WorldWideScience

Sample records for rotating gantry port

  1. The Development and Clinical Use of a Beam ON-LINE PET System Mounted on a Rotating Gantry Port in Proton Therapy

    International Nuclear Information System (INIS)

    Nishio, Teiji; Miyatake, Aya; Ogino, Takashi; Nakagawa, Keiichi; Saijo, Nagahiro; Esumi, Hiroyasu

    2010-01-01

    Purpose: To verify the usefulness of our developed beam ON-LINE positron emission tomography (PET) system mounted on a rotating gantry port (BOLPs-RGp) for dose-volume delivery-guided proton therapy (DGPT). Methods and Materials: In the proton treatment room at our facility, a BOLPs-RGp was constructed so that a planar PET apparatus could be mounted with its field of view covering the iso-center of the beam irradiation system. Activity measurements were performed in 48 patients with tumors of the head and neck, liver, lungs, prostate, and brain. The position and intensity of the activity were measured using the BOLPs-RGp during the 200 s immediately after the proton irradiation. Results: The daily measured activity images acquired by the BOLPs-RGp showed the proton irradiation volume in each patient. Changes in the proton-irradiated volume were indicated by differences between a reference activity image (taken at the first treatment) and the daily activity-images. In the case of head-and-neck treatment, the activity distribution changed in the areas where partial tumor reduction was observed. In the case of liver treatment, it was observed that the washout effect in necrotic tumor cells was slower than in non-necrotic tumor cells. Conclusions: The BOLPs-RGp was developed for the DGPT. The accuracy of proton treatment was evaluated by measuring changes of daily measured activity. Information about the positron-emitting nuclei generated during proton irradiation can be used as a basis for ensuring the high accuracy of irradiation in proton treatment.

  2. Proposal of cancer therapy system without rotating gantry

    International Nuclear Information System (INIS)

    Kodaira, Masanobu

    2002-01-01

    Beam therapy is one of useful methods for cancer therapy. Many results in National Institute of Radiological Sciences (NIRS) show many abilities of beam therapy for cancer therapy. In Japan, several beam therapy facilities are constructed or under construction. If its construction budget becomes to be smaller, beam therapy may be used as the general cancer therapy. But in the present beam therapy facilities, the budget of its construction is very large. One of the reasons of big budget is the construction of the big buildings equipped with thick shielding walls. Most of space of the facilities with thick shielding walls is devoted to the treatment equipments such as rotating gantries and beam transport lines. This proposal is that using oblique beam line and rotating treatment bed, multi-portal irradiation is realized without rotating gantry. At the same time, we designed adequate beam lines to minimize the total facilities. (author)

  3. A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation.

    Science.gov (United States)

    Rowshanfarzad, P; Riis, H L; Zimmermann, S J; Ebert, M A

    2015-07-01

    In radiotherapy treatments, it is crucial to monitor the performance of linear accelerator (linac) components, including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. The EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt and the sag in leaf bank assembly owing to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with 5 ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of the image data. Nine Elekta AB (Stockholm, Sweden) linacs of different models and number of years in service were investigated. The average EPID sag was within 2 mm for all tested linacs. Some machines showed >1-mm gantry sag. Changes in the SDD values were within 1.3 cm. EPID skewness and tilt values were <1° in all machines. The maximum sag in multileaf collimator leaf bank assemblies was around 1 mm. A meaningful correlation was found between the age of the linacs and their mechanical performance. Conclusions and Advances in knowledge: The method and software developed in this study provide a simple tool for effective investigation of the behaviour of Elekta linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Elekta machines.

  4. SU-E-P-45: An Analytical Formula for Deriving Mechanical Iso-Center of Rotational Gantry Treatment Unit Rotational Gantry Treatment Unit

    International Nuclear Information System (INIS)

    Ding, X; Bues, M

    2015-01-01

    Purpose: To present an analytical formula for deriving mechanical isocenter (MIC) of a rotational gantry treatment unit. The input data to the formula is obtained by a custom-made device. The formula has been implemented and used in an operational proton therapy facility since 2005. Methods: The custom made device consisted of 3 mutually perpendicular dial indicators and 5 clinometers, to obtain displacement data and gantry angle data simultaneously. During measurement, a steel sphere was affixed to the patient couch, and the device was attached to the snout rotating with the gantry. The displacement data and angle data were obtained simultaneously at angular increments of less than 1 degree. The analytical formula took the displacement and angle as input and derived the positions of dial indicator tips (DIT) position in room-fixed coordinate system. The formula derivation presupposes trigonometry and 3-dimentional coordinate transformations. Due to the symmetry properties of the defining equations, the DIT position can be solved for analytically without using mathematical approximations. We define the mean of all points in the DIT trajectory as the MIC. The formula was implemented in computer code, which has been employed during acceptance test, commissioning, as well as routine QA practice in an operational proton facility since 2005. Results: It took one minute for the custom-made device to acquire the measurement data for a full gantry rotation. The DIT trajectory and MIS are instantaneously available after the measurement. The MIC Result agrees well with vendor’s Result, which came from a different measurement setup, as well as different data analysis algorithm. Conclusion: An analytical formula for deriving mechanical isocenter was developed and validated. The formula is considered to be absolutely accurate mathematically. Be analyzing measured data of radial displacements as function of gantry angle, the formula calculates the MI position in room

  5. Design and Test Results of Superconducting Magnet for Heavy-Ion Rotating Gantry

    Science.gov (United States)

    Takayama, S.; Koyanagi, K.; Miyazaki, H.; Takami, S.; Orikasa, T.; Ishii, Y.; Kurusu, T.; Iwata, Y.; Noda, K.; Obana, T.; Suzuki, K.; Ogitsu, T.; Amemiya, N.

    2017-07-01

    Heavy-ion radiotherapy has a high curative effect in cancer treatment and also can reduce the burden on patients. These advantages have been generally recognized. Furthermore, a rotating gantry can irradiate a tumor with ions from any direction without changing the position of the patient. This can reduce the physical dose on normal cells, and is thus commonly used in proton radiotherapy. However, because of the high magnetic rigidity of carbon ions, the weight of the rotating gantry for heavy-ion therapy is about three-times heavier than those used for proton cancer therapy, according to our estimation. To overcome this issue, we developed a small and lightweight rotating gantry in collaboration with the National Institute of Radiological Sciences (NIRS). The compact rotating gantry was composed of ten low-temperature superconducting (LTS) magnets that were designed from the viewpoint of beam optics. These LTS magnets have a surface-winding coil-structure and provide both dipole and quadrupole fields. The maximum dipole and quadrupole magnetic field of the magnets were 2.88 T and 9.3 T/m, respectively. The rotating gantry was installed at NIRS, and beam commissioning is in progress to achieve the required beam quality. In the three years since 2013, in a project supported by the Ministry of Economy, Trade and Industry (METI) and the Japan Agency for Medical Research and Development (AMED), we have been developing high-temperature superconducting (HTS) magnets with the aim of a further size reduction of the rotating gantry. To develop fundamental technologies for designing and fabricating HTS magnets, a model magnet was manufactured. The model magnet was composed of 24 saddle-shaped HTS coils and generated a magnetic field of 1.2 T. In the presentation, recent progress in this research will be reported.

  6. Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

    International Nuclear Information System (INIS)

    Schiefer, H.; Peters, S.; Plasswilm, L.; Ingulfsen, N.; Kluckert, J.

    2015-01-01

    Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery

  7. Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

    Energy Technology Data Exchange (ETDEWEB)

    Schiefer, H., E-mail: johann.schiefer@kssg.ch; Peters, S.; Plasswilm, L. [Klinik für Radio-Onkologie, Kantonsspital St.Gallen, Rorschacherstrasse 107, St.Gallen CH-9007 (Switzerland); Ingulfsen, N.; Kluckert, J. [Kantonsschule am Burggraben St.Gallen, Burggraben 21, St.Gallen CH-9000 (Switzerland)

    2015-03-15

    Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery.

  8. Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling

    International Nuclear Information System (INIS)

    Lu Jun; Guerrero, Thomas M.; Munro, Peter; Jeung, Andrew; Chi, P.-C. M.; Balter, Peter; Zhu, X. Ronald; Mohan, Radhe; Pan Tinsu

    2007-01-01

    We have developed a new four-dimensional cone beam CT (4D-CBCT) on a Varian image-guided radiation therapy system, which has radiation therapy treatment and cone beam CT imaging capabilities. We adapted the speed of gantry rotation time of the CBCT to the average breath cycle of the patient to maintain the same level of image quality and adjusted the data sampling frequency to keep a similar level of radiation exposure to the patient. Our design utilized the real-time positioning and monitoring system to record the respiratory signal of the patient during the acquisition of the CBCT data. We used the full-fan bowtie filter during data acquisition, acquired the projection data over 200 deg of gantry rotation, and reconstructed the images with a half-scan cone beam reconstruction. The scan time for a 200-deg gantry rotation per patient ranged from 3.3 to 6.6 min for the average breath cycle of 3-6 s. The radiation dose of the 4D-CBCT was about 1-2 times the radiation dose of the 4D-CT on a multislice CT scanner. We evaluated the 4D-CBCT in scanning, data processing and image quality with phantom studies. We demonstrated the clinical applicability of the 4D-CBCT and compared the 4D-CBCT and the 4D-CT scans in four patient studies. The contrast-to-noise ratio of the 4D-CT was 2.8-3.5 times of the contrast-to-noise ratio of the 4D-CBCT in the four patient studies

  9. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator

    International Nuclear Information System (INIS)

    Du, Weiliang; Gao, Song

    2011-01-01

    Purpose: The isocenter accuracy of a linear accelerator is often assessed with star-shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston-Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change. Methods: A stationary ball-bearing phantom was imaged using multileaf collimator-shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball-bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified. Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator. Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.

  10. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Du, Weiliang; Gao, Song [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, 77030 (United States)

    2011-08-15

    Purpose: The isocenter accuracy of a linear accelerator is often assessed with star-shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston-Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change. Methods: A stationary ball-bearing phantom was imaged using multileaf collimator-shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball-bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified. Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator. Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.

  11. A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation

    DEFF Research Database (Denmark)

    Rowshanfarzad, P; Lynggaard Riis, Hans; Zimmermann, S J

    2015-01-01

    OBJECTIVE: In radiotherapy treatments, it is crucial to monitor the performance of linear accelerator (linac) components, including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested...... collimator leaf bank assemblies was around 1 mm. A meaningful correlation was found between the age of the linacs and their mechanical performance. Conclusions and Advances in knowledge: The method and software developed in this study provide a simple tool for effective investigation of the behaviour...

  12. Development of a superconducting rotating-gantry for heavy-ion therapy

    International Nuclear Information System (INIS)

    Iwata, Y.; Noda, K.; Murakami, T.; Shirai, T.; Furukawa, T.; Fujita, T.; Mori, S.; Mizushima, K.; Shouda, K.; Fujimoto, T.; Ogitsu, T.; Obana, T.; Amemiya, N.; Orikasa, T.; Takami, S.; Takayama, S.

    2013-01-01

    An isocentric superconducting rotating-gantry for heavy-ion therapy is being developed. This rotating gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180°, and is further capable of performing fast raster-scanning irradiation. For the magnets, combined-function superconducting-magnets are to be employed. All of the superconducting magnets have been designed, and their magnetic-field distributions were calculated by using a 3D electromagnetic-field solver. With the calculated magnetic-fields, beam-tracking simulations were performed to evaluate the field quality of the superconducting magnets. Beam profiles as well as phase-space distributions at the isocenter, as calculated by simulations, agreed well with those of linear beam-optics calculations, proving validity of the final design for the magnets. Three superconducting magnets were manufactured, and are being tested. In this paper, results of tracking simulations as well as test results for the superconducting magnets are presented

  13. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Sen; Li, Guangjun; Wang, Maojie; Jiang, Qinfeng; Zhang, Yingjie [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China); Wei, Yuquan, E-mail: yuquawei@vip.sina.com [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China)

    2013-07-01

    The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

  14. Rotational micro-CT using a clinical C-arm angiography gantry

    International Nuclear Information System (INIS)

    Patel, V.; Hoffmann, K. R.; Ionita, C. N.; Keleshis, C.; Bednarek, D. R.; Rudin, S.

    2008-01-01

    Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution ( 10 lp/mm) but to date have relied either on rotating object imaging or small bore geometry for small animal imaging, and thus are not used for clinical imaging. The authors report here the development and use of a 3D rotational micro-angiography (RMA) system created by mounting a micro-angiographic fluoroscope (MAF) [35 μm pixel, resolution >10 lp/mm, field of view (FOV)=3.6 cm] on a standard clinical FPD-based RA gantry (Infinix, Model RTP12303J-G9E, Toshiba Medical Systems Corp., Tustin, CA). RA image sequences are obtained using the MAF and reconstructed. To eliminate artifacts due to image truncation, lower-dose (compared to MAF acquisition) full-FOV (FFOV) FPD RA sequences (194 μm pixel, FOV=20 cm) were also obtained to complete the missing data. The RA gantry was calibrated using a helical bead phantom. To ensure high-quality high-resolution reconstruction, the high-resolution images from the MAF were aligned spatially with the lower-dose FPD images, and the pixel values in the FPD image data were scaled to match those of the MAF. Images of a rabbit with a coronary stent placed in an artery in the Circle of Willis were obtained and reconstructed. The MAF images appear well aligned with the FPD images (average correlation coefficient before and after alignment: 0.65 and 0.97, respectively) Greater details without any visible truncation artifacts are seen in 3D RMA (MAF-FPD) images than in those of the FPD alone. The FWHM of line profiles of stent struts (100 μm diameter) are approximately 192±21 and 313±38 μm for the 3D RMA and FPD data, respectively. In addition, for the dual-acquisition 3D RMA, FFOV FPD data need not be of the highest quality, and thus may be acquired at lower dose

  15. Beam-transport study of an isocentric rotating ion gantry with minimum number of quadrupoles

    International Nuclear Information System (INIS)

    Pavlovic, Marius; Griesmayer, Erich; Seemann, Rolf

    2005-01-01

    A beam-transport study of an isocentric gantry for ion therapy is presented. The gantry is designed with the number of quadrupoles down to the theoretical minimum, which is the feature published for the first time in this paper. This feature has been achieved without compromising the ion-optical functions of the beam-transport system that is capable of handling non-symmetric beams (beams with different emittances in vertical and horizontal plane), pencil-beam scanning, double-achromatic optics and beam-size control. Ion-optical properties of the beam-transport system are described, discussed and illustrated by computer simulations performed by the TRANSPORT-code

  16. Gantry cranes

    NARCIS (Netherlands)

    Luttekes, E.; Rijsenbrij, J.C.

    2003-01-01

    Portal crane (1) for loading and/or unloading a ship having a multiplicity of bays for containers (10) comprising a gantry (2) with travelling gear (5) for supporting the gantry on a quay (13), a boom supported by the gantry made up of a horizontal beam (6) and a jib (7) that during loading and/or

  17. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  18. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  19. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  20. An ion-optical design study of a carbon-ion rotating gantry with a superconducting final bending magnet

    International Nuclear Information System (INIS)

    Bokor, J.; Pavlovič, M.

    2016-01-01

    Ion-optical designs of an isocentric ion gantry with a compact curved superconducting final bending magnet are presented. The gantry is designed for transporting carbon-therapy beams with nominal kinetic energy of 400 MeV/u, which corresponds to the penetration range of C"6"+ beam in water of about 28 cm. In contrast to other existing designs, we present a “hybrid” beam transport system containing a single superconducting element – the last bending magnet. All other elements are based on conventional warm technology. Ion-optical properties of such a hybrid system are investigated in case of transporting non-symmetric (i.e. different emittance patterns in the horizontal and vertical plane) beams. Different conditions for transporting the non-symmetric beams are analyzed aiming at finding the optimal, i.e. the most compact, gantry version. The final gantry layout is presented including a 2D parallel scanning. The ion-optical and scanning properties of the final gantry design are described, discussed and illustrated by computer simulations performed by WinAGILE.

  1. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  2. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    International Nuclear Information System (INIS)

    Wiezorek, Tilo; Schubert, Kai; Wagner, Daniela; Wendt, Thomas G; Brachwitz, Tim; Georg, Dietmar; Blank, Eyck; Fotina, Irina; Habl, Gregor; Kretschmer, Matthias; Lutters, Gerd; Salz, Henning

    2011-01-01

    Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V 5Gy ). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V 5Gy values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. All IMRT delivery technologies with their associated TPS

  3. Computerized tomographic x-ray scanner system and gantry assembly

    International Nuclear Information System (INIS)

    Doyd, D.P.; Lanzara, G.

    1991-01-01

    This patent describes a scanner assembly. It comprises: a support head, a C-shaped gantry, means for supporting the gantry in the support head for rotating movement, an x-ray source mounted on one side of the gantry for independent movement with respect to a detector array along the gantry, the x-ray source projecting x-rays across the gantry, and a detector array mounted on the other side of a gantry for independent movement with respect to the x-ray source along the gantry, the detector array serving to receive the projected x-rays

  4. Impact of gantry rotation time on plan quality and dosimetric verification. Volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Pasler, Marlies; Wirtz, Holger; Lutterbach, Johannes [Gemeinschaftspraxis fuer Strahlentherapie Singen-Friedrichshafen, Singen (Germany)

    2011-12-15

    To compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. This retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle {sup copyright} planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom. VMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% {gamma} criterion, while in IMRT verification it was 98.8%. VMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

  5. Impact of gantry rotation time on plan quality and dosimetric verification. Volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Pasler, Marlies; Wirtz, Holger; Lutterbach, Johannes

    2011-01-01

    To compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. This retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle copyright planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom. VMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% γ criterion, while in IMRT verification it was 98.8%. VMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

  6. SU-F-T-457: A Filmless Method for Measurement of Couch Translation Per Gantry Rotation and Couch Speed for Tomotherapy Using ArcCheck

    International Nuclear Information System (INIS)

    Yang, B; Wong, R; Geng, H; Lam, W; Cheung, K; Yu, S

    2016-01-01

    Purpose: To develop a filmless methodology based on an ArcCheck for QA measurement of the couch translation per gantry rotation and couch speed of a Tomotherapy unit. Methods: Two test plans recommended by TG148 were chosen for this study. A helical plan with 1 cm field size opened the leaves for 180 degrees at the 2nd, 7th and 12th of total 13 rotations and was used to verify if the couch travelled the expected distance per gantry rotation. The other test plan was a static plan with the gantry at 0°, 1cm field width and constant couch movement speed of 0.5mm/s. It was used for couch speed measurement. The ArcCheck was isocentrically set up and recorded movie files which took a snapshot exposure every 50ms. Due to the spiral pattern of diodes distribution, when one of the diodes of the ArcCheck located at the beam center, the dose profile as measured by the row of diodes which surrounded the center diode should have a symmetrical pattern. We divided the profile into left half A and right half B. Then a shape parameter was defined as S=Σ|(A−B)|/Σ(A+B). By searching the local minimum of S parameter, the beam center at different time could be located. The machine trajectory log data were also collected and analyzed for comparison. Results: The mean value of measured couch translation and couch speed by ArcCheck had less than 0.05% deviation from the planned values. For couch speed measurement, our result showed a mean value of 0.5002 with an uncertainty ±0.0031, which agreed very well with both the plan setting of 0.5 mm/s and the machine log data of 0.5005 mm/s. Conclusion: Couch translation measured using ArcCheck is accurate and comparable to the film-based measurement. This filmless method also provides a convenient and independent way for measuring couch speed.

  7. SU-F-T-457: A Filmless Method for Measurement of Couch Translation Per Gantry Rotation and Couch Speed for Tomotherapy Using ArcCheck

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B; Wong, R; Geng, H; Lam, W; Cheung, K; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong, N/A, Hong Kong (China)

    2016-06-15

    Purpose: To develop a filmless methodology based on an ArcCheck for QA measurement of the couch translation per gantry rotation and couch speed of a Tomotherapy unit. Methods: Two test plans recommended by TG148 were chosen for this study. A helical plan with 1 cm field size opened the leaves for 180 degrees at the 2nd, 7th and 12th of total 13 rotations and was used to verify if the couch travelled the expected distance per gantry rotation. The other test plan was a static plan with the gantry at 0°, 1cm field width and constant couch movement speed of 0.5mm/s. It was used for couch speed measurement. The ArcCheck was isocentrically set up and recorded movie files which took a snapshot exposure every 50ms. Due to the spiral pattern of diodes distribution, when one of the diodes of the ArcCheck located at the beam center, the dose profile as measured by the row of diodes which surrounded the center diode should have a symmetrical pattern. We divided the profile into left half A and right half B. Then a shape parameter was defined as S=Σ|(A−B)|/Σ(A+B). By searching the local minimum of S parameter, the beam center at different time could be located. The machine trajectory log data were also collected and analyzed for comparison. Results: The mean value of measured couch translation and couch speed by ArcCheck had less than 0.05% deviation from the planned values. For couch speed measurement, our result showed a mean value of 0.5002 with an uncertainty ±0.0031, which agreed very well with both the plan setting of 0.5 mm/s and the machine log data of 0.5005 mm/s. Conclusion: Couch translation measured using ArcCheck is accurate and comparable to the film-based measurement. This filmless method also provides a convenient and independent way for measuring couch speed.

  8. Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

    International Nuclear Information System (INIS)

    Zhang, Shi-Zheng; Hu, Xiu-Hua; Zhang, Qiao-Wei; Huang, Wen-Xin

    2005-01-01

    The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups' t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm). (orig.)

  9. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  10. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio

    2016-01-01

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  11. Preliminary design study for a corkscrew gantry

    International Nuclear Information System (INIS)

    Koehler, A.M.

    1987-01-01

    For two years or more a group including the author has been working together to study some problems related to the design of a gentry system for flexible direction of a proton beam for clinical treatments. Some consideration was given to the classic gantry geometry. Attempting to reduce the radius of the gantry arm by reducing the drift space after the scattering foils led to an analysis of the significance of inverse square intensity effects. The conclusion reached is that a drift space of about 3 meters is required to preserve some skin sparing for larger targets. To circumvent this problem the scattering foils ere put somewhere inside or even before the gantry system, accepting the fact that magnet apertures would have to be increased. This gantry system has the interesting ability to produce oblong fields of excellent uniformity with reasonable efficiency, preferentially with the long axis of the field parallel to the axis of rotation. It was disappointing, however, to find that the overall size of the gantry with its counterweights remained very large. Another change in geometry was proposed therefore in order to reduce the space taken up by the gantry and its counterweight. The beam is bent 45 0 in the horizontal plane and then again by 45 0 so that it is pointing away from isocenter, but in the plan of rotation of the gantry. The beam is now bent in that plane of rotation until it is pointed at isocenter. This is accomplished by two bends of 135 0 each with a suitable drift space between them so that the beam is pointed vertically downward at isocenter. The three dimensional complexity of the beam trajectory led to the name Corkscrew Gantry

  12. 'Riesenrad' ion gantry for hadrontherapy: Part III

    International Nuclear Information System (INIS)

    Benedikt, M.; Bryant, P.; Holy, P.; Pullia, M.

    1999-01-01

    When using accelerator beams for cancer therapy, the three-dimensional freedom afforded by a gantry helps the treatment planner to spread out surface doses, avoid directions that intercept vital organs and irradiate a volume that is conformal with the tumour. The general preference is for an iso-centric gantry turning 360 deg. in the vertical plane around the patient bed with sufficient space to be able to orientate the patient through 360 deg. in the horizontal plane. For hadrontherapy, gantries are impressive structures of the order of 10 m in diameter and 100 ton in weight and to date only proton gantries have been demonstrated to operate satisfactorily. The increased magnetic rigidity of say carbon ions will make ion gantries more difficult and costly to build. For this reason, exo-centric gantries and, in particular the so-called 'Riesenrad' gantry with a single 90 deg. bending magnet, merit further attention. The power consumption is reduced and the heavy magnets with their counterbalance weight are reduced and are kept close to the axis. The treatment room, which is lighter, is positioned at a larger radius, but only the patient bed requires careful alignment. An optics module called a 'rotator' is needed to match an incoming dispersion vector to the gantry in order to have an achromatic beam at the patient. A practical design is described that assumes the beam is derived from a slow-extraction scheme in a synchrotron and that the beam sizes are controlled by modules in the transfer line. Magnetic scanning is integrated into the gantry optics for both transverse directions

  13. `Riesenrad' ion gantry for hadrontherapy: Part III

    Science.gov (United States)

    Benedikt, M.; Bryant, P.; Holy, P.; Pullia, M.

    1999-07-01

    When using accelerator beams for cancer therapy, the three-dimensional freedom afforded by a gantry helps the treatment planner to spread out surface doses, avoid directions that intercept vital organs and irradiate a volume that is conformal with the tumour. The general preference is for an iso-centric gantry turning 360° in the vertical plane around the patient bed with sufficient space to be able to orientate the patient through 360° in the horizontal plane. For hadrontherapy, gantries are impressive structures of the order of 10 m in diameter and 100 ton in weight and to date only proton gantries have been demonstrated to operate satisfactorily. The increased magnetic rigidity of say carbon ions will make ion gantries more difficult and costly to build. For this reason, exo-centric gantries and, in particular the so-called `Riesenrad' gantry with a single 90° bending magnet, merit further attention. The power consumption is reduced and the heavy magnets with their counterbalance weight are reduced and are kept close to the axis. The treatment room, which is lighter, is positioned at a larger radius, but only the patient bed requires careful alignment. An optics module called a `rotator' is needed to match an incoming dispersion vector to the gantry in order to have an achromatic beam at the patient. A practical design is described that assumes the beam is derived from a slow-extraction scheme in a synchrotron and that the beam sizes are controlled by modules in the transfer line. Magnetic scanning is integrated into the gantry optics for both transverse directions.

  14. Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy

    Energy Technology Data Exchange (ETDEWEB)

    Du Weiliang; Gao Song; Wang Xiaochun; Kudchadker, Rajat J. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2012-04-15

    Purpose: Gantry sag is one of the well-known sources of mechanical imperfections that compromise the spatial accuracy of radiation dose delivery. The objectives of this study were to quantify the gantry sag on multiple linear accelerators (linacs), to investigate a multileaf collimator (MLC)-based strategy to compensate for gantry sag, and to verify the gantry sag and its compensation with film measurements. Methods: The authors used the Winston-Lutz method to measure gantry sag on three Varian linacs. A ball bearing phantom was imaged with megavolt radiation fields at 10 deg. gantry angle intervals. The images recorded with an electronic portal imaging device were analyzed to derive the radiation isocenter and the gantry sag, that is, the superior-inferior wobble of the radiation field center, as a function of the gantry angle. The authors then attempted to compensate for the gantry sag by applying a gantry angle-specific correction to the MLC leaf positions. The gantry sag and its compensation were independently verified using film measurements. Results: Gantry sag was reproducible over a six-month measurement period. The maximum gantry sag was found to vary from 0.7 to 1.0 mm, depending on the linac and the collimator angle. The radiation field center moved inferiorly (i.e., away from the gantry) when the gantry was rotated from 0 deg. to 180 deg. After the MLC leaf position compensation was applied at 90 deg. collimator angle, the maximum gantry sag was reduced to <0.2 mm. The film measurements at gantry angles of 0 deg. and 180 deg. verified the inferior shift of the radiation fields and the effectiveness of MLC compensation. Conclusions: The results indicate that gantry sag on a linac can be quantitatively measured using a simple phantom and an electronic portal imaging device. Reduction of gantry sag is feasible by applying a gantry angle-specific correction to MLC leaf positions at 90 deg. collimator angle.

  15. Design of an achromatic and uncoupled medical gantry for radiation therapy

    International Nuclear Information System (INIS)

    Tsoupas, N.; Kayran, D.; Litvinenko, V.; MacKay, W.W.

    2011-01-01

    We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as long as the plane of the

  16. Volumetric modulated arc therapy: IMRT in a single gantry arc

    International Nuclear Information System (INIS)

    Otto, Karl

    2008-01-01

    In this work a novel plan optimization platform is presented where treatment is delivered efficiently and accurately in a single dynamically modulated arc. Improvements in patient care achieved through image-guided positioning and plan adaptation have resulted in an increase in overall treatment times. Intensity-modulated radiation therapy (IMRT) has also increased treatment time by requiring a larger number of beam directions, increased monitor units (MU), and, in the case of tomotherapy, a slice-by-slice delivery. In order to maintain a similar level of patient throughput it will be necessary to increase the efficiency of treatment delivery. The solution proposed here is a novel aperture-based algorithm for treatment plan optimization where dose is delivered during a single gantry arc of up to 360 deg. The technique is similar to tomotherapy in that a full 360 deg. of beam directions are available for optimization but is fundamentally different in that the entire dose volume is delivered in a single source rotation. The new technique is referred to as volumetric modulated arc therapy (VMAT). Multileaf collimator (MLC) leaf motion and number of MU per degree of gantry rotation is restricted during the optimization so that gantry rotation speed, leaf translation speed, and dose rate maxima do not excessively limit the delivery efficiency. During planning, investigators model continuous gantry motion by a coarse sampling of static gantry positions and fluence maps or MLC aperture shapes. The technique presented here is unique in that gantry and MLC position sampling is progressively increased throughout the optimization. Using the full gantry range will theoretically provide increased flexibility in generating highly conformal treatment plans. In practice, the additional flexibility is somewhat negated by the additional constraints placed on the amount of MLC leaf motion between gantry samples. A series of studies are performed that characterize the relationship

  17. Design of a "Riesenrad" Ion Gantry for Hadrontherapy

    CERN Document Server

    Reimoser, S

    2000-01-01

    The benefit of hadrontherapy can be maximized by offering the possibility to deliver the particle beam from any direction in space towards the patient with the help of a medical gantry. For carbon ions, their increased (magnetic) beam rigidity yields considerable structural difficulties and has so far prevented a practical realization of an ion gantry. The concept of a 'Riesenrad' ion gantry promises to provide an effective and efficient solution. The basic idea is to deflect the ion beam with a single 90° dipole, which rotates around the incoming beam axis, and direct it towards the eccentrically positioned patient cabin. Inside the cabin similar conditions as exist in a classical isocentric treatment room prevail. The practical design of such a Riesenrad gantry, its structural principles and its function are presented. The underlying beam optics and its integration into the mechanical structure are explained. Aspects of safety, and flexibility are discussed.

  18. The PSI Gantry 2: a second generation proton scanning gantry.

    Science.gov (United States)

    Pedroni, Eros; Bearpark, Ralph; Böhringer, Terence; Coray, Adolf; Duppich, Jürgen; Forss, Sven; George, David; Grossmann, Martin; Goitein, Gudrun; Hilbes, Christian; Jermann, Martin; Lin, Shixiong; Lomax, Antony; Negrazus, Marco; Schippers, Marco; Kotle, Goran

    2004-01-01

    PSI is still the only location in which proton therapy is applied using a dynamic beam scanning technique on a very compact gantry. Recently, this system is also being used for the application of intensity-modulated proton therapy (IMPT). This novel technical development and the success of the proton therapy project altogether have led PSI in Year 2000 to further expand the activities in this field by launching the project PROSCAN. The first step is the installation of a dedicated commercial superconducting cyclotron of a novel type. The second step is the development of a new gantry, Gantry 2. For Gantry 2 we have chosen an iso-centric compact gantry layout. The diameter of the gantry is limited to 7.5 m, less than in other gantry systems (approximately 10-12 m). The space in the treatment room is comfortably large, and the access on a fixed floor is possible any time around the patient table. Through the availability of a faster scanning system, it will be possible to treat the target volume repeatedly in the same session. For this purpose, the dynamic control of the beam intensity at the ion source and the dynamic variation of the beam energy will be used directly for the shaping of the dose.

  19. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    Energy Technology Data Exchange (ETDEWEB)

    Ju, S; Hong, C; Kim, M; Chung, K; Kim, J; Han, Y; Ahn, S; Chung, S; Shin, E; Shin, J; Kim, H; Kim, D; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

  20. Development and engineering design of a novel exocentric carbon-ion gantry for cancer therapy (the 'Riesenrad' gantry)

    International Nuclear Information System (INIS)

    Reimoser, S.A.

    2000-10-01

    The objective of the present thesis is to develop a novel gantry concept leading to a viable and efficient design for a carbon-ion gantry. Chapter 1 is meant to give some background information on radiation therapy and on the promises of ion treatment. Chapter 2 presents and summarizes existing gantry systems (in particular for protons) and briefly describes the experimental facilities for ion treatment in order to form an idea in what direction the design of an ion gantry might point. Chapter 3 is dedicated to the definition of the medical, beam-optical and mechanical constraints affecting the design of the ion gantry. The principal processes likely to take place inside the ion gantry are highlighted and the various technical systems and their interdependencies are investigated. As a result of these considerations it was decided to focus on the development of an exocentric gantry system for ion therapy, which was eventually named the 'Riesenrad' gantry. In contrast to conventional isocentric gantries, the main 90 o -bending magnet of the Riesenrad is placed on the axis of gantry rotation, hence minimizing the moment of inertia of the mobile structure and maximizing its rigidity. Several preliminary structural concepts for the Riesenrad gantry were generated, analyzed and compared in chapter 4. Finally, the variant featuring an independent telescopic cabin was chosen for further elaboration in a design phase (chapter 5). In the proposed variant, the bending magnet that sits on the axis and its counterweight (62 ton and 23 ton respectively) are supported by a central 'cage' of about 40 t. This gantry yields a higher efficiency in terms of structural weight to supported load compared to any other possible variant. A patient cabin is smoothly moved towards the desired treatment position by a system that is mechanically de-coupled from the central cage. Any desired position (that corresponds to a particular gantry angle) is achieved by vertical translation and

  1. SU-E-T-160: Characterization and Monitoring of Linear Accelerator Gantry Radiation Isocenter Motion

    International Nuclear Information System (INIS)

    Letourneau, D; Amin, N; Wang, K; Norrlinger, B; Jaffray, D; McNiven, A

    2015-01-01

    Purpose: To characterize the motion of the radiation isocenter, over time, as a function of gantry rotation for multiple linear accelerators (linacs). Two semi-automated image-based quality control (QC) test workflows were designed to achieve this goal. Methods: The full QC-test workflow for motion characterization consisted of acquiring 16 megavoltage images at 8 gantry angles of a ball-bearing suspended off the end of the couch. Performance constancy was assessed using a shortened QC-test workflow which consisted of imaging a cube phantom placed on the couch (5 images at 4 gantry angles). Both workflows use an image processing algorithm to determine the field center and phantom position on each image and computed radiation isocenter motion as a function of gantry angle. Motion was characterized for 9 linacs of same model and performance monitored for 2 months on 3 linacs. Results: The maximum isocenter motion determined with the full-workflow for 9 linacs was within 0.38–0.79 mm. The shortened-workflow usually agreed within 0.1 mm with the full-workflow and the time required for these methods was about 4 and 15 min, respectively. For all linacs, the isocenter motion perpendicular to the gantry rotation plane followed a consistent pattern with maximum amplitude of 0.36–0.59 mm. In the gantry rotation plane, the variation among linacs was higher and the beam axis described a circle of up to 0.6 mm radius around the gantry axis of rotation (2 linacs). The radiation isocenter motion was stable as a function of time for the monitored linacs and was within ±0.1 mm of the average. Conclusion: Radiation isocenter motion parallel and perpendicular to the gantry rotation plane was characterized. In the gantry rotation plane, beam spot positioning adjustment might be used to reduce the observed radiation isocenter motion. A shortened-workflow was designed and enables performance monitoring over time

  2. Motion planning for gantry mounted manipulators

    DEFF Research Database (Denmark)

    Olsen, Anders Lau; Petersen, Henrik Gordon

    2007-01-01

    We present a roadmap based planner for finding robot motions for gantry mounted manipulators for a line welding application at Odense Steel Shipyard (OSS). The robot motions are planned subject to constraints on when the gantry may be moved. We show that random sampling of gantry configurations...

  3. Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences; Darstellung der Herzkranzgefaesse im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Heuschmid, M.; Kuettner, A.; Kopp, A.F.; Claussen, C.D. [Abt. Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Flohr, T.; Schaller, S.; Hartung, A.; Ohnesorge, B. [Siemens Medical Solutions, Forchheim (Germany); Wildberger, J.E. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum (RWTH) Aachen (Germany); Lell, M.; Baum, U. [Abt. Innere Medizin IV (Kardiologie), Universitaetsklinikum Tuebingen (Germany); Schroeder, S. [Inst. fuer Diagnostische Radiologie, Universitaetsklinikum Erlangen (Germany)

    2002-06-01

    Purpose: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. Materials and Methods: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a {beta}-Blocker, the heart rate was between 55 and 67 bpm. Results: The scan time for calcium score was 12s, for CTA 18s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. Conclusion: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated. (orig.) [German] Ziel: Darstellung erster Ergebnisse zur Bildqualitaet eines neuen 16-Zeilen Multidetektor-Computertomographen (MDCT) bei der Diagnostik der koronaren Herzerkrankung (KHK) und hochgradiger Stenosen der Herzkranzgefaesse. Material und Methode: Mit einem neuen 16-Zeilen-Computertomographen (SOMATOM Sensation 16, Siemens, Forchheim) wurde bei 4 Patienten zum Ausschluss oder

  4. "Riesenrad" Ion Gantry for Hadron Therapy, 3

    OpenAIRE

    Benedikt, Michael; Bryant, P J; Holy, P; Pullia, M

    1999-01-01

    When using accelerator beams for cancer therapy, the three-dimensional freedom afforded by a gantry helps the treatment planner to spread out surface doses, avoid directions that intercept vital organs and irradiate a volume that is conformal with the tumour. The general preference is for an iso-centric gantry turning 360° in the vertical plane around the patient bed with sufficient space to be able to orientate the patient through 360° in the horizontal plane. For hadrontherapy, gantries are...

  5. A new irradiation unit constructed of self-moving gantry-CT and linac

    International Nuclear Information System (INIS)

    Kuriyama, Kengo; Onishi, Hiroshi; Sano, Naoki; Komiyama, Takafumi; Aikawa, Yoshihito; Tateda, Yoshihito; Araki, Tsutomu; Uematsu, Minoru

    2003-01-01

    Purpose: To improve reproducibility in stereotactic irradiation (STI) without using noninvasive immobilization devices or body frames, we have developed an integrated computed tomography (CT)-linac irradiation system connecting CT scanner and linac via a common treatment couch. Methods and Materials: This system consists of a linac, a CT scanner, and a common treatment couch. The linac and the CT gantry are positioned on opposite ends of the couch so that, by rotating the treatment couch, linac radiotherapy or CT scanning can be performed. The rotational axis of the linac gantry is coaxial with that of the CT gantry, and the position of the linac isocenter on the couch matches the origin of the coordinate system for CT scanning when the couch is rotated 180 degree sign toward the CT side. Instead of the couch moving into the gantry, as in conventional CT, in this case the table is fixed and scanning is accomplished by moving the gantry. We evaluated the rotational accuracy of the common couch and the scan-position accuracy of the self-moving gantry CT. Results: The positional accuracy of the common couch was 0.20, 0.18, and 0.39 mm in the lateral, longitudinal, and vertical directions, respectively. The scan-position accuracy of the CT gantry was less than 0.4 mm in the lateral, longitudinal, and vertical directions. Conclusion: This irradiation system has a high accuracy and is useful for noninvasive STI and for verification of the position of a target in three-dimensional conformal radiotherapy

  6. "Riesenrad" Ion Gantry for Hadron Therapy, 3

    CERN Document Server

    Benedikt, Michael; Holy, P; Pullia, M

    1999-01-01

    When using accelerator beams for cancer therapy, the three-dimensional freedom afforded by a gantry helps the treatment planner to spread out surface doses, avoid directions that intercept vital organs and irradiate a volume that is conformal with the tumour. The general preference is for an iso-centric gantry turning 360° in the vertical plane around the patient bed with sufficient space to be able to orientate the patient through 360° in the horizontal plane. For hadrontherapy, gantries are impressive structures of the order of 10 m in diameter and 100 tons in weight and to date only proton gantries have been demonstrated to operate satisfactorily. The increased magnetic rigidity of say carbon ions will make ion gantries more difficult and costly to build. For this reason, exo-centric gantries and, in particular the so-called 'Riesenrad' gantry with a single 90° bending magnet, merit further attention. The power consumption is reduced and the heavy magnets with their counterbalance weight are reduced and...

  7. Emplacement Gantry Gap Analysis Study

    International Nuclear Information System (INIS)

    Thornley, R.

    2005-01-01

    To date, the project has established important to safety (ITS) performance requirements for structures, systems, and components (SSCs) based on the identification and categorization of event sequences that may result in a radiological release. These performance requirements are defined within the ''Nuclear Safety Design Bases for License Application'' (NSDB) (BSC 2005 [DIRS 171512], Table A-11). Further, SSCs credited with performing safety functions are classified as ITS. In turn, assurance that these SSCs will perform as required is sought through the use of consensus codes and standards. This gap analysis is based on the design completed for license application only. Accordingly, identification of ITS SSCs beyond those defined within the NSDB are based on designs that may be subject to further development during detail design. Furthermore, several design alternatives may still be under consideration to satisfy certain safety functions, and final selection will not be determined until further design development has occurred. Therefore, for completeness, alternative designs currently under consideration will be discussed throughout this study. This gap analysis will evaluate each code and standard identified within the ''Emplacement Gantry ITS Standards Identification Study'' (BSC 2005 [DIRS 173586]) to ensure each ITS performance requirement is fully satisfied. When a performance requirement is not fully satisfied, a gap is highlighted. This study will identify requirements to supplement or augment the code or standard to meet performance requirements. Further, this gap analysis will identify nonstandard areas of the design that will be subject to a design development plan. Nonstandard components and nonstandard design configurations are defined as areas of the design that do not follow standard industry practices or codes and standards. Whereby, assurance that an SSC will perform as required may not be readily sought though the use of consensus standards. This

  8. Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle

    International Nuclear Information System (INIS)

    Clarke, M F; Budgell, G J

    2008-01-01

    Amorphous silicon electronic portal imaging devices (EPIDs) are used to perform routine quality control (QC) checks on the multileaf collimators (MLCs) at this centre. Presently, these checks are performed at gantry angle 0 0 and are considered to be valid for all other angles. Since therapeutic procedures regularly require the delivery of MLC-defined fields to the patient at a wide range of gantry angles, the accuracy of the QC checks at other gantry angles has been investigated. When the gantry is rotated to angles other than 0 0 it was found that the apparent pixel size measured using the EPID varies up to a maximum value of 0.0015 mm per pixel due to a sag in the EPID of up to 9.2 mm. A correction factor was determined using two independent methods at a range of gantry angles between 0 deg. and 360 deg. The EPID was used to measure field sizes (defined by both x-jaws and MLC) at a range of gantry angles and, after this correction had been applied, any residual gravitational sag was studied. It was found that, when fields are defined by the x-jaws and y-back-up jaws, no errors of greater than 0.5 mm were measured and that these errors were no worse when the MLC was used. It was therefore concluded that, provided the correction is applied, measurements of the field size are, in practical terms, unaffected by gantry angle. Experiments were also performed to study how the reproducibility of individual leaves is affected by gantry angle. Measurements of the relative position of each individual leaf (minor offsets) were performed at a range of gantry angles and repeated three times. The position reproducibility was defined by the RMS error in the position of each leaf and this was found to be 0.24 mm and 0.21 mm for the two leaf banks at a gantry angle of 0 0 . When measurements were performed at a range of gantry angles, these reproducibility values remained within 0.09 mm and 0.11 mm. It was therefore concluded that the calibration of the Elekta MLC is stable at

  9. Is medical linac suitable for high-precision stereotactic irradiation? Investigations in geometrical accuracies of gantry and couch

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Kitamura, Masayuki; Kawaguchi, Osamu; Shigematsu, Naoyuki; Ando, Yutaka; Kubo, Atsushi; Ohira, Takayuki; Tonai, Takenori; Kawase, Takeshi.

