Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.

    Science.gov (United States)

    Groome, N P

    1981-10-01

    The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.

  17. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    Science.gov (United States)

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  18. The prevalence of adrenal incidentaloma in routine clinical practice.

    LENUS (Irish Health Repository)

    Davenport, Colin

    2012-02-01

    The prevalence of adrenal incidentaloma (AI) on computed tomography (CT) in the general population has been reported to be as high as 4.2%. However, many of the previous studies in this field utilised a prospective approach with analysis of CT scans performed by one or more radiologists with a specialist interest in adrenal tumours and a specific focus on identifying the presence of an adrenal mass. A typical radiology department, with a focus on the patient\\'s presenting complaint as opposed to the adrenal gland, may not be expected to diagnose as many adrenal incidentalomas as would be identified in a dedicated research protocol. We hypothesised that the number of AI reported in routine clinical practice is significantly lower than the published figures would suggest. We retrospectively reviewed the reports of all CT thorax and abdomen scans performed in our hospital over a 2 year period. 3,099 patients underwent imaging, with 3,705 scans performed. The median age was 63 years (range 18-98). Thirty-seven true AI were diagnosed during the time period studied. Twenty-two were diagnosed by CT abdomen (22\\/2,227) and 12 by CT thorax (12\\/1,478), a prevalence of 0.98 and 0.81% with CT abdomen and thorax, respectively, for AI in routine clinical practice.

  19. SPIRIT: Systematic Planning of Intelligent Reuse of Integrated Clinical Routine Data. A Conceptual Best-practice Framework and Procedure Model.

    Science.gov (United States)

    Hackl, W O; Ammenwerth, E

    2016-01-01

    Secondary use of clinical routine data is receiving an increasing amount of attention in biomedicine and healthcare. However, building and analysing integrated clinical routine data repositories are nontrivial, challenging tasks. As in most evolving fields, recognized standards, well-proven methodological frameworks, or accurately described best-practice approaches for the systematic planning of solutions for secondary use of routine medical record data are missing. We propose a conceptual best-practice framework and procedure model for the systematic planning of intelligent reuse of integrated clinical routine data (SPIRIT). SPIRIT was developed based on a broad literature overview and further refined in two case studies with different kinds of clinical routine data, including process-oriented nursing data from a large hospital group and high-volume multimodal clinical data from a neurologic intensive care unit. SPIRIT aims at tailoring secondary use solutions to specific needs of single departments without losing sight of the institution as a whole. It provides a general conceptual best-practice framework consisting of three parts: First, a secondary use strategy for the whole organization is determined. Second, comprehensive analyses are conducted from two different viewpoints to define the requirements regarding a clinical routine data reuse solution at the system level from the data perspective (BOTTOM UP) and at the strategic level from the future users perspective (TOP DOWN). An obligatory clinical context analysis (IN BETWEEN) facilitates refinement, combination, and integration of the different requirements. The third part of SPIRIT is dedicated to implementation, which comprises design and realization of clinical data integration and management as well as data analysis solutions. The SPIRIT framework is intended to be used to systematically plan the intelligent reuse of clinical routine data for multiple purposes, which often was not intended when the

  20. The influence of ketoacids on plasma creatinine assays in diabetic ketoacidosis

    NARCIS (Netherlands)

    Kemperman, F. A.; Weber, J. A.; Gorgels, J.; van Zanten, A. P.; Krediet, R. T.; Arisz, L.

    2000-01-01

    OBJECTIVE: Analysis of the interference of ketoacids on various routine plasma creatinine assays during a clinical episode of diabetic ketoacidosis (DKA). DESIGN: Observational study. Blood samples were drawn before, during and after standard in-hospital treatment. Plasma creatinine was measured

  1. Yeast identification in routine clinical microbiology laboratory and its clinical relevance

    Directory of Open Access Journals (Sweden)

    S Agarwal

    2011-01-01

    Full Text Available Rapid identification of yeast infections is helpful in prompt appropriate antifungal therapy. In the present study, the usefulness of chromogenic medium, slide culture technique and Vitek2 Compact (V2C has been analysed. A total of 173 clinical isolates of yeast species were included in the study. An algorithm to identify such isolates in routine clinical microbiology laboratory was prepared and followed. Chromogenic medium was able to identify Candida albicans, C. tropicalis, C. krusei, C. parapsilosis and Trichosporon asahii. Chromogenic medium was also helpful in identifying "multi-species" yeast infections. The medium was unable to provide presumptive identification of C. pelliculosa, C. utilis, C. rugosa, C. glabrata and C. hemulonii. Vitek 2 compact (V2C differentiated all pseudohypae non-producing yeast species. The algorithm followed was helpful in timely presumptive identification and final diagnosis of yeast infections, including multi-species yeast infections.

  2. IT Infrastructure to Support the Secondary Use of Routinely Acquired Clinical Imaging Data for Research

    NARCIS (Netherlands)

    K.Y.E. Leung (Esther); F. van der Lijn (Fedde); H.A. Vrooman (Henri); M.C.J.M. Sturkenboom (Miriam); W.J. Niessen (Wiro)

    2014-01-01

    textabstractWe propose an infrastructure for the automated anonymization, extraction and processing of image data stored in clinical data repositories to make routinely acquired imaging data available for research purposes. The automated system, which was tested in the context of analyzing routinely

  3. The quality of clinical maternal and neonatal healthcare - a strategy for identifying 'routine care signal functions'.

    Directory of Open Access Journals (Sweden)

    Stephan Brenner

    Full Text Available A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs, a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC, the 'EmOC signal functions', a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example.We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi.Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants' adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks.The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining

  4. The quality of clinical maternal and neonatal healthcare - a strategy for identifying 'routine care signal functions'.

    Science.gov (United States)

    Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S

    2015-01-01

    A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the 'EmOC signal functions', a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants' adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program

  5. The prevalence of adrenal incidentaloma in routine clinical practice.

    LENUS (Irish Health Repository)

    Davenport, Colin

    2011-03-10

    The prevalence of adrenal incidentaloma (AI) on computed tomography (CT) in the general population has been reported to be as high as 4.2%. However, many of the previous studies in this field utilised a prospective approach with analysis of CT scans performed by one or more radiologists with a specialist interest in adrenal tumours and a specific focus on identifying the presence of an adrenal mass. A typical radiology department, with a focus on the patient\\'s presenting complaint as opposed to the adrenal gland, may not be expected to diagnose as many adrenal incidentalomas as would be identified in a dedicated research protocol. We hypothesised that the number of AI reported in routine clinical practice is significantly lower than the published figures would suggest. We retrospectively reviewed the reports of all CT thorax and abdomen scans performed in our hospital over a 2 year period. 3,099 patients underwent imaging, with 3,705 scans performed. The median age was 63 years (range 18-98). Thirty-seven true AI were diagnosed during the time period studied. Twenty-two were diagnosed by CT abdomen (22\\/2,227) and 12 by CT thorax (12\\/1,478), a prevalence of 0.98 and 0.81% with CT abdomen and thorax, respectively, for AI in routine clinical practice.

  6. A Modified NK Cell Degranulation Assay Applicable for Routine Evaluation of NK Cell Function

    Directory of Open Access Journals (Sweden)

    Snehal Shabrish

    2016-01-01

    Full Text Available Natural killer (NK cells play important role in innate immunity against tumors and viral infections. Studies show that lysosome-associated membrane protein-1 (LAMP-1, CD107a is a marker for degranulation of NK and cytotoxic T cells and its expression is a sensitive marker for the cytotoxic activity determination. The conventional methods of determination of CD107a on NK cells involve use of peripheral blood mononuclear cells (PBMC or pure NK cells and K562 cells as stimulants. Thus, it requires large volume of blood sample which is usually difficult to obtain in pediatric patients and patients with cytopenia and also requires specialized laboratory for maintaining cell line. We have designed a flow cytometric assay to determine CD107a on NK cells using whole blood, eliminating the need for isolation of PBMC or isolate NK cells. This assay uses phorbol-12-myristate-13-acetate (PMA and calcium ionophore (Ca2+-ionophore instead of K562 cells for stimulation and thus does not require specialized cell culture laboratory. CD107a expression on NK cells using modified NK cell degranulation assay compared to the conventional assay was significantly elevated (p<0.0001. It was also validated by testing patients diagnosed with familial hemophagocytic lymphohistiocytosis (FHL with defect in exocytosis. This assay is rapid, cost effective, and reproducible and requires significantly less volume of blood which is important for clinical evaluation of NK cells.

  7. Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration

    NARCIS (Netherlands)

    Heijboer, Annemieke C.; Blankenstein, Marinus A.; Kema, Ido P.; Buijs, Madelon M.

    2012-01-01

    Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available.

  8. Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration

    NARCIS (Netherlands)

    Heijboer, A.C.; Blankenstein, M.A.; Kema, I.P.; Buijs, M.M.

    2012-01-01

    BACKGROUND: Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now

  9. Frequency of vaginal candidiasis in pregnant women attending routine antenatal clinic

    International Nuclear Information System (INIS)

    Parveen, N.; Munir, A.A.; Majeed, R.

    2008-01-01

    To determine the frequency of vaginal candidiasis in clinically symptomatic and asymptomatic cases of pregnant women attending routine antenatal clinic. A total of 110 pregnant women were nonrandomly recruited by convenient sampling. The studied variables included the demographic data information on parity, trimester of pregnancy, presence of vaginal discharge and the presence or absence of diabetes. Vulva and vagina were inspected for signs of inflammation and discharge with sterile speculum and vaginal specimens were collected with sterile cotton tipped swabs. Swabs were subjected to Gram staining and examined microscopically for the diagnosis of candidiasis. The frequency of vaginal candidiasis during pregnancy was found to be 38%, in which 27% were symptomatic and 11% were asymptomatic group. Increased ratio of infection was observed in multigravida and diabetic women. There was no marked differences in results with respect to age and trimester of pregnancy. Although there is generally a high frequency of vaginal candidiasis, an increased ratio of vaginal candidiasis in multigravida and diabetic pregnant women requires these women to be routinely screened for vaginal candidiasis regardless of symptomatic status. (author)

  10. An LC-MS Assay with Isocratic Separation and On-Line Solid Phase Extraction to Improve the Routine Therapeutic Drug Monitoring of Busulfan in Plasma

    Directory of Open Access Journals (Sweden)

    Ialongo Cristiano

    2017-04-01

    Full Text Available Background: Busulfan (Bu requires therapeutic drug monitoring (TDM in subjects undergoing a conditioning regimen for hematopoietic stem cell transplantation (HSCT. To speed up the procedure and increase reproducibility, we improved our routine LC-MS/MS assay using the on-line solid-phase extraction (SPE of samples.

  11. Fission reactor based epithermal neutron irradiation facilities for routine clinical application in BNCT-Hatanaka memorial lecture

    International Nuclear Information System (INIS)

    Harling, Otto K.

    2009-01-01

    Based on experience gained in the recent clinical studies at MIT/Harvard, the desirable characteristics of epithermal neutron irradiation facilities for eventual routine clinical BNCT are suggested. A discussion of two approaches to using fission reactors for epithermal neutron BNCT is provided. This is followed by specific suggestions for the performance and features needed for high throughput clinical BNCT. An example of a current state-of-the-art, reactor based facility, suited for routine clinical use is discussed. Some comments are provided on the current status of reactor versus accelerator based epithermal neutron sources for BNCT. This paper concludes with a summary and a few personal observations on BNCT by the author.

  12. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  13. Routine operation of an Elliott 903 computer in a clinical chemistry laboratory

    Science.gov (United States)

    Whitby, L. G.; Simpson, D.

    1973-01-01

    Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided. PMID:4580240

  14. Validation of a next-generation sequencing assay for clinical molecular oncology.

    Science.gov (United States)

    Cottrell, Catherine E; Al-Kateb, Hussam; Bredemeyer, Andrew J; Duncavage, Eric J; Spencer, David H; Abel, Haley J; Lockwood, Christina M; Hagemann, Ian S; O'Guin, Stephanie M; Burcea, Lauren C; Sawyer, Christopher S; Oschwald, Dayna M; Stratman, Jennifer L; Sher, Dorie A; Johnson, Mark R; Brown, Justin T; Cliften, Paul F; George, Bijoy; McIntosh, Leslie D; Shrivastava, Savita; Nguyen, Tudung T; Payton, Jacqueline E; Watson, Mark A; Crosby, Seth D; Head, Richard D; Mitra, Robi D; Nagarajan, Rakesh; Kulkarni, Shashikant; Seibert, Karen; Virgin, Herbert W; Milbrandt, Jeffrey; Pfeifer, John D

    2014-01-01

    Currently, oncology testing includes molecular studies and cytogenetic analysis to detect genetic aberrations of clinical significance. Next-generation sequencing (NGS) allows rapid analysis of multiple genes for clinically actionable somatic variants. The WUCaMP assay uses targeted capture for NGS analysis of 25 cancer-associated genes to detect mutations at actionable loci. We present clinical validation of the assay and a detailed framework for design and validation of similar clinical assays. Deep sequencing of 78 tumor specimens (≥ 1000× average unique coverage across the capture region) achieved high sensitivity for detecting somatic variants at low allele fraction (AF). Validation revealed sensitivities and specificities of 100% for detection of single-nucleotide variants (SNVs) within coding regions, compared with SNP array sequence data (95% CI = 83.4-100.0 for sensitivity and 94.2-100.0 for specificity) or whole-genome sequencing (95% CI = 89.1-100.0 for sensitivity and 99.9-100.0 for specificity) of HapMap samples. Sensitivity for detecting variants at an observed 10% AF was 100% (95% CI = 93.2-100.0) in HapMap mixes. Analysis of 15 masked specimens harboring clinically reported variants yielded concordant calls for 13/13 variants at AF of ≥ 15%. The WUCaMP assay is a robust and sensitive method to detect somatic variants of clinical significance in molecular oncology laboratories, with reduced time and cost of genetic analysis allowing for strategic patient management. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  15. Rapid targeted somatic mutation analysis of solid tumors in routine clinical diagnostics.

    Science.gov (United States)

    Magliacane, Gilda; Grassini, Greta; Bartocci, Paola; Francaviglia, Ilaria; Dal Cin, Elena; Barbieri, Gianluca; Arrigoni, Gianluigi; Pecciarini, Lorenza; Doglioni, Claudio; Cangi, Maria Giulia

    2015-10-13

    Tumor genotyping is an essential step in routine clinical practice and pathology laboratories face a major challenge in being able to provide rapid, sensitive and updated molecular tests. We developed a novel mass spectrometry multiplexed genotyping platform named PentaPanel to concurrently assess single nucleotide polymorphisms in 56 hotspots of the 5 most clinically relevant cancer genes, KRAS, NRAS, BRAF, EGFR and PIK3CA for a total of 221 detectable mutations. To both evaluate and validate the PentaPanel performance, we investigated 1025 tumor specimens of 6 different cancer types (carcinomas of colon, lung, breast, pancreas, and biliary tract, and melanomas), systematically addressing sensitivity, specificity, and reproducibility of our platform. Sanger sequencing was also performed for all the study samples. Our data showed that PentaPanel is a high throughput and robust tool, allowing genotyping for targeted therapy selection of 10 patients in the same run, with a practical turnaround time of 2 working days. Importantly, it was successfully used to interrogate different DNAs isolated from routinely processed specimens (formalin-fixed paraffin embedded, frozen, and cytological samples), covering all the requirements of clinical tests. In conclusion, the PentaPanel platform can provide an immediate, accurate and cost effective multiplex approach for clinically relevant gene mutation analysis in many solid tumors and its utility across many diseases can be particularly relevant in multiple clinical trials, including the new basket trial approach, aiming to identify appropriate targeted drug combination strategies.

  16. New Insights into Butyrylcholinesterase Activity Assay: Serum Dilution Factor as a Crucial Parameter.

    Directory of Open Access Journals (Sweden)

    Joanna Jońca

    Full Text Available Butyrylcholinesterase (BChE activity assay and inhibitor phenotyping can help to identify patients at risk of prolonged paralysis following the administration of neuromuscular blocking agents. The assay plays an important role in clinical chemistry as a good diagnostic marker for intoxication with pesticides and nerve agents. Furthermore, the assay is also commonly used for in vitro characterization of cholinesterases, their toxins and drugs. There is still lack of standardized procedure for measurement of BChE activity and many laboratories use different substrates at various concentrations. The purpose of this study was to validate the BChE activity assay to determine the best dilution of human serum and the most optimal concentration of substrates and inhibitors. Serum BChE activity was measured using modified Ellman's method applicable for a microplate reader. We present our experience and new insights into the protocol for high-throughput routine assays of human plasma cholinesterase activities adapted to a microplate reader. During our routine assays used for the determination of BChE activity, we have observed that serum dilution factor influences the results obtained. We show that a 400-fold dilution of serum and 5mM S-butyrylthiocholine iodide can be successfully used for the accurate measurement of BChE activity in human serum. We also discuss usage of various concentrations of dibucaine and fluoride in BChE phenotyping. This study indicates that some factors of such a multicomponent clinical material like serum can influence kinetic parameters of the BChE. The observed inhibitory effect is dependent on serum dilution factor used in the assay.

  17. The Quality of Clinical Maternal and Neonatal Healthcare – A Strategy for Identifying ‘Routine Care Signal Functions’

    Science.gov (United States)

    Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S.

    2015-01-01

    Background A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the ‘EmOC signal functions’, a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. Methods We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Results Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants’ adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. Conclusion The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes

  18. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    Science.gov (United States)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  19. Can complex health interventions be evaluated using routine clinical and administrative data? - a realist evaluation approach.

    Science.gov (United States)

    Riippa, Iiris; Kahilakoski, Olli-Pekka; Linna, Miika; Hietala, Minni

    2014-12-01

    Interventions aimed at improving chronic care typically consist of multiple interconnected parts, all of which are essential to the effect of the intervention. Limited attention has been paid to the use of routine clinical and administrative data in the evolution of these complex interventions. The purpose of this study is to examine the feasibility of routinely collected data when evaluating complex interventions and to demonstrate how a theory-based, realist approach to evaluation may increase the feasibility of routine data. We present a case study of evaluating a complex intervention, namely, the chronic care model (CCM), in Finnish primary health care. Issues typically faced when evaluating the effects of a complex intervention on health outcomes and resource use are identified by using routine data in a natural setting, and we apply context-mechanism-outcome (CMO) approach from the realist evaluation paradigm to improve the feasibility of using routine data in evaluating complex interventions. From an experimentalist approach that dominates the medical literature, routine data collected from a single centre offered a poor starting point for evaluating complex interventions. However, the CMO approach offered tools for identifying indicators needed to evaluate complex interventions. Applying the CMO approach can aid in a typical evaluation setting encountered by primary care managers: one in which the intervention is complex, the primary data source is routinely collected clinical and administrative data from a single centre, and in which randomization of patients into two research arms is too resource consuming to arrange. © 2014 John Wiley & Sons, Ltd.

  20. Comparison of different references for brain perfusion SPECT quantification in clinical routine

    International Nuclear Information System (INIS)

    Olivera J, P.; Acton, P.; Costa, D.

    1997-01-01

    Full text: We used 40 brain perfusion SPECT studies from the INM, UCL database to investigate the performance of several references (denominators) in the calculation of perfusion ratios with single photon emission tomography (S PET) within a routine clinical service. According to clinical diagnosis and previous SPECT findings 4 groups were identified composed of: 10 controls (C, 23 to 84 y old); 10 myalgic-encephalomyelitis / chronic fatigue syndrome (ME/CFS, 22 to 61 y old); 10 major depression (MD, 24 to 68 y old); and 10 temporal lobe epilepsy (TLE, 19 to 39 y old). Routine protocols for processing were used and the analysis was blind to group classification. Brain perfusion ratios were calculated using 7 different references: hemi cerebellum with higher counts (Cer), total counts in a 4 pixel slice through the basal ganglia slice (BG), average counts per pixel in the visual cortex (VC), average counts per pixel in the white matter (WM), total acquired counts (TAC), total reconstructed counts (TRC) and maximum counts per pixel in the entire study (MAXX). Unpaired test to compare different diagnostic groups, coefficient of variation (CV) to assess the reliability to each references followed by ANOVA were the statistical test used. The lowest mean CV's were found with VC (4.8%) and TRC (5.1%), with all the others significantly higher (p<0.0001). The range of CV's for Cer was the lowest (3.7% to 5.9%). Consistent differentiation between diagnostic groups and controls was only obtained with Cer. In conclusion, it appears that for clinical routine services Cer is the most reliable reference, exception made for all diseases affecting the cerebellum. In these cases TRC or VC should be preferred. (authors)

  1. The clinical value of daily routine chest radiographs in a mixed medical-surgical intensive care unit is low.

    Science.gov (United States)

    Graat, Marleen E; Choi, Goda; Wolthuis, Esther K; Korevaar, Johanna C; Spronk, Peter E; Stoker, Jaap; Vroom, Margreeth B; Schultz, Marcus J

    2006-02-01

    The clinical value of daily routine chest radiographs (CXRs) in critically ill patients is unknown. We conducted this study to evaluate how frequently unexpected predefined major abnormalities are identified with daily routine CXRs, and how often these findings lead to a change in care for intensive care unit (ICU) patients. This was a prospective observational study conducted in a 28-bed, mixed medical-surgical ICU of a university hospital. Over a 5-month period, 2,457 daily routine CXRs were done in 754 consecutive ICU patients. The majority of these CXRs did not reveal any new predefined major finding. In only 5.8% of daily routine CXRs (14.3% of patients) was one or more new and unexpected abnormality encountered, including large atelectases (24 times in 20 patients), large infiltrates (23 in 22), severe pulmonary congestion (29 in 25), severe pleural effusion (13 in 13), pneumothorax/pneumomediastinum (14 in 13), and malposition of the orotracheal tube (32 in 26). Fewer than half of the CXRs with a new and unexpected finding were ultimately clinically relevant; in only 2.2% of all daily routine CXRs (6.4% of patients) did these radiologic abnormalities result in a change to therapy. Subgroup analysis revealed no differences between medical and surgical patients with regard to the incidence of new and unexpected findings on daily routine CXRs and the effect of new and unexpected CXR findings on daily care. In the ICU, daily routine CXRs seldom reveal unexpected, clinically relevant abnormalities, and they rarely prompt action. We propose that this diagnostic examination be abandoned in ICU patients.

  2. Implementation aspects of image management, archiving, and communication systems in routine clinical use

    NARCIS (Netherlands)

    Haar Romenij, ter B.M.

    1991-01-01

    Implementation of a digital imaging network in routine clinical use is a difficult task. Not only the high technical requirements, but especially the complexity of the organization of the diagnostic information flow in a hospital makes commitment essential in PACS implementation. The application of

  3. ELISPOT Assay for Monitoring Cytotoxic T Lymphocytes (CTL Activity in Cancer Vaccine Clinical Trials

    Directory of Open Access Journals (Sweden)

    Thomas J. Sayers

    2012-05-01

    Full Text Available The profiling and monitoring of immune responses are key elements in the evaluation of the efficacy and development of new biotherapies, and a number of assays have been introduced for analyzing various immune parameters before, during, and after immunotherapy. The choice of immune assays for a given clinical trial depends on the known or suggested immunomodulating mechanisms associated with the tested therapeutic modality. Cell-mediated cytotoxicity represents a key mechanism in the immune response to various pathogens and tumors. Therefore, the selection of monitoring methods for the appropriate assessment of cell-mediated cytotoxicity is thought to be crucial. Assays that can detect both cytotoxic T lymphocytes (CTL frequency and function, such as the IFN-γ enzyme-linked immunospot assay (ELISPOT have gained increasing popularity for monitoring clinical trials and in basic research. Results from various clinical trials, including peptide and whole tumor cell vaccination and cytokine treatment, have shown the suitability of the IFN-γ ELISPOT assay for monitoring T cell responses. However, the Granzyme B ELISPOT assay and Perforin ELISPOT assay may represent a more direct analysis of cell-mediated cytotoxicity as compared to the IFN-γ ELISPOT, since Granzyme B and perforin are the key mediators of target cell death via the granule-mediated pathway. In this review we analyze our own data and the data reported by others with regard to the application of various modifications of ELISPOT assays for monitoring CTL activity in clinical vaccine trials.

  4. Use of structured musculoskeletal examination routines in undergraduate medical education and postgraduate clinical practice - a UK survey.

    Science.gov (United States)

    Baker, Kenneth F; Jandial, Sharmila; Thompson, Ben; Walker, David; Taylor, Ken; Foster, Helen E

    2016-10-21

    Structured examination routines have been developed as educational resources for musculoskeletal clinical skills teaching, including Gait-Arms-Legs-Spine (GALS), Regional Examination of the Musculoskeletal System (REMS) and paediatric GALS (pGALS). In this study, we aimed to assess the awareness and use of these examination routines in undergraduate medical teaching in UK medical schools and UK postgraduate clinical practice. Electronic questionnaires were distributed to adult and paediatric musculoskeletal teaching leads at UK medical schools and current UK doctors in training. Responses were received from 67 tutors representing teaching at 22/33 [67 %] of all UK medical schools, and 70 trainee doctors across a range of postgraduate training specialities. There was widespread adoption, at responding medical schools, of the adult examination routines within musculoskeletal teaching (GALS: 14/16 [88 %]; REMS: 12/16 [75 %]) and assessment (GALS: 13/16 [81 %]; REMS: 12/16 [75 %]). More trainees were aware of GALS (64/70 [91 %]) than REMS (14/67 [21 %]). Of the 39 trainees who used GALS in their clinical practice, 35/39 [90 %] reported that it had improved their confidence in musculoskeletal examination. Of the 17/22 responding medical schools that included paediatric musculoskeletal examination within their curricula, 15/17 [88 %] used the pGALS approach and this was included within student assessment at 4 medical schools. We demonstrate the widespread adoption of these examination routines in undergraduate education and significant uptake in postgraduate clinical practice. Further study is required to understand their impact upon clinical performance.

  5. Performance Evaluation of the Elecsys Syphilis Assay for the Detection of Total Antibodies to Treponema pallidum

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona

    2014-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799

  6. Evaluation of the TEG® platelet mappingTM assay in blood donors

    DEFF Research Database (Denmark)

    Bochsen, Louise; Wiinberg, Bo; Kjelgaard-Hansen, Mads Jens

    2007-01-01

    for quantification of platelet function, including the contribution of the adenosine diphosphate (ADP) and thromboxane A2 (TxA2) receptors to clot formation. Methods In 43 healthy blood donors, the analytical (CVa) and inter-individual variability (CVg) of the TEG® Platelet MappingTM assay were determined together......Background Monitoring of antiplatelet therapy in patients at cardiovascular risk is difficult because existing platelet function tests are too sophisticated for clinical routine. The whole blood TEG® Platelet MappingTM assay measures clot strength as maximal amplitude (MA) and enables...

  7. Gamification of Clinical Routine: The Dr. Fill Approach.

    Science.gov (United States)

    Bukowski, Mark; Kühn, Martin; Zhao, Xiaoqing; Bettermann, Ralf; Jonas, Stephan

    2016-01-01

    Gamification is used in clinical context in the health care education. Furthermore, it has shown great promises to improve the performance of the health care staff in their daily routine. In this work we focus on the medication sorting task, which is performed manually in hospitals. This task is very error prone and needs to be performed daily. Nevertheless, errors in the medication are crucial and lead to serious complications. In this work we present a real world gamification approach of the medication sorting task in a patient's daily pill organizer. The player of the game needs to sort the correct medication into the correct dispenser slots and is rewarded or punished in real time. At the end of the game, a score is given and the user can register in a leaderboard.

  8. Identifying complications of interventional procedures from UK routine healthcare databases: a systematic search for methods using clinical codes.

    Science.gov (United States)

    Keltie, Kim; Cole, Helen; Arber, Mick; Patrick, Hannah; Powell, John; Campbell, Bruce; Sims, Andrew

    2014-11-28

    Several authors have developed and applied methods to routine data sets to identify the nature and rate of complications following interventional procedures. But, to date, there has been no systematic search for such methods. The objective of this article was to find, classify and appraise published methods, based on analysis of clinical codes, which used routine healthcare databases in a United Kingdom setting to identify complications resulting from interventional procedures. A literature search strategy was developed to identify published studies that referred, in the title or abstract, to the name or acronym of a known routine healthcare database and to complications from procedures or devices. The following data sources were searched in February and March 2013: Cochrane Methods Register, Conference Proceedings Citation Index - Science, Econlit, EMBASE, Health Management Information Consortium, Health Technology Assessment database, MathSciNet, MEDLINE, MEDLINE in-process, OAIster, OpenGrey, Science Citation Index Expanded and ScienceDirect. Of the eligible papers, those which reported methods using clinical coding were classified and summarised in tabular form using the following headings: routine healthcare database; medical speciality; method for identifying complications; length of follow-up; method of recording comorbidity. The benefits and limitations of each approach were assessed. From 3688 papers identified from the literature search, 44 reported the use of clinical codes to identify complications, from which four distinct methods were identified: 1) searching the index admission for specified clinical codes, 2) searching a sequence of admissions for specified clinical codes, 3) searching for specified clinical codes for complications from procedures and devices within the International Classification of Diseases 10th revision (ICD-10) coding scheme which is the methodology recommended by NHS Classification Service, and 4) conducting manual clinical

  9. Are routine visits to oncology clinics the most appropriate way to follow-up breast cancer patients?

    International Nuclear Information System (INIS)

    Kirkbride, Peter; Vallis, Katherine

    1997-01-01

    Purpose The routine follow-up at oncology clinics, of patients treated for breast cancer is believed to serve two purposes: to facilitate early detection of loco-regional recurrences and new primary tumors, and to provide psychological support for patients. Since it does not translate into improved survival, early detection of distant metastatic disease is not a priority. The purpose of this study was to determine the efficacy of routine clinic review in detecting loco-regional relapse following treatment for breast cancer. Materials and Methods The charts of all 579 patients with stage I, II and III breast cancer seen for the first time at our institution in 1982 were reviewed. Treatment consisted of mastectomy (367 cases), lumpectomy alone (53), or lumpectomy plus radiotherapy (159). Follow-up policy stipulated that patients were seen every 3 months for the first 2 years after primary treatment, every 6 months for the next 3 years and annually thereafter. Annual mammograms were performed. Results Thirteen patients were lost to follow-up during the 14 year study period. Loco-regional recurrence was diagnosed in 184 patients. Recurrent disease were detected by the patient (79 cases, 45%), at routine mammography (13 cases, 7%), at visits to physicians other than oncologists(40 cases, 22%). In 18 cases, the method of detection was unknown and only 34 (18%) loco-regional recurrences were detected at routine visits to oncology clinics. It is calculated that this group of patients attended approximately 11,000 follow-up clinic appointments over the period in question. Even if we assume that the 18 cases in which the method of detection was unknown were in fact detected at a visit to an oncology clinic, then the rate of detection is only 1 local recurrence per 212 visits. Conclusion Given the apparent limitations of routine follow-up, other methods of surveillance such as open access to a Breast Cancer Resource Centre merit investigation. It is imperative that non

  10. Clinical applications of MS-based protein quantification.

    Science.gov (United States)

    Sabbagh, Bassel; Mindt, Sonani; Neumaier, Michael; Findeisen, Peter

    2016-04-01

    Mass spectrometry-based assays are increasingly important in clinical laboratory medicine and nowadays are already commonly used in several areas of routine diagnostics. These include therapeutic drug monitoring, toxicology, endocrinology, pediatrics, and microbiology. Accordingly, some of the most common analyses are therapeutic drug monitoring of immunosuppressants, vitamin D, steroids, newborn screening, and bacterial identification. However, MS-based quantification of peptides and proteins for routine diagnostic use is rather rare up to now despite excellent analytical specificity and good sensitivity. Here, we want to give an overview over current fit-for-purpose assays for MS-based protein quantification. Advantages as well as challenges of this approach will be discussed with focus on feasibility for routine diagnostic use. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Health status in routine clinical practice: validity of the clinical COPD questionnaire at the individual patient level

    Directory of Open Access Journals (Sweden)

    de Vos Barbara

    2010-11-01

    Full Text Available Abstract Background There is a growing interest to use health status or disease control questionnaires in routine clinical practice. However, the validity of most questionnaires is established using techniques developed for group level validation. This study examines a new method, using patient interviews, to validate a short health status questionnaire, the Clinical COPD Questionnaire (CCQ, at the individual patient level. Methods Patients with COPD who visited an outpatient clinic completed the CCQ before the consultation, and the specialist physician completed it after the consultation. After the consultation all patients had a semi-structured in-depth interview. The patients' CCQ scores were compared with those of the treating clinician, and with mean scores from 5 clinicians from a pool of 20 who scored the CCQ after reading the transcript of the in-depth interviews only. Agreement was assessed using Lin's concordance correlation coefficient (CCC, and Blant and Altman plots. Interviews with patients with low agreement were reviewed for possible explanations. Results A total of 44 COPD patients (32 male, mean age 66 years, FEV1 45% of predicted participated. Agreement between the patients' CCQ scores and those of the treating clinicians (CCC = 0.87 and the mean score of the reviewing clinicians (CCC = 0.86 was very high. No systematic error was detected. No explanation for individuals with low agreement was found. Conclusion The validity of the CCQ on the individual patient level, as assessed by these methods, is good. Individual health status assessment with the CCQ is therefore sufficiently accurate to be used in routine clinical practice.

  12. The clinical value of daily routine chest radiographs in a mixed medical-surgical intensive care unit is low

    NARCIS (Netherlands)

    Graat, Marleen E.; Choi, Goda; Wolthuis, Esther K.; Korevaar, Johanna C.; Spronk, Peter E.; Stoker, Jaap; Vroom, Margreeth B.; Schultz, Marcus J.

    2006-01-01

    INTRODUCTION: The clinical value of daily routine chest radiographs (CXRs) in critically ill patients is unknown. We conducted this study to evaluate how frequently unexpected predefined major abnormalities are identified with daily routine CXRs, and how often these findings lead to a change in care

  13. A radiochemical assay for biotin in biological materials

    International Nuclear Information System (INIS)

    Hood, R.L.

    1975-01-01

    A radiochemical assay for biotin is described. The assay was sensitive to one nanogram and simple enough for routine biotin analyses. The assay yielded results which were comparable to those obtained from a microbiological assay using Lactobacillus plantarum. (author)

  14. Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination

    NARCIS (Netherlands)

    Anckaert, E.; Öktem, M.; Thies, A.; Cohen-Bacrie, M.; Daan, N. M P; Schiettecatte, J.; Müller, C.; Topcu, D.; Gröning, A.; Ternaux, F.; Engel, C.; Engelmann, S.; Milczynski, C.

    2016-01-01

    Objectives: Anti-Müllerian hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The

  15. Real-time patient survey data during routine clinical activities for rapid-cycle quality improvement.

    Science.gov (United States)

    Wofford, James Lucius; Campos, Claudia L; Jones, Robert E; Stevens, Sheila F

    2015-03-12

    Surveying patients is increasingly important for evaluating and improving health care delivery, but practical survey strategies during routine care activities have not been available. We examined the feasibility of conducting routine patient surveys in a primary care clinic using commercially available technology (Web-based survey creation, deployment on tablet computers, cloud-based management of survey data) to expedite and enhance several steps in data collection and management for rapid quality improvement cycles. We used a Web-based data management tool (survey creation, deployment on tablet computers, real-time data accumulation and display of survey results) to conduct four patient surveys during routine clinic sessions over a one-month period. Each survey consisted of three questions and focused on a specific patient care domain (dental care, waiting room experience, care access/continuity, Internet connectivity). Of the 727 available patients during clinic survey days, 316 patients (43.4%) attempted the survey, and 293 (40.3%) completed the survey. For the four 3-question surveys, the average time per survey was overall 40.4 seconds, with a range of 5.4 to 20.3 seconds for individual questions. Yes/No questions took less time than multiple choice questions (average 9.6 seconds versus 14.0). Average response time showed no clear pattern by order of questions or by proctor strategy, but monotonically increased with number of words in the question (30 words)-8.0, 11.8, 16.8, seconds, respectively. This technology-enabled data management system helped capture patient opinions, accelerate turnaround of survey data, with minimal impact on a busy primary care clinic. This new model of patient survey data management is feasible and sustainable in a busy office setting, supports and engages clinicians in the quality improvement process, and harmonizes with the vision of a learning health care system.

  16. Development and validation of receptor occupancy pharmacodynamic assays used in the clinical development of the monoclonal antibody vedolizumab.

    Science.gov (United States)

    Wyant, Tim; Estevam, Jose; Yang, Lili; Rosario, Maria

    2016-03-01

    Vedolizumab is a monoclonal antibody approved for use in ulcerative colitis and Crohn's disease. By specifically binding to α4 β7 integrin, vedolizumab prevents trafficking of lymphocytes to the gut, thereby interfering with disease pathology. During the clinical development program, the pharmacodynamic effect of vedolizumab was evaluated by 2 flow cytometry receptor occupancy assays: act-1 (ACT-1) and mucosal addressin cell adhesion molecule-1 (MAdCAM-1). Here we describe the development and validation of these assays. The ACT-1 assay is a receptor occupancy free-site assay that uses a monoclonal antibody with the same binding epitope as vedolizumab to detect free (unbound) sites on α4 β7 integrin. The MAdCAM-1 assay used a soluble version of the natural ligand for α4 β7 integrin to detect free sites. The assays were validated using a fit-for-purpose approach throughout the clinical development of vedolizumab. Both the ACT-1 assay and the MAdCAM-1 assay demonstrated acceptable reproducibility and repeatability. The assays were sufficiently stable to allow for clinical use. During clinical testing the assays demonstrated that vedolizumab was able to saturate peripheral cells at all doses tested. Two pharmacodynamic receptor occupancy assays were developed and validated to assess the effect of vedolizumab on peripheral blood cells. The results of these assays demonstrated the practical use of flow cytometry to examine pharmacodynamic response in clinical trials. © 2015 International Clinical Cytometry Society.

  17. Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum.

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona; Sambri, Vittorio

    2015-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  18. A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels.

    Science.gov (United States)

    Geib, Timon; Meier, Florian; Schorr, Pascal; Lammert, Frank; Stokes, Caroline S; Volmer, Dietrich A

    2015-01-01

    This short application note describes a simple and automated assay for determination of 25-hydroxyvitamin D (25(OH)D) levels in very small volumes of human serum. It utilizes commercial 96-well micro-extraction plates with commercial 25(OH)D isotope calibration and quality control kits. Separation was achieved using a pentafluorophenyl liquid chromatography column followed by multiple reaction monitoring-based quantification on an electrospray triple quadrupole mass spectrometer. Emphasis was placed on providing a simple assay that can be rapidly established in non-specialized laboratories within days, without the need for laborious and time consuming sample preparation steps, advanced calibration or data acquisition routines. The analytical figures of merit obtained from this assay compared well to established assays. To demonstrate the applicability, the assay was applied to analysis of serum samples from patients with chronic liver diseases and compared to results from a routine clinical immunoassay. Copyright © 2015 John Wiley & Sons, Ltd.

  19. A new DPYD genotyping assay for improving the safety of 5-fluorouracil therapy.

    Science.gov (United States)

    Sistonen, Johanna; Smith, Chingying; Fu, Yung-Kang; Largiadèr, Carlo R

    2012-12-24

    Chemotherapeutic use of 5-fluorouracil (5FU) is compromised by 10-20% of patients developing severe toxicity. Recently described genetic variation in dihydropyrimidine dehydrogenase (DPYD) has been shown to be a major predictor of 5FU toxicity. Here, we describe a new genotyping assay for routine clinical use that covers all the major DPYD risk variants. Genomic regions targeting DPYD risk variants (c.1129-5923C>G, c.1679T>G/A, c.1905+1G>A, c.2846A>T) and additional markers (c.234-123G>C, c.496A>G, c.775A>G) were amplified in a multiplex PCR reaction. The subsequent steps including allele-specific primer extension, hybridization of the primers to a microarray, scanning of the array, and data analysis were automated within the INFINITI® Analyzer (AutoGenomics). The assay was validated by analyzing 107 blood samples obtained from patients previously re-sequenced for the DPYD. The genotypes obtained with the developed assay were 100% concordant with the re-sequencing. The procedure is suitable for routine clinical use since the results are obtained within one day. For heterozygous risk variant carriers (~7% of Europeans), the treatment can be adjusted by 5FU dose reduction, whereas carriers of two risk alleles should be treated with an alternative therapy. The developed assay provides a novel tool to improve the safety of commonly used 5FU-based chemotherapies. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine. Part 3: Technical Validation of Immunohistochemistry (IHC) Assays in Clinical IHC Laboratories.

    Science.gov (United States)

    Torlakovic, Emina E; Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Vyberg, Mogens; Zhou, Xiaoge; Taylor, Clive R

    2017-03-01

    Validation of immunohistochemistry (IHC) assays is a subject that is of great importance to clinical practice as well as basic research and clinical trials. When applied to clinical practice and focused on patient safety, validation of IHC assays creates objective evidence that IHC assays used for patient care are "fit-for-purpose." Validation of IHC assays needs to be properly informed by and modeled to assess the purpose of the IHC assay, which will further determine what sphere of validation is required, as well as the scope, type, and tier of technical validation. These concepts will be defined in this review, part 3 of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  1. Effectiveness of behavioral parent training for children with ADHD in routine clinical practice : A randomized controlled study

    NARCIS (Netherlands)

    van den Hoofdakker, Barbara J.; Van der Veen-Mulders, Lianne; Sytema, Sjoerd; Emmelkamp, Paul M. G.; Minderaa, Ruud B.; Nauta, Maaike H.

    2007-01-01

    Objective: To investigate the effectiveness of behavioral parent training (BPT) as adjunct to routine clinical care (RCC). Method: After a first phase of RCC, 94 children with attention-deficit/hyperactivity disorder (ADHD) ages 4-12, all referred to a Dutch outpatient mental health clinic, were

  2. The effectiveness of online cognitive behavioral treatment in routine clinical practice.

    Directory of Open Access Journals (Sweden)

    Jeroen Ruwaard

    Full Text Available Randomized controlled trails have identified online cognitive behavioral therapy as an efficacious intervention in the management of common mental health disorders.To assess the effectiveness of online CBT for different mental disorders in routine clinical practice.An uncontrolled before-after study, with measurements at baseline, posttest, 6-week follow-up, and 1-year follow-up.1500 adult patients (female: 67%; mean age: 40 years with a GP referral for psychotherapy were treated at a Dutch online mental health clinic for symptoms of depression (n = 413, panic disorder (n = 139, posttraumatic stress (n = 478, or burnout (n = 470.Manualized, web-based, therapist-assisted CBT, of which the efficacy was previously demonstrated in a series of controlled trials. Standardized duration of treatment varied from 5 weeks (online CBT for Posttraumatic stress to 16 weeks (online CBT for Depression.Validated self-report questionnaires of specific and general psychopathology, including the Beck Depression Inventory, the Impact of Event Scale, the Panic Disorder Severity Scale-Self Report, the Oldenburg Burnout Inventory, and the Depression Anxiety Stress Scales.Treatment adherence was 71% (n = 1071. Study attrition was 21% at posttest, 33% at 6-week FU and 65% at 1-year FU. Mixed-model repeated measures regression identified large short-term reductions in all measures of primary symptoms (d = 1.9±0.2 to d = 1.2±0.2; P<.001, which sustained up to one year after treatment. At posttest, rates of reliable improvement and recovery were 71% and 52% in the completer sample (full sample: 55%/40%. Patient satisfaction was high.Results suggest that online therapist-assisted CBT may be as effective in routine practice as it is in clinical trials. Although pre-treatment withdrawal and long-term outcomes require further study, results warrant continued implementation of online CBT.

  3. COPD management: role of symptom assessment in routine clinical practice

    Science.gov (United States)

    van der Molen, Thys; Miravitlles, Marc; Kocks, Janwillem WH

    2013-01-01

    Patients with chronic obstructive pulmonary disease (COPD) present with a variety of symptoms that significantly impair health-related quality of life. Despite this, COPD treatment and its management are mainly based on lung function assessments. There is increasing evidence that conventional lung function measures alone do not correlate well with COPD symptoms and their associated impact on patients’ everyday lives. Instead, symptoms should be assessed routinely, preferably by using patient-centered questionnaires that provide a more accurate guide to the actual burden of COPD. Numerous questionnaires have been developed in an attempt to find a simple and reliable tool to use in everyday clinical practice. In this paper, we review three such patient-reported questionnaires recommended by the latest Global Initiative for Chronic Obstructive Lung Disease guidelines, ie, the modified Medical Research Council questionnaire, the clinical COPD questionnaire, and the COPD Assessment Test, as well as other symptom-specific questionnaires that are currently being developed. PMID:24143085

  4. Tissue factor activated thromboelastography correlates to clinical signs of bleeding in dogs

    DEFF Research Database (Denmark)

    Wiinberg, Bo; Jensen, Asger Lundorff; Rozanski, Elizabeth

    2009-01-01

    The ability of a laboratory assay to correlate to clinical phenotype is crucial for the accurate diagnosis and monitoring of haemostasis and is therefore challenging with currently used routine haemostasis assays. Thromboelastography (TEG) is increasingly used to evaluate haemostasis in humans...... and may well be of value in the workup of dogs suspected of having a haemostatic disorder. This study was undertaken to evaluate prospectively how tissue factor (TF) activated TEG correlated to clinical signs of bleeding in dogs, compared to a routine coagulation profile. A prospective case-control study...... was performed over a 2 year period from 2004-2006. Eligible dogs were those where the primary clinician requested a coagulation profile to evaluate haemostasis. The dogs were simultaneously evaluated with a TF-activated TEG assay. Twenty-seven dogs, characterised as hypo-coagulable based on the TEG parameter G...

  5. Fibrin related antigens: assay development, clinical and kinetic studies

    Energy Technology Data Exchange (ETDEWEB)

    Kruskal, J B

    1987-08-01

    This thesis describes an assay which is able to measure and to determine the proportions of fibrin- and fibrinogen-related antigens (FRA) present in clinical samples. No assay exists at present which is capable of distinguishing between fibrin and fibrinogen degradation products concurrently and in a clinical setting. The assay may be used as a tool with which to gain further insight to pathophysiology of disorders characterized by activation of the coagulation and fibrinolytic pathways. This study provides and analysis of the FRA profiles in patients with disorders characterised by possible enhanced fibrinolytic activity. Studies have been undertaken on patients with acute and chronic liver diseases, on patients with the various syndromes of coronary artery disease and on patients with insulin-dependent diabetes mellitus with and without evidence of microvascular disease. Certain observations made it evident that further studies were required in order to explain previously undocumented fibrinolytic abnormalities in certain patient groups. Data obtained from patients with liver disease provided information compatible with the activation of their fibrinolytic pathways. The initial scope of this study was then extended to further investigate the deranged haemostatic mechanisms in patients with severe liver diseases. Kinetic studies were performed which required the development of specific technology to be able to measure certain previously undertermined parameters. Mathematical models describing the rates of fibrin formation and lysis were developed for human studies. Fibrin-derived D-dimer was radiolabelled and its validity as and intravenous tracer and maker of fibrin degradation established.

  6. Quality Control Assays for Clinical-Grade Human Mesenchymal Stromal Cells: Validation Strategy.

    Science.gov (United States)

    Radrizzani, Marina; Soncin, Sabrina; Bolis, Sara; Lo Cicero, Viviana; Andriolo, Gabriella; Turchetto, Lucia

    2016-01-01

    The present chapter focuses on the validation of the following analytical methods for the control of mesenchymal stromal cells (MSC) for cell therapy clinical trials: Microbiological control for cellular product Endotoxin assay Mycoplasma assay Cell count and viability Immunophenotype Clonogenic potential (CFU-F assay) In our lab, these methods are in use for product release, process control or control of the biological starting materials. They are described in detail in the accompanying Chapter 19.For each method, validation goals and strategy are presented, and a detailed experimental scheme is proposed.

  7. Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.

    Science.gov (United States)

    White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin

    2018-05-15

    Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia

  8. [Comparison of the performance of the ECLusys anti-HCV reagent with the Lumipulse f and HISCL 2000-i HCVAb assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-09-01

    We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.

  9. A MIQE-compliant real-time PCR assay for Aspergillus detection.

    Directory of Open Access Journals (Sweden)

    Gemma L Johnson

    Full Text Available The polymerase chain reaction (PCR is widely used as a diagnostic tool in clinical laboratories and is particularly effective for detecting and identifying infectious agents for which routine culture and microscopy methods are inadequate. Invasive fungal disease (IFD is a major cause of morbidity and mortality in immunosuppressed patients, and optimal diagnostic criteria are contentious. Although PCR-based methods have long been used for the diagnosis of invasive aspergillosis (IA, variable performance in clinical practice has limited their value. This shortcoming is a consequence of differing sample selection, collection and preparation protocols coupled with a lack of standardisation of the PCR itself. Furthermore, it has become clear that the performance of PCR-based assays in general is compromised by the inadequacy of experimental controls, insufficient optimisation of assay performance as well as lack of transparency in reporting experimental details. The recently published "Minimum Information for the publication of real-time Quantitative PCR Experiments" (MIQE guidelines provide a blueprint for good PCR assay design and unambiguous reporting of experimental detail and results. We report the first real-time quantitative PCR (qPCR assay targeting Aspergillus species that has been designed, optimised and validated in strict compliance with the MIQE guidelines. The hydrolysis probe-based assay, designed to target the 18S rRNA DNA sequence of Aspergillus species, has an efficiency of 100% (range 95-107%, a dynamic range of at least six orders of magnitude and limits of quantification and detection of 6 and 0.6 Aspergillus fumigatus genomes, respectively. It does not amplify Candida, Scedosporium, Fusarium or Rhizopus species and its clinical sensitivity is demonstrated in histological material from proven IA cases, as well as concordant PCR and galactomannan data in matched broncho-alveolar lavage and blood samples. The robustness

  10. Clinical Evaluation of an Affordable Qualitative Viral Failure Assay for HIV Using Dried Blood Spots in Uganda.

    Science.gov (United States)

    Balinda, Sheila N; Ondoa, Pascale; Obuku, Ekwaro A; Kliphuis, Aletta; Egau, Isaac; Bronze, Michelle; Kasambula, Lordwin; Schuurman, Rob; Spieker, Nicole; Rinke de Wit, Tobias F; Kityo, Cissy

    2016-01-01

    WHO recommends regular viral load (VL) monitoring of patients on antiretroviral therapy (ART) for timely detection of virological failure, prevention of acquired HIV drug resistance (HIVDR) and avoiding unnecessary switching to second-line ART. However, the cost and complexity of routine VL testing remains prohibitive in most resource limited settings (RLS). We evaluated a simple, low-cost, qualitative viral-failure assay (VFA) on dried blood spots (DBS) in three clinical settings in Uganda. We conducted a cross-sectional diagnostic accuracy study in three HIV/AIDS treatment centres at the Joint Clinical Research Centre in Uganda. The VFA employs semi-quantitative detection of HIV-1 RNA amplified from the LTR gene. We used paired dry blood spot (DBS) and plasma with the COBASAmpliPrep/COBASTaqMan, Roche version 2 (VLref) as the reference assay. We used the VFA at two thresholds of viral load, (>5,000 or >1,000 copies/ml). 496 paired VFA and VLref results were available for comparative analysis. Overall, VFA demonstrated 78.4% sensitivity, (95% CI: 69.7%-87.1%), 93% specificity (95% CI: 89.7%-96.4%), 89.3% accuracy (95% CI: 85%-92%) and an agreement kappa = 0.72 as compared to the VLref. The predictive values of positivity and negativity among patients on ART for >12 months were 72.7% and 99.3%, respectively. VFA allowed 89% of correct classification of VF. Only 11% of the patients were misclassified with the potential of unnecessary or late switch to second-line ART. Our findings present an opportunity to roll out simple and affordable VL monitoring for HIV-1 treatment in RLS.

  11. Clinical Evaluation of an Affordable Qualitative Viral Failure Assay for HIV Using Dried Blood Spots in Uganda.

    Directory of Open Access Journals (Sweden)

    Sheila N Balinda

    Full Text Available WHO recommends regular viral load (VL monitoring of patients on antiretroviral therapy (ART for timely detection of virological failure, prevention of acquired HIV drug resistance (HIVDR and avoiding unnecessary switching to second-line ART. However, the cost and complexity of routine VL testing remains prohibitive in most resource limited settings (RLS. We evaluated a simple, low-cost, qualitative viral-failure assay (VFA on dried blood spots (DBS in three clinical settings in Uganda.We conducted a cross-sectional diagnostic accuracy study in three HIV/AIDS treatment centres at the Joint Clinical Research Centre in Uganda. The VFA employs semi-quantitative detection of HIV-1 RNA amplified from the LTR gene. We used paired dry blood spot (DBS and plasma with the COBASAmpliPrep/COBASTaqMan, Roche version 2 (VLref as the reference assay. We used the VFA at two thresholds of viral load, (>5,000 or >1,000 copies/ml.496 paired VFA and VLref results were available for comparative analysis. Overall, VFA demonstrated 78.4% sensitivity, (95% CI: 69.7%-87.1%, 93% specificity (95% CI: 89.7%-96.4%, 89.3% accuracy (95% CI: 85%-92% and an agreement kappa = 0.72 as compared to the VLref. The predictive values of positivity and negativity among patients on ART for >12 months were 72.7% and 99.3%, respectively.VFA allowed 89% of correct classification of VF. Only 11% of the patients were misclassified with the potential of unnecessary or late switch to second-line ART. Our findings present an opportunity to roll out simple and affordable VL monitoring for HIV-1 treatment in RLS.

  12. Performance evaluation of the Cobas TaqMan MTB assay on respiratory specimens according to clinical application

    Directory of Open Access Journals (Sweden)

    Jong Eun Park

    2017-11-01

    Full Text Available Objective: To evaluate the performance of the Cobas TaqMan MTB assay (Cobas assay with respect to its clinical application. Methods: This was a retrospective analysis of 1154 results from 1034 patients for whom mycobacterial cultures and the Cobas assay were performed simultaneously. Based on the patient medical records, two categories of clinical application were defined: (1 the diagnosis of patients with a high probability of pulmonary tuberculosis according to clinical and radiological features (n = 128, and (2 the exclusion of tuberculosis in clinically indeterminate patients (n = 1026. Standard culture was used as the reference method. Results: The sensitivity of the Cobas assay for the detection of Mycobacterium tuberculosis was 70.4% (95% confidence interval (CI 49.7–85.5% for category 1, but only 25.0% (95% CI 4.5–64.4% for category 2. The specificity was ≥95.0% for both categories. The positive predictive value was 79.2% (95% CI 57.3–92.1% for category 1 and 33.3% (95% CI 6.0–75.9% for category 2, while the negative predictive value was 92.3% (95% CI 85.0–96.4% for category 1 and 99.4% (95% CI 98.7–99.8% for category 2. Conclusions: The results of this study indicate that Cobas assay results must be interpreted carefully according to the clinical purpose of the assay. Keywords: Mycobacterium tuberculosis, Pulmonary tuberculosis, Cobas TaqMan MTB assay, Korea

  13. Functional assays for analysis of variants of uncertain significance in BRCA2

    DEFF Research Database (Denmark)

    Guidugli, Lucia; Carreira, Aura; Caputo, Sandrine M

    2014-01-01

    Missense variants in the BRCA2 gene are routinely detected during clinical screening for pathogenic mutations in patients with a family history of breast and ovarian cancer. These subtle changes frequently remain of unknown clinical significance because of the lack of genetic information that may...... of uncertain significance analyzed, and describe a validation set of (genetically) proven pathogenic and neutral missense variants to serve as a golden standard for the validation of each assay. Guidelines are proposed to enable implementation of laboratory-based methods to assess the impact of the variant...

  14. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  15. Immune Monitoring in Cancer Vaccine Clinical Trials: Critical Issues of Functional Flow Cytometry-Based Assays

    Directory of Open Access Journals (Sweden)

    Iole Macchia

    2013-01-01

    Full Text Available The development of immune monitoring assays is essential to determine the immune responses against tumor-specific antigens (TSAs and tumor-associated antigens (TAAs and their possible correlation with clinical outcome in cancer patients receiving immunotherapies. Despite the wide range of techniques used, to date these assays have not shown consistent results among clinical trials and failed to define surrogate markers of clinical efficacy to antitumor vaccines. Multiparameter flow cytometry- (FCM- based assays combining different phenotypic and functional markers have been developed in the past decade for informative and longitudinal analysis of polyfunctional T-cells. These technologies were designed to address the complexity and functional heterogeneity of cancer biology and cellular immunity and to define biomarkers predicting clinical response to anticancer treatment. So far, there is still a lack of standardization of some of these immunological tests. The aim of this review is to overview the latest technologies for immune monitoring and to highlight critical steps involved in some of the FCM-based cellular immune assays. In particular, our laboratory is focused on melanoma vaccine research and thus our main goal was the validation of a functional multiparameter test (FMT combining different functional and lineage markers to be applied in clinical trials involving patients with melanoma.

  16. Development and application of two independent real-time PCR assays to detect clinically relevant Mucorales species.

    Science.gov (United States)

    Springer, Jan; Goldenberger, Daniel; Schmidt, Friderike; Weisser, Maja; Wehrle-Wieland, Elisabeth; Einsele, Hermann; Frei, Reno; Löffler, Jürgen

    2016-03-01

    PCR-based detection of Mucorales species could improve diagnosis of suspected invasive fungal infection, leading to a better patient outcome. This study describes two independent probe-based real-time PCR tests for detection of clinically relevant Mucorales, targeting specific fragments of the 18S and the 28S rRNA genes. Both assays have a short turnaround time, allow fast, specific and very sensitive detection of clinically relevant Mucorales and have the potential to be used as quantitative tests. They were validated on various clinical samples (fresh and formalin-fixed paraffin-embedded specimens, mainly biopsies, n = 17). The assays should be used as add-on tools to complement standard techniques; a combined approach of both real-time PCR assays has 100 % sensitivity. Genus identification by subsequent sequencing is possible for amplicons of the 18S PCR assay. In conclusion, combination of the two independent Mucorales assays described in this study, 18S and 28S, detected all clinical samples associated with proven Mucorales infection (n = 10). Reliable and specific identification of Mucorales is a prerequisite for successful antifungal therapy as these fungi show intrinsic resistance to voriconazole and caspofungin.

  17. Toshiba General Hospital PACS for routine in- and outpatient clinics

    Science.gov (United States)

    Toshimitsu, Akihiro; Okazaki, Nobuo; Kura, Hiroyuki; Nishihara, Eitaro; Tsubura, Shinichi

    1996-05-01

    The Toshiba General Hospital introduced a departmental RIS/PACS (Radiology Information System/Picture Archiving and Communication System) in the radiology department in May, 1993. It has been used routinely since that time. In order to provide efficient means for clinicians to find and read many images, the system has been expanded to the neurosurgery and urology clinics and wards since May, 1995, and five image referring workstations now provide digital images to clinicians. In this paper we discuss an algorithm for image migration, one of the key issues to accomplish the expansion to outpatient clinics successfully, and propose the WYWIWYG (what you want is what you get) image transfer logic. This is the logic used to transfer images that physicians require refer without increasing the traffic between the image server and referring workstations. We accomplish the WYWIWYG logic by prioritizing exams the physicians have not yet viewed and by finding historical exams according to the modality, anatomy, and marking. Clinicians gave us comments from their first use of the system and suggested that the PACS enables clinicians to review images more efficiently compared to a film-based system. Our experience suggests that it is a key to the effective application of PACS in outpatient clinics to incorporate consideration patterns of clinicians on the migration algorithm.

  18. Development and clinical application of a highly sensitive hCG-β radioimmuno assay with a critical view to cross-reaction with LH

    International Nuclear Information System (INIS)

    Schuessler, B.

    1979-01-01

    A highly sensitive hCG-β-RIA with a lower detection limit of 1 mIU/ml was developed with an hCG-β-antiserum. Despite the crossreaction with LH-concentrations of 30 mIU/ml - 150mIU/ml ocurring between 1 mIU/ml and 5 mIU/ml, also in this region a definite statement on the hCG-concentration could be made, by comparison with the values developed in LH-RIA. The assay for the hCG-determination was applied in carcinomas of the uterine cervix (47%), ovaries (25%), body of the uterus (25%), mamma (17,6B), and prostate (5,8%). Another assay with a sensitivity of 5 mIU/ml was arranged for clinical routine examinations of chorionepithelioma and testis-carcinoma. In contrast to the first two systems which had a reaction time of appr. 100 hrs, we obtained safe results with another hCG-β-RIA with low antibodytiters after 110 min. The sensitivity was 15 mIU/ml. The procedure was found to be valuable for the exclusion of EU-gravidities. (orig.) [de

  19. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  20. Routine resite of peripheral intravenous devices every 3 days did not reduce complications compared with clinically indicated resite: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Rickard Claire M

    2010-09-01

    Full Text Available Abstract Background Peripheral intravenous device (IVD complications were traditionally thought to be reduced by limiting dwell time. Current recommendations are to resite IVDs by 96 hours with the exception of children and patients with poor veins. Recent evidence suggests routine resite is unnecessary, at least if devices are inserted by a specialised IV team. The aim of this study was to compare the impact of peripheral IVD 'routine resite' with 'removal on clinical indication' on IVD complications in a general hospital without an IV team. Methods A randomised, controlled trial was conducted in a regional teaching hospital. After ethics approval, 362 patients (603 IVDs were randomised to have IVDs replaced on clinical indication (185 patients or routine change every 3 days (177 patients. IVDs were inserted and managed by the general hospital medical and nursing staff; there was no IV team. The primary endpoint was a composite of IVD complications: phlebitis, infiltration, occlusion, accidental removal, local infection, and device-related bloodstream infection. Results IVD complication rates were 68 per 1,000 IVD days (clinically indicated and 66 per 1,000 IVD days (routine replacement (P = 0.86; HR 1.03; 95% CI, 0.74-1.43. Time to first complication per patient did not differ between groups (KM with log rank, P = 0.53. There were no local infections or IVD-related bloodstream infections in either group. IV therapy duration did not differ between groups (P = 0.22, but more (P = 0.004 IVDs were placed per patient in the routine replacement (mean, 1.8 than the clinical indication group (mean, 1.5, with significantly higher hospital costs per patient (P Conclusions Resite on clinical indication would allow one in two patients to have a single cannula per course of IV treatment, as opposed to one in five patients managed with routine resite; overall complication rates appear similar. Clinically indicated resite would achieve savings in equipment

  1. The diagnostic value of the fibrinogen/fibrin fragment E antigen assay in clinically suspected deep vein thrombosis

    International Nuclear Information System (INIS)

    Zielinsky, A.; Hirsh, J.; Straumanis, G.; Carter, C.J.; Gent, M.; Sackett, D.L.; Hull, R.; Kelton, J.G.; Powers, P.; Turpie, A.G.

