WorldWideScience

Sample records for rotationally accelerating coils

  1. In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.

    Science.gov (United States)

    Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart

    2015-03-01

    Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1(-)) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. A procedure for combining rotating-coil measurements of large-aperture accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Köster, Oliver, E-mail: oliver.koester@cern.ch; Fiscarelli, Lucio, E-mail: lucio.fiscarelli@cern.ch; Russenschuck, Stephan, E-mail: stephan.russenschuck@cern.ch

    2016-05-11

    The rotating search coil is a precise and widely used tool for measuring the magnetic field harmonics of accelerator magnets. This paper deals with combining several such multipole measurements, in order to cover magnet apertures largely exceeding the diameter of the available search coil. The method relies on the scaling laws for multipole coefficients and on the method of analytic continuation along zero-homotopic paths. By acquiring several measurements of the integrated magnetic flux density at different transverse positions within the bore of the accelerator magnet, the uncertainty on the field harmonics can be reduced at the expense of tight tolerances on the positioning. These positioning tolerances can be kept under control by mounting the rotating coil and its motor-drive unit on precision alignment stages. Therefore, the proposed technique is able to yield even more precise results for the higher-order field components than a dedicated rotating search coil of larger diameter. Moreover, the versatility of the measurement bench is enhanced by avoiding the construction of rotating search coils of different measurement radii.

  3. Combining rotating-coil measurements of large-aperture accelerator magnets

    CERN Document Server

    AUTHOR|(CDS)2089510

    2016-10-05

    The rotating coil is a widely used tool to measure the magnetic field and the field errors in accelerator magnets. The coil has a length that exceeds the entire magnetic field along the longitudinal dimension of the magnet and gives therefore a two-dimensional representation of the integrated field. Having a very good precision, the rotating coil lacks in versatility. The fixed dimensions make it impractical and inapplicable in situations, when the radial coil dimension is much smaller than the aperture or when the aperture is only little covered by the coil. That being the case for rectangular apertures with large aspect ratio, where a basic measurement by the rotating coil describes the field only in a small area of the magnet. A combination of several measurements at different positions is the topic of this work. Very important for a combination is the error distribution on the measured field harmonics. To preserve the good precision of the higher-order harmonics, the combination must not rely on the main ...

  4. Magnetic field mapper based on rotating coils

    CERN Document Server

    AUTHOR|(CDS)2087244; Arpaia, Pasquale

    This thesis presents a magnetic field mapper based on rotating coils. The requirements, the architecture, the conceptual design, and the prototype for straight magnets were shown. The proposed system is made up of a rotating coil transducer and a train-like system for longitudinal motion and positioning inside magnet bore. The mapper allows a localized measurement of magnetic fields and the variation of the harmonic multipole content in the magnet ends. The proof-of-principle demonstration and the experimental characterization of the rotating-coil transducer specifically conceived for mapping validated the main objective of satisfying the magnetic measurement needs of the next generation of compact accelerators.

  5. Accelerated tests of coil coatings

    Directory of Open Access Journals (Sweden)

    Rosales, B. M.

    2003-12-01

    Full Text Available Accelerated laboratory tests on 12 materials in study in the Subgroup 6 of the PATINA Network (CYTED, are discussed for different exposition periods in salt spray, SO2 and Prohesion chambers. International standards used to evaluate failures caused by the different aggressive agents of these laboratory tests are the same as those applied for outdoor expositions. The results exposed contribute to a better understanding of the mechanisms occurred in the diverse natural environments, being mentioned the main analogies and differences respect to factors affecting natural tests. They also allowed to evidence the advantages and limitations in the application of these tests during several days, as compared to the years required to attain similar failure magnitudes through outdoor tests.

    En este trabajo se discuten los ensayos de laboratorio acelerados, realizados sobre 12 materiales de estudio en el Subgrupo 6 de la Red PATINA (CYTED, a diferentes periodos de exposición en cámaras de niebla salina, SO2 y Prohesion. Se utilizaron las normas internacionales para evaluar los fallos causados por los diferentes agentes agresivos de estos ensayos de laboratorio, las cuales se aplican también para los ensayos de exposición a la intemperie. Los resultados expuestos contribuyen a una mejor comprensión de los mecanismos ocurridos en los diversos ambientes naturales, mencionándose las principales analogías y diferencias respecto de los factores que afectan los ensayos naturales. También permitieron evidenciar las ventajas y limitaciones en la aplicación de estos ensayos durante varios días, en comparación con los años requeridos para alcanzar magnitudes de fallos similares por medio de ensayos a intemperie.

  6. An Air Bearing Rotating Coil Magnetic Measurement System

    CERN Document Server

    Gottschalk, Stephen C; Taylor, David J; Thayer, William

    2005-01-01

    This paper describes a rotating coil magnetic measurement system supported on air bearings. The design is optimized for measurements of 0.1micron magnetic centerline changes on long, small aperture quadrupoles. Graphite impregnated epoxy resin is used for the coil holder and coil winding forms. Coil holder diameter is 11 mm with a length between supports of 750mm. A pair of coils is used to permit quadrupole bucking during centerline measurements. Coil length is 616mm, inner radius 1.82mm, outer radius 4.74mm. The key features of the mechanical system are simplicity; air bearings for accurate, repeatable measurements without needing warm up time and a vibration isolated stand that uses a steel-topped Newport optical table with air suspension. Coil rotation is achieved by a low noise servo motor controlled by a standalone Ethernet servo board running custom servo software. Coil calibration procedures that correct wire placement errors, tests for mechanical resonances, and other system checks will also be discu...

  7. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    Energy Technology Data Exchange (ETDEWEB)

    Oomen, Marijn, E-mail: marijn.oomen@siemens.com [Siemens AG, Corporate Technology, CT T DE HW4, PO Box 3220, 91050 Erlangen (Germany); Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea [Siemens AG, Corporate Technology, CT T DE HW4, PO Box 3220, 91050 Erlangen (Germany)

    2012-11-20

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  8. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    Science.gov (United States)

    Oomen, Marijn; Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea

    2012-11-01

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  9. Digital Integrator for Fast Accurate Measurement of Magnetic Flux by Rotating Coils

    CERN Document Server

    Arpaia, P; Spiezia, G

    2007-01-01

    A fast digital integrator (FDI) with dynamic accuracy and a trigger frequency higher than those of a portable digital integrator (PDI), which is a state-of-the-art instrument for magnetic measurements based on rotating coils, was developed for analyzing superconducting magnets in particle accelerators. Results of static and dynamic metrological characterization show how the FDI prototype is already capable of overcoming the dynamic performance of PDI as well as covering operating regions that used to be inaccessible

  10. Electrical engineering. Coiling of rotating machines; Genie electrique. Bobinage des machines tournantes a courant alternatif

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Michel, J. [Moteurs Leroy Somer, 16 - Angouleme (France)

    2001-02-01

    This article treats of the poly-phase coiling of AC rotating machines. For simplification reasons, the study has been limited to tri-phase coils, but the theoretical calculations can be extended to any other number of phases. The coils described are those encountered in the stators of synchronous and asynchronous machines and in the rotors of asynchronous machines with rings. The qualitative, quantitative and practical aspects are presented successively: 1 - magnetic field produced by a coil (single turn, distributed coil, coil schemes, multi-polarity coils); 2 - field generated by a tri-phase coil (rotating field theorem, qualitative influence of space harmonics); 3 - quantitative analysis of coil properties (magneto-motive force generated by coils, harmonic decomposition of the magneto-motive force wave, global coiling coefficients); 4 - comparative study of different regular coils (diametrical step, shortened step, distributed); 5 - irregular coils; 6 - other double polarity coils (Dahlander coupling, other multiple polarity possibilities); 7 - reduction of teething harmonics (determination of optimal twisting, influence of inclination on the dimensioning of machines); 8 - practical realization of coils (insulation, insertion inside the machine). (J.S.)

  11. Radial Acceleration Relation in Rotationally Supported Galaxies

    Science.gov (United States)

    McGaugh, Stacy S.; Lelli, Federico; Schombert, James M.

    2016-11-01

    We report a correlation between the radial acceleration traced by rotation curves and that predicted by the observed distribution of baryons. The same relation is followed by 2693 points in 153 galaxies with very different morphologies, masses, sizes, and gas fractions. The correlation persists even when dark matter dominates. Consequently, the dark matter contribution is fully specified by that of the baryons. The observed scatter is small and largely dominated by observational uncertainties. This radial acceleration relation is tantamount to a natural law for rotating galaxies.

  12. Accelerated rotation with orbital angular momentum modes

    CSIR Research Space (South Africa)

    Schulze, C

    2015-04-01

    Full Text Available A 91, 043821 (2015) Accelerated rotation with orbital angular momentum modes Christian Schulze, Filippus S. Roux, Angela Dudley, Ronald Rop, Michael Duparr´e, and Andrew Forbes Abstract: We introduce a class of light field that angularly...

  13. Nested Helmholtz coil design for producing homogeneous transient rotating magnetic fields.

    Science.gov (United States)

    Podaru, George; Moore, John; Dani, Raj Kumar; Prakash, Punit; Chikan, Viktor

    2015-03-01

    Electromagnets that can produce strong rotating magnetic fields at kHz frequencies are potentially very useful to exert rotating force on magnetic nanoparticles as small as few nanometers in size. In this article, the construction of a pulsed high-voltage rotating electromagnet is demonstrated based on a nested Helmholtz coil design. The energy for the coils is provided by two high-voltage discharge capacitors. The triggered spark gaps used in the experiments show sufficient accuracy to achieve the high frequency rotating magnetic field. The measured strength of the rotating magnetic field is 200 mT. This magnetic field is scalable by increasing the number of turns on the coils, by reducing the dimensions of the coils and by increasing the discharge current/voltage of the capacitors.

  14. Accelerated rotation with orbital angular momentum modes

    CSIR Research Space (South Africa)

    Schulze, C

    2015-01-01

    Full Text Available during propagation for selected values of the morphology parameter θ are shown 043821-3 CHRISTIAN SCHULZE et al. PHYSICAL REVIEW A 91, 043821 (2015) FIG. 3. (Color online) The intensity images in the top rows of (a) and (b) show the petal rotation at a... a z-dependent orientation, given by Eqs. (17) and (18) for the sum and difference terms, 043821-4 ACCELERATED ROTATION WITH ORBITAL ANGULAR . . . PHYSICAL REVIEW A 91, 043821 (2015) (a) (b) θ θ π θ π θ π θ θ π θ π θ π FIG. 4. (Color online...

  15. A Novel Tetrahedral Mesh Generation Method for Rotating Machines Including End-Coil Region

    OpenAIRE

    Yamashita, Hideo; Yamaji, Akihisa; Cingoski, Vlatko; Kaneda, Kazufumi

    1996-01-01

    In this paper, a novel method for generating tetrahedral finite-element meshes suitable for 3-D finite element analysis of rotating machines is presented. The proposed method enables the easy development of 3-D meshes for various rotating machines, especially in the end-coil region and the surrounding air region. Tessellation of the 3-D region is made possible by simple extension of a previously generated 2-D triangular mesh, used as a model mesh, into the third dimension.

  16. Twin Rotating Coils for Cold Magnetic Measurements of 15 m Long LHC Dipoles

    CERN Document Server

    Billan, J; Buzio, M; D'Angelo, G; Deferne, G; Dunkel, O; Legrand, P; Rijllart, A; Siemko, A; Sievers, P; Schloss, S; Walckiers, L

    2000-01-01

    We describe here a new harmonic coil system for the field measurement of the superconducting, twin aperture LHC dipoles and the associated corrector magnets. Besides field measurements the system can be used as an antenna to localize the quench origin. The main component is a 16 m long rotating shaft, made up of 13 ceramic segments, each carrying two tangential coils plus a central radial coil, all working in parallel. The segments are connected with flexible Ti-alloy bellows, allowing the piecewise straight shaft to follow the curvature of the dipole while maintaining high torsional rigidity. At each interconnection the structure is supported by rollers and ball bearings, necessary for the axial movement for installation and for the rotation of the coil during measurement. Two such shafts are simultaneously driven by a twin-rotating unit, thus measuring both apertures of a dipole at the same time. This arrangement allows very short measurement times (typically 10 s) and is essential to perform cold magnetic ...

  17. Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonance.

    Science.gov (United States)

    Trakic, Adnan; Weber, Ewald; Li, Bing Keong; Wang, Hua; Liu, Feng; Engstrom, Craig; Crozier, Stuart

    2012-04-01

    While recent studies have shown that rotating a single radio-frequency (RF) coil during the acquisition of magnetic resonance (MR) images provides a number of hardware advantages (i.e., requires only one RF channel, avoids coil-coil coupling and facilitates large-scale multinuclear imaging), they did not describe in detail how to build a rotating RF coil system. This paper presents detailed engineering information on the electromechanical design and construction of a MR-compatible RRFC system for human head imaging at 2 T. A custom-made (bladeless) pneumatic Tesla turbine was used to rotate the RF coil at a constant velocity, while an infrared optical encoder measured the selected frequency of rotation. Once the rotating structure was mechanically balanced and the compressed air supply suitably regulated, the maximum frequency of rotation measured ~14.5 Hz with a 2.4% frequency variation over time. MR images of a water phantom and human head were obtained using the rotating RF head coil system.

  18. Effect of Inductive Coil Geometry and Current Sheet Trajectory of a Conical Theta Pinch Pulsed Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Bonds, Kevin W.; Emsellem, Gregory D.

    2011-01-01

    Results are presented demonstrating the e ect of inductive coil geometry and current sheet trajectory on the exhaust velocity of propellant in conical theta pinch pulsed induc- tive plasma accelerators. The electromagnetic coupling between the inductive coil of the accelerator and a plasma current sheet is simulated, substituting a conical copper frustum for the plasma. The variation of system inductance as a function of plasma position is obtained by displacing the simulated current sheet from the coil while measuring the total inductance of the coil. Four coils of differing geometries were employed, and the total inductance of each coil was measured as a function of the axial displacement of two sep- arate copper frusta both having the same cone angle and length as the coil but with one compressed to a smaller size relative to the coil. The measured relationship between total coil inductance and current sheet position closes a dynamical circuit model that is used to calculate the resulting current sheet velocity for various coil and current sheet con gura- tions. The results of this model, which neglects the pinching contribution to thrust, radial propellant con nement, and plume divergence, indicate that in a conical theta pinch ge- ometry current sheet pinching is detrimental to thruster performance, reducing the kinetic energy of the exhausting propellant by up to 50% (at the upper bound for the parameter range of the study). The decrease in exhaust velocity was larger for coils and simulated current sheets of smaller half cone angles. An upper bound for the pinching contribution to thrust is estimated for typical operating parameters. Measurements of coil inductance for three di erent current sheet pinching conditions are used to estimate the magnetic pressure as a function of current sheet radial compression. The gas-dynamic contribution to axial acceleration is also estimated and shown to not compensate for the decrease in axial electromagnetic acceleration

  19. Liquid nitrogen tests of a Torus coil for the Jefferson Lab 12GeV accelerator upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Fair, Ruben J. [JLAB; Ghoshal, Probir K. [JLAB; Bruhwel, Krister B. [JLAB; Kashy, David H. [JLAB; Machie, Danny [JLAB; Bachimanchi, Ramakrishna [JLAB; Taylor, William; Fischer, John W. [JLAB; Legg, Robert A. [JLAB; Powers, Jacob R. [JLAB

    2015-06-01

    A magnet system consisting of six superconducting trapezoidal racetrack-type coils is being built for the Jefferson Lab 12-GeV accelerator upgrade project. The magnet coils are wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. Each superconducting toroidal coil is force cooled by liquid helium, which circulates in a tube that is in good thermal contact with the inside of the coil. Thin copper sheets are soldered to the helium cooling tube and enclose the superconducting coil, providing cooling to the rest of the coil pack. As part of a rigorous risk mitigation exercise, each of the six coils is cooled with liquid nitrogen (LN2) to 80 K to validate predicted thermal stresses, verify the robustness and integrity of electrical insulation, and evaluate the efficacy of the employed conduction cooling method. This paper describes the test setup, the tests performed, and the findings.

  20. The Radial Acceleration Relation in Rotationally Supported Galaxies

    CERN Document Server

    McGaugh, Stacy; Schombert, Jim

    2016-01-01

    We report a correlation between the radial acceleration traced by rotation curves and that predicted by the observed distribution of baryons. The same relation is followed by 2693 points in 153 galaxies with very different morphologies, masses, sizes, and gas fractions. The correlation persists even when dark matter dominates. Consequently, the dark matter contribution is fully specified by that of the baryons. The observed scatter is small and largely dominated by observational uncertainties. This radial acceleration relation is tantamount to a natural law for rotating galaxies.

  1. Exploration of highly accelerated magnetic resonance elastography using high-density array coils

    Science.gov (United States)

    Bosshard, John C.; Yallapragada, Naresh; McDougall, Mary P.

    2017-01-01

    Background Magnetic resonance elastography (MRE) measures tissue mechanical properties by applying a shear wave and capturing its propagation using magnetic resonance imaging (MRI). By using high density array coils, MRE images are acquired using single echo acquisition (SEA) and at high resolutions with significantly reduced scan times. Methods Sixty-four channel uniplanar and 32×32 channel biplanar receive arrays are used to acquire MRE wave image sets from agar samples containing regions of varying stiffness. A mechanical actuator triggered by a stepped delay time introduces vibrations into the sample while a motion sensitizing gradient encodes micrometer displacements into the phase. SEA imaging is used to acquire each temporal offset in a single echo, while multiple echoes from the same array are employed for highly accelerated imaging at high resolutions. Additionally, stiffness variations as a function of temperature are studied by using a localized heat source above the sample. A custom insertable gradient coil is employed for phase compensation of SEA imaging with the biplanar array to allow imaging of multiple slices. Results SEA MRE images show a mechanical shear wave propagating into and across agar samples. A set of 720 images was obtained in 720 echoes, plus a single reference scan for both harmonic and transient MRE. A set of 2,950 wave image frames was acquired from pairs of SEA images captured during heating, showing the change in mechanical wavelength with the change in agar properties. A set of 240 frames was acquired from two slices simultaneously using the biplanar array, with phase images processed into displacement maps. Combining the narrow sensitivity patterns and SNR advantage of the SEA array coil geometry allowed acquisition of a data set with a resolution of 156 µm × 125 µm × 1,000 µm in only 64 echoes, demonstrating high resolution and high acceleration factors. Conclusions MRE using high-density arrays offers the unique ability

  2. Charged fermions tunneling from accelerating and rotating black holes

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Mudassar; Saifullah, K., E-mail: mudassir051@yahoo.com, E-mail: saifullah@qau.edu.pk [Department of Mathematics, Quaid-i-Azam University, Islamabad (Pakistan)

    2011-03-01

    We study Hawking radiation of charged fermions from accelerating and rotating black holes with electric and magnetic charges. We calculate the tunneling probabilities of incoming and outgoing fermionic particles and find the Hawking temperature of these black holes. We also provide an explicit expression of the classical action for the massive and massless particles in the background of these black holes.

  3. Periodic Relativity: Deflection of Light, Acceleration, Rotation Curves

    Directory of Open Access Journals (Sweden)

    Zaveri V. H.

    2015-01-01

    Full Text Available Vectorial analysis relating to derivation of deflection of light is presented. Curvilinear acceleration is distinguished from the Newtonian polar conic acceleration. The dif- ference between the two is due to the curvature term. Lorentz invariant expression for acceleration is derived. A physical theory of rotation curves of galaxies based on second solution to Einstein’s field equation is presented. Theory is applied to Milky Way, M31, NGC3198 and Solar system. Modified Kepler’s third law yields correct orbital periods of stars in a galaxy. Deviation factor in the line element of t he theory happens to be the ratio of the Newtonian gravitational acceleration to th e measured acceleration of the star in the galaxy. Therefore this deviation factor can replace the MOND function.

  4. Effect of Inductive Coil Geometry on the Operating Characteristics of a Pulsed Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Kimberlin, Adam C.

    2012-01-01

    Operational characteristics of two separate inductive thrusters with coils of different cone angles are explored through thrust stand measurements and time-integrated, un- filtered photography. Trends in impulse bit measurements indicate that, in the present experimental configuration, the thruster with the inductive coil possessing a smaller cone angle produced larger values of thrust, in apparent contradiction to results of a previous thruster acceleration model. Areas of greater light intensity in photographs of thruster operation are assumed to qualitatively represent locations of increased current density. Light intensity is generally greater in images of the thruster with the smaller cone angle when compared to those of the thruster with the larger half cone angle for the same operating conditions. The intensity generally decreases in both thrusters for decreasing mass ow rate and capacitor voltage. The location of brightest light intensity shifts upstream for decreasing mass ow rate of propellant and downstream for decreasing applied voltage. Recognizing that there typically exists an optimum ratio of applied electric field to gas pressure with respect to breakdown efficiency, this result may indicate that the optimum ratio was not achieved uniformly over the coil face, leading to non-uniform and incomplete current sheet formation in violation of the model assumption of immediate formation where all the injected propellant is contained in a magnetically-impermeable current sheet.

  5. Radiation from an accelerating neutral body: The case of rotation

    Science.gov (United States)

    Yarman, Tolga; Arik, Metin; Kholmetskii, Alexander L.

    2013-11-01

    When an object is bound at rest to an attractional field, its rest mass (owing to the law of energy conservation, including the mass and energy equivalence of the Special Theory of Relativity) must decrease. The mass deficiency coming into play indicates a corresponding rest energy discharge. Thus, bringing an object to a rotational motion means that the energy transferred for this purpose serves to extract just as much rest mass (or similarly "rest energy", were the speed of light in empty space taken to be unity) out of it. Here, it is shown that during angular acceleration, photons of fundamental energy are emitted, while the object is kept on being delivered to a more and more intense rotational accelerational field, being the instantaneous angular velocity of the rotating object. This fundamental energy, as seen, does not depend on anything else (such as the mass or charge of the object), and it is in harmony with Bohr's Principle of Correspondence. This means at the same time, that emission will be achieved, as long as the angular velocity keeps on increasing, and will cease right after the object reaches a stationary rotational motion (a constant centrifugal acceleration), but if the object were brought to rotation in vacuum with no friction. By the same token, one can affirm that even the rotation at a macroscopic level is quantized, and can only take on "given angular velocities" (which can only be increased, bit by bit). The rate of emission of photons of concern is, on the other hand, proportional to the angular acceleration of the object, similarly to the derivative of the tangential acceleration with respect to time. It is thus constant for a "constant angular acceleration", although the energy of the emitted photons will increase with increasing , until the rotation reaches a stationary level, after which we expect no emission --let us stress-- if the object is in rotation in vacuum, along with no whatsoever friction (such as the case of a rotating

  6. Rotational total skin electron irradiation with a linear accelerator.

    Science.gov (United States)

    Reynard, Eric P; Evans, Michael D C; Devic, Slobodan; Parker, William; Freeman, Carolyn R; Roberge, David; Podgorsak, Ervin B

    2008-11-03

    The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source-to-surface distance of 380 cm. The electron field is produced by a Varian 21EX linear accelerator using the commercially available 6 MeV high dose rate total skin electron mode, along with a custom-built flattening filter. Ionization chambers, radiochromic film, and MOSFET (metal oxide semiconductor field effect transistor) detectors have been used to determine the dosimetric properties of this technique. Measurements investigating the stationary beam properties, the effects of full rotation, and the dose distributions to a humanoid phantom are reported. The current treatment technique and dose regimen are also described.

  7. Unscented transform-based uncertainty analysis of rotating coil transducers for field mapping

    Science.gov (United States)

    Arpaia, P.; De Matteis, E.; Schiano Lo Moriello, R.

    2016-03-01

    The uncertainty of a rotating coil transducer for magnetic field mapping is analyzed. Unscented transform and statistical design of experiments are combined to determine magnetic field expectation, standard uncertainty, and separate contributions of the uncertainty sources. For nonlinear measurement models, the unscented transform-based approach is more error-proof than the linearization underlying the "Guide to the expression of Uncertainty in Measurements" (GUMs), owing to the absence of model approximations and derivatives computation. When GUM assumptions are not met, the deterministic sampling strategy strongly reduces computational burden with respect to Monte Carlo-based methods proposed by the Supplement 1 of the GUM. Furthermore, the design of experiments and the associated statistical analysis allow the uncertainty sources domain to be explored efficiently, as well as their significance and single contributions to be assessed for an effective setup configuration. A straightforward experimental case study highlights that a one-order-of-magnitude reduction in the relative uncertainty of the coil area produces a decrease in uncertainty of the field mapping transducer by a factor of 25 with respect to the worst condition. Moreover, about 700 trials and the related processing achieve results corresponding to 5 × 106 brute-force Monte Carlo simulations.

  8. Effect of Inductive Coil Geometry on the Thrust Efficiency of a Microwave Assisted Discharge Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley; Polzin, Kurt; Emsellem, Gregory

    2012-01-01

    Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) [4, 5] is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and permanent magnets that are arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the inductive coil is high. The use of a conical theta-pinch coil is under investigation. The conical geometry serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [2, 3], however a conical coil imparts a direct radial acceleration of the current sheet that serves to rapidly decouple the propellant from the coil, limiting the direct axial electromagnetic acceleration in favor of an indirect acceleration mechanism that requires significant heating of the propellant within the volume bounded by the current sheet. In this paper, we describe thrust stand measurements performed to characterize the performance

  9. Rotating and accelerating black holes with cosmological constant

    CERN Document Server

    Chen, Yu; Teo, Edward

    2016-01-01

    We propose a new form of the rotating C-metric with cosmological constant, which generalises the form found by Hong and Teo for the Ricci-flat case. This solution describes the entire class of spherical black holes undergoing rotation and acceleration in dS or AdS space-time. The new form allows us to identify the complete ranges of coordinates and parameters of this solution. We perform a systematic study of its geometrical and physical properties, and of the various limiting cases that arise from it.

  10. Exploring phase space using smartphone acceleration and rotation sensors simultaneously

    Science.gov (United States)

    Monteiro, Martín; Cabeza, Cecilia; Martí, Arturo C.

    2014-07-01

    A paradigmatic physical system as the physical pendulum is experimentally studied using the acceleration and rotation (gyroscope) sensors available on smartphones and other devices such as iPads and tablets. A smartphone is fixed to the outside of a bicycle wheel whose axis is kept horizontal and fixed. The compound system, wheel plus smartphone, defines a physical pendulum which can rotate, giving full turns in one direction, or oscillate about the equilibrium position (performing either small or large oscillations). Measurements of the radial and tangential acceleration and the angular velocity obtained with smartphone sensors allow a deep insight into the dynamics of the system to be gained. In addition, thanks to the simultaneous use of the acceleration and rotation sensors, trajectories in the phase space are directly obtained. The coherence of the measures obtained with the different sensors and by traditional methods is remarkable. Indeed, due to their low cost and increasing availability, smartphone sensors are valuable tools that can be used in most undergraduate laboratories.

  11. Vestibulo-ocular reflex of the squirrel monkey during eccentric rotation with centripetal acceleration along the naso-occipital axis

    Science.gov (United States)

    Merfeld, D. M.; Paloski, W. H. (Principal Investigator)

    1996-01-01

    The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in four male squirrel monkeys. Monkeys were rotated in the dark at 200 degrees/s, centrally or 79 cm off-axis, with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's position relative to the centripetal acceleration (facing center or back to center) had a dramatic influence on the VOR. These studies show that a torsional response was always elicited that acted to shift the axis of eye rotation toward alignment with gravito-inertial force. On the other hand, a slow phase downward vertical response usually existed, which shifted the axis of eye rotation away from the gravito-inertial force. These findings were consistent across all monkeys. In another set of tests, the same monkeys were rapidly tilted about their interaural (pitch) axis. Tilt orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the rotation, no consistent eye velocity response was ever observed during or following the tilt. The absence of any response following tilt proves that the observed torsional and vertical responses were not a positional nystagmus. Model simulations qualitatively predict all components of these eccentric rotation and tilt responses. These simulations support the conclusion that the VOR during eccentric rotation may consist of two components: a linear VOR and a rotational VOR. The model predicts a slow phase downward, vertical, linear VOR during eccentric rotation even though there was never a change in the force aligned with monkey's spinal (Z) axis. The model also predicts the torsional components of the response that shift the rotation axis of the angular VOR toward alignment with gravito-inertial force.

  12. Protective link for superconducting coil

    Science.gov (United States)

    Umans, Stephen D.

    2009-12-08

    A superconducting coil system includes a superconducting coil and a protective link of superconducting material coupled to the superconducting coil. A rotating machine includes first and second coils and a protective link of superconducting material. The second coil is operable to rotate with respect to the first coil. One of the first and second coils is a superconducting coil. The protective link is coupled to the superconducting coil.

  13. METRIC OF ACCELERATING AND ROTATING REFERENCE SYSTEMS IN GENERAL RELATIVITY

    Directory of Open Access Journals (Sweden)

    Trunev A. P.

    2015-03-01

    Full Text Available Metric describing the accelerated and rotating reference system in general relativity in the case of an arbitrary dependence of acceleration and angular velocity on time has been proposed. It is established that the curvature tensor in such metrics is zero, which corresponds to movement in the flat spaces. It is shown that the motion of test bodies in the metric accelerated and rotating reference system in general relativity is similarly to the classical motion in non-inertial reference frame. Consequently, there exist a metric in general relativity, in which the Coriolis theorem and classic velocity-addition formula are true. This means that classical mechanics is accurate rather than approximate model in general relativity. A theory of potential in non-inertial reference systems in general relativity is considered. The numerical model of wave propagation in non-inertial reference frames in the case when potential depending of one, two and three spatial dimensions has been developed. It is shown in numerical experiment that the acceleration of the reference system leads to retardation effects, as well as to a violation of the symmetry of the wave front, indicating that there is local change of wave speed

  14. Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics

    CERN Document Server

    Arpaia, Pasquale; Köster, Oliver; Russenschuck, Stephan; Severino, Giordana; 10.1016/j.measurement.2016.02.061

    2016-01-01

    A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit is analyzed. Then, the error arising from higher-order harmonic field imperfections in the reference quadrupole is assessed. The method is validated by numerical field computation for both the higher-order harmonic errors and the roll-angle misalignment. Finally, an experimental proof-of-principle demonstration is car-ried out in a calibration magnet with sextupole harmonic.

  15. Prediction of secular acceleration of axial rotation of Mars

    Science.gov (United States)

    Barkin, Yu. V.

    2009-04-01

    Secular motion of the Earth pole and non-tidal acceleration of its diurnal rotation have obtained rather precise explanation with the help of simple one-point model of the directed transport of fluid masses from a southern hemisphere in northern hemisphere with the general direction, given by geocentric axis OP directed to pole P with coordinates 700N, 10403 E[1]. The another generalized model represents a system of two material points with masses m2 and m1, located on surface of the Earth at poles of geocentric axis OP. Masses are linearly changed in the time with velocities [2]: ṁ2 = 0.179 × 1015kg/yrand ṁ1 = 0.043 × 1015kg/yr. A reduction of fluid masses of the appropriate thin spherical layer of the Earth correspond to secular increasing of masses of model points. The specified model has allowed to explain values of fundamental geodynamic parameters observably and determined during decades: a direction and velocity of drift of a pole of the Earth; value of non-tidal acceleration of axial rotation; to explain a secular variations of coefficients of the second, third, fourth, sixth and eighth zonal harmonics of a geopotential; coefficients of secular changes of a surface of ocean for the last approximately 150 years; a direction of secular drift of a geocenter and other planetary phenomena [3]. The role of the angular momentum of redistributed masses of the Earth in rotation of the Earth appeared not essential at the given stage of researches. On the essence the offered model has semi-empirical character as it bases on values of velocities of change of masses of points and the given position of axis OP. For their determination and estimations the part of the observant data was used, and other parameters were designed under analytical formulas. The obtained results have precisely confirmed competency and affectivity of geodynamic model [4] about existence of secular drift of a liquid core along radial direction OP with velocity about 2.6 cm/yr in the

  16. Quench absorption coils: a quench protection concept for high-field superconducting accelerator magnets

    Science.gov (United States)

    Mentink, M.; Salmi, T.

    2017-06-01

    A quench protection concept based on coupled secondary coils is studied for inductively transferring energy out of a quenching superconducting dipole and thus limiting the peak hotspot temperature. So-called ‘quench absorption coils’ are placed in close proximity to the superconducting coils and are connected in series with a diode for the purpose of preventing current transformation during regular operation. During a quench, current is then transformed into the quench absorption coils so that a significant fraction of the stored magnetic energy is dissipated in the these coils. Numerical calculations are performed to determine the impact of such a concept and to evaluate the dimensions of the quench absorption coils needed to obtain significant benefits. A previously constructed 15 T Nb3Sn block coil is taken as a reference layout. Finite-element calculations are used to determine the combined inductive and thermal response of this system and these calculations are validated with a numerical model using an adiabatic approximation. The calculation results indicate that during a quench the presence of the quench absorption coils reduces the energy dissipated in the superconducting coils by 45% and reduces the hotspot temperature by over 100 K. In addition, the peak resistive voltage over the superconducting coils is significantly reduced. This suggests that this concept may prove useful for magnet designs in which the hotspot temperature is a design driver.

  17. Mesenchymal stem cells and endothelial progenitor cells accelerate intra-aneurysmal tissue organization after treatment with SDF-1α-coated coils.

    Science.gov (United States)

    Gao, Yuyuan; Lu, Ziming; Chen, Chengwei; Cui, Xubo; Liu, Yaqi; Zheng, Tao; Jiang, Xiaodan; Zeng, Chi; Quan, Daping; Wang, Qiujing

    2016-04-01

    Recurrences of aneurysms remain the major drawback of detachable coils for the endovascular treatment of intracranial aneurysms. The aim of the present study is to develop new modified coils, coating the surface of platinum coils with silk fibroin (SF) consisting of stromal cell-derived factor-1α (SDF-1α), and evaluate its acceleration of organization of cavities and reduction of lumen size in a rat aneurysm model. The morphological characteristics of SDF-1α-coated coils were examined using scanning electron microscopy (SEM). Fifty experimental aneurysms were created and randomly divided into five groups: three groups were embolized with SDF-1α-coated coils (8 mm) and two of these groups need transplantation of mesenchymal stem cells (MSCs) or endothelial progenitor cells (EPCs); one group was embolized with bare coils (8 mm) and another group severed as control. After coil implantation for 14 or 28 days, the coils were harvested and histological analysis was performed. SEM photographs showed that SF/SDF-1α-coated coils have uniform size and a thin film compared with bare coils. In the group treated with SDF-1α-coated coils, tissue organization was accelerated and the proliferation of α-smooth muscle actin positive cells was promoted in the aneurysmal sac. Compared with unmodified coils, on day 28, tissue organization was significantly greater in the group treated with SDF-1α-coated coils and MSC or EPC transplantation. These results suggest that SDF-1α-coated coils with MSC or EPC transplantation may be beneficial in the aneurysm healing and endothelialization at the orifice of embolized aneurysm.

  18. Accelerated proton echo planar spectroscopic imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil.

    Science.gov (United States)

    Tsai, Shang-Yueh; Otazo, Ricardo; Posse, Stefan; Lin, Yi-Ru; Chung, Hsiao-Wen; Wald, Lawrence L; Wiggins, Graham C; Lin, Fa-Hsuan

    2008-05-01

    Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm(3) voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared to an 8-channel array, the smaller RF coil elements in this 32-channel array provided a 3.1-fold and 2.8-fold increase in signal-to-noise ratio (SNR) in the peripheral region and the central region, respectively, and more spatial modulated information. Comparison of sensitivity-encoding (SENSE) and GRAPPA reconstruction using an 8-channel array showed that both methods yielded similar quantitative metabolite measures (P > 0.1). Concentration values of N-acetyl-aspartate (NAA), total creatine (tCr), choline (Cho), myo-inositol (mI), and the sum of glutamate and glutamine (Glx) for both methods were consistent with previous studies. Using the 32-channel array coil the mean Cramer-Rao lower bounds (CRLB) were less than 8% for NAA, tCr, and Cho and less than 15% for mI and Glx at 2-fold acceleration. At 4-fold acceleration the mean CRLB for NAA, tCr, and Cho was less than 11%. In conclusion, the use of a 32-channel coil array and GRAPPA reconstruction can significantly reduce the measurement time for mapping brain metabolites.

  19. A technique for epoxy free winding and assembly of cos. theta. coils for accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Carson, J.A.; Bossert, R.

    1986-09-30

    Traditional methods of magnet construction (wet winding) use molded coil subassemblies bonded together with epoxy impregnated fiberglass tape. This is a highly labor intensive process involving redundant operations for each of the four coils. The epoxy free winding technique (dry winding) eliminates the epoxy curing steps and also allows all four coils to be wound on 3 common winding mandrel, thereby reducing winding stations and handling. The tooling required for dry winding is a radical departure from existing technology imposing new mechanical problems. A number of 64 cm long 5 cm aperture SSC Design B'' magnets have been produced at Fermilab utilizing dry winding techniques. Discussed is the specialized tooling created to accomplish dry winding as well as new winding and assembly procedures required. Also discussed are mechanical problems encountered and their solutions. Based on experience gained, dry winding can be a viable lower cost alternative to traditional coil fabrication techniques.

  20. Hawking radiation of scalar particles from accelerating and rotating black holes

    Energy Technology Data Exchange (ETDEWEB)

    Gillani, Usman A.; Rehman, Mudassar; Saifullah, K., E-mail: mani_precious2001@yahoo.com, E-mail: mudassar051@yahoo.com, E-mail: saifullah@qau.edu.pk [Department of Mathematics, Quaid-i-Azam University, Islamabad (Pakistan)

    2011-06-01

    Hawking radiation of uncharged and charged scalar particles from accelerating and rotating black holes is studied. We calculate the tunneling probabilities of these particles from the rotation and acceleration horizons of these black holes. Using this method we recover the correct Hawking temperature as well.

  1. Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    Science.gov (United States)

    Tam, Leo K; Stockmann, Jason P; Galiana, Gigi; Constable, R Todd

    2012-10-01

    To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic field encoding gradients are designed to encode spatial information where receiver spatial encoding is ambiguous, for example, along sensitivity isocontours. Specifically, the method generates a basis set for the null space of the coil sensitivities with the singular value decomposition and calculates encoding fields from the null space vectors. A set of nonlinear gradients is used as projection imaging readout magnetic fields, replacing the conventional linear readout field and phase encoding. Multiple encoding fields are used as projections to capture the null space information, hence the term null space imaging. The method is compared to conventional Cartesian SENSitivity Encoding as evaluated by mean squared error and robustness to noise. Strategies for developments in the area of nonlinear encoding schemes are discussed. The null space imaging approach yields a parallel imaging method that provides high acceleration factors with a limited number of receiver coil array elements through increased time efficiency in spatial encoding.

  2. Numerical Analysis of Rotating Pumping Flows in Inter-Coil Rotor Cavities and Short Cooling Grooves of a Generator

    Directory of Open Access Journals (Sweden)

    Wei Tong

    2001-01-01

    Full Text Available An important characteristic of wall rotating-driven flows is the tendency of fluid with high angular momentum to be flung radially outward. For a generator, the rotor rotating-driven flow, usually referred to as the rotating pumping flow, plays an important role in rotor winding cooling. In this study, three-dimensional numerical analyzes are presented for turbulent pumping flow in the inter-coil rotor cavity and short cooling grooves of a generator. Calculations of the flow field and the mass flux distribution through the grooves were carried out in a sequence of four related cases Under an isothermal condition: (a pumping flow, which is the self-generated flow resulted from the rotor pumping action; (b mixing flow, which is the combination of the ventilating flow and pumping flow, under a constant density condition; (c mixing flow, with density modeled by the ideal gas law; and (d mixing flow, with different pressure differentials applied on the system. The comparisons of the results from these cases can provide useful information regarding the impacts of the ventilating flow, gas density, and system pressure differential on the mass flux distribution in the short cooling grooves. Results show that the pumping effect is strong enough to generate the cooling flow for rotor winding cooling. Therefore, for small- or mid-size generators ventilation fans may be eliminated. It also suggests that increasing the chimney dimension can improve the distribution uniformity of mass flux through the cooling grooves.

  3. Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques

    Science.gov (United States)

    MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an under-mat. For Osoto-gari, peak resultant rotational acceleration ranged from 4,284.2 rad/s2 to 5,525.9 rad/s2 and peak resultant translational acceleration ranged from 64.3 g to 87.2 g; for Ouchi-gari, the accelerations respectively ranged from 1,708.0 rad/s2 to 2,104.1 rad/s2 and from 120.2 g to 149.4 g. The resultant rotational acceleration did not decrease with installation of an under-mat for both Ouchi-gari and Osoto-gari. We found that head contact with the tatami could result in the peak values of translational and rotational accelerations, respectively. In general, because kinematics of the body strongly affects translational and rotational accelerations of the head, both accelerations should be measured to analyze the underlying mechanism of head injury. As a primary preventative measure, throwing techniques should be restricted to participants demonstrating ability in ukemi techniques to avoid head contact with the tatami. PMID:24477065

  4. Rotating Charged Hairy Black Hole in (2+1) Dimensions and Particle Acceleration

    Science.gov (United States)

    Sadeghi, J.; Pourhassan, B.; Farahani, H.

    2014-09-01

    In this paper, we construct rotating charged hairy black hole in (2+1) dimensions for infinitesimal black hole charge and rotation parameters. Then we consider this black hole as particle accelerator and calculate the center-of-mass energy of two colliding test particles near the rotating charged hairy black hole in (2+1) dimensions. As we expected, the center-of-mass energy has infinite value.

  5. Rotating charged hairy black hole in (2+1) dimensions and particle acceleration

    CERN Document Server

    Sadeghi, J; Farahani, H

    2013-01-01

    In this paper we construct rotating charged hairy black hole in (2+1) dimensions for infinitesimal black hole charge and rotation parameters. Then we consider this black hole as particle accelerator and calculate the center-of-mass energy of two colliding test particles near the rotating charged hairy black hole in (2+1) dimensions. As we expected, the center-of-mass energy has infinite value.

  6. A Novel Idea for Coil Collar Structures in Accelerator Superconducting Magnets

    CERN Document Server

    Fessia, P

    2002-01-01

    The dipoles for several different machines (LHC, SSC, HERA) were designed using non-magnetic metallic collars to contain the superconducting coils. The coils are of two types, main and floating. This paper describes a structure with combined steel and plastic collars. Since the floating collars do not give an important contribution to the global rigidity of the dipole we propose to suppress them. The plastic collars are just fillers to limit the helium contained in the cold mass. Some data about thermoplastic materials to be possibly used for the collars are given and some estimations of mass and cost of this configuration are made. Finally the results of the tests of a 1-m-long twin aperture dipole with mixed steel-plastic collars are shortly described. The replacement of expensive alloys by high performance plastic in non-structural components can be a cost-effective solution in view of future projects where superconducting magnets are involved and contained costs are a key issue.

  7. Chaotic motion of particles in the accelerating and rotating black holes spacetime

    CERN Document Server

    Chen, Songbai; Jing, Jiliang

    2016-01-01

    We have investigated the motion of timelike particles along geodesic in the background of accelerating and rotating black hole spacetime. We confirmed that the chaos exists in the geodesic motion of the particles by Poincar\\'e sections, the power spectrum, the fast Lyapunov exponent indicator and the bifurcation diagram. Moreover, we probe the effects of the acceleration and rotation parameters on the chaotic behavior of a timelike geodesic particle in the black hole spacetime. Our results show that the acceleration brings richer physics for the geodesic motion of particles.

  8. Snakes and spin rotators for high energy accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.Y. (Indiana Univ., Bloomington, IN (USA). Dept. of Physics)

    1991-08-15

    A modification to the continuous family of snake and spin rotators, discovered by Steffen, is discussed. A compact snake configuration is found to have the advantages of requiring a smaller total integrated dipole magnet strength and a smaller transverse displacement for circulating particles. A split snake configuration has the advantage of allowing an entire experimental insertion region to be located between the two halves of the snake. Such configuration could serve as both a snake and a 90deg spin rotator for experiments requiring different helicity states. General properties of these snake configurations are discussed. (orig.).

  9. A novel no-insulation winding technique of high temperature-superconducting racetrack coil for rotating applications: A progress report in Korea university

    Science.gov (United States)

    Choi, Y. H.; Song, J. B.; Yang, D. G.; Kim, Y. G.; Hahn, S.; Lee, H. G.

    2016-10-01

    This paper presents our recent progress on core technology development for a megawatt-class superconducting wind turbine generator supported by the international collaborative R&D program of the Korea Institute of Energy Technology Evaluation and Planning. To outperform the current high-temperature-superconducting (HTS) magnet technology in the wind turbine industry, a novel no-insulation winding technique was first proposed to develop the second-generation HTS racetrack coil for rotating applications. Here, we briefly report our recent studies on no-insulation (NI) winding technique for GdBCO coated conductor racetrack coils in the following areas: (1) Charging-discharging characteristics of no-insulation GdBCO racetrack coils with respect to external pressures applied to straight sections; (2) thermal and electrical stabilities of no-insulation GdBCO racetrack coils encapsulated with various impregnating materials; (3) quench behaviors of no-insulation racetrack coils wound with GdBCO conductor possessing various lamination layers; (4) electromagnetic characteristics of no-insulation GdBCO racetrack coils under time-varying field conditions. Test results confirmed that this novel NI winding technique was highly promising. It could provide development of a compact, mechanically dense, and self-protecting GdBCO magnet for use in real-world superconducting wind turbine generators.

  10. Mechanical Effects of the Non-Uniform Current Distribution on HTS Coils for Accelerators Wound with REBCO Roebel Cable

    CERN Document Server

    Murtomaeki, Jaako; Kirby, Glen; Rossi, Lucio; Ruuskanen, Janne; Stenvall, Antti; Murtomaeki, Jaako

    2017-01-01

    Future high-energy accelerators will need very high magnetic fields in the range of 20 T. The EuCARD-2 WP10 Future Magnets collaboration is aiming at testing HTS-based Roebel cables in an accelerator magnet. The demonstrator should produce around 17 T, when inserted into the 100 mm aperture of Feather-M2 13 T outsert magnet. HTS Roebel cables are assembled from meander shaped REBCO coated conductor tapes. In comparison with fair level of uniformity of current distribution in cables made out of round Nb-Ti or Nb3Sn strands, current distribution within the coils wound from Roebel cables is highly non-homogeneous. It results in nonuniform electromagnetic force distribution over the cable that could damage the very thin REBCO superconducting layer. This paper focuses on the numerical models to describe the effect of the non-homogenous current distribution on stress distribution in the demonstrator magnet designed for the EuCARD-2 project. Preliminary results indicate that the impregnation bonding betweenthecable...

  11. Continuous-flow fractionation of selenium in contaminated sediment and soil samples using rotating coiled column and microcolumn extraction.

    Science.gov (United States)

    Savonina, Elena Yu; Fedotov, Petr S; Wennrich, Rainer

    2012-01-15

    Dynamic fractionation is considered to be an attractive alternative to conventional batch sequential extraction procedures for partitioning of trace metals and metalloids in environmental solid samples. This paper reports the first results on the continuous-flow dynamic fractionation of selenium using two different extraction systems, a microcolumn (MC) packed with the solid sample and a rotating coiled column (RCC) in which the particulate matter is retained under the action of centrifugal forces. The eluents (leachants) were applied in correspondence with a four-step sequential extraction scheme for selenium addressing "soluble", "adsorbed", "organically bound", and "elemental" Se fractions extractable by distilled water, phosphate buffer, tetramethylammonium hydroxide, and sodium sulphite solutions, respectively. Selenium was determined in the effluent by using an inductively coupled plasma atomic emission spectrometer. Contaminated creek sediment and dumped waste (soil) samples from the abandoned mining area were used to evaluate resemblances and discrepancies of two continuous-flow methods for Se fractionation. In general, similar trends were found for Se distribution between extractable and residual fractions. However, for the dumped waste sample which is rich in organic matter, the extraction in RCC provided more effective recovery of environmentally relevant Se forms (the first three leachable fractions). The most evident deviation was observed for "adsorbed" Se (recoveries by RCC and MC are 43 and 7 mg kg(-1), respectively). The data obtained were correlated with peculiarities of samples under investigation and operational principles of RCC and MC.

  12. Accelerated short-TE 3D proton echo-planar spectroscopic imaging using 2D-SENSE with a 32-channel array coil.

    Science.gov (United States)

    Otazo, Ricardo; Tsai, Shang-Yueh; Lin, Fa-Hsuan; Posse, Stefan

    2007-12-01

    MR spectroscopic imaging (MRSI) with whole brain coverage in clinically feasible acquisition times still remains a major challenge. A combination of MRSI with parallel imaging has shown promise to reduce the long encoding times and 2D acceleration with a large array coil is expected to provide high acceleration capability. In this work a very high-speed method for 3D-MRSI based on the combination of proton echo planar spectroscopic imaging (PEPSI) with regularized 2D-SENSE reconstruction is developed. Regularization was performed by constraining the singular value decomposition of the encoding matrix to reduce the effect of low-value and overlapped coil sensitivities. The effects of spectral heterogeneity and discontinuities in coil sensitivity across the spectroscopic voxels were minimized by unaliasing the point spread function. As a result the contamination from extracranial lipids was reduced 1.6-fold on average compared to standard SENSE. We show that the acquisition of short-TE (15 ms) 3D-PEPSI at 3 T with a 32 x 32 x 8 spatial matrix using a 32-channel array coil can be accelerated 8-fold (R = 4 x 2) along y-z to achieve a minimum acquisition time of 1 min. Maps of the concentrations of N-acetyl-aspartate, creatine, choline, and glutamate were obtained with moderate reduction in spatial-spectral quality. The short acquisition time makes the method suitable for volumetric metabolite mapping in clinical studies.

  13. Equatorial gravitational lensing by accelerating and rotating black hole with NUT parameter

    Science.gov (United States)

    Sharif, M.; Iftikhar, Sehrish

    2016-01-01

    This paper is devoted to study equatorial gravitational lensing in accelerating and rotating black hole with a NUT parameter in the strong field limit. For this purpose, we first calculate null geodesic equation using the Hamilton-Jacobi separation method. We then numerically obtain deflection angle and deflection coefficients which depend on acceleration and spin parameter of the black hole. We also investigate observables in the strong field limit by taking the example of a black hole in the center of galaxy. It is concluded that acceleration parameter has a significant effect on the strong field lensing in the equatorial plane.

  14. Clinical and multidetector CT follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Min; Park, Kwang Bo; Kim, Keon Ha; Jeon, Pyoung; Shin, Sung Wook; Park, Hong Suk; Do, Young Soo (Dept. of Radiology and the Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kbparksmc@skku.edu; Kim, Dong-Ik; Kim, Young-Wook (Div. of Vascular Surgery, Dept. of Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of))

    2011-10-15

    Background: There are very few reports regarding the use of 3D rotational angiography (3D RA) in embolization of renal artery aneurysms (RAAs). No valuable data have been reported on the follow-up result of coil embolization for RAAs on computed tomography (CT). Purpose: To evaluate the clinical and multidetector computed tomography (MDCT) follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D RA. Material and Methods: Six patients diagnosed with RAAs were included. Five patients underwent detachable coil embolization. Five patients underwent 3D RA and the parameters used for planning endovascular treatment obtained by 2D CT, reformatted 3D CT angiography (3D CTA), 2D digital subtraction angiography (2D DSA) and 3D RA were compared. The post embolization MDCT follow-up findings were analyzed retrospectively. Results: The technical success rate for detachable coil embolization was 40%. The 3D CTA showed the dome-to-neck ratio (DNR) and tangential view of the renal artery aneurysm in five patients (83.3%) and the 2D CT showed it in four (66.7%). An optimal working angle assessment could not be obtained on the 2D CT and 3D CTA. The 3D RA showed the DNR, tangential view, and optimal working angle in all patients. Renal infarction occurred in three patients and Postprocedural hypertension developed in two patients during the follow-up period. Conclusion: The 3D RA was useful in preoperative determination of adequate working angle for detachable coil embolization of RAAs. Late complications of detachable coil embolization for RAAs were renal infarction and hypertension

  15. Two algorithms of working acceleration generated by a precision centrifuge with two rotating axes

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The displacement of the origin of the accelerometer coordinate system relative to the origin of the base coordinate system is calculated by homogeneous transformation. The second order derivative of this displacement is the acceleration of the origin to the accelerometer coordinate system. By means of the attitude relationship between the base coordinate system and the accelerometer coordinate system, the acceleration components on the three coordinate axes is obtained. Utilizing the Coriolis rotation coordinate theorem, the three components are also calculated. The homogeneous transformation method and vector differential method lead to identical results.

  16. Localization, quantum resonances, and ratchet acceleration in a periodically kicked PT -symmetric quantum rotator

    Science.gov (United States)

    Longhi, Stefano

    2017-01-01

    We consider wave transport phenomena in a PT -symmetric extension of the periodically kicked quantum rotator model and reveal that dynamical localization assists the unbroken PT phase. In the delocalized (quantum resonance) regime, PT symmetry is always in the broken phase and ratchet acceleration arises as a signature of unidirectional non-Hermitian transport. An optical implementation of the periodically kicked PT -symmetric Hamiltonian, based on transverse beam propagation in a passive optical resonator with combined phase and loss gratings, is suggested to visualize acceleration modes in fractional Talbot cavities.

  17. Liquid rope coiling

    NARCIS (Netherlands)

    N.M. Ribe; M. Habibi; D. Bonn

    2012-01-01

    A thin stream or rope of viscous fluid falling from a sufficient height onto a surface forms a steadily rotating helical coil. Tabletop laboratory experiments in combination with a numerical model for slender liquid ropes reveal that finite-amplitude coiling can occur in four distinct regimes (visco

  18. Accelerated micropolar fluid-flow past an uniformly rotating circular cylinder

    Science.gov (United States)

    Siddiqui, Abuzar Abid

    2016-10-01

    In this paper, we formulated the non-steady flow due to the uniformly accelerated and rotating circular cylinder from rest in a stationary, viscous, incompressible and micropolar fluid. This flow problem is examined numerically by adopting a special scheme comprising the Adams-Bashforth Temporal Fourier Series method and the Runge-Kutta Temporal Special Finite-Difference method. This numerical scheme transforms the governing equation into a system of finite-difference equations. This system was further solved numerically by point successive-over-relaxation method. These results were also further extrapolated by the Richardson extrapolation method. This scheme is valid for all values of the flow and fluid-parameters and for all time. Moreover the boundary conditions of the vorticity and the spin at points far from the cylinder are being imposed and encountered too. The results are compared with existing results (for non-rotating circular cylinder in Newtonian fluids). The comparison is good. The enhancement of lift and reduction in drag is observed if the micropolarity effects are intensified. Same is happened if the rotation of a cylinder increases. Furthermore, the vortex-pair in the wake is delayed to successively higher times as rotation parameter increases. In addition, the rotation helps not only in dissolving vortices adjacent to the cylinder and adverse pressure region but also in dissolving the boundary layer separation. Furthermore, the rotation reduces the micropolar spin boundary layer.

  19. Accelerated micropolar fluid–flow past an uniformly rotating circular cylinder

    Directory of Open Access Journals (Sweden)

    Abuzar Abid Siddiqui

    2016-10-01

    Full Text Available In this paper, we formulated the non-steady flow due to the uniformly accelerated and rotating circular cylinder from rest in a stationary, viscous, incompressible and micropolar fluid. This flow problem is examined numerically by adopting a special scheme comprising the Adams-Bashforth Temporal Fourier Series method and the Runge-Kutta Temporal Special Finite-Difference method. This numerical scheme transforms the governing equation into a system of finite-difference equations. This system was further solved numerically by point successive-over-relaxation method. These results were also further extrapolated by the Richardson extrapolation method. This scheme is valid for all values of the flow and fluid-parameters and for all time. Moreover the boundary conditions of the vorticity and the spin at points far from the cylinder are being imposed and encountered too. The results are compared with existing results (for non-rotating circular cylinder in Newtonian fluids. The comparison is good. The enhancement of lift and reduction in drag is observed if the micropolarity effects are intensified. Same is happened if the rotation of a cylinder increases. Furthermore, the vortex-pair in the wake is delayed to successively higher times as rotation parameter increases. In addition, the rotation helps not only in dissolving vortices adjacent to the cylinder and adverse pressure region but also in dissolving the boundary layer separation. Furthermore, the rotation reduces the micropolar spin boundary layer.

  20. The SMC (Short Model Coil) dipole: An R&D program for Nb3Sn accelerator magnets

    CERN Document Server

    Perez, J C; Bordini, B; Canfer, S; Ellwood, G; Feuvrier, J; Guinchard, M; Karppinen, M; Kokkinos, C; Manil, P; Milanese, A; Oberli, L; Regis, F; de Rijk, G

    2012-01-01

    The Short Model Coil (SMC) assembly has been designed, as test bench for short racetrack coils wound with Nb3Sn cable. The mechanical structure comprises an iron yoke surrounded by a 20 mm thick aluminium alloy shell, and includes four loading pads that transmit the required pre-compression from the outer shell into the two coils. The outer shell is pre-tensioned with mechanical keys that are inserted with the help of pressurized bladders and two 30 mm diameter aluminium alloy rods provide the axial loading to the coil ends. The outer shell, the axial rods, and the coils are instrumented with strain gauges, which allow precise monitoring of the loading conditions during the assembly and at cryogenic temperature during the magnet test. Two SMC assemblies have been completed and cold tested in the frame of a European collaboration between CEA (FR), CERN and STFC (UK) and with the technical support from LBNL (US). This paper describes the main features of the SMC assembly, the experience from the dummy assembli...