    1998-01-01

    Linac-based radiosurgery has many advantages over the gamma knife, including low initial cost and no need of source replacement. On the other hand, most of the medical linacs currently in use were not originally designed to be applied for radiosurgery, and, therefore, careful quality assurance programs are required. In the gantry-head of a linac, a small CCD video camera is mounted in a position optically identical to that of the x-ray source. The video signal from the camera was digitalized to be evaluated for geometrical errors. A metal ball fixed to the stereotactic base frame via XYZ-sliding rods was used as a simulated target. Displacements of the target from the isocenter were measured during rotation of the gantry. Displacements in the gantry-rotation plane were satisfactorily small, while those perpendicular to it were maximal at gantry position angles of 0deg and 180deg. This error might be caused by gravitational vending of the heavy gantry head. Although other major errors of the linac were within one millimeter, the center of coach rotation around the isocenter did not coincide with the center of gantry rotation, probably owing to gravitational vending. Special care should be taken when very small collimators are employed. (author)

  10. SU-G-TeP2-04: Comprehensive Machine Isocenter Evaluation with Separation of Gantry, Collimator, and Table Variables

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, S [Southeast Missouri Hospital, Cape Girardeau, MO (United States); Clements, C [Radiological Imaging Technology, Colorado Springs, CO (United States); Hyer, D; Nixon, E [University Of Iowa, Iowa City, IA (United States); Martin, E; Wang, B [University of Louisville, Louisville, KY (United States); Jani, S [Sharp Memorial Hospital, San Diego, CA (United States); Gossman, M [Tri-State Regional Cancer Center, Ashland, KY (United States)

    2016-06-15

    Purpose: To develop and demonstrate application of a method that characterizes deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter as a function of gantry, collimator, and table variables. Methods: A set of Winston-Lutz ball-bearing images was used to determine the gantry radiation isocenter as the midrange of deviation values resulting from gantry and collimator rotation. Also determined were displacement of table axis from gantry isocenter and recommended table axis adjustment. The method, previously reported, has been extended to include the effect of collimator walkout by obtaining measurements with 0 and 180 degree collimator rotation for each gantry angle. Twelve images were used to characterize the volumetric isocenter for the full range of available gantry, collimator, and table rotations. Results: Three Varian True Beam, two Elekta Infinity and four Versa HD linacs at five institutions were tested using identical methodology. Varian linacs exhibited substantially less deviation due to head sag than Elekta linacs (0.4 mm vs. 1.2 mm on average). One linac from each manufacturer had additional isocenter deviation of 0.3 to 0.4 mm due to jaw instability with gantry and collimator rotation. For all linacs, the achievable isocenter tolerance was dependent on adjustment of collimator position offset, transverse position steering, and alignment of the table axis with gantry isocenter, facilitated by these test results. The pattern and magnitude of table axis wobble vs. table angle was reproducible and unique to each machine. Conclusion: This new method provides a comprehensive set of isocenter deviation values including all variables. It effectively facilitates minimization of deviation between beam center and target (ball-bearing) position. This method was used to quantify the effect of jaw instability on isocenter deviation and to identify the offending jaw. The test is suitable for incorporation into a routine machine QA

  11. Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging.

    Science.gov (United States)

    Rowshanfarzad, Pejman; Sabet, Mahsheed; O'Connor, Daryl J; McCowan, Peter M; McCurdy, Boyd M C; Greer, Peter B

    2012-02-01

    Electronic portal imaging devices (EPIDs) have been studied and used for pretreatment and in-vivo dosimetry applications for many years. The application of EPIDs for dosimetry in arc treatments requires accurate characterization of the mechanical sag of the EPID and gantry during rotation. Several studies have investigated the effects of gravity on the sag of these systems but each have limitations. In this study, an easy experiment setup and accurate algorithm have been introduced to characterize and correct for the effect of EPID and gantry sag during arc delivery. Three metallic ball bearings were used as markers in the beam: two of them fixed to the gantry head and the third positioned at the isocenter. EPID images were acquired during a 360° gantry rotation in cine imaging mode. The markers were tracked in EPID images and a robust in-house developed MATLAB code was used to analyse the images and find the EPID sag in three directions as well as the EPID + gantry sag by comparison to the reference gantry zero image. The algorithm results were then tested against independent methods. The method was applied to compare the effect in clockwise and counter clockwise gantry rotations and different source-to-detector distances (SDDs). The results were monitored for one linear accelerator over a course of 15 months and six other linear-accelerators from two treatment centers were also investigated using this method. The generalized shift patterns were derived from the data and used in an image registration algorithm to correct for the effect of the mechanical sag in the system. The Gamma evaluation (3%, 3 mm) technique was used to investigate the improvement in alignment of cine EPID images of a fixed field, by comparing both individual images and the sum of images in a series with the reference gantry zero image. The mechanical sag during gantry rotation was dependent on the gantry angle and was larger in the in-plane direction, although the patterns were not

  12. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device.

    Science.gov (United States)

    Rowshanfarzad, Pejman; Häring, Peter; Riis, Hans L; Zimmermann, Sune J; Ebert, Martin A

    2015-01-01

    In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. The EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines.

  13. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

    Directory of Open Access Journals (Sweden)

    Rowshanfarzad P

    2015-11-01

    Full Text Available Pejman Rowshanfarzad,1 Peter Häring,2 Hans L Riis,3 Sune J Zimmermann,3 Martin A Ebert1,4 1School of Physics, The University of Western Australia, Crawley, WA, Australia; 2German Cancer Research Center (DKFZ, Medical Physics in Radiation Oncology, Heidelberg, Germany; 3Radiofysisk Laboratorium, Odense University Hospital, Odense C, Denmark; 4Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia Background: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. Methods: The EPID sag, gantry sag, changes in source-to-detector distance (SDD, EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. Results: The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. Conclusion: The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines. Keywords: linac, Siemens, arc, sag, EPID, gantry

  14. SU-E-T-130: Are Proton Gantries Needed? An Analysis of 4332 Patient Proton Gantry Treatment Plans From the Past 10 Years

    International Nuclear Information System (INIS)

    Yan, S; Lu, H; Flanz, J; Depauw, N; Adams, J; Gorissen, BL; Wang, Y; Daartz, J; Bortfeld, T

    2015-01-01

    Purpose: To ascertain the necessity of a proton gantry, as compared to the feasibility of using a horizontal fixed proton beam-line for treatment with advanced technology. Methods: To calculate the percentage of patients that can be treated with a horizontal fixed beam-line instead of a gantry, we analyze the distributions of beam orientations of our proton gantry patients treated over the past 10 years. We identify three horizontal fixed beam geometries (FIXED, BEND and MOVE) with the patient in lying and/or sitting positions. The FIXED geometry includes only table/chair rotations and translations. In BEND, the beam can be bent up/down for up to 20 degrees. MOVE allows for patient head/body angle adjustment. Based on the analysis, we select eight patients whose plan involves beams which are still challenging to achieve with a horizontal fixed beam. These beams are removed in the pencil beam scanning (PBS) plan optimized for the fixed beam-line (PBS-fix). We generate non-coplanar PBS-gantry plans for comparison, and perform a robustness analysis. Results: The percentage of patients with head-and-neck/brain tumors that can be treated with horizontal fixed beam is 44% in FIXED, 70% in 20-degrees BEND, and 100% in 90-degrees MOVE. For torso regions, 99% of the patients can be treated in 20-degree BEND. The target coverage is more homogeneous with PBS-fix plans compared to the clinical scattering treatment plans. The PBS-fix plans reduce the mean dose to organs-at-risk by a factor of 1.1–28.5. PBS-gantry plans are as good as PBS-fix plans, sometimes marginally better. Conclusion: The majority of the beam orientations can be realized with a horizontal fixed beam-line. Challenging non-coplanar beams can be eliminated with PBS delivery. Clinical implementation of the proposed fixed beam-line requires use of robotic patient positioning, further developments in immobilization, and image guidance. However, our results suggest that fixed beam-lines can be as effective as

  15. SU-E-T-130: Are Proton Gantries Needed? An Analysis of 4332 Patient Proton Gantry Treatment Plans From the Past 10 Years

    Energy Technology Data Exchange (ETDEWEB)

    Yan, S; Lu, H; Flanz, J; Depauw, N; Adams, J; Gorissen, BL; Wang, Y; Daartz, J; Bortfeld, T [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To ascertain the necessity of a proton gantry, as compared to the feasibility of using a horizontal fixed proton beam-line for treatment with advanced technology. Methods: To calculate the percentage of patients that can be treated with a horizontal fixed beam-line instead of a gantry, we analyze the distributions of beam orientations of our proton gantry patients treated over the past 10 years. We identify three horizontal fixed beam geometries (FIXED, BEND and MOVE) with the patient in lying and/or sitting positions. The FIXED geometry includes only table/chair rotations and translations. In BEND, the beam can be bent up/down for up to 20 degrees. MOVE allows for patient head/body angle adjustment. Based on the analysis, we select eight patients whose plan involves beams which are still challenging to achieve with a horizontal fixed beam. These beams are removed in the pencil beam scanning (PBS) plan optimized for the fixed beam-line (PBS-fix). We generate non-coplanar PBS-gantry plans for comparison, and perform a robustness analysis. Results: The percentage of patients with head-and-neck/brain tumors that can be treated with horizontal fixed beam is 44% in FIXED, 70% in 20-degrees BEND, and 100% in 90-degrees MOVE. For torso regions, 99% of the patients can be treated in 20-degree BEND. The target coverage is more homogeneous with PBS-fix plans compared to the clinical scattering treatment plans. The PBS-fix plans reduce the mean dose to organs-at-risk by a factor of 1.1–28.5. PBS-gantry plans are as good as PBS-fix plans, sometimes marginally better. Conclusion: The majority of the beam orientations can be realized with a horizontal fixed beam-line. Challenging non-coplanar beams can be eliminated with PBS delivery. Clinical implementation of the proposed fixed beam-line requires use of robotic patient positioning, further developments in immobilization, and image guidance. However, our results suggest that fixed beam-lines can be as effective as

  16. SU-E-T-64: CG-Based Radiation Therapy Simulator with Physical Modeling for Avoidance of Collisions Between Gantry and Couch Or Patient

    International Nuclear Information System (INIS)

    Yamanouchi, M; Arimura, H; Yuda, I

    2014-01-01

    Purpose: It is time-consuming and might cause re-planning to check couch-gantry and patient-gantry collisions on a radiotherapy machine when using couch rotations for non-coplanar beam angles. The aim of this study was to develop a computer-graphics (CG)-based radiation therapy simulator with physical modeling for avoidance of collisions between gantry and couch or patient on a radiotherapy machine. Methods: The radiation therapy simulator was three-dimensionally constructed including a radiotherapy machine (Clinac iX, Varian Medical Systems), couch, and radiation treatment room according to their designs by using a physical-modeling-based computer graphics software (Blender, free and open-source). Each patient was modeled by applying a surface rendering technique to their planning computed tomography (CT) images acquired from 16-slice CT scanner (BrightSpeed, GE Healthcare). Immobilization devices for patients were scanned by the CT equipment, and were rendered as the patient planning CT images. The errors in the collision angle of the gantry with the couch or patient between gold standards and the estimated values were obtained by fixing the gantry angle for the evaluation of the proposed simulator. Results: The average error of estimated collision angles to the couch head side was -8.5% for gantry angles of 60 to 135 degree, and -5.5% for gantry angles of 225 to 300 degree. Moreover, the average error of estimated collision angles to the couch foot side was -1.1% for gantry angles of 60 to 135 degree, and 1.4% for gantry angles of 225 to 300 degree. Conclusion: The CG-based radiation therapy simulator could make it possible to estimate the collision angle between gantry and couch or patient on the radiotherapy machine without verifying the collision angles in the radiation treatment room

  17. Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

    International Nuclear Information System (INIS)

    Wang, Ning; Ghebremedhin, Abiel; Patyal, Baldev

    2015-01-01

    Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm 3 Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on the

  18. Ports Initiative

    Science.gov (United States)

    EPA's Ports Initiative works in collaboration with the port industry, communities, and government to improve environmental performance and increase economic prosperity. This effort helps people near ports breath cleaner air and live better lives.

  19. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  20. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  1. VMATc: VMAT with constant gantry speed and dose rate

    International Nuclear Information System (INIS)

    Peng, Fei; Romeijn, H Edwin; Epelman, Marina A; Jiang, Steve B

    2015-01-01

    This article considers the treatment plan optimization problem for Volumetric Modulated Arc Therapy (VMAT) with constant gantry speed and dose rate (VMATc). In particular, we consider the simultaneous optimization of multi-leaf collimator leaf positions and a constant gantry speed and dose rate. We propose a heuristic framework for (approximately) solving this optimization problem that is based on hierarchical decomposition. Specifically, an iterative algorithm is used to heuristically optimize dose rate and gantry speed selection, where at every iteration a leaf position optimization subproblem is solved, also heuristically, to find a high-quality plan corresponding to a given dose rate and gantry speed. We apply our framework to clinical patient cases, and compare the resulting VMATc plans to idealized IMRT, as well as full VMAT plans. Our results suggest that VMATc is capable of producing treatment plans of comparable quality to VMAT, albeit at the expense of long computation time and generally higher total monitor units. (paper)

  2. Principal Ports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Principal Ports are defined by port limits or US Army Corps of Engineers (USACE) projects, these exclude non-USACE projects not authorized for publication. The...

  3. EMPLACEMENT GANTRY ITS STANDARDS IDENTIFICATION STUDY

    International Nuclear Information System (INIS)

    Voegele, M.

    2005-01-01

    To date, the project has established ITS performance requirements for SSCs based on identification and categorization of event sequences that may result in a radiological release. These performance requirements are defined within the NSDB. Further, SSCs credited with performing safe functions are classified as ITS. In turn, perform confirmation for these SSCs is sought through the use of consensus code and standards. The purpose of this study is to identify applicable codes and standards for the WP Emplacement Gantry ITS SSCs. Further, this study will form the basis for selection and the extent of applicability of each code and standard. This study is based on the design development completed for LA only. Accordingly, identification of ITS SSCs beyond those defined within the NSDB are based on designs that may be subject to further development during detail design. Furthermore, several design alternatives may still be under consideration to satisfy certain safety functions, and that final selection will not be determined until further design development has occurred. Therefore, for completeness, throughout this study alternative designs currently under considered will be discussed. Further, the results of this study will be subject to evaluation as part of a follow-on GAP analysis study. Based on the results of this study the GAP analysis will evaluate each code and standard to ensure each ITS performance requirement is fully satisfied. When a performance requirement is not fully satisfied a ''gap'' is highlighted. Thereafter, the study will identify supplemental requirements to augment the code or standard to meet performance requirements. Further, the GAP analysis will identify non-standard areas of the design that will be subject to a Development Plan. Non-standard components and non-standard design configurations are defined as areas of the design that do not follow standard industry practices or codes and standards. Whereby, performance confirmation cannot be

  4. Carbon/proton therapy: A novel gantry design

    Directory of Open Access Journals (Sweden)

    D. Trbojevic

    2007-05-01

    Full Text Available A major expense and design challenge in carbon/proton cancer therapy machines are the isocentric gantries. The transport elements of the carbon/proton gantry are presently made of standard conducting dipoles. Because of their large weight, of the order of ∼100   tons, the total weight of the gantry with support structure is ∼600   tons. The novel gantry design that is described here is made of fixed field superconducting magnets, thus dramatically reducing magnet size and weight compared to conventional magnets. In addition, the magnetic field is constant throughout the whole energy region required for tumor treatment. Particles make very small orbit offsets, passing through the beam line. The beam line is built of combined-function dipoles such as a nonscaling fixed field alternating gradient (NS-FFAG structure. The very large momentum acceptance NS-FFAG comes from very strong focusing and very small dispersion. The NS-FFAG small magnets almost completely filled the beam line. They first make a quarter (or close to a quarter of an arc bending upward and an additional half of a circle beam line finishing so that the beam is pointed towards the patient. At the end of the gantry, additional magnets with a fast response are required to allow radial scanning and to provide the required position and spot size. The fixed field combined-function magnets for the carbon gantry could be made of superconducting magnets by using low temperature superconducting cable or by using high temperature superconductors.

  5. Mechanical analysis and optimisation of large and highly-loaded bearing rollers For the "Riesenrad" Ion Gantry

    CERN Document Server

    Reimoser, S A

    2000-01-01

    A carbon ion gantry would allow the irradiation of cancer patients with carbon ions from any direction in space best suited for therapy. Till today, such a machine has not been built due to the expected size, mass and cost. A novel design, called "Riesenrad" ion gantry, promises to provide a competitive solution. The central part of the Riesenrad, which can rotate ± 90°, is supported (statically determinate) on pendular bearing units with two rollers each. High precision requirements for the structure rule out any plastic deformations in the area of contact. The present report describes the design of the highly-loaded rollers. In order to achieve a large contact area and a uniform distribution of contact stresses, a "barrel shape" for the rollers is proposed. An analysis using the finite element method (FEM) was performed to optimise the roller design, namely to establish the required crown roll (camber radius).

  6. Roll and pitch set-up errors during volumetric modulated arc delivery: can adapting gantry and collimator angles compensate?

    Science.gov (United States)

    Hoffmans-Holtzer, Nienke A; Hoffmans, Daan; Dahele, Max; Slotman, Ben J; Verbakel, Wilko F A R

    2015-03-01

    The purpose of this work was to investigate whether adapting gantry and collimator angles can compensate for roll and pitch setup errors during volumetric modulated arc therapy (VMAT) delivery. Previously delivered clinical plans for locally advanced head-and-neck (H&N) cancer (n = 5), localized prostate cancer (n = 2), and whole brain with simultaneous integrated boost to 5 metastases (WB + 5M, n = 1) were used for this study. Known rigid rotations were introduced in the planning CT scans. To compensate for these, in-house software was used to adapt gantry and collimator angles in the plan. Doses to planning target volumes (PTV) and critical organs at risk (OAR) were calculated with and without compensation and compared with the original clinical plan. Measurements in the sagittal plane in a polystyrene phantom using radiochromic film were compared by gamma (γ) evaluation for 2 H&N cancer patients. For H&N plans, the introduction of 2°-roll and 3°-pitch rotations reduced mean PTV coverage from 98.7 to 96.3%. This improved to 98.1% with gantry and collimator compensation. For prostate plans respective figures were 98.4, 97.5, and 98.4%. For WB + 5M, compensation worked less well, especially for smaller volumes and volumes farther from the isocenter. Mean comparative γ evaluation (3%, 1 mm) between original and pitched plans resulted in 86% γ plan restored the mean comparison to 96% γ < 1. Preliminary data suggest that adapting gantry and collimator angles is a promising way to correct roll and pitch set-up errors of < 3° during VMAT for H&N and prostate cancer.

  7. New system for linear accelerator radiosurgery with a gantry-mounted video camera

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Kitamura, Masayuki; Kawaguchi, Osamu; Ohira, Takayuki; Ogawa, Kouichi; Ando, Yutaka; Nakamura, Kayoko; Kubo, Atsushi

    1998-01-01

    Purpose: We developed a positioning method that does not depend on the positioning mechanism originally annexed to the linac and investigated the positioning errors of the system. Methods and Materials: A small video camera was placed at a location optically identical to the linac x-ray source. A target pointer comprising a convex lens and bull's eye was attached to the arc of the Leksell stereotactic system so that the lens would form a virtual image of the bull's eye (virtual target) at the position of the center of the arc. The linac gantry and target pointer were placed at the side and top to adjust the arc center to the isocenter by referring the virtual target. Coincidence of the target and the isocenter could be confirmed in any combination of the couch and gantry rotation. In order to evaluate the accuracy of the positioning, a tungsten ball was attached to the stereotactic frame as a simulated target, which was repeatedly localized and repositioned to estimate the magnitude of the error. The center of the circular field defined by the collimator was marked on the film. Results: The differences between the marked centers of the circular field and the centers of the shadow of the simulated target were less than 0.3 mm

  8. A novel constrained H2 optimization algorithm for mechatronics design in flexure-linked biaxial gantry.

    Science.gov (United States)

    Ma, Jun; Chen, Si-Lu; Kamaldin, Nazir; Teo, Chek Sing; Tay, Arthur; Mamun, Abdullah Al; Tan, Kok Kiong

    2017-11-01

    The biaxial gantry is widely used in many industrial processes that require high precision Cartesian motion. The conventional rigid-link version suffers from breaking down of joints if any de-synchronization between the two carriages occurs. To prevent above potential risk, a flexure-linked biaxial gantry is designed to allow a small rotation angle of the cross-arm. Nevertheless, the chattering of control signals and inappropriate design of the flexure joint will possibly induce resonant modes of the end-effector. Thus, in this work, the design requirements in terms of tracking accuracy, biaxial synchronization, and resonant mode suppression are achieved by integrated optimization of the stiffness of flexures and PID controller parameters for a class of point-to-point reference trajectories with same dynamics but different steps. From here, an H 2 optimization problem with defined constraints is formulated, and an efficient iterative solver is proposed by hybridizing direct computation of constrained projection gradient and line search of optimal step. Comparative experimental results obtained on the testbed are presented to verify the effectiveness of the proposed method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  10. Markerless PET motion correction: tracking in narrow gantries through optical fibers

    DEFF Research Database (Denmark)

    Jensen, Rasmus Ramsbøl; Olesen, Oline Vinter; Benjaminsen, Claus

    2015-01-01

    be accurate while only adding minimal complexity to the workflow. We present: Tracoline 2.0, a surface scanner prototype, which allows for markerless tracking in the clinic. The system uses structured light through optical fibre bundles, which easily fit in narrow gantries. The optical fibres also makes...... the system compatible with magnetic resonance (MR) imaging since all the electronics are moved away from the scanner. We demonstrate the system in a positron emission tomography (PET) study using the Siemens high resolution research tomography (HRRT). With two Ge/Ga-68 line sources fitted in a mannequin head...... for rotations up to ±25º. Based on the tracking results the PET frames were also successfully corrected for motion by aligning 10 s frames without motion for the stepwise experiment and aligning 1 s frames for the experiment with continuous motion. We have demonstrated and evaluated a system for markerless...

  11. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.

    Science.gov (United States)

    Zhang, Yunkai; Hsi, Wen C; Chu, James C H; Bernard, Damian B; Abrams, Ross A

    2005-01-01

    The effect of gantry rotation on beam profiles of photon and electron beams is an important issue in quality assurance for radiotherapy. To address variations in the profiles of photon and electron beams at different gantry angles, a Dynamic Phantom scanner composed of a 20 x 12 x 6 cm3 scanning Lucite block was designed as a cross-beam-profile scanner. To our knowledge, differences between scanned profiles acquired at different gantry angles with a small size Lucite block and those acquired a full-size (60 x 60 x 50 cm3) water phantom have not been previously investigated. We therefore performed a feasibility study for a first prototype Dynamic Phantom scanner without a gantry attachment mount. Radiation beams from a Varian LINAC 21EX and 2100C were used. Photon beams (6 MV and 18 MV) were shaped by either collimator jaws or a Varian 120 Multileaf (MLC) collimator, and electron beams (6 MeV, 12 MeV, and 20 MeV) were shaped by a treatment cone. To investigate the effect on profiles by using a Lucite block, a quantitative comparison of scanned profiles with the Dynamic Phantom and a full-size water phantom was first performed at a 0 degrees gantry angle for both photon and electron beams. For photon beam profiles defined by jaws at 1.0 cm and 5.0 cm depths of Lucite (i.e., at 1.1 cm and 5.7 cm depth of water), a good agreement (less than 1% variation) inside the field edge was observed between profiles scanned with the Dynamic Phantom and with a water phantom. The use of Lucite in the Dynamic Phantom resulted in reduced penumbra width (about 0.5 mm out of 5 mm to 8mm) and reduced (1% to 2%) scatter dose beyond the field edges for both 6 MV and 18 MV beams, compared with the water phantom scanner. For profiles of the MLC-shaped 6 MV photon beam, a similar agreement was observed. For profiles of electron beams scanned at 2.9 cm depth of Lucite (i.e., at 3.3 cm depth of water), larger disagreements in profiles (3% to 4%) and penumbra width (3 mm to 4 mm out of 12 mm

  12. A feasibility study of the Dynamic Phantom scanner for quality assurance of beam profiles at various gantry angles

    Science.gov (United States)

    Zhang, Yunkai; Hsi, Wen C.; Chu, James C.H.; Bernard, Damian B.; Abrams, Ross A.

    2005-01-01

    The effect of gantry rotation on beam profiles of photon and electron beams is an important issue in quality assurance for radiotherapy. To address variations in the profiles of photon and electron beams at different gantry angles, a Dynamic Phantom scanner composed of a 20×12×6 cm3 scanning Lucite block was designed as a cross‐beam‐profile scanner. To our knowledge, differences between scanned profiles acquired at different gantry angles with a small size Lucite block and those acquired a full‐size (60×60×50 cm3) water phantom have not been previously investigated. We therefore performed a feasibility study for a first prototype Dynamic Phantom scanner without a gantry attachment mount. Radiation beams from a Varian LINAC 21EX and 2100C were used. Photon beams (6 MV and 18 MV) were shaped by either collimator jaws or a Varian 120 Multileaf (MLC) collimator, and electron beams (6 MeV, 12 MeV, and 20 MeV) were shaped by a treatment cone. To investigate the effect on profiles by using a Lucite block, a quantitative comparison of scanned profiles with the Dynamic Phantom and a full‐size water phantom was first performed at a 0° gantry angle for both photon and electron beams. For photon beam profiles defined by jaws at 1.0 cm and 5.0 cm depths of Lucite (i.e., at 1.1 cm and 5.7 cm depth of water), a good agreement (less than 1% variation) inside the field edge was observed between profiles scanned with the Dynamic Phantom and with a water phantom. The use of Lucite in the Dynamic Phantom resulted in reduced penumbra width (about 0.5 mm out of 5 mm to 8 mm) and reduced (1% to 2%) scatter dose beyond the field edges for both 6 MV and 18 MV beams, compared with the water phantom scanner. For profiles of the MLC‐shaped 6 MV photon beam, a similar agreement was observed. For profiles of electron beams scanned at 2.9 cm depth of Lucite (i.e., at 3.3 cm depth of water), larger disagreements in profiles (3% to 4%) and penumbra width (3 mm to 4 mm out of 12 mm

  13. Optimizing 4D cone beam computed tomography acquisition by varying the gantry velocity and projection time interval

    International Nuclear Information System (INIS)

    O’Brien, Ricky T; Cooper, Benjamin J; Keall, Paul J

    2013-01-01

    Four dimensional cone beam computed tomography (4DCBCT) is an emerging clinical image guidance strategy for tumour sites affected by respiratory motion. In current generation 4DCBCT techniques, both the gantry rotation speed and imaging frequency are constant and independent of the patient’s breathing which can lead to projection clustering. We present a mixed integer quadratic programming (MIQP) model for respiratory motion guided-4DCBCT (RMG-4DCBCT) which regulates the gantry velocity and projection time interval, in response to the patient’s respiratory signal, so that a full set of evenly spaced projections can be taken in a number of phase, or displacement, bins during the respiratory cycle. In each respiratory bin, an image can be reconstructed from the projections to give a 4D view of the patient’s anatomy so that the motion of the lungs, and tumour, can be observed during the breathing cycle. A solution to the full MIQP model in a practical amount of time, 10 s, is not possible with the leading commercial MIQP solvers, so a heuristic method is presented. Using parameter settings typically used on current generation 4DCBCT systems (4 min image acquisition, 1200 projections, 10 respiratory bins) and a sinusoidal breathing trace with a 4 s period, we show that the root mean square (RMS) of the angular separation between projections with displacement binning is 2.7° using existing constant gantry speed systems and 0.6° using RMG-4DCBCT. For phase based binning the RMS is 2.7° using constant gantry speed systems and 2.5° using RMG-4DCBCT. The optimization algorithm presented is a critical step on the path to developing a system for RMG-4DCBCT. (paper)

  14. Motion control of a gantry crane with a container

    Science.gov (United States)

    Shugailo, T. S.; Yushkov, M. P.

    2018-05-01

    The transportation of a container by a gantry crane in a given time from one point of space to another is considered. The system is at rest at the end of the motion. A maximum admissible speed is taken into account. The control force is found using either the Pontryagin maximum principle or the generalized Gauss principle. The advantages of the second method over the first one is demonstrated.

  15. The development of a mobile CT-scanner gantry for use in the operating room

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Kobayashi, Shigeaki; Koike, Jouji; Harada, Takanobu; Kanemaru, Kei

    1989-01-01

    We report the development of a mobile CT-scanner gantry which uses a gantry platter. This system has been developed for use in the operating room. We designed a small lift to move the gantry unit of the scanner: the gantry carrier. The scanner gantry is fixed to the gantry carrier. A phantom test with a digitalized operating table worked well in the laboratory, and operating-room use showed that there was no deterioration in image quality. The mobile gantry system has been developed to increase the efficiency of the operating CT-scanner system. This system enables us to obtain CT images during surgery of immediately after surgery in the operating room, i.e., in cases that are not transferable to the radiological department. The operability is basically the same as that of a conventional mobile X-ray unit. Theoretically, this unit could be used with any CT scanner and in any operating room. (author)

  16. Fuzzy Controllers for a Gantry Crane System with Experimental Verifications

    Directory of Open Access Journals (Sweden)

    Naif B. Almutairi

    2016-01-01

    Full Text Available The control problem of gantry cranes has attracted the attention of many researchers because of the various applications of these cranes in the industry. In this paper we propose two fuzzy controllers to control the position of the cart of a gantry crane while suppressing the swing angle of the payload. Firstly, we propose a dual PD fuzzy controller where the parameters of each PD controller change as the cart moves toward its desired position, while maintaining a small swing angle of the payload. This controller uses two fuzzy subsystems. Then, we propose a fuzzy controller which is based on heuristics. The rules of this controller are obtained taking into account the knowledge of an experienced crane operator. This controller is unique in that it uses only one fuzzy system to achieve the control objective. The validity of the designed controllers is tested through extensive MATLAB simulations as well as experimental results on a laboratory gantry crane apparatus. The simulation results as well as the experimental results indicate that the proposed fuzzy controllers work well. Moreover, the simulation and the experimental results demonstrate the robustness of the proposed control schemes against output disturbances as well as against uncertainty in some of the parameters of the crane.

  17. Gantry Crane Scheduling with Interference Constraints in Railway Container Terminals

    Directory of Open Access Journals (Sweden)

    Peng Guo

    2013-04-01

    Full Text Available Railway container terminals, where gantry cranes are responsible for loading and unloading containers between freight trains and yards, are important hubs of hinterland logistics transportation. Terminal managers confront the challenge in improving the efficiency of their service. As the most expensive equipment in a terminal, the operational performance of gantry cranes is a crucial factor. In this paper, the gantry crane scheduling problem of railway container terminals is investigated. A mixed integer programming model which considers the effect of dwelling position dependent processing times is formulated. In addition, the safety distances, the travel times and the non-crossing requirement of cranes are incorporated in the mathematical model. A novel discrete artificial bee colony algorithm is presented to solve the intractable scheduling problem. Computational experiments are conducted to evaluate the proposed algorithm on some randomly constructed instances based on typical terminal operational data. Experimental results show that the proposed approach can obtain near optimal solutions for the investigated problem in a reasonable computational time.

  18. Ports Primer: 3.2 Port Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  19. Dynamic analysis of the gantry crane used for transporting BOP

    Directory of Open Access Journals (Sweden)

    Stanisław WOJCIECH

    2008-01-01

    Full Text Available In the paper the dynamic analysis of a gantry crane used for transporting of BOP (BlowOut Preventer is presented. The crane is placed on a drilling platform. Sea waves cause motion of the platform and the load. Description of such systems can be used in the design process of control systems which allows us to compensate waving. Homogenous transformations and joint coordinates are used to describe behavior of the system. Equations of motion are derived using the Lagrange equations of the second order. In the paper the results of numerical calculations are presented as well.

  20. Conceptual and ion-optical designs of an isocentric gantry for light-ion cancer therapy

    International Nuclear Information System (INIS)

    Vorobiev, L.G.; Weick, H.; Wollnik, H.

    1998-02-01

    Conceptual and ion-optical designs of an isocentric gantry are presented. The gantry is designed for light-ion therapy using a 6 Tm carbon beam. Its main characteristics are: 5 m overall radius, 1.4 m drift to the patient, 20x10 cm 2 treatment field, and two-direction active parallel scanning of a fine focused pencil beam. To achieve these features, the beam scanners are optimally positioned upstream the last 90 bending section consisting of two 45 sector magnets with 4 oblique field boundaries and different apertures. The gantry concept is a compromise between 'barrel' and 'conical' gantry shapes and is likely the most space-saving configuration of single-plane isocentric gantries. This new so-called 'short barrel' configuration features also small aperture quadruple lenses, low intermediate dispersion and a fully achromatic beam transport system. Its overall dimensions stay close to the size of the existing proton gantries. (orig.)

  1. A novel beam optics concept in a particle therapy gantry utilizing the advantages of superconducting magnets.

    Science.gov (United States)

    Gerbershagen, Alexander; Meer, David; Schippers, Jacobus Maarten; Seidel, Mike

    2016-09-01

    A first order design of the beam optics of a superconducting proton therapy gantry beam is presented. The possibilities of superconducting magnets with respect to the beam optics such as strong fields, large apertures and superposition of different multipole fields have been exploited for novel concepts in a gantry. Since various techniques used in existing gantries have been used in our first design steps, some examples of the existing superconducting gantry designs are described and the necessary requirements of such a gantry are explained. The study of a gantry beam optics design is based on superconducting combined function magnets. The simulations have been performed in first order with the conventional beam transport codes. The superposition of strong dipole and quadrupole fields generated by superconducting magnets enables the introduction of locally achromatic bending sections without increasing the gantry size. A rigorous implementation of such beam optics concepts into the proposed gantry design dramatically increases the momentum acceptance compared to gantries with normal conducting magnets. In our design this large acceptance has been exploited by the implementation of a degrader within the gantry and a potential possibility to use the same magnetic field for all energies used in a treatment, so that the superconducting magnets do not have to vary their fields during a treatment. This also enables very fast beam energy changes, which is beneficial for spreading the Bragg peak over the thickness of the tumor. The results show an improvement of its momentum acceptance. Large momentum acceptance in the gantry creates a possibility to implement faster dose application techniques. Copyright © 2016. Published by Elsevier GmbH.

  2. Beam-optics study of the gantry beam delivery system for light-ion cancer therapy

    International Nuclear Information System (INIS)

    Pavlovic, M.

    1995-12-01

    Ion optics considerations on the granty-like beam delivery system for light-ion cancer therapy are presented. A low-angle active beam scanning in two directions is included in the preliminary gantry design. The optical properties of several gantry modifications are discussed. (orig.)

  3. An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments

    International Nuclear Information System (INIS)

    Rowshanfarzad, Pejman; McGarry, Conor K; Barnes, Michael P; Sabet, Mahsheed; Ebert, Martin A

    2014-01-01

    In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance. The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated. The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs. The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics

  4. Modular design of a scanning Gantry for animal SPECT, PET and CT applications

    International Nuclear Information System (INIS)

    Brady, J.A.M.; Lerch, M.; Bourke, J.; Rozenfeld, A.B.; Meikle, S.R.

    2005-01-01

    Full text: Using the modular design methodology, we have developed a scanning gantry system; custom designed for multi-modality nuclear imaging techniques (NITs) and the CoALA SPECT project. This paper discusses the gantry's flexible modular design and how significant components and functionality have been reused in other medical physics related instrumentation developed at the Centre for Medical Radiation Physics, University of Wollongong. The gantry is designed to meet the exacting requirements of researchers in new radiotracer development who require accurate functional and anatomical information-the scanning gantry has a linear stepping accuracy of +/-12.5 microns and an angular accuracy of +/-0.03 degree. The scanning gantry is a precision instrument that is also affordable to research groups working in small laboratories or universities. Copyright (2005) Australian Institute of Physics

  5. Three ports versus four ports laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shah, S.F.; Waqar, S.; Chaudry, M.A.; Hameed, S.

    2017-01-01

    To compare three ports laparoscopic cholecystectomy and four ports laparoscopic cholecystectomy in terms of complications, time taken to complete the procedure, hospital stay and cost effectiveness in local perspective. Methodology: This randomized control trial included 60 patients who underwent elective laparoscopic cholecystectomy at Department of Surgery, Pakistan Institute of Medical Sciences, Islamabad, Pakistan from January 2013 to June 2013. These patients were randomized on computer generated table of random numbers into group A and Group B. In Group A patients four ports were passed to perform laparoscopic cholecystectomy and in Group B patients three ports were passed to perform the procedure. Results: The mean age in both groups was 44 years (range 18-72). Three ports laparoscopic cholecystectomy (43 min) took less time to complete than four ports laparoscopic cholecystectomy (51 min). Patients in three ports laparoscopic cholecystectomy experienced less pain as compared to four ports group. The total additional analgesia requirement in 24 hours calculated in milligrams was less in three port laparoscopic cholecystectomy group as compared four port laparoscopic cholecystectomy group. The mean hospital stay in three port laparoscopic cholecystectomy group is 25 hours while the mean hospital stay in the four port laparoscopic cholecystectomy group is 28 hours. Conclusion: Three ports laparoscopic cholecystectomy is safe and effective procedure and it did not compromise the patient safety. (author)

  6. Principal Ports and Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  7. Principal Ports and Facilities

    Data.gov (United States)

    California Department of Resources — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  8. 78 FR 68477 - Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of...

    Science.gov (United States)

    2013-11-14

    ...] Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of... requirements specified in the Standard on Overhead and Gantry Cranes (29 CFR 1910.179). DATES: Comments must be... information (29 U.S.C. 657). The paperwork provisions of the Standard on Overhead and Gantry Cranes specify...

  9. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams.

    Science.gov (United States)

    Masood, U; Cowan, T E; Enghardt, W; Hofmann, K M; Karsch, L; Kroll, F; Schramm, U; Wilkens, J J; Pawelke, J

    2017-07-07

    parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.

  10. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams

    Science.gov (United States)

    Masood, U.; Cowan, T. E.; Enghardt, W.; Hofmann, K. M.; Karsch, L.; Kroll, F.; Schramm, U.; Wilkens, J. J.; Pawelke, J.

    2017-07-01

    parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.

  11. Port of Rotterdam

    NARCIS (Netherlands)

    Veenstra, A.W.

    2014-01-01

    The port of Rotterdam is one of the largest ports in the World and has great significance for the Dutch and European economy. Newly appointed TU/e professor Albert Veenstra explains if and how the Port of Rotterdam is affected by the economic crisis. With other European ports closing in, what can

  12. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Hvolby, Hans-Henrik

    2014-01-01

    While large global ports are recognised as playing a central role in many supply chains as logistic gateways, smaller regional ports have been more stagnant and have not reached the same level of development as the larger ports. The research literature in relation to port development is also...

  13. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  14. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  15. Management of Port Operations

    OpenAIRE

    Gheorghe BASANU; Georgiana NUKINA

    2011-01-01

    The Management of port operation requires the proper and efficient use of port facility, equipment for cargo handling, berth facilities, waterways and roads. It also entails the use of effective communications system, storage facilities, and dockworkers. The whole activities mentioned above form the bulk of port operations. The aspiration of port operator is to get cargo through the gateway of ports as fast as possible on to other modes of transport (rail or road) with a minimal cost to them ...

  16. Real-Time Dispatching of Rubber Tired Gantry Cranes in Container Terminals

    National Research Council Canada - National Science Library

    McNary, Bradley S

    2008-01-01

    ... significant growth in container traffic. Efficiently managing of rubber tired gantry cranes and planning container placement within the terminal are two ways to increase the overall efficiency of a terminal...

  17. Influence of gantry angle in helical computed tomography. Usefullness of 1-dimension sharpness filter

    Energy Technology Data Exchange (ETDEWEB)

    Kawano, Hirofumi; Suzuki, Toru; Matsuura, Shigeru; Kai, Tsuyoshi; Shimizu, Toshiyuki [Hyuga Hospital of Saiseikai Foundation, Kadogawa, Miyazaki (Japan)

    2001-05-01

    When we let gantry tilt and do scan in helical CT, vertical sharpness deteriorates. We were able to revise it with 1-dimensional sharpness filter which the square sum of difference of MTF was compared, and was designed this time. And the unsharpness was in proportion to sin of gantry angle. As a result, we led several sets of frequency emphasis degree. There is a model to built 1-dimension sharpness filter in a scan plan. It is useful for clinical diagnoses. (author)

  18. Influence of gantry angle in helical computed tomography. Usefullness of 1-dimension sharpness filter

    International Nuclear Information System (INIS)

    Kawano, Hirofumi; Suzuki, Toru; Matsuura, Shigeru; Kai, Tsuyoshi; Shimizu, Toshiyuki

    2001-01-01

    When we let gantry tilt and do scan in helical CT, vertical sharpness deteriorates. We were able to revise it with 1-dimensional sharpness filter which the square sum of difference of MTF was compared, and was designed this time. And the unsharpness was in proportion to sin of gantry angle. As a result, we led several sets of frequency emphasis degree. There is a model to built 1-dimension sharpness filter in a scan plan. It is useful for clinical diagnoses. (author)

  19. Dosimetry with the scanned proton beam on the PSI gantry

    International Nuclear Information System (INIS)

    Coray, A.; Pedroni, E.; Boehringer, T.; Lin, S.; Lomax, T.; Goitein, G.

    2002-01-01

    Full text: The irradiation facility at PSI is designed for the treatment of deep seated tumours with a proton beam energy of up to 270 MeV. The spot scanning technique, which uses a proton pencil beam applied to the patient, is performed on a compact isocentric gantry. An optimal three-dimensional conformation of the dose distribution to the target volume can be realized. A fast steering system and a redundant interlock system are in operation. The dose delivery is controlled by a parallel plate transmission chamber, which is calibrated in terms of number of protons per monitor unit. The therapy planning is based on an empirical model, which takes into account attenuation of primary protons and losses outside the primary beam through secondary products. The therapy plan predicts an absolute dose. The calibration of the primary monitor is done using a reference thimble ionization chamber inside a homogeneous geometrical dose volume. The reference system is calibrated in a cobalt field at the national office of metrology in terms of absorbed dose to water. The dosimetry protocol used up to last year was based on the ICRU Report Nr. 59, we have switched to the IAEA Code of Practice starting this beam period. Data on the monitor calibration for various energies and using two different reference systems will be shown. The calibration of the beam monitor using a Faraday Cup in the static pencil beam results in a good agreement with the ionization chamber measurements, with a deviation of less than 1%. Following the daily setup of the machine, an extensive quality control and safety check of the whole system is performed. The daily dosimetry quality assurance program includes: measurement of dose rate and monitor ratios; check of the beam position monitors; measurement of a depth dose curve; dose measurement in a regular dose field. The doses measured daily in a regular scanned field show a standard deviation of about 1 %. Further daily checks results, which illustrate

  20. The effect of restraints type on the generated stresses in gantry crane beam

    Directory of Open Access Journals (Sweden)

    Sowa Leszek

    2018-01-01

    Full Text Available This paper includes an analysis of the mechanical phenomena in the gantry crane beam, because the cranes are currently one of the most common devices for the transporting loads. Designing modern mechanical structures is a complex task that requires the use of appropriate tools. Such a modern tool is the numerical simulation, which uses different numerical methods. One of the best known methods is the finite element method, also used here. Simulations are limited to analysis of the strength of the gantry crane beam that was the loaded of the force load movement along its length. The numerical analysis was made to the gantry crane beam which cross-section was an I-beam and ends were fixed in different ways. As the result of numerical calculations, the stresses and displacements of the structure of gantry were obtained. The influence of the restraints type and changing the loading force position on generate the Huber-Misses stress in the gantry crane beam was estimated. The aim was to ensure that the maximum equivalent stress generated in the gantry crane beam was less than the strength of material, because then the construction is safe.

  1. A novel gantry for proton therapy at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pedroni, E.; Boehringer, T.; Coray, A.; Goitein, G.; Grossmann, M.; Lomax, A.; Lin, S.; Jermann, M.