    1982-01-01

    We have evaluated the fibrinogen/fibrin fragment E antigen assay as a diagnostic test in patients with clinically suspected venous thrombosis by comparing the results of this assay with venography in 272 patients. The result of the fragment E antigen assay was elevated in 79 of 80 patients with positive venograms for recent venous thrombosis (sensitivity 99%) and within the normal range in 161 of 192 patients with normal venograms (specificity 84%). The fragment E assay was also evaluated in 130 medical and surgical controls without evidence of venous thrombosis by leg scanning and the test was found to be relatively nonspecific. However, in the patient group under study, a correct clinical diagnosis of no thrombosis, based on a normal fragment E result, was made in 161 of 162 cases (negative predictive value of 99%). Therefore, a normal test result effectively excludes a diagnosis of venous thrombosis in clinically symptomatic patients. The assay, as currently performed, is technically demanding and takes 24 hr to complete. Therefore, it will have to be simplified before it can be applied to clinical practice

  2. The diagnostic value of the fibrinogen/fibrin fragment E antigen assay in clinically suspected deep vein thrombosis

    International Nuclear Information System (INIS)

    Zielinsky, A.; Hirsh, J.; Straumanis, G.; Carter, C.J.; Gent, M.; Sackett, D.L.; Hull, R.; Kelton, J.G.; Powers, P.

    1982-01-01

    We have evaluated the fibrinogen/fibrin fragment E antigen assay as a diagnostic test in patients with clinically suspected venous thrombosis by comparing the results of this assay with venography in 272 patients. The result of the fragment E antigen assay was elevated in 79 of 80 patients with positive venograms for recent venous thrombosis (sensitivity 99%) and within the normal range in 161 of 192 patients with normal venograms (specificity 84%). The fragment E assay was also evaluated in 130 medical and surgical controls without evidence of venous thrombosis by leg scanning and the test was found to be relatively nonspecific. However, in the patient group under study, a correct clinical diagnosis of no thrombosis, based on a normal fragment E result, was made in 161 of 162 cases (negative predictive value 99%). Therefore, a normal test result effectively excludes a diagnosis of venous thrombosis in clinically symptomatic patients. The assay, as currently performed, is technically demanding and takes 24 hr to complete. Therefore, it will have to be simplified before it can be applied to clinical practice

  3. Adherence to fesoterodine in women with overactive bladder in routine clinical practice.

    Science.gov (United States)

    Simó, M; Porta, O; Pubill, J; Castillo, M T; Mora, I; Huguet, E; Ortega, J A; Martínez, E

    2015-05-01

    To assess the short-term compliance with fesoterodine treatment and to identify the reasons for lack of adherence and discontinuation in routine clinical practice. The secondary aim was to estimate the patient-reported outcomes. This was an observational retrospective, multicenter study conducted in a sample of women with overactive bladder on fesoterodine treatment for at least three months. Adherence to medication was assessed using the Morisky-Green test. Patient-reported outcomes were assessed using the Incontinence Questionnaire Short Form (ICIQ-SF), Overactive Bladder Questionnaire Short Form (OAB-qSF), and Treatment Benefit Scale (TBS). One hundred and twenty women with a mean age [standard deviation (SD)] of 62.2 (12.0) years with severe OAB [mean (SD) ICIQ-SF score 13.2 (4.0)] were included. 42.1% of the patients were considered compliant with fesoterodine treatment. The main causes for non-compliance/discontinuation stated by the remaining 57.9% of the patients were adverse events (62.2%) and lack of clinical benefits (20.0%). The illness status as well as the patient-perceived bother occasioned by the OAB symptoms and their impact on the quality of life improved significantly after three months on fesoterodine treatment (p<0.0001). Most of the patients stated that the current state of their urinary problems had greatly improved/ improved. In routine clinical practice, a high percentage of patients were adherent to fesoterodine and perceived the benefit that the treatment provided them three months after starting treatment. However, more than half of the study population failed to comply or discontinued the treatment mainly due to intolerance or lack of efficacy. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Vitamin D assays: past and present debates, difficulties, and developments.

    Science.gov (United States)

    Fraser, William D; Milan, Anna M

    2013-02-01

    Clinical interest in Vitamin D and its purported roles not only in calcium and bone metabolism but in several other medical conditions (diabetes, cardiovascular disease, multiple sclerosis, cancer, psychiatric disorders, neuro-muscular disease) has led to a surge in laboratory requests for 25 hydroxy vitamin D and 1,25 dihydroxy vitamin D measurement. Circulating 25 hydroxy vitamin D concentration is routinely used as the best indicator of vitamin D status, but measurement of other metabolites, especially the physiologically active 1,25 dihyroxy vitamin D, are of clinical value. Over the last 40 years the development of assays for vitamin D and its metabolites from early competitive binding assays through to immunoassay and liquid chromatography aligned to mass spectrometry have demonstrated various analytical challenges, the advantages and disadvantages of each method are constantly changing with new technological developments. Immunoassay remains the predominant mode of measurement for 25-hydroxy vitamin D although problems with equimolar recovery of the D2 and D3 metabolites remain an issue. Standardisation of all assays has been improved but not resolved with the currently available reference materials as evidenced by the international vitamin D external quality assurance scheme, DEQAS. The choice of method for each laboratory remains a balance mainly between turn around time, convenience, cost and the specificity and accuracy of the information obtained. With increasing discussion and clinical interest surrounding other vitamin D metabolites the vitamin D assay debate is set to continue.

  5. A prospective study on the use of rivastigmine transdermal patch in Alzheimer's dementia in a routine clinical setting

    Directory of Open Access Journals (Sweden)

    Ejaz Nazir

    Full Text Available Abstract There is not much published literature on the use of rivastigmine patch in a "routine" clinical setting. Objectives: In this naturalistic longitudinal observational study we sought to evaluate the safety, tolerability and efficacy of the rivastigmine patch in patients with early and late onset moderate Alzheimer's disease in a routine clinical setting. Methods: Out of all routine clinical referrals, the first 30 patients with diagnosis of moderate Alzheimer's dementia who were started on rivastigmine patch were included in the study. Rivastigmine patch dose was titrated from 4.6 to 9.5 mg/ 24 hours as appropriate. The primary outcome measure was safety and tolerability, measured by the incidence of adverse events and discontinuation due to any reason. The secondary outcome measure was to examine improvement on global, functional and behavioral domains as demonstrated by the MMSE (Mini Mental State Examination score, BADLS (Bristol Activities of Daily Living Skills score, patient and carer feedback and clinical judgment. Results: Adverse events were reported in 20% of patients and 10% of total patients needed discontinuation of treatment. Improvement on global, functional and behavioral domains was observed in two thirds of patients whereas one third showed a relative decline. The most common side effect was skin irritation or erythema. Conclusions: The rivastigmine transdermal patch may provide a treatment option for those patients who require a change in their current oral cholinesterase inhibitor therapy due to safety or tolerability concerns.

  6. A Comprehensive Review on Clinical Applications of Comet Assay

    Science.gov (United States)

    Gunasekarana, Vidya; Chand, Parkash

    2015-01-01

    Increased levels of DNA damage and ineffective repair mechanisms are the underlying bio-molecular events in the pathogenesis of most of the life-threatening diseases like cancer and degenerative diseases. The sources of DNA damage can be either exogenous or endogenous in origin. Imbalance between the oxidants and antioxidants resulting in increased reactive oxygen species mostly accounts for the endogenously derived attacks on DNA. Among the various methods employed in the estimation of DNA damage, alkaline comet assay is proven to be a relatively simple and versatile tool in the assessment of DNA damage and also in determining the efficacy of DNA repair mechanism. The aim of this article is to review the application of comet assay in the field of medicine towards human biomonitoring, understanding the pathogenesis of cancer and progression of chronic and degenerative diseases, prediction of tumour radio & chemosensitivity and in male infertility. A standardized protocol and analysis system of various variants of comet assay in different types of cells, across the labs will be of useful and reliable clinical tool in the field of Medicine for the estimation of levels of DNA damage and repair mechanisms. PMID:25954633

  7. A simple coated-tube assay for alpha-foeto protein for clinical use

    International Nuclear Information System (INIS)

    Dakubu, S.; Ahene, I.S.; Foli, A.K.

    1977-01-01

    A standard method for coating plastic tubes with antiserum has been applied to coat tubes with rabbit antiserum to human alpha-foeto protein. The coated plastic tubes have been used to set up a radioimmunoassay system which is sensitive and convenient for use on the occasional clinical sample. For a successful coated-tube assay, it was found necessary to modify the final incubation mixture from what was suitable in a standard double antibody assay system. (orig.) [de

  8. Cost effectiveness analysis of clinically driven versus routine laboratory monitoring of antiretroviral therapy in Uganda and Zimbabwe.

    Directory of Open Access Journals (Sweden)

    Antonieta Medina Lara

    Full Text Available Despite funding constraints for treatment programmes in Africa, the costs and economic consequences of routine laboratory monitoring for efficacy and toxicity of antiretroviral therapy (ART have rarely been evaluated.Cost-effectiveness analysis was conducted in the DART trial (ISRCTN13968779. Adults in Uganda/Zimbabwe starting ART were randomised to clinically-driven monitoring (CDM or laboratory and clinical monitoring (LCM; individual patient data on healthcare resource utilisation and outcomes were valued with primary economic costs and utilities. Total costs of first/second-line ART, routine 12-weekly CD4 and biochemistry/haematology tests, additional diagnostic investigations, clinic visits, concomitant medications and hospitalisations were considered from the public healthcare sector perspective. A Markov model was used to extrapolate costs and benefits 20 years beyond the trial.3316 (1660LCM;1656CDM symptomatic, immunosuppressed ART-naive adults (median (IQR age 37 (32,42; CD4 86 (31,139 cells/mm(3 were followed for median 4.9 years. LCM had a mean 0.112 year (41 days survival benefit at an additional mean cost of $765 [95%CI:685,845], translating into an adjusted incremental cost of $7386 [3277,dominated] per life-year gained and $7793 [4442,39179] per quality-adjusted life year gained. Routine toxicity tests were prominent cost-drivers and had no benefit. With 12-weekly CD4 monitoring from year 2 on ART, low-cost second-line ART, but without toxicity monitoring, CD4 test costs need to fall below $3.78 to become cost-effective (<3xper-capita GDP, following WHO benchmarks. CD4 monitoring at current costs as undertaken in DART was not cost-effective in the long-term.There is no rationale for routine toxicity monitoring, which did not affect outcomes and was costly. Even though beneficial, there is little justification for routine 12-weekly CD4 monitoring of ART at current test costs in low-income African countries. CD4 monitoring

  9. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  10. The Lumipulse G HBsAg-Quant assay for screening and quantification of the hepatitis B surface antigen.

    Science.gov (United States)

    Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai

    2016-02-01

    Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, PLumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Application of statistical process control to qualitative molecular diagnostic assays.

    Science.gov (United States)

    O'Brien, Cathal P; Finn, Stephen P

    2014-01-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  12. Application of statistical process control to qualitative molecular diagnostic assays.

    Directory of Open Access Journals (Sweden)

    Cathal P O'brien

    2014-11-01

    Full Text Available Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control. Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply statistical process control to assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater samples with a resultant protracted time to detection. Modelled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of statistical process control to qualitative laboratory data.

  13. Application of statistical process control to qualitative molecular diagnostic assays

    LENUS (Irish Health Repository)

    O'Brien, Cathal P.

    2014-11-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  14. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    Science.gov (United States)

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  15. Clinical Assessment of a Nocardia PCR-Based Assay for Diagnosis of Nocardiosis.

    Science.gov (United States)

    Rouzaud, Claire; Rodriguez-Nava, Véronica; Catherinot, Emilie; Méchaï, Frédéric; Bergeron, Emmanuelle; Farfour, Eric; Scemla, Anne; Poirée, Sylvain; Delavaud, Christophe; Mathieu, Daniel; Durupt, Stéphane; Larosa, Fabrice; Lengelé, Jean-Philippe; Christophe, Jean-Louis; Suarez, Felipe; Lortholary, Olivier; Lebeaux, David

    2018-06-01

    The diagnosis of nocardiosis, a severe opportunistic infection, is challenging. We assessed the specificity and sensitivity of a 16S rRNA Nocardia PCR-based assay performed on clinical samples. In this multicenter study (January 2014 to April 2015), patients who were admitted to three hospitals and had an underlying condition favoring nocardiosis, clinical and radiological signs consistent with nocardiosis, and a Nocardia PCR assay result for a clinical sample were included. Patients were classified as negative control (NC) (negative Nocardia culture results and proven alternative diagnosis or improvement at 6 months without anti- Nocardia treatment), positive control (PC) (positive Nocardia culture results), or probable nocardiosis (positive Nocardia PCR results, negative Nocardia culture results, and no alternative diagnosis). Sixty-eight patients were included; 47 were classified as NC, 8 as PC, and 13 as probable nocardiosis. PCR results were negative for 35/47 NC patients (74%). For the 12 NC patients with positive PCR results, the PCR assay had been performed with respiratory samples. These NC patients had chronic bronchopulmonary disease more frequently than did the NC patients with negative PCR results (8/12 patients [67%] versus 11/35 patients [31%]; P = 0.044). PCR results were positive for 7/8 PC patients (88%). There were 13 cases of probable nocardiosis, diagnosed solely using the PCR results; 9 of those patients (69%) had lung involvement (consolidation or nodule). Nocardia PCR testing had a specificity of 74% and a sensitivity of 88% for the diagnosis of nocardiosis. Nocardia PCR testing may be helpful for the diagnosis of nocardiosis in immunocompromised patients but interpretation of PCR results from respiratory samples is difficult, because the PCR assay may also detect colonization. Copyright © 2018 American Society for Microbiology.

  16. A Multidisciplinary Delphi Consensus-Based Checklist to Define Clinical Documentation Tools for Both Routine and Research Purposes

    Directory of Open Access Journals (Sweden)

    Cecilia Veraar

    2018-01-01

    Full Text Available Background: To the best of our knowledge, a strategic approach to define the contents of structured clinical documentation tools for both clinical routine patient care and research purposes has not been reported so far, although electronic health record will become more and more structured and detailed in the future. Objective: To achieve an interdisciplinary consensus on a checklist to be considered for the preparation of disease- and situation-specific clinical documentation tools. Methods: A 2-round Delphi consensus-based process was conducted both with 19 physicians of different disciplines and 14 students from Austria, Switzerland, and Germany. Agreement was defined as 80% or more positive votes of the participants. Results: The participants agreed that a working group should be set up for the development of structured disease- or situation-specific documentation tools (97% agreement. The final checklist included 4 recommendations concerning the setup of the working group, 12 content-related recommendations, and 3 general and technical recommendations (mean agreement [standard deviation] = 97.4% [4.0%], ranging from 84.2% to 100.0%. Discussion and Conclusion: In the future, disease- and situation-specific structured documentation tools will provide an important bridge between registries and electronic health records. Clinical documentation tools defined according to this Delphi consensus-based checklist will provide data for registries while serving as high-quality data acquisition tools in routine clinical care.

  17. Differentiation of herpes simplex virus types 1 and 2 in clinical samples by a real-time taqman PCR assay.

    Science.gov (United States)

    Corey, Lawrence; Huang, Meei-Li; Selke, Stacy; Wald, Anna

    2005-07-01

    While the clinical manifestations of HSV-1 and -2 overlap, the site of CNS infection, complications, response to antivirals, frequency of antiviral resistance, and reactivation rate on mucosal surfaces varies between HSV-1 and -2. Detection of HSV DNA by PCR has been shown to be the most sensitive method for detecting HSV in clinical samples. As such, we developed a PCR-based assay to accurately distinguish HSV-1 from HSV-2. Our initial studies indicated the assay using type specific primers was slightly less efficient for detecting HSV-1 and -2 DNA than the high throughput quantitative PCR assay we utilize that employs type common primers to gB. We subsequently evaluated the type specific assay on 3,131 specimens that had HSV DNA detected in the type common PCR assay. The typing results of these specimens were compared with the monoclonal antibody staining results of culture isolates collected from the same patients at the same time, and the HSV serologic status of the patient. The typing assay accurately identified both HSV-1 and -2 with a specificity of >99.5% and was significantly more sensitive than typing by culture and subsequent monoclonal antibody assays. Complete concordance was seen between the typing assay and HSV serologic status of the patient. Dual (HSV-1 and -2) infection in clinical samples was recognized in 2.6% of clinical samples using the new typing assay. This assay, when used in combination with the type common assay, can now accurately type almost all mucosal and visceral HSV isolates by molecular techniques. Copyright (c) 2005 Wiley-Liss, Inc.

  18. Clinical utility of an automated immunochemiluminometric thyroglobulin assay in differentiated thyroid carcinoma

    NARCIS (Netherlands)

    Persoon, ACM; Van den Ouweland, JMW; Wilde, J; Kema, IP; Wolffenbuttel, BHR; Links, TP

    Background: Thyroglobulin (Tg) measurements are important in the follow-up of patients with differentiated thyroid carcinoma (DTC). We evaluated the analytical and clinical performance of a new automated immunochemiluminometric assay for Tg (Tg-ICMA; Nichols Advantage Tg; Nichols Institute

  19. Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  20. Rivaroxaban for venous thromboembolism prevention after major orthopedic surgery: translating trial data into routine clinical practice

    Directory of Open Access Journals (Sweden)

    Beyer-Westendorf J

    2017-01-01

    Full Text Available Jan Beyer-Westendorf,1 Patrick Mouret,2 Alexander GG Turpie3 1Thrombosis Research and Angiology, Dresden University Clinic, Dresden, Germany; 2Orthopedic Clinic, Klinikum Frankfurt Höchst GmbH, Frankfurt, Germany; 3Department of Medicine, General Division, Hamilton Health Sciences, Hamilton, ON, Canada Abstract: An established standard of care for the prevention of venous thromboembolism after major orthopedic surgery has been subcutaneous low-molecular-weight heparin. The non-vitamin K antagonist oral anticoagulant rivaroxaban has demonstrated superior efficacy and similar safety to all tested regimens of enoxaparin in large Phase III clinical studies of venous thromboembolism prevention after elective hip and knee arthroplasty. Despite regulatory approval of rivaroxaban for this indication, concerns remain among physicians regarding its optimal and effective use in routine clinical practice. Real-life studies, such as XAMOS and ORTHO-TEP, are providing physicians with more information on the routine use of rivaroxaban for venous thromboembolism prevention after orthopedic surgery, helping to establish its safety and effectiveness in everyday clinical care. Among the most important issues are the risk of bleeding complications, wound healing, timing of first dose, impact of type of anesthesia on thromboprophylaxis effectiveness, patient comorbidities and comedication use, periprocedural management, associated costs, and clinical outcomes in trauma-related fractures. Many of these issues are difficult to study in randomized, double-blind, Phase III trials, and can be assessed more readily using real-life data. In particular, real-life or noninterventional studies lack many of the strict inclusion and exclusion criteria associated with Phase III trials and involve unselected patients who often present with significant comorbidities or comedication use. Keywords: anticoagulants, arthroplasty, orthopedics, rivaroxaban, thrombosis

  1. Clinical utility of the PCA3 urine assay in European men scheduled for repeat biopsy.

    NARCIS (Netherlands)

    Haese, A.; Taille, A. De La; Poppel, H. van; Marberger, M.; Stenzl, A.; Mulders, P.F.A.; Huland, H.; Abbou, C.C.; Remzi, M.; Tinzl, M.; Feyerabend, S.; Stillebroer, A.B.; Gils, M.P.M.Q.; Schalken, J.A.

    2008-01-01

    BACKGROUND: The Prostate CAncer gene 3 (PCA3) assay has shown promise as an aid in prostate cancer (pCA) diagnosis in identifying men with a high probability of a positive (repeat) biopsy. OBJECTIVE: This study evaluated the clinical utility of the PROGENSA PCA3 assay. DESIGN, SETTING, AND

  2. Development of a new microtiter plate format for clinically relevant assays.

    Science.gov (United States)

    Piletska, Elena V; Piletsky, Stanislav S; Whitcombe, Michael J; Chianella, Iva; Piletsky, Sergey A

    2012-02-21

    A new format for the microtiter plate-based assays was proposed. The novelty involves the use of disk-shaped inserts for immobilization of biological and chemical reagents. The internal opening of the disks allows measurements of the reactions by standard microtiter plate readers without any additional steps involving liquid handling. Ideally the plate end-users just have to add the sample and take the measurement without any need of multiple reagent additions or transfer of the liquid to a different plate. The novel assay format also allows handling of reagents which are not soluble in an aqueous environment. As a proof of concept we describe here several model reactions which are compatible with microtiter plate format, such as monitoring enzymatic reactions catalyzed by glucose oxidase (GOx) and urease, measurements of proteins by BCA assay, analysis of pH, and concentration of antioxidants. The "mix and match" approach in the disk-shape format allows multiplexing and could be particularly useful for high throughput screening. One of the potential application areas for this novel assay format could be in a multianalyte system for measurement of clinically relevant analytes in primary care.

  3. Establishment and clinical application of immunoradiometric assay for human growth hormone in serum

    International Nuclear Information System (INIS)

    Ji Jinfeng; Wu Congyuan; Niu Zhanpo; Zhang Kui; Song Ailing; Deng Jieying; Shi Mifan

    1992-01-01

    An immunoradiometric assay (IRMA) for human growth hormone (hGH) in serum is developed based on two high specific monoclonal antibodies against hGh. It can specifically detect the levels of serum bioactive hGh and had no cross-reaction with human prolactin (hPRL) and hGh oligmeric forms. The sensitivity was 0.2 ng/ml and the recovery for different concentrations of hGh was 92.0% ∼ 103.2%. The coefficients of variation for intra and inter-assay were<9.1% and <14.2%, respectively. Integral analysis of the results of RIA and IRMA with the patients' clinical manifestations revealed that hGh IRMA is better than hGh RIA in reflecting the clinical states of different acromegalic patients

  4. Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

    Science.gov (United States)

    Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.

    2006-01-01

    Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529

  5. Clinical outcomes and cost effectiveness of accelerated diagnostic protocol in a chest pain center compared with routine care of patients with chest pain.

    Science.gov (United States)

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (pdiagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (pdiagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (pdiagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), pdiagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.

  6. Use of global assays to understand clinical phenotype in congenital factor VII deficiency.

    Science.gov (United States)

    Greene, L A; Goldenberg, N A; Simpson, M L; Villalobos-Menuey, E; Bombardier, C; Acharya, S S; Santiago-Borrero, P J; Cambara, A; DiMichele, D M

    2013-09-01

    Congenital factor VII (FVII) deficiency is characterized by genotypic variability and phenotypic heterogeneity. Traditional screening and factor assays are unable to reliably predict clinical bleeding phenotype and guide haemorrhage prevention strategy. Global assays of coagulation and fibrinolysis may better characterize overall haemostatic balance and aid in haemorrhagic risk assessment. We evaluated the ability of novel global assays to better understand clinical bleeding severity in congenital FVII deficiency. Subjects underwent central determination of factor VII activity (FVII:C) as well as clot formation and lysis (CloFAL) and simultaneous thrombin and plasmin generation (STP) global assay analysis. A bleeding score was assigned to each subject through medical chart review. Global assay parameters were analysed with respect to bleeding score and FVII:C. Subgroup analyses were performed on paediatric subjects and subjects with FVII ≥ 1 IU dL(-1). CloFAL fibrinolytic index (FI2 ) inversely correlated with FVII:C while CloFAL maximum amplitude (MA) and STP maximum velocity of thrombin generation (VT max) varied directly with FVII:C. CloFAL FI2 directly correlated with bleeding score among subjects in both the total cohort and paediatric subcohort, but not among subjects with FVII ≥ 1 IU dL(-1) . Among subjects with FVII ≥ 1 IU dL(-1), STP time to maximum velocity of thrombin generation and time to maximum velocity of plasmin generation inversely correlated with bleeding score. These preliminary findings suggest a novel potential link between a hyperfibrinolytic state in bleeding severity and congenital FVII deficiency, an observation that should be further explored. © 2013 John Wiley & Sons Ltd.

  7. Routine chest X-ray in the allergy clinic

    International Nuclear Information System (INIS)

    Garcia-Barredo, M.R.; Usamentiaga, E.; Fidalgo, I.

    1997-01-01

    To determine whether routine chest X-ray is indicated in allergy patients when there is no evidence of cardiopulmonary involvement. A retrospective study to analyze the indications and radiologic findings in 515 consecutive patients who underwent chest X-ray: Positive findings were considered to be any radiological sing that led to the performance of additional diagnostic measures or a change in the therapeutic management of the patient. Positive radiologic findings were observed in 39 cases (7.59%). Only two patients (0.38%) were diagnosed as having diseases that were susceptible to proper treatment. In one of them (0.19%), the failure to perform chest X-ray would have impeded the introduction of proper treatment. We do not recommend carrying out routine chest X-ray in this patient population. (Author) 7 refs

  8. Evaluation of a polymerase chain reaction assay for pathogen detection in septic patients under routine condition: an observational study.

    Directory of Open Access Journals (Sweden)

    Frank Bloos

    Full Text Available BACKGROUND: Treatment of septic shock relies on appropriate antimicrobial therapy. Current culture based methods deliver final results after days, which may delay potentially lifesaving adjustments in antimicrobial therapy. This study was undertaken to compare PCR with blood culture results under routine conditions regarding 1. impact on antimicrobial therapy, and 2. time to result, in patients with presumed sepsis. METHODOLOGY/PRINCIPAL FINDINGS: This was an observational study in a 50 beds ICU of a university hospital. In 245 patients with suspected sepsis, 311 concomitant blood cultures and blood for multiplex PCR (VYOO(® were obtained. 45 of 311 blood cultures (14.5% and 94 of 311 PCRs (30.1% were positive. However, blood culture or microbiological sampling from the presumed site of infection rarely confirmed PCR results and vice versa. Median time to positivity and interquartile range were 24.2 (18.0, 27.5 hours for the PCR and 68 (52.2, 88.5 hours for BC (p<0.01. PCR median time to result was dependent on technician availability (53.5 hours on Saturdays, 7.2 hours under optimal logistic conditions. PCR results showed good correlation with procalcitonin (p<0.001. In 34% of patients with positive PCRs antimicrobial therapy was considered inadequate according to assessment of clinical arbitrators including 5 patients with vancomycin-resistant enterococci (VRE, 3 cases with multiresistant staphylococci, and 4 patients with fungi. CONCLUSIONS: The results of this observational study support the hypothesis that PCR results are available faster, are more frequently positive, and may result in earlier adjustment of antimicrobial therapy. However, shorter time to result can only be fully exploited when the laboratory is adequately staffed for a 24 hour/7 day service, or when point of care/automated assay systems become available.

  9. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    Science.gov (United States)

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  10. Multiplexing a high-throughput liability assay to leverage efficiencies.

    Science.gov (United States)

    Herbst, John; Anthony, Monique; Stewart, Jeremy; Connors, David; Chen, Taosheng; Banks, Martyn; Petrillo, Edward W; Agler, Michele

    2009-06-01

    In order to identify potential cytochrome P-450 3A4 (drug-metabolizing enzyme) inducers at an early stage of the drug discovery process, a cell-based transactivation high-throughput luciferase reporter assay for the human pregnane X receptor (PXR) in HepG2 cells has been implemented and multiplexed with a viability end point for data interpretation, as part of a Lead Profiling portfolio of assays. As a routine part of Lead Profiling operations, assays are periodically evaluated for utility as well as for potential improvements in technology or process. We used a recent evaluation of our PXR-transactivation assay as a model for the application of Lean Thinking-based process analysis to lab-bench assay optimization and automation. This resulted in the development of a 384-well multiplexed homogeneous assay simultaneously detecting PXR transactivation and HepG2 cell cytotoxicity. In order to multiplex fluorescent and luminescent read-outs, modifications to each assay were necessary, which included optimization of multiple assay parameters such as cell density, plate type, and reagent concentrations. Subsequently, a set of compounds including known cytotoxic compounds and PXR inducers were used to validate the multiplexed assay. Results from the multiplexed assay correlate well with those from the singleplexed assay formats measuring PXR transactivation and viability separately. Implementation of the multiplexed assay for routine compound profiling provides improved data quality, sample conservation, cost savings, and resource efficiencies.

  11. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  12. Two-step versus one-step FT4 assays in heparin treated patients and non-thyroidal illness

    International Nuclear Information System (INIS)

    Reiners, C.; Bieler, G.; Ertl, G.; Gloss, H.; Boerner, W.

    1985-01-01

    The primary intention of this study is to inform the clinician about the direction and the order of magnitude of possible disturbances of different FT 4 parameters under the condition mentioned last, which is not uncommon in daily routine. No single FT 4 -RIA proved be valid in severe NTI. There is the risk to misinterprete hyperthyroidism as euthyroidism with 1step assays and the possibility to classify euthyroid patients falsely as hyperthyroid with 2step assays. In relation to this problem, the sometimes lowered FT 4 values by 1step methods are clinically not so important. It has to be established, wether TSH assays of high sensitivity are able to overcome some of the difficulties with determinations of peripheral thyroid hormones in NTI. (orig./MG)

  13. Evaluation of Commercial Diagnostic Assays for the Specific Detection of Avian Influenza A (H7N9) Virus RNA Using a Quality-Control Panel and Clinical Specimens in China

    Science.gov (United States)

    Chen, Suhong; Wang, Dayan; Li, Changgui; Wu, Xing; Li, Lili; Bai, Dongting; Zhang, Chuntao; Wang, Junzhi

    2015-01-01

    A novel avian influenza A H7N9-subtype virus emerged in China in 2013 and threatened global public health. Commercial kits that specifically detect avian influenza A (H7N9) virus RNA are urgently required to prepare for the emergence and potential pandemic of this novel influenza virus. The safety and effectiveness of three commercial molecular diagnostic assays were evaluated using a quality-control panel and clinical specimens collected from over 90 patients with confirmed avian influenza A (H7N9) virus infections. The analytical performance evaluation showed that diverse influenza H7N9 viruses can be detected with high within- and between-lot reproducibility and without cross-reactivity to other influenza viruses (H1N1 pdm09, seasonal H1N1, H3N2, H5N1 and influenza B). The detection limit of all the commercial assays was 2.83 Log10 copies/μl [0.7 Log10TCID50/mL of avian influenza A (H7N9) virus strain A/Zhejiang/DTID-ZJU01/2013], which is comparable to the method recommended by the World Health Organization (WHO). In addition, using a WHO-Chinese National Influenza Center (CNIC) method as a reference for clinical evaluation, positive agreement of more than 98% was determined for all of the commercial kits, while negative agreement of more than 99% was observed. In conclusion, our findings provide comprehensive evidence for the high performance of three commercial diagnostic assays and suggest the application of these assays as rapid and effective diagnostic tools for avian influenza A (H7N9) virus in the routine clinical practice of medical laboratories. PMID:26361351

  14. Implementing Functional Preoperative Mapping in the Clinical Routine of a Neurosurgical Department: Technical Note.

    Science.gov (United States)

    Sollmann, Nico; Meyer, Bernhard; Krieg, Sandro M

    2017-07-01

    Navigated transcranial magnetic stimulation (nTMS) is increasingly being used for mapping of various brain functions and in nTMS-based tractography in neurosurgical departments worldwide. When a department begins using nTMS data in the clinical workflow, smooth integration into the hospital's existing infrastructure is mandatory. Standardized approaches for this beyond the mapping or tractography procedures themselves have not yet been described. To create an effective workflow for neurosurgical nTMS mapping, we present the findings of our 7 years of experience and progressive integration into the clinical routine. After indication for mapping is made, the workflow starts with patient admission and includes all preoperative steps until tumor resection. Importantly, only standard software and devices were used, enabling new centers to easily integrate data derived from nTMS mapping and nTMS-based tractography into their hospital's infrastructure. Registration of the patient, appointment planning, and documentation of results of the nTMS procedures within the hospital information system (HIS) can be achieved by a novel tailored software mask. As another important part of the workflow, nTMS data are imported into the picture archiving and communication system (PACS) via PACS integrator software. In addition, for surgical planning including nTMS-based tractography, nTMS data can be effectively included in surgical neuronavigation software. Optimized integration of nTMS data can be achieved using a standardized workflow. The seamless integration and availability of nTMS data are crucial to the acceptance of these data in the clinical routine. This optimized workflow can serve as a guide for centers beginning to use nTMS data in patient care. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Newborn Congenital Cytomegalovirus Screening Based on Clinical Manifestations and Evaluation of DNA-based Assays for In Vitro Diagnostics.

    Science.gov (United States)

    Fujii, Tomoyuki; Oka, Akira; Morioka, Ichiro; Moriuchi, Hiroyuki; Koyano, Shin; Yamada, Hideto; Saito, Shigeru; Sameshima, Hiroshi; Nagamatsu, Takeshi; Tsuchida, Shinya; Inoue, Naoki

    2017-10-01

    To establish a strategy for congenital cytomegalovirus (cCMV) screening and to establish confirmatory assays approved as in vitro diagnostics by the regulatory authorities, we evaluated the clinical risks and performance of diagnostic assays developed by commercial companies, since cCMV infection has significant clinical consequences. Newborns with clinical manifestations considered to be consequences of cCMV infection (n = 575) were screened for the presence of cytomegalovirus (CMV) DNA in urine specimens collected onto filter paper placed in their diapers using the polymerase chain reaction-based assay reported previously. Liquid urine specimens were obtained from all of 20 CMV-positive newborns and 107 of the CMV-negative newborns identified in the screening. We used these 127 specimens, as well as 12 from cCMV cases identified in a previous study and 41 from healthy newborns, to compare the performance of 2 commercial assays and 1 in-house assay. The risk-based screening allowed the identification of cCMV cases at least 10-fold more efficiently than our previous universal screening, although there appears to be a limit to the identification of asymptomatically infected newborns. Although CMV-specific IgM during pregnancy was found frequently in mothers of cCMV newborns, CMV-IgM alone is not an effective diagnostic marker. The urine-filter-based assay and the 3 diagnostic assays yielded identical results. Although risk-based and universal newborn screening strategies for cCMV infection each have their respective advantages and disadvantages, urine-filter-based assay followed by confirmatory in vitro diagnostics assays is able to identify cCMV cases efficiently.

  16. The enhanced pneumococcal LAMP assay: a clinical tool for the diagnosis of meningitis due to Streptococcus pneumoniae.

    Directory of Open Access Journals (Sweden)

    Dong Wook Kim

    Full Text Available BACKGROUND: Streptococcus pneumoniae is a leading cause of invasive bacterial disease in developed and developing countries. We studied the loop-mediated isothermal amplification (LAMP technique to assess its suitability for detecting S. pneumoniae nucleic acid in cerebrospinal fluid (CSF. METHODOLOGY/PRINCIPAL FINDINGS: We established an improved LAMP assay targeting the lytA gene (Streptococcus pneumoniae [Sp] LAMP. The analytical specificity of the primers was validated by using 32 reference strains (10 Streptococcus and seven non-Streptococcus species plus 25 clinical alpha-hemolytic streptococcal strains, including four S. pneumoniae strains and 21 other strains (3 S. oralis, 17 S. mitis, and one Streptococcus species harboring virulence factor-encoding genes (lytA or ply. Within 30 minutes, the assay could detect as few as 10 copies of both purified DNA and spiked CSF specimens with greater sensitivity than conventional polymerase chain reaction (PCR. The linear determination range for this assay is 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the clinical sensitivity and specificity of the Sp LAMP assay using 106 randomly selected CSF specimens from children with suspected meningitis in Korea, China and Vietnam. For comparison, CSF specimens were also tested against conventional PCR and culture tests. The detection rate of the LAMP method was substantially higher than the rates of PCR and culture tests. In this small sample, relative to the LAMP assay, the clinical sensitivity of PCR and culture tests was 54.5% and 33.3%, respectively, while clinical specificity of the two tests was 100%. CONCLUSIONS/SIGNIFICANCE: Compared to PCR, Sp LAMP detected S. pneumoniae with higher analytical and clinical sensitivity. This specific and sensitive LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.

  17. Pre-Clinical Testing of Real-Time PCR Assays for Diarrheal Disease Agents of Genera Escherichia and Shigella

    Science.gov (United States)

    2014-05-16

    FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA May 16, 2014 Reporting Period: October 1, 2010 to September 30, 2013...10-2010 - 30-09-2013 PRE-CLINICAL TESTING OF REAL-TIME PCR ASSAYS FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA ...Texas (MOA 2007 - 2013. Agreement No.: DODI 4000.19; AFI 25-201). Pre-clinical test results qualify ETEC and Shigella real-time PCR assays as lead

  18. Enzyme activity assay of glycoprotein enzymes based on a boronate affinity molecularly imprinted 96-well microplate.

    Science.gov (United States)

    Bi, Xiaodong; Liu, Zhen

    2014-12-16

    Enzyme activity assay is an important method in clinical diagnostics. However, conventional enzyme activity assay suffers from apparent interference from the sample matrix. Herein, we present a new format of enzyme activity assay that can effectively eliminate the effects of the sample matrix. The key is a 96-well microplate modified with molecularly imprinted polymer (MIP) prepared according to a newly proposed method called boronate affinity-based oriented surface imprinting. Alkaline phosphatase (ALP), a glycoprotein enzyme that has been routinely used as an indicator for several diseases in clinical tests, was taken as a representative target enzyme. The prepared MIP exhibited strong affinity toward the template enzyme (with a dissociation constant of 10(-10) M) as well as superb tolerance for interference. Thus, the enzyme molecules in a complicated sample matrix could be specifically captured and cleaned up for enzyme activity assay, which eliminated the interference from the sample matrix. On the other hand, because the boronate affinity MIP could well retain the enzymatic activity of glycoprotein enzymes, the enzyme captured by the MIP was directly used for activity assay. Thus, additional assay time and possible enzyme or activity loss due to an enzyme release step required by other methods were avoided. Assay of ALP in human serum was successfully demonstrated, suggesting a promising prospect of the proposed method in real-world applications.

  19. Development of a surrogate angiogenic potency assay for clinical-grade stem cell production.

    Science.gov (United States)

    Lehman, Nicholas; Cutrone, Rochelle; Raber, Amy; Perry, Robert; Van't Hof, Wouter; Deans, Robert; Ting, Anthony E; Woda, Juliana

    2012-09-01

    Clinical results from acute myocardial infarction (AMI) patients treated with MultiStem®, a large-scale expanded adherent multipotent progenitor cell population (MAPC), have demonstrated a strong safety and benefit profile for these cells. The mechanism of benefit with MAPC treatment is a result, in part, of its ability to induce neovascularization through trophic support. Production of clinical-grade stem cell products requires the development of lot-release criteria based on potency assays that directly reflect the fundamental mechanistic pathway underlying the therapeutic response to verify manufacturing process consistency and product potency. Using an in vitro endothelial tube formation assay, a potency assay has been developed that reflects MAPC pro-angiogenic activity. Serum-free conditioned media collected from MAPC culture induced endothelial tube formation. A proteomic survey of angiogenic factors produced by the cells in vitro revealed candidate factors linked to angiogenic potency. Three cytokines, chemokine (C-X-C motif) ligand 5 (CXCL5), interleukin 8 (IL-8) and vascular endothelial growth factor (VEGF), were required for this angiogenic activity. Depletion of any of these factors from the media prevented tube formation, while adding back increasing amounts of these cytokines into the depleted serum-free conditioned media established the lower limits of each of the cytokines required to induce angiogenesis. A necessary threshold of angiogenic factor expression was established using an in vitro angiogenesis assay. By correlating the levels of the cytokines required to induce tube formation in vitro with levels of the factors found in the spent media from manufacturing production runs, detection of these factors was identified as a surrogate potency assay with defined pass/fail criteria.

  20. COPD management: role of symptom assessment in routine clinical practice

    Directory of Open Access Journals (Sweden)

    van der Molen T

    2013-10-01

    Full Text Available Thys van der Molen,1,2 Marc Miravitlles,3 Janwillem WH Kocks1,21Department of General Practice, 2GRIAC (Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands; 3Pneumology Department, Hospital Universitari Vall d'Hebron, Biomedical Research Networking Centre in Respiratory Diseases (CIBERES, Barcelona, SpainAbstract: Patients with chronic obstructive pulmonary disease (COPD present with a variety of symptoms that significantly impair health-related quality of life. Despite this, COPD treatment and its management are mainly based on lung function assessments. There is increasing evidence that conventional lung function measures alone do not correlate well with COPD symptoms and their associated impact on patients' everyday lives. Instead, symptoms should be assessed routinely, preferably by using patient-centered questionnaires that provide a more accurate guide to the actual burden of COPD. Numerous questionnaires have been developed in an attempt to find a simple and reliable tool to use in everyday clinical practice. In this paper, we review three such patient-reported questionnaires recommended by the latest Global Initiative for Chronic Obstructive Lung Disease guidelines, ie, the modified Medical Research Council questionnaire, the clinical COPD questionnaire, and the COPD Assessment Test, as well as other symptom-specific questionnaires that are currently being developed.Keywords: chronic obstructive pulmonary disease, symptoms, questionnaires

  1. Developing the public health role of a front line clinical service: integrating stop smoking advice into routine podiatry services.

    Science.gov (United States)

    Gray, Jackie; Eden, Gary; Williams, Maria

    2007-06-01

    Although smoking is a major public health problem, many clinicians do not routinely provide evidence-based health improvement advice to smokers to help them to quit. Plan, Do, Study, Act (PDSA) cycle methodology was used to design and implement a service development so that health improvement advice for smokers featured in all podiatry consultations provided by a Primary Care Trust in North East England. IT systems were developed to record the number and proportion of patients for whom smoking status was assessed, and the number and proportion of smokers who were given advice to quit and referred for specialist support. A questionnaire to staff explored their perceptions of the development on their clinics and consultations. During a 6-month period, smoking status was recorded for all 8831 (100%) patients attending podiatry clinics; 83% of smokers were given brief advice to quit; 7% of smokers were given help to access specialist stop smoking support services. Improvements were introduced within existing budgets and did not prolong clinics. It is straightforward and inexpensive to develop clinical services so that public health guidance is routinely implemented. More widespread implementation of similar service developments could lead to national improvements in public health.

  2. Assay of free urinary cortisol with inverted phase liquid chromatography and radiocompetition

    International Nuclear Information System (INIS)

    Franck, C.; Patricot, M.C.; Mathian, B.; Revol, A.

    1984-01-01

    The authors present an assay method for free urinary cortisol using inverted phase liquid chromatography for purification and radiocompetition for the assay. The usual values for adult men and women were established. The results of 150 routine assays were compared with those of 17 OHCS revealing the value of this assay [fr

  3. A mixed methods approach to adapting health-related quality of life measures for use in routine oncology clinical practice.

    Science.gov (United States)

    Harley, Clare; Takeuchi, Elena; Taylor, Sally; Keding, Ada; Absolom, Kate; Brown, Julia; Velikova, Galina

    2012-04-01

    The current study reviewed and adapted existing health-related quality of life (HRQoL) instruments for use in routine clinical practice delivering outpatient chemotherapy for colorectal, breast and gynaecological cancers. 564 (288 gynaecological, 208 breast and 68 colorectal) outpatient consultations of 141 patients were audio-recorded and analysed to identify discussed issues. Issues were ranked from most to least commonly discussed within each disease group. Existing HRQoL instruments were evaluated against these lists and best fitting items entered into cancer-specific item banks. Item banks were evaluated during semi-structured interviews by twenty-one oncologists (13 consultants and 8 specialist registrars), four clinical nurse specialists and thirty patients, from breast, gynaecological and colorectal cancer practices. Pilot questionnaires were completed by 448 (145 breast, 148 gynaecological and 155 colorectal) patients attending outpatient clinics. Item selection and scale reliability was explored using descriptive data and psychometric methods alongside qualitative patient and clinician ratings. Each questionnaire includes five physical and three psychosocial function scales each with good internal consistency reliability (α > 0.70) plus disease-specific individual-symptom items identified as useful in clinical practice. Three cancer-specific health-related quality of life measures were developed for use in routine clinical practice. Initial analyses suggest good clinical utility and acceptable psychometric properties for the new instruments.

  4. Multicenter Clinical Evaluation of the Alere i Respiratory Syncytial Virus Isothermal Nucleic Acid Amplification Assay.

    Science.gov (United States)

    Hassan, Ferdaus; Hays, Lindsay M; Bonner, Aleta; Bradford, Bradley J; Franklin, Ruffin; Hendry, Phyllis; Kaminetsky, Jed; Vaughn, Michael; Cieslak, Kristin; Moffatt, Mary E; Selvarangan, Rangaraj

    2018-03-01

    The Alere i respiratory syncytial virus (RSV) assay is an isothermal nucleic acid amplification test capable of detecting RSV directly from respiratory specimens, with results being available in ≤13 min after test initiation. The objective of this study was to evaluate the performance characteristics of the Alere i RSV assay in a point-of-care setting by using direct nasopharyngeal (NP) swab specimens (direct NP) and nasopharyngeal swab specimens eluted and transported in viral transport medium (VTM NP). The study was a prospective, multicenter, clinical trial conducted at 9 sites across the United States to evaluate the clinical performance of the Alere i RSV assay with respiratory specimens obtained from both children (age, 60 years). The performance of the Alere i RSV assay was compared with that of the reference method, the Prodesse ProFlu+ real-time reverse transcriptase PCR (RT-PCR) assay. All specimens with discrepant test results were tested further by a second FDA-cleared PCR assay (the Verigene respiratory virus plus nucleic acid test; Luminex Inc., TX). A total of 554 subjects with signs and symptoms of respiratory infections were enrolled, and respiratory samples were collected in this study. In comparison with the ProFlu+ real-time RT-PCR, the overall sensitivity and specificity of Alere i RSV assay for the detection of RSV were 98.6% (95% confidence interval [CI], 94.4 to 99.7%) and 98.0% (95% CI, 95.8 to 99.1%), respectively, for direct NP and 98.6% (95% CI, 94.4 to 99.7%) and 97.8% (95% CI, 95.5 to 98.9%), respectively, for VTM NP. The Alere i RSV is a highly sensitive and specific molecular assay ideal for rapid RSV detection in patients in the point-of-care setting due to its minimal hands-on time and rapid result availability. Copyright © 2018 American Society for Microbiology.

  5. Routine Responses to Disruption of Routines

    Science.gov (United States)

    Guha, Mahua

    2015-01-01

    "Organisational routines" is a widely studied research area. However, there is a dearth of research on disruption of routines. The few studies on disruption of routines discussed problem-solving activities that are carried out in response to disruption. In contrast, this study develops a theory of "solution routines" that are a…

  6. Arterial Destiffening in Previously Untreated Mild Hypertensives After 1 Year of Routine Clinical Management.

    Science.gov (United States)

    Rodilla, Enrique; Millasseau, Sandrine; Costa, Jose Antonio; Pascual, Jose Maria

    2017-05-01

    Arterial stiffness, measured with pulse wave velocity (PWV), is now classified as a marker of target organ damage (TOD) alongside left ventricular hypertrophy and moderately increased albuminuria. Interventional studies on treated hypertensive patients have shown that PWV could be improved. Our aim was to assess changes in arterial stiffness after 1 year of routine clinical practice in never-treated hypertensive patients. We studied 356 never-treated patients with suspected hypertension. After standard clinical assessment during which presence of TOD was evaluated, hypertension diagnosis was confirmed in 231 subjects who subsequently received standard routine care. Both hypertensive and the 125 controls came back for a follow-up visit after 1 year. Hypertensive patients were slightly older (46 ± 12 vs. 50 ± 12 years, P < 0.001), with higher mean arterial pressure (MAP)-adjusted PWV compared to controls (8.6 ± 2.0 vs. 8.0 ± 1.7 m/s, P < 0.001) and 47% of them presented 1 or more TOD. After 1 year of treatment, MAP was similar in both groups (94.9 vs. 96.2 mm Hg; P = ns), but adjusted PWV remained significantly higher in the hypertensive patients (7.8 ± 1.4 vs. 8.3 ± 1.7 m/s, P = 0.004). The prevalence of elevated PWV was reduced from 20% to 12%. All antihypertensive drugs achieved the same blood pressure (BP) and PWV reduction with the exception of vasodilating beta-blockers which gave slightly better results probably due to heart rate reduction. BP reduction in newly diagnosed hypertensive patients improves arterial stiffness within a year of real-life clinical practice. Patients with the highest PWV and the largest reduction of BP "destiffened" the most whatever antihypertensive class was used. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Development and accuracy of quantitative real-time polymerase chain reaction assays for detection and quantification of enterotoxigenic Escherichia coli (ETEC) heat labile and heat stable toxin genes in travelers' diarrhea samples.

    Science.gov (United States)

    Youmans, Bonnie P; Ajami, Nadim J; Jiang, Zhi-Dong; Petrosino, Joseph F; DuPont, Herbert L; Highlander, Sarah K

    2014-01-01

    Enterotoxigenic Escherichia coli (ETEC), the leading bacterial pathogen of travelers' diarrhea, is routinely detected by an established DNA hybridization protocol that is neither sensitive nor quantitative. Quantitative real-time polymerase chain reaction (qPCR) assays that detect the ETEC toxin genes eltA, sta1, and sta2 in clinical stool samples were developed and tested using donor stool inoculated with known quantities of ETEC bacteria. The sensitivity of the qPCR assays is 89%, compared with 22% for the DNA hybridization assay, and the limits of detection are 10,000-fold lower than the DNA hybridization assays performed in parallel. Ninety-three clinical stool samples, previously characterized by DNA hybridization, were tested using the new ETEC qPCR assays. Discordant toxin profiles were observed for 22 samples, notably, four samples originally typed as ETEC negative were ETEC positive. The qPCR assays are unique in their sensitivity and ability to quantify the three toxin genes in clinical stool samples.

  8. Artificial neural networks to predict presence of significant pathology in patients presenting to routine colorectal clinics.

    Science.gov (United States)

    Maslekar, S; Gardiner, A B; Monson, J R T; Duthie, G S

    2010-12-01

    Artificial neural networks (ANNs) are computer programs used to identify complex relations within data. Routine predictions of presence of colorectal pathology based on population statistics have little meaning for individual patient. This results in large number of unnecessary lower gastrointestinal endoscopies (LGEs - colonoscopies and flexible sigmoidoscopies). We aimed to develop a neural network algorithm that can accurately predict presence of significant pathology in patients attending routine outpatient clinics for gastrointestinal symptoms. Ethics approval was obtained and the study was monitored according to International Committee on Harmonisation - Good Clinical Practice (ICH-GCP) standards. Three-hundred patients undergoing LGE prospectively completed a specifically developed questionnaire, which included 40 variables based on clinical symptoms, signs, past- and family history. Complete data sets of 100 patients were used to train the ANN; the remaining data was used for internal validation. The primary output used was positive finding on LGE, including polyps, cancer, diverticular disease or colitis. For external validation, the ANN was applied to data from 50 patients in primary care and also compared with the predictions of four clinicians. Clear correlation between actual data value and ANN predictions were found (r = 0.931; P = 0.0001). The predictive accuracy of ANN was 95% in training group and 90% (95% CI 84-96) in the internal validation set and this was significantly higher than the clinical accuracy (75%). ANN also showed high accuracy in the external validation group (89%). Artificial neural networks offer the possibility of personal prediction of outcome for individual patients presenting in clinics with colorectal symptoms, making it possible to make more appropriate requests for lower gastrointestinal endoscopy. © 2010 The Authors. Colorectal Disease © 2010 The Association of Coloproctology of Great Britain and Ireland.

  9. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia.

    Science.gov (United States)

    Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2011-09-01

    Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Two new automated, compared with two enzyme-linked immunosorbent, antimüllerian hormone assays.

    Science.gov (United States)

    Nelson, Scott M; Pastuszek, Ewa; Kloss, Grzegorz; Malinowska, Iwona; Liss, Joanna; Lukaszuk, Aron; Plociennik, Lukasz; Lukaszuk, Krzysztof

    2015-10-01

    To compare new automated antimüllerian hormone (AMH) assay performance characteristics from the new automated Elecsys AMH (Roche; Elecsys) and Access AMH (Beckman Coulter; Access) assays with the existing AMH Gen II ELISA (enzyme-linked immunosorbent assay; Gen II; Beckman Coulter) and AMH ELISA (Ansh Labs) assays. Prospective assay evaluation. University-affiliated clinical chemistry laboratory. Patients referred for serum AMH measurement (n = 83) before start of in vitro fertilization cycle between September 2014 and October 2014. None. Serum AMH concentration. Intra-assay coefficients of variation were low; Ansh ≤ 9.0%; Gen II ≤ 5.8%; Access ≤ 10.7%; and Elecsys ≤ 2.8%. The Passing-Bablok regression equations (pmol/L) were y (Access) = 0.128 + (0.781 × Gen II); and y (Access) = 0.302 + (0.742 x Ansh). For y (Elecys) = 0.087 + (0.729 x Gen II) and y (Elecys) = 0.253 + (0.688 x Ansh Labs). For y (Elecys) = 0.943 - (0.037 × Access). For all the assays, AMH exhibited a moderate positive correlation with AFC (r = 0.62-0.64); number of cumulus oocyte complexes (r = 0.60-0.64); and metaphase II oocytes (r = 0.48-0.50). Accuracy of pregnancy prediction, as determined by area under the receiver operating characteristic curve, was uniformly low for all assays (0.62-0.63). The novel automated assays exhibit strong concordance in calibration, but derived values are substantially lower than those obtained from pre-existing assays, with assay-specific interpretation required for routine clinical use. These results highlight the need for an international standard of measurement of AMH. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Assays for Qualification and Quality Stratification of Clinical Biospecimens Used in Research: A Technical Report from the ISBER Biospecimen Science Working Group.

    Science.gov (United States)

    Betsou, Fay; Bulla, Alexandre; Cho, Sang Yun; Clements, Judith; Chuaqui, Rodrigo; Coppola, Domenico; De Souza, Yvonne; De Wilde, Annemieke; Grizzle, William; Guadagni, Fiorella; Gunter, Elaine; Heil, Stacey; Hodgkinson, Verity; Kessler, Joseph; Kiehntopf, Michael; Kim, Hee Sung; Koppandi, Iren; Shea, Katheryn; Singh, Rajeev; Sobel, Marc; Somiari, Stella; Spyropoulos, Demetri; Stone, Mars; Tybring, Gunnel; Valyi-Nagy, Klara; Van den Eynden, Gert; Wadhwa, Lalita

    2016-10-01

    This technical report presents quality control (QC) assays that can be performed in order to qualify clinical biospecimens that have been biobanked for use in research. Some QC assays are specific to a disease area. Some QC assays are specific to a particular downstream analytical platform. When such a qualification is not possible, QC assays are presented that can be performed to stratify clinical biospecimens according to their biomolecular quality.

  12. Comparison of the genexpert enterovirus assay (GXEA) with real-time one step RT-PCR for the detection of enteroviral RNA in the cerebrospinal fluid of patients with meningitis.

    Science.gov (United States)

    Hong, JiYoung; Kim, Ahyoun; Hwang, Seoyeon; Cheon, Doo-Sung; Kim, Jong-Hyen; Lee, June-Woo; Park, Jae-Hak; Kang, Byunghak

    2015-02-13

    Enteroviruses (EVs) are the leading cause of aseptic meningitis worldwide. Detection of enteroviral RNA in clinical specimens has been demonstrated to improve the management of patient care, especially that of neonates and young children. To establish a sensitive and reliable assay for routine laboratory diagnosis, we compared the sensitivity and specificity of the GeneXpert Enterovirus Assay (GXEA) with that of the reverse transcription polymerase chain reaction (RT-PCR) based assay referred to as real-time one step RT-PCR (RTo-PCR). The sensitivity/specificity produced by GXEA and RTo-PCR were 100%/100% and 65%/100%, respectively. Both methods evaluated in this article can be used for detection of enterovirus in clinical specimens and these nucleic acid amplification methods are useful assays for the diagnosis of enteroviral infection.

  13. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  14. Broad-range (pan) Salmonella and Salmonella serotype typhi-specific real-time PCR assays: potential tools for the clinical microbiologist.

    Science.gov (United States)

    Farrell, John J; Doyle, Laura J; Addison, Rachel M; Reller, L Barth; Hall, Geraldine S; Procop, Gary W

    2005-03-01

    We describe broad-range salmonellae (ie, Salmonella) and Salmonella serotype Typhi-specific LightCycler (Roche Diagnostics, Indianapolis, IN) real-time polymerase chain reaction assays. We validated these with a battery of 280 bacteria, 108 of which were salmonellae representing 20 serotypes. In addition, 298 isolates from 170 clinical specimens that were suspected to possibly represent Salmonella were tested with the pan- Salmonella assay. Finally, the pan-Salmonella assay also was used to test DNA extracts from 101 archived, frozen stool specimens, 55 of which were culture-positive for salmonellae. Both assays were 100% sensitive and specific when cultured isolates of the battery were tested. The pan- Salmonella assay also characterized correctly all salmonellae on the primary isolation agar and was 96% sensitive (53/55) and 96% specific (49/51) when nucleic acid extracts from direct stool specimens were tested. These assays represent potential tools the clinical microbiologist could use to screen suspect isolates or stool specimens for Salmonella.

  15. A novel method for radioimmunoassay and its application to the assay of digoxin

    International Nuclear Information System (INIS)

    Lader, S.R.

    1977-01-01

    A novel radioimmunoassay method has been developed for digoxin which eliminates the need for centrifugation while retaining a short incubation time at ambient temperature. The apparatus used consists of a plastic reaction chamber containing a pad of absorbent material impregnated with solid phase antibody. A mixture of tracer and standard (or tracer and sample) is pipetted onto the antibody-containing pad and at the end of the thirty minute incubation period radioactivity remaining unbound to antibody is drawn through the pad into an absorbent filter by capillary attraction. The specificity, sensitivity, precision and accuracy of the method are described. Clinical evaluation of the method has been carried out in two laboratories in the United Kingdom and four in the United States of America. The consistency of performance of the new digoxin method as judged by precision and accuracy were quite striking compared with the wide variation in performance of routine in-house methods. Thus, results for between assay reproducibility show that C.V.'s for the novel method ranged from 9.6% to 15.5% while those for the routine assays ranged from 7% to 27,8%. The recovery of digoxin added to serum varied from 85% to 117% for the new method and from 88% to 164% with in-house methods. In a total of 640 clinical samples the results compared well with those obtained with established in-house procedures. (orig.) [de

  16. A triplex quantitative real-time PCR assay for differential detection of human adenovirus serotypes 2, 3 and 7.

    Science.gov (United States)

    Qiu, Fang-Zhou; Shen, Xin-Xin; Zhao, Meng-Chuan; Zhao, Li; Duan, Su-Xia; Chen, Chen; Qi, Ju-Ju; Li, Gui-Xia; Wang, Le; Feng, Zhi-Shan; Ma, Xue-Jun

    2018-05-02

    Human adenovirus (HAdV) serotypes 2, 3 and 7 are more prevalent than other serotypes and have been associated with severe pneumonia in pediatric children. Molecular typing of HAdV is not routinely performed in clinical diagnostic laboratories as it is time-consuming and labor-intensive. In the present study, we developed a triplex quantitative real-time PCR assay (tq-PCR) in a single closed tube for differential detection and quantitative analysis of HAdV serotypes 2, 3 and 7. The sensitivity, specificity, reproducibility and clinical performance of tq-PCR were evaluated. The analytical sensitivity of the tq-PCR was 100 copies/reaction for each of HAdV serotypes 2, 3 and 7, and no cross-reaction with other common respiratory viruses or HAdV serotypes 1,4,5,6,31,55 and 57 was observed. The coefficients of variation (CV) of intra-assay and inter-assay were between 0.6% to 3.6%. Of 138 previously-defined HAdV-positive nasopharyngeal aspirates samples tested, the detection agreement between tq-PCR and nested PCR was 96.38% (133/138). The proposed tq-PCR assay is a sensitive, specific and reproducible method and has the potential for clinical use in the rapid and differential detection and quantitation of HAdV serotypes 2, 3 and 7.

  17. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

    OpenAIRE

    Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Mart?nez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.; Cusini, M.

    2016-01-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient popul...

  18. PCR identification of bacteria in blood culture does not fit the daily workflow of a routine microbiology laboratory.

    Science.gov (United States)

    Karumaa, Santra; Kärpänoja, Pauliina; Sarkkinen, Hannu

    2012-03-01

    We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.

  19. Utility of a Multiplex PCR Assay for Detecting Herpesvirus DNA in Clinical Samples

    Science.gov (United States)

    Druce, Julian; Catton, Mike; Chibo, Doris; Minerds, Kirsty; Tyssen, David; Kostecki, Renata; Maskill, Bill; Leong-Shaw, Wendy; Gerrard, Marie; Birch, Chris

    2002-01-01

    A multiplex PCR was designed to amplify herpes simplex virus types 1 and 2, cytomegalovirus, and varicella-zoster virus DNA present in a diverse range of clinical material. The susceptibility of these viruses to in vivo inhibition by at least one antiviral drug was an important consideration in their inclusion in the multiplex detection system. An aliquot of equine herpesvirus was introduced into each specimen prior to extraction and served as an indicator of potential inhibitors of the PCR and a detector of suboptimal PCR conditions. Compared to virus isolation and immunofluorescence-based antigen detection, the multiplex assay yielded higher detection rates for all viruses represented in the assay. The turnaround time for performance of the assay was markedly reduced compared to those for the other techniques used to identify these viruses. More than 21,000 tests have been performed using the assay. Overall, the multiplex PCR enabled the detection of substantially increased numbers of herpesviruses, in some cases in specimens or anatomical sites where previously they were rarely if ever identified using traditional detection methods. PMID:11980951

  20. Clinical and Functional Assays of Radiosensitivity and Radiation-Induced Second Cancer

    Directory of Open Access Journals (Sweden)

    Mohammad Habash

    2017-10-01

    Full Text Available Whilst the near instantaneous physical interaction of radiation energy with living cells leaves little opportunity for inter-individual variation in the initial yield of DNA damage, all the downstream processes in how damage is recognized, repaired or resolved and therefore the ultimate fate of cells can vary across the population. In the clinic, this variability is observed most readily as rare extreme sensitivity to radiotherapy with acute and late tissue toxic reactions. Though some radiosensitivity can be anticipated in individuals with known genetic predispositions manifest through recognizable phenotypes and clinical presentations, others exhibit unexpected radiosensitivity which nevertheless has an underlying genetic cause. Currently, functional assays for cellular radiosensitivity represent a strategy to identify patients with potential radiosensitivity before radiotherapy begins, without needing to discover or evaluate the impact of the precise genetic determinants. Yet, some of the genes responsible for extreme radiosensitivity would also be expected to confer susceptibility to radiation-induced cancer, which can be considered another late adverse event associated with radiotherapy. Here, the utility of functional assays of radiosensitivity for identifying individuals susceptible to radiotherapy-induced second cancer is discussed, considering both the common mechanisms and important differences between stochastic radiation carcinogenesis and the range of deterministic acute and late toxic effects of radiotherapy.