  1. The Short Model Coil (SMC) dipole: an R&D program towards Nb3Sn accelerator magnets

    CERN Document Server

    Bajko, M; Canfer, S; Ellwood, G; Feuvrier, J; Guinchard, M; Karppinen, M; Kokkinos, C; Manil, P; Milanese, A; Oberli, L; Perez, J-C; Regis, F; de Rijk, G

    2011-01-01

    The Short Model Coil (SMC) assembly has been designed, as test bench for short racetrack coils wound with Nb3Sn cable. The mechanical structure comprises an iron yoke surrounded by a 20 mm thick aluminium alloy shell, and includes four loading pads that transmit the required pre-compression from the outer shell into the two coils. The outer shell is pre-tensioned with mechanical keys that are inserted with the help of pressurized bladders and two 30 mm diameter aluminium alloy rods provide the axial loading to the coil ends. The outer shell, the axial rods, and the coils are instrumented with strain gauges, which allow precise monitoring of the loading conditions during the assembly and at cryogenic temperature during the magnet test. Two SMC assemblies have been completed and cold tested in the frame of a European collaboration between CEA (FR), CERN and STFC (UK) and with the technical support from LBNL (US). This paper describes the main features of the SMC assembly, the experience from the dummy assemblie...

  2. MASS TRANSFER EFFECTS ON ACCELERATED VERTICAL PLATE IN A ROTATING FLUID WITH FIRST ORDER CHEMICAL REACTION

    Directory of Open Access Journals (Sweden)

    R. Muthucumaraswamy

    2012-12-01

    Full Text Available The precise analysis of the rotation effects on the unsteady flow of an incompressible fluid past a uniformly accelerated infinite vertical plate with variable temperature and mass diffusion has been undertaken, in the presence of a homogeneous first order chemical reaction. The dimensionless governing equations are solved using the Laplace-transform technique. The plate temperature as well as the concentration near the plate increase linearly with time. The velocity profiles, temperature and concentration are studied for different physical parameters, like the chemical reaction parameter, thermal Grashof number, mass Grashof number, Schmidt number, Prandtl number and time. It is observed that the velocity increases with increasing values of thermal Grashof number or mass Grashof number. It is also observed that the velocity increases with decreasing rotation parameter Ω.

  3. Accelerated micropolar fluid--flow past an uniformly rotating circular cylinder

    CERN Document Server

    Siddiqui, Abuzar Abid

    2016-01-01

    In this paper, we formulated the non-steady flow due to the uniformly accelerated and rotating circular cylinder from rest in a stationary, viscous, incompressible and micropolar fluid. This flow problem is examined numerically by adopting a special scheme comprising the Adams-Bashforth Temporal Fourier Series method and the Runge-Kutta Temporal Special Finite-Difference method. This numerical scheme transforms the governing equation for micropolar fluids for this problem into system of finite-difference equations. This system was further solved numerically by point SOR-method. These results were also further extrapolated by the Richardson extrapolation method. This scheme is valid for all values of the flow and fluid-parameters and for all time. Moreover the boundary conditions of the vorticity and the spin at points far from the cylinder are being imposed and encountered too. The results are compared with existing results (for non-rotating circular cylinder in Newtonian fluids). The comparison is good. The ...

  4. Aerodynamics in the amusement park: interpreting sensor data for acceleration and rotation

    Science.gov (United States)

    Löfstrand, Marcus; Pendrill, Ann-Marie

    2016-09-01

    The sky roller ride depends on interaction with the air to create a rolling motion. In this paper, we analyse forces, torque and angular velocities during different parts of the ride, combining a theoretical analysis, with photos, videos as well as with accelerometer and gyroscopic data, that may be collected e.g. with a smartphone. For interpreting the result, it must be taken into account that the sensors and their coordinate system rotate together with the rider. The sky roller offers many examples for physics education, from simple circular motion, to acceleration and rotation involving several axes, as well as the relation between wing orientation, torque and angular velocities and using barometer pressure to determine the elevation gain.

  5. Hall Effects on Unsteady Hydromagnetic Flow Past an Accelerated Porous Plate in a Rotating System

    Directory of Open Access Journals (Sweden)

    Sanatan Das

    2015-01-01

    Full Text Available An unsteady hydromagnetic flow of a viscous incompressible electrically conducting fluid past an accelerated porous flat plate in the presence of a uniform transverse magnetic field in a rotating system taking the Hall effects into account have been presented. An analytical solution describing the flow at large and small times after the start is obtained by the use of Laplace transform technique. The influences of the physical parameters acting on the flow are discussed in detail with the help of several graphs. It is found that interplay of Coriolis force and hydromagnetic force in the presence of Hall currents plays an important role in characterizing the flow behavior.

  6. Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. I. Normal responses

    Science.gov (United States)

    Minor, L. B.; Lasker, D. M.; Backous, D. D.; Hullar, T. E.; Shelhamer, M. J. (Principal Investigator)

    1999-01-01

    The horizontal angular vestibuloocular reflex (VOR) evoked by high-frequency, high-acceleration rotations was studied in five squirrel monkeys with intact vestibular function. The VOR evoked by steps of acceleration in darkness (3,000 degrees /s(2) reaching a velocity of 150 degrees /s) began after a latency of 7.3 +/- 1.5 ms (mean +/- SD). Gain of the reflex during the acceleration was 14.2 +/- 5.2% greater than that measured once the plateau head velocity had been reached. A polynomial regression was used to analyze the trajectory of the responses to steps of acceleration. A better representation of the data was obtained from a polynomial that included a cubic term in contrast to an exclusively linear fit. For sinusoidal rotations of 0.5-15 Hz with a peak velocity of 20 degrees /s, the VOR gain measured 0.83 +/- 0.06 and did not vary across frequencies or animals. The phase of these responses was close to compensatory except at 15 Hz where a lag of 5.0 +/- 0.9 degrees was noted. The VOR gain did not vary with head velocity at 0.5 Hz but increased with velocity for rotations at frequencies of >/=4 Hz (0. 85 +/- 0.04 at 4 Hz, 20 degrees /s; 1.01 +/- 0.05 at 100 degrees /s, P < 0.0001). No responses to these rotations were noted in two animals that had undergone bilateral labyrinthectomy indicating that inertia of the eye had a negligible effect for these stimuli. We developed a mathematical model of VOR dynamics to account for these findings. The inputs to the reflex come from linear and nonlinear pathways. The linear pathway is responsible for the constant gain across frequencies at peak head velocity of 20 degrees /s and also for the phase lag at higher frequencies being less than that expected based on the reflex delay. The frequency- and velocity-dependent nonlinearity in VOR gain is accounted for by the dynamics of the nonlinear pathway. A transfer function that increases the gain of this pathway with frequency and a term related to the third power of head

  7. Entropy bound of horizons for accelerating, rotating and charged Plebanski-Demianski black hole

    Science.gov (United States)

    Debnath, Ujjal

    2016-09-01

    We first review the accelerating, rotating and charged Plebanski-Demianski (PD) black hole, which includes the Kerr-Newman rotating black hole and the Taub-NUT spacetime. The main feature of this black hole is that it has 4 horizons like event horizon, Cauchy horizon and two accelerating horizons. In the non-extremal case, the surface area, entropy, surface gravity, temperature, angular velocity, Komar energy and irreducible mass on the event horizon and Cauchy horizon are presented for PD black hole. The entropy product, temperature product, Komar energy product and irreducible mass product have been found for event horizon and Cauchy horizon. Also their sums are found for both horizons. All these relations are dependent on the mass of the PD black hole and other parameters. So all the products are not universal for PD black hole. The entropy and area bounds for two horizons have been investigated. Also we found the Christodoulou-Ruffini mass for extremal PD black hole. Finally, using first law of thermodynamics, we also found the Smarr relation for PD black hole.

  8. Entropy Bound of Horizons for Accelerating, Rotating and Charged Plebanski-Demianski Black Hole

    CERN Document Server

    Debnath, Ujjal

    2015-01-01

    We first review the accelerating, rotating and charged Plebanski-Demianski (PD) black hole, which includes the Kerr-Newman rotating black hole and the Taub-NUT spacetime. The main feature of this black hole is that it has 4 horizons like event horizon, Cauchy horizon and two accelerating horizons. In the non-extremal case, the surface area, entropy, surface gravity, temperature, angular velocity, Komar energy and irreducible mass on the event horizon and Cauchy horizon are presented for PD black hole. The entropy product, temperature product, Komar energy product and irreducible mass product are found for event horizon and Cauchy horizon. Also their sums are also found for both horizons. All these relations are found to be depend on mass of the PD black hole and other parameters. So all the products are not universal for PD black hole. The entropy and area bounds for two horizons are investigated. Also we found the Christodoulou-Ruffini mass for extremal PD black hole. Finally, using first law of thermodynami...

  9. Jet magnetically accelerated from disk-corona around a rotating black hole

    CERN Document Server

    Gong, Xiaolong

    2012-01-01

    A jet acceleration model for extracting energy from disk-corona surrounding a rotating black hole is proposed. In the disk-corona scenario, we obtain the ratio of the power dissipated in the corona to the total for such disk-corona system by solving the disk dynamics equations. The analytical expression of the jet power is derived based on the electronic circuit theory of the magnetosphere. It is shown that jet power increases with the increasing black hole (BH) spin, and concentrates in the inner region of the disk-corona. In addition, we use a sample consisting of 37 radio loud quasars to explore their jet production mechanism, and show that our jet formation mechanism can simulate almost all sources with high power jet, that fail to be explained by the Blandford-Znajek (BZ) process.

  10. Coupled inertial and gravitational effects in the proper reference frame of an accelerated, rotating observer

    Energy Technology Data Exchange (ETDEWEB)

    Li, W.; Ni, W.

    1979-07-01

    To the second order in metric and the first order in equations of motion in the local coordinates of an accelerated rotating observer, the inertial effects and gravitational effects are simply additive. To look into the coupled inertial and gravitational effects, we derive the third-order expansion of the metric and the second-order expansion of the equations of motion in local coordinates. Besides purely gravitational (purely curvature) effects, the equations of motion contain, in this order, the following coupled inertial and gravitational effects: redshift corrections to electric, magnetic, and double-magnetic type curvature forces; velocity-induced special relativistic corrections; and electric, magnetic, and double-magnetic type coupled inertial and gravitational forces. An example is provided with a static observer in the Schwarzchild spacetime.

  11. Jet magnetically accelerated from disk-corona around a rotating black hole

    Institute of Scientific and Technical Information of China (English)

    GONG XiaoLong; LI LiXin

    2012-01-01

    A jet acceleration model for extracting energy from disk-corona surrounding a rotating black hole (BH) is proposed.In the diskcorona scenario,we obtain the ratio of the power dissipated in the corona to the total for such disk-corona system by solving the disk dynamics equations.The analytical expression of the jet power is derived based on the electronic circuit theory of the magnetosphere.It is shown that jet power increases with the increasing BH spin,and concentrates in the inner region of the disk-corona.In addition,we use a sample consisting of 37 radio loud quasars to explore their jet production mechanism,and show that our jet formation mechanism can simulate almost all sources with high power jet,which fails to be explained by the Blandford-Znajek (BZ) process.

  12. Short Rotations in Forest Plantations Accelerate Virulence Evolution in Root-Rot Pathogenic Fungi

    Directory of Open Access Journals (Sweden)

    Jean-Paul Soularue

    2017-06-01

    Full Text Available As disease outbreaks in forest plantations are causing concern worldwide, a clear understanding of the influence of silvicultural practices on the development of epidemics is still lacking. Importantly, silvicultural practices are likely to simultaneously affect epidemiological and evolutionary dynamics of pathogen populations. We propose a genetically explicit and individual-based model of virulence evolution in a root-rot pathogenic fungus spreading across forest landscapes, taking the Armillaria ostoyae–Pinus pinaster pathosystem as reference. We used the model to study the effects of rotation length on the evolution of virulence and the propagation of the fungus within a forest landscape composed of even-aged stands regularly altered by clear-cutting and thinning operations. The life cycle of the fungus modeled combines asexual and sexual reproduction modes, and also includes parasitic and saprotrophic phases. Moreover, the tree susceptibility to the pathogen is primarily determined by the age of the stand. Our simulations indicated that the shortest rotation length accelerated both the evolution of virulence and the development of the epidemics, whatever the genetic variability in the initial fungal population and the asexuality rate of the fungal species

  13. Revolution rather than rotation of AAA+ hexameric phi29 nanomotor for viral dsDNA packaging without coiling.

    Science.gov (United States)

    Schwartz, Chad; De Donatis, Gian Marco; Zhang, Hui; Fang, Huaming; Guo, Peixuan

    2013-08-15

    It has long been believed that the DNA-packaging motor of dsDNA viruses utilizes a rotation mechanism. Here we report a revolution rather than rotation mechanism for the bacteriophage phi29 DNA packaging motor. The phi29 motor contains six copies of the ATPase (Schwartz et al., this issue); ATP binding to one ATPase subunit stimulates the ATPase to adopt a conformation with a high affinity for dsDNA. ATP hydrolysis induces a new conformation with a lower affinity, thus transferring the dsDNA to an adjacent subunit by a power stroke. DNA revolves unidirectionally along the hexameric channel wall of the ATPase, but neither the dsDNA nor the ATPase itself rotates along its own axis. One ATP is hydrolyzed in each transitional step, and six ATPs are consumed for one helical turn of 360°. Transition of the same dsDNA chain along the channel wall, but at a location 60° different from the last contact, urges dsDNA to move forward 1.75 base pairs each step (10.5bp per turn/6ATP=1.75bp per ATP). Each connector subunit tilts with a left-handed orientation at a 30° angle in relation to its vertical axis that runs anti-parallel to the right-handed dsDNA helix, facilitating the one-way traffic of dsDNA. The connector channel has been shown to cause four steps of transition due to four positively charged lysine rings that make direct contact with the negatively charged DNA phosphate backbone. Translocation of dsDNA into the procapsid by revolution avoids the difficulties during rotation that are associated with DNA supercoiling. Since the revolution mechanism can apply to any stoichiometry, this motor mechanism might reconcile the stoichiometry discrepancy in many phage systems where the ATPase has been found as a tetramer, hexamer, or nonamer. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  14. α/β coiled coils.

    Science.gov (United States)

    Hartmann, Marcus D; Mendler, Claudia T; Bassler, Jens; Karamichali, Ioanna; Ridderbusch, Oswin; Lupas, Andrei N; Hernandez Alvarez, Birte

    2016-01-15

    Coiled coils are the best-understood protein fold, as their backbone structure can uniquely be described by parametric equations. This level of understanding has allowed their manipulation in unprecedented detail. They do not seem a likely source of surprises, yet we describe here the unexpected formation of a new type of fiber by the simple insertion of two or six residues into the underlying heptad repeat of a parallel, trimeric coiled coil. These insertions strain the supercoil to the breaking point, causing the local formation of short β-strands, which move the path of the chain by 120° around the trimer axis. The result is an α/β coiled coil, which retains only one backbone hydrogen bond per repeat unit from the parent coiled coil. Our results show that a substantially novel backbone structure is possible within the allowed regions of the Ramachandran space with only minor mutations to a known fold.

  15. Responses to rotating linear acceleration vectors considered in relation to a model of the otolith organs. [human oculomotor response to transverse acceleration stress

    Science.gov (United States)

    Benson, A. J.; Barnes, G. R.

    1973-01-01

    Human subjects were exposed to a linear acceleration vector that rotated in the transverse plane of the skull without angular counterrotation. Lateral eye movements showed a sinusoidal change in slow phase velocity and an asymmetry or bias in the same direction as vector rotation. A model is developed that attributes the oculomotor response to otolithic mechanisms. It is suggested that the bias component is the manifestation of torsion of the statoconial plaque relative to the base of the utricular macula and that the sinusoidal component represents the translational oscillation of the statoconia. The model subsumes a hypothetical neural mechanism which allows x- and y-axis accelerations to be resolved. Derivation of equations of motion for the statoconial plaque in torsion and translation, which take into account forces acting in shear and normal to the macula, yield estimates of bias and sinusoidal components that are in qualitative agreement with the diverse experimental findings.

  16. Hyaluronic Acid Accelerates Tendon-to-Bone Healing After Rotator Cuff Repair.

    Science.gov (United States)

    Honda, Hirokazu; Gotoh, Masafumi; Kanazawa, Tomonoshin; Ohzono, Hiroki; Nakamura, Hidehiro; Ohta, Keisuke; Nakamura, Kei-Ichiro; Fukuda, Kanji; Teramura, Takeshi; Hashimoto, Takashi; Shichijo, Shigeki; Shiba, Naoto

    2017-09-01

    tendon-to-bone healing in the rotator cuff repair model, enhancing the biomechanical strength and increasing chondroid formation and tendon maturity at the tendon-bone interface. Based on the data of in vitro experiments, HA-activated MSCs may play a crucial role in the acceleration of tendon-to-bone healing. The data suggest the relevance of clinical application of HA to accelerate tendon-to-bone healing. It may decrease the number of retears after surgery.

  17. Secular variation of earth's gravitational harmonic J2 coefficient from Lageos and nontidal acceleration of earth rotation

    Science.gov (United States)

    Yoder, C. F.; Williams, J. G.; Dickey, J. O.; Schutz, B. E.; Eanes, R. J.; Tapley, B. D.

    1983-01-01

    Analysis of 5.5 years of Lageos satellite range data reveal significant residual nodal signatures: an acceleration and annual and semiannual periods. These signatures primarily reflect variations in the zonal gravitational harmonic J2 coefficient and hence the polar moment of inertia. The implied decrease of J2 = -3 x 10 to the -11th/yr is consistent with both historical observations of the nontidal acceleration of the earth's rotation and models of viscous rebound of the solid earth from the decrease in load due to the last deglaciation.

  18. Localization, quantum resonances and ratchet acceleration in a periodically-kicked $\\mathcal{PT}$-symmetric quantum rotator

    CERN Document Server

    Longhi, Stefano

    2016-01-01

    We consider wave transport phenomena in a $\\mathcal{PT}$-symmetric extension of the periodically-kicked quantum rotator model and reveal that dynamical localization assists the unbroken $\\mathcal{PT}$ phase. In the delocalized (quantum resonance) regime, $\\mathcal{PT}$ symmetry is always in the broken phase and ratchet acceleration arises as a signature of unidirectional non-Hermitian transport. An optical implementation of the periodically-kicked $\\mathcal{PT}$-symmetric Hamiltonian, based on transverse beam propagation in a passive optical resonator with combined phase and loss gratings, is suggested to visualize acceleration modes in fractional Talbot cavities.

  19. Coiled-coil protein composition of 22 proteomes – differences and common themes in subcellular infrastructure and traffic control

    Directory of Open Access Journals (Sweden)

    Meier Iris

    2005-11-01

    Full Text Available Abstract Background Long alpha-helical coiled-coil proteins are involved in diverse organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems and tissues, motors, levers, rotating arms, and possibly springs. Mutations in long coiled-coil proteins have been implemented in a growing number of human diseases. Using the coiled-coil prediction program MultiCoil, we have previously identified all long coiled-coil proteins from the model plant Arabidopsis thaliana and have established a searchable Arabidopsis coiled-coil protein database. Results Here, we have identified all proteins with long coiled-coil domains from 21 additional fully sequenced genomes. Because regions predicted to form coiled-coils interfere with sequence homology determination, we have developed a sequence comparison and clustering strategy based on masking predicted coiled-coil domains. Comparing and grouping all long coiled-coil proteins from 22 genomes, the kingdom-specificity of coiled-coil protein families was determined. At the same time, a number of proteins with unknown function could be grouped with already characterized proteins from other organisms. Conclusion MultiCoil predicts proteins with extended coiled-coil domains (more than 250 amino acids to be largely absent from bacterial genomes, but present in archaea and eukaryotes. The structural maintenance of chromosomes proteins and their relatives are the only long coiled-coil protein family clearly conserved throughout all kingdoms, indicating their ancient nature. Motor proteins, membrane tethering and vesicle transport proteins are the dominant eukaryote-specific long coiled-coil proteins, suggesting that coiled-coil proteins have gained functions in the increasingly complex processes of subcellular infrastructure maintenance and trafficking control of the eukaryotic cell.

  20. Scaffolds, levers, rods and springs: diverse cellular functions of long coiled-coil proteins.

    Science.gov (United States)

    Rose, A; Meier, I

    2004-08-01

    Long alpha-helical coiled-coil proteins are involved in a variety of organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems, motors, levers, rotating arms and possibly springs. A growing number of human diseases are found to be caused by mutations in long coiled-coil proteins. This review summarizes our current understanding of the multifaceted group of long coiled-coil proteins in the cytoskeleton, nucleus, Golgi and cell division apparatus. The biophysical features of coiled-coil domains provide first clues toward their contribution to the diverse protein functions and promise potential future applications in the area of nanotechnology. Combining the power of fully sequenced genomes and structure prediction algorithms, it is now possible to comprehensively summarize and compare the complete inventory of coiled-coil proteins of different organisms.

  1. Conformal Transformations, Rotating String and Effects of angular velocity on Accelerating Quark-Antiquark pair in $AdS_3$

    CERN Document Server

    Sadeghi, Jafar

    2015-01-01

    In order to study quark and anti-quark interaction, one should consider all effects of the medium in motion of the pair. Because the pair, is not produced at rest in QGP. So the velocity of the pair, has some effects on its interactions that should be taken into account. In this paper we apply some conformal transformations for a rotat- ing string dual to a rotating heavy quark in $AdS_3$ which construct an accelerating string dual to an accelerating quark and anti-quark pair. So, we can have a comparison between when pair has angular velocity or not. Then we can study effects of angular velocity on the accelerating quark and anti-quark which are constructed by performing special con- formal transformations, conformal SO(2,2) transformation and particular $SL(2;R)_L$ and $SL(2;R)_R$ transformation. The accelerating quark and anti-quark show different behavior with increasing in angular velocity. With useful numerical solutions we show that quark and anti-quark can deccelerate to achieve each other or accelera...

  2. Charged vector particle tunneling from a pair of accelerating and rotating and 5D gauged super-gravity black holes

    Energy Technology Data Exchange (ETDEWEB)

    Javed, Wajiha; Ali, Riasat [University of Education, Division of Science and Technology, Lahore (Pakistan); Abbas, G. [The Islamia University of Bahawalpur, Department of Mathematics, Bahawalpur (Pakistan)

    2017-05-15

    The aim of this paper is to study the quantum tunneling process for charged vector particles through the horizons of more generalized black holes by using the Proca equation. For this purpose, we consider a pair of charged accelerating and rotating black holes with Newman-Unti-Tamburino parameter and a black hole in 5D gauged super-gravity theory, respectively. Further, we study the tunneling probability and corresponding Hawking temperature for both black holes by using the WKB approximation. We find that our analysis is independent of the particles species whether or not the background black hole geometries are more generalized. (orig.)

  3. Experimental and numerical examination of eddy (Foucault) currents in rotating micro-coils: Generation of heat and its impact on sample temperature.

    Science.gov (United States)

    Aguiar, Pedro M; Jacquinot, Jacques-François; Sakellariou, Dimitris

    2009-09-01

    The application of nuclear magnetic resonance (NMR) to systems of limited quantity has stimulated the use of micro-coils (diameter Foucault (eddy) currents, which generate heat. We report the first data acquired with a 4mm MACS system and spinning up to 10kHz. The need to spin faster necessitates improved methods to control heating. We propose an approximate solution to calculate the power losses (heat) from the eddy currents for a solenoidal coil, in order to provide insight into the functional dependencies of Foucault currents. Experimental tests of the dependencies reveal conditions which result in reduced sample heating and negligible temperature distributions over the sample volume.

  4. MAXWELL’S EQUTIONS AND YANG-MILLS THEORY IN THE METRIC OF ACCELERATING AND ROTATING REFERENCE SYSTEMS IN GENERAL RELATIVITY

    Directory of Open Access Journals (Sweden)

    Trunev A. P.

    2015-04-01

    Full Text Available Metric describing the accelerated and rotating reference system in general relativity in the case of an arbitrary dependence of acceleration and angular velocity on time has been proposed. It is established that the curvature tensor in such metrics is zero, which corresponds to movement in the flat spaces. It is shown that the motion of test bodies in the metric accelerated and rotating reference system in general relativity is similarly to the classical motion in non-inertial reference frame. Maxwell's equations and Yang-Mills theory are converted to the moving axes in metric describes the acceleration and rotating reference frame in the general relativity in the case of an arbitrary dependence of acceleration and angular velocity of the system from time. The article discusses the known effects associated with acceleration and (or the rotation of the reference frame - the Sagnac effect, the effect of the Stewart-Tolman and other similar effects. The numerical model of wave propagation in non-inertial reference frames in the case when potential depending of one, two and three spatial dimensions has been developed. It has been shown in numerical experiment that the acceleration of the reference system leads to retardation effects, as well as to a violation of the symmetry of the wave front, indicating that there is local change of wave speed

  5. The Nano-X Linear Accelerator: A Compact and Economical Cancer Radiotherapy System Incorporating Patient Rotation.

    Science.gov (United States)

    Eslick, Enid M; Keall, Paul J

    2015-10-01

    Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements.

  6. Head linear and rotational accelerations and craniocervical loads in lateral impact

    NARCIS (Netherlands)

    Yoganandan, N.; Pintar, F.A.; Maiman, D.; Phillippens, M.M.G.M.; Wismans, J.S.H.M.

    2006-01-01

    The objective of the study was to determine lateral impact-induced three-dimensional temporal head center of gravity linear and angular accelerations, and craniocervical forces and moments from post mortem human subject (PMHS) sled tests and compare with the European side impact dummy, ES-II, respon

  7. Acceleration and Rotation in a Pendulum Ride, Measured Using an iPhone 4

    Science.gov (United States)

    Pendrill, Ann-Marie; Rohlen, Johan

    2011-01-01

    Many modern cell phones have built-in sensors that may be used as a resource for physics education. Amusement rides offer examples of many different types of motion, where the acceleration leads to forces experienced throughout the body. A comoving 3D-accelerometer gives an electronic measurement of the varying forces acting on the rider, but a…

  8. Computer simulations predict that chromosome movements and rotations accelerate mitotic spindle assembly without compromising accuracy.

    Science.gov (United States)

    Paul, Raja; Wollman, Roy; Silkworth, William T; Nardi, Isaac K; Cimini, Daniela; Mogilner, Alex

    2009-09-15

    The mitotic spindle self-assembles in prometaphase by a combination of centrosomal pathway, in which dynamically unstable microtubules search in space until chromosomes are captured, and a chromosomal pathway, in which microtubules grow from chromosomes and focus to the spindle poles. Quantitative mechanistic understanding of how spindle assembly can be both fast and accurate is lacking. Specifically, it is unclear how, if at all, chromosome movements and combining the centrosomal and chromosomal pathways affect the assembly speed and accuracy. We used computer simulations and high-resolution microscopy to test plausible pathways of spindle assembly in realistic geometry. Our results suggest that an optimal combination of centrosomal and chromosomal pathways, spatially biased microtubule growth, and chromosome movements and rotations is needed to complete prometaphase in 10-20 min while keeping erroneous merotelic attachments down to a few percent. The simulations also provide kinetic constraints for alternative error correction mechanisms, shed light on the dual role of chromosome arm volume, and compare well with experimental data for bipolar and multipolar HT-29 colorectal cancer cells.

  9. Circular orbits and acceleration of particles by near-extremal dirty rotating black holes: general approach

    CERN Document Server

    Zaslavskii, O B

    2012-01-01

    We study the effect of ultra-high energy particles collisions near the black hole horizon (BSW effect) for two scenarios: when one of particle either (i) moves on a circular orbits or (ii) plunges from it towards the horizon. It is shown that such circular near-horizon orbits can exist for near-extremal black holes only. This includes the innermost stable orbit (ISCO), marginally bound orbit (MBO) and photon one (PhO). We consider generic "dirty" rotating black holes not specifying the metric and show that the energy in the centre of mass frame has the universal scaling dependence on the surface gravity {\\kappa}. Namely, E_{c.m.}\\sim{\\kappa}^{-n} where for the ISCO n=(1/3) in case (i) or n=(1/2) in case (ii). For the MBO and PhCO n=(1/2) in both scenarios that agrees with recent calculations of Harada and Kimura for the Kerr metric. We also generalize the Grib and Pavlov's observations made for the Kerr metric. The magnitude of the BSW effect on the location of collision has a somewhat paradoxical character: ...

  10. Coiled-Coil Design: Updated and Upgraded.

    Science.gov (United States)

    Woolfson, Derek N

    2017-01-01

    α-Helical coiled coils are ubiquitous protein-folding and protein-interaction domains in which two or more α-helical chains come together to form bundles. Through a combination of bioinformatics analysis of many thousands of natural coiled-coil sequences and structures, plus empirical protein engineering and design studies, there is now a deep understanding of the sequence-to-structure relationships for this class of protein architecture. This has led to considerable success in rational design and what might be termed in biro de novo design of simple coiled coils, which include homo- and hetero-meric parallel dimers, trimers and tetramers. In turn, these provide a toolkit for directing the assembly of both natural proteins and more complex designs in protein engineering, materials science and synthetic biology. Moving on, the increased and improved use of computational design is allowing access to coiled-coil structures that are rare or even not observed in nature, for example α-helical barrels, which comprise five or more α-helices and have central channels into which different functions may be ported. This chapter reviews all of these advances, outlining improvements in our knowledge of the fundamentals of coiled-coil folding and assembly, and highlighting new coiled coil-based materials and applications that this new understanding is opening up. Despite considerable progress, however, challenges remain in coiled-coil design, and the next decade promises to be as productive and exciting as the last.

  11. Accelerating flight: Edge with arbitrary acceleration

    CSIR Research Space (South Africa)

    Gledhill, Irvy MA

    2011-11-01

    Full Text Available ? temporal scales ? Euler ? convection ? Reynolds ? translational viscous ? Ekman ? rotational viscous ? Translational acceleration ? related to g ? Rotational accleration ? Rossby ? Coriolis ? Centrifugal ? Gravitational ? CSIR 2009...

  12. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  13. Electromagnetic Gun With Commutated Coils

    Science.gov (United States)

    Elliott, David G.

    1991-01-01

    Proposed electromagnetic gun includes electromagnet coil, turns of which commutated in sequence along barrel. Electrical current fed to two armatures by brushes sliding on bus bars in barrel. Interaction between armature currents and magnetic field from coil produces force accelerating armature, which in turn, pushes on projectile. Commutation scheme chosen so magnetic field approximately coincides and moves with cylindrical region defined by armatures. Scheme has disadvantage of complexity, but in return, enables designer to increase driving magnetic field without increasing armature current. Attainable muzzle velocity increased substantially.

  14. Designing Stable Antiparallel Coiled Coil Dimers

    Institute of Scientific and Technical Information of China (English)

    曾宪纲; 周海梦

    2001-01-01

    The history of antiparallel coiled coil dimer design is briefly reviewed and the main principles governing the successful designs are explained. They include analysis of the inter-subunit electrostatic repulsion for determining partners for dimerization and of the buried polar interaction for determining the relative orientation of the partners. A theory is proposed to explain the lack of antiparallel coiled coil homodimers in nature.

  15. Fast-light Enhanced Brillouin Laser Based Active Fiber Optics Sensor for Simultaneous Measurement of Rotation and Acceleration

    CERN Document Server

    Zhou, Minchuan; Fouda, Mohamed; Condon, Nicholas; Scheuer, Jacob; Shahriar, Selim M

    2016-01-01

    We have developed a conceptual design for an Active Fast Light Fiber Optic Sensor (AFLIFOS) that can perform simultaneously or separately as a gyroscope (differential mode effect) and a sensor for acceleration, strain, and other common mode effects. Two Brillouin lasers in opposite directions and separated in frequency by several free spectral ranges are used for this sensor. By coupling two auxiliary resonators to the primary fiber resonator, we produce superluminal effects for two laser modes. We develop a detailed theoretical model for optimizing the design of the AFLIFOS, and show that the enhancement factor of the sensitivity is $\\sim{187}$ and $\\sim{-187}$, respectively for the two Brillouin lasers under the optimized condition, when the effective change in perimeter of the primary fiber resonator is 0.1nm, corresponding to a rotation rate of 0.4 deg/sec for a ring resonator with radius 1m. It may be possible to get much higher enhancement by adjusting the parameters such as the perimeters and the coupl...

  16. Neck Flexion Induces Larger Deformation of the Brain Than Extension at a Rotational Acceleration, Closed Head Trauma

    Directory of Open Access Journals (Sweden)

    Hans-Arne Hansson

    2014-01-01

    Full Text Available A closed head trauma induces incompletely characterized temporary movement and deformation of the brain, contributing to the primary traumatic brain injury. We used the pressure patterns recorded with light-operated miniature sensors in anaesthetized adult rabbits exposed to a sagittal plane rotational acceleration of the head, lasting 1 ms, as a measure of brain deformation. Two exposure levels were used and scaled to correspond to force levels reported to cause mild and moderate diffuse injury in an adult man, respectively. Flexion induced transient, strong, extended, and predominantly negative pressures while extension generated a short positive pressure peak followed by a minor negative peak. Low level flexion caused as strong, extended negative pressures as did high level extension. Time differences were demonstrated between the deformation of the cerebrum, brainstem, and cerebellum. Available X-ray and MRI techniques do not have as high time resolution as pressure recordings in demonstrating complex, sequential compression and stretching of the brain during a trauma. The exposure to flexion caused more protracted and extensive deformation of the brain than extension, in agreement with a published histopathological report. The severity and extent of the brain deformation generated at a head trauma thus related to the direction at equal force.

  17. Coil Welding Aid

    Science.gov (United States)

    Wiesenbach, W. T.; Clark, M. C.

    1983-01-01

    Positioner holds coil inside cylinder during tack welding. Welding aid spaces turns of coil inside cylinder and applies contact pressure while coil is tack-welded to cylinder. Device facilitates fabrication of heat exchangers and other structures by eliminating hand-positioning and clamping of individual coil turns.

  18. Starfire poloidal coil systems

    Energy Technology Data Exchange (ETDEWEB)

    Evans, K. Jr.; Kim, S.H.; Turner, L.R.; Wang, S.T.

    1980-01-01

    The poloidal coils for STARFIRE consists of three systems: (1) equilibrium field (EF) coils; (2) ohmic heating (OH) coils; and (3) correction field (CF) coils. The EF coils are superconducting and lie outside the toroidal field (TF) coils. These coils provide the bulk of the equilibrium field necessary to keep the plasma positioned in the vacuum chamber with the desired cross sectional shape and pressure and current distributions. Having these coils outside of the TF coils requires that they have a larger stored energy and larger currents but eases the assembly, maintenance, and reliability of the coils. The STARFIRE OH system is relatively small compared to tokamaks in which the current is entirely ohmically driven. It is designed to provide sufficient flux in the early startup to raise the plasma current to the point (1 to 2 MA) where the rf current drive can take over.

  19. Modular Coils and Plasma Configurations for Quasi-axisymmetric Stellarators

    Energy Technology Data Exchange (ETDEWEB)

    L.P. Ku and A.H. Boozer

    2010-09-10

    Characteristics of modular coils for quasi-axisymmetric stellarators that are related to the plasma aspect ratio, number of field periods and rotational transform have been examined systematically. It is observed that, for a given plasma aspect ratio, the coil complexity tends to increase with the increased number of field periods. For a given number of field periods, the toroidal excursion of coil winding is reduced as the plasma aspect ratio is increased. It is also clear that the larger the coil-plasma separation is, the more complex the coils become. It is further demonstrated that it is possible to use other types of coils to complement modular coils to improve both the physics and the modular coil characteristics.

  20. Natural Convection Heat and Mass Transfer Flow with Hall Current, Rotation, Radiation and Heat Absorption Past an Accelerated Moving Vertical Plate with Ramped Temperature

    Directory of Open Access Journals (Sweden)

    Gauri Shanker Seth

    2015-01-01

    Full Text Available An investigation of unsteady hydromagnetic natural convection heat and mass trans fer flow with Hall current of a viscous, incompressible, electrically conducting, heat absorbing and optically thin radiating fluid past an accelerated moving vertical plate through fluid saturated porous medium in a rotating environment is carried out when temperature of the plate has a temporarily ramped profile. The exact solutions of momentum, energy and concentration equations are obtained in closed form by Laplace transform technique. The expressions of skin friction, Nusselt number and Sherwood number are also derived. For both ramped temperature and isothermal plates, Hall current tends to accelerate primary and secondary fluid velocities whereas heat absorption and radiation have reverse effect on it. Rotation tends to retard primary fluid velocity whereas it has a reverse effect on secondary fluid velocity. Heat absorption and radiation have tendency to enhance rate of heat transfer at the plate.

  1. Comparison of fixation properties between coil-type and screw-type anchors for rotator cuff repair: A virtual pullout testing using 3-dimensional finite element method.

    Science.gov (United States)

    Sano, Hirotaka; Tokunaga, Masako; Noguchi, Moriyuki; Inawashiro, Takashi; Irie, Taichi; Abe, Hiroo; Abrassart, Sophie; Itoi, Eiji

    2016-07-01

    Pullout of inserted anchor constitutes one of the pathomechanisms of re-tearing after rotator cuff repair. The purpose of the present study was to investigate the fixation properties of suture anchors using 3-dimensional finite element method. The computer models of three types of anchors (TwinFix Ti, HEALICOIL PK and HEALICOIL RG) were inserted into the isotropic cube model that simulated cancellous bone. In the virtual pullout testing, a tensile load (500 N) along the long axis of the inserted anchor was applied to the site of suture thread attachment to simulate a traction force. The distribution of von Mises equivalent stress, the failure patterns of elements inside the cube and the anchor displacement were compared among the three anchors. In TwinFix Ti, the highest stress concentration was seen around the anchor threads close to the surface of the cube, which caused element failure at this site. On the other hand, both HEALICOIL PK and HEALICOIL RG demonstrated a high stress concentration as well as element failure around the anchor tip. Comparing the anchor displacement, HEALICOIL RG showed the smallest displacement among the three anchors. The tensile loads that required a 0.1-mm displacement for TwinFix Ti, HEALICOIL PK and HEALICOIL RG were 400 N, 370 N, and greater than 500 N, respectively. The bony structures close to the footprint surface may be damaged during surgery due to preparation for the bony bed as well as the insertion of anchors. Thus, we assumed that HEALICOIL RG represented the best initial fixation properties among the three anchors tested. Virtual pullout testing using 3-dimensional finite element method could reveal the detailed biomechanical characteristics of each suture anchor, which would be important for shoulder surgeons to improve the clinical outcomes of rotator cuff repair. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  2. Needleless Electrospinning of Uniform Nanofibers Using Spiral Coil Spinnerets

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2012-01-01

    Full Text Available Polyvinyl alcohol nanofibers were prepared by a needleless electrospinning technique using a rotating spiral wire coil as spinneret. The influences of coil dimension (e.g., coil length, coil diameter, spiral distance, and wire diameter and operating parameters (e.g., applied voltage and spinning distance on electrospinning process, nanofiber diameter, and fiber productivity were examined. It was found that the coil dimension had a considerable influence on the nanofiber production rate, but minor effect on the fiber diameter. The fiber production rate increased with the increased coil length or coil diameter, or the reduced spiral distance or wire diameter. Higher applied voltage or shorter collecting distance also improved the fiber production rate but had little influence on the fiber diameter. Compared with the conventional needle electrospinning, the coil electrospinning produced finer fibers with a narrower diameter distribution. A finite element method was used to analyze the electric field on the coil surface and in electrospinning zone. It was revealed that the high electric field intensity was concentrated on the coil surface, and the intensity was highly dependent on the coil dimension, which can be used to explain the electrospinning performances of coils. In addition, PAN nanofibers were prepared using the same needleless electrospinning technique to verify the improvement in productivity.

  3. THE INVESTIGATION OF THE ACCELERATION PROCESS OF A MACHINE AND TRACTOR UNIT ON THE BASIS OF CLASS 1,4 TRACTOR WITH A VARIABLE ROTATING MASS OF THE ENGINE

    Directory of Open Access Journals (Sweden)

    Kravchenko V. A.

    2015-11-01

    Full Text Available The aim of the work is theoretical and experimental confirmation of the possibility of improvement in tractor unit acceleration due to the variable inertia moment of the rotating masses of the engine. The use of high-speed tractors in agricultural production meets a number of difficulties associated with unsteady processes during acceleration of the tractor units. The emerging significant inertial loads during acceleration result in the loss of engine power because of what the machine and tractor unit is operating at reduced productivity and efficiency. An analysis of published works shows that the tractor unit acceleration is strongly influenced by the rotating mass of the engine. A device based on the application of additional rotating masses in a free flywheel connected or disconnected automatically to the main engine flywheel at appropriate stages is offered. As a result, the tension during acceleration is reduced. The results of experimental studies on the effect of the additional rotating masses on the engine acceleration characteristics of the machine and tractor units on the basis of Class 1.4 tractor are given. It is proved that the use of the tractor additional rotating mass connected or disconnected to the respective modes of movement of a machine and tractor unit to the flywheel of the engine, improves acceleration performance

  4. Dual coil ignition system

    Energy Technology Data Exchange (ETDEWEB)

    Huberts, Garlan J.; Qu, Qiuping; Czekala, Michael Damian

    2017-03-28

    A dual coil ignition system is provided. The dual coil ignition system includes a first inductive ignition coil including a first primary winding and a first secondary winding, and a second inductive ignition coil including a second primary winding and a second secondary winding, the second secondary winding connected in series to the first secondary winding. The dual coil ignition system further includes a diode network including a first diode and a second diode connected between the first secondary winding and the second secondary winding.

  5. Acceleration of Amide Bond Rotation by Encapsulation in the Hydrophobic Interior of a Water-Soluble Supramolecular Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Pluth, Michael D.; Bergman, Robert G.; Raymond, Kenneth N.

    2008-04-08

    The hydrophobic interior cavity of a self-assembled supramolecular assembly exploits the hydrophobic effect for the encapsulation of tertiary amides. Variable temperature 1H NMR experiments reveal that the free energy barrier for rotation around the C-N amide bond is lowered by up to 3.6 kcal/mol upon encapsulation. The hydrophobic cavity of the assembly is able to stabilize the less polar transition state of the amide rotation process. Carbon-13 labeling studies showed that the {sup 13}C NMR carbonyl resonance increases with temperature for the encapsulated amides which suggests that the assembly is able to favor a twisted for of the amide.

  6. Coil system for plasmoid thruster

    Science.gov (United States)

    Eskridge, Richard H. (Inventor); Lee, Michael H. (Inventor); Martin, Adam K. (Inventor); Fimognari, Peter J. (Inventor)

    2010-01-01

    A coil system for a plasmoid thruster includes a bias coil, a drive coil and field coils. The bias and drive coils are interleaved with one another as they are helically wound about a conical region. A first field coil defines a first passage at one end of the conical region, and is connected in series with the bias coil. A second field coil defines a second passage at an opposing end of the conical region, and is connected in series with the bias coil.

  7. Electromagnetic Design of Superconducting Dipoles Based on Sector Coils

    CERN Document Server

    Todesco, Ezio

    2007-01-01

    We study the coil lay-outs of superconducting dipoles for particle accelerators based on the sector geometry. We show that a simple model based on a sector coil with a wedge allows us to derive an equation giving the short sample field as a function of the aperture, coil width, cable properties and superconducting material. The equation agrees well with the actual results of several dipole coils that have been built in the last 30 years. The improvements due to the grading technique and the iron yoke are also studied. The proposed equation can be used as a benchmark to judge the efficiency of the coil design, and to carry out a global optimization of an accelerator lay-out.

  8. Optimal Bitter Coil Solenoid

    CERN Document Server

    Kobelev, V

    2016-01-01

    Bitter coil is an electromagnet used for the generation of exceptionally strong magnetic fields. The upper bound of magnet flux density is restricted by several factors. One principal restriction is the high stresses due to Lorentz forces in the coil. The Lorentz forces generate the distributed body force, which acts as the pressure of magnetic field. The common radial thickness profile of the Bitter coil is constant. In this paper the possibility of optimization by means of non-constant radial thickness profile of the Bitter coil is studied. The close form expression for optimal thickness profile is obtained. Both designs are compared and the considerable improvement of magnetic flux density is demonstrated. Moreover, the optimal design improves the shape of cooling channels. Namely, the highest cross-section of cooling channel is at the most thermally loaded inner surface of the coil.

  9. Comparison of an Electromagnetic Energy Harvester Performance using Wound Coil Wire and PCB Coil

    Science.gov (United States)

    Resali, MSM; Salleh, H.

    2016-03-01

    This paper presents the performance of two types of electromagnetic energy harvester, one using manually wound coil wire (EH-EC) and the other one using printed circuit board (PCB) coil (EH-EP). The objective of the study is to measure the corresponding output voltage and power by varying the number of coils and the position of the magnet. The experiment was conducted at a fix 50 Hz of frequency and at 0.25g of acceleration. The EH-EP was found to be more effective than the 350 turns of the wound coil wire, with maximum power of 26 μW. Overall, the performance of the EH-EC showed better result with maximum power of 125 μW for 1050 turns when compared to the EH-EP.

  10. Free convective heat transfer with hall effects, heat absorption and chemical reaction over an accelerated moving plate in a rotating system

    Science.gov (United States)

    Hussain, S. M.; Jain, J.; Seth, G. S.; Rashidi, M. M.

    2017-01-01

    The unsteady MHD free convective heat and mass transfer flow of an electrically conducting, viscous and incompressible fluid over an accelerated moving vertical plate in the presence of heat absorption and chemical reaction with ramped temperature and ramped surface concentration through a porous medium in a rotating system is studied, taking Hall effects into account. The governing equations are solved analytically with the help of Laplace transform technique. The unified closed-form expressions are obtained for fluid velocity, fluid temperature, species concentration, skin friction, Nusselt number and Sherwood numbers. The effects of various parameters on fluid velocity, fluid temperature and species concentration are discussed by graphs whereas numerical values of skin friction, Nusselt and Sherwood numbers are presented in tabular form for different values of pertinent flow parameters. The numerical results are also compared with free convective flow near ramped temperature plate with ramped surface concentration with the corresponding flow near isothermal plate with uniform surface concentration.

  11. Commercial applications for COIL

    Science.gov (United States)

    Solomon, Wayne C.; Carroll, David L.; King, D. M.; Fockler, L. A.; Stromberg, D. S.; Sexauer, M.; Milmoe, A.; Sentman, Lee H.

    2000-01-01

    The chemical oxygen-iodine laser (COIL) is a high power, fiber deliverable tool, which can be used for a number of different industrial applications. COIL is of particular interest because of its short fiber deliverable wavelength, high scaleable continuous wave power, and excellent material interaction properties. In past research the University of Illinois at Urbana-Champaign identified and decommissioning and decontamination (DD) of nuclear facilities as a primary focus for COIL technology. DD will be a major challenge in the coming decades. The use of a robotically driven fiber delivered cutting/ablation tool in contaminated areas promises to lower risks to workers for the DD mission. Further, the high cutting speed of COIL will significantly reduce the time required to cut contaminated equipment, reducing costs. The high power of COIL will permit the dismantling of thick stacks of piping and equipment as well as reactor vessels. COIL is very promising for the removal of material from contaminated surfaces, perhaps to depths thicker than an inch. Laser cutting and ablation minimizes dust and fumes, which reduces the required number of high efficiency particulate accumulator filters, thus reducing costly waste disposal. Other potential industrial applications for COIL are shipbuilding, automotive manufacturing, heavy machinery manufacturing, tasks requiring underwater cutting or welding, and there appear to be very promising applications for high powers lasers in the oil industry.

  12. Thermographic Method Based Accelerated Fatigue Limit Calculation for Steel X5CrNi18-10 Subjected to Rotating Bending

    Directory of Open Access Journals (Sweden)

    Lipski Adam

    2015-12-01

    Full Text Available The article presents an accelerated method for fatigue limit calculation which makes use of constant temperature increase rate observed in the middle time interval of specimen fatigue loading. The examination was performed on specimens prepared from drawn rods made of corrosion resistant austenitic steel X5CrNi18-10 (1.4301 subjected to rotating bending. For comparison purposes, the fatigue limit was also calculated with the aid of the Staircase method, using 30 specimens and assuming the base number of cycles equal to 10·106. Three specimens were used for accelerated examination during which their temperature was measured with the aid of the thermographic camera CEDIP Silver 420M (FLIR SC 5200. The applied loads were gradually increased until specimen damage took place. Based on the analysis of temperature changes during specimen loading, the average rate of temperature increase at successive loading stages was assessed. The obtained results were then approximated using the 2-nd order curve and its minimal value was assumed as corresponding to the fatigue limit. The performed statistic test has revealed that the fatigue limit calculated in the above way does not differ substantially from that determined using the Staircase method.

  13. A periodic table of coiled-coil protein structures.

    Science.gov (United States)

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  14. Effect of Metal Proximity on a Pulsed Copper Coil

    Science.gov (United States)

    Johnson, H. K.; Schaffner, D. A.; Brown, M. R.; Kaur, M.; Fiedler-Kawaguchi, C.

    2016-10-01

    Generating and accelerating plasma in a stainless steel chamber affects the magnetic fields inside. These effects will decrease the field due to a pulsed coil (which will later be used to accelerate plasma) inside the chamber. This work is being done in conjunction with the Swarthmore Spheromak Experiment. Both facilities are collaborating in an attempt to accelerate and compress plasma as part of ARPA-E's Accelerating Low-Cost Plasma Heating and Assembly (ALPHA) program. Measurements of the impact of the chamber on the coil's magnetic fields were made using a B-dot probe inside the coil, which was placed at incremental distances from a metal plate. As the coil is moved from the plate, the plate's interference with the field was seen to exponentially decay. This process was repeated for stainless steel, aluminum, and copper, and a range of voltages (500-800V). At least seventy percent of the original signal was recovered within two inches. Pulsing the coil inside the stainless steel chamber resulted in signals about one third the strength of those measured outside of the chamber. The results of this experiment will be used to guide development of the stainless steel pulse-coil system for the Swarthmore ALPHA project. Work supported by ARPA-E ALPHA program.

  15. Applying DTI white matter orientations to finite element head models to examine diffuse TBI under high rotational accelerations.

    LENUS (Irish Health Repository)

    Colgan, Niall C

    2010-12-01

    The in-vivo mechanical response of neural tissue during impact loading of the head is simulated using geometrically accurate finite element (FE) head models. However, current FE models do not account for the anisotropic elastic material behaviour of brain tissue. In soft biological tissue, there is a correlation between internal microscopic structure and macroscopic mechanical properties. Therefore, constitutive equations are important for the numerical analysis of the soft biological tissues. By exploiting diffusion tensor techniques the anisotropic orientation of neural tissue is incorporated into a non-linear viscoelastic material model for brain tissue and implemented in an explicit FE analysis. The viscoelastic material parameters are derived from published data and the viscoelastic model is used to describe the mechanical response of brain tissue. The model is formulated in terms of a large strain viscoelastic framework and considers non-linear viscous deformations in combination with non-linear elastic behaviour. The constitutive model was applied in the University College Dublin brain trauma model (UCDBTM) (i.e. three-dimensional finite element head model) to predict the mechanical response of the intra-cranial contents due to rotational injury.

  16. LHCb magnet coils arrive

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Each of the two coils for the LHCb magnet comprises 15 individual monolayer 'pancakes' of identical trapezoidal racetrack shape, and is bent at 45 degrees on the two transverse sides. Each pancake consists of eight turns of conductor, wound from a single length (approx. 290 m) of extruded aluminium. The coils have arrived at CERN; one of them is seen here being unloaded above the LHCb experimental cavern.

  17. Coiling of yield stress fluids

    NARCIS (Netherlands)

    Y. Rahmani; M. Habibi; A. Javadi; D. Bonn

    2011-01-01

    We present an experimental investigation of the coiling of a filament of a yield stress fluid falling on a solid surface. We use two kinds of yield stress fluids, shaving foam and hair gel, and show that the coiling of the foam is similar to the coiling of an elastic rope. Two regimes of coiling (el

  18. Linear Rogowski coil

    Science.gov (United States)

    Nassisi, V.; Delle Side, D.

    2017-02-01

    Nowadays, the employment and development of fast current pulses require sophisticated systems to perform measurements. Rogowski coils are used to diagnose cylindrical shaped beams; therefore, they are designed and built with a toroidal structure. Recently, to perform experiments of radiofrequency biophysical stresses, flat transmission lines have been developed. Therefore, in this work we developed a linear Rogowski coil to detect current pulses inside flat conductors. The system is first approached by means of transmission line theory. We found that, if the pulse width to be diagnosed is comparable with the propagation time of the signal in the detector, it is necessary to impose a uniform current as input pulse, or to use short coils. We further analysed the effect of the resistance of the coil and the influence of its magnetic properties. As a result, the device we developed is able to record pulses lasting for some hundreds of nanoseconds, depending on the inductance, load impedance, and resistance of the coil. Furthermore, its response is characterized by a sub-nanosecond rise time (˜100 ps). The attenuation coefficient depends mainly on the turn number of the coil, while the fidelity of the response depends both on the magnetic core characteristics and on the current distribution along the plane conductors.

  19. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Energy Technology Data Exchange (ETDEWEB)

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Szegedi, Martin; Rassiah-Szegedi, Prema [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Shukla, Himanshu, E-mail: bill.salter@hci.utah.edu [Oncology Care Systems Group, Siemens Medical Solutions (USA), 4040 Nelson Avenue, Concord, CA (United States)

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min{sup -1}) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  20. Quench and recovery characteristics of a racetrack double pancake coil wound with YBCO-coated conductor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H M; Kwon, Y K; Lee, J D [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of); Song, J B; Lee, H G [Department of Materials Science and Engineering, Korea University, Seoul (Korea, Republic of)], E-mail: haigunlee@korea.ac.kr

    2009-02-15

    The reliability of high temperature superconducting (HTS) racetrack coils is one of the most important factors for the development of large-scale rotating machines. However, it is necessary to investigate the stability and normal zone propagation characteristics of racetrack coils for large-scale applications such as ship propulsion motors and power generators. In this study, the quench/recovery characteristics of a racetrack-type, double pancake (DP) coil, which could be applied to HTS rotating machines, were investigated using the voltage and temperature profiles in a cryogenic conduction cooling system. The minimum quench heating flux and quench propagation velocity of the racetrack DP coil are also discussed.

  1. Quench and recovery characteristics of a racetrack double pancake coil wound with YBCO-coated conductor

    Science.gov (United States)

    Kim, H. M.; Kwon, Y. K.; Lee, J. D.; Song, J. B.; Lee, H. G.

    2009-02-01

    The reliability of high temperature superconducting (HTS) racetrack coils is one of the most important factors for the development of large-scale rotating machines. However, it is necessary to investigate the stability and normal zone propagation characteristics of racetrack coils for large-scale applications such as ship propulsion motors and power generators. In this study, the quench/recovery characteristics of a racetrack-type, double pancake (DP) coil, which could be applied to HTS rotating machines, were investigated using the voltage and temperature profiles in a cryogenic conduction cooling system. The minimum quench heating flux and quench propagation velocity of the racetrack DP coil are also discussed.

  2. Development of Computational Models for Coiling Process with the Belt Wrapper

    Science.gov (United States)

    Park, Yonghui; Park, Hyunchul

    2016-10-01

    This study introduces coiling mechanism with the belt wrapper to understand a force equilibrium for successful coiling. By establishing a finite element (FE) model, strips were coiled 2 to 3 rotations by the belt wrapper on the sleeve without coiling tension T, then T was applied to the opposite side of the strips near the pinch roller, and the belt wrapper was removed from the strip coil at the same time. Additionally, analytical model corresponding to FE model was defined by thick and thin cylinder theorems to quantize coiling mechanisms. Especially elasticity of the belt wrapper E [N/m2], coiling tension T [N/m2], and friction coefficient μ were checked on how these variables affect each other, were converted into pressure P [N/m2], and P were used to calculate when the strip coil come untied. For instance, the strip coil came untied when E was lower than 1 × 109 N/m2 corresponding to ( {{{{Pressure}} {{on}} {{outmost}} {{of the belt wrapper}} P_{{o,belt}} }/{{{Pressure} {{on}} {{innermost}} {{of the sleeve}} P_{{i,sleeve}} }} = 0.877} ) . Lastly, radial stress on the outmost of the sleeve σ r,o,sleeve [N/m2] according to E were compared to the previous coiling method with the grooved joint to see how these methods are different. Based on these results, this paper suggests coiling criteria to avoid coiling failure of slip of the strip coil.

  3. Coiled coils and SAH domains in cytoskeletal molecular motors.

    Science.gov (United States)

    Peckham, Michelle

    2011-10-01

    Cytoskeletal motors include myosins, kinesins and dyneins. Myosins move along tracks of actin filaments, whereas kinesins and dyneins move along microtubules. Many of these motors are involved in trafficking cargo in cells. However, myosins are mostly monomeric, whereas kinesins are mostly dimeric, owing to the presence of a coiled coil. Some myosins (myosins 6, 7 and 10) contain an SAH (single α-helical) domain, which was originally thought to be a coiled coil. These myosins are now known to be monomers, not dimers. The differences between SAH domains and coiled coils are described and the potential roles of SAH domains in molecular motors are discussed.

  4. First assembly phase for the ATLAS toroid coils

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The ATLAS barrel toroid system consists of eight coils, each of axial length 25.3 m, assembled radially and symmetrically around the beam axis. The coils are of a flat racetrack type with two double-pancake windings made of 20.5 kA aluminium-stabilized niobium-titanium superconductor. In the first phase of assembly, the two 'pancakes' are packed into their vacuum vessel. This is done using bladders filled with resin and glass microbeads under pressure. The resin is heated and, once cooled, holds the pancakes in place. The operation has to be performed on both sides of the coil, which necessitated a special technique to turn the coils over and then transport them to the heating table. Photos 01, 02, 03: Use of the overhead travelling crane to hoist the coil up and then tilt it over, the coil frame's metal feet being used as rotational pivots, supporting half the coil's weight. Once it has been turned over, the coil, now with only half the frame, is transported to the heating table using a special lifting gant...

  5. Second Barrel Toroid Coil Installed in ATLAS Cavern

    CERN Multimedia

    Tappern, G.