    2001-01-01

    PSI has gained in the last few years the unique experience of using a proton therapy system based on a beam scanning delivery technique and on a compact gantry. This knowledge is now bringing forth new initiatives. We are continuously producing significant modifications and improvements to the present system, gantry 1. The major new step is however the decision of PSI to purchase a dedicated accelerator for the medical project. In the context of the expansion of the medical project of PSI (project PROSCAN) we have also started to plan the realisation of a second proton gantry, gantry 2. In this lecture we present the main ideas for the novel gantry, which will be based on one hand on the experience with the present technology, but on the other hand should be designed as a system more open to further developments and needs. The established and the future requirements for the beam delivery on the new gantry were routed into the specification list for the dedicated accelerator

  2. Port Authority Best Practices

    Science.gov (United States)

    Best practices for port authorities include near-port community collaboration, anti-idling policies, expanding off-peak hours, development of EMS, developing an emissions inventory, education, electric power and substituting trucking for rail or barge.

  3. US Ports of Entry

    Data.gov (United States)

    Department of Homeland Security — HSIP Non-Crossing Ports-of-Entry A Port of Entry is any designated place at which a CBP officer is authorized to accept entries of merchandise to collect duties, and...

  4. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  5. Getting Port Governance Right

    DEFF Research Database (Denmark)

    de Langen, Peter; Saragiotis, Periklis

    2018-01-01

    This chapter discusses the relevance of ports for economic development and next identifies port governance as a critical determinant of a well-functioning port industry. While in the past decades privately owned terminal operating companies have emerged and contributed to more efficient supply ch...

  6. Shipping emissions in ports

    OpenAIRE

    Merk, Olaf

    2014-01-01

    Shipping emissions in ports are substantial, accounting for 18 million tonnes of CO2 emissions, 0.4 million tonnes of NOx, 0.2 million of SOx and 0.03 million tonnes of PM10 in 2011. Around 85% of emissions come from containerships and tankers. Containerships have short port stays, but high emissions during these stays. Most of CO2 emissions in ports from shipping are in Asia and Europe (58%), but this share is low compared to their share of port calls (70%). European ports have much less emi...

  7. Sea freight - Antwerp Port

    Directory of Open Access Journals (Sweden)

    NEACSU Nicoleta Andreea

    2017-01-01

    Full Text Available Shipping plays a vital role in achieving the movement of goods, both in terms of quantity and efficiency. This paper presents the role and advantages of shipping in the global economy and analyzes the development and Antwerp Port activity. Currently, the second most important trading port in Europe and 14th in the ranking of most important ports that handle containers worldwide, the Port of Antwerp, Belgium is a port in the heart of Europe, accessible to large sized vessels. 200 years of constructing infrastructure and logistics around the central location, as well as pressure from Rotterdam, that had an impact on the competitiveness of the port of Antwerp, all this led the port to occupy a leading position in the top rankings.

  8. Control Strategy for Automatic Gantry Crane Systems: A Practical and Intelligent Approach

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2007-12-01

    Full Text Available The use of gantry crane systems for transporting payload is very common in building constructions. However, moving the payload using the crane is not an easy task especially when strict specifications on the swing angle and on the transfer time need to be satisfied. Various attempts in controlling gantry cranes system based on open- loop and closed-loop control systems were proposed. However, most of the proposed controllers were designed based on the model and parameter of the crane system. In general, modeling and parameter identifications are troublesome and time consuming task. To overcome this problem, in this paper, a practical and intelligent control method for automatic gantry crane is introduced and evaluated experimentally. The results show that the proposed method is not only effective for controlling the crane but also robust to parameter variation.

  9. Control Strategy for Automatic Gantry Crane Systems: A Practical and Intelligent Approach

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2008-11-01

    Full Text Available The use of gantry crane systems for transporting payload is very common in building constructions. However, moving the payload using the crane is not an easy task especially when strict specifications on the swing angle and on the transfer time need to be satisfied. Various attempts in controlling gantry cranes system based on open- loop and closed-loop control systems were proposed. However, most of the proposed controllers were designed based on the model and parameter of the crane system. In general, modeling and parameter identifications are troublesome and time consuming task. To overcome this problem, in this paper, a practical and intelligent control method for automatic gantry crane is introduced and evaluated experimentally. The results show that the proposed method is not only effective for controlling the crane but also robust to parameter variation.

  10. X-band Linac for a 6 MeV dual-head radiation therapy gantry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hyun; Shin, Seung-Wook; Lee, Jongchul; Kim, Hui-Su [WCU Department of Energy Science, Suwon 440-746 (Korea, Republic of); Lee, Byeong-No; Lee, Byung-Chul [Radiation Instrumentation Research Division, Korea Atomic Energy Research Institute, Jeongeup 56212 (Korea, Republic of); Park, Hyung-dal; Song, Ki-back [Radiation Technology eXcellence (RTX), Daejeon 305-500 (Korea, Republic of); Song, Ho-seung; Mun, Sangchul; Ha, Donghyup [School of Information and Communication Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Chai, Jong-Seo, E-mail: jschai@skku.edu [School of Information and Communication Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2017-04-21

    We developed a design for a 6 MeV X-band linear accelerator for radiation therapy in a dual-head gantry layout. The dual-head gantry has two linacs that can be operated independently. Each X-band linac accelerates electron bunches using high-power RF and generates X-rays for radiation therapy. It requires a versatile RF system and pulse sequence to accomplish various radiation therapy procedures. The RF system consists of 9.3 GHz, 2 MW X-band magnetron and associated RF transmission components. A test linac was assembled and operated to characterize its RF performance without beam. This paper presents these results along with a description of the gantry linacs and their operational requirements.

  11. An improved method to accurately calibrate the gantry angle indicators of the radiotherapy linear accelerators

    International Nuclear Information System (INIS)

    Chang Liyun; Ho, S.-Y.; Du, Y.-C.; Lin, C.-M.; Chen Tainsong

    2007-01-01

    The calibration of the gantry angle indicator is an important and basic quality assurance (QA) item for the radiotherapy linear accelerator. In this study, we propose a new and practical method, which uses only the digital level, V-film, and general solid phantoms. By taking the star shot only, we can accurately calculate the true gantry angle according to the geometry of the film setup. The results on our machine showed that the gantry angle was shifted by -0.11 deg. compared with the digital indicator, and the standard deviation was within 0.05 deg. This method can also be used for the simulator. In conclusion, this proposed method could be adopted as an annual QA item for mechanical QA of the accelerator

  12. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  13. 75 FR 44288 - Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of...

    Science.gov (United States)

    2010-07-28

    ...] Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of... requirements specified in the Standard on Overhead and Gantry Cranes (29 CFR 1910.179). DATES: Comments must be... requirements for: Marking the rated load of cranes; preparing certification records to verify the inspection of...

  14. SU-F-T-207: Does the Greater Flexibility of Pencil Beam Scanning Reduce the Need for a Proton Gantry?

    Energy Technology Data Exchange (ETDEWEB)

    Yan, S; Depauw, N; Flanz, J; Adams, J; Gorissen, BL; Shih, H; Bortfeld, T; Lu, H [Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA (United States)

    2016-06-15

    Purpose: Gantry-less proton treatment facility could lower the capital cost of proton therapy. This study investigates the dosimetric feasibility of using only coplanar pencil beam scanning (PBS) beams for those patients who had beam angles that would not have been deliverable without the gantry. Those coplanar beams are implemented on gantry-less horizontal beam-line with patients in sitting or standing positions. Methods: We have selected ten patients (seven head-and-neck, one thoracic, one abdominal and one pelvic case) with clinically delivered double scattering (DS) or PBS treatment plans with beam angles that were challenging to achieve without a gantry. After removing these beams angles, PBS plans were optimized for gantry-less intensity modulated proton therapy (IMPT) or single field optimization (SFO) with multi-criteria optimization (MCO). For head-and-neck patients who were treated by DS, we generated PBS plans with non-coplanar beams for comparison. Dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, D-2 and D-98 were reported. Robustness analysis was performed with ±2.5 mm setup errors and ±3.5% range uncertainties for three head-and-neck patients. Results: PBS-gantry-less plans provided more homogenous target coverage and significant improvements on organs-at-risk (OARs) sparing, compared to passive scattering treatments with a gantry. The PBS gantry-less treatments reduced the HI for target coverage by 1.3% to 47.2%, except for a suprasellar patient and a liver patient. The PBS-gantry-less plans reduced the D-mean of OARs by 3.6% to 67.4%. The PBS-gantry plans had similar target coverage and only marginal improvements on OAR sparing as compared to the PBS-gantry-less plans. These two PBS plans also had similar robustness relative to range uncertainties and setup errors. Conclusion: The gantry-less plans have with less mean dose to OARs and more homogeneous target coverage. Although the PBS-gantry plans have slightly improved

  15. Port Stakeholder Summit: Advancing More Sustainable Ports (April 2014)

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  16. Stabilizing model predictive control of a gantry crane based on flexible set-membership constraints

    NARCIS (Netherlands)

    Iles, Sandor; Lazar, M.; Kolonic, Fetah; Jadranko, Matusko

    2015-01-01

    This paper presents a stabilizing distributed model predictive control of a gantry crane taking into account the variation of cable length. The proposed algorithm is based on the off-line computation of a sequence of 1-step controllable sets and a condition that enables flexible convergence towards

  17. Alternating-gradient canted cosine theta superconducting magnets for future compact proton gantries

    Directory of Open Access Journals (Sweden)

    Weishi Wan

    2015-10-01

    Full Text Available We present a design of superconducting magnets, optimized for application in a gantry for proton therapy. We have introduced a new magnet design concept, called an alternating-gradient canted cosine theta (AG-CCT concept, which is compatible with an achromatic layout. This layout allows a large momentum acceptance. The 15 cm radius of the bore aperture enables the application of pencil beam scanning in front of the SC-magnet. The optical and dynamic performance of a gantry based on these magnets has been analyzed using the fields derived (via Biot-Savart law from the actual windings of the AG-CCT combined with the full equations of motion. The results show that with appropriate higher order correction, a large 3D volume can be rapidly scanned with little beam shape distortion. A very big advantage is that all this can be done while keeping the AG-CCT fields fixed. This reduces the need for fast field ramping of the superconducting magnets between the successive beam energies used for the scanning in depth and it is important for medical application since this reduces the technical risk (e.g., a quench associated with fast field changes in superconducting magnets. For proton gantries the corresponding superconducting magnet system holds promise of dramatic reduction in weight. For heavier ion gantries there may furthermore be a significant reduction in size.

  18. An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering

    Directory of Open Access Journals (Sweden)

    Ming Yan

    2006-01-01

    Full Text Available FDK algorithm is a well-known 3D (three-dimensional approximate algorithm for CT (computed tomography image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.

  19. Port Harcourt Medical Journal

    African Journals Online (AJOL)

    Port Harcourt Medical Journal's objectives are to disseminate medical information from the College of Health Sciences, University of Port Harcourt and the rest of the national and international medical community; act as a medium for the articulation of research and findings from same as well as proceedings of medical ...

  20. The Flexible Port

    NARCIS (Netherlands)

    Taneja, P.

    2013-01-01

    Ports are beset with many uncertainties about their futures. They are confronted with new demands in terms of functions and scales, new external constraints, and changed expectations. The inability to adequately meet these demands can mean costly adaptations for a port, or loss of cargo and

  1. Port Stakeholder Summit - April 2014

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  2. Anti-Swing Control of Gantry and Tower Cranes Using Fuzzy and Time-Delayed Feedback with Friction Compensation

    Directory of Open Access Journals (Sweden)

    H.M. Omar

    2005-01-01

    Full Text Available We designed a feedback controller to automate crane operations by controlling the load position and its swing. First, a PD tracking controller is designed to follow a prescribed trajectory. Then, another controller is added to the control loop to damp the load swing. The anti-swing controller is designed based on two techniques: a time-delayed feedback of the load swing angle and an anti-swing fuzzy logic controller (FLC. The rules of the FLC are generated by mapping the performance of the time-delayed feedback controller. The same mapping method used for generating the rules can be applied to mimic the performance of an expert operator. The control algorithms were designed for gantry cranes and then extended to tower cranes by considering the coupling between the translational and rotational motions. Experimental results show that the controller is effective in reducing load oscillations and transferring the load in a reasonable time. To experimentally validate the theory, we had to compensate for friction. To this end, we estimated the friction and then applied a control action to cancel it. The friction force was estimated by assuming a mathematical model and then estimating the model coefficients using an off-line identification technique, the method of least squares (LS.

  3. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  4. COSIMA-ES-PORT

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Leleur, Steen

    2007-01-01

    This article describes the results of the research project – WP3 East-west, Interreg IIIB – concerning the de¬velop¬ment of a new composite decision model, COSIMA-ES-PORT, for the assessment of three pre-feasibility studies situated at the Port of Esbjerg: a road project, a railway project...... and a multimodal terminal. The three studies indicates that a new road connection to the Port of Esbjerg is a very profitable project due to large travel time savings, whereas a new railway connection is not economically viable. However, a new multimodal terminal is also a very profitable project. The COSIMA...

  5. Revisiting port pricing : a proposal for seven port pricing principles

    NARCIS (Netherlands)

    Van Den Berg, R.; De Langen, P.W.; Van Zuijlen, P.C.J.

    2017-01-01

    A review of seven large landlord port authorities around the world reveals a notable diversity of pricing structures. While port authorities increasingly act as commercial undertakings, port pricing often seems to be not driven by commercial considerations. In this paper, we argue that ports can be

  6. Oluvil Port Development Project

    DEFF Research Database (Denmark)

    Frigaard, Peter; Margheritini, Lucia

    Oluvil Port Development Project is the first development of a large port infrastructure in the entire eastern coastline of Sri Lanka. The project is supported by the Danish Foreign Ministry. Feasibility studies and detailed design studies were carried out by Lanka Hydraulic Institute Ltd during...... the years 1995 to 2003. The design was reviewed by COWI a/s. Construction of the port was started in 2008. MT Højgaard a/s acted as contractor. The outer breakwaters were constructed as first part of the project. During and after completion of the breakwaters a serious beach erosion and sand accumulation...... has been observed. Severe erosion is seen north of the harbour and some accumulation of sand is seen south of the harbour. On a sandy coastline like the one in Oluvil such erosion problems as observed are very typical. The report: Oluvil Port Development Project: Studies on Beach Erosion written...

  7. Modelling and Metaheuristic for Gantry Crane Scheduling and Storage Space Allocation Problem in Railway Container Terminals

    Directory of Open Access Journals (Sweden)

    Ming Zeng

    2017-01-01

    Full Text Available The gantry crane scheduling and storage space allocation problem in the main containers yard of railway container terminal is studied. A mixed integer programming model which comprehensively considers the handling procedures, noncrossing constraints, the safety margin and traveling time of gantry cranes, and the storage modes in the main area is formulated. A metaheuristic named backtracking search algorithm (BSA is then improved to solve this intractable problem. A series of computational experiments are carried out to evaluate the performance of the proposed algorithm under some randomly generated cases based on the practical operation conditions. The results show that the proposed algorithm can gain the near-optimal solutions within a reasonable computation time.

  8. High precision tracking control of a servo gantry with dynamic friction compensation.

    Science.gov (United States)

    Zhang, Yangming; Yan, Peng; Zhang, Zhen

    2016-05-01

    This paper is concerned with the tracking control problem of a voice coil motor (VCM) actuated servo gantry system. By utilizing an adaptive control technique combined with a sliding mode approach, an adaptive sliding mode control (ASMC) law with friction compensation scheme is proposed in presence of both frictions and external disturbances. Based on the LuGre dynamic friction model, a dual-observer structure is used to estimate the unmeasurable friction state, and an adaptive control law is synthesized to effectively handle the unknown friction model parameters as well as the bound of the disturbances. Moreover, the proposed control law is also implemented on a VCM servo gantry system for motion tracking. Simulations and experimental results demonstrate good tracking performance, which outperform traditional control approaches. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Slewing Port Jib Cranes

    OpenAIRE

    Boris Visočnik; Stojan Kravanja

    2002-01-01

    The paper presents slewing port cranes with a luffing jib. The advantages of slewing port jib cranes are high lifting capacities, high speeds of re-loading and excellent mobility since they are capable of load lifting, travelling, luffing and slewing. The paper gives a detailed description of their characteristics such as the highest reached load-carrying capacities, speeds of motion and accelerations. It also presents the crane assembly, driving mechanisms, loads and load cases, transport by...

  10. Craniospinal treatment with IMRT multi-isocentric and image-guided linear accelerator based on Gantry

    International Nuclear Information System (INIS)

    Sanz Beltran, M.; Caballero Perea, B.; Rodriguez Rodriguez, C.; Arminio Diaz, E.; Lopez Fernandez, A.; Gomez Fervienza, J. R.; Crespo Diez, P.; Cantarero Valenzuela, N.; Alvarez Sanchez, M.; Martin Martin, G.; Gomez Fervienza, J. r.; Crespo Diez, P.; Cantarero Valenzuela, N.; Alvarez Sanchez, M.; Martin Martin, G.

    2011-01-01

    The objective is the realization of craniospinal treatment with a linear accelerator equipped with gantry based on MLC, carbon fiber table and Image Guided capability. The great length of treatment (patient l,80m in height) was a great difficulty for want of full length of the longitudinal movement of the table to adequately cover the PTV, plus free metallic screws fastening the head of the table extender preventing further incidents.

  11. Development of a MPPC-based prototype gantry for future MRI-PET scanners

    Science.gov (United States)

    Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Ohshima, T.; Taya, T.; Yamamoto, S.

    2014-12-01

    We have developed a high spatial resolution, compact Positron Emission Tomography (PET) module designed for small animals and intended for use in magnetic resonance imaging (MRI) systems. This module consists of large-area, 4 × 4 ch MPPC arrays (S11830-3344MF; Hamamatsu Photonics K.K.) optically coupled with Ce-doped (Lu,Y)2(SiO4)O (Ce:LYSO) scintillators fabricated into 16 × 16 matrices of 0.5 × 0.5 mm2 pixels. We set the temperature sensor (LM73CIMK-0; National Semiconductor Corp.) at the rear of the MPPC acceptance surface, and apply optimum voltage to maintain the gain. The eight MPPC-based PET modules and coincidence circuits were assembled into a gantry arranged in a ring 90 mm in diameter to form the MPPC-based PET system. We have developed two types PET gantry: one made of non-magnetic metal and the other made of acrylonitrile butadiene styrene (ABS) resins. The PET gantry was positioned around the RF coil of the 4.7 T MRI system. We took an image of a point }22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure the interference between the MPPC-based PET and MRI. The spatial resolution of PET imaging in a transaxial plane of about 1 mm (FWHM) was achieved in all cases. Operating with PET made of ABS has no effect on MR images, while operating with PET made of non-magnetic metal has a significant detrimental effect on MR images. This paper describes our quantitative evaluations of PET images and MR images, and presents a more advanced version of the gantry for future MRI/DOI-PET systems.

  12. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  13. The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT

    International Nuclear Information System (INIS)

    Lee, Sul Mi; An, Chang Hyeon; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; Choi, Hang Moon

    2002-01-01

    The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program.A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0 degree, 15 degrees, and 30 degrees. With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta percha in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  14. Slewing Port Jib Cranes

    Directory of Open Access Journals (Sweden)

    Boris Visočnik

    2002-09-01

    Full Text Available The paper presents slewing port cra11es with a luffing jib.The advantages of slewing port jib cranes are high lifting capacities,high speeds of re-loading and excellent mobility since theyare capable of load lifting, travelling, luffing and slewing. Thepaper gives a detailed description of their characteristics suchas the highest reached load-canying capacities, speeds of motionand accelerations. It also presents the crane assembly,driving mechanisms, loads and load cases, transport by shipsand testing of lifting capacity. As a practical example the paperpresents the slewing port jib crane with the capacity of25!15!5 tat a 27/37/40 m radius made by the Slovenian companyMetalna Maribor for the shipyard 3. Maj, Rijeka, Croatia.

  15. HomePort

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Ravn, Anders Peter

    2013-01-01

    Ambient Intelligence systems use many sensors and actuators, with a diversity of networks, protocols and technologies which makes it impossible to access the devices in a common manner. This paper presents the HomePort software, which provides an open source RESTful interface to heterogeneous...... sensor networks, allowing a simple unified access to virtually any kind of protocol using well known standards. HomePort includes means to provide event notification, as well as a tracing mechanism. The software is implemented and we report on initial experiments and provide an evaluation that shows...

  16. ITER lower port systems integration

    Energy Technology Data Exchange (ETDEWEB)

    Levesy, B., E-mail: bruno.levesy@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baker, D.; Boussier, B.; Bryan, S.; Cordier, J.J.; Dremel, M.; Dell' Orco, G.; Daly, E.; Doshi, B.; Jeannoutot, T.; Friconneau, J.P.; Gliss, C.; Le Barbier, R.; Lachevre, F.; Loughlin, M.; Martin, A.; Martins, J.P.; Maruyama, S.; Palmer, J.; Reichle, R. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The lower port systems are installed inside the vacuum vessel lower ports and in the adjacent port cells. The vacuum vessel ports and penetrations are allocated as follow: -4 ports dedicated to remote handling of the divertor cassettes, contain diagnostics racks and divertor cooling pipes. -5 ports connecting the main vessel to the torus cryopumps, contain divertor cooling pipes, pellet and gas injection pipes and vertical stabilization coil feeders. -3 penetrations connecting torus cryopumps are connected to the vacuum vessel by branch pipes. -Specific penetrations for divertor cooling lines, in-vessel viewing and glow discharge systems. The general layout of the port systems has been revised recently to improve the cryopump (8 t weight, 1.8 m diameter and 2.5 m long) maintenance scheme with remote handling tools and integrate the in-vessel vertical stabilization coil feeders. The port allocation, the pumping ports design, and interfaces in-between ports and cryostat and in-between cryopumps and cryostat have been up-dated. The integration inside the 18 port cells (11 m x 4 m each) has been reviewed to avoid clashes in between systems and to fix the openings in the port cell concrete walls. The new layout integrates safety and neutron-shielding requirements as well as remote handling and maintenance compatibility for the different systems. The paper presents the up-dated integration of the lower port systems inside the ports and the port cells. Interfaces of the port systems with the vacuum vessel, the cryostat and the port cells are described.

  17. Effectiveness of MRI in rotator cuff injury

    International Nuclear Information System (INIS)

    Ohazama, Yuka

    1992-01-01

    To investigate the potential role of MR imaging in rotator cuf disorders, normal volunteers and patients with suspected rotator cuff injury were evaluated with a low field permanent magnet unit which had a wide gantry. MR findings of the patients were also compared with arthrography, subcromial bursography and operative findings. To establish optimal imaging technique and normal MR anatomy, 100 normal volunteers were examined. On proton density images, signal intensity of the rotator cuff tendon was low and homogenous, and that of rotator cuff muscles was intermediate. On T2 weighted images, signal intensity of muscles and tendon was decreased and that of joint effusion became brighter. In 38 patients with suspected rotator cuff injury, the signal intensity of the rotator cuff was increased to various degrees. In 21 of them, surgical correction was performed and 17 patients were followed with conservative treatment. MR imaging showed abnormalities in all 38 patients. Arthrography and bursography showed abnormalities in 28 out of 38 patients and 3 of 13 patients respectively. In 21 patients who underwent surgery, tear of the rotator cuff was confirmed, and discrepancies in MR and operative findings existed in 8 patients. In 2 patients, no tear was found in the other examinations, and it was suspected to be horizontal tear or degeneration in the substance of the muscle. MR imaging contributes to diagnosis and treatment planning in patients with suspected rotator cuff injury. (author)

  18. Port Harcourt Medical Journal - Vol 5, No 2 (2010)

    African Journals Online (AJOL)

    Earlier childhood memories and childhood amnesia amnesia among medical students on surgery rotation at the University of Port Harcourt · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. PE Okoro, NP Wichendu, PI Opara, AC Okoro. http://dx.doi.org/10.4314/phmedj.v5i2.

  19. Port entry arrangements

    International Nuclear Information System (INIS)

    Chicken, J.C.; King, M.A.

    1978-01-01

    The objective of the paper is to describe the safety scheme port authorities should establish to deal with any contingency that may result from the visit of a nuclear powered ship. The safety scheme should be devised to cover both normal operation and any accident conditions that could arise while the ship is in port. The paper is divided into three parts. The three parts being: background information, general instructions, and emergency procedures. The background information will describe the nature of the hazards a port authority has to be prepared to deal with, and the philosophical basis for a berthing policy. In the part dealing with general instructions the objective of the safety scheme will be described. Also this part will describe the composition of the Port Safety Panel, allocation of responsibilities, passage and berthing arrangements, general safety precautions, records required, and rescue arrangements. In the part dealing with emergency procedures the role of: the Ship's Master, Harbour Authorities, Local Police, and local Health Services are discussed. As an Appendix to the paper a copy of the safety scheme that has been devised for visits of nuclear merchant ships to Southampton is given

  20. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Steger-Jensen, Kenn

    2012-01-01

    This paper proposes a framework for strategic development of a port’s collaboration with its hinterland. The framework is based on literature relevant to port development and undertakes market perspective by considering import/export data relevant for the region of interest. The series of steps...

  1. Ports and innovation

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Van Schuylenburg, M.

    2012-01-01

    A volatile environment, dynamic markets, and challenges created by new environmental and social consideration demand innovative solutions. Innovation is the implementation of ideas to create value. It promises ports resilience into the future. In this paper we trace some recent successful

  2. Essays on Dry Ports

    NARCIS (Netherlands)

    G.G. Chandrakant (Gujar)

    2011-01-01

    textabstractDue to several reasons, currently the global supply chains are getting stretched further away into the hinterlands from the gateway seaports. This single fact enhances the importance of dry ports. It would not be against logic, to state that in coming times, as a result of ever-growing

  3. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  4. Overview of CMS robotic silicon module assembly hardware based on Aerotech Gantry Positioning system.

    CERN Multimedia

    Honma, Alan

    1999-01-01

    The goal of the robotic silicon module assembly pilot project is to fully automate the gluing and pick and placement of silicon sensors and front-end hybrid onto a carbon-fibre frame. The basis for thesystem is the Aerotech Gantry Positioning System (AGS10000) machineshown in the centre of the picture. To the left is the PC which contains the controller card and runs the user interface. To the rightis the rack of associated electronics which interfaces with the CERNbuilt tooling and vacuum chuck system.

  5. Green Port / Eco Port Project - Applications and Procedures in Turkey

    Science.gov (United States)

    Akgul, Burak

    2017-12-01

    As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.

  6. Hadron cancer therapy complex using nonscaling fixed field alternating gradient accelerator and gantry design

    Directory of Open Access Journals (Sweden)

    E. Keil

    2007-05-01

    Full Text Available Nonscaling fixed field alternating gradient (FFAG rings for cancer hadron therapy offer reduced physical aperture and large dynamic aperture as compared to scaling FFAGs. The variation of tune with energy implies the crossing of resonances during acceleration. Our design avoids intrinsic resonances, although imperfection resonances must be crossed. We consider a system of three nonscaling FFAG rings for cancer therapy with 250 MeV protons and 400   MeV/u carbon ions. Hadrons are accelerated in a common radio frequency quadrupole and linear accelerator, and injected into the FFAG rings at v/c=0.1294. H^{+}/C^{6+} ions are accelerated in the two smaller/larger rings to 31 and 250  MeV/68.8 and 400   MeV/u kinetic energy, respectively. The lattices consist of doublet cells with a straight section for rf cavities. The gantry with triplet cells accepts the whole required momentum range at fixed field. This unique design uses either high-temperature superconductors or superconducting magnets reducing gantry magnet size and weight. Elements with a variable field at the beginning and at the end set the extracted beam at the correct position for a range of energies.

  7. Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

    Science.gov (United States)

    Trinh, Greenfield; Copplestone, Grace; O'Connor, Molly; Hu, Steven; Nowak, Sebastian; Cheung, Kenneth; Jenett, Benjamin; Cellucci, Daniel

    2017-01-01

    This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called "digital materials." We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

  8. Port Card Module

    International Nuclear Information System (INIS)

    Utes, M.

    1994-01-01

    The Port Card will be one link in the data acquisition system for the D0 Silicon Vertex Detector. This system consists of the following parts, starting at the detector: Silicon strip detectors are mounted in a spaceframe and wire-bonded to custom bare-die integrated circuits (SVX-II chips) that digitize the charge collected by the strips. The 128-channel chips are mounted on a High-Density Interconnect (HDI) that consists of a small flex circuit that routes control signals and eight data bits for each of three to ten chips onto a common data bus. A cable then routes this bus approximately thirty feet out from the detector to the Port Card. The Port Card houses a commercial chipset that serializes the data in real time and converts the signal into laser light impulses that are then transmitted through a multi-mode optical fiber about 150 feet to a Silicon Acquisition and Readout board (SAR). Here, the data is transformed back to parallel electrical signals that are stored in one of several banks of FIFO memories. The FIFOs place their data onto the VME backplane to a VME Buffer Driver (VBD) which stores the event data in buffers for eventual readout over a thirty-two signal ribbon cable to the Level Two Computers and subsequent tape storage. Control and sequencing of the whole operation starts with the Silicon Acquisition/Readout Controller (SARC) working in tandem with the D0 Clock System. The SARC resides in the same VME crate as the SARs, and transforms signals from the Trigger System into control codes distributed to the various Port Cards via optical fibers operating at 53 Mb/s. It is through these control codes that data taking operations such as data-acquisition, digitization, readout, and various resets can be carried out. The Port Card receives the control codes and manipulates the SVX-II chips in the proper way to effect proper data taking. There will be a total of about 700,000 channels, which translates into about 5580 SVX-II chips, 66 to 100 Port Cards

  9. Rotating flow

    CERN Document Server

    Childs, Peter R N

    2010-01-01

    Rotating flow is critically important across a wide range of scientific, engineering and product applications, providing design and modeling capability for diverse products such as jet engines, pumps and vacuum cleaners, as well as geophysical flows. Developed over the course of 20 years' research into rotating fluids and associated heat transfer at the University of Sussex Thermo-Fluid Mechanics Research Centre (TFMRC), Rotating Flow is an indispensable reference and resource for all those working within the gas turbine and rotating machinery industries. Traditional fluid and flow dynamics titles offer the essential background but generally include very sparse coverage of rotating flows-which is where this book comes in. Beginning with an accessible introduction to rotating flow, recognized expert Peter Childs takes you through fundamental equations, vorticity and vortices, rotating disc flow, flow around rotating cylinders and flow in rotating cavities, with an introduction to atmospheric and oceanic circul...

  10. Rotational seismology

    Science.gov (United States)

    Lee, William H K.

    2016-01-01

    Rotational seismology is an emerging study of all aspects of rotational motions induced by earthquakes, explosions, and ambient vibrations. It is of interest to several disciplines, including seismology, earthquake engineering, geodesy, and earth-based detection of Einstein’s gravitation waves.Rotational effects of seismic waves, together with rotations caused by soil–structure interaction, have been observed for centuries (e.g., rotated chimneys, monuments, and tombstones). Figure 1a shows the rotated monument to George Inglis observed after the 1897 Great Shillong earthquake. This monument had the form of an obelisk rising over 19 metres high from a 4 metre base. During the earthquake, the top part broke off and the remnant of some 6 metres rotated about 15° relative to the base. The study of rotational seismology began only recently when sensitive rotational sensors became available due to advances in aeronautical and astronomical instrumentations.

  11. HomePort

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2009-01-01

    In the last couple of year's computer based home control systems are getting more and more common in modern homes. For instance these systems take care of light control, heat control and security systems.  The latest trend is to use wireless communication like Z-Wave and ZigBee to interconnect...... different components in these systems. One of the characteristics is that each system, like for instance heat and light, has their own specific way of using the communication system.   This paper describes a way to connect different home control systems through an intelligent gateway, called a Home......Port. The HomePort consists of a number of Subsystem communication drivers, a virtual communication layer, an interpreter and a PC- based compiler for a high level control language, called GIL (Gateway intelligence language). The focus in this paper will be on the upper two layers in the Home...

  12. Port interface requirements

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    In a land-based reactor programme the Administration are usually confronted with a specific design in a particular environment. Safety and Reliability criteria necessary to the designer can be specified on the basis of acceptable risk to the population. However for the successful implementation of a nuclear ship programme on a broad commercial basis it is necessary to have agreed standards of risks from ships yet to be designed and agreed standards of acceptable risks to the population at likely ports of call yet to be specified, consulted, or agreed. At first sight it would seem that this double uncertainty must either lead to unnecessarily high safety standards for the ship or unacceptably conservative standards for berth selection. The paper discusses the problem and proposes a possible solution based on the concept of a 'Standard Port' and a 'Standard Ship' and indicates the level of risk implied by such a concept

  13. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  14. Precedent Research on Compact Laser-plasma based Gantry for Cancer Therapy

    International Nuclear Information System (INIS)

    Hee, Park Seong; Jeong, Young Uk; Lee, Ki Tae; Kim, Kyung Nam; Cha, Young Ho

    2012-03-01

    This is the precedent R and D to develop the technology of next generation compact particle cancer treatment system based on laser-plasma interaction and to deduce a big project. The subject of this project are the survey of application technology of laser-plasma based particle beam and the design of compact laser-plasma based gantry. The survey of characteristic of particle beam for cancer therapy and present status can be adapted to develop new system. The comparison between particle beams from the existing system and new one based on laser-plasma acceleration will be important to new design and design optimization. The project includes design of multi-dimensional laser transfer beamline, minimization of laser-plasma acceleration chamber, design of effective energy separation/selection system, and radiation safety and local shielding

  15. Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT

    International Nuclear Information System (INIS)

    Srivastava, Shiv P.; Das, Indra J.; Kumar, Arvind; Johnstone, Peter A.S.

    2011-01-01

    Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm 3 and 153.6 and 321.3 cm 3 , whereas OAR ranged between 8.3 and 47.8 cm 3 and 68.3 and 469.2 cm 3 , respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 ± 6.6% (p = 0.012) and 10.4 ± 13.6% (p = 0.140), and 14.6 ± 5.6% (p = 1.003E-5) and 12.6 ± 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases.

  16. Global rotation

    International Nuclear Information System (INIS)

    Rosquist, K.

    1980-01-01

    Global rotation in cosmological models is defined on an observational basis. A theorem is proved saying that, for rigid motion, the global rotation is equal to the ordinary local vorticity. The global rotation is calculated in the space-time homogeneous class III models, with Godel's model as a special case. It is shown that, with the exception of Godel's model, the rotation in these models becomes infinite for finite affine parameter values. In some directions the rotation changes sign and becomes infinite in a direction opposite to the local vorticity. The points of infinite rotation are identified as conjugate points along the null geodesics. The physical interpretation of the infinite rotation is discussed, and a comparison with the behaviour of the area distance at conjugate points is given. (author)

  17. A review of dry ports

    OpenAIRE

    Violeta Roso; Kent Lumsden

    2010-01-01

    The objective of this article is to present the previous research on the dry port concept and to review the world's existing dry ports, that is freight terminals that use the term ‘dry port’ in their name. Therefore, the purpose of this article is to clarify the concept by showing potential discrepancies or agreements between theory and practice. Starting from a literature review on the dry port concept, this article presents a review of existing dry ports in the world. A number of qualitativ...

  18. 360 PORT MDA - A Strategy to Improve Port Security

    Science.gov (United States)

    2006-09-01

    Participating Agencies (After: Executive Briefing..........................27 Table 6. Designated Joint Operations Center Participants (From: SAFE...Investigations CGIP Coast Guard Intelligence Program CHOC Charleston Harbor Operations Center CIO Command Intelligence Officer CMT Combating Maritime... EXECUTIVE SUMMARY Ports are critical to our economy and national security. Key hubs in the international trade network, U.S. ports accounted for more than

  19. VMAT optimization with dynamic collimator rotation.

    Science.gov (United States)

    Lyu, Qihui; O'Connor, Daniel; Ruan, Dan; Yu, Victoria; Nguyen, Dan; Sheng, Ke

    2018-04-16

    Although collimator rotation is an optimization variable that can be exploited for dosimetric advantages, existing Volumetric Modulated Arc Therapy (VMAT) optimization uses a fixed collimator angle in each arc and only rotates the collimator between arcs. In this study, we develop a novel integrated optimization method for VMAT, accounting for dynamic collimator angles during the arc motion. Direct Aperture Optimization (DAO) for Dynamic Collimator in VMAT (DC-VMAT) was achieved by adding to the existing dose fidelity objective an anisotropic total variation term for regulating the fluence smoothness, a binary variable for forming simple apertures, and a group sparsity term for controlling collimator rotation. The optimal collimator angle for each beam angle was selected using the Dijkstra's algorithm, where the node costs depend on the estimated fluence map at the current iteration and the edge costs account for the mechanical constraints of multi-leaf collimator (MLC). An alternating optimization strategy was implemented to solve the DAO and collimator angle selection (CAS). Feasibility of DC-VMAT using one full-arc with dynamic collimator rotation was tested on a phantom with two small spherical targets, a brain, a lung and a prostate cancer patient. The plan was compared against a static collimator VMAT (SC-VMAT) plan using three full arcs with 60 degrees of collimator angle separation in patient studies. With the same target coverage, DC-VMAT achieved 20.3% reduction of R50 in the phantom study, and reduced the average max and mean OAR dose by 4.49% and 2.53% of the prescription dose in patient studies, as compared with SC-VMAT. The collimator rotation co-ordinated with the gantry rotation in DC-VMAT plans for deliverability. There were 13 beam angles in the single-arc DC-VMAT plan in patient studies that requires slower gantry rotation to accommodate multiple collimator angles. The novel DC-VMAT approach utilizes the dynamic collimator rotation during arc

  20. Container Traffic In European Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2004-03-01

    Full Text Available Over the last fifteen years the European transport markethas witnessed a growth of container traffic which today reachesapproximately 50 million TEU per year. From 1997 to 2002,container traffic in the northern European ports increased from14 to 20.6 million TEU per year, in the ports of the westernMedite"anean from 6 to 10 million TEU per year, and in thenorthern Adriatic ports from 0. 69 to 0. 74 million TEU per year.The ports of the northern Adriatic are located in three states(Slovenia, Croatia and Italy with different statuses in relationto the common European market. In addition, different developmentlevels of these states are reflected in different levels ofinternational commercial exchange, the development of the existinginfrastructure and plans for the construction of new infrastructures.However, all three countries share a common goaltoincrease their competitiveness in comparison with the westemEuropean ports.

  1. Principles of subcutaneous port placement.

    Science.gov (United States)

    Gonda, Shaun J; Li, Ruizong

    2011-12-01

    The introduction of totally implantable subcutaneous devices in the early 1980s provided patients with secure, reliable venous access and also gave them the ability to move more freely and have a more normal lifestyle with these devices in place. The most common totally implantable device used today is the subcutaneous port. These ports consist of an injection port connected to a catheter. Ports provide a number of advantages compared with other venous catheters; the most important is the reduced risk of infection. These devices have significantly lower rates of infection than nontunneled and tunneled catheters. Additional advantages include less frequent irrigation and minimal home care, and they are less prone to environmental or cutaneous contamination when not being accessed. This article will focus on the placement of these ports. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Single port laparoscopic surgery

    DEFF Research Database (Denmark)

    Springborg, Henrik; Istre, Olav

    2012-01-01

    LESS, or laparo-endoscopic single site surgery, is a promising new method in minimally invasive surgery. An increasing number of surgical procedures are being performed using this technique, however, its large-scale adoption awaits results of prospective randomized controlled studies confirming...... potential benefits. Theoretically, cosmetic outcomes, postoperative pain and complication rates could be improved with use of single site surgery. This study describes introduction of the method in a private hospital in Denmark, in which 40 patients have been treated for benign gynecologic conditions....... Although the operations described are the first of their kind reported in Denmark, favorable operating times and very low complication rates are seen. It is the authors' opinion that in addition to being feasible for hysterectomy, single port laparoscopy may become the preferred method for many simple...

  3. Rotating Wavepackets

    Science.gov (United States)

    Lekner, John

    2008-01-01

    Any free-particle wavepacket solution of Schrodinger's equation can be converted by differentiations to wavepackets rotating about the original direction of motion. The angular momentum component along the motion associated with this rotation is an integral multiple of [h-bar]. It is an "intrinsic" angular momentum: independent of origin and…

  4. Rotating dryer

    International Nuclear Information System (INIS)

    Noe, C.

    1984-01-01

    Products to dry are introduced inside a rotating tube placed in an oven, the cross section of the tube is an arc of spiral. During clockwise rotation of the tube products are maintained inside and mixed, during anticlockwise products are removed. Application is made to drying of radioactive wastes [fr

  5. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    Zwan, B J [Central Coast Cancer Centre, Gosford, NSW (Australia); University of Newcastle, Newcastle, NSW (Australia); Barnes, M; Greer, P B [University of Newcastle, Newcastle, NSW (Australia); Calvary Mater Hospital, Newcastle, NSW (Australia); Hindmarsh, J; Seymour, E [Central Coast Cancer Centre, Gosford, NSW (Australia); O’Connor, D J [University of Newcastle, Newcastle, NSW (Australia); Keall, P J [University of Sydney, Camperdown, NSW (Australia)

    2016-06-15

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  6. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Zwan, B J; Barnes, M; Greer, P B; Hindmarsh, J; Seymour, E; O’Connor, D J; Keall, P J

    2016-01-01

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  7. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  8. Craniospinal treatment with IMRT multi-isocentric and image-guided linear accelerator based on Gantry; Tratamiento craneoespinal multi-isocentrico con IMRT y guiado por imagen en acelerador lineal basado en Gantry

    Energy Technology Data Exchange (ETDEWEB)

    Sanz Beltran, M.; Caballero Perea, B.; Rodriguez Rodriguez, C.; Arminio Diaz, E.; Lopez Fernandez, A.; Gomez Fervienza, J. R.; Crespo Diez, P.; Cantarero Valenzuela, N.; Alvarez Sanchez, M.; Martin Martin, G.; Gomez Fervienza, J. r.; Crespo Diez, P.; Cantarero Valenzuela, N.; Alvarez Sanchez, M.; Martin Martin, G.

    2011-07-01

    The objective is the realization of craniospinal treatment with a linear accelerator equipped with gantry based on MLC, carbon fiber table and Image Guided capability. The great length of treatment (patient l, 80m in height) was a great difficulty for want of full length of the longitudinal movement of the table to adequately cover the PTV, plus free metallic screws fastening the head of the table extender preventing further incidents.

  9. Operator control systems and methods for swing-free gantry-style cranes

    Science.gov (United States)

    Feddema, John T.; Petterson, Ben J.; Robinett, III, Rush D.

    1998-01-01

    A system and method for eliminating swing motions in gantry-style cranes while subject to operator control is presented. The present invention comprises an infinite impulse response ("IIR") filter and a proportional-integral ("PI") feedback controller (50). The IIR filter receives input signals (46) (commanded velocity or acceleration) from an operator input device (45) and transforms them into output signals (47) in such a fashion that the resulting motion is swing free (i.e., end-point swinging prevented). The parameters of the IIR filter are updated in real time using measurements from a hoist cable length encoder (25). The PI feedback controller compensates for modeling errors and external disturbances, such as wind or perturbations caused by collision with objects. The PI feedback controller operates on cable swing angle measurements provided by a cable angle sensor (27). The present invention adjusts acceleration and deceleration to eliminate oscillations. An especially important feature of the present invention is that it compensates for variable-length cable motions from multiple cables attached to a suspended payload.