  1. Localized single voxel 1H MR spectroscopy toward routine clinical use

    International Nuclear Information System (INIS)

    Lee, Jung Hee; Choi, Choong Gon; Kim, Sang Tae; Kim, Jin Suh; Mun, Chi Woong; Suh, Dae Chul; Lim, Tae Hwan; Auh, Young Ho

    1996-01-01

    To evaluate the automated 1 H magnetic resonance spectroscopy ( 1 H-MRS) method for a routine clinical use, various regions of the normal human brain were examined for regional variations, the reproducibility, and the quality control of the spectral data. Localized 1 H-MRS was performed in a GE 1.5T SIGNA MRI/MRS system using the automated method (PROton Brain Exam:PROBE). Six regions of the human brain from normal volunteers (N=25, age=23-65) were examined: Occipital gray matter, parietal white matter, frontal white matter, pons, cerebellum, and basal ganglia region. STEAM was used as the localization method with the following parameters : TE=30 msec, TR=3.0 sec, AVG=48 AVG, NEX=2, Spectral Width (SW)=2500 Hz, Size (SI)=2048 points (2K), and the size of voxel=7-9 ml. The reproducibility and the quality control of the spectral data were evaluated. For the 6 regions, the regional variation by the spectral patterns and the metabolites ratios relative to creatine was well demonstrated. Rates of the auto prescan success and the percentages of obtaining the acceptable quality spectral were high in the parietal white matter, occipital gray matter, and basal ganglia regions, and low in the frontal white matter and pons regions. PROBE is a highly practical as well as reliable method to produce reproducible quality spectra that represent the regional metabolic exam or as an additional series to a routine brain MRI exam, which takes less than 10 minutes for acquisition of one spectrum. In order to obtain good quality spectra, a good quality control scheme of the MR instrument is mandatory

  2. Incidental copy-number variants identified by routine genome testing in a clinical population

    Science.gov (United States)

    Boone, Philip M.; Soens, Zachry T.; Campbell, Ian M.; Stankiewicz, Pawel; Cheung, Sau Wai; Patel, Ankita; Beaudet, Arthur L.; Plon, Sharon E.; Shaw, Chad A.; McGuire, Amy L.; Lupski, James R.

    2013-01-01

    Purpose Mutational load of susceptibility variants has not been studied on a genomic scale in a clinical population, nor has the potential to identify these mutations as incidental findings during clinical testing been systematically ascertained. Methods Array comparative genomic hybridization, a method for genome-wide detection of DNA copy-number variants, was performed clinically on DNA from 9,005 individuals. Copy-number variants encompassing or disrupting single genes were identified and analyzed for their potential to confer predisposition to dominant, adult-onset disease. Multigene copy-number variants affecting dominant, adult-onset cancer syndrome genes were also assessed. Results In our cohort, 83 single-gene copy-number variants affected 40 unique genes associated with dominant, adult-onset disorders and unrelated to the patients’ referring diagnoses (i.e., incidental) were found. Fourteen of these copy-number variants are likely disease-predisposing, 25 are likely benign, and 44 are of unknown clinical consequence. When incidental copy-number variants spanning up to 20 genes were considered, 27 copy-number variants affected 17 unique genes associated with dominant, adult-onset cancer predisposition. Conclusion Copy-number variants potentially conferring susceptibility to adult-onset disease can be identified as incidental findings during routine genome-wide testing. Some of these mutations may be medically actionable, enabling disease surveillance or prevention; however, most incidentally observed single-gene copy-number variants are currently of unclear significance to the patient. PMID:22878507

  3. Narrative meaning making is associated with sudden gains in psychotherapy clients' mental health under routine clinical conditions.

    Science.gov (United States)

    Adler, Jonathan M; Harmeling, Luke H; Walder-Biesanz, Ilana

    2013-10-01

    The present study had two aims: (a) to replicate previous findings regarding the characteristics of sudden gains (SGs) in psychotherapy under routine clinical conditions and (b) to examine whether clients' narrative meaning-making processes were associated with SGs in mental health. 54 psychotherapy clients completed the Systemic Therapy Inventory of Change (Pinsof et al., 2009) and wrote private narratives prior to beginning treatment and between every session for 12 assessment points over the course of psychotherapy for a variety of presenting problems. Clients' narratives were coded using existing systems (Adler, 2012; A. M. Hayes, Feldman, & Goldfried, 2006) to assess their content in eight themes: processing, avoidance, coherence, positive self, negative self, agency, hope, and hopelessness. The prevalence, magnitude, and timing of SGs in mental health observed in the present study were similar to those observed in prior research. Two narrative meaning-making processes-processing and coherence-were significantly associated with SGs in mental health. The present study significantly extends prior research on SGs, replicating the characteristics of these gains in routine clinical conditions with a measure of general functioning and identifying two narrative meaning-making processes that are associated with SGs in mental health.

  4. Interpreting clinical assays for histone deacetylase inhibitors

    International Nuclear Information System (INIS)

    Martinet, Nadine; Bertrand, Philippe

    2011-01-01

    As opposed to genetics, dealing with gene expressions by direct DNA sequence modifications, the term epigenetics applies to all the external influences that target the chromatin structure of cells with impact on gene expression unrelated to the sequence coding of DNA itself. In normal cells, epigenetics modulates gene expression through all development steps. When “imprinted” early by the environment, epigenetic changes influence the organism at an early stage and can be transmitted to the progeny. Together with DNA sequence alterations, DNA aberrant cytosine methylation and microRNA deregulation, epigenetic modifications participate in the malignant transformation of cells. Their reversible nature has led to the emergence of the promising field of epigenetic therapy. The efforts made to inhibit in particular the epigenetic enzyme family called histone deacetylases (HDACs) are described. HDAC inhibitors (HDACi) have been proposed as a viable clinical therapeutic approach for the treatment of leukemia and solid tumors, but also to a lesser degree for noncancerous diseases. Three epigenetic drugs are already arriving at the patient’s bedside, and more than 100 clinical assays for HDACi are registered on the National Cancer Institute website. They explore the eventual additive benefits of combined therapies. In the context of the pleiotropic effects of HDAC isoforms, more specific HDACi and more informative screening tests are being developed for the benefit of the patients

  5. Objections to routine clinical outcomes measurement in mental health services: any evidence so far?

    Science.gov (United States)

    MacDonald, Alastair J D; Trauer, Tom

    2010-12-01

    Routine clinical outcomes measurement (RCOM) is gaining importance in mental health services. To examine whether criticisms published in advance of the development of RCOM have been borne out by data now available from such a programme. This was an observational study of routine ratings using HoNOS65+ at inception/admission and again at discharge in an old age psychiatry service from 1997 to 2008. Testable hypotheses were generated from each criticism amenable to empirical examination. Inter-rater reliability estimates were applied to observed differences between scores between community and ward patients using resampling. Five thousand one hundred eighty community inceptions and 862 admissions had HoNOS65+ ratings at referral/admission and discharge. We could find no evidence of gaming (artificially worse scores at inception and better at discharge), selection, attrition or detection bias, and ratings were consistent with diagnosis and level of service. Anticipated low levels of inter-rater reliability did not vitiate differences between levels of service. Although only hypotheses testable from within RCOM data were examined, and only 46% of eligible episodes had complete outcomes data, no evidence of the alleged biases were found. RCOM seems valid and practical in mental health services.

  6. The significance of routines in nursing practice.

    Science.gov (United States)

    Rytterström, Patrik; Unosson, Mitra; Arman, Maria

    2011-12-01

    The aim of this study was to illuminate the significance of routines in nursing practice. Clinical nursing is performed under the guidance of routines to varying degrees. In the nursing literature, routine is described as having both negative and positive aspects, but use of the term is inconsistent, and empirical evidence is sparse. In the research on organisational routines, a distinction is made between routine as a rule and routine as action. A qualitative design using a phenomenological-hermeneutic approach. Data collection from three focus groups focused on nurses' experience of routines. Seventeen individual interviews from a previous study focusing on caring culture were also analysed in a secondary qualitative analysis. All participants were employed as 'qualified nursing pool' nurses. Routines are experienced as pragmatic, obstructive and meaningful. The aim of the pragmatic routine was to ensure that daily working life works; this routine is practised more on the basis of rational arguments and obvious intentions. The obstructive routine had negative consequences for nursing practice and was described as nursing losing its humanity and violating the patient's integrity. The meaningful routine involved becoming one with the routine and for the nurses, it felt right and meaningful to adapt to it. Routines become meaningful when the individual action is in harmony with the cultural pattern on which the nursing work is based. Instead of letting contemporary practice passively become routine, routines can be assessed and developed using research and theoretical underpinnings as a starting point for nursing practice. Leaders have a special responsibility to develop and support meaningful routines. One approach could be to let wards examine their routines from a patient perspective on the basis of the themes of pragmatic, meaningful and obstructive routine. © 2010 Blackwell Publishing Ltd.

  7. Assessment of three frequently used blood glucose monitoring devices in clinical routine.

    Science.gov (United States)

    Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R

    2012-07-12

    Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.

  8. A multiplex real-time PCR assay for routine diagnosis of bacterial vaginosis

    NARCIS (Netherlands)

    Kusters, J. G.; Reuland, E. A.; Bouter, S.; Koenig, P.; Dorigo-Zetsma, J. W.

    2015-01-01

    A semi-quantitative multiplex PCR assay for the diagnosis of bacterial vaginosis (BV) was evaluated in a prospective study in a population of Dutch women with complaints of abnormal vaginal discharge. The PCR targets Gardnerella vaginalis, Atopobium vaginae, Megasphaera phylotype 1, Lactobacillus

  9. Investigation of Factors Affecting Body Temperature Changes During Routine Clinical Head Magnetic Resonance Imaging

    Science.gov (United States)

    Kim, Myeong Seong

    2016-01-01

    Background Pulsed radiofrequency (RF) magnetic fields, required to produce magnetic resonance imaging (MRI) signals from tissue during the MRI procedure have been shown to heat tissues. Objectives To investigate the relationship between body temperature rise and the RF power deposited during routine clinical MRI procedures, and to determine the correlation between this effect and the body’s physiological response. Patients and Methods We investigated 69 patients from the Korean national cancer center to identify the main factors that contribute to an increase in body temperature (external factors and the body’s response) during a clinical brain MRI. A routine protocol sequence of MRI scans (1.5 T and 3.0 T) was performed. The patient’s tympanic temperature was recorded before and immediately after the MRI procedure and compared with changes in variables related to the body’s physiological response to heat. Results Our investigation of the physiological response to RF heating indicated a link between increasing age and body temperature. A higher increase in body temperature was observed in older patients after a 3.0-T MRI (r = 0.07, P = 0.29 for 1.5-T MRI; r = 0.45, P = 0.002 for 3.0-T MRI). The relationship between age and body heat was related to the heart rate (HR) and changes in HR during the MRI procedure; a higher RF power combined with a reduction in HR resulted in an increase in body temperature. Conclusion A higher magnetic field strength and a decrease in the HR resulted in an increase in body temperature during the MRI procedure. PMID:27895872

  10. Diagnostic outcome following routine genetics clinic referral for the assessment of global developmental delay.

    LENUS (Irish Health Repository)

    Shahdadpuri, R

    2012-02-01

    The aim of this study was to ascertain the diagnostic yield following a routine genetics clinic referral for the assessment of global developmental delay. Detailed retrospective review of 119 complete consecutive case notes of patients referred to one single clinical geneticist over a 14 month time period was undertaken (n = 119; 54 males, 65 females). The age at initial review ranged from 2 months to 37 years 3 months (mean 8 y 3 mo [SD 7 y 10 mo]). We made a diagnosis in 36\\/119 (30%); 21\\/36 were new diagnoses and 15\\/36 were confirmations of diagnoses. We removed a wrong diagnostic label in 8\\/119 (7%). In 3\\/8 we were able to achieve a diagnosis but in 5\\/8 no alternative diagnosis was reached. We had a better diagnostic rate where the patients were dysmorphic (odds ratio [OR] 1.825; 95% confidence interval [CI] 1.065 to 3.128, p = 0.044). In the majority, the diagnosis was made by clinical examination only. Molecular diagnosis was reached in seven cases. Five cases were confirmed by cytogenetic analysis. Brain magnetic resonance imaging (MRI) revealed a diagnosis in three cases. This study confirms the importance of a clinical genetics assessment in the investigation of global developmental delay.

  11. Quality Control Assays for Clinical-Grade Human Mesenchymal Stromal Cells: Methods for ATMP Release.

    Science.gov (United States)

    Radrizzani, Marina; Soncin, Sabrina; Lo Cicero, Viviana; Andriolo, Gabriella; Bolis, Sara; Turchetto, Lucia

    2016-01-01

    Mesenchymal stromal/stem cells (MSC) are promising candidates for the development of cell-based therapies for various diseases and are currently being evaluated in a number of clinical trials (Sharma et al., Transfusion 54:1418-1437, 2014; Ikebe and Suzuki, Biomed Res Int 2014:951512, 2014). MSC for therapeutic applications are classified as advanced therapy medicinal products (ATMP) (Regulation (EC) No 1394/2007 of the European Parliament and of the Council of 13 November 2007 on advanced therapy medicinal products and amending Directive 2001/83/EC and Regulation (EC) No 726/2004) and must be prepared according to good manufacturing practices ( http://ec.europa.eu/health/documents/eudralex/vol-4 ). They may be derived from different starting materials (mainly bone marrow (BM), adipose tissue, or cord blood) and applied as fresh or cryopreserved products, in the autologous as well as an allogeneic context (Sharma et al., Transfusion 54:1418-1437, 2014; Ikebe and Suzuki, Biomed Res Int 2014:951512, 2014; Sensebé and Bourin, Transplantation 87(9 Suppl):S49-S53, 2009). In any case, they require an approved and well-defined panel of assays in order to be released for clinical use.This chapter describes analytical methods implemented and performed in our cell factory as part of the release strategy for an ATMP consisting of frozen autologous BM-derived MSC. Such methods are designed to assess the safety (sterility, endotoxin, and mycoplasma assays) and identity/potency (cell count and viability, immunophenotype and clonogenic assay) of the final product. Some assays are also applied to the biological starting material (sterility) or carried out as in-process controls (sterility, cell count and viability, immunophenotype, clonogenic assay).The validation strategy for each analytical method is described in the accompanying Chapter 20 .

  12. Evaluation of a multiplex real-time PCR assay for the detection of respiratory viruses in clinical specimens.

    Science.gov (United States)

    Rheem, Insoo; Park, Joowon; Kim, Tae-Hyun; Kim, Jong Wan

    2012-11-01

    In this study, we evaluated the analytical performance and clinical potential of a one-step multiplex real-time PCR assay for the simultaneous detection of 14 types of respiratory viruses using the AdvanSure RV real-time PCR Kit (LG Life Sciences, Korea). Three hundred and twenty clinical specimens were tested with the AdvanSure RV real-time PCR Kit and conventional multiplex reverse transcription (RT)-PCR assay. The assay results were analyzed and the one-step AdvanSure RV real-time PCR Kit was compared with the conventional multiplex RT-PCR assay with respect to the sensitivity and specificity of the detection of respiratory viruses. The limit of detection (LOD) was 1.31 plaque-forming units (PFU)/mL for human rhinoviruses (hRVs), 4.93 PFU/mL for human coronavirus HCoV-229E/NL63, 2.67 PFU/mL for human coronavirus HCoV-OC43, 18.20 PFU/mL for parainfluenza virus 1 (PIV)-1, 24.57 PFU/mL for PIV-2, 1.73 PFU/mL for PIV-3, 1.79 PFU/mL for influenza virus group (Flu) A, 59.51 PFU/mL for FluB, 5.46 PFU/mL for human respiratory syncytial virus (hRSV)-A, 17.23 PFU/mL for hRSV-B, 9.99 PFU/mL for human adenovirus (ADVs). The cross-reactivity test for this assay against 23 types of non-respiratory viruses showed negative results for all viruses tested. The agreement between the one-step AdvanSure multiplex real-time PCR assay and the conventional multiplex RT-PCR assay was 98%. The one-step AdvanSure RV multiplex real-time PCR assay is a simple assay with high potential for specific, rapid and sensitive laboratory diagnosis of respiratory viruses compared to conventional multiplex RT-PCR.

  13. Rapid susceptibility testing of Mycobacterium tuberculosis by bioluminescence assay of mycobacterial ATP

    International Nuclear Information System (INIS)

    Nilsson, L.E.; Hoffner, S.E.; Ansehn, S.

    1988-01-01

    Mycobacterial growth was monitored by bioluminescence assay of mycobacterial ATP. Cultures of Mycobacterium tuberculosis H37Rv and of 25 clinical isolates of the same species were exposed to serial dilutions of ethambutol, isoniazid, rifampin, and streptomycin. A suppression of ATP, indicating growth inhibition, occurred for susceptible but not resistant strains within 5 to 7 days of incubation. Breakpoint concentrations between susceptibility and resistance were determined by comparing these results with those obtained by reference techniques. Full agreement was found in 99% of the assays with the resistance ratio method on Lowenstein-Jensen medium, and 98% of the assays were in full agreement with the radiometric system (BACTEC). A main advantage of the bioluminescence method is its rapidity, with results available as fast as with the radiometric system but at a lower cost and without the need for radioactive culture medium. The method provides kinetic data concerning drug effects within available in vivo drug concentrations and has great potential for both rapid routine susceptibility testing and research applications in studies of drug effects on mycobacteria

  14. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    Science.gov (United States)

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  15. Assessing barriers to adherence in routine clinical care for pediatric kidney transplant patients.

    Science.gov (United States)

    Varnell, Charles D; Rich, Kristin L; Nichols, Melissa; Dahale, Devesh; Goebel, Jens W; Pai, Ahna L H; Hooper, David K; Modi, Avani C

    2017-11-01

    Patient-identified barriers to immunosuppressive medications are associated with poor adherence and negative clinical outcomes in transplant patients. Assessment of adherence barriers is not part of routine post-transplant care, and studies regarding implementing such a process in a reliable way are lacking. Using the Model for Improvement and PDSA cycles, we implemented a system to identify adherence barriers, including patient-centered design of a barriers assessment tool, identification of eligible patients, clear roles for clinic staff, and creating a culture of non-judgmental discussion around adherence. We performed time-series analysis of our process measure. Secondary analyses examined the endorsement and concordance of adherence barriers between patient-caregiver dyads. After three methods of testing, the most reliable delivery system was an EHR-integrated tablet that alerted staff of patient eligibility for assessment. Barriers were endorsed by 35% of caregivers (n=85) and 43% of patients (n=60). The most frequently patient-endorsed barriers were forgetting, poor taste, and side effects. Caregivers endorsed forgetting and side effects. Concordance between patient-caregiver dyads was fair (k=0.299). Standardized adherence barriers assessment is feasible in the clinical care of pediatric kidney transplant patients. Features necessary for success included automation, redundant systems with designated staff to identify and mitigate failures, aligned reporting structures, and reliable measurement approaches. Future studies will examine whether barriers predict clinical outcomes (eg, organ rejection, graft loss). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Use of monoclonal immunoradiometric assays for sensitive TSH measurements: evaluation of four commercially obtainable kits

    International Nuclear Information System (INIS)

    Smitz, J.; Schiettecatte, J.; Stierteghem, A.C. van; Jonckheer, M.H.

    1987-01-01

    Four commerically available monoclonal immunoradiometric methods for the assay of TSH are tested. These four kits are: RIA-GNOST TSH code 0CPL of Behring, SUCROSEP TSH IRMA of Boots, TSH-IRMA-CT-100 of Medgenix, TSH-RIA bead II Ultrasensitive of Abbott. The accuracy, sensitivity and reproducibility of the four kits are compared. The methods are also clinically evaluated. The authors concluded that the kits of Abbott, Behring and Boots are suitable for use in the routine laboratory. 4 refs.; 4 figs.; 7 tabs

  17. Clinical and economic impact of the introduction of a nucleic acid amplification assay for Clostridium difficile.

    Science.gov (United States)

    Guinta, Margaret M; Bunnell, Kristen; Harrington, Amanda; Bleasdale, Susan; Danziger, Larry; Wenzler, Eric

    2017-12-04

    The clinical outcomes and cost implications of a diagnostic shift from an EIA- to PCR-based assay for Clostridium difficile infection (CDI) have not been completely described in the literature. The impact of the PCR-based assay on the incidence and duration of CDI therapy was compared to the EIA assay for patients with a negative CDI diagnostic result. Secondary clinical and economic outcomes were also evaluated. Independent predictors of receipt of antibiotic therapy were assessed via logistic regression. 141 EIA and 140 PCR patients were included. Significantly more patients were started or continued on anti-CDI antibiotic therapy after a known negative assay result in the EIA group (26 patients vs. 8 patients, P = 0.002). Duration of antibiotic therapy after a known negative result was significantly shorter in the PCR group (1 vs. 4 days, P = 0.029) and a 23% reduction in the number of tests obtained per patient was observed (1.41 ± 0.86 vs. 1.82 ± 1.35, P = 0.007). The over fourfold difference in per-test cost of the EIA assay ($8.33 vs. $42.86, P costs required for the increased treatment in the EIA group ($546.60 vs. $188.96, P = 0.191). Utilization of the EIA-based CDI assay was associated with increased odds of CDI treatment after a negative test (aOR 4.71, 95% CI 1.93-11.46, P = 0.001). The transition from an EIA to PCR-based assay for diagnosing CDI resulted in a significant decrease in the number of patients treated and the duration of treatment in response to a negative test result. This significant decrease in treatment resulted in decreased costs offsetting the utilization of a more expensive molecular test for patients with a negative CDI diagnostic result.

  18. Fundamental and clinical evaluation of ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen

    International Nuclear Information System (INIS)

    Koizumi, Mitsuru; Endo, Keigo; Nakajima, Kotoko

    1987-01-01

    A commercial ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen (SCC antigen) was fundamentally and clinically evaluated. Laboratory performance was satisfactory for intra-assay and inter-assay reproducibility, recovery, and dilution, with rapid and simple measurement techniques. Seropositivity for SCC antigen was significantly higher for squamous cell carcinoma of the liver and uterine cervix than the other histology types. In the case of cervical squamous cell carcinoma, it increased with progressing disease. Post-treatment serum levels of SCC antigen returned to negative. SCC antigen is considered to be a useful tumor marker for these diseases. There was a good correlation between the measurement values obtained from the present and conventional (SCC RIAKIT) assays. The present assay remarkably decreased false-positive cases of pulmonary benign diseases. The results showed a ''SCC RIABEAD'' to be a favorable kit for immunoradiometric assay of SSC antigen, as compared with conventional assay kit. (Namekawa, K.)

  19. Herpes Murine Model as a Biological Assay to Test Dialyzable Leukocyte Extracts Activity

    Directory of Open Access Journals (Sweden)

    Nohemí Salinas-Jazmín

    2015-01-01

    Full Text Available Human dialyzable leukocyte extracts (DLEs are heterogeneous mixtures of low-molecular-weight peptides that are released on disruption of peripheral blood leukocytes from healthy donors. DLEs improve clinical responses in infections, allergies, cancer, and immunodeficiencies. Transferon is a human DLE that has been registered as a hemoderivate by Mexican health authorities and commercialized nationally. To develop an animal model that could be used routinely as a quality control assay for Transferon, we standardized and validated a murine model of cutaneous HSV-1 infection. Using this model, we evaluated the activity of 27 Transferon batches. All batches improved the survival of HSV-1-infected mice, wherein average survival rose from 20.9% in control mice to 59.6% in Transferon-treated mice. The activity of Transferon correlated with increased serum levels of IFN-γ and reduced IL-6 and TNF-α concentrations. Our results demonstrate that (i this mouse model of cutaneous herpes can be used to examine the activity of DLEs, such as Transferon; (ii the assay can be used as a routine test for batch release; (iii Transferon is produced with high homogeneity between batches; (iv Transferon does not have direct virucidal, cytoprotective, or antireplicative effects; and (v the protective effect of Transferon in vivo correlates with changes in serum cytokines.

  20. Comparison of human immunodeficiency virus type 1 tropism profiles in clinical samples by the Trofile and MT-2 assays.

    Science.gov (United States)

    Coakley, Eoin; Reeves, Jacqueline D; Huang, Wei; Mangas-Ruiz, Marga; Maurer, Irma; Harskamp, Agnes M; Gupta, Soumi; Lie, Yolanda; Petropoulos, Christos J; Schuitemaker, Hanneke; van 't Wout, Angélique B

    2009-11-01

    The recent availability of CCR5 antagonists as anti-human immunodeficiency virus (anti-HIV) therapeutics has highlighted the need to accurately identify CXCR4-using variants in patient samples when use of this new drug class is considered. The Trofile assay (Monogram Biosciences) has become the method that is the most widely used to define tropism in the clinic prior to the use of a CCR5 antagonist. By comparison, the MT-2 assay has been used since early in the HIV epidemic to define tropism in clinical specimens. Given that there are few data from direct comparisons of these two assays, we evaluated the performance of the plasma-based Trofile assay and the peripheral blood mononuclear cell (PBMC)-based MT-2 assay for the detection of CXCR4 use in defining the tropism of HIV isolates derived from clinical samples. The various samples used for this comparison were derived from participants of the Amsterdam Cohort Studies on HIV infection and AIDS who underwent consecutive MT-2 assay testing of their PBMCs at approximately 3-month intervals. This unique sample set was specifically selected because consecutive MT-2 assays had demonstrated a shift from negative to positive in PBMCs, reflecting the first emergence of CXCR4-using virus in PBMCs above the level of detection of the assay in these individuals. Trofile testing was performed with clonal HIV type 1 (HIV-1) variants (n = 21), MT-2 cell culture-derived cells (n = 20) and supernatants (n = 42), and plasma samples (n = 76). Among the clonal HIV-1 variants and MT-2 cell culture-derived samples, the results of the Trofile and MT-2 assays demonstrated a high degree of concordance (95% to 98%). Among consecutive plasma samples, detection of CXCR4-using virus was at or before the time of first detection by the MT-2 assay in 5/10 patients by the original Trofile assay and in 9/10 patients by the enhanced-sensitivity Trofile assay. Differences in the time to the first detection of CXCR4 use between the MT-2 assay (PBMCs

  1. Are self-report scales as effective as clinician rating scales in measuring treatment response in routine clinical practice?

    Science.gov (United States)

    Zimmerman, Mark; Walsh, Emily; Friedman, Michael; Boerescu, Daniela A; Attiullah, Naureen

    2018-01-01

    Recent treatment guidelines have suggested that outcome should be measured in routine clinical practice. In the present report from the Rhode Island Methods to Improve Diagnostic Assessment and Services (MIDAS) project, we compared three self-report scales of depressive symptoms and the two most widely used clinician administered scales in treatment studies in their sensitivity to change and evaluation of treatment response in depressed patients treated in routine practice. At baseline and 4-month follow-up 153 depressed outpatients with DSM-IV MDD completed the Clinically Useful Depression Outcome Scale (CUDOS), Quick Inventory of Depressive Symptomatology-Self-report version (QIDS-SR), and Patient Health Questionnaire (PHQ-9). The patients were rated on the 17-item Hamilton Depression Rating Scale (HAMD) and the Montgomery-Asberg Depression Rating Scale (MADRS). On each scale treatment response was defined as a 50% or greater reduction in scores from baseline. While there were some differences in the percentage of patients considered to be responders on the different scales, a large effect size was found for each scale, with little variability amongst the scales. The level of agreement between the three self-report scales and the clinician rating scales was approximately the same LIMITATIONS: The present study was conducted in a single clinical practice in which the majority of the patients were white, female, and had health insurance. When measuring outcome in clinical practice the magnitude of change in depressive symptoms is as great on self-report scales as on clinician rating scales. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Development and validation of Burkholderia pseudomallei-specific real-time PCR assays for clinical, environmental or forensic detection applications.

    Directory of Open Access Journals (Sweden)

    Erin P Price

    Full Text Available The bacterium Burkholderia pseudomallei causes melioidosis, a rare but serious illness that can be fatal if untreated or misdiagnosed. Species-specific PCR assays provide a technically simple method for differentiating B. pseudomallei from near-neighbor species. However, substantial genetic diversity and high levels of recombination within this species reduce the likelihood that molecular signatures will differentiate all B. pseudomallei from other Burkholderiaceae. Currently available molecular assays for B. pseudomallei detection lack rigorous validation across large in silico datasets and isolate collections to test for specificity, and none have been subjected to stringent quality control criteria (accuracy, precision, selectivity, limit of quantitation (LoQ, limit of detection (LoD, linearity, ruggedness and robustness to determine their suitability for environmental, clinical or forensic investigations. In this study, we developed two novel B. pseudomallei specific assays, 122018 and 266152, using a dual-probe approach to differentiate B. pseudomallei from B. thailandensis, B. oklahomensis and B. thailandensis-like species; other species failed to amplify. Species specificity was validated across a large DNA panel (>2,300 samples comprising Burkholderia spp. and non-Burkholderia bacterial and fungal species of clinical and environmental relevance. Comparison of assay specificity to two previously published B. pseudomallei-specific assays, BurkDiff and TTS1, demonstrated comparable performance of all assays, providing between 99.7 and 100% specificity against our isolate panel. Last, we subjected 122018 and 266152 to rigorous quality control analyses, thus providing quantitative limits of assay performance. Using B. pseudomallei as a model, our study provides a framework for comprehensive quantitative validation of molecular assays and provides additional, highly validated B. pseudomallei assays for the scientific research community.

  3. A rapid phospholipase D assay using zirconium precipitation of anionic substrate phospholipids

    DEFF Research Database (Denmark)

    Petersen, G.; Hansen, Harald S.; Chapman, K.D.

    2000-01-01

    -acylphosphatidylethanolamine (NAPE)-hydrolyzing PLD activity, which produces two lipophilic products, N-acylethanolamine (NAE) and phosphatidic acid. Therefore, we developed a rapid assay for the routine detection of NAPE-hydrolyzing PLD activity. This assay is based on precipitation of radiolabeled substrate (NAPE) in the presence...

  4. Canary: an atomic pipeline for clinical amplicon assays.

    Science.gov (United States)

    Doig, Kenneth D; Ellul, Jason; Fellowes, Andrew; Thompson, Ella R; Ryland, Georgina; Blombery, Piers; Papenfuss, Anthony T; Fox, Stephen B

    2017-12-15

    High throughput sequencing requires bioinformatics pipelines to process large volumes of data into meaningful variants that can be translated into a clinical report. These pipelines often suffer from a number of shortcomings: they lack robustness and have many components written in multiple languages, each with a variety of resource requirements. Pipeline components must be linked together with a workflow system to achieve the processing of FASTQ files through to a VCF file of variants. Crafting these pipelines requires considerable bioinformatics and IT skills beyond the reach of many clinical laboratories. Here we present Canary, a single program that can be run on a laptop, which takes FASTQ files from amplicon assays through to an annotated VCF file ready for clinical analysis. Canary can be installed and run with a single command using Docker containerization or run as a single JAR file on a wide range of platforms. Although it is a single utility, Canary performs all the functions present in more complex and unwieldy pipelines. All variants identified by Canary are 3' shifted and represented in their most parsimonious form to provide a consistent nomenclature, irrespective of sequencing variation. Further, proximate in-phase variants are represented as a single HGVS 'delins' variant. This allows for correct nomenclature and consequences to be ascribed to complex multi-nucleotide polymorphisms (MNPs), which are otherwise difficult to represent and interpret. Variants can also be annotated with hundreds of attributes sourced from MyVariant.info to give up to date details on pathogenicity, population statistics and in-silico predictors. Canary has been used at the Peter MacCallum Cancer Centre in Melbourne for the last 2 years for the processing of clinical sequencing data. By encapsulating clinical features in a single, easily installed executable, Canary makes sequencing more accessible to all pathology laboratories. Canary is available for download as source

  5. Subsolid pulmonary nodule morphology and associated patient characteristics in a routine clinical population

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Utrecht (Netherlands); Scholten, Ernst T.; Chung, Kaman; Ginneken, Bram van [Radboud University Nijmegen Medical Centre, Diagnostic Imaging Analysis Group, Nijmegen (Netherlands); Schaefer-Prokop, Cornelia M. [Radboud University Nijmegen Medical Centre, Diagnostic Imaging Analysis Group, Nijmegen (Netherlands); Meander Medical Center, Radiology, Amersfoort (Netherlands)

    2017-02-15

    To determine the presence and morphology of subsolid pulmonary nodules (SSNs) in a non-screening setting and relate them to clinical and patient characteristics. A total of 16,890 reports of clinically obtained chest CT (06/2011 to 11/2014, single-centre) were searched describing an SSN. Subjects with a visually confirmed SSN and at least two thin-slice CTs were included. Nodule volumes were measured. Progression was defined as volume increase exceeding the software interscan variation. Nodule morphology, location, and patient characteristics were evaluated. Fifteen transient and 74 persistent SSNs were included (median follow-up 19.6 [8.3-36.8] months). Subjects with an SSN were slightly older than those without (62 vs. 58 years; p = 0.01), but no gender predilection was found. SSNs were mostly located in the upper lobes. Women showed significantly more often persistent lesions than men (94 % vs. 69 %; p = 0.002). Part-solid lesions were larger (1638 vs. 383 mm{sup 3}; p < 0.001) and more often progressive (68 % vs. 38 %; p = 0.02), compared to pure ground-glass nodules. Progressive SSNs were rare under the age of 50 years. Logistic regression analysis did not identify additional nodule parameters of future progression, apart from part-solid nature. This study confirms previously reported characteristics of SSNs and associated factors in a European, routine clinical population. (orig.)

  6. Subsolid pulmonary nodule morphology and associated patient characteristics in a routine clinical population

    International Nuclear Information System (INIS)

    Mets, Onno M.; Jong, Pim A. de; Scholten, Ernst T.; Chung, Kaman; Ginneken, Bram van; Schaefer-Prokop, Cornelia M.

    2017-01-01

    To determine the presence and morphology of subsolid pulmonary nodules (SSNs) in a non-screening setting and relate them to clinical and patient characteristics. A total of 16,890 reports of clinically obtained chest CT (06/2011 to 11/2014, single-centre) were searched describing an SSN. Subjects with a visually confirmed SSN and at least two thin-slice CTs were included. Nodule volumes were measured. Progression was defined as volume increase exceeding the software interscan variation. Nodule morphology, location, and patient characteristics were evaluated. Fifteen transient and 74 persistent SSNs were included (median follow-up 19.6 [8.3-36.8] months). Subjects with an SSN were slightly older than those without (62 vs. 58 years; p = 0.01), but no gender predilection was found. SSNs were mostly located in the upper lobes. Women showed significantly more often persistent lesions than men (94 % vs. 69 %; p = 0.002). Part-solid lesions were larger (1638 vs. 383 mm"3; p < 0.001) and more often progressive (68 % vs. 38 %; p = 0.02), compared to pure ground-glass nodules. Progressive SSNs were rare under the age of 50 years. Logistic regression analysis did not identify additional nodule parameters of future progression, apart from part-solid nature. This study confirms previously reported characteristics of SSNs and associated factors in a European, routine clinical population. (orig.)

  7. Audit of the autoantibody test, EarlyCDT®-lung, in 1600 patients: an evaluation of its performance in routine clinical practice.

    Science.gov (United States)

    Jett, James R; Peek, Laura J; Fredericks, Lynn; Jewell, William; Pingleton, William W; Robertson, John F R

    2014-01-01

    EarlyCDT(®)-Lung may enhance detection of early stage lung cancer by aiding physicians in assessing high-risk patients through measurement of biological markers (i.e., autoantibodies). The test's performance characteristics in routine clinical practice were evaluated by auditing clinical outcomes of 1613 US patients deemed at high risk for lung cancer by their physician, who ordered the EarlyCDT-Lung test for their patient. Clinical outcomes for all 1613 patients who provided HIPAA authorization are reported. Clinical data were collected from each patient's treating physician. Pathology reports when available were reviewed for diagnostic classification. Staging was assessed on histology, otherwise on imaging. Six month follow-up for the positives/negatives was 99%/93%. Sixty-one patients (4%) were identified with lung cancer, 25 of whom tested positive by EarlyCDT-Lung (sensitivity=41%). A positive EarlyCDT-Lung test on the current panel was associated with a 5.4-fold increase in lung cancer incidence versus a negative. Importantly, 57% (8/14) of non-small cell lung cancers detected as positive (where stage was known) were stage I or II. EarlyCDT-Lung has been extensively tested and validated in case-control settings and has now been shown in this audit to perform in routine clinical practice as predicted. EarlyCDT-Lung may be a complementary tool to CT for detection of early lung cancer. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  9. Genetic alterations in lung cancer: Assessing limitations in routine clinical use

    Directory of Open Access Journals (Sweden)

    Joana Espiga Macedo

    2007-01-01

    Full Text Available Lung cancer is the most frequent cause of cancer mortality worldwide, responsible for approximately 1.1 million deaths per year. Median survival is short, both as most tumours are diagnosed at an advanced stage and because of the limited efficacy of available treatments. The development of tumour molecular genetics carries the promise of altering this state of affairs, as it should lead to a more precise classification of tumours, identify specific molecular targets for therapy and, above all, allow the development of new methods for early diagnosis. Despite numerous studies demonstrating the usefulness of molecular genetic techniques in the study of lung cancer, its routine clinical use in Portugal has, however, been limited.In this study, we used a p53 mutation screen in multiple clinical samples from a series of lung cancer patients to attempt to identify the main practical limitations to the integration of molecular genetics in routine clinical practice. Our results suggest that the main limiting factor is the availability of samples with good quality DNA; a problem that could be overcome by alterations in common sample collection and storage procedures. Resumo: O cancro do pulmão é a causa mais frequente de mortalidade por cancro no mundo, sendo responsável por cerca de 1,1 milhões de mortes por ano. A sobrevivência média dos doentes é geralmente curta, por a doença se encontrar em estádios avançados na altura do diagnóstico, mas também devido à falta de eficácia dos tratamentos disponíveis. O advento da genética molecular dos tumores trouxe consigo a possibilidade de modificar esta situação, quer através do refinamento do diagnóstico, quer da identificação de alvos terapêuticos específicos, quer sobretudo por – pelo menos em teoria – permitir o diagnóstico precoce da doença. No entanto, e apesar de numerosos trabalhos terem já demonstrado a utilidade

  10. Clinical utility of routine MPL exon 10 analysis in the diagnosis of essential thrombocythaemia and primary myelofibrosis.

    Science.gov (United States)

    Boyd, Elaine M; Bench, Anthony J; Goday-Fernández, Andrea; Anand, Shubha; Vaghela, Krishna J; Beer, Phillip; Scott, Mike A; Bareford, David; Green, Anthony R; Huntly, Brian; Erber, Wendy N

    2010-04-01

    Approximately 50% of essential thrombocythaemia and primary myelo-fibrosis patients do not have a JAK2 V617F mutation. Up to 5% of these are reported to have a MPL exon 10 mutation but testing for MPL is not routine as there are multiple mutation types. The ability to routinely assess both JAK2 and MPL mutations would be beneficial in the differential diagnosis of unexplained thrombocytosis or myelofibrosis. We developed and applied a high resolution melt (HRM) assay, capable of detecting all known MPL mutations in a single analysis, for the detection of MPL exon 10 mutations. We assessed 175 ET and PMF patients, including 67 that were JAK2 V617F-negative by real time polymerase chain reaction (PCR). Overall, 19/175 (11%) patients had a MPL exon 10 mutation, of whom 16 were JAK2 V617F-negative (16/67; 24%). MPL mutation types were W515L (11), W515K (4), W515R (2) and W515A (1). One patient had both W515L and S505N MPL mutations and these were present in the same haemopoietic colonies. Real time PCR for JAK2 V617F analysis and HRM for MPL exon 10 status identified one or more clonal marker in 71% of patients. This combined genetic approach increases the sensitivity of meeting the World Health Organization diagnostic criteria for these myeloproliferative neoplasms.

  11. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  12. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  13. A simple clot based assay for detection of procoagulant cell-derived microparticles.

    Science.gov (United States)

    Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati

    2016-05-01

    Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.

  14. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials

    International Nuclear Information System (INIS)

    Plorde, J.J.; Carlson, L.G.; Dau, M.E.

    1982-01-01

    During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture

  15. Usefulness of component resolved analysis of cat allergy in routine clinical practice.

    Science.gov (United States)

    Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future

  16. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  17. Sequencing-based breast cancer diagnostics as an alternative to routine biomarkers.

    Science.gov (United States)

    Rantalainen, Mattias; Klevebring, Daniel; Lindberg, Johan; Ivansson, Emma; Rosin, Gustaf; Kis, Lorand; Celebioglu, Fuat; Fredriksson, Irma; Czene, Kamila; Frisell, Jan; Hartman, Johan; Bergh, Jonas; Grönberg, Henrik

    2016-11-30

    Sequencing-based breast cancer diagnostics have the potential to replace routine biomarkers and provide molecular characterization that enable personalized precision medicine. Here we investigate the concordance between sequencing-based and routine diagnostic biomarkers and to what extent tumor sequencing contributes clinically actionable information. We applied DNA- and RNA-sequencing to characterize tumors from 307 breast cancer patients with replication in up to 739 patients. We developed models to predict status of routine biomarkers (ER, HER2,Ki-67, histological grade) from sequencing data. Non-routine biomarkers, including mutations in BRCA1, BRCA2 and ERBB2(HER2), and additional clinically actionable somatic alterations were also investigated. Concordance with routine diagnostic biomarkers was high for ER status (AUC = 0.95;AUC(replication) = 0.97) and HER2 status (AUC = 0.97;AUC(replication) = 0.92). The transcriptomic grade model enabled classification of histological grade 1 and histological grade 3 tumors with high accuracy (AUC = 0.98;AUC(replication) = 0.94). Clinically actionable mutations in BRCA1, BRCA2 and ERBB2(HER2) were detected in 5.5% of patients, while 53% had genomic alterations matching ongoing or concluded breast cancer studies. Sequencing-based molecular profiling can be applied as an alternative to histopathology to determine ER and HER2 status, in addition to providing improved tumor grading and clinically actionable mutations and molecular subtypes. Our results suggest that sequencing-based breast cancer diagnostics in a near future can replace routine biomarkers.

  18. Applying a Real-Time PCR Assay for Histoplasma capsulatum to Clinically Relevant Formalin-Fixed Paraffin-Embedded Human Tissue

    Science.gov (United States)

    Koepsell, Scott A.; Hinrichs, Steven H.

    2012-01-01

    A real-time PCR assay to detect Histoplasma capsulatum in formalin-fixed, paraffin-embedded (FFPE) tissue is described. The assay had an analytical sensitivity of 6 pg/μl of fungal DNA, analytical specificity of 100%, and clinical sensitivity of 88.9%. This proof-of-concept study may aid in the diagnosis of histoplasmosis from FFPE tissue. PMID:22855519

  19. Cell Line Controls for the Genotyping of a Spectrum of Human Single Nucleotide Polymorphisms in the Clinical Laboratory.

    Science.gov (United States)

    Kimbacher, Christine; Paar, Christian; Freystetter, Andrea; Berg, Joerg

    2018-05-01

    Genotyping for clinically important single nucleotide polymorphisms (SNPs) is performed by many clinical routine laboratories. To support testing, quality controls and reference materials are needed. Those may be derived from residual patient samples, left over samples of external quality assurance schemes, plasmid DNA or DNA from cell lines. DNAs from cell lines are commutable and available in large amounts. DNA from 38 cell lines were examined for suitability as controls in 11 SNP assays that are frequently used in a clinical routine laboratory: FV (1691G>A), FII (20210G>A), PAI-1 4G/5G polymorphism, MTHFR (677C>T, 1298A>C), HFE (H63D, S65C, C282Y), APOE (E2, E3, E4), LPH (-13910C>T), UGT1A1 (*28, *36, *37), TPMT (*2, *3A, *3B, *3C), VKORC1 (-1639G>A, 1173C>T), CYP2C9 (*2, *3, *5). Genotyping was performed by real-time PCR with melting curve analysis and confirmed by bi-directional sequencing. We find an almost complete spectrum of genotypic constellations within these 38 cell lines. About 12 cell lines appear sufficient as genotypic controls for the 11 SNP assays by covering almost all of the genotypes. However, hetero- and homozygous genotypes for FII and the alleles TPMT*2, UGT1A1*37 and CYP2C9*5 were not detected in any of the cell lines. DNA from most of the examined cell lines appear suitable as quality controls for these SNP assays in the laboratory routine, as to the implementation of those assays or to prepare samples for quality assurance schemes. Our study may serve as a pilot to further characterize these cell lines to arrive at the status of reference materials.

  20. Toward Clarity in Clinical Vitamin D Status Assessment: 25(OH)D Assay Standardization.

    Science.gov (United States)

    Binkley, Neil; Carter, Graham D

    2017-12-01

    Widespread variation in 25-hydroxyvitamin D (25(OH)D) assays continues to compromise efforts to develop clinical and public health guidelines regarding vitamin D status. The Vitamin D Standardization Program helps alleviate this problem. Reference measurement procedures and standard reference materials have been developed to allow current, prospective, and retrospective standardization of 25(OH)D results. Despite advances in 25(OH)D measurement, substantial variability in clinical laboratory 25(OH)D measurement persists. Existing guidelines have not used standardized data and, as a result, it seems unlikely that consensus regarding definitions of vitamin D deficiency, inadequacy, sufficiency, and excess will soon be reached. Until evidence-based consensus is reached, a reasonable clinical approach is advocated. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Synthesis of [123I]IBZM: a reliable procedure for routine clinical studies

    International Nuclear Information System (INIS)

    Zea-Ponce, Yolanda; Laruelle, Marc

    1999-01-01

    The single photon emission computed tomography (SPECT) D 2 /D 3 receptor radiotracer [ 123 I]IBZM, is prepared by electrophilic radioiodination of the precursor BZM with high-purity sodium [ 123 I]iodide in the presence of diluted peracetic acid. However, in our hands, the most commonly used procedure for this radiosynthesis produced variable and inconsistent labeling yields, to such extent that it became inappropriate for routine clinical studies. Our goal was to modify the labeling procedure, to obtain consistently better labeling and radiochemical yields. The best conditions found for the radioiodination were as follows: 50 μg precursor in 50 μL EtOH mixed with buffer pH 2; Na[ 123 I]I in 0.1 M NaOH ( 123 I]I solution the yields were consistent but lower. For example, for volumes between 417 and 523 μL the labeling yield was 61±5% (n=21), radiochemical yield was 56± 5% and radiochemical purity was 98±1%

  2. Evaluation of a commercial microarray as a confirmation test for the presence of extended-spectrum beta-lactamases in isolates from the routine clinical setting.

    NARCIS (Netherlands)

    Platteel, T.N.; Stuart, J.W.; Voets, G.M.; Scharringa, J.; Sande, N. van de; Fluit, A.C.; Leverstein-van Hall, M.A.; Sturm, P.D.J.; et al.,

    2011-01-01

    Since the diagnostic characteristics of the Check-KPC ESBL microarray as a confirmation test on isolates obtained in a routine clinical setting have not been determined, we evaluated the microarray in a random selection of 346 clinical isolates with a positive ESBL screen test (MIC >1 mg/L for

  3. Time lapse imaging: is it time to incorporate this technology into routine clinical practice?

    Science.gov (United States)

    Bhide, Priya; Maheshwari, Abha; Cutting, Rachel; Seenan, Susan; Patel, Anita; Khan, Khalid; Homburg, Roy

    2017-06-01

    Time-lapse imaging (TLI) systems for embryo incubation, assessment and selection are a novel technology available to in vitro fertilization (IVF) clinics. However, there is uncertainty about their clinical and cost-effectiveness and insufficient good quality evidence to warrant their routine use. Despite this, enthusiastic commercial marketing and slipping clinical equipoise have led to the widespread hasty introduction of this technology into practice, often at a considerable expense to the patient. We have reviewed the published literature and aim to summarize the strengths, weaknesses, opportunities and threats of these systems. These specialized incubators provide undisturbed embryo culture conditions and, by almost continuous monitoring of embryo development, generate morphokinetic parameters to aid embryo selection. They are thus hypothesized to improve outcomes following IVF. Although literature reports improved reproductive outcomes, these outcomes are largely surrogate and there is a paucity of studies reporting live births. The use of time lapse systems may reduce early pregnancy loss, increase elective single embryo transfers and limit multiple pregnancies through better embryo selection. However, the quality of the studies and hence the evidence so far, is low to moderate quality. We recommend further research producing robust high-quality evidence for and against the use of these systems.

  4. Benchmarking routine psychological services: a discussion of challenges and methods.

    Science.gov (United States)

    Delgadillo, Jaime; McMillan, Dean; Leach, Chris; Lucock, Mike; Gilbody, Simon; Wood, Nick

    2014-01-01

    Policy developments in recent years have led to important changes in the level of access to evidence-based psychological treatments. Several methods have been used to investigate the effectiveness of these treatments in routine care, with different approaches to outcome definition and data analysis. To present a review of challenges and methods for the evaluation of evidence-based treatments delivered in routine mental healthcare. This is followed by a case example of a benchmarking method applied in primary care. High, average and poor performance benchmarks were calculated through a meta-analysis of published data from services working under the Improving Access to Psychological Therapies (IAPT) Programme in England. Pre-post treatment effect sizes (ES) and confidence intervals were estimated to illustrate a benchmarking method enabling services to evaluate routine clinical outcomes. High, average and poor performance ES for routine IAPT services were estimated to be 0.91, 0.73 and 0.46 for depression (using PHQ-9) and 1.02, 0.78 and 0.52 for anxiety (using GAD-7). Data from one specific IAPT service exemplify how to evaluate and contextualize routine clinical performance against these benchmarks. The main contribution of this report is to summarize key recommendations for the selection of an adequate set of psychometric measures, the operational definition of outcomes, and the statistical evaluation of clinical performance. A benchmarking method is also presented, which may enable a robust evaluation of clinical performance against national benchmarks. Some limitations concerned significant heterogeneity among data sources, and wide variations in ES and data completeness.

  5. Adoption of routine telemedicine in Norway: the current picture

    Science.gov (United States)

    Zanaboni, Paolo; Knarvik, Undine; Wootton, Richard

    2014-01-01

    Background Telemedicine appears to be ready for wider adoption. Although existing research evidence is useful, the adoption of routine telemedicine in healthcare systems has been slow. Objective We conducted a study to explore the current use of routine telemedicine in Norway, at national, regional, and local levels, to provide objective and up-to-date information and to estimate the potential for wider adoption of telemedicine. Design A top-down approach was used to collect official data on the national use of telemedicine from the Norwegian Patient Register. A bottom-up approach was used to collect complementary information on the routine use of telemedicine through a survey conducted at the five largest publicly funded hospitals. Results Results show that routine telemedicine has been adopted in all health regions in Norway and in 68% of hospitals. Despite being widely adopted, the current level of use of telemedicine is low compared to the number of face-to-face visits. Examples of routine telemedicine can be found in several clinical specialties. Most services connect different hospitals in secondary care, and they are mostly delivered as teleconsultations via videoconference. Conclusions Routine telemedicine in Norway has been widely adopted, probably for geographical reasons, as in other settings. However, the level of use of telemedicine in Norway is rather low, and it has significant potential for further development as an alternative to face-to-face outpatient visits. This study is a first attempt to map routine telemedicine at regional, institutional, and clinical levels, and it provides useful information to understand the adoption of telemedicine in routine healthcare and to measure change in future updates. PMID:24433942

  6. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Walkup, Laura L. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States); Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States)

    2016-12-15

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  7. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    International Nuclear Information System (INIS)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J.; Walkup, Laura L.; Woods, Jason C.

    2016-01-01

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  8. Application of hormone receptor assay for clinical chemistry

    International Nuclear Information System (INIS)

    Sato, Seiya

    1978-01-01

    A conception of hormone receptors was explained to understand radioreceptor assay (RRA), and various problems in the operation of this method were described mainly. The principle of RRA is the same as that of RIA and CPBA, and measured values by RRA resembled to those by bioassay more closely than those by RIA. However, the sensitivity of RRA was inferior to that of RIA. It was important in using this method especially for measurement of peptide hormone not to deactivate biological the base by radioactivation. As the significance of this method in clinical chemistry, it was mentioned that this method was one kind of experiment to observe the biological activity of hormones, and that properties analysis of receptors, studies on action mechanism, the structure and function of hormone, the pathological analysis of endocrine abnormalities, and the development of drugs and treatment methods for receptors may become possible by this method. The other usefulness of this method was also mentioned. (Kanao, N.)

  9. Application of hormone receptor assay for clinical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Sato, S [Kitasato Univ. Hospital, Sagamihara, Kanagawa (Japan)

    1978-06-01

    A conception of hormone receptors was explained to understand radioreceptor assay (RRA), and various problems in the operation of this method were described mainly. The principle of RRA is the same as that of RIA and CPBA, and measured values by RRA resembled to those by bioassay more closely than those by RIA. However, the sensitivity of RRA was inferior to that of RIA. It was important in using this method especially for measurement of peptide hormone not to deactivate biological the base by radioactivation. As the significance of this method in clinical chemistry, it was mentioned that this method was one kind of experiment to observe the biological activity of hormones, and that properties analysis of receptors, studies on action mechanism, the structure and function of hormone, the pathological analysis of endocrine abnormalities, and the development of drugs and treatment methods for receptors may become possible by this method. The other usefulness of this method was also mentioned.

  10. Immunoassays in clinical chemistry (principles of immunoradiometric assays)

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    The use of antibodies as reagents in clinical chemistry for the quantitation of a wide range of analytes has now become widely established. Initially antibodies were employed in precipitation techniques, usually for the analysis of serum proteins, in solution or in the form of antibody containing gels, e.g. immunoprecipitation, immunodiffusion, and immunoelectrophoresis. Further developments have led to the highly sensitive techniques of radioimmunoassay and recently immunometric assay for the measurement of drugs, tumour markers and hormones. In general, those techniques without the addition of a label e.g. immunoprecipitation, immunodiffusion and immunoturbidimetry are the older techniques used for the measurement of serum proteins. These techniques are relatively insensitive, measuring at the g/L. level, and in the case of immunodiffusion are generally slow. Automation coupled with the development of chemistries to enhance precipitation has, however, reduced measurement times to minutes in modern laboratories. Nevertheless these methods have detection limits of the order of 1 g/L

  11. Routine hemoglobin electrophoresis for pediatric surgery day case ...

    African Journals Online (AJOL)

    Background: Hemoglobin electrophoresis (HBE) is a part of the preoperative routine requested by anesthetists. However, the prevalence of hemoglobinopathy in the population is low. This study aims to determine the clinical risk factors for hemoglobinopathies and propose clinical guidelines for preoperative screening of ...

  12. Highly accurate prediction of food challenge outcome using routinely available clinical data.

    Science.gov (United States)

    DunnGalvin, Audrey; Daly, Deirdre; Cullinane, Claire; Stenke, Emily; Keeton, Diane; Erlewyn-Lajeunesse, Mich; Roberts, Graham C; Lucas, Jane; Hourihane, Jonathan O'B

    2011-03-01

    Serum specific IgE or skin prick tests are less useful at levels below accepted decision points. We sought to develop and validate a model to predict food challenge outcome by using routinely collected data in a diverse sample of children considered suitable for food challenge. The proto-algorithm was generated by using a limited data set from 1 service (phase 1). We retrospectively applied, evaluated, and modified the initial model by using an extended data set in another center (phase 2). Finally, we prospectively validated the model in a blind study in a further group of children undergoing food challenge for peanut, milk, or egg in the second center (phase 3). Allergen-specific models were developed for peanut, egg, and milk. Phase 1 (N = 429) identified 5 clinical factors associated with diagnosis of food allergy by food challenge. In phase 2 (N = 289), we examined the predictive ability of 6 clinical factors: skin prick test, serum specific IgE, total IgE minus serum specific IgE, symptoms, sex, and age. In phase 3 (N = 70), 97% of cases were accurately predicted as positive and 94% as negative. Our model showed an advantage in clinical prediction compared with serum specific IgE only, skin prick test only, and serum specific IgE and skin prick test (92% accuracy vs 57%, and 81%, respectively). Our findings have implications for the improved delivery of food allergy-related health care, enhanced food allergy-related quality of life, and economized use of health service resources by decreasing the number of food challenges performed. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  13. Nondestructive assay instrument for measurement of plutonium in solutions

    International Nuclear Information System (INIS)

    Shirk, D.G.; Hsue, F.; Li, T.K.; Canada, T.R.

    1979-01-01

    A nondestructive assay (NDA) instrument that measures the 239 Pu content in solutions, using a passive gamma-ray spectroscopy technique, has been developed and installed in the LASL Plutonium Processing Facility. A detailed evaluation of this instrument has been performed. The results show that the instrument can routinely determine 239 Pu concentrations of 1 to 500 g/l with accuracies of 1 to 5% and assay times of 1 to 2 x 10 3 s

  14. A sensitive duplex nanoparticle-assisted PCR assay for identifying porcine epidemic diarrhea virus and porcine transmissible gastroenteritis virus from clinical specimens.

    Science.gov (United States)

    Zhu, Yu; Liang, Lin; Luo, Yakun; Wang, Guihua; Wang, Chunren; Cui, Yudong; Ai, Xia; Cui, Shangjin

    2017-02-01

    In this study, a novel duplex nanoparticle-assisted polymerase chain reaction (nanoPCR) assay was developed to detect porcine epidemic diarrhea virus (PEDV) and porcine transmissible gastroenteritis virus (TGEV). Two pairs of primers were designed based on the conserved region within the N gene of PEDV and TGEV. In a screening of 114 clinical samples from four provinces in China for PEDV and TGEV, 48.2 and 3.5 % of the samples, respectively, tested positive. Under optimized conditions, the duplex nanoPCR assay had a detection limit of 7.6 × 10 1 and 8.5 × 10 1 copies μL -1 for PEDV and TGEV, respectively. The sensitivity of the duplex nanoPCR assay was ten times higher than that of a conventional PCR assay. Moreover, no fragments were amplified when the duplex nanoPCR assay was used to test samples containing other porcine viruses. Our results indicate that the duplex nanoPCR assay described here is useful for the rapid detection of PEDV and TGEV and can be applied in clinical diagnosis.

  15. The radio ligand receptor assay for thyroid stimulating factors

    International Nuclear Information System (INIS)

    Kruck, G.; Kruck, I.

    1978-01-01

    The possible uses of RRA in routine examinations to detect HTSI and physiological TSH concentrations were investigated in this study. The primary difficulties were that the RRA had a low sensitivity using the Mehdi method and the investigation results exhibited large deviations. The authors first investigated the non-specific influences of the incubation medium such as temperature, incubation time, protein used and salts on the 125 I-TSH compared by means of the enriched membrane according to Mehdi. After the modification of the labelling process of 125 I-TSH with Smith's post-purification method, it was possible to improve the sensitivity of the assay system from 100 μU to 10 μU TSH/test. It was now possible to detect HTSI in 67% of the Morbus Basedow sera in clinical tests (compared with 54% in the RRA prior to modification and 19% in the McKenzie assay). The discrepancy between these results and those of Mukhtar et al. - with a HTSI detection in 100% of the cases investigated for the same sensitivity of the assay - remains unexplained. The sensitivity of the RRA is not sufficient to detect TSH in serum, as the standard region for the basal TSH level in the serum is given as between 0.5 and 3.8 μU/ml in the radioimmunoassay. (orig./AJ) [de

  16. Reduction of diabetes risk in routine clinical practice: are physical activity and nutrition interventions feasible and are the outcomes from reference trials replicable? A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Morrell Stephen L

    2010-10-01

    Full Text Available Abstract Background The clinical effectiveness of intensive lifestyle interventions in preventing or delaying diabetes in people at high risk has been established from randomised trials of structured, intensive interventions conducted in several countries over the past two decades. The challenge is to translate them into routine clinical settings. The objective of this review is to determine whether lifestyle interventions delivered to high-risk adult patients in routine clinical care settings are feasible and effective in achieving reductions in risk factors for diabetes. Methods Data sources: MEDLINE (PubMed, EMBASE, CINAHL, The Cochrane Library, Google Scholar, and grey literature were searched for English-language articles published from January 1990 to August 2009. The reference lists of all articles collected were checked to ensure that no relevant suitable studies were missed. Study selection: We included RCTs, before/after evaluations, cohort studies with or without a control group and interrupted time series analyses of lifestyle interventions with the stated aim of diabetes risk reduction or diabetes prevention, conducted in routine clinical settings and delivered by healthcare providers such as family physicians, practice nurses, allied health personnel, or other healthcare staff associated with a health service. Outcomes of interest were weight loss, reduction in waist circumference, improvement of impaired fasting glucose or oral glucose tolerance test (OGTT results, improvements in fat and fibre intakes, increased level of engagement in physical activity and reduction in diabetes incidence. Results Twelve from 41 potentially relevant studies were included in the review. Four studies were suitable for meta-analysis. A significant positive effect of the interventions on weight was reported by all study types. The meta-analysis showed that lifestyle interventions achieved weight and waist circumference reductions after one year

  17. Reduction of diabetes risk in routine clinical practice: are physical activity and nutrition interventions feasible and are the outcomes from reference trials replicable? A systematic review and meta-analysis.