    The second barrel toroid coil was lowered into the ATLAS Cavern on Friday, 26 November. The operation takes approximately five hours of precision crane and winch operations. Before lowering, several checks are made to ensure that no loose items have been left on the coil which would fall during the lowering down the shaft. This is a very difficult, but very important check, with the first coil in position, and partly below the shaft. After changing the winch tooling on Wednesday December 1st, the coil was lifted, rotated and placed into the feet. The girders which support the coil and the Z direction stops had all been pre-set before putting the coil in the feet. The angle is controlled by an inclinometer. When the final adjustments of position have been made, which will locate the coils at the plus/minus two mm level, the connection beams (voussoirs and struts) will be put in place; this requires a complex shimming procedure. This will lock together the two coils into the feet and forms the foundation for th...

  6. Design of Electromagnetic Moving-coil type Voice Coil Motor for Scanning mirror of Barcode reader

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Bu Hyun; Lee, Jeong Woo; Shim, Hyun Ho; Park, Sang Goo [Hanbat National Univ., Daejeon (Korea, Republic of); Lee, Seung Yop [Sogang Univ., Seoul (Korea, Republic of)

    2016-01-15

    A voice coil actuator with moving coil type for scanning mirror system of barcode reader has been developed. The actuator has a simple structure including a magnet, a coil and a pin. The performance of the actuator is analyzed by a linearized theoretical model. And the dynamic performance of the proposed actuator is predicted through motor constant and restoring constant obtained by finite element simulations. The theoretical model was verified by the prototype which has 64 Hz resonance frequency and 60 deg reflecting angle. We also discovered that that 3 V input can make the actuator rotate over 61.8 deg reflecting angle at 50 Hz resonance frequency. The proposed actuator can simplify its driving configuration because of its implementation of open-loop control.

  7. TESLA Coil Research

    Science.gov (United States)

    1992-05-01

    Sloan’s work was actually predated by the earlier work of Nikola Tesla . Sloan mistakenly identified " Tesla Coils" as lumped tuned resonators. The...Lefvw WsnJ L REPORT o]i 3. REPRT TYPE AND OATES COVEIRD May 1992 Special/Aug 1992 - May 1992 Z TITLE AND 5U§nUT S. FUNDING NUMIHRS Tesla Coil Research...STATEMENT 1211. ’ISTRIUUTION COOD Approved for public release; dis~ribution is unlimited 13. ABSTRACT (Masrmum 200 worw) High repetition rate Tesla

  8. Meiosis specific coiled-coil proteins in Shizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Okuzaki Daisuke

    2007-05-01

    Full Text Available Abstract Many meiosis-specific proteins in Schizosaccharomyces pombe contain coiled-coil motifs which play essential roles for meiotic progression. For example, the coiled-coil motifs present in Meu13 and Mcp7 are required for their function as a putative recombinase cofactor complex during meiotic recombination. Mcp6/Hrs1 and Mcp5/Num1 control horsetail chromosome movement by astral microtubule organization and anchoring dynein respectively. Dhc1 and Ssm4 are also required for horsetail chromosome movement. It is clear from these examples that the coiled-coil motif in these proteins plays an important role during the progression of cells through meiosis. However, there are still many unanswered questions on how these proteins operate. In this paper, we briefly review recent studies on the meiotic coiled-coil proteins in Sz. pombe.

  9. Planar, monolithically integrated coil

    NARCIS (Netherlands)

    Roozeboom, F.; Reefman, D.; Klootwijk, J.H.; Tiemeijer, L.F.; Ruigrok, J.

    2013-01-01

    The present invention provides a means to integrate planar coils on silicon, while providing a high inductance. This high inductance is achieved through a special back- and front sided shielding of a material. In many applications, high-value inductors are a necessity. In particular, this holds for

  10. An orientable search coil

    Science.gov (United States)

    Holt, P. J.; Poblocki, M.

    2017-01-01

    We provide a design for a low cost orientable search coil that can be used to investigate the variation of magnetic flux with angle. This experiment is one of the required practical activities in the current A level physics specification for the AQA examination board in the UK. We demonstrate its performance and suggest other suitable investigations that can be undertaken.

  11. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, D.; Gota, H.; Hayashi, R.; Kiyashko, V.; Morehouse, M.; Primavera, S. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Bolte, N. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Marsili, P. [Department of Physics, University of Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Roche, T. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Wessel, F. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2010-10-15

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  12. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC.

    Science.gov (United States)

    Gupta, D; Bolte, N; Gota, H; Hayashi, R; Kiyashko, V; Marsili, P; Morehouse, M; Primavera, S; Roche, T; Wessel, F

    2010-10-01

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  13. Balance between Coiled-Coil Stability and Dynamics Regulates Activity of BvgS Sensor Kinase in Bordetella

    Directory of Open Access Journals (Sweden)

    E. Lesne

    2016-03-01

    Full Text Available The two-component system BvgAS controls the expression of the virulence regulon of Bordetella pertussis. BvgS is a prototype of bacterial sensor kinases with extracytoplasmic Venus flytrap perception domains. Following its transmembrane segment, BvgS harbors a cytoplasmic Per-Arnt-Sim (PAS domain and then a predicted 2-helix coiled coil that precede the dimerization-histidine-phosphotransfer domain of the kinase. BvgS homologs have a similar domain organization, or they harbor only a predicted coiled coil between the transmembrane and the dimerization-histidine-phosphotransfer domains. Here, we show that the 2-helix coiled coil of BvgS regulates the enzymatic activity in a mechanical manner. Its marginally stable hydrophobic interface enables a switch between a state of great rotational dynamics in the kinase mode and a more rigid conformation in the phosphatase mode in response to signal perception by the periplasmic domains. We further show that the activity of BvgS is controlled in the same manner if its PAS domain is replaced with the natural α-helical sequences of PAS-less homologs. Clamshell motions of the Venus flytrap domains trigger the shift of the coiled coil’s dynamics. Thus, we have uncovered a general mechanism of regulation for the BvgS family of Venus flytrap-containing two-component sensor kinases.

  14. Minimax Current Density Coil Design

    CERN Document Server

    Poole, Michael; Lopez, Hector Sanchez; Ng, Michael; Crozier, Stuart; 10.1088/0022-3727/43/9/095001

    2010-01-01

    'Coil design' is an inverse problem in which arrangements of wire are designed to generate a prescribed magnetic field when energized with electric current. The design of gradient and shim coils for magnetic resonance imaging (MRI) are important examples of coil design. The magnetic fields that these coils generate are usually required to be both strong and accurate. Other electromagnetic properties of the coils, such as inductance, may be considered in the design process, which becomes an optimization problem. The maximum current density is additionally optimized in this work and the resultant coils are investigated for performance and practicality. Coils with minimax current density were found to exhibit maximally spread wires and may help disperse localized regions of Joule heating. They also produce the highest possible magnetic field strength per unit current for any given surface and wire size. Three different flavours of boundary element method that employ different basis functions (triangular elements...

  15. Flux Redux: The Spinning Coil Comes around Again

    Science.gov (United States)

    Lund, Daniel; Dietz, Eric; Zou, Xueli; Ard, Christopher; Lee, Jaydie; Kaneshiro, Chris; Blanton, Robert; Sun, Steven

    2017-01-01

    An essential laboratory exercise for our lower-division electromagnetism course involves the measurement of Earth's local magnetic field from the emf induced in a rotating coil of wire. Although many methods exist for the measurement of Earth's field, this one gives our students some practical experience with Faraday's law. The apparatus we had…

  16. Flux Redux: The Spinning Coil Comes around Again

    Science.gov (United States)

    Lund, Daniel; Dietz, Eric; Zou, Xueli; Ard, Christopher; Lee, Jaydie; Kaneshiro, Chris; Blanton, Robert; Sun, Steven

    2017-01-01

    An essential laboratory exercise for our lower-division electromagnetism course involves the measurement of Earth's local magnetic field from the emf induced in a rotating coil of wire. Although many methods exist for the measurement of Earth's field, this one gives our students some practical experience with Faraday's law. The apparatus we had…

  17. Introduction to COIL

    OpenAIRE

    Kane, David

    2008-01-01

    By reciprocal arrangement between WIT and the National College of Ireland, you are now able to access their collection directly - more than 100,000 items. This form of direct consortial borrowing has never been tried before in Ireland. Before you borrow your first book, you will have to set up a COIL account, which is straightforward. The items which you reserve online will be posted to us, for you to collect, at the front desk in the Luke Wadding library, afterwards. The Initiat...

  18. Triple Halo Coil: Development and Comparison with Other TMS Coils

    Science.gov (United States)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  19. Fabrication and Analysis of 150 mm Aperture Nb3Sn LARP MQXF Coils

    CERN Document Server

    Holik, E F; Anerella, M; Bossert, R; Cavanna, E; Cheng, D; Dietderich, D R; Ferracin, P; Ghosh, A K; Izquierdo Bermudez, S; Krave, S; Nobrega, A; Perez, J C; Pong, I; Rochepault; Sabbi, G L; Schmalzle, J; Yu, M

    2016-01-01

    The US LHC Accelerator Research Program (LARP) and CERN are combining efforts for the HiLumi-LHC upgrade to design and fabricate 150 mm aperture, interaction region quadrupoles with a nominal gradient of 130 T/m using Nb3Sn. To successfully produce the necessary long MQXF triplets, the HiLumi-LHC collaboration is systematically reducing risk and design modification by heavily relying upon the experience gained from the successful 120 mm aperture LARP HQ program. First generation MQXF short (MQXFS) coils were predominately a scaling up of the HQ quadrupole design allowing comparable cable expansion during Nb3Sn formation heat treatment and increased insulation fraction for electrical robustness. A total of 13 first generation MQXFS coils were fabricated between LARP and CERN. Systematic differences in coil size, coil alignment symmetry, and coil length contraction during heat treatment are observed and likely due to slight variances in tooling and insulation/cable systems. Analysis of coil cross sections indic...

  20. RWM Feedback Stabilization with the New Internal Coil (I-Coil)

    Science.gov (United States)

    Okabayashi, M.; Chance, M. S.; Bialek, J.; Garofalo, A. M.; Navratil, G. A.; Reimerdes, H.; Chu, M. S.; Jackson, G. L.; Jensen, T. H.; La Haye, R. J.; Scoville, J. T.; Strait, E. J.; Jayakumar, R. J.; Edgell, D. H.

    2003-10-01

    RWM stabilization by rotational viscosity has been observed as a quite robust approach for achieving the stable n=1 kink plasma beta up to ideal wall limit. For less rotation configurations, such as expected in burning plasma, it is highly desirable to establish the same level of robust RWM stabilizing system. VALEN code predicts that newly installed I-coil with upgraded digital control system can provide RWM stabilization up to the ideal wall beta limit using direct feedback even without plasma rotation. A major advantage of new system is the adjustability of poloidal m-component to the plasma eigen mode. To demonstrate the effectiveness of direct feedback stabilization in the highly rotating NBI heated plasma, the plasma rotation was reduced either by resonant n=1 braking or non-resonant n=3 braking. It was found that the feedback can sustain the plasma above no-wall limit even when the rotation outside q>2 was reduced to nearly zero. Issues related to the feedback performance improvement will be discussed.

  1. Flux Redux: The Spinning Coil Comes Around Again

    Science.gov (United States)

    Lund, Daniel; Dietz, Eric; Zou, Xueli; Ard, Christopher; Lee, Jaydie; Kaneshiro, Chris; Blanton, Robert; Sun, Steven

    2017-01-01

    An essential laboratory exercise for our lower-division electromagnetism course involves the measurement of Earth's local magnetic field from the emf induced in a rotating coil of wire. Although many methods exist for the measurement of Earth's field, this one gives our students some practical experience with Faraday's law. The apparatus we had been using previously for this activity, as has been described in TPT, is a coil driven by an electric motor at constant angular speed with its axis aligned vertically or horizontally. The emf produced was then used to calculate values for the components of the B field. Although this has produced acceptable results, the rotators have proven to be noisy, both electrically and acoustically, as well as somewhat hazardous. Additionally, the effect of stray fields from magnetic materials in the base and housing of the rotator on our measurements has not been quantitatively assessed. Now worn badly by decades of use, these units are prohibitively expensive to replace. In response to this situation, we have designed, built, and tested a quieter, greener, and more compact apparatus that can be produced cost effectively. As part of the experimental design, we have removed the constraint of constant angular rotation rate for the coil; this turns out to provide a much richer data analysis experience for students.

  2. Influence of turn-to-turn resistivity and coil geometrical size on charging characteristics of no-electrical-insulation REBCO pancake coils

    Science.gov (United States)

    Wang, Y.; Song, H.

    2016-07-01

    High temperature superconductor (HTS) no-electrical-insulation (NEI) coils demonstrate great advantages in thermal stability and self-protection features. However, an intrinsic delay is observed in the charging process and as a result there maybe a possible settle-out problem. It becomes more critical for large HTS coils with more turns, such as the magnets for the accelerator system and DC induction heater applications. This paper presents detailed studies on the charging characteristics of NEI coils. Firstly, two different no-electrical-insulation coils are wound: the first is directly wound using only REBCO tapes with brass lamination, which is called a no-insulation (NI) coil. The other one is co-wound with stainless steel (SS) strips and REBCO tapes whose copper stabilizer is electroplated, which is called a metallic insulation (MI) coil. Fast discharging tests are performed on the two coils and their equivalent turn-to-turn resistivity is calculated. A similar discharging delay is observed on both coils, but the turn-to-turn resistivity of the SS co-wound coil is much higher than that of the first coil. Then the resistivity data is directly applied to an equivalent circuit network model which is developed to predict the charging behaviours. The model calculates coil voltage, currents along the azimuthal and radial directions, as well as the induced magnetic field. A practical charging time is defined to characterize the field ramping process considering the charging delay between field ramping and current charging. The charging behaviours are extensively analyzed and compared in terms of three primary factors: equivalent turn-to-turn resistivity, coil size and ramping rate. The results show that the charging time increases dramatically with the coil size and may be too long to be practical for large-scale applications using HTS coils with low turn-to-turn resistivity. Increasing the turn-to-turn resistivity enables one to accelerate the charging process

  3. Structural and biochemical characterizations of an intramolecular tandem coiled coil protein.

    Science.gov (United States)

    Shin, Donghyuk; Kim, Gwanho; Kim, Gyuhee; Zheng, Xu; Kim, Yang-Gyun; Lee, Sangho

    2014-12-12

    Coiled coil has served as an excellent model system for studying protein folding and developing protein-based biomaterials. Most designed coiled coils function as oligomers, namely intermolecular coiled coils. However, less is known about structural and biochemical behavior of intramolecular coiled coils where coiled coil domains are covalently linked in one polypeptide. Here we prepare a protein which harbors three coiled coil domains with two short linkers, termed intramolecular tandem coiled coil (ITCC) and characterize its structural and biochemical behavior in solution. ITCC consists of three coiled coil domains whose sequences are derived from Coil-Ser and its domain swapped dimer. Modifications include positioning E (Glu) residue at "e" and K (Lys) at "g" positions throughout heptad repeats to enhance ionic interaction among its constituent coiled coil domains. Molecular modeling of ITCC suggests a compact triple helical bundle structure with the second and the third coiled coil domains forming a canonical coiled coil. ITCC exists as a mixture of monomeric and dimeric species in solution. Small-angle X-ray scattering reveals ellipsoidal molecular envelopes for both dimeric and monomeric ITCC in solution. The theoretically modeled structures of ITCC dock well into the envelopes of both species. Higher ionic strength shifts the equilibrium into monomer with apparently more compact structure while secondary structure remains unchanged. Taken together, our results suggest that our designed ITCC is predominantly monomeric structure through the enhanced ionic interactions, and its conformation is affected by the concentration of ionic species in the buffer.

  4. Future Accelerator Magnet Needs

    CERN Document Server

    Devred, Arnaud; Yamamoto, A

    2005-01-01

    Superconducting magnet technology is continually evolving in order to meet the demanding needs of new accelerators and to provide necessary upgrades for existing machines. A variety of designs are now under development, including high fields and gradients, rapid cycling and novel coil configurations. This paper presents a summary of R&D programs in the EU, Japan and the USA. A performance comparison between NbTi and Nb3Sn along with fabrication and cost issues are also discussed.

  5. CCHMM_PROF: a HMM-based coiled-coil predictor with evolutionary information

    DEFF Research Database (Denmark)

    Bartoli, Lisa; Fariselli, Piero; Krogh, Anders;

    2009-01-01

    MOTIVATION: The widespread coiled-coil structural motif in proteins is known to mediate a variety of biological interactions. Recognizing a coiled-coil containing sequence and locating its coiled-coil domains are key steps towards the determination of the protein structure and function. Different...... tools are available for predicting coiled-coil domains in protein sequences, including those based on position-specific score matrices and machine learning methods. RESULTS: In this article, we introduce a hidden Markov model (CCHMM_PROF) that exploits the information contained in multiple sequence...... alignments (profiles) to predict coiled-coil regions. The new method discriminates coiled-coil sequences with an accuracy of 97% and achieves a true positive rate of 79% with only 1% of false positives. Furthermore, when predicting the location of coiled-coil segments in protein sequences, the method reaches...

  6. Coiled-coil conformation of a pentamidine-DNA complex.

    Science.gov (United States)

    Moreno, Tadeo; Pous, Joan; Subirana, Juan A; Campos, J Lourdes

    2010-03-01

    The coiled-coil structure formed by the complex of the DNA duplex d(ATATATATAT)(2) with pentamidine is presented. The duplex was found to have a mixed structure containing Watson-Crick and Hoogsteen base pairs. The drug stabilizes the coiled coil through the formation of cross-links between neighbouring duplexes. The central part of the drug is found in the minor groove as expected, whereas the charged terminal amidine groups protrude and interact with phosphates from neighbouring molecules. The formation of cross-links may be related to the biological effects of pentamidine, which is used as an antiprotozoal agent in trypanosomiasis, leishmaniasis and pneumonias associated with AIDS. The DNA sequence that was used is highly abundant in most eukaryotic genomes. However, very few data are available on DNA sequences which only contain A.T base pairs.

  7. An EM Induction Hi-Speed Rotation Angular Rate Sensor.

    Science.gov (United States)

    Li, Kai; Li, Yuan; Han, Yan

    2017-03-17

    A hi-speed rotation angular rate sensor based on an electromagnetic induction signal is proposed to provide a possibility of wide range measurement of high angular rates. An angular rate sensor is designed that works on the principle of electromagnetism (EM) induction. In addition to a zero-phase detection technique, this sensor uses the feedback principle of magnetic induction coils in response to a rotating magnetic field. It solves the challenge of designing an angular rate sensor that is suitable for both low and high rotating rates. The sensor was examined for angular rate measurement accuracy in simulation tests using a rotary table. The results show that it is capable of measuring angular rates ranging from 1 rps to 100 rps, with an error within 1.8‰ of the full scale (FS). The proposed sensor is suitable to measurement applications where the rotation angular rate is widely varied, and it contributes to design technology advancements of real-time sensors measuring angular acceleration, angular rate, and angular displacement of hi-speed rotary objects.

  8. An EM Induction Hi-Speed Rotation Angular Rate Sensor

    Directory of Open Access Journals (Sweden)

    Kai Li

    2017-03-01

    Full Text Available A hi-speed rotation angular rate sensor based on an electromagnetic induction signal is proposed to provide a possibility of wide range measurement of high angular rates. An angular rate sensor is designed that works on the principle of electromagnetism (EM induction. In addition to a zero-phase detection technique, this sensor uses the feedback principle of magnetic induction coils in response to a rotating magnetic field. It solves the challenge of designing an angular rate sensor that is suitable for both low and high rotating rates. The sensor was examined for angular rate measurement accuracy in simulation tests using a rotary table. The results show that it is capable of measuring angular rates ranging from 1 rps to 100 rps, with an error within 1.8‰ of the full scale (FS. The proposed sensor is suitable to measurement applications where the rotation angular rate is widely varied, and it contributes to design technology advancements of real-time sensors measuring angular acceleration, angular rate, and angular displacement of hi-speed rotary objects.

  9. Performance of Upgraded Cooling System for Lhd Helical Coils

    Science.gov (United States)

    Hamaguchi, S.; Imagawa, S.; Obana, T.; Yanagi, N.; Moriuchi, S.; Sekiguchi, H.; Oba, K.; Mito, T.; Motojima, O.; Okamura, T.; Semba, T.; Yoshinaga, S.; Wakisaka, H.

    2008-03-01

    Helical coils of the Large Helical Device (LHD) are large scale superconducting magnets for heliotron plasma experiments. The helical coils had been cooled by saturated helium at 4.4 K, 120 kPa until 2005. An upgrade of the cooling system was carried out in 2006 in order to improve the cryogenic stability of the helical coils and then it has been possible to supply the coils with subcooled helium at 3.2 K, 120 kPa. A designed mass flow of the supplied subcooled helium is 50 g/s. The subcooled helium is generated at a heat exchanger in a saturated helium bath. A series of two centrifugal cold compressors with gas foil bearing is utilized to lower the helium pressure in the bath. The supplied helium temperature is regulated by rotational speed of the cold compressors and power of a heater in the bath. The mass flow of the supplied helium is also controlled manually by a supply valve and its surplus is evaporated by ten heaters at the outlet above the coils. In the present study, the performance of the cooling system has been investigated and a stable operating method has also developed. As the result, it was confirmed that the performance of the upgraded cooling system satisfies the requirements.

  10. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    Science.gov (United States)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  11. Can Magnetic Coil Ease Tinnitus?

    Science.gov (United States)

    ... Research Updates Technology Horizons Can magnetic coil ease tinnitus? VA trial aims to find out February 3, ... pain. See, for example, this 2009 review study . Tinnitus and Veterans Tinnitus has been one of the ...

  12. First coil for the SC

    CERN Multimedia

    CERN PhotoLab

    1955-01-01

    The coils for the SC magnet were stored in the large hangar of the Cointrin Airport (to make sure that they would be available before snow and ice would block the roads and canals from Belgium, where they were built).

  13. Adjustable Induction-Heating Coil

    Science.gov (United States)

    Ellis, Rod; Bartolotta, Paul

    1990-01-01

    Improved design for induction-heating work coil facilitates optimization of heating in different metal specimens. Three segments adjusted independently to obtain desired distribution of temperature. Reduces time needed to achieve required temperature profiles.

  14. D-Cysteine Ligands Control Metal Geometries within de Novo Designed Three-Stranded Coiled Coils.

    Science.gov (United States)

    Pecoraro, Vincent Louis; Ruckthong, Leela; Peacock, Anna F A; Pascoe, Cherilyn E; Hemmingsen, Lars; Stuckey, Jeanne A

    2017-04-06

    While metal ion binding to naturally occurring L-amino acid proteins is well documented, understanding the impact of the opposite chirality (D) amino acids on the structure and stereochemistry of metals is in its infancy. We examine the effect of a D-configuration cysteine within a designed L-amino acid three-stranded coiled coil in order to enforce a precise coordination number on a metal center. The D-chirality does not alter the native fold, but the side-chain reorientation modifies the sterics of the metal binding pocket. L-Cys side-chains within the coiled-coil have previously been shown to rotate substantially from their preferred positions in the apo structure to create a binding site for a tetra-coordinate metal ion. However, here we show by x-ray crystallography that D-Cys side chains are preorganized with suitable geometry to bind such a ligand. This is confirmed by comparison of the Zn(II)Cl(CSL16DC)₃²¯ to the published Zn(II)(H₂O)(GRAND-CSL12AL16LC)₃¯.¹ Spectroscopic analysis indicates that the Cd(II) geometry observed using L-Cys ligands (a mixture of 3- and 4- coordinate Cd(II)) is altered to a single 4-coordinate specie when D-Cys is present. This work opens a new avenue for the control of metal site environment in man-made proteins, by simply altering the binding ligand with its mirror imaged D-configuration. Thus, use of D amino acids in a metal's coordination sphere promises to be a powerful tool for controlling the properties of future metalloproteins.

  15. Nylon screws make inexpensive coil forms

    Science.gov (United States)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  16. Nylon screws make inexpensive coil forms

    Science.gov (United States)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  17. HELMHOLTZ COILS FOR MEASURING MAGNETIC MOMENTS

    Directory of Open Access Journals (Sweden)

    P. N. Dobrodeyev

    2013-01-01

    Full Text Available The optimal configuration of the double Helmholtz coils for measuring of the magnetic dipole moments was defined. It was determined that measuring coils should have round shape and compensative coils – the square one. Analytically confirmed the feasibility of the proposed configuration of these coils as primary transmitters of magnetic dipole moments.

  18. Three-dimensional high-inductance birdcage coil for NQR applications.

    Science.gov (United States)

    Peshkovsky, A S; Cerioni, L; Osan, T M; Avdievich, N I; Pusiol, D J

    2006-09-01

    A birdcage coil capable of operating simultaneously and independently in three orthogonal dimensions has been developed. A co-rotational end-ring mode producing an RF field in the longitudinal direction was utilized in addition to the two common transverse orthogonal modes. Two conductor turns were used for each of the coil's windows, increasing its inductance by a factor of four, thereby, making the coil suitable for low-frequency applications. Two or three-frequency detection can be easily carried out with this device. Orthogonality of the coil's channels allows arbitrarily close frequency positioning of each resonant mode, potentially useful in wide-line NQR studies, in which simultaneous excitation/detection of signals from three adjacent regions of a single wide line can be performed. The coil's performance was evaluated using a three-dimensional scheme, in which a circularly polarized experiment was combined with a linearly polarized measurement at another frequency, resulting in SNR improvement by 55%.

  19. Proto-CIRCUS tilted-coil tokamak–torsatron hybrid: Design and construction

    Energy Technology Data Exchange (ETDEWEB)

    Clark, A.W.; Doumet, M.; Hammond, K.C. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States); Kornbluth, Y. [Yeshiva University, New York, NY 10033 (United States); Spong, D.A. [Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States); Sweeney, R. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States); Volpe, F.A., E-mail: fvolpe@columbia.edu [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States)

    2014-11-15

    Highlights: • A tokamak-like device with tilted toroidal field (TF) coils needs less plasma current than a conventional tokamak. • Rotational transform is partly generated by external coils. Device can be considered a tokamak–torsatron hybrid. • We designed and constructed the first device of this type. • Tilted TF coils are interlinked to each other, which helps to reduce aspect ratio of plasma. • This is a six-coil generalization of CNT stellarator, also at Columbia University, which features two interlinked coils. - Abstract: We present the field-line modeling, design, and construction of a prototype circular-coil tokamak–torsatron hybrid called Proto-CIRCUS. The device has a major radius R = 16 cm and minor radius a < 5 cm. The six “toroidal field” coils are planar as in a tokamak, but they are tilted. This, combined with induced or driven plasma current, is expected to generate rotational transform, as seen in field-line tracing and equilibrium calculations. The device is expected to operate at lower plasma current than a tokamak of comparable size and magnetic field, which might have interesting implications for disruptions and steady-state operation. Additionally, the toroidal magnetic ripple is less pronounced than in an equivalent tokamak in which the coils are not tilted. The tilted coils are interlocked, resulting in a relatively low aspect ratio, and can be moved, both radially and in tilt angle, between discharges. This capability will be exploited for detailed comparisons between calculations and field-line mapping measurements. Such comparisons will reveal whether this relatively simple concept can generate the expected rotational transform.

  20. Lepton acceleration in the vicinity of the event horizon: High-energy and Very-high-energy emissions from rotating black holes with various masses

    CERN Document Server

    Hirotani, Kouichi; Lin, Lupin Chun-Che; Chang, Hsiang-Kuang; Inoue, Makoto; Kong, Albert K H; Matsushita, Satoki; Tam, Pak-Hin T

    2016-01-01

    We investigate the electrostatic acceleration of electrons and positrons in the vicinity of the event horizon, applying the pulsar outer-gap model to black hole magnetospheres. During a low accretion phase, the radiatively inefficient accretion flow (RIAF) cannot emit enough MeV photons that are needed to sustain the force-free magnetosphere via two-photon collisions. In such a charge-starved region (or a gap), an electric field arises along the magnetic field lines to accelerate electrons and positrons into ultra-relativistic energies. These relativistic leptons emit copious gamma-rays via curvature and inverse-Compton (IC) processes. Some of such gamma-rays collide with the submillimeter-IR photons emitted from the RIAF to materialize as pairs, which polarize to partially screen the original acceleration electric field. It is found that the gap gamma-ray luminosity increases with decreasing accretion rate. However, if the accretion rate decreases too much, the diminished RIAF soft photon field can no longer...

  1. Magnetic Field Design of Coil-Dominated Magnets Wound With Coated Conductors

    OpenAIRE

    Takahashi, Keita; Amemiya, Naoyuki; Nakamura, Taketsune; MORI, YOSHIHARU; Ogitsu, Toru; Yoshimoto, Masahiro; WATANABE, Ikuo; Yoshiyuki, Takeshi

    2012-01-01

    Coil-dominated magnets wound with coated conductors were designed for an FFAG accelerator for carbon therapy, which was designed by applying linear approximation. When designing the coil-end of the magnets, we applied differential geometry. To apply the differential geometry to three-dimensional windings with coated conductors, we introduced the concept of generalized flat-wise bending. Thereby, the combination of flat-wise bending and torsion was considered as bending of developable surface....

  2. Proposed New Test of Equivalence Principle from Rotating Bodies

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yuan-Zhong; LUO Jun; NIE Yu-Xin

    2000-01-01

    We study a new kind of equivalence principle for rotating bodies and propose a test of the equivalence principle by comparing free-fall gravitational accelerations of two gyroscopes or a rotating and a non-rotating extended bodies.

  3. Optimization and Validation of Rotating Current Excitation with GMR Array Sensors for Riveted Structures Inspection

    Directory of Open Access Journals (Sweden)

    Chaofeng Ye

    2016-09-01

    Full Text Available In eddy current non-destructive testing of a multi-layered riveted structure, rotating current excitation, generated by orthogonal coils, is advantageous in providing sensitivity to defects of all orientations. However, when used with linear array sensors, the exciting magnetic flux density ( B x of the orthogonal coils is not uniform over the sensor region, resulting in an output signal magnitude that depends on the relative location of the defect to the sensor array. In this paper, the rotating excitation coil is optimized to achieve a uniform B x field in the sensor array area and minimize the probe size. The current density distribution of the coil is optimized using the polynomial approximation method. A non-uniform coil design is derived from the optimized current density distribution. Simulation results, using both an optimized coil and a conventional coil, are generated using the finite element method (FEM model. The signal magnitude for an optimized coil is seen to be more robust with respect to offset of defects from the coil center. A novel multilayer coil structure, fabricated on a multi-layer printed circuit board, is used to build the optimized coil. A prototype probe with the optimized coil and 32 giant magnetoresistive (GMR sensors is built and tested on a two-layer riveted aluminum sample. Experimental results show that the optimized probe has better defect detection capability compared with a conventional non-optimized coil.

  4. Computational analysis of residue contributions to coiled-coil topology.

    Science.gov (United States)

    Ramos, Jorge; Lazaridis, Themis

    2011-11-01

    A variety of features are thought to contribute to the oligomeric and topological specificity of coiled coils. In previous work, we examined the determinants of oligomeric state. Here, we examine the energetic basis for the tendency of six coiled-coil peptides to align their α-helices in antiparallel orientation using molecular dynamics simulations with implicit solvation (EEF1.1). We also examine the effect of mutations known to disrupt the topology of these peptides. In agreement with experiment, ARG or LYS at a or d positions were found to stabilize the antiparallel configuration. The modeling suggests that this is not due to a-a' or d-d' repulsions but due to interactions with e' and g' residues. TRP at core positions also favors the antiparallel configuration. Residues that disfavor parallel dimers, such as ILE at d, are better tolerated in, and thus favor the antiparallel configuration. Salt bridge networks were found to be more stabilizing in the antiparallel configuration for geometric reasons: antiparallel helices point amino acid side chains in opposite directions. However, the structure with the largest number of salt bridges was not always the most stable, due to desolvation and configurational entropy contributions. In tetramers, the extent of stabilization of the antiparallel topology by core residues is influenced by the e' residue on a neighboring helix. Residues at b and c positions in some cases also contribute to stabilization of antiparallel tetramers. This work provides useful rules toward the goal of designing coiled coils with a well-defined and predictable three-dimensional structure.

  5. Physics design of a saddle coil system for TCV

    Energy Technology Data Exchange (ETDEWEB)

    Rossel, J.X., E-mail: jonathan.rossel@epfl.ch; Moret, J.-M.; Martin, Y.; Pochon, G.

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer The design of a saddle coil system for TCV is presented. Black-Right-Pointing-Pointer The system is designed for ELM control, error field correction and vertical control. Black-Right-Pointing-Pointer The issue of optimal design determination is addressed. Black-Right-Pointing-Pointer Electrical properties in the presence of a conducting wall are quantified. Black-Right-Pointing-Pointer Coil heating due to Joule effect and impact of plasma disruptions are considered. - Abstract: The upgrade project for TCV (Tokamak a Configuration Variable) includes the installation of a set of saddle coils, namely the saddle coil system (SCS), located and powered such as to create a helical magnetic perturbation. Using independent power supplies, the toroidal periodicity of this perturbation is tunable, allowing simultaneously edge localized modes (ELM) control through resonant magnetic perturbation (RMP), error field correction and vertical control. Other experimental applications, like resistive wall mode and rotation control, are also in view. In this article, the adequacy of two SCS designs, an in-vessel one and an ex-vessel one, is assessed with respect to the desired experimental applications. The current requirements and the system performances are also characterized. The conducting vessel wall is accounted for in a model used to determine the coupled response functions of the SCS, the screening of the magnetic perturbation by the wall, the induced voltages and currents during a plasma disruption and the maximal magnetic forces exerted on the SCS. A scaling of the SCS parameters with the number of coil turns is presented and the issue of coil heating and cooling is discussed.

  6. A rotating quantum vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Lorenci, V.A. de; Svaiter, N.F. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    1996-11-01

    It was investigated which mapping has to be used to compare measurements made in a rotating frame to those made in an inertial frame. Using a non-Galilean coordinate transformation, the creation-annihilation operators of a massive scalar field in the rotating frame are not the same as those of an inertial observer. This leads to a new vacuum state(a rotating vacuum) which is a superposition of positive and negative frequency Minkowski particles. Polarization effects in circular accelerators in the proper frame of the electron making a connection with the inertial frame point of view were analysed. 65 refs.

  7. Comparison of the peak resolution and the stationary phase retention between the satellite and the planetary motions using the coil satellite centrifuge with counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives.

    Science.gov (United States)

    Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro

    2017-01-20

    -hexane/ethyl acetate/1-butanol/methanol/water system at different volume ratios. In the satellite motion at (ω1, ω2, ω3)=(300, 150, 150rpm), almost constant stationary phase retention was obtained with the lower mobile phase regardless of the hydrophobicity of the solvent system whereas the stationary phase retention varied according to the volume ratio of the two-phase solvent system for the upper mobile phase. However, stable stationary phase retention was observed with either phase used as the mobile phase. In order to analyze the acceleration acting on the coiled column, an acceleration sensor was set on the column holder by displacing the multilayer column. The combination of the rotation speeds at (300, 100, 200rpm) showed double loops in the acceleration track, whereas (300, 150, 150rpm) showed a single loop, and all other combinations showed, complex tracks. The overall results indicate that the satellite motion is seriously affected by the combination of rotation speeds and the hydrophobicity of the two-phase solvent system when the upper phase was used as the mobile phase for separation.

  8. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, Christophe; Fish, Alexander [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands); Pefani, Dafni-Eleftheria; Taraviras, Stavros; Lygerou, Zoi [University of Patras, 26505 Rio, Patras (Greece); Perrakis, Anastassis, E-mail: a.perrakis@nki.nl [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands)

    2015-10-31

    The GemC1 coiled-coil structure has subtle differences compared with its homologues Geminin and Idas. Co-expression experiments in cells and biophysical stability analysis of the Geminin-family coiled coils suggest that the GemC1 coiled coil alone is unstable. GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and the Geminin–Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.

  9. A Rotating Quantum Vacuum

    CERN Document Server

    De Lorenci, V A

    1996-01-01

    We investigate which mapping we have to use to compare measurements made in a rotating frame to those made in an inertial frame. Using a "Lorentz-like" coordinate transformation we obtain that creation-anihilation operators of a massless scalar field in the rotating frame are not the same as those of an inertial observer. This leads to a new vacuum state (a rotating vacuum) which is a superposition of positive and negative frequency Minkowski particles. After this, introducing an apparatus device coupled linearly with the field we obtain that there is a strong correlation between number of rotating particles (in a given state) obtained via canonical quantization and via response function of the rotating detector. Finally, we analyse polarization effects in circular accelerators in the proper frame of the electron making a connection with the inertial frame point of view.

  10. Deformation of Linked Polymer Coils

    Institute of Scientific and Technical Information of China (English)

    董朝霞; 李明远; 吴肇亮; 林梅钦

    2003-01-01

    Linked polymer solution (LPS) is defined as the solution of linked polymer coils (LPCs) dispersed in water, composed of low concentration partially hydrolyzed polyacrylamide (HPAM) and aluminum citrate (crosslinker). In the work, the conformational changes of LPCs under different conditions were investigated by the methods of membrane filtering under low pressure, dynamic light scattering and core flooding experiments. The results showed that in some conditions the LPCs could be compressed mechanically to 1/158.5 of their original volume because of relatively lower HPAM cross-linking. The hydration property of LPCs was similar to that of normal polymer coils. The deformation of LPCs was more restricted than that of ordinary polymer coils under the flow shear stress or the shift of hydration equilibrium caused in the variation of the electrolyte concentration which is responsible for the effective plugging in the throats of porous media when LPCs are used for deep diverting.

  11. A Novel Permanent Magnetic Angular Acceleration Sensor

    OpenAIRE

    Hao Zhao; Hao Feng

    2015-01-01

    Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it h...

  12. Coil Optimization for HTS Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech

    for different tape parameters Ici, ni and Ci, where Ici, ni and Ci are critical current, n - value and price of the ith tape respectively and i=1, 2, 3…, further optimization with respect to cost vs. HTS losses has been performed. Allowing for different types of HTS tapes in the coils, a guidance to which tape....... The proposed coil design is optimized with respect to minimizing the perpendicular field while still maximizing the amplitude of fundamental space harmonic. This guarantees the lowest HTS loss density and best utilization of expensive HTS material in the field winding of the SM. Additionally, accounting...

  13. Superconducting Accelerator Magnets

    CERN Document Server

    Mess, K H; Wolff, S

    1996-01-01

    The main topic of the book are the superconducting dipole and quadrupole magnets needed in high-energy accelerators and storage rings for protons, antiprotons or heavy ions. The basic principles of low-temperature superconductivity are outlined with special emphasis on the effects which are relevant for accelerator magnets. Properties and fabrication methods of practical superconductors are described. Analytical methods for field calculation and multipole expansion are presented for coils without and with iron yoke. The effect of yoke saturation and geometric distortions on field quality is studied. Persistent magnetization currents in the superconductor and eddy currents the copper part of the cable are analyzed in detail and their influence on field quality and magnet performance is investigated. Superconductor stability, quench origins and propagation and magnet protection are addressed. Some important concepts of accelerator physics are introduced which are needed to appreciate the demanding requirements ...

  14. 1999 Review of superconducting dipole and quadrupole magnets for particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Devred, A. [CEA/Saclay, Dept. d' Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l' Instrumentation Associee (DAPNIA), 91 - Gif-sur-Yvette (France); CERN, Conseil Europeen pour la recherche nucleaire, Laboratoire europeen pour la physique des particules Geneve (Switzerland)

    1999-12-01

    conductor positioning (section 6). We also show how these concepts have evolved in time to accommodate higher and higher Lorentz forces. We follow by presenting the complex formalism used to describe magnetic measurement systems based on rotating pick-up coil arrays (section 7), and we summarize the various sources of field errors (section 8). Finally, after describing the cooling schemes that have been implemented in large superconducting particle accelerators (section 9), we discuss issues related to quench performance (section 10) and to quench protection (section 11). (authors)

  15. [Two Cases of Ruptured Cerebral Aneurysm Complicated with Delayed Coil Protrusion after Coil Embolization].

    Science.gov (United States)

    Furukawa, Takashi; Ogata, Atsushi; Ebashi, Ryo; Takase, Yukinori; Masuoka, Jun; Kawashima, Masatou; Abe, Tatsuya

    2016-07-01

    We report two cases of delayed coil protrusion after coil embolization for ruptured cerebral aneurysms. Case 1:An 82-year-old woman with a subarachnoid hemorrhage due to a ruptured small anterior communicating artery aneurysm underwent successful coil embolization. Eighteen days after the procedure, coil protrusion from the aneurysm into the right anterior cerebral artery was observed without any symptoms. Further coil protrusion did not develop after 28 days. Case 2:A 78-year-old woman with a subarachnoid hemorrhage due to a ruptured small left middle cerebral artery aneurysm underwent successful coil embolization. Twenty days after the procedure, coil protrusion from the aneurysm into the left middle cerebral artery was observed, with a transient ischemic attack. Further coil protrusion did not develop. Both patients recovered with antithrombotic treatment. Even though delayed coil protrusion after coil embolization is rare, it should be recognized as a long-term complication of coil embolization for cerebral aneurysms.

  16. Coupled Coils, Magnets and Lenz's Law

    Science.gov (United States)

    Thompson, Frank

    2010-01-01

    Great scientists in the past have experimented with coils and magnets. Here we have a variation where coupling occurs between two coils and the oscillatory motion of two magnets to give somewhat surprising results. (Contains 6 figures and 1 footnote.)

  17. Generalization of Helmholtz coil problem

    Directory of Open Access Journals (Sweden)

    Petković Dejan M.

    2015-01-01

    Full Text Available The primary intent of this work is to propose a simple analytical method for designing coil systems for homogeneous and gradient magnetostatic field generation. Coil system consists of two identical coaxial (regular polygonal current loops. In the space between the loops, there is nearly homogeneous or nearly linear distribution of the magnetic field along the axes depending on the currents' direction. First, we derived a suitable, simple and general expression for the magnetic field along the axes due to a polygonal current loop. We emphasize the importance of the role of this expression for further analysis. The total on-axes magnetic field is the result of superposition of the magnetic fields that each loop generates separately. The proper distance between the loops and the current orientation make the system to become either Helmholtz coil or anti-Helmholtz coil. In this paper we give exact, analytical and general expression for this optimal distance that provides the magnetic field to be homogeneous (linear as much as possible. We based our study on Taylor series expansion of the total magnetic field, demanding that the first contaminating term must be canceled, in both, symmetric and asymmetric case.

  18. Rotor assembly including superconducting magnetic coil

    Energy Technology Data Exchange (ETDEWEB)

    Snitchler, Gregory L. (Shrewsbury, MA); Gamble, Bruce B. (Wellesley, MA); Voccio, John P. (Somerville, MA)

    2003-01-01

    Superconducting coils and methods of manufacture include a superconductor tape wound concentrically about and disposed along an axis of the coil to define an opening having a dimension which gradually decreases, in the direction along the axis, from a first end to a second end of the coil. Each turn of the superconductor tape has a broad surface maintained substantially parallel to the axis of the coil.

  19. A study on electromagnetic and mechanical characteristics of the field coil in HTS motor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.B., E-mail: kim@elec.okayama-u.ac.j [Department of Electrical and Electronic Engineering, Okayama University, 3-1-1, Tsushima Naka, Kita-ku, Okayama 700-8530 (Japan); Kadota, T.; Joo, J.H.; Sano, H.; Murase, S. [Department of Electrical and Electronic Engineering, Okayama University, 3-1-1, Tsushima Naka, Kita-ku, Okayama 700-8530 (Japan); Lee, S.H.; Hong, J.P. [Department of Automotive Engineering, Hanyang University, 17, Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Kim, H.M.; Kwon, Y.K.; Jo, Y.S. [Korea Electrotechnology Research Institute, 28-1, Seongju-dong, Changwon 641-120 (Korea, Republic of)

    2010-11-01

    High temperature superconducting (HTS) motors electromagnetically consist of a rotator wound with HTS wires and an armature with conventional copper wires like Litz wire. The HTS rotor windings, as field coils, consist of a straight part and an end-ring part. Because a major rotation torque is induced by an interaction between magnetic fields and current-carrying conductors in the straight part, most of mechanical stresses in the motor occur at the straight part. An end-ring is placed in the edge of the straight part and used to connect to each adjacent straight-part coils. The magnetic fields by coil currents concentrate on the end-ring part, therefore, it is expected that the critical current of the entire coil, straight and end-ring, can be determined by the magnitude of the field in the end-ring. This paper deals with the overall J{sub c} degradation in the end-ring part by self-field generated from the coil. In addition to electromagnetic analyses, we have performed a numerical analysis in order to evaluate mechanical stresses in the straight part of field coil by armature reaction on steady-state operation. The analytical results will be presented in this paper.

  20. Studies of a thermal energy storage unit with ice on coils; Ice on coil gata kori chikunetsuso no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan)

    1996-10-27

    Study was made of an ice-on-coil heat storage tank for power load levelling. Prior to the prediction of performance of the system as a whole, the performance of the heat storage tank itself needs to be predicted. A brine (35.9% water solution of ethylene glycol) cooled by a refrigerating machine was poured from the upper end of the piping in the heat storage tank (consisting of 19 spiral pipes or coils arranged in parallel in the vertical direction) for the collection of ice around the coils. Ice grew thicker with the passage of time but there was no remarkable decrease in the transfer of heat because there was an increase in the area of contact between ice and water, and the brine exit temperature remained constant over a prolonged period of time. There was a close agreement between experiment results and theoretical conclusions throughout the heat accumulation process, including changes with time in the thickness of ice on the coils, all pointing to the appropriateness of this analytical effort. To melt the ice, water was poured into the tank top at a predetermined rate. Water chilly at 2-4{degree}C was recovered at the tank bottom, stable in the amount produced. As for the use of spiral pipes for making ice, the laminar heat transfer rate in such pipes are supposed to be more than two times higher than that in straight pipes, and this was quite effective in accelerating heat transfer. 7 refs., 11 figs.

  1. Coil motion effects in watt balances: a theoretical check

    Science.gov (United States)

    Li, Shisong; Schlamminger, Stephan; Haddad, Darine; Seifert, Frank; Chao, Leon; Pratt, Jon R.

    2016-04-01

    A watt balance is a precision apparatus for the measurement of the Planck constant that has been proposed as a primary method for realizing the unit of mass in a revised International System of Units. In contrast to an ampere balance, which was historically used to realize the unit of current in terms of the kilogram, the watt balance relates electrical and mechanical units through a virtual power measurement and has far greater precision. However, because the virtual power measurement requires the execution of a prescribed motion of a coil in a fixed magnetic field, systematic errors introduced by horizontal and rotational deviations of the coil from its prescribed path will compromise the accuracy. We model these potential errors using an analysis that accounts for the fringing field in the magnet, creating a framework for assessing the impact of this class of errors on the uncertainty of watt balance results.

  2. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif

    DEFF Research Database (Denmark)

    Céspedes, Nora; Habel, Catherine; Lopez-Perez, Mary

    2014-01-01

    Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous...

  3. The many types of interhelical ionic interactions in coiled coils - an overview.

    Science.gov (United States)

    Meier, Markus; Stetefeld, Jörg; Burkhard, Peter

    2010-05-01

    Coiled coils represent the most frequent protein oligomerization motif in nature and are involved in many important biological processes. The prototype interhelical ionic interaction for coiled coils described in literature is an i to i+5 ionic interaction from heptad position g to e', but other possible ionic interactions have also been described. Here we use a statistical approach to systematically analyze all high-quality coiled-coil structures in the RCSB protein database for their interhelical ionic interactions. We provide a complete listing of all possible arrangements and analyze the frequency of their occurrence in the primary sequence together with their probability of formation in the quaternary structure of the coiled coils. We show that the classical i to i+5 ionic interaction is indeed characteristic for parallel dimeric and trimeric coiled coils. But we also show that there are many more i to i+2 ionic interactions in parallel tetrameric and pentameric coiled coils, and in antiparallel coiled coils the classical i to i+5 ionic interaction is in none of the oligomerizations states the most frequently observed ionic interaction. We also demonstrate that many ionic interactions involve residues at the core positions that are usually occupied by hydrophobic residues and that such interhelical ionic interactions are a hallmark feature of dimeric coiled coils.

  4. Design of a shielded coil element of a matrix gradient coil

    Science.gov (United States)

    Jia, Feng; Littin, Sebastian; Layton, Kelvin J.; Kroboth, Stefan; Yu, Huijun; Zaitsev, Maxim

    2017-08-01

    The increasing interest in spatial encoding with non-linear magnetic fields has intensified the need for coils that generates such fields. Matrix coils consisting of multiple coil elements appear to offer a high flexibility in generating customized encoding fields and are particularly promising for localized high resolution imaging applications. However, coil elements of existing matrix coils were primarily designed and constructed for better shimming and therefore are not expected to achieve an optimal performance for local spatial encoding. Moreover, eddy current properties of such coil elements were not fully explored. In this work, an optimization problem is formulated based on the requirement of local non-linear encoding and eddy current reduction that results in novel designs of coil elements for an actively-shielded matrix gradient coil. Two metrics are proposed to assess the performance of different coil element designs. The results are analyzed to reveal new insights into coil element design.

  5. Repeats in transforming acidic coiled-coil (TACC) genes.

    Science.gov (United States)

    Trivedi, Seema

    2013-06-01

    Transforming acidic coiled-coil proteins (TACC1, 2, and 3) are essential proteins associated with the assembly of spindle microtubules and maintenance of bipolarity. Dysregulation of TACCs is associated with tumorigenesis, but studies of microsatellite instability in TACC genes have not been extensive. Microsatellite or simple sequence repeat instability is known to cause many types of cancer. The present in silico analysis of SSRs in human TACC gene sequences shows the presence of mono- to hexa-nucleotide repeats, with the highest densities found for mono- and di-nucleotide repeats. Density of repeats is higher in introns than in exons. Some of the repeats are present in regulatory regions and retained introns. Human TACC genes show conservation of many repeat classes. Microsatellites in TACC genes could be valuable markers for monitoring numerical chromosomal aberrations and or cancer.

  6. Vestibulo-Oculomotor Reflex Recording Using the Scleral Search Coil Technique. Review of Peripheral Vestibular Disorders

    Science.gov (United States)

    Boleas-Aguirre, Marisol; Migliaccio, Amerio A.; Carey, John P.

    2010-01-01

    Our goal is to review vestibulo-oculomotor reflex (VOR) studies on several peripheral vestibular disorders (Ménière’s disease, vestibular neuritis, benign paroxysmal positional vertigo, superior canal dehiscence syndrome, and vestibular neuroma), using the scleral search coil (SSC) technique. Head movements are detected by vestibular receptors and the elicited VOR is responsible for compensatory 3 dimensional eye movements. Therefore, to study the VOR it is necessary to assess the direction and velocity of 3 dimensional head, and eye movements. This can be achieved using the SSC technique. Interaction between a scleral search coil and an alternating magnetic field generates an electrical signal that is proportional to eye position. Ideally, eye rotation axis is aligned with head rotation axis and VOR gain (eye velocity/head velocity) for horizontal and vertical head rotations is almost 1. The VOR gain, however, for torsional head rotations is smaller and about 0.7. PMID:17683700

  7. A Experimental and Computational Study of Flow Instability in a Helical Coil.

    Science.gov (United States)

    Webster, Donald Robert

    This study concerns the transitional regime between laminar and turbulent flow states in a helically coiled pipe of circular cross-section. The study consists of complementary experimental measurements and numerical calculations in a coil with a radius of curvature to pipe radius ratio (R_{rm c}/a) equal to 18.2. A new test section and flow apparatus were constructed. The streamwise pressure drop measurements agreed very well with those of previous investigations. Laser-Doppler velocimetry (LDV) measurements of two instantaneous velocity components were obtained along the midplane of the pipe cross-section at a nominally fully developed location in the coil. Thirteen Reynolds numbers were examined in the range 3800 laminar, transitional, and turbulent flow regimes. In the range 5060 flow oscillations (at St = 0.25 and 0.5) in the inner half of the pipe cross-section due to a traveling wave instability. Similar low frequency unsteadiness was not observed near the outer wall. A significant local maximum in the rms velocity was observed near the pipe center for Re > 5060 and is attributed to the velocity perturbation of the traveling wave instability. Still photographs and video images of the flow visualization by means of a dye streak in the range 5060 flow is turbulent beyond this range. The CUTEFLOWS algorithm was modified to solve numerically the finite difference approximation of the Navier-Stokes equations formulated for the toroidal coordinate system. The unsteady three-dimensional calculations were performed for Re = 5480 (De = 1280). The mean characteristics of the flow predicted by the calculations agree very well with the experimental data. The flow perturbation due to the traveling wave agrees qualitatively for all three grid refinements and with the experimental data. The calculated results indicate that energy is transferred to the traveling wave from the mean flow through a complex interaction between the centripetal acceleration in the inner half of

  8. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  9. LARP Long Nb3Sn Racetrack Coil Program

    Energy Technology Data Exchange (ETDEWEB)

    Wanderer, P.; Ambrosio, G.; Anerella, M.; Barzi, E.; Bossert, R.; Cheng, D.; Cozzolino, J.; Escallier, J.; Ferracin, P.; Ganetis, G.; Ghosh, A. K.; Gupta, R. C.; Hafalia, A. R.; Hannaford, C. R.; Joshi, P.; Kovach, P.; Lietzke, A. F.; Louie, W.; Marone, A.; McInturff, A. D.; Muratore, J.; Nobrega, F.; Schmalzle, J.; Thomas, R.; Turrioni, D.

    2007-06-01

    Development of high-performance Nb{sub 3}Sn quadrupoles is one of the major goals of the LHC Accelerator Research Program (LARP). As part of this program, long racetrack magnets are being made in order to check that the change in coil length that takes place during reaction is correctly accounted for in the quadrupole design and to check for length effects in implementing the 'shell' method of coil support. To check the racetrack magnet manufacturing plan, a short racetrack magnet is being made. This magnet will be the first to use restack-rod process Nb{sub 3}Sn, making it a 'long sample' test vehicle for this new material. The paper reports the reaction and characterization of the Nb{sub 3}Sn, and construction features and test results from the short racetrack magnet. The paper also reports on the status of the construction of the first long racetrack magnet.

  10. A 16-channel receive, forced current excitation dual-transmit coil for breast imaging at 7T.

    Directory of Open Access Journals (Sweden)

    Samantha By

    Full Text Available To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE multi channel transmit.A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7 T. Signal-to-noise ratio (SNR maps, g-factor maps, and high spatial and temporal resolution in vivo images were acquired to demonstrate the utility of the coil architecture.The dual-transmit FCE coil provided homogeneous excitation and the array provided an increase in average SNR of 3.3 times (max 10.8, min 1.5 compared to the volume coil in transmit/receive mode. High resolution accelerated in vivo breast imaging demonstrated the ability to achieve isotropic spatial resolution of 0.5 mm within clinically relevant 90 s scan times, as well as the ability to perform 1.0 mm isotropic resolution imaging, 7 s per dynamics, with the use of bidirectional SENSE acceleration of up to R = 9.The FCE design of the transmit coil easily accommodates the addition of a sixteen channel array coil. The improved spatial and temporal resolution provided by the high-field array coil with FCE dual-channel transmit will ultimately be beneficial in lesion detection and characterization.

  11. Structured Light-Based Motion Tracking in the Limited View of an MR Head Coil

    DEFF Research Database (Denmark)

    Erikshøj, M.; Olesen, Oline Vinter; Conradsen, Knut

    2013-01-01

    of the facial surface. The point clouds are continuously realigned to a reference scan to obtain pose estimates. The system has been tested on a mannequin head performing controlled rotational and translational axial movements within the head coil outside the range of the magnetic field. The RMS of the residual...... error of the rotation was 0.11° and the RMS difference in the translation with the control system was 0.17 mm, within the trackable range of movement....

  12. Transitions in turbulent rotating convection

    Science.gov (United States)

    Rajaei, Hadi; Alards, Kim; Kunnen, Rudie; Toschi, Federico; Clercx, Herman; Fluid Dynamics Lab Team

    2015-11-01

    This study aims to explore the flow transition from one state to the other in rotating Rayleigh-Bènard convection using Lagrangian acceleration statistics. 3D particle tracking velocimetry (3D-PTV) is employed in a water-filled cylindrical tank of equal height and diameter. The measurements are performed at the center and close to the top plate at a Rayleigh number Ra = 1.28e9 and Prandtl number Pr = 6.7 for different rotation rates. In parallel, direct numerical simulation (DNS) has been performed to provide detailed information on the boundary layers. We report the acceleration pdfs for different rotation rates and show how the transition from weakly to strongly rotating Rayleigh-Bènard affects the acceleration pdfs in the bulk and boundary layers. We observe that the shapes of the acceleration PDFs as well as the isotropy in the cell center are largely unaffected while crossing the transition point. However, acceleration pdfs at the top show a clear change at the transition point. Using acceleration pdfs and DNS data, we show that the transition between turbulent states is actually a boundary layer transition between Prandtl-Blasius type (typical of non-rotating convection) and Ekman type.

  13. A 22-channel receive array with Helmholtz transmit coil for anesthetized macaque MRI at 3 T.

    Science.gov (United States)

    Janssens, Thomas; Keil, Boris; Serano, Peter; Mareyam, Azma; McNab, Jennifer A; Wald, Lawrence L; Vanduffel, Wim

    2013-11-01

    The macaque monkey is an important model for cognitive and sensory neuroscience that has been used extensively in behavioral, electrophysiological, molecular and, more recently, neuroimaging studies. However, macaque MRI has unique technical differences relative to human MRI, such as the geometry of highly parallel receive arrays, which must be addressed to optimize imaging performance. A 22-channel receive coil array was constructed specifically for rapid high-resolution anesthetized macaque monkey MRI at 3 T. A local Helmholtz transmit coil was used for excitation. Signal-to-noise ratios (SNRs) and noise amplification for parallel imaging were compared with those of single- and four-channel receive coils routinely used for macaque MRI. The 22-channel coil yielded significant improvements in SNR throughout the brain. Using this coil, the SNR in peripheral brain was 2.4 and 1.7 times greater than that obtained with single- or four-channel coils, respectively. In the central brain, the SNR gain was 1.5 times that of both the single- and four-channel coils. Finally, the performance of the array for functional, anatomical and diffusion-weighted imaging was evaluated. For all three modalities, the use of the 22-channel array allowed for high-resolution and accelerated image acquisition.