  10. Improved scintimammography using a high-resolution camera mounted on an upright mammography gantry

    International Nuclear Information System (INIS)

    Itti, Emmanuel; Patt, Bradley E.; Diggles, Linda E.; MacDonald, Lawrence; Iwanczyk, Jan S.; Mishkin, Fred S.; Khalkhali, Iraj

    2003-01-01

    99m Tc-sestamibi scintimammography (SMM) is a useful adjunct to conventional X-ray mammography (XMM) for the assessment of breast cancer. An increasing number of studies has emphasized fair sensitivity values for the detection of tumors >1 cm, compared to XMM, particularly in situations where high glandular breast densities make mammographic interpretation difficult. In addition, SMM has demonstrated high specificity for cancer, compared to various functional and anatomic imaging modalities. However, large field-of-view (FOV) gamma cameras are difficult to position close to the breasts, which decreases spatial resolution and subsequently, the sensitivity of detection for tumors 2 FOV and an array of 2x2x6 mm 3 discrete crystals coupled to a photon-sensitive photomultiplier tube readout. This camera is mounted on a mammography gantry allowing upright imaging, medial positioning and use of breast compression. Preliminary data indicates significant enhancement of spatial resolution by comparison with standard imaging in the first 10 patients. Larger series will be needed to conclude on sensitivity/specificity issues

  11. Improved scintimammography using a high-resolution camera mounted on an upright mammography gantry

    Energy Technology Data Exchange (ETDEWEB)

    Itti, Emmanuel; Patt, Bradley E.; Diggles, Linda E.; MacDonald, Lawrence; Iwanczyk, Jan S.; Mishkin, Fred S.; Khalkhali, Iraj E-mail: nephrad@aol.com

    2003-01-21

    {sup 99m}Tc-sestamibi scintimammography (SMM) is a useful adjunct to conventional X-ray mammography (XMM) for the assessment of breast cancer. An increasing number of studies has emphasized fair sensitivity values for the detection of tumors >1 cm, compared to XMM, particularly in situations where high glandular breast densities make mammographic interpretation difficult. In addition, SMM has demonstrated high specificity for cancer, compared to various functional and anatomic imaging modalities. However, large field-of-view (FOV) gamma cameras are difficult to position close to the breasts, which decreases spatial resolution and subsequently, the sensitivity of detection for tumors <1 cm. New dedicated detectors featuring small FOV and increased spatial resolution have recently been developed. In this setting, improvement in tumor detection sensitivity, particularly with regard to small cancers is expected. At Division of Nuclear Medicine, Harbor-UCLA Medical Center, we have performed over 2000 SMM within the last 9 years. We have recently used a dedicated breast camera (LumaGEM) featuring a 12.8x12.8 cm{sup 2} FOV and an array of 2x2x6 mm{sup 3} discrete crystals coupled to a photon-sensitive photomultiplier tube readout. This camera is mounted on a mammography gantry allowing upright imaging, medial positioning and use of breast compression. Preliminary data indicates significant enhancement of spatial resolution by comparison with standard imaging in the first 10 patients. Larger series will be needed to conclude on sensitivity/specificity issues.

  12. Technical Note: Kinect V2 surface filtering during gantry motion for radiotherapy applications.

    Science.gov (United States)

    Nazir, Souha; Rihana, Sandy; Visvikis, Dimitris; Fayad, Hadi

    2018-04-01

    In radiotherapy, the Kinect V2 camera, has recently received a lot of attention concerning many clinical applications including patient positioning, respiratory motion tracking, and collision detection during the radiotherapy delivery phase. However, issues associated with such applications are related to some materials and surfaces reflections generating an offset in depth measurements especially during gantry motion. This phenomenon appears in particular when the collimator surface is observed by the camera; resulting in erroneous depth measurements, not only in Kinect surfaces itself, but also as a large peak when extracting a 1D respiratory signal from these data. In this paper, we proposed filtering techniques to reduce the noise effect in the Kinect-based 1D respiratory signal, using a trend removal filter, and in associated 2D surfaces, using a temporal median filter. Filtering process was validated using a phantom, in order to simulate a patient undergoing radiotherapy treatment while having the ground truth. Our results indicate a better correlation between the reference respiratory signal and its corresponding filtered signal (Correlation coefficient of 0.76) than that of the nonfiltered signal (Correlation coefficient of 0.13). Furthermore, surface filtering results show a decrease in the mean square distance error (85%) between the reference and the measured point clouds. This work shows a significant noise compensation and surface restitution after surface filtering and therefore a potential use of the Kinect V2 camera for different radiotherapy-based applications, such as respiratory tracking and collision detection. © 2018 American Association of Physicists in Medicine.

  13. Design of 6 MeV X-band electron linac for dual-head gantry radiotherapy system

    Science.gov (United States)

    Shin, Seung-wook; Lee, Seung-Hyun; Lee, Jong-Chul; Kim, Huisu; Ha, Donghyup; Ghergherehchi, Mitra; Chai, Jongseo; Lee, Byung-no; Chae, Moonsik

    2017-12-01

    A compact 6 MeV electron linac is being developed at Sungkyunkwan University, in collaboration with the Korea atomic energy research institute (KAERI). The linac will be used as an X-ray source for a dual-head gantry radiotherapy system. X-band technology has been employed to satisfy the size requirement of the dual-head gantry radiotherapy machine. Among the several options available, we selected a pi/2-mode, standing-wave, side-coupled cavity. This choice of radiofrequency (RF) cavity design is intended to enhance the shunt impedance of each cavity in the linac. An optimum structure of the RF cavity with a high-performance design was determined by applying a genetic algorithm during the optimization procedure. This paper describes the detailed design process for a single normal RF cavity and the entire structure, including the RF power coupler and coupling cavity, as well as the beam dynamics results.

  14. Optimal Performance of a Nonlinear Gantry Crane System via Priority-based Fitness Scheme in Binary PSO Algorithm

    International Nuclear Information System (INIS)

    Jaafar, Hazriq Izzuan; Ali, Nursabillilah Mohd; Selamat, Nur Asmiza; Kassim, Anuar Mohamed; Mohamed, Z; Abidin, Amar Faiz Zainal; Jamian, J J

    2013-01-01

    This paper presents development of an optimal PID and PD controllers for controlling the nonlinear gantry crane system. The proposed Binary Particle Swarm Optimization (BPSO) algorithm that uses Priority-based Fitness Scheme is adopted in obtaining five optimal controller gains. The optimal gains are tested on a control structure that combines PID and PD controllers to examine system responses including trolley displacement and payload oscillation. The dynamic model of gantry crane system is derived using Lagrange equation. Simulation is conducted within Matlab environment to verify the performance of system in terms of settling time (Ts), steady state error (SSE) and overshoot (OS). This proposed technique demonstrates that implementation of Priority-based Fitness Scheme in BPSO is effective and able to move the trolley as fast as possible to the various desired position

  15. Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator.

    Science.gov (United States)

    O'Brien, Ricky T; Stankovic, Uros; Sonke, Jan-Jakob; Keall, Paul J

    2017-06-07

    Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency, in response to changes in the patient's real-time respiratory signal, the imaging dose can be reduced by 50-70%. RMG-4DCBCT optimally computes a patient specific gantry trajectory to eliminate streaking artefacts and projection clustering that is inherent in 4DCBCT imaging. The gantry trajectory is continuously updated as projection data is acquired and the patient's breathing changes. The aim of this study was to realise RMG-4DCBCT for the first time on a linear accelerator. To change the gantry speed in real-time a potentiometer under microcontroller control was used to adjust the current supplied to an Elekta Synergy's gantry motor. A real-time feedback loop was developed on the microcontroller to modulate the gantry speed and projection acquisition in response to the real-time respiratory signal so that either 40, RMG-4DCBCT 40 , or 60, RMG-4DCBCT 60 , uniformly spaced projections were acquired in 10 phase bins. Images of the CIRS dynamic Thorax phantom were acquired with sinusoidal breathing periods ranging from 2 s to 8 s together with two breathing traces from lung cancer patients. Image quality was assessed using the contrast to noise ratio (CNR) and edge response width (ERW). For the average patient, with a 3.8 s breathing period, the imaging time and image dose were reduced by 37% and 70% respectively. Across all respiratory rates, RMG-4DCBCT 40 had a CNR in the range of 6.5 to 7.5, and RMG-4DCBCT 60 had a CNR between 8.7 and 9.7, indicating that RMG-4DCBCT allows consistent and controllable CNR. In comparison, the CNR for conventional 4DCBCT drops from 20.4 to 6.2 as the breathing rate increases from 2 s to 8 s. With RMG-4DCBCT

  16. More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSI

    International Nuclear Information System (INIS)

    Lin Shixiong; Boehringer, Terence; Coray, Adolf; Grossmann, Martin; Pedroni, Eros

    2009-01-01

    Purpose: The beam monitoring equipments developed for the first PSI spot scanning proton therapy facility, Gantry 1, have been successfully used for more than 10 years. The purpose of this article is to summarize the author's experience in the beam monitoring technique for dynamic proton scanning. Methods: The spot dose delivery and verification use two independent beam monitoring and computer systems. In this article, the detector construction, electronic system, dosimetry, and quality assurance results are described in detail. The beam flux monitor is calibrated with a Faraday cup. The beam position monitoring is realized by measuring the magnetic fields of deflection magnets with Hall probes before applying the spot and by checking the beam position and width with an ionization strip chamber after the spot delivery. Results: The results of thimble ionization chamber dosimetry measurements are reproducible (with a mean deviation of less than 1% and a standard deviation of 1%). The resolution in the beam position measurement is of the order of a tenth of a millimeter. The tolerance of the beam position delivery and monitoring during scanning is less than 1.5 mm. Conclusions: The experiences gained with the successful operation of Gantry 1 represent a unique and solid background for the development of a new system, Gantry 2, in order to perform new advanced scanning techniques.

  17. More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSI

    Energy Technology Data Exchange (ETDEWEB)

    Lin Shixiong; Boehringer, Terence; Coray, Adolf; Grossmann, Martin; Pedroni, Eros [Center for Proton Therapy, Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland)

    2009-11-15

    Purpose: The beam monitoring equipments developed for the first PSI spot scanning proton therapy facility, Gantry 1, have been successfully used for more than 10 years. The purpose of this article is to summarize the author's experience in the beam monitoring technique for dynamic proton scanning. Methods: The spot dose delivery and verification use two independent beam monitoring and computer systems. In this article, the detector construction, electronic system, dosimetry, and quality assurance results are described in detail. The beam flux monitor is calibrated with a Faraday cup. The beam position monitoring is realized by measuring the magnetic fields of deflection magnets with Hall probes before applying the spot and by checking the beam position and width with an ionization strip chamber after the spot delivery. Results: The results of thimble ionization chamber dosimetry measurements are reproducible (with a mean deviation of less than 1% and a standard deviation of 1%). The resolution in the beam position measurement is of the order of a tenth of a millimeter. The tolerance of the beam position delivery and monitoring during scanning is less than 1.5 mm. Conclusions: The experiences gained with the successful operation of Gantry 1 represent a unique and solid background for the development of a new system, Gantry 2, in order to perform new advanced scanning techniques.

  18. Developing the port of Belawan as a modern and international port

    Science.gov (United States)

    Many, N.

    2018-03-01

    This study discusses the processes of government to pass the port development plan in Indonesia with the Port of Belawan and its port expansion as the study case. The study uses a descriptive approach by reviewing and analyzing some of relevant literature as the sources. It also reviews and examines the port development theoretical concepts and models giving attention to the international hub port models resulted from the previous studies. The international hub port aspects assessed to be further applied and compared to the actual situation of the Port of Belawan. This process draws the conclusion on which concept and model the port classified, followed by some recommendations concerning the necessary actions to be taken. The results show that: (1) The port planning regulated in port master plan is the guideline and foundation to implement the port development; (2) Spatial and zoning plan regulations are very important in the preparation, planning, and implementation of port development; (3) It has not provided the necessary facilities and criteria of the global hub port model has not been met completely. The port is strategic to be completely developed as the regional hub port to compete with the major ports of neighboring countries. Eventually, this study requires further analysis to examine the economic feasibility of the Port of Belawan in more comprehensive way functioning as an international hub port along with the ongoing development of Kuala Tanjung Port to achieve its ultimate objectives, among other things, the port effectiveness, efficiency, and competitiveness.

  19. Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management

    Energy Technology Data Exchange (ETDEWEB)

    Frellesen, Claudia; Boettcher, Marie; Wichmann, Julian L.; Drieske, Martina; Kerl, J. Matthias; Lehnert, Thomas [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Nau, Christoph; Geiger, Emmanuel; Wutzler, Sebastian [Department of Trauma, Reconstructive and Hand Surgery, Clinic of the Goethe University, Frankfurt (Germany); Ackermann, Hanns [Department of Biostatistics and Mathematical Modelling, Clinic of the Goethe University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas J. [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Bauer, Ralf W., E-mail: ralfwbauer@aol.com [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany)

    2015-01-15

    Highlights: • A sliding gantry trauma room CT solution facilitates significantly faster polytrauma management. • Faster and more efficient resumption of regularly scheduled patients due to a two room solution is supported. • Sliding gantry CT achieves the same patient throughput as two separate conventional CT devices. - Abstract: Objectives: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. Materials and methods: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. Results: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power. Conclusions: Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units.

  20. Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management

    International Nuclear Information System (INIS)

    Frellesen, Claudia; Boettcher, Marie; Wichmann, Julian L.; Drieske, Martina; Kerl, J. Matthias; Lehnert, Thomas; Nau, Christoph; Geiger, Emmanuel; Wutzler, Sebastian; Ackermann, Hanns; Vogl, Thomas J.; Bauer, Ralf W.

    2015-01-01

    Highlights: • A sliding gantry trauma room CT solution facilitates significantly faster polytrauma management. • Faster and more efficient resumption of regularly scheduled patients due to a two room solution is supported. • Sliding gantry CT achieves the same patient throughput as two separate conventional CT devices. - Abstract: Objectives: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. Materials and methods: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. Results: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power. Conclusions: Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units

  1. Status of proton treatment facility at National Cancer Center, Kashiwa

    International Nuclear Information System (INIS)

    Tachikawa, T.; Kohmura, I.; Kataoka, S.; Nonaka, H.; Kimura, T.; Sato, T.; Nishio, T.; Shimbo, M.; Ogino, T.; Ikeda, H.

    2001-01-01

    Proton treatment facility at National Cancer Center Hospital East (Kashiwa) has two rotating gantry ports and one horizontal fixed port. In order to provide the same dose distribution at different gantry angles, the beam optics from the accelerator (235 MeV cyclotron) to the entrance of nozzle is specially tuned. Recently developed automatic tuning method of beam alignment can realize a sequential treatment at three irradiation ports. (author)

  2. Predictive Parameters of Symptomatic Hematochezia Following 5-Fraction Gantry-Based SABR in Prostate Cancer

    International Nuclear Information System (INIS)

    Musunuru, Hima Bindu; Davidson, Melanie; Cheung, Patrick; Vesprini, Danny; Liu, Stanley; Chung, Hans; Chu, William; Mamedov, Alexandre; Ravi, Ananth; D'Alimonte, Laura; Commisso, Kristina; Helou, Joelle; Deabreu, Andrea; Zhang, Liying; Loblaw, Andrew

    2016-01-01

    Purpose: This study identified predictors of high-grade late hematochezia (HH) following 5-fraction gantry-based stereotactic ablative radiation therapy (SABR). Methods and Materials: Hematochezia data for 258 patients who received 35 to 40 Gy SABR in 5-fractions as part of sequential phase 2 prospective trials was retrieved. Grade 2 or higher late rectal bleeding was labeled HH. Hematochezia needing steroid suppositories, 4% formalin, or 1 to 2 sessions of argon plasma coagulation (APC) was labeled grade 2. More than 2 sessions of APC, blood transfusion, or a course of hyperbaric oxygen was grade 3 and development of visceral fistula, grade 4. Various dosimetric and clinical factors were analyzed using univariate and multivariate analyses. Receiver operating characteristic (ROC) curve analysis and recursive partitioning analysis were used to determine clinically valid cut-off points and identify risk groups, respectively. Results: HH was observed in 19.4%, grade ≥3 toxicity in 3.1%. Median follow-up was 29.7 months (interquartile range [IQR]: 20.6-61.7) Median time to develop HH was 11.7 months (IQR: 9.0-15.2) from the start of radiation. At 2 years, cumulative HH was 4.9%, 27.2%, and 42.1% in patients who received 35 Gy to prostate (4-mm planning target volume [PTV] margin), 40 Gy to prostate (5-mm PTV margin), and 40 Gy to prostate/seminal vesicles (5-mm PTV margin), respectively (P 30%. Conclusions: Rectal V38 and 2 clinical factors were strong predictors of HH following 5-fraction SABR. Planning constraints should keep rectal V38 below 2.0 cm"3.

  3. Ergon-trial: ergonomic evaluation of single-port access versus three-port access video-assisted thoracic surgery.

    Science.gov (United States)

    Bertolaccini, Luca; Viti, Andrea; Terzi, Alberto

    2015-10-01

    Single-port access video-assisted thoracic surgery (VATS), a technique progressively developed from the standard three-port approach in minimally invasive surgery, offers ergonomic advantages but also new challenges for the surgeon. We compared the ergonomics of three-port versus single-port VATS. Posture analysis of surgeons was evaluated during 100 consecutive VATS wedge resections (50 triportal vs. 50 uniportal). Technically demanding procedures (major lung resection) were excluded. Operating table height, monitor height, distance and inclination were adjusted according to operator preference. Body posture was assessed by measuring head-trunk axial rotation and head flexion. Perceived physical strain was self-evaluated on the Borg Category Ratio (CR-10) scale. Mental workload was assessed with the National Aeronautics Space Administration-Task Load indeX (NASA-TLX), a multidimensional tool that rates workloads on six scales (mental, physical and temporal demand; effort; performance; frustration). All procedures were completed without complications. Head-trunk axial rotation was significantly reduced and neck flexion significantly improved in uniportal VATS. Viewing direction significantly declined (p = 0.01), body posture as measured on the Borg CR-10 scale was perceived as more stressful and the NASA-TLX score for overall workload was higher (p = 0.04) during triportal VATS. The NASA-TLX score for frustration was higher with uniportal VATS (p = 0.02), but the score for physical demand was higher in triportal VATS (p = 0.006). The surgeon can maintain a more neutral body posture during uniportal VATS by standing straight and facing the monitor with only minimal neck extension/rotation; however, frustration is greater than with triportal VATS.

  4. Case Studies: Improving Environmental Performance and Economic Prosperity at Ports and in Near-Port Communities

    Science.gov (United States)

    Case Study links for improving environmental performance and economic prosperity at ports and in near-port communities. Case studies on equipment upgrades, jobs and benefits, land use and transportation, port-community engagement, and citizen science.

  5. Rotating preventers

    International Nuclear Information System (INIS)

    Tangedahl, M.J.; Stone, C.R.

    1992-01-01

    This paper reports that recent changes in the oil and gas industry and ongoing developments in horizontal and underbalanced drilling necessitated development of a better rotating head. A new device called the rotating blowout preventer (RBOP) was developed by Seal-Tech. It is designed to replace the conventional rotating control head on top of BOP stacks and allows drilling operations to continue even on live (underbalanced) wells. Its low wear characteristics and high working pressure (1,500 psi) allow drilling rig crews to drill safely in slightly underbalanced conditions or handle severe well control problems during the time required to actuate other BOPs in the stack. Drilling with a RBOP allows wellbores to be completely closed in tat the drill floor rather than open as with conventional BOPs

  6. Earth Rotation

    Science.gov (United States)

    Dickey, Jean O.

    1995-01-01

    The study of the Earth's rotation in space (encompassing Universal Time (UT1), length of day, polar motion, and the phenomena of precession and nutation) addresses the complex nature of Earth orientation changes, the mechanisms of excitation of these changes and their geophysical implications in a broad variety of areas. In the absence of internal sources of energy or interactions with astronomical objects, the Earth would move as a rigid body with its various parts (the crust, mantle, inner and outer cores, atmosphere and oceans) rotating together at a constant fixed rate. In reality, the world is considerably more complicated, as is schematically illustrated. The rotation rate of the Earth's crust is not constant, but exhibits complicated fluctuations in speed amounting to several parts in 10(exp 8) [corresponding to a variation of several milliseconds (ms) in the Length Of the Day (LOD) and about one part in 10(exp 6) in the orientation of the rotation axis relative to the solid Earth's axis of figure (polar motion). These changes occur over a broad spectrum of time scales, ranging from hours to centuries and longer, reflecting the fact that they are produced by a wide variety of geophysical and astronomical processes. Geodetic observations of Earth rotation changes thus provide insights into the geophysical processes illustrated, which are often difficult to obtain by other means. In addition, these measurements are required for engineering purposes. Theoretical studies of Earth rotation variations are based on the application of Euler's dynamical equations to the problem of finding the response of slightly deformable solid Earth to variety of surface and internal stresses.

  7. Cooperation Performance Evaluation between Seaport and Dry Port; Case of Qingdao Port and Xi'an Port

    Directory of Open Access Journals (Sweden)

    Jian Li

    2014-12-01

    Full Text Available Along with the drastic competition among ports, the strive for the vast economic hinterland and the supply of goods have become strategic problems for port operators. At the same time, port enterprises are paying more and more attention to the construction of dry ports. This article establishes the port cooperation performance evaluation index based on the balanced score card method and uses the grey relational degree method to evaluate the cooperation performance between seaports and dry ports. Finally using Qingdao port and Xi'an port as an example, and Zhengzhou port and Lanzhou port as benchmarks, the application of this evaluation method is introduced in detail. The conclusion reveals that cooperation between Qingdao port and Xi'an port has deficiencies in customer satisfaction, financial cooperation and non-market tools. Alongside this, the author proposes related issues about information management in the supply chain, competition position and the scope of hinterland. This article, combined with the related theory of supply chain and performance evaluation, puts forward a set of relatively complete cooperation performance evaluations between seaports and dry ports, which provide scientific theory support for better cooperation.

  8. Predictive Parameters of Symptomatic Hematochezia Following 5-Fraction Gantry-Based SABR in Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Musunuru, Hima Bindu [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Davidson, Melanie [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Medical Physics, Odette Cancer Centre, Toronto, Ontario (Canada); Cheung, Patrick; Vesprini, Danny; Liu, Stanley; Chung, Hans; Chu, William [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Mamedov, Alexandre [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Ravi, Ananth [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Medical Physics, Odette Cancer Centre, Toronto, Ontario (Canada); D' Alimonte, Laura [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Commisso, Kristina [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Helou, Joelle [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Deabreu, Andrea [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Zhang, Liying [MacroStat, Inc, Toronto, Ontario (Canada); Loblaw, Andrew, E-mail: andrew.loblaw@sunnybrook.ca [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Department of Health Policy, Measurement and Evaluation, University of Toronto, Toronto, Ontario (Canada)

    2016-04-01

    Purpose: This study identified predictors of high-grade late hematochezia (HH) following 5-fraction gantry-based stereotactic ablative radiation therapy (SABR). Methods and Materials: Hematochezia data for 258 patients who received 35 to 40 Gy SABR in 5-fractions as part of sequential phase 2 prospective trials was retrieved. Grade 2 or higher late rectal bleeding was labeled HH. Hematochezia needing steroid suppositories, 4% formalin, or 1 to 2 sessions of argon plasma coagulation (APC) was labeled grade 2. More than 2 sessions of APC, blood transfusion, or a course of hyperbaric oxygen was grade 3 and development of visceral fistula, grade 4. Various dosimetric and clinical factors were analyzed using univariate and multivariate analyses. Receiver operating characteristic (ROC) curve analysis and recursive partitioning analysis were used to determine clinically valid cut-off points and identify risk groups, respectively. Results: HH was observed in 19.4%, grade ≥3 toxicity in 3.1%. Median follow-up was 29.7 months (interquartile range [IQR]: 20.6-61.7) Median time to develop HH was 11.7 months (IQR: 9.0-15.2) from the start of radiation. At 2 years, cumulative HH was 4.9%, 27.2%, and 42.1% in patients who received 35 Gy to prostate (4-mm planning target volume [PTV] margin), 40 Gy to prostate (5-mm PTV margin), and 40 Gy to prostate/seminal vesicles (5-mm PTV margin), respectively (P<.0001). In the ROC analysis, volume of rectum receiving radiation dose of 38 Gy (V38) was a strong predictor of HH with an area under the curve of 0.65. In multivariate analysis, rectal V38 (≥2.0 cm{sup 3}; odds ratio [OR]: 4.7); use of anticoagulants in the follow-up period (OR: 6.5) and presence of hemorrhoids (OR: 2.7) were the strongest predictors. Recursive partitioning analysis showed rectal V38 < 2.0 cm{sup 3}, and use of anticoagulants or rectal V38 ≥ 2.0 cm{sup 3} plus 1 other risk factor resulted in an HH risk of >30%. Conclusions: Rectal V38 and 2

  9. SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

    International Nuclear Information System (INIS)

    Partain, L; Kwon, J; Boyd, D; Rottmann, J; Berbeco, R; Zentai, G

    2015-01-01

    Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L

  10. SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

    Energy Technology Data Exchange (ETDEWEB)

    Partain, L; Kwon, J; Boyd, D [TeleSecurity Sciences, Las Vegas, NV (United States); Rottmann, J; Berbeco, R [Brigham and Woman’s Hospital, Boston, MA (United States); Zentai, G [Varian Medical Systems, Palo Alto, CA (United States)

    2015-06-15

    Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L

  11. TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Xu, H; Mutaf, Y; Prado, K [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

  12. WE-E-18A-11: Fluoro-Tomographic Images From Projections of On-Board Imager (OBI) While Gantry Is Moving

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Hu, E; Yu, C; Lasio, G [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2014-06-15

    Purpose: A method to generate a series of fluoro-tomographic images (FTI) of the slice of interest (SOI) from the projection images of the On-board imager (OBI) while gantry is moving is developed and tested. Methods: Tomographic image via background subtraction, TIBS has been published by our group. TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). We extended the idea to 4D TIBS, which enables to generate from the projection of different gantry angles. A set of background images for different angles are prepared. A background image at a given gantry angle is subtracted from the projection image at the same angle to generate a TIBS image. Then the TIBS image is converted to a reference angle. The 4D TIBS is the set of TIBS that originated from gantry angles other than the reference angle. Projection images of lung patients for CBCT acquisition are used to test the 4D TIBS. Results: Fluoroscopic images of a coronal plane of lung patients are acquired from the CBCT projections at different gantry angles and times. Change of morphology of hilar vessels due to breathing and heart beating are visible in the coronal plane, which are generated from the set of the projection images at gantry angles other than antero-posterior. Breathing surrogate or sorting process is not needed. Unlike tomosynthesis, FTI from 4D TIBS maintains the independence of each of the projections thereby reveals temporal variations within the SOI. Conclusion: FTI, fluoroscopic imaging of a SOI with x-ray projections, directly generated from the x-ray projection images at different gantry angles is tested with a lung case and proven feasible. This technique can be used for on-line imaging of moving targets. NIH Grant R01CA133539.

  13. Interface Circuit For Printer Port

    Science.gov (United States)

    Tucker, Jerry H.; Yadlowsky, Ann B.

    1991-01-01

    Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

  14. Effectively reducing emissions from ports

    Energy Technology Data Exchange (ETDEWEB)

    Fazlagic, Ismir; Martelin, Marcus; Skinner, Ryan

    2010-09-15

    Commercial ships calling at more and more ports worldwide can now turn off their diesel engines and tap into cleaner energy sources provided by electrical connections from shore. The technology to make this possible has been in place for over a decade. With a global technology standard due to be ratified by three technical bodies in 2010, high-voltage shore connections will soon get much more attention. Environmentally-minded ports, governments and shipowners are all tuning in to the benefits of supplying electricity to ships at berth. ABB presents the challenge, the technical solution and the business case for all parties involved.

  15. Port Harcourt Medical Journal, a paradigm shift | Eke | Port Harcourt ...

    African Journals Online (AJOL)

    Port Harcourt Medical Journal, a paradigm shift. N Eke. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4103/0795-3038.179439 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  16. The VisPort Project: Visualization of Port Logistics

    Science.gov (United States)

    Katsioloudis, Petros J.; Watson, Ginger

    2011-01-01

    There is concern about the diminishing availability of skilled personnel that can operate in the wide variety of disciplines associated with port operations. Increasing cargo volume, combined with a shrinking workforce, could potentially create alarming situations in the future, hence the motivation to publicize to current students the breadth and…

  17. Ports Primer: 7.1 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  18. Ports Primer: 7.0 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  19. Single port Billroth I gastrectomy

    Directory of Open Access Journals (Sweden)

    Jeremy R Huddy

    2013-01-01

    Full Text Available Introduction: Experience has allowed increasingly complex procedures to be undertaken by single port surgery. We describe a technique for single port Billroth I gastrectomy with a hand-sewn intracorporeal anastomosis in the resection of a benign tumour diagnosed incidentally on a background of cholelithiasis. Materials and Methods: Single port Billroth I gastrectomy and cholecystectomy was performed using a transumbilical quadport. Flexible tipped camera and straight conventional instruments were used throughout the procedure. The stomach was mobilised including a limited lymph node dissection and resection margins in the proximal antrum and duodenum were divided with a flexible tipped laparoscopic stapler. The lesser curve was reconstructed and an intracorporal hand sewn two layer end-to-end anastomosis was performed using unidirectional barbed sutures. Intraoperative endoscopy confirmed the anastomosis to be patent without leak. Results: Enteral feed was started on the day of surgery, increasing to a full diet by day 6. Analgesic requirements were a patient-controlled analgesia morphine pump for 4 postoperative days and paracetamol for 6 days. There were no postoperative complications and the patient was discharged on the eighth day. Histology confirmed gastric submucosal lipoma. Discussion: As technology improves more complex procedures are possible by single port laparoscopic surgery. In this case, flexible tipped cameras and unidirectional barbed sutures have facilitated an intracorporal hand-sewn two layer end-to-end anastomosis. Experience will allow such techniques to become mainstream.

  20. Port Harcourt Medical Journal: Submissions

    African Journals Online (AJOL)

    Port Harcourt Medical Journal (PMJ) is a general medical journal that will consider any original contribution that advances or illuminates medical science or ... The covering letter must include information on prior or duplicate publication and a statement of financial or other relationships that might lead to a conflict of interest.

  1. Optimal starting gantry angles using equiangular-spaced beams with intensity modulated radiation therapy for prostate cancer on RTOG 0126: A clinical study of 5 and 7 fields

    International Nuclear Information System (INIS)

    Potrebko, Peter S.; McCurdy, Boyd M.C.; Butler, James B.; El-Gubtan, Adel S.; Nugent, Zoann

    2007-01-01

    Background and Purpose: To investigate the effects of starting gantry angle and number of equiangular-spaced beams for prostate cancer radiotherapy on the Radiation Therapy Oncology Group (RTOG) 0126 protocol using intensity-modulated radiation therapy (IMRT). Materials and methods: Ten localized prostate cancer patients were prescribed to 79.2 Gy in 44 fractions. Static IMRT plans using five and seven equiangular-spaced beams were generated. The starting gantry angles were incremented by 5 o resulting in 15 (5 beams) and 11 (7 beams) plans per patient. Constant target coverage was ensured for all plans in order to isolate the variation in the rectal and bladder metrics as a function of starting gantry angle. Results: The variation with starting gantry angle in rectal metrics using 5 beams was statistically significant (p o and 50 o . Statistically insignificant differences were observed for the bladder metrics using 5 beams. There was little dosimetric variation in the rectal and bladder metrics with 7 beams. Nearly equivalent rectal V 75 Gy was achieved between 5 optimal equiangular-spaced beams starting at 20 o (class solution) and 7 equiangular-spaced beams starting at 0 o for most patients. Conclusions: The use of an optimal starting gantry angle for 5 equiangular-spaced beams, as indicated by a class solution in this study, will facilitate rectal sparing and can produce plans that are equivalent to those employing 7 equiangular-spaced beams

  2. Cyber security in ports: Business as usual

    OpenAIRE

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the ports and integrating the cyber risk into the physical security risk management processes and structures already in place within the ports. This also involves a higher degree of oversight by the P...

  3. COMPARATIVE ANALYSIS OF LEADING PORTS OF LATVIA: COMPETITIVENESS OF LIEPAJA PORT

    Directory of Open Access Journals (Sweden)

    Diāna Līduma

    2015-06-01

    Full Text Available There are 10 operating ports in Latvia and 3 of them – Liepaja, Ventspils and Riga ports are regarded as the leading commercial ports. Role of port operation in the economics of region and country is essential from the point of view of employment and entrepreneurship. This is based with data on investment of operation of Latvian ports in GDP, on average it is assessed to be 5-7% annually. In the context of employment, Liepaja Port gives work to 6.9% of human resources of the city. However, concern about the competitiveness of Liepaja Port influenced by the proximity of more developed competitive ports, technical possibilities of the port and dynamics of freight turnover has occurred in recent years. Therewith in framework of this article in the context of such criteria as location of ports and their technical parameters, volumes of freight, specialization and costs of ports, the operation of leading ports of Latvia is intercompared and analyzed by clarifying whether Liepaja Port is competitive among other ports of Latvia. Opinions of port experts on perspectives of port development and statistical data of ports from 2011-2013 are analyzed within the framework of the article. The aim of the research is to clarify the comparative advantages of ports of Latvia. The research revealed that the provision of competitiveness of Liepaja Port is to be related with application of the available free territories, advantages of location in relation to the Scandinavian market, and the necessity to develop the cooperation among ports of Latvia to offer joint freight acquisition, distributions and unified logistics solution and strengthen the position of ports in the circumstances of international competition.

  4. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  5. Multi-functional use of port areas

    NARCIS (Netherlands)

    Ros, R.; Taneja, P.; Vellinga, T.

    2012-01-01

    The core business of a port is handling vessels and cargo. In addition a landlord Port Authority invests in development of port areas. However, in view of the new trends such as stakeholders interests related to environment and sustainability, it is can be wise to reexamine the business portfolio

  6. Systems theory of interconnected port contact systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    Port-based network modeling of a large class of complex physical systems leads to dynamical systems known as port-Hamiltonian systems. The key ingredient of any port-Hamiltonian system is a power-conserving interconnection structure (mathematically formalized by the geometric notion of a Dirac

  7. 50 CFR 24.12 - Designated ports.

    Science.gov (United States)

    2010-10-01

    ...) The U.S. Department of Agriculture ports at Hilo, Hawaii, and Chicago, Illinois, are designated ports..., Florida Atlanta, Georgia Savannah, Georgia Agana, Guam Hilo, Hawaii Honolulu, Hawaii Wailuku, Maui, Hawaii... Orlando, Florida Honolulu, Hawaii New Orleans, Louisiana Hoboken, New Jersey (Port of New York) Jamaica...

  8. Notch filters for port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; van der Schaft, A.J.; Steinbuch, M.

    2012-01-01

    In this paper a standard notch filter is modeled in the port-Hamiltonian framework. By having such a port-Hamiltonian description it is proven that the notch filter is a passive system. The notch filter can then be interconnected with another (nonlinear) port-Hamiltonian system, while preserving the

  9. Conservative systems with ports on contact manifolds

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    In this paper we propose an extension of port Hamiltonian systems, called conservative systems with ports, which encompass systems arising from the Irreversible Thermodynamics. Firstly we lift a port Hamiltonian system from its state space manifold to the thermodynamic phase space to a contact

  10. Ports and Terminals : Planning and Functional Design

    NARCIS (Netherlands)

    Groenveld, R.; Velsink, H.

    1993-01-01

    1. Maritime transport, means and commodities 3. Principles of integrated port planning 4. Planning and design of a port's water areas 5. Port terminals - introduction 6. Conventional general cargo terminals 7. Container terminals 8. Oil & liquid gas terminals 9. Dry bulk cargo terminals 10. Fishery

  11. Starting manufacturing phase of ITER upper ports

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yuri, E-mail: yuri.utin@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fabritsiev, Sergey [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Giraud, Benoit; Guirao, Julio [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Koenig, Werner [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Kedrov, Igor; Kuzmin, Evgeny [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Levesy, Bruno; Martinez, Jean-Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Prebeck, Markus [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Privalova, Elena [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Ranzinger, Franz [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Savrukhin, Petr [Russian Federation ITER Domestic Agency, Kurchatov sq.1, 123182 Moscow (Russian Federation); Schiller, Thomas [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); and others

    2015-10-15

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  12. Starting manufacturing phase of ITER upper ports

    International Nuclear Information System (INIS)

    Utin, Yuri; Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James; Fabritsiev, Sergey; Giraud, Benoit; Guirao, Julio; Koenig, Werner; Kedrov, Igor; Kuzmin, Evgeny; Levesy, Bruno; Martinez, Jean-Marc; Prebeck, Markus; Privalova, Elena; Ranzinger, Franz; Savrukhin, Petr; Schiller, Thomas

    2015-01-01

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  13. Port-contact systems in bilateral telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2007-01-01

    In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a

  14. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    OpenAIRE

    Eka Wahyudi; Desi Permanasari

    2012-01-01

    Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC). Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer). Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port parale...

  15. 78 FR 36014 - Deepwater Port License Application: Liberty Natural Gas, LLC, Port Ambrose Deepwater Port

    Science.gov (United States)

    2013-06-14

    ... timeline for processing an application. When MarAd and USCG determine that an application contains the... that Port Ambrose falls within the proposed area of interest for the New York Power Authority Long Island-New York City Offshore Wind Project. This project will be acknowledged and considered in the...

  16. Maintaining and Researching Port Safety: A Case Study of the Port of Kaohsiung

    OpenAIRE

    Tseng, Po-Hsing.; Pilcher, Nick.

    2017-01-01

    Maintaining port safety in full conformity with IMO standards is a requisite for every port and country. To do this, understanding the challenges and human factors involved is key. To date, much research has shed valuable light on these factors and considered how to address them. One aspect that is often noted is that both maintaining port safety and researching port safety presents numerous challenges. This paper considers both these aspects in the context of a case study of port safety in K...

  17. Hub Status and Indexation of Container Ports

    Directory of Open Access Journals (Sweden)

    Yong-An Park

    2015-06-01

    This study develops two sub-indexes of port classification and capacity, and combines cases of these two sub-indexes into various types in order to find a proper port hub index. The paper demonstrates how different types of port hub index are useful measurements for evaluating outputs and inputs of container ports. In a case analysis we show that the indexes of period variables and lagged variables have more explanatory power with regard to changes of port throughputs and high correlation with inputs.

  18. A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new Gantry 2 at PSI

    International Nuclear Information System (INIS)

    Zenklusen, S M; Pedroni, E; Meer, D

    2010-01-01

    Treating moving targets using a scanning gantry for proton therapy is a promising but very challenging, not yet clinically demonstrated treatment modality. The interference of organ motion with the sequence of the beam delivery produces uncontrolled dose inhomogeneities within the target. One promising approach to overcome this difficulty is to increase the speed of scanning in order to apply the dose repeatedly (so-called repainting). To obtain sufficiently high scanning speeds a new, technologically improved gantry-Gantry 2-has been designed and is currently under construction at PSI. As there are many possible repainting strategies, the way repainting will be implemented on Gantry 2 will depend on the result of a careful analysis of the various treatment delivery strategies available. To achieve this aim, and prior to the start of experimental work with Gantry 2, simulations of dose distribution errors due to organ motion under various beam delivery strategies were investigated. The effects of motion on the dose distribution were studied for moderate motion amplitudes (5 mm) for spherical target volumes in a homogeneous medium and with homogeneous dose. In total over 200 000 dose distributions have been simulated and analyzed and selected results are discussed. From the obtained results we are confident to be able to treat moderately moving targets on Gantry 2 using repainted pencil-beam spot scanning. Continuous line scanning seems to be the most elegant solution; it provides higher repainting rates and produces superior results but is probably more difficult to realize. For larger motion amplitudes, continuous line scanning still shows good results, but we plan anyways to use a gating system for these cases, not only to reduce the inhomogeneity within the target volume but also to reduce safety margins.

  19. Determinants of Port Performance - Case Study of 4 Main Ports in Indonesia (2005-2015

    Directory of Open Access Journals (Sweden)

    Atika Aqmarina

    2018-03-01

    Full Text Available Port plays significant role in supporting economic growth of a country. This study aims to analyze the determinant of port performance in Indonesia. In this research, the ports selected are four main ports in Indonesia which are Port of Belawan, Port of Tanjung Priok, Port of Tanjung Perak, and Makassar. These ports are designed as the hub ports in the national sea transport system of the country. The study used pooled OLS as the methodology to analyze the determinant. The result of this studies shows that total traffic is not influenced by operating surplus per ton, whereas the rest of variables such as turnaround time, idle time, berth of occupancy rate, rate of return, number of employee and cargo equipment have significant results and significantly influenced the total traffic.

  20. Engineering issues on the diagnostic port integration in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Bertalot, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Cheon, Mun Seong [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Giacomin, Thibaud [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Heemskerk, Cock J.M.; Koning, Jarich F. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Lee, Hyeon Gon [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Nemtcev, Grigorii [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation); Ronden, Dennis M.S. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Seon, Chang Rae [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Udintsev, Victor; Yukhnov, Nikolay [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Zvonkov, Alexander [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation)

    2016-11-01

    Highlights: • Diagnostic port integration in the upper port 18 of ITER is presented in order to house the three diagnostic systems. • Issue on the neutron shielding in the upper port 18 is addressed and the shut-down dose rate in the interspace is summarized. • The maintenance strategy in the upper port 18 is described. - Abstract: The upper port #18 (UP18) in ITER hosts three diagnostic systems: the neutron activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron camera. These diagnostics are integrated into three infrastructures in the port: the upper port plug, interspace support structure and port cell support structure. The port integration in UP18 is at the preliminary design stage and the current design of the infrastructure as well as the diagnostic integration is described here. The engineering issues related to neutron shielding and maintenance are addressed and the design approach is suggested.

  1. Using service-time profiles for distributed planning of container barge rotations along terminals

    NARCIS (Netherlands)

    Douma, A.M.; Schuur, Peter; Schutten, Johannes M.J.

    2008-01-01

    We consider the barge rotation planning and quay scheduling problem in the Port of Rotterdam. This problem concerns the alignment of barge rotations and terminal quay schedules. We use a Multi-Agent based approach for the problem, since such a Multi-Agent based system can mirror to a large extent

  2. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  3. COMPETITION BETWEEN CONTAINER PORTS IN THE NORTHERN ADRIATIC

    OpenAIRE

    Elen Twrdy; Milan Batista

    2014-01-01

    World trade has changed in the last decade such that container traffic flows are oriented towards more parts of the European continent. The European container port system is not a homogeneous set of ports; instead it consists of several big ports (e.g., Rotterdam, Hamburg, Algeciras...) and a large number of medium and small ports. Northern Adriatic (NA) ports, namely Rijeka, Koper, Trieste, Venice and Ravenna, are small ports. Each of these ports have different development plans but in varyi...

  4. The Challenges of Malaysian Dry Ports Development

    Directory of Open Access Journals (Sweden)

    Jagan Jeevan

    2015-03-01

    Full Text Available This paper examines the functions and challenges of dry ports development in Malaysia through 11 face-to-face interviews with dry port stakeholders. The findings reveal that Malaysian dry ports are developed to accelerate national and international business, to activate intermodalism in the nation, to promote regional economic development and to enhance seaport competitiveness. Malaysian dry ports perform the function of transport and logistics, information processing, seaports and value-added services. Challenges facing Malaysian dry ports include insufficient railway tracks, unorganized container planning on the rail deck, highly dependent on single mode of transportation, poor recognition from the seaport community, and competition from localized seaports. This paper further indicates strategies for coping with these challenges and identifies future opportunities for Malaysian dry ports development.

  5. Port pricing : principles, structure and models

    OpenAIRE

    Meersman, Hilde; Strandenes, Siri Pettersen; Van de Voorde, Eddy

    2014-01-01

    Price level and price transparency are input to shippers’ choice of supply chain and transport mode. In this paper, we analyse current port pricing structures in the light of the pricing literature and consider opportunities for improvement. We present a detailed overview of pricing criteria, who sets prices and who ultimately foots the bill for port-of-call charges, cargo-handling fees and congestion charges. Current port pricing practice is based on a rather linear structure and fails to in...

  6. Efficiency analysis of container ports and terminals

    OpenAIRE

    Liu, Q.

    2010-01-01

    In the past two decades the steady growth of seaborne trade has resulted in the increase of container ships, container ports and their terminals. The structure of the shipping market is, moreover, continuously evolving. On the carrier side, shipping companies form consortia and alliances; on the port side, global terminal operators and dedicated container terminals are emerging. The aim of this research is to evaluate the efficiency of container ports and terminals and to study...

  7. Port Sunlight, essai architectural et social

    OpenAIRE

    Machet, Laurence

    2017-01-01

    The purpose of this article is to examine the city of Port Sunlight, its history, design and originality. Created by William Lever in 1888 in order to house his newly-built soap factory, Port Sunlight is part of the numerous “factory villages” built in the wake of the industrial revolution according to philanthropic and utilitarian principles. But this article intends to show that Port Sunlight differs from other factory towns. Its careful design, elaborate architecture and public facilities ...