    Science.gov (United States)

    Cardona-Morrell, Magnolia; Rychetnik, Lucie; Morrell, Stephen L; Espinel, Paola T; Bauman, Adrian

    2010-10-29

    The clinical effectiveness of intensive lifestyle interventions in preventing or delaying diabetes in people at high risk has been established from randomised trials of structured, intensive interventions conducted in several countries over the past two decades. The challenge is to translate them into routine clinical settings. The objective of this review is to determine whether lifestyle interventions delivered to high-risk adult patients in routine clinical care settings are feasible and effective in achieving reductions in risk factors for diabetes. MEDLINE (PubMed), EMBASE, CINAHL, The Cochrane Library, Google Scholar, and grey literature were searched for English-language articles published from January 1990 to August 2009. The reference lists of all articles collected were checked to ensure that no relevant suitable studies were missed. We included RCTs, before/after evaluations, cohort studies with or without a control group and interrupted time series analyses of lifestyle interventions with the stated aim of diabetes risk reduction or diabetes prevention, conducted in routine clinical settings and delivered by healthcare providers such as family physicians, practice nurses, allied health personnel, or other healthcare staff associated with a health service. Outcomes of interest were weight loss, reduction in waist circumference, improvement of impaired fasting glucose or oral glucose tolerance test (OGTT) results, improvements in fat and fibre intakes, increased level of engagement in physical activity and reduction in diabetes incidence. Twelve from 41 potentially relevant studies were included in the review. Four studies were suitable for meta-analysis. A significant positive effect of the interventions on weight was reported by all study types. The meta-analysis showed that lifestyle interventions achieved weight and waist circumference reductions after one year. However, no clear effects on biochemical or clinical parameters were observed, possibly

  18. Clinical evaluation of the 2nd generation radio-receptor assay for anti-thyrotropin receptor antibodies (TRAb) in Graves' disease

    International Nuclear Information System (INIS)

    Giovanella, L.; Ceriani, L.; Garancini, S.

    2002-01-01

    Full text: Detection of autoantibodies to the TSH receptor by radioreceptorial assays (RRA) is largely requested in clinical practice for the diagnosis of Graves' disease and its differentiation from diffuse thyroid autonomy. Additionally, TRAb measurement during antithyroid drug treatment can be useful to evaluate the risk of disease's relapse alter therapy discontinuation. Nevertheless, some patients affected by Graves' disease are TRAb negative when 1st generation assay is used. Recently a new RRA method for TRAb assay was developed by using human recombinant TSH-receptor and solid-phase technique. Aim of our work was the comparison between 1st and 2nd generation TRAb assays in Graves' disease patients and, particularly, the evaluation of 2nd generation test in a sub-group of patients affected by Graves' disease but with negative 1st generation TRAb assay. We evaluated the diagnostic performance of a newly developed 2nd generation TRAb assay (DYNOtest(r) TRAK human, BRAHMS Diagnostica GmbH, Germany) in 46 patients affected by Graves' disease with negative 1st generation TRAb assay (TRAK Assay(r), BRAHMS Diagnostica GmbH, Germany) . A control groups of 50 Graves' disease patients with positive 1st generation TRAb assay, 50 patients affected by Hashimoto's thyroiditis and 50 patients affected by nodular goiter were also examined. 41 out of 46 patients affected by Graves' disease with negative 1st generation TRAb assay showed a positive 2nd generation test. The overall sensitivity of the 2nd generation test was significantly improved respect the 1st generation assay in Graves' disease patients (χ 2 = 22.5, p<0.0001). 1 and 3 out of 50 patients affected by Hashimoto's thyroiditis were positive by 1st and 2nd generation TRAB assay, respectively. All these patients showed primary hypothyroidism. No differences resulted in euthyroid Hashimoto's thyroiditis sub-group and in nodular goiter control group. The 2nd generation TRAB assay is clearly more sensitive than the 1

  19. Clinical Application of a Multiplex Real-Time PCR Assay for Simultaneous Detection of Legionella Species, Legionella pneumophila, and Legionella pneumophila Serogroup 1

    OpenAIRE

    Benitez, Alvaro J.; Winchell, Jonas M.

    2014-01-01

    We developed a single-tube multiplex real-time PCR assay capable of simultaneously detecting and discriminating Legionella spp., Legionella pneumophila, and Legionella pneumophila serogroup 1 in primary specimens. Evaluation of 21 clinical specimens and 115 clinical isolates demonstrated this assay to be a rapid, high-throughput diagnostic test with 100% specificity that may aid during legionellosis outbreaks and epidemiologic investigations.

  20. Non-adherence in seniors with dementia - a serious problem of routine clinical practice.

    Science.gov (United States)

    Lužný, Jan; Ivanová, Kateřina; Juríčková, Lubica

    2014-01-01

    Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment - a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  1. Social Withdrawal Among Individuals Receiving Psychiatric Care: Derivation of a Scale Using Routine Clinical Assessment Data to Support Screening and Outcome Measurement.

    Science.gov (United States)

    Rios, Sebastian; Perlman, Christopher M

    2017-04-24

    Social withdrawal is a symptom experienced by individuals with an array of mental health conditions, particularly those with schizophrenia and mood disorders. Assessments of social withdrawal are often lengthy and may not be routinely integrated within the comprehensive clinical assessment of the individual. This study utilized item response and classical test theory methods to derive a Social Withdrawal Scale (SWS) using items embedded within a routine clinical assessment, the RAI-Mental Health (RAI-MH). Using data from 60,571 inpatients in Ontario, Canada, a common factor analysis identified seven items from the RAI-MH that measure social withdrawal. A graded response model found that six items had acceptable discrimination parameters: lack of motivation, reduced interaction, decreased energy, flat affect, anhedonia, and loss of interest. Summing these items, the SWS was found to have strong internal consistency (Cronbach's alpha = 0.82) and showed a medium to large effect size (d = 0.77) from admission to discharge. Fewer individuals with high SWS scores participated in social activity or reported having a confidant compared to those with lower scores. Since the RAI-MH is available across clinical subgroups in several jurisdictions, the SWS is a useful tool for screening, clinical decision support, and evaluation.

  2. Limited utility of routine surveillance imaging for classical Hodgkin lymphoma patients in first complete remission.

    Science.gov (United States)

    Pingali, Sai Ravi; Jewell, Sarah W; Havlat, Luiza; Bast, Martin A; Thompson, Jonathan R; Eastwood, Daniel C; Bartlett, Nancy L; Armitage, James O; Wagner-Johnston, Nina D; Vose, Julie M; Fenske, Timothy S

    2014-07-15

    The objective of this study was to compare the outcomes of patients with classical Hodgkin lymphoma (cHL) who achieved complete remission with frontline therapy and then underwent either clinical surveillance or routine surveillance imaging. In total, 241 patients who were newly diagnosed with cHL between January 2000 and December 2010 at 3 participating tertiary care centers and achieved complete remission after first-line therapy were retrospectively analyzed. Of these, there were 174 patients in the routine surveillance imaging group and 67 patients in the clinical surveillance group, based on the intended mode of surveillance. In the routine surveillance imaging group, the intended plan of surveillance included computed tomography and/or positron emission tomography scans; whereas, in the clinical surveillance group, the intended plan of surveillance was clinical examination and laboratory studies, and scans were obtained only to evaluate concerning signs or symptoms. Baseline patient characteristics, prognostic features, treatment records, and outcomes were collected. The primary objective was to compare overall survival for patients in both groups. For secondary objectives, we compared the success of second-line therapy and estimated the costs of imaging for each group. After 5 years of follow-up, the overall survival rate was 97% (95% confidence interval, 92%-99%) in the routine surveillance imaging group and 96% (95% confidence interval, 87%-99%) in the clinical surveillance group (P = .41). There were few relapses in each group, and all patients who relapsed in both groups achieved complete remission with second-line therapy. The charges associated with routine surveillance imaging were significantly higher than those for the clinical surveillance strategy, with no apparent clinical benefit. Clinical surveillance was not inferior to routine surveillance imaging in patients with cHL who achieved complete remission with frontline therapy. Routine

  3. Psychometric properties of the Spanish version of the Clinical Outcomes in Routine Evaluation – Outcome Measure

    Directory of Open Access Journals (Sweden)

    Trujillo A

    2016-06-01

    Full Text Available Adriana Trujillo,1,2 Guillem Feixas,1,2 Arturo Bados,1 Eugeni García-Grau,1 Marta Salla,1 Joan Carles Medina,1 Adrián Montesano,1,2 José Soriano,3 Leticia Medeiros-Ferreira,4 Josep Cañete,5 Sergi Corbella,6 Antoni Grau,7 Fernando Lana,8 Chris Evans9 1Department of Personality, Assessment and Psychological Treatments, Faculty of Psychology, 2Institute for Brain, Cognition and Behaviour, University of Barcelona, 3Hospital of the Holy Cross and Saint Paul, 4Nou Barris Mental Health Center, Barcelona, 5Hospital of Mataró, Sanitary Consortium of Maresme, Mataró, 6FPCEE, Blanquerna, Universitat Ramon Llull, 7Institute of Eating Disorders, Barcelona, 8MAR Health Park, CAEMIL, Santa Coloma de Gramenet, Spain; 9East London NHS Foundation Trust, NPDDNet, London, UK Objective: The objective of this paper is to assess the reliability and validity of the Spanish translation of the Clinical Outcomes in Routine Evaluation – Outcome Measure, a 34-item self-report questionnaire that measures the client’s status in the domains of Subjective well-being, Problems/Symptoms, Life functioning, and Risk.Method: Six hundred and forty-four adult participants were included in two samples: the clinical sample (n=192 from different mental health and primary care centers; and the nonclinical sample (n=452, which included a student and a community sample.Results: The questionnaire showed good acceptability and internal consistency, appropriate test–retest reliability, and acceptable convergent validity. Strong differentiation between clinical and nonclinical samples was found. As expected, the Risk domain had different characteristics than other domains, but all findings were comparable with the UK referential data. Cutoff scores were calculated for clinical significant change assessment.Conclusion: The Spanish version of the Clinical Outcomes in Routine Evaluation – Outcome Measure showed acceptable psychometric properties, providing support for using the

  4. A clinical evaluation of placental growth factor in routine practice in high-risk women presenting with suspected pre-eclampsia and/or fetal growth restriction.

    Science.gov (United States)

    Ormesher, L; Johnstone, E D; Shawkat, E; Dempsey, A; Chmiel, C; Ingram, E; Higgins, L E; Myers, J E

    2018-03-13

    To evaluate the use of plasma Placental Growth Factor (PlGF), recommended by the recent NICE guidance, in women with suspected pre-eclampsia (PE) and/or fetal growth restriction (FGR). Non-randomised prospective clinical evaluation study in high-risk antenatal clinics in a tertiary maternity unit. PlGF testing was performed in addition to routine clinical assessment in 260 women >20 weeks' gestation with chronic disease (hypertension, renal disease ± diabetes) with a change in maternal condition or in women with suspected FGR to determine the impact on clinical management. Results were revealed and standardised care pathways followed. Outcome of pregnancies with a low PlGF (women had an adverse outcome (PE/birthweight women with PlGF 14 days. The PlGF result altered clinical management (surveillance or timing of birth) in 196/260 (75.4%) cases. Alternative PlGF thresholds did not significantly improve diagnostic performance. Our evaluation confirms the value of PlGF as a diagnostic tool for placental dysfunction. However, low PlGF in isolation should not trigger iatrogenic delivery. Further research linking placental pathology, maternal disease and maternal PlGF levels is urgently needed before this test can be implemented in routine clinical practice. Copyright © 2018. Published by Elsevier B.V.

  5. The impact of introducing intensity modulated radiotherapy into routine clinical practice.

    Science.gov (United States)

    Miles, Elizabeth A; Clark, Catharine H; Urbano, M Teresa Guerrero; Bidmead, Margaret; Dearnaley, David P; Harrington, Kevin J; A'Hern, Roger; Nutting, Christopher M

    2005-12-01

    Intensity modulated radiotherapy (IMRT) at the Royal Marsden Hospital London was introduced in July 2001. Treatment delivery was dynamic using a single-phase technique. Concerns were raised regarding increased clinical workload due to introduction of new technology. The potential increased use of resources was assessed. IMRT patient selection was within guidelines of clinical trials and included patients undergoing prostate plus pelvic lymph node (PPN) irradiation and head and neck cancer (HNC) treatment. Patient planning, quality assurance and treatment times were collected for an initial IMRT patient group. A comparative group of patients with advanced HNC undergoing two- or three-phase conventional radiotherapy, requiring matched photon and electron fields, were also timed. The median overall total planning time for IMRT was greater for HNC patients compared to the PPN cohort. For HNC the overall IMRT planning time was significantly longer than for conventional. The median treatment time for conventional two- or three-phase HNC treatments, encompassing similar volumes to those treated with IMRT, was greater than that for the IMRT HNC patient cohort. A reduction in radiographer man hours per patient of 4.8h was recorded whereas physics time was increased by 4.9h per patient. IMRT currently increases overall planning time. Additional clinician input is required for target volume localisation. Physics time is increased, a significant component of this being patient specific QA. Radiographer time is decreased. For HNC a single phase IMRT treatment has proven to be more efficient than a multiple phase conventional treatment. IMRT has been integrated smoothly and efficiently into the existing treatment working day. This preliminary study suggests that IMRT could be a routine treatment with efficient use of current radiotherapy resources.

  6. Chromogenic assay for BAY 81-8973 potency assignment has no impact on clinical outcome or monitoring in patient samples.

    Science.gov (United States)

    Kitchen, S; Katterle, Y; Beckmann, H; Maas Enriquez, M

    2016-06-01

    Essentials Discrepancies can exist in factor VIII activity measured by the one-stage or chromogenic assays. LEOPOLD trial data were used to assess clinical impact of BAY 81-8973 potency assignment assay. Efficacy was not affected by the assay used for potency assignment and dosing of BAY 81-8973. Either assay may be used to measure factor VIII activity after BAY 81-8973 infusion. Background Product-specific discrepancies have been reported for factor VIII (FVIII) activity determined with one-stage or chromogenic assays. Objective To assess the clinical impact of potency assignment of BAY 81-8973, a full-length, unmodified, recombinant human FVIII, by use of the chromogenic assay or chromogenic assay adjusted to mimic results obtained with the one-stage assay Patients/methods Patients aged 12-65 years with severe hemophilia A received BAY 81-8973 in LEOPOLD I (20-50 IU kg(-1) two or three times weekly [investigator decision]) and LEOPOLD II (randomized to 20-30 IU kg(-1) twice weekly, 30-40 IU kg(-1) three times weekly, or on-demand treatment). Both trials included two 6-month crossover periods in which potency labeling was determined with the chromogenic substrate assay as per the European Pharmacopoeia (CS/EP) or the chromogenic substrate assay adjusted to mimic results obtained with the one-stage assay (CS/ADJ). The annualized bleeding rate (ABR) and FVIII incremental recovery were assessed by the use of pooled data. Results The analysis was perfomed on 121 patients. Median (quartile [Q] 1; Q3) ABRs during the CS/EP and CS/ADJ periods were 1.98 (0; 5.92) and 1.98 (0; 7.34), respectively. The mean incremental recovery was > 2 IU dL(-1) per IU kg(-1) in both periods with the use of either assay for postinfusion FVIII measurements. The median (Q1; Q3) chromogenic/one-stage assay recovery ratio was 1.054 (0.892; 1.150) for the CS/EP period when a plasma standard was used for calibration. Conclusions No impact on the ABR was observed with chromogenic-based as compared

  7. Analytical performances of a new enzymatic assay for hemoglobin A1c.

    Science.gov (United States)

    Jaisson, Stéphane; Desmons, Aurore; Renard, Benoît; Chevelle, Benjamin; Leroy, Nathalie; Gillery, Philippe

    2014-07-01

    HbA1c is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA1c by a fructosyl dipeptide oxidase using Architect analyzers. Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA1c measurement have been evaluated. Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA1c [Architect, mmol/mol]=0.986×HbA1c [Variant II, mmol/mol]+0.713 (r=0.998, n=109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA1c assays (i.e. labile HbA1c, carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA1c quantification by this method. This new enzymatic assay proved to be a robust and reliable method for HbA1c measurement suitable for routine practice in clinical chemistry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Integrated sample-to-detection chip for nucleic acid test assays.

    Science.gov (United States)

    Prakash, R; Pabbaraju, K; Wong, S; Tellier, R; Kaler, K V I S

    2016-06-01

    Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.

  9. Process mining routinely collected electronic health records to define real-life clinical pathways during chemotherapy.

    Science.gov (United States)

    Baker, Karl; Dunwoodie, Elaine; Jones, Richard G; Newsham, Alex; Johnson, Owen; Price, Christopher P; Wolstenholme, Jane; Leal, Jose; McGinley, Patrick; Twelves, Chris; Hall, Geoff

    2017-07-01

    There is growing interest in the use of routinely collected electronic health records to enhance service delivery and facilitate clinical research. It should be possible to detect and measure patterns of care and use the data to monitor improvements but there are methodological and data quality challenges. Driven by the desire to model the impact of a patient self-test blood count monitoring service in patients on chemotherapy, we aimed to (i) establish reproducible methods of process-mining electronic health records, (ii) use the outputs derived to define and quantify patient pathways during chemotherapy, and (iii) to gather robust data which is structured to be able to inform a cost-effectiveness decision model of home monitoring of neutropenic status during chemotherapy. Electronic Health Records at a UK oncology centre were included if they had (i) a diagnosis of metastatic breast cancer and received adjuvant epirubicin and cyclosphosphamide chemotherapy or (ii) colorectal cancer and received palliative oxaliplatin and infusional 5-fluorouracil chemotherapy, and (iii) were first diagnosed with cancer between January 2004 and February 2013. Software and a Markov model were developed, producing a schematic of patient pathways during chemotherapy. Significant variance from the assumed care pathway was evident from the data. Of the 535 patients with breast cancer and 420 with colorectal cancer there were 474 and 329 pathway variants respectively. Only 27 (5%) and 26 (6%) completed the planned six cycles of chemotherapy without having unplanned hospital contact. Over the six cycles, 169 (31.6%) patients with breast cancer and 190 (45.2%) patients with colorectal cancer were admitted to hospital. The pathways of patients on chemotherapy are complex. An iterative approach to addressing semantic and data quality issues enabled the effective use of routinely collected patient records to produce accurate models of the real-life experiences of chemotherapy patients and

  10. Quality control of estrogen receptor assays.

    Science.gov (United States)

    Godolphin, W; Jacobson, B

    1980-01-01

    Four types of material have been used for the quality control of routine assays of estrogen receptors in human breast tumors. Pieces of hormone-dependent Nb rat mammary tumors gave a precision about 40%. Rat uteri and rat tumors pulverized at liquid nitrogen temperature and stored as powder yielded precision about 30%. Powdered and lyophilised human tumors appear the best with precision as good as 17%.

  11. A novel enterovirus and parechovirus multiplex one-step real-time PCR-validation and clinical experience.

    Science.gov (United States)

    Nielsen, Alex Christian Yde; Böttiger, Blenda; Midgley, Sofie Elisabeth; Nielsen, Lars Peter

    2013-11-01

    As the number of new enteroviruses and human parechoviruses seems ever growing, the necessity for updated diagnostics is relevant. We have updated an enterovirus assay and combined it with a previously published assay for human parechovirus resulting in a multiplex one-step RT-PCR assay. The multiplex assay was validated by analysing the sensitivity and specificity of the assay compared to the respective monoplex assays, and a good concordance was found. Furthermore, the enterovirus assay was able to detect 42 reference strains from all 4 species, and an additional 9 genotypes during panel testing and routine usage. During 15 months of routine use, from October 2008 to December 2009, we received and analysed 2187 samples (stool samples, cerebrospinal fluids, blood samples, respiratory samples and autopsy samples) were tested, from 1546 patients and detected enteroviruses and parechoviruses in 171 (8%) and 66 (3%) of the samples, respectively. 180 of the positive samples could be genotyped by PCR and sequencing and the most common genotypes found were human parechovirus type 3, echovirus 9, enterovirus 71, Coxsackievirus A16, and echovirus 25. During 2009 in Denmark, both enterovirus and human parechovirus type 3 had a similar seasonal pattern with a peak during the summer and autumn. Human parechovirus type 3 was almost invariably found in children less than 4 months of age. In conclusion, a multiplex assay was developed allowing simultaneous detection of 2 viruses, which can cause similar clinical symptoms. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Training clinicians in how to use patient-reported outcome measures in routine clinical practice.

    Science.gov (United States)

    Santana, Maria J; Haverman, Lotte; Absolom, Kate; Takeuchi, Elena; Feeny, David; Grootenhuis, Martha; Velikova, Galina

    2015-07-01

    Patient-reported outcome measures (PROs) were originally developed for comparing groups of people in clinical trials and population studies, and the results were used to support treatment recommendations or inform health policy, but there was not direct benefit for the participants providing PROs data. However, as the experience in using those measures increased, it became obvious the clinical value in using individual patient PROs profiles in daily practice to identify/monitor symptoms, evaluate treatment outcomes and support shared decision-making. A key issue limiting successful implementation is clinicians' lack of knowledge on how to effectively utilize PROs data in their clinical encounters. Using a change management theoretical framework, this paper describes the development and implementation of three programs for training clinicians to effectively use PRO data in routine practice. The training programs are in three diverse clinical areas (adult oncology, lung transplant and paediatrics), in three countries with different healthcare systems, thus providing a rare opportunity to pull out common approaches whilst recognizing specific settings. For each program, we describe the clinical and organizational setting, the program planning and development, the content of the training session with supporting material, subsequent monitoring of PROs use and evidence of adoption. The common successful components and practical steps are identified, leading to discussion and future recommendations. The results of the three training programs are described as the implementation. In the oncology program, PRO data have been developed and are currently evaluated; in the lung transplant program, PRO data are used in daily practice and the integration with electronic patient records is under development; and in the paediatric program, PRO data are fully implemented with around 7,600 consultations since the start of the implementation. Adult learning programs teaching clinicians

  13. Chromosome aberration assays in Allium

    Energy Technology Data Exchange (ETDEWEB)

    Grant, W.F.

    1982-01-01

    The common onion (Allium cepa) is an excellent plant for the assay of chromosome aberrations after chemical treatment. Other species of Allium (A. cepa var. proliferum, A. carinatum, A. fistulosum and A. sativum) have also been used but to a much lesser extent. Protocols have been given for using root tips from either bulbs or seeds of Allium cepa to study the cytological end-points, such as chromosome breaks and exchanges, which follow the testing of chemicals in somatic cells. It is considered that both mitotic and meiotic end-points should be used to a greater extent in assaying the cytogenetic effects of a chemical. From a literature survey, 148 chemicals are tabulated that have been assayed in 164 Allium tests for their clastogenic effect. Of the 164 assays which have been carried out, 75 are reported as giving a positive reaction, 49 positive and with a dose response, 1 positive and temperature-related, 9 borderline positive, and 30 negative; 76% of the chemicals gave a definite positive response. It is proposed that the Allium test be included among those tests routinely used for assessing chromosomal damage induced by chemicals.

  14. Gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of Japanese encephalitis virus

    International Nuclear Information System (INIS)

    Huang, S-H; Tsai, M-H; Lin, C-W; Yang, T-C; Chuang, P-H; Tsai, I-S; Lu, H-C; Wan Lei; Lin, Y-J; Lai, C-H

    2008-01-01

    Virus isolation and antibody detection are routinely used for diagnosis of Japanese encephalitis virus (JEV) infection, but the low level of transient viremia in some JE patients makes JEV isolation from clinical and surveillance samples very difficult. We describe the use of gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of JEV from its RNA genome. We tested the effect of gold nanoparticles on four different PCR systems, including conventional PCR, reverse-transcription PCR (RT-PCR), and SYBR green real-time PCR and RT-PCR assays for diagnosis in the acute phase of JEV infection. Gold nanoparticles increased the amplification yield of the PCR product and shortened the PCR time compared to the conventional reaction. In addition, nanogold-based real-time RT-PCR showed a linear relationship between Ct and template amount using ten-fold dilutions of JEV. The nanogold-based RT-PCR and real-time quantitative RT-PCR assays were able to detect low levels (1-10 000 copies) of the JEV RNA genomes extracted from culture medium or whole blood, providing early diagnostic tools for the detection of low-level viremia in the acute-phase infection. The assays described here were simple, sensitive, and rapid approaches for detection and quantitation of JEV in tissue cultured samples as well as clinical samples

  15. Routine use of point-of-care tests: usefulness and application in clinical microbiology.

    Science.gov (United States)

    Clerc, O; Greub, G

    2010-08-01

    Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

  16. Routine administration of standardized questionnaires that assess aspects of patients quality of life in medical oncology clinics: A systematic review

    International Nuclear Information System (INIS)

    Alsaleh, Kh.

    2013-01-01

    Purpose: Increasing interest in the Quality of Life outcomes in cancer patients led to increase implementation of their use in routine clinical practice. The aim of this systemic review is to review the scientific evidence behind recommending the use of quality of life (QoL) scales routinely in outpatient evaluation. Methods: Systematic review for all published randomized controlled trials in English language between January 1, 1990 till December 31, 2012. Out of 487 articles (476 identified by electronic search + 11 articles identified by manual search), six trials satisfied the eligibility criteria: (1) the study was a randomized controlled trial (RCT) with randomization of patients or health care providers; (2) the findings of the administered questionnaire or scale (the intervention) were given to health care provider, and compared to standard care with no questionnaire administered (the control); (3) study was conducted in outpatient oncology clinics; and (4) an outcome was measured that related to (i) QoL improvement, (ii) reduction in morbidity, (iii) reduction in stress for the patients, (iv) improvement in communication between patients and health care provider, or (v) improved patient satisfaction. Assessment for the quality of the study was done using the GRADE methodology. Results: Serious methodological issues were affecting most of the trials. Overall the evaluation of the quality of the evidence from these identified trials suggests that there is a weak recommendation to use QoL scales in routine oncology practice to improve communication between physicians and patients. Conclusion: The routine use of such tools in the outpatient settings at improving the patient outcome or satisfaction cannot be recommended based on the available evidence. The potential harm with the excess use of resources needed to implement, collect, store, analyse, and present such data to health care providers should be also considered. Further research and better designed

  17. A high-throughput assay of NK cell activity in whole blood and its clinical application

    International Nuclear Information System (INIS)

    Lee, Saet-byul; Cha, Junhoe; Kim, Im-kyung; Yoon, Joo Chun; Lee, Hyo Joon; Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan; Lee, Jae Myun; Lee, Kang Young; Kim, Jongsun

    2014-01-01

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as 51 Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer

  18. A high-throughput assay of NK cell activity in whole blood and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Saet-byul [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Cha, Junhoe [ATGen Co. Ltd., Sungnam (Korea, Republic of); Kim, Im-kyung [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoon, Joo Chun [Department of Microbiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Lee, Hyo Joon [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan [ATGen Co. Ltd., Sungnam (Korea, Republic of); Lee, Jae Myun [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Kang Young, E-mail: kylee117@yuhs.ac [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jongsun, E-mail: jkim63@yuhs.ac [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-14

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as {sup 51}Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer.

  19. Clinical evaluation of a helicase-dependant amplification (HDA)-based commercial assay for the simultaneous detection of HSV-1 and HSV-2.

    Science.gov (United States)

    Teo, Jeanette W P; Chiang, Donald; Jureen, Roland; Lin, Raymond T P

    2015-11-01

    In this study, we evaluate the performance of a commercial assay, the AmpliVue HSV 1+2 Assay (Quidel), which employs HDA for the detection of both HSV-1 and HSV-2. The assay was tested on 307 clinical specimens (genital, oral, and dermal). When compared to shell vial virus culture and immunofluorescence typing of HSV, the positive percent agreement and negative percent agreement values were 98.2% and 90.9%, respectively. Excellent assay performance was demonstrated. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Development and evaluation of a nested-PCR assay for Senecavirus A diagnosis.

    Science.gov (United States)

    Feronato, Cesar; Leme, Raquel A; Diniz, Jaqueline A; Agnol, Alais Maria Dall; Alfieri, Alice F; Alfieri, Amauri A

    2018-02-01

    Senecavirus A (SVA) has been associated with vesicular disease in weaned and adult pigs and with high mortality of newborn piglets. This study aimed to establish a nested-PCR assay for the routine diagnosis of SVA infection. Tissue samples (n = 177) were collected from 37 piglets of 18 pig farms located in four different Brazilian states. For the nested-PCR, a primer set was defined to amplify an internal VP1 fragment of 316 bp of SVA genome. Of the 37 piglets, 15 (40.5%) and 23 (62.2%) were positive for the SVA in the RT-PCR and nested-PCR assays, respectively. The SVA RNA was detected in 61/177 (34.5%) samples with the RT-PCR, while the nested-PCR assay showed 84/177 (47.5%) samples with the virus (p PCR and nested-PCR assays, respectively. Nucleotide sequencing analysis revealed similarities of 98.7-100% among SVA Brazilian strains and of 86.6-98% with SVA strains from other countries. The nested-PCR assay in this study was suitable to recover the SVA RNA in biological specimens, piglets, and/or herds that were considered as negative in the RT-PCR assay, and is proposed for the routine investigation of the SVA infection in piglets, especially when other techniques are not available or when a great number of samples has to be examined.

  1. Comparison of the analytical and clinical performances of Abbott RealTime High Risk HPV, Hybrid Capture 2, and DNA Chip assays in gynecology patients.

    Science.gov (United States)

    Park, Seungman; Kang, Youjin; Kim, Dong Geun; Kim, Eui-Chong; Park, Sung Sup; Seong, Moon-Woo

    2013-08-01

    The detection of high-risk (HR) HPV in cervical cancer screening is important for early diagnosis of cervical cancer or pre-cancerous lesions. We evaluated the analytical and clinical performances of 3 HR HPV assays in Gynecology patients. A total of 991 specimens were included in this study: 787 specimens for use with a Hybrid Capture 2 (HC2) and 204 specimens for a HPV DNA microarray (DNA Chip). All specimens were tested using an Abbott RealTime High Risk HPV assay (Real-time HR), PGMY PCR, and sequence analysis. Clinical sensitivities for severe abnormal cytology (severe than high-grade squamous intraepithelial lesion) were 81.8% for Real-time HR, 77.3% for HC2, and 66.7% for DNA Chip, and clinical sensitivities for severe abnormal histology (cervical intraepithelial neoplasia grade 2+) were 91.7% for HC2, 87.5% for Real-time HR, and 73.3% for DNA Chip. As compared to results of the sequence analysis, HC2, Real-time HR, and DNA Chip showed concordance rates of 94.3% (115/122), 90.0% (117/130), and 61.5% (16/26), respectively. The HC2 assay and Real-time HR assay showed comparable results to each other in both clinical and analytical performances, while the DNA Chip assay showed poor clinical and analytical performances. The Real-time HR assay can be a good alternative option for HR HPV testing with advantages of allowing full automation and simultaneous genotyping of HR types 16 and 18. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Field-Deployable Reverse Transcription-Insulated Isothermal PCR (RT-iiPCR) Assay for Rapid and Sensitive Detection of Foot-and-Mouth Disease Virus.

    Science.gov (United States)

    Ambagala, A; Fisher, M; Goolia, M; Nfon, C; Furukawa-Stoffer, T; Ortega Polo, R; Lung, O

    2017-10-01

    Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hoofed animals, which can decimate the livestock industry and economy of countries previously free of this disease. Rapid detection of foot-and-mouth disease virus (FMDV) is critical to containing an FMD outbreak. Availability of a rapid, highly sensitive and specific, yet simple and field-deployable assay would support local decision-making during an FMDV outbreak. Here we report validation of a novel reverse transcription-insulated isothermal PCR (RT-iiPCR) assay that can be performed on a commercially available, compact and portable POCKIT ™ analyser that automatically analyses data and displays '+' or '-' results. The FMDV RT-iiPCR assay targets the 3D region of the FMDV genome and was capable of detecting 9 copies of in vitro-transcribed RNA standard with 95% confidence. It accurately identified 63 FMDV strains belonging to all seven serotypes and showed no cross-reactivity with viruses causing similar clinical diseases in cloven-hoofed animals. The assay was able to identify FMDV RNA in multiple sample types including oral, nasal and lesion swabs, epithelial tissue suspensions, vesicular and oral fluid samples, even before the appearance of clinical signs. Clinical sensitivity of the assay was comparable or slightly higher than the laboratory-based real-time RT-PCR assay in use. The assay was able to detect FMDV RNA in vesicular fluid samples without nucleic acid extraction. For RNA extraction from more complex sample types, a commercially available taco ™ mini transportable magnetic bead-based, automated extraction system was used. This assay provides a potentially useful field-deployable diagnostic tool for rapid detection of FMDV in an outbreak in FMD-free countries or for routine diagnostics in endemic countries with less structured laboratory systems. © 2016 Her Majesty the Queen in Right of Canada.

  3. Comparison of real-time and quantitative polymerase chain reaction assays in detection of cytomegalovirus DNA in clinical specimens

    International Nuclear Information System (INIS)

    Gokahmetoglu, S.; Deniz, E.

    2007-01-01

    To compare the real-time (RT) and qualitative (Q) polymerase chain reaction (PCR) assays for detection of Cytomegalovirus (CMV) DNA. The study took place in the Department of Microbiology, Erciyes University, Kayseri and in Iontek Laboratory, Istanbul, Turkey, from August to December 2006. One hundred and seven clinical specimens from 67 patients were included in the study. Cytomegalovirus DNA was investigated using RT-PCR kit (Fluorion Iontek, Turkey) and Q-PCR kit (Fluorion Iontek, Turkey). Deoxyribonucleic acid sequencing was applied to the samples that yielded discrepant results in both assays. Mac Nema's Chi Square test was used for statistical analysis. Of the specimens, 27 were found positive with both assays: 9 with only RT-PCR, and 11 with only Q-PCR assay. Both assays were found negative in 60 of the specimens. There was a good agreement between the 2 assays in 87(81.3%) of the specimens. There was no statistical significant difference between the assays (p>0.05). Two of the 11 samples that RT-PCR negative Q-PCR positive, and 3 of 9 samples that RT-PCR positive Q-PCR negative were found to be CMV DNA positive by DNA sequencing. A good level of concordance between RT-PCR and Q-PCR assays for CMV DNA detection has been found. (author)

  4. Cardiac troponins--Translational biomarkers in cardiology: Theory and practice of cardiac troponin high-sensitivity assays.

    Science.gov (United States)

    Adamcova, Michaela; Popelova-Lencova, Olga; Jirkovsky, Eduard; Simko, Fedor; Gersl, Vladimir; Sterba, Martin

    2016-01-01

    Tn is a unique translational biomarker in cardiology whose potential has not been diminished in the new era of high sensitive assays. cTns can be valuable markers in cardiac diseases as well as in infectious diseases and respiratory diseases. Furthermore, the role of cTns is growing in the routine evaluation of cardioxicity and in determining the efficacy/safety ratio of novel cardioprotective strategies in clinical settings. cTns can detect myocardial injury not only in a wide spectrum of laboratory animals in experimental studies in vivo, but also in isolated heart models or cardiomyocytes in vitro. The crucial issue regarding the cross-species usage of cardiac troponin investigation remains the choice of cardiac troponin testing. This review summarizes the recent proteomic data on aminoacid sequences of cTnT and cTnI in various species, as well as selected analytical characteristics of human cardiac troponin high-sensitivity assays. Due to the highly phylogenetically conserved structure of troponins, the same bioindicator can be investigated using the same method in both clinical and experimental cardiology, thus contributing to a better understanding of the pathogenesis of cardiac diseases as well as to increased effectiveness of troponin use in clinical practice. Measuring cardiac troponins using commercially available human high-sensitivity cardiac troponin tests with convenient antibodies selected on the basis of adequate proteomic knowledge can solve many issues which would otherwise be difficult to address in clinical settings for various ethical and practical reasons. Our survey could help elaborate the practical guidelines for optimizing the choice of cTns assay in cardiology. © 2016 International Union of Biochemistry and Molecular Biology.

  5. [Big data from clinical routine].

    Science.gov (United States)

    Mansmann, U

    2018-04-01

    Over the past 100 years, evidence-based medicine has undergone several fundamental changes. Through the field of physiology, medical doctors were introduced to the natural sciences. Since the late 1940s, randomized and epidemiological studies have come to provide the evidence for medical practice, which led to the emergence of clinical epidemiology as a new field in the medical sciences. Within the past few years, big data has become the driving force behind the vision for having a comprehensive set of health-related data which tracks individual healthcare histories and consequently that of large populations. The aim of this article is to discuss the implications of data-driven medicine, and to examine how it can find a place within clinical care. The EU-wide discussion on the development of data-driven medicine is presented. The following features and suggested actions were identified: harmonizing data formats, data processing and analysis, data exchange, related legal frameworks and ethical challenges. For the effective development of data-driven medicine, pilot projects need to be conducted to allow for open and transparent discussion on the advantages and challenges. The Federal Ministry of Education and Research ("Bundesministerium für Bildung und Forschung," BMBF) Arthromark project is an important example. Another example is the Medical Informatics Initiative of the BMBF. The digital revolution affects clinic practice. Data can be generated and stored in quantities that are almost unimaginable. It is possible to take advantage of this for development of a learning healthcare system if the principles of medical evidence generation are integrated into innovative IT-infrastructures and processes.

  6. Routine clinical use of radiopharmaceuticals in Latin American developing countries

    International Nuclear Information System (INIS)

    Mitta, A.E.

    1985-01-01

    The paper describes the routine clinical use of radiopharmaceuticals in the developing countries of Latin America made possible by: (1) the International Atomic Energy Agency (IAEA), which sent experts and equipment to many countries and made a substantial bibliographic contribution on the subject; (2) the Latin American Association of Societies of Nuclear Biology and Medicine (ALASBIMN), which fostered the exchange of data on techniques of radiopharmaceutical preparation and quality control by providing materials for tests, etc., and by publishing quality control manuals in some countries, finally in 1982 producing the Manual of Radiopharmaceutical Quality Control, in collaboration with the Inter-American Nuclear Energy Commission (CIEN) and published by the Organization of American States (OAS); (3) the countries themselves under agreements between their atomic energy commissions; (4) radiopharmacy courses organized by universities, either alone or in collaboration with the IAEA, WHO, etc.; (5) professional workers who established radiopharmaceutical services at private centres. Finally, the societies of nuclear medicine and biology in each country, the World Federation of Nuclear Medicine and Biology, the ALASBIMN, the IAEA, etc. organized symposia and meetings which afforded opportunities to professionals of these countries to receive and exchange information, since in Latin America, given its language and human characteristics, the problems are similar. The countries referred to are Argentina, Brazil, Mexico, Uruguay, Bolivia, Paraguay, Chile, Peru, Ecuador, Colombia, Venezuela, Costa Rica, Guatemala, Puerto Rico, El Salvador and Panama; little is known about Honduras, Nicaragua, the Dominican Republic and Cuba. (author)

  7. Clinical and analytical performance of the BD Onclarity™ HPV assay for detection of CIN2+ lesions on SurePath samples

    DEFF Research Database (Denmark)

    Ejegod, Ditte Møller; Junge, Jette; Franzmann, Maria

    2016-01-01

    BACKGROUND: The novel BD Onclarity(TM) HPV assay (Onclarity) on the BD Viper™ LT system (BD Diagnostics, Sparks, MD), detects E6/E7 DNA from 13 high-risk HPV genotypes and HPV66. We compared the analytical and clinical performance of the Onclarity Assay to that of Hybrid Capture 2 and LINEAR ARRAY...

  8. Development and Validation of the Pediatric Diabetes Routines Questionnaire for Adolescents.

    Science.gov (United States)

    Pierce, Jessica S; Jordan, Sara S; Arnau, Randolph C

    2018-04-06

    This study describes the development and psychometric evaluation of an adolescent self-report version of the Pediatric Diabetes Routines Questionnaire (PDRQ:A), a measure of diabetes-specific routines for youth with type 1 diabetes, and further validation of the parent-version (PDRQ:P) in an adolescent sample. Participants included 120 parent-adolescent dyads (ages 12-17) and an additional 24 parents who completed measures of diabetes-specific adolescent routines, general adolescent routines, diabetes self-care, and family support of youth diabetes care. The PDRQ:P/A demonstrated good internal consistency, test-retest reliability, and parent-child agreement, and adequate validity coefficients. Confirmatory factor analysis supported a one-factor model. Promising results were obtained. The PDRQ:P/A is a clinically feasible parent- and self-report measure that can provide valuable information regarding how frequently adolescents engage in their diabetes management tasks in a consistent manner. Addition of an adolescent report format will enhance the utility of the measure for clinical and research use.

  9. The impact of introducing intensity modulated radiotherapy into routine clinical practice

    International Nuclear Information System (INIS)

    Miles, Elizabeth A.; Clark, Catharine H.; Urbano, M. Teresa Guerrero; Bidmead, Margaret; Dearnaley, David P.; Harrington, Kevin J.; A'Hern, Roger; Nutting, Christopher M.

    2005-01-01

    Background and purpose: Intensity modulated radiotherapy (IMRT) at Royal Marsden Hospital London was introduced in July 2001. Treatment delivery was dynamic using a single-phase technique. Concerns were raised regarding increased clinical workload due to introduction of new technology. The potential increased use of resources was assessed. Patients and methods: IMRT patient selection was within guidelines of clinical trials and included patients undergoing prostate plus pelvic lymph node (PPN) irradiation and head and neck cancer (HNC) treatment. Patient planning, quality assurance and treatment times were collected for an initial IMRT patient group. A comparative group of patients with advanced HNC undergoing two- or three-phase conventional radiotherapy, requiring matched photon and electron fields, were also timed. Results: The median overall total planning time for IMRT was greater for HNC patients compared to the PPN cohort. For HNC the overall IMRT planning time was significantly longer than for conventional. The median treatment time for conventional two- or three-phase HNC treatments, encompassing similar volumes to those treated with IMRT, was greater than that for the IMRT HNC patient cohort. A reduction in radiographer man hours per patient of 4.8 h was recorded whereas physics time was increased by 4.9 h per patient. Conclusions: IMRT currently increases overall planning time. Additional clinician input is required for target volume localisation. Physics time is increased, a significant component of this being patient specific QA. Radiographer time is decreased. For HNC a single phase IMRT treatment has proven to be more efficient than a multiple phase conventional treatment. IMRT has been integrated smoothly and efficiently into the existing treatment working day. This preliminary study suggests that IMRT could be a routine treatment with efficient use of current radiotherapy resources

  10. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.

    Science.gov (United States)

    Enko, Dietmar; Fridrich, Leo; Rezanka, Erwin; Stolba, Robert; Ernst, Juliane; Wendler, Iris; Fabian, Daniel; Hauptlorenz, Susanne; Halwachs-Baumann, Gabriele

    2014-01-01

    Background: Over the last decade, clinical interest to evaluate human 25-hydroxy-vitamin D (25[OH]D) serum levels has increased exponentially. In the present study, four chemiluminescence immunoassays (CLIA), one radioimmunoassy (RIA), and one high performance liquid chromatography (HPLC) method were compared and also with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in view of 25(OH)D serum level determination. Methods: For the method comparison, blood samples from 133 consecutive patients were prospectively collected. All participants gave written informed consent for their blood samples to be used in this study. They came to the Department of Nuclear Medicine of the Central Hospital Steyr (Austria) for osteodensidometric measurement as part of their preventive medical check-up. Pearson's correlation coefficients, Bland-Altman plots, and paired t-tests were calculated. Assay-specific reference ranges were considered using blood samples from persons with normal parathormone, calcium, and total-protein values (n = 97). Results: The highest correlation was between the HPLC and the LC-MS/MS method (r = 0.96). The lowest correlation was between the cobas Vitamin D3 assay (Roche) and any of the evaluated assays (r = 0.46 - 0.63). Bland-Altman plots revealed a big negative mean bias in three assays (cobas Vitamin D3 assay [Roche]: -22.8; DiaSorin LIAISON [25[OH]D total CLIA [Diasorin]: -18.4; Diasorin 25[OH]D125 I RIA [Diasorin]: -23.8 [nmol/L]) and a much smaller positive mean bias in the other assays (ClinRep complete 25[OH]D2/D3 HPLC kit [Recipe]: 2.7; ADVIA Centaur Vitamin D total assay [Siemens]: 8.2; IDS total vitamin D assay [Immunodiagnostic Systems]: 12.1 [nmol/L]) compared to the LC-MS/MS method. Meanwhile, the manufacturer has withdrawn the cobas Vitamin D3 assay from the market. Conclusions: Poor antibody specificity with cross-reactivity to other vitamin D metabolites, incomplete extraction of the 25(OH)D analyte from the vitamin D

  11. Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.

    Science.gov (United States)

    Rossen, J W A; Friedrich, A W; Moran-Gilad, J

    2018-04-01

    Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  13. A clinical perspective on the 2016 WHO brain tumor classification and routine molecular diagnostics.

    Science.gov (United States)

    van den Bent, Martin J; Weller, Michael; Wen, Patrick Y; Kros, Johan M; Aldape, Ken; Chang, Susan

    2017-05-01

    The 2007 World Health Organization (WHO) classification of brain tumors did not use molecular abnormalities as diagnostic criteria. Studies have shown that genotyping allows a better prognostic classification of diffuse glioma with improved treatment selection. This has resulted in a major revision of the WHO classification, which is now for adult diffuse glioma centered around isocitrate dehydrogenase (IDH) and 1p/19q diagnostics. This revised classification is reviewed with a focus on adult brain tumors, and includes a recommendation of genes of which routine testing is clinically useful. Apart from assessment of IDH mutational status including sequencing of R132H-immunohistochemistry negative cases and testing for 1p/19q, several other markers can be considered for routine testing, including assessment of copy number alterations of chromosome 7 and 10 and of TERT promoter, BRAF, and H3F3A mutations. For "glioblastoma, IDH mutated" the term "astrocytoma grade IV" could be considered. It should be considered to treat IDH wild-type grades II and III diffuse glioma with polysomy of chromosome 7 and loss of 10q as glioblastoma. New developments must be more quickly translated into further revised diagnostic categories. Quality control and rapid integration of molecular findings into the final diagnosis and the communication of the final diagnosis to clinicians require systematic attention. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Systematic Reviews Published in Emergency Medicine Journals Do Not Routinely Search Clinical Trials Registries: A Cross-Sectional Analysis.

    Science.gov (United States)

    Keil, Lukas G; Platts-Mills, Timothy F; Jones, Christopher W

    2015-10-01

    Publication bias compromises the validity of systematic reviews. This problem can be addressed in part through searching clinical trials registries to identify unpublished studies. This study aims to determine how often systematic reviews published in emergency medicine journals include clinical trials registry searches. We identified all systematic reviews published in the 6 highest-impact emergency medicine journals between January 1 and December 31, 2013. Systematic reviews that assessed the effects of an intervention were further examined to determine whether the authors described searching a clinical trials registry and whether this search identified relevant unpublished studies. Of 191 articles identified through PubMed search, 80 were confirmed to be systematic reviews. Our sample consisted of 41 systematic reviews that assessed a specific intervention. Eight of these 41 (20%) searched a clinical trials registry. For 4 of these 8 reviews, the registry search identified at least 1 relevant unpublished study. Systematic reviews published in emergency medicine journals do not routinely include searches of clinical trials registries. By helping authors identify unpublished trial data, the addition of registry searches may improve the validity of systematic reviews. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  15. "There are too many, but never enough": qualitative case study investigating routine coding of clinical information in depression.

    Science.gov (United States)

    Cresswell, Kathrin; Morrison, Zoe; Kalra, Dipak; Sheikh, Aziz

    2012-01-01

    We sought to understand how clinical information relating to the management of depression is routinely coded in different clinical settings and the perspectives of and implications for different stakeholders with a view to understanding how these may be aligned. Qualitative investigation exploring the views of a purposefully selected range of healthcare professionals, managers, and clinical coders spanning primary and secondary care. Our dataset comprised 28 semi-structured interviews, a focus group, documents relating to clinical coding standards and participant observation of clinical coding activities. We identified a range of approaches to coding clinical information including templates and order entry systems. The challenges inherent in clearly establishing a diagnosis, identifying appropriate clinical codes and possible implications of diagnoses for patients were particularly prominent in primary care. Although a range of managerial and research benefits were identified, there were no direct benefits from coded clinical data for patients or professionals. Secondary care staff emphasized the role of clinical coders in ensuring data quality, which was at odds with the policy drive to increase real-time clinical coding. There was overall no evidence of clear-cut direct patient care benefits to inform immediate care decisions, even in primary care where data on patients with depression were more extensively coded. A number of important secondary uses were recognized by healthcare staff, but the coding of clinical data to serve these ends was often poorly aligned with clinical practice and patient-centered considerations. The current international drive to encourage clinical coding by healthcare professionals during the clinical encounter may need to be critically examined.

  16. Clinical utility of the cryptococcal antigen lateral flow assay in a diagnostic mycology laboratory.

    Directory of Open Access Journals (Sweden)

    Brendan J McMullan

    Full Text Available BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA to detect cryptococcal antigen (CRAG is reportedly more rapid and convenient than standard latex agglutination (LA, but has not yet been evaluated in a diagnostic laboratory setting. METHODS: One hundred and six serum, 42 cerebrospinal fluid (CSF, and 20 urine samples from 92 patients with known or suspected cryptococcosis were tested by LA and LFA, and titres were compared. Results were correlated with laboratory-confirmed cryptococcosis. Serial samples were tested in nine treated patients. RESULTS: Twenty-five of 92 patients had confirmed cryptococcosis; all sera (n = 56 from these patients were positive by LFA (sensitivity 100%, 95% confidence interval (CI 93.6-100% compared with 51/56 positive by LA (sensitivity 91.1%, 95% CI 80.7-96.1%. Fifty sera from 67 patients without cryptococcosis tested negative in both assays. While LA yielded more false negative results (5/56 this did not reach statistical significance (p = 0.063. Nine CSF samples from patients with cryptococcal meningitis yielded positive results using both assays while 17/18 urine samples from patients with cryptococcosis were positive by the LFA. The LFA detected CRAG in C. gattii infection (n = 4 patients. Agreement between titres obtained by both methods (n = 38 samples was imperfect; correlation between log-transformed titres (r was 0.84. Turn-around-time was 20 minutes for the LFA and 2 h for LA. The cost per qualitative sample was 18USD and 91 USD, respectively and per quantitative sample was 38USD and 144USD, respectively. CONCLUSIONS: Qualitative agreement between the LFA and LA assays performed on serum and CSF was good but agreement between titres was imperfect. Ease of performance of the LFA and the capacity for testing urine suggest it has a role in the routine laboratory as a rapid diagnostic test or point-of-care test.

  17. Comparison of cell-based and non-cell-based assay platforms for the detection of clinically relevant anti-drug neutralizing antibodies for immunogenicity assessment of therapeutic proteins.

    Science.gov (United States)

    Hu, Jenny; Wala, Iwona; Han, Hong; Nagatani, Janice; Barger, Troy; Civoli, Francesca; Kaliyaperumal, Arunan; Zhuang, Yao; Gupta, Shalini

    2015-04-01

    Anti-drug neutralizing antibodies (NAbs) formed due to unwanted immunogenicity of a therapeutic protein point towards a mature immune response. NAb detection is important in interpreting the therapeutic's efficacy and safety in vivo. In vitro cell-based NAb assays provide a physiological system for NAb detection, however are complex assays. Non-cell-based competitive ligand binding (CLB) approaches are also employed for NAb detection. Instead of cells, CLB assays use soluble receptor and conjugated reagents and are easier to perform, however have reduced physiological relevance. The aim of this study was to compare the performance of CLB assays to established cell-based assays to determine the former's ability to detect clinically relevant NAbs towards therapeutics that (i) acted as an agonist or (ii) acted as antagonists by binding to a target receptor. We performed a head-to-head comparison of the performance of cell-based and CLB NAb assays for erythropoietin (EPO) and two anti-receptor monoclonal antibodies (AMG-X and AMG 317). Clinically relevant NAb-positive samples identified previously by a cell-based assay were assessed in the corresponding CLB format(s). A panel of 12 engineered fully human anti-EPO monoclonal antibodies (MAbs) was tested in both EPO NAb assay formats. Our results showed that the CLB format was (i) capable of detecting human anti-EPO MAbs of differing neutralizing capabilities and affinities and (ii) provided similar results as the cell-based assay for detecting NAbs in patient samples. The cell-based and CLB assays also behaved comparably in detecting NAbs in clinical samples for AMG-X. In the case of anti-AMG 317 NAbs, the CLB format failed to detect NAbs in more than 50% of the tested samples. We conclude that assay sensitivity, drug tolerance and the selected assay matrix played an important role in the inability of AMG 317 CLB assays to detect clinically relevant NAbs. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Quantitative assessment of radiation-induced lung changes by computerized optical densitometry of routine chest x-rays

    International Nuclear Information System (INIS)

    Bentzen, Soeren M.; Skoczylas, Jerzy Z.; Overgaard, Marie; Overgaard, Jens; Nielsen, Ole G.; Madsen, Erik Hjoellund

    1996-01-01

    Purpose: To develop a quantitative assay of radiological lung changes after postmastectomy radiotherapy applicable for analysis of routine chest x-rays. Methods and Materials: The assay relies on measurement of the optical density of chest x-rays by means of a standard personal computer-controlled film densitometer used for scanning dosimetry films. Density profiles were recorded at 1 mm steps along two reference lines in each lung. The crossing between the clavicula and the first rib in the x-ray projection was used as an easily identifiable anatomical landmark and was used to establish two parallel cranio-caudal reference lines separated by 20 mm. The starting point for recording optical densities was 5 mm below a line perpendicular to the reference lines and tangent to the top of the lung. Data were stored in a computer file for subsequent processing. The optical film densities in the apex of the lungs were converted into equivalent absorber thickness (EAT). To minimize the dependency on technical factors, the unirradiated lung was used as a control. Lung density changes were quantified by the relative change in EAT (REAT), which was evaluated as the difference between the summed EATs along the reference lines in the two lungs, corrected for any pretreatment difference in lung density, and taken as a percentage of the pretreatment EAT value of the lung. Results: Four different tests were carried out to investigate the reproducibility and validity of the proposed assay. (a) An anthropomorphic phantom was used to test the relationship between REAT and the layer of plastic absorber placed in front of one lung. A linear relationship was found with a correlation coefficient of 0.9993. (b) A series of 10 repeat measurements of the same arbitrarily chosen x-ray showed a mean REAT value of 9.8%, with a standard deviation of 0.21%. (c) Forty-three chest x-rays exposed on the same day were available from the clinical series. These were treated as double determinations of

  19. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  20. Absence of Decline of Kidney Function in Human Immunodeficiency Virus-Infected Patients Under Routine Clinical Management.

    Science.gov (United States)

    Boucquemont, Julie; Lawson-Ayayi, Sylvie; Rigothier, Claire; Bonnet, Fabrice; Proust-Lima, Cécile; Neau, Didier; Greib, Carine; Miremont-Salamé, Ghada; Dabis, François; Dupon, Michel; Dauchy, Frédéric-Antoine

    2017-01-01

    Since the introduction of antiretroviral therapy (ART), human immunodeficiency virus (HIV)-infected patients have a drastically improved prognosis but at the same time they are also more affected by non-HIV related complications, such as chronic kidney disease. The objective of our study was to investigate the effect of proteinuria and tenofovir (TDF)-containing ART regimens on the temporal evolution of estimated glomerular filtration rate (eGFR). Between April 2008 and October 2012, we enrolled 395 patients with a complete renal evaluation among patients from the ANRS C03 Aquitaine cohort, a prospective hospital-based cohort of HIV-1-infected patients under routine clinical management in southwestern France. eGFR was estimated at each patient follow-up visit. A linear mixed model was used to analyze eGFR dynamics, accounting for change in TDF by modeling eGFR trajectory according to treatment periods. At inclusion, 56.7% of patients were treated with TDF-containing ART regimens; prevalence of glomerular and tubular proteinuria was 7.9 and 10.8% respectively. A 1-year increase of cumulative exposure to TDF was significantly associated with a mean eGFR decrease of 1.27 mL/min/1.73 m2 (95% CI [-2.14 to -0.41]). Only a urine protein to creatinine ratio >100 mg/mmol and/or a urine albumin to creatinine ratio >70 mg/mmol were associated with eGFR trajectory (mean slope 6.18 mL/min/1.73 m2 per year; 95% CI [2.71 to 9.65]), whereas TDF use was not associated with such eGFR temporal evolution. Decline in kidney function is limited under routine clinical management with monitoring of renal function and interventions including decision to continue or discontinue TDF. © 2017 S. Karger AG, Basel.

  1. Comparison of multiplex RT-PCR and real-time HybProbe assay for serotyping of dengue virus using reference strains and clinical samples from India

    Directory of Open Access Journals (Sweden)

    Anita Chakravarti

    2016-01-01

    Full Text Available Background: Dengue virus serotyping is crucial from clinical management and epidemiological point of view. Aims: To compare efficacy of two molecular detection and typing methods, namely, multiplex reverse transcription polymerase chain reaction (RT-PCR and real-time Hybprobe assay using a panel of known dilution of four reference Dengue virus strains and a panel of sera collected from clinically suspected dengue patients. Settings: This study was conducted at a tertiary-care teaching hospital in Delhi, India. Materials and Methods: Dengue serotype specific virus strains were used as prototypes for serotyping assays. Viral load was quantified by quantitative real time reverse transcription polymerase chain reaction (qRT-PCR. Acute phase serum samples were collected from 79 patients with clinically suspected Dengue fever on their first day of presentation during September-October 2012. Viral RNA from serum and cell culture supernatant was extracted. Reverse transcription was carried out. Quantitative detection of DENV RNA from reference strain culture supernatants and each of the 79 patient samples by real-time PCR was performed using light cycler Taqman master mix kit. Serotyping was done by multiplex RT-PCR assay and Hybprobe assay. Results: The multiplex RT-PCR assay, though found to be 100% specific, couldn't serotype either patient or reference strains with viral load less than 1000 RNA copies/ml. The Hybprobe assay was found to have 100% specificity and had a lower limit of serotype detection of merely 3.54 RNA copies/ml. Conclusions: HybProbe assay has an important role especially in situations where serotyping is to be performed in clinical samples with low viral load.

  2. Feasibility of the fluorometric microculture cytotoxicity assay (FMCA) for cytotoxic drug sensitivity testing of tumor cells from patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Nygren, P; Kristensen, J; Jonsson, B; Sundström, C; Lönnerholm, G; Kreuger, A; Larsson, R

    1992-11-01

    The automated fluorometric microculture cytotoxicity assay (FMCA) was used for chemotherapeutic drug sensitivity testing of fresh and cryopreserved tumor cells from patients with acute lymphoblastic leukemia (ALL) at diagnosis and relapse. The technique success rate was 87% for fresh and 81% for cryopreserved samples. Up to 16 different cytotoxic drugs were routinely tested, but neither asparaginase nor methotrexate produced dose-response related cell kill. FMCA data showed good correlation to the well established Disc assay and the drug sensitivity reported by the FMCA was in good agreement with known clinical activity. Samples from children and initial ALL tended to be more drug sensitive than those from adults and ALL at relapse, respectively. For 36 samples clinical outcome was correlated to the quartile position in comparison to all other samples for the most in vitro active drug actually given to the patient. For patients with samples in the first, second, third, and fourth quartiles, the probabilities of complete remission were 89, 57, 38, and 0%, respectively. Using the median value as cut-off line, the sensitivity and specificity of the assay were 87 and 62%, respectively. It is concluded that the FMCA with a minimum of effort and with high success rate report clinically relevant drug sensitivity profiles for ALL.

  3. Clinical significance of serum thymosin α1 assay in tumor patients

    International Nuclear Information System (INIS)

    Wang Jiamin; Lv Ming'en; Zhao Xiaojuan; Gao Weiqiang; Bai Xia; Wang Zhaoyue

    2003-01-01

    Objective: To investigate the clinical significance of thymosin α1(Tα1) measurement in evaluating clinical status of patients with solid malignant tumors. Methods: Tα1 levels in serum of 50 normal adults, 20 patients with benign tumors and 63 patients with malignant tumors were measured by enzyme linked immunosorbent assay (ELISA). The association of Tα1 level with tumor invasion, metastasis and its alteration after different treatment in patients with malignant tumors were also studied. Results: The serum Tα1 level was 0.69±0.35 μg/L in normal adults, 0.96±0.37 μg/L in patients with benign tumors and 1.46±0.90 μg/L in patients with malignant tumors. In comparison it was both increased between patients with benign and malignant tumors and the normal adults (P<0.01 and P<0.001). And its increasing extent in malignant tumors was much greater than that in benign tumors (P<0.05). The serum Tα1 level in patients with malignant tumors was correlated with tumor invasion, metastasis and different treatment intervention. Conclusions: Our findings suggest that the serum Tα1 level be increased in tumor patients, and that it may be used as a new tumor marker in clinic

  4. Computerized low-level waste assay system operation manual

    International Nuclear Information System (INIS)

    Jones, D.F.; Cowder, L.R.; Martin, E.R.

    1976-01-01

    An operation and maintenance manual for the computerized low-level waste box counter is presented, which describes routine assay techniques as well as theory of operation treated in sufficient depth so that an experienced assayist can make nonroutine assays. In addition, complete system schematics are included, along with a complete circuit description to facilitate not only maintenance and troubleshooting, but also reproduction of the instrument if desired. Complete software system descriptions are included so far as calculational algorithms are concerned, although detailed instruction listings would have to be obtained from Group R-1 at LASL in order to make machine-language code changes

  5. [Quantitative fluorogenic real-time PCR assay for respiratory syncytial virus detection].

    Science.gov (United States)

    Zhang, Qi-wei; You, Shang-you; Sun, Ji-min; Wu, Qi; Yu, Chun-hua; Zhang, Chu-yu

    2005-07-01

    To Establish a rapid and objective quantitative fluorogenic real-time PCR assay for early detection of human respiratory syncytial virus (hRSV). Two pairs of primers and one TaqMan Fluorogenic probe that are specific for the recognition of the most conservative N gene of hRSV for virus detection with LighCycler PCR in 93 nasopharyngeal secretion specimens collected from infants and young children. The assay was compared with virus isolation, routine PCR, nested PCR, and enzyme-linked immunosorbent assay (ELISA). This TaqMan assay had a sensitivity of 1 x 10(2) cDNA copies/microl with a dynamic range between 1 x 10(2) and 1 x 10(7) cDNA copies/microl, which was the same as that of nested PCR, but 10 times more sensitive than routine PCR. The specificity of the assay was evaluated by comparing hRSV with polivirus type 1, coxsackie virus type 2, influenza A, influenza B and adenovirus type 7. A PCR product of the expected size (195 bp) was produced and fluorescence signal detected for hRSV, but not for any of the other viruses. The results in LightCycler and Rotor-Gene instrument were consistent. Forty-four specimens (43.9%) were hRSV-positive with this assay and 4 (4/93,4.3%) were hRSV-positive with ELISA, showing rather low correlation between the two methods. No visible relation was found between the concentration of hRSV RNA and severity of the disease. This assay is rapid, sensitive, specific and quantitative, and has the potential of wide application for early diagnosis of hRSV infection and evaluation of the therapeutic effect.