  14. Performance evaluation of matrix gradient coils.

    Science.gov (United States)

    Jia, Feng; Schultz, Gerrit; Testud, Frederik; Welz, Anna Masako; Weber, Hans; Littin, Sebastian; Yu, Huijun; Hennig, Jürgen; Zaitsev, Maxim

    2016-02-01

    In this paper, we present a new performance measure of a matrix coil (also known as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly considering target encoding fields. An optimization problem based on a joint optimization for the non-linear encoding fields is formulated. Based on the derived objective function, a figure of merit of a matrix coil is defined, which is a generalization of a previously known resistive figure of merit for traditional gradient coils. A cylindrical matrix coil design with a high number of elements is used to illustrate the proposed performance measure. The results are analyzed to reveal novel features of matrix coil designs, which allowed us to optimize coil parameters, such as number of coil elements. A comparison to a scaled, existing multi-coil is also provided to demonstrate the use of the proposed performance parameter. The assessment of a matrix gradient coil profits from using a single performance parameter that takes the local encoding performance of the coil into account in relation to the dissipated power.

  15. On Accelerated Black Holes

    CERN Document Server

    Letelier, P S; Letelier, Patricio S.; Oliveira, Samuel R.

    1998-01-01

    The C-metric is revisited and global interpretation of some associated spacetimes are studied in some detail. Specially those with two event horizons, one for the black hole and another for the acceleration. We found that the spacetime fo an accelerated Schwarzschild black hole is plagued by either conical singularities or lack of smoothness and compactness of the black hole horizon. By using standard black hole thermodynamics we show that accelerated black holes have higher Hawking temperature than Unruh temperature. We also show that the usual upper bound on the product of the mass and acceleration parameters (<1/sqrt(27)) is just a coordinate artifact. The main results are extended to accelerated Kerr black holes. We found that they are not changed by the black hole rotation.

  16. Echo planar diffusion-weighted imaging: possibilities and considerations with 12- and 32-channel head coils.

    Science.gov (United States)

    Morelli, John N; Saettele, Megan R; Rangaswamy, Rajesh A; Vu, Lan; Gerdes, Clint M; Zhang, Wei; Ai, Fei

    2012-01-01

    Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The utility of single-shot (ss) and an approach to readout-segmented (rs) echo planar imaging (EPI) are examined using both head coils. Substantial image quality improvements are found with rs-EPI. Imaging with a 32-channel head coil allows for implementation of greater parallel imaging acceleration factors or acquisition of scans at a higher resolution. Specifically, higher resolution imaging with rs-EPI can be achieved by increasing the number of readout segments without increasing echo-spacing or echo time to the degree necessary with ss-EPI - a factor resulting in increased susceptibility artifact and reduced signal-to-noise with the latter.

  17. Echo Planar Diffusion-Weighted Imaging: Possibilities and Considerations with 12- and 32-Channel Head Coils

    Directory of Open Access Journals (Sweden)

    John N Morelli

    2012-01-01

    Full Text Available Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The utility of single-shot (ss and an approach to readout-segmented (rs echo planar imaging (EPI are examined using both head coils. Substantial image quality improvements are found with rs-EPI. Imaging with a 32-channel head coil allows for implementation of greater parallel imaging acceleration factors or acquisition of scans at a higher resolution. Specifically, higher resolution imaging with rs-EPI can be achieved by increasing the number of readout segments without increasing echo-spacing or echo time to the degree necessary with ss-EPI - a factor resulting in increased susceptibility artifact and reduced signal-to-noise with the latter.

  18. Design and evaluation of coils for a 50 mm diameter induction coilgun launcher

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Shokair, I.R.; Wavrik, R.W. [Sandia National Labs., Albuquerque, NM (United States); Dempsey, J.F.; Honey, W.E.; Shimp, K.J. [EG and G, Inc., Albuquerque, NM (United States); Douglas, G.M. [Rockwell Power Systems Co., Albuquerque, NM (United States)

    1993-12-31

    Coilguns have the ability to provide magnetic pressure to projectiles which results in near constant acceleration. However, to achieve this performance and control projectile hearing, significant constraints are placed on the design of the coils. We are developing coils to produce an effective projectile base pressure of 100 MPa (1kbar) as a step toward reaching base pressures of 200 MPa. The design uses a scalable technology applicable to the entire range of breech to muzzle coils of a multi-stage launcher. This paper presents the design of capacitor-driven coils for launching nominal 50 mm, 350 gram projectiles. Design criteria, constraints, mechanical stress analysis, launcher performance, and test results are discussed.

  19. Construction and Test of 3.5 m Nb3Sn Racetrack Coils for LARP.

    Energy Technology Data Exchange (ETDEWEB)

    Wanderer,P.; Ambrosio, G.; Anerella, M.; Barzi, E.; Bossert, R.; Caspi, S.; Cheng, D.W.; Cozzolino, J.; Dietderich, D.R.; Escallier, J.; Feher, S.; Ferracin, P.; Ganetis, G.; Ghosh, A.K.; Gupta, R.C.; Hafalia, A.R.; Hannaford, C.R.; Joshi, P.; Kovach, P.; Lietzke, A.F.; Lizarazo, J.; Louie, W.; Marone, A.; McInturff, A.D.; Muratore, J.; Nobrega, R.; Sabbi, G.; Schmalzle, J.; Thomas, R.; Turrioni, D.

    2007-08-27

    Development of high-performance Nb{sub 3}Sn quadrupoles is one of the major goals of the LHC Accelerator Research Program (LARP). As part of this program, long racetrack magnets were made in order to check the fabrication steps for long Nb{sub 3}Sn coils, that the changes in coil length that take place during reaction and cooldown are correctly accounted for in the quadrupole design, and the use of a long aluminum shell for the support structure. This paper reports the construction of the first long Nb{sub 3}Sn magnet with racetrack coils 3.6 m long. The magnet reached a nominal 'plateau' at 9596 A after five quenches. This is about 90% of the estimated conductor limit. The peak field in the coils at this current was 11 T.

  20. Construction and Test of 3.6 m Nb3Sn Racetrack Coils for LARP

    Energy Technology Data Exchange (ETDEWEB)

    Wanderer, P.; Ambrosio, G.; Anerella, M.; Barzi, E.; Bossert, R.; Caspi, S.; Cheng, D. W.; Cozzolino, J.; Dietderich, D.R.; Escallier, J.; Feher, S.; Ferracin, P.; Ganetis, G.; Ghosh, A. K.; Gupta, R. C.; Hafalia,, A. R.; Hannaford, C. R.; Joshi, P.; Kovach, P.; Lietzke, A. F.; Lizarazo, J.; Louie, W.; Marone, A.; McInturff, A.D.; Muratore, J.; Nobrega, F.; Sabbi, G.; Schmalzle, J.; Thomas, R.; Turrioni, D.

    2008-06-01

    Development of high-performance Nb{sub 3}Sn quadrupoles is one of the major goals of the LHC Accelerator Research Program (LARP). As part of this program, long racetrack magnets were made in order to check the fabrication steps for long Nb{sub 3}Sn coils, that the changes in coil length that take place during reaction and cooldown are correctly accounted for in the quadrupole design, and the use of a long aluminum shell for the support structure. This paper reports the construction of the first long Nb{sub 3}Sn magnet with racetrack coils 3.6 m long. The magnet reached a nominal 'plateau' at 9596 A after five quenches. This is about 90% of the estimated conductor limit. The peak field in the coils at this current was 11 T.

  1. Quenching in coupled adiabatic coils

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.E.C.

    1985-03-01

    The prediction of the effects of a quench on stress and temperature is an important aspect of the design of superconducting magnets. Of particular interest, and the exclusive topic of this study, is the prediction of the effects of quenching in coupled adiabatic coils, such as the multi-section windings of a high field NMR spectrometer magnet. The predictive methods used here are based on the measurement of the time of propagation of quench between turns. From this measurement an approximate algorithum for the propagation time is used in a code which solves the linear differential equations for the coil currents and calculates the movement of normal zone boundaries and hence the associated winding resistance.

  2. Starch gelatinization in coiled heaters.

    Science.gov (United States)

    Kelder, J D H; Ptasinski, K J; Kerkhof, P J A M

    2004-01-01

    A gelatinizing model food derived from a 5% w/w cross-linked waxy maize starch suspension was simulated in coiled heaters to assess the impact of centrifugal forces on flow and heat transfer. For four coil diameters (D = 0.25, 1, 2.5, and infinity m) and three flow rates (w = 0.5, 1, and 2 m/s), heat transfer, viscous development, and the severity of channeling were evaluated. Increasing curvature proved to suppress channeling as a result of more uniform heating and gelatinization. The maximum attainable viscosity was also higher, implying a lower starch consumption for a target viscosity. Higher flow rates necessitated longer heaters, and the maximum viscosity decreased. Moderate product velocities are therefore recommended.

  3. Coiled transmission line pulse generators

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Kenneth Fox (Columbia, MO)

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  4. Self-correction coil: operation mechanism of self-correction coil

    Energy Technology Data Exchange (ETDEWEB)

    Hosoyama, K.

    1983-06-01

    We discuss here the operation mechanism of self-correction coil with a simple model. At the first stage, for the ideal self-correction coil case we calculate the self-inductance L of self-correction coil, the mutual inductance M between the error field coil and the self-correction coil, and using the model the induced curent in the self-correction coil by the external magnetic error field and induced magnetic field by the self-correction coil. And at the second stage, we extend this calculation method to non-ideal self-correction coil case, there we realize that the wire distribution of self-correction coil is important to get the high enough self-correction effect. For measure of completeness of self-correction effect, we introduce the efficiency eta of self-correction coil by the ratio of induced magnetic field by the self-correction coil and error field. As for the examples, we calculate L, M and eta for two cases; one is a single block approximation of self-correction coil winding and the other is a two block approximation case. By choosing the adequate angles of self-correction coil winding, we can get about 98% efficiency for single block approximation case and 99.8% for two block approximation case. This means that by using the self-correction coil we can improve the field quality about two orders.

  5. Test Results of HTS Coil and Magnet R&D for RIA

    CERN Document Server

    Gupta, Ramesh C; Harrison, Michael; Sampson, William; Schmalzle, Jesse D; Zeller, Al

    2005-01-01

    Brookhaven National Laboratory is developing quadrupole magnets for the proposed Rare Isotope Accelerator (RIA) based on commercially available High Temperature Superconductors (HTS). These quadrupoles will be used in the Fragment Separator region and are one of the more challenging elements in the RIA proposal. They will be subjected to several orders of magnitude more energy and radiation deposition than typical beam line and accelerator magnets receive during their entire lifetime. The proposed quadrupoles will operate in the 20-40 K temperature range for efficient heat removal. HTS coils that have been tested so far indicate that the coils meet the magnetic field requirements of the design. We will report the test results of about 10 HTS coils and of a magnetic mirror configuration that simulates the magnetic field and Lorentz force in the proposed quadrupole. In addition, the preliminary design of an HTS dipole magnet for the Fragment Separator region will also be presented.

  6. High performance 3-coil wireless power transfer system for the 512-electrode epiretinal prosthesis.

    Science.gov (United States)

    Zhao, Yu; Nandra, Mandheerej; Yu, Chia-Chen; Tai, Yu-chong

    2012-01-01

    The next-generation retinal prostheses feature high image resolution and chronic implantation. These features demand the delivery of power as high as 100 mW to be wireless and efficient. A common solution is the 2-coil inductive power link, used by current retinal prostheses. This power link tends to include a larger-size extraocular receiver coil coupled to the external transmitter coil, and the receiver coil is connected to the intraocular electrodes through a trans-sclera trans-choroid cable. In the long-term implantation of the device, the cable may cause hypotony (low intraocular pressure) and infection. However, when a 2-coil system is constructed from a small-size intraocular receiver coil, the efficiency drops drastically which may induce over heat dissipation and electromagnetic field exposure. Our previous 2-coil system achieved only 7% power transfer. This paper presents a fully intraocular and highly efficient wireless power transfer system, by introducing another inductive coupling link to bypass the trans-sclera trans-choroid cable. With the specific equivalent load of our customized 512-electrode stimulator, the current 3-coil inductive link was measured to have the overall power transfer efficiency around 36%, with 1-inch separation in saline. The high efficiency will favorably reduce the heat dissipation and electromagnetic field exposure to surrounding human tissues. The effect of the eyeball rotation on the power transfer efficiency was investigated as well. The efficiency can still maintain 14.7% with left and right deflection of 30 degree during normal use. The surgical procedure for the coils' implantation into the porcine eye was also demonstrated.

  7. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    López Terrones, Marcos Alonso, E-mail: malt.marcos@gmail.com [Ingeniería Biomédica, Dirección de Planeación, Servicios de Salud de Durango. Cuauhtémoc 225 Norte, Durango, Durango 34000 (Mexico); Solís-Nájera, Sergio Enrique, E-mail: solisnajera@ciencias.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, México, DF 04510 (Mexico)

    2014-11-07

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  8. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Science.gov (United States)

    López Terrones, Marcos Alonso; Solís-Nájera, Sergio Enrique

    2014-11-01

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  9. Mosquito coil emissions and health implications.

    Science.gov (United States)

    Liu, Weili; Zhang, Junfeng; Hashim, Jamal H; Jalaludin, Juliana; Hashim, Zailina; Goldstein, Bernard D

    2003-09-01

    Burning mosquito coils indoors generates smoke that can control mosquitoes effectively. This practice is currently used in numerous households in Asia, Africa, and South America. However, the smoke may contain pollutants of health concern. We conducted the present study to characterize the emissions from four common brands of mosquito coils from China and two common brands from Malaysia. We used mass balance equations to determine emission rates of fine particles (particulate matter pollutant concentrations resulting from burning mosquito coils could substantially exceed health-based air quality standards or guidelines. Under the same combustion conditions, the tested Malaysian mosquito coils generated more measured pollutants than did the tested Chinese mosquito coils. We also identified a large suite of volatile organic compounds, including carcinogens and suspected carcinogens, in the coil smoke. In a set of experiments conducted in a room, we examined the size distribution of particulate matter contained in the coil smoke and found that the particles were ultrafine and fine. The findings from the present study suggest that exposure to the smoke of mosquito coils similar to the tested ones can pose significant acute and chronic health risks. For example, burning one mosquito coil would release the same amount of PM(2.5) mass as burning 75-137 cigarettes. The emission of formaldehyde from burning one coil can be as high as that released from burning 51 cigarettes.

  10. The vestibulo-ocular reflex of the squirrel monkey during eccentric rotation and roll tilt

    Science.gov (United States)

    Merfeld, D. M.; Young, L. R.

    1995-01-01

    The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in six male squirrel monkeys during eccentric rotation. Monkeys were rotated in the dark at a constant velocity of 200 degrees/s (centrally or 79 cm off axis) with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's orientation (facing-motion or back-to-motion) had a dramatic influence on the VOR. These experiments show that: (a) the axis of eye rotation always shifted toward alignment with gravito-inertial force; (b) the peak value of horizontal slow phase eye velocity was greater with the monkey facing-motion than with back-to-motion; and (c) the time constant of horizontal eye movement decay was smaller with the monkey facing-motion than with back-to-motion. All of these findings were statistically significant and consistent across monkeys. In another set of tests, the same monkeys were rapidly tilted about their naso-occipital (roll) axis. Tilted orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the angular rotation, no consistent eye velocity response was observed during or following the tilt for any of the six monkeys. The absence of any eye movement response following tilt weighs against the possibility that translational linear VOR responses are due to simple high-pass filtering of the otolith signals. The VOR response during eccentric rotation was divided into the more familiar angular VOR and linear VOR components. The angular component is known to depend upon semicircular canal dynamics and central influences. The linear component of the response decays rapidly with a mean duration of only 6.6 s, while the axis of eye rotation rapidly aligns (< 10 s) with gravito-inertial force. These

  11. Design of modular coils for a quasi-axisymmetric stellarator with a flexible control of the magnetic field configuration

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, A.; Okamura, S.; Isobe, M.; Suzuki, C.; Nishimura, S.; Watari, T.; Matsuoka, K.

    2002-08-01

    A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform crosses the low-order rational value resulting in magnetic islands, the residues of islands are evaluated with which a further improvement of coil design can be made to eliminate magnetic islands. (author)

  12. Simulated Stellarator Edge Behavior with Modified HSX Coils

    Science.gov (United States)

    Bader, A.; Stephey, L. A.; Anderson, D. T.; Feng, Y.; Hegna, C. C.; Schmitz, O.; Talmadge, J. N.

    2014-10-01

    Predicting the edge behavior of a 3D device is a difficult but necessary requirement in the design of new fusion devices. In this poster we focus on prototypical stellarators generated through modifications to the HSX coils. We employ both helical coils to change the island size without altering the rotational transform, and divertor dipole coils to alter the internal structure of the islands. To determine the edge behavior of the designs we use simple metrics obtained through vacuum field-line following along with advanced simulation capabilities from the coupled codes EMC3-EIRENE. We show that strike point locations and concentrations can be altered with substantial changes to edge island sizes. Changes to the internal structure of the islands, producing alterations to flow structures and plasma density, but do not have a significant impact on strike point calculations or predicted heat flux. Results have implications on the role of islands in edges of stellarators and other 3D devices. Work supported by DOE-SC0006103.

  13. The coiled coils of cohesin are conserved in animals, but not in yeast.

    Directory of Open Access Journals (Sweden)

    Glenn E White

    Full Text Available BACKGROUND: The SMC proteins are involved in DNA repair, chromosome condensation, and sister chromatid cohesion throughout Eukaryota. Long, anti-parallel coiled coils are a prominent feature of SMC proteins, and are thought to serve as spacer rods to provide an elongated structure and to separate domains. We reported recently that the coiled coils of mammalian condensin (SMC2/4 showed moderate sequence divergence (approximately 10-15% consistent with their functioning as spacer rods. The coiled coils of mammalian cohesins (SMC1/3, however, were very highly constrained, with amino acid sequence divergence typically <0.5%. These coiled coils are among the most highly conserved mammalian proteins, suggesting that they make extensive contacts over their entire surface. METHODOLOGY/PRINCIPAL FINDINGS: Here, we broaden our initial analysis of condensin and cohesin to include additional vertebrate and invertebrate organisms and multiple species of yeast. We found that the coiled coils of SMC1/3 are highly constrained in Drosophila and other insects, and more generally across all animal species. However, in yeast they are no more constrained than the coils of SMC2/4 and Ndc80/Nuf2p, suggesting that they are serving primarily as spacer rods. CONCLUSIONS/SIGNIFICANCE: SMC1/3 functions for sister chromatid cohesion in all species. Since its coiled coils apparently serve only as spacer rods in yeast, it is likely that this is sufficient for sister chromatid cohesion in all species. This suggests an additional function in animals that constrains the sequence of the coiled coils. Several recent studies have demonstrated that cohesin has a role in gene expression in post-mitotic neurons of Drosophila, and other animal cells. Some variants of human Cornelia de Lange Syndrome involve mutations in human SMC1/3. We suggest that the role of cohesin in gene expression may involve intimate contact of the coiled coils of SMC1/3, and impose the constraint on sequence

  14. Optimum coil insertion speed of various coils in brain aneurysm embolization in vitro.

    Science.gov (United States)

    Konishi, Yoshifumi; Takeuchi, Masataka; Fukasaku, Kazuaki

    2016-10-01

    A coil must comprise material with shape memory to perform optimal coil embolization. To achieve this, the alloy characteristics of the coil (hardness, shape, and thickness) must be understood. In this experiment, a catheter was fixed in the bright position and the movement of the coil was observed under a constant rate of insertion; the optimal insertion rate during clinical use was investigated. The first coil insertion speed was evaluated using simulated aneurysms in an in vivo arterial model. The results showed that the insertion force relates to the deployment shape of the coil, that the feedback through the force indicator using sound is very effective, and that the recorder is useful for analysis of coil embolization. The inserted coils during aneurysm embolization were able to wind uniformly within the aneurysm due to a variety of factors (guiding or micro-catheter position and kick-back phenomenon such as delivery wire). Optimal speed is achieved with proper coil design, which allows the coil to be inserted into the aneurysm. The shape and size of the aneurysm can help determine the necessary size and design of the coil that should be used during the optimal speed range. Aneurysm wall and coil characteristics are considered, along with the friction state of the coil (hardness, shape, and thickness), leading to improvements in safety during the insertion procedure at optimum speed.

  15. Unusually Stable Helical Coil Allotrope of Phosphorus.

    Science.gov (United States)

    Liu, Dan; Guan, Jie; Jiang, Jingwei; Tománek, David

    2016-12-14

    We have identified an unusually stable helical coil allotrope of phosphorus. Our ab initio density functional theory calculations indicate that the uncoiled, isolated straight one-dimensional chain is equally stable as a monolayer of black phosphorus dubbed phosphorene. The coiling tendency and the attraction between adjacent coil segments add an extra stabilization energy of ∼12 meV/atom to the coil allotrope, similar in value to the ∼16 meV/atom interlayer attraction in bulk black phosphorus. Thus, the helical coil structure is essentially as stable as black phosphorus, the most stable phosphorus allotrope known to date. With an optimum radius of 2.4 nm, the helical coil of phosphorus may fit well and even form inside wide carbon nanotubes.

  16. The Golgin Family of Coiled-Coil Tethering Proteins

    Directory of Open Access Journals (Sweden)

    Tomasz M Witkos

    2016-01-01

    Full Text Available The golgins are a family of predominantly coiled-coil proteins that are localized to the Golgi apparatus. Golgins are present in all eukaryotes, suggesting an evolutionary conserved function. Golgins are anchored to the Golgi membrane by their carboxy terminus and are predicted to adopt an extended conformation that projects into the surrounding cytoplasm. This arrangement is ideal for the capture or tethering of nearby membranes or cytoskeletal elements. Golgin-mediated tethering is thought to be important for vesicular traffic at the Golgi apparatus, the maintenance of Golgi architecture, as well as the positioning of the Golgi apparatus within cells. In addition to acting as tethers, some golgins can also sequester various factors at the Golgi membrane, allowing for the spatiotemporal regulation of downstream cellular functions. Although it is now established that golgins are membrane and cytoskeleton tethers, the mechanisms underlying tethering remain poorly defined. Moreover, the importance of golgin-mediated tethering in a physiological context remains to be fully explored. This review will describe our current understanding of golgin function, highlighting recent progress that has been made, and goes on to discuss outstanding questions and potential avenues for future research with regard to this family of conserved Golgi-associated proteins.

  17. Force modulated conductance of artificial coiled-coil protein monolayers.

    Science.gov (United States)

    Atanassov, Alexander; Hendler, Ziv; Berkovich, Inbal; Ashkenasy, Gonen; Ashkenasy, Nurit

    2013-01-01

    Studies of charge transport through proteins bridged between two electrodes have been the subject of intense research in recent years. However, the complex structure of proteins makes it difficult to elucidate transport mechanisms, and the use of simple peptide oligomers may be an over simplified model of the proteins. To bridge this structural gap, we present here studies of charge transport through artificial parallel coiled-coil proteins conducted in dry environment. Protein monolayers uniaxially oriented at an angle of ∼ 30° with respect to the surface normal were prepared. Current voltage measurements, obtained using conductive-probe atomic force microscopy, revealed the mechano-electronic behavior of the protein films. It was found that the low voltage conductance of the protein monolayer increases linearly with applied force, mainly due to increase in the tip contact area. Negligible compression of the films for loads below 26 nN allowed estimating a tunneling attenuation factor, β(0) , of 0.5-0.6 Å(-1) , which is akin to charge transfer by tunneling mechanism, despite the comparably large charge transport distance. These studies show that mechano-electronic behavior of proteins can shed light on their complex charge transport mechanisms, and on how these mechanisms depend on the detailed structure of the proteins. Such studies may provide insightful information on charge transfer in biological systems.

  18. Vibration control using a variable coil-based friction damper

    Science.gov (United States)

    Amjadian, Mohsen; Agrawal, Anil K.

    2017-04-01

    This paper is focused on the analytical model, design, and simulation of a variable coil-based friction damper (VCBFD) for vibration control of structures. The proposed VCBFD is composed of a soft ferromagnetic plate, made of a linear magnetic material, and two identical thick rectangular air-core coils connected in parallel, each one attached to the plate through a friction pad. The friction force is provided by a normal force produced through an attractive electromagnetic interaction between the air-core coils (ACs) and the soft ferromagnetic plate when sliding relative to each other. The magnitude of the normal force in the damper is varied by a semi-active controller that controls the command current passing through the ACs. To demonstrate the efficiency of the proposed VCBFD and its semi-active controller, it has been implemented on a two-degree-of-freedom (2DOF) base-isolated model subjected to the acceleration components of three records of strong earthquakes. The results show that the performance of the proposed VCBFD in its passive-on mode is overshadowed by the undesirable effects of stick-slip motion. However, the damper in its semi-active mode is more successful in not only reducing the displacement of the base-floor but also avoiding stick-slip motion, due to acting completely in its sliding phase.

  19. An Experimental Study on Constraint Cooling Process of Hot-rolled CoilS

    Institute of Scientific and Technical Information of China (English)

    Lijuan WANG; Chunli ZHANG

    2003-01-01

    In order to master mechanical property, surface quality and microstructure of constraint cooling (CC) coils undervarious water cooling parameters, more than 100 coils cooling experiments were done with real production process,of which is designed a coolin

  20. Transport vesicle tethering at the trans Golgi network: coiled coil proteins in action

    Directory of Open Access Journals (Sweden)

    Pak-yan Patricia Cheung

    2016-03-01

    Full Text Available The Golgi complex is decorated with so-called Golgin proteins that share a common feature: a large proportion of their amino acid sequences are predicted to form coiled-coil structures. The possible presence of extensive coiled coils implies that these proteins are highly elongated molecules that can extend a significant distance from the Golgi surface. This property would help them to capture or trap inbound transport vesicles and to tether Golgi mini-stacks together. This review will summarize our current understanding of coiled coil tethers that are needed for the receipt of transport vesicles at the trans Golgi network. How do long tethering proteins actually catch vesicles? Golgi-associated, coiled coil tethers contain numerous binding sites for small GTPases, SNARE proteins, and vesicle coat proteins. How are these interactions coordinated and are any or all of them important for the tethering process? Progress towards understanding these questions and remaining, unresolved mysteries will be discussed.

  1. A high-sensitive static vector magnetometer based on two vibrating coils.

    Science.gov (United States)

    Yin, Jing; Pan, Cheng Liang; Wang, Hong Bo; Feng, Zhi Hua

    2011-12-01

    A static vector magnetometer based on two-dimensional (2D) vibrating coils actuated by a piezoelectric cantilever is presented. Two individual sensing coils are orthogonally fastened at the tip of cantilever and piezoelectric sheets are used to excite the cantilever bending. Due to off-axis coupler on the tip, the cantilever generates bending and twisting vibrations simultaneously on their corresponding resonant frequencies, realizing the 2D rotating vibrations of the coils. According to Faraday-Lenz Law, output voltages are induced from the coils. They are amplified by a pre-amplifier circuit, decoupled by a phase-sensitive detector, and finally used to calculate the vector of magnetic field at the coil location. The coil head of a prototype magnetometer possesses a dc sensitivity of around 10 μV/Gs with a good linearity in the measuring range from 0 to 16 μT. The corresponding noise level is about 13.1 nT in the bandwidth from 0.01 Hz to 1 Hz.

  2. Superconducting Coil of Po Dipole

    CERN Multimedia

    1983-01-01

    The Po superconducting dipole was built as a prototype beam transport magnet for the SPS extracted proton beam P0. Its main features were: coil aperture 72 mm, length 5 m, room-temperature yoke, NbTi cable conductor impregnated with solder, nominal field 4.2 T at 4.7 K (87% of critical field). It reached its nominal field without any quench.After this successful test up to its nominal field of 4.2 T, the power was not raised to reach a quench. The magnet was not installed in a beam and had no other further use. Nevertheless its construction provided knowledges and experience which became useful in the design and construction of the LHC magnets. The photo shows a detail of the inner layer winding before superposing the outer layer to form the complete coil of a pole. Worth noticing is the interleaved glass-epoxy sheet (white) with grooved channels for the flow of cooling helium. See also 8211532X.

  3. Multicoil2: predicting coiled coils and their oligomerization states from sequence in the twilight zone.

    Directory of Open Access Journals (Sweden)

    Jason Trigg

    Full Text Available The alpha-helical coiled coil can adopt a variety of topologies, among the most common of which are parallel and antiparallel dimers and trimers. We present Multicoil2, an algorithm that predicts both the location and oligomerization state (two versus three helices of coiled coils in protein sequences. Multicoil2 combines the pairwise correlations of the previous Multicoil method with the flexibility of Hidden Markov Models (HMMs in a Markov Random Field (MRF. The resulting algorithm integrates sequence features, including pairwise interactions, through multinomial logistic regression to devise an optimized scoring function for distinguishing dimer, trimer and non-coiled-coil oligomerization states; this scoring function is used to produce Markov Random Field potentials that incorporate pairwise correlations localized in sequence. Multicoil2 significantly improves both coiled-coil detection and dimer versus trimer state prediction over the original Multicoil algorithm retrained on a newly-constructed database of coiled-coil sequences. The new database, comprised of 2,105 sequences containing 124,088 residues, includes reliable structural annotations based on experimental data in the literature. Notably, the enhanced performance of Multicoil2 is evident when tested in stringent leave-family-out cross-validation on the new database, reflecting expected performance on challenging new prediction targets that have minimal sequence similarity to known coiled-coil families. The Multicoil2 program and training database are available for download from http://multicoil2.csail.mit.edu.

  4. Accommodation of structural rearrangements in the huntingtin-interacting protein 1 coiled-coil domain

    Energy Technology Data Exchange (ETDEWEB)

    Wilbur, Jeremy D., E-mail: jwilbur@msg.ucsf.edu [Graduate Program in Biophysics, University of California, San Francisco, California 94143 (United States); Hwang, Peter K. [Department of Biochemistry and Biophysics, University of California, San Francisco, California 94143 (United States); Brodsky, Frances M. [The G. W. Hooper Foundation, Departments of Microbiology and Immunology and of Bioengineering and Therapeutic Sciences, University of California, San Francisco, California 94143 (United States); Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143 (United States); Fletterick, Robert J. [Department of Biochemistry and Biophysics, University of California, San Francisco, California 94143 (United States); Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143 (United States); Graduate Program in Biophysics, University of California, San Francisco, California 94143 (United States)

    2010-03-01

    Variable packing interaction related to the conformational flexibility within the huntingtin-interacting protein 1 coiled coil domain. Huntingtin-interacting protein 1 (HIP1) is an important link between the actin cytoskeleton and clathrin-mediated endocytosis machinery. HIP1 has also been implicated in the pathogenesis of Huntington’s disease. The binding of HIP1 to actin is regulated through an interaction with clathrin light chain. Clathrin light chain binds to a flexible coiled-coil domain in HIP1 and induces a compact state that is refractory to actin binding. To understand the mechanism of this conformational regulation, a high-resolution crystal structure of a stable fragment from the HIP1 coiled-coil domain was determined. The flexibility of the HIP1 coiled-coil region was evident from its variation from a previously determined structure of a similar region. A hydrogen-bond network and changes in coiled-coil monomer interaction suggest that the HIP1 coiled-coil domain is uniquely suited to allow conformational flexibility.

  5. Some aspects of the design of the ITER NBI Active Correction and Compensation Coils

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Javier, E-mail: javier.alonso@ciemat.es [CIEMAT, Laboratorio Nacional de Fusión, Avda. Complutense 40, 28040 Madrid (Spain); Barrera, Germán; Cabrera, Santiago; Rincón, Esther; Ríos, Luis; Soleto, Alfonso [CIEMAT, Laboratorio Nacional de Fusión, Avda. Complutense 40, 28040 Madrid (Spain); El-Ouazzani, Anass; Graceffa, Joseph; Shah, Darshan; Urbani, Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Agarici, Gilbert [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3 – 07/08, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • Water cooled coil design. • Magnetic shielding of the plasma heating Neutral Beam Injection System. • Active coils for magnetic field compensation. - Abstract: The neutral beam system for ITER consists of two heating and current drive injectors plus a diagnostic neutral beam injector. The proposed physical plant layout allows for a possible third heating injector to be installed later. For correct operation of the beam source, and to avoid deflections of the charged fraction of the beam, the magnetic field along the beam path must be very low. To minimize the stray ITER field in critical areas (ion source, acceleration grids, neutralizer, residual ion dump), a Magnetic Field Reduction System will envelop the beam vessels and the high voltage transmission lines to ion source. This whole system comprises the Passive Magnetic Shield, a set of thick steel plates, and the Active Correction and Compensation Coils, a set of coils carrying currents which depend on the tokamak stray field. This paper describes the status of the coil design, terminals and support structures, as well as a description of the calculations carried out. Most coils are suitable for removal from their final position to be replaced in case of a fault. Conclusions of the chosen design highlight the strategy for the system feasibility.

  6. Test of Optimized 120-mm LARP $Nb_{3}S_n$ Quadrupole Coil Using Magnetic Mirror Structure

    CERN Document Server

    Chlachidze, G; Andreev, N; Anerella, M; Barzi, E; Bossert, R; Caspi, S; Cheng, D; Dietderich, D; Felice, H; Ferracin, P; Ghosh, A; Godeke, A; Hafalia, A R; Kashikhin, V V; Lamm, M; Marchevsky, M; Nobrega, A; Novitski, I; Orris, D; Sabbi, G L; Schmalzle, J; Wanderer, P; Zlobin, A V

    2013-01-01

    The US LHC accelerator research program (LARP) is developing a new generation of large - aperture high - field quadrupoles based on Nb 3 Sn conductor for the High luminosity upgrade of Large Hadron Collider (HiLumi - LHC). Tests of the first series of 120 - mm aperture HQ coils revealed the necessity for further optimization of the coil design and fabrication process. Modifications in coil design were gradually implemented in two HQ coils previously tested at Fermi National Accelerato r Laboratory (Fermilab) using a magnetic mirror structure (HQM01 and HQM02). This paper describes the construction and test of an HQ mirror model with a coil of optimized design and with an interlayer resistive core in the conductor. The cable for this co il was made of a smaller diameter strand, providing more room for coil expansion during reaction. The 0.8 - mm strand, used in all previous HQ coils was replaced with a 0.778 - mm Nb 3 Sn strand of RRP 108/127 sub - element design. The coil was instrumented with voltage taps, h...

  7. Transport of one SC coil through the village of Meyrin

    CERN Multimedia

    1956-01-01

    In 1952, before CERN was officially founded, two accelerator projects were launched: one for an innovative accelerator to operate at an energy level unequalled at the time, the other for a more standard machine, a Synchro-Cyclotron (SC) to operate at 600 MeV. Design work on the SC was started in 1952 and carried out by teams scattered throughout Europe. Once construction began in 1954, CERN had to arrange road transport for the first of what has since been a long series of spectacular component deliveries, such as those of the machine's two magnetic coils each weighing 60 tonnes and measuring 7.2 metres in diameter. Above, one of them is seen passing through the village of Meyrin. The SC was commissioned in 1957 and was operational for 34 years!

  8. A study of the electromagnetic characteristics of no-insulation GdBCO racetrack coils under an external magnetic ripple field

    Science.gov (United States)

    Choi, Y. H.; Yang, D. G.; Kim, Y. G.; Kim, S. G.; Song, J. B.; Lee, H. G.

    2016-04-01

    Here we report the effect of an external magnetic ripple field on the electromagnetic characteristics of GdBCO racetrack coils being operated with a constant DC current. Two types of GdBCO racetrack coils, one wound without turn-to-turn insulation (NI) and the other wound with Kapton tape (INS), were examined under external ripple fields generated by a permanent magnet mounted on a rotor, which was driven by a separate AC motor. The voltage fluctuations and magnetic field variations were measured with respect to the external ripple field intensity (B ERF), rotating speed, and the operating condition. When the INS and NI coils were exposed to an external ripple field (herein, I op = 80 A, B ERF = 2 mT, and 5 rpm), a voltage fluctuation occurred because a time-varying magnetic field interacted with an electric circuit creating an electromotive force. The peak-to-peak voltage (V pp = 0.29 mV) of the NI coil was ∼1.86 times lower than that (0.54 mV) of the INS coil, because the voltage response of the NI coil lagged behind dB/dt due to the existence of turn-to-turn contact. Furthermore, the V pp of the INS coil increased with increasing B ERF and rotating speed, while those of the NI coil were barely affected due to the delay of electromagnetic induction. In excessive current and ripple field conditions (I op = 1.125 I c, B ERF = 8 mT, and 50 rpm) the INS coil eventually quenched while the NI coil did not, implying that the electromagnetic stability of the NI coil in excessive time-varying field conditions was superior to that of the INS coil.

  9. An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

    Science.gov (United States)

    Brown, G. V.; Dirusso, E.; Provenza, A. J.

    1995-01-01

    A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

  10. Beam Loss Calibration Studies for High Energy Proton Accelerators

    CERN Document Server

    Stockner, M

    2007-01-01

    CERN's Large Hadron Collider (LHC) is a proton collider with injection energy of 450 GeV and collision energy of 7 TeV. Superconducting magnets keep the particles circulating in two counter rotating beams, which cross each other at the Interaction Points (IP). Those complex magnets have been designed to contain both beams in one yoke within a cryostat. An unprecedented amount of energy will be stored in the circulating beams and in the magnet system. The LHC outperforms other existing accelerators in its maximum beam energy by a factor of 7 and in its beam intensity by a factor of 23. Even a loss of a small fraction of the beam particles may cause the transition from the superconducting to the normal conducting state of the coil or cause physical damage to machine components. The unique combination of these extreme beam parameters and the highly advanced superconducting technology has the consequence that the LHC needs a more efficient beam cleaning and beam loss measurement system than previous accelerators....

  11. Beam Loss Calibration Studies for High Energy Proton Accelerators

    CERN Document Server

    Stockner, M

    2007-01-01

    CERN's Large Hadron Collider (LHC) is a proton collider with injection energy of 450 GeV and collision energy of 7 TeV. Superconducting magnets keep the particles circulating in two counter rotating beams, which cross each other at the Interaction Points (IP). Those complex magnets have been designed to contain both beams in one yoke within a cryostat. An unprecedented amount of energy will be stored in the circulating beams and in the magnet system. The LHC outperforms other existing accelerators in its maximum beam energy by a factor of 7 and in its beam intensity by a factor of 23. Even a loss of a small fraction of the beam particles may cause the transition from the superconducting to the normal conducting state of the coil or cause physical damage to machine components. The unique combination of these extreme beam parameters and the highly advanced superconducting technology has the consequence that the LHC needs a more efficient beam cleaning and beam loss measurement system than previous accelerators....

  12. Rotating flow

    CERN Document Server

    Childs, Peter R N

    2010-01-01

    Rotating flow is critically important across a wide range of scientific, engineering and product applications, providing design and modeling capability for diverse products such as jet engines, pumps and vacuum cleaners, as well as geophysical flows. Developed over the course of 20 years' research into rotating fluids and associated heat transfer at the University of Sussex Thermo-Fluid Mechanics Research Centre (TFMRC), Rotating Flow is an indispensable reference and resource for all those working within the gas turbine and rotating machinery industries. Traditional fluid and flow dynamics

  13. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  14. Development and coil fabrication for the LARP 3.7-m long Nb3Sn quadruple

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, G.; Andreev, N.; Anerella, M.; Barzi, E.; Bossert, R.; Caspi, S.; Chlachidize, G.; Dietderich, D.; Felice, H.; Ferracin, P.; Ghosh, A.; /Fermilab /Brookhaven /LBL, Berkeley /Texas A-M

    2009-02-01

    The U.S. LHC Accelerator Research Program (LARP) has started the fabrication of 3.7-m long Nb{sub 3}Sn quadrupole models. The Long Quadrupoles (LQ) are 'Proof-of-Principle' magnets which are to demonstrate that Nb3Sn technology is mature for use in high energy particle accelerators. Their design is based on the LARP Technological Quadrupole (TQ) models, developed at FNAL and LBNL, which have design gradients higher than 200 T/m and an aperture of 90 mm. The plans for the LQ R&D and a design update are presented and discussed in this paper. The challenges of fabricating long accelerator-quality Nb{sub 3}Sn coils are presented together with the solutions adopted for the LQ coils (based on the TQ experience). During the fabrication and inspection of practice coils some problems were found and corrected. The fabrication at BNL and FNAL of the set of coils for the first Long Quadrupole is in progress.

  15. Development and Coil Fabrication for the LARP 3.7-m Long Nb3Sn Quadrupole

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, G.; Andreev, N.; Anerella, M.; Barzi, E.; Bossert, R.; Caspi, S.; Chlachidize, G.; Dietderich, D.; Felice, H.; Ferracin, P.; Ghosh, A.; Hafalia, R.; Hannaford, R.; Jochen, G.; Kashikhin, V.V.; Kovach, P.; Lamm, M.; Lietzke, A.; McInturff, A.; Muratore,, J.; Nobreaga, F.; Novitsky, I.; Peggs, S.; Prestemon, S.; Sabbi, G. L.; Schmalzle, J.; Turrioni, D.; Wanderer, P.; Whitson, G.; Zlobin, A. V.

    2008-08-17

    The U.S. LHC Accelerator Research Program (LARP) has started the fabrication of 3.7-m long Nb{sub 3}Sn quadrupole models. The Long Quadrupoles (LQ) are 'Proof-of-Principle' magnets which are to demonstrate that Nb{sub 3}Sn technology is mature for use in high energy particle accelerators. Their design is based on the LARP Technological Quadrupole (TQ) models, developed at FNAL and LBNL, which have design gradients higher than 200 T/m and an aperture of 90 mm. The plans for the LQ R&D and a design update are presented and discussed in this paper. The challenges of fabricating long accelerator-quality Nb{sub 3}Sn coils are presented together with the solutions adopted for the LQ coils (based on the TQ experience). During the fabrication and inspection of practice coils some problems were found and corrected. The fabrication at BNL and FNAL of the set of coils for the first Long Quadrupole is in progress.

  16. Design, Construction and Test of Cryogen-Free HTS Coil Structure

    Energy Technology Data Exchange (ETDEWEB)

    Hocker, H.; Anerella, M.; Gupta, R.; Plate, S.; Sampson, W.; Schmalzle, J.; Shiroyanagi, Y.

    2011-03-28

    This paper will describe design, construction and test results of a cryo-mechanical structure to study coils made with the second generation High Temperature Superconductor (HTS) for the Facility for Rare Isotope Beams (FRIB). A magnet comprised of HTS coils mounted in a vacuum vessel and conduction-cooled with Gifford-McMahon cycle cryocoolers is used to develop and refine design and construction techniques. The study of these techniques and their effect on operations provides a better understanding of the use of cryogen free magnets in future accelerator projects. A cryogen-free, superconducting HTS magnet possesses certain operational advantages over cryogenically cooled, low temperature superconducting magnets.

  17. 49 CFR 236.730 - Coil, receiver.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Coil, receiver. 236.730 Section 236.730 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Coil, receiver. Concentric layers of insulated wire wound around the core of a receiver of an...

  18. Operator coil monitoring Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Erhart, M.F.

    1995-05-16

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring and control of the Programmable Logic Controller (PLC) abort coils from the Master and RSS stations will be systematically tested during performance of this procedure. It should be noted that these are not physical abort coils but software coils controlled by the software`s ladder logic. The readiness of the DACS to properly interface with the ENRAF wire level gauge installed in the SY-101 storage tank will also be tested. During this test, a verification of all abort coil indications will be conducted at the DACS Development Facility in the 306E Building by injecting an input signal for each DACS sensor that has an associated abort coil until the abort coil actuates, and then ensuring that the status of the abort coil indicated at the Master and RSS stations is correct. Each abort coil will also be tested to ensure that the ``ENABLE`` and ``DISABLE`` controls from the Master and RSS stations function correctly, and only with the use of proper passwords.

  19. Evidence-based pathology: umbilical cord coiling.

    Science.gov (United States)

    Khong, T Y

    2010-12-01

    The generation of a pathology test result must be based on criteria that are proven to be acceptably reproducible and clinically relevant to be evidence-based. This review de-constructs the umbilical cord coiling index to illustrate how it can stray from being evidence-based. Publications related to umbilical cord coiling were retrieved and analysed with regard to how the umbilical coiling index was calculated, abnormal coiling was defined and reference ranges were constructed. Errors and other influences that can occur with the measurement of the length of the umbilical cord or of the number of coils can compromise the generation of the coiling index. Definitions of abnormal coiling are not consistent in the literature. Reference ranges defining hypocoiling or hypercoiling have not taken those potential errors or the possible effect of gestational age into account. Even the way numerical test results in anatomical pathology are generated, as illustrated by the umbilical coiling index, warrants a critical analysis into its evidence base to ensure that they are reproducible or free from errors.

  20. Coil Optimization for High Temperature Superconductor Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech

    2011-01-01

    This paper presents topology optimization of HTS racetrack coils for large HTS synchronous machines. The topology optimization is used to acquire optimal coil designs for the excitation system of 3 T HTS machines. Several tapes are evaluated and the optimization results are discussed. The optimiz...

  1. Functional investigation of the plant-specific long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC and PICC-LIKE (PICL in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Sowmya Venkatakrishnan

    Full Text Available We have identified and characterized two Arabidopsis long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC and PICC-LIKE (PICL. PICC (147 kDa and PICL (87 kDa are paralogs that consist predominantly of a long coiled-coil domain (expanded in PICC, with a predicted transmembrane domain at the immediate C-terminus. Orthologs of PICC and PICL were found exclusively in vascular plants. PICC and PICL GFP fusion proteins are anchored to the cytoplasmic surface of the endoplasmic reticulum (ER membrane by a C-terminal transmembrane domain and a short tail domain, via a tail-anchoring mechanism. T-DNA-insertion mutants of PICC and PICL as well as the double mutant show an increased sensitivity to the plant abiotic stress hormone abscisic acid (ABA in a post-germination growth response. PICC, but not PICL gene expression is induced by the bacterial pathogen-associated molecular pattern (PAMP flg22. T-DNA insertion alleles of PICC, but not PICL, show increased susceptibility to the non-virulent strain P. syringae pv. tomato DC3000 hrcC, but not to the virulent strain P. syringae pv. tomato DC3000. This suggests that PICC mutants are compromised in PAMP-triggered immunity (PTI. The data presented here provide first evidence for the involvement of a plant long coiled-coil protein in a plant defense response.

  2. Magnetic Fields at the Center of Coils

    Science.gov (United States)

    Binder, Philippe; Hui, Kaleonui; Goldman, Jesse

    2014-01-01

    In this note we synthesize and extend expressions for the magnetic field at the center of very short and very long current-carrying coils. Elementary physics textbooks present the following equation for the magnetic field inside a very long current-carrying coil (solenoid): B[subscript sol] = µ[subscript 0] (N/L) I, (1) where I is the current, N…

  3. NMR local coil with adjustable spacing

    Energy Technology Data Exchange (ETDEWEB)

    Dembinski, G.T.

    1988-03-22

    A local coil assembly for use in NMR imaging is described which comprises: a base; a first local coil module mounted to the base and extending upward therefrom; sockets disposed in the base, each at a different distance from the first local coil module; a second local coil module having a connector therein which mates with each of the sockets to enable the second local coil module to be connected to the base at any one of the sockets; and a set of reactive components. The values of the respective reactive components are selected such that the second local oil module may be connected to any of the sockets without any substantial change in the resonant frequency of the assembly.

  4. A study on geometry effect of transmission coil for micro size magnetic induction coil

    Science.gov (United States)

    Lee, Kyung Hwa; Jun, Byoung Ok; Kim, Seunguk; Lee, Gwang Jun; Ryu, Mingyu; Choi, Ji-Woong; Jang, Jae Eun

    2016-05-01

    The effects of transmission (Tx) coil structure have been studied for micro-size magnetic induction coil. The size of the receiving (Rx) coil should be shrunk to the micrometer level for the various new applications such as micro-robot and wireless body implanted devices. In case of the macro-scale magnetic induction coil, the power transmission efficiency is generally considered to be higher as the inductance of the transmission coil became larger; however, the large size difference between macro-size Tx coil and micro-size Rx coil can decrease the power transmission efficiency due to the difference of resonance frequency. Here, we study a correlation of the power transmission with the size and distance between the macro-size Tx and micro-size Rx coils using magnetic induction technique. The maximum power efficiency was 0.28/0.23/0.13/0.12% at the distance of 0.3/1/3/5 cm between Rx and Tx coil. In addition, more efficient wireless power transferring method is suggested with a floating coil for the body implantable devices. The voltage output increased up to 5.4 mV than the original one Tx coil system. The results demonstrated the foundational wireless power transferring system with enhanced power efficiency.

  5. Detection of alpha-helical coiled-coil dimer formation by spin-labeled synthetic peptides: a model parallel coiled-coil peptide and the antiparallel coiled coil formed by a replica of the ProP C-terminus.

    Science.gov (United States)

    Hillar, Alexander; Tripet, Brian; Zoetewey, David; Wood, Janet M; Hodges, Robert S; Boggs, Joan M

    2003-12-30

    Electron paramagnetic resonance spectroscopy was used to determine relative peptide orientation within homodimeric, alpha-helical coiled-coil structures. Introduction of cysteine (Cys) residues into peptides/proteins for spin labeling allows detection of their oligomerization from exchange broadening or dipolar interactions between residues within 25 A of each other. Two synthetic peptides containing Cys substitutions were used: a 35-residue model peptide and the 30-residue ProP peptide. The model peptide is known to form a stable, parallel homodimeric coiled coil, which is partially destabilized by Cys substitutions at heptad a and d positions (peptides C30a and C33d). The ProP peptide, a 30-residue synthetic peptide, corresponds to residues 468-497 of osmoregulatory transporter ProP from Escherichia coli. It forms a relatively unstable, homodimeric coiled coil that is predicted to be antiparallel in orientation. Cys was introduced in heptad g positions of the ProP peptide, near the N-terminus (K473C, creating peptide C473g) or closer to the center of the sequence (E480C, creating peptide C480g). In contrast to the destabilizing effect of Cys substitution at the core heptad a or d positions of model peptides C30a and C33d, circular dichroism spectroscopy showed that Cys substitutions at the heptad g positions of the ProP peptide had little or no effect on coiled-coil stability. Thermal denaturation analysis showed that spin labeling increased the stability of the coiled coil for all peptides. Strong exchange broadening was detected for both C30a and C33d, in agreement with a parallel structure. EPR spectra of C480g had a large hyperfine splitting of about 90 G, indicative of strong dipole-dipole interactions and a distance between spin-labeled residues of less than 9 A. Spin-spin interactions were much weaker for C473g. These results supported the hypothesis that the ProP peptide primarily formed an antiparallel coiled coil, since formation of a parallel dimer

  6. Rotational Electromagnetic Energy Harvesting System

    Science.gov (United States)

    Dinulovic, Dragan; Brooks, Michael; Haug, Martin; Petrovic, Tomislav

    This paper presents development of the rotational electromagnetic energy harvesting transducer. The transducer is driven mechanically by pushing a button; therefore, the mechanical energy will be converted into electrical energy. The energy harvesting (EH) transducer consists of multilayer planar coils embedded in a PCB, multipolar NdFeB hard magnets, and a mechanical system for movement conversion. The EH transducer generate an energy of about 4 mJ at a load of 10 Ω. The maximum open circuit output voltage is as high as 2 V and the maximum short circuit output current is 800 mA.

  7. Rotating Wavepackets

    Science.gov (United States)

    Lekner, John

    2008-01-01

    Any free-particle wavepacket solution of Schrodinger's equation can be converted by differentiations to wavepackets rotating about the original direction of motion. The angular momentum component along the motion associated with this rotation is an integral multiple of [h-bar]. It is an "intrinsic" angular momentum: independent of origin and…

  8. Rotational elasticity

    Science.gov (United States)

    Vassiliev, Dmitri

    2017-04-01

    We consider an infinite three-dimensional elastic continuum whose material points experience no displacements, only rotations. This framework is a special case of the Cosserat theory of elasticity. Rotations of material points are described mathematically by attaching to each geometric point an orthonormal basis that gives a field of orthonormal bases called the coframe. As the dynamical variables (unknowns) of our theory, we choose the coframe and a density. We write down the general dynamic variational functional for our rotational theory of elasticity, assuming our material to be physically linear but the kinematic model geometrically nonlinear. Allowing geometric nonlinearity is natural when dealing with rotations because rotations in dimension three are inherently nonlinear (rotations about different axes do not commute) and because there is no reason to exclude from our study large rotations such as full turns. The main result of the talk is an explicit construction of a class of time-dependent solutions that we call plane wave solutions; these are travelling waves of rotations. The existence of such explicit closed-form solutions is a non-trivial fact given that our system of Euler-Lagrange equations is highly nonlinear. We also consider a special case of our rotational theory of elasticity which in the stationary setting (harmonic time dependence and arbitrary dependence on spatial coordinates) turns out to be equivalent to a pair of massless Dirac equations. The talk is based on the paper [1]. [1] C.G.Boehmer, R.J.Downes and D.Vassiliev, Rotational elasticity, Quarterly Journal of Mechanics and Applied Mathematics, 2011, vol. 64, p. 415-439. The paper is a heavily revised version of preprint https://arxiv.org/abs/1008.3833

  9. Future accelerators (?)

    Energy Technology Data Exchange (ETDEWEB)

    John Womersley

    2003-08-21

    I describe the future accelerator facilities that are currently foreseen for electroweak scale physics, neutrino physics, and nuclear structure. I will explore the physics justification for these machines, and suggest how the case for future accelerators can be made.

  10. Simultaneous formation of right- and left-handed anti-parallel coiled-coil interfaces by a coil2 fragment of human lamin A.

    Science.gov (United States)

    Kapinos, Larisa E; Burkhard, Peter; Herrmann, Harald; Aebi, Ueli; Strelkov, Sergei V

    2011-04-22

    The elementary building block of all intermediate filaments (IFs) is a dimer featuring a central α-helical rod domain flanked by the N- and C-terminal end domains. In nuclear IF proteins (lamins), the rod domain consists of two coiled-coil segments, coil1 and coil2, that are connected by a short non-helical linker. Coil1 and the C-terminal part of coil2 contain the two highly conserved IF consensus motifs involved in the longitudinal assembly of dimers. The previously solved crystal structure of a lamin A fragment (residues 305-387) corresponding to the second half of coil2 has yielded a parallel left-handed coiled coil. Here, we present the crystal structure and solution properties of another human lamin A fragment (residues 328-398), which is largely overlapping with fragment 305-387 but harbors a short segment of the tail domain. Unexpectedly, no parallel coiled coil forms within the crystal. Instead, the α-helices are arranged such that two anti-parallel coiled-coil interfaces are formed. The most significant interface has a right-handed geometry, which is accounted for by a characteristic 15-residue repeat pattern that overlays with the canonical heptad repeat pattern. The second interface is a left-handed anti-parallel coiled coil based on the predicted heptad repeat pattern. In solution, the fragment reveals only a weak dimerization propensity. We speculate that the C-terminus of coil2 might unzip, thereby allowing for a right-handed coiled-coil interface to form between two laterally aligned dimers. Such an interface might co-exist with a heterotetrameric left-handed coiled-coil assembly, which is expected to be responsible for the longitudinal A(CN) contact.

  11. N@a and N@d: Oligomer and Partner Specification by Asparagine in Coiled-Coil Interfaces.

    Science.gov (United States)

    Fletcher, Jordan M; Bartlett, Gail J; Boyle, Aimee L; Danon, Jonathan J; Rush, Laura E; Lupas, Andrei N; Woolfson, Derek N

    2017-02-17

    The α-helical coiled coil is one of the best-studied protein-protein interaction motifs. As a result, sequence-to-structure relationships are available for the prediction of natural coiled-coil sequences and the de novo design of new ones. However, coiled coils adopt a wide range of oligomeric states and topologies, and our understanding of the specification of these and the discrimination between them remains incomplete. Gaps in our knowledge assume more importance as coiled coils are used increasingly to construct biomimetic systems of higher complexity; for this, coiled-coil components need to be robust, orthogonal, and transferable between contexts. Here, we explore how the polar side chain asparagine (Asn, N) is tolerated within otherwise hydrophobic helix-helix interfaces of coiled coils. The long-held view is that Asn placed at certain sites of the coiled-coil sequence repeat selects one oligomer state over others, which is rationalized by the ability of the side chain to make hydrogen bonds, or interactions with chelated ions within the coiled-coil interior of the favored state. We test this with experiments on de novo peptide sequences traditionally considered as directing parallel dimers and trimers, and more widely through bioinformatics analysis of natural coiled-coil sequences and structures. We find that when located centrally, rather than near the termini of such coiled-coil sequences, Asn does exert the anticipated oligomer-specifying influence. However, outside of these bounds, Asn is observed less frequently in the natural sequences, and the synthetic peptides are hyperthermostable and lose oligomer-state specificity. These findings highlight that not all regions of coiled-coil repeat sequences are equivalent, and that care is needed when designing coiled-coil interfaces.

  12. Spaced-based search coil magnetometers

    Science.gov (United States)

    Hospodarsky, George B.