  8. PORT SECURITY-Threats and Vulnerabilities

    OpenAIRE

    Kusi, Bernard

    2015-01-01

    The main objective of this thesis is to identify the threats and the vulnerabilities concerning Takoradi port, and finally recommend measure to overcome the identified threats and vul-nerabilities. Various categories of potential threats and vulnerabilities have been studied throughout the literature review. However, because each port presents a unique sets of threats and vulnerabilities, there was a need to look critically into how Takoradi port operations are being conducted in other to ide...

  9. Maximizing port and transportation system productivity by exploring alternative port operation strategies.

    Science.gov (United States)

    2011-06-01

    Seaports are a critical transportation component that supports the nations economy. Many U.S. : ports are now experiencing significant truck congestion at the gate, which decreases the productivity of : ports and truck fleets (e.g. truck wait time...

  10. US Army Corps of Engineers Ports, Geographic WGS84, BTS (2006) [usace_port_BTS_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — Contains physical information on commercial facilities at the principal U.S. Coastal, Great Lakes and Inland Ports. The data consists of listings of port area's...

  11. THE Port - hackathon at CERN

    CERN Multimedia

    CERN. Geneva; KNAEPPER, Ines; SILVA DE SOUSA, Bruno

    2014-01-01

    THE Port association combines creative minds from CERN and non-profit organisations in interdisciplinary teams to work on humanitarian technology related benefits to society. Our interdisciplinary teams of handpicked individuals chosen for their field-leading expertise and innovative mind combine humanitarian questions with state of the art science, cutting-edge technology and endless fantasy. We aim to impact the future by fusion of today’s real life problems analysis and vision of scientific evolution of the next decades. This forces us to develop concepts and solutions for the future - hungry to use our expertise in challenges of new fields.

  12. Port virtual addressing for PC

    International Nuclear Information System (INIS)

    Bolanos, L.; Arista, E.; Osorio Deliz, J.F.

    1997-01-01

    Instruments for nuclear signal measurements based on add-on card for a personal computer (PC) are designed often. Then one faces the problem of the addressing of data input/output devices which show an integration level or intelligence that makes the use of several port address indispensable, and these are limited in the PC. The virtual addressing offers the advantage of the occupation of few addresses to accede to many of these devices. The principles of this technique and the appliances of a solution in radiometric in a radiometric card based on programmed logic are discussed in this paper

  13. POLICY PORT IN LATIN AMERICA

    Directory of Open Access Journals (Sweden)

    María Victoria Flores

    2012-07-01

    Full Text Available This work achieves a contextual approach the port services market in Latin America, from the document review the legal framework and jurisprudence. It observes and evaluates the phenomenon under study, establishing a correlation between the grant in the shape of the free supply and demand for services and operating in a market of few suppliers, resulting in national legislation and concession contracts defending a free market and on the other hand, case law on market practice indicating that there is no free market to defend.

  14. Influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in Monaco planning system: A planning study

    Directory of Open Access Journals (Sweden)

    L Nithya

    2014-01-01

    Full Text Available The objective of this study was to analyze the influence of the increment of gantry angle and the number of arcs on esophageal volumetric modulated arc therapy plan. All plans were done in Monaco planning system for Elekta Synergy linear accelerator with 80 multileaf collimator (MLC. Volumetric modulated arc therapy (VMAT plans were done with different increment of gantry angle like 15 o , 20 o , 30 o and 40 o . The remaining parameters were similar for all the plans. The results were compared. To compare the plan quality with number of arcs, VMAT plans were done with single and dual arc with increment of gantry angle of 20 o . The dose to gross tumor volume (GTV for 60 Gy and planning target volume (PTV for 48 Gy was compared. The dosimetric parameters D 98% , D 95% , D 50% and D max of GTV were analyzed. The homogeneity index (HI and conformity index (CI of GTV were studied and the dose to 98% and 95% of PTV was analyzed. Maximum dose to spinal cord and planning risk volume of cord (PRV cord was compared. The Volume of lung receiving 10 Gy, 20 Gy and mean dose was analyzed. The volume of heart receiving 30 Gy and 45 Gy was compared. The volume of normal tissue receiving greater than 2 Gy and 5 Gy was compared. The number of monitor units (MU required to deliver the plans were compared. The plan with larger increment of gantry angle proved to be superior to smaller increment of gantry angle plans in terms of dose coverage, HI, CI and normal tissue sparing. The number of arcs did not make any difference in the quality of the plan.

  15. Testing and Analysis of Sensor Ports

    Science.gov (United States)

    Zhang, M.; Frendi, A.; Thompson, W.; Casiano, M. J.

    2016-01-01

    This Technical Publication summarizes the work focused on the testing and analysis of sensor ports. The tasks under this contract were divided into three areas: (1) Development of an Analytical Model, (2) Conducting a Set of Experiments, and (3) Obtaining Computational Solutions. Results from the experiment using both short and long sensor ports were obtained using harmonic, random, and frequency sweep plane acoustic waves. An amplification factor of the pressure signal between the port inlet and the back of the port is obtained and compared to models. Comparisons of model and experimental results showed very good agreement.

  16. DEA Window Analysis for Measuring Port Efficiencies in Serbia

    Directory of Open Access Journals (Sweden)

    Danijela Pjevčević

    2012-01-01

    Full Text Available The aim of the paper is to apply Data Envelopment Analysis (DEA method in measuring and analyzing the efficiencies of ports on the river Danube. DEA window analysis is used to determine the efficiency of ports and to observe the possibility of changes in the port efficiency over time. A study is conducted to evaluate the efficiencies of ports on the territory of Serbia in order to identify the sources of inefficiencies and formulate proposals for improving the services of those ports and their operations through a four-year window analysis with port efficiency trends and average efficiencies. The progress is made in the measurement of port efficiency in relation to port productive activities - total area of warehouses, quay length, number of cranes and port throughput, for the Serbian river ports. Keywords: river ports, total area of warehouses, quay length, number of cranes, port throughput, port efficiency, DEA window analysis

  17. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    Directory of Open Access Journals (Sweden)

    Eka Wahyudi

    2012-05-01

    Full Text Available Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC. Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer. Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port paralel lebih banyak dipergunakan untuk pengendalian nyala lampu (LED. Dengan memanfaatkan bantuan software Saraf Listrik versi 1.01, maka port paralel dapat menjadi alternatif baru untuk pengendalian traffic light.

  18. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    OpenAIRE

    Soner Esmer; Hong-Oanh Nguyen, Ph.D.; Yapa Mahinda Bandara, Ph.D.; Kazim Yeni, Ph.D.

    2016-01-01

    Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector...

  19. 19 CFR 101.3 - Customs service ports and ports of entry.

    Science.gov (United States)

    2010-04-01

    ... and Service Ports. Many of the ports listed were created by the President's message of March 3, 1913....S.C. 1). Subsequent orders of the President or of the Secretary of the Treasury which affected these... Port of the Delaware River and Bay described in T.D. 96-4. Perth Amboy New Mexico Albuquerque Including...

  20. Rotator cuff exercises

    Science.gov (United States)

    ... 25560729 . Read More Frozen shoulder Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT scan Shoulder MRI scan Shoulder pain Patient Instructions Rotator cuff - self-care Shoulder surgery - discharge Using your ...

  1. The radiation analyses of ITER lower ports

    International Nuclear Information System (INIS)

    Petrizzi, L.; Brolatti, G.; Martin, A.; Loughlin, M.; Moro, F.; Villari, R.

    2010-01-01

    The ITER Vacuum Vessel has upper, equatorial, and lower ports used for equipment installation, diagnostics, heating and current drive systems, cryo-vacuum pumping, and access inside the vessel for maintenance. At the level of the divertor, the nine lower ports for remote handling, cryo-vacuum pumping and diagnostic are inclined downwards and toroidally located each every 40 o . The cryopump port has additionally a branch to allocate a second cryopump. The ports, as openings in the Vacuum Vessel, permit radiation streaming out of the vessel which affects the heating in the components in the outer regions of the machine inside and outside the ports. Safety concerns are also raised with respect to the dose after shutdown at the cryostat behind the ports: in such zones the radiation dose level must be kept below the regulatory limit to allow personnel access for maintenance purposes. Neutronic analyses have been required to qualify the ITER project related to the lower ports. A 3-D model was used to take into account full details of the ports and the lower machine surroundings. MCNP version 5 1.40 has been used with the FENDL 2.1 nuclear data library. The ITER 40 o model distributed by the ITER Organization was developed in the lower part to include the relevant details. The results of a first analysis, focused on cryopump system only, were recently published. In this paper more complete data on the cryopump port and analysis for the remote handling port and the diagnostic rack are presented; the results of both analyses give a complete map of the radiation loads in the outer divertor ports. Nuclear heating, dpa, tritium production, and dose rates after shutdown are provided and the implications for the design are discussed.

  2. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Opp, Daniel; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir, E-mail: vladimir.feygelman@moffitt.org [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2014-06-15

    Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period

  3. Port-Orford-Cedar Root Disease

    Science.gov (United States)

    Lewis F. Roth; Robert D. Jr. Harvey; John T. Kliejunas

    1987-01-01

    The most serious disease of Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murr.) Parl.) is a root disease caused by the fungus Phytophthora lateralis. Nursery stock, ornamentals, and timber trees are subject to attack. Other species of Chamaecyparis are less susceptible than Port-Orford-cedar, and trees of other genera are not affected.

  4. Are we connected? : Ports in Global Networks

    NARCIS (Netherlands)

    R.A. Zuidwijk (Rob)

    2015-01-01

    markdownabstractAbstract Global supply chains are built on organizational, information, and logistics networks. Ports are connected via these networks and also need to connect these networks. Synchromodality is an innovative concept for container transportation, and the port plays an important

  5. Lessons from Hurricane Sandy for port resilience.

    Science.gov (United States)

    2013-12-01

    New York Harbor was directly in the path of the most damaging part of Hurricane Sandy causing significant impact on many of the : facilities of the Port of New York and New Jersey. The U.S. Coast Guard closed the entire Port to all traffic before the...

  6. Visual Support for Porting Large Code Bases

    NARCIS (Netherlands)

    Broeksema, Bertjan; Telea, Alexandru

    2011-01-01

    We present a tool that helps C/C++ developers to estimate the effort and automate software porting. Our tool supports project leaders in planning a porting project by showing where a project must be changed, how many changes are needed, what kinds of changes are needed, and how these interact with

  7. Single port VATS: recent developments in Asia.

    Science.gov (United States)

    Yu, Peter S Y; Capili, Freddie; Ng, Calvin S H

    2016-03-01

    Single port video-assisted thoracic surgery (VATS) is the most recent evolution in minimally invasive thoracic surgery. With increasing global popularity, the single port VATS approach has been adopted by experienced thoracic surgeons in many Asian countries. From initial experience of single port VATS lobectomy to the more complex sleeve resection procedures now forming part of daily practice in some Asia institutes, the region has been the proving ground for single port VATS approaches' feasibility and safety. In addition, certain technical refinements in single port VATS lung resection and lymph node dissection have also sprung from Asia. Novel equipment designed to facilitate single port VATS allowing further reduce access trauma are being realized by the partnership between surgeons and the industries. Advanced thoracoscopes and staplers that are narrower and more maneuverable are particularly important in the smaller habitus of patients from Asia. These and similar new generation equipment are being applied to single port VATS in novel ways. As dedicated thoracic surgeons in the region continue to striving for excellence, innovative ideas in single incision access including subxiphoid and embryonic natural-orifice transluminal endoscopic surgery (e-NOTES) have been explored. Adjunct techniques and technology used in association with single port VATS such as non-intubated surgery, hybrid operating room image guidance and electromagnetic navigational bronchoscopy are all in rapid development in Asia.

  8. Cyber security in ports : Business as usual

    NARCIS (Netherlands)

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the

  9. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  10. Rotterdam as a World Port City

    NARCIS (Netherlands)

    Wouter Jacobs; Menno Huijs; Isabelle Vries

    2015-01-01

    Most studies and models on the port-city interface focus on the inevitable process in which ports and cities grow apart, both spatially and economically. What is often overlooked is the relationships that remain in the form of maritime business services (finance, insurance, legal). These maritime

  11. Working with Nature in Wadden Sea Ports

    NARCIS (Netherlands)

    Baptist, M.J.; Eekelen, van E.; Dankers, P.J.T.; Grasmeijer, B.; Kessel, van T.; Maren, van D.S.

    2017-01-01

    Wadden Sea ports are situated at the border of the UNESCO World Heritage site Wadden Sea. Because of the protected status of this area, developing new economic activities is not straightforward. However, maintaining and developing port activities is needed to safeguard the economic viability of the

  12. Dry Port Development: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Studies on dry ports as nodes in multimodal transport have been expanded to decrease the mounting congestion on seaports. The principal objective of this study is to inspect how dry port researches have been conducted from different perspective. This paper tries to recap the existing researches that aimed to study dry port concept via a systematic review, to present a general overview of the researches on our relevant region and propose a classification for these researches. This paper present a systematic review of dry port that looks to illustrate the progress of researches on this area between 1986 and 2015, collecting researches on dry port concept and analyzing the main characteristics of the dry port development and their contribution to the multimodal transport. The results indicated that most dry port studies considerate the strategic level and concentrate in the Asian continent. Studies regarding other decision levels and continents have to be developed in further researches. Although the existing studies make a contribution in dry port concept, they allow gaps in terms of operational and tactical decision levels considering their limited geographical region.

  13. Laser treatment of Port-wine stains

    OpenAIRE

    Boffa, Michael J.

    2001-01-01

    A state-of-the-art pulsed dye laser machine to treat port-wine stains and other vascular lesions has been available in the Malta Health Service since 1999. This article reviews the pathophysiology and clinical features of port- wine stains and describes the principles of laser treatment for this condition.

  14. Ports Primer: 3.3 Federal and International Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  15. Two-port access versus four-port access laparoscopic ovarian cystectomy.

    Science.gov (United States)

    Choi, Won-Kyu; Kim, Jang-Kew; Yang, Jung-Bo; Ko, Young-Bok; Nam, Sang-Lyun; Lee, Ki-Hwan

    2014-09-01

    This study was conducted to compare the surgical outcomes between two-port access and four-port access laparoscopic ovarian cystectomy. Four hundred and eighty nine patients who had received two-port access laparoscopic ovarian cystectomy (n=175) and four-port access laparoscopic ovarian cystectomy (n=314) in Chungnam National University Hospital from January 2009 to August 2012 were analyzed retrospectively. The data were compared between the bilaterality of the cysts and cyst diameter of less than 6 cm and 6 cm or more. There were no significant differences in patient's age, parity, body weight, body mass index and history of previous surgery between the two-port and four-port access laparoscopy group. Bilaterality of ovarian cysts was more in fourport access laparoscopy group (13.7% vs. 32.5%, P=0.000). There were no significant differences in operation time, hemoglobin change, hospital stay, adhesiolysis, transfusion, and insertion of hemo-vac between the two-port and four-port access laparoscopy group for size matched compare. However additional analgesics were more in four-port access laparoscopy group for unilateral ovarian cystectomy. Two-port access laparoscopic surgery was feasible and safe for unilateral and bilateral ovarian cystectomy compare with four-port access laparoscopic surgery.

  16. Influence of Port Policy on the Development of Croatian Container Ports

    Directory of Open Access Journals (Sweden)

    Čedomir Dundović

    2002-03-01

    Full Text Available It is important to consider the port development throughoutthe world from the aspect of economical, transport and portpolicy and their mutual impact on commerce and efficiency ofports. By examining such relations in the context of developmentof the Croatian container ports, it is possible to define reasonsfor lagging behind of Croatian ports compared to theworld movements.The main reason for the negative trend of development ofCroatian container ports lies in the non-existence of adequatemeasures of transport, maritime and port policy. Analysis ofstatistics over the past decade and comparison of structure andvolume of the general cargo traffic in the Rijeka port and theneighbouring ports in the area of North Adriatic are both showingsignificant size discrepancy and uncompetitiveness of theCroatian port. Disturbances that have brought to such a situationresult from inadequate port policy and non-harmonisedactivities between various modes of transport.In order to overcome such situation, the authors suggest determiningof clear tasks, goals and measures of the port policythat have to be undertaken so that the Croatian policy could becompatible with the main aspects, development tendencies andmeasures of theE U port policy.

  17. Colonial Origins of the Port of Buenaventura

    Directory of Open Access Journals (Sweden)

    Alonso Valencia Llano

    2014-07-01

    Full Text Available This article studies the origins of the Port of Buenaventura in the New Kingdom of Granada. It begins with the process of exploration of the coastal territory in order to highlight the different sites in which it was situated, demonstrating that it began as a river port and was later resituated and gradually converted into a maritime port. In addition, this article analyzes the problems it faced, such as the dificulty of communication with the interior of the country, the indigenous resistance that caused the destruction of the town, and inally the necessity of populating the zone with black slaves in order to exploit the mining border. This study also discusses how this port was controlled by the elite of the city of Cali, until the Republican period when it became the sole Colombian port on the Paciic Ocean.

  18. Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Susu, E-mail: syan5@mgh.harvard.edu; Lu, Hsiao-Ming; Flanz, Jay; Adams, Judith; Trofimov, Alexei; Bortfeld, Thomas

    2016-05-01

    Purpose: To retrospectively analyze the beam approaches used in gantry-based proton treatments, and to reassess the practical advantages of the gantry, compared with beam approaches that are achievable without a gantry, in the context of present-day technology. Methods and Materials: We reviewed the proton therapy plans of 4332 patients treated on gantries at our hospital, delivered by the double scattering technique (n=4228) and, more recently, pencil beam scanning (PBS) (n=104). Beam approaches, relative to the patient frame, were analyzed individually to identify cases that could be treated without a gantry. Three treatment configurations were considered, with the patient in lying position, sitting position, or both. The FIXED geometry includes a fixed horizontal portal. The BEND geometry enables a limited vertical inflection of the beam by up to 20°. The MOVE geometry allows for flexibility of the patient head and body setup. Results: The percentage of patients with head and neck tumors that could be treated without a gantry using double scattering was 44% in FIXED, 70% in 20° BEND, and 100% in 90° MOVE. For torso regions, 99% of patients could be treated in 20° BEND. Of 104 PBS treatments, all but 1 could be reproduced with FIXED geometry. The only exception would require a 10° BEND capability. Note here that the PBS treatments were applied to select anatomic sites, including only 2 patients with skull-base tumors. Conclusions: The majority of practical beam approaches can be realized with gantry-less delivery, aided by limited beam bending and patient movements. Practical limitations of the MOVE geometry, and treatments requiring a combination of lying and sitting positions, may lower the percentage of head and neck patients who could be treated without a gantry. Further investigation into planning, immobilization, and imaging is needed to remove the practical limitations and to facilitate proton treatment without a gantry.

  19. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  20. Dual-port distal gastrectomy for the early gastric cancer

    OpenAIRE

    Kashiwagi, Hiroyuki; Kumagai, Kenta; Monma, Eiji; Nozue, Mutsumi

    2014-01-01

    Background Although recent trends in laparoscopic procedures have been toward minimizing the number of incisions, four or five ports are normally required to complete laparoscopic gastrectomy because of the complexity of this procedure. Multi-channel ports, such as the SILS port (Covidien, JAPAN), are now available and are crucial for performing single-incision laparoscopic surgery (SILS) or reduced port surgery (RPS). We carried out reduced port distal gastrectomy (RPDG) using a dual-port me...

  1. E-Commerce in Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2002-01-01

    Full Text Available EDI (Electronic Data Interchange and electronic businessshould be looked upon as a natural evolution in the internationaltrade and transport cycle. One of the principal reasonsfor starting to use EDI are the heaps of documents written,shifted, handled, conected, transcribed and copied for normalbusiness and administrative transactions. EDJ and in generalelectronic business would have none of the disadvantages ofpaper documents and have already brought substantial benefitsand savings to companies that implement it.Most port community systems today still do not provide forelectronic transfer of funds or for electronic interchange of invoicesand other trade documents, for instance bills of lading.Such services are specific toe-business and they are the necessarytransport-related documents.

  2. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

    Science.gov (United States)

    Yıldırım, İlknur; Tütüncü, Ayşe Çiğdem; Bademler, Süleyman; Özgür, İlker; Demiray, Mukaddes; Karanlık, Hasan

    2018-03-01

    To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications. The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

  3. The Practice of Guangzhou Port Planning Environmental Impact Assessment

    Science.gov (United States)

    Wang, Ning; Zhao, Junjie; Shou, Youping; Qiao, Jianzhe; Dong, Shipei; Zhang, Lu

    2018-01-01

    In this paper, the effects of the implementation of Guangzhou port plan were analyzed from hydrological condition, water environment and ecological environment. Regional water environmental carrying capacity was analyzed. Guangzhou port is a main port in the coast of China, it is an important port of foreign trade in south China, it is an important port for energy supplies and raw materials in Guangdong province [1]. With the shipping channel condition improvement and the construction of large specialized container port area, Guangzhou port will gradually become trunk line port of container transport in south China.

  4. Dosimetric comparison of RapidArc with fixed gantry dynamic IMRT for loco-regionally advanced nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wu Hao; Han Shukui; Sun Yan; Jiang Fan

    2010-01-01

    Objective: To compare the dosimetric difference of RapidArc and fixed gantry angle dynamic IMRT (dIMRT) for loco-regionally advanced nasopharyngeal carcinoma. Methods: Ten previously treated patients with loco-regionally advanced nasopharyngeal carcinoma were replanned with RapidArc and dIMRT, respectively. The prescription dose was GTV 70 Gy/33 f and PTV 60 Gy/33 f. All plans met the requirement: 95% of PTV was covered by 60 Gy. Dose-volume histogram data, isodose distribution, monitor units, and treatment time were compared. Results: Dose distribution has no significant difference between the two techniques. RapidArc reduced the dose of the brainstem, mandible, and other normal tissues compared with dIMRT. Mean monitor units were 589.5 and 1381.0 for RapidArc and dIMRT (reduced by 57% relatively). Mean treatment time was 2.33 min and 7.82 min for RapidArc and dIMRT (reduced by 70% relatively). Conclusions: Compared with dIMRT, RapidArc achieves equal target coverage and OAR sparing while using fewer monitor units and less time during radiotherapy for patient with loco-regionally advanced nasopharyngeal carcinoma. (authors)

  5. Dosimetric comparison between RapidArc and fixed gantry intensity modulated radiation therapy in treatment of liver carcinoma

    International Nuclear Information System (INIS)

    Ma Changsheng; Yin Yong; Liu Tonghai; Chen Jinhu; Sun Tao; Lin Xiutong

    2010-01-01

    Objective: To compare the dosimetric difference of RapidArc and fixed gantry IMRT for liver carcinoma. Methods: The CT data of 10 liver cancer patients were used to design 3 groups of treatment plan: IMRT plan, single arc RapidArc plan (RA1), and dual arc RapidArc plan (RA2). The planning target volume (PTV) dosimetric distribution, the organs at risk (OAR) dose, the normal tissue dose, mornitor units (MU) and treatment time were compared. Results: The maximum dose of PTV in RA1 and RA2 plans were lower than that of IMRT (Z=-2.0990, -2.666, P 40 of stomach small bowel than IMRT plan, but higher in mean dose of left kidney (Z=-1.988, -2.191, P 5 , V 10 and 15 of healthy tissue in RapidArc plan groups were higher than those in IMRT plan, while the values of V 20 , V 25 and V 30 of healthy tissue in RapidArc plan groups were than those in IMRT plan. The number of computed MU/fraction of Rapid Arc plan was 40% or 46% of IMRT plan and the treatment time was 30% and 40% of IMRT. Conclusions: RapidArc showed improvements in conformity index and healthy tissue sparing with uncompromised target coverage. RapidArc could lead to the less MU and shorter delivery time compared to IMRT. (authors)

  6. Rotational motion in nuclei

    International Nuclear Information System (INIS)

    Bohr, A.

    1977-01-01

    History is surveyed of the development of the theory of rotational states in nuclei. The situation in the 40's when ideas formed of the collective states of a nucleus is evoked. The general rotation theory and the relation between the single-particle and rotational motion are briefly discussed. Future prospects of the rotation theory development are indicated. (I.W.)

  7. Šport in humanistika

    Directory of Open Access Journals (Sweden)

    Jože Vogrinc

    2012-07-01

    Full Text Available O tem, ali je šport »neresen« pojav ali pojav, ki razkriva bistvene razsežnosti tistega, za kar človeku gre, se pogledi razhajajo. Glede na to, da so humanistične študije športa vsaj na prvi pogled nekje na obrobju ved, ki jih združuje Filozofska fakulteta, bi morda veljalo, da ga ne moremo primerjati z globoko resnimi temami, zlasti pa ne z najnovejšimi resnimi zahtevami, ki jih družba postavlja univerzi in znanostim: pripomoči k višji donosnosti in poslovnosti podjetništva ter ohranjati tradicijo in krepiti življenjsko moč naroda. Pa se že pri tem izkaže, da športa ne gre preveč zapostavljati; po eni strani je že nekaj desetletij, kar je postal izjemno kapitalsko zanimivo in donosno področje, v katero podjetniki bodisi vlagajo, da bi dosegali dobičke, bodisi ga podpirajo, da bi z njegovo pomočjo svoje blago povzdignili v simbol pravilno naravnanega načina življenja; po drugi strani pa je tradicija nacionalne pomembnosti vrhunskih športnih izidov in dosežkov le nekaj krajša od drugih načinov mednarodnega uveljavljanja naroda, pomen športnih dosežkov za dokazovanje življenjske moči naroda pa se lahko kosa s pomenom lestvic, kakršne izdajajo mednarodne finančne ustanove o državah, ali lestvic, na katerih najdemo univerze, razvrščene po njihovi pedagoški in znanstveni moči. Pomembnost športa pa podčrtavajo tudi tisti, ki ga ostro kritizirajo in njegovo sodobno vrhunsko različico odklanjajo kot obliko alienacije, manipulacije in ideologije, saj prav športni spektakularizaciji pripisujejo najvišjo napetost, največji pomen in najotipljivejšo moč nad ljudmi, ki bi se morali bojevati za spremembo svojega družbenega položaja in prevrat v vsej družbeni strukturi, pa jih razvedrila, med katerimi ima šport posebej visoko mesto, uspavajo in pomirjajo prav s tem, da njihovo napetost sproščajo v nenevaren odliv socialne energije. Tega kritičnega vidika sodobnega športa ne kaže omejiti zgolj na vrhunski

  8. Monte Carlo investigation of collapsed versus rotated IMRT plan verification.

    Science.gov (United States)

    Conneely, Elaine; Alexander, Andrew; Ruo, Russell; Chung, Eunah; Seuntjens, Jan; Foley, Mark J

    2014-05-08

    IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at the planned gantry angle (rotated delivery). We examined, established, and optimized Monte Carlo simulations of the dosimetry for IMRT verification of treatment plans for these two different delivery modes (collapsed versus rotated). The results of the simulations were compared to the treatment planning system dose calculations for the two delivery modes, as well as to measurements taken. This was done in order to investigate the validity of the use of a collapsed delivery technique for IMRT QA. The BEAMnrc, DOSXYZnrc, and egs_chamber codes were utilized for the Monte Carlo simulations along with the MMCTP system. A number of different plan complexity metrics were also used in the analysis of the dose distributions in a bid to qualify why verification in a collapsed delivery may or may not be optimal for IMRT QA. Following the Alfonso et al. formalism, the kfclin,frefQclin,Q correction factor was calculated to correct the deviation of small fields from the reference conditions used for beam calibration. We report on the results obtained for a cohort of 20 patients. The plan complexity was investigated for each plan using the complexity metrics of homogeneity index, conformity index, modulation complexity score, and the fraction of beams from a particular plan that intersect the chamber when performing the QA. Rotated QA gives more consistent results than the collapsed QA technique. The kfclin,frefQclin,Qfactor deviates less from 1 for rotated QA than for collapsed QA. If the homogeneity index is less than 0.05 then the kfclin,frefQclin,Q factor does not deviate from unity by more than 1%. A value this low for the homogeneity index can only be obtained

  9. Rotational motion in nuclei

    International Nuclear Information System (INIS)

    Bohr, A.

    1976-01-01

    Nuclear structure theories are reviewed concerned with nuclei rotational motion. The development of the deformed nucleus model facilitated a discovery of rotational spectra of nuclei. Comprehensive verification of the rotational scheme and a successful classification of corresponding spectra stimulated investigations of the rotational movement dynamics. Values of nuclear moments of inertia proved to fall between two marginal values corresponding to rotation of a solid and hydrodynamic pattern of an unrotating flow, respectively. The discovery of governing role of the deformation and a degree of a symmetry violence for determining rotational degrees of freedon is pointed out to pave the way for generalization of the rotational spectra

  10. TRENDS IN CONTEMPORARY PORT SERVICES MARKETS

    Directory of Open Access Journals (Sweden)

    Hanna Klimek

    2014-12-01

    Full Text Available This article describes the issues associated with functioning of contemporary seaport services markets. The growth of international supply chains, technical progress and the integration processes in shipping, growth of containerization, increasing competition in the seaport services markets and environmental protection regulations make it necessary for port service providers to adapt to the changing expectations and requirements of their customers, both shippers and, especially maritime, carriers. Thus, the activities they undertake are associated with making investments to ensure an adequate capacity to handle cargo, passengers and means of transport, required quality of service, but also with appropriate organization of port supply centres and lead to an improvement of their competitiveness. Both the factors associated with the external and internal environment of seaports affect the changes in the relationship between the supply and demand on port services markets. Contemporary port services markets are characterized by certain phenomena which can be a sign of their adaptation and development. The aim of this article is to present the essence of the port services market and its relationship with the environment, which subject to rapid and significant changes, creates new conditions for the operation of port supply centres and the entire port services market.

  11. Towards Sustainable ASEAN Port Development: Challenges and Opportunities for Vietnamese Ports

    Directory of Open Access Journals (Sweden)

    Saeyeon Roh

    2016-06-01

    Full Text Available Sustainability agendas are challenging port authorities around the world to find ways of operating and managing their ports efficiently and effectively in terms of economic, social, as well as environmental development. In this respect, governments in ASEAN countries have been implementing various green activities seeking to reduce the environmental impact of shipping and related activities. In this connection, most studies in the existing literature mainly focus on the environmental aspects of sustainable development and have not clearly explained what sustainable port development exactly entails. Furthermore, most of these studies emphasized on the impact of port development and overlooked what factors influence sustainable port development. To address these gaps, this research aim to explore the main factors shaping sustainable port development. This was conducted through a comprehensive review of related literature as well as confirmatory in-depth interviews with port authorities. As a result, findings from this research would help identify key elements of sustainable port development from port authorities’ perspective. The challenges, opportunities and managerial implications for Vietnamese ports are also discussed accordingly.

  12. New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

    Energy Technology Data Exchange (ETDEWEB)

    Shandiz, Mahdi Heravian; Khalilzadeh, Mohammadmahdi; Anvari, Kazem [Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Layen, Ghorban Safaeian [Mashhad University of Medical Science, Mashhad (Iran, Islamic Republic of)

    2015-03-15

    In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of 0.43 degrees. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

  13. New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

    International Nuclear Information System (INIS)

    Shandiz, Mahdi Heravian; Khalilzadeh, Mohammadmahdi; Anvari, Kazem; Layen, Ghorban Safaeian

    2015-01-01

    In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of 0.43 degrees. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

  14. Enabling information sharing in a port

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Hvolby, Hans-Henrik; Dukovska-Popovska, Iskra

    2012-01-01

    Ports are integral parts of many supply chains and are as such a contributing factor to the overall efficiency of the supply chain. Ports are also dynamic entities where things changes continuously. The dynamic nature of ports is also a problem when trying to optimise the utilisation of resources...... and ensure a low lead-time. Information sharing is a very important tool to reduce the effect of dynamism. This paper attempts to explain how information sharing is enabled in such an environment, and which considerations are relevant, both in regards to the information and required technology. The paper...

  15. Highest performance in 3D metal cutting at smallest footprint: benchmark of a robot based system vs. parameters of gantry systems

    Science.gov (United States)

    Scheller, Torsten; Bastick, André; Michel-Triller, Robert; Manzella, Christon

    2014-02-01

    In the automotive industry as well as in other industries ecological aspects regarding energy savings are driving new technologies and materials, e.g. lightweight materials as aluminium or press hardened steels. Processing such parts especially complex 3D shaped parts laser manufacturing has become the key process offering highest efficiency. The most established systems for 3D cutting applications are based on gantry systems. The disadvantage of those systems is their huge footprint to realize the required stability and work envelope. Alternatively a robot based system might be of advantage if accuracy, speed and overall performance would be capable processing automotive parts. With the BIM "beam in motion" system, JENOPTIK Automatisierungstechnik GmbH has developed a modular robot based laser processing machine, which meets all OEM specs processing press hardened steel parts. A benchmark of the BIM versus a gantry system was done regarding all required parameters to fulfil OEM specifications for press hardened steel parts. As a result a highly productive, accurate and efficient system can be described based on one or multiple robot modules working simultaneously together. The paper presents the improvements on the robot machine concept BIM addressed in 2012 [1] leading to an industrial proven system approach for the automotive industry. It further compares the performance and the parameters for 3D cutting applications of the BIM system versus a gantry system by samples of applied parts. Finally an overview of suitable applications for processing complex 3D parts with high productivity at small footprint is given.

  16. Assesment of port governance in Brazil: a managerial perspective on the port of Santos

    OpenAIRE

    Almeida, José Eduardo Costa de

    2015-01-01

    The role of maritime transportation within international trade was drastically revamped during the inception of the globalization process, which enhanced the contribution of ports in world economy as main logistics gateways for global production and trade. As a result, the relationship between ports and governments has changed. Devolution ideologies that had been applied in other industries decades ago were now being considered by governments for the port industry. Many central governments so...

  17. Algorithms for Port-of-Entry Inspection

    National Research Council Canada - National Science Library

    Roberts, Fred S

    2007-01-01

    .... The percentage at some ports has now risen to 6%, but this is still a very small percentage. The purpose of this project was to develop decision support algorithms that help to optimally intercept illicit materials and weapons...

  18. Port: arstid kasutavad narkootikume / Marina Lohk

    Index Scriptorium Estoniae

    Lohk, Marina

    2015-01-01

    Tallinna ülikooli terviseteaduste ja spordi instituudi direktor ja spordibioloog Kristjan Port mainis ETV saates "Vabariigi kodanikud", et töövõime taastamiseks kasutatakse sageli narkootilisi aineid ning seda teevad ka arstid. Kristjan Porti selgitused

  19. Port Authority of Allegheny County Transit Stops

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — All transit stops within the Port Authority of Allegheny County's service area for the November 20, 2016 - March (TBD) 2017 schedule period.

  20. Grain operator miffed at port administration

    Index Scriptorium Estoniae

    2006-01-01

    Ventspils Grain Terminal saatis president Vaira Vike-Freibergale ja mitmetele ministritele kirja sõnumiga, et Ventspilsi Vabasadama (Ventspils Free Port) administratsiooni tegevus takistab terminali äritegevust

  1. Tamralipti: The ancient port of India

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.; Rao, S.R.

    20', 87 degrees 55') east coast of India. Other ports of Bengal, such as Satgaon and Sonargaon were also having overseas contacts with Ceylone, Java and Sumatra. In this paper, an attempt is made to synthesize archaeological, literary, epigraphic...

  2. Public Port Finance Survey for FY 2006

    Science.gov (United States)

    2008-12-01

    This report is the result of a cooperative effort between the Maritime Administration and : the American Association of Port Authorities (AAPA). It was prepared by the Maritime : Administration, using financial information furnished by AAPA. : This i...

  3. Variable Delay in port-Hamiltonian Telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2006-01-01

    In several applications involving bilateral telemanipulation, master and slave act at different power scales. In this paper a strategy for passively dealing with variable communication delay in scaled port-Hamiltonian based telemanipulation over packet switched networks is proposed.

  4. An Analysis of Port Service Quality and Customer Satisfaction: The Case of Korean Container Ports

    Directory of Open Access Journals (Sweden)

    Gi Tae Yeo

    2015-12-01

    Full Text Available Ports play a critical role in the economy of many countries and regions. Failure or unreliability of port services can significantly influence port customers—shipping lines and cargo owners—and result in their dissatisfaction. However, what constitutes port service quality (PSQ and its influence on the satisfaction of port customers has not been well investigated in the literature. Therefore, this study investigates the concept of PSQ and its influence on customer satisfaction in the case of Korean container ports. Following a literature review, a conceptual model of PSQ and its influence on customer satisfaction is proposed. The model was validated through a survey of 313 members of the Korean Port Logistics Association (KPLA. Partial least squares structural equation modeling (PLS-SEM was conducted to confirm the PSQ dimensions and to examine their relationship with customer satisfaction using SmartPLS 3.2.1 software. PSQ is found to be a five-factor construct, and its management, and image and social responsibility factors have significant positive effects on customer satisfaction. In addition to its academic contribution, this study also contributes to management practices because port managers can use the PSQ scale to measure their customers’ satisfaction and justify investments in the quality management of port services.

  5. Rotationally invariant correlation filtering

    International Nuclear Information System (INIS)

    Schils, G.F.; Sweeney, D.W.

    1985-01-01

    A method is presented for analyzing and designing optical correlation filters that have tailored rotational invariance properties. The concept of a correlation of an image with a rotation of itself is introduced. A unified theory of rotation-invariant filtering is then formulated. The unified approach describes matched filters (with no rotation invariance) and circular-harmonic filters (with full rotation invariance) as special cases. The continuum of intermediate cases is described in terms of a cyclic convolution operation over angle. The angular filtering approach allows an exact choice for the continuous trade-off between loss of the correlation energy (or specificity regarding the image) and the amount of rotational invariance desired

  6. Managing Risks in Dry Port Operations

    OpenAIRE

    Ciortescu Cezar-Gabriel; Pãvãla?cu Narcis Sebastian

    2012-01-01

    The purpose of this paper is to have an in-depth look into the phenomenon of risk assessment and risk management strategies in managing dry port operations as an integrated part into international containerized freight trade. The fact that world crises take the form of disruptions, bankruptcies, breakdowns, macroeconomic and political changes, and disasters leads to higher risks and makes risk management more and more difficult. This paper aims to discuss the theory behind the dry port concep...

  7. A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

    International Nuclear Information System (INIS)

    Liu Wu; Luxton, Gary; Xing Lei

    2010-01-01

    Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

  8. Diagnostic accuracy of state-of-the-art MDCT scanners without gantry tilt in patients with oral and oropharyngeal cancer

    International Nuclear Information System (INIS)

    Bannas, Peter; Habermann, Christian R.; Jung, Caroline; Bley, Thorsten A.; Ittrich, Harald; Adam, Gerhard; Koops, Andreas

    2012-01-01

    Purpose: Current CT-protocols for staging oral and oropharyngeal cancer include primary transversal slices and secondary tilted slices to avoid artifact-producing regions of dental metalwork. Some of the latest MDCT scanners do not allow gantry tilt. Hence, we assessed the relevance of secondary tilted slices in tumor staging. Materials and methods: Scans of a tiltable 64-row MDCT-scanner of 82 patients with oral or oropharyngeal cancer were retrospectively and independently evaluated twice by three readers: once using the primary transversal scans only, and once taking the transversal and secondary tilted scans into account. Tumor diameters and TN-stage were determined with both methods. Artifacts on transversal scans were analyzed using a 3-point-ranking-scale. Results: Image quality was impaired by severe artifacts in 24% of transversal slices of the oral cavity and in 12% of the oropharynx. The three readers detected an average of 57.7 ± 2.1 of 82 tumors (70%) on transversal CT slices. An average of 6.3 ± 0.6 more tumors (8%) were detected when transversal studies were evaluated in conjunction with secondary tilted slices, leading to a significantly (p = 0.0156–0.0313) increased average detection rate of 64.0 ± 2.0 tumors (78%). Moreover, secondary tilted slices led to a correction of underestimated tumor stages in up to six patients (7.3%). Conclusion: Tilted slices that avoid artifact-producing regions of dental metalwork significantly improve the reader's sensitivity and are of incremental value for staging of oral and oropharyngeal cancers.

  9. Vacuum vessel port structures for ITER-FEAT

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th.

    2001-01-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed

  10. Vacuum vessel port structures for ITER-FEAT

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th

    2001-11-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed.

  11. Research for Foreign Advanced Ports for Protection and Development Experience

    Science.gov (United States)

    Zhang, Lu; Tian, Mingjing; Zhao, Junjie; Shou, Youping; Wang, Ning; Qiao, Jianzhe; Li, Guanglou

    2018-04-01

    Into the twenty-first century, the process globalization of economic and trade is getting faster and faster, As of 2014, China's annual port trading amount topped the world, But in the port of environmental protection sustainable development approach with foreign advanced port environmental management concept has a big gap. Combined with the present situation of modern ports in China. Drawing lessons from foreign advanced environmental protection idea of port, in order to promote the protection of port environment in our country. The experience of protection and development of foreign advanced port environment will be discussed and discussed.

  12. Experimental and numerical investigation of the fluid flow in a side-ported rotary engine

    International Nuclear Information System (INIS)

    Fan, Baowei; Pan, Jianfeng; Tang, Aikun; Pan, Zhenhua; Zhu, Yuejin; Xue, Hong

    2015-01-01

    Highlights: • An optical side-ported rotary engine test bed has been set up and tested by PIV. • A three-dimensional dynamic simulation model is established. • Experiment and numerical simulation are combined to study the flow mechanisms. • A counterclockwise flow pattern was found in the combustion chamber in the experiment. • The effect of various parameters on the flow field is studied by numerical simulation. - Abstract: The side-ported rotary engine is a potential alternative to the reciprocating engine because of its favorable performance at low speed. The performance of side-ported rotary engines is strongly influenced by the flow field in the combustion chamber. In this study, an optical side-ported rotary engine test-bed was built and PIV was employed to measure the flow field in the rotor housing central plane. From experiment results, a counterclockwise swirl was detected in the rotor housing central plane. Meanwhile, a three-dimensional dynamic mesh and turbulent flow model was integrated and simulated using the Fluent CFD software. The three-dimensional dynamic simulation model was validated by comparison with experimental results. In addition, the effect of three major parameters on the flow field in the combustion chamber, namely rotating speed, intake pressure and intake angle were numerically investigated. The results show that a swirl forms in the middle and front of the combustion chamber during the intake stroke under low rotating speed. This is in line with the swirl detected in the rotor housing central plane though the PIV experiment at 600 rpm. Furthermore, the flow field, volume coefficient and average turbulence kinetic energy in the combustion chamber were studied in detail by varying rotating speed, intake pressure and intake angle

  13. Occupational hazards to health of port workers.

    Science.gov (United States)

    Wang, Yukun; Zhan, Shuifen; Liu, Yan; Li, Yan

    2017-12-01

    The aim of this article is to reduce the risk of occupational hazards and improve safety conditions by enhancing hazard knowledge and identification as well as improving safety behavior for freight port enterprises. In the article, occupational hazards to health and their prevention measures of freight port enterprises have been summarized through a lot of occupational health evaluation work, experience and understanding. Workers of freight port enterprises confront an equally wide variety of chemical, physical and psychological hazards in production technology, production environment and the course of labor. Such health hazards have been identified, the risks evaluated, the dangers to health notified and effective prevention measures which should be put in place to ensure the health of the port workers summarized. There is still a long way to go for the freight port enterprises to prevent and control the occupational hazards. Except for occupational hazards and their prevention measures, other factors that influence the health of port workers should also be paid attention to, such as age, work history, gender, contraindication and even the occurrence and development rules of occupational hazards in current production conditions.

  14. Classification and prediction of port variables

    Energy Technology Data Exchange (ETDEWEB)

    Molina Serrano, B.