  6. Comparison of mRNA splicing assay protocols across multiple laboratories: recommendations for best practice in standardized clinical testing.

    Science.gov (United States)

    Whiley, Phillip J; de la Hoya, Miguel; Thomassen, Mads; Becker, Alexandra; Brandão, Rita; Pedersen, Inge Sokilde; Montagna, Marco; Menéndez, Mireia; Quiles, Francisco; Gutiérrez-Enríquez, Sara; De Leeneer, Kim; Tenés, Anna; Montalban, Gemma; Tserpelis, Demis; Yoshimatsu, Toshio; Tirapo, Carole; Raponi, Michela; Caldes, Trinidad; Blanco, Ana; Santamariña, Marta; Guidugli, Lucia; de Garibay, Gorka Ruiz; Wong, Ming; Tancredi, Mariella; Fachal, Laura; Ding, Yuan Chun; Kruse, Torben; Lattimore, Vanessa; Kwong, Ava; Chan, Tsun Leung; Colombo, Mara; De Vecchi, Giovanni; Caligo, Maria; Baralle, Diana; Lázaro, Conxi; Couch, Fergus; Radice, Paolo; Southey, Melissa C; Neuhausen, Susan; Houdayer, Claude; Fackenthal, Jim; Hansen, Thomas Van Overeem; Vega, Ana; Diez, Orland; Blok, Rien; Claes, Kathleen; Wappenschmidt, Barbara; Walker, Logan; Spurdle, Amanda B; Brown, Melissa A

    2014-02-01

    Accurate evaluation of unclassified sequence variants in cancer predisposition genes is essential for clinical management and depends on a multifactorial analysis of clinical, genetic, pathologic, and bioinformatic variables and assays of transcript length and abundance. The integrity of assay data in turn relies on appropriate assay design, interpretation, and reporting. We conducted a multicenter investigation to compare mRNA splicing assay protocols used by members of the ENIGMA (Evidence-Based Network for the Interpretation of Germline Mutant Alleles) consortium. We compared similarities and differences in results derived from analysis of a panel of breast cancer 1, early onset (BRCA1) and breast cancer 2, early onset (BRCA2) gene variants known to alter splicing (BRCA1: c.135-1G>T, c.591C>T, c.594-2A>C, c.671-2A>G, and c.5467+5G>C and BRCA2: c.426-12_8delGTTTT, c.7988A>T, c.8632+1G>A, and c.9501+3A>T). Differences in protocols were then assessed to determine which elements were critical in reliable assay design. PCR primer design strategies, PCR conditions, and product detection methods, combined with a prior knowledge of expected alternative transcripts, were the key factors for accurate splicing assay results. For example, because of the position of primers and PCR extension times, several isoforms associated with BRCA1, c.594-2A>C and c.671-2A>G, were not detected by many sites. Variation was most evident for the detection of low-abundance transcripts (e.g., BRCA2 c.8632+1G>A Δ19,20 and BRCA1 c.135-1G>T Δ5q and Δ3). Detection of low-abundance transcripts was sometimes addressed by using more analytically sensitive detection methods (e.g., BRCA2 c.426-12_8delGTTTT ins18bp). We provide recommendations for best practice and raise key issues to consider when designing mRNA assays for evaluation of unclassified sequence variants.

  7. Evaluation and validation of a real-time PCR assay for detection and quantitation of human adenovirus 14 from clinical samples.

    Directory of Open Access Journals (Sweden)

    David Metzgar

    Full Text Available In 2007, the Centers for Disease Control and Prevention (CDC reported that Human adenovirus type 14 (HAdV-14 infected 106 military personnel and was responsible for the death of one U.S. soldier at Lackland Air Force Base in Texas. Identification of the responsible adenovirus, which had not previously been seen in North America and for which rapid diagnostic tools were unavailable, required retrospective analysis at reference laboratories. Initial quarantine measures were also reliant on relatively slow traditional PCR analysis at other locations. To address this problem, we developed a real-time PCR assay that detects a 225 base pair sequence in the HAdV-14a hexon gene. Fifty-one oropharyngeal swab specimens from the Naval Health Research Center, San Diego, CA and Advanced Diagnostic Laboratory, Lackland AFB, TX were used to validate the new assay. The described assay detected eight of eight and 19 of 19 confirmed HAdV-14a clinical isolates in two separate cohorts from respiratory disease outbreaks. The real-time PCR assay had a wide dynamic range, detecting from 10(2 to 10(7 copies of genomic DNA per reaction. The assay did not cross-react with other adenoviruses, influenza, respiratory syncytial virus, or common respiratory tract bacteria. The described assay is easy to use, sensitive and specific for HAdV-14a in clinical throat swab specimens, and very rapid since turnaround time is less than four hours to obtain an answer.

  8. NON-ADHERENCE IN SENIORS WITH DEMENTIA – A SERIOUS PROBLEM OF ROUTINE CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    Jan Lužný

    2014-01-01

    Full Text Available Background: Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. Aim: to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Subjects and Methods: Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Results: Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. Conclusion: In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment – a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  9. Routine hemoglobin electrophoresis for pediatric surgery day case ...

    African Journals Online (AJOL)

    2015-09-25

    Sep 25, 2015 ... 2016 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer - Medknow ... surgery day case in at-risk populations: Suggested algorithm for screening .... HBE is a routine preoperative investigation before a surgical ...

  10. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein.

    Science.gov (United States)

    Rasmussen, M; Dahl, M; Buus, S; Djurisic, S; Ohlsson, J; Hviid, T V F

    2014-08-01

    The human leukocyte antigen (HLA) class Ib molecule, HLA-G, has gained increased attention because of its assumed important role in immune regulation. The HLA-G protein exists in several soluble isoforms. Most important are the actively secreted HLA-G5 full-length isoform generated by alternative splicing retaining intron 4 with a premature stop codon, and the cleavage of full-length membrane-bound HLA-G1 from the cell surface, so-called soluble HLA-G1 (sHLA-G1). A specific and sensitive immunoassay for measurements of soluble HLA-G is mandatory for conceivable routine testing and research projects. We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed that the sHLA-G immunoassay was highly specific. Optimal combinations of competitor sHLA-G1 and capture mAb concentrations were determined. Two versions of the assay were tested. One with a relatively wide dynamic range from 3.1 to 100.0 ng/ml, and another more sensitive version ranging from 1.6 to 12.5 ng/ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer, and certain pregnancy complications, both in research studies and possibly in the future also for clinical routine use. © 2014 John Wiley & Sons A/S. Published by John Wiley

  11. Clinical value of determination of TSH-binding inhibiting immunoglobulins (TBII) by a radioreceptor assay

    International Nuclear Information System (INIS)

    Heberling, H.J.; Bierwolf, B.; Lohmann, D.

    1986-01-01

    The clinical value of a commercial kit for determination of TBII was evaluated. 50 patients with untreated Graves' disease, 21 patients with Graves' disease before and during medical therapy, 18 patients after finishing medical therapy and 10 patients after surgical treatment were examined. Besides these, 41 patients with other thyroid diseases and 36 patients without any thyroid disorder were included. In 47 (94%) of 50 patients with untreated Graves' disease TBII were detectable in serum using a TSH standard curve. Binding activities exceeding 10 U/l TSH equivalents were regarded as positive. In other thyroid diseases TBII were negative with the exception of 3 of 22 patient with autonomously functioning thyroid nodules. After 12 months of antithyroid drug treatment of 19 patients the incidence of positive antibody findings was 26%. During follow-up after medical therapy (1-9 years) 7 of 18 patients had increased TBII in correlation with clinical and functional findings. The determination of TBII by TRAK assay proved to be a sensitive and specific method. The assay can be used to differentiate between hyperthyroidism of autoimmune or non-immunogenic origin. Thus the method seems to be helpful for the follow-up under medical treatment of patients with Graves' disease. (author)

  12. Post-use assay of vaginal rings (VRs) as a potential measure of clinical trial adherence.

    Science.gov (United States)

    Spence, Patrick; Nel, Annalene; van Niekerk, Neliëtte; Derrick, Tiffany; Wilder, Susan; Devlin, Bríd

    2016-06-05

    Adherence measurement for microbicide use within the clinical trial setting remains a challenge for the HIV prevention field. This paper describes an assay method used for determining residual dapivirine levels in post-use vaginal rings from clinical trials conducted with the Dapivirine Vaginal Matrix Ring-004 developed by the International Partnership for Microbicides to prevent male to female HIV transmission. Post-use assay results from three Ring-004 clinical trials showed that of the 25mg drug load, approximately 4mg of dapivirine is released from the matrix ring over a 28-day use period. Data obtained by both in vitro and in vivo studies indicate that dapivirine is released according to a diffusion mechanism, as determined by conformance of both data sets to the Higuchi equation. This, coupled with the low variability associated with batch production over two manufacturing sites and 20 batches of material, provides evidence that post-use ring analysis can contribute to the assessment of adherence to ring use. Limitations of this method include the potential of intra-participant and inter-participant variability and uncertainty associated with measuring the low amount of dapivirine actually released relative to the drug load. Therefore, residual drug levels should not serve as the only direct measurement for microbicide adherence in vaginal ring clinical trials but should preferably be used as part of a multi-pronged approach towards understanding and assessing adherence to vaginal ring use. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Pathology consultation on anticoagulation monitoring: factor X-related assays.

    Science.gov (United States)

    Wool, Geoffrey D; Lu, Chuanyi M

    2013-11-01

    To review various anticoagulation therapies and related laboratory monitoring issues, with a focus on factor X-related chromogenic assays. A case-based approach is used to review pertinent published literatures and product inserts of anticoagulation drugs and to look back on clinical use of factor X-related chromogenic assays. The number of anticoagulants available to clinicians has increased greatly in the past decade. Whether and how these anticoagulants should be monitored are areas of uncertainty for clinicians, which can lead to misuse of laboratory assays and suboptimal patient management. Factor X-related assays are of particular concern because of the similar and often confusing test names. Based on a common clinical case scenario and literature review regarding anticoagulant monitoring, an up-to-date discussion and review of the various factor X-related assays are provided, focusing on the differences in test designs and clinical utilities between the chromogenic anti-Xa and chromogenic factor X activity assays. Anticoagulation therapy and related laboratory monitoring are rapidly evolving areas of clinical practices. A good knowledge of relevant laboratory assays and their clinical applications is necessary to help optimize patient care.

  14. Hb variants in Korea: effect on HbA1c using five routine methods.

    Science.gov (United States)

    Yun, Yeo-Min; Ji, Misuk; Ko, Dae-Hyun; Chun, Sail; Kwon, Gye Cheol; Lee, Kyunghoon; Song, Sang Hoon; Seong, Moon Woo; Park, Sung Sup; Song, Junghan

    2017-07-26

    Quantification of glycated hemoglobin (HbA1c) is a challenge in patients with hemoglobin (Hb) variants. We evaluated the impact of various Hb variants on five routine HbA1c assays by comparing with the IFCC reference measurement procedure (RMP). Whole blood samples showing warning flags or no results on routine HPLC HbA1c assays were confirmed for Hb variants and were submitted to HbA1c quantification using Sebia Capillarys 2 Flex Piercing, Roche Tina-quant HbA1c Gen. 2, Bio-Rad Variant II Turbo 2.0, ADAMS HA-8180, Tosoh G8 standard mode, and IFCC RMP using LC-MS. Among 114 samples, the most common variants were Hb G-Coushatta (n=47), Queens (n=41), Ube-4 (n=11), Chad (n=4), Yamagata (n=4), G-His-Tsou (n=2), G-Taipei (n=1), Fort de France (n=1), Hoshida (n=1), and two novel variants (Hb α-globin, HBA 52 Gly>Cys and Hb β-globin, HBB 146 His>Asn). In terms of control samples, all the result of HbA1c were "acceptable", within the criteria of ±7% compared to IFCC RMP target values. However, percentage of "unacceptable" results of samples with Hb variants were 16% for Capillarys 2, 7% for Tina-quant, 51% for Variant II Turbo 2.0, 95% for G8 standard mode, and 89% for HA-8180. The Capillarys 2 and HA-8180 assay did not provide the results in 5 and 40 samples with Hb variants, respectively. HbA1c results from five routine assays in patients with relatively common Hb variants in Korea showed various degrees of bias compared to those of IFCC RMP. Therefore, laboratories should be aware of the limitation of their methods with respect to interference from Hb variants found commonly in their local population and suggest an alternative HbA1c quantification method.

  15. Prospective and retrospective evaluation of the Cepheid Xpert® Flu/RSV XC assay for rapid detection of influenza A, influenza B, and respiratory syncytial virus.

    Science.gov (United States)

    Salez, Nicolas; Nougairede, Antoine; Ninove, Laetitia; Zandotti, Christine; de Lamballerie, Xavier; Charrel, Remi N

    2015-04-01

    A total of 281 clinical specimens (nasal swabs and nasopharyngeal aspirates) were tested with the Xpert® Flu/RSV XC. The results were compared to those obtained with the real-time retro transcriptase-polymerase chain reaction assays routinely used in our laboratory. The Xpert® Flu/RSV XC showed sensitivity/specificity of 97.8%/100% and 97.9%/100% for flu and respiratory syncytial virus, respectively. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    Science.gov (United States)

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  17. Loop-mediated isothermal amplification assay for rapid and sensitive detection of sheep pox and goat pox viruses in clinical samples.

    Science.gov (United States)

    Venkatesan, G; Balamurugan, V; Bhanuprakash, V; Singh, R K; Pandey, A B

    2016-06-01

    A Loop-mediated isothermal amplification (LAMP) assay targeting the highly conserved DNA polymerase gene of capripox virus genome was developed and evaluated for rapid detection of sheep pox and goat pox viruses. The optimized LAMP assay is found specific and sensitive for amplification of target DNA with a diagnostic sensitivity and specificity of 96.6% and 100% respectively compared to quantitative PCR. The detection rate of LAMP, PCR and Q-PCR assays is found to be 81.5%, 67% and 83% respectively. This LAMP assay has the potential for rapid clinical diagnosis and surveillance of sheep pox and goat pox in field diagnostic laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Patients' perceptions of sharing in decisions: a systematic review of interventions to enhance shared decision making in routine clinical practice.

    Science.gov (United States)

    Légaré, France; Turcotte, Stéphane; Stacey, Dawn; Ratté, Stéphane; Kryworuchko, Jennifer; Graham, Ian D

    2012-01-01

    Shared decision making is the process in which a healthcare choice is made jointly by the health professional and the patient. Little is known about what patients view as effective or ineffective strategies to implement shared decision making in routine clinical practice. This systematic review evaluates the effectiveness of interventions to improve health professionals' adoption of shared decision making in routine clinical practice, as seen by patients. We searched electronic databases (PubMed, the Cochrane Library, EMBASE, CINAHL, and PsycINFO) from their inception to mid-March 2009. We found additional material by reviewing the reference lists of the studies found in the databases; systematic reviews of studies on shared decision making; the proceedings of various editions of the International Shared Decision Making Conference; and the transcripts of the Society for Medical Decision Making's meetings. In our study selection, we included randomized controlled trials, controlled clinical trials, controlled before-and-after studies, and interrupted time series analyses in which patients evaluated interventions to improve health professionals' adoption of shared decision making. The interventions in question consisted of the distribution of printed educational material; educational meetings; audit and feedback; reminders; and patient-mediated initiatives (e.g. patient decision aids). Two reviewers independently screened the studies and extracted data. Statistical analyses considered categorical and continuous process measures. We computed the standardized effect size for each outcome at the 95% confidence interval. The primary outcome of interest was health professionals' adoption of shared decision making as reported by patients in a self-administered questionnaire. Of the 6764 search results, 21 studies reported 35 relevant comparisons. Overall, the quality of the studies ranged from 0% to 83%. Only three of the 21 studies reported a clinically significant effect

  19. ‘True’ antimitochondrial antibody-negative primary biliary cirrhosis, low sensitivity of the routine assays, or both?

    Science.gov (United States)

    MURATORI, P; MURATORI, L; GERSHWIN, M E; CZAJA, A J; PAPPAS, G; MACCARIELLO, S; GRANITO, A; CASSANI, F; LORIA, P; LENZI, M; BIANCHI, F B

    2004-01-01

    Anti-mitochondrial antibody (AMA) is considered the serological hallmark of primary biliary cirrhosis (PBC), but may be missing in a proportion of these patients. We assessed sensitivity and specificity of the currently available techniques for AMA detection in a large series of PBC patients and controls, and analysed their clinical and immunological features according to the AMA status. By indirect immunofluorescence on rat tissue sections and HEp-2 cells, Western immunoblot with bovine submitochondrial particles, and two ELISAs with AMA-specific recombinant proteins, we evaluated the presence of AMA in 127 PBC patients, 166 patients with type 1 autoimmune hepatitis and 100 with non alcoholic fatty liver disease. In PBC patients Western immunoblot detects AMA significantly more often than indirect immunofluorescence on HEp-2 cells (85% versus 72%, P = 0·02) or rodent tissue sections (71%, P = 0·01); both ELISAs are only slightly less sensitive than Western immunoblot (81% and 78%). Ten patients with non alcoholic fatty liver disease were AMA-positive by indirect immunofluorescence, but none recognized AMA-specific epitopes in Western immunoblot or in ELISAs. Twelve patients with type 1 autoimmune hepatitis were AMA-positive by indirect immunofluorescence, but only 6 (3·6%) reacted by Western immunoblot and ELISAs. Western immunoblot or ELISA should be regarded as first-line assay for the detection of AMA. Up to 15% of PBC patients are consistently AMA-negative, yet they share the same clinical, biochemical and histological features of AMA-positive PBC. Detection of AMA in type 1 autoimmune hepatitis might identify a subset of patients at risk of developing a hepatitic/cholestatic syndrome. PMID:14678277

  20. Development of a solid-phase assay for measurement of proteolytic enzyme activity

    International Nuclear Information System (INIS)

    Varani, J.; Johnson, K.; Kaplan, J.

    1980-01-01

    A solid-phase, plate assay was developed for the measurement of proteolytic enzyme activity. In this assay procedure, radiolabeled substrates were dried onto the surface of microtiter wells. Following drying, the wells were washed two times with saline to remove the nonadherent substrate. When proteolytic enzymes were added to the wells, protein hydrolysis occurred, releasing radioactivity into the supernatant fluid. The amount of protein hydrolysis that occurred was reflected by the amount of radioactivity in the supernatant fluid. When 125 I-hemoglobin was used as the substrate, it was as susceptible to hydrolysis by trypsin in the solid-phase assay as it was in solution in a standard assay procedure. Protease activity from a variety of sources (including from viable cells as well as from extracellular sources) were also able to hydrolyze the hemoglobin on the plate. 125 I-Labeled serum albumen, fibrinogen, and rat pulmonary basement membrane were also susceptible to hydrolysis by trypsin in the solid phase. When [ 14 C]elastin was dried onto the plate, it behaved in a similar manner to elastin in solution. It was resistant to hydrolysis by nonspecific proteases such as trypsin and chymotrypsin but was highly susceptible to hydrolysis by elastase. The solid-phase plate assay has several features which recommended it for routine use. It is as sensitive as standard tube assays (and much more sensitive than routinely used colormetric assays). It is quick and convenient; there are no precipitation, centrifugation, or filtration steps. In addition, very small volumes of radioactive wastes are generated. Another advantage of the solid-phase plate assay is the resistance of the dried substrates to spontaneous breakdown and to microbial contamination. Finally, this assay is suitable for use with viable cells as well as for extracellular proteases

  1. Factors Associated with Routine Dental Attendance among Aboriginal Australians.

    Science.gov (United States)

    Amarasena, Najith; Kapellas, Kostas; Skilton, Michael R; Maple-Brown, Louise J; Brown, Alex; Bartold, Mark; O'Dea, Kerin; Celermajer, David; Jamieson, Lisa M

    2016-01-01

    To determine factors associated with routine dental attendance in Aboriginal Australians. Data of 271 Aboriginal adults residing in Australia's Northern Territory were used. Routine dental attendance was defined as last visiting a dentist less than one year ago or visiting a dentist for a check-up. Both bivariate and multivariable analytical techniques were used. While 27% visited a dentist in the past year, 29% of these visited for a check-up. In bivariate analysis, being female, low psychological distress, and low clinical attachment loss (CAL) were associated with visiting a dentist within last year. Being aged younger than 39 years, male, no oral health impairment, being caries-free, low CAL, and low apolipoprotein B were associated with visiting for a check-up. Clinical attachment loss remained associated with visiting a dentist less than one year ago while being younger than 39 years and having no oral health impairment remained associated with usually visiting for a check-up in multivariable analysis. Younger age, no oral health impairment, and low CAL were associated with routine dental attendance among Indigenous Australians.

  2. Analytical evaluation of Lumipulse® BRAHMS PCT CLEIA assay and clinical performances in an unselected population as compared with central lab PCT assay.

    Science.gov (United States)

    Dupuy, Anne Marie; Né, Maxence; Bargnoux, Anne Sophie; Badiou, Stéphanie; Cristol, Jean Paul

    2017-03-01

    We report the analytical performances of the Lumipulse®G BRAHMS PCT assay (Fujirebio, Courteboeuf, France) and the concordance with BRAHMS PCT Kryptor CompactPlus© results from central laboratory. Lumipulse®G BRAHMS PCT immunoassay on Lumipulse®G600II instrument is a chemiluminescence enzyme immunoassay (CLEIA). Analytical performances included imprecision study, linearity, limit of detection and comparison study on 138 plasma specimen on Lumipulse®G600II vs plasma on Kryptor CompactPlus©. The intra and inter assay imprecision of Lumipulse®G BRAHMS PCT was between 2 and 5%. The LoD in our condition was 0.0029ng/mL in accordance with the LoD provided by the manufacturer (0.0048ng/mL). The linear equation of linearity was y=1,001×-0,052 with r 2 =0.99, with a mean recovery (SD) percentage of 1.8% (8%). Correlation studies showed a good correlation (r=0.99) between plasma on Kryptor and Lumipulse, with a bias of 0.02 in the range from 0.12 to 1ng/mL. The new adaptation developed from Fujirebio on quantification of PCT with CLEIA technology from monoclonal antibodies from ThermoFisher appears to be acceptable for clinical use. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Acceptability of routine offer of HIV testing (opt-out approach) among ...

    African Journals Online (AJOL)

    Background: With the introduction of the opt out HIV testing policy in Ghana, the HIV test is offered routinely to all pregnant women unless they decline testing. Objective: To assess acceptability of the routine offer of HIV testing antenatal clinic (ANC) clients in the Wa municipality, Ghana. Design: Cross-sectional study of 270 ...

  4. A Real-Time PCR Assay to Identify and Discriminate Among Wild-Type and Vaccine Strains of Varicella-Zoster Virus and Herpes Simplex Virus in Clinical Specimens, and Comparison With the Clinical Diagnoses

    Science.gov (United States)

    Harbecke, Ruth; Oxman, Michael N.; Arnold, Beth A.; Ip, Charlotte; Johnson, Gary R.; Levin, Myron J.; Gelb, Lawrence D.; Schmader, Kenneth E.; Straus, Stephen E.; Wang, Hui; Wright, Peter F.; Pachucki, Constance T.; Gershon, Anne A.; Arbeit, Robert D.; Davis, Larry E.; Simberkoff, Michael S.; Weinberg, Adriana; Williams, Heather M.; Cheney, Carol; Petrukhin, Luba; Abraham, Katalin G.; Shaw, Alan; Manoff, Susan; Antonello, Joseph M.; Green, Tina; Wang, Yue; Tan, Charles; Keller, Paul M.

    2014-01-01

    A real-time PCR assay was developed to identify varicella-zoster virus (VZV) and herpes simplex virus (HSV) DNA in clinical specimens from subjects with suspected herpes zoster (HZ; shingles). Three sets of primers and probes were used in separate PCR reactions to detect and discriminate among wild-type VZV (VZV-WT), Oka vaccine strain VZV (VZV-Oka), and HSV DNA, and the reaction for each virus DNA was multiplexed with primers and probe specific for the human β-globin gene to assess specimen adequacy. Discrimination of all VZV-WT strains, including Japanese isolates and the Oka parent strain, from VZV-Oka was based upon a single nucleotide polymorphism at position 106262 in ORF 62, resulting in preferential amplification by the homologous primer pair. The assay was highly sensitive and specific for the target virus DNA, and no cross-reactions were detected with any other infectious agent. With the PCR assay as the gold standard, the sensitivity of virus culture was 53% for VZV and 77% for HSV. There was 92% agreement between the clinical diagnosis of HZ by the Clinical Evaluation Committee and the PCR assay results. PMID:19475609

  5. Short communication prevalence of susceptibility to etravirine by genotype and phenotype in samples received for routine HIV type 1 resistance testing in the United States.

    Science.gov (United States)

    Picchio, Gaston; Vingerhoets, Johan; Tambuyzer, Lotke; Coakley, Eoin; Haddad, Mojgan; Witek, James

    2011-12-01

    Abstract The prevalence of susceptibility to etravirine was investigated among clinical samples submitted for routine clinical testing in the United States using two separate weighted genotypic scoring systems. The presence of etravirine mutations and susceptibility to etravirine by phenotype of clinical samples from HIV-1-infected patients, submitted to Monogram Biosciences for routine resistance testing between June 2008 and June 2009, were analyzed. Susceptibility by genotype was determined using the Monogram and Tibotec etravirine-weighted genotypic scoring systems, with scores of ≤3 and ≤2, respectively, indicating full susceptibility. Susceptibility by phenotype was determined using the PhenoSense HIV assay, with lower and higher clinical cut-offs of 2.9 and 10, respectively. The frequency of individual etravirine mutations and the impact of the K103N mutation on susceptibility to etravirine by genotype were also determined. Among the 5482 samples with ≥1 defined nonnucleoside reverse transcriptase inhibitor (NNRTI) mutations associated with resistance, 67% were classed as susceptible to etravirine by genotype by both scoring systems. Susceptibility to etravirine by phenotype was higher (76%). The proportion of first-generation NNRTI-resistant samples with (n=3598) and without (n=1884) K103N with susceptibility to etravirine by genotype was 77% and 49%, respectively. Among samples susceptible to first-generation NNRTIs (n=9458), >99% of samples were susceptible to etravirine by phenotype (FC <2.9); the remaining samples had FC ≥2.9-10. In summary, among samples submitted for routine clinical testing in the United States, a high proportion of samples with first-generation NNRTI resistance was susceptible to etravirine by genotype and phenotype. A higher proportion of NNRTI-resistant samples with K103N than without was susceptible to etravirine.

  6. Verification and quality control of routine hematology analyzers

    NARCIS (Netherlands)

    Vis, J Y; Huisman, A

    2016-01-01

    Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and

  7. Clinical experience with a radioreceptor assay for TSH-binding inhibiting immunoglobulins (TBII)

    International Nuclear Information System (INIS)

    Heberling, H.J.; Bierwolf, B.; Lohmann, D.

    1988-01-01

    The aim was evaluate the clinical value of a commercial kit for determination of TSH-binding inhibiting immunoglobulin (TBII). 47 of 50 patients with untreated hyperthyroid Graves' disease were TBII positive (sensitivity 94%). TBII was in the normal range in all normal volunteers and in patients with simple goiter, thyroid cancer and in most cases of nonimmunogenic hyperthyreoidism (19 of 22). After 12 months antithyroid drug therapy with methimazole of 21 patients the prevalence of positive TBII findings was 28%. In contrast to this, 50 percent of the patients had increased microsomal antibodies at the end of therapy. The determination of TBII by TRAK assay proved to be a sensitive, specific and practical method. The assay can be used to differentiate between hyperthyreoidism of autoimmune or nonimmunogenic origin. Even so this method seems to be helpful for the follow-up during medical treatment of patients with Graves' disease. The results indicate that persistence of increased TBII levels are markers of active Graves' disease and suggest that in this situation ablative measures should be performed. Normalization of TBII on the end of a longstanding antithyroid therapy does not exclude the possibility of relapse in the further course. (author)

  8. Antioxidant Generation during Coffee Roasting: A Comparison and Interpretation from Three Complementary Assays

    Directory of Open Access Journals (Sweden)

    Sebastian E. W. Opitz

    2014-11-01

    Full Text Available Coffee is a major source of dietary antioxidants; some are present in the green bean, whereas others are generated during roasting. However, there is no single accepted analytical method for their routine determination. This paper describes the adaption of three complementary assays (Folin-Ciocalteu (FC, ABTS and ORAC for the routine assessment of antioxidant capacity of beverages, their validation, and use for determining the antioxidant capacities of extracts from coffee beans at different stages in the roasting process. All assays showed a progressive increase in antioxidant capacity during roasting to a light roast state, consistent with the production of melanoidins having a higher antioxidant effect than the degradation of CGAs. However, the three assays gave different numbers for the total antioxidant capacity of green beans relative to gallic acid (GA, although the range of values was much smaller when chlorogenic acid (CGA was used as reference. Therefore, although all three assays indicated that there was an increase in antioxidant activity during coffee roasting, and the large differences in responses to GA and CGA illustrate their different sensitivities to different types of antioxidant molecule.

  9. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  10. SU-E-T-23: A Developing Australian Network for Datamining and Modelling Routine Radiotherapy Clinical Data and Radiomics Information for Rapid Learning and Clinical Decision Support

    Energy Technology Data Exchange (ETDEWEB)

    Thwaites, D [University of Sydney, Camperdown, Sydney (Australia); Holloway, L [Ingham Institute, Sydney, NSW (Australia); Bailey, M; Carolan, M; Miller, A [Illawarra Cancer Care Centre, Wollongong, NSW (Australia); Barakat, S; Field, M [University of Sydney, Sydney, NSW (Australia); Delaney, G; Vinod, S [Liverpool Hospital, Liverpool, NSW (Australia); Dekker, A [Maastro Clinic, Maastricht (Netherlands); Lustberg, T; Soest, J van; Walsh, S [MAASTRO Clinic, Maastricht (Netherlands)

    2015-06-15

    Purpose: Large amounts of routine radiotherapy (RT) data are available, which can potentially add clinical evidence to support better decisions. A developing collaborative Australian network, with a leading European partner, aims to validate, implement and extend European predictive models (PMs) for Australian practice and assess their impact on future patient decisions. Wider objectives include: developing multi-institutional rapid learning, using distributed learning approaches; and assessing and incorporating radiomics information into PMs. Methods: Two initial standalone pilots were conducted; one on NSCLC, the other on larynx, patient datasets in two different centres. Open-source rapid learning systems were installed, for data extraction and mining to collect relevant clinical parameters from the centres’ databases. The European DSSs were learned (“training cohort”) and validated against local data sets (“clinical cohort”). Further NSCLC studies are underway in three more centres to pilot a wider distributed learning network. Initial radiomics work is underway. Results: For the NSCLC pilot, 159/419 patient datasets were identified meeting the PM criteria, and hence eligible for inclusion in the curative clinical cohort (for the larynx pilot, 109/125). Some missing data were imputed using Bayesian methods. For both, the European PMs successfully predicted prognosis groups, but with some differences in practice reflected. For example, the PM-predicted good prognosis NSCLC group was differentiated from a combined medium/poor prognosis group (2YOS 69% vs. 27%, p<0.001). Stage was less discriminatory in identifying prognostic groups. In the good prognosis group two-year overall survival was 65% in curatively and 18% in palliatively treated patients. Conclusion: The technical infrastructure and basic European PMs support prognosis prediction for these Australian patient groups, showing promise for supporting future personalized treatment decisions

  11. SU-E-T-23: A Developing Australian Network for Datamining and Modelling Routine Radiotherapy Clinical Data and Radiomics Information for Rapid Learning and Clinical Decision Support

    International Nuclear Information System (INIS)

    Thwaites, D; Holloway, L; Bailey, M; Carolan, M; Miller, A; Barakat, S; Field, M; Delaney, G; Vinod, S; Dekker, A; Lustberg, T; Soest, J van; Walsh, S

    2015-01-01

    Purpose: Large amounts of routine radiotherapy (RT) data are available, which can potentially add clinical evidence to support better decisions. A developing collaborative Australian network, with a leading European partner, aims to validate, implement and extend European predictive models (PMs) for Australian practice and assess their impact on future patient decisions. Wider objectives include: developing multi-institutional rapid learning, using distributed learning approaches; and assessing and incorporating radiomics information into PMs. Methods: Two initial standalone pilots were conducted; one on NSCLC, the other on larynx, patient datasets in two different centres. Open-source rapid learning systems were installed, for data extraction and mining to collect relevant clinical parameters from the centres’ databases. The European DSSs were learned (“training cohort”) and validated against local data sets (“clinical cohort”). Further NSCLC studies are underway in three more centres to pilot a wider distributed learning network. Initial radiomics work is underway. Results: For the NSCLC pilot, 159/419 patient datasets were identified meeting the PM criteria, and hence eligible for inclusion in the curative clinical cohort (for the larynx pilot, 109/125). Some missing data were imputed using Bayesian methods. For both, the European PMs successfully predicted prognosis groups, but with some differences in practice reflected. For example, the PM-predicted good prognosis NSCLC group was differentiated from a combined medium/poor prognosis group (2YOS 69% vs. 27%, p<0.001). Stage was less discriminatory in identifying prognostic groups. In the good prognosis group two-year overall survival was 65% in curatively and 18% in palliatively treated patients. Conclusion: The technical infrastructure and basic European PMs support prognosis prediction for these Australian patient groups, showing promise for supporting future personalized treatment decisions

  12. Novel Risk Stratification Assays for Acute Coronary Syndrome.

    Science.gov (United States)

    Ahmed, Haitham M; Hazen, Stanley L

    2017-08-01

    Since identification of aspartate aminotransferase as the first cardiac biomarker in the 1950s, there have been a number of new markers used for myocardial damage detection over the decades. There have also been several generations of troponin assays, each with progressively increasing sensitivity for troponin detection. Accordingly, the "standard of care" for myocardial damage detection continues to change. The purpose of this paper is to review the clinical utility, biological mechanisms, and predictive value of these various biomarkers in contemporary clinical studies. As of this writing, a fifth "next" generation troponin assay has now been cleared by the US Food and Drug Administration for clinical use in the USA for subjects presenting with suspected acute coronary syndromes. Use of these high-sensitivity assays has allowed for earlier detection of myocardial damage as well as greater negative predictive value for infarction after only one or two serial measurements. Recent algorithms utilizing these assays have allowed for more rapid rule-out of myocardial infarction in emergency department settings. In this review, we discuss novel assays available for the risk assessment of subjects presenting with chest pain, including both the "next generation" cardiac troponin assays as well as other novel biomarkers. We review the biological mechanisms for these markers, and explore the positive and negative predictive value of the assays in clinical studies, where reported. We also discuss the potential use of these new markers within the context of future clinical care in the modern era of higher sensitivity troponin testing. Finally, we discuss advances in new platforms (e.g., mass spectrometry) that historically have not been considered for rapid in vitro diagnostic capabilities, but that are taking a larger role in clinical diagnostics, and whose prognostic value and power promise to usher in new markers with potential for future clinical utility in acute coronary

  13. Differential reactivities of four homogeneous assays for LDL-cholesterol in serum to intermediate-density lipoproteins and small dense LDL: comparisons with the Friedewald equation.

    Science.gov (United States)

    Yamashita, Shizuya; Kawase, Ryota; Nakaoka, Hajime; Nakatani, Kazuhiro; Inagaki, Miwako; Yuasa-Kawase, Miyako; Tsubakio-Yamamoto, Kazumi; Sandoval, Jose C; Masuda, Daisaku; Ohama, Tohru; Nakagawa-Toyama, Yumiko; Matsuyama, Akifumi; Nishida, Makoto; Ishigami, Masato

    2009-12-01

    In routine clinical laboratory testing and numerous epidemiological studies, LDL-cholesterol (LDL-C) has been estimated commonly using the Friedewald equation. We investigated the relationship between the Friedewald equation and 4 homogeneous assays for LDL-C. LDL-C was determined by 4 homogeneous assays [liquid selective detergent method: LDL-C (L), selective solubilization method: LDL-C (S), elimination method: LDL-C (E), and enzyme selective protecting method: LDL-C (P)]. Samples with discrepancies between the Friedewald equation and the 4 homogeneous assays for LDL-C were subjected to polyacrylamide gel electrophoresis and the beta-quantification method. The correlations between the Friedewald equation and the 4 homogeneous LDL-C assays were as follows: LDL-C (L) (r=0.962), LDL-C (S) (r=0.986), LDL-C (E) (r=0.946) and LDL-C (P) (r=0.963). Discrepancies were observed in sera from type III hyperlipoproteinemia patients and in sera containing large amounts of midband and small dense LDL on polyacrylamide gel electrophoresis. LDL-C (S) was most strongly correlated with the beta-quantification method even in sera from patients with type III hyperlipoproteinemia. Of the 4 homogeneous assays for LDL-C, LDL-C (S) exhibited the closest correlation with the Friedewald equation and the beta-quantification method, thus reflecting the current clinical databases for coronary heart disease.

  14. How does routinely delivered cognitive-behavioural therapy for gambling disorder compare to "gold standard" clinical trial?

    Science.gov (United States)

    Smith, David P; Fairweather-Schmidt, A Kate; Harvey, Peter W; Battersby, Malcolm W

    2018-03-01

    Currently, it is unknown whether treatment outcomes derived from randomized controlled trials (RCTs) of cognitive-behavioural therapy (CBT) for problem gamblers still hold when applied to patients seen in routine practice. Thus, data from an RCT of cognitive therapy versus exposure therapy for problem gambling versus patients of a gambling help service were compared. Assessments of problem gambling severity, psychosocial impairment, and alcohol use were undertaken at baseline and post-treatment and evaluated within a counterfactual framework. Findings showed that the contrast between routine CBT for pokies and horse betting had a significant effect, indicative of a 62% lower gambling urge score if routine CBT recipients had all been horse/track betters opposed to gambling with "pokies." However, the majority of contrasts indicated therapeutic outcomes achieved in routine CBT treatments were of equivalent robustness relative to RCT conditions. The present findings infer routine practice treatment outcomes are as efficacious as those generated in RCT contexts. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Should the lateral chest radiograph be routinely performed?

    International Nuclear Information System (INIS)

    Osman, Fatuma; Williams, Imelda

    2014-01-01

    Background: The chest x-ray is one of the most common plain film radiographic examinations performed. Inclusion of the lateral chest radiograph varies internationally and nationally across radiology departments and states in Australia. Search strategy: A search strategy of the databases Cochrane Library, Ovid Medline/Medline, PubMed, Scopus and Science Direct was conducted. The results were restricted to those published between 1985 and 2013 and those published in English. The following search terms were used: ‘lateral chest’, ‘radiograph’, ‘digital radiography’, ‘chest x-ray’, ‘plain film radiography’, ‘ionising radiation’. The results were restricted to publications with these terms in the title, abstract and/or keywords. Main findings: There are few national or international guidelines pertaining to the inclusion of the lateral chest x-ray as routine. Primary concerns are the increased radiation dose associated with the additional chest view and reduction of medical imaging services cost. Modern digital imaging systems result in a lower radiation dose. The diagnostic yield of the lateral chest x-ray is highly dependent on the clinical indications of the patient. Further research into the routine inclusion of the lateral chest x-ray is recommended. Conclusion: Review of the literature suggests that the lateral chest radiograph should not be performed routinely unless clinically indicated

  16. Alpha-fetoprotein in the routine clinical laboratory: evaluation of a simple radioimmunoassay and review of current concepts in its clinical application

    International Nuclear Information System (INIS)

    Brummund, W.; Mennuti, M.T.; Arvan, D.A.; Starkovsky, N.A.

    1980-01-01

    The authors have assessed the clinical utility of a radioimmunoassay for alpha-fetoprotein (AFP). The method, which relies on ammonium sulfate precipitation for the separation of 'bound' and 'free' radiolabeled antigen, can be completed in one working day. The assay is specific for AFP, has a sensitivity of <10 ng/ml, and has intra- and inter-assay precision of 5-8% and 9-11%, respectively. They have conducted a three-year study of 472 pregnancies in which physicians wished to detect neural tube defects, and of 400 non-pregnant patients to assess the value of serum AFP as a marker for certain benign and malignant diseases. Six of 6 fetal open neural-tube defects (NTD'S) and 3 of 3 intrauterine fetal deaths were correctly identified by their association with marked AFP elevations in both maternal serum and amniotic fluid. Thirty non-pregnant patients were found to have AFP elevations greater than 20 ng/ml. Malignancies associated with these elevations were hepatoma, germ cell tumors, Wilms' tumor, and carcinoma of unknown origin. Carcinoma metastatic to the liver was not associated with AFP elevations. In AFP-associated tumors they found serial measurements of serum AFP to be of value in assessing therapeutic response. (Auth.)

  17. Psychometric characteristics of Clinical Reasoning Problems (CRPs) and its correlation with routine multiple choice question (MCQ) in Cardiology department.

    Science.gov (United States)

    Derakhshandeh, Zahra; Amini, Mitra; Kojuri, Javad; Dehbozorgian, Marziyeh

    2018-01-01

    Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students' learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents' academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (preasoning in residents. It can be included in cardiology residency assessment programs.

  18. Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology

    NARCIS (Netherlands)

    Rossen, J. W. A.; Friedrich, A. W.; Moran-Gilad, J.

    Background: Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. Aim: To review the practical aspects of implementing bacterial

  19. Establishing optimal quantitative-polymerase chain reaction assays for routine diagnosis and tracking of minimal residual disease in JAK2-V617F-associated myeloproliferative neoplasms: a joint European LeukemiaNet/MPN&MPNr-EuroNet (COST action BM0902) study.

    Science.gov (United States)

    Jovanovic, J V; Ivey, A; Vannucchi, A M; Lippert, E; Oppliger Leibundgut, E; Cassinat, B; Pallisgaard, N; Maroc, N; Hermouet, S; Nickless, G; Guglielmelli, P; van der Reijden, B A; Jansen, J H; Alpermann, T; Schnittger, S; Bench, A; Tobal, K; Wilkins, B; Cuthill, K; McLornan, D; Yeoman, K; Akiki, S; Bryon, J; Jeffries, S; Jones, A; Percy, M J; Schwemmers, S; Gruender, A; Kelley, T W; Reading, S; Pancrazzi, A; McMullin, M F; Pahl, H L; Cross, N C P; Harrison, C N; Prchal, J T; Chomienne, C; Kiladjian, J J; Barbui, T; Grimwade, D

    2013-10-01

    Reliable detection of JAK2-V617F is critical for accurate diagnosis of myeloproliferative neoplasms (MPNs); in addition, sensitive mutation-specific assays can be applied to monitor disease response. However, there has been no consistent approach to JAK2-V617F detection, with assays varying markedly in performance, affecting clinical utility. Therefore, we established a network of 12 laboratories from seven countries to systematically evaluate nine different DNA-based quantitative PCR (qPCR) assays, including those in widespread clinical use. Seven quality control rounds involving over 21,500 qPCR reactions were undertaken using centrally distributed cell line dilutions and plasmid controls. The two best-performing assays were tested on normal blood samples (n=100) to evaluate assay specificity, followed by analysis of serial samples from 28 patients transplanted for JAK2-V617F-positive disease. The most sensitive assay, which performed consistently across a range of qPCR platforms, predicted outcome following transplant, with the mutant allele detected a median of 22 weeks (range 6-85 weeks) before relapse. Four of seven patients achieved molecular remission following donor lymphocyte infusion, indicative of a graft vs MPN effect. This study has established a robust, reliable assay for sensitive JAK2-V617F detection, suitable for assessing response in clinical trials, predicting outcome and guiding management of patients undergoing allogeneic transplant.

  20. Biochemical screening of 504,049 newborns in Denmark, the Faroe Islands and Greenland--experience and development of a routine program for expanded newborn screening

    DEFF Research Database (Denmark)

    Lund, Allan Meldgaard; Hougaard, David Michael; Simonsen, Henrik

    2012-01-01

    Expanded newborn screening for selected inborn errors of metabolism (IEM) in Denmark, the Faroe Islands and Greenland was introduced in 2002. We now present clinical, biochemical, and statistical results of expanded screening (excluding PKU) of 504,049 newborns during nine years as well as diagno......Expanded newborn screening for selected inborn errors of metabolism (IEM) in Denmark, the Faroe Islands and Greenland was introduced in 2002. We now present clinical, biochemical, and statistical results of expanded screening (excluding PKU) of 504,049 newborns during nine years as well...... as a pilot study during the first seven years, and the experience obtained during these years was used in the development of the routine neonatal screening program introduced in 2009. Methods for screening included tandem mass spectrometry and an assay for determination of biotinidase activity. A total...

  1. Radioprotective shield - an adequate radioprotective device for routine stomatological radiodiagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Wiltschke, F [Ernst-Moritz-Arndt-Univ., Greifswald (German Democratic Republic); Taschner, P; Koenig, W; Menzel, B [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic)

    1975-01-01

    Starting from the shortcomings of the radioprotective devices at present used in routine stomatological radiodiagnosis, the authors describe the advantages of a radioprotective shield which has been produced in the Greifswald University Stomatological Clinic. On the basis of dosimetric studies, the National Board for Nuclear Safety and Radiological Protection of the GDR (Staatliches Amt fuer Atomsicherheit und Strahlenschutz der DDR) could demonstrate the suitability of this shield as a radioprotective device for routine stomatological radiodiagnosis.

  2. [Use of PubMed to improve evidence-based medicine in routine urological practice].

    Science.gov (United States)

    Rink, M; Kluth, L A; Shariat, S F; Chun, F K; Fisch, M; Dahm, P

    2013-03-01

    Applying evidence-based medicine in daily clinical practice is the basis of patient-centered medicine and knowledge of accurate literature acquisition skills is necessary for informed clinical decision-making. PubMed is an easy accessible, free bibliographic database comprising over 21 million citations from the medical field, life-science journals and online books. The article summarizes the effective use of PubMed in routine urological clinical practice based on a common case scenario. This article explains the simple use of PubMed to obtain the best search results with the highest evidence. Accurate knowledge about the use of PubMed in routine clinical practice can improve evidence-based medicine and also patient treatment.

  3. Clinical value analysis of routine ultrasound combined with endoscopic ultrasonography in judging ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Jing-Mei Tuo

    2016-01-01

    Full Text Available Objective: To study the clinical value of routine ultrasound combined with endoscopic ultrasonography in judging ulcerative colitis. Methods: A total of 60 cases of patients with ulcerative colitis were collected as observation group of research and 60 cases of healthy volunteers were collected as control group of research. Intestinal wall thickness was detected by white light endoscopy, abdominal intestinal ultrasound and endoscopic ultrasonography; TNF-α, IL-1β, IL-4 and IL-10 contents were detected by Elisa kit; Th1, Th2, Th17 and Treg ratios were detected by flow cytometry. Results: (1 intestinal wall thickness: intestinal wall thickness of both active UC patients and quiescent UC patients was significantly higher than that of control group, intestinal wall thickness of active UC patients was significantly higher than that of quiescent UC patients and the higher the degree of activity, the higher the intestinal wall thickness; (2 inflammatory mediators: TNF-α and IL-1β contents in intestinal mucosa of active UC patients were higher than those of quiescent UC patients and positively correlated with intestinal wall thickness; IL-4 and IL-10 contents were lower than those of quiescent UC patients and negatively correlated with intestinal wall thickness; (3 T cell contents: Th1 and Th17 cell contents in intestinal mucosa of active UC patients were higher than those of quiescent UC patients and positively correlated with intestinal wall thickness; Th2 and Treg cell contents in intestinal mucosa of active UC patients were lower than those of quiescent UC patients and negatively correlated with intestinal wall thickness. Conclusion: Routine ultrasound combined with endoscopic ultrasonography can accurately determine the severity of ulcerative colitis; measured intestinal wall thickness is closely correlated with the degree of inflammation and abnormal immune response.

  4. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences.

    Science.gov (United States)

    Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R

    2016-12-01

    Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.

  5. Practical Issues in Implementing Whole-Genome-Sequencing in Routine Diagnostic Microbiology

    NARCIS (Netherlands)

    Rossen, John W A; Friedrich, Alexander W; Moran-Gilad, Jacob

    BACKGROUND: next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology that is being adopted in microbiology, the integration of NGS into clinical and routine workflows needs to be carefully managed. AIM: to review the practical aspects of

  6. Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

    Science.gov (United States)

    Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko

    2015-01-01

    Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.

  7. Clinical evaluation of a loop-mediated isothermal amplification (LAMP assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

    Directory of Open Access Journals (Sweden)

    DoKyung Lee

    Full Text Available Neisseria meningitidis (Nm is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF.We developed a meningococcal LAMP assay (Nm LAMP that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR. The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively.Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.

  8. Internet-based CBT for social phobia and panic disorder in a specialised anxiety clinic in routine care: Results of a pilot randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Kim Mathiasen

    2016-05-01

    This study was not able to document statistically significant clinical effect of iCBT with minimal therapist contact compared to a waiting list control group in a specialised anxiety clinic in routine care. However, a large and significant effect was seen on self-reported quality of life. Although these results offer an interesting perspective on iCBT in specialised care, they should be interpreted with caution, due to the limitations of the study. A large scale fully powered RCT is recommended.

  9. “There Are Too Many, but Never Enough": Qualitative Case Study Investigating Routine Coding of Clinical Information in Depression

    Science.gov (United States)

    Cresswell, Kathrin; Morrison, Zoe; Sheikh, Aziz; Kalra, Dipak

    2012-01-01

    Background We sought to understand how clinical information relating to the management of depression is routinely coded in different clinical settings and the perspectives of and implications for different stakeholders with a view to understanding how these may be aligned. Materials and Methods Qualitative investigation exploring the views of a purposefully selected range of healthcare professionals, managers, and clinical coders spanning primary and secondary care. Results Our dataset comprised 28 semi-structured interviews, a focus group, documents relating to clinical coding standards and participant observation of clinical coding activities. We identified a range of approaches to coding clinical information including templates and order entry systems. The challenges inherent in clearly establishing a diagnosis, identifying appropriate clinical codes and possible implications of diagnoses for patients were particularly prominent in primary care. Although a range of managerial and research benefits were identified, there were no direct benefits from coded clinical data for patients or professionals. Secondary care staff emphasized the role of clinical coders in ensuring data quality, which was at odds with the policy drive to increase real-time clinical coding. Conclusions There was overall no evidence of clear-cut direct patient care benefits to inform immediate care decisions, even in primary care where data on patients with depression were more extensively coded. A number of important secondary uses were recognized by healthcare staff, but the coding of clinical data to serve these ends was often poorly aligned with clinical practice and patient-centered considerations. The current international drive to encourage clinical coding by healthcare professionals during the clinical encounter may need to be critically examined. PMID:22937106

  10. Line probe assay for differentiation within Mycobacterium tuberculosis complex. Evaluation on clinical specimens and isolates including Mycobacterium pinnipedii

    DEFF Research Database (Denmark)

    Kjeldsen, Marianne Kirstine; Bek, Dorte; Rasmussen, Erik Michael

    2009-01-01

    A line probe assay (GenoType MTBC) was evaluated for species differentiation within the Mycobacterium tuberculosis complex (MTBC). We included 387 MTBC isolates, 43 IS6110 low-copy MTBC isolates, 28 clinical specimens with varying microscopy grade, and 30 isolates of non-tuberculous mycobacteria...

  11. Micro-enzyme-linked immunosorbent assay (ELISA) and radioimmunosorbent technique (RIST) for the detection of immunity to clinical tetanus

    Energy Technology Data Exchange (ETDEWEB)

    Layton, G T [Royal Infirmary, Manchester (UK)

    1980-10-01

    Enzyme-linked immunosorbent assay (ELISA), and radioimmunosorbent assay (RIST) techniques for the detection of tetanus toxin antibodies are described. Both methods proved to be highly sensitive, and allowed the measurement of 5 x 10/sup -3/ units/ml tetanus antitoxin in human serum or plasma, sensitivity and reproducibility comparing well with other techniques previously described, and being superior to haemagglutination and latex agglutination tests. Results of the two methods correlated well, and reflected the immunization histories obtained. Micro ELISA and micro RIST would seem to be suitable for the detection of immunity, or non-immunity to clinical tetanus.

  12. Falsely low immunoglobulin (Ig)G4 in routine analysis: how not to miss IgG4 disease.

    Science.gov (United States)

    Egner, W; Swallow, K; Lock, R J; Patel, D

    2016-10-01

    Immunoglobulin (Ig)G4 disease can have apparently 'normal' levels of IgG4 due to antigen excess conditions. IgG4 measurement therefore appears falsely low. UK National External Quality Assurance Scheme (UK NEQAS) data and other reports have suggested that this problem occurred despite pre-existing antigen excess detection steps. To determine the clinical relevance of the problem, we examined the prevalence and characteristics of prozoning in our laboratory and patient cohorts. We establish that the prevalence of raised IgG4 in routine IgG4 analysis is low (IgG4 samples in our patients. This may explain the previous reports of low sensitivity of raised IgG4 for IgG4RD, and predictive values should be re-evaluated in this disease using modified prozone-resistant protocols. All laboratories providing IgG4 measurements should verify that their assays are fit for the clinical quality requirement of detection raised IgG4 levels and must verify the upper limit of their reference ranges and freedom from prozoning. © 2016 British Society for Immunology.

  13. How often do head and neck cancer patients raise concerns related to intimacy and sexuality in routine follow-up clinics?

    Science.gov (United States)

    Rogers, S N; Hazeldine, P; O'Brien, K; Lowe, D; Roe, B

    2015-01-01

    Intimacy and sexuality problems are underreported in head and neck cancer patients. The aim of this study was to collate the various prompts available in a routine follow-up clinic through the use of an intimacy screening question and Patient's Concerns Inventory (PCI), and to identify how often these problems were raised by patients and what possible actions took place as a consequence. 177 patients completed the intimacy screening question, PCI and UW-QOLv.4 at follow-up clinics, from October 2008 to January 2011. Case note review identified if intimacy was mentioned in clinic letters and if referral for support was made. On the intimacy screening question, 15 % (26) reported problems of considerable/some concern (24) or selected intimacy/sexuality on the PCI (2). The PCI identified that 9 of the 24 reporting the worst problems wanted the topic discussed in clinic, and clinic letters suggested that 5 of these discussed the issue in clinic with 4 being referred on, 3 to a clinical psychologist and 1 to a clinical nurse specialist. Intimacy problems are underreported in clinic reviews. It is a difficult subject to discuss. It will remain a potential unmet need unless attempts are made to advance the opportunities for patient screening, information leaflets, staff training on how to talk about such sensitive issues and referral for counselling.

  14. Cyclotrons, radionuclides, precursors, and demands for routine versus research compounds

    International Nuclear Information System (INIS)

    Wolf, A.P.

    1984-01-01

    Accelerators for producing commonly used short-lived positron emitters for positron emission tomography are addressed in the context of their use for the preparation of labeled compounds for research and routine biomedical applications. Progress and direction in the preparation and use of radiotracers for studies of the brain are discussed. Advancement to complete automation is stressed as an important factor for the eventual use of positron emission tomography as a routine clinical tool in universities and major medical centers

  15. Clinical utility of an optimised multiplex real-time PCR assay for the identification of pathogens causing sepsis in Vietnamese patients

    Directory of Open Access Journals (Sweden)

    Ngo Tat Trung

    2018-02-01

    Conclusion: The combination of culture and the multiplex RT-PCR assay provided an excellent diagnostic accomplishment and significantly supported the identification of causative pathogens in clinical samples obtained from septic patients.

  16. Role of genotype® mycobacterium common mycobacteria/additional species assay for rapid differentiation between Mycobacterium tuberculosis complex and different species of non-tuberculous mycobacteria

    Directory of Open Access Journals (Sweden)

    Amresh Kumar Singh

    2013-01-01

    Full Text Available Background: Mycobacterium tuberculosis complex (MTBC and non-tuberculous mycobacteria (NTM may or may not have same clinical presentations, but the treatment regimens are always different. Laboratory differentiation between MTBC and NTM by routine methods are time consuming and cumbersome to perform. We have evaluated the role of GenoType® Mycobacterium common mycobacteria/additional species (CM/AS assay for differentiation between MTBC and different species of NTM in clinical isolates from tuberculosis (TB cases. Materials and Methods: A total of 1080 clinical specimens were collected from January 2010 to June 2012. Diagnosis was performed by Ziehl-Neelsen staining followed by culture in BacT/ALERT 3D system (bioMerieux, France. A total of 219 culture positive clinical isolates (BacT/ALERT® MP cultures were selected for differentiation by p-nitrobenzoic acid (PNB sensitivity test as and BIO-LINE SD Ag MPT64 TB test considering as the gold standard test. Final identification and differentiation between MTBC and different species of NTM were further confirmed by GenoType® Mycobacterium CM/AS assay (Hain Lifescience, Nehren, Germany. Results: Out of 219 BacT/ALERT® MP culture positive isolates tested by PNB as 153 MTBC (69.9% and by GenoType® Mycobacterium CM/AS assay as 159 (72.6% MTBC and remaining 60 (27.4% were considered as NTM species. The GenoType® Mycobacterium CM/AS assay was proved 99.3% sensitive and 98.3% specific for rapid differentiation of MTBC and NTM. The most common NTM species were; Mycobacterium fortuitum 20 (33.3% among rapid growing mycobacteria and Mycobacterium intracellulare 11 (18.3% among slow growing mycobacteria. Conclusion: The GenoType® Mycobacterium assay makes rapid and accurate identification of NTM species as compared with different phenotypic and molecular diagnostic tool and helps in management of infections caused by different mycobacteria.

  17. Report of the consultants' meeting on radioimmunometric assays for non-clinical applications

    International Nuclear Information System (INIS)

    2000-01-01

    A meeting between three experts and various Agency staff with specific areas of expertise was convened to review present status of radiolabelled immunoassays i.e. radioimmunoassay (RIA) and immunradiometric assay (IRMA) and their relevance to non- clinical applications. For many years, the Agency has been active in supporting the devolution of RIA and IRMA expertise in clinical applications, particularly in the field of thyroid disease and its management. The Agency's strategy was based on a perceived need to reduce the high cost of imported reagents and the poor working practices that this encouraged. This has been achieved through the use of bulk reagents (rather than 'kits') and the transfer of existing technology. The success of the Agency's approach is evident from the high degree of self- sufficiency now available in many developing countries. In recent years, the increasing workload for clinical analyses has necessitated an increase in automation, which in turn has required a change to more non-isotopic alternatives. This change seen in the more developed countries, and beginning to be introduced elsewhere, is likely lo continue. However, RIA/IRMA will continue to be used in many parts of the world for some time to come. In recent years there has been an increasing interest in the use of immunoassay technology in non-clinical applications, e.g., environmental monitoring, quality control in food production and livestock management. RIA and IRMA continue to play a major role in research

  18. Daily medication routine of adolescents with HIV/AIDS

    Directory of Open Access Journals (Sweden)

    Cristiane Cardoso de Paula

    2013-12-01

    Full Text Available The objective of this study was to describe the sociodemographic, clinical, and behavioral characteristics of the daily medication routine of adolescents with HIV/AIDS of ages 13 to 19 years, followed at a reference service. This descriptive cross-sectional study was performed with 23 adolescents, using a quantitative approach. Data were collected using a form during appointments at the outpatient clinic. Univariate analysis revealed: females, in the initial phase of adolescence, and vertical transmission. The highlights were: lack of assiduity to appointments; unprotected sex; and consumption of alcohol. Regarding the daily medication routine, subjects depend on their parents or guardians, use strategies to remember to take the medications, and are unaware about the laboratory test for disease management and treatment. There is a need for educative intervention using information and communication technology, such as the Internet, to promote health and autonomy among adolescents. Descriptors: Acquired Immunodeficiency Syndrome; Adolescent Health; Antiretroviral Therapy, Highly Active; Nursing.

  19. Chemical restraint in routine clinical practice: a report from a general hospital psychiatric ward in Greece

    Directory of Open Access Journals (Sweden)

    Papamichael Georgios

    2011-02-01

    Full Text Available Abstract Background There is a dearth of studies regarding chemical restraint in routine clinical psychiatric practice. There may be wide variations between different settings and countries. Methods A retrospective study on chemical restraint was performed in the 11-bed psychiatric ward of the General Hospital of Arta, in northwestern Greece. All admissions over a 2-year-period (from March 2008 to March 2010 were examined. Results Chemical restraint was applied in 33 cases (10.5% of total admissions. From a total of 82 injections, 22 involved a benzodiazepine and/or levomepromazine, whereas 60 injections involved an antipsychotic agent, almost exclusively haloperidol (96.7% of cases, usually in combination with a benzodiazepine (61.7% of cases. In 36.4% of cases the patient was further subjected to restraint or seclusion. Conclusions In our unit, clinicians prefer the combined antipsychotic/benzodiazepine regimen for the management of patients' acute agitation and violent behaviour. Conventional antipsychotics are administrated almost exclusively and in a significant proportion of cases further coercive measures are applied. Studies on the practice of chemical restraint should be regularly performed in clinical settings.