    2016-12-01

    Search coil magnetometers are one of the primary tools used to study the magnetic component of low-frequency electromagnetic waves in space. Their relatively small size, mass, and power consumption, coupled with a good frequency range and sensitivity, make them ideal for spaceflight applications. The basic design of a search coil magnetometer consists of many thousands of turns of wire wound on a high permeability core. When a time-varying magnetic field passes through the coil, a time-varying voltage is induced due to Faraday's law of magnetic induction. The output of the coil is usually attached to a preamplifier, which amplifies the induced voltage and conditions the signal for transmission to the main electronics (usually a low-frequency radio receiver). Search coil magnetometers are usually used in conjunction with electric field antenna to measure electromagnetic plasma waves in the frequency range of a few hertz to a few tens of kilohertzs. Search coil magnetometers are used to determine the properties of waves, such as comparing the relative electric and magnetic field amplitudes of the waves, or to investigate wave propagation parameters, such as Poynting flux and wave normal vectors. On a spinning spacecraft, they are also sometimes used to determine the background magnetic field. This paper presents some of the basic design criteria of search coil magnetometers and discusses design characteristics of sensors flown on a number of spacecraft.

  13. Switching transients in a superconducting coil

    Energy Technology Data Exchange (ETDEWEB)

    Owen, E.W.; Shimer, D.W.

    1983-11-18

    A study is made of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to performance tests on the MFTF Yin-yang coils. It is found that the breaker opening time is the critical factor in determining the size and shape of the transient. Instantaneous opening of the breaker causes a lightly damped transient with large amplitude voltages to ground. Increasing the opening time causes the transient to become a monopulse of decreasing amplitude. The voltages at the external terminals are determined by the parameters of the external circuit. For fast opening times the frequency depends on the dump resistor inductance, the circuit capacitance, and the amplitude on the coil current. For slower openings the dump resistor inductance and the current determine the amplitude of the voltage to ground at the terminals. Voltages to ground are less in the interior of the coil, where transients related to the parameters of the coil itself are observed.

  14. Refurbishment and Testing of the 1970's Era LASS Solenoid Coils for JLab's Hall D

    Energy Technology Data Exchange (ETDEWEB)

    Anumagalla, Ravi; Biallas, George; Brindza, Paul; Carstens, Thomas; Creel, Jonathan; Egiyan, Hovanes; Martin, Floyd; Qiang, Yi; Spiegel, Scot; Stevens, Mark; Wissmann, Mark

    2012-07-01

    JLab refurbished the LASS1, 1.85 m bore Solenoid, consisting of four superconducting coils to act as the principal analysis magnet for nuclear physics in the newly constructed, Hall D at Jefferson Lab. The coils, built in 1971 at Stanford Linier Accelerator Center and used a second time at the MEGA Experiment at Los Alamos, had electrical shorts and leaks to the insulating vacuum along with deteriorated superinsulation & instrumentation. Root cause diagnosis of the problems and the repair methods are described along with the measures used to qualify the vessels and piping within the Laboratory's Pressure Safety Program (mandated by 10CFR851). The extraordinary refrigerator operational methods used to utilize the obsolete cryogenic apparatus gathered for the off-line, single coil tests are described.

  15. Crystal structure of a coiled-coil domain from human ROCK I.

    Directory of Open Access Journals (Sweden)

    Daqi Tu

    Full Text Available The small GTPase Rho and one of its targets, Rho-associated kinase (ROCK, participate in a variety of actin-based cellular processes including smooth muscle contraction, cell migration, and stress fiber formation. The ROCK protein consists of an N-terminal kinase domain, a central coiled-coil domain containing a Rho binding site, and a C-terminal pleckstrin homology domain. Here we present the crystal structure of a large section of the central coiled-coil domain of human ROCK I (amino acids 535-700. The structure forms a parallel α-helical coiled-coil dimer that is structurally similar to tropomyosin, an actin filament binding protein. There is an unusual discontinuity in the coiled-coil; three charged residues (E613, R617 and D620 are positioned at what is normally the hydrophobic core of coiled-coil packing. We speculate that this conserved irregularity could function as a hinge that allows ROCK to adopt its autoinhibited conformation.

  16. Crystal Structure of the Central Coiled-Coil Domain from Human Liprin-[beta]2

    Energy Technology Data Exchange (ETDEWEB)

    Stafford, Ryan L.; Tang, Ming-Yun; Sawaya, Michael R.; Phillips, Martin L.; Bowie, James U. (UCLA)

    2012-02-07

    Liprins are a conserved family of scaffolding proteins important for the proper regulation and development of neuronal synapses. Humans have four liprin-{alpha}s and two liprin-{beta}s which all contain long coiled-coil domains followed by three tandem SAM domains. Complex interactions between the coiled-coil and SAM domains are thought to create liprin scaffolds, but the structural and biochemical properties of these domains remain largely uncharacterized. In this study we find that the human liprin-{beta}2 coiled-coil forms an extended dimer. Several protease-resistant subdomains within the liprin-{beta}1 and liprin-{beta}2 coiled-coils were also identified. A 2.0 {angstrom} crystal structure of the central, protease-resistant core of the liprin-{beta}2 coiled-coil reveals a parallel helix orientation. These studies represent an initial step toward determining the overall architecture of liprin scaffolds and understanding the molecular basis for their synaptic functions.

  17. Coil migration after endovascular coil occlusion of internal carotid artery pseudoaneurysms within the sphenoid sinus.

    Science.gov (United States)

    Struffert, T; Buhk, J H; Buchfelder, M; Rohde, V; Doerfler, A; Knauth, M

    2009-04-01

    We report two cases of coil migration after endovascular treatment of pseudoaneurysm of the internal carotid artery within the sphenoid sinus with coils and noncovered stents. Two patients underwent sphenoid sinus exposure for pituitary adenoma and chronic infection, respectively. As a complication pseudoaneurysms of the internal carotid artery within the sphenoid sinus developed. One patient was treated with stent and coils, the second with coils alone. Both patients experienced coil migration after 9 and 26 months, respectively, with the necessity for further treatment. Imaging was performed using flat detector computed tomography (FD-CT). Literature review revealed two additional cases of coil migration and four patients with the same treatment in stable condition. Pseudoaneurysms of the internal carotid artery are a special entity and the environment of the aneurysm within the sphenoid sinus may change over a long time. Coil embolization may lead to the late onset complication of coil migration with the possible risk of acute epistaxis. As a consequence, these patients need a careful and prolonged follow up. FD-CT is an appropriate technique to visualize the implanted coils and if present the migration of coil material.

  18. Superconducting coil development and motor demonstration: Overview

    Science.gov (United States)

    Gubser, D. U.

    1995-12-01

    Superconducting bismuth-cuprate wires, coils, and magnets are being produced by industry as part of a program to test the viability of using such magnets in Naval systems. Tests of prototype magnets, coils, and wires reveal progress in commercially produced products. The larger magnets will be installed in an existing superconducting homopolar motor and operated initially at 4.2K to test the performance. It is anticipated that approximately 400 Hp will be achieved by the motor. This article reports on the initial tests of the magnets, coils, and wires as well as the development program to improve their performance.

  19. Structured light-based motion tracking in the limited view of an MR head coil

    Energy Technology Data Exchange (ETDEWEB)

    Erikshøj, M., E-mail: martin@erikshoj.dk [DTU-Informatics, Technical University of Denmark (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Righospitalet, University of Copenhagen (Denmark); Olesen, O.V. [DTU-Informatics, Technical University of Denmark (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Righospitalet, University of Copenhagen (Denmark); Conradsen, K. [DTU-Informatics, Technical University of Denmark (Denmark); Højgaard, L. [Department of Clinical Physiology, Nuclear Medicine and PET, Righospitalet, University of Copenhagen (Denmark); Larsen, R. [DTU-Informatics, Technical University of Denmark (Denmark)

    2013-02-21

    A markerless motion tracking (MT) system developed for use in PET brain imaging has been tested in the limited field of view (FOV) of the MR head coil from the Siemens Biograph mMR. The system is a 3D surface scanner that uses structured light (SL) to create point cloud reconstructions of the facial surface. The point clouds are continuously realigned to a reference scan to obtain pose estimates. The system has been tested on a mannequin head performing controlled rotational and translational axial movements within the head coil outside the range of the magnetic field. The RMS of the residual error of the rotation was 0.11° and the RMS difference in the translation with the control system was 0.17 mm, within the trackable range of movement.

  20. Coil Springs Layer Used to Support a Car Vertical Dynamics Simulator and to Reduce the Maximum Actuation Force

    Directory of Open Access Journals (Sweden)

    Dan N. Dumitriu

    2015-09-01

    Full Text Available A Danaher Thomson linear actuator with ball screw drive and a realtime control system are used here to induce vertical displacements under the driver/user seat of an in-house dynamic car simulator. In order to better support the car simulator and to dynamically protect the actuator’s ball screw drive, a layer of coil springs is used to support the whole simulator chassis. More precisely, one coil spring is placed vertically under each corner of the rectangular chassis. The paper presents the choice of the appropriate coil springs, so that to minimize as much as possible the ball screw drive task of generating linear motions, corresponding to the vertical displacements and accelerations encountered by a driver during a real ride. For this application, coil springs with lower spring constant are more suited to reduce the forces in the ball screw drive and thus to increase the ball screw drive life expectancy.

  1. Helical coil thermal hydraulic model

    Science.gov (United States)

    Caramello, M.; Bertani, C.; De Salve, M.; Panella, B.

    2014-11-01

    A model has been developed in Matlab environment for the thermal hydraulic analysis of helical coil and shell steam generators. The model considers the internal flow inside one helix and its associated control volume of water on the external side, both characterized by their inlet thermodynamic conditions and the characteristic geometry data. The model evaluates the behaviour of the thermal-hydraulic parameters of the two fluids, such as temperature, pressure, heat transfer coefficients, flow quality, void fraction and heat flux. The evaluation of the heat transfer coefficients as well as the pressure drops has been performed by means of the most validated literature correlations. The model has been applied to one of the steam generators of the IRIS modular reactor and a comparison has been performed with the RELAP5/Mod.3.3 code applied to an inclined straight pipe that has the same length and the same elevation change between inlet and outlet of the real helix. The predictions of the developed model and RELAP5/Mod.3.3 code are in fairly good agreement before the dryout region, while the dryout front inside the helical pipes is predicted at a lower distance from inlet by the model.

  2. Coil measurement data acquisition and curing press control system for SSC dipole magnet coils

    Energy Technology Data Exchange (ETDEWEB)

    Dickey, C.E.

    1989-03-01

    A coil matching program, similar in theory to the methods used to match Tevatron coils, is being developed at Fermilab. Modulus of elasticity and absolute coil size will be determined at 18-inch intervals along the coils while in the coil curing press immediately following the curing process. A data acquisition system is under construction to automatically acquire and manage the large quantities of data that result. Data files will be transferred to Fermilab's VAX Cluster for long-term storage and actual coil matching. The data acquisition system will also provide the control algorithm for the curing press hydraulic system. A description of the SSC Curing Press Data Acquisition and Controls System will be reported. 20 figs.

  3. Coil geometry effects on scanning single-coil magnetic induction tomography

    Science.gov (United States)

    Feldkamp, Joe R.; Quirk, Stephen

    2017-09-01

    Alternative coil designs for single coil magnetic induction tomography are considered in this work, with the intention of improving upon the standard design used previously. In particular, we note that the blind spot associated with this coil type, a portion of space along its axis where eddy current generation can be very weak, has an important effect on performance. The seven designs tested here vary considerably in the size of their blind spot. To provide the most discerning test possible, we use laboratory phantoms containing feature dimensions similar to blind spot size. Furthermore, conductivity contrasts are set higher than what would occur naturally in biological systems, which has the effect of weakening eddy current generation at coil locations that straddle the border between high and low conductivity features. Image reconstruction results for the various coils show that coils with smaller blind spots give markedly better performance, though improvements in signal-to-noise ratio could alter that conclusion.

  4. Magnetic propulsion of a magnetic device using three square-Helmholtz coils and a square-Maxwell coil.

    Science.gov (United States)

    Ha, Yong H; Han, Byung H; Lee, Soo Y

    2010-02-01

    We introduce a square coil system for remote magnetic navigation of a magnetic device without any physical movements of the coils. We used three square-Helmholtz coils and a square-Maxwell coil for magnetic propulsion of a small magnet along the desired path. All the square coils are mountable on a cubic frame that has an opening to accommodate a living subject. The square-Helmholtz coils control the magnetic propulsion direction by generating uniform magnetic field along the desired direction while the square-Maxwell coil controls the propulsion force by generating magnetic gradient field. We performed magnetic propulsion experiments with a down-scaled coil set and a three-channel coil driver. Experimental results demonstrate that we can use the square coil set for magnetic navigation of a magnetic device without any physical movements of the coils.

  5. Advanced Mud System for Microhole Coiled Tubing Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Oglesby

    2008-12-01

    An advanced mud system was designed and key components were built that augment a coiled tubing drilling (CTD) rig that is designed specifically to drill microholes (less than 4-inch diameter) with advanced drilling techniques. The mud system was tailored to the hydraulics of the hole geometries and rig characteristics required for microholes and is capable of mixing and circulating mud and removing solids while being self contained and having zero discharge capability. Key components of this system are two modified triplex mud pumps (High Pressure Slurry Pumps) for advanced Abrasive Slurry Jetting (ASJ) and a modified Gas-Liquid-Solid (GLS) Separator for well control, flow return and initial processing. The system developed also includes an additional component of an advanced version of ASJ which allows cutting through most all materials encountered in oil and gas wells including steel, cement, and all rock types. It includes new fluids and new ASJ nozzles. The jetting mechanism does not require rotation of the bottom hole assembly or drill string, which is essential for use with Coiled Tubing (CT). It also has low reactive forces acting on the CT and generates cuttings small enough to be easily cleaned from the well bore, which is important in horizontal drilling. These cutting and mud processing components and capabilities compliment the concepts put forth by DOE for microhole coiled tubing drilling (MHTCTD) and should help insure the reality of drilling small diameter holes quickly and inexpensively with a minimal environmental footprint and that is efficient, compact and portable. Other components (site liners, sump and transfer pumps, stacked shakers, filter membranes, etc.. ) of the overall mud system were identified as readily available in industry and will not be purchased until we are ready to drill a specific well.

  6. Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

    Energy Technology Data Exchange (ETDEWEB)

    Holik, Eddie Frank; Ambrosio, Giorgio; Anerella, Michael; Bossert, Rodger; Cavanna, Eugenio; Cheng, Daniel; Dietderich, Daniel R.; Ferracin, Paolo; Ghosh, Arup K.; Izquierdo Bermudez, Susana; Krave, Steven; Nobrega, Alfred; Perez, Juan Carlos; Pong, Ian; Sabbi, GianLuca; Santini, Carlo; Schmalzle, Jesse; Wanderer, Peter; Wang, Xiaorong; Yu, Miao

    2017-01-23

    The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.

  7. Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

    CERN Document Server

    Holik, E F; Anerella, M; Bossert, R; Cavanna, E; Cheng, D; Dietderich, D R; Ferracin, P; Ghosh, A K; Izquierdo Bermudez, S; Krave, S; Nobrega, A; Perez, J C; Pong, I; Sabbi, G L; Santini, C; Schmalzle, J; Wanderer, P; Wang, X; Yu, M

    2017-01-01

    The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D; by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LA...

  8. Functional Analysis of the Bacteriophage T4 Rad50 Homolog (gp46) Coiled-coil Domain.

    Science.gov (United States)

    Barfoot, Tasida; Herdendorf, Timothy J; Behning, Bryanna R; Stohr, Bradley A; Gao, Yang; Kreuzer, Kenneth N; Nelson, Scott W

    2015-09-25

    Rad50 and Mre11 form a complex involved in the detection and processing of DNA double strand breaks. Rad50 contains an anti-parallel coiled-coil with two absolutely conserved cysteine residues at its apex. These cysteine residues serve as a dimerization domain and bind a Zn(2+) cation in a tetrathiolate coordination complex known as the zinc-hook. Mutation of the zinc-hook in bacteriophage T4 is lethal, indicating the ability to bind Zn(2+) is critical for the functioning of the MR complex. In vitro, we found that complex formation between Rad50 and a peptide corresponding to the C-terminal domain of Mre11 enhances the ATPase activity of Rad50, supporting the hypothesis that the coiled-coil is a major conduit for communication between Mre11 and Rad50. We constructed mutations to perturb this domain in the bacteriophage T4 Rad50 homolog. Deletion of the Rad50 coiled-coil and zinc-hook eliminates Mre11 binding and ATPase activation but does not affect its basal activity. Mutation of the zinc-hook or disruption of the coiled-coil does not affect Mre11 or DNA binding, but their activation of Rad50 ATPase activity is abolished. Although these mutants excise a single nucleotide at a normal rate, they lack processivity and have reduced repetitive exonuclease rates. Restricting the mobility of the coiled-coil eliminates ATPase activation and repetitive exonuclease activity, but the ability to support single nucleotide excision is retained. These results suggest that the coiled-coiled domain adopts at least two conformations throughout the ATPase/nuclease cycle, with one conformation supporting enhanced ATPase activity and processivity and the other supporting nucleotide excision.

  9. A Calibrating Device for Rogowski Coil Development

    Institute of Scientific and Technical Information of China (English)

    LV Liang; LI Junhao; HUANG Jianjun; JI Shengchang; LI Yanming

    2007-01-01

    A calibrating device for the Rogowski coil is developed,which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds.Its key component is a step current generator,which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns.The step current generator is composed by a pulse forming line(PFL)and a pulse transmission line(PTL).A TEM(transverse electromagnetic mode)coaxial measurement unit is used as PTL,and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit.The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.

  10. Screen-printed flexible MRI receive coils.

    Science.gov (United States)

    Corea, Joseph R; Flynn, Anita M; Lechêne, Balthazar; Scott, Greig; Reed, Galen D; Shin, Peter J; Lustig, Michael; Arias, Ana C

    2016-03-10

    Magnetic resonance imaging is an inherently signal-to-noise-starved technique that limits the spatial resolution, diagnostic image quality and results in typically long acquisition times that are prone to motion artefacts. This limitation is exacerbated when receive coils have poor fit due to lack of flexibility or need for padding for patient comfort. Here, we report a new approach that uses printing for fabricating receive coils. Our approach enables highly flexible, extremely lightweight conforming devices. We show that these devices exhibit similar to higher signal-to-noise ratio than conventional ones, in clinical scenarios when coils could be displaced more than 18 mm away from the body. In addition, we provide detailed material properties and components performance analysis. Prototype arrays are incorporated within infant blankets for in vivo studies. This work presents the first fully functional, printed coils for 1.5- and 3-T clinical scanners.

  11. Coiling Temperature Control in Hot Strip Mill

    Science.gov (United States)

    Imanari, Hiroyuki; Fujiyama, Hiroaki

    Coiling temperature is one of the most significant factors in products of hot strip mill to determine material properties such as strength, toughness of steel, so it is very important to achieve accurate coiling temperature control (CTC). Usually there are a few pyrometers on the run out table in hot strip mill, therefore temperature model and its adapting system have large influences on the accuracy of CTC. Also unscheduled change of rolling speed has a bad effect to keep coiling temperature as its target. Newly developed CTC system is able to get very accurate coiling temperature against uncertain factors and disturbances by adopting easily identified temperature model, learning method and dynamic set up function. The features of the CTC system are discussed with actual data, and the effectiveness of the system is shown by actual control results.

  12. MR angiography after coiling of intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, J.D.

    2012-01-01

    Introduction Endovascular occlusion with detachable coils has become an alternative treatment to neurosurgical clipping of intracranial aneurysms over the last two decades. Its minimal invasiveness is the most important advantage of this treatment compared to clipping. The disadvantage of occlusion

  13. Mechanical resonances of helically coiled carbon nanowires

    National Research Council Canada - National Science Library

    Saini, D; Behlow, H; Podila, R; Dickel, D; Pillai, B; Skove, M J; Serkiz, S M; Rao, A M

    2014-01-01

    ...) mainly due to their geometrical complexity. The advent of helically coiled micro/nanoscale structures in nano-robotics, nano-inductors, and impact protection coatings has necessitated the development of new methodologies for determining...

  14. The Magnetic Field of Helmholtz Coils

    Science.gov (United States)

    Berridge, H. J. J.

    1975-01-01

    Describes the magnetic field of Helmholtz coils qualitatively and then provides the basis for a quantitative expression. Since the mathematical calculations are very involved, a computer program for solving the mathematical expression is presented and explained. (GS)

  15. Measurement of steady and transient liquid coiling with high-speed video and digital image processing

    Science.gov (United States)

    Mier, Frank Austin; Bhakta, Raj; Castano, Nicolas; Thackrah, Joshua; Marquis, Tyler; Garcia, John; Hargather, Michael

    2016-11-01

    Liquid coiling occurs as a gravitationally-accelerated viscous fluid flows into a stagnant reservoir causing a localized accumulation of settling material, commonly designated as stack. This flow is broadly characterized by a vertical rope of liquid, the tail, flowing into the stack in a coiled motion with frequency defined parametrically within four different flow regimes. These regimes are defined as viscous, gravitational, inertial-gravitational, and inertial. Relations include parameters such as flow rate, drop height, rope radius, gravitational acceleration, and kinematic viscosity. While previous work on the subject includes high speed imaging, only basic and often averaged measurements have been taken by visual inspection of images. Through the implementation of additional image processing routines in MATLAB, time resolved measurements are taken on coiling frequency, tail diameter, stack diameter and height. Synchronization between a high speed camera and stepper motor driven syringe pump provides accurate correlation with flow rate. Additionally, continuous measurement of unsteady transition between flow regimes is visualized and quantified. This capability allows a deeper experimental understanding of processes involved in the liquid coiling phenomenon.

  16. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    accelerator programs. Microsoft runs accelerators in seven different countries. Accelerators have grown out of the infancy stage and are now an accepted approach to develop new ventures based on cutting-edge technology like the internet of things, mobile technology, big data and virtual reality. It is also...... with the traditional audit and legal universes and industries are examples of emerging potentials both from a research and business point of view to exploit and explore further. The accelerator approach may therefore be an Idea Watch to consider, no matter which industry you are in, because in essence accelerators...

  17. Constraint Cooling of Hot Rolled Coil

    Institute of Scientific and Technical Information of China (English)

    WANG Li-juan; ZHANG Chun-li

    2004-01-01

    The layer thermal conductivity during constraint cooling of hot rolled coil was described by using equivalent thermal conductivity model and finite element method. Two radial stress concentration zones in constraint cooled coil were shown by numerical analysis, and the tension stress was assumed to be the main factor to induce stress corrosion. The experimental results show that the longer the water cooling time is, the smaller the grain size and the more uniform the grains are.

  18. NUMERICAL INVESTIGATION FOR THE HEAT TRANSFER ENHANCEMENT IN HELICAL CONE COILS OVER ORDINARY HELICAL COILS

    Directory of Open Access Journals (Sweden)

    M. M. ABO ELAZM

    2013-02-01

    Full Text Available This numerical research is introducing the concept of helical cone coils and their enhanced heat transfer characteristics compared to the ordinary helical coils. Helical and spiral coils are known to have better heat and mass transfer than straight tubes, which is attributed to the generation of a vortex at the helical coil known as Dean Vortex. The Dean number which is a dimensionless number used to describe the Dean vortex is a function of Reynolds number and the square root of the curvature ratio, so varying the curvature ratio for the same coil would vary the Dean number. Two scenarios were adopted to study the effect of changing the taper angle (curvature ratio on the heat transfer characteristics of the coil; the commercial software FLUENT was used in the investigation. It was found that Nusselt number increased with increasing the taper angle. A MATLAB code was built based on empirical correlation of Manlapaz and Churchill for ordinary helical coils to calculate the Nusselt number at each coil turn, and then calculate the average Nusselt number for the entire coil turns, the CFD simulation results were found acceptable when compared with the MATLAB results.

  19. AC loss measurements in HTS coil assemblies with hybrid coil structures

    Science.gov (United States)

    Jiang, Zhenan; Long, Nicholas J.; Staines, Mike; Badcock, Rodney A.; Bumby, Chris W.; Buckley, Robert G.; Amemiya, Naoyuki

    2016-09-01

    Both AC loss and wire cost in coil windings are critical factors for high temperature superconductor (HTS) AC machinery applications. We present AC loss measurement results in three HTS coil assemblies at 77 K and 65 K which have a hybrid coil structure comprising one central winding (CW) and two end windings (EWs) wound with ReBCO and BSCCO wires with different self-field I c values at 77 K. All AC loss results in the coil assemblies are hysteretic and the normalized AC losses in the coil assemblies at different temperatures can be scaled with the I c value of the coil assemblies. The normalised results show that AC loss in a coil assembly with BSCCO CW can be reduced by using EWs wound with high I c ReBCO wires, whilst further AC loss reduction can be achieved by replacing the BSCCO CW with ReBCO CW. The results imply that a flexible hybrid coil structure is possible which considers both AC loss and wire cost in coil assemblies.

  20. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    Accelerators can help to accelerate value creation. Accelerators are short-term programs that have the objective of creating innovative and fast growing ventures. They have gained attraction as larger corporations like Microsoft, Barclays bank and Nordea bank have initiated and sponsored accelera......Accelerators can help to accelerate value creation. Accelerators are short-term programs that have the objective of creating innovative and fast growing ventures. They have gained attraction as larger corporations like Microsoft, Barclays bank and Nordea bank have initiated and sponsored...... an approach to facilitate implementation and realization of business ideas and is a lucrative approach to transform research into ventures and to revitalize regions and industries in transition. Investors have noticed that the accelerator approach is a way to increase the possibility of success by funnelling...

  1. A Condition for a Translation Quiver to Be a Coil

    Institute of Scientific and Technical Information of China (English)

    Bin ZHU; Zong Yi HU

    2003-01-01

    We single out a class of translation quivers and prove combinatorially that the translationquivers in this class are coils. These coils form a class of special coils. They are easier to visualize, butstill show all the strange behaviour of general coils, and contain quasi-stable tubes as special examples.

  2. Experimental analysis on pressure drop and heat transfer of a terminal fan-coil unit with ice slurry as cooling medium

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, J. Alberto [Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, University of Vigo, Campus Lagoas-Marcosende No 9, 36310 Vigo (Spain)

    2010-09-15

    This paper is concerned with the experimental analysis of a standard terminal fan-coil unit with ice slurry as coolant. The ice slurry was produced from an ethylene glycol 10 wt% aqueous solution. The pressure drop measurements are presented as a function of volumetric flow rate, ice concentration and Reynolds number. The experimental friction factors are obtained and discussed. The fan-coil capacity was experimentally determined for chilled water and melting ice slurry with inlet ice fractions around 5, 10, 15 and 20 wt%, considering in each case three different fan rotation velocities. The fan-coil capacity is higher with melting ice slurry than with chilled water by factors between 3.7 and 4.9. The heat transfer analysis realizes that the air side thermal resistance controls the heat transfer process. Experimental results for the melt off rate of ice in the fan coil and the superheating at the fan-coil outlet are shown and discussed. (author)

  3. rotor of the SC rotating condenser

    CERN Multimedia

    1974-01-01

    The rotor of the rotating condenser was installed instead of the tuning fork as the modulating element of the radiofrequency system, when the SC accelerator underwent extensive improvements between 1973 to 1975 (see object AC-025). The SC was the first accelerator built at CERN. It operated from August 1957 until it was closed down at the end of 1990.

  4. A classic zinc finger from friend of GATA mediates an interaction with the coiled-coil of transforming acidic coiled-coil 3.

    Science.gov (United States)

    Simpson, Raina J Y; Yi Lee, Stella Hoi; Bartle, Natalie; Sum, Eleanor Y; Visvader, Jane E; Matthews, Jacqueline M; Mackay, Joel P; Crossley, Merlin

    2004-09-17

    Classic zinc finger domains (cZFs) consist of a beta-hairpin followed by an alpha-helix. They are among the most abundant of all protein domains and are often found in tandem arrays in DNA-binding proteins, with each finger contributing an alpha-helix to effect sequence-specific DNA recognition. Lone cZFs, not found in tandem arrays, have been postulated to function in protein interactions. We have studied the transcriptional co-regulator Friend of GATA (FOG), which contains nine zinc fingers. We have discovered that the third cZF of FOG contacts a coiled-coil domain in the centrosomal protein transforming acidic coiled-coil 3 (TACC3). Although FOG-ZF3 exhibited low solubility, we have used a combination of mutational mapping and protein engineering to generate a derivative that was suitable for in vitro and structural analysis. We report that the alpha-helix of FOG-ZF3 recognizes a C-terminal portion of the TACC3 coiled-coil. Remarkably, the alpha-helical surface utilized by FOG-ZF3 is the same surface responsible for the well established sequence-specific DNA-binding properties of many other cZFs. Our data demonstrate the versatility of cZFs and have implications for the analysis of many as yet uncharacterized cZF proteins.

  5. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  6. Solid catalytic growth mechanism of micro-coiled carbon fibers

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Micro-coiled carbon fibers were prepared by catalytic pyrolysisof acetylene with nano-sized nickel powder catalyst using the substrate method. The morphology of micro-coiled carbon fibers was observed through field emission scanning electron microscopy. It was found that the fiber and coil diameter of the obtained micro-coiled carbon fibers is about 500—600 nm and 4—5 μm, respectively. Most of the micro-coiled carbon fibers obtained were regular double carbon coils, but a few irregular ones were also observed. On the basis of the experimental observation, a solid catalytic growth mechanism of micro-coiled carbon fibers was proposed.

  7. Minimum Inductance Optimal Design for the Gradient Coil

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In MRI (Magnetic Resonance Imaging), a crucial role of gradient coils is to image organism, meanwhile the inductance of the coils determines the speed of imaging. So it is of great importance to optimize designs of the gradient coils. The target field approach is an effective method to design the gradient coils. Having applied this method and performing many numerical tests, we achieved the designs of the x-、y-、z- gradient coils , with the linearity of the fields generated by the coils in a sphere of radius 0.30 m less than 5%, in which the inductance and resistance of the coils also meet the requirements.

  8. Fuel magnetization without external field coils (AutoMag)

    Science.gov (United States)

    Slutz, Stephen; Jennings, Christopher; Awe, Thomas; Shipley, Gabe; Lamppa, Derek; McBride, Ryan

    2016-10-01

    Magnetized Liner Inertial Fusion (MagLIF) has produced fusion-relevant plasma conditions on the Z accelerator where the fuel was magnetized using external field coils. We present a novel concept that does not need external field coils. This concept (AutoMag) magnetizes the fuel during the early part of the drive current by using a composite liner with helical conduction paths separated by insulating material. The drive is designed so the current rises slowly enough to avoid electrical breakdown of the insulators until a sufficiently strong magnetic field is established. Then the current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path and implode the liner. Low inductance magnetically insulated power feeds can be used with AutoMag to increase the drive current without interfering with diagnostic access. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  9. Rotating gravitational lenses: a kinematic approach

    CERN Document Server

    Walters, Steve

    2014-01-01

    This paper uses the Kerr geodesic equations for massless particles to derive an acceleration vector in both Boyer-Lindquist and Cartesian coordinates. As a special case, the Schwarzschild acceleration due to a non-rotating mass has a particularly simple and elegant form in Cartesian coordinates. Using forward integration, these equations are used to plot the caustic pattern due to a system consisting of a rotating point mass with a smaller non-rotating planet. Additionally, first and second order approximations to the paths are identified, which allows for fast approximations of paths, deflection angles and travel-time delays.

  10. Surgical management of an ACM aneurysm eight years after coiling.

    Science.gov (United States)

    Pogády, P; Fellner, F; Trenkler, J; Wurm, G

    2007-04-01

    The authors present a case report on rebleeding of a medial cerebral aneurysm (MCA) eight years after complete endovascular coiling. The primarily successfully coiled MCA aneurysm showed a local regrowth which, however, was not the source of the rebleeding. The angiogram demonstrated no evidence of contrast filling of the coiled segment, but according to intraoperative findings (haematoma location, displacement of coils, evident place of rupture) there is no doubt that the coiled segment of the aneurysm was responsible for the haemorrhage.

  11. Active Vibration Isolation Using a Voice Coil Actuator with Absolute Velocity Feedback Control

    OpenAIRE

    Yun-Hui Liu; Wei-Hao Wu

    2013-01-01

    This paper describes the active vibration isolation using a voice coil actuator with absolute velocity feedback control for highly sensitive instruments (e.g., atomic force microscopes) which suffer from building vibration. Compared with traditional isolators, the main advantage of the proposed isolation system is that it produces no isolator resonance. The absolute vibration velocity signal is acquired from an accelerator and processed through an integrator, and is then input to the controll...

  12. The linear position tracking servo systemusing a linear voice-coil motor

    Institute of Scientific and Technical Information of China (English)

    褚立新; 林辉

    2008-01-01

    More and more linear servo systems have been used in servo applications. Direct drive technology can greatly increase the bandwidth and the tracking accuracy. A position servo-system based on linear voice-coil motor was designed for one linear oscillation movement application. Besides the conventional position, speed and current control loops, the speed and acceleration feed-forward control of command position signal were also used. The experimental test proved the correctness of the design, and the system ...

  13. Design and power conditioning for the coil-gun

    Science.gov (United States)

    Zabar, Z.; Naot, Y.; Burenbaum, L.; Levi, E.; Joshi, P. N.

    This paper describes the power conditioning scheme for a contactless coilgun called the Linear Induction Launcher (LIL) as an open-loop integrated system. The barrel of the LIL consists of a linear array of coils carrying polyphase currents. These create an electromagnetic wave packet which moves with increasing velocity from breech to muzzle, smoothly accelerating a conductive sleeve which carries a set of azimuthal currents sinusoidally distributed along its length, and which encloses the projectile payload. The power conditioner provides high utilization of energy by transferring energy from capacitor to capacitor simultaneously with the projectile movement. A modular construction of the barrel is described together with laboratory results obtained with a breadboard model of the power conditioner circuit.

  14. Reduction of Sample Rotation in Electrostatic Levitation

    Science.gov (United States)

    Hyers, R. W; Johnson, W. L.; Savage, L.; Rogers, J. R.

    2000-01-01

    In many containerless processing systems, control of sample rotation is an important issue. Sample rotation is even more important for microgravity containerless processing systems, where the centrifugal acceleration can approach 1 g for even a small rotation rate. Prior work on rotation control by Rhim focused on driving the sample rotation at a controlled rate for droplet dynamics experiments and measurement of electrical conductivity. His technique allows controlled, fast rotation, but for many microgravity experiments the goal is zero rotation. To minimize sample rotation, two approaches are apparent: first, to identify and balance or eliminate the driving forces for undesired sample rotation, or second, implement a feedback-based rotation control loop in parallel with the position control loop. In this work, we have taken the first approach. To minimize sample rotation, the simplest approach is to identify and balance or eliminate the driving forces for undesired sample rotation. Our experiments show that the dominant driving force for rotation of machined Zr spheres in the MSFC ESL is photon pressure from the heating laser. Experimental results showing the correlation between heating power and torque are compared to theoretical predictions, and a strategy for minimizing the torque due to photon pressure is presented.

  15. Quench Protection of DI-BSCCO Coil

    Science.gov (United States)

    Yamaguchi, T.; Ueno, E.; Kato, T.; Hayashi, K.

    Quench protection is one of the most important requirements for the practical application of high-temperature-superconducting (HTS) coils. Quench protection requires that early detection of a developing quench event is followed by rapid reduction of the operating current. However, such quench detection is very difficult because HTS wire produces heat only locally due to the very slow propagation velocity of a normal zone. Excellent high voltage insulation performance is required if the current is to be reduced rapidly in a large-scale superconducting application with very large inductance. Thus it is important to investigate the behavior of coils with various decay time constants, and to detect voltages on very short time scales. This goal remains to be achieved. In the present study we built test coil and a full-scale pole coil for a 20 MW motor for use in experiments on quench protection, and parameterized the relation between the decay time constant and the detecting voltage, using a conventional balance circuit to detect the quench, which was generated by gradually raising the temperature of the coils. The results verify that a balance circuit can be used for quench detection. For example, when the current decay time constant is 4 seconds, the test coil can be protected even with a detecting voltage of 0.15 volts, despite a significant heat production rate of 126 W. We also confirmed that the full-scale pole coil, with a decay time constant of 20 seconds, can be protected with a detecting voltage of 0.06 V.

  16. Study on the parameters of the scanning system for the 300 keV electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Leo, K. W.; Chulan, R. M., E-mail: leo@nm.gov.my; Hashim, S. A.; Baijan, A. H.; Sabri, R. M.; Mohtar, M.; Glam, H.; Lojius, L.; Zahidee, M.; Azman, A.; Zaid, M. [Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia)

    2016-01-22

    This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.

  17. Microhole High-Pressure Jet Drill for Coiled Tubing

    Energy Technology Data Exchange (ETDEWEB)

    Ken Theimer; Jack Kolle

    2007-06-30

    Tempress Small Mechanically-Assisted High-Pressure Waterjet Drilling Tool project centered on the development of a downhole intensifier (DHI) to boost the hydraulic pressure available from conventional coiled tubing to the level required for high-pressure jet erosion of rock. We reviewed two techniques for implementing this technology (1) pure high-pressure jet drilling and (2) mechanically-assisted jet drilling. Due to the difficulties associated with modifying a downhole motor for mechanically-assisted jet drilling, it was determined that the pure high-pressure jet drilling tool was the best candidate for development and commercialization. It was also determined that this tool needs to run on commingled nitrogen and water to provide adequate downhole differential pressure and to facilitate controlled pressure drilling and descaling applications in low pressure wells. The resulting Microhole jet drilling bottomhole assembly (BHA) drills a 3.625-inch diameter hole with 2-inch coil tubing. The BHA consists of a self-rotating multi-nozzle drilling head, a high-pressure rotary seal/bearing section, an intensifier and a gas separator. Commingled nitrogen and water are separated into two streams in the gas separator. The water stream is pressurized to 3 times the inlet pressure by the downhole intensifier and discharged through nozzles in the drilling head. The energy in the gas-rich stream is used to power the intensifier. Gas-rich exhaust from the intensifier is conducted to the nozzle head where it is used to shroud the jets, increasing their effective range. The prototype BHA was tested at operational pressures and flows in a test chamber and on the end of conventional coiled tubing in a test well. During instrumented runs at downhole conditions, the BHA developed downhole differential pressures of 74 MPa (11,000 psi, median) and 90 MPa (13,000 psi, peaks). The median output differential pressure was nearly 3 times the input differential pressure available from the

  18. In vitro and in vivo delivery of functionalized nanoparticles via coiled-coil interactions

    NARCIS (Netherlands)

    Yang, J.

    2016-01-01

    This thesis presents another approach for direct cytosolic delivery via membrane fusion. This approach is based on a complementary pair of coiled-coil forming peptides, K (KIAALKE)4 and E (EIAALEK)4 and is mimicking the action of the SNARE-complex. The SNARE-complex is responsible for fusion between

  19. Growth Factor Tethering to Protein Nanoparticles via Coiled-Coil Formation for Targeted Drug Delivery.

    Science.gov (United States)

    Assal, Yasmine; Mizuguchi, Yoshinori; Mie, Masayasu; Kobatake, Eiry

    2015-08-19

    Protein-based nanoparticles are attractive carriers for drug delivery because they are biodegradable and can be genetically designed. Moreover, modification of protein-based nanoparticles with cell-specific ligands allows for active targeting abilities. Previously, we developed protein nanoparticles comprising genetically engineered elastin-like polypeptides (ELPs) with fused polyaspartic acid tails (ELP-D). Epidermal growth factor (EGF) was displayed on the surface of the ELP-D nanoparticles via genetic design to allow for active cell-targeting abilities. Herein, we focused on the coiled-coil structural motif as a means for noncovalent tethering of growth factor to ELP-D. Specifically, two peptides known to form a heterodimer via a coiled-coil structural motif were fused to ELP-D and single-chain vascular endothelial growth factor (scVEGF121), to facilitate noncovalent tethering upon formation of the heterodimer coiled-coil structure. Drug-loaded growth factor-tethered ELP-Ds were found to be effective against cancer cells by provoking cell apoptosis. These results demonstrate that tethering growth factor to protein nanoparticles through coiled-coil formation yields a promising biomaterial candidate for targeted drug delivery.

  20. An iterative method for coil sensitivity estimation in multi-coil MRI systems.

    Science.gov (United States)

    Ling, Qiang; Li, Zhaohui; Song, Kaikai; Li, Feng

    2014-12-01

    This paper presents an iterative coil sensitivity estimation method for multi-coil MRI systems. The proposed method works with coil images in the magnitude image domain. It determines a region of support (RoS), a region being composed of the same type of tissues, by a region growing algorithm, which makes use of both intensities and intensity gradients of pixels. By repeating this procedure, it can determine multiple regions of support, which together cover most of the concerned image area. The union of these regions of support provides a rough estimate of the sensitivity of each coil through dividing the intensities of pixels by the average intensity inside every region of support. The obtained rough coil sensitivity estimate is further approached with the product of multiple low-order polynomials, rather than a single one. The product of these polynomials provides a smooth estimate of the sensitivity of each coil. With the obtained sensitivities of coils, it can produce a better reconstructed image, which determines more correct regions of support and yields preciser estimates of the sensitivities of coils. In other words, the method can be iteratively implemented to improve the estimation performance. The proposed method was verified through both simulated data and clinical data from different body parts. The experimental results confirm the superiority of our method to some conventional methods.

  1. A coiled-coil domain acts as a molecular ruler in LPS chain length regulation

    Science.gov (United States)

    Tuukkanen, Anne; Danciu, Iulia; Svergun, Dmitri I.; Hussain, Rohanah; Liu, Huanting; Whitfield, Chris; Naismith, James H.

    2014-01-01

    Long-chain bacterial polysaccharides play important roles in pathogenicity. In Escherichia coli O9a, a model for ABC transporter dependent polysaccharide assembly, a large extracellular carbohydrate with a narrow distribution of size is polymerized from monosaccharides by a complex of two proteins, WbdA (polymerase) and WbdD (terminating protein). Such careful control of polymerization is recurring theme in biology. Combining crystallography and small angle X-ray scattering, we show that the C-terminal domain of WbdD contains an extended coiled-coil that physically separates WbdA from the catalytic domain of WbdD. The effects of insertions and deletions within the coiled-coil region were analyzed in vivo, revealing that polymer size is controlled by varying the length of the coiled-coil domain. Thus, the coiled-coil domain of WbdD functions as a molecular ruler that, along with WbdA:WbdD stoichiometry, controls the chain length of a model bacterial polysaccharide. PMID:25504321

  2. Minimax current density gradient coils: analysis of coil performance and heating.

    Science.gov (United States)

    Poole, Michael S; While, Peter T; Lopez, Hector Sanchez; Crozier, Stuart

    2012-08-01

    Standard gradient coils are designed by minimizing the inductance or resistance for an acceptable level of gradient field nonlinearity. Recently, a new method was proposed to minimize the maximum value of the current density in a coil additionally. The stated aim of that method was to increase the minimum wire spacing and to reduce the peak temperature in a coil for fixed efficiency. These claims are tested in this study with experimental measurements of magnetic field and temperature as well as simulations of the performance of many coils. Experimental results show a 90% increase in minimum wire spacing and 40% reduction in peak temperature for equal coil efficiency and field linearity. Simulations of many more coils indicate increase in minimum wire spacing of between 50 and 340% for the coils studied here. This method is shown to be able to increase coil efficiency when constrained by minimum wire spacing rather than switching times or total power dissipation. This increase in efficiency could be used to increase gradient strength, duty cycle, or buildability.

  3. Golgi coiled-coil proteins contain multiple binding sites for Rab family G proteins

    NARCIS (Netherlands)

    Sinka, Rita; Gillingham, Alison K.; Kondylis, Vangelis; Munro, Sean

    2008-01-01

    Vesicles and other carriers destined for the Golgi apparatus must be guided to the correct cisternae. Golgins, long coiled-coil proteins that localize to particular Golgi subdomains via their C termini, are candidate regulators of vesicle sorting. In this study, we report that the GRIP domain

  4. Golgi coiled-coil proteins contain multiple binding sites for Rab family G proteins

    NARCIS (Netherlands)

    Sinka, Rita; Gillingham, Alison K.; Kondylis, Vangelis; Munro, Sean

    2008-01-01

    Vesicles and other carriers destined for the Golgi apparatus must be guided to the correct cisternae. Golgins, long coiled-coil proteins that localize to particular Golgi subdomains via their C termini, are candidate regulators of vesicle sorting. In this study, we report that the GRIP domain golgin

  5. Advanced approaches for the characterization of a de novo designed antiparallel coiled coil peptide

    NARCIS (Netherlands)

    Pagel, K; Seeger, K; Seiwert, B; Villa, Alessandra; Mark, AE; Berger, S; Koksch, B

    2005-01-01

    We report here an advanced approach for the characterization of the folding pattern of a de novo designed antiparallel coiled coil peptide by high-resolution methods. Incorporation of two fluorescence labels at the C- and N-terminus of the peptide chain as well as modi. cation of two hydrophobic cor

  6. A high-resolution structure that provides insight into coiled-coil thiodepsipeptide dynamic chemistry.

    Science.gov (United States)

    Dadon, Zehavit; Samiappan, Manickasundaram; Shahar, Anat; Zarivach, Raz; Ashkenasy, Gonen

    2013-09-16

    Stable and reactive: A crystal structure at 1.35 Å of a thioester coiled-coil protein reveals high similarity to all-peptide-bond proteins. In these assemblies, the thioester bonds are kept reactive towards thiol molecules in the mixture. This enables efficient domain exchange between proteins in response to changes in folding conditions or introduction of external templates.

  7. Allosteric effects in coiled-coil proteins folding and lanthanide-ion binding.

    Science.gov (United States)

    Samiappan, Manickasundaram; Alasibi, Samaa; Cohen-Luria, Rivka; Shanzer, Abraham; Ashkenasy, Gonen

    2012-10-07

    Peptide sequences modified with lanthanide-chelating groups at their N-termini, or at their lysine side chains, were synthesized, and new Ln(III) complexes were characterized. We show that partial folding of the conjugates to form trimer coiled coil structures induces coordination of lanthanides to the ligand, which in turn further stabilizes the 3D structure.

  8. RECIRCULATING ACCELERATION

    Energy Technology Data Exchange (ETDEWEB)

    BERG,J.S.; GARREN,A.A.; JOHNSTONE,C.

    2000-04-07

    This paper compares various types of recirculating accelerators, outlining the advantages and disadvantages of various approaches. The accelerators are characterized according to the types of arcs they use: whether there is a single arc for the entire recirculator or there are multiple arcs, and whether the arc(s) are isochronous or non-isochronous.

  9. LIBO accelerates

    CERN Multimedia

    2002-01-01

    The prototype module of LIBO, a linear accelerator project designed for cancer therapy, has passed its first proton-beam acceleration test. In parallel a new version - LIBO-30 - is being developed, which promises to open up even more interesting avenues.

  10. Nuclear Magnetic Resonance Structures of GCN4p Are Largely Conserved When Ion Pairs Are Disrupted at Acidic pH but Show a Relaxation of the Coiled Coil Superhelix.

    Science.gov (United States)

    Kaplan, Anne R; Brady, Megan R; Maciejewski, Mark W; Kammerer, Richard A; Alexandrescu, Andrei T

    2017-03-21

    To understand the roles ion pairs play in stabilizing coiled coils, we determined nuclear magnetic resonance structures of GCN4p at three pH values. At pH 6.6, all acidic residues are fully charged; at pH 4.4, they are half-charged, and at pH 1.5, they are protonated and uncharged. The α-helix monomer and coiled coil structures of GCN4p are largely conserved, except for a loosening of the coiled coil quaternary structure with a decrease in pH. Differences going from neutral to acidic pH include (i) an unwinding of the coiled coil superhelix caused by the loss of interchain ion pair contacts, (ii) a small increase in the separation of the monomers in the dimer, (iii) a loosening of the knobs-into-holes packing motifs, and (iv) an increased separation between oppositely charged residues that participate in ion pairs at neutral pH. Chemical shifts (HN, N, C', Cα, and Cβ) of GCN4p display a seven-residue periodicity that is consistent with α-helical structure and is invariant with pH. By contrast, periodicity in hydrogen exchange rates at neutral pH is lost at acidic pH as the exchange mechanism moves into the EX1 regime. On the basis of (1)H-(15)N nuclear Overhauser effect relaxation measurements, the α-helix monomers experience only small increases in picosecond to nanosecond backbone dynamics at acidic pH. By contrast, (13)C rotating frame T1 relaxation (T1ρ) data evince an increase in picosecond to nanosecond side-chain dynamics at lower pH, particularly for residues that stabilize the coiled coil dimerization interface through ion pairs. The results on the structure and dynamics of GCNp4 over a range of pH values help rationalize why a single structure at neutral pH poorly predicts the pH dependence of the unfolding stability of the coiled coil.

  11. Accelerating Inspire

    CERN Document Server

    AUTHOR|(CDS)2266999

    2017-01-01

    CERN has been involved in the dissemination of scientific results since its early days and has continuously updated the distribution channels. Currently, Inspire hosts catalogues of articles, authors, institutions, conferences, jobs, experiments, journals and more. Successful orientation among this amount of data requires comprehensive linking between the content. Inspire has lacked a system for linking experiments and articles together based on which accelerator they were conducted at. The purpose of this project has been to create such a system. Records for 156 accelerators were created and all 2913 experiments on Inspire were given corresponding MARC tags. Records of 18404 accelerator physics related bibliographic entries were also tagged with corresponding accelerator tags. Finally, as a part of the endeavour to broaden CERN's presence on Wikipedia, existing Wikipedia articles of accelerators were updated with short descriptions and links to Inspire. In total, 86 Wikipedia articles were updated. This repo...

  12. Trirotron: triode rotating beam radio frequency amplifier

    Science.gov (United States)

    Lebacqz, Jean V.

    1980-01-01

    High efficiency amplification of radio frequencies to very high power levels including: establishing a cylindrical cloud of electrons; establishing an electrical field surrounding and coaxial with the electron cloud to bias the electrons to remain in the cloud; establishing a rotating electrical field that surrounds and is coaxial with the steady field, the circular path of the rotating field being one wavelength long, whereby the peak of one phase of the rotating field is used to accelerate electrons in a beam through the bias field in synchronism with the peak of the rotating field so that there is a beam of electrons continuously extracted from the cloud and rotating with the peak; establishing a steady electrical field that surrounds and is coaxial with the rotating field for high-energy radial acceleration of the rotating beam of electrons; and resonating the rotating beam of electrons within a space surrounding the second field, the space being selected to have a phase velocity equal to that of the rotating field to thereby produce a high-power output at the frequency of the rotating field.

  13. Analysis and experimental study of wireless power transfer with HTS coil and copper coil as the intermediate resonators system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiufang [School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); School of Physics and Technology, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Nie, Xinyi [School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Liang, Yilang [School of Physics and Technology, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Lu, Falong [School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Yan, Zhongming, E-mail: wangxiufanghappy@163.com [School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Wang, Yu [School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)

    2017-01-15

    Highlights: • We investigated a kind of system architecture with three coils which the repeater is copper coil or HTS coil. • We simulated the different repeater system and obtained the magnetic field distribution at different distance. • We used helical coil instead of pancake coil which does not use capacitors. • HTS intermediate coil has significant effect on improving the transmission efficiency and lengthening transmission distance than copper intermediate coil. - Abstract: Intermediate resonator (repeater) between transmitter and receiver can significantly increase the distance of wireless power transfer (WPT) and the efficiency of wireless power transfer. The wireless power transfer via strongly coupled magnetic resonances with an high temperature superconducting (HTS) coil and copper coil as intermediate resonators was presented in this paper. The electromagnetic experiment system under different conditions with different repeating coils were simulated by finite element software. The spatial distribution patterns of magnetic induction intensity at different distances were plotted. In this paper, we examined transfer characteristics with HTS repeating coil and copper repeating coil at 77 K and 300 K, respectively. Simulation and experimental results show that HTS and copper repeating coil can effectively enhance the space magnetic induction intensity, which has significant effect on improving the transmission efficiency and lengthening transmission distance. We found that the efficiency and the distance of wireless power transfer system with an HTS coil as repeater is much higher by using of copper coil as repeater.

  14. Baculovirus FP25K Localization: Role of the Coiled-Coil Domain.

    Science.gov (United States)

    Garretson, Tyler A; McCoy, Jason C; Cheng, Xiao-Wen

    2016-11-01

    Two types of viruses are produced during the baculovirus life cycle: budded virus (BV) and occlusion-derived virus (ODV). A particular baculovirus protein, FP25K, is involved in the switch from BV to ODV production. Previously, FP25K from the model alphabaculovirus Autographa californica multiple nucleopolyhedrovirus (AcMNPV) was shown to traffic ODV envelope proteins. However, FP25K localization and the domains involved are inconclusive. Here we used a quantitative approach to study FP25K subcellular localization during infection using an AcMNPV bacmid virus that produces a functional AcMNPV FP25K-green fluorescent protein (GFP) fusion protein. During cell infection, FP25K-GFP localized primarily to the cytoplasm, particularly amorphous structures, with a small fraction being localized in the nucleus. To investigate the sequences involved in FP25K localization, an alignment of baculovirus FP25K sequences revealed that the N-terminal putative coiled-coil domain is present in all alphabaculoviruses but absent in betabaculoviruses. Structural prediction indicated a strong relatedness of AcMNPV FP25K to long interspersed element 1 (LINE-1) open reading frame 1 protein (ORF1p), which contains an N-terminal coiled-coil domain responsible for cytoplasmic retention. Point mutations and deletions of this domain lead to a change in AcMNPV FP25K localization from cytoplasmic to nuclear. The coiled-coil and C-terminal deletion viruses increased BV production. Furthermore, a betabaculovirus FP25K protein lacking this N-terminal coiled-coil domain localized predominantly to the nucleus and exhibited increased BV production. These data suggest that the acquisition of this N-terminal coiled-coil domain in FP25K is important for the evolution of alphabaculoviruses. Moreover, with the divergence of preocclusion nuclear membrane breakdown in betabaculoviruses and membrane integrity in alphabaculoviruses, this domain represents an alphabaculovirus adaptation for nuclear trafficking

  15. Critical current studies of a HTS rectangular coil

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Z. [Department of Engineering, University of Cambridge (United Kingdom); Chudy, M., E-mail: Michal.chudy@stuba.sk [Graduate School of Technology Management, University of Pretoria (South Africa); Institute of Power and Applied Electrical Engineering, Slovak University of Technology in Bratislava (Slovakia); Ruiz, H.S. [Department of Engineering, University of Leicester, Leicester LE1 7RH (United Kingdom); Zhang, X.; Coombs, T. [Department of Engineering, University of Cambridge (United Kingdom)

    2017-05-15

    Highlights: • Unique square pancake coil was manufactured. • Measurements in relatively high magnetic field were performed. • Different sections of the coil were characterized. • Parts of the coil which are limiting critical current were identified. - Abstract: Nowadays, superconducting high field magnets are used in numerous applications due to their superior properties. High temperature superconductors (HTS) are usually used for production of circular pancake or racetrack coils. However different geometries of HTS coils might be required for some specific applications. In this study, the HTS coil wound on a rectangular frame was fully characterized in homogeneous DC background field. The study contains measurements of critical current angular dependencies. The critical current of the entire coil and two selected strands under different magnitudes and orientations of external magnetic fields are measured. The critical regions of the coil in different angular regimes are determined. This study brings better understanding of the in- field performance of HTS coils wound on frames with right-angles.

  16. Fabrication of the planar coils for WENDELSTEIN 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Viebke, H. [Max-Planck-Institut fuer Plasmaphysik, Greifswald Branch, Euratom Association, Wendelsteinstrasse 1, D-17491 Greifswald (Germany)]. E-mail: holger.viebke@ipp.mpg.de; Rummel, Th. [Max-Planck-Institut fuer Plasmaphysik, Greifswald Branch, Euratom Association, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Risse, K. [Max-Planck-Institut fuer Plasmaphysik, Greifswald Branch, Euratom Association, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Schroeder, R. [Max-Planck-Institut fuer Plasmaphysik, Greifswald Branch, Euratom Association, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Winter, R. [Tesla Engineering Ltd., Water Lane, Storrington, Sussex RH20 3EA (United Kingdom)

    2005-11-15

    WENDELSTEIN 7-X (W7-X) is a superconducting stellarator, which uses 50 non-planar coils for the main field and 20 planar coils to modify the magnetic configuration. The planar coils are cut into two differently shaped types and designed for 3 T on the plasma axis. A planar coil has an outer diameter of around 4 m. The main elements of planar coils are the winding package, the coil case, the interlayer joints to connect the double layers, and the case cooling with instrumentation. The connection to the coil support structure is performed through forged blocks welded to the casing and bolts. The manufacturing is being performed with a high accuracy to maintain the required symmetry of the magnetic configuration of W7-X. Prior to dispatch the coils pass a works acceptance test at Tesla. After production, all coils are subjected to a functional test at cryogenic temperatures at the Low Temperature Laboratory of CEA at Saclay.

  17. Wireless power transmission applied the mutual coupling between coils

    Science.gov (United States)

    Furuta, Kenta; Baba, Ryouichi; Shun, Endo; Nunokawa, Kazuki; Takahashi, Wataru; Maruyama, Tamami

    2017-07-01

    Recently, the studies of wireless power transfer (WPT) to electric vehicles in motion on the snow-piled road have been reported. In WPT by magnetic field resonance method, transmission coefficient S21, which is one of the scattering parameters, from transmission coil to received coil are degraded because of misalignment of transmitting and receiving coil, the distance between these coils, and the effects of the ice and snow. This paper adopts parasitic coil as a solution to improve the reception power in which the parasitic coil is inserted between transmitting and receiving coils. Analysis and experimental results show that parasitic coil could improve the value of S21 by 15 dB using mutual coupling. LED could be light by this solution when the distance between transmitting and receiving coils are 150 mm.

  18. Classical limits of boot-rotation symmetric spacetimes

    CERN Document Server

    Kofron, David

    2010-01-01

    Boost-rotation symmetric spacetimes are exceptional as they are the only exact asymptotically flat solutions to the Einstein equations describing spatially bounded sources ("point-like" particles, black holes) undergoing non-trivial motion ("uniform acceleration") with radiation. We construct the Newtonian limit of these spacetimes: it yields fields of uniformly accelerated sources in classical mechanics. We also study the special-relativistic limit of the charged rotating C-metric and so find accelerating electromagnetic magic field.