    2016-07-01

    Many variables are included in planning and management of port terminals. They can beeconomic, social, environmental and institutional. Agent needs to know relationshipbetween these variables to modify planning conditions. Use of Bayesian Networks allowsfor classifying, predicting and diagnosing these variables. Bayesian Networks allow forestimating subsequent probability of unknown variables, basing on know variables.In planning level, it means that it is not necessary to know all variables because theirrelationships are known. Agent can know interesting information about how port variablesare connected. It can be interpreted as cause-effect relationship. Bayesian Networks can beused to make optimal decisions by introduction of possible actions and utility of theirresults.In proposed methodology, a data base has been generated with more than 40 port variables.They have been classified in economic, social, environmental and institutional variables, inthe same way that smart port studies in Spanish Port System make. From this data base, anetwork has been generated using a non-cyclic conducted grafo which allows for knowingport variable relationships - parents-children relationships-. Obtained network exhibits thateconomic variables are – in cause-effect terms- cause of rest of variable typologies.Economic variables represent parent role in the most of cases. Moreover, whenenvironmental variables are known, obtained network allows for estimating subsequentprobability of social variables.It has been concluded that Bayesian Networks allow for modeling uncertainty in aprobabilistic way, even when number of variables is high as occurs in planning andmanagement of port terminals. (Author)

  15. A planning and delivery study of a rotational IMRT technique with burst delivery

    International Nuclear Information System (INIS)

    Kainz, Kristofer; Chen, Guang-Pei; Chang, Yu-Wen; Prah, Douglas; Sharon Qi, X.; Shukla, Himanshu P.; Stahl, Johannes; Allen Li, X.

    2011-01-01

    Purpose: A novel rotational IMRT (rIMRT) technique using burst delivery (continuous gantry rotation with beam off during MLC repositioning) is investigated. The authors evaluate the plan quality and delivery efficiency and accuracy of this dynamic technique with a conventional flat 6 MV photon beam. Methods: Burst-delivery rIMRT was implemented in a planning system and delivered with a 160-MLC linac. Ten rIMRT plans were generated for five anonymized patient cases encompassing head and neck, brain, prostate, and prone breast. All plans were analyzed retrospectively and not used for treatment. Among the varied plan parameters were the number of optimization points, number of arcs, gantry speed, and gantry angle range (alpha) over which the beam is turned on at each optimization point. Combined rotational/step-and-shoot rIMRT plans were also created by superimposing multiple-segment static fields at several optimization points. The rIMRT trial plans were compared with each other and with plans generated using helical tomotherapy and VMAT. Burst-mode rotational IMRT plans were delivered and verified using a diode array, ionization chambers, thermoluminescent dosimeters, and film. Results: Burst-mode rIMRT can achieve plan quality comparable to helical tomotherapy, while the former may lead to slightly better OAR sparing for certain cases and the latter generally achieves slightly lower hot spots. Few instances were found in which increasing the number of optimization points above 36, or superimposing step-and-shoot IMRT segments, led to statistically significant improvements in OAR sparing. Using an additional rIMRT partial arc yielded substantial OAR dose improvements for the brain case. Measured doses from the rIMRT plan delivery were within 4% of the plan calculation in low dose gradient regions. Delivery time range was 228-375 s for single-arc rIMRT 200-cGy prescription with a 300 MU/min dose rate, comparable to tomotherapy and VMAT. Conclusions: Rotational IMRT

  16. Inland Ports in the Republic of Croatia: Approvals for Port Activities instead of Concessions

    Directory of Open Access Journals (Sweden)

    Goran Vojković

    2008-11-01

    Full Text Available According to the 1998 Act on Inland Ports, the right to performall port activities within inland ports of the Republic ofCroatia is given on the basis of concession, obtained throughbidding. It has been noticed in practice that modem businessprocesses and traffic flows are more dynamic than before whenclassic concession relations were created. Also, types andamounts of cargo are changing every couple of years, which isfollowed by quick adjustments, instead of working according torigid and long-term defined decisions and concession contracts.Furthermore, the practice has shown for some activitiesthat the number of port providers (such as ship suppliers,port-agency and freight forwarders should not be limited. Thismeans that the system of a limited number of port providers isimportant only for the activities that require location within aport, as the port area is physically limited. Therefore, the newAct on Navigation and Inland Ports from 2007, whose framehas been completed by sub-law acts during 2008, has replacedthe complex concession system for performing activities in inlandports by a more liberal approval system. On the basis ofthese, higher dynamics of work of port providers is enabled aswell as easier adjustment to market conditions. Furthermore,the main limitation factor that determines the number of portusers becomes the available physical space within a port, whichprovides undisturbed competition, along with larger offer ofport services that do not require that space. It is also importantto point out that the new Act specifically includes distributionand cargo logistics, also processing and improvement of goodsas well as industrial activities including production that enablecomplete economic utilization of port capacities into the existingport activities, thus significantly changing the role of the portitself as a logistic centre.

  17. Parameterization of rotational spectra

    International Nuclear Information System (INIS)

    Zhou Chunmei; Liu Tong

    1992-01-01

    The rotational spectra of the strongly deformed nuclei with low rotational frequencies and weak band mixture are analyzed. The strongly deformed nuclei are commonly encountered in the rare-earth region (e. g., 150 220). A lot of rotational band knowledge are presented

  18. Rotating reactors : a review

    NARCIS (Netherlands)

    Visscher, F.; Schaaf, van der J.; Nijhuis, T.A.; Schouten, J.C.

    2013-01-01

    This review-perspective paper describes the current state-of-the-art in the field of rotating reactors. The paper has a focus on rotating reactor technology with applications at lab scale, pilot scale and industrial scale. Rotating reactors are classified and discussed according to their geometry:

  19. Application of Game Theory and Uncertainty Theory in Port Competition between Hong Kong Port and Shenzhen Port

    Directory of Open Access Journals (Sweden)

    Thi Minh Hoang Do

    2015-06-01

    Full Text Available This paper unveils the strong competition in container cargo between Hong Kong Port which has been emerging as an international maritime center since the 1970s and Shenzhen Port which has recently gained remarkable achievements in the Pearl River Delta region. Among various competing strategies, the study focuses on the long-term one in which two ports will decide to compete by investing in capacity. The purpose of this research is to examine their decision making process and to suggest future strategic actions in the current situation. Within its scope, only economic profit brought back from the investment is considered. For this reason, an uncertain payoff two-person game model is developed where an uncertain factor of demand is involved. In applying Uncertainty theory (Liu, 2013, the two methods to solve the game are introduced, including uncertain statistics and the expected Nash Equilibrium strategy. The results obtained from this research generate meaningful suggestions for future competition plan for the two selected ports, which conclude that Shenzhen is the dominant port in this long-term strategy. Compared to existing works on the same topic, the paper shows its distinctiveness by studying the latest competitive situation with regard to the uncertain demand in the game model.

  20. Adaptive Port Planning under Disruptive Trends with focus on the case of The Port of Kuala Tanjung, Indonesia

    OpenAIRE

    Prakoso Andre; Taneja Poonam; Velinga Tiedo

    2018-01-01

    As a national strategic project, the Port of Kuala Tanjung draws significant attention at national and international level. Considering the semi-greenfield nature of the port, the diverse set of stakeholders, and the prevailing disruptive trends in the world port business, a robust first-phase port layout is required to kick-start the project and guarantee the overall sustainability of the port development. The objective of this research is to identify any uncertain or disruptive trends, both...

  1. Management of Artisanal Fishing Port: a Case Study on Labuhanhaji Fishing Port, South Aceh Regency, Aceh Province

    OpenAIRE

    NurJannah, Betri; ', Syaifuddin; Zain, Jonny

    2014-01-01

    A series survey activity was carried out for evaluating management function atlabuanhaji fishing port, South Aceh regency. This research was emphasis on planning, organizing, action and controlling at management pattern of labuhanhaji fishing port. The facilities of fishing port data and daily activities description of staff at labuhanhaji fishing port was used as additional information and consideration in management of labuhanhaji fishing port. Lack of good management was impact on staff an...

  2. The Re-Conceptualization of the Port Supply Chain as a Smart Port Service System: The Case of the Port of Salerno

    Directory of Open Access Journals (Sweden)

    Antonio Botti

    2017-04-01

    Full Text Available This paper proposes a re-conceptualization of the port supply chain as a smart service system, in accordance with the theory of service science. Starting from a short literature review about the port supply chain approach and service science, a new comprehensive framework is provided to better understand seaport dynamics and the creation of competitive port supply chains. The methodology used is the case study approach. The Authors examined the Port of Salerno (Italy and re-conceptualized it as a smart port service system. The originality of the work lies in the application of service science as a lens to re-conceptualize the port supply chain, that allows the implementation of a logistic framework. Both theoretical and practical implications are provided to enrich the literature about port supply chains and to support port operators.

  3. Nuclear analysis of the ITER Cryopump Ports

    International Nuclear Information System (INIS)

    Moro, Fabio; Villari, Rosaria; Flammini, Davide; Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael; Juarez, Rafael; Perez, Lucia; Petrizzi, Luigino

    2015-01-01

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  4. Nuclear analysis of the ITER Cryopump Ports

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Fabio, E-mail: fabio.moro@enea.it [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Villari, Rosaria; Flammini, Davide [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Juarez, Rafael; Perez, Lucia [UNED, Energetic Engineering Department, C/Juan del Rosal 12, Madrid (Spain); Petrizzi, Luigino [European Commission, DG Research & Innovation G5, CDMA 00/030, B-1049 Brussels (Belgium)

    2015-10-15

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  5. 78 FR 24069 - Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL

    Science.gov (United States)

    2013-04-24

    ... under Executive Order 13045, Protection of Children from Environmental Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an environmental risk to health...-AA00 Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL AGENCY...

  6. Single port laparoscopic ileocaecal resection for Crohn's disease: a multicentre comparison with multi-port laparoscopy

    NARCIS (Netherlands)

    Carvello, M.; de Groof, E. J.; de Buck van Overstraeten, A.; Sacchi, M.; Wolthuis, A. M.; Buskens, C. J.; D'Hoore, A.; Bemelman, W. A.; Spinelli, A.

    2018-01-01

    AimSingle port (SP) ileocaecal resection (ICR) is an established technique but there are no large studies comparing SP and multi-port (MP) laparoscopic surgery in Crohn's disease (CD). The aim of this study was to compare postoperative pain scores and analgesia requirements after SP and MP

  7. Shutdown dose rates at ITER equatorial ports considering radiation cross-talk from torus cryopump lower port

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Pampin, Raul [F4E, Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Levesy, Bruno [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Moro, Fabio [ENEA, Via Enrico Fermi 45, Frascati, Rome (Italy); Suarez, Alejandro [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2015-11-15

    Shutdown dose rates for planned maintenance purposes is an active research field in ITER. In this work the radiation (neutron and gamma) cross-talk between ports in the most conservative case foreseen in ITER is investigated: the presence of a torus cryopump lower port, mostly empty for pumping efficiency reasons. There will be six of those ports: #4, #6, #10, #12, #16 and #18. The equatorial ports placed above them will receive a significant amount of additional radiation affecting the shutdown dose rates during in situ maintenance activities inside the cryostat, and particularly in the port interspace area. In this study a general situation to all the equatorial ports placed above torus cryopump lower ports is considered: a generic diagnostics equatorial port placed above the torus cryopump lower port (LP#4). In terms of shutdown dose rates at equatorial port interspace after 10{sup 6} s of cooling time, 405 μSv/h has been obtained, of which 160 μSv/h (40%) are exclusively due to radiation cross-talk from a torus cryopump lower port. Equatorial port activation due to only “local neutrons” contributes 166 μSv/h at port interspace, showing that radiation cross-talk from such a lower port is a phenomenon comparable in magnitude to the neutron leakage though the equatorial port plug.

  8. Rotating Stars in Relativity

    Directory of Open Access Journals (Sweden)

    Stergioulas Nikolaos

    2003-01-01

    Full Text Available Rotating relativistic stars have been studied extensively in recent years, both theoretically and observationally, because of the information they might yield about the equation of state of matter at extremely high densities and because they are considered to be promising sources of gravitational waves. The latest theoretical understanding of rotating stars in relativity is reviewed in this updated article. The sections on the equilibrium properties and on the nonaxisymmetric instabilities in f-modes and r-modes have been updated and several new sections have been added on analytic solutions for the exterior spacetime, rotating stars in LMXBs, rotating strange stars, and on rotating stars in numerical relativity.

  9. Dynamism Patterns of Western Mediterranean Cruise Ports and the Coopetition Relationships Between Major Cruise Ports

    Directory of Open Access Journals (Sweden)

    Esteve-Perez Jeronimo

    2018-03-01

    Full Text Available The Mediterranean Sea has seen an increase of ports hosting cruise ships during the first fifteen years of the 21st century. The increase in cruise ship presence in Mediterranean ports is associated with the dynamism of cruise traffic in recent years, with an average annual growth of 7.45% for cruise passengers worldwide during the period of 1990-2015. Cruise traffic is a maritime business that is primarily composed of two elements, maritime affairs and tourism. This article focuses on the maritime component. With the growth of the cruise industry, cruise lines have been forced to seek new ports to meet demand in an attempt to create differentiated products based on the ports that compose the itinerary. The itinerary system of cruise traffic makes the cruise ports depend on one another to design an itinerary. This feature results in both complex geographic relationships in the design of a cruise itinerary and complex competitive/cooperative relationships between ports. The aim of this article is to present the hierarchic picture of a sample of 29 cruise ports in the Western Mediterranean region during the period of 2000-2015. To achieve this goal, a port size classification is proposed and a shift-share analysis at the inter- and intra-group size level is applied. Moreover, concentration measures are used to determine the changes in the levels of market concentration. Furthermore, a dynamic model is proposed to determine the competitive or cooperative relationships between cruise ports. The proposed model is applied to the largest ports with data from the 2001-2015 period.

  10. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    1999-01-01

    In this article two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very offten the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belo...... approximations to the Riemannian metric, and that the subsequent corrections are inherient in the least squares estimation. Keywords: averaging rotations, Riemannian metric, matrix, quaternion......In this article two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very offten the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...

  11. Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

    International Nuclear Information System (INIS)

    Yeo, Inhwan Jason; Patyal, Baldev; Mandapaka, Anant; Jung, Jae Won; Yi, Byong Yong; Kim, Jong Oh

    2013-01-01

    . However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT

  12. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  13. Specialization and Flexibility in Port Cargo Handling

    Directory of Open Access Journals (Sweden)

    Hakkı KİŞİ

    2016-11-01

    Full Text Available Cargo handling appears to be the fundamental function of ports. In this context, the question of type of equipment and capacity rate need to be tackled with respect to cargo handling principles. The purpose of this study is to discuss the types of equipment to be used in ports, relating the matter to costs and capacity. The question is studied with a basic economic theoretical approach. Various conditions like port location, size, resources, cargo traffic, ships, etc. are given parameters to dictate the type and specification of the cargo handling equipment. Besides, a simple approach in the context of cost capacity relation can be useful in deciding whether to use specialized or flexible equipment. Port equipment is sometimes expected to be flexible to handle various types of cargo as many as possible and sometimes to be specialized to handle one specific type of cargo. The cases that might be suitable for those alternatives are discussed from an economic point of view in this article. Consequently, effectiveness and efficiency criteria play important roles in determining the handling equipment in ports.

  14. Pollution prevention at ports: clearing the air

    International Nuclear Information System (INIS)

    Bailey, Diane; Solomon, Gina

    2004-01-01

    Seaports are major hubs of economic activity and of environmental pollution in coastal urban areas. Due to increasing global trade, transport of goods through ports has been steadily increasing and will likely continue to increase in the future. Evaluating air pollution impacts of ports requires consideration of numerous sources, including marine vessels, trucks, locomotives, and off-road equipment used for moving cargo. The air quality impacts of ports are significant, with particularly large emissions of diesel exhaust, particulate matter, and nitrogen oxides. The health effects of these air pollutants to residents of local communities include asthma, other respiratory diseases, cardiovascular disease, lung cancer, and premature mortality. In children, there are links with asthma, bronchitis, missed school days, and emergency room visits. The significance of these environmental health impacts requires aggressive efforts to mitigate the problem. Approaches to mitigation encompass a range of possibilities from currently available, low-cost approaches, to more significant investments for cleaner air. Examples of the former include restrictions on truck idling and the use of low-sulfur diesel fuel; the latter includes shore-side power for docked ships, and alternative fuels. A precautionary approach to port-related air pollution would encourage local production of goods in order to reduce marine traffic, greener design for new terminals, and state-of-the art approaches to emissions-control that have been successfully demonstrated at ports throughout the world

  15. Fewer-than-four ports versus four ports for laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Rossi, Michele; Davidson, Brian R

    2014-02-20

    Traditionally, laparoscopic cholecystectomy is performed using two 10-mm ports and two 5-mm ports. Recently, a reduction in the number of ports has been suggested as a modification of the standard technique with a view to decreasing pain and improving cosmesis. The safety and effectiveness of using fewer-than-four ports has not yet been established. To assess the benefits (such as improvement in cosmesis and earlier return to activity) and harms (such as increased complications) of using fewer-than-four ports (fewer-than-four-ports laparoscopic cholecystectomy) versus four ports in people undergoing laparoscopic cholecystectomy for any reason (symptomatic gallstones, acalculous cholecystitis, gallbladder polyp, or any other condition). We searched the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2013), MEDLINE, EMBASE, Science Citation Index Expanded, and the World Health Organization International Clinical Trials Registry Platform portal to September 2013. We included all randomised clinical trials comparing fewer-than-four ports versus four ports, that is, with standard laparoscopic cholecystectomy that is performed with two ports of at least 10-mm incision and two ports of at least 5-mm incision. Two review authors independently identified the trials and extracted the data. We analysed the data using both the fixed-effect and the random-effects models. For each outcome, we calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) based on intention-to-treat analysis, whenever possible. We found nine trials with 855 participants that randomised participants to fewer-than-four-ports laparoscopic cholecystectomy (n = 427) versus four-port laparoscopic cholecystectomy (n = 428). Most trials included low anaesthetic risk participants undergoing elective laparoscopic cholecystectomy. Seven of the nine trials used a single port laparoscopic cholecystectomy and the remaining two trials used three-port laparoscopic

  16. The complex challenge of repairing the gantry steelwork on the first generation magnox storage pond at Sellafield: Legacy Waste Storage, First Generation Magnox Storage Pond - 59133

    International Nuclear Information System (INIS)

    Richardson, Ian E.

    2012-01-01

    This paper puts into context the challenges that were faced when repairing the Gantry Steelwork of the First Generation Magnox Storage Pond (FGMSP). The First Generation Magnox Fuel Storage Pond (FGMSP) provided fuel storage and de-canning capability from the early 1960's until 1986. A significant programme of work has been underway since the completion of operational activities to support the programmes strategic intent of retrieving and storing all legacy wastes, and remediating the structure of the plant to support decommissioning activities. A key enabler to the retrievals programme is the Pond Skip Handler Machine (SHM), removed from service in 2002 following the discovery of significant signs of corrosion and distress, an inevitable consequence of being located in a coastal, salt laden environment. The SHM provides sole capability to access and retrieve the inventory of over 1000 fuel skips. It is also fundamental to future operations and the deployment of de-sludging equipment to recover significant bulk sludge's from the pond floor. Failure of the SHM steelwork gantry at worst case could potentially result in the Skip Handler Machine being derailed. This has some potential to damage to the pond structure and at worst case may result in local radiological and environmental consequences. This paper will examine the challenges faced by the team as they successfully defined, planned and executed remedial work to a specific aspect of the civil structure, the SHM gantry rail system, using a purpose built refurbishment platform; the Gantry Refurbishment System. The paper will examine how an 'innovative' approach was adopted to resolve the related issues of: - Refurbishing an aged structure to meet extended future operational demands. - The application of pragmatic engineering solutions against current codes and standards including seismic performance; - Provision of safe access for the workforce to undertake the refurbishment work against significant radiological

  17. Determination of the attenuation due to the treatment table according to the angle of gantry for system treatments verification Delta4

    International Nuclear Information System (INIS)

    Linares Doblado, R.; Mateo Rodriguez, B.; Perucha Ortega, M.

    2013-01-01

    The optimal solution to the problem of absorption into the table would be to incorporate it into the system of planning as one structure more, but not all planners incorporate this functionality. As an alternative solution, approximate, this paper evaluates through measures in the system mentioned effect, with the aim of obtaining a table of absorption vs. angle of gantry, for different field sizes that will be used to correct the dose values recorded by the QA system. Research on the effect of the corrections in the histograms of dose and gamma. (Author)

  18. View of the moving head of the gantry machine and the working area containingthe supply and assembly platforms (trays in green).

    CERN Multimedia

    Alan Honma

    1999-01-01

    The robotic assembly machine consists of the gantry positioning systemoutfitted with pickup tooling heads and camera+microscope for accurateposition measurements. The procedure is to place the components onthe working platforms and the machine applies glue, picks and placesthe silicon sensors and front-end hybrids onto the frames. The components are held in place by vacuum to prevent movement untilthe glue has cured. Up to four modules can be assembled at one time.The platforms are removable allowing assembly to continue on a newset of modules.

  19. Computed tomography in endocrine orbitopathy: Effects of different gantry tilt and patient positioning on measurements of eye muscle thickness, and possibilities for correction

    International Nuclear Information System (INIS)

    Markl, A.; Hilbertz, T.; Mayr, B.; Lissner, J.; Pickardt, C.R.

    1986-01-01

    Thickening of eye muscles in endocrine orbitopathy can be demonstrated particularly impressively in coronary computed tomograms. However, when measuring the height and width of rectus eye muscles manifesting pathologic changes, the measurement is increased by a deviation from the coronary section plane; this is due to different tilting of the gantry. This often leads to an incorrect stage classification and makes objective observation of the course (e.g., under therapy) impossible. By converting the measured values into the actual extent of the muscles by means of the cosine set, appreciable changes in the pattern and frequency of affection of the rectus eye muscles were found in 121 patients examined. (orig.) [de

  20. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  1. PERFORMANCE ASSESSMENT IN OPERATING DRY PORTS

    Directory of Open Access Journals (Sweden)

    Ciortescu Cezar-Gabriel

    2010-12-01

    Full Text Available In this paper, an approach for recognizing and defining correct and operable performance will be presented with the purpose of evaluating the effectiveness and efficiency of processes in dry ports (inland intermodal hubs. The challenge in evaluating the possible improvements of the underlying processes lies in the special nature and the complex structure of dry ports. It is important to consider that all the processes are highly interconnected and that changes in parameters in one process also have an impact on parameters in other processes. Furthermore, the performance of dry ports, seen as the backbone of the system, has a significant impact on the overall performance of the whole transportation network.

  2. Development Possibilities of the Port of Koper

    Directory of Open Access Journals (Sweden)

    Igor Trupac

    2002-03-01

    Full Text Available The extent to which Slovenia will exploit its good geographictransport position, whether it will be merely a transportcorridor or assume an additional quality (e.g. a distributioncentre or a logistic centre will depend on a cluster of circumstances.The importance will also be laid on how Slovenia willpresent itself and what it will offer to Europe and the rest of theworld. One of its best assets is the Port of Koper (favourable position,good condition, capacities in the frame of the whole logisticsystem.A larger volume of transport and consequently be/fer exploitationof the Port of Koper will in the future depend on increasedtransit. However, to acquire new cargo, the mere installationand modernisation of port infrastructure and rise in thequality of services may not be sufficient: it will also require goodconnections to the hinterland.

  3. Smartphone audio port data collection cookbook

    Directory of Open Access Journals (Sweden)

    Kyle Forinash

    2018-06-01

    Full Text Available The audio port of a smartphone is designed to send and receive audio but can be harnessed for portable, economical, and accurate data collection from a variety of sources. While smartphones have internal sensors to measure a number of physical phenomena such as acceleration, magnetism and illumination levels, measurement of other phenomena such as voltage, external temperature, or accurate timing of moving objects are excluded. The audio port cannot be only employed to sense external phenomena. It has the additional advantage of timing precision; because audio is recorded or played at a controlled rate separated from other smartphone activities, timings based on audio can be highly accurate. The following outlines unpublished details of the audio port technical elements for data collection, a general data collection recipe and an example timing application for Android devices.

  4. INSTITUTIONAL AND MANAGEMENT STRUCTURE OF RUSSIAN ARCTIC SEA PORTS

    Directory of Open Access Journals (Sweden)

    P. A. Bryzgalov

    2012-01-01

    Full Text Available Institutional and management structure of any sea port is a system of interaction between commercial enterprises engaged in cargo operations in port, a subsidiary of Rosmorport FSUE, Sea Port Authority and a number of services (immigration, customs and sanitary-veterinary. Institutional and management structure of some Russian Arctic sea ports is significantly different from the typical one resulting in management problems for these socially significant objects of the Russian Arctic. A plan is proposed to improve the organizational and administrative structure of these ports based on the use of domestic and international experience in port infrastructure management including effective cooperation between the state and the private business.

  5. Port Site Infections After Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Mumtaz KH Al-Naser

    2017-06-01

    Full Text Available Background: Port site infection (PSI is an infrequent surgical site infection that complicates laparoscopic surgery but has a considerable influence in the overall outcome of laparoscopic cholecystectomy. The aim of this study was to evaluate factors that influence PSI after laparoscopic cholecystectomies and to analyze which of these factors can be modified to avoid PSI in a trail to achieve maximum laparoscopic advantages. Methods: A prospective descriptive qualitative study conducted on patients who underwent laparoscopic cholecystectomies. Swabs were taken for culture & sensitivity in all patients who developed PSI. Exploration under general anaesthesia, for patients, had deep surgical site infections and wound debridement was done, excisional biopsies had been taken for histopathological studies, and tissue samples for polymerase chain reaction for detection of mycobacterium tuberculosis was done. All patients were followed up for six months postoperatively. Factors as gender, site of infected port, type of microorganism, acute versus chronic cholecystitis, type of infection (superficial or deep infection and intraoperative spillage of stones, bile or pus were analyzed in our sample. Results: Port site infection rate was recorded in 40/889 procedures (4.5%, higher rates were observed in male patients 8/89 (8.9%, in acute cholecystitis 13/125 (10.4%, when spillage of bile, stones or pus occurred 24/80 (30%, and at epigastric port 32/40 (80%. Most of the PSI were superficial infections 77.5% with non-specific microorganism 34/40 (85%. Conclusion: There is a significant association of port site infection with spillage of bile, stones, or pus, with the port of gallbladder extraction and with acute cholecystitis. Especial consideration should be taken in chronic deep surgical site infection as mycobacterium tuberculosis could be the cause. Most of the PSIs are superficial and more common in males.

  6. Gating-by-rotation: a solution to the problem of intratreatment motion in helical tomotherapy

    International Nuclear Information System (INIS)

    Kapatoes, J.M.; Olivera, G.H.; Schloesser, E.A.; Pearson, D.W.; Balog, J.P.; Ruchala, K.J.; Schmidt, R.; Reckwerdt, P.J.; Mehta, M.P.; Mackie, T.R.

    2001-01-01

    Purpose: To assess the feasibility of addressing intratreatment motion issues in helical tomotherapy by gating the treatments by rotation. Intratreatment motion is a problem common to all IMRT techniques. Traditional methods of gating in conformal radiotherapy and some forms of IMRT are not applicable to helical tomotherapy due to the continuous rotation of the gantry. An alternative method is presented. Materials and Methods: Rotation-gating in helical tomotherapy is the process in which one rotation of treatment is immediately followed by a rotation of non-treatment. This on-off strategy is repeated for the full treatment volume. During the treatment rotations, the patient is required to hold their breath while the intensity-modulated fan beam deposits dose. For the non-treatment rotations, the patient is allowed to breathe freely as all leaves of the MLC will be closed, the accelerator disabled, or both. The couch indexes normally for treatment rotations and holds the patient stationary during non-treatment rotations. An investigation was conducted to assess the feasibility of rotation-gating. Film was placed between two hemispheres of a water phantom and a continuous helical delivery was carried out with all leaves opened. The film was replaced and another treatment was performed employing rotation-gating. The two films were compared to assess the process. The films were irradiated to dose levels within the linear region of the film response curve (maximum film dose ∼35 cGy). Films were also acquired with all leaves closed to quantify leakage dose through the collimation systems. Results: Central profiles for the inferior-superior direction (parallel to the direction of translation) for both films are displayed in Figure 1. The profiles agree very well, illustrating that a rotation-gated treatment closely mimics a continuous helical delivery. The only significant discrepancy lay in the tails of the profiles: a higher film dose is seen for the rotation

  7. Development of the Bosaso Port Somalia

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1988-01-01

    The first stage of the port of Bosaso will be completed within half a year's time. It offers accomodation for one general cargo/Ro-Ro vessel of 5,000 DWT plus 350 meters of quays for small cargo vessels and fishing boats. Hinterlands for handling of the goods are arranged along the quays. Areas...... for long term storage of goods and storage of oil are not yet provided. The first stage represents a significant development in the transport system of Somalia in being the most prosperous port in the northern Somalia because of its position at the terminal of the new north-south national main road and its...

  8. Operational Optimization in Port Container Terminals

    DEFF Research Database (Denmark)

    As a result of the significant increase in worldwide containerized transportation the development of efficient handling systems in marine terminals has become very important for port competitiveness. In order to optimize the productivity the total handling time for containers in the terminal must...... be minimized. An overview of the different operational problems in port container terminals is presented and an aggregated model and solution approach is shown. Next, there will be focused on the yard storage problem and a mathematical formulation and solution proposals will be presented....

  9. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  10. Strategic Planning for Port Development: Improvement of Container Transit from the Iranian Southern Ports Terminals

    Directory of Open Access Journals (Sweden)

    Homayoun Yousefi

    2013-09-01

    Full Text Available The author attempts to highlight the significance of the Iranian southern ports development strategy planning which allows for the maximum container transit with minimum resources such as service capacities, human resources, and financial potential in order to expand the Iranian container transit. It should be noted that the strategic objectives, the business strategy and its implementation can be arranged only after the port vision and mission obviously delineated. For the purpose of improving the outcome of the ports operational management, it is recommended to concentrate on new strategies such as exploit of transit corridors for development of the Iranian South Ports. The main part of this paper is dedicated to evaluate the role of container transit from the Iranian south ports terminals from various transport corridors in order to improve Maritime Transport in Iran. The importance of defin¬ing the existing and potential competitors at the Persian Gulf and making a comparison between their and our own strengths and weaknesses is of utmost importance. Sometimes, the real business opportunities and threats are placed beyond one’s own line of indus¬try and business. It is therefore necessary to make a careful analysis of the port environment. After the port competition and environment have been analyzed, it would be possible to initiate the building of the SWOT analysis for the Iranian Southern Container Terminals such as Khoramshahr, Imam Khomani, Busher, Bandar Abbas and Chabahar port which have suitable strategic position as transit base in the region. The SWOT analysis method is therefore applied aiming at defining the weaknesses and strengths of the economic subjects as well as opportunities and threats coming from the environment. The next segment of this paper is dedicated to consider the role of dry ports and the International North-South Transit Corridor for the purpose of improving the Iranian container trade.

  11. Analysis of laparoscopic port site complications: A descriptive study.

    Science.gov (United States)

    Karthik, Somu; Augustine, Alfred Joseph; Shibumon, Mundunadackal Madhavan; Pai, Manohar Varadaraya

    2013-04-01

    The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. Prospective descriptive study. In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. Of the 570 patients undergoing laparoscopic surgery, 17 (3%) had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI) was the most frequent (n = 10, 1.8%), followed by port site bleeding (n = 4, 0.7%), omentum-related complications (n = 2; 0.35%), and port site metastasis (n = 1, 0.175%). Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit.

  12. Rotations with Rodrigues' vector

    International Nuclear Information System (INIS)

    Pina, E

    2011-01-01

    The rotational dynamics was studied from the point of view of Rodrigues' vector. This vector is defined here by its connection with other forms of parametrization of the rotation matrix. The rotation matrix was expressed in terms of this vector. The angular velocity was computed using the components of Rodrigues' vector as coordinates. It appears to be a fundamental matrix that is used to express the components of the angular velocity, the rotation matrix and the angular momentum vector. The Hamiltonian formalism of rotational dynamics in terms of this vector uses the same matrix. The quantization of the rotational dynamics is performed with simple rules if one uses Rodrigues' vector and similar formal expressions for the quantum operators that mimic the Hamiltonian classical dynamics.

  13. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    2001-01-01

    In this paper two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very often the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong ...... approximations to the Riemannian metric, and that the subsequent corrections are inherent in the least squares estimation.......In this paper two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very often the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...

  14. Current epidemiology of hypertension in Port Harcourt metropolis ...

    African Journals Online (AJOL)

    Current epidemiology of hypertension in Port Harcourt metropolis, Rivers State ... the University of Port Harcourt Teaching Hospital formed the cohort for this study. ... is high and only a small fraction of hypertensives are aware of their condition.

  15. Logistics Road map for Smart SeaPorts

    Directory of Open Access Journals (Sweden)

    Khaled Gaber EL Sakty

    2016-12-01

    Full Text Available In the digital world, a smart concept became an essential feature for port organizations to serve as intelligent hubs in the world transport networks.  Smart ports are the trend for the future long-term strategies. Henceforth, ports aims at contributing to sustainable growth by establishing the appropriate conditions for the adoption of new management energy models based on low environmental impact and triggering innovation of both technologies and processes. The scope of this paper is to examine three main issues of smart ports; smart port arctic logistics roadmap, smart port challenges and obstacles in arctic port areas, and the criteria and Key Performance Indicators guiding the assessment of ports against this concept. The main purpose is to develop a smart arctic logistics road map for the future.

  16. An Appraisal of Hospital Based Blood Pressure Control in Port ...

    African Journals Online (AJOL)

    Alasia Datonye

    Department of Internal Medicine, College of Health Sciences, University of Port Harcourt,. Port Harcourt ... The assessment of hypertension control and evaluation of the impact of poor ..... An updated coronary risk profile: A statement from.

  17. The “diamond port configuration”: A standardised laparoscopic ...

    African Journals Online (AJOL)

    This covered patient position, port insertion, technical aspects of intestinal resection and perioperative management. In particular, a diamond configuration for ports was agreed upon. Data were prospectively collected, and included patient demographics, operative times, conversion rates and postoperative outcomes.

  18. Deepwater Ports in US waters as of August 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Deepwater Port Licensing Program is the application process designed to promote the construction of LNG and oil deepwater ports. This license system was...

  19. System аnalysis concession maritime trade ports

    Directory of Open Access Journals (Sweden)

    Y.V. Shmatock

    2015-03-01

    Full Text Available The article proves the significance of maritime commercial ports as strategic for the country. The urgency of port concessions to improve transport infrastructure. The definition of ports in terms of system analysis and determination of management port. Outlined the sequence of system analysis concessions maritime trade ports in the table. Selection of qualified managers is based on the concession tender under prescribed conditions. These criteria should be considered when determining the concessionaire. These stages of the concession tender. Meeting the needs of the economy, international trade, public inquiries into transportation of goods is not possible without the efficient operation of maritime trade ports. Only complex technological modernization of maritime trade ports will enable them to take leadership positions. Tree depicted objectives effectively manage commercial sea port. Therefore, initiation of concessions needs to implement measures to achieve the talented and skillful result.

  20. FHWA operations support : port peak pricing program evaluation

    Science.gov (United States)

    2009-01-01

    This report evaluates the applicability, Federal policy implications, and possible public and private sector roles related to peak pricing strategies at ports and intermodal facilities in the U.S. A number of ports and intermodal terminals are consid...

  1. Radiation and Shipping Port Security | RadTown USA | US ...

    Science.gov (United States)

    2017-08-07

    Cargo comes into the U.S. from all over the world. Ports can ensure safety by: Screening cargo for radiation before it gets here. Safely handling any radioactive material that needs to pass through a port.

  2. The Port Elizabeth Electric Tramway Case: Is the Meaning Ascribed ...

    African Journals Online (AJOL)

    The Port Elizabeth Electric Tramway Case: Is the Meaning Ascribed to the Phrase “In the Production of the Income” By Watermeyer AJP in the Port Elizabeth Electric Tramway Case Still Religiously Followed Today?

  3. Port wine stain on a child's face (image)

    Science.gov (United States)

    Port wine stains are always present at birth. In an infant, they are flat, pink, vascular lesions. Common locations ... may be present anywhere on the body. Port wine stains may appear in association with other syndromes.

  4. Reduced-port robotic total mesorectal resection for rectal cancer using a single-port access: a technical note.

    Science.gov (United States)

    Bae, Sung Uk; Jeong, Woon Kyung; Baek, Seong Kyu

    2017-12-01

    Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, pure single-port laparoscopic rectal cancer surgery is challenging because of the difficulties in creating triangulation and applying the laparoscopic staplers with sufficient distal margins in the narrow pelvic cavity. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, the pure single-port laparoscopic rectal cancer operation is challenging. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. We performed a single-port plus an additional port robotic operation using a robotic single-port access through the umbilical incision, and the wristed robotic instruments were inserted through an additional robotic port in the right lower quadrant. The total operative and docking times were 310 min and 25 min, respectively. The total number of lymph nodes harvested was 12, and the proximal and distal resection margins were 11.1 and 2 cm, respectively. The patient was discharged on postoperative day 12 uneventfully. Based on a representative case, reduced-port robotic total mesorectal excision for rectal cancer using the single-port access appears to be feasible and safe. This approach could overcome the limitations of single-port laparoscopic rectal surgery.

  5. Adaptive control of port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; Edelmayer, András

    2010-01-01

    In this paper an adaptive control scheme is presented for general port-Hamiltonian systems. Adaptive control is used to compensate for control errors that are caused by unknown or uncertain parameter values of a system. The adaptive control is also combined with canonical transformation theory for

  6. Sewage Disposal in Port Harcourt, Nigeria.

    Science.gov (United States)

    Ayotamuno, M. J.

    1993-01-01

    This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…

  7. Transparency in port-Hamiltonian based telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2005-01-01

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper we exploit a behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian based teleoperators. Furthermore we provide a transparency analysis of

  8. Transparency in Port-Hamiltonian-Based Telemanipulation

    NARCIS (Netherlands)

    Secchi, Cristian; Stramigioli, Stefano; Fantuzzi, Cesare

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper, we exploit the behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian-based teleoperators. Furthermore, we provide a transparency analysis of

  9. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  10. Remote Identification of Port Scan Toolchains

    NARCIS (Netherlands)

    Ghiëtte, Vincent; Blenn, N.; Doerr, C.; Badra, Mohamad; Pau, Giovanni; Vassiliou, Vasos

    2016-01-01

    Port scans are typically at the begin of a chain of events that will lead to the attack and exploitation of a host over a network. Since building an effective defense relies on information what kind of threat an organization is facing, threat intelligence outlining an actor’s modus operandi is a

  11. Stuctures in hydraulic engineering : Port Infrastructure

    NARCIS (Netherlands)

    de Gijt, J.G.

    2007-01-01

    Lecture notes on the planning and design of port infrastructure, like quay walls as gravity structures, sheet-piles, jetties and ro-ro facilties; anchoring of walls. Discussion of the loads on quay walls, jetties and dolphins. Construction of quay walls. Risk analysis, fender design. Scour problems

  12. Port Hamiltonian modeling of Power Networks

    NARCIS (Netherlands)

    van Schaik, F.; van der Schaft, Abraham; Scherpen, Jacquelien M.A.; Zonetti, Daniele; Ortega, R

    2012-01-01

    In this talk a full nonlinear model for the power network in port–Hamiltonian framework is derived to study its stability properties. For this we use the modularity approach i.e., we first derive the models of individual components in power network as port-Hamiltonian systems and then we combine all

  13. Agile Port and High Speed Ship Technologies

    Science.gov (United States)

    2009-12-31

    Alternative Shipboard Powering Systems for Naval and Regulatory Review • The Evaluation and Implementation Plan for Southern California Maglev ...Ackerman". CSULB Foundation Annual Report. CSULB Foundation, Long Beach, CA. December 2005. " Maglev Technology ’Conveys’ Port Transportation Solutions...34. Newsflash. College of Engineering, California State University, Long Beach. Cover page. Spring 2006 Hanson, Kristopher. "Engineers Tout Maglev at

  14. The Global View on Port State Control

    NARCIS (Netherlands)

    S. Knapp (Sabine); Ph.H.B.F. Franses (Philip Hans)

    2006-01-01

    textabstractThis report is the second part of a PhD project entitled "The Econometrics of Maritime Safety – Recommendations to Enhance Safety at Sea" which is based on 183,000 port state control inspections and 11,700 casualties from various data sources. Its overall objective is to provide

  15. Photoacoustic imaging of port-wine stains

    NARCIS (Netherlands)

    Kolkman, Roy G. M.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton G.

    2008-01-01

    BACKGROUND AND OBJECTIVE: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. STUDY DESIGN/MATERIALS AND METHODS: PAI uses pulsed

  16. Photoacoustic Imaging of Port-Wine Stains

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Mulder, M.J.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton

    2008-01-01

    Background and Objective: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. - Study Design/Materials and Methods: PAI uses

  17. Structures in hydraulic engineering : Port Infrastructure

    NARCIS (Netherlands)

    de Gijt, J.G.

    2004-01-01

    In history harbours were places of 'natural' shelter, ships could be safely anchored, however loading and unloading facilities were generally non existent apart from human labour. On the other hand ports are man made places of shelter purpose built for efficient transfer of cargo. The distinction

  18. Port-Hamiltonian Systems on Open Graphs

    NARCIS (Netherlands)

    Schaft, A.J. van der; Maschke, B.M.

    2010-01-01

    In this talk we discuss how to define in an intrinsic manner port-Hamiltonian dynamics on open graphs. Open graphs are graphs where some of the vertices are boundary vertices (terminals), which allow interconnection with other systems. We show that a directed graph carries two natural Dirac

  19. Role of Flexibility in Sustainable Port Development

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Ros, R.

    2012-01-01

    Sustainability has become a high profile objective in all aspects of our lives, including the development of our infrastructures. Flexibility can enhance sustainability endeavors, yet its contribution is not clear to most. In this paper we investigate the role of flexibility in sustainable port

  20. 33 CFR 165.761 - Security Zones; Port of Palm Beach, Port Everglades, Port of Miami, and Port of Key West, Florida.

    Science.gov (United States)

    2010-07-01

    ... of the law enforcement boats and cruise ship tenders which will mark a transit lane in channel. (ii... east of the law enforcement vessels and cruise ship tenders, which will mark a transit lane in the..., tug boats and contracted security vessels may assist the Coast Guard Captain of the Port under the...

  1. Single port access for laparoscopic lateral segmentectomy.

    Science.gov (United States)

    Inoue, Yoshihiro; Asakuma, Mitsuhiro; Hirokawa, Fumitoshi; Hayashi, Michihiro; Shimizu, Tetsunosuke; Uchiyama, Kazuhisa

    2017-12-01

    Single-port access laparoscopic lateral segmentectomy (LLS) has been developed as a novel minimally invasive surgery. We have experience with this LLS technique. To report our technique and patients' postoperative course in a series of single-port access LLS performed in our department. We also examine the cosmetic outcome, safety, and utility of the procedure. Between February 2010 and October 2016, 54 patients who underwent single- or multiple-port laparoscopic or open lateral segmentectomy (LS) were retrospectively analyzed with respect to cosmetic outcome, safety, and utility. In the single LLS group, the laparoscopic procedure was successfully completed for all 14 patients. The median operative time was significantly shorter in the single LLS group (123 min; range: 50-270 min) than in the other groups. Estimated blood loss was also significantly lower in the single LLS group (10 ml; range: 0-330 ml). During the first 7 postoperative days, the visual analog scale pain score and the use of additional analgesia were not significantly different between groups. The single LLS group had a 7.1% complication rate (Clavien-Dindo classification > IIIA); this was not significantly different between groups. Single-port access LLS is a procedure with excellent cosmetic results, although, with regard to invasiveness, there are no major differences from conventional LLS.

  2. HomePort ZigBee Adapter

    DEFF Research Database (Denmark)

    Pedersen, Thomas; Smedegaard, Jacob Haubach; Hansen, Rene

    the existing tool, Homeport, to act as a middleware and bridge between ConLAN's existing network and the ZigBee network. This report primarily discusses three possible solutions for constructing this bridge and current status on the implementation of a Develco SmartAMM and Zigbee stack for HomePort....

  3. Optimizing yard operations in port container terminals

    DEFF Research Database (Denmark)

    Kallehauge, Louise Sibbesen

    2005-01-01

    This paper deals with the problem of positioning containers in a yard block of a port container terminal. The objective of the container positioning problem (CPP) is to minimise the total handling time in the block, i.e. the time required for storage and reshuffling of containers. One...