  20. Brand-to-generic levetiracetam switch in patients with epilepsy in a routine clinical setting.

    Science.gov (United States)

    Markoula, Sofia; Chatzistefanidis, Dimitrios; Gatzonis, Stylianos; Siatouni, Anna; Siarava, Eleftheria; Verentzioti, Anastasia; Kyritsis, Athanassios P; Patsalos, Philip N

    2017-05-01

    The therapeutic equivalence of generic and brand antiepileptic drugs, based on studies performed on healthy volunteers, has been questioned. We compare, in a routine clinical setting, brand versus generic levetiracetam (LEV) bioequivalence in patients with epilepsy and also the clinical efficacy and tolerability of the substitution. A prospective, open-label, non-randomized, steady-state, multiple-dose, bioequivalence study was conducted in 12 patients with epilepsy (5 females), with a mean age of 38.4±16.2 years. Patients treated with the brand LEV (Keppra; UCB Pharma) were closely followed for a four-week period and subsequently switched to a generic LEV (Pharmaten) and followed for another four-week period. Blood samples were collected at the end of each 4-week period, during a dose interval for each formulation, for LEV concentration measurements by liquid chromatography mass spectrometry. Steady-state area under the curve (AUC) and peak plasma concentration (Cmax) data were subjected to conventional average bioequivalence analysis. Secondary clinical outcomes, including seizure frequency and adverse events, were recorded. Patients had epilepsy for a mean period of 14.1±10.6years and the mean daily LEV dose was 2583.3±763.7mg. The mean AUC±SD and Cmax±SD was 288.4±86.3(mg/L)h and 37.8±10.4mg/L respectively for brand LEV and 319.2±104.7(mg/L)h and 41.6±12.3mg/L respectively for the generic LEV. Statistic analysis showed no statistical significant difference in bioequivalence. Also, no change in seizures frequency and/or adverse events was recorded. In our clinical setting, generic LEV was determined to be bioequivalent to brand LEV. Furthermore, seizures frequency or/and adverse events were not affected upon switching from brand to generic LEV. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  1. Multidrug-resistant tuberculosis: Rapid molecular detection with MTBDRplus® assay in clinical samples

    Directory of Open Access Journals (Sweden)

    Rita Macedo

    2009-05-01

    Full Text Available Nowadays, the greatest concern of tuberculosis control programmes is the appearance of multidrug-resistant tuberculosis and extensively drug-resistant tuberculosis. Rapid determination of drug resistance in clinical samples, with Mycobacterium tuberculosis complex (MTC, is the prerequisite for initiating effective chemotherapy, ensuring successful treatment of the patient and preventing further spread of drugresistant isolates.The aim of our study was to determine the sensitivity of the new MTBDRplus® assay in comparison to culture, identification and classic DST, directly from smear-positive clinical specimens.A total of 68 smear-positive sputum specimens were processed by both the classical mycobacteriological methods and the molecular assay, MTBDRplus®.MTBDRplus® assay allowed an accurate identification of MTC species by detection of the specific band in all samples, from which we also isolated and identified MTC strains by culture methods. In the samples from which we isolated susceptible strains (63.2%, wild type patterns were found using MTBDRplus® assay. The samples from which we isolated resistant strains (36.8% showed specific mutations associated with the correspondent resistant phenotype.Our study indicated that this assay allows rapid detection of resistance, always in agreement with classic methods. Resumo: Uma das principais problematicas no controlo da tuberculose e o aparecimento de casos de tuberculose multirresistente (TB-MR e tuberculose extensivamente resistente (TB-XDR. A deteccao precoce da resistencia a farmacos, directamente a partir de amostras respiratorias, e essencial para que se assegure o tratamento atempado, adequado e eficaz da tuberculose, bem como para prevenir a disseminacao destes casos de especial gravidade.O nosso objectivo foi avaliar a sensibilidade e comparar os resultados obtidos com um metodo de genetica molecular disponivel comercialmente – MTBDRplus® – e o isolamento

  2. Method for assay of radioactivity in waste soil

    International Nuclear Information System (INIS)

    Bramlitt, E.T.; Willhoite, S.B.

    1991-01-01

    Contaminated soil is a result of many nuclear operations. During facility decommissioning or site cleanup, it may be packaged for disposal. The waste soil must be assayed for contaminants to follow transport regulations and waste handling facility requirements. Methods used for assay include the following: (1) sampling the ground before excavation and assuming ground data apply to soil when packaged; (2) analyzing samples taken from the soil added to a package; (3) counting radiation at the exterior of the package; and (4) measuring neutron absorption by packaged waste soil. The Defense Nuclear Agency (DNA) worked with Eberline Instruments Corporation (EIC) to develop an automated assay method for the waste stream in a plutonium-contaminated soil cleanup at Johnston Atoll in the North Pacific Ocean. The perfected method uses a personal computer, an electronic weighing scale, and a programmable radiation counter. Computer programs get weight and radiation counts at frequent intervals as packages fill, calculate activity in the waste, and produce reports. The automated assay method is an efficient one-person routine that steadfastly collects data and produces a comprehensive record on packaged waste

  3. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  4. Clinical diagnosis and typing of systemic amyloidosis in subcutaneous fat aspirates by mass spectrometry-based proteomics.

    Science.gov (United States)

    Vrana, Julie A; Theis, Jason D; Dasari, Surendra; Mereuta, Oana M; Dispenzieri, Angela; Zeldenrust, Steven R; Gertz, Morie A; Kurtin, Paul J; Grogg, Karen L; Dogan, Ahmet

    2014-07-01

    Examination of abdominal subcutaneous fat aspirates is a practical, sensitive and specific method for the diagnosis of systemic amyloidosis. Here we describe the development and implementation of a clinical assay using mass spectrometry-based proteomics to type amyloidosis in subcutaneous fat aspirates. First, we validated the assay comparing amyloid-positive (n=43) and -negative (n=26) subcutaneous fat aspirates. The assay classified amyloidosis with 88% sensitivity and 96% specificity. We then implemented the assay as a clinical test, and analyzed 366 amyloid-positive subcutaneous fat aspirates in a 4-year period as part of routine clinical care. The assay had a sensitivity of 90%, and diverse amyloid types, including immunoglobulin light chain (74%), transthyretin (13%), serum amyloid A (%1), gelsolin (1%), and lysozyme (1%), were identified. Using bioinformatics, we identified a universal amyloid proteome signature, which has high sensitivity and specificity for amyloidosis similar to that of Congo red staining. We curated proteome databases which included variant proteins associated with systemic amyloidosis, and identified clonotypic immunoglobulin variable gene usage in immunoglobulin light chain amyloidosis, and the variant peptides in hereditary transthyretin amyloidosis. In conclusion, mass spectrometry-based proteomic analysis of subcutaneous fat aspirates offers a powerful tool for the diagnosis and typing of systemic amyloidosis. The assay reveals the underlying pathogenesis by identifying variable gene usage in immunoglobulin light chains and the variant peptides in hereditary amyloidosis. Copyright© Ferrata Storti Foundation.

  5. Improved laboratory assays of Pu and U for SRP purification and finishing processes

    International Nuclear Information System (INIS)

    Holland, M.K.; Dorsett, R.S.

    1986-01-01

    Significant improvements have been made in routine assay techniques for uranium and plutonium as part of an effort to improve accountability at the Savannah River Plant (SRP). Emphasis was placed on input/output accountability points and key physical inventory tanks associated with purification and finishing processes. Improvements were made in existing assay methods; new methods were implemented; and the application of these methods was greatly expanded. Prior to assays, samples were validated via density measurements. Digital density meters precise to four, five, and six decimal places were used to meet specific requirements. Improved plutonium assay techniques are now in routine use: controlled-potential coulometry, ion-exchange coulometry, and Pu(III) diode-array spectrophotometry. A new state-of-the-art coulometer was fabricated and used to ensure maximum accuracy in verifying standards and in measuring plutonium in product streams. The diode-array spectrophotometer for Pu(III) measurements was modified with fiber optics to facilitate remote measurements; rapid, precise measurements made the technique ideally suited for high-throughput assays. For uranium assays, the isotope-dilution mass spectrometric (IDMS) method was converted to a gravimetric basis. The IDMS method and the existing Davies-Gray titration (gravimetric basis) have met accountability requirements for uranium. More recently, a Pu(VI) diode-array spectrophotometric method was used on a test basis to measure plutonium in shielded-cell input accountability samples. In addition, tests to measure uranium via diode-array spectrophotometry were initiated. This rapid, precise method will replace IDMS for certain key sample points

  6. Acceptance and commitment therapy (ACT) for clinically distressed health care workers: Waitlist-controlled evaluation of an ACT workshop in a routine practice setting.

    Science.gov (United States)

    Waters, Cerith S; Frude, Neil; Flaxman, Paul E; Boyd, Jane

    2018-03-01

    To examine the effects of a 1-day acceptance and commitment therapy (ACT) workshop on the mental health of clinically distressed health care employees, and to explore ACT's processes of change in a routine practice setting. A quasi-controlled design, with participants block allocated to an ACT intervention or waiting list control group based on self-referral date. Participants were 35 health care workers who had self-referred for the ACT workshop via a clinical support service for staff. Measures were completed by ACT and control group participants at pre-intervention and 3 months post-intervention. Participants allocated to the waitlist condition went on to receive the ACT intervention and were also assessed 3 months later. At 3 months post-intervention, participants in the ACT group reported a significantly lower level of psychological distress compared to the control group (d = 1.41). Across the 3-month evaluation period, clinically significant change was exhibited by 50% of ACT participants, compared to 0% in the control group. When the control group received the same ACT intervention, 69% went on to exhibit clinically significant change. The ACT intervention also resulted in significant improvements in psychological flexibility, defusion, and mindfulness skills, but did not significantly reduce the frequency of negative cognitions. Bootstrapped mediation analyses indicated that the reduction in distress in the ACT condition was primarily associated with an increase in mindfulness skills, especially observing and non-reactivity. These findings provide preliminary support for providing brief ACT interventions as part of routine clinical support services for distressed workers. A 1-day ACT workshop delivered in the context of a routine staff support service was effective for reducing psychological distress among health care workers. The brief nature of this group intervention means it may be particularly suitable for staff support and primary care mental

  7. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    Science.gov (United States)

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  8. A multiplex PCR/LDR assay for simultaneous detection and identification of the NIAID category B bacterial food and water-borne pathogens.

    Science.gov (United States)

    Rundell, Mark S; Pingle, Maneesh; Das, Sanchita; Hussain, Aashiq; Ocheretina, Oksana; Charles, Macarthur; Larone, Davise H; Spitzer, Eric D; Golightly, Linnie; Barany, Francis

    2014-06-01

    Enteric pathogens that cause gastroenteritis remain a major global health concern. The goal of this study was to develop a multiplex PCR/ligation detection reaction (LDR) assay for the detection of all NIAID category B bacterial food and water-borne pathogens directly from stool specimens. To validate the PCR/LDR assay, clinical isolates of Campylobacter spp., Vibrio spp., Shigella spp., Salmonella spp., Listeria monocytogenes, Yersinia enterocolitica, and diarrheagenic Escherichia coli were tested. The sensitivity and specificity of the assay were assessed using a large number of seeded culture-negative stool specimens and a smaller set of clinical specimens from Haiti. The overall sensitivity ranged from 91% to 100% (median 100%) depending on the species. For the majority of organisms, the sensitivity was 100%. The overall specificity based on initial testing ranged from 98% to 100% depending on the species. After additional testing of discordant samples, the lowest specificity was 99.4%. PCR/LDR detected additional category B agents (particularly diarrheagenic E. coli) in 11/40 specimens from Haiti that were culture-positive for V. cholerae and in approximately 1% of routine culture-negative stool specimens from a hospital in New York. This study demonstrated the ability of the PCR/LDR assay to detect a large comprehensive panel of category B enteric bacterial pathogens as well as mixed infections. This type of assay has the potential to provide earlier warnings of possible public health threats and more accurate surveillance of food and water-borne pathogens. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Patients' experiences with routine outcome monitoring and clinical feedback systems: A systematic review and synthesis of qualitative empirical literature.

    Science.gov (United States)

    Solstad, Stig Magne; Castonguay, Louis Georges; Moltu, Christian

    2017-05-19

    Routine outcome monitoring (ROM) and clinical feedback (CF) systems have become important tools for psychological therapies, but there are challenges for their successful implementation. To overcome these challenges, a greater understanding is needed about how patients experience the use of ROM/CF. We conducted a systematic literature search of qualitative studies on patient experiences with the use of ROM/CF in mental health services. The findings from 16 studies were synthesized, resulting in four meta-themes: (1) Suspicion towards service providers, (2) Flexibility and support to capture complexity, (3) Empowering patients, and (4) Developing collaborative practice. We discuss the implications of these meta-themes for further development and implementation of ROM/CF into clinical practice, acknowledging the limitations of our review and suggesting avenues for further research. Clinical or methodological significance of this article: This article provides useful and actionable knowledge about the patient perspective on ROM/CF, an important discussion on the current state of research in this area, and useful and concrete suggestions for further avenues of research.

  10. PTH Assays: Understanding What We Have and Forecasting What We Will Have

    Directory of Open Access Journals (Sweden)

    Jose Gilberto H. Vieira

    2012-01-01

    Full Text Available Parathyroid hormone (PTH assays have evolved continuously for the last 50 years. Since the first radioimmunoassay was described in 1963, several assays based on immunological identification have been published (first generation assays. The routine assays used nowadays are immunometric “sandwich-type”. They are based on two different monoclonal antibodies, one amino-terminal and the other carboxyl terminal specific. These second generation assays are widely available and adapted to most of the automation platforms. The specificity of the amino terminal antibody defines if the immunometric assay measures only the bioactive PTH circulating form (including the first amino terminal amino acids or the “intact” PTH, which includes, besides bioactive PTH, other “long” carboxyl-terminal forms, for example, 7–84-PTH. Assays for “intact” PTH are the most commonly available and the potential advantage of the bioactive PTH assays is still debatable. Next generation of assays will be based on different principles, mainly mass spectrometry in samples submitted to a prior purification and fragmentation steps. These assays will provide information about the whole spectra of PTH peptides in circulation, with a significant increase of the information regarding this biologically important peptide hormone.

  11. Is routine antenatal venereal disease research laboratory test still justified? Nigerian experience

    Directory of Open Access Journals (Sweden)

    Nwosu BO

    2015-01-01

    Full Text Available Betrand O Nwosu,1 George U Eleje,1 Amaka L Obi-Nwosu,2 Ita F Ahiarakwem,3 Comfort N Akujobi,4 Chukwudi C Egwuatu,4 Chukwudumebi O Onyiuke5 1Department of Obstetrics and Gynecology, Nnamdi Azikiwe University, Nnewi Campus, Nnewi, Anambra State, Nigeria; 2Department of Family Medicine, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria; 3Department of Medical Microbiology, Imo State University Teaching Hospital, Orlu, Imo State, Nigeria; 4Department of Medical Microbiology, Nnamdi Azikiwe University, Nnewi Campus, Nnewi, Anambra State, Nigeria; 5Department of Medical Microbiology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, NigeriaObjective: To determine the seroreactivity of pregnant women to syphilis in order to justify the need for routine antenatal syphilis screening.Methods: A multicenter retrospective analysis of routine antenatal venereal disease research laboratory (VDRL test results between 1 September 2010 and 31 August 2012 at three specialist care hospitals in south-east Nigeria was done. A reactive VDRL result is subjected for confirmation using Treponema pallidum hemagglutination assay test. Analysis was by Epi Info 2008 version 3.5.1 and Stata/IC version 10.Results: Adequate records were available regarding 2,156 patients and were thus reviewed. The mean age of the women was 27.4 years (±3.34, and mean gestational age was 26.4 weeks (±6.36. Only 15 cases (0.70% were seropositive to VDRL. Confirmatory T. pallidum hemagglutination assay was positive in 4 of the 15 cases, giving an overall prevalence of 0.19% and a false-positive rate of 73.3%. There was no significant difference in the prevalence of syphilis in relation to maternal age and parity (P>0.05.Conclusion: While the prevalence of syphilis is extremely low in the antenatal care population at the three specialist care hospitals in south-east Nigeria, false-positive rate is high and prevalence did not significantly vary with maternal age or

  12. Noninvasive Personalization of Lung Cancer Therapy Using a New, Clinical-Grade Assay for Plasma-Based Measurement and Monitoring of Tumor Genotype

    Science.gov (United States)

    2016-12-01

    funding to launch our plasma assay as a clinical test at Brigham and Women’s Hospital . With this assay, I have launched an investigator-sponsored trial...Manager [Recently Completed] Phi Beta Psi Charity Trust (Oxnard) 08/15/14 – 08/14/16 *0.00 CM Non-invasive genotyping realized at last...Harvard University, MA BA 06/1999 Chemistry University of Chicago, Pritzker School of Medicine, IL MD 06/2005 Medicine Massachusetts General Hospital

  13. Lactase Non-Persistence Genotyping: Comparison of Two Real-Time PCR Assays and Assessment of Concomitant Fructose/Sorbitol Malabsorption Rates.

    Science.gov (United States)

    Enko, Dietmar; Pollheimer, Verena; Németh, Stefan; Pühringer, Helene; Stolba, Robert; Halwachs-Baumann, Gabriele; Kriegshäuser, Gernot

    2016-01-01

    Genetic testing is a standard technique for the diagnosis of primary adult-type hypolactasia, also referred to as lactase non-persistence. The aim of this study was to compare the lactase gene (LCT) C/T-13910 polymorphism genotyping results of two commercially available real-time (RT)-PCR assays in patients referred to our outpatient clinic for primary lactose malabsorption testing. Furthermore, concomitant conditions of fructose/sorbitol malabsorption were assessed. Samples obtained from 100 patients were tested in parallel using the LCT T-13910C ToolSet for Light Cycler (Roche, Rotkreuz, Switzerland) and the LCT-13910C>T RealFast Assay (ViennaLab Diagnostics GmbH, Vienna, Austria). Additionally, patients were also screened for the presence of fructose/sorbitol malabsorption by functional hydrogen (H2)/methane (CH4) breath testing (HMBT). Cohen's Kappa (κ) was used to calculate the agreement between the two genotyping methods. The exact Chi-Square test was performed to compare fructose/sorbitol HMBT with LCT genotyping results. Twenty-one (21.0%) patients had a LCT C/C-13910 genotype suggestive of lactase non-persistence, and 79 (79.0%) patients were identified with either a LCT T/C-13910 or T/T-13910 genotype (i.e., lactase persistence). In all genotype groups, concordance between the two RT-PCR assays was 100%. Cohen's κ demonstrated perfect observed agreement (p sorbitol malabsorption was observed in 13/100 (13.0%) and 25/100 (25.0%) individuals, respectively. Both RT-PCR assays are robust and reliable LCT genotyping tools in a routine clinical setting. Concomitant fructose and/or sorbitol malabsorption should be considered in individuals with suspected lactase-non-persistence. However, standardization of clinical interpretation of laboratory HMBT results is required.

  14. Computer-aided diagnosis in routine mammography

    International Nuclear Information System (INIS)

    Sittek, H.; Perlet, C.; Helmberger, R.; Linsmeier, E.; Kessler, M.; Reiser, M.

    1998-01-01

    Purpose: Computer-aided diagnosis in mammography is a topic many study groups have been concerned with since the first presentation of a system for computer-aided interpretation in 1967. Currently, there is only one system avilable for clinical use in mammography, the CAD-System Image Checker (R2 Technology). The purpose of our prospective study was to evaluate whether the integration of the CAD-system into the routine of a radiological breast diagnosis unit is feasible. Results: After the installation of the CAD-system, 300 patients with 1110 mammograms were included for evaluation in the present study. In 54 of these cases histological examination was indicated due to suspect criteria on conventional mammography. In 39 of 54 cases (72,2%) malignancy could be proven histologically. The CAD-system marked 82,1% of the histologically verified carcinomas correctly 94,3% of all 1797 marks made by the CAD-system indicated normal or benign structures. Routinely performed CAD analysis prolonged patients waiting time by about 15 min because the marks of the CAD system had to be interpreted in addition to the routine diagnostic investigations. Conclusion: Our experience with the use of the CAD-system in daily routine showed that CAD analysis can easily be integrated into a preexisting mammography unit. However, the diagnostic benefit is not yet clearly established. Since the rate of false negative marks by the CAD-system Image Checker is still high, the results of CAD analysis must be checked and corrected by an observer well experienced in mammography reading. (orig.) [de

  15. Prometheus: the implementation of clinical coding schemes in French routine general practice

    Directory of Open Access Journals (Sweden)

    Laurent Letrilliart

    2006-09-01

    Conclusions Coding health problems on a routine basis proved to be feasible. However, this process can be used on a more widespread basis and linked to other management data only if physicians are specially trained and rewarded, and the software incorporates large terminologies mapped with classifications.

  16. Use of GenoType® MTBDRplus assay to assess drug resistance and mutation patterns of multidrug-resistant tuberculosis isolates in northern India

    Directory of Open Access Journals (Sweden)

    A K Maurya

    2013-01-01

    Full Text Available Purpose: The emergence and spread of multidrug-resistant tuberculosis (MDR-TB is a major public health problem. The diagnosis of MDR-TB is of paramount importance in establishing appropriate clinical management and infection control measures. The aim of this study was to evaluate drug resistance and mutational patterns in clinical isolates MDR-TB by GenoType® MTBDRplus assay. Material and Methods: A total of 350 non-repeated sputum specimens were collected from highly suspected drug-resistant pulmonary tuberculosis (PTB cases; which were processed by microscopy, culture, differentiation and first line drug susceptibility testing (DST using BacT/ALERT 3D system. Results: Among a total of 125 mycobacterium tuberculosis complex (MTBC strains, readable results were obtained from 120 (96% strains by GenoType® MTBDRplus assay. Only 45 MDR-TB isolates were analysed for the performance, frequency and mutational patterns by GenoType® MTBDRplus assay. The sensitivity of the GenoType® MDRTBplus assay for detecting individual resistance to rifampicin (RIF, isoniazid (INH and multidrug resistance was found to be 95.8%, 96.3% and 97.7%, respectively. Mutation in codon S531L of the rpoB gene and codon S315T1 of katG genes were dominated in MDR-TB strains, respectively (P < 0.05. Conclusions: The GenoType® MTBDRplus assay is highly sensitive with short turnaround times and a rapid test for the detection of the most common mutations conferring resistance in MDR-TB strains that can readily be included in a routine laboratory workflow.

  17. The clinical study of serum PSA and fPSA assayed by CLIA in diagnosing prostate disease

    International Nuclear Information System (INIS)

    Xiong Jiang; Qian Xiaoyu; Ji Hong; Yang Su; Ding Ying; Zhu Ruisen; Chen Zhong

    2003-01-01

    The purpose of this study is to evaluate the clinical value of PSA (prostate specific antigen) and fPSA(free prostate specific antigen) in differentiating prostate disease. CLIA was used to quantitatively assay PSA, fPSA and fPSA/PSA in 30 cases of normal controls, 32 cases of prostate cancer patients and 76 cases of BPH patients. The result showed that if liminal value of PSA was set at 4 ng/mL, the diagnostic sensitivity and specificity of prostate cancer were 100% and 50.6% respectively. Meanwhile, if liminal value of fPSA/PSA set at 16% was added, the diagnostic sensitivity and specificity of prostate cancer were 100% and 85.3% respectively. It was concluded that the combining assay of PSA and fPSA could increase the diagnostic specificity of prostate cancer in a certain degree

  18. A micro-enzyme-linked immunosorbent assay (ELISA) and radioimmunosorbent technique (RIST) for the detection of immunity to clinical tetanus

    International Nuclear Information System (INIS)

    Layton, G.T.

    1980-01-01

    Enzyme-linked immunosorbent assay (ELISA), and radioimmunosorbent assay (RIST) techniques for the detection of tetanus toxin antibodies are described. Both methods proved to be highly sensitive, and allowed the measurement of 5 x 10 -3 units/ml tetanus antitoxin in human serum or plasma, sensitivity and reproducibility comparing well with other techniques previously described, and being superior to haemagglutination and latex agglutination tests. Results of the two methods correlated well, and reflected the immunization histories obtained. Micro ELISA and micro RIST would seem to be suitable for the detection of immunity, or non-immunity to clinical tetanus. (author)

  19. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    Science.gov (United States)

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  20. Analytical and clinical evaluation of the new Fujirebio Lumipulse®G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patients.

    Science.gov (United States)

    Cavalier, Etienne; Lukas, Pierre; Bekaert, Anne-Catherine; Peeters, Stéphanie; Le Goff, Caroline; Yayo, Eric; Delanaye, Pierre; Souberbielle, Jean-Claude

    2016-08-01

    In this study, we provide a short analytical evaluation of the new Fujirebio Lumipulse®G non-competitive immunoassay for 25(OH)D. Clinical performance was compared with three commercial competitive automated immunoassays against a Vitamin D Standardization Program (VDSP)-traceable liquid chromatography-tandem mass spectrometry (LC-MS/MS) in six different clinically relevant populations. Lumipulse®G 25(OH)D precision, measurement uncertainty, recovery, limit of quantification were assessed, as well as 25(OH)D2 and C3-epimer recovery. For method comparison, 250 serum samples obtained in healthy Caucasians and Africans, osteoporotic, hemodialyzed and intensive care patients and 3rd trimester pregnant women were analyzed by all methods. Correlation was studied using Passing-Bablok and Bland-Altman analysis. Concordance correlation coefficient (CCC) was calculated to evaluate agreement between immunoassays and the LC-MS/MS. The Lumipulse®G 25(OH)D assay presented interesting analytical features and showed excellent correlation to the LC-MS/MS results (y=1.00×-1.35 ng/mL), as obtained in healthy Caucasian individuals. In the other special populations, Lumipulse®G presented a concordance with LC-MS/MS which was generally higher than competitors, even if all methods significantly under-recovered 25(OH)D in hemodialyzed patients. Intra-assay CV ranged from 12.1% at 9.6 ng/mL to 2.1% at 103.7 ng/mL and inter-assay CV ranged from 16.2 to 3.7% at the same concentrations, respectively. Measurement uncertainty, with a probability of 95%, were respectively 33.1 and 7.6% at these concentrations. LOQ was found to be at 4.6 ng/mL. Mean (95% CI) 25(OH)D2 revovery was 77% (74-81) and no cross-reactivity was observed with C3-epimer. Fujirebio Lumipulse®G 25-OH Vitamin D Total assay is therefore considered suitable for assessment of vitamin D status in clinical routine.

  1. T2 Magnetic Resonance Assay: Overview of Available Data and Clinical Implications

    Directory of Open Access Journals (Sweden)

    Ioannis M. Zacharioudakis

    2018-04-01

    Full Text Available Invasive candidiasis is a common healthcare-associated infection with a high mortality rate that can exceed 60% in cases of septic shock. Blood culture performance is far from ideal, due to the long time to positivity and suppression by antifungal agents. The T2 Magnetic Resonance (T2MR assay is an FDA-approved qualitative molecular diagnostic method that can detect and speciate the 5 most common Candida spp.; namely, Candida albicans, Candida glabrata, Candida parapsilosis, Candida tropicalis, and Candida krusei, in approximately 5 h. In a multicenter clinical trial that included both a prospective and a contrived arm to represent the full range of clinically relevant concentrations of Candida spp., T2MR demonstrated a sensitivity and specificity of 91.1% and 98.1%, respectively. The utility of T2MR in candidemia depends on the prevalence of disease in each clinical setting. In intensive care units and other high-prevalence settings, the incorporation of T2MR in diagnostic algorithms is very appealing. T2MR is expected to allow timely initiation of antifungal therapy and help with anti-fungal stewardship. In low-prevalence settings, the positive predictive value of T2MR might not be enough to justify initiation of antifungal treatment in itself. The performance of T2MR has not been studied in cases of deep-seated candidiasis. Despite some promising evidence in published clinical trials, further studies are needed to determine the performance of T2MR in invasive candidiasis without candidemia. Overall, experience with T2MR in everyday clinical practice is evolving but, in the right setting, this technology is expected to provide “actionable information” for the management of patients evaluated for candidemia.

  2. Evaluation of a real-time PCR assay for rectal screening of OXA-48-producing Enterobacteriaceae in a general intensive care unit of an endemic hospital.

    Science.gov (United States)

    Fernández, J; Cunningham, S A; Fernández-Verdugo, A; Viña-Soria, L; Martín, L; Rodicio, M R; Escudero, D; Vazquez, F; Mandrekar, J N; Patel, R

    2017-07-01

    Carbapenemase-producing Enterobacteriaceae are increasing worldwide. Rectal screening for these bacteria can inform the management of infected and colonized patients, especially those admitted to intensive care units (ICUs). A laboratory developed, qualitative duplex real-time polymerase chain reaction assay for rapid detection of OXA-48-like and VIM producing Enterobacteriaceae, performed on rectal swabs, was designed and evaluated in an intensive care unit with endemic presence of OXA-48. During analytical assay validation, no cross-reactivity was observed and 100% sensitivity and specificity were obtained for both bla OXA-48-like and bla VIM in all spiked clinical samples. During the clinical part of the study, the global sensitivity and specificity of the real-time PCR assay for OXA-48 detection were 95.7% and 100% (P=0.1250), respectively, in comparison with culture; no VIM-producing Enterobacteriaceae were detected. Clinical features of patients in the ICU who were colonized or infected with OXA-48 producing Enterobacteriaceae, including outcome, were analyzed. Most had severe underlying conditions, and had risk factors for colonization with carbapenemase-producing Enterobacteriaceae before or during ICU admission, such as receiving previous antimicrobial therapy, prior healthcare exposure (including long-term care), chronic disease, immunosuppression and/or the presence of an intravascular catheter and/or mechanical ventilation device. The described real-time PCR assay is fast (~2-3hours, if DNA extraction is included), simple to perform and results are easy to interpret, features which make it applicable in the routine of clinical microbiology laboratories. Implementation in endemic hospitals could contribute to early detection of patients colonized by OXA-48 producing Enterobacteriaceae and prevention of their spread. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Development of a diagnostic real-time polymerase chain reaction assay for the detection of invasive Haemophilus influenzae in clinical samples.

    LENUS (Irish Health Repository)

    Meyler, Kenneth L

    2012-12-01

    Since the introduction of the Haemophilus influenzae serotype b vaccine, invasive H. influenzae disease has become dominated by nontypeable (NT) strains. Several widely used molecular diagnostic methods have been shown to lack sensitivity or specificity in the detection of some of these strains. Novel real-time assays targeting the fucK, licA, and ompP2 genes were developed and evaluated. The fucK assay detected all strains of H. influenzae tested (n = 116) and had an analytical sensitivity of 10 genome copies\\/polymerase chain reaction (PCR). This assay detected both serotype b and NT H. influenzae in 12 previously positive specimens (culture and\\/or bexA PCR) and also detected H. influenzae in a further 5 of 883 culture-negative blood and cerebrospinal fluid (CSF) samples. The fucK assay has excellent potential as a diagnostic test for detection of typeable and nontypeable strains of invasive H. influenzae in clinical samples of blood and CSF.

  4. Development of a diagnostic real-time polymerase chain reaction assay for the detection of invasive Haemophilus influenzae in clinical samples.

    Science.gov (United States)

    Meyler, Kenneth L; Meehan, Mary; Bennett, Desiree; Cunney, Robert; Cafferkey, Mary

    2012-12-01

    Since the introduction of the Haemophilus influenzae serotype b vaccine, invasive H. influenzae disease has become dominated by nontypeable (NT) strains. Several widely used molecular diagnostic methods have been shown to lack sensitivity or specificity in the detection of some of these strains. Novel real-time assays targeting the fucK, licA, and ompP2 genes were developed and evaluated. The fucK assay detected all strains of H. influenzae tested (n = 116) and had an analytical sensitivity of 10 genome copies/polymerase chain reaction (PCR). This assay detected both serotype b and NT H. influenzae in 12 previously positive specimens (culture and/or bexA PCR) and also detected H. influenzae in a further 5 of 883 culture-negative blood and cerebrospinal fluid (CSF) samples. The fucK assay has excellent potential as a diagnostic test for detection of typeable and nontypeable strains of invasive H. influenzae in clinical samples of blood and CSF. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Promoting early presentation of breast cancer in older women: sustained effect of an intervention to promote breast cancer awareness in routine clinical practice.

    Science.gov (United States)

    Dodd, Rachael H; Forster, Alice S; Sellars, Sarah; Patnick, Julietta; Ramirez, Amanda J; Forbes, Lindsay J L

    2017-06-05

    Older women have poorer survival from breast cancer, which may be at least partly due to poor breast cancer awareness leading to delayed presentation and more advanced stage at diagnosis. In a randomised trial, an intervention to promote early presentation of breast cancer in older women increased breast cancer awareness at 1 year compared with usual care (24 versus 4%). We examined its effectiveness in routine clinical practice. We piloted the intervention delivered by practising health professionals to women aged about 70 in four breast screening services. We measured the effect on breast cancer awareness at 1 year compared with comparison services, where women did not receive the intervention. At 1 year, 25% of women in pilot services were breast cancer aware compared with 4% in comparison services (p = 0.001). The components of breast cancer awareness were knowledge of breast cancer non-lump symptoms (pilot: 63% vs comparison: 82% at 1 year; OR = 2.56, 95% CI 1.92-3.42), knowledge of age related risk (pilot: 8% vs comparison: 36% at 1 year; OR = 5.56, 95% CI 4.0-7.74) and reported breast checking (pilot: 70% vs comparison: 78% at 1 year; OR = 1.49, 95% CI 1.13-1.96). The intervention may be as effective in routine clinical practice as in a randomised controlled trial. This intervention has the potential to reduce patient delay in the diagnosis of breast cancer in older women. The PEP trial was registered with the International Standard Registered Clinical/soCial sTudy Number (ISRCTN) as a clinical trial ( ISRCTN31994827 ) on 3rd October 2007.

  6. [Routine fluoroscopic investigations after primary bariatric surgery].

    Science.gov (United States)

    Gärtner, D; Ernst, A; Fedtke, K; Jenkner, J; Schöttler, A; Reimer, P; Blüher, M; Schön, M R

    2016-03-01

    Staple line and anastomotic leakages are life-threatening complications after bariatric surgery. Upper gastrointestinal (GI) tract X-ray examination with oral administration of a water-soluble contrast agent can be used to detect leaks. The aim of this study was to evaluate the impact of routine upper GI tract fluoroscopy after primary bariatric surgery. Between January 2009 and December 2014 a total of 658 bariatric interventions were carried out of which 442 were primary bariatric operations. Included in this single center study were 307 sleeve gastrectomies and 135 Roux-en-Y gastric bypasses. Up to December 2012 upper GI tract fluoroscopy was performed routinely between the first and third postoperative days and the detection of leakages was evaluated. In the investigation period 8 leakages (2.6 %) after sleeve gastrectomy, 1 anastomotic leakage in gastrojejunostomy and 1 in jejunojejunostomy after Roux-en-Y gastric bypass occurred. All patients developed clinical symptoms, such as abdominal pain, tachycardia or fever. In one case the leakage was detected by upper GI fluoroscopy and in nine cases radiological findings were unremarkable. No leakages were detected in asymptomatic patients. Routine upper GI fluoroscopy is not recommended for uneventful postoperative courses after primary bariatric surgery.

  7. An Easy Method to Eliminate the Effect of Lupus Anticoagulants in the Coagulation Factor Assay.

    Science.gov (United States)

    Tang, Ning; Yin, Shiyu

    2016-07-01

    To build and evaluate intrinsic coagulation factor assays which can eliminate the effect of lupus anticoagulants (LAC). Commercial silica clotting time confirmatory (SCT-C) reagent containing sufficient synthetic phospholipid and routine activated partial thromboplastin time (APTT) reagent were each used for one-stage detection of FVIII, FIX, and FXI activities, in samples with or without LAC, and the results were compared. For samples without LAC, consistent results of FVIII, FIX, and FXI using both SCT-C reagent and APTT reagent were obtained. For samples with LAC, the assays with SCT-C reagent not only could eliminate the effect of strong lupus anticoagulants but also needed fewer dilutions than that with routine APTT reagent. The intrinsic factor detections by SCT-C reagent are credible and convenient to be used for samples with LAC.

  8. How do youth with experience of violence victimization and/or risk drinking perceive routine inquiry about violence and alcohol consumption in Swedish youth clinics? A qualitative study.

    Science.gov (United States)

    Palm, Anna; Danielsson, Ingela; Högberg, Ulf; Norbergh, Karl-Gustav

    2017-10-01

    To explore perceptions and experiences among youth who underwent structured questions about violence victimization and alcohol consumption when visiting Swedish youth clinics. This study is part of a larger research project examining the effect of including routine inquiry about violence victimization and alcohol consumption for youth visiting youth clinics. Fifteen youth with experiences of victimization and/or risk drinking (AUDIT-C≥5) were interviewed. Content analysis was used. The findings were grouped into three main categories: The first; "Disclosure - talking about violence" reflected the participants' experiences of being asked about victimization. Participants were in favor of routine inquiry about violence victimization, even when questions caused distress. The questions helped participants reflect on prior victimization and process what had happened to them. The second; "Influence on the life situation" demonstrated that many of the participants still were effected by prior victimization, but also how talking about violence sometimes led to the possibility of initiating change such as leaving a destructive relationship or starting therapy. In the third; "One's own alcohol consumption in black and white" participants considered it natural to be asked about alcohol consumption. However, most participants did not consider their drinking problematic, even when told they exceeded guidelines. They viewed risk drinking in terms of immediate consequences rather than in quantity or frequency of alcohol intake. Routine inquiry about violence victimization and risk drinking at youth clinics was well received. Questions about violence helped participants to interpret and process prior victimization and sometimes initiated change. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Is daily routine important for sleep? An investigation of social rhythms in a clinical insomnia population.

    Science.gov (United States)

    Moss, Taryn G; Carney, Colleen E; Haynes, Patricia; Harris, Andrea L

    2015-02-01

    Social rhythms, also known as daily routines (e.g. exercise, of school or work, recreation, social activities), have been identified as potential time cues to help to regulate the biological clock. Past research has shown links between regularity and healthy sleep. This study examined the regularity and frequency of daytime activities in a clinical insomnia population and a good sleeper comparison group. Participants (N = 69) prospectively monitored their sleep and daily activities for a 2-week period. Although participants with insomnia and good sleepers had similar levels of activity, relative to good sleepers, those with insomnia were less regular in their activities. Findings from this study add to the growing number of studies that highlight the relative importance of the regularity of daytime activities on sleep. Accordingly, future research should test treatment components that focus on regulating daytime activities, which would likely improve treatment outcomes.

  10. External Agents' Effect on Routine Dynamics:Lack of Compliance Resulting in Routine Breakdown

    OpenAIRE

    Busse Hansen, Nicolai

    2014-01-01

    Prior investigations on organizational routines have called for re- search to enlighten our understanding of how social actors establish and main- tain of routines as well as the causes of their disruption. The present paper con- tributes to this call by conducting systematic microethnographic analyses of naturally occurring interactional routine data in the form of recordings of job interviews in an international oil contractor company. The term interactional routine is used to describe recu...

  11. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    Science.gov (United States)

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  12. Sensitivity and specificity of four assays to detect human T-lymphotropic virus type I or type I/II antibodies

    NARCIS (Netherlands)

    Vrielink, H.; Reesink, H. W.; Zaaijer, H. L.; van der Poel, C. L.; Cuypers, H. T.; Lelie, P. N.

    1996-01-01

    BACKGROUND: Assays that detect human T-lymphotropic virus type I and type II antibody (HTLV-I/II) are widely used in the routine screening of blood donors. STUDY DESIGN AND METHODS: Four commercially available anti-HTLV-I (Fujirebio and Organon Teknika) or -HTLV-I/II assays (Murex and Ortho) were

  13. Minimal residual HIV viremia: verification of the Abbott Real-Time HIV-1 assay sensitivity

    Directory of Open Access Journals (Sweden)

    Alessandra Amendola

    2010-06-01

    Full Text Available Introduction: In the HIV-1 infection, the increase in number of CD4 T lymphocytes and the viral load decline are the main indicators of the effectiveness of antiretroviral therapy. On average, 85% of patients receiving effective treatment has a persistent suppression of plasma viral load below the detection limit (<50 copies/mL of clinically used viral load assays, regardless of treatment regimen in use. It is known, however, that, even when viremia is reduced below the sensitivity limit of current diagnostic assays, the virus persists in “reservoirs” and traces of free virions can be detected in plasma.There is a considerable interest to investigate the clinical significance of residual viremia. Advances in molecular diagnostics allows nowadays to couple a wide dynamic range to a high sensitivity.The Abbott Real-time HIV-1 test is linear from 40 to 107 copies/mL and provides, below 40 copies/mL, additional information such as “<40cp/mL, target detected” or “target not detected”. The HIV-1 detection is verified by the max-Ratio algorithm software.We assessed the test sensitivity when the qualitative response is considered as well. Methods: A ‘probit’ analysis was performed using dilutions of the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC code: 99/634, defined in IU/mL and different from that used by the manufacturer (VQA,Virology Quality Assurance Laboratory of the AIDS Clinical Trial Group for standardization and definition of performances.The sample input volume (0.6 mL was the same used in clinical routine. A total of 196 replicates at concentrations decreasing from 120 to 5 copies/mL, in three different sessions, have been tested.The ‘probit’ analysis (binomial dose-response model, 95% “hit-rate” has been carried out on the SAS 9.1.3 software package. Results: The sensitivity of the “<40cp/mL, target detected” response was equal to 28,76 copies/mL, with 95% confidence limits between 22,19 and 52,27 copies

  14. Glucuronoyl Esterase Screening and Characterization Assays Utilizing Commercially Available Benzyl Glucuronic Acid Ester

    Directory of Open Access Journals (Sweden)

    Hampus Sunner

    2015-09-01

    Full Text Available Research on glucuronoyl esterases (GEs has been hampered by the lack of enzyme assays based on easily obtainable substrates. While benzyl d-glucuronic acid ester (BnGlcA is a commercially available substrate that can be used for GE assays, several considerations regarding substrate instability, limited solubility and low apparent affinities should be made. In this work we discuss the factors that are important when using BnGlcA for assaying GE activity and show how these can be applied when designing BnGlcA-based GE assays for different applications: a thin-layer chromatography assay for qualitative activity detection, a coupled-enzyme spectrophotometric assay that can be used for high-throughput screening or general activity determinations and a HPLC-based detection method allowing kinetic determinations. The three-level experimental procedure not merely facilitates routine, fast and simple biochemical characterizations but it can also give rise to the discovery of different GEs through an extensive screening of heterologous Genomic and Metagenomic expression libraries.

  15. Acute HIV infection (AHI) in a specialized clinical setting: case-finding, description of virological, epidemiological and clinical characteristics.

    Science.gov (United States)

    Ammassari, Adriana; Abbate, Isabella; Orchi, Nicoletta; Pinnetti, Carmela; Rozera, Gabriella; Libertone, Raffaella; Pierro, Paola; Martini, Federico; Puro, Vincenzo; Girardi, Enrico; Antinori, Andrea; Capobianchi, Maria Rosaria

    2014-01-01

    Diagnosis of HIV infection during early stages is mandatory to catch up with the challenge of limiting HIV viral replication and reservoirs formation, as well as decreasing HIV transmissions by immediate cART initiation. Aims were to describe (a) virological characteristics of AHI identified, (b) epidemiological and clinical factors associated with being diagnosed with AHI. Cross-sectional, retrospective study. All individuals diagnosed with AHI according to Fiebig's staging between Jan 2013 and Mar 2014 at the INMI "L. Spallanzani" were included. Serum samples reactive to a fourth generation HIV-1/2 assay (Architect HIV Ag/Ab Combo, Abbott) were retested with another fourth generation assay (VIDAS DUO HIV Ultra, Biomérieux) and underwent confirmation with HIV-1 WB (New Lav I Bio-Rad) and/or with Geenius confirmatory assay (Bio-Rad). WHO criteria (two env products reactivity) were used to establish positivity of confirmatory assays. In case of clinically suspected AHI, HIV-1 RNA (Real time, Abbott) and p24 assay (VIDAS HIV P24 Bio-Rad) were also performed. Avidity test was carried out, on confirmed positive samples lacking p31 reactivity, to discriminate between recent (true Fiebig V phase) and late infections; to avoid possible misclassifications, clinical data were also used. Demographic, epidemiological, clinical and laboratory data are routinely, and anonymously recorded in the SENDIH and SIREA studies. During the study period, we observed 483 newly HIV diagnosed individuals, of whom 40 were identified as AHI (8.3%). Fiebig classification showed: 7 stage II/III, 13 stage IV, 20 stage V. Demographic, epidemiological, and clinical characteristics of patients are shown in the Table. Overall, the study population had a median S/Co ratio at fourth generation EIA (Architect) of 49.50 (IQR, 23.54-98.05): values were significantly lower in Fiebig II-IV than in Fiebig V (38.68 [IQR, 20.08-54.84] vs 75.72 [IQR, 42.66-249.80], p=0.01). Overall, median HIV-1 RNA was 5

  16. Comparison of mRNA Splicing Assay Protocols across Multiple Laboratories

    DEFF Research Database (Denmark)

    Whiley, Phillip J; de la Hoya, Miguel; Thomassen, Mads

    2014-01-01

    Accurate evaluation of unclassified sequence variants in cancer predisposition genes is essential for clinical management and depends on a multifactorial analysis of clinical, genetic, pathologic, and bioinformatic variables and assays of transcript length and abundance. The integrity of assay data...

  17. Dual germanium detector system for the routine assay of low level transuranics in soil

    International Nuclear Information System (INIS)

    Crowell, J.M.

    1980-01-01

    As an outgrowth of previous on soil radioassay, we have developed an automated assay system for determining the transuranic radionuclide content of soils, with particular interest in Pu. The system utilizes two commercial planar intrinsic germanium detectors in opposition. The large area of the detectors (2100 mm 2 ) and the thinness of the detector crystals (7 mm) permit sensitive analysis of the L x ray emission region of the transuranics (13 to 21 keV). With counting times of 5 hours, we obtain detection limits of 241 Am

  18. Cyclophosphamide administration routine in autoimmune rheumatic diseases: a review

    Directory of Open Access Journals (Sweden)

    Kaian Amorim Teles

    Full Text Available Abstract Cyclophosphamide is an alkylating agent widely used for the treatment of malignant neoplasia and which can be used in the treatment of multiple rheumatic diseases. Medication administration errors may lead to its reduced efficacy or increased drug toxicity. Many errors occur in the administration of injectable drugs. The present study aimed at structuring a routine for cyclophosphamide use, as well as creating a document with pharmacotherapeutic guidelines for the patient. The routine is schematized in three phases: pre-chemotherapy, administration of cyclophosphamide, and post-chemotherapy, taking into account the drugs to be administered before and after cyclophosphamide in order to prevent adverse effects, including nausea and hemorrhagic cystitis. Adverse reactions can alter laboratory tests; thus, this routine included clinical management for changes in white blood cells, platelets, neutrophils, and sodium, including cyclophosphamide dose adjustment in the case of kidney disease. Cyclophosphamide is responsible for other rare - but serious - side effects, for instance, hepatotoxicity, severe hyponatremia and heart failure. Other adverse reactions include hair loss, amenorrhea and menopause. In this routine, we also entered guidelines to post-chemotherapy patients. The compatibility of injectable drugs with the vehicle used has been described, as well as stability and infusion times. The routine aimed at the rational use of cyclophosphamide, with prevention of adverse events and relapse episodes, factors that may burden the health care system.

  19. Pitfalls in the routine diagnosis of Staphylococcus aureus | Bello ...

    African Journals Online (AJOL)

    Two hundred isolates of Presumed Staphylococcus aureus from routine clinical specimens, collected from two government hospitals in Abha, Saudi Arabia, had their identity verified. We used the tube coagulase test as our gold standard. Twenty (10%) of the isolates were mis-identified. Reliance by the two laboratories on ...

  20. Evaluation of a single-tube fluorogenic RT-PCR assay for detection of bovine respiratory syncytial virus in clinical samples

    DEFF Research Database (Denmark)

    Hakhverdyan, Mikhayil; Hägglund, Sara; Larsen, Lars Erik

    2005-01-01

    understanding of the virus. In this study, a BRSV fluorogenic reverse transcription PCR (fRT-PCR) assay, based on TaqMan principle, was developed and evaluated on a large number of clinical samples, representing various cases of natural and experimental BRSV infections. By using a single-step closed-tube format......, the turn-around time was shortened drastically and results were obtained with minimal risk for cross-contamination. According to comparative analyses, the detection limit of the fRT-PCR was on the same level as that of a nested PCR and the sensitivity relatively higher than that of a conventional PCR......, antigen ELISA (Ag-ELISA) and virus isolation (VI). Interspersed negative control samples, samples from healthy animals and eight symptomatically or genetically related viruses were all negative, confirming a high specificity of the assay. Taken together, the data indicated that the fRT-PCR assay can...

  1. Is routine measurement of TSH in hospitalized patients necessary?

    Directory of Open Access Journals (Sweden)

    Amir Bashkin

    2018-04-01

    Full Text Available TSH routine testing in hospitalized patients has low efficacy, but may be beneficial in a selected subgroup of patients. Our aim was to evaluate the efficacy of routine thyroid function tests among patients admitted to internal medicine departments. It is a retrospective study. A randomly selected cohort of hospitalized patients with abnormal thyroid-stimulating hormone (TSH blood tests drawn as part of admission protocol. Patient data were collected from the electronic medical files and analyzed for its efficacy. TSH as a screening test was proven unnecessary in 75% (174 of the study population. Leading causes were non-thyroidal illness syndrome, drugs affecting the test results and subclinical disorders. TSH testing was found to be clinically helpful in only 9 patients; however, all of them had other clinical need for TSH testing. We found a clinically abnormal TSH in 20 patients, hypothyroidism in 11 patients and thyrotoxicosis in 9 patients. Low efficacy ascribed to TSH screening test by this study correlates with recent recommendations that indicate TSH screening in admitted patients only with accompanying clinical suspicion. Most probably, the majority of patients found by screening to have thyrotoxicosis have non-thyroidal illness or drug effects so the threshold for FT4 to diagnose overt thyrotoxicosis should be higher than that in ambulatory patients. In elderly patients, clinically relevant TSH disturbances are more frequent and are harder to diagnose, therefore, TSH screening in this group of patients might be beneficial.

  2. Evaluation of the Roche LightMix Gastro parasites multiplex PCR assay detecting Giardia duodenalis, Entamoeba histolytica, cryptosporidia, Dientamoeba fragilis, and Blastocystis hominis.

    Science.gov (United States)

    Friesen, J; Fuhrmann, J; Kietzmann, H; Tannich, E; Müller, M; Ignatius, R

    2018-03-23

    Multiplex PCR assays offer highly sensitive and specific tools for the detection of enteric pathogens. This prospective study aimed at comparing the novel Roche LightMix Modular Assay Gastro Parasites (LMAGP) detecting Giardia duodenalis, Entamoeba histolytica, Cryptosporidium spp., Blastocystishominis, and Dientamoebafragilis with routine laboratory procedures. Stool specimens (n = 1062 from 1009 patients) were consecutively examined by LMAGP, R-Biopharm Ridascreen enzyme immunoassays (EIAs) detecting G. duodenalis or E. histolytica/dispar, and microscopy of wet mounts. Discrepant results were analysed by in-house PCR. D. fragilis or B. hominis were detected by LMAGP in 131 (14.4%) and 179 (19.9%; 16 samples positive by microscopy; p PCR). G. duodenalis was detected by LMAGP, EIA, or microscopy in 20, 16, or 9 of 1039 stool samples, respectively; all four samples missed by EIA were confirmed by in-house PCR. In total, 938 stool samples were analysed for E. histolytica/dispar. Nine of ten EIA-positive samples were negative by LMAGP but positive by in-house PCR for E. dispar. One E. histolytica infection (positive by both LMAGP and in-house PCR) was missed by EIA and microscopy. Parasites only detected by microscopy included Enterobius vermicularis eggs (n = 3) and apathogenic amoebae (n = 27). The data call for routine use of multiplex PCR assays for the detection of enteric protozoan parasites in laboratory diagnostics. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. The embeddedness of selfish Routines

    DEFF Research Database (Denmark)

    Andersen, Poul Houman

    2001-01-01

    Routines have traditionally been seen as an organisational feature. However, like genes, routines may be carriers and initiators of organisations as well......Routines have traditionally been seen as an organisational feature. However, like genes, routines may be carriers and initiators of organisations as well...

  4. Clonality analysis of lymphoid proliferations using the BIOMED-2 clonality assays: a single institution experience

    Science.gov (United States)

    Kokovic, Ira; Novakovic, Barbara Jezersek; Cerkovnik, Petra; Novakovic, Srdjan

    2014-01-01

    Background Clonality determination in patients with lymphoproliferative disorders can improve the final diagnosis. The aim of our study was to evaluate the applicative value of standardized BIOMED-2 gene clonality assay protocols for the analysis of clonality of lymphocytes in a group of different lymphoid proliferations. Materials and methods. With this purpose, 121 specimens from 91 patients with suspected lymphoproliferations submitted for routine diagnostics from January to December 2011 were retrospectively analyzed. According to the final diagnosis, our series comprised 32 cases of B-cell lymphomas, 38 cases of non-Hodgkin’s T-cell lymphomas and 51 cases of reactive lymphoid proliferations. Clonality testing was performed using the BIOMED-2 clonality assays. Results The determined sensitivity of the TCR assay was 91.9%, while the sensitivity of the IGH assay was 74.2%. The determined specificity of the IGH assay was 73.3% in the group of lymphomas and 87.2% in the group of reactive lesions. The determined specificity of the TCR assay was 62.5% in the group of lymphomas and 54.3% in the group of reactive lesions. Conclusions In the present study, we confirmed the utility of standardized BIOMED-2 clonality assays for the detection of clonality in a routine diagnostical setting of non-Hodgkin’s lymphomas. Reactions for the detection of the complete IGH rearrangements and reactions for the detection of the TCR rearrangements are a good choice for clonality testing of a wide range of lymphoid proliferations and specimen types while the reactions for the detection of incomplete IGH rearrangements have not shown any additional diagnostic value. PMID:24991205

  5. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    Science.gov (United States)

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients 10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  6. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    Science.gov (United States)

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  7. Detection of high-risk subtypes of human papillomavirus in cervical swabs: routine use of the Digene Hybrid Capture assay and polymerase chain reaction analysis.

    LENUS (Irish Health Repository)

    Brennan, M M

    2012-02-03

    Human papillomaviruses (HPVs) are major causative agents in the pathogenesis of cervical cancer, and more than twenty types are associated with its development. With the introduction of liquid-based preparation systems, it is envisaged that large-scale HPV testing will be established in the near future. Preliminary studies demonstrate the accessibility of these samples for DNA testing using both the Digene Hybrid Capture assay (DHCA) and polymerase chain reaction (PCR) techniques. This study aims to assess the validity and sensitivity of the DHCA system to detect high-risk HPV DNA, using two sets of HPV consensus primers (Gp5+\\/Gp6+ and MY09\\/MY11) in tandem with routine assessment of cervical smear and biopsy samples. Results indicate that the combination of DHCA and PCR detects more high-grade lesions than does the DHCA alone. DHCA-negative cases were categorised by subsequent PCR amplification into low-grade HPV-negative (12\\/16) cervical lesions and high-grade HPV-positive (7\\/9) cervical lesions. Gp5+\\/Gp6+ primers were less sensitive in detecting HPV-positive samples than was the MY09\\/MY11 primer set. These results support the use of high-risk HPV testing by DHCA, with subsequent analysis of DHCA-negative samples by PCR using the MY09\\/MY11 primers.

  8. The Abbott RealTime High Risk HPV test is a clinically validated human papillomavirus assay for triage in the referral population and use in primary cervical cancer screening in women 30 years and older: a review of validation studies.

    Science.gov (United States)

    Poljak, Mario; Oštrbenk, Anja

    2013-01-01

    Human papillomavirus (HPV) testing has become an essential part of current clinical practice in the management of cervical cancer and precancerous lesions. We reviewed the most important validation studies of a next-generation real-time polymerase chain reaction-based assay, the RealTime High Risk HPV test (RealTime)(Abbott Molecular, Des Plaines, IL, USA), for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older published in peer-reviewed journals from 2009 to 2013. RealTime is designed to detect 14 high-risk HPV genotypes with concurrent distinction of HPV-16 and HPV-18 from 12 other HPV genotypes. The test was launched on the European market in January 2009 and is currently used in many laboratories worldwide for routine detection of HPV. We concisely reviewed validation studies of a next-generation real-time polymerase chain reaction (PCR)-based assay: the Abbott RealTime High Risk HPV test. Eight validation studies of RealTime in referral settings showed its consistently high absolute clinical sensitivity for both CIN2+ (range 88.3-100%) and CIN3+ (range 93.0-100%), as well as comparative clinical sensitivity relative to the currently most widely used HPV test: the Qiagen/Digene Hybrid Capture 2 HPV DNA Test (HC2). Due to the significantly different composition of the referral populations, RealTime absolute clinical specificity for CIN2+ and CIN3+ varied greatly across studies, but was comparable relative to HC2. Four validation studies of RealTime performance in cervical cancer screening settings showed its consistently high absolute clinical sensitivity for both CIN2+ and CIN3+, as well as comparative clinical sensitivity and specificity relative to HC2 and GP5+/6+ PCR. RealTime has been extensively evaluated in the last 4 years. RealTime can be considered clinically validated for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older.

  9. Development of a routine analysis of 4-mercapto-4-methylpentan-2-one in wine by stable isotope dilution assay and mass tandem spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dagan, Laurent; Reillon, Florence; Roland, Aurélie; Schneider, Rémi, E-mail: remi@nyseos.fr

    2014-04-01

    Highlights: • We proposed a routine method to analyze the 4-methyl-4-mercaptopentan-2-one in wine. • We developed the first method with sensitivity below the 4MMP perception threshold. • We obtained an accurate method by using the stable isotope dilution assay approach. Abstract: The 4-mercapto-4-methylpentan-2-one (4MMP) is a key aroma compound in wines, especially in Sauvignon Blanc ones. Its accurate quantification is quite difficult due to its traces levels and its reactivity in wine conferred by the thiol function. In this paper, we proposed a new method for its quantification in wine without any sample preparation, based on automated derivatization procedure by methoximation and SIDA–SPME–GC–MS/MS analysis. The derivatization procedure was adapted from a previously published method in order to decrease the amount of reagents and the volume of wine (only 3 mL are required). The use of SPME and the detection conditions have also been optimized to reach the best sensitivity as possible. The method was then validated according to the International Organization of Vine and Wine recommendations and exhibited excellent performances. Indeed, this method allowed us to quantify the 4MMP in wine at traces levels (LOD = 0.19 ng L₅⁻¹) with reproducible results (RSD < 15%) and a very good accuracy (recovery = 102%)

  10. Development of a routine analysis of 4-mercapto-4-methylpentan-2-one in wine by stable isotope dilution assay and mass tandem spectrometry

    International Nuclear Information System (INIS)

    Dagan, Laurent; Reillon, Florence; Roland, Aurélie; Schneider, Rémi

    2014-01-01

    Highlights: • We proposed a routine method to analyze the 4-methyl-4-mercaptopentan-2-one in wine. • We developed the first method with sensitivity below the 4MMP perception threshold. • We obtained an accurate method by using the stable isotope dilution assay approach. - Abstract: The 4-mercapto-4-methylpentan-2-one (4MMP) is a key aroma compound in wines, especially in Sauvignon Blanc ones. Its accurate quantification is quite difficult due to its traces levels and its reactivity in wine conferred by the thiol function. In this paper, we proposed a new method for its quantification in wine without any sample preparation, based on automated derivatization procedure by methoximation and SIDA–SPME–GC–MS/MS analysis. The derivatization procedure was adapted from a previously published method in order to decrease the amount of reagents and the volume of wine (only 3 mL are required). The use of SPME and the detection conditions have also been optimized to reach the best sensitivity as possible. The method was then validated according to the International Organization of Vine and Wine recommendations and exhibited excellent performances. Indeed, this method allowed us to quantify the 4MMP in wine at traces levels (LOD = 0.19 ng L −1 ) with reproducible results (RSD < 15%) and a very good accuracy (recovery = 102%)

  11. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  12. Microbiological assay for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S

    2005-04-01

    Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.

  13. Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice.

    Science.gov (United States)

    Akerström, Finn; Narváez, Irene; Puchol, Alberto; Pachón, Marta; Martín-Sierra, Cristina; Rodríguez-Mañero, Moisés; Rodríguez-Padial, Luis; Arias, Miguel A

    2017-09-23

    Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  14. The birth and routinization of IVF in China

    DEFF Research Database (Denmark)

    Wahlberg, Ayo

    2016-01-01

    How can it be that China today is home to some of the world’s largest IVF clinics, carrying out as many as 30,000 cycles annually? In this article, I address how IVF was developed in China during the early 1980s only to be routinized during the exact same period that one of the world’s most compr...

  15. The art and science of using routine outcome measurement in mental health benchmarking.

    Science.gov (United States)

    McKay, Roderick; Coombs, Tim; Duerden, David

    2014-02-01

    To report and critique the application of routine outcome measurement data when benchmarking Australian mental health services. The experience of the authors as participants and facilitators of benchmarking activities is augmented by a review of the literature regarding mental health benchmarking in Australia. Although the published literature is limited, in practice, routine outcome measures, in particular the Health of the National Outcomes Scales (HoNOS) family of measures, are used in a variety of benchmarking activities. Use in exploring similarities and differences in consumers between services and the outcomes of care are illustrated. This requires the rigour of science in data management and interpretation, supplemented by the art that comes from clinical experience, a desire to reflect on clinical practice and the flexibility to use incomplete data to explore clinical practice. Routine outcome measurement data can be used in a variety of ways to support mental health benchmarking. With the increasing sophistication of information development in mental health, the opportunity to become involved in benchmarking will continue to increase. The techniques used during benchmarking and the insights gathered may prove useful to support reflection on practice by psychiatrists and other senior mental health clinicians.

  16. Biomarkers in routine diagnosis of pleural effusions

    Directory of Open Access Journals (Sweden)

    Tiva Nemanič

    2018-03-01

    Full Text Available Background: Pleural fluid biochemical analysis is the first step in pleural effusion (PE diagnostics. Our purpose was to analyse the utility of the biomarkers used at our clinic in the routine diagnosis of PE. Methods: We retrospectively reviewed the PE levels of proteins, lactate dehydrogenase (LDH, alpha amylase (AA, pH and glucose in 433 patients who were treated at the University Clinic Golnik in a one-year period and compared these values with the final identified aetiology of the effusions. Results: The majority of the effusions were determined to be a consequence of malignancy (n = 154 or infection (n = 108. In 94 cases the aetiology of the effusions was heart failure and in 54 cases other diseases, while 23 effusions remained aetiologically undetermined. Considering Light’s criteria, the vast majority of the effusions were correctly classified as exudates or transudates (97.1 %. Comparing paramalignant and malignant effusions, we detected significantly lower values of pleural fluid LDH (p < 0.0005 and proteins (p < 0.0005, and higher pH (p < 0.0005 values in the paramalignant effusions. Conclusion: We have found that pleural LDH and proteins are the most helpful biochemical parameters in our routine diagnosis of pleural effusions and helped us to correctly narrow the aetiological spectrum. Furthermore, significantly higher pleural LDH and protein values and a pH below 7.32 additionally facilitated distinguishing between malignant and paramalignant effusions. Parameters such as glucose and AA are useful in selected cases and have a limited role in routine diagnostics.

  17. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  18. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  19. Clinical and para-clinical tests in the routine examination of headache patients

    DEFF Research Database (Denmark)

    Friberg, L; Sandrini, G; Jänig, W

    2000-01-01

    Para-clinical examinations in the diagnosis and treatment control of headache patients vary considerably between clinics and headache centers. Among the neurological societies in Europe there has been a consensus that some common procedures and recommendations should be created. In the Fall of 19...