  19. Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

    Science.gov (United States)

    Weavers, Paul T; Borisch, Eric A; Johnson, Casey P; Riederer, Stephen J

    2014-02-01

    In 2D SENSE-accelerated 3D Cartesian acquisition, the net acceleration factor R is the product of the two individual accelerations, R = RY × RZ. Acceleration Apportionment tailors acceleration parameters (RY, RZ) to improve parallel imaging performance on a patient- and coil-specific basis and is demonstrated in contrast-enhanced MR angiography. A performance metric is defined based on coil sensitivity information which identifies the (RY, RZ) pair that optimally trades off image quality with scan time reduction on a patient-specific basis. Acceleration Apportionment is evaluated using retrospective analysis of contrast-enhanced MR angiography studies, and prospective studies in which optimally apportioned parameters are compared with standard acceleration parameters. The retrospective studies show strong variability in optimal acceleration parameters between anatomic regions and between patients. Prospective application of apportionment to foot contrast-enhanced MR angiography with an 8-channel receiver array provides a 20% increase in net acceleration with improved contrast-to-noise ratio. Application to 16-channel contrast-enhanced MR angiography of the feet and calves suggests 10% acceleration increase to R > 13 and no contrast-to-noise ratio loss. The specific implementation allows the optimum (RY, RZ) pair to be determined within one minute. Optimum 2D SENSE acceleration parameters can be automatically chosen on a per-exam basis to allow improved performance without disrupting the clinical workflow. Copyright © 2013 Wiley Periodicals, Inc.

  20. Assembly and Test of a Support Structure for 3.5 m Long Nb3Sn Racetrack Coils.

    Energy Technology Data Exchange (ETDEWEB)

    Ferracin,P.; Ambrosio, G.; Anerella, M.; Caspi, S.; Cheng, D.W.; Felice, H.; Hafalia, A.R.; Hannaford, C.R.; Lietzke, A.F.; Lizarazo, J.; Muratore, J.; Sabbi, G.L.; Schmalzle, J.; Thomas, R.; Wanderer, P.J.

    2007-08-27

    The LHC Accelerator Research Program (LARP) is currently developing 4 m long Nb{sub 3}Sn quadrupole magnets for a possible upgrade of the LHC Interaction Regions (IR). In order to provide a reliable test bed for the fabrication and test of long Nb{sub 3}Sn coils, LARP has started the development of the long racetrack magnet LRS01. The magnet is composed of two 3.6 m long racetrack coils contained in a support structure based on an aluminum shell pre-tensioned with water-pressurized bladders and interference keys. For the phase-one test of the assembly procedure and loading operation, the structure was pre-stressed at room temperature and cooled down to 77 K with instrumented, solid aluminum 'dummy coils'. Mechanical behavior and stress homogeneity were monitored with strain gauges mounted on the shell and the dummy coils. The dummy coils were replaced with reacted and impregnated Nb{sub 3}Sn coils in a second assembly procedure, followed by cool-down to 4.5 K and powered magnet test. This paper reports on the assembly and loading procedures of the support structure as well as the comparison between strain gauge data and 3D model predictions.

  1. Assembly and Test of a Support Structure for 3.6 m Long Nb3Sn Racetrack Coils

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, G.; Anerella, M.; Caspi, S.; Cheng, D.W.; Felice, H.; Hafalia, A.R.; Hannaford, C.R.; Lietzke, A.F.; Lizarazo, J.; Muratore, J.; Sabbi, G.L.; Schmalzle, J.; Thomas, R.; Wanderer, P.J.; Ferracin, P.

    2008-06-01

    The LHC Accelerator Research Program (LARP) is currently developing 4 m long Nb{sub 3}Sn quadrupole magnets for a possible upgrade of the LHC Interaction Regions (IR). In order to provide a reliable test bed for the fabrication and test of long Nb{sub 3}Sn coils, LARP has started the development of the long racetrack magnet LRS01. The magnet is composed of two 3.6 m long racetrack coils contained in a support structure based on an aluminum shell pre-tensioned with water-pressurized bladders and interference keys. For the phase-one test of the assembly procedure and loading operation, the structure was pre-stressed at room temperature and cooled down to 77 K with instrumented, solid aluminum 'dummy coils'. Mechanical behavior and stress homogeneity were monitored with strain gauges mounted on the shell and the dummy coils. The dummy coils were replaced with reacted and impregnated Nb{sub 3}Sn coils in a second assembly procedure, followed by cool-down to 4.5 K and powered magnet test. This paper report on the assembly and loading procedures of the support structure as well as the comparison between strain gauge data and 3D model predictions.

  2. Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil.

    Science.gov (United States)

    Volland, Nelly A; Kholmovski, Eugene G; Parker, Dennis L; Hadley, J Rock

    2013-10-01

    The visualization of lesion formation in real time is one potential benefit of carrying out radiofrequency ablation under magnetic resonance (MR) guidance in the treatment of atrial fibrillation. MR thermometry has the potential to detect such lesions. However, performing MR thermometry during cardiac radiofrequency ablation requires high temporal and spatial resolution and a high signal-to-noise ratio. In this study, a local MR coil (2-cm diameter) was developed to investigate the feasibility of performing limited field of view MR thermometry with high accuracy and speed. The local MR coil allowed high-resolution (1 × 1 × 3 mm(3)) image acquisitions in 76.3 ms with a field of view 64 × 32 mm(2) during an open-chest animal experiment. This represents a 4-fold image acquisition acceleration and an 18-fold field of view reduction compared to that achieved using external MR coils. The signal sensitivity achieved using the local coil was over 20 times greater than that achievable using external coils with the same scan parameters. The local coil configuration provided fewer artifacts and sharper and more stable images. These results demonstrate that MR thermometry can be performed in the heart wall and that lesion formation can be observed during radiofrequency ablation procedures in a canine model. Copyright © 2012 Wiley Periodicals, Inc.

  3. R&D steps of a 12-T common coil dipole magnet for SPPC pre-study

    Science.gov (United States)

    Wang, Chengtao; Zhang, Kai; Xu, Qingjin

    2016-11-01

    IHEP (the Institute of High Energy Physics, Beijing, China) has started the R&D of high field accelerator magnet technology from 2014 for recently proposed CEPC-SppC (Circular Electron Positron Collider, Super proton-proton Collider) project. The conceptual design study of a 20-T dipole magnet is ongoing with the common coil configuration, and a 12-T model magnet will be fabricated in the next two years. A 3-step R&D process has been proposed to realize this 12-T common-coil model magnet: first, a 12-T subscale magnet will be fabricated with Nb3Sn and NbTi superconductors to investigate the fabrication process and characteristics of Nb3Sn coils, then a 12-T subscale magnet will be fabricated with only Nb3Sn superconductors to test the stress management method and quench protection method of Nb3Sn coils; the final step is fabricating the 12-T common-coil dipole magnet with HTS (YBCO) and Nb3Sn superconductors to test the field optimization method of the HTS and Nb3Sn coils. The characteristics of these R&D steps will be introduced in the paper.

  4. Surface Coil for Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Beatriz Taimy Ricardo Ferro

    2015-01-01

    Full Text Available Currently Magnetic Resonance Imaging (MRI, has become a vital tool for the clinical diagnosis of various diseases, especially in the Nervisos Central System and the Musculos keletal System. Coils(RF are an essential component in the generation of these images, are responsible for exciting thespins of nuclei in a sample and/or detect the resultant signal coming from them. The use of surface RF coils has increased considerably, because they have a high signal to noise ratio, a parameter that defines the quality of the image. In the present work, there was realized the theoretical design and practical implementation of a circular surface RF coil. The experimental prototype was optimized to be used in the tomograph Giroimag03  built in Medical Biophysics Center

  5. Determination of Coil Inductances Cylindrical Iron Nucleus

    Directory of Open Access Journals (Sweden)

    Azeddine Mazouz

    2014-03-01

    Full Text Available The paper describes the investigation and development of a structure and performance characteristics of a coil iron nucleus cylindrical (C.I.N.C. The coil iron nucleus cylindrical is a nonlinear electro radio in which the moving of the nucleus in a sense or in other causes change in inductance and can reach extreme values at the superposition of nucleus and coil centers. The variation of the inductance and the degree of freedom of movement of the nucleus can lead to a device with electromechanical conversion The aim of this paper is the determination and visualization of self inductance and mutual of the (C.I.N.C based on geometric dimensions and the displacement of the nucleus.  

  6. CS model coil experimental log book

    Energy Technology Data Exchange (ETDEWEB)

    Nishijima, Gen; Sugimoto, Makoto; Nunoya, Yoshihiko; Wakabayashi, Hiroshi; Tsuji, Hiroshi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2001-02-01

    Charging test of the ITER CS Model Coil which is the world's largest superconducting pulse coil and the CS Insert Coil had started at April 11, 2000 and had completed at August 18, 2000. In the campaign, total shot numbers were 356 and the size of the data file in the DAS (Data Acquisition System) was over 20 GB. This report is a database that consists of the log list and the log sheets of every shot. One can access the database, make a search, and browse results via Internet (http://1ogwww.naka.jaeri.go.jp). The database will be useful to quick search to choose necessary shots. (author)

  7. Acoustic rainbow trapping by coiling up space

    KAUST Repository

    Ni, Xu

    2014-11-13

    We numerically realize the acoustic rainbow trapping effect by tapping an air waveguide with space-coiling metamaterials. Due to the high refractive-index of the space-coiling metamaterials, our device is more compact compared to the reported trapped-rainbow devices. A numerical model utilizing effective parameters is also calculated, whose results are consistent well with the direct numerical simulation of space-coiling structure. Moreover, such device with the capability of dropping different frequency components of a broadband incident temporal acoustic signal into different channels can function as an acoustic wavelength division de-multiplexer. These results may have potential applications in acoustic device design such as an acoustic filter and an artificial cochlea.

  8. Measuring the orthogonality error of coil systems

    Science.gov (United States)

    Heilig, B.; Csontos, A.; Pajunpää, K.; White, Tim; St. Louis, B.; Calp, D.

    2012-01-01

    Recently, a simple method was proposed for the determination of pitch angle between two coil axes by means of a total field magnetometer. The method is applicable when the homogeneous volume in the centre of the coil system is large enough to accommodate the total field sensor. Orthogonality of calibration coil systems used for calibrating vector magnetometers can be attained by this procedure. In addition, the method can be easily automated and applied to the calibration of delta inclination–delta declination (dIdD) magnetometers. The method was tested by several independent research groups, having a variety of test equipment, and located at differing geomagnetic observatories, including: Nurmijärvi, Finland; Hermanus, South Africa; Ottawa, Canada; Tihany, Hungary. This paper summarizes the test results, and discusses the advantages and limitations of the method.

  9. MFTF test coil construction and performance

    Energy Technology Data Exchange (ETDEWEB)

    Cornish, D.N.; Zbasnik, J.P.; Leber, R.L.; Hirzel, D.G.; Johnston, J.E.; Rosdahl, A.R.

    1978-09-25

    A solenoid coil, 105 cm inside the 167 cm outside diameter, has been constructed and tested to study the performance of the stabilized Nb--Ti conductor to be used in the Mirror Fusion Test Facility (MFTF) being built at Lawrence Livermore Laboratory. The insulation system of the test coil is identical to that envisioned for MFTF. Cold-weld joints were made in the conductor at the start and finish of each layer; heaters were fitted to some of these joints and also to the conductor at various locations in the winding. This paper gives details of the construction of the coil and the results of the tests carried out to determine its propagation and recovery characteristics.

  10. The spinning disc: studying radial acceleration and its damping process with smartphone acceleration sensors

    Science.gov (United States)

    Hochberg, K.; Gröber, S.; Kuhn, J.; Müller, A.

    2014-03-01

    Here, we show the possibility of analysing circular motion and acceleration using the acceleration sensors of smartphones. For instance, the known linear dependence of the radial acceleration on the distance to the centre (a constant angular frequency) can be shown using multiple smartphones attached to a revolving disc. As a second example, the decrease of the radial acceleration and the rotation frequency due to friction can be measured and fitted with a quadratic function, in accordance with theory. Finally, because the disc is not set up exactly horizontal, each smartphone measures a component of the gravitational acceleration that adds to the radial acceleration during one half of the period and subtracts from the radial acceleration during the other half. Hence, every graph shows a small modulation, which can be used to determine the rotation frequency, thus converting a ‘nuisance effect’ into a source of useful information, making additional measurements with stopwatches or the like unnecessary.

  11. High Temperature Superconductor Accelerator Magnets

    CERN Document Server

    AUTHOR|(CDS)2079328; de Rijk, Gijs; Dhalle, Marc

    2016-11-10

    For future particle accelerators bending dipoles are considered with magnetic fields exceeding $20T$. This can only be achieved using high temperature superconductors (HTS). These exhibit different properties from classical low temperature superconductors and still require significant research and development before they can be applied in a practical accelerator magnet. In order to study HTS in detail, a five tesla demonstrator magnet named Feather-M2 is designed and constructed. The magnet is based on ReBCO coated conductor, which is assembled into a $10kA$ class Roebel cable. A new and optimized Aligned Block layout is used, which takes advantage of the anisotropy of the conductor. This is achieved by providing local alignment of the Roebel cable in the coil windings with the magnetic field lines. A new Network Model capable of analyzing transient electro-magnetic and thermal phenomena in coated conductor cables and coils is developed. This model is necessary to solve critical issues in coated conductor ac...

  12. Resistive demountable toroidal-field coils for tokamak reactors

    Energy Technology Data Exchange (ETDEWEB)

    Jassby, D.L.; Jacobsen, R.A.; Kalnavarns, J.; Masson, L.S.; Sekot, J.P.

    1981-07-01

    Readily demountable TF (toroidal-field) coils allow complete access to the internal components of a tokamak reactor for maintenance of replacement. The requirement of readily demountable joints dictates the use of water-cooled resistive coils, which have a host of decisive advantages over superconducting coils. Previous papers have shown that resistive TF coils for tokamak reactors can operate in the steady state with acceptable power dissipation (typically, 175 to 300 MW). This paper summarizes results of parametric studies of size optimization of rectangular TF coils and of a finite-element stress analysis, and examines several candidate methods of implementing demountable joints for rectangular coils constructed of plate segments.

  13. Analytical and experimental analysis of tube coil heat exchanger

    Science.gov (United States)

    Smusz, R.

    2016-09-01

    The paper presents the analytical and experimental analysis of heat transfer for the finned tube coil heat exchanger immersed in thermal storage tank. The tank is equipped with three helical-shaped heating coils and cylindrical- shaped stratification device. Two coils, upper and lower, use the water as a heating medium. The third, double wall heat exchanger coil, located at the bottom head on the tank is filled by the refrigerant (freon). Calculations of thermal power of water coil were made. Correlations of heat transfer coefficients in curved tubes were applied. In order to verify the analytical calculations the experimental studies of heat transfer characteristic for coil heat exchanger were performed.

  14. Final design and construction of the Wendelstein7-X coils

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, L. E-mail: lutz.wegener@ipp.mpg.de; Feist, J.-H.; Sapper, J.; Kerl, F.; Werner, F

    2001-11-01

    The Stellarator of the Wendelstein 7-X (W7-X) experiment contains a system of 50 non-planar and 20 planar superconducting coils. The coils were designed by the IPP. The coil manufacturing and inspection is shared between several European enterprises and consortiums. The coils consist of the winding pack embedded in a stainless steel casing and of the related instrumentation. Design details, tolerances and guarantee values and differences between the coils types are described in the contribution. The features of the superconductor are described separately. Finally, the contribution indicates measures adopted by the W7-X project to ensure the quality of the coil design and manufacturing.

  15. Coiled coil interactions for the targeting of liposomes for nucleic acid delivery

    Science.gov (United States)

    Oude Blenke, Erik E.; van den Dikkenberg, Joep; van Kolck, Bartjan; Kros, Alexander; Mastrobattista, Enrico

    2016-04-01

    Coiled coil interactions are strong protein-protein interactions that are involved in many biological processes, including intracellular trafficking and membrane fusion. A synthetic heterodimeric coiled-coil forming peptide pair, known as E3 (EIAALEK)3 and K3 (KIAALKE)3 was used to functionalize liposomes encapsulating a splice correcting oligonucleotide or siRNA. These peptide-functionalized vesicles are highly stable in solution but start to cluster when vesicles modified with complementary peptides are mixed together, demonstrating that the peptides quickly coil and crosslink the vesicles. When one of the peptides was anchored to the cell membrane using a hydrophobic cholesterol anchor, vesicles functionalized with the complementary peptide could be docked to these cells, whereas non-functionalized cells did not show any vesicle tethering. Although the anchored peptides do not have a downstream signaling pathway, microscopy pictures revealed that after four hours, the majority of the docked vesicles were internalized by endocytosis. Finally, for the first time, it was shown that the coiled coil assembly at the interface between the vesicles and the cell membrane induces active uptake and leads to cytosolic delivery of the nucleic acid cargo. Both the siRNA and the splice correcting oligonucleotide were functionally delivered, resulting respectively in the silencing or recovery of luciferase expression in the appropriate cell lines. These results demonstrate that the docking to the cell by coiled coil interaction can induce active uptake and achieve the successful intracellular delivery of otherwise membrane impermeable nucleic acids in a highly specific manner.Coiled coil interactions are strong protein-protein interactions that are involved in many biological processes, including intracellular trafficking and membrane fusion. A synthetic heterodimeric coiled-coil forming peptide pair, known as E3 (EIAALEK)3 and K3 (KIAALKE)3 was used to functionalize liposomes

  16. Self-assembling segmented coiled tubing

    Energy Technology Data Exchange (ETDEWEB)

    Raymond, David W.

    2016-09-27

    Self-assembling segmented coiled tubing is a concept that allows the strength of thick-wall rigid pipe, and the flexibility of thin-wall tubing, to be realized in a single design. The primary use is for a drillstring tubular, but it has potential for other applications requiring transmission of mechanical loads (forces and torques) through an initially coiled tubular. The concept uses a spring-loaded spherical `ball-and-socket` type joint to interconnect two or more short, rigid segments of pipe. Use of an optional snap ring allows the joint to be permanently made, in a `self-assembling` manner.

  17. Multiple coil closure of isolated aortopulmonary collateral

    Directory of Open Access Journals (Sweden)

    Padhi Sumanta

    2010-01-01

    Full Text Available A 7-month-old girl was diagnosed to have large aortopulmonary collateral during evaluation for congestive heart failure. There was no other evidence of cardiopulmonary disease. The collateral was successfully closed with multiple coils delivered sequentially. We describe the issues associated during closure of the aortopulmonary collateral in this case. To the best of our knowledge, this is the first reported case of large aortopulmonary collateral presenting with heart failure in an otherwise structurally normal heart that was closed successfully with multiple coils delivered sequentially.

  18. A HTS dipole insert coil constructed

    CERN Document Server

    Ballarino, A; Rey, J M; Stenvall, A; Sorbi, M; Tixador, P

    2013-01-01

    This report is the deliverable report 7.4.1 “A HTS dipole insert coil constructed“. The report has three parts: “Design report for the HTS dipole insert”, “One insert pancake prototype coil constructed with the setup for a high field test”, and “All insert components ordered”. The three report parts show that, although the insert construction will be only completed by end 2013, all elements are present for a successful completion and that, given the important investments done by the participants, there is a full commitment of all of them to finish the project

  19. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  20. Estimation and measurement of flat or solenoidal coil inductance for radiofrequency NMR coil design.

    Science.gov (United States)

    Rainey, Jan K; DeVries, Jeffrey S; Sykes, Brian D

    2007-07-01

    The inductance of a radiofrequency coil determines its compatibility with a given NMR probe circuit. However, calculation (or estimation) of inductance for radiofrequency coils of dimensions suitable for use in an NMR probe is not trivial, particularly for flat-coils. A comparison of a number of formulae for calculation of inductance is presented through the use of a straightforward inductance measurement circuit. This technique relies upon instrumentation available in many NMR laboratories rather than upon more expensive and specialized instrumentation often utilized in the literature. Inductance estimation methods are suggested and validated for both flat-coils and solenoids. These have proven very useful for fabrication of a number of new coils in our laboratory for use in static solid-state NMR probes operating at (1)H frequencies of 300 and 600MHz. Solenoidal coils with very similar measured and estimated inductances having inner diameters from 1 to 5mm are directly compared as an example of the practical application of inductance estimation for interchange of coils within an existing solid-state NMR probe.

  1. Research and development of MRI surface coil for TMJ MR imaging; Modulated Helmholtz surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Kukimoto, Yoshiaki; Kukimoto, Kyoko (Kameda General Hospital, Kamogawa, Chiba (Japan)); Shirakawa, Toyomi

    1989-12-01

    Internal derangements of the temporomandibular joint (TMJ) are a major cause of jaw pain and dysfunction as well as other related clinical symptoms. TMJ diagnosis is the abnormal position and appearance of the disk. Most X-ray-based methods are useful for evaluating bony abnormalities, but their reduced soft-tissue contrast often makes the diagnostic evaluation of TMJ disorders difficult. Magnetic resonance (MR) imaging is a very recent addition to the medical diagnostic of TMJ diseases. MR imaging can produce high-quality tomographic images of greater soft-tissue contrast without ionizing radiation or known biological hazards. MR system was circular type Simens Magnetom 1.5 tesla. Display matrix was 256x256. A Modulated Helmholtz type coil of 17 cm in diameter was developed in Kameda General Hospital in order to increase signal to noise ratio in the area of bilateral TMJs. The distance between two coils was 16-20 cm. The head was placed in supine position in the center of two surface coils. A Modulated Helmholtz type coil: 1. Modulated Helmholtz type coil was used as an emitter and a receiver. 2. Modulated Helmholtz type coil had a pair of 17 cm coils, which were movable according to head width of each patient. 3. MR imaging of bilateral TMJs was taken at once because of no necessity to reset a surfacecoil. 4. It was easy to set positioning of the head. (author).

  2. A Missile-Borne Angular Velocity Sensor Based on Triaxial Electromagnetic Induction Coils

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-09-01

    Full Text Available Aiming to solve the problem of the limited measuring range for angular motion parameters of high-speed rotating projectiles in the field of guidance and control, a self-adaptive measurement method for angular motion parameters based on the electromagnetic induction principle is proposed. First, a framework with type bent “I-shape” is used to design triaxial coils in a mutually orthogonal way. Under the condition of high rotational speed of a projectile, the induction signal of the projectile moving across a geomagnetic field is acquired by using coils. Second, the frequency of the pulse signal is adjusted self-adaptively. Angular velocity and angular displacement are calculated in the form of periodic pulse counting and pulse accumulation, respectively. Finally, on the basis of that principle prototype of the sensor is researched and developed, performance of measuring angular motion parameters are tested on the sensor by semi-physical and physical simulation experiments, respectively. Experimental results demonstrate that the sensor has a wide measuring range of angular velocity from 1 rps to 100 rps with a measurement error of less than 0.3%, and the angular displacement measurement error is lower than 0.2°. The proposed method satisfies measurement requirements for high-speed rotating projectiles with an extremely high dynamic range of rotational speed and high precision, and has definite value to engineering applications in the fields of attitude determination and geomagnetic navigation.

  3. Proto-CIRCUS Tilted-Coil Tokamak-Torsatron Hybrid: Design and Construction

    CERN Document Server

    Clark, A W; Hammond, K C; Kornbluth, Y; Spong, D A; Sweeney, R; Volpe, F A

    2014-01-01

    We present the field-line modeling, design and construction of a prototype circular-coil tokamak-torsatron hybrid called Proto-CIRCUS. The device has a major radius R = 16 cm and minor radius a < 5 cm. The six "toroidal field" coils are planar as in a tokamak, but they are tilted. This, combined with induced or driven plasma current, is expected to generate rotational transform, as seen in field-line tracing and equilibrium calculations. The device is expected to operate at lower plasma current than a tokamak of comparable size and magnetic field, which might have interesting implications for disruptions and steady-state operation. Additionally, the toroidal magnetic ripple is less pronounced than in an equivalent tokamak in which the coils are not tilted. The tilted coils are interlocked, resulting in a relatively low aspect ratio, and can be moved, both radially and in tilt angle, between discharges. This capability will be exploited for detailed comparisons between calculations and field-line mapping me...

  4. Study and Design of a Linear Compressor of Voice-Coil Typ

    Directory of Open Access Journals (Sweden)

    VADAN, I.

    2009-06-01

    Full Text Available The paper presents the design and Finite Element (FEM analysis of a Linear compressor of voice coil type (LCVCT. This kind of linear compressor will be used in a refrigerator equipment. It is well-known that the replacing of the rotating compressor from a classical refrigerator by a linear compressor leads to an efficiency improving wit about 5% by avoiding the piston side friction, which is very important because of the huge number of refrigerators in operation world-wide. The linear compressor refrigerator is already commercially available in South Korea, equipped with an electromagnetic (fix coil and moving permanent magnet linear compressor. This paper presents a new type of linear compressor - a voice-coil type (fixed permanent magnet and moving coil. The operation principle is the same as for electrodynamic vibrator or electro-dynamic loud-speaker. The designing with rare earth permanent magnet is not a simple problem, because of the nonlinear characteristic of rare earth magnets. A magneto-static FEM analysis has been performed in order to validate the design methodology proposed in the paper.

  5. Future accelerators

    CERN Document Server

    Hübner, K

    1999-01-01

    An overview of the various schemes for electron-positron linear colliders is given and the status of the development of key components and the various test facilities is given. The present studies of muon-muon colliders and very large hadron colliders are summarized including the plans for component development and tests. Accelerator research and development to achieve highest gradients in linear accelerators is outlined. (44 refs).

  6. 一种旋转角加速度传感器标定方法的研究%Research of a Calibration Method for Rotating Angular Acceleration Sensor

    Institute of Scientific and Technical Information of China (English)

    赵浩; 冯浩

    2016-01-01

    针对旋转角加速度传感器标定困难这一问题,提出了一种能够校准旋转角加速度传感器的方法。角加速度激励源采用伺服电动机产生,被校准的传感器与激励源同轴连接,通过调节激励源的电参数,能够产生幅值可调的旋转角加速度量值,测取角加速度传感器的输出电压值后即可实现标定。本文详细阐述了激励源的角加速度产生机理,推导了角加速度量值的理论公式,给出了计算角加速度量值所需参数的测取方法,最后对感应式角加速度传感器进行了校准实验,验证了标定方法的可行性。%For the calibration problem of angular acceleration sensor,a calibration method is presented in this paper. The angular acceleration excitation source is generated by servo motor,and angular acceleration sensor is connected with the excitation source coaxially. The amplitude of angular acceleration can be adjusted by adjusting electrical pa⁃rameters of excitation source,the characteristic of sensor is received after measuring the sensor output voltage. In this paper,the working mechanism of angular acceleration excitation source is described in detail,the theoretical for⁃mula of angular acceleration is deduced,and the parameters measuring method for calculating angular acceleration is given. Finally,a induction angular acceleration sensor is calibrated by this method,and the feasibility is verified.

  7. Rotation of vertically oriented objects during earthquakes

    Science.gov (United States)

    Hinzen, Klaus-G.

    2012-10-01

    Vertically oriented objects, such as tombstones, monuments, columns, and stone lanterns, are often observed to shift and rotate during earthquake ground motion. Such observations are usually limited to the mesoseismal zone. Whether near-field rotational ground motion components are necessary in addition to pure translational movements to explain the observed rotations is an open question. We summarize rotation data from seven earthquakes between 1925 and 2009 and perform analog and numeric rotation testing with vertically oriented objects. The free-rocking motion of a marble block on a sliding table is disturbed by a pulse in the direction orthogonal to the rocking motion. When the impulse is sufficiently strong and occurs at the `right' moment, it induces significant rotation of the block. Numeric experiments of a free-rocking block show that the initiation of vertical block rotation by a cycloidal acceleration pulse applied orthogonal to the rocking axis depends on the amplitude of the pulse and its phase relation to the rocking cycle. Rotation occurs when the pulse acceleration exceeds the threshold necessary to provoke rocking of a resting block, and the rocking block approaches its equilibrium position. Experiments with blocks subjected to full 3D strong motion signals measured during the 2009 L'Aquila earthquake confirm the observations from the tests with analytic ground motions. Significant differences in the rotational behavior of a monolithic block and two stacked blocks exist.

  8. Optimization of Plasma Performance by RWM Stabilization Using the I-Coil in DIII-D

    Science.gov (United States)

    Garofalo, A. M.; Navratil, G. A.; Reimerdes, H.; Jackson, G. L.; Jensen, T. H.; Schaffer, M. J.; Scoville, J. T.; Strait, E. J.; Turnbull, A. D.; Jayakumar, R. J.; Okabayashi, M.

    2003-10-01

    Stabilization of the resistive wall mode by plasma rotation has opened access to reliable tokamak operation at β above the n=1 no-wall limit. In order to maintain the fluid rotation speed that is necessary to stabilize the RWM, it is critical to avoid the braking produced by magnetic field asymmetries in this β regime. RWM feedback operation at high stable gain using the C-coil in DIII-D provided a method to determine the optimal correction of these magnetic field errors. The working paradigm was that the feedback system senses and opposes the resonant response of the stable RWM to the field asymmetries. The new internal control coil in DIII-D, the I-coil, has afforded us additional degrees of freedom for the poloidal and toroidal spectra of the external fields. Comparing the optimized magnetic configurations obtained with different spectra provides both a new test of our paradigm and information that can illustrate the mechanism by which field asymmetries interact with the plasma.

  9. Tx/Rx Head Coil Induces Less RF Transmit-Related Heating than Body Coil in Conductive Metallic Objects Outside the Active Area of the Head Coil.

    Science.gov (United States)

    Nagy, Zoltan; Oliver-Taylor, Aaron; Kuehne, Andre; Goluch, Sigrun; Weiskopf, Nikolaus

    2017-01-01

    The transmit-receive (Tx/Rx) birdcage head coil is often used for excitation instead of the body coil because of the presumably lower risk of heating in and around conductive implants. However, this common practice has not been systematically tested. To investigate whether the Tx/Rx birdcage head coil produces less heating than the body coil when scanning individuals with implants, we used a 3T clinical scanner and made temperature measurements around a straight 15 cm conductor using either the Tx/Rx body or the head coil for excitation. Additionally, the transmitted fields of a Tx/Rx head coil were measured both in air and in gel using a resonant and a non-resonant B field probes as well as a non-resonant E field probe. Simulations using a finite-difference time domain solver were compared with the experimental findings. When the body coil was used for excitation, we observed heating around the 15 cm wire at various anatomical locations (both within and outside of the active volume of the head coil). Outside its active area, no such heating was observed while using the Tx/Rx head coil for excitation. The E and B fields of the Tx/Rx birdcage head coil extended well-beyond the physical dimensions of the coil. In air, the fields were monotonically decreasing, while in gel they were more complex with local maxima at the end of the ASTM phantom. These experimental findings were line with the simulations. While caution must always be exercised when scanning individuals with metallic implants, these findings support the use of the Tx/Rx birdcage head coil in place of the body coil at 3T in order to reduce the risk of heating in and around conductive implants that are remote from the head coil.

  10. Tx/Rx Head Coil Induces Less RF Transmit-Related Heating than Body Coil in Conductive Metallic Objects Outside the Active Area of the Head Coil

    Science.gov (United States)

    Nagy, Zoltan; Oliver-Taylor, Aaron; Kuehne, Andre; Goluch, Sigrun; Weiskopf, Nikolaus

    2017-01-01

    The transmit–receive (Tx/Rx) birdcage head coil is often used for excitation instead of the body coil because of the presumably lower risk of heating in and around conductive implants. However, this common practice has not been systematically tested. To investigate whether the Tx/Rx birdcage head coil produces less heating than the body coil when scanning individuals with implants, we used a 3T clinical scanner and made temperature measurements around a straight 15 cm conductor using either the Tx/Rx body or the head coil for excitation. Additionally, the transmitted fields of a Tx/Rx head coil were measured both in air and in gel using a resonant and a non-resonant B field probes as well as a non-resonant E field probe. Simulations using a finite-difference time domain solver were compared with the experimental findings. When the body coil was used for excitation, we observed heating around the 15 cm wire at various anatomical locations (both within and outside of the active volume of the head coil). Outside its active area, no such heating was observed while using the Tx/Rx head coil for excitation. The E and B fields of the Tx/Rx birdcage head coil extended well-beyond the physical dimensions of the coil. In air, the fields were monotonically decreasing, while in gel they were more complex with local maxima at the end of the ASTM phantom. These experimental findings were line with the simulations. While caution must always be exercised when scanning individuals with metallic implants, these findings support the use of the Tx/Rx birdcage head coil in place of the body coil at 3T in order to reduce the risk of heating in and around conductive implants that are remote from the head coil.

  11. Microscopic Faraday rotation measurement system using pulsed magnetic fields.

    Science.gov (United States)

    Egami, Shigeki; Watarai, Hitoshi

    2009-09-01

    Microscopic Faraday rotation measurement system using a pulsed magnetic field has been constructed, which can be applied to micron sized diamagnetic and paramagnetic materials. A pulsed magnetic coil could generate a maximum magnetic flux density of about 12 T. The performance of the microscopic Faraday rotation apparatus was demonstrated by the measurement of the Verdet constant V of a polystyrene particle, after the calibration of the pulsed magnetic flux density using a glass plate as a standard material. Also, the magneto-optical rotation dispersion of some diamagnetic substances have been measured and analyzed with V=alambda(-2)+b. The values of a and b were compared to their magnetic susceptibilities.

  12. Optimization of a conduction-cooled LTS pulse coil

    Energy Technology Data Exchange (ETDEWEB)

    Kawagoe, A. [Kagoshima University, Kohrimoto 1-21-40, Kagoshima-shi, Kagoshima 890-0065 (Japan)]. E-mail: kawagoe@eee.kagoshima-u.ac.jp; Yamamuro, H. [Kagoshima University, Kohrimoto 1-21-40, Kagoshima-shi, Kagoshima 890-0065 (Japan); Sumiyoshi, F. [Kagoshima University, Kohrimoto 1-21-40, Kagoshima-shi, Kagoshima 890-0065 (Japan); Mito, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Chikaraishi, H. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Hemmi, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Baba, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Yokota, M. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Morita, Y. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Ogawa, H. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Abe, R. [Shibuya Kogyo Co., Ltd., Kanazawa, Ishikawa 920-0054 (Japan); Okumura, K. [Technova Inc., Chiyoda-ku, Tokyo 100-0011 (Japan); Iwakuma, M. [Kyushu University, Higashi-ku, Fukuoka 812-8581 (Japan)

    2006-11-15

    The output limit of the available power of a prototype conduction-cooled low temperature superconducting (LTS) pulse coil is clarified for the optimization of the coil. The winding conductor of this coil is a NbTi/Cu Rutherford cable, which is extruded with aluminum. Dyneema[reg] fiber reinforced plastics (DFRP) and Litz wires are used as the spacers of this coil. A prototype coil with a stored energy of 100 kJ was successfully fabricated and tested, and the coil performed excellently. In this paper, the stability margin of this coil is clarified by thermal analysis, using a two-dimensional finite element method, taking into account the effects of both types of spacers, DFRP and Litz wires. Additionally, the maximum output power of the coil is estimated at about three times the rated output.

  13. Constrained length minimum inductance gradient coil design.

    Science.gov (United States)

    Chronik, B A; Rutt, B K

    1998-02-01

    A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constraints on the final current density is presented. This constrained current minimum inductance method is derived in the context of previous target field methods. Complete details are shown and all equations required for implementation of the algorithm are given. The method has been implemented on computer and applied to the design of both a 1:1 aspect ratio (length:diameter) central ROI and a 2:1 aspect ratio edge ROI gradient coil. The 1:1 design demonstrates that a general analytic method can be used to easily obtain very short gradient coil designs for use with specialized magnet systems. The edge gradient design demonstrates that designs that allow imaging of the neck region with a head sized gradient coil can be obtained, as well as other applications requiring edge-of-cylinder regions of uniformity.

  14. Thermophoresis of polymers: nondraining vs draining coil.

    Science.gov (United States)

    Morozov, Konstantin I; Köhler, Werner

    2014-06-10

    Present theories for the thermophoretic mobility of polymers in dilute solution without long-ranged electrostatic interaction are based on a draining coil model with short-ranged segment-solvent interaction. We show that the characteristic thermophoretic interaction decays as r(-2) with the distance from the chain segment, which is of much longer range than the underlying rapidly decaying binary van der Waals interaction (∝ r(-6)). As a consequence, thermophoresis on the monomer level is governed by volume forces, resulting in hydrodynamic coupling between the chain segments. The inner parts of the nondraining coil do not actively participate in thermophoresis. The flow lines penetrate only into a thin surface layer of the coil and cause tangential stresses along the surface of the entire coil, not the individual segments. This model is motivated by recent experimental findings for thermoresponsive polymers and core-shell particles, and it explains the well-known molar mass independent thermophoretic mobility of polymers in dilute solution.

  15. Coil in bottom part of splitter magnet

    CERN Multimedia

    1976-01-01

    Radiation-resistant coil being bedded into the bottom part of a splitter magnet. This very particular magnet split the beam into 3 branches, for 3 target stations in the West-Area. See Annual Report 1975, p.176, Figs.14 and 15.

  16. Stellarator Coil Design and Plasma Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Long-Poe Ku and Allen H. Boozer

    2010-11-03

    The rich information contained in the plasma response to external magnetic perturbations can be used to help design stellarator coils more effectively. We demonstrate the feasibility by first devel- oping a simple, direct method to study perturbations in stellarators that do not break stellarator symmetry and periodicity. The method applies a small perturbation to the plasma boundary and evaluates the resulting perturbed free-boundary equilibrium to build up a sensitivity matrix for the important physics attributes of the underlying configuration. Using this sensitivity information, design methods for better stellarator coils are then developed. The procedure and a proof-of-principle application are given that (1) determine the spatial distributions of external normal magnetic field at the location of the unperturbed plasma boundary to which the plasma properties are most sen- sitive, (2) determine the distributions of external normal magnetic field that can be produced most efficiently by distant coils, (3) choose the ratios of the magnitudes of the the efficiently produced magnetic distributions so the sensitive plasma properties can be controlled. Using these methods, sets of modular coils are found for the National Compact Stellarator Experiment (NCSX) that are either smoother or can be located much farther from the plasma boundary than those of the present design.

  17. Penile hair coil strangulation of the child

    African Journals Online (AJOL)

    shanker

    We report the case of a child with a delayed presentation of penile strangulation with a coil of hair that resulted in a complete ... erection in some of them and with autoerotic intentions in others. ... in children with underlying urological problems.

  18. High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi [Department of Radiology, University of Tsukuba, Tsukuba (Japan); Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, 02115, Boston, MA (United States); Ueno, Teruko; Itai, Yuji [Department of Radiology, University of Tsukuba, Tsukuba (Japan); Tanaka, Toshikazu [Department of Orthopedic Surgery, Tsukuba Kinen Hospital, Tsukuba (Japan); Shindo, Masashi [Tsukuba University Hospital, Tsukuba (Japan)

    2003-10-01

    To compare MR images of the triangular fibrocartilage complex (TFCC) using microscopy coils with those using a conventional surface coil qualitatively and quantitatively. Proton density-weighted images and T2*-weighted images of the TFCC from ten normal volunteers were obtained with a conventional surface coil (C4 coil; 80 mm in diameter), a 47-mm microscopy surface coil and a 23-mm microscopy surface coil at 1.5 T. Qualitative image analysis of MR images with three coils was performed by two radiologists who assigned one of five numerical scores (0, nonvisualization; 1, poor; 2, average; 3, good; 4, excellent) for five TFCC components, which were disc proper, triangular ligament, meniscus homologue, ulnotriquetral and ulnolunate ligament. Quantitative analysis included the signal-to-noise ratio (S/N) of the disc proper of TFCC, the lunate cartilage, the lunate bone and the contrast-noise-ratio (C/N) between articular cartilage and disc proper or bone marrow were measured. All structures show higher scores qualitatively on MR with microscopy coils than those with a C4 coil, and the difference was significant with the exception of the ulnolunate ligament. MR with microscopy coils showed significantly higher S/N values than those with a conventional surface coil (P<0.05 to P<0.001). T2*-weighted images using microscopy coils showed significantly higher cartilage-disc proper C/N and cartilage-bone marrow C/N (P<0.01 to P<0.001). On proton density-weighted images, the C/N between cartilage and disc proper with two microscopy coils was significantly higher (P<0.01) than that with a conventional coil. High-resolution MR images of the normal wrist using microscopy coils were superior to those using a conventional surface coil qualitatively and quantitatively. High-resolution MR imaging with a microscopy coil would be a promising method to diagnose TFCC lesions. (orig.)

  19. Coiled-Coil Irregularities and Instabilities in Group A Streptococcus M1 Are Required for Virulence

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Case; Zinkernagel, Annelies S.; Macheboeuf, Pauline; Cunningham, Madeleine W.; Nizet, Victor; Ghosh, Partho (UO-HSC); (UCSD)

    2008-07-21

    Antigenically variable M proteins are major virulence factors and immunogens of the human pathogen group A Streptococcus (GAS). Here, we report the -3 angstrom resolution structure of a GAS M1 fragment containing the regions responsible for eliciting type-specific, protective immunity and for binding fibrinogen, which promotes M1 proinflammatory and antiphagocytic functions. The structure revealed substantial irregularities and instabilities throughout the coiled coil of the M1 fragment. Similar structural irregularities occur in myosin and tropomyosin, explaining the patterns of cross-reactivity seen in autoimmune sequelae of GAS infection. Sequence idealization of a large segment of the M1 coiled coil enhanced stability but diminished fibrinogen binding, proinflammatory effects, and antibody cross-reactivity, whereas it left protective immunogenicity undiminished. Idealized M proteins appear to have promise as vaccine immunogens.

  20. Multiple-Coil, Pulse-Induction Metal Detector

    Science.gov (United States)

    Lesky, Edward S.; Reid, Alan M.; Bushong, Wilton E.; Dickey, Duane P.

    1988-01-01

    Multiple-head, pulse-induction metal detector scans area of 72 feet squared with combination of eight detector heads, each 3 ft. square. Head includes large primary coil inducing current in smaller secondary coils. Array of eight heads enables searcher to cover large area quickly. Pulses applied to primary coil, induced in secondary coils measured to determine whether metal present within range of detector head. Detector designed for recovery of Space Shuttle debris.

  1. Design and Testing of Coils for Pulsed Electromagnetic Forming

    OpenAIRE

    Golovashchenko, S.; Bessonov, N.; Davies, R

    2006-01-01

    Coil design influences the distribution of electromagnetic forces applied to both the blank and the coil. The required energy of the process is usually defined by deformation of the blank. However, the discharge also results in a significant amount of heat being generated and accumulating in the coil. Therefore, EMF process design involves working with three different problems: 1) propagation of an electromagnetic field through the coil-blank system and generation of pulsed electromagnetic pr...

  2. GBNV encoded movement protein (NSm) remodels ER network via C-terminal coiled coil domain

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Pratibha; Savithri, H.S., E-mail: bchss@biochem.iisc.ernet.in

    2015-08-15

    Plant viruses exploit the host machinery for targeting the viral genome–movement protein complex to plasmodesmata (PD). The mechanism by which the non-structural protein m (NSm) of Groundnut bud necrosis virus (GBNV) is targeted to PD was investigated using Agrobacterium mediated transient expression of NSm and its fusion proteins in Nicotiana benthamiana. GFP:NSm formed punctuate structures that colocalized with mCherry:plasmodesmata localized protein 1a (PDLP 1a) confirming that GBNV NSm localizes to PD. Unlike in other movement proteins, the C-terminal coiled coil domain of GBNV NSm was shown to be involved in the localization of NSm to PD, as deletion of this domain resulted in the cytoplasmic localization of NSm. Treatment with Brefeldin A demonstrated the role of ER in targeting GFP NSm to PD. Furthermore, mCherry:NSm co-localized with ER–GFP (endoplasmic reticulum targeting peptide (HDEL peptide fused with GFP). Co-expression of NSm with ER–GFP showed that the ER-network was transformed into vesicles indicating that NSm interacts with ER and remodels it. Mutations in the conserved hydrophobic region of NSm (residues 130–138) did not abolish the formation of vesicles. Additionally, the conserved prolines at positions 140 and 142 were found to be essential for targeting the vesicles to the cell membrane. Further, systematic deletion of amino acid residues from N- and C-terminus demonstrated that N-terminal 203 amino acids are dispensable for the vesicle formation. On the other hand, the C-terminal coiled coil domain when expressed alone could also form vesicles. These results suggest that GBNV NSm remodels the ER network by forming vesicles via its interaction through the C-terminal coiled coil domain. Interestingly, NSm interacts with NP in vitro and coexpression of these two proteins in planta resulted in the relocalization of NP to PD and this relocalization was abolished when the N-terminal unfolded region of NSm was deleted. Thus, the NSm

  3. Compressing DNA sequence databases with coil

    Directory of Open Access Journals (Sweden)

    Hendy Michael D

    2008-05-01

    Full Text Available Abstract Background Publicly available DNA sequence databases such as GenBank are large, and are growing at an exponential rate. The sheer volume of data being dealt with presents serious storage and data communications problems. Currently, sequence data is usually kept in large "flat files," which are then compressed using standard Lempel-Ziv (gzip compression – an approach which rarely achieves good compression ratios. While much research has been done on compressing individual DNA sequences, surprisingly little has focused on the compression of entire databases of such sequences. In this study we introduce the sequence database compression software coil. Results We have designed and implemented a portable software package, coil, for compressing and decompressing DNA sequence databases based on the idea of edit-tree coding. coil is geared towards achieving high compression ratios at the expense of execution time and memory usage during compression – the compression time represents a "one-off investment" whose cost is quickly amortised if the resulting compressed file is transmitted many times. Decompression requires little memory and is extremely fast. We demonstrate a 5% improvement in compression ratio over state-of-the-art general-purpose compression tools for a large GenBank database file containing Expressed Sequence Tag (EST data. Finally, coil can efficiently encode incremental additions to a sequence database. Conclusion coil presents a compelling alternative to conventional compression of flat files for the storage and distribution of DNA sequence databases having a narrow distribution of sequence lengths, such as EST data. Increasing compression levels for databases having a wide distribution of sequence lengths is a direction for future work.

  4. Improved coiled-coil design enhances interaction with Bcr-Abl and induces apoptosis.

    Science.gov (United States)

    Dixon, Andrew S; Miller, Geoffrey D; Bruno, Benjamin J; Constance, Jonathan E; Woessner, David W; Fidler, Trevor P; Robertson, James C; Cheatham, Thomas E; Lim, Carol S

    2012-01-01

    The oncoprotein Bcr-Abl drives aberrant downstream activity through trans-autophosphorylation of homo-oligomers in chronic myelogenous leukemia (CML).(1, 2) The formation of Bcr-Abl oligomers is achieved through the coiled-coil domain at the N-terminus of Bcr.(3, 4) We have previously reported a modified version of this coiled-coil domain, CCmut2, which exhibits disruption of Bcr-Abl oligomeric complexes and results in decreased proliferation of CML cells and induction of apoptosis.(5) A major contributing factor to these enhanced capabilities is the destabilization of the CCmut2 homodimers, increasing the availability to interact with and inhibit Bcr-Abl. Here, we included an additional mutation (K39E) that could in turn further destabilize the mutant homodimer. Incorporation of this modification into CCmut2 (C38A, S41R, L45D, E48R, Q60E) generated what we termed CCmut3, and resulted in further improvements in the binding properties with the wild-type coiled-coil domain representative of Bcr-Abl [corrected]. A separate construct containing one revert mutation, CCmut4, did not demonstrate improved oligomeric properties and indicated the importance of the L45D mutation. CCmut3 demonstrated improved oligomerization via a two-hybrid assay as well as through colocalization studies, in addition to showing similar biologic activity as CCmut2. The improved binding between CCmut3 and the Bcr-Abl coiled-coil may be used to redirect Bcr-Abl to alternative subcellular locations with interesting therapeutic implications.

  5. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif.

    Directory of Open Access Journals (Sweden)

    Nora Céspedes

    Full Text Available Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous to Plasmodium falciparum were identified in the P. vivax genome. The peptides identified in silico were chemically synthesized; circular dichroism studies indicated partial or high α-helical content. Antigenicity was evaluated using human sera samples from malaria-endemic areas of Colombia and Papua New Guinea. Eight of these fragments were selected and used to assess immunogenicity in BALB/c mice. ELISA assays indicated strong reactivity of serum samples from individuals residing in malaria-endemic regions and sera of immunized mice, with the α-helical coiled coil structures. In addition, ex vivo production of IFN-γ by murine mononuclear cells confirmed the immunogenicity of these structures and the presence of T-cell epitopes in the peptide sequences. Moreover, sera of mice immunized with four of the eight antigens recognized native proteins on blood-stage P. vivax parasites, and antigenic cross-reactivity with three of the peptides was observed when reacted with both the P. falciparum orthologous fragments and whole parasites. Results here point to the α-helical coiled coil peptides as possible P. vivax malaria vaccine candidates as were observed for P. falciparum. Fragments selected here warrant further study in humans and non-human primate models to assess their protective efficacy as single components or assembled as hybrid linear epitopes.

  6. Coiled-coil forming peptides for the induction of silver nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Božič Abram, Sabina [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Graduate School of Biomedicine, University of Ljubljana, Ljubljana 1000 (Slovenia); Aupič, Jana [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Doctoral Programme in Chemical Sciences, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ljubljana 1000 (Slovenia); Dražić, Goran [Laboratory for Materials Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Gradišar, Helena [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia); Jerala, Roman, E-mail: roman.jerala@ki.si [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia)

    2016-04-08

    Biopolymers with defined sequence patterns offer an attractive alternative for the formation of silver nanoparticle (AgNP). A set of coiled-coil dimer forming peptides was tested for their AgNP formation ability. Seventeen of those peptides mediated the formation of AgNPs in aqueous solution at neutral pH, while the formation of a coiled-coil dimer inhibited the nanoparticle generation. A QSAR regression model on the relationship between sequence and function suggests that in this peptide type the patterns KXQQ and KXEE are favorable, whereas Ala residues appear to have an inhibitory effect. UV–VIS spectra of the obtained nanoparticles gave a peak at around 420 nm, typical for AgNPs in the size range around 40 nm, which was confirmed by dynamic light scattering and transmission electron microscopy. Peptide-induced AgNPs exhibited good antibacterial activity, even after a 15 min contact time, while they had low toxicity to human cells at the same concentrations. These results show that our designed peptides generate AgNPs with antibacterial activity at mild conditions and might be used for antibacterial coatings. - Highlights: • 17 of the 30 tested coiled-coil forming peptides induce AgNP formation. • Coiled-coil dimer formation suppresses AgNP generation of individual peptides. • Size of the peptide-induced silver nanoparticles is around 40 nm. • QSAR analysis points to the importance of KXQQ and KXEE motifs for AgNP generation. • Peptide-induced silver nanoparticles exhibit antibacterial activity.

  7. Data-driven prediction and design of bZIP coiled-coil interactions.

    Science.gov (United States)

    Potapov, Vladimir; Kaplan, Jenifer B; Keating, Amy E

    2015-02-01

    Selective dimerization of the basic-region leucine-zipper (bZIP) transcription factors presents a vivid example of how a high degree of interaction specificity can be achieved within a family of structurally similar proteins. The coiled-coil motif that mediates homo- or hetero-dimerization of the bZIP proteins has been intensively studied, and a variety of methods have been proposed to predict these interactions from sequence data. In this work, we used a large quantitative set of 4,549 bZIP coiled-coil interactions to develop a predictive model that exploits knowledge of structurally conserved residue-residue interactions in the coiled-coil motif. Our model, which expresses interaction energies as a sum of interpretable residue-pair and triplet terms, achieves a correlation with experimental binding free energies of R = 0.68 and significantly out-performs other scoring functions. To use our model in protein design applications, we devised a strategy in which synthetic peptides are built by assembling 7-residue native-protein heptad modules into new combinations. An integer linear program was used to find the optimal combination of heptads to bind selectively to a target human bZIP coiled coil, but not to target paralogs. Using this approach, we designed peptides to interact with the bZIP domains from human JUN, XBP1, ATF4 and ATF5. Testing more than 132 candidate protein complexes using a fluorescence resonance energy transfer assay confirmed the formation of tight and selective heterodimers between the designed peptides and their targets. This approach can be used to make inhibitors of native proteins, or to develop novel peptides for applications in synthetic biology or nanotechnology.

  8. New Current Control Method of DC Power Supply for Magnetic Perturbation Coils on J-TEXT

    Institute of Scientific and Technical Information of China (English)

    ZENG Wubing; DING Yonghua; YI Bin; XU Hangyu; RAO Bo; ZHANG Ming; LIU Minghai

    2014-01-01

    In order to advance the research on suppressing tearing modes and driving plasma rotation,a DC power supply (PS) system has been developed for dynamic resonant magnetic perturbation (DRMP) coils and applied in the J-TEXT experiment.To enrich experimental phenomena in the J-TEXT tokamak,applying the circulating current four-quadrant operation mode in the DRMP DC PS system is proposed.By using the circulating current four-quadrant operation,DRMP coils can be smoothly controlled without the dead-time when the current polarity reverses.Essential circuit analysis,control optimization and simulation of desired scenarios have been performed for normal current.Relevant simulation and test results are also presented.

  9. 49 CFR 236.555 - Repaired or rewound receiver coil.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Repaired or rewound receiver coil. 236.555 Section 236.555 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... or rewound receiver coil. Receiver coil which has been repaired or rewound shall have the...

  10. The Roach muscle bundle and umbilical cord coiling

    NARCIS (Netherlands)

    de Laat, Monique W. M.; Nikkels, Peter G. J.; Franx, Arie; Visser, Gerard H. A.

    2007-01-01

    Objective: To determine if presence of the Roach muscle, a small muscle bundle tying just beside the umbilical artery, contributes to umbilical cord coiling. Methods: 251 umbilical cords were examined. The umbilical coiling index (UCI) was calculated as the number of coils divided by the cord length

  11. Transport of one SC coil through the village of Meyrin

    CERN Multimedia

    1956-01-01

    The energizing coils of the Synchro-cyclotron magnet were manufactured in Belgium before travelling to Basel in Switzerland by boat and continuing by road to Geneva. The first coil reached Geneva in December 1955, with the second following in early 1956. The coils were stored in a hangar at the Geneva airport before they were brought to CERN in May 1956.

  12. The training in epoxy-impregnated superconducting coils

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, H.; Bobrov, E.S.; Iwasa, Y.; Takaghi, T.; Tsukamoto, O.

    1985-03-01

    The authors have investigated the training of epoxy-impregnated superconducting coils. It has been observed that the boundary conditions at the coil ends have a crucial effect on shear-stress-induced epoxy cracks in the winding and consequently on the coil training. The results were quantified using acoustic emission data.

  13. Unconventional gradient coil designs in magnetic resonance imaging.

    Science.gov (United States)

    Zhu, Minhua; Xia, Ling; Liu, Feng

    2014-01-01

    In magnetic resonance imaging (MRI), the gradient coils are used to encode the spatial positions of protons by varying the magnetic field linearly across the imaging subject. With the latest development of MRI technique and new clinical and research applications, the gradient coil system requires increasingly innovative designs. In this paper, four unconventional gradient coil designs are reviewed: (1) local gradient coils; (2) new coil configurations with reduced peripheral nerve stimulation (PNS); (3) dedicated structures designed for hybrid systems (combining MRI with other medical devices); and (4) the full 3D coil designs. For the first type, the development of local gradient coils (mainly head coils) is discussed chronologically and divided into three stages: the "golden" stage in the 1990s, the "wane" stage in the 2000s, and the "revival" stage in the 2010s. For the second type, various designs for the reduction of PNS problems have been described, including local and whole-body gradient coil systems. For the third design, a dedicated gradient coil design for multi-modality combination is illustrated with an MRI-LINAC system. Finally, gradient systems with non-layered coil structure are described in the fourth design type. We hope that this review on unconventional gradient coil designs will be useful for the new development of MRI technology and emerging medical applications.

  14. Modeling Endovascular MRI Coil Coupling with Transmit RF Excitation

    Science.gov (United States)

    Venkateswaran, Madhav; Unal, Orhan; Hurley, Samuel; Samsonov, Alexey; Wang, Peng; Fain, Sean; Kurpad, Krishna

    2016-01-01

    Objective To model inductive coupling of endovascular coils with transmit RF excitation for selecting coils for MRI-guided interventions. Methods Independent and computationally efficient FEM models are developed for the endovascular coil, cable, transmit excitation and imaging domain. Electromagnetic and circuit solvers are coupled to simulate net B1+ fields and induced currents and voltages. Our models are validated using the Bloch Siegert B1+ mapping sequence for a series-tuned multimode coil, capable of tracking, wireless visualization and high resolution endovascular imaging. Results Validation shows good agreement at 24, 28 and 34 μT background RF excitation within experimental limitations. Quantitative coil performance metrics agree with simulation. A parametric study demonstrates trade off in coil performance metrics when varying number of coil turns. Tracking, imaging and wireless marker multimode coil features and their integration is demonstrated in a pig study. Conclusion Developed models for the multimode coil were successfully validated. Modeling for geometric optimization and coil selection serves as a precursor to time-consuming and expensive experiments. Specific applications demonstrated include parametric optimization, coil selection for a cardiac intervention and an animal imaging experiment. Significance Our modular, adaptable and computationally efficient modeling approach enables rapid comparison, selection and optimization of inductively-coupled coils for MRI-guided interventions. PMID:26960218

  15. A coiled-coil domain acts as a molecular ruler to regulate O-antigen chain length in lipopolysaccharide.

    Science.gov (United States)

    Hagelueken, Gregor; Clarke, Bradley R; Huang, Hexian; Tuukkanen, Anne; Danciu, Iulia; Svergun, Dmitri I; Hussain, Rohanah; Liu, Huanting; Whitfield, Chris; Naismith, James H

    2015-01-01

    Long-chain bacterial polysaccharides have important roles in pathogenicity. In Escherichia coli O9a, a model for ABC transporter-dependent polysaccharide assembly, a large extracellular carbohydrate with a narrow size distribution is polymerized from monosaccharides by a complex of two proteins, WbdA (polymerase) and WbdD (terminating protein). Combining crystallography and small-angle X-ray scattering, we found that the C-terminal domain of WbdD contains an extended coiled-coil that physically separates WbdA from the catalytic domain of WbdD. The effects of insertions and deletions in the coiled-coil region were analyzed in vivo, revealing that polymer size is controlled by varying the length of the coiled-coil domain. Thus, the coiled-coil domain of WbdD functions as a molecular ruler that, along with WbdA:WbdD stoichiometry, controls the chain length of a model bacterial polysaccharide.