  4. Regional Hub port development : the case of Montevideo, Uruguay

    OpenAIRE

    Wilmsmeier, Gordon; Martínez Zarzoso, Inmaculada; Fiess, Norbert

    2011-01-01

    This paper reflects on port development in Uruguay in an environment of trilateral interport competition. The regional characteristics of port development in terms of their geographical, functional and operational characteristics are discussed by analysing the port system’s evolution. The case of Montevideo as the success or failure of a regional hub port development strategy is analysed in detail. Particular attention is given to the evolution and impact of the liner shipping service network...

  5. Process for evaluating overweight truck corridors serving coastal port regions and border ports of entry

    Science.gov (United States)

    2017-08-01

    Coastal and inland ports, regional mobility authorities, cities, and counties located near or along the Texas Gulf Coast, and along the border with Mexico, have been granted authority by the state legislature to establish permitted overweight truck c...

  6. National Port Strategy Assessment: Reducing Air Pollution and Greenhouse Gases at U.S. Ports

    Science.gov (United States)

    The assessment finds that air pollution at the Nation's ports can be significantly reduced by implementing currently available strategies and technologies to reduce emissions of harmful pollutants from diesel vehicles and engines.

  7. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    Science.gov (United States)

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  8. Generic Diagnostic Port Integration for the Equatorial Port Plug of ITER

    International Nuclear Information System (INIS)

    Doceul, L.; Chappuis, Ph.; Portafaix, Ch.; Guillaume, T.; Bruyere, Ch.; Walker, Ch.; Ingesson, Ch.; Ciattaglia, E.; Salasca, S.; Eric, T.

    2006-01-01

    ITER requires an extensive set of diagnostic systems to provide several key functions such as protection of the device, input to plasma control systems and evaluation of the plasma performance. Most of these diagnostics system are to be integrated in port plugs, which are water cooled stainless steel structures (approximately: 50 t, 2 m x 2 m x 4 m) inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, supporting the diagnostic equipment (within the primary vacuum, on the primary vacuum boundary and in the port interspace). CEA (Commissariat l'Energie Atomique) has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug EQ01. The specific CEA contributions were to perform the general engineering, structural and thermal analysis. These detailed analysis have highlighted some design issues which were worked out through different solutions. This paper will contain the description of the engineering activities performed such as: - The conceptual design of the EQ01 and the associated diagnostics, such as the visible and infrared optical diagnostic, - The static mechanical calculations, taking into account the electromagnetic loads occurring during fast transient plasma events, - The dynamic calculation constituted of modal and transient analysis under the same electromagnetic loads to estimate the dynamic amplification factor due to the resonance phenomenon, - The thermal assessment under the neutronic load of the water-cooled stainless steel structure, - The seismic response of the port plug inside the vacuum vessel, taking into account the ground spectra and soil conditions in the Cadarache site. (author)

  9. The Development of the Regional Sea Port Infrastructure on the Basis of Dry Port

    Directory of Open Access Journals (Sweden)

    Aleksandr Nelevich Rakhmangulov

    2016-09-01

    Full Text Available This article contributes to the solution of the relevant problem of the seaport infrastructure development for the purpose of increasing the cargo turnover in the regions of seaport location as well as to improve the quality of freight traffic on the basis of the creation of container hinterlands — dry ports. The options of dry ports as the potentially effective solution to increase the cargo turnover of existing seaports, improve the timeliness of freight transportation and overcome the environmental problems of the regions of seaport location are shown. This work analyzes the transport infrastructure of the region, the cargo turnover of major Russian sea and dry ports as well as the experience of creating dry ports in the Russian Federation and abroad. The authors propose the system of parameters for dry ports, which are recommended for the assessment of seaport infrastructure development scenarios on the stage of strategic planning. The authors have developed the approach of optimal values determination of the main parameters of dry ports by simulation modeling method. The features of construction and research of the simulation models of system “seaport — dry port” in programming software AnyLogic are considered. The results of modeling experiments with a developed simulation model are provided. This model is aimed to assess the maximum estimated capacity of the existing seaport in the conditions of the increasing irregularity of cargo traffic, and also to determine the optimum parameters of the constructed «dry port». The obtained dependencies as a result of modeling experiments prove the adequacy of the selected main parameters of dry ports for the effective evaluation of the scenarios of the strengthening of carrying and estimated capacity of existing seaports on the stage of strategic planning. The article shows that the methodology of this research can be used by the investors and public authorities as grounds for a decision on

  10. Hub port competition and welfare effects of strategic privatization

    NARCIS (Netherlands)

    Czerny, A.I.; Hoffler, F.; Mun, S.

    2014-01-01

    Private operation of port facilities is becoming increasingly common worldwide. We investigate the effect of port privatization in a setting with two ports located in different countries, each serving their home market but also competing for the transshipment traffic from a third region. Each

  11. Performance Effects of the Corporatisation of Port of Rotterdam Authority

    NARCIS (Netherlands)

    P.W. de Langen (Peter); C. Heij (Christiaan)

    2013-01-01

    textabstractPort of Rotterdam Authority is a publicly owned but corporatized port development company. In 2004, this organisation was transformed from a municipal department to an independently operating company. The corporatisation intended to improve the overall performance of the port of

  12. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    Directory of Open Access Journals (Sweden)

    Soner Esmer

    2016-03-01

    Full Text Available Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector and evaluate their effect on various aspects of non-price competition. We start with a general conceptual framework to explain how competition in the sector can be affected by various factors and then propose an analytical framework on non-price competition. The analytical model is then used to support the design of a survey questionnaire. Next, hypothesis tests are conducted using exploratory factor analysis (EFA and structural equation modeling (SEM and data collected from a survey of Turkish ports. Based on the analysis results, the implications for port management and future research are also discussed.

  13. Asteroid rotation rates

    International Nuclear Information System (INIS)

    Binzel, R.P.; Farinella, P.

    1989-01-01

    Within the last decade the data base of asteroid rotation parameters (rotation rates and lightcurve amplitudes) has become sufficiently large to identify some definite rends and properties which can help us to interpret asteroid collisional evolution. Many significant correlations are found between rotation parameters and diameter, with distinct changes occurring near 125 km. The size range, which is also the diameter above which self-gravity may become important, perhaps represents a division between surviving primordial asteroids and collisional fragments. A Maxwellian is able to fit the observed rotation rate distributions of asteroids with D>125 km, implying that their rotation rates may be determined by collisional evolution. Asteroids with D<125 km show an excess of slow rotators and their non-Maxwellian distributions suggests that their rotation rates are more strongly influenced by other processes, such as the distribution resulting from their formation in catastrophic disruption events. Other correlations observed in the data set include different mean rotation rates for C, S and M type asteroids implying that their surface spectra are indicative of bulk properties

  14. The spatial rotator

    DEFF Research Database (Denmark)

    Rasmusson, Allan; Hahn, Ute; Larsen, Jytte Overgaard

    2013-01-01

    This paper presents a new local volume estimator, the spatial rotator, which is based on measurements on a virtual 3D probe, using computer assisted microscopy. The basic design of the probe builds upon the rotator principle which requires only a few manual intersection markings, thus making...

  15. Superconducting rotating machines

    International Nuclear Information System (INIS)

    Smith, J.L. Jr.; Kirtley, J.L. Jr.; Thullen, P.

    1975-01-01

    The opportunities and limitations of the applications of superconductors in rotating electric machines are given. The relevant properties of superconductors and the fundamental requirements for rotating electric machines are discussed. The current state-of-the-art of superconducting machines is reviewed. Key problems, future developments and the long range potential of superconducting machines are assessed

  16. Fundamental Relativistic Rotator

    International Nuclear Information System (INIS)

    Staruszkiewicz, A.

    2008-01-01

    Professor Jan Weyssenhoff was Myron Mathisson's sponsor and collaborator. He introduced a class of objects known in Cracow as '' kreciolki Weyssenhoffa '', '' Weyssenhoff's rotating little beasts ''. The Author describes a particularly simple object from this class. The relativistic rotator described in the paper is such that its both Casimir invariants are parameters rather than constants of motion. (author)

  17. SMAP Faraday Rotation

    Science.gov (United States)

    Le Vine, David

    2016-01-01

    Faraday rotation is a change in the polarization as signal propagates through the ionosphere. At L-band it is necessary to correct for this change and measurements are made on the spacecraft of the rotation angle. These figures show that there is good agreement between the SMAP measurements (blue) and predictions based on models (red).

  18. Units of rotational information

    Science.gov (United States)

    Yang, Yuxiang; Chiribella, Giulio; Hu, Qinheping

    2017-12-01

    Entanglement in angular momentum degrees of freedom is a precious resource for quantum metrology and control. Here we study the conversions of this resource, focusing on Bell pairs of spin-J particles, where one particle is used to probe unknown rotations and the other particle is used as reference. When a large number of pairs are given, we show that every rotated spin-J Bell state can be reversibly converted into an equivalent number of rotated spin one-half Bell states, at a rate determined by the quantum Fisher information. This result provides the foundation for the definition of an elementary unit of information about rotations in space, which we call the Cartesian refbit. In the finite copy scenario, we design machines that approximately break down Bell states of higher spins into Cartesian refbits, as well as machines that approximately implement the inverse process. In addition, we establish a quantitative link between the conversion of Bell states and the simulation of unitary gates, showing that the fidelity of probabilistic state conversion provides upper and lower bounds on the fidelity of deterministic gate simulation. The result holds not only for rotation gates, but also to all sets of gates that form finite-dimensional representations of compact groups. For rotation gates, we show how rotations on a system of given spin can simulate rotations on a system of different spin.

  19. The rotating universe

    International Nuclear Information System (INIS)

    Ruben, G.; Treder, H.J.

    1987-01-01

    For a long time the question whether the universe rotates or not is discussed. Aspects of Huygens, Newton, Mach and other important historical scientists in this field are reported. The investigations of the mathematician Kurt Groedel in order to prove the rotation of the universe are illustrated. Kurt Groedel has shown that Einstein's gravitational equations of general relativity theory and the cosmological postulate of global homogeneity of cosmic matter (that is the Copernical principle) are not contradictionary to a rotating universe. Abberation measurements, position determination by means of radiointerferometry and methods for the determination of the rotation of the universe from the isotropy of the background radiation are presented. From these experiments it can be concluded that the universe seems not to rotate as already Einstein expected

  20. Rotation sensor switch

    International Nuclear Information System (INIS)

    Sevec, J.B.

    1978-01-01

    A protective device to provide a warning if a piece of rotating machinery slows or stops is comprised of a pair of hinged weights disposed to rotate on a rotating shaft of the equipment. When the equipment is rotating, the weights remain in a plane essentially perpendicular to the shaft and constitute part of an electrical circuit that is open. When the shaft slows or stops, the weights are attracted to a pair of concentric electrically conducting disks disposed in a plane perpendicular to the shaft and parallel to the plane of the weights when rotating. A disk magnet attracts the weights to the electrically conducting plates and maintains the electrical contact at the plates to complete an electrical circuit that can then provide an alarm signal

  1. Rotating stars in relativity.

    Science.gov (United States)

    Paschalidis, Vasileios; Stergioulas, Nikolaos

    2017-01-01

    Rotating relativistic stars have been studied extensively in recent years, both theoretically and observationally, because of the information they might yield about the equation of state of matter at extremely high densities and because they are considered to be promising sources of gravitational waves. The latest theoretical understanding of rotating stars in relativity is reviewed in this updated article. The sections on equilibrium properties and on nonaxisymmetric oscillations and instabilities in f -modes and r -modes have been updated. Several new sections have been added on equilibria in modified theories of gravity, approximate universal relationships, the one-arm spiral instability, on analytic solutions for the exterior spacetime, rotating stars in LMXBs, rotating strange stars, and on rotating stars in numerical relativity including both hydrodynamic and magnetohydrodynamic studies of these objects.

  2. A two-in-one Faraday rotator mirror exempt of active optical alignment.

    Science.gov (United States)

    Wan, Qiong; Wan, Zhujun; Liu, Hai; Liu, Deming

    2014-02-10

    A two-in-one Faraday rotator mirror was presented, which functions as two independent Faraday rotation mirrors with a single device. With the introduction of a reflection lens as substitution of the mirror in traditional structure, this device is characterized by exemption of active optical alignment for the designers and manufacturers of Faraday rotator mirrors. A sample was fabricated by passive mechanical assembly. The insertion loss was measured as 0.46 dB/0.50 dB for the two independent ports, respectively.

  3. Technical guides/ methodological guide in case of tripping of a radioactivity detection gantry; Guides techniques / guide methodologique en cas de declenchement d'un portique de detection de radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The most of operators of reprocessing plants or waste disposal plants have equipment to detect radiation as gantry. To answer to a clarification need procedures can be followed during the tripping of a gantry. Procedures have been made by cards, they follow the regulation in force in the area of radiation protection and environment protection. With these cards there are an annexe giving the terms noticed in the cards, a glossary on radioactivity as well a list of organisms approved by the government to proceed to control for the workers protection against the hazards of ionizing radiations. (N.C.)

  4. Adaptive Port Planning under Disruptive Trends with focus on the case of the Port of Kuala Tanjung, Indonesia

    NARCIS (Netherlands)

    Taneja, P.; Velinga, Tiedo

    2018-01-01

    As a national strategic project, the Port of Kuala Tanjung draws significant attention at national and international level. Considering the semi-greenfield nature of the port, the diverse set of stakeholders, and the prevailing disruptive trends in the world port business, a robust first-phase

  5. PC interfacing using Centronics, RS232 and game ports

    CERN Document Server

    An, Pei

    1998-01-01

    The main links with your PC and the outside world are the centronic port, used for connecting the printer, the RS232 port, used for the mouse, and the games port for a joystick. This book explores how these input/output (I/O) ports can be put to use through a range of other interfacing applications. This is especially useful for laptop and palmtop PCs which cannot be fitted with internal I/O cards. A novel approach is taken by this book, combining the hardware through which the ports can be explored, and the software programming needed to carry out a range of experiments.Circuits are p

  6. The Port Hope area initiative municipal involvement

    International Nuclear Information System (INIS)

    Austin, Rick; Stevenson, Mark

    2006-01-01

    Port Hope (Canada) contains one of the world's oldest nuclear facility sites. From the 1930's through to the 1970's, processing residues from radium refining facilities located at the Port Hope Harbour were being stored and/or deposited on numerous sites throughout the municipality. For a variety of reasons, including spillage of material during transportation and un-monitored or unauthorized diversion of materials, many private and public properties in the municipality were contaminated with low level radioactive waste. Over the past 30 years, the community has demanded that the nuclear industry and the federal government clean up the mess left in Port Hope. In the 1980's and 1990's, the federal government sought to fulfill its commitment to clean up over one million cubic metres of contaminated material remaining in Port Hope but was unable to find a solution. The Low Level Radioactive Waste Management Siting Task Force worked in trying to find a home for historic LLRW in the 1980's and 1990's. It is only within the past 6 years that Port Hope's community began to see the 'light at the end of the tunnel'. And, the light began to shine when the communities took the issue of long term management of the waste into their own hands and proposed possible solutions to the federal government. So the Port Hope Area Initiative is a community-based initiative. In this paper the author presents some of the reasons for success (so far) and some opportunities and challenges that his municipality, and specifically municipal Council, faces as a partner in this Environmental Assessment and project development process. He addresses some of the key elements of the Project that he believes have led to the success of the Project to this point, including: the Legal Agreement and Agreement Monitoring process; the Property Value Protection Program; the Hosting Fee; the Municipal veto on some decisions; the end Use as an asset to the Community; the Value of Peer Review. He also touches

  7. Benchmark dynamics in the environmental performance of ports.

    Science.gov (United States)

    Puig, Martí; Michail, Antonis; Wooldridge, Chris; Darbra, Rosa Mari

    2017-08-15

    This paper analyses the 2016 environmental benchmark performance of the port sector, based on a wide representation of EcoPorts members. This is the fifth time that this study has been conducted as an initiative of the European Sea Ports Organisation (ESPO). The data and results are derived from the Self-Diagnosis Method (SDM), a concise checklist against which port managers can self-assess the environmental management of their port in relation to the performance of the EcoPorts membership. The SDM tool was developed in the framework of the ECOPORTS project (2002-2005) and it is managed by ESPO. A total number of 91 ports from 20 different European Maritime States contributed to this evaluation. The main results are that air quality remains as the top environmental priority of the respondent ports, followed by energy consumption and noise. In terms of environmental management, the study confirms that key components are commonly implemented in the majority of European ports. 94% of contributing ports have a designated environmental manager, 92% own an environmental policy and 82% implement an environmental monitoring program. Waste is identified as the most monitored issue in ports (80%), followed by energy consumption (73%) and water quality (70%). Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Clinical retrospective control study of single-port laparoendoscopic and multi-port laparoscopic ovarian cystectomy].

    Science.gov (United States)

    Liu, X; Wen, M K; Liu, H Y; Sun, D W; Lang, J H; Fan, Q B; Shi, H H

    2017-10-25

    Objective: To investigate clinical outcomes of laparoendoscopic single-site ovarian cystectomy compared with traditional multi-port laparoscopic ovarian cystectomy. Methods: Data of 81 patients with ovarian cystectomy from January 2016 to May 2017, the single-site group ( n= 40) and the multi-port group ( n= 41) in Peking Union Medical College Hospital were retrospectively collected. The outcomes of single-site and multi-port groups were analyzed and compared, including: postoperative fever, operation time, blood loss, hemoglobin change, surgical complications, postoperative pain score, postoperative analgesic requirements, body image scale and cosmetic score, length of hospital stay, postoperative total cost. Results: No complication was found in two groups. No difference was found in postoperative fever, blood loss, hemoglobin change, postoperative pain score, length of hospital stay, and total cost between the two groups (all P> 0.05). Operation time was (50±20) minutes in single-site group, and (40±15) minutes in multi-port group; postoperative analgesic requirements was 28%(11/40) in single-site group, and 7%(4/41) in multi-port group; cosmetic score was 22.6±2.6 in single-site group, and 17.3±2.6 in multi-port group; body image scale was 5.7±1.2 in single-site group, and 6.2±1.2 in multi-port group; these four clinical parameters were statistical differences (all P< 0.05). Conculsion: Laparoendoscopic single-site ovarian cystectomy is feasible and safe, although it could't relieve the postoperative pian, it do offer a higher cosmetic satisfaction.

  9. Robotic right middle lobectomy with a subxiphoid utility port.

    Science.gov (United States)

    Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel

    2018-06-01

    We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.

  10. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  11. Feasibility of Reduced Port Laparoscopic Colectomy for Colon Cancer.

    Science.gov (United States)

    Tsutsumi, Soichi; Morita, Hiroki; Fujii, Takaaki; Suto, Toshinaga; Yajima, Reina; Takada, Takahiro; Asao, Takayuki; Kuwano, Hiroyuki

    2015-06-01

    Reduced port laparoscopic surgery has recently emerged as a method to improve the cosmetic results of conventional laparoscopic surgery. We reported our technique of reduced port laparoscopic colectomy using 3-port and short-time outcomes. Between 2005 and 2012, we performed 161 reduced port laparoscopic colectomies using the 3-port technique. Data analyzed in-cluded age, gender, body mass index (BMI), duration of surgery, number of harvested lymph nodes, and duration of hospital stay. All of the cases were successfully performed using the 3-port procedure. The median durations of surgery and postoperative hospital stay were 140 mm (range 75-463 mm) and 9 days (range 5-38 days), respectively. No mortality was associated with this technique. Reduced port laparoscopic colectomy is feasible and may have advantages over conventional laparoscopic colectomy.

  12. Port performance evaluation tool based on microsimulation model

    Directory of Open Access Journals (Sweden)

    Tsavalista Burhani Jzolanda

    2017-01-01

    Full Text Available As port performance is becoming correlative to national competitiveness, the issue of port performance evaluation has significantly raised. Port performances can simply be indicated by port service levels to the ship (e.g., throughput, waiting for berthing etc., as well as the utilization level of equipment and facilities within a certain period. The performances evaluation then can be used as a tool to develop related policies for improving the port’s performance to be more effective and efficient. However, the evaluation is frequently conducted based on deterministic approach, which hardly captures the nature variations of port parameters. Therefore, this paper presents a stochastic microsimulation model for investigating the impacts of port parameter variations to the port performances. The variations are derived from actual data in order to provide more realistic results. The model is further developed using MATLAB and Simulink based on the queuing theory.

  13. Rotation, Stability and Transport

    Energy Technology Data Exchange (ETDEWEB)

    Connor, J. W.

    2007-07-01

    Tokamak plasmas can frequently exhibit high levels of rotation and rotation shear. This can usually be attributed to various sources: injection of momentum, e.g. through neutral beams, flows driven by plasma gradients or torques resulting from non-ambipolar particle loss; however, the source sometimes remains a mystery, such as the spontaneous rotation observed in Ohmic plasmas. The equilibrium rotation profile is given by the balance of these sources with transport and other losses; the edge boundary conditions can play an important role in determining this profile . Such plasma rotation, particularly sheared rotation, is predicted theoretically to have a significant influence on plasma behaviour. In the first place, sonic flows can significantly affect tokamak equilibria and neoclassical transport losses. However, the influence of rotation on plasma stability and turbulence is more profound. At the macroscopic level it affects the behaviour of the gross MHD modes that influence plasma operational limits. This includes sawteeth, the seeding of neoclassical tearing modes, resistive wall modes and the onset of disruptions through error fields, mode locking and reconnection. At the microscopic level it has a major effect on the stability of ballooning modes, both ideal MHD and drift wave instabilities such as ion temperature gradient (ITG) modes. In the non-linear state, as unstable drift waves evolve into turbulent structures, sheared rotation also tears apart eddies, thereby reducing the resulting transport. There is considerable experimental evidence for these effects on both MHD stability and plasma confinement. In particular, the appearance of improved confinement modes with transport barriers, such as edge H-mode barriers and internal transport barriers (ITBs) appears to correlate well with the presence of sheared plasma rotation. This talk will describe the theory underlying some of these phenomena involving plasma rotation, on both macroscopic and microscopic

  14. On Job Rotation

    OpenAIRE

    Metin M. Cosgel; Thomas J. Miceli

    1998-01-01

    A fundamental principle of economics with which Adam Smith begins The Wealth of Nations is the division of labor. Some firms, however, have been pursuing a practice called job rotation, which assigns each worker not to a single and specific task but to a set of several tasks among which he or she rotates with some frequency. We examine the practice of job rotation as a serious alternative to specialization, with three objectives. The first is to consider current and historical examples of job...

  15. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter......The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...

  16. United Kingdom Ireland coal ports directory

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    The directory gives details of ports at 65 locations in the UK and Ireland. For each port, the directory lists the name of the terminal; the name, address, contact name and numbers of the terminal owner and of the terminal operator; and the name and telephone/fax numbers of ship's agents. It also give details, for each terminal, where available, of tidal rise, access routes, vessel maxima, working hours, coal traders and handlers, discharge facilities, daily discharge rate, coal loading facilities, daily loading rate, stocking area dimensions and capacity, stocking area facilities and inland transport infrastructure. Research for the directory was undertaken by S. Fazal and C. Measham of Sheffield Hallam University, Business School.

  17. Major impact in shipping and port sectors

    Energy Technology Data Exchange (ETDEWEB)

    Cottrill, K.

    1985-08-01

    The impact of information technology (IT) on operations efficiency in the transport field is comparable to the revolution brought on by the use of containers. The author examines the influence of IT on British shipping in terms of documentation, cargo tracking, and trend analysis on the operational side and communications links on the structural side. Shipboard computers were slow to penetrate the traditional bastion of the ship's bridge, but the effects of automation are already evident in the size of crews and their work roles. Britain is a world leader in specialized networks in the ports sector. A European-based initiative for a European ports database is in the development stage. It is essential for the IT networks to be compatible both nationally and internationally for the technology to be worthwhile.

  18. Rotator cuff - self-care

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000358.htm Rotator cuff - self-care To use the sharing features on ... and shoulder exercises may help ease your symptoms. Rotator Cuff Problems Common rotator cuff problems include: Tendinitis , which ...

  19. Ethnopharmacology of Medicinal Plants in Genaveh Port

    Directory of Open Access Journals (Sweden)

    Leila Moradi

    2014-11-01

    Full Text Available Background: Ethnopharmacology has been seen as a multidisciplinatary approach for novel drug discovery by providing valuable data about medicinal plants in different cultures. The aim of this ethnopharmacological study was to identify medicinal plants of the Genaveh port in the North of Persian Gulf. Material and Methods: The medical uses of medicinal plants were gathered from 30 local informants by face to face interview. The relative frequency of citation (FRC and cultural importance (CI indices were calculated. Results: A total of 93 medicinal plants belonging to 55 families were identified. Plantago psyllium, Teucrium polium, Peganum harmala, Descuraninia sophia, Cichorium intybus, Achillea erophora DC, Matricarria charmomilla and Citrolus colocynthis had the highest cultural importance indices. Plantago psyllium, Descuraninia sophia and Zataria multiflora had the highest FRC indices. The highest medical uses were for gastrointestinal diseases, gynocological diseases, respiratory disorders, infectious diseases, nature of cool and metabolic disorders, respectively. In addition to the use of these plants to treat diseases as in Iran’s traditional medicine, people in the Genaveh port particularly use Plantago psyllium for drainage of infective boils and abscesses, cough, skin diseases, Teucrium polium for diabetes mellitus, wound washing and sterilizing, Peganum harmala for uterus infections and abdominal cramps, Descuraninia sophia for heart diseases and heatstroke, Cichorium intybus for heatstroke and liver diseases, Achillea eriophora DC for reflex, diabetes mellitus and wound healing, Matricarria charmomilla for seizure and dysmenorrhea, Citrolus colocynthis for hemorrhoid, diabetes mellitus and rheumatism and Zataria multiflora for sedation, abdominal pain and respiratory diseases. Conclusion: There is a vast variety of medicinal plants in Genaveh port. Although most of therapeutic applications of these plants in the Genaveh port are the

  20. Globalization and wine business: Port wine

    OpenAIRE

    Rebelo, Joao; Correia, Leonida; Caldas, Jose Vaz

    2007-01-01

    In the past two decades the world has seen acceleration in the process of globalisation, affecting virtually all industries and consumers. The wine sector is no exception, witnessing increased exports and imports, decreasing consumption per capita in the producing countries, and a wave of direct foreign investment and mergers and acquisitions in the industry. Among European wine producers the Port wine can be seen as a representative case of globalisation and as a benchmark, because almost 90...

  1. Laser Treatment of Port Wine Stains

    Science.gov (United States)

    Majaron, Boris; Nelson, J. Stuart

    Port wine stain (PWS), also called nevus flammeus, is a congenital, cutaneous vascular malformation involving post-capillary venules which produce a light pink to red to dark-red-violet discoloration of human skin [1]. PWS occurs in an estimated 3 children per 1000 live births, affecting males and females and all racial groups equally [2]. There appears to be no hereditary predilection for PWS within families. There are no known risk factors or ways to prevent PWS.

  2. 3D visualization of port simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Horsthemke, W. H.; Macal, C. M.; Nevins, M. R.

    1999-06-14

    Affordable and realistic three dimensional visualization technology can be applied to large scale constructive simulations such as the port simulation model, PORTSIM. These visualization tools enhance the experienced planner's ability to form mental models of how seaport operations will unfold when the simulation model is implemented and executed. They also offer unique opportunities to train new planners not only in the use of the simulation model but on the layout and design of seaports. Simulation visualization capabilities are enhanced by borrowing from work on interface design, camera control, and data presentation. Using selective fidelity, the designers of these visualization systems can reduce their time and efforts by concentrating on those features which yield the most value for their simulation. Offering the user various observational tools allows the freedom to simply watch or engage in the simulation without getting lost. Identifying the underlying infrastructure or cargo items with labels can provide useful information at the risk of some visual clutter. The PortVis visualization expands the PORTSIM user base which can benefit from the results provided by this capability, especially in strategic planning, mission rehearsal, and training. Strategic planners will immediately reap the benefits of seeing the impact of increased throughput visually without keeping track of statistical data. Mission rehearsal and training users will have an effective training tool to supplement their operational training exercises which are limited in number because of their high costs. Having another effective training modality in this visualization system allows more training to take place and more personnel to gain an understanding of seaport operations. This simulation and visualization training can be accomplished at lower cost than would be possible for the operational training exercises alone. The application of PORTSIM and PortVis will lead to more efficient

  3. Umbilical KeyPort bilateral laparoscopic orchiectomy in patient with complete androgen insensitivity syndrome

    Directory of Open Access Journals (Sweden)

    Felipe P. Andrade

    2012-10-01

    Full Text Available MAIN FINDINGS: A 22-year-old woman with complete androgen insensitivity syndrome (CAIS presenting with primary amenorrhea and normal female external genitalia was referred for laparoscopic gonadectomy. She had been diagnosed several years earlier but was reluctant to undergo surgery. CASE HYPOTHESIS: Diagnosis of this X-linked recessive inherited syndrome characterizes by disturbance of virilization in males with an AR mutation, XY karyotipe, female genitalia and severely undescended testis with risk of malignization. The optimal time to orchidectomy is not settled; neither the real risk of malignancy in these patients. Early surgery impacts development of a complete female phenotype, with enlargement of the breasts. Based on modern diagnostic imaging using DCE-MRI and surgical technology with single port laparoscopic access we hypothesize that the optimum time for gonadectomy is not at the time of diagnosis, but once feminization has completed. PROMISING FUTURE IMPLICATIONS: An umbilical laparoendoscopic single-site access for bilateral gonadectomy appears to be the first choice approach as leaves no visible incision and diminishes the psychological impact of surgery in a patient with CAIS absolutely reassured as female. KeyPort, a single port access with duo-rotate instruments developed by Richard Wolf facilitates this surgery and allows excellent cosmetic results.

  4. Managing Temporal Knowledge in Port Management Systems

    Directory of Open Access Journals (Sweden)

    Anita Gudelj

    2006-05-01

    Full Text Available Large ports need to deal with a number of disparate activities:the movement of ships, containers and other cargo, theloading and unloading of ships and containers, customs activities.As well as human resources, anchorages, channels, lighters,tugs, berths, warehouse and other storage spaces have to beallocated and released. The efficient management of a port involvesmanaging these activities and resources, managing theflows of money involved between the agents providing and usingthese resources, and providing management information.Many information systems will be involved.Many applications have to deal with a large amount of datawhich not only represent the perceived state of the real world atpresent, but also past and/or future states. These applicationsare not served adequately by today's computer managementand database systems. In particular, deletions and updates insuch systems have destructive semantics. This means that previousdatabase contents (representing previous perceived statesof the real world cannot be accessed anymore.A review of how define temporal data models, based ongeneralizing a non-temporal data model in to a temporal one toimprove port management is presented. This paper describes apractical experiment which supports managing temporal dataalong with the corresponding prototype implementations.

  5. Underwater Calibration of Dome Port Pressure Housings

    Science.gov (United States)

    Nocerino, E.; Menna, F.; Fassi, F.; Remondino, F.

    2016-03-01

    Underwater photogrammetry using consumer grade photographic equipment can be feasible for different applications, e.g. archaeology, biology, industrial inspections, etc. The use of a camera underwater can be very different from its terrestrial use due to the optical phenomena involved. The presence of the water and camera pressure housing in front of the camera act as additional optical elements. Spherical dome ports are difficult to manufacture and consequently expensive but at the same time they are the most useful for underwater photogrammetry as they keep the main geometric characteristics of the lens unchanged. Nevertheless, the manufacturing and alignment of dome port pressure housing components can be the source of unexpected changes of radial and decentring distortion, source of systematic errors that can influence the final 3D measurements. The paper provides a brief introduction of underwater optical phenomena involved in underwater photography, then presents the main differences between flat and dome ports to finally discuss the effect of manufacturing on 3D measurements in two case studies.

  6. A new system for port films.

    Science.gov (United States)

    Sephton, R; Green, M; Fitzpatrick, C

    1989-01-01

    A novel system for port films is described which incorporates a high-quality fluorescent screen lying behind a flat, heavy-metal screen or filter and the film pressed between them is not an X ray type but a single-emulsion, very high contrast graphics or line-type film. In experimental comparisons using 4 MV, 6 MV, and 25 MV photon beams, the new Peter MacCallum Cancer Institute (PMCI) system produced clearer images, about X2 higher in contrast yet lower in relative noise levels, than did the conventional commercially-available systems which use x-ray film between heavy-metal screens. Direct clinical comparisons, chiefly using 6 MV accelerators, confirmed that anatomical details were correspondingly better visualized and in general, the PMCI port film could be matched against the simulator radiograph with greater confidence. Routine use for greater than 2 yr in this Institute (4000 new patients per yr, 20 cassettes made for use with four 6 MV accelerators) has shown the PMCI system to be an economical and practical device, giving reproducibly high quality images in all the common port film applications.

  7. Unique problems of hydrocarbon contamination for ports

    International Nuclear Information System (INIS)

    Rice, D.W.

    1991-01-01

    Since the early 1900s, port facilities in the United States have been involved in the import and export of petroleum products. The WORLDPORT L.A. is a 7,000 acre land and water area that is administered by the Department of The City of Los Angeles under a tidelands grant from the State of California for the purposes of commerce, navigation, and fisheries. Over half of the oil-refining of California lies within 20 miles of WORLDPORT L.A. It is therefore not surprising that the port is a major hub for the handling of crude oil and petroleum products, including gasoline, aviation gas/jet fuel, and marine fuels. This paper reports that it is also not surprising that port facilities, given their long history of handling petroleum products, contain areas where soils and groundwater are contaminated with hydrocarbons. This contamination is localized but can be extensive. Petroleum and petrochemical products are handled at terminal facilities that are leased to oil companies

  8. Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

    Science.gov (United States)

    Berbeco, Ross I; Jiang, Steve B; Sharp, Gregory C; Chen, George T; Mostafavi, Hassan; Shirato, Hiroki

    2004-01-21

    The design of an integrated radiotherapy imaging system (IRIS), consisting of gantry mounted diagnostic (kV) x-ray tubes and fast read-out flat-panel amorphous-silicon detectors, has been studied. The system is meant to be capable of three main functions: radiographs for three-dimensional (3D) patient set-up, cone-beam CT and real-time tumour/marker tracking. The goal of the current study is to determine whether one source/panel pair is sufficient for real-time tumour/marker tracking and, if two are needed, the optimal position of each relative to other components and the isocentre. A single gantry-mounted source/imager pair is certainly capable of the first two of the three functions listed above and may also be useful for the third, if combined with prior knowledge of the target's trajectory. This would be necessary because only motion in two dimensions is visible with a single imager/source system. However, with previously collected information about the trajectory, the third coordinate may be derived from the other two with sufficient accuracy to facilitate tracking. This deduction of the third coordinate can only be made if the 3D tumour/marker trajectory is consistent from fraction to fraction. The feasibility of tumour tracking with one source/imager pair has been theoretically examined here using measured lung marker trajectory data for seven patients from multiple treatment fractions. The patients' selection criteria include minimum mean amplitudes of the tumour motions greater than 1 cm peak-to-peak. The marker trajectory for each patient was modelled using the first fraction data. Then for the rest of the data, marker positions were derived from the imager projections at various gantry angles and compared with the measured tumour positions. Our results show that, due to the three dimensionality and irregular trajectory characteristics of tumour motion, on a fraction-to-fraction basis, a 'monoscopic' system (single source/imager) is inadequate for

  9. A discrete time-varying internal model-based approach for high precision tracking of a multi-axis servo gantry.

    Science.gov (United States)

    Zhang, Zhen; Yan, Peng; Jiang, Huan; Ye, Peiqing

    2014-09-01

    In this paper, we consider the discrete time-varying internal model-based control design for high precision tracking of complicated reference trajectories generated by time-varying systems. Based on a novel parallel time-varying internal model structure, asymptotic tracking conditions for the design of internal model units are developed, and a low order robust time-varying stabilizer is further synthesized. In a discrete time setting, the high precision tracking control architecture is deployed on a Voice Coil Motor (VCM) actuated servo gantry system, where numerical simulations and real time experimental results are provided, achieving the tracking errors around 3.5‰ for frequency-varying signals. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1999

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Nobuo; Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru [Fujitsu Ltd., Tokyo (Japan); Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yatake, Yo-ichi [Hitachi Ltd., Tokyo (Japan)

    2001-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system, the SX-4 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 18 codes in fiscal 1999. These results are reported in 3 parts, i.e., the vectorization and the parallelization part on vector processors, the parallelization port on scalar processors and the porting part. In this report, we describe the porting. In this porting part, the porting of Assisted Model Building with Energy Refinement code version 5 (AMBER5), general purpose Monte Carlo codes far neutron and photon transport calculations based on continuous energy and multigroup methods (MVP/GMVP), automatic editing system for MCNP library code (autonj), neutron damage calculations for materials irradiations and neutron damage calculations for compounds code (SPECTER/SPECOMP), severe accident analysis code (MELCOR) and COolant Boiling in Rod Arrays, Two-Fluid code (COBRA-TF) on the VPP500 system and/or the AP3000 system are described. (author)

  11. Social Media Usage Patterns in Port Industry: Implications for Port Promotion and Public Relations

    Directory of Open Access Journals (Sweden)

    Aylin ÇALIŞKAN

    2018-03-01

    Full Text Available While social media has been penetrating the daily lives of individuals, the businesses have started to develop new strategical approaches for using social media tools, since they understand the importance of this new area. This study aims to take a step on the gap about social media marketing in the port industry. The focused sample is container ports located in Turkey, but to gain more meaningful insights, a comparison is also made with the ports of Los Angeles, Rotterdam, and Antwerp. The post set on Facebook, which covers the 8 months’ period, was analyzed through a social media analytics software, and the most attractive topics and engagement levels were determined. It was found that the most attractive posts of ports with high engagement levels do not include any statement, image, or video about port service, infrastructure and superstructure, investments, or success stories. At the end of the study, suggestions are developed by supporting with real cases for ports’ social media management.

  12. Rotating universe models

    International Nuclear Information System (INIS)

    Tozini, A.V.

    1984-01-01

    A review is made of some properties of the rotating Universe models. Godel's model is identified as a generalized filted model. Some properties of new solutions of the Einstein's equations, which are rotating non-stationary Universe models, are presented and analyzed. These models have the Godel's model as a particular case. Non-stationary cosmological models are found which are a generalization of the Godel's metrics in an analogous way in which Friedmann is to the Einstein's model. (L.C.) [pt

  13. Rotation Invariance Neural Network

    OpenAIRE

    Li, Shiyuan

    2017-01-01

    Rotation invariance and translation invariance have great values in image recognition tasks. In this paper, we bring a new architecture in convolutional neural network (CNN) named cyclic convolutional layer to achieve rotation invariance in 2-D symbol recognition. We can also get the position and orientation of the 2-D symbol by the network to achieve detection purpose for multiple non-overlap target. Last but not least, this architecture can achieve one-shot learning in some cases using thos...

  14. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    International Nuclear Information System (INIS)

    Zhu, X; Chang, S; Cullip, T; Yuan, L; Zhang, X; Lian, J; Tang, X; Tracton, G; Dooley, J

    2014-01-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity

  15. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X [Univ. of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Chang, S [UNC School of Medicine, Chapel Hill, NC (United States); Cullip, T [UNC Hospitals, Chapel Hill, NC (United States); Yuan, L; Zhang, X [Duke University, Durham, NC (United States); Lian, J; Tang, X [UniversityNorth Carolina, Chapel Hill, NC (United States); Tracton, G; Dooley, J [University of North Carolina, Chapel Hill, NC (United States)

    2014-06-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity.

  16. Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation

    International Nuclear Information System (INIS)

    Cameron, C

    2005-01-01

    Sweeping-window arc therapy (SWAT) is a variation of intensity-modulated radiation therapy (IMRT) with direct aperture optimization (DAO) that is initialized with a leaf sequence of sweeping windows that move back and forth periodically across the target as the gantry rotates. This initial sequence induces modulation in the dose and is assumed to be near enough to a minimum to allow successful optimization, done with simulated annealing, without requiring excessive leaf speeds. Optimal beam weights are calculated analytically, with easy extension to allow for variable beam weights. In this paper SWAT is tested on a phantom model and clinical prostate case. For the phantom, constant and variable beam weights are used. Although further work (in particular, improving the dose model) is required, the results show SWAT to be a feasible approach to generating deliverable dynamic arc treatments that are optimized

  17. Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C [Division of Radiation Physics, Department of Radiation Oncology, Stanford Cancer Center, 875 Blake Wilbur Drive, Rm G-233, Stanford, CA 94305-5847 (United States)

    2005-09-21

    Sweeping-window arc therapy (SWAT) is a variation of intensity-modulated radiation therapy (IMRT) with direct aperture optimization (DAO) that is initialized with a leaf sequence of sweeping windows that move back and forth periodically across the target as the gantry rotates. This initial sequence induces modulation in the dose and is assumed to be near enough to a minimum to allow successful optimization, done with simulated annealing, without requiring excessive leaf speeds. Optimal beam weights are calculated analytically, with easy extension to allow for variable beam weights. In this paper SWAT is tested on a phantom model and clinical prostate case. For the phantom, constant and variable beam weights are used. Although further work (in particular, improving the dose model) is required, the results show SWAT to be a feasible approach to generating deliverable dynamic arc treatments that are optimized.

  18. Process and overview of diagnostics integration in ITER ports

    International Nuclear Information System (INIS)

    Drevon, J.M.; Walsh, M.; Andrew, P.; Barnsley, R.; Bertalot, L.; Bock, M. de; Bora, D.; Bouhamou, R.; Direz, M.F.; Encheva, A.; Fang, T.; Feder, R.; Giacomin, T.; Hellermann, M. von; Jakhar, S.; Johnson, D.; Kaschuk, Y.; Kusama, Y.; Lee, H.G.; Levesy, B.

    2013-01-01

    Highlights: ► An overview of the Port Integration hardware for tenant system hosting inside ITER diagnostics ports is given. ► The main challenges for diagnostic port integration engineering are presented. ► The actions taken for a common modular approach and a coordinated design are detailed. -- Abstract: ITER will have a set of 45 diagnostics to ensure controlled operation. Many of them are integrated in the ITER ports. This paper addresses the integration process of the diagnostic systems and the approach taken to enable coordinated progress. An overview of the Port Integration hardware introduces the various structures needed for hosting tenant systems inside ITER diagnostics ports. The responsibilities of the different parties involved (ITER Organization and the Domestic Agencies) are outlined. The main challenges for diagnostic port integration engineering are summarized. The plan for a common approach to design and manufacture of the supporting structures, in particular the Port Plug is detailed. A coordinated design including common components and a common approach for neutronic analyses is proposed. One particular port, the equatorial port 11, is used to illustrate the approach

  19. An integrated port camera and display system for laparoscopy.

    Science.gov (United States)

    Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E

    2010-05-01

    In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.

  20. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  1. Assessing Port Governance, Devolution and Terminal Performance in Nigeria

    Directory of Open Access Journals (Sweden)

    D. E. Onwuegbuchunam

    2018-02-01

    Full Text Available Concerns about performance and efficiency in port terminals led many national governments to embark on port reforms. The Federal government of Nigeria, for example, adopted the Landlord port model which brought about concessioning of port terminals to private operators. Despite high investments in terminal facilities by the private terminal operators, there are still complaints about level of service offered to port users. This paper applied key performance indicator metrics and parameters of queuing model in assessing performance of Nigeria’s concessioned port terminals. Data for the study were obtained from terminal level records of cargo and ship handling activities for years 2000 to 2015. Major findings indicate that cargo and vessel throughputs improved after the reforms in the six ports examined. However, much variability was observed in trends in ships’ turnround times across all ports after the concession policy implementation. Additional results from the queuing model analysis suggest that the high ships turnround times observed in some ports are associated to delays in ship operation at the berths. The paper recommends that policy interventions be focused on ship operations at the berths as a step in improving service level in the port terminals.

  2. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  3. Ecological risk assessments for the baseline condition for the Port Hope and Port Granby Projects

    International Nuclear Information System (INIS)

    Hart, D.R.; Kleb, H.