  20. Clinical experience with routine diode dosimetry for electron beam radiotherapy

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Fontenla, Doracy P.; Vikram, Bhadrasain

    2000-01-01

    Purpose: Electron beam radiotherapy is frequently administered based on clinical setups without formal treatment planning. We felt, therefore, that it was important to monitor electron beam treatments by in vivo dosimetry to prevent errors in treatment delivery. In this study, we present our clinical experience with patient dose verification using electron diodes and quantitatively assess the dose perturbations caused by the diodes during electron beam radiotherapy. Methods and Materials: A commercial diode dosimeter was used for the in vivo dose measurements. During patient dosimetry, the patients were set up as usual by the therapists. Before treatment, a diode was placed on the patient's skin surface and secured with hypoallergenic tape. The patient was then treated and the diode response registered and stored in the patient radiotherapy system database via our in-house software. A customized patient in vivo dosimetry report showing patient details, expected and measured dose, and percent difference was then generated and printed for analysis and record keeping. We studied the perturbation of electron beams by diodes using film dosimetry. Beam profiles at the 90% prescription isodose depths were obtained with and without the diode on the beam central axis, for 6-20 MeV electron beams and applicator/insert sizes ranging from a 3-cm diameter circular field to a 25 x 25 cm open field. Results: In vivo dose measurements on 360 patients resulted in the following ranges of deviations from the expected dose at the various anatomic sites: Breast (222 patients) -20.3 to +23.5% (median deviation 0%); Head and Neck (63 patients) -21.5 to +14.8% (median -0.7%); Other sites (75 patients) -17.6 to +18.8% (median +0.5%). Routine diode dosimetry during the first treatment on 360 patients (460 treatment sites) resulted in 11.5% of the measurements outside our acceptable ±6% dose deviation window. Only 3.7% of the total measurements were outside ±10% dose deviation. Detailed

  1. Synthesis of [{sup 123}I]IBZM: a reliable procedure for routine clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Zea-Ponce, Yolanda E-mail: yolanda@neuron.cpmc.columbia.edu; Laruelle, Marc

    1999-08-01

    The single photon emission computed tomography (SPECT) D{sub 2}/D{sub 3} receptor radiotracer [{sup 123}I]IBZM, is prepared by electrophilic radioiodination of the precursor BZM with high-purity sodium [{sup 123}I]iodide in the presence of diluted peracetic acid. However, in our hands, the most commonly used procedure for this radiosynthesis produced variable and inconsistent labeling yields, to such extent that it became inappropriate for routine clinical studies. Our goal was to modify the labeling procedure, to obtain consistently better labeling and radiochemical yields. The best conditions found for the radioiodination were as follows: 50 {mu}g precursor in 50 {mu}L EtOH mixed with buffer pH 2; Na[{sup 123}I]I in 0.1 M NaOH (<180 {mu}L), 50 {mu}L peracetic acid diluted solution, heating at 65 deg. C for 14 min. Purification was achieved by solid phase extraction (SPE) and reverse-phase high performance liquid chromatography (HPLC). Under these conditions, labeling yield average was 76{+-}4% (n=31); radiochemical yield was 69{+-}4% and radiochemical purity was 98{+-}1%. With larger volumes of the Na[{sup 123}I]I solution the yields were consistent but lower. For example, for volumes between 417 and 523 {mu}L the labeling yield was 61{+-}5% (n=21), radiochemical yield was 56{+-} 5% and radiochemical purity was 98{+-}1%.

  2. Generating Novelty Through Interdependent Routines: A Process Model of Routine Work

    NARCIS (Netherlands)

    Deken, F.; Carlile, P.R.; Berends, H.; Lauche, K.

    2016-01-01

    We investigate how multiple actors accomplish interdependent routine performances directed at novel intended outcomes and how this affects routine dynamics over time. We report findings from a longitudinal ethnographic study in an automotive company where actors developed a new business model around

  3. Italian Association of Clinical Endocrinologists (AME and Italian Chapter of the American Association of Clinical Endocrinologists (AACE Position Statement: Clinical Management of Vitamin D Deficiency in Adults

    Directory of Open Access Journals (Sweden)

    Roberto Cesareo

    2018-04-01

    Full Text Available Vitamin D deficiency is very common and prescriptions of both assay and supplementation are increasing more and more. Health expenditure is exponentially increasing, thus it is timely and appropriate to establish rules. The Italian Association of Clinical Endocrinologists appointed a task force to review literature about vitamin D deficiency in adults. Four topics were identified as worthy for the practicing clinicians. For each topic recommendations based on scientific evidence and clinical practice were issued according to the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE System. (1 What cut-off defines vitamin D deficiency: even though 20 ng/mL (50 nmol/L can be considered appropriate in the general population, we recommend to maintain levels above 30 ng/mL (75 nmol/L in categories at risk. (2 Whom, when, and how to perform screening for vitamin D deficiency: categories at risk (patients with bone, liver, kidney diseases, obesity, malabsorption, during pregnancy and lactation, some elderly but not healthy people should be screened by the 25-hydroxy-vitamin D assay. (3 Whom and how to treat vitamin D deficiency: beyond healthy lifestyle (mostly sun exposure, we recommend oral vitamin D (vitamin D2 or vitamin D3 supplementation in patients treated with bone active drugs and in those with demonstrated deficiency. Dosages, molecules and modalities of administration can be profitably individually tailored. (4 How to monitor the efficacy of treatment with vitamin D: no routine monitoring is suggested during vitamin D treatment due to its large therapeutic index. In particular conditions, 25-hydroxy-vitamin D can be assayed after at least a 6-month treatment. We are confident that this document will help practicing clinicians in their daily clinical practice.

  4. Multiplexed Molecular Assays for Rapid Rule-Out of Foot-and-Mouth Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lenhoff, R; Naraghi-Arani, P; Thissen, J; Olivas, J; Carillo, C; Chinn, C; Rasmussen, M; Messenger, S; Suer, L; Smith, S M; Tammero, L; Vitalis, E; Slezak, T R; Hullinger, P J; Hindson, B J; Hietala, S; Crossley, B; Mcbride, M

    2007-06-26

    A nucleic acid-based multiplexed assay was developed that combines detection of foot-and-mouth disease virus (FMDV) with rule-out assays for two other foreign animal diseases and four domestic animal diseases that cause vesicular or ulcerative lesions indistinguishable from FMDV infection in cattle, sheep and swine. The FMDV 'look-alike' diagnostic assay panel contains five PCR and twelve reverse transcriptase PCR (RT-PCR) signatures for a total of seventeen simultaneous PCR amplifications for seven diseases plus incorporating four internal assay controls. It was developed and optimized to amplify both DNA and RNA viruses simultaneously in a single tube and employs Luminex{trademark} liquid array technology. Assay development including selection of appropriate controls, a comparison of signature performance in single and multiplex testing against target nucleic acids, as well of limits of detection for each of the individual signatures is presented. While this assay is a prototype and by no means a comprehensive test for FMDV 'look-alike' viruses, an assay of this type is envisioned to have benefit to a laboratory network in routine surveillance and possibly for post-outbreak proof of freedom from foot-and-mouth disease.

  5. A method for simultaneous quantification of phospholipid species by routine 31P NMR

    DEFF Research Database (Denmark)

    Brinkmann-Trettenes, Ulla; Stein, Paul C.; Klösgen, Beate Maria

    2012-01-01

    We report a 31P NMR assay for quantification of aqueous phospholipid samples. Using a capillary with trimethylphosphate as internal standard, the limit of quantification is 1.30mM. Comparison of the 31P NMR quantification method in aqueous buffer and in organic solvent revealed that the two methods...... are equal within experimental error. Changing the pH of the buffer enables peak separation for different phospholipid species. This is an advantage compared to the commercial enzyme assay based on phospholipase D and choline oxidase. The reported method, using routine 31P NMR equipment, is suitable when...... fast results of a limited number of samples are requested. © 2012 Elsevier B.V.....

  6. Can machine-learning improve cardiovascular risk prediction using routine clinical data?

    Science.gov (United States)

    Kai, Joe; Garibaldi, Jonathan M.; Qureshi, Nadeem

    2017-01-01

    Background Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Methods Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the ‘receiver operating curve’ (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). Findings 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723–0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739–0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755–0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755–0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759–0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Conclusions Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others

  7. Application of europium(III) chelates-bonded silica nanoparticle in time-resolved immunofluorometric detection assay for human thyroid stimulating hormone

    International Nuclear Information System (INIS)

    Zhou Yulin; Xia Xiaohu; Xu Ye; Ke Wei; Yang Wei; Li Qingge

    2012-01-01

    Highlights: ► A rapid and ultrasensitive TSH immunoassay was developed using fluorescent silica nanoparticles-based TrIFA. ► The assay is of high sensitivity with short period time request. ► method can be potentially used at hospitals for daily clinical practice in hTSH screening. - Abstract: Eu(III) chelate-bonded silica nanoparticle was used as a fluorescent label to develop a highly sensitive time-resolved immunofluorometric assay (TrIFA) for human thyroid stimulating hormone (hTSH). The limit of detection of the assay calculated according to the 2SD method was 0.0007 mIU L −1 and became 0.003 mIU L −1 when serum-based matrix was used for calibrators, indicating that this TrIFA is comparable with the most sensitive assays. The linear range was from 0.005 to 100 mIU L −1 of hTSH with coefficient of variation between 1.9% and 8.3%. The correlation study using 204 blood spot samples from newborns showed that the results from this new method were coincident with that of the commercial dissociation-enhanced lanthanide fluorescence immunoassay (DELFIA) system, with a correlation coefficient of 0.938. The fluorescent nanoparticle label allows directly reading the fluorescent signal, omitting the signal development step required for the DELFIA system, and the whole procedure of this assay is fulfilled within 2 h. Thus, we developed a novel, sensitive, quantitative and simple nanoparticle label-based TrIFA assay, suitable for routine application in hTSH screening of neonatal hypothyroidism.

  8. Application of europium(III) chelates-bonded silica nanoparticle in time-resolved immunofluorometric detection assay for human thyroid stimulating hormone

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Yulin [Xiamen Branch of Fujian Newborn Screening Centre and Xiamen Prenatal Diagnosis Centre, Xiamen Maternal and Children' s Health Care Hospital, Xiamen, Fujian 361003 (China); Xia Xiaohu; Xu Ye; Ke Wei [Engineering Research Centre of Molecular Diagnostics Laboratory, MOE, Department of Biomedical Sciences and the Key Laboratory of the Ministry of Education for Cell Biology and Tumor Cell Engineering, School of Life Sciences, Xiamen University, Xiamen, Fujian 361005 (China); Yang Wei, E-mail: weiyang@xmu.edu.cn [Engineering Research Centre of Molecular Diagnostics Laboratory, MOE, Department of Biomedical Sciences and the Key Laboratory of the Ministry of Education for Cell Biology and Tumor Cell Engineering, School of Life Sciences, Xiamen University, Xiamen, Fujian 361005 (China); Li Qingge, E-mail: qgli@xmu.edu.cn [Engineering Research Centre of Molecular Diagnostics Laboratory, MOE, Department of Biomedical Sciences and the Key Laboratory of the Ministry of Education for Cell Biology and Tumor Cell Engineering, School of Life Sciences, Xiamen University, Xiamen, Fujian 361005 (China)

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer A rapid and ultrasensitive TSH immunoassay was developed using fluorescent silica nanoparticles-based TrIFA. Black-Right-Pointing-Pointer The assay is of high sensitivity with short period time request. Black-Right-Pointing-Pointer method can be potentially used at hospitals for daily clinical practice in hTSH screening. - Abstract: Eu(III) chelate-bonded silica nanoparticle was used as a fluorescent label to develop a highly sensitive time-resolved immunofluorometric assay (TrIFA) for human thyroid stimulating hormone (hTSH). The limit of detection of the assay calculated according to the 2SD method was 0.0007 mIU L{sup -1} and became 0.003 mIU L{sup -1} when serum-based matrix was used for calibrators, indicating that this TrIFA is comparable with the most sensitive assays. The linear range was from 0.005 to 100 mIU L{sup -1} of hTSH with coefficient of variation between 1.9% and 8.3%. The correlation study using 204 blood spot samples from newborns showed that the results from this new method were coincident with that of the commercial dissociation-enhanced lanthanide fluorescence immunoassay (DELFIA) system, with a correlation coefficient of 0.938. The fluorescent nanoparticle label allows directly reading the fluorescent signal, omitting the signal development step required for the DELFIA system, and the whole procedure of this assay is fulfilled within 2 h. Thus, we developed a novel, sensitive, quantitative and simple nanoparticle label-based TrIFA assay, suitable for routine application in hTSH screening of neonatal hypothyroidism.

  9. A novel enterovirus and parechovirus multiplex one-step real-time PCR-validation and clinical experience

    DEFF Research Database (Denmark)

    Nielsen, A. C. Y.; Bottiger, B.; Midgley, S. E.

    2013-01-01

    As the number of new enteroviruses and human parechoviruses seems ever growing, the necessity for updated diagnostics is relevant. We have updated an enterovirus assay and combined it with a previously published assay for human parechovirus resulting in a multiplex one-step RT-PCR assay....... The multiplex assay was validated by analysing the sensitivity and specificity of the assay compared to the respective monoplex assays, and a good concordance was found. Furthermore, the enterovirus assay was able to detect 42 reference strains from all 4 species, and an additional 9 genotypes during panel...... testing and routine usage. During 15 months of routine use, from October 2008 to December 2009, we received and analysed 2187 samples (stool samples, cerebrospinal fluids, blood samples, respiratory samples and autopsy samples) were tested, from 1546 patients and detected enteroviruses and parechoviruses...

  10. Cost-effectiveness of a 21-gene recurrence score assay versus Canadian clinical practice in women with early-stage estrogen- or progesterone-receptor-positive, axillary lymph-node negative breast cancer

    International Nuclear Information System (INIS)

    Hannouf, Malek B; Xie, Bin; Brackstone, Muriel; Zaric, Gregory S

    2012-01-01

    A 21-gene recurrence score (RS) assay may inform adjuvant systematic treatment decisions in women with early stage breast cancer. We sought to investigate the cost effectiveness of using the RS-assay versus current clinical practice (CCP) in women with early-stage estrogen- or progesterone-receptor-positive, axilliary lymph-node negative breast cancer (ER+/ PR + LN- ESBC) from the perspective of the Canadian public healthcare system. We developed a Markov model to project the lifetime clinical and economic consequences of ESBC. We evaluated adjuvant therapy separately in post- and pre-menopausal women with ER+/ PR + LN- ESBC. We assumed that the RS-assay would reclassify pre- and post-menopausal women among risk levels (low, intermediate and high) and guide adjuvant systematic treatment decisions. The model was parameterized using 7 year follow up data from the Manitoba Cancer Registry, cost data from Manitoba administrative databases, and secondary sources. Costs are presented in 2010 CAD. Future costs and benefits were discounted at 5%. The RS-assay compared to CCP generated cost-savings in pre-menopausal women and had an ICER of $60,000 per QALY gained in post-menopausal women. The cost effectiveness was most sensitive to the proportion of women classified as intermediate risk by the RS-assay who receive adjuvant chemotherapy and the risk of relapse in the RS-assay model. The RS-assay is likely to be cost effective in the Canadian healthcare system and should be considered for adoption in women with ER+/ PR + LN- ESBC. However, ongoing assessment and validation of the assay in real-world clinical practice is warranted

  11. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences

    Directory of Open Access Journals (Sweden)

    Joshua J.H. Hunsaker

    2016-12-01

    Full Text Available Objectives: Refractometric methods to measure total protein (TP in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Design and methods: Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Results: Carryover risk was eliminated using a demineralized distilled water (ddH2O wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool and 0.5% CV (high TP pool. Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0% was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a low and high concentration patient pools, or b albumin-spiked ddH2O and high concentration patient pool. Decreased recovery was observed using ddH2O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL and triglycerides (>580 mg/dL. Current laboratory reference intervals for TP were verified. Conclusions: Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses. Keywords: Refractometry, Digital refractometry, Total protein, Biuret, Serum protein electrophoresis, Monoclonal

  12. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  13. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  14. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  15. A virtual asthma clinic for children: fewer routine outpatient visits, same asthma control

    NARCIS (Netherlands)

    Wijngaart, L.S. van den; Roukema, J.; Boehmer, A.L.M.; Brouwer, M.L.; Hugen, C.A.C.; Niers, L.E.M.; Sprij, A.J.; Rikkers-Mutsaerts, E.; Rottier, B.L.; Donders, A.R.T.; Verhaak, C.M.; Pijnenburg, M.W.; Merkus, P.J.

    2017-01-01

    eHealth is an appealing medium to improve healthcare and its value (in addition to standard care) has been assessed in previous studies. We aimed to assess whether an eHealth intervention could improve asthma control while reducing 50% of routine outpatient visits.In a multicentre, randomised

  16. Establishment of a 10-Plex Quantitative Fluorescent-PCR Assay for rapid diagnosis of sex chromosome aneuploidies.

    Directory of Open Access Journals (Sweden)

    Xingmei Xie

    Full Text Available Sex chromosome aneuploidies occur commonly in the general population, with an incidence of 1 in 400 newborns. However, no tests specifically targeting sex chromosomes have been carried out in prenatal diagnosis or newborn screening, resulting in late recognition of these diseases. In this study, a rapid diagnostic method for sex chromosome aneuploidies was established using Quantitative Fluorescent-PCR (QF-PCR. Ten markers were included in one multiplex QF-PCR assay, including two sex determination genes (AMXY and SRY, five X-linked short tandem repeats (STRs; DXS1053, DXS981, DXS6809, DXS1187, and DXS8377, one X/Y-common STR (X22, and two autosomal STRs (D13S305 and D21S11. Retrospective tests of 70 cases with known cytogenetic results indicated that the 10-plex QF-PCR assay could well determine sex chromosome copy numbers by both allelic peak numbers and a sex chromosome dosage calculation with the autosomal STRs as internal controls. Prospective comparison with cytogenetic karyotyping on 534 cases confirmed that the 10-plex QF-PCR assay could be well employed for sex chromosome aneuploidy diagnosis in at least the Chinese Han population. This is the first QF-PCR test for the diagnosis of sex chromosome aneuploidies in the Chinese population. This test is superior to previous designs by including up to 8 sex-linked markers covering different parts of sex chromosomes as well as employing internal controls for copy number dosage calculation in a single PCR reaction. Due to simple technique and data analysis, as well as easy implementation within routine clinical services, this method is of great clinical application value and could be widely applied.

  17. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  18. A maximum-likelihood reconstruction algorithm for tomographic gamma-ray nondestructive assay

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Estep, R.J.; Cole, R.A.; Sheppard, G.A.

    1994-01-01

    A new tomographic reconstruction algorithm for nondestructive assay with high resolution gamma-ray spectroscopy (HRGS) is presented. The reconstruction problem is formulated using a maximum-likelihood approach in which the statistical structure of both the gross and continuum measurements used to determine the full-energy response in HRGS is precisely modeled. An accelerated expectation-maximization algorithm is used to determine the optimal solution. The algorithm is applied to safeguards and environmental assays of large samples (for example, 55-gal. drums) in which high continuum levels caused by Compton scattering are routinely encountered. Details of the implementation of the algorithm and a comparative study of the algorithm's performance are presented

  19. Use of a Gantry robot in the assay of radioactive materials

    International Nuclear Information System (INIS)

    Phelan, P.F.; Beugelsdijk, T.J.; Powell, W.D.; Schneider, D.N.; Staley, H.C.; Blankenship, R.

    1989-01-01

    A large industrial robot has been installed in our plutonium processing facility to speed the assay of materials in process. The robot routinely transports radioactive items weighing 20 lbs or more between an automated inventory system and the analytical instruments. Because the system operates unattended under computer control, assays are now performed around-the-clock instead of just 8 hrs per day, thereby greatly increasing the utilization of our instruments. (When the system becomes fully operational, we except a four-fold increase in productivity.) In addition, recordkeeping has improved, the plutonium is better protected from theft, and our personnel are exposed to less radiation than before. 4 figs

  20. Loop-mediated isothermal amplification assay for rapid detection of Streptococcus agalactiae (group B streptococcus) in vaginal swabs - a proof of concept study.

    Science.gov (United States)

    McKenna, James Patrick; Cox, Ciara; Fairley, Derek John; Burke, Rachael; Shields, Michael D; Watt, Alison; Coyle, Peter Valentine

    2017-03-01

    Neonatal sepsis caused by Streptococcus agalactiae [group B streptococcus (GBS)] is a life-threatening condition, which is preventable if colonized mothers are identified and given antibiotic prophylaxis during labour. Conventional culture is time consuming and unreliable, and many available non-culture diagnostics are too complex to implement routinely at point of care. Loop-mediated isothermal amplification (LAMP) is a method that, enables the rapid and specific detection of target nucleic acid sequences in clinical materials without the requirement for extensive sample preparation. A prototype LAMP assay targeting GBS sip gene is described. The assay was 100 % specific for GBS, with a limit of detection of 14 genome copies per reaction. The clinical utility of the LAMP assay for rapid direct molecular detection of GBS was determined by testing a total of 157 vaginal swabs with minimal sample processing using a rapid lysis solution. Compared to a reference quantitative real-time PCR assay, the direct LAMP protocol had a sensitivity and specificity of 95.4 and 100 %, respectively, with positive and negative predictive values of 100 and 98.3 %, respectively. Positive and negative likelihood ratios were infinity and 0.05, respectively. The direct LAMP method required a mean time of 45 min from the receipt of a swab to generation of a confirmed result, compared to 2 h 30 min for the reference quantitative real-time PCR test. The direct LAMP protocol described is easy to perform, facilitating rapid and accurate detection of GBS in vaginal swabs. This test has a potential for use at point of care.

  1. Utility of routine postoperative chest radiography in pediatric tracheostomy.

    Science.gov (United States)

    Genther, Dane J; Thorne, Marc C

    2010-12-01

    Routine chest radiography following pediatric tracheostomy is commonly performed in order to evaluate for air-tracking complications. Routine chest radiography affords disadvantages of radiation exposure and cost. The primary objective of this study was to determine the utility of routine postoperative chest radiography following tracheostomy in pediatric patients. Secondary objectives were to compare the rates of postoperative complications by various patient and surgeon characteristics. All infants and children 18 years of age or less (n=421) who underwent tracheostomy at a single tertiary-care medical center from January 2000 to April 2009 were included in the study. A combination of data obtained from billing and administrative systems and review of electronic medical records were recorded and compiled in a database for statistical analysis. Three air-tracking complications (2 pneumothoraces and 1 pneumomediastinum) were identified in our population of 421 pediatric patients, for an incidence of 0.71% (95% CI: 0.1-2.0%). No significant relationships were found between the incidence of air-tracking complication and surgical specialty, patient age, or type of procedure (elective, urgent/emergent). Our study identified a low rate of pneumothorax and pneumomediastinum following pediatric tracheostomy. In all three cases, the pneumothorax was suspected clinically. This finding suggests that postoperative chest radiography should be reserved for cases where there is suspicion of a complication on the basis of intraoperative findings or clinical parameters. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Outcome of small cell lung cancer (SCLC) patients with brain metastases in a routine clinical setting

    International Nuclear Information System (INIS)

    Lekic, Mirko; Kovac, Viljem; Triller, Nadja; Knez, Lea; Sadikov, Aleksander; Cufer, Tanja

    2012-01-01

    Small cell lung cancer (SCLC) represents approximately 13 to 18% of all lung cancers. It is the most aggressive among lung cancers, mostly presented at an advanced stage, with median survival rates of 10 to12 months in patients treated with standard chemotherapy and radiotherapy. In approximately 15-20% of patients brain metastases are present already at the time of primary diagnosis; however, it is unclear how much it influences the outcome of disease according the other metastatic localisation. The objective of this analysis was to evaluate the median survival of SCLC patients treated by specific therapy (chemotherapy and/or radiotherapy) with regard to the presence or absence of brain metastases at the time of diagnosis. All SCLC patients have been treated in a routine clinical practice and followed up at the University Clinic Golnik in Slovenia. In the retrospective study the medical files from 2002 to 2007 were review. All patients with cytological or histological confirmed disease and eligible for specific oncological treatment were included in the study. They have been treated according to the guidelines valid at the time. Chemotherapy and regular followed-up were carried out at the University Clinic Golnik and radiotherapy at the Institute of Oncology Ljubljana. We found 251 patients eligible for the study. The median age of them was 65 years, majority were male (67%), smokers or ex-smokers (98%), with performance status 0 to 1 (83%). At the time of diagnosis no metastases were found in 64 patients (25.5%) and metastases outside the brain were presented in 153 (61.0%). Brain metastases, confirmed by a CT scan, were present in 34 patients (13.5%), most of them had also metastases at other localisations. All patients received chemotherapy and all patients with confirmed brain metastases received whole brain irradiation (WBRT). The radiotherapy with radical dose at primary tumour was delivered to 27 patients with limited disease and they got 4–6 cycles of

  3. The Diagnostic Value of Routine Contrast Esophagram in Anastomotic Leaks After Esophagectomy.

    Science.gov (United States)

    Hu, Zhongwu; Wang, Xiaowe; An, Xush; Li, Wenjin; Feng, Yun; You, Zhenbing

    2017-08-01

    Routine contrast esophagram has been shown to be increasingly limited in diagnosing anastomotic leaks after esophagectomy. Patients undergoing esophagectomy from 2013 to 2014 at Huai'an First Peoples' Hospital were identified. We retrospectively analyzed patients who underwent routine contrast esophagram on postoperative day 7 (range 6-10) to preclude anastomotic leaks after esophagectomy. In 846 patients who underwent esophagectomy, a cervical anastomosis was performed in 286 patients and an intrathoracic anastomosis in 560 patients. There were 57 (6.73%) cases with anastomotic leaks, including cervical leaks in 36 and intrathoracic leaks in 21 patients. In the cervical anastomotic leak patients, 13 were diagnosed by early local clinical symptoms and 23 underwent routine contrast esophagram. There were 7 (30.4%) true-positive, 11 (47.8%) false-negative, and five (21.8%) equivocal cases. In the intrathoracic anastomotic leak patients, four (19%) were diagnosed by clinical symptoms, 16 (76.2%) were true positives, and one (4.8%) was a false negative. Aspiration occurred in five patients with cervical anastomoses and in eight patients with intrathoracic anastomoses; aspiration pneumonitis did not occur in these cases. Gastrografin and barium are safe contrast agents to use in post-esophagectomy contrast esophagram. Because of the low sensitivity in detecting cervical anastomotic leaks, routine contrast esophagram is not advised. For patients with intrathoracic anastomoses, it is still an effective method for detecting anastomotic leaks.

  4. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    Directory of Open Access Journals (Sweden)

    Marwa Sayed Meshaal

    Full Text Available Infective endocarditis (IE is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs. These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention.The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%. Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32% had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%. The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.Routine brain CT/CTA resulted in changes in the treatment plan in a significant

  5. Bedtime routines child wellbeing & development.

    Science.gov (United States)

    Kitsaras, George; Goodwin, Michaela; Allan, Julia; Kelly, Michael P; Pretty, Iain A

    2018-03-21

    Bedtime routines has shown important associations with areas associated with child wellbeing and development. Research into bedtime routines is limited with studies mainly focusing on quality of sleep. The objectives of the present study were to examine the relationship between bedtime routines and a variety of factors associated with child wellbeing and to examine possible determinants of bedtime routines. A total of 50 families with children between 3 and 5 years old took part in the study. Data on bedtime routines, parenting styles, school readiness, children's dental health, and executive function were collected. Children in families with optimal bedtime routines showed better performance in terms of executive function, specifically working memory (t (44)= - 8.51, p ≤ .001), inhibition and attention (t (48)= - 9.70, p ≤ .001) and cognitive flexibility (t (48)= - 13.1, p ≤ .001). Also, children in households with optimal bedtime routines scored higher in their readiness for school (t (48)= 6.92, p ≤ .001) and had better dental health (U = 85.5, p = .011). Parents in households with suboptimal bedtime routines showed worse performance on all measures of executive function including working memory (t (48)= - 10.47, p ≤ .001), inhibition-attention (t (48)= - 10.50, p ≤ .001) and cognitive flexibility (t (48)= - 13.6, p ≤ .001). Finally, parents with optimal bedtime routines for their children deployed a more positive parenting style in general (i.e. authoritative parenting) compared to those with suboptimal bedtime routines (t (48)= - 6.45, p ≤ .001). The results of the present study highlight the potentially important role of bedtime routines in a variety of areas associated with child wellbeing and the need for further research.

  6. What is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.

    Science.gov (United States)

    Czoski-Murray, C; Lloyd Jones, M; McCabe, C; Claxton, K; Oluboyede, Y; Roberts, J; Nicholl, J P; Rees, A; Reilly, C S; Young, D; Fleming, T

    2012-12-01

    The evidence base which supported the National Institute for Health and Clinical Excellence (NICE) published Clinical Guideline 3 was limited and 50% was graded as amber. However, the use of tests as part of pre-operative work-up remains a low-cost but high-volume activity within the NHS, with substantial resource implications. The objective of this study was to identify, evaluate and synthesise the published evidence on the clinical effectiveness and cost-effectiveness of the routine use of three tests, full blood counts (FBCs), urea and electrolytes tests (U&Es) and pulmonary function tests, in the pre-operative work-up of otherwise healthy patients undergoing minor or intermediate surgery in the NHS. The aims of this study were to estimate the clinical effectiveness and cost-effectiveness of routine pre-operative testing of FBC, electrolytes and renal function and pulmonary function in adult patients classified as American Society of Anaesthesiologists (ASA) grades 1 and 2 undergoing elective minor (grade 1) or intermediate (grade 2) surgical procedures; to compare NICE recommendations with current practice; to evaluate the cost-effectiveness of mandating or withdrawing each of these tests in this patient group; and to identify the expected value of information and whether or not it has value to the NHS in commissioning further primary research into the use of these tests in this group of patients. The following electronic bibliographic databases were searched: (1) BIOSIS; (2) Cumulative Index to Nursing and Allied Health Literature; (3) Cochrane Database of Systematic Reviews; (4) Cochrane Central Register of Controlled Trials; (5) EMBASE; (6) MEDLINE; (7) MEDLINE In-Process & Other Non-Indexed Citations; (8) NHS Database of Abstracts of Reviews of Effects; (9) NBS Health Technology Assessment Database; and (10) Science Citation Index. To identify grey and unpublished literature, the Cochrane Register of Controlled Trials, National Research Register Archive

  7. Screening of intraocular pressure before routine pupil dilation for retinal photography: Clinical case report

    Directory of Open Access Journals (Sweden)

    Lap-kin Chiang

    2016-12-01

    Full Text Available Introduction: Pharmacologic dilation of the pupil results in twice the sensitivity of detection of diabetic retinopathy compared with undilated retinal examination. The potential risk of acute angle-closure glaucoma after pupil dilation has been hypothesized to be higher in Asian patients with diabetes mellitus. Clinical case: A 61-year-old man with diabetes mellitus and hypertension was incidentally found to have elevated intraocular pressure (IOP before routine retinal photography. He was asymptomatic and the visual acuity was 0.67 for both eyes. An ophthalmologist later found he had anatomical narrow-angle borderline glaucoma. Topical administration of pilocarpine and oral administration of acetazolamide were initiated, and laser iridotomy was later performed. IOP screening: Among 1736 diabetic and/or hypertensive patients who underwent IOP screening, 31 patients (1.8% had IOP of any eye persistently higher than 21 mm Hg on at least two occasions. The mean (standard deviation IOP of the right eye was 24.1 (2.1 mm Hg, while that of the left eye was 24.6 (2.5 mm Hg. Four patients (12.9% were found to have glaucoma, and treatment was initiated by an ophthalmologist. Therefore further study should be conducted to evaluate the cost-effectiveness of IOP screening among this group of patients.

  8. Development of a reverse transcriptase loop-mediated isothermal amplification (LAMP) assay for the sensitive detection of Leishmania parasites in clinical samples

    NARCIS (Netherlands)

    Adams, Emily R.; Schoone, Gerard J.; Ageed, Al Farazdag; El Safi, Sayda; Schallig, Henk D. F. H.

    2010-01-01

    Here we describe a generic, reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay, for the identification of Leishmania species from clinical samples. LAMP is an isothermal reaction recently developed as a point-of-care diagnostic tool. Primers were designed in the conserved

  9. Clinical implications of a new TSH-receptor-antibody-assay (DYNOtest {sup trademark} TRAKhuman) in autoimmune thyroid diseases; Klinische Implikationen eines neuen TSH-Rezeptor-Antikoerper-Assays (DYNOtest {sup trademark} TRAKhuman) bei autoimmunen Schilddruesenerkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Meller, J.; Schreivogel, I.; Becker, W. [Goettingen Univ. (Germany). Abt. fuer Nuklearmedizin; Bergmann, A.; Morgenthaler, N. [B.R.A.H.M.S Diagnostica, Berlin (Germany); Huefner, M. [Goettingen Univ. (Germany). Abt. Innere Medizin

    2000-07-01

    Aim: Conventional radioreceptor-antibody-assays (RAAs) fail in the detection of TSH-receptor antibodies (TRAKs) in 10-30% of patients with Graves' disease (GD). The aim of this study was the evaluation of the diagnostic and clinical impact of a new RRA (DYNOtest {sup trademark} TRAKhuman) which uses the human recombinant TSH-Receptor in the diagnosis of autoimmune thyroid disease. Methods: Sera from 142 consecutive patients (GD: n=50, autoimmune thyroiditis/AIT: n=92) and from 55 controls (31 patients without any thyroid disease and 14 with euthyroid goiter) were evaluated both with the DYNOtest {sup trademark} TRAKhuman-assay and a conventional RRA (TRAK-Assay {sup trademark}). Thyroid in vitro parameters and thyroid sonography were performed in all patients. Results: The DYNOtest {sup trademark} TRAK-assay was significantly superior to the conventional RRA in the diagnosis of GD (p<0,00012), especially in those who were treated by thionamides (p<0,003) and in the diagnosis of TRAK-positive patients with AIT (p<0,003). The majority of TRAK-positive AIT-patients suffered from hypothyroidism. One false positive result in patients with euthyroid goiter was found in the TRAK-Assay {sup trademark} as well as in the DYNOtest {sup trademark} TRAKhuman-Assay. Therefore the specifity of the DYNOtest {sup trademark} TRAKhuman was not inferior compared with the conventional assay. Conclusion: The DYNOtest {sup trademark} TRAK-assay is superior in the diagnostic work up of Graves' disease compared with a conventional TRAK-assay and offers an equal specifity. (orig.) [German] Ziel: Bei konventionellen Radiorezeptor-Antikoerper-Assays (RRAs) misslingt der Nachweis von TSH-Rezeptor Antikoerpern (TRAKS) bei 10-30% der immunogenen Hyperthyreosen (IH). Ziel der Studie war es, den diagnostischen und klinischen Stellenwertes eines neuen RRA (DYNOtest {sup trademark} TRAKhuman) bei autoimmunen Schilddruesenerkrankungen zu evaluieren. Methoden: Serumproben von 142

  10. Detection of pathogenic elephant endotheliotropic herpesvirus in routine trunk washes from healthy adult Asian elephants (Elephas maximus) by use of a real-time quantitative polymerase chain reaction assay

    Science.gov (United States)

    Stanton, Jeffrey J.; Zong, Jian-Chao; Latimer, Erin; Tan, Jie; Herron, Alan; Hayward, Gary S.; Ling, Paul D.

    2013-01-01

    Objective To investigate the pathogenesis and transmission of elephant endotheliotropic herpesvirus (EEHV1) by analyzing various elephant fluid samples with a novel EEHV1-specific real-time PCR assay. Animals 5 apparently healthy captive Asian elephants (Elephas maximus) from the same herd. Procedures A real-time PCR assay was developed that specifically detects EEHV1. The assay was used to evaluate paired whole blood and trunk-wash samples obtained from the 5 elephants during a 15-week period. Deoxyribonucleic acid sequencing and viral gene subtyping analysis were performed on trunk-wash DNA preparations that had positive results for EEHV1. Viral gene subtypes were compared with those associated with past fatal cases of herpesvirus-associated disease within the herd. Results The PCR assay detected viral DNA to a level of 1,200 copies/mL of whole blood. It was used to detect EEHV1 in trunk secretions of 3 of the 5 elephants surveyed during the 15-week period. Viral gene subtyping analysis identified 2 distinct elephant herpesviruses, 1 of which was identical to the virus associated with a previous fatal case of herpesvirus-associated disease within the herd. Conclusions and Clinical Relevance EEHV1 was shed in the trunk secretions of healthy Asian elephants. Trunk secretions may provide a mode of transmission for this virus. Results of this study may be useful for the diagnosis, treatment, and management of EEHV1-associated disease and the overall management of captive elephant populations. PMID:20673092

  11. A practical approach for the validation and clinical implementation of a high-sensitivity cardiac troponin I assay across a North American city

    Directory of Open Access Journals (Sweden)

    Peter A. Kavsak

    2015-04-01

    Full Text Available Objectives: Despite several publications on the analytical performance of high-sensitivity cardiac troponin (hs-cTn assays, there has been little information on how laboratories should validate and implement these assays into clinical service. Our study provides a practical approach for the validation and implementation of a hs-cTn assay across a large North American City. Design and methods: Validation for the Abbott ARCHITECT hs-cTnI assay (across 5 analyzers consisted of verification of limit of blank (LoB, precision (i.e., coefficient of variation; CV testing at the reported limit of detection (LoD and within and outside the 99th percentile, linearity testing, cTnI versus hs-cTnI patient comparison within and between analyzers (Passing and Bablok and non-parametric analyses. Education, clinical communications, and memorandums were issued in advance to inform all staff across the city as well as a selected reminder the day before live-date to important users. All hospitals switched to the hs-cTnI assay concurrently (the contemporary cTnI assay removed with laboratory staff instructed to repeat samples previously measured with the contemporary cTnI assay with the hs-cTnI assay only by physician request. Results: Across the 5 analyzers and 6 reagent packs the overall LoB was 0.6 ng/L (n=60 with a CV of 33% at an overall mean of 1.2 ng/L (n=60; reported LoD=1.0 ng/L, with linearity demonstrated from 45,005 ng/L to 1.1 ng/L. Precision testing with a normal patient-pool QC material (mean range across 5 analyzers was 3.9–4.4 ng/L yielded a range of CVs from 7% to 10% (within-run and CVs from 7% to 18% (between-run with the high patient-pool QC material (mean range across 5 analyzers was 29.6–36.3 ng/L yielding a range of CVs from 2% to 5% (within-run and CVs from 4% to 8% (between-run. There was agreement between hs-cTnI versus cTnI with the patient samples (slope ranges: 0.89–1.03; intercept ranges: 1.9–3

  12. Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

    International Nuclear Information System (INIS)

    Suhy, Il Kyo; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

    1987-01-01

    To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit (Abott and Daichi). Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 volunteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intraassay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/1 respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU,/l. Mean recovery rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/1 and 2.85-30.8 mU/1 repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function

  13. Potency assay design for adjuvanted recombinant proteins as malaria vaccines.

    Science.gov (United States)

    Giersing, Birgitte K; Dubovsky, Filip; Saul, Allan; Denamur, Francoise; Minor, Philip; Meade, Bruce

    2006-05-15

    Many licensed vaccines are composed of live, attenuated or inactivated whole-cell microorganisms, or they comprise purified components from whole-cell extracts or culture supernatants. For some diseases, pathology is fairly well understood, and there may be known correlates of protection that provide obvious parameters for assessment of vaccine potency. However, this is not always the case, and some effective vaccines are routinely used even though the mechanisms or correlates of protection are unknown. Some more modern vaccine approaches employ purified recombinant proteins, based on molecules that appear on the surface of the pathogen. This is one of the strategies that has been adopted in the quest to develop a malaria vaccine. Use of these parasite antigens as vaccine candidates is supported by substantial epidemiological data, and some have demonstrated the ability to elicit protective responses in animal models of malaria infection. However, there is as yet no immunological correlate of protection and no functional assays or animal models that have demonstrated the ability to predict efficacy in humans. There is little precedence for the most appropriate and practical method for assessing potency of vaccines based on these recombinant molecules for malaria vaccines. This is likely because the majority of malaria vaccine candidates have only recently entered clinical evaluation. The PATH Malaria Vaccine Initiative (MVI) convened a panel with expertise in potency assay design from industry, governmental institutions, and regulatory bodies to discuss and review the rationale, available methods, and best approaches for assessing the potency of recombinant proteins, specifically for their use as malarial vaccines. The aim of this meeting was to produce a discussion document on the practical potency assessment of recombinant protein malaria vaccines, focusing on early phase potency assay development.

  14. Human Papillomavirus Assays and Cytology in Primary Cervical Screening of Women Aged 30 Years and Above

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Preisler, Sarah

    2016-01-01

    In women aged ≥30 years, Human Papillomavirus testing will replace cytology for primary cervical screening. We compared Hybrid Capture 2 (HC2), cobas, CLART, and APTIMA HPV assays with cytology on 2869 SurePath samples from women undergoing routine screening at 30-65 years in Copenhagen, Denmark....... Women with cytological abnormalities were managed according to routine recommendations, with 92% completeness. Those with cytology-normal/HPV-positive samples (on any of the four assays) were invited for repeated cytology and HPV testing in 1.5 year, and 58% had additional testing. HPV testing detected...... more ≥CIN3 than cytology (HC2: 35, cobas, CLART: 37, APTIMA: 34, cytology: 31), although statistically the differences were not significant. Cobas and CLART detected significantly more ≥CIN2 than cytology (cobas, CLART: 49, cytology: 39). The proportion of women with false-positive test results...

  15. What is the yield of routine chest radiography following tube thoracostomy for trauma?

    Science.gov (United States)

    Kong, Victor Y; Oosthuizen, George V; Clarke, Damian L

    2015-01-01

    Routine chest radiography (CXR) following tube thoracostomy (TT) is a standard practice in most trauma centres worldwide. Evidence supporting this routine practice is lacking and the actual yield is unknown. We performed a retrospective review of 1042 patients over a 4-year period who had a routine post-insertion CXR performed in accordance with current ATLS® recommendations. A total 1042 TTs were performed on 1004 patients. Ninety-one per cent of patients (913/1004) were males, and the median age for all patients was 24 years. Seventy-five per cent of all injuries (756/1004) were from penetrating trauma, and the remaining 25% (248/1004) were from blunt. The initial pathologies requiring TT were: haemopneumothorax: 34% (339/1042), haemothroax: 31% (314/1042), simple pneumothorax: 25% (256/1042), tension pneumothorax: 8% (77/1042) and open pneumothorax: 5% (54/1042). One hundred and three patients had TTs performed on clinical grounds alone without a pre-insertion CXR [Group A]. One hundred and ninety-one patients had a pre-insertion CXR but had persistent clinical concerns following insertion [Group B]. Seven hundred and ten patients had pre-insertion CXR but no clinical concerns following insertion [Group C]. Overall, 15% (152/1004) [9 from Group A, 111 from Group B and 32 from Group C] of all patients had their clinical management influenced as a direct result of the post-insertion CXR. Despite the widely accepted practice of routine CXR following tube thoracostomy, the yield is relatively low. In many cases, good clinical examination post tube insertion will provide warnings as to whether problems are likely to result. However, in the more rural setting, and in resource challenged environments, there is a relatively high yield from the CXR, which alters management. Further prospective studies are needed to establish or refute the role of the existing ATLS® guidelines in these specific environments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of Two Molecular Assays for Detection and Characterization of Aspergillus fumigatus Triazole Resistance and Cyp51A Mutations in Clinical Isolates and Primary Clinical Samples of Immunocompromised Patients

    Directory of Open Access Journals (Sweden)

    Patricia Postina

    2018-03-01

    Full Text Available In hematological patients, the incidence of invasive aspergillosis (IA caused by azole resistant Aspergillus fumigatus (ARAf is rising. As the diagnosis of IA is rarely based on positive culture in this group of patients, molecular detection of resistance mutations directly from clinical samples is crucial. In addition to the in-house azole resistance ARAf polymerase chain reaction (PCR assays detecting the frequent mutation combinations TR34/L98H, TR46/Y121F/T289A, and M220 in the Aspergillus fumigatus (A. fumigatus Cyp51A gene by subsequent DNA sequence analysis, we investigated in parallel the commercially available AsperGenius® real time PCR system in detecting the Cyp51A alterations TR34/L98H and Y121F/T289A directly from 52 clinical samples (15 biopsies, 22 bronchoalveolar lavage (BAL, 15 cerebrospinal fluid (CSF samples and ARAf isolates (n = 3 of immunocompromised patients. We analyzed DNA aliquots and compared both methods concerning amplification and detection of Aspergillus DNA and Cyp51A alterations. As positive control for the feasibility of our novel Y121F and T289A PCR assays, we used two A. fumigatus isolates with the TR46/Y121F/T289A mutation combination isolated from hematological patients with known Cyp51A alterations and a lung biopsy sample of a patient with acute myeloid leukemia (AML. The rate of positive ARAf PCR results plus successful sequencing using the ARAf PCR assays was 61% in biopsies, 29% in CSF, 67% in BAL samples and 100% in isolates. In comparison the amount of positive PCRs using the AsperGenius® assays was 47% in biopsies, 42% in CSF, 59% in BAL samples and 100% in isolates. Altogether 17 Cyp51A alterations were detected using our ARAf PCRs plus DNA sequencing and therefrom 10 alterations also by the AsperGenius® system. The comparative evaluation of our data revealed that our conventional PCR assays are more sensitive in detecting ARAf in BAL and biopsy samples, whereby differences were not significant

  18. Molecular markers for urothelial bladder cancer prognosis: toward implementation in clinical practice.

    Science.gov (United States)

    van Rhijn, Bas W G; Catto, James W; Goebell, Peter J; Knüchel, Ruth; Shariat, Shahrokh F; van der Poel, Henk G; Sanchez-Carbayo, Marta; Thalmann, George N; Schmitz-Dräger, Bernd J; Kiemeney, Lambertus A

    2014-10-01

    To summarize the current status of clinicopathological and molecular markers for the prediction of recurrence or progression or both in non-muscle-invasive and survival in muscle-invasive urothelial bladder cancer, to address the reproducibility of pathology and molecular markers, and to provide directions toward implementation of molecular markers in future clinical decision making. Immunohistochemistry, gene signatures, and FGFR3-based molecular grading were used as molecular examples focussing on prognostics and issues related to robustness of pathological and molecular assays. The role of molecular markers to predict recurrence is limited, as clinical variables are currently more important. The prediction of progression and survival using molecular markers holds considerable promise. Despite a plethora of prognostic (clinical and molecular) marker studies, reproducibility of pathology and molecular assays has been understudied, and lack of reproducibility is probably the main reason that individual prediction of disease outcome is currently not reliable. Molecular markers are promising to predict progression and survival, but not recurrence. However, none of these are used in the daily clinical routine because of reproducibility issues. Future studies should focus on reproducibility of marker assessment and consistency of study results by incorporating scoring systems to reduce heterogeneity of reporting. This may ultimately lead to incorporation of molecular markers in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. The impact of routine open nonsuction drainage on fluid accumulation after thyroid surgery: a prospective randomised clinical trial.

    LENUS (Irish Health Repository)

    Neary, Peter M

    2012-01-01

    Thyroid drains following thyroid surgery are routinely used despite minimal supportive evidence. Our aim in this study is to determine the impact of routine open drainage of the thyroid bed postoperatively on ultrasound-determined fluid accumulation at 24 hours.

  20. Extrapulmonary involvement in patients with sarcoidosis and comparison of routine laboratory and clinical data to pulmonary involvement.

    Science.gov (United States)

    Zurkova, Monika; Kolek, Vitezslav; Tomankova, Tereza; Kriegova, Eva

    2014-12-01

    Patients with pulmonary and pulmonary plus extrapulmonary sarcoidosis differ in symptom severity and health status impairment. To date there is no information on differences in clinical and laboratory parameters between these phenotypes and limited information on extrapulmonary involvement in Czech sarcoidosis patients exists. We therefore compared clinical data (age, gender, organ involvement, lung function tests) and laboratory data (blood counts, bronchoalveolar fluid (BAL) cellular profile, serum levels of CRP, SACE, sIL-2R, neopterin) between patients with newly diagnosed pulmonary sarcoidosis (n=107) and those with pulmonary plus extrapulmonary sarcoidosis (n=54). Extrapulmonary sarcoidosis was diagnosed in 33% of patients, mostly affecting lymph nodes and skin and having hypercalciuria. There was no difference in the prevalence of extrapulmonary sarcoidosis between genders. Patients with extrapulmonary sarcoidosis were older and mostly non-smokers when compared to those with limited pulmonary form. X-ray Stage I and erythema nodosum were less frequent in extrapulmonary disease. Serum levels of CRP, SACE, sIL-2R and neopterin and BAL cellular profile did not differ between both phenotypes. We observed lower platelets, FEV1, VC, and BAL CD19+ in females with extrapulmonary involvement than in those with pulmonary disease. Affected lymph nodes, skin and hypercalciuria were the most common in sarcoidosis patients with extrapulmonary involvement. Pulmonary sarcoidosis did not differ in clinical and routine laboratory parameters from pulmonary plus extrapulmonary sarcoidosis. Observation of low platelets, VC, FEV1 and BAL CD19+ in females with extrapulmonary sarcoidosis needs further verification in larger cohort.

  1. Verification of an immunoturbidimetric assay for heart-type fatty acid-binding protein (H-FABP) on a clinical chemistry platform and establishment of the upper reference limit.

    Science.gov (United States)

    Da Molin, Simona; Cappellini, Fabrizio; Falbo, Rosanna; Signorini, Stefano; Brambilla, Paolo

    2014-11-01

    Heart-type fatty acid-binding protein (H-FABP) is an early biomarker of cardiac injury. Randox Laboratories developed an immunoturbidimetric H-FABP assay for non-proprietary automated clinical chemistry analysers that could be useful in the emergency department. We verified the analytical performances claimed by Randox Laboratories on Roche Cobas 6000 clinical chemistry platform in use in our laboratory, and we defined our own 99th percentile upper reference limit for H-FABP. For the verification of method performances, we used pools of spared patient samples from routine and two levels of quality control material, while samples for the reference value study were collected from 545 blood donors. Following CLSI guidelines we verified limit of blank (LOB), limit of detection (LOD), limit of quantitation (LOQ), repeatability and within-laboratory precision, trueness, linearity, and the stability of H-FABP in EDTA over 24h. The LOQ (3.19 μg/L) was verified with a CV% of 10.4. The precision was verified for the low (mean 5.88 μg/L, CV=6.7%), the medium (mean 45.28 μg/L, CV=3.0%), and the high concentration (mean 88.81 μg/L, CV=4.0%). The trueness was verified as well as the linearity over the indicated measurement interval of 0.747-120 μg/L. The H-FABP in EDTA samples is stable throughout 24h both at room temperature and at 4 °C. The H-FABP 99th percentile upper reference limit for all subjects (3.60 μg/L, 95% CI 3.51-3.77) is more appropriate than gender-specific ones that are not statistically different. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of a PCR assay for identification and differentiation of Campylobacter fetus subspecies

    DEFF Research Database (Denmark)

    Hum, S.; Quinn, K.; Brunner, J.

    1997-01-01

    methods were attributed to methodological differences used in various laboratories. Conclusion Our results indicate that misidentification of C fetus in routine diagnostic laboratories may be relatively common. The PCR assay evaluated gave rapid and reproducible results and is thus a valuable adjunctive......Objective To evaluate a polymerase chain reaction assay for identification of Campylobacter fetus and differentiation of the defined subspecies. Design Characterisation of bacterial strains by traditional phenotyping, polymerase chain reaction, a probabilistic identification scheme...... by traditional phenotypic methods and the PCR assay was found to be 80.8%. The polymerase chain reaction proved to be a reliable technique for the species and subspecies identification of C fetus; equivocal results were obtained in only two instances. Initial misidentifications by conventional phenotyping...

  3. Outcome measures in European patients with haemophilia: Survey of implementation in routine clinical practice, perception of relevance and recommendations by European treaters in the EHTSB.

    Science.gov (United States)

    Hermans, C; Klamroth, R; Richards, M; de Moerloose, P; Garrido, R P

    2017-03-01

    This study was conducted to evaluate the current implementation of outcome measures in routine clinical haemophilia practice and to explore and appreciate the perception of the relevance of such measures by treaters. A survey was completed by 19 of the 26 physicians involved in the European Haemophilia Therapy Strategy Board (EHTSB). Employing an extensive inventory of outcome measures used in patients with haemophilia, information was collected about the frequency of data collection and the subjective appreciation of their importance during clinic review. The survey revealed that most treaters currently collect data that are mainly related to the haemostatic treatment (consumption of concentrates) and the bleeding symptoms (number and location of bleeds) in a non-uniform and non-standardized way. By contrast, functional, physical and quality of life scorings are rarely used and show considerable heterogeneity between treaters. Also, many disparities emerged between practice and perception, in particular quality of life data that are perceived as being important but for most of the time are not collected. This survey represents, in our view, the first attempt to evaluate the actual utilization of outcome measures in haemophilia care. While the value of outcome measures is appreciated, they are not assessed regularly. Therefore, there is a need to include appropriate performance indicators (outcome measures) of haemophilia care in routine clinical practice. Consensus recommendations to provide a framework for achieving this aim are provided. © 2016 John Wiley & Sons Ltd.

  4. Evaluation of a molybdenum assay canister

    International Nuclear Information System (INIS)

    Yoshizumi, T.T.; Keener, S.J.

    1988-01-01

    The performance characteristics of a commercial molybdenum assay canister were evaluated. The geometrical variation of the technetium-99m (/sup 99m/Tc) activity reading was studied as a function of the elution volume for the standard vials. It was found that the /sup 99m/Tc canister activity reading was ∼ 5% lower than that of the standard method. This is due to attenuation by the canister wall. However, the effect of the geometric variation on the clinical dose preparation was found to be insignificant. The molybdenum-99 ( 99 Mo) contamination level was compared by two methods: (1) the commercial canister and (2) the standard assay kit. The 99 Mo contamination measurements with the canister indicated consistently lower readings than those with the standard 99 Mo assay kit. The authors conclude that the canister may be used in the clinical settings. However, the user must be aware of the problems and the limitations associated with this canister

  5. Effectiveness and cost of atypical versus typical antipsychotic treatment for schizophrenia in routine care.

    Science.gov (United States)

    Stargardt, Tom; Weinbrenner, Susanne; Busse, Reinhard; Juckel, Georg; Gericke, Christian A

    2008-06-01

    In two recent randomised clinical trials, a meta-analysis and in an effectiveness study analysing routine data from the U.S. Veterans Administration the superiority of the newer atypical drugs over typical antipsychotic drugs, concerning both their efficacy and their side-effect profile, has been questioned. To analyse the effectiveness and cost of atypical versus typical antipsychotic treatment for schizophrenia in routine care. Cohort study using routine care data from a statutory sickness fund with 5.4 million insured in Germany. To be included, patients had to be discharged with a diagnosis of schizophrenia in 2003 and fulfil membership criteria. Main outcome measures were rehospitalisation rates, mean hospital bed days, mean length of stay, cost of inpatient and pharmaceutical care to the sickness fund during follow-up and medication used to treat side-effects. 3121 patients were included into the study. There were no statistically significant differences in the effectiveness of atypical and typical antipsychotics on rehospitalisation during follow-up (rehospitalisation rate ratio 1.07, 95% confidence interval 0.86 to 1.33). However, there were consistent observations of atypical antipsychotics being more effective for severe cases of schizophrenia (14.6% of study population; >61 prior bed days per year in 2000-2002) in the follow-up period, whereas for the other severity strata typical antipsychotics seemed more effective in reducing various rehospitalisation outcomes. Patients treated with atypical antipsychotics received significantly less prescriptions for anticholinergics or tiaprid (relative risk 0.26, 95% confidence interval 0.18 to 0.38). The effectiveness of atypical antipsychotics for schizophrenia on rehospitalisation measures appeared similar to that of typical antipsychotics. With the exception of severe cases, the higher costs for atypical antipsychotics were not offset by savings from reduced inpatient care. Major limitations include the lack of

  6. Routine conventional karyotyping of lymphoma staging bone marrow samples does not contribute clinically relevant information.

    Science.gov (United States)

    Nardi, Valentina; Pulluqi, Olja; Abramson, Jeremy S; Dal Cin, Paola; Hasserjian, Robert P

    2015-06-01

    Bone marrow (BM) evaluation is an important part of lymphoma staging, which guides patient management. Although positive staging marrow is defined as morphologically identifiable disease, such samples often also include flow cytometric analysis and conventional karyotyping. Cytogenetic analysis is a labor-intensive and costly procedure and its utility in this setting is uncertain. We retrospectively reviewed pathological reports of 526 staging marrow specimens in which conventional karyotyping had been performed. All samples originated from a single institution from patients with previously untreated Hodgkin and non-Hodgkin lymphomas presenting in an extramedullary site. Cytogenetic analysis revealed clonal abnormalities in only eight marrow samples (1.5%), all of which were positive for lymphoma by morphologic evaluation. Flow cytometry showed a small clonal lymphoid population in three of the 443 morphologically negative marrow samples (0.7%). Conventional karyotyping is rarely positive in lymphoma staging marrow samples and, in our cohort, the BM karyotype did not contribute clinically relevant information in the vast majority of cases. Our findings suggest that karyotyping should not be performed routinely on BM samples taken to stage previously diagnosed extramedullary lymphomas unless there is pathological evidence of BM involvement by lymphoma. © 2015 Wiley Periodicals, Inc.

  7. Utility of the Abbott RealTime HCV Genotype Plus RUO assay used in combination with the Abbott RealTime HCV Genotype II assay.

    Science.gov (United States)

    He, Chao; Germer, Jeffrey J; Ptacek, Elizabeth R; Bommersbach, Carl E; Mitchell, P Shawn; Yao, Joseph D C

    Hepatitis virus C (HCV) genotype (GT) determination and subtype (ST) differentiation (1a versus 1b) remain important for the selection of appropriate direct-acting antiviral (DAA) therapy. This study is a retrospective comparison of HCV GT and ST result distribution when using the Abbott RealTime HCV Genotype II assay (HCVGT II) alone and in combination with the Abbott RealTime HCV Genotype Plus RUO assay (HCVGT Plus) for routine testing of clinical serum specimens at a reference laboratory. HCVGT II results of specimens tested from June 2014 through January 2016 (period 1) were compared with combined results from HCVGT II and HCVGT Plus (HCVGT II/Plus) performed from January 2016 through January 2017 (period 2). A total of 44,127 and 25,361 specimens were tested during periods 1 and 2, respectively. Use of HCVGT II/Plus significantly reduced the frequency of GT 1 results without ST (0.4%) when compared to preliminary HCVGT II results during period 2 (5.3%; p < 0.01) and final HCVGT II results in period 1 (5.5%; p < 0.01). HCVGT II/Plus also resulted in GT 6 reactivity in 38 specimens with results of "HCV detected" (n = 17) or GT 1 (n = 21) following initial HCVGT II testing during period 2. When compared to the use of HCVGT II alone, HCVGT II/Plus significantly reduced the frequency of GT 1 without ST results observed in a large reference laboratory, while also enabling the identification of HCV GT 6. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Additive value of amyloid-PET in routine cases of clinical dementia work-up after FDG-PET

    International Nuclear Information System (INIS)

    Brendel, Matthias; Schnabel, Jonas; Wagner, Leonie; Brendel, Eva; Meyer-Wilmes, Johanna; Unterrainer, Marcus; Schoenecker, Sonja; Prix, Catharina; Ackl, Nibal; Schildan, Andreas; Patt, Marianne; Barthel, Henryk; Sabri, Osama; Catak, Cihan; Pogarell, Oliver; Levin, Johannes; Danek, Adrian; Buerger, Katharina; Bartenstein, Peter; Rominger, Axel

    2017-01-01

    In recent years, several [ 18 F]-labeled amyloid-PET tracers have been developed and have obtained clinical approval. Despite their widespread scientific use, studies in routine clinical settings are limited. We therefore investigated the impact of [ 18 F]-florbetaben (FBB)-PET on the diagnostic management of patients with suspected dementia that was still unclarified after [ 18 F]-fluordeoxyglucose (FDG)-PET. All subjects were referred in-house with a suspected dementia syndrome due to neurodegenerative disease. After undergoing an FDG-PET exam, the cases were discussed by the interdisciplinary dementia board, where the most likely diagnosis as well as potential differential diagnoses were documented. Because of persistent diagnostic uncertainty, the patients received an additional FBB-PET exam. Results were interpreted visually and classified as amyloid-positive or amyloid-negative, and we then compared the individual clinical diagnoses before and after additional FBB-PET. A total of 107 patients (mean age 69.4 ± 9.7y) were included in the study. The FBB-PET was rated as amyloid-positive in 65/107. In 83% of the formerly unclear cases, a final diagnosis was reached through FBB-PET, and the most likely prior diagnosis was changed in 28% of cases. The highest impact was observed for distinguishing Alzheimer's dementia (AD) from fronto-temporal dementia (FTLD), where FBB-PET altered the most likely diagnosis in 41% of cases. FBB-PET has a high additive value in establishing a final diagnosis in suspected dementia cases when prior investigations such as FDG-PET are inconclusive. The differentiation between AD and FTLD was particularly facilitated by amyloid-PET, predicting a considerable impact on patient management, especially in the light of upcoming disease-modifying therapies. (orig.)