  16. Tailored Presentation of Carbohydrates on a Coiled Coil-Based Scaffold for Asialoglycoprotein Receptor Targeting.

    Science.gov (United States)

    Zacco, Elsa; Hütter, Julia; Heier, Jason L; Mortier, Jérémie; Seeberger, Peter H; Lepenies, Bernd; Koksch, Beate

    2015-09-18

    The coiled-coil folding motif represents an ideal scaffold for the defined presentation of ligands due to the possibility of positioning them at specific distances along the axis. We created a coiled-coil glycopeptide library to characterize the distances between the carbohydrate-binding sites of the asialoglycoprotein receptors (ASGPR) on hepatocytes. The components of the glycopeptide library vary for the number of displayed ligands (galactose), their position on the peptide sequence, and the space between peptide backbone and carbohydrate. We determined the binding of the glycopeptides to the hepatocytes, and we established the optimal distance and orientation of the galactose moieties for interaction with the ASGPR using flow cytometry. We confirmed that the binding occurs through endocytosis mediated by ASGPR via inhibition studies with cytochalasin D; fluorescence microscopy studies display the uptake of the carrier peptides inside the cell. Thus, this study demonstrates that the coiled-coil motif can be used as reliable scaffold for the rational presentation of ligands.

  17. CENP-K and CENP-H may form coiled-coils in the kinetochores

    Institute of Scientific and Technical Information of China (English)

    QIU ShuLan; WANG JiaNing; YU Chuang; HE DaCheng

    2009-01-01

    Kinetochores are large proteinaceous structure on the surface of chromosomes' primary constriction during mitosis. They link chromosomes to spindle microtubules and also regulate the spindle assem-bly checkpoint, which is crucial for correct chromosome segregation in all eukaryotes. The better known core networks of kinetochores include the KMN network (K, KNL1; M, Mis12 complex; N, Ndc80 complex)and CCAN (constitutive centromere-associated network). However, the detailed molecular mechanism of the kinetochore protein network remains unclear. This study demonstrates that CENP-H and CENP-K form quite stable subcomplex by TAP (tandem affinity purification) with HEK 293 cells which express TAP-CENP-K, with the ratio of purified CENP-H and CENP-K being close to 1 : 1 even with high salt. Bioinformatic analysis suggests that CENP-H and CENP-K are enriched with coiled-coil regions. This implies that CENP-H and CENP-K form heterodimeric coiled-coils. Furthermore, the func-tional regions which form the complex are respectively located on their N- and C-terminals, but the association between the C-terminals is more complex. It is possible that this is the first identified het-erodimeric coiled-coils within the inner kinetochore, which is directly involved in the attachment be-tween kinetochores and the spindle microtubules.

  18. Coiled-Coil Proteins Facilitated the Functional Expansion of the Centrosome

    Science.gov (United States)

    Kuhn, Michael; Hyman, Anthony A.; Beyer, Andreas

    2014-01-01

    Repurposing existing proteins for new cellular functions is recognized as a main mechanism of evolutionary innovation, but its role in organelle evolution is unclear. Here, we explore the mechanisms that led to the evolution of the centrosome, an ancestral eukaryotic organelle that expanded its functional repertoire through the course of evolution. We developed a refined sequence alignment technique that is more sensitive to coiled coil proteins, which are abundant in the centrosome. For proteins with high coiled-coil content, our algorithm identified 17% more reciprocal best hits than BLAST. Analyzing 108 eukaryotic genomes, we traced the evolutionary history of centrosome proteins. In order to assess how these proteins formed the centrosome and adopted new functions, we computationally emulated evolution by iteratively removing the most recently evolved proteins from the centrosomal protein interaction network. Coiled-coil proteins that first appeared in the animal–fungi ancestor act as scaffolds and recruit ancestral eukaryotic proteins such as kinases and phosphatases to the centrosome. This process created a signaling hub that is crucial for multicellular development. Our results demonstrate how ancient proteins can be co-opted to different cellular localizations, thereby becoming involved in novel functions. PMID:24901223

  19. CENP-K and CENP-H may form coiled-coils in the kinetochores

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Kinetochores are large proteinaceous structure on the surface of chromosomes’ primary constriction during mitosis. They link chromosomes to spindle microtubules and also regulate the spindle assem- bly checkpoint, which is crucial for correct chromosome segregation in all eukaryotes. The better known core networks of kinetochores include the KMN network (K, KNL1; M, Mis12 complex; N, Ndc80 complex)and CCAN (constitutive centromere-associated network). However, the detailed molecular mechanism of the kinetochore protein network remains unclear. This study demonstrates that CENP-H and CENP-K form quite stable subcomplex by TAP (tandem affinity purification) with HEK 293 cells which express TAP-CENP-K, with the ratio of purified CENP-H and CENP-K being close to 1︰1 even with high salt. Bioinformatic analysis suggests that CENP-H and CENP-K are enriched with coiled-coil regions. This implies that CENP-H and CENP-K form heterodimeric coiled-coils. Furthermore, the func- tional regions which form the complex are respectively located on their N- and C-terminals, but the association between the C-terminals is more complex. It is possible that this is the first identified het- erodimeric coiled-coils within the inner kinetochore, which is directly involved in the attachment be- tween kinetochores and the spindle microtubules.

  20. Solutions for Safe Hot Coil Evacuation and Coil Handling in Case of Thick and High Strength Steel

    OpenAIRE

    Sieberer Stefan; Pichler Lukas; Hackl Manfred

    2016-01-01

    Currently hot rolling plants are entering the market segment for thick gauges and high strength steel grades where the elastic bending property of the strip leads to internal forces in the coil during coiling operation. The strip tends to open. Primetals is investigating several possibilities to facilitate safe coil evacuation and coil handling under spring-back conditions. The contribution includes finite element models of such mechanical solutions. Results of parameter variation and stabili...

  1. ACFA and IPAC announce accelerator prizes

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Steve Myers, CERN's Director for Accelerators and Technology. The Asian Committee for Future Accelerators (ACFA) has joined forces with the first International Particle Accelerator Conference, IPAC’10, to award prizes for outstanding work in the field of accelerators. The conference replaces the regional conferences of the Americas, Europe and Asia and will be hosted by the three regions on a rotational basis (see CERN Courier). The ACFA/IPAC’10 Prizes Selection Committee, chaired by Won Namkung of Pohang Accelerator Laboratory, decided on the prizes and the names of the winners at a meeting on 20 January. The awards will be made during IPAC’10, which will be held in Kyoto on 23-28 May. Jie Wei. (Courtesy Tsinghua University.) Steve Myers, Director for Accelerators and Technology at CERN, receives an Achievement Prize for Outstanding Work in the Accelerator Field with no Age Limit “for his numerous outstanding contributions to the design, construction, commissio...

  2. Studying rotational dynamics with a smartphone—accelerometer versus gyroscope

    Science.gov (United States)

    Braskén, Mats; Pörn, Ray

    2017-07-01

    The wide-spread availability of smartphones makes them a valuable addition to the measurement equipment of both the physics classroom and the instructional physics laboratory, encouraging an active interaction between measurements and modeling activities. Two useful sensors, available in most modern smartphones and tablets, are the 3-axis acceleration sensor and the 3-axis gyroscope. We explore the strengths and weaknesses of each type of sensor and use them to study the rotational dynamics of objects rotating about a fixed axis. Care has to be taken when interpreting acceleration sensor data, and in some cases the gyroscope will allow for rotational measurements not easily replicated using the acceleration sensor.

  3. Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging.

    Science.gov (United States)

    Chen, Xiao; Yang, Yang; Cai, Xiaoying; Auger, Daniel A; Meyer, Craig H; Salerno, Michael; Epstein, Frederick H

    2016-06-14

    Cine Displacement Encoding with Stimulated Echoes (DENSE) provides accurate quantitative imaging of cardiac mechanics with rapid displacement and strain analysis; however, image acquisition times are relatively long. Compressed sensing (CS) with parallel imaging (PI) can generally provide high-quality images recovered from data sampled below the Nyquist rate. The purposes of the present study were to develop CS-PI-accelerated acquisition and reconstruction methods for cine DENSE, to assess their accuracy for cardiac imaging using retrospective undersampling, and to demonstrate their feasibility for prospectively-accelerated 2D cine DENSE imaging in a single breathhold. An accelerated cine DENSE sequence with variable-density spiral k-space sampling and golden angle rotations through time was implemented. A CS method, Block LOw-rank Sparsity with Motion-guidance (BLOSM), was combined with sensitivity encoding (SENSE) for the reconstruction of under-sampled multi-coil spiral data. Seven healthy volunteers and 7 patients underwent 2D cine DENSE imaging with fully-sampled acquisitions (14-26 heartbeats in duration) and with prospectively rate-2 and rate-4 accelerated acquisitions (14 and 8 heartbeats in duration). Retrospectively- and prospectively-accelerated data were reconstructed using BLOSM-SENSE and SENSE. Image quality of retrospectively-undersampled data was quantified using the relative root mean square error (rRMSE). Myocardial displacement and circumferential strain were computed for functional assessment, and linear correlation and Bland-Altman analyses were used to compare accelerated acquisitions to fully-sampled reference datasets. For retrospectively-undersampled data, BLOSM-SENSE provided similar or lower rRMSE at rate-2 and lower rRMSE at rate-4 acceleration compared to SENSE (p cine DENSE provided good image quality and expected values of displacement and strain. BLOSM-SENSE-accelerated spiral cine DENSE imaging with 2D displacement encoding can be

  4. Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

    Science.gov (United States)

    Otani, Tomohiro; Ii, Satoshi; Shigematsu, Tomoyoshi; Fujinaka, Toshiyuki; Hirata, Masayuki; Ozaki, Tomohiko; Wada, Shigeo

    2016-07-21

    Coil embolization of cerebral aneurysms with inhomogeneous coil distribution leads to an incomplete occlusion of the aneurysm. However, the effects of this factor on the blood flow characteristics are still not fully understood. This study investigates the effects of coil configuration on the blood flow characteristics in a coil-embolized aneurysm using computational fluid dynamics (CFD) simulation. The blood flow analysis in the aneurysm with coil embolization was performed using a coil deployment (CD) model, in which the coil configuration was constructed using a physics-based simulation of the CD. In the CFD results, total flow momentum and kinetic energy in the aneurysm gradually decayed with increasing coil packing density (PD), regardless of the coil configuration attributed to deployment conditions. However, the total shear rate in the aneurysm was relatively high and the strength of the local shear flow varied based on the differences in coil configuration, even at adequate PDs used in clinical practice (20-25 %). Because the sufficient shear rate reduction is a well-known factor in the blood clot formation occluding the aneurysm inside, the present study gives useful insight into the effects of coil configuration on the treatment efficiency of coil embolization.

  5. Study on the performance improvement of the high temperature superconducting coil with several separated coils at the edges

    Science.gov (United States)

    Ishiguri, S.; Oka, T.; Fukui, S.; Ogawa, J.; Sato, T.

    2008-09-01

    In designing high temperature superconducting (HTS) coils, it is important to secure large magnetic fields and stored energy using shorter tape length. Thus, it is necessary to improve the transport current performance of the coils. The critical current and n-value of an HTS tape depend on magnetic fields and flux angles under constant temperature. Considering these dependencies, we established a model to analyze coil critical current. This model clarifies that relatively large electric fields are generated at the coil edges. This adversely affects the transport current performance. In this study, the coil edge is separated into several coils, keeping the total tape length constant. This increases the coil critical current, stored energy, central magnetic field, and also the coil volume, which contains vacancies created by the separation. To estimate coil performance, we calculated the stored energy density, whose denominator is the increased coil volume. This stored energy density reaches its maximum value when the number of the separated coils is eight. At this optimum separation, the central magnetic field increases by 13%, and the stored energy improves by 43%, compared to a rectangular coil wound with the same tape length.

  6. Structural attributes for the recognition of weak and anomalous regions in coiled-coils of myosins and other motor proteins

    Directory of Open Access Journals (Sweden)

    Sunitha Margaret S

    2012-09-01

    Full Text Available Abstract Background Coiled-coils are found in different proteins like transcription factors, myosin tail domain, tropomyosin, leucine zippers and kinesins. Analysis of various structures containing coiled-coils has revealed the importance of electrostatic and hydrophobic interactions. In such domains, regions of different strength of interactions need to be identified since they could be biologically relevant. Findings We have updated our coiled-coil validation webserver, now called COILCHECK+, where new features were added to efficiently identify the strength of interaction at the interface region and measure the density of charged residues and hydrophobic residues. We have examined charged residues and hydrophobic ladders, using a new algorithm called CHAHO, which is incorporated within COILCHECK + server. CHAHO permits the identification of spatial charged residue patches and the continuity of hydrophobic ladder which stabilizes and destabilizes the coiled-coil structure. Conclusions The availability of such computational tools should be useful to understand the importance of spatial clustering of charged residues and the continuity of hydrophobic residues at the interface region of coiled-coil dimers. COILCHECK + is a structure based tool to validate coiled-coil stability; it can be accessed at http://caps.ncbs.res.in/coilcheckplus.

  7. Subunit b-dimer of the Escherichia coli ATP synthase can form left-handed coiled-coils.

    Science.gov (United States)

    Wise, John G; Vogel, Pia D

    2008-06-01

    One remaining challenge to our understanding of the ATP synthase concerns the dimeric coiled-coil stator subunit b of bacterial synthases. The subunit b-dimer has been implicated in important protein interactions that appear necessary for energy conservation and that may be instrumental in energy conservation during rotary catalysis by the synthase. Understanding the stator structure and its interactions with the rest of the enzyme is crucial to the understanding of the overall catalytic mechanism. Controversy exists on whether subunit b adopts a classic left-handed or a presumed right-handed dimeric coiled-coil and whether or not staggered pairing between nonhomologous residues in the homodimer is required for intersubunit packing. In this study we generated molecular models of the Escherichia coli subunit b-dimer that were based on the well-established heptad-repeat packing exhibited by left-handed, dimeric coiled-coils by employing simulated annealing protocols with structural restraints collected from known structures. In addition, we attempted to create hypothetical right-handed coiled-coil models and left- and right-handed models with staggered packing in the coiled-coil domains. Our analyses suggest that the available structural and biochemical evidence for subunit b can be accommodated by classic left-handed, dimeric coiled-coil quaternary structures.

  8. The linear position tracking servo system using a linear voice-coil motor

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    More and more linear servo systems have been used in servo applications. Direct drive technology can greatly increase the bandwidth and the tracking accuracy. A position servo-system based on linear voice-coil motor was designed for one linear oscillation movement application. Besides the conventional position, speed and current control loops, the speed and acceleration feed-forward control of command position signal were also used. The experimental test proved the correctness of the design, and the system can track the given periodic sinnsoid position command signal of 15Hz with high accuracy. The linear voice-coil motor is very suitable for short stroke position tracking application with high dynamic response.

  9. Accelerated Unification

    OpenAIRE

    Arkani-Hamed, Nima; Cohen, Andrew; Georgi, Howard

    2001-01-01

    We construct four dimensional gauge theories in which the successful supersymmetric unification of gauge couplings is preserved but accelerated by N-fold replication of the MSSM gauge and Higgs structure. This results in a low unification scale of $10^{13/N}$ TeV.

  10. Voice Coil Actuator for Active Vibration Isolation in Microgravity

    Science.gov (United States)

    Brusa, E.; Carabelli, S.; Genta, G.; Maddaleno, F.; Silvagni, M.; Tonoli, A.

    2002-01-01

    Many microgravity experiments require very low levels of acceleration which cannot be achieved on the International Space Station due to the residual vibration. A vibration isolation system is then usually devised between the experiment and the space station to obtain the desired accelerations at the experiment level. The very low frequency threshold required by the isolation specifications makes passive solutions for the isolation difficult to implement. This is mainly due to the practical impossibility of achieving high values of compliance of the elastic suspension. Furthermore, the unavoidable connections of uncertain characteristics between the experiment and the space station makes the problem even more difficult to be addressed. Disturbance reduction can be performed by means of active vibration isolation, based on magnetic suspension technology acting both at rack and at scientific experiment levels. The stiffness and damping of the active suspension can be tuned by the control loop to minimise the acceleration of the payload. The mechatronic design of an active magnetic suspension for vibration isolation in microgravity has been performed by resorting to the so-called voice-coil configuration, after a preliminary trade-off analysis of the available magnetic actuators and materials. The optimisation of the actuator layout was developed with respect to the design airgap and force density (N/kg of actuator) and force resolution requirements, by demonstrating that the configuration based on Lorentz magnetic force is more suitable for the above application in terms of stability, bi- directionality of the actuation, cross coupling effects and linearity of the force. The aim of the design was the maximisation of the actuation force/mass ratio. The FEM analysis of the voice coil allowed to investigate the flux leakage and the cross coupling effects between the actuation forces along the three principal directions of the active device. A procedure for the numerical

  11. Design, simulation and evaluation of uniform magnetic field systems for head-free eye movement recordings with scleral search coils.

    Science.gov (United States)

    Eibenberger, Karin; Eibenberger, Bernhard; Rucci, Michele

    2016-08-01

    The precise measurement of eye movements is important for investigating vision, oculomotor control and vestibular function. The magnetic scleral search coil technique is one of the most precise measurement techniques for recording eye movements with very high spatial (≈ 1 arcmin) and temporal (>kHz) resolution. The technique is based on measuring voltage induced in a search coil through a large magnetic field. This search coil is embedded in a contact lens worn by a human subject. The measured voltage is in direct relationship to the orientation of the eye in space. This requires a magnetic field with a high homogeneity in the center, since otherwise the field inhomogeneity would give the false impression of a rotation of the eye due to a translational movement of the head. To circumvent this problem, a bite bar typically restricts head movement to a minimum. However, the need often emerges to precisely record eye movements under natural viewing conditions. To this end, one needs a uniform magnetic field that is uniform over a large area. In this paper, we present the numerical and finite element simulations of the magnetic flux density of different coil geometries that could be used for search coil recordings. Based on the results, we built a 2.2 × 2.2 × 2.2 meter coil frame with a set of 3 × 4 coils to generate a 3D magnetic field and compared the measured flux density with our simulation results. In agreement with simulation results, the system yields a highly uniform field enabling high-resolution recordings of eye movements.

  12. Exotic rotational correlations in quantum geometry

    Energy Technology Data Exchange (ETDEWEB)

    Hogan, Craig

    2017-05-01

    It is argued by extrapolation of general relativity and quantum mechanics that a classical inertial frame corresponds to a statistically defined observable that rotationally fluctuates due to Planck scale indeterminacy. Physical effects of exotic nonlocal rotational correlations on large scale field states are estimated. Their entanglement with the strong interaction vacuum is estimated to produce a universal, statistical centrifugal acceleration that resembles the observed cosmological constant.

  13. Planar quadrature coil design using shielded-loop resonators

    DEFF Research Database (Denmark)

    Stensgaard, A

    1997-01-01

    The shielded-loop resonator is known to have a low capacitive sample loss due to a perfect balancing. In this paper, it is demonstrated that shielded-loop technology also can be used to improve design of planar quadrature coils. Both a dual-loop circuit and especially a dual-mode circuit may...... benefit from use of shielded-loop resonators. Observations in measurements agree with theory for both a dual-loop coil and a dual-mode coil. The coils were designed for use as transmit/receive coil for 1H imaging and spectroscopy at 4.7 T in rat brain....

  14. Application of Microstructure Engineering in Steel Coil Cooling Process

    Institute of Scientific and Technical Information of China (English)

    LIU Zheng-dong; D Q Jin; I V Samarasekera; J K Brimacombe

    2005-01-01

    The coil cooling and its role in a hot strip mill were reviewed.A mathematical model was developed to describe and analyze the thermal history and its impact on precipitation phenomena during coil cooling for plain car bon,HSLA-V and HSLA-Nb steels.The predicted result of the thermal model was compared with that measured from industrial coil.The effect of cooling condition and coil dimension on the thermal history and final mechanical properties of the steel strip was examined.The coiling temperature and cooling rate have crucial influence on the precipitation strengthening.

  15. Superconducting coil system and methods of assembling the same

    Science.gov (United States)

    Rajput-Ghoshal, Renuka; Rochford, James H.; Ghoshal, Probir K.

    2016-01-19

    A superconducting magnet apparatus is provided. The superconducting magnet apparatus includes a power source configured to generate a current; a first switch coupled in parallel to the power source; a second switch coupled in series to the power source; a coil coupled in parallel to the first switch and the second switch; and a passive quench protection device coupled to the coil and configured to by-pass the current around the coil and to decouple the coil from the power source when the coil experiences a quench.

  16. Mechanical characteristics of the ATLAS B0 model coil

    CERN Document Server

    Foussat, A; Dudarev, A; Mayri, C; Miele, P; Sun, Z; ten Kate, H H J; Volpini, G

    2003-01-01

    The ATLAS B0 model coil has been tested at CERN to verify the design parameters of the Barrel Toroid coils (BT). The mechanical behavior of the B0 superconducting coil and its support structure is reported and compared with coil design calculations. The mechanical stresses and structural force levels during cooling down and excitation phases were monitored using strain gauges, position sensors and capacitive force transducers instrumentation. In the ATLAS magnet test facility, a magnetic mirror is used to reproduce the electromagnetic forces present in the BT coils, once these are assembled in toroid in the underground cavern in 2004. (8 refs).

  17. SSC (Superconducting Super Collider) dipole coil production tooling

    Energy Technology Data Exchange (ETDEWEB)

    Carson, J.A.; Barczak, E.J.; Bossert, R.C.; Brandt, J.S.; Smith, G.A.

    1989-03-01

    Superconducting Super Collider dipole coils must be produced to high precision to ensure uniform prestress and even conductor distribution within the collared coil assembly. Tooling is being prepared at Fermilab for the production of high precision 1M and 16.6M SSC dipole coils suitable for mass production. The design and construction methods builds on the Tevatron tooling and production experience. Details of the design and construction methods and measured coil uniformity of 1M coils will be presented. 4 refs., 10 figs.

  18. Random coil chemical shift for intrinsically disordered proteins

    DEFF Research Database (Denmark)

    Kjærgaard, Magnus; Brander, Søren; Poulsen, Flemming Martin

    2011-01-01

    . Temperature has a non-negligible effect on the (13)C random coil chemical shifts, so temperature coefficients are reported for the random coil chemical shifts to allow extrapolation to other temperatures. The pH dependence of the histidine random coil chemical shifts is investigated in a titration series......, which allows the accurate random coil chemical shifts to be obtained at any pH. By correcting the random coil chemical shifts for the effects of temperature and pH, systematic biases of the secondary chemical shifts are minimized, which will improve the reliability of detection of transient secondary...

  19. Spontaneous quenches of a high temperature superconducting pancake coil

    Energy Technology Data Exchange (ETDEWEB)

    Lue, J.W.; Lubell, M.S. [Oak Ridge National Lab., TN (United States); Aized, D.; Campbell, J.M.; Schwall, R.E. [American Superconductor Corp., Westborough, MA (United States)

    1995-09-01

    A double-pancake coil made of Bi-2223/Ag high temperature superconducting (HTS) tape was constructed with an embedded heater and graded conductors to study the stability and quench propagation in HTS coils. The experiments were performed with liquid nitrogen and gaseous helium cooling in temperatures ranging from 5 to 77 K. The coil was very stable, and no ``normal`` zone was sustained or propagated with local pulsed heating. However, spontaneous quenches of the cod were experienced. This was found to be the result of having the coil current higher than that of the lower I{sub c} sections of the coil for a long time. This quench process took minutes to develop--much longer than would be expected in a low temperature superconducting coil. The quench behaved more like a spreading and continuous heating of an increasingly larger partially resistive section of the coil than like a sequential ``normal`` front propagation.

  20. Fabrication of the superconducting coils for Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Risse, Konrad E-mail: konrad.risse@ipp.mpg.de; Rummel, Th.; Wegener, L.; Holzthuem, R.; Jaksic, N.; Kerl, F.; Sapper, J

    2003-09-01

    The Max Planck Institute of Plasma Physics is building up the stellarator fusion experiment Wendelstein 7-X (W7-X) at the branch institute in Greifswald. W7-X continues the line of stellarator experiments at IPP. To allow for steady state operation W7-X has a superconducting coil system with 50 non-planar and 20 planar coils. The coil system is grouped in five equal modules, each consisting of two mirror symmetric half modules. The half modules are assembled from five different non-planar coils, two planar coils and a sector of the coil support structure. All cryogenic parts are enclosed in a cryostat to protect them from ambient temperature. The magnet system was ordered from the European industry. The production of superconductor, winding packs and encasings are under way. The main focus of this contribution aims on the fabrication state of the coil system.

  1. Output beam analysis of high power COIL

    Institute of Scientific and Technical Information of China (English)

    Deli Yu(于德利); Fengting Sang(桑凤亭); Yuqi Jin(金玉奇); Yizhu Sun(孙以珠)

    2003-01-01

    As the output power of a chemical oxygen iodine laser (COIL) increases, the output laser beam instabilityappears as the far-field beam spot drift and deformation for the large Fresnel number unstable resonator.In order to interpret this phenomenon, an output beam mode simulation code was developed with the fastFourier transform method. The calculation results show that the presence of the nonuniform gain in COILproduces a skewed output intensity distribution, which causes the mirror tilt and bulge due to the thermalexpansion. With the output power of COIL increases, the mirror surfaces, especially the back surface ofthe scraper mirror, absorb more and more heat, which causes the drift and deformation of far field beamspot seriously. The initial misalignment direction is an important factor for the far field beam spot driftingand deformation.

  2. Theory of the quadrature elliptic birdcage coil.

    Science.gov (United States)

    Leifer, M C

    1997-11-01

    This paper presents the theory of the quadrature birdcage coil wound on an elliptic cylindrical former. A conformal transformation of the ellipse to a circular geometry is used to derive the optimal sampling of the continuous surface current distribution to produce uniform magnetic fields within an elliptic cylinder. The analysis is rigorous for ellipses of any aspect ratio and shows how to produce quadrature operation of the elliptic birdcage with a conventional hybrid combiner. Insight gained from the transformation is also used to analyze field homogeneity, find the optimal RF shield shape, and specify component values to produce the correct current distribution in practice. Measurements and images from a 16-leg elliptic birdcage coil at both low and high frequencies show good quadrature performance, homogeneity, and sensitivity.

  3. Magnetically Damped Furnace Bitter Magnet Coil 1

    Science.gov (United States)

    Bird, M. D.

    1997-01-01

    A magnet has been built by the National High Magnetic Field Laboratory for NASA on a cost reimbursement contract. The magnet is intended to demonstrate the technology and feasibility of building a magnet for space based crystal growth. A Bitter magnet (named after Francis Bitter, its inventor) was built consisting of four split coils electrically in series and hydraulically in parallel. The coils are housed in a steel vessel to reduce the fringe field and provide some on-axis field enhancement. The steel was nickel plated and Teflon coated to minimize interaction with the water cooling system. The magnet provides 0.14 T in a 184 mm bore with 3 kW of power.

  4. DC SQUIDS with planar input coils

    Energy Technology Data Exchange (ETDEWEB)

    Pegrum, C.M.; Donaldson, G.B.; Hutson, D.; Tugwell, A.

    1985-03-01

    We describe the key parts of our recent work to develop a planar thin-film DC SQUID with a closely-coupled spiral input coil. Our aim has been to make a device that is superior to present RF SQUID sensors in terms of sensitivity and long-term reliability. To be compatible with an RF SQUID the inductance of the input coils must be relatively large, typically 2..mu..H, and the input noise current in the white noise region should be below 10pA Hz /SUP -1/2/ . A low level of 1/f noise is also necessary for many applications and should be achieved without the use of complex noisecancelling circuitry. Our devices meet these criteria. We include a description of work on window and edge junction fabrication using ion beam cleaning, thermal oxidation and RF plasma processing.

  5. Research and Application of Voice Coil Motor%音圈电机研究及应用综述

    Institute of Scientific and Technical Information of China (English)

    兴连国; 周惠兴; 侯书林; 曹荣敏

    2011-01-01

    Voice coil motor is a special type of linear motor, which is similar to the voice coil of loudhailer in terms of working principle. Voice coil motor is a transmission-free device. The electrical energy can be directly converted into mechanical energy. Voice coil motor is characterized by being of high acceleration, high speed, smooth force, fast response, small-volume, light-weigh. The theoretical basis for the design and selection was provided in this paper. Working principle, topology form, design methods, control algorithms and heat balance of voice coil motor were introduced in detail. Design and calculation methods of voice coil motor were given. Finally the application and recent studies of voice coil motor were presented.%音圈电机是特种直线电机,是一种将电能直接转化为直线或者圆弧运动机械能而不需要任何中间转换机构的传动装置,其工作原理与扬声器的音圈类似.音圈电机具有体积小、重量轻、高加速度、高速度、快速响应、推力均匀等优良性能.介绍了音圈电机的设计与选用的理论基础,并阐述了音圈电机的技术工作原理、结构形式、设计方案、控制方法和热平衡分析.给出了音圈电机的设计计算方法,并对音圈电机的应用场合进行了详细介绍.

  6. Acute lung injury following refrigeration coil deicing.

    Science.gov (United States)

    McKeown, Nathanael J; Burton, Brent T

    2012-03-01

    We report a case of a worker who developed ALI requiring mechanical ventilatory support after attempting to melt ice condensate by applying the flame of an oxy-acetylene torch to refrigeration coils charged with a halocarbon refrigerant in a closed environment. A discussion of possible etiologies are discussed, including phosgene, carbonyl fluoride, and nitrogen oxides. Primary prevention with adequate respiratory protection is recommended whenever deicing is performed in a closed space environment.

  7. A polymer driveshaft for use in orbital and rotational atherectomy

    Science.gov (United States)

    Grothe, Preston Lee

    Driveshafts used in atherectomy medical devices are often comprised of coiled or braided metal wires. These constructions are designed to tolerate delivery through tortuous vessels and can endure high speed rotation used during activation of the atherectomy treatment. This research investigated polymer driveshaft designs, which were comprised of polymer inner and outer layers, and coiled or braided stainless steel wires. The polymer driveshaft materials included polyimide, nylon 12, and polytetrafluoroethylene (PTFE). Mechanical testing of polymer driveshafts was conducted to determine material response in bending, tension, compression, and torsion. The polymer driveshaft test results were then compared with current coiled metal wire driveshaft constructions. The investigation identified polymer driveshaft options that could feasibly work in an atherectomy application.

  8. Particle Accelerators in China

    Science.gov (United States)

    Zhang, Chuang; Fang, Shouxian

    As the special machines that can accelerate charged particle beams to high energy by using electromagnetic fields, particle accelerators have been widely applied in scientific research and various areas of society. The development of particle accelerators in China started in the early 1950s. After a brief review of the history of accelerators, this article describes in the following sections: particle colliders, heavy-ion accelerators, high-intensity proton accelerators, accelerator-based light sources, pulsed power accelerators, small scale accelerators, accelerators for applications, accelerator technology development and advanced accelerator concepts. The prospects of particle accelerators in China are also presented.

  9. ELM mitigation via rotating resonant magnetic perturbations on MAST

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, A.J., E-mail: andrew.thornton@ccfe.ac.uk [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Kirk, A. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Cahyna, P. [Institute of Plasma Physics AS CR v.v.i, Prague (Czech Republic); Chapman, I.T.; Fishpool, G.; Harrison, J.R.; Liu, Y.Q. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Kripner, L.; Peterka, M. [Institute of Plasma Physics AS CR v.v.i, Prague (Czech Republic)

    2015-08-15

    The application of resonant magnetic perturbations (RMPs) produces splitting of the divertor strike point due to the interaction of the RMP field and the plasma field. The application of a rotating RMP field causes the strike point splitting to rotate, distributing the particle and heat flux evenly over the divertor. The RMP coils in MAST have been used to generate a rotating perturbation with a toroidal mode number n = 3. The ELM frequency is doubled with the application of the RMP rotating field, whilst maintaining the H mode. During mitigation, the ELM peak heat flux is seen to be reduced by 50% for a halving in the ELM energy and motion of the strike point, consistent with the rotation of the applied RMP field, is seen using high spatial resolution (1.5 mm at the target) heat flux profiles measured using infrared (IR) thermography.

  10. High-resolution MR imaging of the normal rotator cuff.

    Science.gov (United States)

    Middleton, W D; Kneeland, J B; Carrera, G F; Cates, J D; Kellman, G M; Campagna, N G; Jesmanowicz, A; Froncisz, W; Hyde, J S

    1987-03-01

    The shoulders of six normal volunteers were imaged with high-resolution MR in the axial, sagittal, and coronal planes. An angled pair of counter-rotating current loop-gap resonators designed specifically for the shoulder was used as a local coil. All images were compared with corresponding cryomicrotome sections from cadaver shoulders. The rotator cuff was analyzed in detail. It appeared as a complex, heterogeneous band to tissue superficial to the humeral head. The areas of low signal intensity corresponded to the central tendons of the four rotator cuff muscles. These tendons could be distinguished from each other as well as from the intervening components of the cuff, which have a moderate intensity. We concluded that MR is capable of imaging the normal rotator cuff and of separating the various components. This may allow for improved precision in the diagnosis of rotator cuff disorders.

  11. ELM mitigation via rotating resonant magnetic perturbations on MAST

    CERN Document Server

    Thornton, A J; Cahyna, P; Chapman, I T; Fishpool, G; Harrison, J R; Liu, Y Q; Kripner, L; Peterka, M

    2014-01-01

    The application of resonant magnetic perturbations (RMPs) produces splitting of the divertor strike point due to the interaction of the RMP field and the plasma field. The application of a rotating RMP field causes the strike point splitting to rotate, distributing the particle and heat flux evenly over the divertor. The RMP coils in MAST have been used to generate a rotating perturbation with a toroidal mode number n=3. The ELM frequency is doubled with the application of the RMP rotating field, whilst maintaining the H mode. During mitigation, the ELM peak heat flux is seen to be reduced by 50% for a halving in the ELM energy and motion of the strike point, consistent with the rotation of the applied RMP field, is seen using high spatial resolution (1.5mm at the target) heat flux profiles measured using infrared (IR) thermography.

  12. Mechanical Resonances of Helically Coiled Carbon Nanowires

    Science.gov (United States)

    Saini, D.; Behlow, H.; Podila, R.; Dickel, D.; Pillai, B.; Skove, M. J.; Serkiz, S. M.; Rao, A. M.

    2014-07-01

    Despite their wide spread applications, the mechanical behavior of helically coiled structures has evaded an accurate understanding at any length scale (nano to macro) mainly due to their geometrical complexity. The advent of helically coiled micro/nanoscale structures in nano-robotics, nano-inductors, and impact protection coatings has necessitated the development of new methodologies for determining their shear and tensile properties. Accordingly, we developed a synergistic protocol which (i) integrates analytical, numerical (i.e., finite element using COMSOL®) and experimental (harmonic detection of resonance; HDR) methods to obtain an empirically validated closed form expression for the shear modulus and resonance frequency of a singly clamped helically coiled carbon nanowire (HCNW), and (ii) circumvents the need for solving 12th order differential equations. From the experimental standpoint, a visual detection of resonances (using in situ scanning electron microscopy) combined with HDR revealed intriguing non-planar resonance modes at much lower driving forces relative to those needed for linear carbon nanotube cantilevers. Interestingly, despite the presence of mechanical and geometrical nonlinearities in the HCNW resonance behavior the ratio of the first two transverse modes f2/f1 was found to be similar to the ratio predicted by the Euler-Bernoulli theorem for linear cantilevers.

  13. Numerical dosimetry of transcranial magnetic stimulation coils

    Science.gov (United States)

    Crowther, Lawrence; Hadimani, Ravi; Jiles, David

    2014-03-01

    Transcranial magnetic stimulation (TMS) is a non-invasive neuromodulation technique capable of stimulating neurons by means of electromagnetic induction. TMS can be used to map brain function and shows promise for the diagnosis and treatment of neurological and psychiatric disorders. Calculation of fields induced in the brain are necessary to accurately identify stimulated neural tissue during TMS. This allows the development of novel TMS coil designs capable of stimulating deeper brain regions and increasing the localization of stimulation that can be achieved. We have performed numerical calculations of magnetic and electric field with high-resolution anatomically realistic human head models to find these stimulated brain regions for a variety of proposed TMS coil designs. The realistic head models contain heterogeneous tissue structures and electrical conductivities, yielding superior results to those obtained from the simplified homogeneous head models that are commonly employed. The attenuation of electric field as a function of depth in the brain and the localization of stimulating field have been methodically investigated. In addition to providing a quantitative comparison of different TMS coil designs the variation of induced field between subjects has been investigated. We also show the differences in induced fields between adult, adolescent and child head models to preemptively identify potential safety issues in the application of pediatric TMS.

  14. The coiling of electrified liquid jets

    Science.gov (United States)

    Rivero Rodriguez, Javier; Pérez-Saborid, Miguel

    2013-11-01

    We have carried out a numerical study of the coiling regime which takes place when an electrified liquid jet issuing from an orifice drilled in a metal plate electrode reaches the counter electrode. Based on the slenderness assumption, we have derived the set of one-dimensional dynamical equations by averaging the underlying balance laws over the jet cross sections (Cosserat rod model). Therefore, our equations and boundary conditions are related to those obtained by N.M. Ribe (Ann. Rev Fluid Mech., 2012) for the coiling of liquid ropes, but including electrostatic effects. In a first approach, we have simplified the electrical terms entering the problem by assuming a constant external electric field between electrodes, and that the charges are convected by the jet surface interacting electrostatically with each other via the local interaction approximation (Yarin et al., 2001). We have numerically investigated the problem in order to analize how the coiling regime depends on the dimensionless parameters of the problem, i.e., the Reynolds number, the electrical Bond number and the capillary number. In particular, we have found that both the displacement of the centerline of the jet and its cross-sectional stretching greatly depend on the electrostatic effects. Thanks to the MINECO (Spain) for partial support under grant DPI2010-20450-C03-02.

  15. MUON ACCELERATION

    Energy Technology Data Exchange (ETDEWEB)

    BERG,S.J.

    2003-11-18

    One of the major motivations driving recent interest in FFAGs is their use for the cost-effective acceleration of muons. This paper summarizes the progress in this area that was achieved leading up to and at the FFAG workshop at KEK from July 7-12, 2003. Much of the relevant background and references are also given here, to give a context to the progress we have made.

  16. Rehabilitation after Rotator Cuff Repair.

    Science.gov (United States)

    Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos

    2017-01-01

    Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.

  17. Development of superconducting magnetic bearing with superconducting coil and bulk superconductor for flywheel energy storage system

    Science.gov (United States)

    Arai, Y.; Seino, H.; Yoshizawa, K.; Nagashima, K.

    2013-11-01

    We have been developing superconducting magnetic bearing for flywheel energy storage system to be applied to the railway system. The bearing consists of a superconducting coil as a stator and bulk superconductors as a rotor. A flywheel disk connected to the bulk superconductors is suspended contactless by superconducting magnetic bearings (SMBs). We have manufactured a small scale device equipped with the SMB. The flywheel was rotated contactless over 2000 rpm which was a frequency between its rigid body mode and elastic mode. The feasibility of this SMB structure was demonstrated.

  18. Laser acceleration

    Science.gov (United States)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  19. Finite Element Analyses and Instrumentation Layout for Single Coil Testing of TF Coils in HT-7U

    Institute of Scientific and Technical Information of China (English)

    陈文革; 翁佩德

    2003-01-01

    The HT-7U tokamak is a magnetically-confined full superconducting fusion device,consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF)coils. These coils are wound with cable-in-conductor (CICC) which is based on UNK NbTi wiresmade in Russian [1]. A single D-shaped toroidal field magnet coil will be tested for large andexpensive magnets systems before assembling them in the toroidal configuration. This paperdescribes the layout of the instrumentation for a superconducting test facility based on the resultsof a finite element modeling of the single coil of toroidal magnetic field (TF) coils in HT-7Utokamak device. At the same time, the design of coil support structure in the test facility isparticularly discussed in some detail.

  20. Design of a Microwave Assisted Discharge Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.

    2010-01-01

    The design and construction of a thruster that employs electrodeless plasma preionization and pulsed inductive acceleration is described. Preionization is achieved through an electron cyclotron resonance discharge that produces a weakly-ionized plasma at the face of a conical theta pinch-shaped inductive coil. The presence of the preionized plasma allows for current sheet formation at lower discharge voltages than those employed in other pulsed inductive accelerators that do not employ preionization. The location of the electron cyclotron resonance discharge is controlled through the design of the applied magnetic field in the thruster. Finite element analysis shows that there is an arrangement of permanent magnets that yields a small volume of resonant magnetic field at the coil face. Preionization in the resonant zone leads to current sheet formation at the coil face, which minimizes the initial inductance of the pulse circuit and maximizes the potential electrical efficiency of the accelerator. A magnet assembly was constructed around an inductive coil to provide structural support to the selected arrangement of neodymium magnets. Measured values of the resulting magnetic field compare favorably with the finite element model.

  1. Influence of Rotation of Steady Speed Table on Orientation Stability of Servo Table in Linear Accelerating table%线加速度台中稳速台转动对随动台定位稳定性的影响

    Institute of Scientific and Technical Information of China (English)

    高扬; 唐声权; 张新磊; 吴华阳

    2012-01-01

    针对线加速度台用于加速度计测试时,随动台定位受稳速台旋转干扰的现象进行了分析,提出被测设备质量要在负载允许范围内,使设备质心尽可能靠近随动台回转中心,并对其配平,以使稳速台转动带来的干扰力矩大大降低,保证测试中随动台的定位准确度及稳定性.%The phenomenon that servo table positioning interfered by steady speed table rotating was analysis among linear accelerating table on testing accuracy of accelerometer. The weight of equipment is brought forward to be within the allowable range, as far as possible to make the centroid of equipment close to the servo table rotary center, and use other loads to balance it if required. It has reduced disturbance torque caused by rotation of steady speed table and improved the stability of the test axis positioning, and ensured positioning accuracy to fulfil the test.

  2. Work and energy in rotating systems

    CERN Document Server

    Manjarres, Diego A; Diaz, Rodolfo A

    2012-01-01

    Literature analyzes the way in which Newton's second law can be used when non-inertial rotating systems are used. However, the treatment of the work and energy theorem in rotating systems is not considered in textbooks. In this paper, we show that the work and energy theorem can still be applied to a closed system of particles in a rotating system, as long as the work of fictitious forces is properly included in the formalism. The coriolis force does not contribute to the work coming from fictitious forces. It worths remarking that real forces that do not do work in an inertial reference frame can do work in the rotating reference frame and viceversa. The combined effects of acceleration of the origin and rotation of the non-inertial system are also studied.

  3. Applications of rotary jetting tool with coiled tubing offshore Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Ricardo; Almeida, Victor; Mendez, Alfredo; Dean, Greg [BJ Services do Brasil Ltda., RJ (Brazil)

    2004-07-01

    It is well known that offshore operators are continuously looking for alternatives to reduce rig time, especially when it comes to work over operations due to high costs. The introduction of a Rotary Jetting Tool (RJT) in conjunction with coiled tubing was successfully tested and proved to be a better alternative not only because of its efficiency but also due to a reduction in the time of intervention operations. The RJT was created to remove scales and well obstructions by utilization of stress-cycling jetting. Stress cycling is a jetting mechanism that consists of pressuring and energizing fluid against a material. This mechanism breaks scales or obstructions and vibrates proppants in gravel pack completions. The RJT is composed of turbines that generate spinning and magnets that control the rotation. Most fluids used in the oil industry for remedial operations are compatible with this tool, hence its wide range of applications. This paper will present case histories that vary from hydrate and scale removal, and matrix stimulations including cleaning of gravel pack completions. The usage of this RJT has demonstrated effectiveness as a new alternative to improve well production and reduce rig time when compared to other methods commonly used in the area. (author)

  4. A robotic finger driven by twisted and coiled polymer actuator

    Science.gov (United States)

    Cho, Kyeong Ho; Song, Min Geun; Jung, Hosang; Park, Jungwoo; Moon, Hyungpil; Koo, Ja Choon; Nam, Jae-Do; Choi, Hyouk Ryeol

    2016-04-01

    Previous studies reported that a twisted and coiled polymer actuator (TCA) generates strong force and large stroke by heating. Nylon 6,6 is known to be the most suitable polymer material for TCA because it has high thermal expansion ratio, high softening point and high toughness which is able to sustain gigantic twisting. In order to find the optimal structure of TCA fabricated with silver-coated nylon sewing threads, an equipment for twist-insertion (structuralization), composed of single DC motor, a slider fabricated by 3D printer and a body frame, is developed. It can measure the behaviors of TCAs as well as fabricate TCAs with desired characteristics by structuralizing fibers with controlled rotation per minutes (RPM) and turns. Comparing performances of diverse structures of TCAs, the optimal structure for TCA is found. For the verification of the availability of the optimal TCA, a TCA-driven biomimetic finger is developed. Finally, we successfully demonstrate the flexion/extension of the finger by using the actuation of TCAs.

  5. High-Intensity Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2011-12-27

    Analysis is presented for an eight-cavity proton cyclotron accelerator that could have advantages as compared with other accelerators because of its potentially high acceleration gradient. The high gradient is possible since protons orbit in a sequence of TE111 rotating mode cavities of equally diminishing frequencies with path lengths during acceleration that greatly exceed the cavity lengths. As the cavities operate at sequential harmonics of a basic repetition frequency, phase synchronism can be maintained over a relatively wide injection phase window without undue beam emittance growth. It is shown that use of radial vanes can allow cavity designs with significantly smaller radii, as compared with simple cylindrical cavities. Preliminary beam transport studies show that acceptable extraction and focusing of a proton beam after cyclic motion in this accelerator should be possible. Progress is also reported on design and tests of a four-cavity electron counterpart accelerator for experiments to study effects on beam quality arising from variations injection phase window width. This device is powered by four 500-MW pulsed amplifiers at 1500, 1800, 2100, and 2400 MHz that provide phase synchronous outputs, since they are driven from a with harmonics derived from a phase-locked 300 MHz source.

  6. Transcranial Magnetic Stimulation-coil design with improved focality

    Science.gov (United States)

    Rastogi, P.; Lee, E. G.; Hadimani, R. L.; Jiles, D. C.

    2017-05-01

    Transcranial Magnetic Stimulation (TMS) is a technique for neuromodulation that can be used as a non-invasive therapy for various neurological disorders. In TMS, a time varying magnetic field generated from an electromagnetic coil placed on the scalp is used to induce an electric field inside the brain. TMS coil geometry plays an important role in determining the focality and depth of penetration of the induced electric field responsible for stimulation. Clinicians and basic scientists are interested in stimulating a localized area of the brain, while minimizing the stimulation of surrounding neural networks. In this paper, a novel coil has been proposed, namely Quadruple Butterfly Coil (QBC) with an improved focality over the commercial Figure-8 coil. Finite element simulations were conducted with both the QBC and the conventional Figure-8 coil. The two coil's stimulation profiles were assessed with 50 anatomically realistic MRI derived head models. The coils were positioned on the vertex and the scalp over the dorsolateral prefrontal cortex to stimulate the brain. Computer modeling of the coils has been done to determine the parameters of interest-volume of stimulation, maximum electric field, location of maximum electric field and area of stimulation across all 50 head models for both coils.

  7. Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Dinc, Hasan [Karadeniz Technical University, Department of Radiology, Faculty of Medicine, Trabzon (Turkey); KTU Farabi Hospital, Department of Radiology, Trabzon (Turkey); Kuzeyli, Kayhan [Karadeniz Technical University, Department of Neurosurgery, Faculty of Medicine, Trabzon (Turkey); Kosucu, Polat; Sari, Ahmet [Karadeniz Technical University, Department of Radiology, Faculty of Medicine, Trabzon (Turkey); Cekirge, Saruhan [Hacettepe University, Department of Radiology, Faculty of Medicine, Ankara (Turkey)

    2006-04-15

    One of the feared complications during detachable coil embolization of cerebral aneurysms is herniation of a coil loop into the parent artery. Although coil protrusion of one or two loops into the parent vessel may not cause adverse events and in some instances can be ignored, the authors believe that coil retrieval is indicated if a free end is seen pulsating along the blood flow stream to prevent migration of the entire coil mass. In one patient, a microballoon was inflated across the neck of the aneurysm during retrieval of a herniated coil to prevent further coil herniation from the aneurysm sac. We present two cases in which prolapsed coils were successfully retrieved either using a microsnare and balloon combination or a microsnare alone. This report focuses on the efficacy of the Amplatz microsnare for such retrievals and the circumstances in which a herniated coil needs to be retrieved. We report two cases in which embolization coils partially migrated into the parent artery during endovascular treatment of cerebral aneurysm and were retrieved using the Amplatz Nitinol microsnare. (orig.)

  8. Accelerators and the Accelerator Community

    Energy Technology Data Exchange (ETDEWEB)

    Malamud, Ernest; Sessler, Andrew

    2008-06-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process.

  9. A Novel Permanent Magnetic Angular Acceleration Sensor

    Directory of Open Access Journals (Sweden)

    Hao Zhao

    2015-07-01

    Full Text Available Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s−2. Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

  10. A Novel Permanent Magnetic Angular Acceleration Sensor.

    Science.gov (United States)

    Zhao, Hao; Feng, Hao

    2015-07-03

    Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s(-2)). Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

  11. Hadron accelerators for radiotherapy

    Science.gov (United States)

    Owen, Hywel; MacKay, Ranald; Peach, Ken; Smith, Susan

    2014-04-01

    Over the last twenty years the treatment of cancer with protons and light nuclei such as carbon ions has moved from being the preserve of research laboratories into widespread clinical use. A number of choices now exist for the creation and delivery of these particles, key amongst these being the adoption of pencil beam scanning using a rotating gantry; attention is now being given to what technologies will enable cheaper and more effective treatment in the future. In this article the physics and engineering used in these hadron therapy facilities is presented, and the research areas likely to lead to substantive improvements. The wider use of superconducting magnets is an emerging trend, whilst further ahead novel high-gradient acceleration techniques may enable much smaller treatment systems. Imaging techniques to improve the accuracy of treatment plans must also be developed hand-in-hand with future sources of particles, a notable example of which is proton computed tomography.

  12. Tests of Insulation Systems for Nb3SN Wind and React Coils

    Science.gov (United States)

    Bossert, R.; Ambrosio, G.; Andreev, N.; Whitson, G.; Zlobin, A.

    2008-03-01

    Tests were performed to assess the viability of several cable insulation systems for use in Nb3Sn accelerator magnets. Insulated stacks of cables were subjected to reaction cycles commonly used for Nb3Sn coils. After reaction and epoxy impregnation, current leakage between turns was measured at pressures up to 180 MPa and turn-to-turn potentials up to 500 V. Systems consisting of S-2 glass, ceramic fiber, and E-glass were tested. Several methods of applying the insulation were incorporated, including sleeves and various spiral wrapped configurations. Methods of sample preparation and testing are described and results are reported.

  13. Discrete Differential Geometry Applied to the Coil-End Design of Superconducting Magnets

    CERN Document Server

    Auchmann, B; Schwerg, N

    2007-01-01

    Coil-end design for superconducting accelerator magnets, based on the continuous strip theory of differential geometry, has been introduced by Cook in 1991. A similar method has later been coupled to numerical field calculation and used in an integrated design process for LHC magnets within the CERN field computation program ROXIE. In this paper we present a discrete analog on to the continuous theory of strips. Its inherent simplicity enhances the computational performance, while reproducing the accuracy of the continuous model. The method has been applied to the design

  14. Rotator cuff exercises

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000357.htm Rotator cuff exercises To use the sharing features on this ... gov/pubmed/25560729 . Read More Frozen shoulder Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT scan Shoulder ...

  15. Research on automatic non-destructive testing system of oil coiled tubing

    Science.gov (United States)

    Guo, Rong; Qiu, Wenbin; Wang, Yuhui; Ren, Jianguang

    2010-10-01

    A method using ultrasonic devices for on-line measurement of oil coiled tubing was proposed. The principle of ultrasonic testing was analyzed. Then, the structure of the system consisting of mechanical system, coupling system, measuring system, control system and system software was determinated. Based on the analysis of technology requirement, measuring technique in which the coiled tubing did not rotate and the probe was static was chosen. The ultrasonic testing probes were triggered in turn. After signal sampling, digital filtering and A / D conversion signal processing, the received echo signals were sent to computer. Through analyzing and accounting, the test results were obtained. Based on VC++.net, A-type ultrasonic and C-type ultrasonic display software and the inspection data processing software were developed. Using Windows programming technology, the software structure and function library were totally open. Therefore, secondary development can be carried out conveniently. Based on the experimental studies, coiled tubing's ultrasonic testing system is developed. The testing results show that the system has specific advantages such as high-adaptation, highefficiency, high- stability, high reliability and can meet the need of the users. The ultrasonic testing technologies proposed in this paper can be applied extensively to other tubes.

  16. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  17. Impact accelerations

    Science.gov (United States)

    Vongierke, H. E.; Brinkley, J. W.

    1975-01-01

    The degree to which impact acceleration is an important factor in space flight environments depends primarily upon the technology of capsule landing deceleration and the weight permissible for the associated hardware: parachutes or deceleration rockets, inflatable air bags, or other impact attenuation systems. The problem most specific to space medicine is the potential change of impact tolerance due to reduced bone mass and muscle strength caused by prolonged weightlessness and physical inactivity. Impact hazards, tolerance limits, and human impact tolerance related to space missions are described.

  18. Modeling Rotating Turbulent Flows with the Body Force Potential Model.

    Science.gov (United States)

    Bhattacharya, Amitabh; Perot, Blair

    2000-11-01

    Like a Reynolds Stress Transport equation model, the turbulent potential model has an explicit Coriolis acceleration term that appears in the model that accounts for rotation effects. In this work the additional secondary effects that system rotation has on the dissipation rate, return-to-isotropy, and fast pressure strain terms are also included in the model. The resulting model is tested in the context of rotating isotropic turbulence, rotating homogeneous shear flow, rotating channel flow, and swirling pipe flow. Many of the model changes are applicable to Reynolds stress transport equation models. All model modifications are frame indifferent.

  19. The heterotrimeric laminin coiled-coil domain exerts anti-adhesive effects and induces a pro-invasive phenotype.

    Directory of Open Access Journals (Sweden)

    Patricia Santos-Valle

    Full Text Available Laminins are large heterotrimeric cross-shaped extracellular matrix glycoproteins with terminal globular domains and a coiled-coil region through which the three chains are assembled and covalently linked. Laminins are key components of basement membranes, and they serve as attachment sites for cell adhesion, migration and proliferation. In this work, we produced a recombinant fragment comprising the entire laminin coiled-coil of the α1-, β1-, and γ1-chains that assemble into a stable heterotrimeric coiled-coil structure independently of the rest of the molecule. This domain was biologically active and not only failed to serve as a substrate for cell attachment, spreading and focal adhesion formation but also inhibited cell adhesion to laminin when added to cells in a soluble form at the time of seeding. Furthermore, gene array expression profiling in cells cultured in the presence of the laminin coiled-coil domain revealed up-regulation of genes involved in cell motility and invasion. These findings were confirmed by real-time quantitative PCR and zymography assays. In conclusion, this study shows for the first time that the laminin coiled-coil domain displays anti-adhesive functions and has potential implications for cell migration during matrix remodeling.

  20. Nucleocapsid formation and RNA synthesis of Marburg virus is dependent on two coiled coil motifs in the nucleoprotein

    Directory of Open Access Journals (Sweden)

    Lander Angelika

    2007-10-01

    Full Text Available Abstract The nucleoprotein (NP of Marburg virus (MARV is responsible for the encapsidation of viral genomic RNA and the formation of the helical nucleocapsid precursors that accumulate in intracellular inclusions in infected cells. To form the large helical MARV nucleocapsid, NP needs to interact with itself and the viral proteins VP30, VP35 and L, which are also part of the MARV nucleocapsid. In the present study, a conserved coiled coil motif in the central part of MARV NP was shown to be an important element for the interactions of NP with itself and VP35, the viral polymerase cofactor. Additionally, the coiled coil motif was essential for the formation of NP-induced intracellular inclusions and for the function of NP in the process of transcription and replication of viral RNA in a minigenome system. Transfer of the coiled coil motif to a reporter protein was sufficient to mediate interaction of the constructed fusion protein with the N-terminus of NP. The coiled coil motif is bipartite, constituted by two coiled coils which are separated by a flexible linker.