    2006-01-01

    Baseline ecological risk assessments were completed in and around the areas where cleanup of low-level radioactive waste (LLRW) and marginally contaminated soil (MCS) is planned under the Port Hope Area Initiative (PHAI). Both aquatic and terrestrial environments were assessed, in the vicinity of the proposed waste management facilities near Welcome and Port Granby, in locations potentially influenced by LLRW and MCS that will be cleaned up in future, and in reference locations that are not potentially influenced. The calculated doses and risk quotients suggest potential radiation effects for pre-cleanup benthic invertebrates in Port Hope Harbour, for any ducks feeding exclusively in this area, and for soil invertebrates in some other waste sites. In addition, risk quotients suggest potential baseline effects from some elements, particularly uranium and arsenic, in localized areas that are influenced by LLRW and MCS. (author)

  4. Analysis of laparoscopic port site complications: A descriptive study

    Directory of Open Access Journals (Sweden)

    Somu Karthik

    2013-01-01

    Full Text Available Context: The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. Aims: To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. Settings and Design: Prospective descriptive study. Materials and Methods: In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. Statistical Analysis Used: Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. Results: Of the 570 patients undergoing laparoscopic surgery, 17 (3% had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI was the most frequent (n = 10, 1.8%, followed by port site bleeding (n = 4, 0.7%, omentum-related complications (n = 2; 0.35%, and port site metastasis (n = 1, 0.175%. Conclusions: Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit.

  5. Analysis of laparoscopic port site complications: A descriptive study

    Science.gov (United States)

    Karthik, Somu; Augustine, Alfred Joseph; Shibumon, Mundunadackal Madhavan; Pai, Manohar Varadaraya

    2013-01-01

    CONTEXT: The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. AIMS: To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. SETTINGS AND DESIGN: Prospective descriptive study. MATERIALS AND METHODS: In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. STATISTICAL ANALYSIS USED: Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. RESULTS: Of the 570 patients undergoing laparoscopic surgery, 17 (3%) had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI) was the most frequent (n = 10, 1.8%), followed by port site bleeding (n = 4, 0.7%), omentum-related complications (n = 2; 0.35%), and port site metastasis (n = 1, 0.175%). CONCLUSIONS: Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit. PMID:23741110

  6. EVALUATING THE COMPETITION DYNAMICS OF CONTAINER PORTS IN THE NORTH ADRIATIC

    OpenAIRE

    Twrdy, Elen; Batista, Milan

    2014-01-01

    World trade has changed in the last decade and the container traffic flows are oriented towards several parts of the European continent. A European container port system is not a homogenous set of ports, but is established of several large ports (Rotterdam, Hamburg, Algeciras...) and a large number of medium- and small-sized ports. North Adriatic (NA) ports belong to this category of ports and in this paper we have analysed the container flows and the throughput attained in these ports.

  7. An analysis of the development of port operation in Da Nang Port, Vietnam

    Science.gov (United States)

    Nguyen, T. D. H.; Cools, M.

    2018-04-01

    This paper presents the current operating status in Da Nang Port, Vietnam in the period 2012-2016. The port operation had positive changes that were reflected by a significant increase in total throughputs, especially containerized cargo volumes. Classical decomposition techniques are used to find trend-cycle and seasonal components of monthly throughput flows. Appropriate predictive models of different kinds of throughputs are proposed. Finally, a development strategy towards containerization and investment policies in facilities, equipment, and infrastructure are suggested based on the predictive results.

  8. Ports, policies and interventions in ports in Portugal - 20th Century

    OpenAIRE

    Dias, Emílio Brògueira; Alves, Jorge Fernandes

    2010-01-01

    Ce texte, inspiré des données issues des travaux des deux auteurs, aborde, de manière synthétique, les grandes lignes des transformations portuaires au Portugal, à travers un panorama des différents ports et de leur évolution. Cet exposé se focalise sur les exemples les plus significatifs que sont les ports de Leixões, Aveiro, Lisbonne, Setubal et Sines. This text, based on the data used in previous works by the authors, seeks to assess briefly, the main lines of transformations in Portuga...

  9. Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

    International Nuclear Information System (INIS)

    Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles

    2016-01-01

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

  10. Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer.

    Science.gov (United States)

    Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles

    2016-01-01

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic-based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  11. Analyzing Growth Opportunity of Port from the Resource-based Perspective The Case of Port of Tanjung Pelepas Malaysia

    Directory of Open Access Journals (Sweden)

    Muhammad Subhan

    2008-09-01

    Full Text Available Capturing growth opportunity has become a major integral activity of any port to sustain growth and competitive advantage. One of the famous strategies in leveraging sustainable growth and competitive advantage is the resource-based theory application into port strategic management, viewing resources of the port (internal and external and its capabilities as the sources for achieving competitive advantage. In this study, we attempt to identify, exploit, and analyze growth opportunity of a Malaysian port from the perspective of the theory. We analyze the port’s resources in terms of values, uniqueness, inimitability, durability, and substitutability. The result is then compared with its rival ports in the region. This study recognizes that the port has successfully identified and exploited its resources for capturing growth opportunity and competing with other ports in the region. We perceive that the port will sustain its growth and competitive advantage as a major port in the region based on its current performance and rivalry circumstances. This study signifies that the higher the level to which resource-based theory of competitive advantage is applied, the higher and longer the growth and competitive advantage will be achieved by the port.

  12. Spatial Determinants of Import Traffic Distribution At Port Harcourt (Nigeria

    Directory of Open Access Journals (Sweden)

    Soddy I. Inyang

    2013-07-01

    Full Text Available This paper highlights the result of a study carried out to examine the Geographic determinants of import traffic distribution at the Port Harcourt Port. A substantial aspect of the study involved building a regression model to estimate import distribution from the Port. The import function was specified in log-linear form. The adequacy of the model was then tested; this, involved statistical experiments to obtain the R-squared, as well as t and f values. Further test on the adequacy of the nwdel was conducted through diagnostic exercises designed to check for inulticollinedrity and heteroscedasticity, in the data used. Results obtained show that road distance and manufacturing industries are significant Geographic determinants of import Cargo distribution at the study Port. It is therefore important to lake the two variables into account in any policy or planning exercise at Port Harcourt Port.

  13. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  14. Rotating positron tomographs revisited

    International Nuclear Information System (INIS)

    Townsend, D.; Defrise, M.; Geissbuhler, A.

    1994-01-01

    We have compared the performance of a PET scanner comprising two rotating arrays of detectors with that of the more conventional stationary-ring design. The same total number of detectors was used in each, and neither scanner had septa. For brain imaging, we find that the noise-equivalent count rate is greater for the rotating arrays by a factor of two. Rotating arrays have a sensitivity profile that peaks in the centre of the field of view, both axially and transaxially. In the transaxial plane, this effect offsets to a certain extent the decrease in the number of photons detected towards the centre of the brain due to self-absorption. We have also compared the performance of a rotating scanner to that of a full-ring scanner with the same number of rings. We find that a full-ring scanner with an axial extent of 16.2 cm (24 rings) is a factor of 3.5 more sensitive than a rotating scanner with 40% of the detectors and the same axial extent. (Author)

  15. Repair of traumatic tricuspid insufficiency via minimally invasive port access.

    Science.gov (United States)

    Kasahara, Hirofumi; Kudo, Mikihiko; Kawajiri, Hiroyuki; Yozu, Ryohei

    2010-04-01

    We report on a successful tricuspid valve plasty using port-access minimally invasive cardiac surgery (MICS) for severe traumatic tricuspid insufficiency caused by blunt chest trauma suffered 15 years previously. A combination repair procedure, consisting of cleft closures, plication of the anteroseptal commissure, and ring annuloplasty, was necessary to achieve valve competence and proved possible via port access without difficulty. Port-access MICS is an alternative approach for tricuspid valve surgery.

  16. A Mixed Integer Programming for Port Anzali Development Plan

    OpenAIRE

    Mahdieh Allahviranloo

    2009-01-01

    This paper introduces a mixed integer programming model to find the optimum development plan for port Anzali. The model minimizes total system costs taking into account both port infrastructure costs and shipping costs. Due to the multipurpose function of the port, the model consists of 1020 decision variables and 2490 constraints. Results of the model determine the optimum number of berths that should be constructed in each period and for each type of cargo. In addition to, the results of se...

  17. Intracorporeal hybrid single port vs conventional laparoscopic appendectomy in children

    Directory of Open Access Journals (Sweden)

    Paul Anthony Karam

    2016-12-01

    Full Text Available Transumbilical laparoscopic assisted appendectomy combines laparoscopic single port dissection with open appendectomy after exteriorization of the appendix through the port site. Compared to the conventional three-port approach, this technique provides an alternative with excellent cosmetic outcome. We developed a safe and effective technique to perform an intracorporeal single port appendectomy, using the same laparoscope employed in the extracorporeal procedure. Retrospective review of 71 consecutively performed intracorporeal single port appendectomies and 30 conventional three-port appendectomies in children 6 to 17 years of age. A straight 10-mm Storz telescope with inbuilt 6 mm working channel is used to dissect the appendix, combined with one port-less 2.3 mm percutaneous grasper. Polymer WECK® hem-o-lock® clips are applied to seal the base of the appendix and the appendiceal vessels. No intraoperative complications were reported with the hybrid intracorporeal single port appendectomy or three-port appendectomy. There were two post-operative complications in the group treated with the single port hybrid technique: one intra-abdominal abscess and one surgical site infection. Groups did not differ in age, weight, and types of appendicitis. Operative times were shorter for the hybrid technique (70 vs 79 minutes but did not differ significantly (P=0.19. This modified technique to a previously described single port extracorporeal appendectomy is easy to master and implement. It provides exposure similar to a three-port laparoscopic appendectomy, while maintaining virtually scarless results and potentially reduces the risk for surgical site infections compared to the extracorporeal technique.

  18. Irrigation port hydration in phacoemulsification surgery

    Directory of Open Access Journals (Sweden)

    Suzuki H

    2018-01-01

    Full Text Available Hisaharu Suzuki,1 Yoichiro Masuda,2 Yuki Hamajima,1 Hiroshi Takahashi3 1Department of Ophthalmology, Nippon Medical School Musashikosugi Hospital, Kawasaki City, Kanagawa, 2Department of Ophthalmology, The Jikei University, Katsushika Medical Center, Tokyo, 3Department of Ophthalmology, Nippon Medical School, Tokyo, Japan Background: In most cases, hydration is performed by water injection into the stromal tissue with a needle. The technique is simple, however it is sometimes troublesome.Purpose: We describe a simple technique for hydrating the corneal stroma in cataract surgery using an irrigation port.Patients and methods: The technique began by pushing the irrigation port against the corneal stroma for a few seconds during phacoemulsification, which generated edema in the corneal incision that subsequently prevented leakage. This procedure is called the hydration using irrigation port (HYUIP technique. A total of 60 eyes were randomized and placed in two groups, 30 eyes underwent surgeries using the HYUIP technique (HYUIP group and 30 eyes underwent surgeries without the HYUIP technique (control. The three points evaluated during each surgery included 1 the occurrence of anterior chamber collapse during the pulling out of the I/A tip after inserting the intraocular lens, 2 the need for conventional hydration, and 3 watertight completion at the end stage of surgery.Results: The anterior chamber collapse and the need for conventional hydration were significantly smaller in the HYUIP group compared to the control group. Regarding the self-sealing completion, no significant difference was observed between the two groups.Conclusion: The HYUIP technique is an effective method for creating self-sealing wound. In addition, this technique helps to prevent anterior chamber collapse. Keywords: cataract surgery, hydration, irrigation and aspiration, phacoemulsification, wound, self-sealing 

  19. Port and EGR Mass Flow Sensors

    DEFF Research Database (Denmark)

    Hendricks, Elbert

    1998-01-01

    The note documents briefly work done on what is thought to be a new method of measurement of the pulsating flow in the intake port ot and SI engine and in the EGR returen line. The work reviewed has been carried out in close cooperation with Civ. Ing. Michael Føns, Civ. Ing. Christian Jepsen, the......, the author (IAU) and Spencer C. Sorenson (ET). The theory which decribes in detail the overall dynamic chracteristics of the sensor was developed at IAU and ET, DTU....

  20. Compressor ported shroud for foil bearing cooling

    Science.gov (United States)

    Elpern, David G [Los Angeles, CA; McCabe, Niall [Torrance, CA; Gee, Mark [South Pasadena, CA

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  1. The optical rotator

    DEFF Research Database (Denmark)

    Tandrup, T; Gundersen, Hans Jørgen Gottlieb; Jensen, Eva B. Vedel

    1997-01-01

    further discuss the methods derived from this principle and present two new local volume estimators. The optical rotator benefits from information obtained in all three dimensions in thick sections but avoids over-/ underprojection problems at the extremes of the cell. Using computer-assisted microscopes......The optical rotator is an unbiased, local stereological principle for estimation of cell volume and cell surface area in thick, transparent slabs, The underlying principle was first described in 1993 by Kieu Jensen (T. Microsc. 170, 45-51) who also derived an estimator of length, In this study we...... the extra measurements demand minimal extra effort and make this estimator even more efficient when it comes to estimation of individual cell size than many of the previous local estimators, We demonstrate the principle of the optical rotator in an example (the cells in the dorsal root ganglion of the rat...

  2. Vibrations of rotating machinery

    CERN Document Server

    Matsushita, Osami; Kanki, Hiroshi; Kobayashi, Masao; Keogh, Patrick

    2017-01-01

    This book opens with an explanation of the vibrations of a single degree-of-freedom (dof) system for all beginners. Subsequently, vibration analysis of multi-dof systems is explained by modal analysis. Mode synthesis modeling is then introduced for system reduction, which aids understanding in a simplified manner of how complicated rotors behave. Rotor balancing techniques are offered for rigid and flexible rotors through several examples. Consideration of gyroscopic influences on the rotordynamics is then provided and vibration evaluation of a rotor-bearing system is emphasized in terms of forward and backward whirl rotor motions through eigenvalue (natural frequency and damping ratio) analysis. In addition to these rotordynamics concerning rotating shaft vibration measured in a stationary reference frame, blade vibrations are analyzed with Coriolis forces expressed in a rotating reference frame. Other phenomena that may be assessed in stationary and rotating reference frames include stability characteristic...

  3. Three port converters used as interface in photovoltaic energy systems

    Directory of Open Access Journals (Sweden)

    Sarab Al-Chlaihawi

    2018-04-01

    Full Text Available The aim of this paper is to derive and study a full-bridge three-port converter. Based on the standard design of full-bridge converter, we have modeled and derived a three port converter. The three port converter can be used in renewable energy scenarios, such as solar cells or wind turbines connected to the input port. The input can be taken from two-ports simultaneously or from one port at a time. In order to balance the power mismatch between the input port and load port, the batteries are attached to the third port, to ensure there are no discrepancies in the power generated at the input and power demand at the load. In order to ensure isolation and reduced voltage stress on the switches, a high frequency transformer is also used in the design. The overall design contains four switches, and four diodes. MOSFETs are the strongest candidate for the switches owing to their high switching speed, lower losses and high resistance to higher voltage. Moreover, a buck-boost structure is modeled in order to ensure that it can work for a wide variety of different applications by adjusting the duty cycle of the switches properly. To minimize the switching losses in the converter, Zero-Voltage Switching (ZVS is also achievable in the modeled system.

  4. Soil contamination issues at U.S. ports

    International Nuclear Information System (INIS)

    Rice, D.W.; Hagner, D.

    1991-01-01

    This paper reports that seven large and medium size west coast ports were surveyed during August 1990 to determine their involvement with hydrocarbon contaminated soils and activities associated with the characterization and remediation of these soils. All ports surveyed indicated that hey have hydrocarbon contaminated soil problems. Although other west coast ports do not have the scale of petroleum transfer and storage facilities that the Prot of Los Angeles has, all ports had tenants with bulk oil or fuel storage in aboveground tanks and were undertaking characterization and remediation work. Hydrocarbon contaminated soil problems were associated with these facilities or with decommissioned facilities of this type

  5. The Aggregate Planning For Trucking Operation in Cikarang Dry Port

    Directory of Open Access Journals (Sweden)

    Dwi Puspita Sari Utami

    2015-06-01

    Full Text Available Abstract. Cikarang Dry Port currently is the only dry port in Indonesia. This Dry Port has a role to connect or extend the Sea Port to the industrial areas located far from Sea Port. Thus, it creates a value added and also reduce costs. One of the operations done in Cikarang Dry Port is trucking operation. This research aims to examine the planning of 2014 trucking activity in Cikarang Dry Port to determine the right number of the truck that will be best occupied to manage all demands. The analysis begins with demand forecasting by using a moving average method of 12 months or one year period in 2013 which will be used as main information to develop the plans. There are three plans developed in this research. Based on the three plans, Plan A with minimum trucking plan with subcontracting is the most profitable which gives the highest profitability of Rp. 374,984,625. Recommendation for this research is using the current minimum number of 39 trucks rent with additional subcontracting when the demand is exceeding the capacity, thus, Cikarang Dry Port can occupy all demands and gain more profits. Keywords: Aggregate Planning; Scheduling; Trucking Operation; Moving Average; Cikarang Dry Port

  6. The Aggregate Planning For Trucking Operation in Cikarang Dry Port

    Directory of Open Access Journals (Sweden)

    Dwi Puspita Sari Utami

    2015-07-01

    Full Text Available Abstract. Cikarang Dry Port currently is the only dry port in Indonesia. This Dry Port has a role to connect or extend the Sea Port to the industrial areas located far from Sea Port. Thus, it creates a value added and also reduce costs. One of the operations done in Cikarang Dry Port is trucking operation. This research aims to examine the planning of 2014 trucking activity in Cikarang Dry Port to determine the right number of the truck that will be best occupied to manage all demands. The analysis begins with demand forecasting by using a moving average method of 12 months or one year period in 2013 which will be used as main information to develop the plans. There are three plans developed in this research. Based on the three plans, Plan A with minimum trucking plan with subcontracting is the most profitable which gives the highest profitability of Rp. 374,984,625. Recommendation for this research is using the current minimum number of 39 trucks rent with additional subcontracting when the demand is exceeding the capacity, thus, Cikarang Dry Port can occupy all demands and gain more profits.Keywords: Aggregate Planning; Scheduling; Trucking Operation; Moving Average; Cikarang Dry Port

  7. Development of the alternate entry port for the ATF

    International Nuclear Information System (INIS)

    Parsa, Z.

    1993-05-01

    We discussed a second entry port for the Accelerator Test Facility (ATF) injection system at Brookhaven National Laboratory, which consists of a photocathode rf gun and a straight - ahead beamline directly into the 50 MeV linac. The proposed second entry port should improve the beam quality and lower the emittance needed for FEL (Free Electron Laser), and laser - acceleration experiments. A discussion on the laser driven high brightness photoelectrons through the primary entry port (a low energy 180 degrees achromatic double bend transport line) now in operation, and a beam analysis for the proposed secondary port is also given

  8. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.; Siegel, Randall L.; Biswal, Rajiv; Gribbin, Christopher E.; Tokarz, Robert

    2000-01-01

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. A combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant

  9. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  10. Optimisation of ported yield of hemispherical ported microparticles for soft tissue augmentation

    CSIR Research Space (South Africa)

    Barnard, A

    2011-05-01

    Full Text Available degradation period and biocompatibility. Micro-porous particles are useful in soft-tissue bulking due to their relatively large surface area, low density and high degree of porosity. In this study, the authors have developed ported porous PCL particles...

  11. Rotating quantum states

    International Nuclear Information System (INIS)

    Ambruş, Victor E.; Winstanley, Elizabeth

    2014-01-01

    We revisit the definition of rotating thermal states for scalar and fermion fields in unbounded Minkowski space–time. For scalar fields such states are ill-defined everywhere, but for fermion fields an appropriate definition of the vacuum gives thermal states regular inside the speed-of-light surface. For a massless fermion field, we derive analytic expressions for the thermal expectation values of the fermion current and stress–energy tensor. These expressions may provide qualitative insights into the behaviour of thermal rotating states on more complex space–time geometries

  12. Rotating bubble membrane radiator

    Science.gov (United States)

    Webb, Brent J.; Coomes, Edmund P.

    1988-12-06

    A heat radiator useful for expelling waste heat from a power generating system aboard a space vehicle is disclosed. Liquid to be cooled is passed to the interior of a rotating bubble membrane radiator, where it is sprayed into the interior of the bubble. Liquid impacting upon the interior surface of the bubble is cooled and the heat radiated from the outer surface of the membrane. Cooled liquid is collected by the action of centrifical force about the equator of the rotating membrane and returned to the power system. Details regarding a complete space power system employing the radiator are given.

  13. Analyzing Growth Opportunity of Port from the Resource-based Perspective The Case of Port of Tanjung Pelepas Malaysia

    OpenAIRE

    Subhan, Muhammad; Abdul Ghani, Ahmad Bashawir

    2008-01-01

    Capturing growth opportunity has become a major integral activity of any port to sustain growth and competitive advantage. One of the famous strategies in leveraging sustainable growth and competitive advantage is the resource-based theory application into port strategic management, viewing resources of the port (internal and external) and its capabilities as the sources for achieving competitive advantage. In this study, we attempt to identify, exploit, and analyze growth opportunity of a Ma...

  14. Adding some context to port marketing: Exploring the content and measurement of market orientation in the port industry

    OpenAIRE

    Kounoupas, Evangelos; Pardali, Angeliki

    2015-01-01

    Understanding and responding to customer needs is the essence of the marketing concept and as such it has been discussed in various fields of business and economic literature. Port economics and management literature has thoroughly investigated areas such as port efficiency and effectiveness, understanding and overcoming competitive pressures and identifying the sources of potential sustainable competitive advantage. In line with this discussion, albeit with a significant time delay, port eco...

  15. An overview of San Francisco Bay PORTS

    Science.gov (United States)

    Cheng, Ralph T.; McKinnie, David; English, Chad; Smith, Richard E.

    1998-01-01

    The Physical Oceanographic Real-Time System (PORTS) provides observations of tides, tidal currents, and meteorological conditions in real-time. The San Francisco Bay PORTS (SFPORTS) is a decision support system to facilitate safe and efficient maritime commerce. In addition to real-time observations, SFPORTS includes a nowcast numerical model forming a San Francisco Bay marine nowcast system. SFPORTS data and nowcast numerical model results are made available to users through the World Wide Web (WWW). A brief overview of SFPORTS is presented, from the data flow originated at instrument sensors to final results delivered to end users on the WWW. A user-friendly interface for SFPORTS has been designed and implemented. Appropriate field data analysis, nowcast procedures, design and generation of graphics for WWW display of field data and nowcast results are presented and discussed. Furthermore, SFPORTS is designed to support hazardous materials spill prevention and response, and to serve as resources to scientists studying the health of San Francisco Bay ecosystem. The success (or failure) of the SFPORTS to serve the intended user community is determined by the effectiveness of the user interface.

  16. Strategic and Operational Plan Implementation of Seaports (Utilization Jeddah Port

    Directory of Open Access Journals (Sweden)

    Akram Elentably

    2015-12-01

    Full Text Available The Port of Jeddah (Port released the initial version of this Strategic Plan in 2006. It was developed by Port staff, along with input, as a five-year rolling plan designed to guide the Port’s future development while keeping in mind the needs of our tenants, local community members and stakeholders, and the nation. This is the second update to the Strategic Plan since its initial release. While the Port’s overarching principles – commitment to environmental stewardship, addressing tenant needs, goods movement, economic development, and security – have remained largely unchanged, it is important for us to adapt our strategies to meet the challenges of an ever changing local and global environment. The Port is among the world’s premier ports and is a critical hub for global trade. This prominence brings with it responsibilities and expectations for the highest possible standards for efficiency, safety and security, and environmental leadership. The Port is the nation’s busiest container port and part of the world’s busiest port complex, handling 3.7 million twenty-foot equivalent units in 2013. Global trade and goods movement is Western kingdom of Saudi Arabia’s strongest industries in terms of jobs and economic activity. The Port of Jeddah powers these industries, handling almost more than a quarter of the cargo that enters the kingdom of Saudi Arabia annually. Through the Port’s activities, a lot of jobs are created in western kingdom of Saudi Arabia and over five hundred thousand nationwide. In order to maintain our position among the world’ the kingdom of Saudi Arabia premier ports, the Port is continually addressing the demands for providing modern and efficient cargo handling terminals as well as transportation and infrastructure projects. Protecting one of the nation’s most vital economic hubs is also an ongoing challenge. Finally, promoting a sustainable “grow green” philosophy and ensuring that we are the leader

  17. Continuous Arc Rotation of the Couch Therapy for the Delivery of Accelerated Partial Breast Irradiation: A Treatment Planning Analysis

    International Nuclear Information System (INIS)

    Shaitelman, Simona F.; Kim, Leonard H.; Yan Di; Martinez, Alvaro A.; Vicini, Frank A.; Grills, Inga S.

    2011-01-01

    Purpose: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. Methods and Materials: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. Results: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. Conclusions: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.

  18. Rotations and angular momentum

    International Nuclear Information System (INIS)

    Nyborg, P.; Froyland, J.

    1979-01-01

    This paper is devoted to the analysis of rotational invariance and the properties of angular momentum in quantum mechanics. In particular, the problem of addition of angular momenta is treated in detail, and tables of Clebsch-Gordan coefficients are included

  19. Negative Rotation Cinch Strap.

    Science.gov (United States)

    This project discloses an improved unitary parachute torso harness, having a single fastening means, wherein an auxillary tightening strap is...attached to the groin straps of said harness. Said auxillary straps are used to prevent torso rotation or harness slippage and to prevent harness elongation

  20. A rotating string

    International Nuclear Information System (INIS)

    Jensen, B.

    1993-06-01

    The author presents a global solution of Einstein's equations which represents a rotating cosmic string with a finite coreradius. The importance of pressure for the generation of closed timelike curves outside the coreregion of such strings is clearly displayed in this model due to the simplicity of the source. 10 refs

  1. Rotator Cuff Injuries.

    Science.gov (United States)

    Connors, G. Patrick

    Many baseball players suffer from shoulder injuries related to the rotator cuff muscles. These injuries may be classified as muscular strain, tendonitis or tenosynovitis, and impingement syndrome. Treatment varies from simple rest to surgery, so it is important to be seen by a physician as soon as possible. In order to prevent these injuries, the…

  2. Rotational dynamics with Tracker

    International Nuclear Information System (INIS)

    Eadkhong, T; Danworaphong, S; Rajsadorn, R; Jannual, P

    2012-01-01

    We propose the use of Tracker, freeware for video analysis, to analyse the moment of inertia (I) of a cylindrical plate. Three experiments are performed to validate the proposed method. The first experiment is dedicated to find the linear coefficient of rotational friction (b) for our system. By omitting the effect of such friction, we derive I for a cylindrical plate rotated around its central axis from the other two experiments based on the relation between torque and angular acceleration of rotational motion and conservation of energy. Movies of the rotating plate and hung masses are recorded. As a result, we have the deviation of I from its theoretical value of 0.4% and 3.3%, respectively. Our setup is completely constructed from locally available inexpensive materials and the experimental results indicate that the system is highly reliable. This work should pave the way for those who prefer to build a similar setup from scratch at relatively low cost compared to commercial units. (paper)

  3. The Axial Curve Rotator.

    Science.gov (United States)

    Hunter, Walter M.

    This document contains detailed directions for constructing a device that mechanically produces the three-dimensional shape resulting from the rotation of any algebraic line or curve around either axis on the coordinate plant. The device was developed in response to student difficulty in visualizing, and thus grasping the mathematical principles…

  4. Can planetary nebulae rotate

    International Nuclear Information System (INIS)

    Grinin, V.P.

    1982-01-01

    It is shown that the inclination of spectral lines observed in a number of planetary nebulae when the spectrograph slit is placed along the major axis, which is presently ascribed to nonuniform expansion of the shells, actually may be due to rotation of the nebulae about their minor axes, as Campbell and Moore have suggested in their reports. It is assumed that the rotation of the central star (or, if the core is a binary system, circular motions of gas along quasi-Keplerian orbits) serves as the source of the original rotation of a protoplanetary nebula. The mechanism providing for strengthening of the original rotation in the process of expansion of the shell is the tangential pressure of L/sub α/ radiation due to the anisotropic properties of the medium and radiation field. The dynamic effect produced by them is evidently greatest in the epoch when the optical depth of the nebula in the L/sub c/ continuum becomes on the order of unity in the course of its expansion

  5. SU-F-J-191: Dosimetric Evaluation of a Left Chestwall Patient Treated with a Compact Proton Pencil Beam Gantry Utilizing Daily Setup CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Maynard, M; Chen, K; Rosen, L; Wu, H [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2016-06-15

    Purpose: To evaluate the robustness of the gradient technique for treating a multi-isocenter left chest wall patient with a compact proton pencil beam gantry. Both CBCT and stereoscopic imaging are used to facilitate daily treatment setup. Methods: To treat the elongated chest wall planning target volume (PTV) with the compact PBS system, a 28 fraction (5040 CcGE) treatment plan was created using two fields with gradient matching technique. Daily table shifts between treatment field isocenters were obtained from the record and verify system for each treatment fraction. Copies of the initial treatment plan were made for each fraction and the field isocenter coordinates for each plan copy were adjusted to reflect daily table shifts. Doses were re-calculated for each fraction, summed, and compared against the initial plan. Results: The table shifts (average and range) were 2.2 (−5.1–+3.9), 3.0 (−6.0–+4.0) and 3.0 (−10.1–+1.9) millimeters in the anterior-posterior, superior-inferior and right-left directions, respectively. Dose difference to the PTV, heart and ipsilateral lung were evaluated. The percentage of the PTV receiving the prescription dose decreased from 94.6% to 89.1%. The D95 of the PTV increased from 99.6% to 99.9%. The maximum dose in PTV increased from 106.6% to 109.2% and V105 increased from 1.0% to 16.5%. The V20 of the ipsilateral lung increased from 18.5% to 21.0%. The mean heart dose difference was negligible. Conclusion: Observed dose differences to lung and heart tissues due to daily setup variations remained acceptably low while maintaining sufficient dose coverage to the PTV. This initial case study demonstrates the robustness of the gradient technique to treat a large target, multi-isocenter plan with a compact proton pencil beam gantry equipped with CBCT and stereoscopic imaging modalities.

  6. Environmental reform of West and Central Africa ports

    NARCIS (Netherlands)

    Barnes-Dabban, Harry; Koppen, Van Kris; Mol, Arthur

    2017-01-01

    West and Central Africa ports have historically not paid much attention to environmental issues. In the past decade, however, environmental concerns are beginning to emerge with pockets of innovative responses to environmental risks as the ports undergo institutional and infrastructural reform –

  7. 33 CFR 80.1440 - Port Allen, Kauai, HI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Port Allen, Kauai, HI. 80.1440 Section 80.1440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES COLREGS DEMARCATION LINES Pacific Islands § 80.1440 Port Allen, Kauai, HI. A line drawn from...

  8. Port supply chain integration : analyzing biofuel supply chains

    NARCIS (Netherlands)

    Stevens, Leonie C. E.; Vis, Iris F. A.

    2016-01-01

    This paper focuses on port supply chain integration to strengthen operational and business performance. We provide a structured and comprehensive method to enable port supply chain integration and demonstrate its applicability to the biofuel supply chain. We define the value proposition, role,

  9. 7 CFR 319.55-3 - Ports of entry.

    Science.gov (United States)

    2010-01-01

    ... through Mexican border ports and such other ports as may later be approved by the Plant Protection and... Plant Protection and Quarantine Programs. (c) Pending development of adequate treating facilities in... Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE...

  10. 33 CFR 110.155 - Port of New York.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Port of New York. 110.155 Section... ANCHORAGE REGULATIONS Anchorage Grounds § 110.155 Port of New York. (a) Long Island Sound—(1) Anchorage No... northwest corner of the crib icebreaker north of the New York Central Railroad Company drawbridge across...

  11. 75 FR 22323 - Anchorage Regulations; Port of New York

    Science.gov (United States)

    2010-04-28

    ...-AA01 Anchorage Regulations; Port of New York AGENCY: Coast Guard, DHS. ACTION: Supplemental notice of..., Coast Guard Sector New York, Waterways Management Division; telephone 718-354-4195, e-mail Jeff.M.Yunker... Purpose The Hudson River Pilots Association, through the Port of New York/ New Jersey Harbor Safety...

  12. Exploration of an ancient port: Elephanta Island (Bombay)

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, S.R.; Gaur, A; Tripati, S.

    of amphora sherds were recovered from the site. Morabandar was busy port during 4th-5th century AD as a large number of coins of this period have been found. While Shetbandar served as port till modern period. Onshore and inter tidal zone explorations brought...

  13. Treatment of acute appendicitis with one-port transumbilical ...

    African Journals Online (AJOL)

    Background: Laparoscopic appendectomy is a feasible and safe alternative to open appendectomy for uncomplicated appendicitis. In the past decade several laparoscopic procedures have been described using one or more ports. We report our experience in treating acute appendicitis with one-port transumbilical ...

  14. Spatio-Temporal Variations in Urban Vehicular Emission in Port ...

    African Journals Online (AJOL)

    vThe increasing high volume of road traffic and congestion is a fundamental issue in Port Harcourt metropolis. The degradation of air quality arising from these is another serious dimension of the problem. This study estimated the emissions of pollutants from vehicles during traffic peak periods within parts of the city of Port ...

  15. Sustainability as a procurement criterion for port investments

    NARCIS (Netherlands)

    Broesterhuizen, E.F.M.; Vellinga, T.; Docters van Leeuwen, L.; Taneja, P.; Zwakhals, J.W.; Nijdam, M.H.

    2012-01-01

    Ports are known to be one of the most polluting sectors, and therefore provide an opportunity to reduce emission significantly. Until now, the attention has been given to reduction of emissions in transport and shipping. The scope of research must expand to include port infrastructures, which should

  16. Port-Orford-cedar—a poor risk for reforestation.

    Science.gov (United States)

    John Hunt; Edward J. Dimock

    1957-01-01

    Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murr.) Parl.) has been the most widely used introduced species in reforestation projects in western Washington and Oregon. However, as a result of two recent and unrelated occurrences, a severe early cold wave and a destructive root disease, the advisability of continued planting of Port-Orford-cedar...

  17. Model reduction of port-Hamiltonian systems as structured systems

    NARCIS (Netherlands)

    Polyuga, R.V.; Schaft, van der A.J.

    2010-01-01

    The goal of this work is to demonstrate that a specific projection-based model reduction method, which provides an H2 error bound, turns out to be applicable to port-Hamiltonian systems, preserving the port-Hamiltonian structure for the reduced order model, and, as a consequence, passivity.

  18. Malaria infection and socioeconomic status of some residents of Port ...

    African Journals Online (AJOL)

    The study investigated the prevalence of malaria and socioeconomic status of subjects in part of Port Harcourt metropolis. Following ethical clearance which was obtained from the University of Port Harcourt and the parents of the subjects who gave their written consents, blood samples were collected and analysed ...

  19. Infant feeding tube as urinary tract stent | Ekeke | Port Harcourt ...

    African Journals Online (AJOL)

    Methods: Data from the hospital records of patients who required stents at the University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria were obtained from their case notes from May 2003 to May 2006. Information extracted from these case notes included: age and sex of patient, indications for stenting, ...

  20. 3D Spatial Information Infrastructure for the Port of Rotterdam

    NARCIS (Netherlands)

    Zlatanova, S.; Beetz, J.; Boersma, A.J.; Mulder, A.; Goos, J.

    2013-01-01

    The maintenance of the complex infrastructure and facilities of Port of Rotterdam is based on large amounts of heterogeneous information. Almost all activities of the Port require spatial information about features above- and under- ground. Current information systems are department and data

  1. Perception of undergraduates of University of Port Harcourt towards ...

    African Journals Online (AJOL)

    Aim: To assess the perception of undergraduates in University of Port Harcourt towards the use of condom. Methods: A cross-sectional questionnaire survey on the knowledge and use of condom among undergraduates of University of Port Harcourt. A systematic random sampling method was employed. Data collected was ...

  2. Perception of Rape Amongst Secondary School Students In Port ...

    African Journals Online (AJOL)

    Alasia Datonye

    Department of Paediatrics and Child health, University of Port Harcourt, Teaching Hospital,. Port Harcourt, Nigeria. ABSTRACT ... questionnaire, data collected included bio data, awareness information, response and practices. ..... behaviour and experience of sexual coercion among secondary school studenta in three ...

  3. Queuing theory models used for port equipment sizing

    Science.gov (United States)

    Dragu, V.; Dinu, O.; Ruscă, A.; Burciu, Ş.; Roman, E. A.

    2017-08-01

    The significant growth of volumes and distances on road transportation led to the necessity of finding solutions to increase water transportation market share together with the handling and transfer technologies within its terminals. It is widely known that the biggest times are consumed within the transport terminals (loading/unloading/transfer) and so the necessity of constantly developing handling techniques and technologies in concordance with the goods flows size so that the total waiting time of ships within ports is reduced. Port development should be achieved by harmonizing the contradictory interests of port administration and users. Port administrators aim profit increase opposite to users that want savings by increasing consumers’ surplus. The difficulty consists in the fact that the transport demand - supply equilibrium must be realised at costs and goods quantities transiting the port in order to satisfy the interests of both parties involved. This paper presents a port equipment sizing model by using queueing theory so that the sum of costs for ships waiting operations and equipment usage would be minimum. Ship operation within the port is assimilated to a mass service waiting system in which parameters are later used to determine the main costs for ships and port equipment.

  4. 77 FR 75823 - Closing of the Port of Whitetail, MT

    Science.gov (United States)

    2012-12-26

    ... Canada Border Services Agency's (CBSA) closure of its adjacent port of entry of Big Beaver, Saskatchewan... almost all of the decrease in southbound traffic occurring after CBSA closed the port of Big Beaver to... of entry. CBP expects that any impact on the environment and any costs incurred for this purpose will...

  5. Itinerary planning: Modelling cruise lines’ lengths of stay in ports

    NARCIS (Netherlands)

    Chen, Jamie M.; Nijkamp, Peter

    Cruise tourism is a fast-growing segment of the tourism industry that generates substantial benefits to port cities. This study explores strategic aspects of cruise lines’ itinerary planning, and models the determinants of their lengths of stay in ports, based on extensive observations of network

  6. 19 CFR 146.2 - Port director as Board representative.

    Science.gov (United States)

    2010-04-01

    ...; DEPARTMENT OF THE TREASURY (CONTINUED) FOREIGN TRADE ZONES General Provisions § 146.2 Port director as Board representative. The appropriate port director shall be in charge of the zone as the representative of the Board. [T.D. 86-16, 51 FR 5049, Feb. 11, 1986, as amended by T.D. 99-27, 64 FR 13676, Mar. 22, 1999] ...

  7. Characteristics of drayage operations at the Port of Houston.

    Science.gov (United States)

    2008-09-01

    Port drayage, defined as a container truck pickup to or from a seaport terminal with both the trip : origin and destination in the same urban area, is a critical yet comparatively understudied link in the : intermodal supply chain. Because port dray ...

  8. Challenges and Strategies of Abidjan Port-Hinterland Connectivity

    Directory of Open Access Journals (Sweden)

    Gamassa Pascal Kany Prud’ome

    2017-01-01

    Full Text Available Abidjan port-hinterland is composed of three countries which include Ivory Coast, Mali and Burkina Faso. The fast economic growth of the above countries resulted to a greater demand for the foreign goods from their population, causing a congestion problem at Abidjan port. Because of this problem, the connectivity movement between the port and its hinterland has considerably slowed down. In this article a qualitative methodology is used to analyse the Abidjan port-hinterland connectivity. The constant delays of the train services, the road congestion and the lack of coordination and communication between Abidjan port and its hinterland customers are the main presented challenges. The results of this research demonstrate that the poor quality roads and railways and the lack of a new dry port in Ivory Coast greatly affects the fluidity of the Abidjan port-hinterland connectivity. This article suggests some strategies on how to solve the current challenges and will be helpful in deciding on how the Abidjan port should be developed better and improve its connectivity with its hinterland.

  9. Port Hamiltonian Formulation of Infinite Dimensional Systems I. Modeling

    NARCIS (Netherlands)

    Macchelli, Alessandro; Schaft, Arjan J. van der; Melchiorri, Claudio

    2004-01-01

    In this paper, some new results concerning the modeling of distributed parameter systems in port Hamiltonian form are presented. The classical finite dimensional port Hamiltonian formulation of a dynamical system is generalized in order to cope with the distributed parameter and multi-variable case.

  10. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  11. Two-port Laparoscopic-assisted Appendicectomy Under Local ...

    African Journals Online (AJOL)

    Journal of Surgical Technique and Case Report | Jul-Dec 2011 | Vol-3 | Issue-2. 84. Two-port Laparoscopic-assisted ... appendicectomy (LAA) using the two-port technique under local anesthesia in adults. As a pilot study we .... of failure are the reasons for avoidance of using local anesthesia for surgical procedures.

  12. 49 CFR 176.4 - Port security and safety regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Port security and safety regulations. 176.4... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY VESSEL General § 176.4 Port security and safety regulations. (a) Each carrier, master, agent, and charterer of a...

  13. An effective strategy for porting C++ applications on cell

    NARCIS (Netherlands)

    Varbanescu, A.L.; Sips, H.; Ross, K.A.; Liu, Q.; Liu, L.K.; Natsev, A.; Smith, J.R.

    2007-01-01

    In this paper we present a solution for efficient porting of sequential C++ applications on the Cell B.E. processor. We present our step-by-step approach, focusing on its generality, we provide a set of code templates and optimization guidelines to support the porting, and we include a set of

  14. 46 CFR 171.118 - Automatic ventilators and side ports.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Automatic ventilators and side ports. 171.118 Section 171.118 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY... Bulkhead or Weather Deck § 171.118 Automatic ventilators and side ports. (a) An automatic ventilator must...

  15. Very High Frequency Two-Port Characterization of Transistors

    DEFF Research Database (Denmark)

    Hertel, Jens Christian; Nour, Yasser; Jørgensen, Ivan Harald Holger

    To properly use transistors in VHF converters, they need to be characterized under similar conditions. This research presents a two-port method, using a network analyzer (NWA) with a S-port setup. The method is a one-shot method, providing fast results of the off-state parasitics of the transistors....

  16. Agent Technology supports Inter-Organizational Planning in the Port

    NARCIS (Netherlands)

    J.M. Moonen (Hans); B. van de Rakt (Bastiaan); I. Miller; J.A.E.E. van Nunen (Jo); J. van Hillegersberg (Jos)

    2005-01-01

    textabstractThe Port of Rotterdam is a key container transshipment hub for Europe. Inland container shipping is important to connect the hinterland (40% market share). Barges visit several terminals per round-trip through the Port, thus requiring a proper planning support – to avoid planning

  17. Port exteriorization appendectomy in children: An alternative to the ...

    African Journals Online (AJOL)

    Introduction Laparoscopic appendectomy is usually performed using an intracorporeal approach. The conventional procedure uses three ports. The port exteriorization appendectomy uses two trocars to perform the entire procedure and can be considered an efficient alternative to the conventional approach, especially in ...

  18. RIVERS AND PORTS IN TRANSPORT HISTORY OF CAMEROON ...

    African Journals Online (AJOL)

    Dean SPGS NAU

    importance of the ports in the development of the cities and the migration of people ... known to have developed in this region with technological .... Douala port as a case study. .... taking place. Traders came from West African coast, Greece and. France. .... global networks have not been limited to particular hubs but rather.

  19. Structure preserving port-Hamiltonian model reduction of electrical circuits

    NARCIS (Netherlands)

    Polyuga, R.; Schaft, van der A.J.; Benner, P.; Hinze, M.; Maten, ter E.J.W.

    2011-01-01

    This paper discusses model reduction of electrical circuits based on a port-Hamiltonian representation. It is shown that by the use of the Kalman decomposition an uncontrollable and/or unobservable port-Hamiltonian system is reduced to a controllable/observable system that inherits the

  20. Safety shield for vacuum/pressure chamber viewing port

    Science.gov (United States)

    Shimansky, R. A.; Spencer, R. S. (Inventor)

    1981-01-01

    Observers are protected from flying debris resulting from a failure of a vacuum or pressure chamber viewing port following an implosion or explosion by an optically clear shatter resistant safety shield which spaced apart from the viewing port on the outer surface of the chamber.