  9. Additive value of amyloid-PET in routine cases of clinical dementia work-up after FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Brendel, Matthias; Schnabel, Jonas; Wagner, Leonie; Brendel, Eva; Meyer-Wilmes, Johanna; Unterrainer, Marcus [University Hospital, LMU Munich, Department of Nuclear Medicine, Munich (Germany); Schoenecker, Sonja; Prix, Catharina; Ackl, Nibal [University Hospital, LMU Munich, Department of Neurology, Munich (Germany); Schildan, Andreas; Patt, Marianne; Barthel, Henryk; Sabri, Osama [University of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Catak, Cihan [Klinikum der Universitaet Muenchen, Institute for Stroke and Dementia Research, Munich (Germany); Pogarell, Oliver [University Hospital, LMU Munich, Department of Psychiatry, Munich (Germany); Levin, Johannes; Danek, Adrian [University Hospital, LMU Munich, Department of Neurology, Munich (Germany); DZNE - German Center for Neurodegenerative Diseases, Munich (Germany); Buerger, Katharina [Klinikum der Universitaet Muenchen, Institute for Stroke and Dementia Research, Munich (Germany); DZNE - German Center for Neurodegenerative Diseases, Munich (Germany); Bartenstein, Peter; Rominger, Axel [University Hospital, LMU Munich, Department of Nuclear Medicine, Munich (Germany); Munich Cluster for Systems Neurology (SyNergy), Munich (Germany)

    2017-12-15

    In recent years, several [{sup 18}F]-labeled amyloid-PET tracers have been developed and have obtained clinical approval. Despite their widespread scientific use, studies in routine clinical settings are limited. We therefore investigated the impact of [{sup 18}F]-florbetaben (FBB)-PET on the diagnostic management of patients with suspected dementia that was still unclarified after [{sup 18}F]-fluordeoxyglucose (FDG)-PET. All subjects were referred in-house with a suspected dementia syndrome due to neurodegenerative disease. After undergoing an FDG-PET exam, the cases were discussed by the interdisciplinary dementia board, where the most likely diagnosis as well as potential differential diagnoses were documented. Because of persistent diagnostic uncertainty, the patients received an additional FBB-PET exam. Results were interpreted visually and classified as amyloid-positive or amyloid-negative, and we then compared the individual clinical diagnoses before and after additional FBB-PET. A total of 107 patients (mean age 69.4 ± 9.7y) were included in the study. The FBB-PET was rated as amyloid-positive in 65/107. In 83% of the formerly unclear cases, a final diagnosis was reached through FBB-PET, and the most likely prior diagnosis was changed in 28% of cases. The highest impact was observed for distinguishing Alzheimer's dementia (AD) from fronto-temporal dementia (FTLD), where FBB-PET altered the most likely diagnosis in 41% of cases. FBB-PET has a high additive value in establishing a final diagnosis in suspected dementia cases when prior investigations such as FDG-PET are inconclusive. The differentiation between AD and FTLD was particularly facilitated by amyloid-PET, predicting a considerable impact on patient management, especially in the light of upcoming disease-modifying therapies. (orig.)

  10. Optimized enzyme-linked immunosorbent assay for detecting cytomegalovirus infections during clinical trials of recombinant vaccines.

    Science.gov (United States)

    Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine

    2017-11-01

    In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Development of a real-time RT-PCR and Reverse Line probe Hybridisation assay for the routine detection and genotyping of Noroviruses in Ireland.

    LENUS (Irish Health Repository)

    Menton, John F

    2007-01-01

    BACKGROUND: Noroviruses are the most common cause of non-bacterial gastroenteritis. Improved detection methods have seen a large increase in the number of human NoV genotypes in the last ten years. The objective of this study was to develop a fast method to detect, quantify and genotype positive NoV samples from Irish hospitals. RESULTS: A real-time RT-PCR assay and a Reverse Line Blot Hybridisation assay were developed based on the ORF1-ORF2 region. The sensitivity and reactivity of the two assays used was validated using a reference stool panel containing 14 NoV genotypes. The assays were then used to investigate two outbreaks of gastroenteritis in two Irish hospitals. 56 samples were screened for NoV using a real-time RT-PCR assay and 26 samples were found to be positive. Genotyping of these positive samples found that all positives belonged to the GII\\/4 variant of NoV. CONCLUSION: The combination of the Real-time assay and the reverse line blot hybridisation assay provided a fast and accurate method to investigate a NoV associated outbreak. It was concluded that the predominant genotype circulating in these Irish hospitals was GII\\/4 which has been associated with the majority of NoV outbreaks worldwide. The assays developed in this study are useful tools for investigating NoV infection.

  12. Daily life activity routine discovery in hemiparetic rehabilitation patients using topic models.

    Science.gov (United States)

    Seiter, J; Derungs, A; Schuster-Amft, C; Amft, O; Tröster, G

    2015-01-01

    Monitoring natural behavior and activity routines of hemiparetic rehabilitation patients across the day can provide valuable progress information for therapists and patients and contribute to an optimized rehabilitation process. In particular, continuous patient monitoring could add type, frequency and duration of daily life activity routines and hence complement standard clinical scores that are assessed for particular tasks only. Machine learning methods have been applied to infer activity routines from sensor data. However, supervised methods require activity annotations to build recognition models and thus require extensive patient supervision. Discovery methods, including topic models could provide patient routine information and deal with variability in activity and movement performance across patients. Topic models have been used to discover characteristic activity routine patterns of healthy individuals using activity primitives recognized from supervised sensor data. Yet, the applicability of topic models for hemiparetic rehabilitation patients and techniques to derive activity primitives without supervision needs to be addressed. We investigate, 1) whether a topic model-based activity routine discovery framework can infer activity routines of rehabilitation patients from wearable motion sensor data. 2) We compare the performance of our topic model-based activity routine discovery using rule-based and clustering-based activity vocabulary. We analyze the activity routine discovery in a dataset recorded with 11 hemiparetic rehabilitation patients during up to ten full recording days per individual in an ambulatory daycare rehabilitation center using wearable motion sensors attached to both wrists and the non-affected thigh. We introduce and compare rule-based and clustering-based activity vocabulary to process statistical and frequency acceleration features to activity words. Activity words were used for activity routine pattern discovery using topic models

  13. The clinical utility of the Cornell Scale for Depression in Dementia as a routine assessment in nursing homes.

    Science.gov (United States)

    Jeon, Yun-Hee; Li, Zhicheng; Low, Lee-Fay; Chenoweth, Lynn; O'Connor, Daniel; Beattie, Elizabeth; Liu, Zhixin; Brodaty, Henry

    2015-08-01

    To examine the clinical utility of the Cornell Scale for Depression in Dementia (CSDD) in nursing homes. 14 nursing homes in Sydney and Brisbane, Australia. 92 residents with a mean age of 85 years. Consenting residents were assessed by care staff for depression using the CSDD as part of their routine assessment. Specialist clinicians conducted assessment of depression using the Semi-structured Clinical Diagnostic Interview for DSM-IV-TR Axis I Disorders for residents without dementia or the Provisional Diagnostic Criteria for Depression in Alzheimer Disease for residents with dementia to establish expert clinical diagnoses of depression. The diagnostic performance of the staff completed CSDD was analyzed against expert diagnosis using receiver operating characteristic (ROC) curves. The CSDD showed low diagnostic accuracy, with areas under the ROC curve being 0.69, 0.68 and 0.70 for the total sample, residents with dementia and residents without dementia, respectively. At the standard CSDD cutoff score, the sensitivity and specificity were 71% and 59% for the total sample, 69% and 57% for residents with dementia, and 75% and 61% for residents without dementia. The Youden index (for optimizing cut-points) suggested different depression cutoff scores for residents with and without dementia. When administered by nursing home staff the clinical utility of the CSDD is highly questionable in identifying depression. The complexity of the scale, the time required for collecting relevant information, and staff skills and knowledge of assessing depression in older people must be considered when using the CSDD in nursing homes. Copyright © 2015 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  14. Unrequested information from routine diagnostic chest CT predicts future cardiovascular events

    International Nuclear Information System (INIS)

    Jacobs, Peter C.; Gondrie, Martijn J.; Grobbee, Diederick E.; Graaf, Yolanda van der; Mali, Willem P.; Oen, Ayke L.; Prokop, Mathias

    2011-01-01

    An increase in the number of CT investigations will likely result in a an increase in unrequested information. Clinical relevance of these findings is unknown. This is the first follow-up study to investigate the prognostic relevance of subclinical coronary (CAC) and aortic calcification (TAC) as contained in routine diagnostic chest CT in a clinical care population. The follow-up of 10,410 subjects (>40 years) from a multicentre, clinical care-based cohort of patients included 240 fatal to 275 non-fatal cardiovascular disease (CVD) events (mean follow-up 17.8 months). Patients with a history of CVD were excluded. Coronary (0-12) and aortic calcification (0-8) were semi-quantitatively scored. We used Cox proportional-hazard models to compute hazard ratios to predict CVD events. CAC and TAC were significantly and independently predictive of CVD events. Compared with subjects with no calcium, the adjusted risk of a CVD event was 3.7 times higher (95% CI, 2.7-5.2) among patients with severe coronary calcification (CAC score ≥6) and 2.7 times higher (95% CI, 2.0-3.7) among patients with severe aortic calcification (TAC score ≥5). Subclinical vascular calcification on CT is a strong predictor of incident CVD events in a routine clinical care population. (orig.)

  15. A novel and rapid microbiological assay for ciprofloxacin hydrochloride

    Directory of Open Access Journals (Sweden)

    Edith Cristina Laignier Cazedey

    2013-10-01

    Full Text Available The present work reports a simple, fast and sensitive microbiological assay applying the turbidimetric method for the determination of ciprofloxacin hydrochloride (CIPRO HCl in ophthalmic solutions. The validation method yielded good results and included excellent linearity, precision, accuracy and specificity. The bioassay is based on the inhibitory effect of CIPRO HCl upon the strain of Staphylococcus epidermidis ATCC 12228 used as the test microorganism. The results were treated statistically by analysis of variance (ANOVA and were found to be linear (r=0.9994, in the range of 14.0–56.0 µg/mL, precise (intraday RSD%=2.06; interday RSD%=2.30 and accurate (recovery=99.71%. The turbidimetric assay was compared to the UV spectrophotometric and HPLC methods for the same drug. The turbidimetric bioassay described on this paper for determination of ciprofloxacin hydrochloride in ophthalmic solution is an alternative to the physicochemical methods disclosed in the literature and can be used in quality control routine. Keywords: Antibiotics, Fluoroquinolones, Ciprofloxacin hydrochloride, Quality control, Microbiological assay, Turbidimetric method

  16. Islet Oxygen Consumption Rate (OCR) Dose Predicts Insulin Independence in Clinical Islet Autotransplantation.

    Science.gov (United States)

    Papas, Klearchos K; Bellin, Melena D; Sutherland, David E R; Suszynski, Thomas M; Kitzmann, Jennifer P; Avgoustiniatos, Efstathios S; Gruessner, Angelika C; Mueller, Kathryn R; Beilman, Gregory J; Balamurugan, Appakalai N; Loganathan, Gopalakrishnan; Colton, Clark K; Koulmanda, Maria; Weir, Gordon C; Wilhelm, Josh J; Qian, Dajun; Niland, Joyce C; Hering, Bernhard J

    2015-01-01

    Reliable in vitro islet quality assessment assays that can be performed routinely, prospectively, and are able to predict clinical transplant outcomes are needed. In this paper we present data on the utility of an assay based on cellular oxygen consumption rate (OCR) in predicting clinical islet autotransplant (IAT) insulin independence (II). IAT is an attractive model for evaluating characterization assays regarding their utility in predicting II due to an absence of confounding factors such as immune rejection and immunosuppressant toxicity. Membrane integrity staining (FDA/PI), OCR normalized to DNA (OCR/DNA), islet equivalent (IE) and OCR (viable IE) normalized to recipient body weight (IE dose and OCR dose), and OCR/DNA normalized to islet size index (ISI) were used to characterize autoislet preparations (n = 35). Correlation between pre-IAT islet product characteristics and II was determined using receiver operating characteristic analysis. Preparations that resulted in II had significantly higher OCR dose and IE dose (p<0.001). These islet characterization methods were highly correlated with II at 6-12 months post-IAT (area-under-the-curve (AUC) = 0.94 for IE dose and 0.96 for OCR dose). FDA/PI (AUC = 0.49) and OCR/DNA (AUC = 0.58) did not correlate with II. OCR/DNA/ISI may have some utility in predicting outcome (AUC = 0.72). Commonly used assays to determine whether a clinical islet preparation is of high quality prior to transplantation are greatly lacking in sensitivity and specificity. While IE dose is highly predictive, it does not take into account islet cell quality. OCR dose, which takes into consideration both islet cell quality and quantity, may enable a more accurate and prospective evaluation of clinical islet preparations.

  17. Islet Oxygen Consumption Rate (OCR Dose Predicts Insulin Independence in Clinical Islet Autotransplantation.

    Directory of Open Access Journals (Sweden)

    Klearchos K Papas

    Full Text Available Reliable in vitro islet quality assessment assays that can be performed routinely, prospectively, and are able to predict clinical transplant outcomes are needed. In this paper we present data on the utility of an assay based on cellular oxygen consumption rate (OCR in predicting clinical islet autotransplant (IAT insulin independence (II. IAT is an attractive model for evaluating characterization assays regarding their utility in predicting II due to an absence of confounding factors such as immune rejection and immunosuppressant toxicity.Membrane integrity staining (FDA/PI, OCR normalized to DNA (OCR/DNA, islet equivalent (IE and OCR (viable IE normalized to recipient body weight (IE dose and OCR dose, and OCR/DNA normalized to islet size index (ISI were used to characterize autoislet preparations (n = 35. Correlation between pre-IAT islet product characteristics and II was determined using receiver operating characteristic analysis.Preparations that resulted in II had significantly higher OCR dose and IE dose (p<0.001. These islet characterization methods were highly correlated with II at 6-12 months post-IAT (area-under-the-curve (AUC = 0.94 for IE dose and 0.96 for OCR dose. FDA/PI (AUC = 0.49 and OCR/DNA (AUC = 0.58 did not correlate with II. OCR/DNA/ISI may have some utility in predicting outcome (AUC = 0.72.Commonly used assays to determine whether a clinical islet preparation is of high quality prior to transplantation are greatly lacking in sensitivity and specificity. While IE dose is highly predictive, it does not take into account islet cell quality. OCR dose, which takes into consideration both islet cell quality and quantity, may enable a more accurate and prospective evaluation of clinical islet preparations.

  18. Clinical role of Ureaplasma parvum and Ureaplasma urealyticum presence in female lower urogenital tract: Is there a place for routine screening and treatment?

    Directory of Open Access Journals (Sweden)

    Maruška Marovt

    2014-10-01

    Full Text Available Sexually transmitted infections represent major health problem in females all over the world if remained undiagnosed and untreated. They can have adverse influence on reproduction and health of a mother and a newborn. The development of molecular methods has permitted the detection of an array of microbes whose pathologic roles in urogenital infections need to be further studied. Ureaplasmas (Ureaplasma spp., being originally found in 1954 from male urogenital tract, are prokaryotic cells without a cell wall, ranging from 0.1 to 1 μm in length. Fourteen known Ureaplasma serovars have been divided in two species based on their phenotypic and genotypic features, Ureaplasma parvum and Ureaplasma urealyticum detected and identified separately using polymerase chain reaction assays. Both are generally considered as genital tract commensals. U. urealyticum is most probably associated with male urethritis which has not been found for U. parvum. Recent studies with supposedly healthy women reported their detection rate between 18-87 % for U. parvum and 6-10 % for U. urealyticum. Even though they have been found to be associated with chorioamnionitis, preterm birth and perinatal complications more commonly then other commensals in this region the rising question regarding their pathogenic role in females remains unsolved and the guidelines regarding the diagnostic screening and treatment are inconsistent. The aim of our paper is to review the microbiological characteristics, diagnostic methods and epidemiology of newly differentiated U. parvum and U. urealyticum, and to assess evidence speaking pro and contra their clinical role in causing lower urogenital tract infection in women. Since both bacteria are susceptible to antimicrobials it is of utmost importance for clinicians to decide whether or not to search for one or both of them routinely and treat accordingly in order to prevent ascending upper genital tract infection as well as complications in

  19. Diagnostic accuracy of two multiplex real-time polymerase chain reaction assays for the diagnosis of meningitis in children in a resource-limited setting.

    Directory of Open Access Journals (Sweden)

    Jermaine Khumalo

    Full Text Available Accurate etiological diagnosis of meningitis is important, but difficult in resource-limited settings due to prior administration of antibiotics and lack of viral diagnostics. We aimed to develop and validate 2 real-time multiplex PCR (RT-PCR assays for the detection of common causes of community-acquired bacterial and viral meningitis in South African children.We developed 2 multiplex RT- PCRs for detection of S. pneumoniae, N. meningitidis, H. influenzae, enteroviruses, mumps virus and herpes simplex virus. We tested residual CSF samples from children presenting to a local paediatric hospital over a one-year period, whose CSF showed an abnormal cell count. Results were compared with routine diagnostic tests and the final discharge diagnosis. We calculated accuracy of the bacterial RT-PCR assay compared to CSF culture and using World Health Organisation definitions of laboratory-confirmed bacterial meningitis.From 292 samples, bacterial DNA was detected in 12 (4.1% and viral nucleic acids in 94 (32%. Compared to CSF culture, the sensitivity and specificity of the bacterial RT-PCR was 100% and 97.2% with complete agreement in organism identification. None of the cases positive by viral RT-PCR had a bacterial cause confirmed on CSF culture. Only 9/90 (10% of patients diagnosed clinically as bacterial meningitis or partially treated bacterial meningitis tested positive with the bacterial RT-PCR.In this population the use of 2 multiplex RT-PCRs targeting 6 common pathogens gave promising results. If introduced into routine diagnostic testing, these multiplex RT-PCR assays would supplement other diagnostic tests, and have the potential to limit unnecessary antibiotic therapy and hospitalisation.

  20. Transitioning couple's voluntary HIV counseling and testing (CVCT from stand-alone weekend services into routine antenatal and VCT services in government clinics in Zambia's two largest cities.

    Directory of Open Access Journals (Sweden)

    Mubiana Inambao

    Full Text Available Most HIV infections in Africa are acquired by married/cohabiting adults and WHO recommends couple's voluntary HIV counseling and testing (CVCT for prevention. The handover from NGO-sponsored weekend CVCT to government-sponsored services in routine weekday antenatal care (ANC and individual voluntary testing and counseling (VCT services in Zambia's two largest cities from 2009-2015 is described.Government clinic counselors were trained to provide CVCT, and along with community health workers they promoted CVCT services in their clinic and surrounding areas. When client volume exceeded the capacity of on-duty staff in ANC and VCT, non-governmental organization (NGO subsidies were offered for overtime pay.Implementation of routine CVCT services varied greatly by clinic and city. The 12 highest volume clinics were examined further, while 13 clinics had CVCT numbers that were too low to warrant further investigation. In Lusaka, the proportion of pregnant women whose partners were tested rose from 2.6% in 2009 to a peak of 26.2% in 2012 and 24.8% in 2015. Corresponding reports in Ndola were 2.0% in 2009, 17.0% in 2012 and 14.5% in 2015. Obstacles to CVCT included: limited space and staffing, competing priorities, record keeping not adapted for couples, and few resources for promotion and increasing male involvement. Conflicting training models for 'partner testing' with men and women separately vs. CVCT with joint post-test counseling led to confusion in reporting to district health authorities.A focused and sustained effort will be required to reach a meaningful number of couples with CVCT to prevent heterosexual and perinatal HIV transmission. Establishing targets and timelines, funding for dedicated and appropriately trained staff, adoption of standardized data recording instruments with couple-level indicators, and expansion of community and clinic-based promotions using proven models are recommended.

  1. Data format translation routines

    International Nuclear Information System (INIS)

    Burris, R.D.

    1981-02-01

    To enable the effective connection of several dissimilar computers into a network, modification of the data being passed from one computer to another may become necessary. This document describes a package of routines which permit the translation of data in PDP-8 formats to PDP-11 or DECsystem-10 formats or from PDP-11 format to DECsystem-10 format. Additional routines are described which permit the effective use of the translation routines in the environment of the Fusion Energy Division (FED) network and the Elmo Bumpy Torus (EBT) data base

  2. Routines and Organizational Change

    DEFF Research Database (Denmark)

    Yi, Sangyoon; Becker, Markus; Knudsen, Thorbjørn

    2014-01-01

    Routines have been perceived as a source of inertia in the process of organizational change. In this study, we suggest an overlooked, but prevalent, mechanism by which the inertial nature of routines helps, rather than hinders, organizational adaptation. Routine-level inertia plays a hidden role...... to cope with its task environment. In our nuanced perspective, inertia is not only a consequence of adaptation but also a source of adaptation. This logic is helpful to understand why reliable but apparently inertial organizations keep surviving and often exhibit outstanding performance. We conclude...

  3. Non-interventional (observational study of application of the tamsulosin (Proflosin® in patients with benign prostatic hyperplasia in routine clinical practice

    Directory of Open Access Journals (Sweden)

    L. G. Spivak

    2014-01-01

    Full Text Available The problem of therapy of benign prostatic hyperplasia has not lost its relevance today due to the high prevalence rate of this pathologyamong the male population. The article provides the results of non-interventional (observational study of application of the tamsulosin(Proflosin® drug or combined therapy with tamsulosin (Proflosin® + Serenoa repens (Prostamol® Uno of patients with benign prostatic hyperplasia in routine clinical practice. 1,000 practicing urology experts from 100 cities and towns of Russia took part in the study as well as 23 492 patients with the established diagnosis of benign prostatic hyperplasia, which were prescribed with tamsulosin (Proflosin® monotherapy or combined therapy with tamsulosin (Proflosin® + Serenoa repens (Prostamol® Uno in conditions of outpatient clinical practice. As a result of the study, improvement of the life standard and subjective symptoms were stated with patients with the absence of significant side effects directly associated with intake of the drug studies.

  4. Non-interventional (observational study of application of the tamsulosin (Proflosin® in patients with benign prostatic hyperplasia in routine clinical practice

    Directory of Open Access Journals (Sweden)

    L. G. Spivak

    2015-02-01

    Full Text Available The problem of therapy of benign prostatic hyperplasia has not lost its relevance today due to the high prevalence rate of this pathologyamong the male population. The article provides the results of non-interventional (observational study of application of the tamsulosin(Proflosin® drug or combined therapy with tamsulosin (Proflosin® + Serenoa repens (Prostamol® Uno of patients with benign prostatic hyperplasia in routine clinical practice. 1,000 practicing urology experts from 100 cities and towns of Russia took part in the study as well as 23 492 patients with the established diagnosis of benign prostatic hyperplasia, which were prescribed with tamsulosin (Proflosin® monotherapy or combined therapy with tamsulosin (Proflosin® + Serenoa repens (Prostamol® Uno in conditions of outpatient clinical practice. As a result of the study, improvement of the life standard and subjective symptoms were stated with patients with the absence of significant side effects directly associated with intake of the drug studies.

  5. Reproducibility Problems with the Abbott Laboratories LCx Assay for Chlamydia trachomatis and Neisseria gonorrhoeae

    OpenAIRE

    Gronowski, Ann M.; Copper, Susan; Baorto, David; Murray, Patrick R.

    2000-01-01

    This study demonstrates that significant reproducibility problems can occur during routine use of the Abbott Laboratories LCx assay for Chlamydia trachomatis and Neisseria gonorrhoeae. These problems can go undetected by the quality control procedures outlined in the manufacturer's package insert. We outline here procedures for detecting and preventing contamination and reproducibility problems.

  6. A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India.

    Science.gov (United States)

    Chandra, Praveen; Kumar, Tarun

    2014-01-01

    A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  7. Imaging tests in staging and surveillance of non-metastatic breast cancer: changes in routine clinical practice and cost implications.

    Science.gov (United States)

    De Placido, S; De Angelis, C; Giuliano, M; Pizzi, C; Ruocco, R; Perrone, V; Bruzzese, D; Tommasielli, G; De Laurentiis, M; Cammarota, S; Arpino, G; Arpino, G

    2017-03-14

    Although guidelines do not recommend computerised tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI) for the staging or follow-up of asymptomatic patients with non-metastatic breast cancer, they are often requested in routine clinical practice. The aim of this study was to determine the staging and follow-up patterns, and relative costs in a large population of breast cancer patients living and treated in a Southern Italian region. We analysed the clinical computerised information recorded by 567 primary-care physicians assisting about 650 000 inhabitants in the Campania region. Patients with non-metastatic breast cancer were identified and divided into calendar years from 2001 to 2010. The number of diagnostic tests prescribed per 100 patients (N/Pts) and the mean cost per patient was determined 3 months before diagnosis and up to 1 year after diagnosis. Costs are expressed in constant 2011 euros. We identified 4680 newly diagnosed cases of asymptomatic non-metastatic breast cancer. N/Pts increased significantly (Ptests'), and costs was unchanged. However, the number of CT, PET scans and MRI ('new tests')prescriptions almost quadrupled and the mean cost per patient related to these procedures significantly increased from [euro ]357 in 2001 to [euro ]830 in 2010 (Ptest prescriptions and relative costs significantly and steadily increased throughout the study period. At present there is no evidence that the delivery of new tests to asymptomatic patients improves breast cancer outcome. Well-designed clinical trials are urgently needed to shed light on the impact of these tests on clinical outcome and overall survival.

  8. The potential of high resolution melting analysis (hrma) to streamline, facilitate and enrich routine diagnostics in medical microbiology.

    Science.gov (United States)

    Ruskova, Lenka; Raclavsky, Vladislav

    2011-09-01

    Routine medical microbiology diagnostics relies on conventional cultivation followed by phenotypic techniques for identification of pathogenic bacteria and fungi. This is not only due to tradition and economy but also because it provides pure culture needed for antibiotic susceptibility testing. This review focuses on the potential of High Resolution Melting Analysis (HRMA) of double-stranded DNA for future routine medical microbiology. Search of MEDLINE database for publications showing the advantages of HRMA in routine medical microbiology for identification, strain typing and further characterization of pathogenic bacteria and fungi in particular. The results show increasing numbers of newly-developed and more tailor-made assays in this field. For microbiologists unfamiliar with technical aspects of HRMA, we also provide insight into the technique from the perspective of microbial characterization. We can anticipate that the routine availability of HRMA in medical microbiology laboratories will provide a strong stimulus to this field. This is already envisioned by the growing number of medical microbiology applications published recently. The speed, power, convenience and cost effectiveness of this technology virtually predestine that it will advance genetic characterization of microbes and streamline, facilitate and enrich diagnostics in routine medical microbiology without interfering with the proven advantages of conventional cultivation.

  9. 21 CFR 866.3210 - Endotoxin assay.

    Science.gov (United States)

    2010-04-01

    ... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3210 Endotoxin assay. (a... intended for use in conjunction with other laboratory findings and clinical assessment of the patient to...

  10. Evaluation of the Sepsis Flow Chip assay for the diagnosis of blood infections.

    Science.gov (United States)

    Galiana, Antonio; Coy, Javier; Gimeno, Adelina; Guzman, Noemi Marco; Rosales, Francisco; Merino, Esperanza; Royo, Gloria; Rodríguez, Juan Carlos

    2017-01-01

    Blood infections are serious complex conditions that generally require rapid diagnosis and treatment. The big challenge is to reduce the time necessary to make a diagnosis with current clinical microbiological methods so as to improve the treatment given to patients. In this study, we assess for the first time the Sepsis Flow Chip assay, which is a novel diagnostic assay for simultaneous rapid-detection of the vast majority of bloodstream pathogens, including Gram-positive and Gram-negative bacteria and fungi, in the same assay, and for the detection of most common antibiotic resistance genes. The SFC assay is based on multiplex PCR and low density DNA arrays. Positive blood cultures from 202 consecutive bacteremia patients were analyzed by SFC assay and the results were compared with the results obtained by the gold standard methodology used in clinical microbiology diagnostic laboratories (EUCAST guidelines). SFC assay overall sensitivity and specificity for bacterial identification were 93.3% and 100% respectively and sensitivity and specificity for the identification of antibiotic genetic resistance determinants were 93.6% and 100% respectively. This is the first evaluation of SFC assay in clinical samples. This new method appears to be very promising by combining the high number of distinct pathogens and genetic resistance determinants identified in a single assay. Further investigations should be done to evaluate the usefulness of this assay in combination with clinical multidisciplinary groups (stewardship), in order for the results to be applied appropriately to the management of patients`infectious processes.

  11. Effects of introducing routinely ultrasound scanning during Ante Natal Care (ANC) clinics on number of visits of ANC and facility delivery: a cohort study.

    Science.gov (United States)

    Mbuyita, Selemani; Tillya, Robert; Godfrey, Ritha; Kinyonge, Iddajovana; Shaban, Josephine; Mbaruku, Godfrey

    2015-01-01

    Many countries have integrated antenatal care as an essential part of routine maternal health services. The importance of this service cannot be overemphasized as many women's lives are usually saved particularly through early detection of pregnancy related complications. However, while many women would attend at least one visit for ante natal care (ANC), completion of recommended number of visits (4+) has been a challenge of many health systems particularly in developing countries like Tanzania. We conducted a cohort study to include ultrasound scanning using a portable hand-held Vscan to test whether by integrating it in routine ANC clinics at dispensary and health centre levels would promote number of ANC visits by women. Health providers rendering ANC services in selected facilities were trained on how to use the simple technology of ultrasound scanning. Women living in catchment areas of the respective selected facilities were eligible to inclusion to the study when consented. A baseline status of the ANC attendance in the study area was established through baseline household and facility surveys. A total of 257 women consented and received the study treatment. Our results showed that, there was no a slight change between baseline (97.2 %) and endline (97.4 %) results among women attending ANC clinics at least once. However, there was a significant change in percentage of women attending ANC clinic four times or more (27.2 % during baseline and 60.3 %; p = 0001). We conclude that, introduction of the simplified ultrasound scanning technology at lowest levels of care has an effect to improving ANC attendance in terms of number of visits and motivate facility delivery.

  12. Clinical impact of predictive assays for acute and late radiation morbidity

    International Nuclear Information System (INIS)

    Budach, W.; Classen, J.; Belka, C.; Bamberg, M.

    1998-01-01

    Background: Clinically reliable predictive assays for normal tissue radiation sensitivity would help to avoid severe radiation induced morbidity and result in individualized dose prescriptions. Profound differences of individual fibroblast and lymphocyte radiation sensitivity in vitro have been documented in patients with certain genetic syndromes but also in patients without known genetic disorders. The following review evaluates whether fibroblast or lymphocyte radiation sensitivity measured in vitro correlates with the degree of acute and late radiation induced morbidity. Results: Acute radiation side effects and lymphocyte sensitivity has been investigated in 2 studies. One of them reported an insecure correlation, the other no correlation at all. Fibroblast radiation sensitivity and the extent of acute radiation induced side effects on skin and mucosal sites has been compared in a total of 5 studies. None of these studies found a consistent significant correlation. Lymphocyte radiation sensitivity and late effects have been studied by 2 institutions. Late radiation induced skin and mucosal changes did not correlate with lymphocyte sensitivity in head and neck cancer patients, whereas in breast cancer patients a weak (R 2 =0.06) correlation between the degree of late skin reactions and lymphocyte sensitivity was observed. Late skin or mucosal radiation reactions and fibroblast sensitivity were examined by 5 research groups. Data analysis revealed significant correlations or at least a trend towards a significant correlation in all studies. The quality of the reported correlations expressed as R 2 ranged from 0.13 to 0.60, indicating a low predictive value. Conclusions: Lymphocyte radiation sensitivity as measured by currently available assays does not or only poorly correlate with acute and late effects of radiation in patients, precluding predictive tests based on lymphocyte sensitivity. Fibroblast radiation sensitivity does not correlate with acute but

  13. Serum HER-2 concentrations for monitoring women with breast cancer in a routine oncology setting

    DEFF Research Database (Denmark)

    Sørensen, Patricia Diana; Jakobsen, Erik Hugger; Langkjer, Sven Tyge

    2009-01-01

    BACKGROUND: The purpose of this study was to determine the positive predictive value (PPV) of positive serum human epidermal growth factor receptor-2 (HER-2) for monitoring women with breast cancer following diagnosis and treatment in a routine clinical setting. METHODS: Serum HER-2 was measured...... could be determined in ten tissue-positive patients was 3-24 months (mean 11.3 months), when compared to standard clinical imaging methods. CONCLUSIONS: Serum HER-2 is a useful marker for the detection of recurrence of breast cancer and for monitoring the effect of treatment, especially in tissue HER-2...... in 1348 patients with breast cancer: 837 during routine oncology clinic visits and 511 following new diagnosis. All patients with positive serum HER-2, 1/5 of negative patients from the oncology clinic, and all the newly diagnosed were followed; a total of 862 patients. Serum HER-2 was measured using...

  14. Is Transducer Hygiene sufficient when Vaginal Probes are used in the Clinical Routine?

    Science.gov (United States)

    Merz, E

    2016-04-01

    Vaginal ultrasound probes are semi-critical Group A medical products which must be disinfected following the manufacturer's instructions after every patient examination. According to the "Essential Requirements for Medical Devices (Directive 93/42/EEC, Annex I, paragraph 13)" the manufacturer's instructions for use for reusable products must contain suitable instructions for preparation processes. This presumes both an effective and material-compatible method. Evidence of effectiveness must be validated.In the Editorial in issue 1 Ultraschall in der Medizin/European Journal of Ultrasound 2005 we discussed the topic of transducer hygiene and stated that proper handling and cleaning as well as disinfection of probes in daily use are indispensable. This applies particularly to vaginal ultrasound probes routinely used in gynecological and obstetrical clinics, gynecological practices as well as IVF centers Normally the probe used in a transvaginal ultrasound examination is covered with a latex protective cover (with CE marking) which contains a certain amount of ultrasound gel. After the examination, the cover is removed and disposed of, and the gel is removed from the transducer. Since handling of the probe, ultrasound gel and cover can result in smear infections and cross-contamination with various pathogens (e. g. MRSA, HBV, HCV, HIV, herpes papilloma and cytomegalic viruses), after the protective cover is removed, the probe must be cleaned and subjected to disinfection with a bactericidal, fungicidal and virucidal effect. This is especially important in the event the cover ruptures during the vaginal examination, and the probe comes into direct contact with vaginal secretions or blood. The same likewise applies if the sterile protective cover is perforated during a follicular puncture. Usually special bactericidal, levurocidal and virucidal wipes or special submersion disinfection methods are available for disinfecting the vaginal ultrasound probes 11. Using

  15. Evaluation of macrocytosis in routine hemograms.

    Science.gov (United States)

    Veda, P

    2013-03-01

    Macrocytosis, a condition in which erythrocytes are larger than normal manifests as an increase in mean corpuscular volume (MCV) more than 100 fl. The aim of this study was to identify the underlying causes of macrocytosis, detected in routine hemograms and to evaluate the hematological features in different etiologies. This study included 178 adult patients whose detailed medical history was recorded, and Vitamin B12 assay, folate assay, thyroid function tests, liver function tests, complete blood counts and peripheral smear evaluation was performed. Alcoholism was identified as the etiological factor in 65 cases (36.5%), Vitamin B12 deficiency in 43 cases (24.1%) and drug related in 23 cases (12.9%). These three conditions accounted for 73.6% of macrocytosis. Other causes identified were folate deficiency, liver disease, Myelodysplastic syndrome, chronic renal failure and Aplastic anemia. In 41 cases, the cause of macrocytosis could not be explained. Anemia was observed in 95 cases (53.3%) being most common in Vitamin B12 deficiency. 9 cases (20.9%) of Vitamin B12 deficiency presented with isolated macrocytosis without anemia. It was observed that mean hemoglobin was lower and red cell distribution width (RDW) higher in megaloblastic conditions. Peripheral smear revealed hypersegmented neutrophils in 86% and macro-ovalocytes in 72% of the megaloblastic cases. Complete medical history, red cell parameters and peripheral blood smear are simple, inexpensive tools which assist in identifying the underlying cause of macrocytosis, particularly in resource limited settings. Macrocytosis needs to be evaluated even in the absence of anemia, as it may be the first clue to an underlying pathology.

  16. Novel Molecular Beacon Probe-Based Real-Time RT-PCR Assay for Diagnosis of Crimean-Congo Hemorrhagic Fever Encountered in India

    Directory of Open Access Journals (Sweden)

    Aman Kamboj

    2014-01-01

    Full Text Available Crimean-Congo hemorrhagic fever (CCHF is an emerging zoonotic disease in India and requires immediate detection of infection both for preventing further transmission and for controlling the infection. The present study describes development, optimization, and evaluation of a novel molecular beacon-based real-time RT-PCR assay for rapid, sensitive, and specific diagnosis of Crimean-Congo hemorrhagic fever virus (CCHFV. The developed assay was found to be a better alternative to the reported TaqMan assay for routine diagnosis of CCHF.

  17. Emerging Technologies and Generic Assays for the Detection of Anti-Drug Antibodies

    Directory of Open Access Journals (Sweden)

    Michael A. Partridge

    2016-01-01

    Full Text Available Anti-drug antibodies induced by biologic therapeutics often impact drug pharmacokinetics, pharmacodynamics response, clinical efficacy, and patient safety. It is critical to assess the immunogenicity risk of potential biotherapeutics in producing neutralizing and nonneutralizing anti-drug antibodies, especially in clinical phases of drug development. Different assay methodologies have been used to detect all anti-drug antibodies, including ELISA, radioimmunoassay, surface plasmon resonance, and electrochemiluminescence-based technologies. The most commonly used method is a bridging assay, performed in an ELISA or on the Meso Scale Discovery platform. In this report, we aim to review the emerging new assay technologies that can complement or address challenges associated with the bridging assay format in screening and confirmation of ADAs. We also summarize generic anti-drug antibody assays that do not require drug-specific reagents for nonclinical studies. These generic assays significantly reduce assay development efforts and, therefore, shorten the assay readiness timeline.

  18. An optimized one-tube, semi-nested PCR assay for Paracoccidioides brasiliensis detection.

    Science.gov (United States)

    Pitz, Amanda de Faveri; Koishi, Andrea Cristine; Tavares, Eliandro Reis; Andrade, Fábio Goulart de; Loth, Eduardo Alexandre; Gandra, Rinaldo Ferreira; Venancio, Emerson José

    2013-01-01

    Herein, we report a one-tube, semi-nested-polymerase chain reaction (OTsn-PCR) assay for the detection of Paracoccidioides brasiliensis. We developed the OTsn-PCR assay for the detection of P. brasiliensis in clinical specimens and compared it with other PCR methods. The OTsn-PCR assay was positive for all clinical samples, and the detection limit was better or equivalent to the other nested or semi-nested PCR methods for P. brasiliensis detection. The OTsn-PCR assay described in this paper has a detection limit similar to other reactions for the molecular detection of P. brasiliensis, but this approach is faster and less prone to contamination than other conventional nested or semi-nested PCR assays.

  19. Exploring physical and chemical factors influencing the properties of recombinant prion protein and the real-time quaking-induced conversion (RT-QuIC) assay.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David

    2014-01-01

    Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.

  20. Organizational routines, innovation, and flexibility: the application of narrative networks to dynamic workflow.

    Science.gov (United States)

    Hayes, Gillian R; Lee, Charlotte P; Dourish, Paul

    2011-08-01

    The purpose of this paper is to demonstrate how current visual representations of organizational and technological processes do not fully account for the variability present in everyday practices. We further demonstrate how narrative networks can augment these representations to indicate potential areas for successful or problematic adoption of new technologies and potential needs for additional training. We conducted a qualitative study of the processes and routines at a major academic medical center slated to be supported by the development and installation of a new comprehensive HIT system. We used qualitative data collection techniques including observations of the activities to be supported by the new system and interviews with department heads, researchers, and both clinical and non-clinical staff. We conducted a narrative network analysis of these data by choosing exemplar processes to be modeled, selecting and analyzing narrative fragments, and developing visual representations of the interconnection of these narratives. Narrative networks enable us to view the variety of ways work has been and can be performed in practice, influencing our ability to design for innovation in use. Narrative networks are a means for analyzing and visualizing organizational routines in concert with more traditional requirements engineering, workflow modeling, and quality improvement outcome measurement. This type of analysis can support a deeper and more nuanced understanding of how and why certain routines continue to exist, change, or stop entirely. At the same time, it can illuminate areas in which adoption may be slow, more training or communication may be needed, and routines preferred by the leadership are subverted by routines preferred by the staff. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Utility of multispectral imaging for nuclear classification of routine clinical histopathology imagery

    Directory of Open Access Journals (Sweden)

    Harvey Neal R

    2007-07-01

    Full Text Available Abstract Background We present an analysis of the utility of multispectral versus standard RGB imagery for routine H&E stained histopathology images, in particular for pixel-level classification of nuclei. Our multispectral imagery has 29 spectral bands, spaced 10 nm within the visual range of 420–700 nm. It has been hypothesized that the additional spectral bands contain further information useful for classification as compared to the 3 standard bands of RGB imagery. We present analyses of our data designed to test this hypothesis. Results For classification using all available image bands, we find the best performance (equal tradeoff between detection rate and false alarm rate is obtained from either the multispectral or our "ccd" RGB imagery, with an overall increase in performance of 0.79% compared to the next best performing image type. For classification using single image bands, the single best multispectral band (in the red portion of the spectrum gave a performance increase of 0.57%, compared to performance of the single best RGB band (red. Additionally, red bands had the highest coefficients/preference in our classifiers. Principal components analysis of the multispectral imagery indicates only two significant image bands, which is not surprising given the presence of two stains. Conclusion Our results indicate that multispectral imagery for routine H&E stained histopathology provides minimal additional spectral information for a pixel-level nuclear classification task than would standard RGB imagery.

  2. Development of a Species-Specific PCR Assay for Detection of Leishmania donovani in Clinical Samples from Patients with Kala-Azar and Post-Kala-Azar Dermal Leishmaniasis

    Science.gov (United States)

    Salotra, Poonam; Sreenivas, G.; Pogue, Gregory P.; Lee, Nancy; Nakhasi, Hira L.; Ramesh, V.; Negi, N. S.

    2001-01-01

    We have developed a PCR assay that is capable of amplifying kinetoplast DNA (kDNA) of Leishmania donovani in a species-specific manner among Old World leishmanias. With Indian strains and isolates of L. donovani the assay was sensitive enough to detect kDNA in an amount equivalent to a single parasite or less. The extreme sensitivity of the assay was reflected in its ability to detect parasite DNA from small volumes of peripheral blood of patients with kala-azar (KA) and from skin lesions from patients with post-KA dermal leishmaniasis (PKDL). A total of 107 clinical leishmaniasis samples were analyzed. Of these 102 (95.3%) were positive by PCR. The test provided a diagnosis of KA with 96% sensitivity using patient whole-blood samples instead of bone marrow or spleen aspirates that are obtained by invasive procedures. The assay was also successful in the diagnosis of 45 of 48 PKDL cases (93.8%). Cross-reactions with pathogens prevalent in the area of endemicity, viz., Mycobacterium tuberculosis, Mycobacterium leprae, and Plasmodium spp., could be ruled out. Eighty-one control samples, including dermal scrapings from healthy portions of skin from patients with PKDL were all negative. Two of twenty controls from the area of endemicity were found positive by PCR assay; however, there was a good possibility that these two were asymptomatic carriers since they were serologically positive for KA. Thus, this PCR assay represents a tool for the diagnosis of KA and PKDL in Indian patients in a noninvasive manner, with simultaneous species identification of parasites in clinical samples. PMID:11230394

  3. Radioimmunoassays of parathyroid hormone: Clinical value of the midregion and c-terminal assay

    International Nuclear Information System (INIS)

    Hengst, K.; Raidt, H.; Hoegemann, B.; Wagner, H.

    1984-01-01

    PTH was measured by midregion and carboxy-terminal assay in 20 patients suffering from primary hyperparathyroidism, 30 patients with secondary hyperparathyroidism, 10 persons with tertiary hyperparathyroidism, 50 patients who underwent transplantation of the kidney, 10 patients with hypoparathyroidism and 10 patients with other hypocalcemia as well as in 50 normal persons. Diagnosing hyperparathyroidism both assays were successful, when serum kreatinine was within the normal range. Especially midregion fragments became elevated, when serum kreatinine was above 2,0 mg. During renal failure diagnosis of hyperparathyroidism and hypoparathyroidism is more difficult. In normal renal function, however, the midregion assay is more sensitive for diagnosis of hypoparathyroidism compared to the carboxy-terminal assay. After kidney transplantation midregion levels of PTH are elevated, perhaps because of a failure of the transplanted kidney to eliminate the midregion fragment. (orig.) [de

  4. The Single-Molecule Centroid Localization Algorithm Improves the Accuracy of Fluorescence Binding Assays.

    Science.gov (United States)

    Hua, Boyang; Wang, Yanbo; Park, Seongjin; Han, Kyu Young; Singh, Digvijay; Kim, Jin H; Cheng, Wei; Ha, Taekjip

    2018-03-13

    Here, we demonstrate that the use of the single-molecule centroid localization algorithm can improve the accuracy of fluorescence binding assays. Two major artifacts in this type of assay, i.e., nonspecific binding events and optically overlapping receptors, can be detected and corrected during analysis. The effectiveness of our method was confirmed by measuring two weak biomolecular interactions, the interaction between the B1 domain of streptococcal protein G and immunoglobulin G and the interaction between double-stranded DNA and the Cas9-RNA complex with limited sequence matches. This analysis routine requires little modification to common experimental protocols, making it readily applicable to existing data and future experiments.

  5. Building Data-Driven Pathways From Routinely Collected Hospital Data: A Case Study on Prostate Cancer

    Science.gov (United States)

    Clark, Jeremy; Cooper, Colin S; Mills, Robert; Rayward-Smith, Victor J; de la Iglesia, Beatriz

    2015-01-01

    Background Routinely collected data in hospitals is complex, typically heterogeneous, and scattered across multiple Hospital Information Systems (HIS). This big data, created as a byproduct of health care activities, has the potential to provide a better understanding of diseases, unearth hidden patterns, and improve services and cost. The extent and uses of such data rely on its quality, which is not consistently checked, nor fully understood. Nevertheless, using routine data for the construction of data-driven clinical pathways, describing processes and trends, is a key topic receiving increasing attention in the literature. Traditional algorithms do not cope well with unstructured processes or data, and do not produce clinically meaningful visualizations. Supporting systems that provide additional information, context, and quality assurance inspection are needed. Objective The objective of the study is to explore how routine hospital data can be used to develop data-driven pathways that describe the journeys that patients take through care, and their potential uses in biomedical research; it proposes a framework for the construction, quality assessment, and visualization of patient pathways for clinical studies and decision support using a case study on prostate cancer. Methods Data pertaining to prostate cancer patients were extracted from a large UK hospital from eight different HIS, validated, and complemented with information from the local cancer registry. Data-driven pathways were built for each of the 1904 patients and an expert knowledge base, containing rules on the prostate cancer biomarker, was used to assess the completeness and utility of the pathways for a specific clinical study. Software components were built to provide meaningful visualizations for the constructed pathways. Results The proposed framework and pathway formalism enable the summarization, visualization, and querying of complex patient-centric clinical information, as well as the

  6. Pitfalls in lung cancer molecular pathology: how to limit them in routine practice?

    Science.gov (United States)

    Ilie, M; Hofman, P

    2012-01-01

    New treatment options in advanced non-small cell lung carcinoma (NSCLC) targeting activating epidermal growth factor receptor (EGFR) gene mutations and other genetic alterations demonstrated the clinical significance of the molecular features of specific subsets of tumors. Therefore, the development of personalized medicine has stimulated the routine integration into pathology departments of somatic mutation testing. However, clinical mutation testing must be optimized and standardized with regard to histological profile, type of samples, pre-analytical steps, methodology and result reporting. Routine molecular testing in NSCLC is currently moving beyond EGFR mutational analysis. Recent progress of targeted therapies will require molecular testing for a wide panel of mutations for a personalized molecular diagnosis. As a consequence, efficient testing of multiple molecular abnormalities is an urgent requirement in thoracic oncology. Moreover, increasingly limited tumor sample becomes a major challenge for molecular pathology. Continuous efforts should be made for safe, effective and specific molecular analyses. This must be based on close collaboration between the departments involved in the management of lung cancer. In this review we explored the practical issues and pitfalls surrounding the routine implementation of molecular testing in NSCLC in a pathology laboratory.

  7. Evaluation of the Sepsis Flow Chip assay for the diagnosis of blood infections.

    Directory of Open Access Journals (Sweden)

    Antonio Galiana

    Full Text Available Blood infections are serious complex conditions that generally require rapid diagnosis and treatment. The big challenge is to reduce the time necessary to make a diagnosis with current clinical microbiological methods so as to improve the treatment given to patients.In this study, we assess for the first time the Sepsis Flow Chip assay, which is a novel diagnostic assay for simultaneous rapid-detection of the vast majority of bloodstream pathogens, including Gram-positive and Gram-negative bacteria and fungi, in the same assay, and for the detection of most common antibiotic resistance genes. The SFC assay is based on multiplex PCR and low density DNA arrays.Positive blood cultures from 202 consecutive bacteremia patients were analyzed by SFC assay and the results were compared with the results obtained by the gold standard methodology used in clinical microbiology diagnostic laboratories (EUCAST guidelines. SFC assay overall sensitivity and specificity for bacterial identification were 93.3% and 100% respectively and sensitivity and specificity for the identification of antibiotic genetic resistance determinants were 93.6% and 100% respectively.This is the first evaluation of SFC assay in clinical samples. This new method appears to be very promising by combining the high number of distinct pathogens and genetic resistance determinants identified in a single assay. Further investigations should be done to evaluate the usefulness of this assay in combination with clinical multidisciplinary groups (stewardship, in order for the results to be applied appropriately to the management of patients`infectious processes.

  8. Increased Exposure to Rigid Routines Can Lead to Increased Challenging Behavior Following Changes to Those Routines

    Science.gov (United States)

    Bull, Leah E.; Oliver, Chris; Callaghan, Eleanor; Woodcock, Kate A.

    2015-01-01

    Several neurodevelopmental disorders are associated with preference for routine and challenging behavior following changes to routines. We examine individuals with Prader-Willi syndrome, who show elevated levels of this behavior, to better understand how previous experience of a routine can affect challenging behavior elicited by disruption to…

  9. Reference cells and ploidy in the comet assay

    Directory of Open Access Journals (Sweden)

    Gunnar eBrunborg

    2015-02-01

    Full Text Available In the comet assay, single cells are analyzed with respect to their level of DNA damage. Discrimination of the individual cell or cell type based on DNA content, with concomitant scoring of the DNA damage, is useful since this may allow analysis of mixtures of cells. Different cells can then be characterized based on their ploidy, cell cycle stage, or genome size. We here describe two applications of such a cell type-specific comet assay: (i Testicular cell suspensions, analyzed on the basis of their ploidy during spermatogenesis; and (ii reference cells in the form of fish erythrocytes which can be included as internal standards to correct for inter-assay variations. With standard fluorochromes used in the comet assay, the total staining signal from each cell – whether damaged or undamaged – was found to be associated with the cell’s DNA content. Analysis of the fluorescence intensity of single cells is straightforward since these data are available in scoring systems based on image analysis. The analysis of testicular cell suspensions provides information on cell type specific composition, susceptibility to genotoxicants, and DNA repair. Internal reference cells, either untreated or carrying defined numbers of lesions induced by ionizing radiation, are useful for investigation of experimental factors that can cause variation in comet assay results, and for routine inclusion in experiments to facilitate standardization of methods and comparison of comet assay data obtained in different experiments or in different laboratories. They can also be used - in combination with a reference curve - to quantify the DNA lesions induced by a certain treatment. Fish cells of a range of genome sizes, both greater and smaller than human, are suitable for this purpose and they are inexpensive.

  10. Comparison between dot-immunoblotting assay and clinical sign determination method for quantifying avian infectious bronchitis virus vaccine by titration in embryonated eggs.

    Science.gov (United States)

    Yuk, Seong-Su; Kwon, Jung-Hoon; Noh, Jin-Yong; Hong, Woo-Tack; Gwon, Gyeong-Bin; Jeong, Jei-Hyun; Jeong, Sol; Youn, Ha-Na; Heo, Yong-Hwan; Lee, Joong-Bok; Park, Seung-Yong; Choi, In-Soo; Song, Chang-Seon

    2016-04-01

    A sensitive and specific method for measuring the vaccine titer of infectious bronchitis virus (IBV) is important to commercial manufacturers for improving vaccine quality. Typically, IBV is titrated in embryonated chicken eggs, and the infectivity of the virus dilutions is determined by assessing clinical signs in the embryos as evidence of viral propagation. In this study, we used a dot-immunoblotting assay (DIA) to measure the titers of IBV vaccines that originated from different pathogenic strains or attenuation methods in embryonated eggs, and we compared this assay to the currently used method, clinical sign evaluation. To compare the two methods, we used real-time reverse transcription-PCR, which had the lowest limit of detection for propagated IBV. As a clinical sign of infection, dwarfism of the embryo was quantified using the embryo: egg (EE) index. The DIA showed 9.41% higher sensitivity and 15.5% higher specificity than the clinical sign determination method. The DIA was particularly useful for measuring the titer of IBV vaccine that did not cause apparent stunting but propagated in embryonated chicken eggs such as a heat-adapted vaccine strain. The results of this study indicate that the DIA is a rapid, sensitive, reliable method for determining IBV vaccine titer in embryonated eggs at a relatively low cost. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A precise, efficient radiometric assay for bacterial growth

    International Nuclear Information System (INIS)

    Boonkitticharoen, V.; Ehrhardt, C.; Kirchner, P.T.

    1984-01-01

    The two-compartment radiometric assay for bacterial growth promised major advantages over systems in clinical use, but poor reproducibility and counting efficiency limited its application. In this method, 14-CO/sub 2/ produced by bacterial metabolism of C-14-glucose is trapped and counted on filter paper impregnated with NaOH and fluors. The authors sought to improve assay efficiency and precision through a systematic study of relevant physical and chemical factors. Improvements in efficiency (88% vs. 10%) and in precision (relative S.D. 5% vs. 40%) were produced by a) reversing growth medium and scintillator chambers to permit vigorous agitation, b) increasing NaOH quantity and using a supersaturated PPO solution and c) adding detergent to improve uniformity of NaOH-PPO mixture. Inoculum size, substrate concentration and O/sub 2/ transfer rate affected assay sensitivity but not bacterial growth rate. The authors' assay reliably detects bacterial growth for inocula of 10,000 organisms in 1 hour and for 25 organisms within 4 1/2 hours, thus surpassing other existing clinical and research methods

  12. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Wook; Lee, Heon Young [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    1995-06-15

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  13. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Heon Young

    1995-01-01

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  14. Routine reporting of estimated glomerular filtration rate (eGFR) in African laboratories and the need for its increased utilisation in clinical practice.

    Science.gov (United States)

    Adebisi, Simeon A

    2013-03-01

    Chronic Kidney Disease (CKD) is defined as the presence of markers of kidney damage or of estimated glomerular filtration rate (eGFR)clinical practice. Current guidelines advocate the use of prediction equations, such as the Cockcroft-Gault (CG) formula and the Modification of Diet in Renal Disease (MDRD) study-derived equations. Laboratories in African should commence routine reporting of eGFR for a number of reasons; 1. The sensitivity of serum creatinine (Scr) in identifying CKD is low.2. In Nigeria, a representative country; screening for Chronic Kidney Disease (CKD) is hardly considered in the routine practice of the primary and secondary care medical officers.3 Studies have shown that routine reporting of eGFR improved the documentation and identification of CKD by almost 50%.4 There is the possibility of reversing CKD if picked earlier.5. The high cost of treating CKD patients in advanced stages and the low per capital income status of the populace in Sub-Saharan Africa.6. Poor health infrastructure to manage advanced CKD patients in the continent.7. Several studies, now show lack of awareness of CKD among non-nephrologists that is related, at least in part, to difficulty in interpreting serum creatinine concentrations (the reciprocal, non-linear relationship between GFR and serum creatinine).8 Mathematical estimates of GFR [ as in eGFR] that incorporate creatinine concentration, as well as factors affecting creatinine production rates, such as size, gender, age and ethnic background, are more sensitive to changes in renal function than serum creatinine value alone.9 Recent guidelines define "action plans" for CKD according to the GFR, including referral to nephrologists at GFRs<30 mL.min(-1).(1.73 m2).

  15. An optimized one-tube, semi-nested PCR assay for Paracoccidioides brasiliensis detection

    Directory of Open Access Journals (Sweden)

    Amanda de Faveri Pitz

    2013-12-01

    Full Text Available Introduction Herein, we report a one-tube, semi-nested-polymerase chain reaction (OTsn-PCR assay for the detection of Paracoccidioides brasiliensis. Methods We developed the OTsn-PCR assay for the detection of P. brasiliensis in clinical specimens and compared it with other PCR methods. Results The OTsn-PCR assay was positive for all clinical samples, and the detection limit was better or equivalent to the other nested or semi-nested PCR methods for P. brasiliensis detection. Conclusions The OTsn-PCR assay described in this paper has a detection limit similar to other reactions for the molecular detection of P. brasiliensis, but this approach is faster and less prone to contamination than other conventional nested or semi-nested PCR assays.

  16. Effectiveness of core stabilization exercises and routine exercise therapy in management of pain in chronic non-specific low back pain: A randomized controlled clinical trial.

    Science.gov (United States)

    Akhtar, Muhammad Waseem; Karimi, Hossein; Gilani, Syed Amir

    2017-01-01

    Low back pain is a frequent problem faced by the majority of people at some point in their lifetime. Exercise therapy has been advocated an effective treatment for chronic low back pain. However, there is lack of consensus on the best exercise treatment and numerous studies are underway. Conclusive studies are lacking especially in this part of the world. Thisstudy was designed to compare the effectiveness of specific stabilization exercises with routine physical therapy exerciseprovided in patients with nonspecific chronic mechanical low back pain. This is single blinded randomized control trial that was conducted at the department of physical therapy Orthopedic and Spine Institute, Johar Town, Lahore in which 120 subjects with nonspecific chronic low back pain participated. Subjects with the age between 20 to 60 years and primary complaint of chronic low back pain were recruited after giving an informed consent. Participants were randomly assigned to two treatment groups A & B which were treated with core stabilization exercise and routine physical therapy exercise respectively. TENS and ultrasound were given as therapeutic modalities to both treatment groups. Outcomes of the treatment were recorded using Visual Analogue Scale (VAS) pretreatment, at 2 nd , 4 th and 6 th week post treatment. The results of this study illustrate that clinical and therapeutic effects of core stabilization exercise program over the period of six weeks are more effective in terms of reduction in pain, compared to routine physical therapy exercise for similar duration. This study found significant reduction in pain across the two groups at 2 nd , 4 th and 6 th week of treatment with p value less than 0.05. There was a mean reduction of 3.08 and 1.71 on VAS across the core stabilization group and routine physical therapy exercise group respectively. Core stabilization exercise is more effective than routine physical therapy exercise in terms of greater reduction in pain in patients with

  17. Routine Urine Culture at the Time of Percutaneous Urinary Drainage: Does Every Patient Need One?

    International Nuclear Information System (INIS)

    Brody, L.A.; Brown, K.T.; Covey, A.M.; Brown, A.E.; Getrajdman, G.I.

    2006-01-01

    Purpose. To determine the clinical variables associated with bacteriuria in patients undergoing primary percutaneous antegrade urinary drainage procedures in order to predict the utility of routinely obtaining urine cultures at the time of the procedure. Methods. Between October 1995 and March 1998 urine cultures were prospectively obtained in all patients undergoing a primary percutaneous antegrade urinary drainage procedure. One hundred and eighty-seven patients underwent 264 procedures. Results were available in 252 cases. Culture results were correlated with clinical, laboratory, and demographic variables. Anaerobic cultures were not uniformly performed. Results. Urine cultures were positive in 24 of 252 (9.5%) cases. An indwelling or recently removed ipsilateral device (catheter or stent) and a history of previous cystectomy with urinary diversion were significant predictors of a positive culture. Patients without either of these predictors, and without clinical or laboratory evidence of infection, were rarely found to have positive cultures. Conclusion. The likelihood of a positive urine culture can be predicted on the basis of the aforementioned clinical variables. In the absence of these clinical indicators routine urine cultures are neither useful nor cost-effective

  18. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    Science.gov (United States)

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Comparison of tetrazolium colorimetric and [3H]-uridine assays for in vitro chemosensitivity testing.

    Science.gov (United States)

    Ford, C H; Richardson, V J; Tsaltas, G

    1989-01-01

    We have routinely used a [3H]-uridine microplate assay for assessing chemosensitivity. A colorimetric assay with the advantages of safety, cost and simplicity has previously been described and relies on the ability of living cells to reduce a soluble tetrazolium salt, 3-4,5-dimethylthiazol-2,5-diphenyl-tetrazolium bromide (MMT), into an insoluble formazan precipitate. We compared the chemosensitivity of 14 human tumour cell lines of colonic, lung and cervical carcinoma origin to doxorubicin, vindesine or vindesine immunoconjugates in both the [3H]-uridine assay and a modified MTT assay to evaluate whether we could change to the non-radiolabelled method. Correlation between the concentration of drug causing 50% inhibition of cell growth (IC50) for these agents between the two assays was very poor. However, taking account of recent reports in the literature, we modified the MTT assay by removing serum-containing medium and using dimethyl sulphoxide to solubilise the formazan precipitate. This considerably improved the correlation between the assays for doxorubicin (r = 0.871; P = 0.001) and vindesine (r = 0.981; P less than 0.001). Our data indicates that the MTT assay can be used to replace the [3H]-uridine assay for chemosensitivity screening, but further modifications are necessary to improve the sensitivity and decrease the problem of cell loss after washing, which was noted with some adherent cell lines.

  20. Routine general practice care for panic disorder within the lifestyle approach to managing panic study

    Directory of Open Access Journals (Sweden)

    Rodney A. Lambert

    2012-07-01

    Full Text Available Routine general practice (GP care is rarely comprehensively described in clinical trials. This paper examines routine GP care within the lifestyle approach to managing panic (LAMP study. The aim of this paper is to describe/discuss routine GP care for panic disorder (PD patients within both study arms in the LAMP study. An unblinded pragmatic randomised controlled trial in 15 East of England GP practices (2 primary care trusts. Participants met Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria for PD with/without agoraphobia. Follow-up measures recorded at 20 weeks/10 months following randomisation. Control arm, unrestricted routine GP care (practice appointments, referrals and prescriptions. Trial arm, occupational therapyled lifestyle treatment comprising lifestyle review of fluid intake, diet pattern, exercise, caffeine, alcohol and nicotine. Primary outcome measure: beck anxiety inventory. At baseline, participants attended 2-3 times more GP appointments than population average, reducing at 10 months to 1.6 times population average for routine GP care and 0.97 population average for lifestyle arm. At 10 months, 33% fewer referrals (6 referrals; 0 mental health than at baseline (9 referrals; 2 mental health were made for lifestyle arm patients compared with 42% increase (from 12 referrals; 8 mental health at baseline to 17 referrals; 7 mental health in GP care arm. Selective serotonin reuptake inhibitors were prescribed most often. Benzodiazepines and beta-blockers were prescribed more often than tricyclic against current clinical guidelines. In conclusion, we found that PD patients at baseline were high healthcare resource users. Treatment in both study arms reduced resource use. Routine GP care requires further review for this patient group.