  1. The heterotrimeric laminin coiled-coil domain exerts anti-adhesive effects and induces a pro-invasive phenotype.

    Science.gov (United States)

    Santos-Valle, Patricia; Guijarro-Muñoz, Irene; Cuesta, Angel M; Alonso-Camino, Vanesa; Villate, Maider; Alvarez-Cienfuegos, Ana; Blanco, Francisco J; Sanz, Laura; Alvarez-Vallina, Luis

    2012-01-01

    Laminins are large heterotrimeric cross-shaped extracellular matrix glycoproteins with terminal globular domains and a coiled-coil region through which the three chains are assembled and covalently linked. Laminins are key components of basement membranes, and they serve as attachment sites for cell adhesion, migration and proliferation. In this work, we produced a recombinant fragment comprising the entire laminin coiled-coil of the α1-, β1-, and γ1-chains that assemble into a stable heterotrimeric coiled-coil structure independently of the rest of the molecule. This domain was biologically active and not only failed to serve as a substrate for cell attachment, spreading and focal adhesion formation but also inhibited cell adhesion to laminin when added to cells in a soluble form at the time of seeding. Furthermore, gene array expression profiling in cells cultured in the presence of the laminin coiled-coil domain revealed up-regulation of genes involved in cell motility and invasion. These findings were confirmed by real-time quantitative PCR and zymography assays. In conclusion, this study shows for the first time that the laminin coiled-coil domain displays anti-adhesive functions and has potential implications for cell migration during matrix remodeling.

  2. Rotating Cavitation Supression Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a rotating cavitation (RC) suppressor for liquid rocket engine turbopump inducers. Cavitation instabilities, such as rotating...

  3. Retrieval of unintended migrated detached coil: case report.

    Science.gov (United States)

    Oh, Jiwoong; Kim, Jongyun; Hong, Sunki; Hu, Chul; Pyen, Jinsu; Whang, Kum; Cho, Sungmin; You, Do-Sung

    2014-09-01

    Owing to the rapid development of intervention techniques and devices, endovascular coil embolization of cerebral arteries has become standardized. It is particularly preferred when a patient presents with an unruptured intracranial aneurysm of the posterior communicating artery (PcomA). However, the risk of thrombogenic complications of the coil migration may also result in a large cerebral infarction. When coil migration occurs during embolization, a procedure for removal of the embolic coil should be performed immediately. We experienced a clinically rare case of migration of a framing coil to the distal middle cerebral artery aneurysm during endovascular embolization of an unruptured PcomA aneurysm. The migrated coil was barely retrieved using snare techniques.

  4. Toroid cavity/coil NMR multi-detector

    Science.gov (United States)

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  5. Effects of coil length on tube compression in electromagnetic forming

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The effects of the length of solenoid coil on tube compression in electromagnetic forming were investigated either by theory analysis or through sequential coupling numerical simulation. The details of the electromagnetic and the mechanical models in the simulation were described. The results show that the amplitude of coil current waveform and the current frequency decrease with the increase of the coil length. And the peak value of magnetic pressure is inversely proportional to the coil length. The distribution of the magnetic force acting on the tube is inhomogeneous while the tube is longer than the coil. The shortened coil length causes the increases of the maximum deformation and energy efficiency. The numerically calculated result and the experimental one of the final tube profile are in good agreement.

  6. Ferrite core non-linearity in coils for magnetic neurostimulation.

    Science.gov (United States)

    RamRakhyani, Anil Kumar; Lazzi, Gianluca

    2014-10-01

    The need to correctly predict the voltage across terminals of mm-sized coils, with ferrite core, to be employed for magnetic stimulation of the peripheral neural system is the motivation for this work. In such applications, which rely on a capacitive discharge on the coil to realise a transient voltage curve of duration and strength suitable for neural stimulation, the correct modelling of the non-linearity of the ferrite core is critical. A demonstration of how a finite-difference model of the considered coils, which include a model of the current-controlled inductance in the coil, can be used to correctly predict the time-domain voltage waveforms across the terminals of a test coil is presented. Five coils of different dimensions, loaded with ferrite cores, have been fabricated and tested: the measured magnitude and width of the induced pulse are within 10% of simulated values.

  7. Coils and transformers - often used but seldomly explained correctly

    CERN Document Server

    Lenz, Michael

    2011-01-01

    The devices coil and transformer are subjects of interest in numerous schoolbooks, in introductory scientific textbooks of physics and engineering, and in laboratory courses at universities. Many descriptions, however, draw a somewhat distorted picture of the underlying physical mechanisms and provide half-knowledge or even clear misconceptions that should not be left uncommented and are therefore studied in detail: (1) Primary and secondary voltage at a transformer have a different sign. (2) Electromagnetic induction is the only mechanism of importance for coils and transformers. (3) The terminal voltage at coils and transformers is compensated by the so-called "induced voltage" (emf), which explains why Kirchhoff's voltage law also applies to coils and transformers. (4) The cores of coils and transformers are used for their ability to store energy. Energy is transported from the primary to the secondary coil within the magnetic core. (5) The stray magnetic and electric fields are sencondary effects not havi...

  8. Improving heat transfer in stirred tanks cooled by helical coils

    Directory of Open Access Journals (Sweden)

    S.M.C.P. Pedrosa

    2003-06-01

    Full Text Available Stirred Tank Reactors are extensively used in chemical industries. When they are used for highly exothermic reactions, jackets or coils are employed for heat removal. Internal coils can be either helical or axial and they considerably affect the flow inside the reactor because they impose an additional resistance to flow circulation. The aim of this work is to show that the design of vessels cooled by helical coils can be further improved. The design of these reactors follows very much the geometry proposed by Oldshue and Gretton (1954, and some minor modifications in the coil arrangements are likely to improve internal circulation inside these vessels mainly in the region between coils and wall of the vessel. Results show a gain in performance when small alterations are made specially in the shape of the coil arrangement.

  9. Experimental Study of Free Convection in Coiled Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Harith Mohammed

    2013-05-01

    Full Text Available An experimental study has been conducted on steady-state natural convection heat transfer from helical coil tubes in vertical orientation. Water was used as a bath liquid without any mixing and cold water was used as a coolant fluid. A straight copper tube of 6 mm ID, 8 mm OD and 3 m length was bend to fabricate the helical coil. Four coils are used in this experiment has different curvature ratios and pitches. The data were correlated using tube diameter as the characteristic length. The results show that the overall heat transfer coefficient and Nusselt number increase when the flow rate of coolant and curvature ratio increase. The effect of coil pitch was investigated and the results show that when of the coil pitch (angle of inclination increases Nusselt number increase. A correlation was presented to calculate the outside average Nusselt number of coil.

  10. Performance of an induction coil gun

    Energy Technology Data Exchange (ETDEWEB)

    Shokair, I.R.; Cowan, M.; Kaye, R.J.; Marder, B.M.

    1993-10-01

    Performance of an electromagnetic induction launcher is considered for three types of armatures. These are: Solid, 1-element wound and 16-element wound aluminum ar natures. The one element wound armature has uniform current density throughout. Because of the radial distribution of the current density, the wound armature can withstand field reversal (working against embedded flux in the armature) and still maintain low temperature. Slingshot simulations were performed, for several configurations. Best performance was obtained for a single element wound armature with two field reversals. For a 60 kg projectile, 10.5 cm coil inner radius and 5.5 cm coil build, the velocity after 50 meters of launcher length (670 stages) exceeded 3.5 km/sec with an overall efficiency of about 45%. For the same parameters the solid and 16-element wound armatures reach a velocity of about 3.3 km/sec after 800 stages (60 meters of launcher length) but without field reversal. A velocity of 3.5 km/sec is possible after 60 meters of launcher length with the 16-element wound armature with one field reversal, but the temperature is close to the melting temperature of aluminum. In all simulations with a solid armature, melting of some of the surface material occurs. However, it is shown that most of the melting occurs after contribution has been made to the forward going pressure, that is, melting does not affect the electrical performance of the launcher. The effect of coil firing tune jitter on launcher performance is also considered and is found to be very small for realistic perturbations. For {plus_minus}2 {mu}-secs random jitter, the reduction in the final velocity for a 60 meter launcher with a solid armature is less than 0.1% and the increase in temperature is only 2%. This result holds for all types of armatures.

  11. The need to generate realistic strain signals at an automotive coil spring for durability simulation leading to fatigue life assessment

    Science.gov (United States)

    Putra, T. E.; Abdullah, S.; Schramm, D.; Nuawi, M. Z.; Bruckmann, T.

    2017-09-01

    This study aims to accelerate fatigue tests using simulated strain signals. Strain signals were acquired from a coil spring involving car movements. Using a mathematical expression, the measured strain signals yielded acceleration signals, and were considered as disturbances on generating strain signals. The simulated strain signals gave the testing time deviation by only 1.5%. The wavelet-based data editing was applied to shorten the strain signals time up to 36.7% and reduced the testing time up to 33.9%. In conclusion, the simulated strain signals were able to maintain the majority of fatigue damage and decreased the testing time.

  12. Accelerating electromagnetic magic field from the C-metric

    CERN Document Server

    Bicak, Jiri; 10.1007/s10714-009-0816-8

    2009-01-01

    Various aspects of the C-metric representing two rotating charged black holes accelerated in opposite directions are summarized and its limits are considered. A particular attention is paid to the special-relativistic limit in which the electromagnetic field becomes the "magic field" of two oppositely accelerated rotating charged relativistic discs. When the acceleration vanishes the usual electromagnetic magic field of the Kerr-Newman black hole with gravitational constant set to zero arises. Properties of the accelerated discs and the fields produced are studied and illustrated graphically. The charges at the rim of the accelerated discs move along spiral trajectories with the speed of light. If the magic field has some deeper connection with the field of the Dirac electron, as is sometimes conjectured because of the same gyromagnetic ratio, the "accelerating magic field" represents the electromagnetic field of a uniformly accelerated spinning electron. It generalizes the classical Born's solution for two u...

  13. Intelligent Control on Hot Strip Coiling Temperature

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new intelligent control scheme for hot strip coiling temperature is presented. In this scheme, the prediction model of finishing temperature and the presetting model of main cooling zone are establish based on BP neural network, the feed-forward open-loop control model of main cooling zone is constructed based on T-S fuzzy neural network, a new improved structure of T-S fuzzy neural network is developed, and the feedback close-loop control model of precision cooling zone is obtained based on fuzzy control. The effectiveness of the proposed scheme has been demonstrated by computer simulation with a satisfactory result.

  14. Extreme acoustic metamaterial by coiling up space.

    Science.gov (United States)

    Liang, Zixian; Li, Jensen

    2012-03-16

    We show that by coiling up space using curled perforations, a two-dimensional acoustic metamaterial can be constructed to give a frequency dispersive spectrum of extreme constitutive parameters, including double negativity, a density near zero, and a large refractive index. Such an approach has band foldings at the effective medium regime without using local resonating subwavelength structures, while the principle can be easily generalized to three dimensions. Negative refraction with a double negative prism and tunneling with a density-near-zero metamaterial are numerically demonstrated.

  15. Sound Coiled-Tubing Drilling Practices

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Thomas; Deskins, Greg (Maurer Technology Inc.); Ward, Stephen L. (Advantage Energy Services Ltd); Hightower, Mel

    2001-09-30

    This Coiled-Tubing Drilling (CTD) Sound Practices Manual provides tools needed by CTD engineers and supervisors to plan, design and perform safe, successful CTD operations. As emphasized throughout, both careful planning and attention to detail are mandatory for success. A bibliography of many useful CTD references is presented in Chapter 6. This manual is organized according to three processes: 1) Pre-Job Planning Process, 2) Operations Execution Process, and 3) Post-Job Review Process. Each is discussed in a logical and sequential format.

  16. Effect of Inductive Coil Geometry on the Operating Characteristics of an Inductive Pulsed Plasma Thruster

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Kimberlin, Adam C.; Perdue, Kevin A.

    2012-01-01

    Operational characteristics of two separate inductive thrusters with conical theta pinch coils of different cone angles are explored through thrust stand measurements and time- integrated, unfiltered photography. Trends in impulse bit measurements indicate that, in the present experimental configuration, the thruster with the inductive coil possessing a smaller cone angle produced larger values of thrust, in apparent contradiction to results of a previous thruster acceleration model. Areas of greater light intensity in photographs of thruster operation are assumed to qualitatively represent locations of increased current density. Light intensity is generally greater in images of the thruster with the smaller cone angle when compared to those of the thruster with the larger half cone angle for the same operating conditions. The intensity generally decreases in both thrusters for decreasing mass flow rate and capacitor voltage. The location of brightest light intensity shifts upstream for decreasing mass flow rate of propellant and downstream for decreasing applied voltage. Recognizing that there typically exists an optimum ratio of applied electric field to gas pressure with respect to breakdown efficiency, this result may indicate that the optimum ratio was not achieved uniformly over the coil face, leading to non-uniform and incomplete current sheet formation in violation of the model assumption of immediate formation where all the injected propellant is contained in a magnetically-impermeable current sheet.

  17. MRI surface-coil pair with strong inductive coupling.

    Science.gov (United States)

    Mett, Richard R; Sidabras, Jason W; Hyde, James S

    2016-12-01

    A novel inductively coupled coil pair was used to obtain magnetic resonance phantom images. Rationale for using such a structure is described in R. R. Mett et al. [Rev. Sci. Instrum. 87, 084703 (2016)]. The original rationale was to increase the Q-value of a small diameter surface coil in order to achieve dominant loading by the sample. A significant improvement in the vector reception field (VRF) is also seen. The coil assembly consists of a 3-turn 10 mm tall meta-metallic self-resonant spiral (SRS) of inner diameter 10.4 mm and outer diameter 15.1 mm and a single-loop equalization coil of 25 mm diameter and 2 mm tall. The low-frequency parallel mode was used in which the rf currents on each coil produce magnetic fields that add constructively. The SRS coil assembly was fabricated and data were collected using a tissue-equivalent 30% polyacrylamide phantom. The large inductive coupling of the coils produces phase-coherency of the rf currents and magnetic fields. Finite-element simulations indicate that the VRF of the coil pair is about 4.4 times larger than for a single-loop coil of 15 mm diameter. The mutual coupling between coils influences the current ratio between the coils, which in turn influences the VRF and the signal-to-noise ratio (SNR). Data on a tissue-equivalent phantom at 9.4 T show a total SNR increase of 8.8 over the 15 mm loop averaged over a 25 mm depth and diameter. The experimental results are shown to be consistent with the magnetic resonance theory of the emf induced by spins in a coil, the theory of inductively coupled resonant circuits, and the superposition principle. The methods are general for magnetic resonance and other types of signal detection and can be used over a wide range of operating frequencies.

  18. Comparison of individual canine retraction using HYCON device and nickel titanium closed coil spring: In vivo study

    Directory of Open Access Journals (Sweden)

    Ruby Mathew

    2015-01-01

    Full Text Available Objective: To compare the individual canine retraction using HYCON device and Nickel Titanium closed coil springs. Materials and Methods: The sample consists of 20 patients, 10 males and 10 females. Class1 bimaxillary protrusion cases were selected for the study with age group ranging from 14 to 23 years. HYCON device was placed on the right side of the maxillary arch and Nickel Titanium closed coil spring were placed on left side of the maxillary arch. Lateral cephalograms, OPG and study models were taken before retraction (T0 and records were taken after retraction (T1. Results: The duration of this study is for 3 months. HYCON device retracted canines by 2.42 mm/mo whereas NiTi closed coil spring retracted canines by 1.34 mm/mo in a period of 3 months. Anchorage loss with a minimal of 1.40 mm is seen in HYCON device whereas in case of NiTi closed coil spring the anchorage loss was 3.35 mm. The angular rotation of canines measured was found to be 2.59 degrees in HYCON device and 10.80 in NiTi closed coil spring. Clinically and radiologically, in most of the cases canines moved bodily with 1.90 degrees of tipping for HYCON device while NiTi closed coil spring canine tipping was 6.95 degrees. Conclusion: For rapid space closure HYCON device is a promising appliance. With HYCON device, canines can be completely retracted in 3 months and there was bodily movement of canines seen in all cases with minimum amount of tipping.

  19. Siberian Snakes in high-energy accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Mane, S R [Convergent Computing Inc, PO Box 561, Shoreham, NY 11786 (United States); Shatunov, Yu M [Budker Institute of Nuclear Physics, Novosibirsk 630090 (Russian Federation); Yokoya, K [National Laboratory for High-Energy Physics (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2005-09-01

    We review modern techniques to accelerate spin-polarized beams to high energy and to preserve their polarization in storage rings. Crucial to the success of such work is the use of so-called Siberian Snakes. We explain these devices and the reason for their necessity. Closely related to Snakes is the concept of 'spin rotators'. The designs and merits of several types of Snakes and spin rotators are examined. Theoretical work with Snakes and spin rotators, and experimental results from several storage rings, are reviewed, including the so-called Snake resonances. (topical review)

  20. Exotic Rotational Correlations in Emergent Quantum Geometry

    CERN Document Server

    Hogan, Craig

    2015-01-01

    Estimates are presented of exotic, purely rotational correlations that arise in large systems if directions in space-time emerge from Planck scale quantum elements with no fixed classical background space. In the time domain, directions to world lines at finite separation $R$ from any world line coherently fluctuate in the classical (that is, $R\\rightarrow \\infty$) inertial frame, on a timescale $R/c$, by an angle of order $R^{-1/2}$ in Planck units. The exact exotic correlation function is computed for the signal in a Sagnac type interferometer of arbitrary shape. The signal variance is equal to twice the enclosed area divided by the perimeter, in Planck units. It is conjectured that exotic Planck scale rotational correlations, entangled with the strong interactions, determine the value of the cosmological constant. Cosmic acceleration may be viewed heuristically as centrifugal acceleration by rotational fluctuations of the matter vacuum. An experiment concept is sketched, based on a reconfiguration of the F...

  1. Statics and rotational dynamics of composite beams

    CERN Document Server

    Ghorashi, Mehrdaad

    2016-01-01

    This book presents a comprehensive study of the nonlinear statics and dynamics of composite beams and consists of solutions with and without active elements embedded in the beams. The static solution provides the initial conditions for the dynamic analysis. The dynamic problems considered include the analyses of clamped (hingeless) and articulated (hinged) accelerating rotating beams. Two independent numerical solutions for the steady state and the transient responses are presented. The author illustrates that the transient solution of the nonlinear formulation of accelerating rotating beam converges to the steady state solution obtained by the shooting method. Other key areas considered include calculation of the effect of perturbing the steady state solution, coupled nonlinear flap-lag dynamics of a rotating articulated beam with hinge offset and aerodynamic damping, and static and dynamic responses of nonlinear composite beams with embedded anisotropic piezo-composite actuators. The book is intended as a t...

  2. submitter On Roebel Cable Geometry for Accelerator Magnet

    CERN Document Server

    Fleiter, J; Ballarino, A

    2016-01-01

    Roebel-type cables made of a ReBCO conductor are potential candidates for high-field accelerator magnets. The necessity to promote a large effective transverse section in a Roebel cable to avoid local overstress leading to degradation in electrical performance has been recently addressed. In this paper, a new geometry of meander tapes for a Roebel cable that enhances both the transverse effective section and the current margin at crossing segments is discussed. As Roebel cables are bent at the coil ends, the modulation of the bending radius of strands along the cable pitch leads to a shift of the strands with respect to each other. The shift magnitude is analytically investigated in this paper as a function of both cable features and coil geometry. Finally, the minimum transposition pitch of Roebel cables is determined on the basis of coil characteristics.

  3. pH-dependent Response of Coiled Coils: A Coarse-Grained Molecular Simulation Study

    CERN Document Server

    Enciso, Marta; Site, Luigi Delle

    2013-01-01

    In a recent work we proposed a coarse-grained methodology for studying the response of peptides when simulated at different values of pH; in this work we extend the methodology to analyze the pH-dependent behavior of coiled coils. This protein structure presents a remarkable chain stiffness andis formed by two or more long helical peptides that are interacting like the strands of a rope. Chain length and rigidity are the key aspects needed to extend previous peptide interaction potentials to this particular case; however the original model is naturally recovered when the length or the ridigity of the simulated chain are reduced. We apply the model and discuss results for two cases: (a) the folding/unfolding transition of a generic coiled coil as a function of pH; (b) behavior of a specific sequence as a function of the acidity conditions. In this latter case results are compared with experimental data from the literature in order to comment about the consistency of our approach.

  4. An autoinhibited coiled-coil design strategy for split-protein protease sensors.

    Science.gov (United States)

    Shekhawat, Sujan S; Porter, Jason R; Sriprasad, Akshay; Ghosh, Indraneel

    2009-10-28

    Proteases are widely studied as they are integral players in cell-cycle control and apoptosis. We report a new approach for the design of a family of genetically encoded turn-on protease biosensors. In our design, an autoinhibited coiled-coil switch is turned on upon proteolytic cleavage, which results in the complementation of split-protein reporters. Utilizing this new autoinhibition design paradigm, we present the rational construction and optimization of three generations of protease biosensors, with the final design providing a 1000-fold increase in bioluminescent signal upon addition of the TEV protease. We demonstrate the generality of the approach utilizing two different split-protein reporters, firefly luciferase and beta-lactamase, while also testing our design in the context of a therapeutically relevant protease, caspase-3. Finally, we present a dual protease sensor geometry that allows for the use of these turn-on sensors as potential AND logic gates. Thus, these studies potentially provide a new method for the design and implementation of genetically encoded turn-on protease sensors while also providing a general autoinhibited coiled-coil strategy for controlling the activity of fragmented proteins.

  5. Peptidyl Materials Formed Through Click Chemistry Enhanced Coiled-Coil Interactions

    Science.gov (United States)

    Koehler, Kenneth

    2014-03-01

    Biologically derived materials offer a level of sophistication synthetically fabricated materials have only attempted to mimic. This level of complexity may be found in materials such as peptides. Implementing new theory and modeling, peptides with the propensity to form coiled-coil (CC) bundles were designed and synthesized. Through the use of this de novo approach, modeling allowed prediction of the feasibility to include non-natural amino acids conducive to click chemistry into the peptide. Amino acids showcasing thiol or alkyne functionalities were considered owing to the ability of these moieties to participate in the thiol-ene and copper click reactions respectively. Once synthesized, the peptides decorated with these clickable motifs were placed in solution and allowed to self-assemble into CC's. CD spectroscopy and DLS experiments confirmed the formation and assembly of CC's. Click reactions were then incited to link the CC assemblies together and form a network with predictable dimensionality and pore size between CC bundles. To incite network formation, click reactions between CC side chain residues and suitably functionalized crosslinkers were implemented. The linking of coiled-coils and material formation were assessed using DLS and TEM.

  6. Design of a single-chain polypeptide tetrahedron assembled from coiled-coil segments.

    Science.gov (United States)

    Gradišar, Helena; Božič, Sabina; Doles, Tibor; Vengust, Damjan; Hafner-Bratkovič, Iva; Mertelj, Alenka; Webb, Ben; Šali, Andrej; Klavžar, Sandi; Jerala, Roman

    2013-06-01

    Protein structures evolved through a complex interplay of cooperative interactions, and it is still very challenging to design new protein folds de novo. Here we present a strategy to design self-assembling polypeptide nanostructured polyhedra based on modularization using orthogonal dimerizing segments. We designed and experimentally demonstrated the formation of the tetrahedron that self-assembles from a single polypeptide chain comprising 12 concatenated coiled coil-forming segments separated by flexible peptide hinges. The path of the polypeptide chain is guided by a defined order of segments that traverse each of the six edges of the tetrahedron exactly twice, forming coiled-coil dimers with their corresponding partners. The coincidence of the polypeptide termini in the same vertex is demonstrated by reconstituting a split fluorescent protein in the polypeptide with the correct tetrahedral topology. Polypeptides with a deleted or scrambled segment order fail to self-assemble correctly. This design platform provides a foundation for constructing new topological polypeptide folds based on the set of orthogonal interacting polypeptide segments.

  7. mini-b-roll : LHC Accelerator

    CERN Document Server

    CERN Audiovisual Service

    2008-01-01

    How the LHC works The LHC, the world’s largest and most powerful particle accelerator, is the latest addition to CERN’s accelerator complex. It mainly consists of a 27 km ring of superconducting magnets with a number of accelerating structures to boost the energy of the particles along the way. Inside the accelerator, two beams of particles travel at close to the speed of light with very high energies before colliding with one another. The beams travel in opposite directions in separate beam pipes – two tubes kept at ultrahigh vacuum. They are guided around the accelerator ring by a strong magnetic field, achieved using superconducting electromagnets. These are built from coils of special electric cable that operates in a superconducting state, efficiently conducting electricity without resistance or loss of energy. This requires chilling the magnets to about ‑271°C – a temperature colder than outer space! For this reason, much of the accelerator is connected to a distribution system of liquid heli...

  8. Double Negativity in 3D Space Coiling Metamaterials

    Science.gov (United States)

    Maurya, Santosh K.; Pandey, Abhishek; Shukla, Shobha; Saxena, Sumit

    2016-09-01

    Metamaterials displaying negative refractive index has remarkable potential to facilitate the manipulation of incident waves for wide variety of applications such as cloaking, superlensing and the like. Space-coiling approach is a recently explored technique to achieve extreme properties. The space coiling phenomena cause less energy absorption as compared to local resonating phenomena for obtaining extreme parameters. Here we show extreme properties in doubly negative 3D space coiling acoustic metamaterials. Frequency dispersive spectrum of extreme constitutive parameters has been calculated for 2D maze and 3D space coiling labyrinthine structure. This is in good agreement to the calculated acoustic band dispersion.

  9. Performance verification tests of JT-60SA CS model coil

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Murakami, Haruyuki [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Chikaraishi, Hirotaka; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Natsume, Kyohei; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2015-11-15

    Highlights: • The performance of the JT-60SA CS model coil was verified. • The CS model coil comprised a quad-pancake wound with a Nb{sub 3}Sn CIC conductor. • The CS model coil met the design requirements. - Abstract: As a final check of the coil manufacturing method of the JT-60 Super Advanced (JT-60SA) central solenoid (CS), we verified the performance of a CS model coil. The model coil comprised a quad-pancake wound with a Nb{sub 3}Sn cable-in-conduit conductor. Measurements of the critical current, joint resistance, pressure drop, and magnetic field were conducted in the verification tests. In the critical-current measurement, the critical current of the model coil coincided with the estimation derived from a strain of −0.62% for the Nb{sub 3}Sn strands. As a result, critical-current degradation caused by the coil manufacturing process was not observed. The results of the performance verification tests indicate that the model coil met the design requirements. Consequently, the manufacturing process of the JT-60SA CS was established.

  10. Synthesis, characterisation and applications of coiled carbon nanotubes.

    Science.gov (United States)

    Hanus, Monica J; Harris, Andrew T

    2010-04-01

    Coiled carbon nanotubes are helical carbon structures formed when heptagonal and pentagonal rings are inserted into the hexagonal backbone of a 'straight' nanotube. Coiled carbon nanotubes have been reported with both regular and irregular helical structures. In this work the structure, growth mechanism(s), synthesis, properties and potential applications of coiled carbon nanotubes are reviewed. Published data suggests that coiled carbon nanotube synthesis occurs due to nonuniform extrusion of carbon from a catalyst surface. To date, coiled carbon nanotubes have been synthesised using catalyst modification techniques including: (i) the addition of S or P containing compounds during synthesis; (ii) the use of binary or ternary metal catalysts; (iii) the use of microwaves to create a local temperature gradient around individual catalyst particles and; (iv) the use of pH control during catalyst preparation. In most instances coiled carbon nanotubes are produced as a by-product; high yield and/or large-scale synthesis of coiled carbon nanotubes remains problematic. The qualitative analysis of coiled carbon nanotubes is currently hindered by the absence of specific characterisation data in the literature, e.g., oxidation profiles measured by thermogravimetric analysis and Raman spectra of pure coiled carbon nanotube samples.

  11. The Whole Elephant: A Synoptic View of Liquid Rope Coiling

    Science.gov (United States)

    Ribe, Neil

    2016-11-01

    Liquid rope coiling is the instability that occurs when e.g. a thin stream of honey is poured onto toast. While we now have a fine-grained understanding of each of the four principal coiling modes (viscous, gravitational, inertio-gravitational and inertial), we still lack a global view of how the modes cohere to form a larger whole. Using a numerical continuation procedure, I determine how the dimensionless coiling frequency depends on the dimensionless fall height and flow rate, for several values of the dimensionless nozzle diameter. Starting with the onset of coiling, I propose a purely geometrical definition of the critical surface between coiling and no coiling as the locus of points where the radius a1 of the rope at the contact point is just equal to the coil radius R. Coiling with a1 > R is impossible because the rope would intersect itself. I characterize the asymptotic limits of the critical surface as well as the structure of the supercritical volume inside that surface. The procedure reveals a new mode of coiling onset that has not yet been identified.

  12. Double Negativity in 3D Space Coiling Metamaterials.

    Science.gov (United States)

    Maurya, Santosh K; Pandey, Abhishek; Shukla, Shobha; Saxena, Sumit

    2016-09-21

    Metamaterials displaying negative refractive index has remarkable potential to facilitate the manipulation of incident waves for wide variety of applications such as cloaking, superlensing and the like. Space-coiling approach is a recently explored technique to achieve extreme properties. The space coiling phenomena cause less energy absorption as compared to local resonating phenomena for obtaining extreme parameters. Here we show extreme properties in doubly negative 3D space coiling acoustic metamaterials. Frequency dispersive spectrum of extreme constitutive parameters has been calculated for 2D maze and 3D space coiling labyrinthine structure. This is in good agreement to the calculated acoustic band dispersion.

  13. Magnetic resonance imaging receiver coil decoupling using circumferential shielding structures.

    Science.gov (United States)

    Yeh, Jhy-Neng Tasso; Fa-Hsuan Lin

    2016-08-01

    We propose a flexible phased-array design using circular coils with circumferential shielding structure to achieve robust decoupling between coil elements when the array is either bended or on a flat plane. Two types of circumferential shielding were tested through numerical simulation and imaging experiment. The results demonstrated that our arrays have good decoupling between coils when they are on a curved surface with S21 coil array. Future work will empirically construct a multi-channel array with the number of channel matched to commercial phased array in order to validate the performance in vivo.

  14. Dirty air conditioners: Energy implications of coil fouling

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Jeffrey; Walker, Iain; Sherman, Max

    2002-03-01

    Residential air conditioning is responsible for a substantial amount of peak electrical demand and energy consumption throughout most of the United States. Coil fouling, the deposition of indoor dusts and other particulate matter on evaporator heat exchangers, increases system pressure drop and, correspondingly, decreases system air flow and air conditioner performance. In this paper, we apply experimental and simulation results describing particle deposition on evaporator coils as well as research about indoor particle and dust concentrations to determine coil fouling rates. The results suggest that typical coils foul enough to double evaporator pressure drop in about 7.5 years, much sooner than the expected 15-30 year life time for an evaporator coil. The most important parameters in determining coil fouling times are the efficiency of the filter and indoor particle concentrations, although filter bypass and duct and coil design are important as well. The reduced air flows that result from coil fouling cause typical efficiency and capacity degradations of less than 5%, however they can be much greater for marginal systems or extreme conditions. These energy issues, as well as possible indoor air quality issues resulting from fouling by biological aerosols, suggest that regular coil cleaning to ameliorate low flow and the elimination of filter bypass should be an important part of residential air conditioning commissioning and maintenance practices.

  15. Developments of RF Coil for P in vivo NMR Spectroscopy .

    Directory of Open Access Journals (Sweden)

    S. Khushu

    1993-07-01

    Full Text Available RF receiver coils are very important parts of an NMR System. The design of these coils is very critical and has a dramatic effect on the SNR of the NMR signal and are generally developed in TRA/REC mode. This paper reports the developments of a 3.5 cm TRA/REC 26 MHz RF coil for P spectroscopy of small organs like thyroid. The coil is small in size, fits well in the neck for thyroid spectroscopy and is successfully working with the 1.5 tesla whole body Superconducting NMR System available at INMAS.

  16. Synchronous Generator with HTS-2G field coils for Windmills with output power 1 MW

    Science.gov (United States)

    Kovalev, K.; Kovalev, L.; Poltavets, V.; Samsonovich, S.; Ilyasov, R.; Levin, A.; Surin, M.

    2014-05-01

    Nowadays synchronous generators for wind-mills are developed worldwide. The cost of the generator is determined by its size and weight. In this deal the implementation of HTS-2G generators is very perspective. The application of HTS 2G field coils in the rotor allows to reduce the size of the generator is 1.75 times. In this work the design 1 MW HTS-2G generator is considered. The designed 1 MW HTS-2G generator has the following parameters: rotor diameter 800 mm, active length 400 mm, phase voltage 690V, rotor speed 600 min-1 rotor field coils with HTS-2G tapes. HTS-2G field coils located in the rotating cryostat and cooled by liquid nitrogen. The simulation and optimization of HTS-2G field coils geometry allowed to increase feed DC current up to 50A. Copper stator windings are water cooled. Magnetic and electrical losses in 1 MW HTS-2G generator do not exceed 1.6% of the nominal output power. In the construction of HTS-2G generator the wave multiplier with ratio 1:40 is used. The latter allows to reduce the total mass of HTS-2G generator down to 1.5 tons. The small-scale model of HTS-2G generator with output power 50 kW was designed, manufactured and tested. The test results showed good agreement with calculation results. The manufacturing of 1 MW HTS-2G generator is planned in 2014. This work is done under support of Rosatom within the frames of Russian Project "Superconducting Industry".

  17. Analysis of the cooldown of the ITER central solenoid model coil and insert coil

    Science.gov (United States)

    Bonifetto, R.; Brighenti, A.; Isono, T.; Martovetsky, N.; Kawano, K.; Savoldi, L.; Zanino, R.

    2017-01-01

    A series of superconducting insert coils (ICs) made of different materials has been tested since 2000 at JAEA Naka in the bore of the central solenoid model coil at fields up to 13 T and currents up to several tens of kA, fully representative of the ITER operating conditions. Here we focus on the 2015 test of the presently last IC of the series, the central solenoid (CS) insert coil, which was aimed at confirming the performance and properties of the Nb3Sn conductor, manufactured in Japan and used to wind the ITER CS modules in the US. As typical for these large scale applications, the cooldown (CD) from ambient to supercritical He temperature may take a long time, of the order of several weeks, so that it should be useful, also in the perspective of future IC tests, to optimize it. To that purpose, a comprehensive CD model implemented in the 4C code is developed and presented in this paper. The model is validated against the experimental data of an actual CD scenario, showing a very good agreement between simulation and measurements, from 300 to 4.5 K. The maximum temperature difference across the coil, which can only be roughly estimated from the measurements, is then extracted from the results of the simulation and shown to be much larger than the maximum value of 50 K, prescribed on the basis of the allowable thermal stress on the materials. An optimized CD scenario is finally designed using the model for the initial phase of the CD between 300 and 80 K, which allows reducing the needed time by ∼20%, while still satisfying the major constraints. Recommendations are also given for a better location/choice of the thermometers to be used for the monitoring of the maximum temperature difference across the coil.

  18. The Search Coil Magnetometer for THEMIS

    Science.gov (United States)

    Roux, A.; Le Contel, O.; Coillot, C.; Bouabdellah, A.; de La Porte, B.; Alison, D.; Ruocco, S.; Vassal, M. C.

    2008-12-01

    THEMIS instruments incorporate a tri-axial Search Coil Magnetometer (SCM) designed to measure the magnetic components of waves associated with substorm breakup and expansion. The three search coil antennas cover the same frequency bandwidth, from 0.1 Hz to 4 kHz, in the ULF/ELF frequency range. They extend, with appropriate Noise Equivalent Magnetic Induction (NEMI) and sufficient overlap, the measurements of the fluxgate magnetometers. The NEMI of the searchcoil antennas and associated pre-amplifiers is smaller than 0.76 pT /sqrt{Hz} at 10 Hz. The analog signals produced by the searchcoils and associated preamplifiers are digitized and processed inside the Digital Field Box (DFB) and the Instrument Data Processing Unit (IDPU), together with data from the Electric Field Instrument (EFI). Searchcoil telemetry includes waveform transmission, FFT processed data, and data from a filter bank. The frequency range covered depends on the available telemetry. The searchcoils and their three axis structures have been precisely calibrated in a calibration facility, and the calibration of the transfer function is checked on board, usually once per orbit. The tri-axial searchcoils implemented on the five THEMIS spacecraft are working nominally.

  19. A novel method for coiled tubing installation

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, Peter J. [2H Offshore, Houston, TX (United States); Tibbetts, David [Aquactic Engineering and Construction Ltd., Aberdeen (United Kingdom)

    2009-12-19

    Installation of flexible pipe for offshore developments is costly due to the physical cost of the flexible pipe, expensive day rates and the availability of suitable installation vessels. Considering the scarcity of flexible pipe in today's increasingly demanding and busy market, operators are seeking a cost effective solution for installing piping in a range of water depths using vessels which are readily on hand. This paper describes a novel approach to installing reeled coiled tubing, from 1 inch to 5 inch diameter, from the back of a small vessel in water depths from 40 m up to around 1000 m. The uniqueness of the system is the fact that the equipment design is modular and compact. This means that when disassembled, it fits into standard 40 ft shipping containers, and the size allows it to be installed on even relatively small vessels of opportunity, such as anchor handling or installation vessels, from smaller, and cheaper quay side locations. Such an approach is the ideal solution to the problem faced by operators, in that it allows the installation of cheaper, readily available coiled tubing, from cost-effective vessels, which do not need to transit to a pick up the system. (author)

  20. ΛCDM is Consistent with SPARC Radial Acceleration Relation

    Science.gov (United States)

    Keller, B. W.; Wadsley, J. W.

    2017-01-01

    Recent analysis of the Spitzer Photometry and Accurate Rotation Curve (SPARC) galaxy sample found a surprisingly tight relation between the radial acceleration inferred from the rotation curves and the acceleration due to the baryonic components of the disk. It has been suggested that this relation may be evidence for new physics, beyond ΛCDM. In this Letter, we show that 32 galaxies from the MUGS2 match the SPARC acceleration relation. These cosmological simulations of star-forming, rotationally supported disks were simulated with a WMAP3 ΛCDM cosmology, and match the SPARC acceleration relation with less scatter than the observational data. These results show that this acceleration relation is a consequence of dissipative collapse of baryons, rather than being evidence for exotic dark-sector physics or new dynamical laws.

  1. Thrust Stand Measurements of the Microwave Assisted Discharge Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Emsellem, Gregory D.

    2011-01-01

    Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. This type of pulsed thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Dis- charge Inductive Plasma Accelerator (MAD-IPA), shown in Fig. 1, is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil before the main current pulse via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and a static magnetic field from a set of permanent magnets arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the theta-pinch coil is high. The use of a conical theta-pinch coil also serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [1, 2]. In this paper, we describe thrust stand measurements performed to characterize the performance (specific impulse, thrust efficiency) of the MAD-IPA thruster. Impulse data are obtained at various pulse energies, mass flow rates and inductive coil geometries. Dependencies on these experimental parameters are discussed in the context of the current sheet formation and electromagnetic plasma

  2. Solutions for Safe Hot Coil Evacuation and Coil Handling in Case of Thick and High Strength Steel

    Directory of Open Access Journals (Sweden)

    Sieberer Stefan

    2016-01-01

    Full Text Available Currently hot rolling plants are entering the market segment for thick gauges and high strength steel grades where the elastic bending property of the strip leads to internal forces in the coil during coiling operation. The strip tends to open. Primetals is investigating several possibilities to facilitate safe coil evacuation and coil handling under spring-back conditions. The contribution includes finite element models of such mechanical solutions. Results of parameter variation and stability limits of case studies are presented in the paper.

  3. Self-assembly of designed coiled coil peptides studied by small-angle X-ray scattering and analytical ultracentrifugation

    DEFF Research Database (Denmark)

    Malik, Leila; Nygaard, Jesper; Christensen, Niels Johan;

    2013-01-01

    α-Helical coiled coil structures, which are noncovalently associated heptad repeat peptide sequences, are ubiquitous in nature. Similar amphipathic repeat sequences have also been found in helix-containing proteins and have played a central role in de novo design of proteins. In addition......, they are promising tools for the construction of nanomaterials. Small-angle X-ray scattering (SAXS) has emerged as a new biophysical technique for elucidation of protein topology. Here, we describe a systematic study of the self-assembly of a small ensemble of coiled coil sequences using SAXS and analytical...

  4. Effect of inductive coil shape on sensing performance of linear displacement sensor using thin inductive coil and pattern guide.

    Science.gov (United States)

    Misron, Norhisam; Ying, Loo Qian; Firdaus, Raja Nor; Abdullah, Norrimah; Mailah, Nashiren Farzilah; Wakiwaka, Hiroyuki

    2011-01-01

    This paper discusses the effect of inductive coil shape on the sensing performance of a linear displacement sensor. The linear displacement sensor consists of a thin type inductive coil with a thin pattern guide, thus being suitable for tiny space applications. The position can be detected by measuring the inductance of the inductive coil. At each position due to the change in inductive coil area facing the pattern guide the value of inductance is different. Therefore, the objective of this research is to study various inductive coil pattern shapes and to propose the pattern that can achieve good sensing performance. Various shapes of meander, triangular type meander, square and circle shape with different turn number of inductive coils are examined in this study. The inductance is measured with the sensor sensitivity and linearity as a performance evaluation parameter of the sensor. In conclusion, each inductive coil shape has its own advantages and disadvantages. For instance, the circle shape inductive coil produces high sensitivity with a low linearity response. Meanwhile, the square shape inductive coil has a medium sensitivity with higher linearity.

  5. Development of Ground Coils with Low Eddy Current Loss by Applying the Compression Molding Method after the Coil Winding

    Science.gov (United States)

    Suzuki, Masao; Aiba, Masayuki; Takahashi, Noriyuki; Ota, Satoru; Okada, Shigenori

    In a magnetically levitated transportation (MAGLEV) system, a huge number of ground coils will be required because they must be laid for the whole line. Therefore, stable performance and reduced cost are essential requirements for the ground coil development. On the other hand, because the magnetic field changes when the superconducting magnet passes by, an eddy current will be generated in the conductor of the ground coil and will result in energy loss. The loss not only increases the magnetic resistance for the train running but also brings an increase in the ground coil temperature. Therefore, the reduction of the eddy current loss is extremely important. This study examined ground coils in which both the eddy current loss and temperature increase were small. Furthermore, quantitative comparison for the eddy current loss of various magnet wire samples was performed by bench test. On the basis of the comparison, a round twisted wire having low eddy current loss was selected as an effective ground coil material. In addition, the ground coils were manufactured on trial. A favorable outlook to improve the size accuracy of the winding coil and uneven thickness of molded resin was obtained without reducing the insulation strength between the coil layers by applying a compression molding after winding.

  6. Meta-analysis of stent-assisted coiling versus coiling-only for the treatment of intracranial aneurysms.

    Science.gov (United States)

    Phan, Kevin; Huo, Ya R; Jia, Fangzhi; Phan, Steven; Rao, Prashanth J; Mobbs, Ralph J; Mortimer, Alex M

    2016-09-01

    Endovascular coil embolization is a widely accepted and useful treatment modality for intracranial aneurysms. However, the principal limitation of this technique is the high aneurysm recurrence. The adjunct use of stents for coil embolization procedures has revolutionized the field of endovascular aneurysm management, however its safety and efficacy remains unclear. Two independent reviewers searched six databases from inception to July 2015 for trials that reported outcomes according to those who received stent-assisted coiling versus coiling-only (no stent-assistance). There were 14 observational studies involving 2698 stent-assisted coiling and 29,388 coiling-only patients. The pooled immediate occlusion rate for stent-assisted coiling was 57.7% (range: 20.2%-89.2%) and 48.7% (range: 31.7%-89.2%) for coiling-only, with no significant difference between the two (odds ratio [OR}=1.01; 95% confidence intervals [CI}: 0.68-1.49). However, progressive thrombosis was significantly more likely in stent-assisted coiling (29.9%) compared to coiling-only (17.5%) (OR=2.71; 95% CI: 1.95-3.75). Aneurysm recurrence was significantly lower in stent-assisted coiling (12.7%) compared to coiling-only (27.9%) (OR=0.43; 95% CI: 0.28-0.66). In terms of complications, there was no significant difference between the two techniques for all-complications, permanent complications or thrombotic complications. Mortality was significantly higher in the stent-assisted group 1.4% (range: 0%-27.5%) compared to the coiling-only group 0.2% (range: 0%-19.7%) (OR=2.16; 95% CI: 1.33-3.52). Based on limited evidence, stent-assisted coiling shows similar immediate occlusion rates, improved progressive thrombosis and decreased aneurysm recurrence compared to coiling-only, but is associated with a higher mortality rate. Future randomized controlled trials are warranted to clarify the safety of stent-associated coiling.

  7. Gravity-dependent differentiation and root coils in Arabidopsis thaliana wild type and phospholipase-A-I knockdown mutant grown on the International Space Station.

    Science.gov (United States)

    Scherer, G F E; Pietrzyk, P

    2014-01-01

    Arabidopsis roots on 45° tilted agar in 1-g grow in wave-like figures. In addition to waves, formation of root coils is observed in several mutants compromised in gravitropism and/or auxin transport. The knockdown mutant ppla-I-1 of patatin-related phospholipase-A-I is delayed in root gravitropism and forms increased numbers of root coils. Three known factors contribute to waving: circumnutation, gravisensing and negative thigmotropism. In microgravity, deprivation of wild type (WT) and mutant roots of gravisensing and thigmotropism and circumnutation (known to slow down in microgravity, and could potentially lead to fewer waves or increased coiling in both WT and mutant). To resolve this, mutant ppla-I-1 and WT were grown in the BIOLAB facility in the International Space Station. In 1-g, roots of both types only showed waving. In the first experiment in microgravity, the mutant after 9 days formed far more coils than in 1-g but the WT also formed several coils. After 24 days in microgravity, in both types the coils were numerous with slightly more in the mutant. In the second experiment, after 9 days in microgravity only the mutant formed coils and the WT grew arcuated roots. Cell file rotation (CFR) on the mutant root surface in microgravity decreased in comparison to WT, and thus was not important for coiling. Several additional developmental responses (hypocotyl elongation, lateral root formation, cotyledon expansion) were found to be gravity-influenced. We tentatively discuss these in the context of disturbances in auxin transport, which are known to decrease through lack of gravity. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.

  8. Physiological and pathological responses to head rotations in toddler piglets.

    Science.gov (United States)

    Ibrahim, Nicole G; Ralston, Jill; Smith, Colin; Margulies, Susan S

    2010-06-01

    Closed head injury is the leading cause of death in children less than 4 years of age, and is thought to be caused in part by rotational inertial motion of the brain. Injury patterns associated with inertial rotations are not well understood in the pediatric population. To characterize the physiological and pathological responses of the immature brain to inertial forces and their relationship to neurological development, toddler-age (4-week-old) piglets were subjected to a single non-impact head rotation at either low (31.6 +/- 4.7 rad/sec(2), n = 4) or moderate (61.0 +/- 7.5 rad/sec(2), n = 6) angular acceleration in the axial direction. Graded outcomes were observed for both physiological and histopathological responses such that increasing angular acceleration and velocity produced more severe responses. Unlike low-acceleration rotations, moderate-acceleration rotations produced marked EEG amplitude suppression immediately post-injury, which remained suppressed for the 6-h survival period. In addition, significantly more severe subarachnoid hemorrhage, ischemia, and axonal injury by beta-amyloid precursor protein (beta-APP) were observed in moderate-acceleration animals than low-acceleration animals. When compared to infant-age (5-day-old) animals subjected to similar (54.1 +/- 9.6 rad/sec(2)) acceleration rotations, 4-week-old moderate-acceleration animals sustained similar severities of subarachnoid hemorrhage and axonal injury at 6 h post-injury, despite the larger, softer brain in the older piglets. We conclude that the traditional mechanical engineering approach of scaling by brain mass and stiffness cannot explain the vulnerability of the infant brain to acceleration-deceleration movements, compared with the toddler.

  9. Optimization of capacitor coil targets for generation of mega Gauss level magnetic fields using kJ-ns class lasers

    Science.gov (United States)

    Kumar, Deepak; Collaborative Team

    2016-10-01

    A controlled magnetic field is extremely useful in various laser plasma experiments, especially in the fields of fast ignition, laboratory astrophysics and charged particle beam lensing. MG level fields for such applications can be created by the interaction of a kJ-ns class laser with a capacitor-coil target. Previous experiments with such targets rely on the ablated plasma short circuiting the capacitor target, which causes a current to flow through the coil. In recently concluded experiments at the Prague Asterix Laser Facility we used the Iodine laser (600 J, 350 ps, Iλ2 =1016 -1017 W/cm2) with targets of varying capacitance designed so that the plasma did not short circuit the opposite plates. Such a design is also beneficial for future applications, where the magnetized targets are not affected by the ablated plasma. Spatial and temporal behavior of the magnetic field was inferred by measuring the Faraday rotation through a TGG crystal placed near the coil. A B-dot probe provided qualitative information on the timescale of evolution of current in the coil, and an electron spectrometer measured the distribution of the hot electrons. This talk will describe the experimental setup and the results of magnetic field measurement for various targets.

  10. Design of Rotating Moving-Magnet-Type VCM Actuator for Miniaturized Mobile Robot

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Bu Hyun [Hanbat Nat' l Univ., Daejeon (Korea, Republic of); Lee, Seungyop [Sogana Univ., Seoul (Korea, Republic of); Lee, Kyungmin [Korean Intellectual Property Office, Seoul (Korea, Republic of); Oh, Dongho [Chungnam Nat' l Univ., Daejeon (Korea, Republic of)

    2013-12-15

    A voice coil actuator with a rotating moving magnet has been developed for a miniaturized mobile robot. The actuator has simple structure comprising a magnet, a coil, and a yoke. Actuator performance is predicted using a linearized theoretical model, and dynamic performance based on the air-gap between the magnet and the coil is predicted using motor constant and restoring constant obtained through finite element simulations. The theoretical model was verified using a prototype with 60 Hz resonance and 80 Hz bandwidth. We found that an input of 1.5 V can make the actuator rotate by 20 .deg. statically. The driving configuration of the proposed actuator can be simplified because of its implementation of open-loop control.

  11. Helical spin rotators and snakes for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Ptitsin, V.I.; Shatunov, Yu.M. [Budker Inst. of Nuclear Physics, Novosibirsk (Russian Federation); Peggs, S. [Brookhaven National Lab., Upton, NY (United States)

    1995-05-01

    The RHIC collider, now under construction at BNL, will have the possibility of polarized proton-proton collisions up to a beam energy of 250 Gev. Polarized proton beams of such high energy can be only obtained with the use of siberian snakes, a special kind of spin rotator that rotates the particle spin by 180{degree} around an axis lying in the horizontal plane. Siberian snakes help to preserve the beam polarization while numerous spin depolarizing resonances are crossed, during acceleration. In order to collide longitudinally polarized beams, it is also planned to install spin rotators around two interaction regions. This paper discusses snake and spin rotator designs based on sequences of four helical magnets. The schemes that were chosen to be applied at RHIC are presented.

  12. Observation of Bloch oscillations in molecular rotation

    CERN Document Server

    Floß, Johannes; Averbukh, Ilya Sh; Bucksbaum, Philip H

    2015-01-01

    The periodically kicked quantum rotor is known for non-classical effects such as quantum localisation in angular momentum space or quantum resonances in rotational excitation. These phenomena have been studied in diverse systems mimicking the kicked rotor, such as cold atoms in optical lattices, or coupled photonic structures. Recently, it was predicted that several solid state quantum localisation phenomena - Anderson localisation, Bloch oscillations, and Tamm-Shockley surface states - may manifest themselves in the rotational dynamics of laser-kicked molecules. Here, we report the first observation of rotational Bloch oscillations in a gas of nitrogen molecules kicked by a periodic train of femtosecond laser pulses. A controllable detuning from the quantum resonance creates an effective accelerating potential in angular momentum space, inducing Bloch-like oscillations of the rotational excitation. These oscillations are measured via the temporal modulation of the refractive index of the gas. Our results int...

  13. Relativistic Rotation: A Comparison of Theories

    CERN Document Server

    Klauber, R D

    2006-01-01

    Alternative theories of relativistic rotation considered viable as of 2004 are compared in the light of experiments reported in 2005. En route, the contentious issue of simultaneity choice in rotation is resolved by showing that only one simultaneity choice, the one possessing continuous time, gives rise, via the general relativistic equation of motion, to the correct Newtonian limit Coriolis acceleration. In addition, the widely dispersed argument purporting to justify an absolute Lorentz contraction in rotation is analyzed and found lacking for more than one reason. It is argued that only via experiment can we know whether such absolute contraction exists in rotation or not. The Coriolis/simultaneity correlation, and the results of the 2005 experiments, support the Selleri theory as being closest to the truth, though it is incomplete in a more general applicability sense, because it does not provide a global metric. Two alternatives, a modified Klauber approach and a Selleri-Klauber hybrid, are presented wh...

  14. The human ocular torsion position response during yaw angular acceleration.

    Science.gov (United States)

    Smith, S T; Curthoys, I S; Moore, S T

    1995-07-01

    Recent results by Wearne [(1993) Ph.D. thesis] using the scleral search-coil method of measuring eye position indicate that changes in ocular torsion position (OTP) occur during yaw angular acceleration about an earth vertical axis. The present set of experiments, using an image processing method of eye movement measurement free from the possible confound of search coil slippage, demonstrates the generality and repeatability of this phenomenon and examines its possible causes. The change in torsion position is not a linear vestibulo-ocular reflex (LVOR) response to interaural linear acceleration stimulation of the otoliths, but rather the effect is dependent on the characteristics of the angular acceleration stimulus, commencing at the onset and decaying at the offset of the angular acceleration. In the experiments reported here, the magnitude of the angular acceleration stimulus was varied and the torsion position response showed corresponding variations. We consider that the change in torsion position observed during angular acceleration is most likely to be due to activity of the semicircular canals.

  15. Simulations of Twin-Box Joints for ITER PF Coils

    NARCIS (Netherlands)

    Ilyin, Y.; Rolando, G.; Nijhuis, A.; Simon, F.; Lim, B.S.; Mitchell, N.; Turck, B.

    2014-01-01

    An ITER Poloidal Field coil winding consists of stacked double pancakes wound with NbTi cable-in-conduit conductors. One of the critical components of the coil is the electrical joint connecting either two conductor lengths within a double pancake or two double pancakes. All joints utilize the twin-

  16. Temperature Profile Measurements During Heat Treatment of BSCCO 2212 Coils

    CERN Document Server

    ,

    2012-01-01

    The temperature profile of two different BSCCO 2212 coils has been analyzed. The profiles are obtained from thermocouples imbedded in the windings during the heat treatment that activates the 2212. The melting and freezing of the 2212 is clearly observed. A model that describes the data and can be used to guide the processing of new coils has been developed.

  17. ATLAS-Lowering the first Barrel Toroid coil

    CERN Multimedia

    CERN Audiovisual Unit

    2004-01-01

    Cranes lowered the first of ATLAS's eight Barrel Toroid coils into the cavern. The part is 25 meters long and the cranes had to hold the 100 tonne coil at a sharp angle while it passed through the 18-meter diameter vertical shaft into the cavern. Then they laid the magnet to a horizontal robust platform. Images from Camera 2

  18. Bioaerosol deposition on an air-conditioning cooling coil

    Science.gov (United States)

    Wu, Yan; Chen, Ailu; Luhung, Irvan; Gall, Elliott T.; Cao, Qingliang; Chang, Victor Wei-Chung; Nazaroff, William W.

    2016-11-01

    This study is concerned with the role of a fin-and-tube heat exchanger in modifying microbial indoor air quality. Specifically, depositional losses of ambient bioaerosols and particles onto dry (not cooled) and wet (cool) coil surfaces were measured for different airspeeds passing through the test coil. Total, bacterial and fungal DNA concentrations in condensate water produced by a wet coil were also quantified by means of fluorescent dsDNA-binding dye and qPCR assays. Results revealed that the deposition of bioaerosols and total particles is substantial on coil surfaces, especially when wet and cool. The average deposition fraction was 0.14 for total DNA, 0.18 for bacterial DNA and 0.22 for fungal DNA on the dry coil, increasing to 0.51 for total DNA, 0.50 for bacterial DNA and 0.68 for fungal DNA on the wet coil. Overall, as expected, deposition fractions increased with increasing particle size and increasing airspeed. Deposited DNA was removed from the cooling coil surfaces through the flow of condensing water at a rate comparable to the rate of direct deposition from air. A downward trend of bacterial and fungal DNA measured in condensate water over time provides suggestive evidence of biological growth on heat exchangers during nonoperational times of a ventilation system. This investigation provides new information about bioaerosol deposition onto a conventional fin-and-tube cooling coil, a potentially important factor influencing indoor exposure to microbial aerosols in air-conditioned buildings.

  19. Magnetic field measurements of JT-60SA CS model coil

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Chikaraishi, Hirotaka; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Murakami, Haruyuki; Natsume, Kyohei; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2015-01-15

    Highlights: • Magnetic fields of the JT-60SA CS model coil were measured. • While the coil current was held constant at 20 kA, magnetic fields varied slightly with several different long time constants. • We investigated coils consisting of CIC conductors and having long time constants. - Abstract: In a cold test of the JT-60SA CS model coil, which has a quad-pancake configuration consisting of a Nb{sub 3}Sn cable-in-conduit (CIC) conductor, magnetic fields were measured using Hall sensors. For a holding coil current of 20 kA, measured magnetic fields varied slightly with long time constants in the range 17–571 s, which was much longer than the time constant derived from a measurement using a short straight sample. To validate the measurements, the magnetic fields of the model coil were calculated using a computational model representing the positions of Nb{sub 3}Sn strands inside the CIC conductor. The calculated results were in good agreement with the measurements. Consequently, the validity of the magnetic field measurements was confirmed. Next, we investigated other coils consisting of CIC conductors and having long time constants. The only commonality among the coils was the use of CIC conductors. At present, there is no obvious way to prevent generation of such magnetic-field variations with long time constants.

  20. Impulse and Frequency Response of a Moving Coil Galvanometer.

    Science.gov (United States)

    McNeill, D. J.

    1985-01-01

    Describes an undergraduate laboratory experiment in which a moving coil galvanometer is studied and the electromotive force generated by the swinging coil provides the impulse response information in a form suitable for digitizing and inputing to a microcomputer. Background information and analysis of typical data are included. (JN)